Loading...
HomeMy WebLinkAboutPermit M08-088 - WESTFIELD SOUTHCENTER MALL - JUST SPORTSJUST SPORTS 2467 SOUTHCENTER MALI, M08 -088 Parcel No.: 6364200010 Address: Suite No: CitAtof Tukwila 2467 SOUTHCENTER MALL TUKW Tenant: Name: JUST SPORTS Address: 2467 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: JIM KLOSTER Address: 1507 S 18 AVE , YAKIMA WA Contractor: Name: ALL SEASONS HTNG /AIR CON INC Address: PO BOX 9006 , YAKIMA WA Contractor License No: ALLSEHA265Q2 DESCRIPTION OF WORK: INSTALL DUCT AND 2 VAV BOXES WITH ELECTRIC HEATERS AND THERMOSTAT Value of Mechanical: $5,000.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat /Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC-10/06 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT EQUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 0 0 0 0 0 0 0 0 * *continued on next page ** M08 -088 Permit Number: M08 -088 Issue Date: 04/16/2008 Permit Expires On: 10/13/2008 Phone: Phone: 509 - 457 -3634 Phone: 509 522 -0672 Expiration Date: 03/20/2010 Fees Collected: $226.13 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 9 Thermostat 1 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 Printed: 04 -16 -2008 Permit Center Authorized Signature: doc: IMC-10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us kVA- 0E Date: 04II Permit Number: MO8 -088 Issue Date: 04/16/2008 Permit Expires On: 10/13/2008 I hereby certify that I have read and 4xaed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied \\wit lj, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the pi ance of work. I am authorized to sign and obtain this mechanical permit. Signature: .0 Date: /7 / Print Name: � r^ ( q °& \`. This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M08 -088 Printed: 04 -16 -2008 Parcel No.: 6364200010 Address: 2467 SOUTHCENTER MALL TUKW Suite No: Tenant: JUST SPORTS 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tulcwila.wa.us PERMIT CONDITIONS Permit Number: M08 - 088 Status: ISSUED Applied Date: 03/21/2008 Issue Date: 04/16/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: ** *FIRE DEPARTMENT CONDITIONS * ** 6: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 7: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 8: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 9: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 10: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 11: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 12: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 13: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 14: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 15: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 16: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at doc: Cond -10/06 M08 -088 Printed: 04 -16 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us * *continued on next page ** M08 -088 Printed: 04 -16 -2008 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signatu • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Print Name: IC (- - lam-' doc: Cond - 10/06 M08 - 088 Date: ordinances governing or local laws regulating Printed: 04 -16 -2008 Site Address: • CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 littp://www.ci.tukwila.wa.us 2V67 som,dec.e...�t� tea,// Name: J- ; /1:4$ Mailing Address: V,50 /9 A E -Mail Address: Jrir2 (,sip em.sfist4..e., o.--. Goy Company Name: /V5. t'.ow tr.e�i -....v . o,.. TG . Mailing Address: /50 7 ..5 /8 ze -- A v e • Contact Person: Jim //Zs E -Mail Address: j;.s, �s i Go,�,�! i- t..t/�` p, Gqm Contractor Registration Number: N,52 '099tj E Company Name: , 5c- j)1/tG DGS/ -, _7 G . Mailing Address: /0Y 4 z, r ` 4 ye . Contact Person: / .,l ,,, E -Mail Address: Sc.La eGa4s qt .a iA e ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Contact Person: E -Mail Address: Q:\ Applications \Forms- Applications On Linc\7 -2006 - Permit Applimtion.doc Revised: 9 -2006 bh wil ding Permit No:(! .. Mechanical :Permit No M{ 0:0f PlunibuigiGas ermit o_ Public Vllorks PermitNO ect:No :::::; ........... or.:ote:use:only ...... :...... Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: 6.3612.0-00/0 Suite Number: 2.3/0 Floor: z Tenant Name: J ..,sL .50or - 24 New Tenant: Yes ❑ .. No Property Owners Name: C6_- 2 . / Mailing Address: / /g0/ 1� - e., .Vi $ �,s - h / /0O hos /��.9e,Ls C-/ 9W2,5 City (../ State Zip ::::CONTACT PERSON - who do we contact when your permit is ready to be issued .. Day Telephone: (5o7)7n5'7 3d3V City state zip Fax Number: (509) x152' -,Z./06 GENERAL CONTRACTOR INFORMATION — (Contractor:Information for Mechanical {pg 4) for Plumbing and Gas Piping (pp 5)) City State Zip Day Telephone: (.5099) 937.363/ Fax Number: (50?) y.5jZ' -Z /Ott /075/znv9 Expiration Date: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record City C1/1 7e702_. 41.4 Y870Z, State Zip Day Telephone: (509) Fax Number: (So 9J Y53 - r5F/' Company Name: A / / A Mailing Address: City State Zip Day Telephone: Fax Number: Page 1 of 6 Unit T e: Qty Qty Unit Type:: Qty Unit .Type: Qty Boiler/Compressor: Qty Furnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser ? 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat /Refrig /Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm /Ind E -Mail Address: Use: Residential: New .... ❑ Commercial: New ...X • MECHANICAL PERMIT INFORMATION = 206. -431 3670 MECHANICAL CONTRACTOR INFORMATION Company Name: Ail Se' -Aviv y cl- L / ,4 Mailing Address: /. oX 9006 , J Contact Person: /6,7 4e, zooe,/ V.5. 3 32. aplGa.n Contractor Registration Number:/QLL SE4'A 25602 Valuation of Mechanical work (contractor's bid price): $ .500 0 A '` Scope of Work (please provide detailed info ation): �A5 hi /GGwc /L � Z VA }��OXGf L ' i� Fuel Type: Electric .....0 Gas .... Other: , x i1.1Z Indicate type of mechanical work being installed and the quantity below: Q: \Application, \Forms- Application, On Linc\ -2006 - Pcrmit Applicatinn.doc Revised: 9 -2006 bh Replacement .... ❑ Replacement .... ❑ 111 � ino ZIA 78909 City State Zip Day Telephone: (509) 2 /7 - Fax Number: (5O) 575 78L/T Expiration Date: 3/2.O /,ZOO 9 Page 4 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR UTHORIZED AGENT: Signature: `r / Date: rd, Mailing Address: / 5C 5. /8 Print Name: Date Application Accepted: Date Application Expires: Staff Initials: i Q: Applicniinns \Forms- Applicm ions On Linc\5 -2006 - Permit Application.doc Revised: 9 -2006 bh Day Telephone: <5 7 s7 - 34J1 City State Zip Page 6 of 6 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: M08 -088 Address: 2467 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 03/21/2008 Applicant: JUST SPORTS Issue Date: Receipt No.: R08 -00865 Initials: WER User ID: 1655 Payee: MSI CONSTRUCTION TRANSACTION LIST: Type Method Descriptio Amount Payment Check 8930 226.13 ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES Account Code Current Pmts 000.322.102.00.0 180.90 000/345.830 45.23 Total: $226.13 Payment Amount: $226.13 Payment Date: 03/21/2008 11:09 AM Balance: $0.00 doc: Receiot -06 Printed: 03 -21 -2008 Project (( Type of Address: .,a 4 (t 7 6tl i4 1 t Date Called: Special Instructions: Date Wanted: '7- 2.3- U6. a.m. p.m. Requester: Phone No: ti INSPECTION RECORD Retain a copy with permit IUD - INSPE ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 12- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 - 6 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspe Rec pt No.: ° PL -C � (� 1 rv 'Date: Date: 4.t I '7 Z _ .06 .00 REINSPECTION F REQUIR D. Prior to inspection, fee must be d at 6300 Southcenter vd., Suite 100. Call to schedule reinspection. COMMENTS: (),, r1—� // ,{� //idol WcV � free �Q &vs 's f)o 194 sSsrA 4V 1&i MC— -7-T fy/4 LL VA4 -2. (Ts- 7.—) a, .4..,1 , yd.., no 712- - Se trveS fAA l•• 1.4<- - 2- :. . Date Wanted: 1 ) ) b a.m. P.m- Requester: Phone No: r f ie.r try t. S la ..0 R.- 51--oe A—C raC.. d 40 Ie- 0 "—g, fe car+ tea. ac.cz.ceia ►- Project: Sug t. (),, r1—� Type of Inspection: j � 5 rr o git. c vY IN Address: IA 6,1 fy/4 LL Date Called: Special Instructions: Date Wanted: 1 ) ) b a.m. P.m- Requester: Phone No: Inspector: INSPECTION RECORD Retain a copy with permit PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. ❑ Corrections required prior to approval. (Date: 'i/ 17 1 El $60.00 REINSPECTION FEE REQ RED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project: S j P Fire Alarm: Hood & Duct: Type of Inspection: Address: 9 t f (--) Suite #: �- /N t..- Contact Person: Special Instructions: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER proved per applicable codes. Word /Inspection Record Form.Doc INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRrDEPARTMENT 1/13/06 the City of Tukwila Finance Department. Call to schedule a reinspection.- j40 off /:: PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Corrections required prior to approval. - COMMENTS: Date: 1/(� H Inspector: `_ 5 `/ $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from T.F.D. Form F.P. 113 Cooling Equipment Schedule Equip. ID Brand Name' Model No. Capacity Btulh Total CFM OSA CFM or Econo7 SEER T or EER P�y3 --•• ` M SJ CONs -rsto nowt r, (x��� I50'1 S? itts1 k,40, \ oc. (1) Applicant Phone: C 4% 4- cog C OI!', I -144; e ` r i _ APR 0 : Heating Equipment Schedule Lrlty vt Equip. ID Brand Name' Model No.' Capodte Bluth Total CFM OSA cim or Ecano7 Input Btuh Output • :. I! , icien[y _ Fan E • uipment Schedule Equip. t0 Brand Name Model No.' CFM SP' HPIBHP Flow Control Location of Service - M SJ CONs -rsto nowt r, Applicant Address: I50'1 S? itts1 k,40, \ oc. (1) Applicant Phone: C 4% 4- r i _ 0 : Project Info ProjectAddrees 4-710 ,. 11.fr ... y . Date �g Er f 4 e$� ,Vim _ Building Dgpt Use . _ .. _. . .For UST -bP1' . Applicant Name: M SJ CONs -rsto nowt r, Applicant Address: I50'1 S? itts1 k,40, \ oc. (1) Applicant Phone: C 4% 4- MAR- 14- 2008 (FRI) 14:12 All Seasons Heating & A/C (FAX) 5095757847 P.002/006 CITY OF TUKWILA - BUILDING DIVISION 2005 Washington State Nonresidential Energy Code Compliance Form 2000 Watllinplon aww Nonruidrnid Enner Code Compliance Fame Project Description Briefly describe mechanical system type and features. (!]des Plans Compliance Option FILE COPY Mechanical Summary I IUIECH -SUM .i rT r•RMle •• •, VAV 'Bo% CCCp n,isicA •9`o L.P•e.ua t-ep4- 5 Ion 14-57 ar. x.e ga° v l.pw ` rees6 s e. Nye Dismabe J ti coo SiSS Include documentation requiring compliance with commissioning requirements, Section 1416, (, Simple System Complex System 0 Systems Analysts (See Decision Flowchart (over) for qualifications. Use separate MECH•SUM for simple & complex systems.) Equipment Schedules The following Information Is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill In the required Information below. U I4CE Q 2006 I Erg 12008 CENTEr System Description See Section 1421 for full description of Simple System qualifications. If Heating/Cooling or Cooling Only: j ' Coftstent voR ❑ Split system? ❑ Alr cooled? ❑ Packaged cys7 ❑ <20,000 Btuh? • Economizer Included? • If Heating Only: ❑ <5000 dm? 0 <70% outside alt! MAR- 14- 2008(FRI) 14:12 All Seasons Heating & A/C (FAX)5095757847 P.003/006 CITY OF TUKWILA - BUILDING DIVISION 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Summary (back) MECH -SUM Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Option Must be used. C START ) Complex Systems Reference Heating Only Section 1421 Cooling or Cool i : Only Yes Reference Section 1423 Refer to MECH -COMP Mechanical Complex Systems for assiatence In determining which Complex Systems requirements ere applicable to this project Mectranical- Permit - Plans- 2000 Waehnplan State Nomeeleernal Energy Coda ComPUanao Fame Checklist II M CFI`C Rona/id July 2oar ProJecl - �' D4to The following Information Is necessary to check a mechanical permit application for compliance with the mechanical requirements In th e Waehington State Nonresidential Energy Code. Applicability bee. no, na) Code Section Component Information Required Locetion on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 equipment performance 11 te 1411.4 PKg. elect htg.& cig. List heel pumps on schedule 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency 1411.1 Combustion htg. Indicate Intermittent Ignition, flue /draft damper & JacNet lose 1412 HVAC controls 1412.1 Temperature zones Indicate locations on plans M- I 14122 Deadband control Indicate 5 degree deadband minimum M.1 - k 1412.3 Humidity control Indicate humidlstat f 1412.4 Automatic setback Indicate thermostat with night setback and 7 cliff. day types M,1 • E 1412.4.1 Dampers indicate damper location and auto. controls & max. leakage 14 ..1 I4k 1412.42 Optimum Start Indicate optimum start controls Ntir 1412.5 Heat pump control Indicate microprocessor on thermostat acheawe Nt 1412.6 Combustion htg. Indicate modulating or staged control 1 t6, 1412.7 Balancing Indicate balancing features on plans ti I 141i,' 1412.8 Ventilation Control indicate demand control ventilation for high - occupancy areas for, 1422 Thermostat Interlock indicate thermostat Interlock on plans ,mac 1423 Economizers Equipment schedule 1413 Air economizers 1413.1 Air Econo Operation Indicate 100% capability on schadule fwp- 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F Wb HA 1413.2 Water Econo Doc Indicate trig load & water oconoe & clg tower performance 1413.3 Integrated operation Indicate capability for partial cooling t`4�i' Re 1413.4 Humidification Indicate direct ovap or fog atomization w/ alreconomizer 1414 V Ducting systems 1414.1 Duct sealing Indicate sealing necessary tits1 a 1414.2 Duct insulation indicate Revalue of Insulation on duct M 1415.1 Piping Insulation Indicate R -value of Insulation on piping 1418 Completion Requirements OS 1416.2.1 Commissioning Provide commie/ loving plan P ( 0 14162.2.3 Sye .Uat & Func.Test indicate air and water system balancing & funcUanal testing M - 0 ( 14162.4 Commissioning Indicate O &M manuals, record drawings, staff training M 1 ec 1416.2.5 Comm. Report Indicate requirements for prelim. & final commissioning report M� Ne 1434 Separate air lye. Indicate separate systems on plans Mechanical Summary Form completed and nttactier q ens schedule with types, input/output, efficiency, cfm, hp, economizer -7 -.. r t . . .7', • ■ Is .. e • a • ec ions .r. r • 1440 Service water htg. 1441 Elec. water healer Indicate R -10 Insulation under tank tg 1442 Shut -off controls Indicate automatic shut -off NA, 1443 Pipe Insulation Indicate R -value of Insulation on piping 1452 Heat Pump COP . Indicate minimum COP of 4.0 • kit 1452 Heater Efficiency Indicate pool heaterefficiency N 4 , 1453 Pool heater controls Indicate switch and 65 degree conlroi MAA- 14- 2008(FRI) 14:12 All Seasons Heating & A/C (FAX)5095757847 2006 Wanhlnpton State Nonresidential Energy Code Compliance Form P. 004/006 MAR- 14- 2008(FRI) 14:12 All Seasons Heating & A/C (FAX) 5095757847 2008 Washin ton Sato Nonresidential Ene tl Code Com.11ence Form -Mechanical-Permit-Plans 3009 Waste olen Slaw Prontsakienalal energy Coos ccmaeance Forma III II M EGH -C' K nooses ,nay =O07 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified Wing condition not less than the values Shown lo Telee 14 -1A through 14.10. If a nalonatiy recognized certification program exists fare produ at covered in Tables 144A through 14.10, and It includes provisions for ved(kaeon and challenge of equipment efficiency ratings, than the product shall be limed In Ina certification Program- C3811-fired and of -fired forced air furnaces with Input relings > 225,000 Bluth (e5 kW) and aU unit healers shall also have an intermittent Ipndan orTnternrpted device (HD), and have either mechanical draft (including power venting) or nue damper. A vent damper Is on acceptable alternative to a due damper for furnaces where combustion aide drawn from the conditioned space Ni furnaces with Input ratirtgs 225,000 Bluth (85 kW), including electric furnaces, that are not healed within the conditioned space shall have Picket bsses not exceeding 175% of the Input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test condtions and procedures when mailable. Whore no applicable procedure erdet, dale shall be furnished by Inc equipment manufacturer. 1411.3 Combination Space and Sow Ice Water Heating: For combination space and service water healers with a principal function of providing apace heat. the CombinodAnnuol Efficiency (CAE) may be calculated by using ASHIiAE Standard 124 -1991. Storage water heaters used in combination space hest and water heel applcallon& Shall have either an Energy FAclor (EF) or or CAE of not lees than the following: 1411.4 Pecks equipment providing both healing and ceding with a total cooling capedly greater than 20, Bluth shell be a heat pump. Exception: Unstarfed equipment dwellers or cabinets used solely for pereonel wireteae service facilities. 1412 Controls 1412.1 Temperature Coetrolk: Each tyystem shall be prodded with at loast one temperature control devi e. Each nine shall be controlled by individual thermostatic =hole responding to temperature within the zone. Ala minimum, each floor of a building shall be considered as a separate zone, 14122 Deadband Controls: When used to caned both comfort healing and coaling, zone thermostatic controls shall be capable of a dee:hand or at lead 5 degrees F within which tho supply of healing and co ding energy to the zone la snit( oforteduced to a minimum. Exception's: 1. Special occupancy, spectre usage, or code requirements where deadband controls am not appropriate. 2 Buildings complying with Seethe 1141.4, If In the proposed building energy analysis, healing and cooling thermostat midpoints em set to the same temperature between 70 degrees P and 76 domino F Inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating end cooling modes. 14113 Humidity Controls: Ito system Is equipped with a means for adding mdature, a htnddiatet shell be provided. 14124 Setback and Shut -Off: HVAC systems shell be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day dock and he capable of being sat for seven different day typos per week. It must retain programming and time fora power loss of 10 hours and Include an accessible manual override al up to 2 hours. Exception: 1. Systems serving areas watch require continuous operation at the same temperature attune 2. EqulgmentwIth full load denude or2 kW (0.820 Dlulh) arises may be controlled by readily so:essible manual off hour control,. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant Is sensed fora period of up to 30 minutes. 4. Systems controlled solely by a manually operated Omer capable of operating the system for no more than two houra. 14124.1 Dampers Outside elr Intakes, edteust outlets end relief outlets oendng cotldItioned spaces shall be equipped with dampers which dose au tomailcellY when the system is off or upon power tenure. Star shall and elevator shalt smoke relief openings shall be equipped Witt normally open (lags to open upon toes al power) dampers These dampers sh ell remain dosed until activated by the fete a hum system or other approved smol® detection system. Exceptions: 1. Systeme serving areas which require continuous operation. 2. Combustion air Intakes. 3. Gravity (ramnotorizad) dampers are aocaptablo In buildings lees than 3 store= In height. . rete.e mummer GOTIVOla tar rage - uccupency Areas: teemarrt rantrul ventilation (OCV) Is required for spaces that ere larger than 500112, have a design occupancy for ventilation of greater than 40 people for 1000 1{2 of floor area, end are served by systems with one or more of the folioed = a An atr-slde,economlter, b. Automatic maculating control of the outdoor air damper. or e. A design outdoor airflow grader than 9000 cfm, Ere:options: 1.Syalame with energy recovery complying with Section 1438. 2. Multiple-zone system& wittoutdlreetaligltol control of Individual zones communlealtng wllh,e central control panel. 3. Systems with a design outdoor airflow leas then 1200 can. 4. Spaces wMrs the supply draw rate minus any makeup or outgoing transteralr requirement is lees then 1200 ctn. 1413 Alr Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 lie r.ent of the design supply sires outside air to reduce or eliminate the need for mach anical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the connoted terminal equipment lucking eiraide economizer, at outside elr temperatures of 45 °F dry- btdb/40°F net-bulb and below. For this eetcutatl an, ell factors Induding solar and Internal load shall be the earns as those treed far peak load calculations, mstapt for the Outside temperatures. Exception: Water economizers using air- cooled heat rejection equipmenl may use a 35 dry-bulb outside air temperature for thin calculation. This exception Is limited to maximum of 20 tons per building. 14132 Documentation: Water ecenamlzerprans submitted for approval shell Include the fallowing information: 1. Maximum outside air conditions for which economizer Is sized to provide full cooling, 2. Design coding load to be provided by economizer of tide outside air condMon. 3. Heat rejection and terminal equipment performance data Including model number, Rewrote, amenity, entering and leaving temperature in full economlzercooled mode. 1413.3 integrated Operation: Air economizers shall be capable of providing =nee coding oven when addillonal mechanical cooling is required to meet the remainder of the cooing load Exceptions: • 1. Indhedual, direct expansion units Net nave a rated madly lest than 65,000 Blunt end use nonintegrated economizer" controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water. oolsdwater chillers with waterside economizer. 14174 Humidification: If an air economizer Is required ono cooling system for which humidification equipment Is to be provided to maintain minimum Indoor humidity levels, than the humidifier shall be of the adiabatic type (direct evaporative media or tog atomization typo). Exceptions: 1. Health care facilities where WAC 24a 320.525 allows only steam injection humidifiers In ductwork downstream of final Opera 1412.6 Canbuation Heating Equipment Controls: Combustion heating equipmentxdlh a capacity over 225,000 Btu ler shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air madame with no provisions for our recirculation to the central supply fan, 4. Nonadiebelic humidifiers cumulatively serving no more than 10% of a building's dlr economizer capacity as measured In cfm. This refers to the system ctm serving rooms with stand alone or duct mounted humldeler& 1414 Ducting Systems 1414.1 Seating: Duct work which Is designed to operate at pressures above 1f2 Ind water column static pressure shall be sealed in accordance with Standard R5- 18. Extent of sealing required is as follows: 1. Stella prossuro: 112 Inch to 2inchhon; seal transverse joints. 2 Static pressure: 2 inches to 3 Inches; salt all transverse joints and tongitumnal seems. 3. Static pressure: above 9 incites; seat all tranaveree joints. longitudinal seems end duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at atatt c pressures of 1 inch W.C. or greeter. 1414.2 Insulation: Ducts and plenums that are constructed and function as pert of the building envelope, by separating Interior space from exterior space, shall meal at applicable requirements of Chapter 13. These m quirementa include insulation inatelellon, moisture control, air leakage, and building envelope Insulation levels. Unheated equipment rooms with combuelion elr louvers must be isolated from the conditioned space by Insulating Interior surfaces to a minimu m of R -11 and any extanor envelope surfaces per Chapter 13. Outside air duels serving Individual supply sir unite with less than 2,800 efm of total supply air capacity shag be Insulated P. 005/006 EF CAE 4 50 gal storage 0.5a 0.71 50 to 70 gat storage 0.57 0.71 > 70 gal storage 0.55 0.70 MAR- 14- 2008(FRI) 14:12 All Seasons Heating & A/C (FAX) 5095757847 2008 Washin ton Sato Nonresidential Ene tl Code Com.11ence Form -Mechanical-Permit-Plans 3009 Waste olen Slaw Prontsakienalal energy Coos ccmaeance Forma III II M EGH -C' K nooses ,nay =O07 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified Wing condition not less than the values Shown lo Telee 14 -1A through 14.10. If a nalonatiy recognized certification program exists fare produ at covered in Tables 144A through 14.10, and It includes provisions for ved(kaeon and challenge of equipment efficiency ratings, than the product shall be limed In Ina certification Program- C3811-fired and of -fired forced air furnaces with Input relings > 225,000 Bluth (e5 kW) and aU unit healers shall also have an intermittent Ipndan orTnternrpted device (HD), and have either mechanical draft (including power venting) or nue damper. A vent damper Is on acceptable alternative to a due damper for furnaces where combustion aide drawn from the conditioned space Ni furnaces with Input ratirtgs 225,000 Bluth (85 kW), including electric furnaces, that are not healed within the conditioned space shall have Picket bsses not exceeding 175% of the Input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test condtions and procedures when mailable. Whore no applicable procedure erdet, dale shall be furnished by Inc equipment manufacturer. 1411.3 Combination Space and Sow Ice Water Heating: For combination space and service water healers with a principal function of providing apace heat. the CombinodAnnuol Efficiency (CAE) may be calculated by using ASHIiAE Standard 124 -1991. Storage water heaters used in combination space hest and water heel applcallon& Shall have either an Energy FAclor (EF) or or CAE of not lees than the following: 1411.4 Pecks equipment providing both healing and ceding with a total cooling capedly greater than 20, Bluth shell be a heat pump. Exception: Unstarfed equipment dwellers or cabinets used solely for pereonel wireteae service facilities. 1412 Controls 1412.1 Temperature Coetrolk: Each tyystem shall be prodded with at loast one temperature control devi e. Each nine shall be controlled by individual thermostatic =hole responding to temperature within the zone. Ala minimum, each floor of a building shall be considered as a separate zone, 14122 Deadband Controls: When used to caned both comfort healing and coaling, zone thermostatic controls shall be capable of a dee:hand or at lead 5 degrees F within which tho supply of healing and co ding energy to the zone la snit( oforteduced to a minimum. Exception's: 1. Special occupancy, spectre usage, or code requirements where deadband controls am not appropriate. 2 Buildings complying with Seethe 1141.4, If In the proposed building energy analysis, healing and cooling thermostat midpoints em set to the same temperature between 70 degrees P and 76 domino F Inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating end cooling modes. 14113 Humidity Controls: Ito system Is equipped with a means for adding mdature, a htnddiatet shell be provided. 14124 Setback and Shut -Off: HVAC systems shell be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day dock and he capable of being sat for seven different day typos per week. It must retain programming and time fora power loss of 10 hours and Include an accessible manual override al up to 2 hours. Exception: 1. Systems serving areas watch require continuous operation at the same temperature attune 2. EqulgmentwIth full load denude or2 kW (0.820 Dlulh) arises may be controlled by readily so:essible manual off hour control,. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant Is sensed fora period of up to 30 minutes. 4. Systems controlled solely by a manually operated Omer capable of operating the system for no more than two houra. 14124.1 Dampers Outside elr Intakes, edteust outlets end relief outlets oendng cotldItioned spaces shall be equipped with dampers which dose au tomailcellY when the system is off or upon power tenure. Star shall and elevator shalt smoke relief openings shall be equipped Witt normally open (lags to open upon toes al power) dampers These dampers sh ell remain dosed until activated by the fete a hum system or other approved smol® detection system. Exceptions: 1. Systeme serving areas which require continuous operation. 2. Combustion air Intakes. 3. Gravity (ramnotorizad) dampers are aocaptablo In buildings lees than 3 store= In height. . rete.e mummer GOTIVOla tar rage - uccupency Areas: teemarrt rantrul ventilation (OCV) Is required for spaces that ere larger than 500112, have a design occupancy for ventilation of greater than 40 people for 1000 1{2 of floor area, end are served by systems with one or more of the folioed = a An atr-slde,economlter, b. Automatic maculating control of the outdoor air damper. or e. A design outdoor airflow grader than 9000 cfm, Ere:options: 1.Syalame with energy recovery complying with Section 1438. 2. Multiple-zone system& wittoutdlreetaligltol control of Individual zones communlealtng wllh,e central control panel. 3. Systems with a design outdoor airflow leas then 1200 can. 4. Spaces wMrs the supply draw rate minus any makeup or outgoing transteralr requirement is lees then 1200 ctn. 1413 Alr Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 lie r.ent of the design supply sires outside air to reduce or eliminate the need for mach anical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the connoted terminal equipment lucking eiraide economizer, at outside elr temperatures of 45 °F dry- btdb/40°F net-bulb and below. For this eetcutatl an, ell factors Induding solar and Internal load shall be the earns as those treed far peak load calculations, mstapt for the Outside temperatures. Exception: Water economizers using air- cooled heat rejection equipmenl may use a 35 dry-bulb outside air temperature for thin calculation. This exception Is limited to maximum of 20 tons per building. 14132 Documentation: Water ecenamlzerprans submitted for approval shell Include the fallowing information: 1. Maximum outside air conditions for which economizer Is sized to provide full cooling, 2. Design coding load to be provided by economizer of tide outside air condMon. 3. Heat rejection and terminal equipment performance data Including model number, Rewrote, amenity, entering and leaving temperature in full economlzercooled mode. 1413.3 integrated Operation: Air economizers shall be capable of providing =nee coding oven when addillonal mechanical cooling is required to meet the remainder of the cooing load Exceptions: • 1. Indhedual, direct expansion units Net nave a rated madly lest than 65,000 Blunt end use nonintegrated economizer" controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water. oolsdwater chillers with waterside economizer. 14174 Humidification: If an air economizer Is required ono cooling system for which humidification equipment Is to be provided to maintain minimum Indoor humidity levels, than the humidifier shall be of the adiabatic type (direct evaporative media or tog atomization typo). Exceptions: 1. Health care facilities where WAC 24a 320.525 allows only steam injection humidifiers In ductwork downstream of final Opera 1412.6 Canbuation Heating Equipment Controls: Combustion heating equipmentxdlh a capacity over 225,000 Btu ler shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air madame with no provisions for our recirculation to the central supply fan, 4. Nonadiebelic humidifiers cumulatively serving no more than 10% of a building's dlr economizer capacity as measured In cfm. This refers to the system ctm serving rooms with stand alone or duct mounted humldeler& 1414 Ducting Systems 1414.1 Seating: Duct work which Is designed to operate at pressures above 1f2 Ind water column static pressure shall be sealed in accordance with Standard R5- 18. Extent of sealing required is as follows: 1. Stella prossuro: 112 Inch to 2inchhon; seal transverse joints. 2 Static pressure: 2 inches to 3 Inches; salt all transverse joints and tongitumnal seems. 3. Static pressure: above 9 incites; seat all tranaveree joints. longitudinal seems end duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at atatt c pressures of 1 inch W.C. or greeter. 1414.2 Insulation: Ducts and plenums that are constructed and function as pert of the building envelope, by separating Interior space from exterior space, shall meal at applicable requirements of Chapter 13. These m quirementa include insulation inatelellon, moisture control, air leakage, and building envelope Insulation levels. Unheated equipment rooms with combuelion elr louvers must be isolated from the conditioned space by Insulating Interior surfaces to a minimu m of R -11 and any extanor envelope surfaces per Chapter 13. Outside air duels serving Individual supply sir unite with less than 2,800 efm of total supply air capacity shag be Insulated P. 005/006 MAR- 14- 2008(FRI) 14:12 All Seasons Heating & A/C (FAX) 5095757847 P.006/006 2. Combustion air Intakes. 2006 WashIngton State Nonresidenti6tb fibidi ealdtsyyQuirlpgtpliUMFOLRbcas toe minlmu m of R -11 and any wiener envelope outfaces per Cheater 13. 011121d0 air ducts serving individual supply air units with lass than 2,100 dm of tenet supply air capacity ahell be insulated to a minimum of R.7 and am not conoldered building envelope. Other outside air duet tuns are considered building envelope until troy, 1. connect to the heeling or cooing ocuicrnenL ar 2. ere isolated from the er4erierwilh on automatic shut-off damper oomplying with Section 1412.4.1. Once outside air duels meal the above listed requirements, any funs within conditioned apace shall comply with Table 14 requirements. Other ducla and plenums shall be Ularmelly insulated per Table 14 4. EacepCons: 1. 1Mlhin the HVAC equipment. 2. Exhaust air duct& not subject to pondensaion. 3. Exposed ductwork within a zone that serves that cone. 1418 Piping Systems 1415.1 Insulation: Piping shall be thermally Insulated In accordance With Table 14 .8. Exception: Piping Installed within unitary HVAC equipment. Waterplpes outside the conditioned apace shall be Insulated In acrordonca with Washington State Plumbing Code (WAC 51 -28) 1416 Completion Requirements (Refer to NREC Sedan 1416 and rho Beading Commissioning Guidelines, pubilsnod by the Building Commissioning Aacoclation, for complete teal and guidelines tor banding completion and commissioning requirements.) 3. GraNly (nonmolorlsed) dampen are acceptable In buildings lass than 3 eloftea in height. 4. gravity (nonmolorted) dampers are acceptable In exhaust and relief oulkla in the first story and levels below the first story of buildings three or more modes in height. 14124.2 Optimism Start Controls: Healing and mating systems with design apply air capacities exceeding 10.000 dm shall have optimum sten controls. Optimum start centrals shell be demigned to automaUcatly adjust the maritime of an HVAC system each day to bring the specs to desired occupied temperature lavele immediately before scheduled occupancy. The control algorithm shell. as a minimum, be a funcUen or the differenca between apace temperature and occupied aetpdnt and the amount of time prior le scheduled occupancy. 1412.6 Host Pump Controls: Unifaryair cooled heat pumps shell Include microprocessor controls that minimize supplemental heat usage during etatf.0 p, sett- ee, and deftest Conhiticn& Those controls shall anticipate need for heal and use comproeaiari healing es the feat stage of heal Controls shall indicate When supplemental heating is being used through vieurtl moans (e.g.. LED Indicators). 1412.6 Combustion Healing Equipment Controls: Combustion heating equipment with a capacity over 225.000 Btulhshell have modulating or staged combustion contra 000 EXCEPTIONS: 1. Boilers. 2. Radiant heaters. 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have B meant for balancing. Including but not limited to, dampers. temperature and poseurs teat connections and balancing valves. ACTIVITY NUMBER: M08 -088 PROJECT NAME: JUST SPORTS SITE ADDRESS: 2467 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # DATE: 03 -21 -08 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: AIN Building Division Public Works Ti Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 03-25-08 Complete Comments: TUES/THURS R UTING: Please Route rvz REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 + PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP 1 50AWc' '1 - 1—o Fire Prevention Incomplete DATE: Ti Permit Coordinator DATE: Planning Division Not Applicable Structural Review Required I No further Review Required Ti DUE DATE: 04 -22 -08 Not Approved (attach comments) n ► �� n Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License ALLSEHA265Q2 Licensee Name ALL SEASONS HTNG /AIR CON INC Licensee Type CONSTRUCTION CONTRACTOR UBI 600142809 Ind. Ins. Account Id #5 Business Type CORPORATION Address 1 PO BOX 9006 Address 2 City YAKIMA County YAKIMA State WA Zip 989090006 Phone 5095220672 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 11/22/1974 Expiration Date 3/20/2010 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date POE, TERRANCE L Cancel Date 01/01/1980 Bond Amount Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #5 TRAVELERS CAS & SURETY CO 200366036 11/22/2001 Until Cancelled $12,000.00 11/21/2001 TRAVELERS Look Up a Contractor, Elect an or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. 1 Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= ALLSEHA265Q2 04/16/2008 TAG MAKE MODEL VOLTS PHASE CFM SP KW STEPS INLET DISCHARGE T13-1 TITUS DE 480 3 1400 1 10 2 12" IRND 15/16 TB -2 TITUS DESV . 480 3 1500 1 10 2 12" IRND 15/16 HVAC PLAN 1/4" = 1' - 0" N otes : 1) Thermostat to be Carrier commercial 7 day programmable with 5 dead -band capability. 2) Ventilation fans to be installed as per Washington state ventilation code and indoor air quality code CHP 51 -13 WAC. 3) All air supply openings to be provided with balancing dampers. Location as indicated on the drawings. 4) All ductwork to be installed inside the conditioned space. NO insulation required as per WSEC Chapter 5, Table 5 -11. 5) Balance the air per WSEC Section 1416.2.2.2. 6) Conimissicn the systems using factory recommended procedures for the controls and HVAC equipment and per WSEC Section 1416.2 EQUIPMENT SCHEDULE DUCT MOUNTED SMOKE DETECTOR CONNECT TO MALL SYSTEM 8/8 100 MCD 20"0 N ` TB -1 12 "o \� 12/12 TD 350 FM C 10"0 12/12 350 FM 12 "0 12/12 TDC CFM 12/12 TDC 12/12 350 CFM NORTH Your Local Carrier Dealer ALL SEASONS HEATING & AIR CONDITIONING, INC. Mail: P1O1Box 9006 Yakima WA 98909-9006 office: 302 South 3rd Ave. Yakirna WA 98902 Phone: (509) 248 -6380 FAX: (509) 575.7847 www.allseasonsheating.com WA# ALLSEHA265Q2 OR# 137859 can < ce awn J CO mils 0 cn c-) w D w 0 SCALE: 1/4" 1'0" BY: Robert H. Rhines REV. #1.0 DATE: 2-29-2008 By 0 SEPARATE PERMIT REQUIRED Q ical Electrical 1 Plumbing Gas Piping City of Tukwila IBUILIOING D S1 -N I FILE COPY Permit No. Par review approval Is sublect does Approval of �� ordinance. Receipt the violation of any 0 aPorcNed Field Copy and mullions is acknowledged: City of Tukwila BUILDING DIVISION REVISIONS shall be made to the el c No changes prior of work without p approval Tukwila Building Div NOTE: Revisions will require a new plan submittal n tees. and may include additional plan review RECEIVED MAR 212008 PERMIT CENTER