HomeMy WebLinkAboutPermit M08-076 - WESTFIELD SOUTHCENTER MALL - TORRIDTORRID 821 SOUTHCENTER MALL M08 -076 Parcel No.: 6364200010 Address: Suite No: 821 SOUTHCENTER MALL TUKW Tenant: Name: TORRID Address: 821 SOUTHCENTER MALL , TUKWILA WA Owner: Name: Address: Contact Person: Name: SHANNON HUNTER Address: 16435 N SCOTTSDALE RD STE 195 , SCOTTSDALE AZ Contractor: Name: TIMBERWOLFF CONSTRUCTION INC Address: 1659 W ARROW RTE , UPLAND CA Contractor License No: TIMBECIO21DM DESCRIPTION OF WORK: Value of Mechanical: $15,000.00 Type of Fire Protection: CityOf Tukwila WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD CA Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC -10/06 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT Fees Collected: $338.75 International Mechanical Code Edition: 2006 EQUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 0 0 0 0 0 0 0 0 * *continued on next page ** M08 -076 Permit Number: M08 -076 Issue Date: 06/05/2008 Permit Expires On: 12/02/2008 Phone: Phone: 480 998 -4200 Phone: 909 949 -0380 Expiration Date: 03/08/2010 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 06 -05 -2008 Permit Center Authorized Signature: Print Name: (7 _,Q7c177 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: MO8 -076 Issue Date: 06/05/2008 Permit Expires On: 12/02/2008 (A)4j1t <-_ - P - 21 Date: (9 ‘- S C I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perfo ce of • .. I am authorized to sign and obtain this mechanical permit. Signatur / — /.o�l� Date: 6 ' S. oe This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC-10/06 M08 -076 Printed: 06-05 -2008 Parcel No.: 6364200010 Address: 821 SOUTHCENTER MALL TUKW Suite No: Tenant: TORRID 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 11: ** *FIRE DEPARTMENT CONDITIONS * ** doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 5: Readily accessible access to roof mounted equipment is required. PERMIT CONDITIONS Permit Number: M08 -076 Status: ISSUED Applied Date: 03/12/2008 Issue Date: 06/05/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 13: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 14: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 15: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) M08 -076 Printed: 06 -05 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 17: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 18: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 19: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 20: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 21: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 22: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * * continued on next page ** M08 -076 Printed: 06-05 -2008 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doc: Cond -10/06 • o City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.ci.tukwila.wa.us Date: ‘'S . 6e M08 -076 Printed: 06 -05 -2008 SITE LOCATION Site Address: Tenant Name: Company Name: Mailing Address: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** �11.6,011ei— A14 // 7'a D Property Owners Name: W€//e Mailing Address: / 40 / & Mid — / / ,1I rime" (mss 17 /� C/Q- City r CONTACT PERSON - who do we contact when your permit is ready to be issued Name: ‘ 5114 y. h all u 1.71t Mailing Address: 44.3s W S /0 #i Ids /9 r E -Mail Address : 4ni , 4 h194191 . l'OY�� GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: City Day Telephone: Fax Number: Expiration Date: Contact Person: E -Mail Address: Contractor Registration Number: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Contact Person:_ Y " E -Mail Address: Mi. (illt hci a Building Permit No. Mechanical Permit No. Plumbing /Gas Permit No. Public Works Permit No. Project No. (For office use only) 1)0i - t 9 22- 0 PGN� - OA° King Co Assessor's Tax No.: �G Q3Q[) 90 a 3 Suite Number: S'3/0 Floor: ' New Tenant: RI Yes ❑ .. No State Day Telephone: 4'84 PAR • City State Zip Fax Number: 00 State Zip Zip City Day Telephone: 7 -948 4c7.) Fax Number: 7b S Z ip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: Contact Person: T 1'ii 4k rS / 1 44 wed Q:\Applications'Fonns- Applications On Line 3 -2006 - Permit Application.doc Revised: 9 -2006 bh E -Mail Address: m% ed✓r '? /lee r 7 aS - City State Zip Day Telephone: *I 7-0-,283-8- - 0 -,283 8 - Fax Number: 8/ -2 /r 87// Page 1 of 6 BUILDING PERMIT INFOATION - 206 -431 -3670 Valuation of Project (contractor's bid price): $_ 11.900 00 Scope of Work (please provide detailed information): " i„ ice %IA 1"/I 4014 I JfproVen on)-- /die tial At Will there be new rack storage? ❑ Yes Q:MpplicationsTorms- Applications On Linel3 -2006 - Permit Application.doc Revised: 9 -2006 bb Existi g Building Valu tion: $ Ar No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 1.8 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or, her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes attach list of materials and storage locations on a separate 8 -1/2 "x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC l �/)(I �0 �13 2 Floor 3 Floor Floors thru Basement Accessory Structure' Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFOATION - 206 -431 -3670 Valuation of Project (contractor's bid price): $_ 11.900 00 Scope of Work (please provide detailed information): " i„ ice %IA 1"/I 4014 I JfproVen on)-- /die tial At Will there be new rack storage? ❑ Yes Q:MpplicationsTorms- Applications On Linel3 -2006 - Permit Application.doc Revised: 9 -2006 bb Existi g Building Valu tion: $ Ar No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 1.8 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or, her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes attach list of materials and storage locations on a separate 8 -1/2 "x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 Unit Type: Qty , Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty / Furnace <100K BTU ! Air CFM Handlin Unit >10,000 / Fire Damper 7 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler ! Diffuser A. 3 -15 HP /500,000 BTU Floor Furnace / Ventilation Fan Connected to Single Duct ' Thermostat / 15-30 HP /1,000,000 BTU / Mounted 11 /Floor Mounted Heater / Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU / / Appliance Vent / Hood and Duct Emergency Generator 7 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM I Incinerator — Command MECHANICAL PERMIT INFORMATION - 206 - 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: 1 D $9 "4?4-4 Valuation of Mechanical work (contractor's bid price): $ /6 - l Scope of Work (please provide detailed information): /kit 1J -f (�Il ( 14/L r—k rigs i`giq k 44 - - 4-L ,l�e K4 s 4 Se 1 v F Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New ...X Replacement .... El Fuel Type: Electric Gas .... Other: Indicate type of mechanical work being installed and the quantity below: Q:Wpplications\Fomts- Applications On Linel3.2006 - Permit Application.doc Revised: 9 -2006 bit Page 4 of 6 k PUBLIC WORKS PERMIT INFORMATION - 206 -433 -0179 Scope of Work (please provide detailed information): Call before you Dig: 1- 800 -424 -5555 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑...Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate ❑ .., er Availability Provided Septic System: ❑ On -site Septic System — For on -site septi stem, provide 2 copies of a current septic d • gn approved by King County Health Department. Submitted with Application (mark boxes which ,t t 1 ❑ ...Civil Plans (Maximum Paper Size — 22" x 3 ❑ ...Technical Information Report (Storm Drainage) ❑ .. Geote ical Report ❑...Traffic Impact. Analysis ❑ ...Bond ❑ .. Insurance ❑ .. Ease nt(s) ❑ .. Ma' enance Agreement(s) ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way ❑ ...Permanent Water Meter ❑ ...Temporary Water Met ize .. ❑ ...Water Only Meter S' ❑ ...Sewer Main Exter . on Public ❑ ...Water Main Ex sion Public Q :ApplicationsWam,s- Application On Linet3 -2006 - Permit Application.doc Revised: 9 -2006 bh ❑... Va1Vue ❑ .. Renton ❑ ...Total Cut ❑ ...Total Fill ❑ ...Sanitary Side Sewer ■ . Abandon Septic Tank ❑ ...Cap or Remove Utilities JI .. Curb Cut ❑ ...Frontage Improvements i ❑ .. Pavement Cut ❑ ...Traffic Control ❑ .. Looped Fire Line ❑ ...Backflow Prevention - Fire Protec ,'gin Irrigatio Dome-'c Water cubic yards cubic yards WO # WO # WO # Private Private ❑ .. Highline ❑ .. Renton ❑ ..: -attle .. Right -of -way Use - Profit for less than 72 hours ❑ .. Right -of -way Use — Potential Disturbance ❑ .. ork in Flood Zone ❑ .. St Drainage ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑... Deduct Water Meter Size FINANCE INFORMATION Fire Line Size at Property Line ❑ ...Water ❑ ...S ewer ❑ ...Sewage Treatment - Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: Number of Public Fire Hydrant(s) City State Zip Day Telephone: City State Zip Page 3 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN OR AUTHORIZED AGENT: Signature: Print Name: Mailing Address: ittg/I______Teg2th4 41 Date Application Accepted: 0 Q:\ApplicationsWonns- Applications On Line13 -2006 - Permit Application.doc Revised: 9 -2006 bh Date Application Expires: thl I o� Date: 2'�� -a 8' Day Tele hone: 7i'8-9it�d 9s__ so y ,9Z wry City / State Zip Staff Initials l� Page 6 of 6 i Fixture Type: Qty Fixture Type: • ,ti , ,� Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) ash fountain Gas piping outlets Bidet Food -waste grinder, commercial //// Z Rey tor, indirect was 7 Clothes washer, domestic Floor drain I Sinks Dental unit, cuspidor Shower, single heal'a ap / Urinals '' Dishwasher, domestic, with independent drain Lavatory Water Cl i t Building sewer or trailer park sewer Rain water s : tern — per drain (insi. ' building) /•• }/ Water heater': d/or vent Additional medical gas inlets /outlets —.six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair '. . Iteration of water pipin d/or water treating equ ..ment Repair or altera '+ of drainage or ven ,. piping Medical gas piping system serving one to five inlets /outlets for specific gas PLUMBING AND GAS PIPING PERMIT INFORMATION - 206 -431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Valuation of Plumbing work (con . . tor's bid price): $ Valuation of Gas Piping work (contra r's bid price): $ Scope of Work (please provide detailed ormation): Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Indicate type of plumbing fixtures and/or gas piping outlets bei Q: Wpplications\Forms.Applications On Linel3.2006 - Permit Application.doc Revised: 9 -2006 bh .00 0 P c Sh Expiration Date: Sewer: (/ X Q/7;&/ y � lied and the quantity below: Page 5 of 6 Parcel No.: 6364200010 Permit Number: M08 -076 Address: 821 SOUTHCENTER MALL TUKW Status: ISSUED Suite No: Applied Date: 03/12/2008 Applicant: TORRID Issue Date: 06/05/2008 Receipt No.: R08 -03476 Payment Amount: $60.00 Initials: JEM Payment Date: 10/08/2008 03:05 PM User ID: 1165 Balance: $0.00 Payee: BILL MOE TRANSACTION LIST: Type Method Descriptio Amount ACCOUNT ITEM LIST: Description doc: Receiot -06 Payment Check 5514 60.00 MECHANICAL - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Account Code Current Pmts 000.322.102.00.0 60.00 Total: $60.00 Printed: 10 -08 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http://wwwatukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: M08 -076 Address: 821 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 03/12/2008 Applicant: TORRID Issue Date: Receipt No.: R08 -01952 Payment Amount: $271.00 Initials: WER Payment Date: 06/05/2008 09:57 AM User ID: 1655 Balance: $0.00 Payee: TIMBERWOLFFCONSTRUCTION TRANSACTION LIST: Type Method Descriptio Amount rinr.• RPraint -(16 Payment Check 2219 271.00 ACCOUNT ITEM LIST: Description MECHANICAL - NONRES Account Code Current Pmts 000.322.102.00.0 271.00 Total: $271.00 3290 06/05 9711 TOTAL 1981.70 Prink d nR- n5-2nnR Receipt No.: R08 -00725 Payee: AAD: FITCH, INC. ACCOUNT ITEM LIST: Description r1nr. Racaint -nR PLAN CHECK - NONRES elk City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: M08 -076 Address: 821 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 03/12/2008 Applicant: TORRID Issue Date: Initials: JEM Payment Date: 03/12/2008 01:13 PM User ID: 1165 Balance: $271.00 TRANSACTION LIST: Type Method Descriptio Amount Payment Check 003179 67.75 Account Code Current Pmts 000/345.830 67.75 Total: $67.75 Payment Amount: $67.75 . ' , Y 7 10 TOTAL Printari. n3- 17 -711fR COMMENTS: j Dn%c IA- ,v - 4.2nio-i{Y ? C ttvtt r S h.L A c ,„ 1/41 .,.3 - (�-,P � � a 1 o -G N se,' A -4 , `, - 1+, -- AJ to . � Date Called: .. ?e'er; 0 erv.1, kie fr I \NA I Special Instructions: Date Wanted: /0—/6-61__ _. Requester: Phone No: (2-42 -9 4'- e � Projest. 7 0 "'rid Type of Ins ection: F //L ii j Add2s / ///f Date Called: Special Instructions: Date Wanted: /0—/6-61__ p.m. Requester: Phone No: (2-42 -9 4'- e � INSPECTION RECORD Retain a copy with permit INSPECTION O. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. 12— (206)431 -3670 \ El Approved per applicable codes. 0 Corrections required prior to approval. Date: t? o 0 REINSPECTION FEE QUIRED. Pr or to inspection, fee must be pal at 6300 Southcenter Blvd. Suite 100. all to schedule reinspection. Receipt No.: 'Date: ittarAtirialbi COMMENTS: Type ofpis�c , " , � , t mul e-c_A. . Addre ' S AA Date Called: �J��_ —c r: �. • • J ,N� t �v�"I�,c__ C p i -e Si J r-e A: f -f"eJ- i c, . - 4 S`t`> )-,,k-,if"... 9 (' r 31 ‘''a it JA ( *PP CP .i-f 'ear!) a Project r3 r 7 d , • Type ofpis�c , " , � , t mul e-c_A. . Addre ' S AA Date Called: Special Instructions: .Sly hie 5t.. A -0,J^) Date Wanted: 'a.r . /6 - q - c' e p.m. Requester: Phone _ 5(-11 1814/1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NQ: CITY OF TUKWILA BUILDING DIVISION / 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. M - 6 7, Corrections required prior to approval. Inspec r:• 1 Date:, 3 • 17 $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: COMMENTS: ' Ad�d/re7– I S k (AC kt,K. 1S 3 c„,,, op, “.r ,# > A 4. ∎ Le L S t( --a, Z M Ai a-, pAis . Projec r. Type onspectipn: Ad�d/re7– I S k / f Date Called: Special Instructions: �� it ,v _1 1 f c �' a 6 2 • E 6 - 0 ( 5t., ( 14 W/t Date Wanted a /0 s-- JO v p.m. Requester: Phone No: 7 J —c i (Q 7 .8ei 44 4t Z PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION NO. LI Approved per applicable codes. INSPECTION RECORD Retain a copy with permit Mgr- 0 7{p Corrections required prior to approval. $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: (Receipt No.: 'Date: Project: f �fv' a Type of Inn: Address��� C k // Date Called: Special Instructions: Date Wanted ��� /(� a ��lflJ V (,1 en Requester: Phone No: INSPECTION RECORD A� �` Retain a copy with permit / `7 0 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION • 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: e# 41 4 M4.. ,i1 , � Q 77--- 141 1:2fr y . thi4 Receipt No.: Date: El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. COMMENTS: Sprinklers: Fire Alarm: Type of Inspection: / /l/ f 1t' Cf-I Address: % 2 ; Suite #: , , 'Yl0 c f _ , Contact Person: i -,G.,. 179 i) Special Instructions: Phone No.: Z6 - i « -I/1 711 - L 11 'k /f -tf - r• 0 apt x 4.55 - rY ?ei ( R - --- (),/Z.. = /` t: -F /I/ , - e-- !)k lb i7vr rZ iMA o I - /ry A•7 /- 41 - O.vr_ y. -- 4 5 { 1 pikt -ii- ( 7 k Project: / U ; ; ;, Sprinklers: Fire Alarm: Type of Inspection: / /l/ f 1t' Cf-I Address: % 2 ; Suite #: , , 'Yl0 c f _ , Contact Person: i -,G.,. 179 i) Special Instructions: Phone No.: Z6 - i « -I/1 711 1 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: I Monitor: Pre -Fire: I Permits: Occupancy Type: PERMIT U MBEF CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 INSPECTION NUMBER ri Approved per applicable codes. Word /Inspection Record Form.Doc INSPECTION RECORD Retain a copy with permit 1/13/06 Corrections required prior to approval. I Inspector: 7 r i Date: f / ° / 1 . / Hrs.: n $> 0.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 Project Info Project Address TORRID Date 3/7/2008 WESTFIELD SOUTHCENTER MALL For Building Department Use TUKWILLA, WA 98188 Applicant Name: DON PENN CONSULTING ENGINEER Applicant Address: 635 WESTPORT PKWY, STE 300 GRAPEVINE, TX. 760 Applicant Phone: 817 -410 -2 858 2004 Washington State Nonresidential Energy Code Compliance Form Project Summary PRJ -SUM 2004 Washington State Nonresidential Energy Code Compliance Forms ALE COP" PP it No REVIEwEO CODE COMPLIANCE APPROVE MAR 2 1 20 Revised May 2005 F ... CITY Lit t u� MAR 12 2008 PERMIT CENTER Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Project Info Project Address TORRID Model No. Dat 3/7/2008 Total CFM WESTFIELD SOUTHCENTER MALL SEER or EER For Building Dept. Use Location TUKWILLA, WA 98188 TRANE Applicant Name: DON PENN CONSULTING ENGINEER 3400 Applicant Address: 635 WESTPORT PKWY, STE 300 GRAPEVINE, TX. 76051 Applicant Phone: 817 -410 -2858 Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Brand Name Model No. Capacity Btu /h Total CFM OSA CFM or Econo? SEER or EER IPLV Location RTU -1 TRANE TSC102 105000 3400 700 10.30 11.80 PLENUM 2004 Washington State Nonresidential Energy Code Compliance Form Mechanical Summary MECH -SUM 2004 Washington State Nonresidential Energy Code Compliance Forms Project Description Briefly describe mechanical system type and features. Includes Plans Drawings must contain notes requireing compliance with commissioning requirements - Section 1416 'If available. 2 As tested according to Table 14 -1A through 14 -1G. 3 If required. 4 COP, HSPF Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). Compliance Option ® Simple System O Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Heating Equipment Schedule Equip. ID RTU -1 Brand Name TRANE Model No. TSC102 Capacity Btu /h 61434 Total CFM 3400 OSA cfm or Econo? 700 Input Btuh Output Btuh Efficiency PLENUM Fan Equipment Schedule Equip. ID Brand Name Model No. CFM S P' HP /BHP Flow Control Location of Service Mechanical Summary (back) MECH -SUM System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling U Constant vol? ❑ Air cooled? ❑ Packaged sys? ❑ <20,000 Btuh? or Cooling Only: S lit system? El p � y 11} Economizer included? If Heating Only: ❑ <5000 cfm? ❑ <70% outside air? Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. <5000 cfm? Use Complex Systems (section 1430) Econo Included? Ingle Package Unit? ool Ca Air Cooled, Constant Vol? otal Ca.. wo economize <240,000 Btuh or 10 %? plit Syste <= 84,000 Btuh? Outd... or Adjacent to • utdoors' ool Ca <54,000 Btuh? Heating Only Yes — <70% OSA Yes N 2004 Washington State Nonresidential Energy Code Compliance Form Reference Section 1421 / Heating /Cooling or Cooling Only Yes Yes Simple System Allowed (section 1420) Reference Section 1423 Yes <20,000 Btuh? Yes Yes Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. Cooling Equipment Schedule Equip. ID Brand Name Model No. Capacity Btu /h Total CFM OSA CFM or Econo? SEER or EER IPLV Location TUKWILLA, WA 98188 Applicant Name: DON PENN CONSULTING ENGINEER Applicant Address: 635 WESTPORT PKWY, STE 300 GRAPEVINE, TX. 76051 Applicant Phone: 817 -410 -2858 Fan Equipment Schedule Equip. ID Brand Name' Model No. CFM Sp HP /BHP Flow Control Location of Service Efficiency TUKWILLA, WA 98188 Applicant Name: DON PENN CONSULTING ENGINEER Applicant Address: 635 WESTPORT PKWY, STE 300 GRAPEVINE, TX. 76051 Applicant Phone: 817 -410 -2858 Heating Equipment Schedule Equip. ID Brand Name Model No. Capacity Btu /h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency TUKWILLA, WA 98188 Applicant Name: DON PENN CONSULTING ENGINEER Applicant Address: 635 WESTPORT PKWY, STE 300 GRAPEVINE, TX. 76051 Applicant Phone: 817 -410 -2858 Project Info Project Address TORRID Date 3/7/2008 WESTFIELD SOUTHCENTER MALL For Building Dept. Use TUKWILLA, WA 98188 Applicant Name: DON PENN CONSULTING ENGINEER Applicant Address: 635 WESTPORT PKWY, STE 300 GRAPEVINE, TX. 76051 Applicant Phone: 817 -410 -2858 2004 Washington State Nonresidential Energy Code Compliance Form Mechanical Summary MECH -SUM 2004 Washington State Nonresidential Energy Code Compliance Forms Project Description Briefly describe mechanical system type and features. ❑ Includes Plans Include documentation requiring compliance with commissioning requirements, Section 1416. 1 If available. 2 As tested according to Table 14 -1A through 14 -1G. 3 If required. 4 COP, HSPF Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). Revised May 2005 Compliance Option Q Simple System Q Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. 2004 Washington State Nonresidential Energy Code Compliance Form Mechanical Summary (back) MECH -SUM System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling ❑ Constant vol? ❑ Air cooled? ❑ Packaged sys? ❑ <20,000 Btuh? or Cooling Only: Split system? ❑ p � y ❑Economizer included? If Heating Only: ❑ <5000 cfm? <70% outside air? Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. Heating Only Reference Section 1421 Heating /Cooling or Cooling Only ingle Package Unit? otal Ca•. wo economize <240,000 Btuh or 10 %? plit Syste <= 84,000 Btuh? Outd. or Adjacent to • utdoor ool Ca. <54,000 Btuh? Yes Econo Included ?› Yes Reference Section 1423 Yes Yes of Ca <20,000 \uh? Yes • Simple System Yes _0. Allowed (section 1420) A Yes Use Complex ► Systems (section 1430) Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. Y ec anica - omp ex Systems Checklist MECH -COMP 2004 Washington State Nonresidential Energy Code Compliance Forms Revised May 2005 Project Address TORRID Date 3/7/2008 The following additional information is necessary to check a mechanical permit application for a complex mechanical system for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Use the checklist as a reference for notes added to the mechanical drawings (see the MECH- CHK checklist for additional system requirements). This information must be on the plans since this is the official record of the permit. Having this information in separate specifications alone is NOT an acceptable alternative. For Building Department Use Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes ADDITIONAL CHECKLIST ITEMS FOR COMPLEX SYSTEMS ONLY 1431.1 Field assem. sys. Provide calculations 1432.1 Setback & shut -off Indicate separate systems or show isolation devices on plans 1432.2.1 Air system reset Indicate automatic reset 1432.2.2 Hydr. system reset Indicate automatic reset 1433 Air Economizer Indicate economizer on equipment schedule or provide calculations to justify exemption and demonstrate 10% higher efficiency for equipment with out economizer. 1433 Water Economizer Indicate water economizer and provide calculations if 1433 Exception 2 is utilized 1434 Separate air sys. Indicate separate systems on plans 1435 Simul. htg. & clg. Indicate that simultaneous heating and cooling is prohibited, unless use of exception is justified 1436 Heat recovery Indicate heat recovery on plans; complete and attach heat recovery calculations 1437 Elec. motor effic. MECH -MOT or Equip. Schedule with hp, rpm, efficiency 1438 Variable flow sys. Indicate variable flow on fan and pump schedules 1439.1 Kitchen Hoods Indicate uncooled and unheated make -up air IF'r. ...�r .x.......1....1 1439.2 i..�...... Fume Hoods ........L:.. Indicate VAV, unheated /uncooled or heat rec. makeup :�_ _I_ -_a pr.anwuv�.. Decision Flowchart Use this flowchart to determine how the requirements of the Complex Systems Option apply to the project. Refer to the indicated Code sections for more complete information on the requirements. Section 1411.1 Equipmen Efficiency Shall Meet Tables 14 -1A through 14 -1G 2004 Washington State Nonresidential Energy Code Compliance Form Air System Serving Multiple Zones? 1411,1 Intermittent Ignition Device & Power Venting or Damper, 0.75% Maximum Jacket Loss 1412.6 Modulating or Staged Combustion Controls Required Section 1431.1 Calculations of Total On -Site Energy Input & Ouput Required (continued on back) Section 1432.2.1 Supply Air Reset Controls Required Capacity of H No Heating System > 00,000 Btuh? Yes No Section 1432.2.2 Hot Water Supply Temperature Reset Required Mechanical - Complex Systems (back) MECH -COMP 2004 Washington State Nonresidential Energy Code Compliance Forms t0% Air Econ Provided? Section 1413 Water Cooled w/Water Econo? pply Air >5,0 cfm & OSA > 70% otor Incl. I qpmt. Covr'd by Tbl 14- 1A -14- 1G? EER 10% Better than Code Section 1436 50% Effective Heat Recovery Required Multi -speed Motor in Multi - .eed system? Section 1437 Motors Must Meet Efficiencies in Table 14 -4 Yes 2004 Washington State Nonresidential Energy Code Compliance Form Yes Yes No itchen Exhau Hood > 5,000 > Yes-• cfm? No DONE Yes-* Yes al Cap. cono <= 480,00 Btuh or 20% of otal Cap.? Yes Yes Section 1435 Zone Controls Must Reduce Supply Air Quantity Before Reheating /Recooling Section 1439.1 No Heating or Cooling for at Least 50% of Make -up Air r Yes 0 ► System or Zon - w/ Simultaneous Htg. & Clg.? Application Involves Variable Flow? Yes "" Yes-* Yes ► • Section 1433 Air -Side Economizer Required 1 Yes Yes Section 1438 Variable Flow Devices Required Yes Section 1439.2 One Required: a. 50% VAV Exhaust & Make -up 75% Direct Makeup w/ Tempering Only Heat Recovery per 1436 Constant Volume w/ < 50fpm Face Velocity b. c. d. Yes Revised May 2005 Open Motors Closed Motors 3,600 1,800 1,200 3,600 1,800 1,200 Efficiency ( %) Efficiency ( %) - 82.5 80.0 75.5 82.5 80.0 82.5 84.0 84.0 82.5 84.0 85.5 84.0 84.0 85.5 84.0 84.0 86.5 84.0 86.5 86.5 85.5 87.5 87.5 85.5 87.5 87.5 87.5 87.5 87.5 87.5 88.5 88.5 88.5 89.5 89.5 8&5 89.5 90.2 89.5 89.5 89.5 89.5 91.0 90.2 90.2 91.0 90.2 90.2 91.0 91.0 90.2 91.0 90.2 91.0 91.7 91.7 91.0 92.4 91.7 91.0 924 92.4 91.0 92.4 91.7 91.7 93.0 93.0 91.7 93.0 93.0 92.4 93.0 93.0 92.4 93.0 93.0 93.0 93.6 93.6 93.0 93.6 93.6 93.0 94.1 93.6 93.0 94.1 93.6 9a0 94.1 94.1 93.6 94.5 94.1 93.6 94.5 94.1 94.5 94.5 94.1 93.6 95.0 94.5 94.5 95.0 95.0 94.5 95.0 94.5 95.0 95.0 95.0 Electric Motors MECH -MOT 2004 Washington State Nonresidential Energy Code Compliance Forms Project Address Complete the following for all design A & B squirrel -cage, T -frame induction permanently wired polyphase motors from 1 hp to 200 hp having synchronous speeds of 3600, 1800 or 1200 rpm (unless one of the exceptions below applies). Motor No. or Location Minimum Nominal Full -Load Efficienc Synchronous Speed (RPM) HP 1.0 1.5 2.0 3.0 5.0 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 HP 2004 Washington State Nonresidential Energy Code Compliance Form TORRID Type (open /closed) closed closed closed Description of Application or Use Date 3/7/2008 For Building Department Use Synch. Speed 1200 1200 1200 Revised May 2005 Min.Nom. Full load Efficiency 87.5% 87.5% 87.5% Exceptions: 1. Motors in systems designed to use more than one speed of a multi -speed motor. 2. Motors already included in the efficiency requirements for HVAC equipment (Tables 14 -1 or 14 -2) . 3. Motors that are an integral part (i.e. not easily removed and replaced of specialized process equipment (i.e. equipment which requires a special motor, such as an explosion - proof motor). 4. Motors integral to a listed piece of equipment for which no qualifying motor has been approved (i.e. if the only U.L. listing for the equipment is with a less- efficient motor and there is no energy - efficient motor option). For motors claiming an exception, list motor and note which exception applies. 2004 Washington State Nonresidential Energy Code Compliance Forms Revised May 200E Project Address TORRID Date 3/7/2008 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance yes 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule M2 a • 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency • a • 1411.1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket loss 1412 HVAC controls yes 1412.1 Temperature zones Indicate locations on plans Ml a • 1412.2 Deadband control Indicate 5 degree deadband minimum • a • 1412.3 Humidity control Indicate humidistat • a • 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types yes 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage Mi • a . 1412.4.2 Optimum Start Indicate optimum start controls • a • 1412.5 Heat pump control Indicate microprocessor on thermostat schedule . a. 1412.6 Combustion htg. Indicate modulating or staged control yes 1412.7 Balancing Indicate balancing features on plans M2 1422 Thermostat interlock Indicate thermostat interlock on plans • a . 1423 Economizers Equipment schedule 1413 Air economizers a • 1413.1 Air Econo Operation Indicate 100% capability on schedule a. • 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb a • 1413.2 Water Econo Doc Indicate clg load & water econoe & clg tower performance a • 1413.3 Integrated operation Indicate capability for partial cooling • a . 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems yes 1414.1 Duct sealing Indicate sealing necessary Ml yes 1414.2 Duct insulation i Indicate R -value of insulation on duct M2 yes 1415.1 Piping insulation Indicate R -value of insulation on piping M2 1416 Completion Requirements yes 1416.1&2 Drawings & Manuals Indicate requirement for record drawings and operation docs. M2 yes 1416.3.2 Air Balancing Indicate air system balance requirements M2 a• 1416.3.3 Hydronic Balancing Indicate hydronic system balance requirements • • a • 1416.4 Commissioning Indicate requirements for commissioning and prelim. Report • • a . 1424 Separate air sys. Indicate separate systems on plans Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. • a. 1441 Elec. water heater Indicate R -10 insulation under tank • a. 1442 Shut -off controls Indicate automatic shut -off _. yes 1443 Pipe Insulation Indicate R -value of insulation on piping P1 • a. 1452 Heat Pump COP Indicate minimum COP of 4.0 • a . 1452 Heater Efficiency Indicate pool heater efficiency • a. 1453 Pool heater controls Indicate switch and 65 degree control • a. 1454 Pool covers Indicate vapor retardant cover a • 1454 Pools 90+ degrees Indicate R -12 pool cover If "no" is circled for any question. provide exnlanatinnr 2004 Washington State Nonresidential Energy Code Compliance Form 2004 Washington State Nonresidential Energy Code Compliance Form Mechanical Permit Plans Checklist 2004 Washington State Nonresidential Energy Code Compliance Forms MECH -CHK Revised May 200 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14-1G. If a nationally recognized certification program exists for a product covered in Tables 14 -1A through 14.1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings > 225,000 Btu /h (65 kW) shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings > 225,000 Btu /h (65 kW), including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124.1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Pack electric equipment providing both heating and cooling with a total cooling capacity greater than 20,000 Btu /h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to. the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods-of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual off -hour controls. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity ( nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings three or more stories in height. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum start controls shall be designed to automatically adjust the start time of an HVAC system each day to bring the space to desired occupied temperature levels immediately before scheduled occupancy. The control algorithm shall, as a minimum, be a function of the difference between space temperature and occupied setpoint and the amount of time prior to scheduled occupancy. 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start -up, set -up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shall indicate when supplemental heating is being used through visual means (e.g., LED indicators). 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. Exceptions: 1. Boilers. 2. Radiant Heaters. .7 Balancing: Each air supply outlet or air or water terminal device shall have a means for balancing, including but not limited to, dampers, temperature and pressure test connections and balancing valves. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry - bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry -bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu /h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413,4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246- 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches: seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut -off damper complying with Section 1412.4.1. Once outside air ducts meet the above listed requirements, any runs within conditioned space shall comply with Table 14 -5 requirements. Other ducts and plenums shall be thermally insulated per Table 14 -5. Exceptions: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a zone that serves that zone. 1415 Piping Systems 1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14 -6. Exception: Piping installed within unitary HVAC equipment. Water pipes outside the conditioned space shall be insulated in accordance with Washington State Plumbing Code (WAC 51 -26) 1416 Completion Requirements (Refer to NREC Section 1416 and the Building Commissioning Guidelines, published by the Building Commissioning Association, for complete text and guidelines for building completion and commissioning requirements.) EF CAE < 50 gal storage 0.58 0.71 50 to 70 gal storage 0.57 0.71 > 70 gal storage 0.55 0.70 2004 Washington State Nonresidential Energy Code Compliance Form Mechanical Permit Plans Checklist 2004 Washington State Nonresidential Energy Code Compliance Forms MECH -CHK Revised May 200 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14-1G. If a nationally recognized certification program exists for a product covered in Tables 14 -1A through 14.1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings > 225,000 Btu /h (65 kW) shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings > 225,000 Btu /h (65 kW), including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124.1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Pack electric equipment providing both heating and cooling with a total cooling capacity greater than 20,000 Btu /h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to. the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods-of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual off -hour controls. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity ( nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings three or more stories in height. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum start controls shall be designed to automatically adjust the start time of an HVAC system each day to bring the space to desired occupied temperature levels immediately before scheduled occupancy. The control algorithm shall, as a minimum, be a function of the difference between space temperature and occupied setpoint and the amount of time prior to scheduled occupancy. 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start -up, set -up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shall indicate when supplemental heating is being used through visual means (e.g., LED indicators). 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. Exceptions: 1. Boilers. 2. Radiant Heaters. .7 Balancing: Each air supply outlet or air or water terminal device shall have a means for balancing, including but not limited to, dampers, temperature and pressure test connections and balancing valves. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry - bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry -bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu /h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413,4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246- 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches: seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut -off damper complying with Section 1412.4.1. Once outside air ducts meet the above listed requirements, any runs within conditioned space shall comply with Table 14 -5 requirements. Other ducts and plenums shall be thermally insulated per Table 14 -5. Exceptions: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a zone that serves that zone. 1415 Piping Systems 1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14 -6. Exception: Piping installed within unitary HVAC equipment. Water pipes outside the conditioned space shall be insulated in accordance with Washington State Plumbing Code (WAC 51 -26) 1416 Completion Requirements (Refer to NREC Section 1416 and the Building Commissioning Guidelines, published by the Building Commissioning Association, for complete text and guidelines for building completion and commissioning requirements.) DEPARTMENTS: b B i d ng Division Public Works Complete Comments: Documents/routing sl ip.doc 2 -28 -02 APPROVALS OR CORRECTIONS: PERMIT COORD COPY � PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M08 -076 DATE: 03 -13 -08 PROJECT NAME: TORRID SITE ADDRESS: 821 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued 'b1 / Fire Prevention Structural DETERMINATI N OF COMPLETENESS: (Tues., Thurs.) Incomplete Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: Planning Division Permit Coordinator DUE DATE: 03-18-08 Not Applicable No further Review Required DATE: Not Approved (attach comments) DATE: P DUE DATE: 04-1508 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License TIMBECIO21DM Licensee Name TIMBERWOLFF CONSTRUCTION INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601859639 Ind. Ins. Account Id SECRETARY Business Type CORPORATION Address 1 1659 W ARROW RTE Address 2 City UPLAND County OUT OF STATE State CA Zip 91786 Phone 9099490380 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 3/14/1998 Expiration Date 3/8/2010 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date WOLFF, MICHAEL EDWARD PRESIDENT 03/14/1998 WOLFF, MONIQUE M SECRETARY 03/14/1998 WOLFF, GLADYS VICE PRESIDENT 03/14/1998 Look Up a Contractor, Electric or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond Company Bond Account Effective Expiration Cancel Impaired Bond Received https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= TIMBECIO21DM 06/05/2008 T TITLE SHEET SEPARATE PERMIT I Dl DEMOLITION PLAN I REQUIRED Kin: I Mec anical I :.L' ttArtrical Al FLOOR PLAN Of plumbing I -. , - A2 REFLECTED CEILING PLAN I n•. -.. _i -r•.,Ii.Eila A3 INTERIOR ELEVATIONS DU o If DIVISION A3A INTERIOR ELEVATIONS A4 FINISH AND RESPONSIBILITY SCHEDULE A5 STOREFRONT ELEVATION AND ENLARGED STOREFRONT PLAN A5A STOREFRONT SECTIONS A6 FIXTURE / FLOOR FINISH PLAN A7 SECTIONS AND DETAILS AS SECTIONS AND DETAILS Ml MECHANICAL PLAN M2 MECHANICAL NOTES AND SPECIFICATIONS P1 PLUMBING PLAN, NOTES AND DETAILS El ELECTRICAL POWER PLAN E2 ELECTRICAL LIGHTING PLAN E3 ELECTRICAL SCHEDULES, DIAGRAMS AND NOTES i ROTOTIt +E'RENDERING - ACTUAL STORE MAY VARY SPACE # 540 ratro Tom. 13i:3 F �. S IS Sr. SI Sr. NORDSTROM f I!REE LEW.LS • M. C L EI � qp ' ti • Or • gala Ti THREE KEY PLAN �ll PROJECT LOCATION J ;1� • d, • 4 WESTFIELD SOUTHCENTER MALL (LEVEL 1 OF 2) VICINITY MAP TUKWILLA, WASHINGTON mervyltrs , WO LEVELS JCPenney IHIrE L ‘N 1. PROJECT NAME: TORRID 2. PROJECT DESCRIPTION: - CLOTHING SALES (RETAIL) ALTERNATIVE SIZES 3. PROJECT LOCATION: WESTFIELD SOUTHCENTER MALL 633 SOUTHCENTER MALL SPACE NO. 540 TUKWILA, WASHINGTON 98188 HOT TOPIC dba TORRID . 18305 E. SAN JOSE AVENUE CITY OF INDUSTRY, CALIFORNIA 91748 (626) 839 -4682 BRANDON SANCHEZ bsanchez@hottopic.com 5. LANDLORD: WESTFIELD CORPORATION 11601 WILSHIRE BOULEVARD — 11TH FLOOR LOS ANGELES, CALIFORNIA 90025 PROJECT MANAGER: JOSH KIMMEL PHONE: (310) 893 -4761 6. TENANT'S ARCHITECT: AAD :fltch dba FITCH 16435 NORTH SCOTTSDALE ROAD, SUITE #195 SCOTTSDALE, ARIZONA 85254 CONTACT: RON HEDLUND PHONE: (480) 998 -4200 FAX: (480) 998 -7223 E —MAIL: ron.hedlund @fitch.com ALL WORK SHALL BE IN CONFORMANCE WITH, BUT NOT LIMITED TO, THE REQUIREMENTS OF THE FOLLOWING: AND ANY OTHER STATE AND LOCAL CODES HAVING JURISDICTION. 4. TENANT: 7. GOVERNING CODES: 15. MISCELLANEOUS NOTES: PROJECT DATA BUILDING: MECHANICAL: PLUMBING: ELECTRICAL: ENERGY: FIRE: HANDICAP: 8. CONSTRUCTION TYPE: 9. OCCUPANCY: 10. GROSS LEASED PREMISES :. 2,500 SQ. FT. 11. OCCUPANT LOAD: 2 —B M (MERCANTILE) 2006 INTERNATIONAL BUILDING CODE 2006 INTERNATIONAL MECHANICAL CODE 2006 INTERNATIONAL PLUMBING CODE 2005 NATIONAL ELECTRIC CODE WASHINGTON ENERGY CODE 2006 INTERNATIONAL FIRE CODE CURRENT ADA TOTAL NUMBER OF OCCUPANTS = 58 TOTAL NUMBER OF PUBLIC AREA: 1,653 S.F. ± 30 = 56 NON PUBLIC AREA: 372 S.F. - 300 = 2 12. EXIT REQUIREMENTS: . TWO (2) EXITS REQ., TWO (2) EXITS PROVIDED 13. EXIT ILLUMINATION: EMERGENCY EXIT ILLUMINATION SHALL BE PROVIDED AS SHOWN ON SHEET E2. 14. MUNICIPAL REVIEW: CiTY OF TUKWiLA BUILDING DEPARTMENT 6300 SOUTHCENTER BOULEVARD, SUITE #100 TUKWILA, WASHINGTON 98188 CONTACT: ALAN JOHANNESSEN PHONE: (206) 431 -3670 TENANT'S GENERAL CONTRACTOR SHALL VISIT THE PREMISES AND VERIFY ALL EXISTING CONDITIONS PRIOR TO START OF CONSTRUCTION AND SHALL REPORT ALL DISCREPANCIES TO TENANT'S ARCHITECT. TENANT'S GENERAL CONTRACTOR SHALL CONFORM TO ALL REQUIREMENTS REGARDING CONSTRUCTION PROCEDURES, INSURANCE, ETC., AS SET FORTH BY THE LANDLORD. 16. FIRE SPRINKLERS: AN AUTOMATIC FIRE SPRINKLER SYSTEM IS EXISTING WITHIN THIS SPACE. THE CONTRACTOR SHALL REWORK AND MODIFY FOR. NEW ROOM LAYOUT AND CEILING HEIGHTS IN CONFORMANCE WITH N.F.P.A. 13 STANDARDS AND LOCAL CODES & REGULATIONS. ALL WORK SHALL BE DONE BY A QUALIFIED SPRINKLER CONTRACTOR WHO SHALL DESIGN AND PREPARE SHOP DRAWINGS AND SUBMIT THEM TO THE LANDLORD FOR APPROVAL PRIOR TO FABRICATION AND INSTALLATION. SPRINKLER CONTRACTOR SHALL BE LANDLORD APPROVED. HEADS IN CEILING TILES TO BE CENTERED IN TILES WHEN IN A PUBLIC AREA. NOTE: FIRE SPRINKLER DRAWINGS AND HYDRAULIC CALCULATIONS AND CALCULATIONS SHALL BE SUBMITTED BY THE LICENSED FIRE SPRINKLER CONTRACTOR TO THE GOVERNING MUNICIPALITY FOR APPROVAL PRIOR TO ANY WORK BEING PERFORMED. WESTFIELD SOUTHCENTER MALL 633 SOUTHCENTER MALL SPACE NO. 540 TUKWILLA, WASHINGTON • 8188 EMPLOYEES AT ONE TIME "PLAY NETWORK, INC" 8727 N. 148th. AVE. N.E. REDMOND, CA 98052 ERIN REINHARDT ereinhardt©playnetwark.com (425)497 -8100 (425)425 -8181 "MIDWEST LIGHTING" 5250 HOLLYWOOD BOULEVARD LOS ANGELES, CA 90027 MR. JOHN CONDON johnc@midwestlighting.com (323)957 -6012 (323)463 -3441 INDEX OF DRAWINGS TORRID'S VENDORS REVIEWED 'FOR Y'I V CODE coMPL1Ak'CE PP VED , `2. , CITY MAR 12 2008 PERMIT CENyE REVISIONS No changes shall be made to the cope of work without prior approval Building Division NOTE: Revisions will require a new plan submittal and may include additional plan review fees FILE CO If Permit No Akafililk Plar review approval Is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receif of approved FI -! C pyr and conditions is acknowledges / — B /" Date : f/ City of Tukwila BUILDING DIVISION COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and /or monetary liability. SCALE: MIN DRAWN BY: PROJECT No.: 5065 tip C RI 0 CU gm DI sin C 4•0 0 sla W In I a n • I V p _ ■ VI u ism PI V/ 'D I-- 0 in DATE: March lath, 2005 SHEET: NONE R.H. TRD -01-03 d u.' N co NAR 10 Od T I of l8 0 1 rn a ° O I cv M1 C a' 4 3 4 I IQo m Ca " n ' II "11 MECHANICAL PLAN LANDLORD NOTES TENANT SHALL MAINTAIN A MINIMUM OF e UNOBSTRUCTED CLEARANCE HEIGHT IN RETURN AIR PLENUM ABOVE CEILING ALLOWING FOR AIRFLOW BACK TO LANDLORD AIR CONDITIONING UNIT. LANDLORD PROVIDED A TENANT FIRE SERVICE MAIN WITH BRANCH PIPING STUBBED INTO EACH TENANT'S SPACE. LANDLORD'S SPRINKLER SYSTEM IS DESIGNED PER ORDINARY HAZARD GROUP 2 AND THE LATEST REQUIREMENTS OF NFPA -IS. NO ISOLATION VALVES WILL BE PROVIDED OR PERMITTED. TENANT SHALL CONNECT A FIRE SPRINKLER SYSTEM TO LANDLORD'S SPRINKLER SYSTEM WITHIN THE DEMISED PREMISES USING APPROVED MECHANICAL FITTINGS. TENANT SHALL PROVIDE AND INSTALL. ALL BRANCH PIPING AND SYSTEM DESIGNS SHALL BE BASED UPON THE REQUIREMENTS OF THE STATE OF WASHINGTON, CITY OF TUKWI_A FIRE DEPARTMENT. TENANT SHALL ENGAGE THE SERVICES OF A LANDLORD PREFERRED FIRE SPRINKLER CONTRACTOR TO DESIGN, PERMIT AND INSTALL TENANT'S FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH THE BASE BUILDING DESIGN SPECIFICATIONS. SPRINKLER LAYOUT AND PIPE SIZE SHALL BE HYDRAULICALLY DESIGNED ACCORDING TO ORDINARY HAZARD GROUP 2 AND THE LATEST REQUIREMENTS OF NFPA- 18. 0 0 0 0 0 0 0 10 11 12 13 14 KEYED NOTES 24x24, 10 "0 NECK CD -1. BALANCE TO CFM NOTED. NOT USED. 24x24, 22x22 NECK RG -1. T -STAT. MECHANICAL CONTRACTOR TO FURNISH AND INSTALL MECHANICAL 7 DAY T -STAT. MOUNT THERMOSTAT AT 60" A.F.F. PROVIDE PLENUM RATED CONTROL WIRE AND MAKE SYSTEM FULLY FUNCTIONAL. DUCT SMOKE DETECTOR SHALL BE LISTED, LABELED AND INSTALLED PER IMC SECTION 606. EXTEND FULL SIZED CONDENSATE DRAIN LINE TO APPROVED RECEPTOR. 6 "0 TOILET EXHAUST DUCT TO LANDLORD'S CENTRAL EXHAUST. FULL SIZE SUPPLY AND RETURN AIR DUCTS DOWN THROUGH ROOF FROM RTU -1. NEW NOMINAL 8.5 -TON ROOFTOP ELECTRIC /ELECTRIC AC UNIT. PROVIDE NEW CURB. VERIFY WITH LANDLORD STRUCTURAL REQUIREMENTS FOR NEW RTU. ALL ROOF PENETRATION WORK TO BE PERFORMED BY L.L. APPROVED CONTRACTOR. 15x15, 10 "0 NECK CD -2. BALANCE TO CFM NOTED. 12x12, 10 "0 NECK CD -3. BALANCE TO CFM NOTED. 10x8, TO -1 MOUNTED HIGH ABOVE SALES CEILING. PROVIDE 60/40 SPLIT WITH BALANCING DAMPERS AND TURNING VANES. PROVIDE AND INSTALL MINIMUM 4' -O" OF RETURN AIR DUCT. PROVIDE FULL SIZE OPENING IN TO IN TO WITH 1/4" X 1/4" HARDWARE SCREEN. 5 ALE: 1/4" = 1' -0" Mob - o7(9 E�. VSsi Ci. MAR 12 2008 PERMIT CENTER COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and /or monetary liability. LIU SCALE: MIME 7€ DRAWN BY: PROJECT No.: 11 1111111111 1I I 111111111111IIII I C a) V l C r r� C IA V • rrr® em VI oan tra 0 ari Co Co 00 soN DATE Mar-6h 10th, 2005 SHEET: 1 /4 " =1 -0" STAFF TRD - Q T - O3c1 Ln rn a 0 Co 0 ce v U ' is u - a oO 0 c U 0 vi N _ Q 0 Z � - h ) ▪ 0 tp u g g t Qi 3 L1. b 6 .0 • '0 ++ t 0 E 0 H CD cJ Li-1 trl w cc E X ur 13 of I5 F+1 480 998 7223 CONSULTING ENGINEER j - - -� a �, I VLF _ .ucu� - ' , - � — -- - - ..._ ...__ _ - — 200 � � I 11 200 I T ! , ...,....M + , _ _ , I 41114., t s,�vxmzr� �n 4;� 1 1 1 , I I i -� t . < , y�,.,..,. � 1 240 • __, 240 � � 1 � I 1 � L71 2 1, 0 ______ ' r / 1 240 240 10 , „.„_:. ! _ �.... T ___ .�� i 10 I 1 200 10 , ' 11 _j 200 � 10 32x 6 6 .,... 2 0x16 l Ii( j k� i I - I 1 I .'.1 I ll 1 - .>11 • ,,,. _— �.. a __ -- �� -- - ----- __.�______.__._.__ , ".. j -- t ! 2 0 �r .. 10 z ;ice . _ 12x16: -__ �i -�.. �� e - 10 " 1. 1 s r 1 } / .... .. :• ..L _. ' r� 6-- I � I � H t TA -,' -.• '. ��: �. ...- �.�,��x'•:• a", ,.�, «,... 0" " � : w y/ ` - I P " � � {- j j I✓ !t � 0 � - 1 1 I �. }. f 10x16 ti i 2 40 1 240 .Y . 3Y �, 240 . - .., , . ». ,... lam, 3. t L. T .. � � n .n':' 240 i i 240 1 4 '�+^� d ' t .:. »... ,..,' I- F , "�- i i - ...._. _ -�° ; .. .,.....'.. ..... _ .. ,. ,. ,.. .. 1 ur»w...:*:..m. i r i, ' 1 11 ri 4 . MI ' I i i i i 7 I _:_ 1 1 I (` 1 ! I _ i_. _-_ - 1 - - -- -- i r (- _ • 1?.. -... tr r l 0 1 rn a ° O I cv M1 C a' 4 3 4 I IQo m Ca " n ' II "11 MECHANICAL PLAN LANDLORD NOTES TENANT SHALL MAINTAIN A MINIMUM OF e UNOBSTRUCTED CLEARANCE HEIGHT IN RETURN AIR PLENUM ABOVE CEILING ALLOWING FOR AIRFLOW BACK TO LANDLORD AIR CONDITIONING UNIT. LANDLORD PROVIDED A TENANT FIRE SERVICE MAIN WITH BRANCH PIPING STUBBED INTO EACH TENANT'S SPACE. LANDLORD'S SPRINKLER SYSTEM IS DESIGNED PER ORDINARY HAZARD GROUP 2 AND THE LATEST REQUIREMENTS OF NFPA -IS. NO ISOLATION VALVES WILL BE PROVIDED OR PERMITTED. TENANT SHALL CONNECT A FIRE SPRINKLER SYSTEM TO LANDLORD'S SPRINKLER SYSTEM WITHIN THE DEMISED PREMISES USING APPROVED MECHANICAL FITTINGS. TENANT SHALL PROVIDE AND INSTALL. ALL BRANCH PIPING AND SYSTEM DESIGNS SHALL BE BASED UPON THE REQUIREMENTS OF THE STATE OF WASHINGTON, CITY OF TUKWI_A FIRE DEPARTMENT. TENANT SHALL ENGAGE THE SERVICES OF A LANDLORD PREFERRED FIRE SPRINKLER CONTRACTOR TO DESIGN, PERMIT AND INSTALL TENANT'S FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH THE BASE BUILDING DESIGN SPECIFICATIONS. SPRINKLER LAYOUT AND PIPE SIZE SHALL BE HYDRAULICALLY DESIGNED ACCORDING TO ORDINARY HAZARD GROUP 2 AND THE LATEST REQUIREMENTS OF NFPA- 18. 0 0 0 0 0 0 0 10 11 12 13 14 KEYED NOTES 24x24, 10 "0 NECK CD -1. BALANCE TO CFM NOTED. NOT USED. 24x24, 22x22 NECK RG -1. T -STAT. MECHANICAL CONTRACTOR TO FURNISH AND INSTALL MECHANICAL 7 DAY T -STAT. MOUNT THERMOSTAT AT 60" A.F.F. PROVIDE PLENUM RATED CONTROL WIRE AND MAKE SYSTEM FULLY FUNCTIONAL. DUCT SMOKE DETECTOR SHALL BE LISTED, LABELED AND INSTALLED PER IMC SECTION 606. EXTEND FULL SIZED CONDENSATE DRAIN LINE TO APPROVED RECEPTOR. 6 "0 TOILET EXHAUST DUCT TO LANDLORD'S CENTRAL EXHAUST. FULL SIZE SUPPLY AND RETURN AIR DUCTS DOWN THROUGH ROOF FROM RTU -1. NEW NOMINAL 8.5 -TON ROOFTOP ELECTRIC /ELECTRIC AC UNIT. PROVIDE NEW CURB. VERIFY WITH LANDLORD STRUCTURAL REQUIREMENTS FOR NEW RTU. ALL ROOF PENETRATION WORK TO BE PERFORMED BY L.L. APPROVED CONTRACTOR. 15x15, 10 "0 NECK CD -2. BALANCE TO CFM NOTED. 12x12, 10 "0 NECK CD -3. BALANCE TO CFM NOTED. 10x8, TO -1 MOUNTED HIGH ABOVE SALES CEILING. PROVIDE 60/40 SPLIT WITH BALANCING DAMPERS AND TURNING VANES. PROVIDE AND INSTALL MINIMUM 4' -O" OF RETURN AIR DUCT. PROVIDE FULL SIZE OPENING IN TO IN TO WITH 1/4" X 1/4" HARDWARE SCREEN. 5 ALE: 1/4" = 1' -0" Mob - o7(9 E�. VSsi Ci. MAR 12 2008 PERMIT CENTER COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and /or monetary liability. LIU SCALE: MIME 7€ DRAWN BY: PROJECT No.: 11 1111111111 1I I 111111111111IIII I C a) V l C r r� C IA V • rrr® em VI oan tra 0 ari Co Co 00 soN DATE Mar-6h 10th, 2005 SHEET: 1 /4 " =1 -0" STAFF TRD - Q T - O3c1 Ln rn a 0 Co 0 ce v U ' is u - a oO 0 c U 0 vi N _ Q 0 Z � - h ) ▪ 0 tp u g g t Qi 3 L1. b 6 .0 • '0 ++ t 0 E 0 H CD cJ Li-1 trl w cc E X ur 13 of I5 F+1 480 998 7223 CONSULTING ENGINEER MARK MANUFACTURER MODEL INDOOR BLOWER GROSS COOLING CAP EER HEATER (Kw) O.S.A CFM WEIGHT (LB) CFM "ESP HP SEN MBH TOT MBH ENT. AIR DBF WBF RTU -1 TRANE TSC1 O2 3400 .5 1/4 80.1 105.0 80 67 10.3 18.0 700 835 CEILING DIFFUSER TITUS TDC STEEL 12 "x12" 9 "x9" FLANGE 4 -WAY OPPOSED BLADE RG -1 RETURN GRILLE TITUS 23R STEEL MARK AREA SERVED MANUFACTURER MODEL CFM E.S.P. ( MOTOR BAROMETRIC DAMPER DRIVE HP V /PH EF -1 TOILET ROOM BROAN 674 110 0.125 FRAC. 120/1 YES DIRECT CEILING DIFFUSER TITUS TDC STEEL 15 "x15" 14 "x14" FLANGE 4 -WAY OPPOSED BLADE CD -3 M ARK DESCR PTION MANUFACTURER MODEL MATERIAL MODULE BACK PAN SIZE BO TYPE FRONT BLADES DAMPER CD -1 CEILING DIFFUSER TITUS TDC STEEL 24 "x24" - LAY -IN - OPPOSED BLADE CD -2 CEILING DIFFUSER TITUS TDC STEEL 15 "x15" 14 "x14" FLANGE 4 -WAY OPPOSED BLADE CD -3 CEILING DIFFUSER TITUS TDC STEEL 12 "x12" 9 "x9" FLANGE 4 -WAY OPPOSED BLADE RG -1 RETURN GRILLE TITUS 23R STEEL 24 "x24" - LAY -IN - NONE RG -2 RETURN GRILLE TITUS 23R STEEL 14 "x14" - FLANGE - NONE TG -1 TRANSFER GRILLE TITUS 350RL STEEL 10 "x8" - FLANGE LONG NONE SINGLE DOUBLE ABBR. DESCRIPTION • RECTANGULAR DUCT + - �Jr 4, E7773 ROUND DUCT C T r • 45 DEG. TAP: USE AT BRANCH DUCTS ONLY + r • DUCT SPLIT W /DAMPER: USE AT ELBOWS AND TEES: PROPORTION DUCT AREAS BY CFM'S ..J _ -s-- JJ • CURVED ELBOW -MIN. RADIUS R: 1.5 WIDTH 1 � jr 1 • 90 DEG. ELBOW WITH SINGLE RADIUS TURNING VANES 4-- - lir • FLEXIBLE DUCT CONNECTION IIIIII - J r -- 1 - 4 FD FIRE DAMPER / 'r---F-4 it' BALANCING DAMPER (USE O.B.D. UNLESS NOTED OTHERWISE) Ce , NEW TO EXISTING CONNECTION • SPIN -IN FLEX DUCT TAKE -OFF W /DAMPER r • I SA EXH SUPPLY AIR r vii EXHAUST AIR • 1 • RA MAR Moon RETURN AIR • R L REL RELIEF AIR PEF jVII ( CENTER • aA GSA OUTSIDE AIR • T THE X0`1 AT,'` OR ZO °. • T� X T THE OS %S .Ir OOD NOTES: NEW ROOFTOP ELECTRIC /ELECTRIC A/C UNIT 1. SIZE ALL UNITS ON SUMMER AMBIENT TEMPERATURE: 85 °F. 2. UNIT POWER: - VERIFY VOLTAGE/ PHASE WITH ELECTRICAL DRAWINGS. 3. COOLING CAPACITY, MINIMUM HEAT CAPACITY AND CFM ARE MINIMUM OUTPUT REQUIRED. ALL UNITS SHALL HAVE NO LESS THAN 98% OF THESE CAPACITIES. COOLING CAPACITY IS GROSS COIL CAPACITY REQUIRED (FAN HEAT NOT DEDUCTED). 4. PROVIDE NEW CURB, FILTERS AND FILTER RACK SIZED AT 500 FPM VELOCITY. 5. PROVIDE WITH 100% ECONOMIZER AND PROGRAMMABLE THERMOSTAT. 6. PROVIDE WITH GFIC. CONVENIENCE OUTLET. 7. PROVIDE WITH HAIL GUARD. NEW EXHAUST FAN SCHEDULE NEW GRILLE, REGISTER, AND DIFFUSER SCHEDULE ■ NOTE: PRIOR TO CONSTRUCTION/ BID THE CONTRACTOR SHALL VISIT THIS SITE AND FIELD VERIFY THE EXISTING LOCATIONS AND SIZES OF ANY LANDLORD PROVIDED, OR EXISTING, OUTSIDE AIR INTAKES THROUGH ROOF, LANDLORD PROVIDED CHILLED /HOT WATER PIPING MAINS, TOILET EXHAUST MAINS, OUTSIDE AIR DUCTWORK, CONDENSATE LINE MAINS, ETC. THE CONTRACTOR SHALL FIELD VERIFY ANY/ CONDITIONS WHICH MAY CONFLICT WITH THE DESIGN SHOWN ON THESE PLANS. NOTIFY ARCHITECT IMMEDIATELY. COOLING OA DB COOLING IA DB HEATING OA ROOF U- FACTOR LIGHT DIVERS. VENT GEM - MIN OA VENT CFM /PERSON WALL AREA PEOPLE SENS HEAT SENSIBLE HEAT GAIN PEOPLE VENTILATION ROOF LOAD LIGHT LOAD MISC LOAD WALL LOAD TOTAL SENSIBLE TOTAL COOLING LOAD SENS /TOTAL RATIO NOMINAL CFM SENSIBLE HEAT GAIN VENTILATION ROOF LOAD WALL LOAD TOTAL SENSIBLE TAPE AROUND SNUGGLY Z WRAPS PRIOR TO INSTALLING LINE STRAP FLEXIBLE DUCT MAX. 4' -O" LENGTH LAY -IN CEILING A/C EQUIPMENT 24 GA. SHEET METAL COUNTER FLASHING SEE ARCH. DETAIL FOR CANT STRIP. ROOFING �ll ROOF CONSTRUCTION HVAC LOAD SUMMARY 85 75 23 0.100 1.1 700 15.0 0 250 Torrid Westfield Southcenter Mall Tukwilla, WA 98188 2500 SQUARE FEET ASHRAE DESIGN CONDITIONS COOLING LOAD SUMMARY 8333 7595 20750 31240 5120 0 73037 HEATING LOAD SUMMARY 35697 11750 0 47447 TOTAL HEATING LOAD NOMINAL KW ELEC HEAT MINIMUM KW ELEC HEAT (BASED ON 15 DEG F RISE) 2" SQUARE SUPPLY AIR DIFFUSER DETAIL 82915 BTUH 88 % 3350 GEM COOLING OA WB COOLING IA WB HEATING IA LIGHTING WATTS MISC. WATTS SQ FT /PERSON NO OF PEOPLE WALL U- FACTOR PEOPLE LATENT LATENT HEAT GAIN PEOPLE VENTILATION TOTAL LATENT LATENT HEAT GAIN VENTILATION TOTAL LATENT ROUND S.A. DUCTWORK ABOVE CEILING. SEE PLAN FOR DUCT SIZE. 1" WIDE x 20 GA. STRAP W/ TIGHTENING SCREW SECURE STRAP W/ SHEET METAL SCREWS 3" O.C. MAX. 24 "x24" "TITUS" MODEL # DAT, ROUND NECK (SEE SHEET M1 FOR NECK SIZE) BORDER TYPE 3- LAY -IN DIFFUSER WEATHERPROOF SEALING STRIP. PREFABRICATED CURB BY UNIT MANUFACTURER. 47447 BTUH 14 KW 16 KW WOOD CURB INSERT. TAPERED WOOD OR GALV. SHT. METAL, SHIM TO MATCH PITCH OF ROOF. MECHANICAL EQUIPMENT CURB 65 63 70 8321 1500 75 33 0.11 200 6667 3211 9878 0 0 N.T.S. N TS MECHANICAL GENERAL NOTES 1. ALL WORK SHALL COMPLY WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES, LAWS, ACTS AND ALL AUTHORITIES HAVING JURISDICTION, AND LANDLORD'S CRITERIA. 2. THE COMPLETED INSTALLATION SHALL BE IN ACCORDANCE WITH ALL APPLI- CABLE INDUSTRY STANDARDS OF GOOD PRACTICE AND SAFETY; AND THE MANUFACTURER'S STRICTEST RECOMMENDATIONS FOR EQUIPMENT AND PRO- DUCT APPLICATION AND INSTALLATION. 3. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, LICENSES, DOCUMENTS AND SERVICES RELATED TO INSTALLATION OF THE WORK. 4. PRIOR TO SUBMITTING A PROPOSAL, THE CONTRACTOR SHALL VISIT THE SITE AND THOROUGHLY INSPECT ALL EXISTING CONDITIONS TO INSURE THAT THE WORK REPRESENTED ON THE DRAWINGS AND IN THESE SPECIFICATIONS CAN BE INSTALLED AS INDICATED. 5. DUCTWORK SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH ASHRAE AND LATEST SMACNA STANDARDS. PROVIDE TURNING VANES IN ALL ELBOWS; AND MANUAL VOLUME DAMPERS IN ALL BRANCHES, SPLIT - PER DAMPERS, AIR EQUALIZERS, EXTRACTORS, AND SIMILAR DEVICES WHEREVER NECESSARY TO PROPERLY BALANCE THE SYSTEM AND PRODUCE A QUIET AND DRAFTLESS OPERATION. 6. DUCTWORK SHALL BE GALVANIZED SHEET METAL OF LOCK FORMING QUALITY WITH 2" THICK FIBERGLASS INSULATION WITH FOIL VAPOR BARRIER, ALL JOINTS AND SEAMS SHALL BE SEALED IN A MANNER TO PROVIDE A COMPLETE VAPORTIGHT ENCLOSURE. 24 GAUGE UP TO 30 ", 22 GAUGE - 30" AND OVER. ALTERNATE: STANDARD SPIRAL ROUND GALVANIZED SHEET METAL DUCTWORK. WITH 2" THICK FIBERGLASS INSULATION WITH FOIL VAPOR BARRIER, ALL JOINTS AND SEAMS SHALL BE SEALED IN A MANNER TO PROVIDE A COMPLETE VAPORTIGHT ENCLOSURE. 24 GAUGE UP TO 36 "0, 22 GAUGE -36" TO 50 ". FIRST 15 FT. OF DUCT FROM EQUIPMENT SHALL BE LINED 1" HEAVY DENSITY ACOUSTICAL INSULATION. 7 FLEXIBLE DUCTWORK SHALL BE THERMAFLEX "M -KE" WITH ONE INCH EXTER- NAL INSULATION FINISHED WITH A VAPOR BARRIER, U.L. AND 90A LISTED, SHALL BE EQUIPPED WITH DAMPER - EXTRACTOR AT THE SHEETMETAL DUCT AND CIRCULAR COLLAR AT THE DIFFUSER, MECHANICALLY SECURED. 8. FLEXIBLE DUCTWORK SHALL NOT EXCEED 4 FEET IN LENGTH; BENDS SHALL NOT RESTRICT THE INSIDE CROSS- SECTIONAL AREA OF THE DUCT; AND CONNECTION SHALL BE MADE AS DIRECT AS POSSIBLE TO THE MAIN SUPPLY. 9. ALL WORK SHALL BE LOCATED TO AVOID CONFLICTS WITH OTHER TRADES PROVIDE ADEQUATE CLEARANCE FOR ARCHITECTURAL DESIGN, PROPER OPERATION AND SERVICE OF EQUIPMENT. 10. PROVIDE A READY -TO -USE SYSTEM WITH ALL WORK GUARANTEED IN WRI- THING AGAINST DEFECTIVE WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR FROM TURN OVER TO OWNER. 11. CONDENSATE DRAINS: TYPE "M" HARD DRAWN COPPER FOR LINES 1" AND SMALLER, "DWV" HARD DRAWN COPPER FOR 1-1/4" AND LARGER, CONFORMING TO ASTM 888-72. WROUGHT COPPER FITTINGS, DRAINAGE TYPE FOR LINES 1-1/4" AND LARGER. SOLDER WITH 50/50 SOLD 12. DUCTWORK SHALL BE "FACTORY MADE" CLASS 1 GALVANIZED SHEET METAL WITH IRON SUPPORTS SECURED TO OVERHEAD MEMBERS AT 5' -0" DUCTWORK MATERIALS SHALL BE PER INTERNATIONAL MECHANICAL CODE, 2003. 14. PROVIDE DUCT SMOKE DETECTORS IN RA DUCTS, TO OVER RIDE UNIT AND PROVIDE SHUTDOWN WHEN UPON DETECTION OF SMOKE. HVAC NOTES 3. PROVIDE NECESSARY TURNING VANES, SPLITTER DAMPERS, VOLUME EXTRACTORS AND OTHER FEATURES NEEDED FOR A SMOOTH AND CONTROLLED FLOW OF AIR. 5. PROVIDE PROPER DUCT TRANSITIONS FOR ACTUAL HVAC UNITS INSTALLED. ROOF PENETRATIONS, IF ANY, TO BE MADE AS PER L.L. SPECS. VERIFY DETAILS WITH L.L.. 6. PROVIDE AND INSTALL THERMOSTATS AT LOCATIONS AS DIRECTED BY THE ARCHITECT. 7. COORDINATE ACTUAL LOCATIONS OF DIFFUSERS, REGISTERS AND GRILLES WITH CEILING DETAILS AND OTHER FEATURES SUCH AS LIGHTING FIXTURES ETC. THAT MAY AFFECT PLACEMENT OF THE HVAC SYSTEM COMPONENTS. 8. GENERAL CONTRACTOR SHALL SUPPLY ALL EQUIPMENT CONTROLS AND WIRING. COORDINATE WITH MALL REPRESENTATIVE FOR INTERLOCKING WITH MALL CONTROL SYSTEM (AS REQUIRED). DUCTWORK SYMBOLS CODE COM: p R V! LIAR l 21 1. ALL WORK TO BE AS PER THE L.L. SPECS, ALL LOCAL CODES, RULES AND REGULATIONS. ALL WORK TO BE AS PER ASHRAE AND SMACNA GUIDELINES. R. City Ot Tu 13. PROVIDE AS PART OF THE MECHANICAL CONTRACT SERVICES OF AN INDEPENDENT AIR /WATER BALANCING CONTRACTOR CERTIFIED BY THE ASSOCIATED AIR BALANCE COUNCIL. SUBMIT 3 COPIES OF THE BALANCE REPORT TO ARCHITECT /OWNER AND LL FOR APPROVAL. 2. ALL DUCT SIZES SHOWN ARE CLEAR INSIDE. ALL DUCTS TO BE SHEET METAL DUCTS AS PER ASHRAE AND SMACNA GUIDELINES. 4. LOCATIONS SHOWN OF HVAC EQUIPMENT AND DUCTS ARE SCHEMATIC ONLY. VERIFY STRUCTURAL DETAILS AND OTHER DETAILS THAT WILL AFFECT ROUTING AND PLACEMENT OF THESE COMPONENTS. IF MORE SUPPORTS ARE NEEDED FOR HVAC EQUIPMENT, COORDINATE WITH THE ARCHITECT. COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and /or monetary liability. SCALE: 00 mm. 00 L a e C 41. C C sit r LA ‘10 • C +.• Zi 4 1 2 , W w z Y�, - z '~ W a u) z� 'a z Z f P? a � h51n (0 "'W Z Z a. oo 00 (D(a DRAWN BY: PROJECT No.: IIIIIIIIIIIIIIII IIII!I111!!IIII 11111111 , 1111 11 I z 0 ce trt ua N J a. a z DATE March IOth, 200& SHEET: N.T.S. STAFF TAD -Q 1 -O g g CD 3 6L H ii E a V 14 of IP