Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M08-091 - WESTFIELD SOUTHCENTER MALL - WET SEAL
WET SEAL 2446 SOUTHCENTER MALL M08 -091 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: SOUND HEATING & A/C INC Address: 5209 122 ST E , TACOMA, WA Contractor License No: SOUNDHA066BM DESCRIPTION OF WORK: NEW VAV SYSTEM FOR TI 6364200010 2446 SOUTHCENTER MALL TUKW Value of Mechanical: $30,000.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC -10/06 Cityillf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us WET SEAL 2446 SOUTHCENTER MALL , TUKWILA WA WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD CA REBECCA MILSTER 1950 CRAIG RD STE 300 , ST LOUIS MO MECHANICAL PERMIT Fees Collected: $567.50 International Mechanical Code Edition: 2006 EQUIPMENT TYPE AND QUANTITY 1 0 0 0 0 0 1 0 0 0 0 0 0 0 * * continued on next page ** M08 -091 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 800 - 489 -2233 Phone: 253 - 535 -6249 Expiration Date: 08/15/2009 M08 -091 06/02/2008 11/29/2008 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 06 -02 -2008 Permit Center Authorized Signature: doc: I MC -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: M08 -091 Issue Date: 06/02/2008 Permit Expires On: 11/29/2008 Date V U I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does no p - sume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the rm. • e • • • rk. I am authorized to sign and obtain this mechanical permit. Signa � � /l Date: Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M08 -091 Printed: 06-02 -2008 Parcel No.: 6364200010 Address: 2446 SOUTHCENTER MALL TUKW Suite No: Tenant: WET SEAL 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: M08 -091 Status: ISSUED Applied Date: 03/27/2008 Issue Date: 06/02/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: ** *FIRE DEPARTMENT CONDTITONS * ** 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 13: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 14: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 15: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) doc: Cond -10/06 M08 -091 Printed: 06-02 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 17: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 18: An electrical permit from the City of Thkwila Building Department Permit Center (206- 431 -3670) is required for this project. 19: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 20: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 21: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** M08 -091 Printed: 06-02 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: � �1 Date: HA /1 i< Q Print Name: doc: Cond -10/06 M08 -091 Printed: 06-02 -2008 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Building Permit No. Project No. _ Mechanical Permit No. � NC -_ 0 q Plumbing/Gas Permit No. (0 ;)- 0 Public Works Permit Ho OS- OV (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION 1 �� �,� King Co Assessor's Tax No.: (6344)-0 - 0 ct) / Site Address:" S " 0 lAM r t CQ VlY 1 ' y , 1Ca \,\ Tia. (� (k\ Suite Number Floor: 5 VS Tenant Name: # S New Tenant: igt Yes ❑..No Property Owners Name:_• 7 S%\ -- (Ac\. C h t� 1.1 � it 1 0 �.., Mailing Address: .2-L ip S o AVI CQ Vl-1V CV∎ack A CONTACT PERSON - who do we contact when your permit is ready to be issued Name: Company Name: Company Name: Mailing Address: Contact Person: E -Mail Address: Company Name: Mailing Address. Contact Person: E -Mail Address: T-ebecca 1 B prC J i si OY- Inc.. 1 c1 r O Cr -aa t . Ske . 30 - e62ccA m t kSielr rry4s. e -moo aYf.r/. ce ►M jorcVi s %- Tr%c. cI.c 0 Crcj Zk 3c o tZQbe up. 1 Mete r 1Nke O.J. 4, Q:\ Applications \Fonns- Applications On Line'3 -2006 - Permit Application.doc Revised: 9 -2006 bh City Day Telephone: sf-4300 St. co va:s Mailing Address:_)3 SO Ceaa3 E -Mail Address: O C..\J. (to, Contact Person: E -Mail Address: Contractor Registration Number: City Fax Number: S+. lets City Day Telephone: Fax Number: W P, State 5+. L43 5 010 Bo c a-.)-33 State State Zip City State Zip Day Telephone: 800 - "lac) - 2a 33 Fax Number: 314 — ,2 3 Zip NO [03 L aP State Zip 3 ' 415 2300 GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Mailing Address: City Day Telephone: Fax Number: Expiration Date: Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record 010 1.031 (ilp 800 Vgq - aa.33 3N- 415 -23o0 ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Page 1 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU ,s Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 9 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat x 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System S Incinerator - Domestic Other Mechanical Equipment \ I V SiS M x Air Handling Unit <10,000 CFM )( Incinerator — Comm/Ind MECHANICAL PERMIT INFORMATION - 206 - 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: Tt) Mailing Address: City State Zip Contact Person: _ Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $ 303 0 00 Scope of Work (please provide detailed information): \ AV S 5Tie r i 1 t. 5 pcLui Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ❑ Replacement ....N Fuel Type: Electric 1 Gas .... Other: Indicate type of mechanical work being installed and the quantity below: Q: ApplicationsTonns- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Page 4 of 6 • • PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHO ZED AGENT: Signature: Print Name: - i e ccz Date Application Accepted: Q:\ApplicationsWorms- Applications On LineO -2006 - Permit Application.doc Revised: 9 -2006 bh Date: 3-69 —08 Day Telephone: 8o 0 %I - 3-d-3 3 Mailing Address: (t S (,Yz 2� R: � a 0 S+• LbL�� s 'I a r0 (42 31 (l o J City State Zip Date Application Expires: .. Staff Initials: L^ Page 6 of 6 Payee: THEODORE HANKE ACCOUNT ITEM LIST: Description MECHANICAL - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1527 466.00 RECEIPT Parcel No.: 6364200010 Permit Number: M08 -091 Address: 2446 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 03/27/2008 Applicant: WET SEAL Issue Date: Receipt No.: R08 - 01884 Payment Amount: $466.00 Initials: WER Payment Date: 06/02/2008 11:29 AM User ID: 1655 Balance: $0.00 Account Code Current Pmts 000.322.102.00.0 466.00 Total: $466.00 3121 06/02 9711 TOTAL 46600 doc: Receiot -06 Printed: 06 -02 -2008 Receipt No.: R08 - 00938 Payee: ARCVISION INC ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: M08 -091 Address: 2446 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 03/27/2008 Applicant: WET SEAL Issue Date: Initials: WER Payment Date: 03/27/2008 01:31 PM User ID: 1655 Balance: $406.00 TRANSACTION LIST: Type Method Descriptio Amount Payment Check 16277 101.50 Account Code Current Pmts 000/345.830 101.50 Total: $101.50 Payment Amount: $101.50 3 �{ 1 doc: Receiot -06 Printed: 03 -27 -2008 Project 1 W S&A Type of Inspection: I C\rN I Address: 2L ,mal Date Called: Special Instructions: Date Wanted:: I 7— 2_ -f - (f a.m. p.m. Requester: Phone No: 3 INSPECTION RECORD Retain a copy with permit l� 0� INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tuk ila, WA 98188 (206)431 -3f 7 - Approved per applicable codes. Corrections required prior to approval. COMMENTS: ?e(.4, Cl rcv" p Date: 7 -74 - 00. ❑ $60. u REINSPECTION F REQUIRED. Prior to inspection, fee must be pai . at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: r.r�_ .... Lra.r.....a�_..�R.rs.1...�..wt .riW��aNm''a1H111� .nw.e-.o-.ir..d 0103sIAA COMMENTS: r• 1l I V — I I I �w A 444)0 Viv . ! if Co " e }flt 4-4.5 0 0144 Liqc. - - - Z e V .,�+k r i1 x-A V �� s ,, t ® ® <re-t.,e-C W WI%k t4c. -2,4 is k 4-- .JL'o• (� irk 0 rime- 9u4A- A Address: Z4 L 6 r Date Called: Special Instructions: Date Wanted: '7 i D a.m. / p.m. Requester: Phone "..26: ? 6 a G 2+ INSPECTION RECORD Retain a copy with permit og INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 12 " 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ,4pproved per applicable codes. El Corrections required prior to approval. Inspecto Date: � 5 /eq- ❑ $60.00 REINSPECTION FEE RE?]UIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION RECORD Retain a copy with permit og INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 12 " 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ,4pproved per applicable codes. El Corrections required prior to approval. Inspecto Date: � 5 /eq- ❑ $60.00 REINSPECTION FEE RE?]UIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: COMMENTS: n Type of Inspection:_, J 4 Address: Li L ite il/ a Skil e ele 7 re .n4 ce i latAiil - fcS7 4- 4/44:5 he cLe i /tP /cam' Drd 1 dd' d P . 'x16, t r Phone No: 2'5:3 / O4 5-9,2Y Project: P t �f1 n Type of Inspection:_, J 4 Address: Li L ite il/ a Date Called: Special Instructions: Date Wanted: / O ro.. /�� Requester: Phone No: 2'5:3 / O4 5-9,2Y INSPECTION NO. Inspector: INSPECTION RECORD Retain a copy with permit r, PERMIT NO. CITY OF TUKWILA BUILDING DIVISION x 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 D Approved per applicable codes. RI Corrections required prior to approval. ( Date: 7//if/4 y El $60.00 RF,1 SPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 63 0 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Proje •t: i Type o Inspectio : . Add r j M 4 /� Date Called: Special Instructions: Date Wanted: � � ` V m Requester: Phone No: 25-3 - 606 - 5 - 52 y i • mpg --fit/ INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION A. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: / ( / 422 - eckvv CweP,l " Date: /if S p $60. c INSPECTION FEE REQUIRED. Prior to inspection, fee must be paid 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: !Date: Project: k) $_ L-- Sprinklers: Fire Alarm: Hood & Duct: Type of I spection: -4 i i erg Address: Suite #: LI` (e3 s 6 "-' Contact P rson: Special Instructions: / / / Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER n i I I Apprved,.per applicable codes. Word /Inspection Record Form.Doc 1/13/06 INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT Pei 15 G' — c g? PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Corrections required prior to approval. COMMENTS: r Inspector: Date: 7// 9/a7' Hrs.: ( rs.. $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. T.F.D. Form F.P. 113 Fan Equipment Schedule Equip. ID Brand Name' Model No. CFM SP' HP /BHP Flow Control Location of Service VAV -1 TRANE VPEF1200Q 1890 4KW 1/3 HP VAV PLENUM VAV -2 TRANE VPEF1200Q 1890 VPEF1200Q 1/3 HP VAV PLENUM PLENUM M O9o 9i Cooling Equipment Schedule Equip. ID Brand Name Model No. Capacity Btu /h Total CFM OSA CFM or Econo? SEER or EER IPLV Location VAV -1 TRANE VPEF1200Q 4KW 1890 545 5 - Fill out this line on PRJ -SUM PLENUM VAV -2 TRANE VPEF1200Q 4KW 1890 545 PLENUM Heating Equipment Schedule Equip. ID Brand Name Model No.' Capacity Btu /h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency VAV -1 TRANE VPEF1200Q 4KW 1890 545 5 - Fill out this line on PRJ -SUM Applicant Phone: VAV -2 TRANE VPEF1200Q 4KW 1890 545 Project Info Project Address SOUTHCENTER MALL Date 3/26/2008 1056 SOUTHCENTER For Building Dept. Use SEATTLE, WASHINGTON 98188 Applicant Name: WET SEA Applicant Address: 5 - Fill out this line on PRJ -SUM Applicant Phone: 6 - Fill out this line on PRJ -SUM i - 11FVTFIA/FIM Pfl 2006 Washington State Nonresidential Energy Code Compliance Form ech an! '. "x?iSstj! , 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Description Briefly describe mechanical system type and features. ❑ Includes Plans Compliance Option FILE COPY Include documentation requiring compliance with commissioning requirements, Simple System U Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM fo CODE COMPUA APPROVED APR 14 2008 ection 1416. Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). ICE D 08 1 1f available. 2 As tested according to Table 14 -1A through 14-1G. 3 If required. ° COP, HSPF Combustion Efficiency, o PARWIT CENTER System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling or Cooling Only: ❑ Constant vol? ❑ Split system? ❑ Air cooled? ❑ Packaged sys? ❑ <20,000 Btuh? ❑ Economizer included? If Heating Only: 9 Y� ❑ <5000 5000 cfm? = <70% <70 /o outside air? 2006 Washington State Nonresidential Energy Code Compliance Form . YS umrr an,ca t .y . ac Decision Flowchart v Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. <5000 cfm? Use Complex Systems (section 1430) Econo ncluded? Simple System Allowed (section 1420) ingle split Syste Package N. <= 84,000 Unit? Btuh? Air Cooled, Constant Vol? otal Cap. wo economizer <240,000 Btuh or 10 %? Outd. or Adjacent to • utdoors' ool Ca <54,000 Btuh? System Type Heating Only Yes - <70% OSA }-Yes* Reference Section 1421 A'J $J ST- Heating /Cooling or Cooling Only Yes Yes Yes Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. ;a:1 u 1�$ }S'f�r�t M ec ha nical 2006 Washington State . tn ,� � a � '. t +f:,.. { .�• . a,a !i t f J i a ^ 1. GS t i - r � S�+ � j K ;PerrnitLP{Ians�YClhe �t ;� a { ,� ry } �� +' i t< . . -x. ....l.M' G � c�.. - .P LC. •,�...- .w +?v J_,L,,,,.„:r•t..T y .Y_tt•.. -.SIt YsY.! .�..'i. :. �9..Sv'�M x ,. NS,F. .X tr'_ Y . a .. Nonresidential Energy Code Compliance Forms i' � ?' ; { ��G °MECH,CHI ... ,.•... .'.._ _.Z:.t.. F -. F.r1.4x' Revised July 2007 Project Address SOUTHCENTER MALL 'Date 3/26/2008 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance n.a. 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule n.a. 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency n.a. 1411.1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket loss 1412 HVAC controls yes 1412.1 Temperature zones Indicate locations on plans yes 1412.2 Deadband control Indicate 5 degree deadband minimum n.a. 1412.3 Humidity control Indicate humidistat yes 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types yes 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage n.a. 1412.4.2 Optimum Start Indicate optimum start controls . - n. a. 1412.5 Heat pump control Indicate microprocessor on thermostat schedule n.a. 1412.6 Combustion htg. Indicate modulating or staged control yes 1412.7 Balancing _— Indicate balancing features on plans 1412.8 Ventilation Control Indicate demand control ventilation for high- occupancy areas n.a. 1422 Thermostat interlock Indicate thermostat interlock on plans n.a. 1423 Economizers Equipment schedule 1413 Air economizers n.a. 1413.1 Air Econo Operation Indicate 100% capability on schedule n.a. 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb n.a. 1413.2 Water Econo Doc Indicate clg load & water econoe & clg tower performance n.a. 1413.3 Integrated operation Indicate capability for partial cooling h. a. 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems yes 1414.1 Duct sealing Indicate sealing necessary yes 1414.2 Duct insulation Indicate R -value of insulation on duct n.a. 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Completion Requirements yes 1416.2.1 Commissioning Provide commissioning plan yes 1416.2.2 -3 Sys.Bal & Func.Test Indicate air and water system balancing & functional testing yes 1416.2.4 Commissioning Indicate O &M manuals, record drawings, staff training yes 1416.2.5 Comm. Report Indicate requirements for prelim. & final commissioning report yes 1434 ' Separate air sys. Indicate separate systems on plans yes Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. yes 1441 Elec. water heater Indicate R -10 insulation under tank yes 1442 Shut -off controls Indicate automatic shut -off yes 1443 Pipe Insulation Indicate R -value of insulation on piping n.a. 1452 Heat Pump COP Indicate minimum COP of 4.0 n.a. 1452 Heater Efficiency Indicate pool heater efficiency n.a. 1453 Pool heater controls Indicate switch and 65 degree control n.a. 1454 Pool covers Indicate vapor retardant cover n.a. 1454 Pools 90+ degrees Indicate R -12 pool cover 2006 Washington State Nonresidential Energy Code Compliance Form no is circled for any question, provide explanation: 2006 Washington State Nonresidential Energy Code Compliance Form ec.hani Ii � 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14 -1G. If a nationally recognized certification program exists for a product covered in Tables 14 -1A through 14 -1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings > 225,000 Btu /h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings > 225,000 Btu /h (65 kW), including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 141'1.4 Packaged Electric Heating and Coo ing Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu /h shall be a heat pump. Exception: Unstaffed equipment shaelt4rs or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual off-hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity ( nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings three or more stories in height. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply 1412.8 Ventilation Controls for High- Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry - bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu /h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246 - 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut -off damper complying EF CAE < 50 gal storage 0.58 0.71 50 to 70 gal storage 0.57 0.71 > 70 gal storage 0.55 0.70 2006 Washington State Nonresidential Energy Code Compliance Form ec.hani Ii � 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14 -1G. If a nationally recognized certification program exists for a product covered in Tables 14 -1A through 14 -1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings > 225,000 Btu /h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings > 225,000 Btu /h (65 kW), including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 141'1.4 Packaged Electric Heating and Coo ing Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu /h shall be a heat pump. Exception: Unstaffed equipment shaelt4rs or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual off-hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity ( nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings three or more stories in height. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply 1412.8 Ventilation Controls for High- Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry - bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu /h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246 - 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut -off damper complying system each day to bring the space to desired occupied temperature levels immediately before scheduled occupancy. The control algorithm shall, as a minimum, be a function of the difference between space temperature and occupied setpoint and the amount of time prior to scheduled occupancy. 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start -up, set- up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shall indicate when supplemental heating is being used through visual means (e.g., LED indicators). 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu/h shall have modulating or staged combustion control. 000 EXCEPTIONS: 1. Boilers. 2. Radiant heaters. 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have a means for balancing, including but not limited to, dampers, temperature and pressure test connections and balancing valves. • 2006 Washington State Nonresidential Energy Code Compliance Form 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply 2. are isolated from the exterior with an automatic shut -off damper complying air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum with Section 1412.4.1. start controls shall be designed to automatically adjust the start time of an HVAC Once outside air ducts meet the above listed requirements, any runs within conditioned space shall comply with Table 14 -5 requirements. Other ducts and plenums shall be thermally insulated per Table 14 -5. Exceptions: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a zone that serves that zone. 1415 Piping Systems 1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14 -6. Exception: Piping installed within unitary HVAC equipment. Water pipes outside the conditioned space shall be insulated in accordance with Washington State Plumbing Code (WAC 51 -26) 1416 Completion Requirements (Refer to NREC Section 1416 and the Building Commissioning Guidelines, published by the Building Commissioning Association, for complete text and guidelines for building completion and commissioning requirements.) ACTIVITY NUMBER: M08 -091 DATE: 04 -22 -08 PROJECT NAME: WET SEAL SITE ADDRESS: 2446 SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 After Permit Issued DEPARTMEN S: Bui ng" Division Public Works DETERMINATION OF i OMPLETENESS: (Tues., Thurs.) Complete Comments: • • PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP iL Ala. Fire Prevention Structural Incomplete Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROYITING: Please Route REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 Structural Review Required Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: Planning Division n Permit Coordinator DUE DATE: 04 -24 -08 ❑ No further Review Required DATE: DATE: Not Applicable DUE DATE: 05 -22 -08 Not Approved (attach comments) n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: M08 -091 DATE: 03 -27 -08 PROJECT NAME: WET SEAL SITE ADDRESS: 2446 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: T1 IO O Bui d Public Works Please Route Approved Notation: Documents/routing slip.doc 2 -28 -02 • • PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP Di ision DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: 1 1 Structural Structural Review Required Approved with Conditions yfI Al4)i, 3 rr., 1 4 Fire Prevention Planning Division n Permit Coordinator DUE DATE: 04 -01-08 Not Applicable n No further Review Required DUE DATE: 04-29-08 Not Approved (attach comments) REVIEWER'S INITIALS: DATE: 1.i Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: ❑ Response to Incomplete Letter # ❑ Response to Correctio,n Letter # ! Revision # l - Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: (A) J Project Address: Z/ 3o h 4Ce Contact Person: Pe ep /ft , s Phone Number: eo 0 - 3 Summary of Revision: l l J Rte; si o-1 S b Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: L tEr Entered in Permits Plus on _1 lapplications\forms- applications on Iinelrevision submittal Created: 8 -13 -2004 1 0 2- (D • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: /fwww.ci.tukwila.wa.us } Plan Check/Permit Number: To k -01 Steven M. Mullet, Mayor Steve Lancaster, Director RECEIVED CITV0 F.Tl.3MRI 2 III i1 *MS calm License Information License SOUNDHA066BM Licensee Name SOUND HEATING & A/C INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601479795 Ind. Ins. Account Id 57759001 Business Type CORPORATION Address 1 5526 184TH STREET E Address 2 City PUYALLUP County PIERCE State WA Zip 98375 Phone 2538753350 Status ACTIVE Specialty 1 HTGNENT /AIR CONDITIONING Specialty 2 UNUSED Effective Date 1/14/1994 Expiration Date 8/15/2009 Suspend Date Separation Date Parent Company Previous License SOUNDHC112N2 Next License Associated License Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #5 CBIC SC2727 08/03/2001 Until Cancelled $6,000.00 07/10/2001 #4 CBIC SC2727 08/14/1999 08/03/2001 $4,000.00 Business Owner Information Name Role Effective Date Expiration Date HOOD, CURTIS C 01/01/1980 HOOD, RANDY A 01/01/1980 Look Up a Contractor, Electrician or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= SOUNDHA066BM 06/02/2008 AIR DEVICE SCHEDULE e PLAN MODEL NO. *TITUS FACE NECK FLEX VPEF1200Q (PARALLEL FAN POWERED) 545 MARK QTY. MODEL NO. SIZE SIZE SIZE TYPE NOTES A 7 TDCA- 3/AG -95 24 "x24" 10"0 10 "0 DIFF. 1,2,3,5,6 B 1 TDCA- 3/AG -95 24 "x24" 12' 12 "0 DIFF. 1,2,3,5,6 c 1 TDCA- 3/AG -95 24 "x24" 10' 10 "e DIFF. 1,2,4 D 1 TDCA- 3/AG -95 24 "x24" 8 1 '0 8 "0 DIFF. 1,2,4 E 3 50 F 24 "x24" 22 "x22" N/A R.A.G. 4 F 3 50 F 24 "x24" 22 "x22" N/A R.A.G. 3,5,6 NOTES: 1. REFER TO PLAN FOR THROW PATTERN 2. PROVIDE AND INSTALL MANUAL VOLUME DAMPER 3. FRAME SHALL FIT GYP. BD. ROUGH —IN OPENING 4. FRAME SHALL FIT LAY —N CEIUNG MODULE 5. CONTRACTOR SHALL COORDINATE REQUIRED ACCESSORIES AND INSTALLATION WITH LOCAL "TITUS" REP. PRIOR TO ORDERING AND INSTALLATION OF AIR DISTRIBUTION SYSTEM. 6. TRM FRAME (TO BE UTILIZED AS ACCESS PANEL ABOVE CEILING WHEN REQ'D.) VAV BOX SCHEDULE (VAV -1 -I- VAV -2) MANUFACTURER MODEL NO. MINIMUM AIR CFM TOTAL CFM INLET SIZE TRANE VPEF1200Q (PARALLEL FAN POWERED) 545 1,890 12" DISCHARGE SIZE ELEC. HEAT BASE UNIT WEIGHT FAN SIZE FAN HP FLA 20 "x16" 4.0 KW 0 460 V, 3 PH 96 LBS 03SQ 1/3 © 277V, 1 PH 1.6 LANDLORD NOTES DO NOT ATTACH ANYTHING DIRECTLY TO SLAB OR ROOF DECK ABOVE. TENANT SHALL MAINTAIN A MINIMUM OF 6" UNOBSTRUCTED CLEARANCE HEIGHT IN RETURN AIR PLENUM ABOVE CEIUNG ALLOWING FOR AIR FLOW BACK TO LANDLORD'S AIR CONDITIONING UNIT. LANDLORD PROVIDED A TENANT FIRE SERVICE MAIN WITH BRANCH PIPING STUBBED INTO EACH TENANT'S SPACE. LANDLORD'S SPRINKLER SYSTEM I5 DESIGNED PER ORDINARY HAZARD GROUP 2 AND THE LATEST REQUIREMENTS OF NFPA -13. NO ISOLATION VALVES WILL BE PROVIDED OR PERMITTED. TENANT SHALL CONNECT A FIRE SPRINKLER SYSTEM TO LANDLORD'S SPRINKLER SYSTEM WITHIN THE DEMISED PREMISES USING APPROVED MECHANICAL FITTINGS. TENANT SHALL PROVIDE AND INSTALL ALL BRANCH PIPING AND SPRINKLERS REQUIRED TO COMPLETE THE SPRINKLER SYSTEM WITHIN THE TENANT SPACE. TENANT'S SPRINKLER SYSTEM DESIGNS SHALL BE BASED UPON THE REQUIREMENTS OF THE STATE OF WASHINGTON, CITY OF TUKWILA FIRE DEPT. TENANT SHALL ENGAGE THE SERVICES OF A LANDLORD PREFERRED FIRE SPRINKLER CONTRACTOR TO DESIGN, PERMIT, AND INSTALL TENANT'S FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH THE BASE BUILDING DESIGN SPECIFICATIONS. SPRINKLER LAYOUT AND AND PIPE SIZING SHALL BE HYDRAULICALLY DESIGNED ACCORDING TO ORDINARY HAZARD GROUP 2 AND THE LATEST REQUIREMENTS OF NFPA -13. ALL SPRINKLER HEADS IN THE FORWARD SELLING AREA ARE TO BE CONCEALED POP OFF COVER TYPE. ALL SUPPORTS SHALL BE FROM STRUCTURAL BEAMS AND JOISTS, NOT FROM FLOOR OR ROOF DECK ABOVE. TENANT'S CONTRACTOR SHALL INSTALL AN INSPECTORS TEST CONNECTION, PIPED TO A FUNNEL DRAIN, (WITH WET TRAP), MOUNTED 3' -0" A.F.F.. INSTALL A 1" CORROSION RESISTANT SHUT—OFF VALVE. TENANT SHALL INSTALL A VANE TYPE WATERFLOW DETECTOR IN THE MAIN SPRINKLER LINE IMMEDIATELY AFTER CONNECTION TO THE LANDLORD'S MAIN, WHICH IS CONNECTED TO THE LANDLORD'S FIRE ALARM SYSTEM. * OR APPROVED EQUAL O HVAC -I- SPRINKLER KEYED NOTES 0 O NEW VAV COMPATIBLE THERMOSTAT SUPPLIED AND INSTALLED BY HVAC CONTRACTOR. (TYPICAL OF 2). COORDINATE WITH ELECTRICAL CONTRACTOR. MOUNTING HEIGHT 4' —O" A.F.F. PROVIDE LOCKING LUCITE COVER. TURN KEY OVER TO STORE MANAGER. ® COMBINATION EXHAUST FAN /LIGHT SUPPLIED & INSTALLED BY HVAC CONTRACTOR (TYPICAL OF 2). TEIBER MODEL #TFL9OL, 4 "0 DUCT SIZE, 165 W, 90 CFM, 2.0 SONES, 120v/1 ph /60hz. PROVIDE BACKDRAFT DAMPER. EXTEND AND CONNECT TO LANDLORD'S TOILET EXHAUST DUCT STUB —IN. FIELD VERIFY EXACT SIZE AND LOCATION. IF NO EXISTING LANDLORD EXHAUST DUCT, PROVIDE NEW TOILET EXHAUST DUCT THRU ROOF AS REQUIRED. MAINTAIN 10' -0" MIN. AWAY FROM ANY OUTSIDE AIR INTAKES. VERIFY IN FIELD. ® PROVIDE & INSTALL NEW SPRINKLER HEAD ON TOILET ROOM CEILING (TYPICAL OF 2). COORDINATE EXACT LOCATION WITH LIGHT /FAN FIXTURE. MODIFY SUPPLY PIPING AS REQUIRED. O PROVIDE NEW OR RELOCATE EXISTING SPRINKLER HEAD AS REQUIRED TO ACCOMMODATE NEW GYP. BD. CEILING (TYP.). COORDINATE EXACT LOCATION WITH NEW CEIUNG FIXTURES AND LIGHTS. MODIFY SUPPLY PIPING AS REQUIRED. ® NEW 2A -20B:C FIRE EXTINGUISHER PROVIDED AND INSTALLED BY GENERAL CONTRACTOR. COORDINATE EXACT QUANTITY AND LOCATION(S) WITH LANDLORD AND LOCAL FIRE MARSHALL. L/ APPROXIMATE LOCATION OF EXISTING SPRINKLER SYSTEM MAIN. FIELD VERIFY EXACT SIZE AND LOCATION. O NEW 2.5" THICK (R -7) EXTERNALLY INSULATED LOW PRESSURE SUPPLY AIR DUCT SUPPLIED AND INSTALLED BY HVAC CONTRACTOR (TYPICAL OF 2 HVAC SYSTEMS). PROVIDE TRANSITIONS AS REQUIRED, DUCT DIMENSIONS ARE CLEAR INTERNAL AIR PATH DIMENSIONS. HOLD ALL DUCTWORK AS HIGH AS POSSIBLE AND /OR PRACTICAL IN JOIST SPACE. ® CONTRACTOR TO ENSURE DOOR IS UNDERCUT TOILET ROOM DOOR 3/4" MINIMUM TO FACILITATE AIR FLOW (TYPICAL OF 2). COORDINATE WITH GENERAL CONTRACTOR. • 6" MINIMUM CLEAR OPEN HEIGHT ABOVE COMMON TENANT DEMISING WALL AND BELOW STRUCTURE, OR OTHER BUILDING ELEMENTS (DUCTS, ETC.) THAT WILL ALLOW THE PASSAGE OF RETURN AIR BACK TO THE LANDLORD UNIT. 10 PROVIDE AND INSTALL VOLUME DAMPER AT DIFFUSER CONNECTION TO BRANCH DUCT (TYPICAL). 11 LANDLORD'S EXISTING SUPPLY AIR DUCT TO MALL. FIELD VERIFY EXACT SIZE AND LOCATION. AVOID WITH ALL NEW CONSTRUCTION. EXISTING DRAIN PIPE TO REMAIN. FIELD VERIFY EXACT SIZE AND LOCATION. EXISTING 8" DUCT TO REMAIN. FIELD VERIFY IF DUCT IS AN EXHAUST MAIN FOR TOILET EXHAUST DUCT TO CONNECT TO. FIELD VERIFY EXACT SIZE, LOCATION, AND USE OF DUCT. 16 LANDLORD'S EXISTING SUPPLY MAIN DUCT TAP (TYPICAL OF 2). FIELD VERIFY EXACT SIZE AND LOCATION. 17 LANDLORD'S EXISTING SUPPLY AIR MAIN. FIELD VERIFY EXACT SIZE AND LOCATION. 18 MEDIUM PRESSURE 12 "0 SUPPLY AIR DUCT TO VAV BOX SUPPLIED AND INSTALLED BY HVAC CONTRACTOR (TYPICAL OF 2). COORDINATE CONNECTION REQUIREMENTS TO LANDLORD'S SUPPLY AIR MAIN DUCT WITH LANDLORD. 400 SUPPLY AND INSTALL SPRINKLER HEAD ON FITTING ROOM CEILING (TYPICAL OF 4). COORDINATE EXACT LOCATION WITH CEIUNG GRID AND LIGHT FIXTURES. MODIFY PIPING AS REQUIRED. MALL'S EXISTING SUPPLY AIR MAIN TO REMAIN. FIELD VERIFY EXACT LOCATION AND SIZE. NEW TRANE MODEL FAN POWERED VAV BOX WITH ELECTRIC HEAT SUPPLIED BY TENANT AND INSTALLED BY HVAC CONTRACTOR (TYPICAL OF 2). CONNECT TO LANDLORD'S EXISTING SUPPLY AIR DUCT. REFER TO SCHEDULE FOR ADDITIONAL INFORMATION AND CFM. EXISTING MALL PIPING TO REMAIN. FIELD VERIFY EXACT SIZE AND LOCATION. AVOID WITH ALL NEW CONSTRUCTION. 21 PROVIDE AND INSTALL TURNING VANES AT ALL SQUARE /RECTANGULAR DUCT ELBOWS (TYPICAL). • FLEXIBLE DUCT, MAXIMUM LENGTH 5' -0 ". PROVIDE SMOOTH TRANSITIONS AND PROPER SUPPORTS PER S.M.A.C.N.A. (TYPICAL). USE FLEXIBLE DUCT FOR FINAL RUNOUT TO DIFFUSERS ONLY. REFER TO SCHEDULE FOR FLEXIBLE DUCT SIZES. ©3 PROVIDE AND INSTALL ACCESS PANEL FOR MAINTENANCE OF VAV BOX (TYPICAL OF 2). COORDINATE WITH GENERAL CONTRACTOR FOR EXACT LOCATION AND SIZE. ® FIELD VERIFY AND COORDINATE WITH LANDLORD TO SEE IF THIS WALL IS REQUIRED TO HAVE 6" MIN. CLEARANCE BETWEEN STRUCTURE AND TOP OF DEMISING WALL. MALL COMMON AREA IS ADJACENT TO TENANT SPACE. COORDINATE WITH WET SEAL'S GENERAL CONTRACTOR AFTER VERIFICATION. NOTE: CONTRACTOR TO PROVIDE ALL ELECTRONIC CONTROLS AS REQUIRED. COORDINATE WITH LANDLORD ON EXACT TYPE REQUIRED. w 0 8" OT.E. giiii ' 0 7 10 "0 NECK (TYP. OF 7) 0 • 14 "x 14 "S.A. iSPJ PER 2006 IMC SECTION 606 Install smoke detector to shut down air distribution by VAV's when the total combined C F M of all VAV's (to include other tenants) sharing the same plenum space exceeds 2000 CFM. (See IMC 606.2.2 for approved method of detection /7. .X77 WifiEacgiffa7eq"/*:-VA 0 0 MECHANICAL PLAN SCALE Vr • ro VAV-2 CONTRACTORS REQUIRED BY LANDLORD THE FOLLOWING LANDLORD REQUIRED CONTRACTORS SHALL BE EMPLOYED AT TENANT G.C.'S EXPENSE FIRE ALARM CONTRACTOR: GUARDIAN SECURITY 9435 PROVOST ROAD NW SILVERDALE, WASHINGTON 98383 PHONE: 360 -692 -3738 FAX: 360 -692 -6857 E —MAIL: BOB VEZZANI bvezzani ®guardiansecurity.com ADMIN: PONY MAURICE pmaurica®guardiansecurity.com SPRINKLER CONTRACTORS: PATRIOT FIRE PROTECTION, INC. ATTN: MARK FROMONG 2707 70TH AVENUE EAST TACOMA, WASHINGTON 98424 PHONE: 253 - 926 -2290 253 -284 -3535 FAX: 253-922-6150 E —MAIL: markf @patriotfire.com CROWN FIRE PROTECTION, INC. ATTN: JOHN ABEL 4932 WEST INTERURBAN BLVD. BOTHELL., WASHINGTON 98012 PHONE: 425 -481 -7669 FAX: 425-481-8695 E — MAIL: jabel©crownfp.com COSCO FIRE PROTECTION ATTN: PATRICK CARNAHAN 15000 WOODINVILLE — REDMOND RD. SUITE #B -800 WOODINVILLE, WASHINGTON 98072 PHONE: 425-827-9654 425 -686 -6313 FAX: 425 - 827 -4784 E — MAIL: pcarnahan ®coscofire.com WESTERN STATES FIRE PROTECTION CO. ATTN: WES HAMILTON 7102 180TH AVENUE NE, #A-105 REDMOND, WASHINGTON 98052 PHONE: 425 - 881 -0100 FAX: 425-881-3030 E —MAIL: weston.hamilton@wsfp.com MECHANICAL CONTRACTOR'S NOTES= ALL OF THE MECHANICAL & SPRINKLER WORK IS NOT NECESSARILY SHOWN OR NOTED ON THESE DRAWINGS. THE CONTRACTORS SHALL VISIT THE JOB SITE AND VERIFY ALL EXISTING CONDITIONS RELATED TO THE WORK PRIOR TO BIDDING. THOSE ITEMS NOT SHOWN OR NOTED, BUT ARE DEEMED NECESSARY FOR REMOVAL OR RELOCATION BY THE OWNER OR HIS REPRESENTATIVE, SHALL BE PART OF THIS CONTRACT. THE SUBMISSION OF THE PROPOSALS SHALL BE CONSIDERED AS EVIDENCE THAT THE CONTRACTORS HAVE VISITED THE SITE. NO EXTRA PAYMENTS WILL BE ALLOWED, DUE TO EXTRA WORK MADE NECESSARY BY THE CONTRACTOR'S FAILURE TO VISIT THE JOB SITE. Off i\4 MO SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical 4 Electrical [Plumbing nir Gas Piping { City of TukW a i BUII.Du -4 Dpi V: IC,N 1 REVISIONS No changes shall be made to th.. scopa of work without prior approval of Tukwila Building Division NOTE: Revisions will require a new plan submittal and may include additional plan review fees FILE COPY Permit No ar review approval is subject to errors and omissins .. proval of construction documents does not sho e violation of any =dopted code or °Wham. Rae �. = Linilt {sY L. ti is owlcd ed: Date: 041 C" = of Tukwila BUILDING DIVISION i RED FOR CODE COMPLIANCE APPROVED tiPR 1 A 2008 ATA RECEIVED MAR 2 7 2008 PERMIT CENTEF 3 J i ,WWWW, CO icnf M100 HVAC SYMBOLS LEGEND 7 RETURN AIR GRILLE SUPPLY AIR DIFFUSER RETURN AIR SUPPLY AIR R.A.G. DIFF. M.D. F.D. F.C. RETURN AIR GRILLE DIFFUSER MANUAL DAMPER FIRE DAMPER FLEXIBLE CONNECTION AIR DEVICE TYPE ■ � AIR VOLUME IN CUBIC FEET /MINUTE (CFM) THERMOSTAT R.A. S.A. OT LANDLORD NOTES DO NOT ATTACH ANYTHING DIRECTLY TO SLAB OR ROOF DECK ABOVE. TENANT SHALL MAINTAIN A MINIMUM OF 6" UNOBSTRUCTED CLEARANCE HEIGHT IN RETURN AIR PLENUM ABOVE CEIUNG ALLOWING FOR AIR FLOW BACK TO LANDLORD'S AIR CONDITIONING UNIT. LANDLORD PROVIDED A TENANT FIRE SERVICE MAIN WITH BRANCH PIPING STUBBED INTO EACH TENANT'S SPACE. LANDLORD'S SPRINKLER SYSTEM I5 DESIGNED PER ORDINARY HAZARD GROUP 2 AND THE LATEST REQUIREMENTS OF NFPA -13. NO ISOLATION VALVES WILL BE PROVIDED OR PERMITTED. TENANT SHALL CONNECT A FIRE SPRINKLER SYSTEM TO LANDLORD'S SPRINKLER SYSTEM WITHIN THE DEMISED PREMISES USING APPROVED MECHANICAL FITTINGS. TENANT SHALL PROVIDE AND INSTALL ALL BRANCH PIPING AND SPRINKLERS REQUIRED TO COMPLETE THE SPRINKLER SYSTEM WITHIN THE TENANT SPACE. TENANT'S SPRINKLER SYSTEM DESIGNS SHALL BE BASED UPON THE REQUIREMENTS OF THE STATE OF WASHINGTON, CITY OF TUKWILA FIRE DEPT. TENANT SHALL ENGAGE THE SERVICES OF A LANDLORD PREFERRED FIRE SPRINKLER CONTRACTOR TO DESIGN, PERMIT, AND INSTALL TENANT'S FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH THE BASE BUILDING DESIGN SPECIFICATIONS. SPRINKLER LAYOUT AND AND PIPE SIZING SHALL BE HYDRAULICALLY DESIGNED ACCORDING TO ORDINARY HAZARD GROUP 2 AND THE LATEST REQUIREMENTS OF NFPA -13. ALL SPRINKLER HEADS IN THE FORWARD SELLING AREA ARE TO BE CONCEALED POP OFF COVER TYPE. ALL SUPPORTS SHALL BE FROM STRUCTURAL BEAMS AND JOISTS, NOT FROM FLOOR OR ROOF DECK ABOVE. TENANT'S CONTRACTOR SHALL INSTALL AN INSPECTORS TEST CONNECTION, PIPED TO A FUNNEL DRAIN, (WITH WET TRAP), MOUNTED 3' -0" A.F.F.. INSTALL A 1" CORROSION RESISTANT SHUT—OFF VALVE. TENANT SHALL INSTALL A VANE TYPE WATERFLOW DETECTOR IN THE MAIN SPRINKLER LINE IMMEDIATELY AFTER CONNECTION TO THE LANDLORD'S MAIN, WHICH IS CONNECTED TO THE LANDLORD'S FIRE ALARM SYSTEM. * OR APPROVED EQUAL O HVAC -I- SPRINKLER KEYED NOTES 0 O NEW VAV COMPATIBLE THERMOSTAT SUPPLIED AND INSTALLED BY HVAC CONTRACTOR. (TYPICAL OF 2). COORDINATE WITH ELECTRICAL CONTRACTOR. MOUNTING HEIGHT 4' —O" A.F.F. PROVIDE LOCKING LUCITE COVER. TURN KEY OVER TO STORE MANAGER. ® COMBINATION EXHAUST FAN /LIGHT SUPPLIED & INSTALLED BY HVAC CONTRACTOR (TYPICAL OF 2). TEIBER MODEL #TFL9OL, 4 "0 DUCT SIZE, 165 W, 90 CFM, 2.0 SONES, 120v/1 ph /60hz. PROVIDE BACKDRAFT DAMPER. EXTEND AND CONNECT TO LANDLORD'S TOILET EXHAUST DUCT STUB —IN. FIELD VERIFY EXACT SIZE AND LOCATION. IF NO EXISTING LANDLORD EXHAUST DUCT, PROVIDE NEW TOILET EXHAUST DUCT THRU ROOF AS REQUIRED. MAINTAIN 10' -0" MIN. AWAY FROM ANY OUTSIDE AIR INTAKES. VERIFY IN FIELD. ® PROVIDE & INSTALL NEW SPRINKLER HEAD ON TOILET ROOM CEILING (TYPICAL OF 2). COORDINATE EXACT LOCATION WITH LIGHT /FAN FIXTURE. MODIFY SUPPLY PIPING AS REQUIRED. O PROVIDE NEW OR RELOCATE EXISTING SPRINKLER HEAD AS REQUIRED TO ACCOMMODATE NEW GYP. BD. CEILING (TYP.). COORDINATE EXACT LOCATION WITH NEW CEIUNG FIXTURES AND LIGHTS. MODIFY SUPPLY PIPING AS REQUIRED. ® NEW 2A -20B:C FIRE EXTINGUISHER PROVIDED AND INSTALLED BY GENERAL CONTRACTOR. COORDINATE EXACT QUANTITY AND LOCATION(S) WITH LANDLORD AND LOCAL FIRE MARSHALL. L/ APPROXIMATE LOCATION OF EXISTING SPRINKLER SYSTEM MAIN. FIELD VERIFY EXACT SIZE AND LOCATION. O NEW 2.5" THICK (R -7) EXTERNALLY INSULATED LOW PRESSURE SUPPLY AIR DUCT SUPPLIED AND INSTALLED BY HVAC CONTRACTOR (TYPICAL OF 2 HVAC SYSTEMS). PROVIDE TRANSITIONS AS REQUIRED, DUCT DIMENSIONS ARE CLEAR INTERNAL AIR PATH DIMENSIONS. HOLD ALL DUCTWORK AS HIGH AS POSSIBLE AND /OR PRACTICAL IN JOIST SPACE. ® CONTRACTOR TO ENSURE DOOR IS UNDERCUT TOILET ROOM DOOR 3/4" MINIMUM TO FACILITATE AIR FLOW (TYPICAL OF 2). COORDINATE WITH GENERAL CONTRACTOR. • 6" MINIMUM CLEAR OPEN HEIGHT ABOVE COMMON TENANT DEMISING WALL AND BELOW STRUCTURE, OR OTHER BUILDING ELEMENTS (DUCTS, ETC.) THAT WILL ALLOW THE PASSAGE OF RETURN AIR BACK TO THE LANDLORD UNIT. 10 PROVIDE AND INSTALL VOLUME DAMPER AT DIFFUSER CONNECTION TO BRANCH DUCT (TYPICAL). 11 LANDLORD'S EXISTING SUPPLY AIR DUCT TO MALL. FIELD VERIFY EXACT SIZE AND LOCATION. AVOID WITH ALL NEW CONSTRUCTION. EXISTING DRAIN PIPE TO REMAIN. FIELD VERIFY EXACT SIZE AND LOCATION. EXISTING 8" DUCT TO REMAIN. FIELD VERIFY IF DUCT IS AN EXHAUST MAIN FOR TOILET EXHAUST DUCT TO CONNECT TO. FIELD VERIFY EXACT SIZE, LOCATION, AND USE OF DUCT. 16 LANDLORD'S EXISTING SUPPLY MAIN DUCT TAP (TYPICAL OF 2). FIELD VERIFY EXACT SIZE AND LOCATION. 17 LANDLORD'S EXISTING SUPPLY AIR MAIN. FIELD VERIFY EXACT SIZE AND LOCATION. 18 MEDIUM PRESSURE 12 "0 SUPPLY AIR DUCT TO VAV BOX SUPPLIED AND INSTALLED BY HVAC CONTRACTOR (TYPICAL OF 2). COORDINATE CONNECTION REQUIREMENTS TO LANDLORD'S SUPPLY AIR MAIN DUCT WITH LANDLORD. 400 SUPPLY AND INSTALL SPRINKLER HEAD ON FITTING ROOM CEILING (TYPICAL OF 4). COORDINATE EXACT LOCATION WITH CEIUNG GRID AND LIGHT FIXTURES. MODIFY PIPING AS REQUIRED. MALL'S EXISTING SUPPLY AIR MAIN TO REMAIN. FIELD VERIFY EXACT LOCATION AND SIZE. NEW TRANE MODEL FAN POWERED VAV BOX WITH ELECTRIC HEAT SUPPLIED BY TENANT AND INSTALLED BY HVAC CONTRACTOR (TYPICAL OF 2). CONNECT TO LANDLORD'S EXISTING SUPPLY AIR DUCT. REFER TO SCHEDULE FOR ADDITIONAL INFORMATION AND CFM. EXISTING MALL PIPING TO REMAIN. FIELD VERIFY EXACT SIZE AND LOCATION. AVOID WITH ALL NEW CONSTRUCTION. 21 PROVIDE AND INSTALL TURNING VANES AT ALL SQUARE /RECTANGULAR DUCT ELBOWS (TYPICAL). • FLEXIBLE DUCT, MAXIMUM LENGTH 5' -0 ". PROVIDE SMOOTH TRANSITIONS AND PROPER SUPPORTS PER S.M.A.C.N.A. (TYPICAL). USE FLEXIBLE DUCT FOR FINAL RUNOUT TO DIFFUSERS ONLY. REFER TO SCHEDULE FOR FLEXIBLE DUCT SIZES. ©3 PROVIDE AND INSTALL ACCESS PANEL FOR MAINTENANCE OF VAV BOX (TYPICAL OF 2). COORDINATE WITH GENERAL CONTRACTOR FOR EXACT LOCATION AND SIZE. ® FIELD VERIFY AND COORDINATE WITH LANDLORD TO SEE IF THIS WALL IS REQUIRED TO HAVE 6" MIN. CLEARANCE BETWEEN STRUCTURE AND TOP OF DEMISING WALL. MALL COMMON AREA IS ADJACENT TO TENANT SPACE. COORDINATE WITH WET SEAL'S GENERAL CONTRACTOR AFTER VERIFICATION. NOTE: CONTRACTOR TO PROVIDE ALL ELECTRONIC CONTROLS AS REQUIRED. COORDINATE WITH LANDLORD ON EXACT TYPE REQUIRED. w 0 8" OT.E. giiii ' 0 7 10 "0 NECK (TYP. OF 7) 0 • 14 "x 14 "S.A. iSPJ PER 2006 IMC SECTION 606 Install smoke detector to shut down air distribution by VAV's when the total combined C F M of all VAV's (to include other tenants) sharing the same plenum space exceeds 2000 CFM. (See IMC 606.2.2 for approved method of detection /7. .X77 WifiEacgiffa7eq"/*:-VA 0 0 MECHANICAL PLAN SCALE Vr • ro VAV-2 CONTRACTORS REQUIRED BY LANDLORD THE FOLLOWING LANDLORD REQUIRED CONTRACTORS SHALL BE EMPLOYED AT TENANT G.C.'S EXPENSE FIRE ALARM CONTRACTOR: GUARDIAN SECURITY 9435 PROVOST ROAD NW SILVERDALE, WASHINGTON 98383 PHONE: 360 -692 -3738 FAX: 360 -692 -6857 E —MAIL: BOB VEZZANI bvezzani ®guardiansecurity.com ADMIN: PONY MAURICE pmaurica®guardiansecurity.com SPRINKLER CONTRACTORS: PATRIOT FIRE PROTECTION, INC. ATTN: MARK FROMONG 2707 70TH AVENUE EAST TACOMA, WASHINGTON 98424 PHONE: 253 - 926 -2290 253 -284 -3535 FAX: 253-922-6150 E —MAIL: markf @patriotfire.com CROWN FIRE PROTECTION, INC. ATTN: JOHN ABEL 4932 WEST INTERURBAN BLVD. BOTHELL., WASHINGTON 98012 PHONE: 425 -481 -7669 FAX: 425-481-8695 E — MAIL: jabel©crownfp.com COSCO FIRE PROTECTION ATTN: PATRICK CARNAHAN 15000 WOODINVILLE — REDMOND RD. SUITE #B -800 WOODINVILLE, WASHINGTON 98072 PHONE: 425-827-9654 425 -686 -6313 FAX: 425 - 827 -4784 E — MAIL: pcarnahan ®coscofire.com WESTERN STATES FIRE PROTECTION CO. ATTN: WES HAMILTON 7102 180TH AVENUE NE, #A-105 REDMOND, WASHINGTON 98052 PHONE: 425 - 881 -0100 FAX: 425-881-3030 E —MAIL: weston.hamilton@wsfp.com MECHANICAL CONTRACTOR'S NOTES= ALL OF THE MECHANICAL & SPRINKLER WORK IS NOT NECESSARILY SHOWN OR NOTED ON THESE DRAWINGS. THE CONTRACTORS SHALL VISIT THE JOB SITE AND VERIFY ALL EXISTING CONDITIONS RELATED TO THE WORK PRIOR TO BIDDING. THOSE ITEMS NOT SHOWN OR NOTED, BUT ARE DEEMED NECESSARY FOR REMOVAL OR RELOCATION BY THE OWNER OR HIS REPRESENTATIVE, SHALL BE PART OF THIS CONTRACT. THE SUBMISSION OF THE PROPOSALS SHALL BE CONSIDERED AS EVIDENCE THAT THE CONTRACTORS HAVE VISITED THE SITE. NO EXTRA PAYMENTS WILL BE ALLOWED, DUE TO EXTRA WORK MADE NECESSARY BY THE CONTRACTOR'S FAILURE TO VISIT THE JOB SITE. Off i\4 MO SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical 4 Electrical [Plumbing nir Gas Piping { City of TukW a i BUII.Du -4 Dpi V: IC,N 1 REVISIONS No changes shall be made to th.. scopa of work without prior approval of Tukwila Building Division NOTE: Revisions will require a new plan submittal and may include additional plan review fees FILE COPY Permit No ar review approval is subject to errors and omissins .. proval of construction documents does not sho e violation of any =dopted code or °Wham. Rae �. = Linilt {sY L. ti is owlcd ed: Date: 041 C" = of Tukwila BUILDING DIVISION i RED FOR CODE COMPLIANCE APPROVED tiPR 1 A 2008 ATA RECEIVED MAR 2 7 2008 PERMIT CENTEF 3 J i ,WWWW, CO icnf M100 VAV BOX SCHEDULE 0/As/-1 —I— VAV -2) MANUFACTURER 19501 CRAIG 0 , ` 0 J S. L [S, itA0 314 J !314 ) 415i24O 0 FAX (314) 115 -2000 L wwwarci.corn Iss 1 1 . T ---"1 711 -".7: 1 1 MINIMUM AIR CFM TOTAL CFM INLET SIZE TRANE VPEF1200Q (PARALLEL FAN POWERED) 545 1,890 12" DISCHARGE SIZE ELEC. HEAT BASE UNIT WEIGHT FAN SIZE FAN HP FLA 20 "x16" 4.0 KW © 460 V, 3 PH 96 LBS 03SQ 1/3 () 277V, 1 PH 1.6 ..... , k ._...n... -I :31va 38551 :_ .:.:::_.:.- w:.:_:_.:: -, - „_ _ ...... ' .. 1S !AO 03AO3H3 1,2,3,5,6 TDCA-- 3/AG -95 24 "x24" 10 "0 10 "0 DIFF. 1,2,4 I M100 1 VAV BOX SCHEDULE 0/As/-1 —I— VAV -2) MANUFACTURER MODEL NO. MINIMUM AIR CFM TOTAL CFM INLET SIZE TRANE VPEF1200Q (PARALLEL FAN POWERED) 545 1,890 12" DISCHARGE SIZE ELEC. HEAT BASE UNIT WEIGHT FAN SIZE FAN HP FLA 20 "x16" 4.0 KW © 460 V, 3 PH 96 LBS 03SQ 1/3 () 277V, 1 PH 1.6 AIR DEVICE SCHEDULE Q HVAC SYMBOLS LEGEND QTY • v1 RETURN AIR GRILLE SUPPLY AIR DIFFUSER RETURN AIR SUPPLY AIR NECK SIZE FLEX SIZE CFM ( ) R.A.G. DIFF. M.D. F.D. F.C. RETURN AIR GRILLE DIFFUSER MANUAL DAMPER FIRE DAMPER FLEXIBLE CONNECTION TDCA- 3/AG --95 AIR DEVICE TYPE 10 "0 10 "0 DIFF. AIR VOLUME IN CUBIC FEET MINUTE / THERMOSTAT R.A. S.A. Q AIR DEVICE SCHEDULE Q PLAN MARK QTY • *TITUS MODEL NO. FACE SIZE NECK SIZE FLEX SIZE TYPE NOTES TDCA- 3/AG --95 24 "x24" 10 "0 10 "0 DIFF. 1,2,3,5,6 TDCA-3/AG-95 24 "x24" 12 "0 12 "0 DIFF. 1,2,3,5,6 TDCA-- 3/AG -95 24 "x24" 10 "0 10 "0 DIFF. 1,2,4 TDCA- 3/AG -95 24 "x24" 8 "o 8 "0 DIFF. 1,2,4 50 F 24 "x24" 22 "x22" N/A R.A.G. 4 50 F 24 "x24" 22"x22" N/A R.A.C. 3,5,6 PLAN FOR THROW PATTERN 1. REFER TO 2. PROVIDE AND INSTALL MANUAL VOLUME DAMPER 3. FRAME -IALL AT GYP. BD. ROUGH —IN OPENING \........ -' 4. FRAME -IALL FIT LAY —N CEILING MODULE 5. TOR SHALL COORDINATE REQUIRED ACCESSORIES AND INSTALLATION WITH LOCAL "TITUS" REP. PRIOR TO ORDERING AND INSTALLATION OF AIR DISTRIBUTION 6. TRM ME (TO BE UTILIZED AS ACCESS PANEL ABOVE CEILING WHEN REQ'D.) LANDLORD NOTES DO NOT ATTACH ANYTHING DIRECTLY TO SLAB OR ROOF DECK ABOVE. TENANT TALL MAINTAIN A MINIMUM OF 6" UNOBSTRUCTED CLEARANCE HEIGHT IN RETURN AIR M ABOVE CEIUNG ALLOWING FOR AIR FLOW BACK TO LANDLORD'S AIR CONDITIONING UNIT. ORD PROVIDED A TENANT FIRE SERVICE MAIN WITH BRANCH PIPING STUBBED INTO EACH TENANT'S SPACE. LANDLORD'S SPRINKLER SYSTEM I5 DESIGNED PER ORDINARY HAZARD GROUP 2 AND THE LATEST REQUIREMENTS OF NFPA -13. NO ISOLATION VALVES WILL BE PROVIDED OR PERMITTED. TENANT TALL CONNECT A FIRE SPRINKLER SYSTEM TO LANDLORD'S SPRINKLER SYSTEM WITHIN THE DEMISED PREMISES USING APPROVED MECHANICAL FITTINGS. TENANT SHALL PROVIDE ND INSTALL ALL BRANCH PIPING AND SPRINKLERS REQUIRED TO COMPLETE THE SPRINKLER SYSTEM WITHIN THE TENANT SPACE. TENANT'S SPRINKLER SYSTEM DESIGNS SHALL BE BASED UPON THE REQUIREMENTS OF THE STATE OF WASHINGTON, CITY OF TUKWILA IRE DEPT. TENANT SHALL ENGAGE THE SERVICES OF A LANDLORD PREFERRED FIRE SPRINKLER CONTRACTOR TO DESIGN, PERMIT, AND INSTALL TENANT'S FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH THE BASE BUILDING DESIGN SPECIFICATIONS. SPRINKLER LAYOUT D AND PIPE SIZING SHALL BE HYDRAULICALLY DESIGNED ACCORDING TO ORDINARY HAZARD GROUP 2 AND THE LATEST REQUIREMENTS OF ,NFPA -13. ALL SPRINKLER HEADS IN THE FORWARD SELLING AREA ARE TO BE CONCEALED POP OFF COVER E. ALL SUPPORTS SHALL BE FROM STRUCTURAL BEAMS AND JOISTS, NOT FROM FLOOR OR ROOF < ABOVE. CONTRACTOR SHALL INSTALL AN INSPECTORS TEST CONNECTION, PIPED TO A FUNNEL LAIN, (WITH WET TRAP), MOUNTED 3' -0" A.F.F.. INSTALL A 1" CORROSION RESISTANT SHUT —OFF VALVE. TENANT TALL INSTALL A VANE TYPE WATERFLOW DETECTOR IN THE MAIN SPRINKLER LINE IMMEDIATELY AFTER CONNECTION TO THE LANDLORD'S MAIN, WHICH IS CONNECTED TO THE LANDLORD'S FIRE ALARM SYSTEM. GENERAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL WITHIN THE LANDLORD'S TENANT CRITERIA MANUAL INCLUDING ITS RULES AND REGULATIONS. CONTRACTOR IS TO VERIFY LOCATION; GET APPROVAL AND REQUIREMENTS FOR ALL HING WITH WESTFIELD'S ON —SITE TENANT COORDINATORS BEFORE PROCEEDING WITH WORK. TENANT TALL PROPERLY SEAL ALL PENENTRATIONS TO COMPLY WITH CODE REQUIREMENTS. THE FIRE RATED FLOOR ASSEMBLY SHALL BE MAINTAINED. ALL MECHANICAL AND ELECTRICAL DEVICES PENETRATING FLOOR SHALL BE FIRE CONTRACTOR SHALL PROVIDE A FIRE WATCH AND PORTABLE EXTINGUISHER WHERE EVERY ANY WELDING IS DONE WITHIN THE DEMISED PREMISES. THE PERSON PERFORMING THE FIRE WATCH SHALL REMAIN IN THE TENANT SPACE FOR AT LEAST 1 HOUR :R THE COMPLETION OF ANY WELDING. THIS SHALL BE COORDINATED THROUG THE CITY OF TUKWILA FIRE DEPARTMENT. APPROVED EQUAL 0 0 Q HVAC + SPRINKLER KEYED NOTES 0 ® NEW VAV COMPATIBLE THERMOSTAT SUPPLIED AND INSTALLED BY HVAC CONTRACTOR. (TYPICAL OF 2). COORDINATE WITH ELECTRICAL CONTRACTOR. MOUNTING HEIGHT 4' —O" A.F.F. PROVIDE LOCKING LUCITE COVER. TURN KEY OVER TO STORE MANAGER. Q2 COMBINATION EXHAUST FAN /LIGHT SUPPLIED & INSTALLED BY HVAC CONTRACTOR (TYPICAL OF 2). TEIBER MODEL #TFL9OL, 4'"0 DUCT SIZE, 165 W, 90 CFM, 2.0 SONES, 120v/1 ph /60hz. PROVIDE BACKDRAFT DAMPER. EXTEND AND CONNECT TO LANDLORD'S TOILET EXHAUST DUCT STUB —IN. FIELD VERIFY EXACT SIZE AND LOCATION. IF NO EXISTING LANDLORD EXHAUST DUCT, PROVIDE NEW TOILET EXHAUST DUCT THRU ROOF AS REQUIRED. MAINTAIN 10' -0" MIN. AWAY FROM ANY OUTSIDE AIR INTAKES. VERIFY IN FIELD. Q3 PROVIDE & INSTALL NEW SPRINKLER HEAD ON TOILET ROOM CEILING (TYPICAL OF 2). COORDINATE EXACT LOCATION WITH LIGHT /FAN FIXTURE. MODIFY SUPPLY PIPING AS REQUIRED. ® PROVIDE NEW OR RELOCATE EXISTING SPRINKLER HEAD AS REQUIRED TO ACCOMMODATE NEW GYP. BD. CEILING (TYP.). COORDINATE EXACT LOCATION WITH NEW CEILING FIXTURES AND LIGHTS. MODIFY SUPPLY PIPING AS REQUIRED. V NEW 2A -20B:C FIRE EXTINGUISHER PROVIDED AND INSTALLED BY GENERAL CONTRACTOR. COORDINATE EXACT QUANTITY AND LOCATION(S) WITH LANDLORD AND LOCAL FIRE MARSHALL • APPROXIMATE LOCATION OF EXISTING SPRINKLER SYSTEM MAIN. FIELD VERIFY EXACT SIZE AND LOCATION. 0 NEW 2.5" THICK (R -7) EXTERNALLY INSULATED LOW PRESSURE SUPPLY AIR DUCT SUPPLIED AND INSTALLED BY HVAC CONTRACTOR (TYPICAL OF 2 HVAC SYSTEMS). PROVIDE TRANSITIONS AS REQUIRED, DUCT DIMENSIONS ARE CLEAR INTERNAL AIR PATH DIMENSIONS. HOLD ALL DUCTWORK AS HIGH AS POSSIBLE AND /OR PRACTICAL IN JOIST SPACE. ® CONTRACTOR TO ENSURE DOOR IS UNDERCUT TOILET ROOM DOOR 3/4" MINIMUM TO FACILITATE AIR FLOW (TYPICAL OF 2). COORDINATE WITH GENERAL CONTRACTOR. ® 6" MINIMUM CLEAR OPEN HEIGHT ABOVE COMMON TENANT DEMISING WALL AND BELOW STRUCTURE, OR OTHER BUILDING ELEMENTS (DUCTS, ETC.) THAT WILL ALLOW THE PASSAGE OF RETURN AIR BACK TO THE LANDLORD UNIT. 10 PROVIDE AND INSTALL VOLUME DAMPER AT DIFFUSER CONNECTION TO BRANCH DUCT (TYPICAL). 11 LANDLORD'S EXISTING SUPPLY AIR DUCT TO MALL. FIELD VERIFY EXACT SIZE AND LOCATION. AVOID WITH ALL NEW CONSTRUCTION. 12 MALL'S EXISTING SUPPLY AIR MAIN TO REMAIN. FIELD VERIFY EXACT LOCATION AND SIZE. 13 NEW TRANE MODEL FAN POWERED VAV BOX WITH ELECTRIC HEAT SUPPLIED BY TENANT AND INSTALLED BY HVAC CONTRACTOR (TYPICAL OF 2). CONNECT TO LANDLORD'S EXISTING SUPPLY AIR DUCT. REFER TO SCHEDULE FOR ADDITIONAL INFORMATION AND CFM. 14 EXISTING DRAIN PIPE TO REMAIN. FIELD VERIFY EXACT SIZE AND LOCATION. 15 EXISTING 8 DUCT TO REMAIN. FIELD VERIFY IF DUCT IS AN EXHAUST MAIN FOR TOILET EXHAUST DUCT TO CONNECT TO. FIELD VERIFY EXACT SIZE, LOCATION, AND USE OF DUCT. O. LANDLORD'S EXISTING SUPPLY MAIN DUCT TAP (TYPICAL OF 2). FIELD VERIFY EXACT SIZE AND LOCATION. 17 LANDLORD'S EXISTING SUPPLY AIR MAIN. FIELD VERIFY EXACT SIZE AND LOCATION. 18 MEDIUM PRESSURE 12 "0 SUPPLY AIR DUCT TO VAV BOX SUPPLIED AND INSTALLED BY HVAC CONTRACTOR (TYPICAL OF 2). COORDINATE CONNECTION REQUIREMENTS TO LANDLORD'S SUPPLY AIR MAIN DUCT WITH LANDLORD. 19 SUPPLY AND INSTALL SPRINKLER HEAD ON FITTING ROOM CEILING (TYPICAL OF 4). COORDINATE EXACT LOCATION WITH CEIUNG GRID AND LIGHT FIXTURES. MODIFY PIPING AS REQUIRED. 2Q0 EXISTING MALL PIPING TO REMAIN. FIELD VERIFY EXACT SIZE AND LOCATION. AVOID WITH ALL NEW CONSTRUCTION. 21 PROVIDE AND INSTALL TURNING VANES AT ALL SQUARE /RECTANGULAR DUCT ELBOWS (TYPICAL). • FLEXIBLE DUCT, MAXIMUM LENGTH 5' -0 ". PROVIDE SMOOTH TRANSITIONS AND PROPER SUPPORTS PER S.M.A.C.NA. (TYPICAL). USE FLEXIBLE DUCT FOR FINAL RUNOUT TO DIFFUSERS ONLY. REFER TO SCHEDULE FOR FLEXIBLE DUCT SIZES. Co PROVIDE AND INSTALL ACCESS PANEL FOR MAINTENANCE OF VAV BOX (TYPICAL OF 2). COORDINATE WITH GENERAL CONTRACTOR FOR EXACT LOCATION AND SIZE. FIELD VERIFY AND COORDINATE WITH LANDLORD TO SEE IF THIS WALL IS REQUIRED TO HAVE 6" MIN. CLEARANCE BETWEEN STRUCTURE AND TOP OF DEMISING WALL. MALL COMMON AREA IS ADJACENT TO TENANT SPACE. COORDINATE WITH WET SEAL'S GENERAL CONTRACTOR AFTER VERIFICATION. • HVAC CONTRACTOR SHALL SUPPLY AND INSTALL A RETURN PLENUM ON VAV BOX WITH A SMOKE DETECTOR ON VAV RETURN (PLENUM INTAKE) WITH INTEGRATED SHUTDOWN FEATURE (TYPICAL OF 2). COORDINATE EXACT TYPE AND LOCATION WITH LANDLORD'S OPERATIONS MANAGER. NOTE: CONTRACTOR TO PROVIDE ALL ELECTRONIC CONTROLS AS REQUIRED. COORDINATE WITH LANDLORD ON EXACT TYPE REQUIRED. 1 6 "OT.E. 0 \ SP; 7v 0 1 VAV— 1 10 "0 NECK (TYP. OF 7) COMMISSIONNG REFER TO NREC SECTION 1416 AND THE BUILDING COMMISSIONING GUIDELINES, PUBLISHED BY THE BUILDING COMMISSIONING ASSOCIATION, FOR COMPLETE TEXT AND GUILDELINES FOR BUILDING COMPLETION AND COMMISSIONING REQUIREMENTS. , . ,i. a, ,1/ . Zg./.<.4. .17/2 `•,' F /.,?;F.f.I.G,Fi %fif .f. /< t�fd 7 .� 14 "x 14 "S.A. 0 A 420 MECHANICAL PLAN SCALE 1/4' 1-0 VAV -2 �Zig all 4 • v. r• CONTRACTORS REQUIRED BY LANDLORD THE FOLLOWING LANDLORD REQUIRED CONTRACTORS SHALL BE EMPLOYED AT TENANT G.C.'S EXPENSE FIRE ALARM CONTRACTOR: GUARDIAN SECURITY 9435 PROVOST ROAD NW SILVERDALE, WASHINGTON 98383 PHONE: 360 -692 -3738 FAX: 360 -692 -6857 E—MAIL: BOB VEZZANI bvezzani@guardiansecurity.com ADMIN: PONY MAURICE pmaurica©guardiansecurity.com SPRINKLER CONTRACTORS: PATRIOT FIRE PROTECTION, INC. ATTN: MARK FROMONG 2707 70TH AVENUE EAST TACOMA, WASHINGTON 98424 PHONE: 253-926-2290 253- 284 -3535 FAX: 253 -922 -6150 E —MAIL: markf@patriotfire.com CROWN FIRE PROTECTION, INC. ATTN: JOHN ABEL 4932 WEST INTERURBAN BLVD. BOTHELL, WASHINGTON 98012 PHONE: 425-481-7669 FAX: 425 -481 -8695 E —MAIL: jabel@crownfp.com COSCO FIRE PROTECTION ATTN: PATRICK CARNAHAN 15000 WOODINVILLE — REDMOND RD. SUITE #B -800 WOODINVILLE, WASHINGTON 98072 PHONE: 425- 827 -9654 425 -686 -6313 FAX: 425 - 827 -4784 E —MAIL: pcarnahan ®coscofire.com WESTERN STATES FIRE PROTECTION CO. ATTN: WES HAMILTON 7102 180TH AVENUE NE, #A -105 REDMOND, WASHINGTON 98052 PHONE: 425 - 881 -0100 FAX: 425 - 881 -3030 E —MAIL: weston.hamilton@wsfp.com MECHANICAL CONTRACTOR'S NOTES: ALL OF THE MECHANICAL & SPRINKLER WORK IS NOT NECESSARILY SHOWN OR NOTED ON THESE DRAWINGS. THE CONTRACTORS SHALL VISIT THE JOB SITE AND VERIFY ALL EXISTING CONDITIONS RELATED TO THE WORK PRIOR TO BIDDING. THOSE ITEMS NOT SHOWN OR NOTED, BUT ARE DEEMED NECESSARY FOR REMOVAL OR RELOCATION BY THE OWNER OR HIS REPRESENTATIVE, SHALL BE PART OF THIS CONTRACT. THE SUBMISSION OF THE PROPOSALS SHALL BE CONSIDERED AS EVIDENCE THAT THE CONTRACTORS HAVE VISITED THE SITE. NO EXTRA PAYMENTS WILL BE ALLOWED, DUE TO EXTRA WORK MADE NECESSARY BY THE CONTRACTOR'S FAILURE TO VISIT THE JOB SITE. 0 r C 0 Mob -o91 3k ( d CODE COMPLIANCE IT � i QfrT APR r _ 1 s $ �g�, $,. I ��V;F� .._ r RECEIVED APR 2 2 2008 PERMIT CENTER GENERAL A. THE GENERAL CONDITIONS OF THE GENERAL SPECIFICATIONS, ALONG WITH ALL APPLICABLE INSTRUCTIONS TO BIDDERS, SHALL FORM A PART OF THIS SECTION OF THE SPECIFICATIONS. B. REFERENCE IS MADE TO REQUISITES FOR BIDDERS AND CONTRACTORS UNDER OTHER SECTIONS OF THESE SPECIFICATIONS, WHICH SHALL BE CONSIDERED BINDING, UNLESS OTHERWISE NOTED UNDER THIS SECTION. SCOPE EACH CONTRACTOR SHALL THOROUGHLY ACQUAINT HIMSELF WITH THE CONSTRUCTION DETAILS, BOTH ON TENANT CONSTRUCTION DRAWINGS AND LANDLORD'S AS REFERRED TO, BEFORE SUBMITTING HIS BID AS NO ALLOWANCES WILL BE MADE BECAUSE OF CONTRACTOR'S UNFAMILIARITY WITH THESE DETAILS. ALL PERFORMANCE OF CONSTRUCTION SHALL BE AS REQUIRED BY THE PACE OF THE GENERAL CONSTRUCTION. INSPECTION OF SITE ALL PROPOSALS SHALL PRECLUDE THAT CONTRACTOR IS FAMILIAR WITH JOBSITE CONDITIONS AND UTIUTY LOCATIONS AND THE LACK OF SPECIFIC INFORMATION ON THE DRAWINGS SHALL NOT RELIEVE THE CONTRACTOR OF ANY RESPONSIBILITY. PERMITS ALL PERMITS AND LICENSES NECESSARY FOR THE PROPER EXECUTION OF THE WORK SHALL BE SECURED AND PAID FOR BY THE SUBCON- TRACTOR INVOLVED. CODE REQUIREMENTS ALL WORK UNDER THIS CONTRACT SHALL COMPLY WITH THE PROVISIONS OF THE SPECIFICATIONS, DRAWINGS OR AS DIRECTED BY THE OWNER, AND SHALL SATISFY ALL APPLICABLE CODES, ORDINANCES, AND /OR REGULATIONS OF THE GOVERNING BODIES, WHETHER SO SHOWN OR NOT, AND ALL MODIFICATIONS REQUIRED BY SUCH AUTHORITIES SHALL BE MADE BY THE CONTRACTOR WITHOUT ANY ADDITIONAL COST TO OWNER. MATERIALS AND WORKMANSHIP A. ALL MANUFACTURED ARTICLES, MATERIALS, AND EQUIPMENT SHALL BE APPLIED AS RECOMMENDED BY THE MANUFACTURERS, AND UN- LESS OTHERWISE SPECIFIED SHALL BE NEW, AND FREE FROM ANY AND ALL DEFECTS. UKE MATERIALS USED SHALL BE OF THE SAME MANUFACTURE AND QUALITY UNLESS OTHERWISE SPECIFIED. B. ALL WORK UNDER THIS CONTRACT SHALL BE PERFORMED BY COM- PETENT WORKMEN AND EXECUTED IN A NEAT AND WORKMANLIKE MANNER. WORK SHALL BE PROPERLY PROTECTED DURING CON- STRUCTION AND COMPLETION, INSTALLATION SHALL BE THOROUGHLY CLEANED OF ALL DEBRIS PRESENT AS A RESULT OF THIS CONTRACT AND SHALL BE REMOVED FROM THE PREMISES, DQ NOT ABANDON. CODES AND REGULATIONS EACH SUBCONTRACTOR SHALL COMPLY WITH ALL LAWS, ORDINANCES, RULES AND REGULATIONS BEARING ON THE CONDUCT OF THE WORK AS DRAWN AND SPECIFIED. IF A SUBCONTRACTOR OBSERVES THAT THE DRAWINGS AND SPECIFICATIONS ARE AT A VARIANCE, HE SHALL PROMPTLY NOTIFY THE GENERAL CONTRACTOR AND THE TENANT IN WRITING. IF ANY SUBCONTRACTOR PERFORMS ANY WORK KNOWING IT TO BE CONTRARY TO LAWS, ORDINANCES, RULES AND REGULATIONS AND WITHOUT GIVING SUCH NOTICE, THE SUBCONTRACTOR SHALL BEAR ALL COSTS ARISING THEREFROM. PROTECTION OF WORK AND PROPERTY A. EACH SUBCONTRACTOR SHALL CONTINUOUSLY MAINTAIN ADEQUATE PROTECTION OF ALL HIS WORK FROM DAMAGE AND SHALL PROTECT THE OWNER'S PROPERTY FROM INJURY OR LOSS ARISING FROM HIS WORK. ANY SUCH DAMAGE, INJURY, OR LOSS, EXCEPT SUCH AS MAY BE DIRECTLY DUE TO CAUSES BEYOND HIS CONTROL AND NOT TO HIS FAULT OR NEGLIGENCE, SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR. HE SHALL ADEQUATELY PROTECT ADJACENT PROPERTY AS WELL. B. EACH SUBCONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS FOR THE SAFETY OF THEIR EMPLOYEES ON THE WORK AND SHALL COMPLY WITH ALL PROVISIONS OF FEDERAL STATE AND LOCAL BUILDING CODES AND SAFETY LAWS TO PREVENT ACCIDENTS OR INJURY TO PERSONS ON OR ADJACENT TO THE PREMISES WHERE THE WORK IS BEING PERFORMED. EACH SUBCONTRACTOR SHALL MAINTAIN ALL INSURANCE REQUIRED TO PROTECT HIMSELF, THE OWNER AND TENANT FOR THE DURATION OF THE WORK AGAINST PROPERTY DAMAGE AND PUBLIC LIABILITY. CHANGES IN THE WORK THE TENANT, WITHOUT INVALIDATING THE CONTRACT, MAY ORDER EXTRA WORK OR MAKE CHANGES BY ALTERING, ADDING TO, OR DEDUCTING FROM THE WORK, WITH CONTRACT SUM BEING ADJUSTED ACCORDINGLY. COOPERATION ALL WORK UNDER THESE SPECIFICATIONS SHALL BE ACCOMPLISHED IN CONJUNCTION WITH OTHER CONTRACTORS AND TRADES OF THIS PROJECT IN A MANNER WHICH WILL ALLOW EACH CONTRACTOR AND TRADE SUF- FICIENT TIME AT THE PROPER STAGE OF CONSTRUCTION TO FULFILL HIS CONTRACTS. CONTRACTORS SHALL CONTACT OWNER FOR INSTRUCTIONS SHOULD ANY QUESTIONS ARISE BETWEEN TRADES AS TO THE INSTALL- ATION OF LINES, DUCTS, CONDUITS, FIXTURES, OR EQUIPMENT, OR SHOULD IT APPEAR DESIRABLE TO ANY GENERAL CONSTRUCTION WHICH WOULD AFFECT THE APPEARANCE OR STRENGTH OF THE STRUCTURE. SUBSTITUTION OF MATERIALS MANUFACTURERS ARE LISTED ON PLANS TO ESTABLISH A STANDARD. THE PRODUCTS OF OTHER MANUFACTURERS WILL BE ACCEPTABLE, IF IN THE OPINION OF THE TENANT, THE SUBSTITUTE MATERIAL IS OF QUALITY EQUAL TO OR BETTER THAN THE MATERIAL SPECIFIED. AND WILL SERVE WITH EQUAL EFFICIENCY AND DEPENDABILITY, FOR THE PURPOSE OF WHICH THE ITEMS SPECIFIED WERE INTENDED. SHOP DRAWINGS SHOP DRAWINGS AND CATALOG DATA ON ALL MAJOR ITEMS OF EQUIPMENT AND SYSTEMS, AND OTHER SUCH ILLUSTRATIVE MATERIAL THAT MAY BE CONSIDERED NECESSARY BY THE TENANT, SHALL BE SUBMITTED BY THIS CONTRACTOR IN ADEQUATE TIME TO PREVENT DELAY AND /OR CON- STRUCTION MODIFICATIONS. DRAWINGS AND SPECIFICATIONS A. THE DRAWINGS DIAGRAMMATICALLY INDICATE THE LOCATIONS OF THE VARIOUS LINES, DUCTS, CONDUITS, FIXTURES, AND EQUIPMENT AND THE METHOD OF CONNECTING AND CONTROLLING THEM. IT 15 NOT INTENDED TO SHOW EVERY CONNECTION IN DETAIL AND ALL FITTINGS REQUIRED FOR A COMPLETE SYSTEM. B. SHOULD ANY CHANGES BE DEEMED NECESSARY BY THE CONTRACTOR, TO ANY ITEMS SHOWN ON CONTRACT DRAWINGS, SHOP DRAWINGS, DESCRIPTIONS, AND THE REASON FOR THE PROPOSED CHANGES SHALL BE SUBMITTED TO THE OWNER FOR APPROVAL. RESPONSIBILITY A. THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR THE SATISFACTORY AND COMPLETE EXECUTION OF ALL WORK INCLUDED IN HIS CONTRACT. HE SHALL PRODUCE COMPLETE AND FULLY OPERATIONAL SYSTEMS AND PROVIDE ALL INCIDENTAL ITEMS REQUIRED AS PART OF HIS WORK, REGARDLESS OF WHETHER SUCH ITEM IS PARTICULARLY SPECIFIED OR INDICATED. FOR EXAMPLE, ON SINK INSTALLATIONS, ESCUTCHEONS SHALL BE PROVIDED FOR COUNTERTOP PENETRATIONS, ALTHOUGH THEY WERE NOT SPECIFICALLY IDENTIFIED IN THE CONTRACT DOCUMENTS. B. CONTRACTOR SHALL SUPPLY TO LANDLORD AND TENANT A CERTIFIED AIR BALANCE REPORT AT COMPLETION OF PROJECT. THIS SHALL BE REQUIRED FOR BOTH REMODELED AND NEW STORES. HEATING. VENTILATING AND AIR CONDITIONING GENERAL A. THE WORK COVERED BY THIS SECTION OF THESE SPECIFICATIONS SHALL BE ACCOMPLISHED IN ACCORDANCE WITH THE RESPECTIVE DRAWINGS, INFORMATION OR INSTRUCTIONS TO BIDDERS, GENERAL CONDITIONS, ADDENDA, OR DIRECTIVES WHICH MAY BE ISSUED BY THE OWNER, SHALL BE COMPLIED WITH IN EVERY ASPECT. B. THE LISTING HEREIN OF AN ARTICLE OR MATERIAL, OPERATION OR METHOD, REQUIRES THAT THE CONTRACTOR SHALL FURNISH AND INSTALL EACH ITEM LISTED, UNLESS SPECIFICALLY NOTED TO THE CONTRARY. THE CONTRACTOR SHALL PERFORM EACH OPERATION PRESCRIBED OR LISTED ACCORDING TO THE CONDITIONS STATED. EXAMINATION OF SITE ALL CONTRACTORS SUBMITTING PROPOSALS FOR THIS WORK SHALL FIRST EXAMINE THE SITE AND ALL EXISTING CONDITIONS AFFECTING HIS WORK. ALL PROPOSALS SHALL SPECIFY, IN WRITING, ALL SUCH CONDITIONS THAT MAY ALTER OR AFFECT THE WORK UNDER THIS CONTRACT. SCOPE FURNISH ALL MATERIALS, EQUIPMENT, AND LABOR NECESSARY FOR A COMPLETE AND FULLY OPERATIONAL HEATING, VENTILATING, AND AIR CONDITIONING SYSTEM EXCEPT AS SPECIFICALLY EXCLUDED BY DRAWINGS AND /OR BY TENANT'S DIRECTIONS. EQUIPMENT A. PARALLEL FAN - POWERED TERNIMAL UNITS: 1. CASING - 22 -GAUGE GALVANIZED STEEL. HANGER BRACKETS, SIDE ACCESS, AND FILTER WI \HIGH IS ON THE PLENUM INLET ARE PROVIDED AS STANDARD. 2. AGENCY USTING - THE UNIT IS UL LISTED AS A ROOM AIR TERMINAL UNIT. CONTROL #9N65. ARI 880 CERTIFIED. 3. INSULATION - 1/2" MATTE -FACED INSULATION. THE INTERIOR SURFACE OF THE UNIT CASING IS ACOUSTICALLY AND THERMALLY UNED WITH 1/2 ", 1.75 LB /CU. FT DENSITY GLASS FIBER WITH A HIGH DENSITY FACING OF 4.0 LB /CU. FT. THE INSULATION R -VALUE IS 1.9. THE INSULATION IS UL LISTED AND MEETS NFPA -90A AND UL 181 STANDARDS. THERE ARE NO EXPOSED EDGES OF INSULATION (COMPLETE METAL ENCAPSULATION) 4. PRIMARY AIR VALVE - AIR VALVE ROUND. THE PRIMARY AIR INLET CONNECTION IS AN 18 -GAUGE GALVANIZED STEEL CYLINDER SIZED TO FIT STANDARD ROUND DUCT. A MULTIPLE POINT, AVERAGING FLOW SENSING RING I5 PROVIDED WITH BALANCING TAPS FOR MEASURING AIRFLOW. AN AIRFLOW VERSUS PRESURE DIFFERENTIAL CALIBRATION CHART IS PROVIDED. THE DAMPER BLADE IS CONSTRUCTED OF A CLOSED -CELL FOAM SEAL THAT IS MECHANICALLY LOCKED BETWEEN 2 22 -GAUGE GALVANIZED STEEL DISKS. THE DAMPER BLADE ASSEMBLY IS CONNECTED TO A CAST ZINC SHAFT SUPPORTED BY SELF - LUBRICATING BEARINGS. THE SHAFT IS CAST WITH A DAMPER POSITION INDICATOR. THE VALVE ASSEMBLE INCLUDES A MECHANICAL STOP TO PREVENT OVER STROKING. THE MAXIMUM LEAK RATE IS 1% AT 4" W.G. INLET STATIC PRESSURE. 5. FAN MOTOR - SINGLE SPEED, DIRECT DRIVE, PERMANENT SPLIT CAPACITOR TYPE. THERMAL OVERLOAD PROTECTION PROVIDED. MOTORS WILL BE DESIGNED SPECIFICALLY FOR USE WITH AN OPEN SCR. MOTORS WILL ACCOMMODATE ANTI - BACKWARD ROTATION AT START UP. MOTOR AND FAN ASSEMBLY ARE ISOLATED FROM TERMINAL UNIT. 6. FAN SPEED CONTROL - VARIABLE SPEED CONTROL SWITCH (SCR). THE SCR SPEED CONTROL DEVICE IS PROVIDED AS STANDARD AND ALLOWS THE OPERATOR INFINITE FAN SPEED ADJUSTMENT SO THE FAN OUTPUT MAY BE MODIFIED TO ACHIEVE EXACT CFM REQUIREMENTS. 7. TRANSFORMER - THE 50 VA TRANSFORMER IS FACTORY MOUNTED IN THE FAN CONTROL BOX TO PROVIDE 24 VAC FOR CONTROLS. 8. POWER DISCONNECT - THE POWER DISCONNECT IS PROVIDED AS STANDARD AND ALLOWS THE OPERATOR TO TURN THE UNIT ON OR OFF BY TOGGLING TO THE APPROPRIATE SETTING. THIS SWITCH BREAKS BOTH LOEGS OF POWER TO THE FAN AND THE ELECTRONIC CONTROLS )IF APPLICABLE). 9. OUTLET CONNECTION - FLANGED CONNECTION. A RECTANGULAR OPENING ON THE UNIT DISCHARGE TO ACCEPT A 90' FLANGED DUCTWORK CONNECTION. 10. FILTER - A 1" FILTER IS PROVIDED ON THE PLENUM INLET AND ATTACHES TO THE UNIT WITH A FILTER FRAME. 11. ACCESS PANEL - INTERNAL ACCESS TO UNIT IS ACHIEVED THROUGH PLENUM INLET. 12. ELECTRIC HEAT COIL - THE ELECTRIC HEATER IS FACTORY PROVIDED AND INSTALLED, UL RECOGNIZED RESISTANCE OPEN -TYPE HEATER WITH AIRFLOW SWITCH. IT ALSO CONTAINS A DISC -TYPE AUTOMATIC PILOT DUTY THERMAL PRIMARY CUTOUT, AND MANUAL RESET LOAD CARRYING THERMAL SECONDARY DEBICE. HEATER ELEMENT MATERIAL IS NICKEL - CHROMIUM. THE HEATER TERMINAL BOX IS PROVIDED WITH 7/8" KNOCKOUTS FOR CUSTOMER POWER SUPPLY. TERMINAL CONNECTIONS ARE PLATED STEEL WITH CERAMIC INSULATORS. HEATER OCNTROL ACCESS IS ON THE DISCHARGE SIDE OF THE UNIT. ELECTRIC HEAT OPTIONS: A. CONTACTORS - MAGNETIC CONTACTOR. AN ELECTRIC HEATER 24 -VOLT CONTACTOR FOR USE WITH DIRECT DIGITAL CONTROL (DDC) OR ANALOG ELECTRONIC CONTROLS. B. AIRFLOW SWITCH -- AN AIR PRESSURE DEVICE DESIGNED TO DISABLE THE HEATER WHEN THE SYSTEM FAN IS OFF. C. POWER FUSE - IF POWER FUSE IS CHOSEN WITH A UNIT WITH ELECTRIC HEAT, THEN A SAFETY FUSE LOCATED IN THE ELECTRIC HEATER'S LINE OF POWER TO PREVENT POWER SURGE DAMAGE TO ELECTRIC HEATER. 13. UNIT CONTROLS SEQUENCE OF OPERATION - THE UNIT CONTROLLER CONTINUOUSLY COMITORS THE ZONE TEMPERATURE AGAINST ITS SETPOINT AND VARIES THE PRIMARY AIRFLOW AS REQUIRED TO MEET ZONE SETPOINTS. AIRFLOW IS LIMITED BY MINIMUM AND MAZIMUM POSITION SETPOINTS. FOR A PARALLEL UNIT, THE CONTROLLER WILL INTERMITTENTLY START THE FAN UPON A CALL FOR HEAT. UPON A FURTHER CALL FOR HEAT, ANY HOT WATER OR ELECTRIC HEAT ASSOCIATED WITH THE UNIT I5 ENABLED. 14. ANALOG ELECTRONIC CONTROLS A. ANALOG ACTUATOR - A TRANE 3 -WIRE, 24 VAC FLOATING -POINT CONTROL ACTUATOR WITH LINKAGE RELEASE BUTTON. TORQUE IS 35 IN -LB MINIMUM AND IS NON- SPRING RETURN WITH A 90- SECOND DRIVE TIME. TRAVEL IS TERMINATED BY END STOPS AT FULLY OPENED AND CLOSED POSITIONS. AN INTEGRAL MAGNETIC CLUTCH EUMINATES MOTOR STALL. B. ANALOG ELECTRONIC CONTROLLER - THE CONTROLLER CONSISTS OF A CIRCUIT BOARD THAT OFFERS BASIC VAV UNIT OPERATION AND ADDITIONAL OVERRIDE FUNCTIONS AND OPERATED USING 24 VAC POWER. THE CONTROLLER USED A CAPACITIVE TYPE PRESSURE TRANSDUCER TO MAINTAIN CONSISTENT AIR DELIVERY REGARDLESS OF SYSTEM PRESSURE CHANGES. THE ENCLOSURE HAS 7/8" KNOCKOUTS FOR REMOTE CONTROL WIRING. A TRANE ELECTRONIC ZONE SENSOR I5 REQUIRED. C. ANALOG ELECTRONIC THERMOSTAT - THIS SINGLE-TEMPERATURE, WALL - MOUNTED ELECTRONIC DEVICE UTILIZES A THERMISTOR TO VARY THE VOLTAGE OUTPUT IN RESPONSE TO CHANGES IN THE ZONE TEMPERATURE. CONNECTIONS TO THE VAV UNIT CIRCUIT BOARD ARE MADE USING STANDARD THREE - CONDUCTOR THERMOSTAT WIRE. THE SETPOINT. THE OTHER MODEL HAS AN EXTERNALLY ADJUSTABLE 2 MODELS. ONE MODEL HAS A CONCEALED, INTERNALLY ADJUSTABLE SETPOINT ADJUSTMENT RANGE IS 63 -85'F. THE SENSOR IS AVAILABLE IN SETPOINT. ELECTRIC HEAT OPTIONS: A. CONTACTORS - MAGNETIC CONTACTOR. AN ELECTRIC HEATER 24 -VOLT CONTACTOR FOR USE WITH DIRECT DIGITAL CONTROL (DDC) OR ANALOG ELECTRONIC CONTROLS. B. AIRFLOW SWITCH - AN AIR PRESSURE DEVICE DESIGNED TO DISABLE THE HEATER WHEN THE SYSTEM FAN IS OFF. C. POWER FUSE - IF POWER FUSE IS CHOSEN WITH A UNIT WITH ELECTRIC HEAT, THEN A SAFETY FUSE LOCATED IN THE ELECTRIC HEATER'S UNE OF POWER TO PREVENT POWER SURGE DAMAGE TO ELECTRIC HEATER. 13. UNIT CONTROLS SEQUENCE OF OPERATION - THE UNIT CONTROLLER CONTINUOUSLY MONITORS THE ZONE TEMPERATURE AGAINST ITS SET POINT AND VARIES THE PRIMARY AIRFLOW AS REQUIRED TO MEET ZONE SET POINTS. AIRFLOW IS LIMITED BY MINIMUM AND MAXIMUM POSITION SET POINTS. FOR A PARALLEL UNIT, THE CONTROLLER WILL INTERMITTENTLY START THE FAN UPON A CALL FOR HEAT. UPON A FURTHER CALL FOR HEAT, ANY HOT WATER OR ELECTRIC HEAT ASSOCIATED WITH THE UNIT IS ENABLED. 14. ANALOG ELECTRONIC CONTROLS A. ANALOG ACTUATOR - A TRANE 3 -WIRE, 24 VAC FLOATING -POINT CONTROL ACTUATOR WITH LINKAGE RELEASE BUTTON. TORQUE IS 35 IN-LB MINIMUM AND IS NON- SPRING RETURN WITH A 90- SECOND DRIVE TIME. TRAVEL IS TERMINATED BY END STOPS AT FULLY OPENED AND CLOSED POSITIONS. AN INTEGRAL MAGNETIC CLUTCH EUMINATES MOTOR STALL. B. ANALOG ELECTRONIC CONTROLLER - THE CONTROLLER CONSISTS OF A CIRCUIT BOARD THAT OFFERS BASIC VAV UNIT OPERATION AND ADDITIONAL OVERRIDE FUNCTIONS AND OPERATED USING 24 VAC POWER. THE CONTROLLER USED A CAPACITIVE TYPE PRESSURE TRANSDUCER TO MAINTAIN CONSISTENT AIR DELIVERY REGARDLESS OF SYSTEM PRESSURE CHANGES. THE ENCLOSURE HAS 7/8" KNOCKOUTS FOR REMOTE CONTROL WIRING. A TRANE ELECTRONIC ZONE SENSOR IS REQUIRED. C. ANALOG ELECTRONIC THERMOSTAT - THIS SINGLE- TEMPERATURE, WALL - MOUNTED ELECTRONIC DEVICE UTILIZES A THERMISTOR TO VARY THE VOLTAGE OUTPUT IN RESPONSE TO CHANGES IN THE ZONE TEMPERATURE. CONNECTIONS TO THE VAV UNIT CIRCUIT BOARD ARE MADE USING STANDARD THREE - CONDUCTOR THERMOSTAT WIRE. THE SET POINT. THE OTHER MODEL HAS AN EXTERNALLY ADJUSTABLE 2 MODELS. ONE MODEL HAS A CONCEALED, INTERNALLY ADJUSTABLE SET POINT ADJUSTMENT RANGE IS 63- -857. THE SENSOR IS AVAILABLE IN SET POINT. • C. EXHAUST FANS 1. COMBINATION EXHAUST FAN /LIGHT SUPPLIED & INSTALLED BY HVAC CONTRACTOR (TYPICAL OF 2). TEIBER MODEL #TFL9OL, 4 "0 DUCT SIZE, 165 W, 90 CFM, 2.0 SONES, 120v /1ph /60hz. PROVIDE BACKDRAFT DAMPER. D. ALL VAVS SHALL BE EQUIPPED WITH PROGRAMMABLE THERMOSTAT SENSOR CAPABLE OF BEING ADJUSTED TO 55'F HEATING AND 85'F COOUNG. DESIGN AND STANDARD CONDITIONS FOR THERMOSTAT OPERATION SHALL BE AS FOLLOWS: COOLING: 75T MAXIMUM OCCUPIED COOLING TEMPERATURE 85T COOLING NIGHT SETBACK. HEATING: 70'F MAXIMUM OCCUPIED HEATING TEMPERATURE 60T HEATING NIGHT SETBACK. FAN: CONTINUOUS IN OCCUPIED AND RECOVERY MODE AND WITH HEATING OR COOUNG EQUIPMENT IN UNOCCUPIED MODE. DEADBAND: CAPABLE OF MAINTAINING A 57 DEADBAND. CLOCK: 7 DAY CAPABLE OF 7 DIFFERENT DAY SCHEDULES. OVERNIGHT: HAVE A 2 HOUR OVERRIDE ACCESSIBLE TO MANAGER. BACKUP: CAPABLE OF MAINTAINING PROGRAMMED SETTING FOR AT LEAST 10 HOURS WITHOUT POWER. DUCTWORK A. SQUARE /RECTANGULAR DUCTWORK SHALL BE CONSTRUCTED OF NEW GALVANIZED PRIME GRADE SHEET STEEL B. ROUND DUCTWORK SHALL BE CONSTRUCTED OF NEW GALVANIZED PRIME GRADE SHEET STEEL. ALL 90 DEGREE ELBOWS FOR ROUND DUCTWORK SHALL BE FIVE (5) PIECE. ALL LONGITUDINAL SEAMS SHALL BE FORMED BY PITTSBURGH LOCKS. JOINTS SHALL BE SWAGGED WITH ONE -HALF INCH (1/2 ") OVERLAP_ C. ALL SUPPLY AIR DUCTS, RETURN AIR DUCTS AND OUTSIDE AIR DUCTS SHALL BE GALVANIZED STEEL WITH 2.5" THICK (MIN. R -7) .75 PCF EXTERNAL ACOUSTICAL AND THERMAL INSULATION. 1. ALL JOINTS, LONGITUDINAL AND TRANSVERSE SEAMS, AND CONNECTIONS IN DUCTWORK MUST BE SECURELY SEALED USING WELDMENTS; MECHANICAL FASTENERS WITH SEALS, GASKETS, OR MASTICS; MESH AND MASTIC SEALING SYSTEMS; OR TAPES. TAPES AND MASTICS MUST BE LISTED AND LABELED IN ACCORDANCE WITH UL 181A OR UL 181B. ALL LONGITUDINAL AND TRANSVERSE JOINTS, SEAMS AND CONNECTIONS OF SUPPLY AND RETURN DUCTS OPERATING AT STATIC PRESSURES LESS THAN OR EQUAL TO 2" W.G. SHALL BE SECURELY FASTENED AND SEALED WITH WELDS GASKETS, MASTICS (ADHESIVES), MASTIC- PLUS - EMBEDDED FABRIC SYSTEMS OR TAPES INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. 2. MECHANICAL FASTENERS AND SEALS, MASTICS, OR GASKETS MUST BE USED WHEN CONNECTING DUCTS TO FANS AND OTHER AIR DISTRIBUTION EQUIPMENT. D. FLEXIBLE AIR DUCT FOR CONNECTIONS BETWEEN S.M. DUCT AND DIFFUSER SHALL BE AIR DUCT LISTED BY UNDERWRITERS LABORATORIES UNDER UL STANDARD 181 AS A CLASS 1 FLEXIBLE AIR DUCT AND COMPLYING WITH NFPA STANDARDS 90A AND 90B. DUCT SHALL BE FACTORY MADE AND COMPOSED OF A CPE LINER DUCT PERMANENTLY BOUNDED TO A COATED SPRING STEEL WIRE HELIX AND SUPPORTING A FIBER GLASS INSULATING BLANKET. R. -7.0 LOW PERMEABILITY OUTER VAPOR BARRIER OF FIBER GLASS REINFORCED FILM LAMINATE SHALL COMPLETE THE COMPOSITE. E. CONTRACTOR SHALL SUPPLY AND INSTALL INSECT SCREENS ON ALL DUCT OPENINGS WHICH TERMINATE OUTDOORS. INSECT SCREENS SHALL BE 10 GAUGE, ONE -HALF INCH (1/2 ") MESH IN REMOVABLE GALVANIZED STEEL FRAMES. F. ALL DUCTWORK SHALL BE DESIGNED IN ACCORDANCE WITH THE PROCEDURES DESCRIBED IN THE LATEST EDITION OF THE AMERICAN SOCIETY OF HEATING REFRIGERATION AND AIR CONDITIONING ENGINEERS GUIDE (ASHRAE), FABRICATED AND INSTALLED IN ACCORDANCE WITH THE METHODS RECOMMENDED IN THE SHEET METAL AND AIR CON- DITIONING CONTRACTORS NATIONAL ASSOCIATION ( SMACNA) HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE HANGERS AND_ SUPPORTS A. ALL HORIZONTAL DUCTS HAVING A DIMENSION OF 40 INCHES AND LESS SHALL BE SUPPORTED BY MEANS OF BAND IRON HANGERS OF NO. 18 U.S. GAUGE ATTACHED TO DUCT BY MEANS OF RIVETS, SCREWS OR CLAMPS, AND FASTENED TO STRUCTURE ABOVE BY TOGGLE BOLTS OR OTHER MEANS. EACH SECTION OF DUCTWORK SHALL HAVE AT LEAST ONE PAIR OF SUPPORTS. VERTICAL DUCTS SHALL BE SUPPORTED WITH 1-1/4" x 1-1/4" x 1-1/4" ANGLES AT FLOOR PENETRATIONS. B. ALL HORIZONTAL DUCTS HAVING A DIMENSION OF 40 INCHES AND MORE SHALL BE SUPPORTED BY MEANS OF ANGLE IRON TRAPEZE HANGERS. EACH SECTION OF DUCTWORK SHALL HAVE AT LEAST ONE PAIR OF SUPPORTS. FLASHING A. CONTRACTOR SHALL PROVIDE WATER TIGHT 24 GA. SHEET METAL FLASHINGS AT ALL EXTERIOR WALLS AND ROOF PENETRATIONS. B. ALL CUTTING OF ROOF OPENINGS, SUPPORTS FOR ROOF OPENINGS, PITCH PANS, ROOF CURBS, FLASHINGS, COUNTER FLASHINGS, REPAIR TO ROOF, ETC. ASSOCIATED WITH HVAC SUBCONTRACTOR SHALL BE INCLUDED IN THE RESPONSIBILITY OF THE HVAC SUBCONTRACTOR. HE SHALL EMPLOY THE LANDLORD'S ROOFERS FOR THIS WORK TO MAINTAIN THE ROOF WARRANTY. DAMPERS A. SPUTTER DAMPERS SHALL BE FABRICATED OF SHEET STEEL NOT LESS THAN NO. 16 U.S. GAUGE WITH THE LEADING EDGE HEMMED. EACH DAMPER TO BE SIZED ADEQUATELY TO COVER THE SMALLER OF THE TWO OPENINGS IT CONTROLS. DAMPERS SHALL BE CONTROLLED AS FOLLOWS: EXPOSED OR ACCESSIBLE DUCTWORK - LOCKING QUADRANTS EQUAL TO YOUNG REGULATOR NO. 1 WITH DAMPER ROD END BEARINGS ON OPPOSITE END. CONCEALED DUCTWORK - LOCKING QUADRANT EQUAL TO YOUNG REGULATOR NO. 315 (CHROMIUM PLATED WITH DAMPER ROD END BEARINGS ON BOTH ENDS). B. VOLUME DAMPERS SHALL BE OF THE OPPOSED INTERLOCKING TYPE AS MANUFACTURED BY AMERICAN FOUNDRY AND FURNACES CO. (AFFC0) OR EQUAL. BLADES SHALL BE OF NO, 16 GAUGE SHEET METAL AND SHALL NOT EXCEED 48" IN LENGTH OR 12" IN WIDTH. BLADES SHALL BE ON ONE -HALF INCH (1/2 ") DIAMETER RUSTPROOF AXLE. BEARINGS TO BE OF THE SELF - LUBRICATING FERRULE TYPE. C. FIRE DAMPERS SHALL BE SUPPLIED AND INSTALLED BY HVAC CON- TRACTOR AT DUCT PENETRATIONS IN ARE RATED WALLS, FLOORS, CEILINGS AND ROOF AS REQUIRED. COORDINATE WITH LANDLORD, LOCAL FIRE MARSHALL AND ALL CODES AND GOVERNING AUTHORITIES HAVING JURISDICTION. D. FIELD FABRICATED TURNING VANES SHALL BE ACCEPTABLE IN SQUARE ELBOWS. PROVIDE AND INSTALL BARBER - COLMAN AIRTURNS OR EQUAL. TURNING VANES SHALL BE OF THE SAME GAUGE METAL AS THE DUCT IN WHICH THEY ARE INSTALLED. RADIUS ELBOWS SHALL HAVE A CENTER UNE RADIUS OF ONE AND ONE -HALF (1 -1/2) TIMES THE DUCT WIDTH. DUCTWORK - EXCEPTIONS DUCTWORK FOR EXHAUST OR OUTSIDE SUPPLY AIR SHALL BE ALL METAL AND CONSTRUCTED ACCORDING TO RECOMMENDED PRACTICES OF THE LATEST ISSUE OF ASHRAE. SUPPORT OF DUCT SYSTEM HANGER DESIGN SHALL BE AS DESCRIBED IN THE LATEST EDITION OF THE "SMACNA" MANUAL. REINFORCEMENT MEMBERS MAY BE USED TO SUPPORT DUCT SYSTEM PROVIDED DETAILS OUTLINED IN THE "SMACNA" MANUAL ARE ADHERED TO. DUCTS SHALL BE SUPPORTED AT ALL TURNS AND TRANSITIONS AND NOT MORE THAN 8' -0" O.C. STRAIGHT DUCTS UP TO 59" MAX. DIMENSIONS SHALL BE SUPPORTED 6' -0" O.C. DUCTS OVER 60" MAX. DIMENSIONS SHALL BE SUPPORTED AT 4' -O" O.C. REINFORCEMENT ALL DUCTS SHALL BE REINFORCED ACCORDING TO THE LATEST EDITION OF SMACNA MANUAL. MATERIALS FOR REINFORCEMENT MEMBERS SHALL BE GALVANIZED STEEL. ALL SCREWS AND WASHERS SHALL BE PLATED OR GALVANIZED. TESTING AND ADJUSTING CONTRACTOR SHALL DEMONSTRATE OPERATION OF SYSTEM TO FULL SATISFACTION OF TENANT, SHALL BALANCE AIR FLOW IN ACCORDANCE WITH AIR QUANTITIES ON DRAWINGS AND SHALL RECORD VOLUME READINGS IN ACCORDANCE WITH ASHRAE AND PROVIDE SAME TO TENANT. GUARANTEE ALL MATERIALS, EQUIPMENT, AND WORKMANSHIP SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR AFTER DATE OF ACCEPTANCE. THE COMPLETED SYSTEM SHALL BE FULLY OPERATIONAL AND ACCEPTANCE BY TENANT SHALL BE A CONDITION OF THIS CONTRACT. ALL WORK FOUND TO BE DEFECTIVE SHALL BE REPAIRED OR REPLACED BY THIS SUBCONTRACTOR WITHOUT ADDITIONAL COST TO THE TENANT. ACCESSORY ITEMS ALL MANUAL DAMPERS, FIRE DAMPERS, TURNING VANES, REGISTER CON- NECTIONS, ACCESS DOORS OR OTHER ASSOCIATED ACCESSORIES SHALL BE INSTALLED ACCORDING TO THE LATEST EDITION OF "SMACNA" MANUAL. SPRINKLER SYSTEM A. SHOP DRAWINGS ---THE SPRINKLER CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO THE TENANT'S LANDLORD AND TO THE APPROPRIATE AUTHORITIES AND INSURANCE UNDERWRITER FOR THEIR APPROVAL. A COPY OF THE APPROVAL LETTER FROM THESE AUTHORITIES SHALL BE FORWARDED TO THE TENANT, LANDLORD AND DESIGN ARCHITECT. B. SPRINKLER HEAD TYPES SHALL BE AS FOLLOWS: 1. STORE FRONT: CONCEALED, PAINT COVER PLATE TO MATCH CEILING 2. NON- PUBLIC AREAS WITH CEIUNGS: CHROME PEDANT 3. PUBLIC AREAS WITH CEIUNGS: CONCEALED, PAINT COVER PLATE TO MATCH CEILING NOTE FOR GENERAL CONTRACTOR; IT IS THE RESPONSIBILITY OF THE TENANT'S GENERAL CONTRACTOR TO MAKE USE OF APPLICABLE NOTES AND SPECIFICATIONS LISTED ON THIS SHEET AS THEY MAY PERTAIN TO THE SPECIFIC JOB. LANDLORD'S NOTES ALL SPRINKLERS IN THE PUBLIC ZONE OF THE SPACE SHALL BE FULLY RECESSED WITH COVER PLATES. SPRINKLER LAYOUT AND PIPE SIZING: SHALL BE HYDRAULICALLY DESIGNED ACCORDING TO ORDINARY HAZARD GROUP 2 AND THE LATEST REQUIREMENTS OF NFPA 13. ALL TENANT MECHANICAL WORK SHALL CONFORM TO 2006 INTERNATIONAL MECHANICAL CODE. ROOF JOIST HANGER WIRE M 0S I SHEET MTL. DUCT HANGER RECTANGULAR DUCT ROOF JOIST HANGER WIRE SHEET MTL. DUCT HANGER SPIRAL DUCT DUCT HANGING DETAILS SCALE NONE LANDLORD'S SUPPLY AIR DUCT MAIN H.P. FLEX DUCT MAX. 1' -0" 115V WIRING & J-BOX BY ELECTRICAL CONTRACTOR J -BOX r * THERMOSTAT WIRING J 1 BY HVAC CONTRACTOR MEDIUM TO HIGH PRESSURE DUCT ELECTRONIC DAMPER OPERATOR * FOLLOW MANUFACTURER'S WIRING DIAGRAM ROOM THERMOSTAT HANGERS (TYP. OF 4) VAV BOX VAV BOX CONNECTION DETAIL BEAM x N CLEVIS HANGER OVERSIZED FOR INSULATION WITH 18" ROLLED SLEEVE FOR SUPPORT 180' BEAM CLAMP 3/4" 1 1 1/4" 1 " 1/2" 2 2 1/2" 3 3 1/2" 5" 4" 6 " 8" 10" 12" 14" 16" 18" 20" 24 PIPE HANGER DETAIL WALE rarE HANGER SPACING AND ROD SIZE PIPE MAX SIZE ROD SPAN SIZE 7' 3/8" 7' 3/8" 7 ' 3/8 " 7' 3/8" 9' 3/8" 10' 3/8" 11' 1/2" 12' 1/2" 13' 1/2" 14' 5/8" 16' 5/8" 17' 3/4" 19' 3/4" 22' 7/8" 23' 7/8" 25' 1 27' 1" 28' 1" 30' 1 1/4" 32' 1 1/4" 2" WIDE MIN. DUCT STRAP 48" 0.C. MAX. RIGID ROUND METAL DUCT EXTERNALLY INSULATED RIGID ROUND DUCT ELBOW EXTERNALLY INSULATED INSULATED FLEXIBLE DUCT MAX. LENGTH 5' -0 ". FIRE DAMPER (LOCATION D) WHEN VOLUME DAMPER (FOR FINAL BALANCE ADJUSTMENT) SPIN -IN FITTING WITH BALANCING DAMPER AND 45' EXTRACTOR (DAMPER USED FOR ROUGH BALANCING) HVAC DUCTWORK DETAIL SCALE NONE FAN EXHAUST GRILLE CONNECT TO LANDLORD'S TOILET EXHAUST DUCT STUB -IN. REFER TO KEYED NOTES. 1" INSULATED BOX CEILING TOILET EXHAUST DETAIL BACKDRAFT DAMPER REVIEW ODE COMP APPR APR 1 6, 20 IL DIN DIVISION RECEIVER MAR 2 7 2005 PERMIT CENTS: M200 a 0 0 Cl_ 0) Q 0 Z Q 0 w