HomeMy WebLinkAboutPermit M08-092 - LEGACY PARTNERSLEGACY PARTNERS
16400 SOUTHCENTER PY
M08 -092
Parcel No.:
Address:
Suite No:
CitAbf Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
2623049021
16400 SOUTHCENTER PY TUKW
Tenant:
Name: LEGACY PARTNERS
Address: 16400 SOUTHCENTER PY , TUKWILA WA
Owner:
Name: LEGACY PARTNERS I TUKWILA L
Address: 10655 NE 4TH ST #812 , BELLEVUE WA
Contact Person:
Name: SHANNON BUCKINGHAM
Address: 5108 D ST NW , AUBURN WA
Contractor:
Name: EMERALD AIRE INC.
Address: 22043 68TH AVENUE SOUTH , KENT, WA
Contractor License No: EMERAAI055BL
Value of Mechanical: $23,000.00
Type of Fire Protection:
Furnace: <100K BTU
>100K BTU
Floor Furnace
Suspended/Wall/Floor Mounted Heater
Appliance Vent
Repair or Addition to Heat/Refrig /Cooling System....
Air Handling Unit <10,000 CFM
>10,000 CFM
Evaporator Cooler
Ventilation Fan connected to single duct
Ventilation System
Hood and Duct
Incinerator: Domestic
C ommercial/Industrial
doc: I MC -10/06
MECHANICAL PERMIT
EQUIPMENT TYPE AND QUANTITY
0
0
0
0
0
0
2
0
0
0
0
0
0
0
* *continued on next page **
M08 -092
Permit Number:
Issue Date:
Permit Expires On:
Phone:
Phone: 253 - 872 -5665
Phone: 206 872 -5665
Expiration Date: 04/01/2009
DESCRIPTION OF WORK:
INSTALL (2) NEW CLIMATE MASTER HEAT PUMPS. CAP AND REWORK EXISTING DUCTWORK TO
CREATE 2 SEPARATELY ZONED TENANT SPACES
M08 -092
04/16/2008
10/13/2008
Fees Collected: $428.75
International Mechanical Code Edition: 2006
Boiler Compressor:
0-3 HP /100,000 BTU 0
3 -15 HP /500,000 BTU 0
15 -30 HP /1,000,000 BTU.. 0
30 -50 HP /1,750,000 BTU.. 0
50+ HP /1,750,000 BTU 0
Fire Damper 0
Diffuser 0
Thermostat 0
Wood/Gas Stove 0
Water Heater 0
Emergency Generator 0
Other Mechanical Equipment
Printed: 04 -16 -2008
Permit Center Authorized Signature:
Signature:
Print Name: e�
doc: IMC -10/06
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting oft s permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or th performanc - = I ant authorized to sign and obtain this mechanical permit.
11477)
Permit Number: M08 -092
Issue Date: 04/16/2008
Permit Expires On: 10/13/2008
Date: 4-‘,6-or
Date: q /lli y
This permit shall become null and void if the work is no't.o6mmenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
M08 -092 Printed: 04 -16 -2008
Parcel No.: 2623049021
Address:
Suite No:
Tenant:
doc: Cond -10/06
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
16400 SOUTHCENTER PY TUKW
LEGACY PARTNERS
1: ** *BUILDING DEPARTMENT CONDITIONS * **
PERMIT CONDITIONS
Permit Number:
Status:
Applied Date:
Issue Date:
M08 -092
ISSUED
03/27/2008
04/16/2008
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
this requirement.
7: Manufacturers installation instructions shall be available on the job site at the time of inspection.
8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila
Permit Center.
9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the
following concerns:
12: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned
in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051)
13: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be
equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the
air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors
shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the
manufacturer's installation instructions. (IMC 606.1, 606.2.1)
M08 -092 Printed: 04 -16 -2008
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
14: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051)
15: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051)
16: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire
Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC
104.2)
17: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051)
18: Local U.L. central station supervision is required. (City Ordinance #2051)
19: The installation of wiring and equipment shall be in accordance with N.F.P.A. 70, Article 760, Fire Protective
Signaling Systems. (NFPA 72- 1.3.3)
20: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of
such condition or violation.
21: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and
#2051)
22: To schedule all construction fire - related inspections send an e -mail to fireinsprequest @ci.tukwila.wa.us. Include your
name, telephone number, permit number, project name and address and type of inspection requested.
23: These plans were reviewed by Inspector 514. If you have any questions, please call Tukwila Fire Prevention Bureau at
(206)575 -4407.
doc: Cond - 10/06
* *continued on next page **
M08 -092 Printed: 04 -16 -2008
• •
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work
construction or the performance of work.
doc: Cond - 10/06 M08 - 092
Date: y /70 /W
ordinances governing
or local laws regulating
Printed: 04 -16 -2008
Tenant Name:
Name:
•
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.ci.tukwila.wa.us
Building Permit No. t
Mechanical Permit No. MO tO ) - 4 9
Plumbing/Gas Permit No.
Public Works Permit No.
Project No.
(For office use only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
'`' King Co Assessor's Tax No.:
Site Address: 1.LD' O0 u A S uite Number:
aG a30(1'6a -I
Floor:
New Tenant: ❑ Yes
Owners Name:_ ,Q C ( 3 -
Mailing Address: /Of/ 5.5
o
an non 5��8 ' cd cil' h
Si' /� 1 3U
Mailing Address/ `� `� , VG
E -Mail Address ` / • A •• - •
City
State
Zip
CONTACT PERSON - who do we contact when your permit is ready to be issued
Day Telephone: 072' 6 6 4 , (Y), cirool
Citthafr) /.6y4 City State
, i P . ,
Fax Number: 0253' 87425 79 •/
GENERAL CONTRACTOR INFORMATION -
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
Company Name:
Mailing Address:
State
Zip
City
Contact Person: Day Telephone:
E -Mai • • ' ress: Fax Number:
ontractor Registration Number: Expiration Date:
ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record
Company Name:
Mailing Addr- :.
State
Zip
City
C s • •: ct Person: Day Telephone:
E -Mail Address: Fax Number:
ENGINEER OF RECORD All plans must be wet stamped by Engineer of Record
Company Name:
Mailing Address
City
Cont. ' erson: Day Telephone:
- -Mail Address: Fax Number:
Q: Wpplications\Forms- Applications On Line\3 -2006 - Permit Application.doc
Revised: 9-2006
bh
State
Zip
Page 1 of 6
Unit Type:
Qty
Unit Type:
Qty
Unit Type:
Qty
Boiler /Compressor:
Qty
Furnace <100K BTU
Air Handling Unit >10,000
CFM
Fire Damper
0 -3 HP /100,000 BTU
Furnace >100K BTU
Evaporator Cooler
Diffuser
3 -15 HP /500,000 BTU
Floor Furnace
Ventilation Fan Connected
to Single Duct
Thermostat
15 -30 HP /1,000,000 BTU
Suspended/Wall/Floor
Mounted Heater
Ventilation System
Wood/Gas Stove
30 -50 HP /1,750,000 BTU
Appliance Vent
Hood and Duct
Emergency
Generator
50+ HP /1,750,000 BTU
Repair or Addition to
Heat/Refrig /Cooling
System
Incinerator - Domestic
Other Mechanical
Equipment
Air Handling Unit
<10,000 CFM
2.
Incinerator — Comm/Ind
Company Name:
Mailing Address:
Use: Residential:
Commercial:
oloik
MECHANICAL PERMIT INFORMATION 206- 431 -3670
MECHANICAL CONTRACTOR INFORMATION
Contact PersonS-hetnnd !A f
E -Mail Address ay - )77 , o i&er e.-e i ►.�i &Lire .ecrr
Contractor Registration Number: 7176 gipPs J , C_
Valuation of Mechanical work (contractor's bid price): $ Z3 ,coo
Scope of Work (please provide detailed information): FE nil ( DE 4 T.At.TiAt L (Z co.) NF,14
cUMPVTEMA5 (FAT PQMP' cpp AALD R WORK- Ex i ST?u
DucT - To CEA7 E SEP FTL'1 Zo%(FO 1 Abals(T
5 PAc ES
New .... ❑ Replacement .... ❑
New ..., Replacement .... El
Fuel Type: Electric El Gas Other:
Indicate type of mechanical work being installed and the quantity below:
Q:\Applications\Forms- Applications On Line\3 -2006 - Permit Application.doc
Revised 9 -2006
bh
City State Zip
Day Telephone: O?'5& a te ! o; X (
Fax Number: 0 253 7 5 9'
`/
Expiration Date: /C
Page 4 of 6
I Date Application Accepted:
BUILDING OW ER OR AUTHORIZED AGENT:
Signature:
Print Name: Q/ /J�i ��: 1/ � a/Y)
Mailing Address: c9O 8 ,77 SJf Aid
Q: Applications\Fo`ms- Applications On Line\3 -2006 - Permit Application.doc
Revised: 9 -2006
bh
PERMIT APPLICATION NOTES — Applicable to all permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
Day
City / )
Date: 3Jt o1or
k5 $7a Sul f
qhVi O /
s tate Zip
Date Application Expires: Q `), 740 (1/
Staff Initials: •
Page 6 of 6
Receipt No.: R08 - 00943
Initials: WER
User ID: 1655
Payee: EMERALD AIRE
ACCOUNT ITEM LIST:
Description
MECHANICAL - NONRES
PLAN CHECK - NONRES
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 2623049021 Permit Number: M08 -092
Address: 16400 SOUTHCENTER PY TUKW Status: PENDING
Suite No: Applied Date: 03/27/2008
Applicant: LEGACY PARTNERS Issue Date:
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 1148 428.75
Account Code Current Pmts
000.322.102.00.0 343.00
000/345.830 85.75
Total: $428.75
Payment Amount: $428.75
Payment Date: 03/27/2008 02:51 PM
Balance: $0.00
T1. 03/27 1719 TOTAL 428.7s
doc: Receiot -06 Printed: 03 -27 -2008
Project:
keel V &I
+4
Type of Ins ection:
t K144-4
.
I Address:
Io 9DV 511ithof ti1
Date Called:
pLi
Special Instructions: A�
La 1 Z P AA
LA
Datd Wanted:
a.m.
Requester:
Phone No:
,
,w ^
_
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
PERMIT NO.
(206)431 -3670
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
( &ip f e
P
Inspec
OkA
Date: i(
$58.00 REINSPECTION FEE REQl11RED. Prior o inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection.
Receipt No.:
Date:
. -
.
Probe
Type of Ins se t'• I
Ad ress:
D,jte a e
Special Instructions:
v3� "2 2
S� A ^ o
Z S3 - S 1 (A tfiS
.. 1 1-7
Dat Want 43 _
e
Requester:
Phone No:
cbl -669
41
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
/105.490--
\)
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION fir'
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Approved per applicable codes. ❑ Corrections required prior to approval.
COMMENTS:
tJA 1 .. J h
r:
Date: s -- (, - d
$58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection.
Receipt No.:
Date:
_± .
ACTIVITY NUMBER: M08 -092 DATE: 03 -27 -08
PROJECT NAME: LEGACY PARTNERS
SITE ADDRESS: 16400 SOUTHCENTER PY
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # After Permit Issued
DEPARTMENTS:
Building 1 'vision
on
Public Works
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROIOTING:
Please Route
Documents/routing slip.doc
2 -28 -02
• •
PLAN REVIEW /ROUTING SLIP
514 AtiO
Fire Prevention
Structural
Incomplete
Structural Review Required
o
Planning Division
❑ Permit Coordinator
DUE DATE: 04 -01 -08
Not Applicable
❑ No further Review Required
REVIEWER'S INITIALS: DATE:
DUE DATE: 04 -29-08
E
APPROVALS OR CORRECTIONS:
Approved ❑ Approved with Conditions I4 Not Approved (attach comments) ❑
Notation:
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
License Information
License
EMERAAI055BL
Licensee Name
EMERALD AIRE INC
Licensee Type
CONSTRUCTION CONTRACTOR
UBI
600591552
Ind. Ins. Account Id
VICE
PRESIDENT
Business Type
CORPORATION
Address 1
5108 D STREET NW
Address 2
06/01/2000
City
AUBURN
County
KING
State
WA
Zip
98001
Phone
2538725665
Status
ACTIVE
Specialty 1
GENERAL
Specialty 2
UNUSED
Effective Date
1/13/1995
Expiration Date
4/1/2009
Suspend Date
Separation Date
Parent Company
Previous License
SOUNDAI158OW
Next License
Associated License
Business Owner Information
Name
Role
Effective
Date
Expiration
Date
HAPPE, DOUGLAS A
PRESIDENT
01/01/2000
RIDGE, JOHN P
VICE
PRESIDENT
01/01/2000
RICHARDS, RON
SECRETARY
01/13/1995
06/01/2000
TREMAINE, DAVIS
WRIGHT
AGENT
01/13/1995
12/31/1999
DUPUIS - FRICKE, LINDA
PRESIDENT
01/13/1995
12/31/1999
HAPPE, DOUGLAS A
PRESIDENT
01/13/1995
12/31/1999
Look Up a Contractor, Electriian or Plumber License Detail
Washington State Department of Labor and Industries
General/Specialty Contractor
A business registered as a construction contractor with L &I to perform
construction work within the scope of its specialty. A General or Specialty
construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
•
Page 1 of 2
https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= EMERAAI055BL 04/16/2008
HEAT PUMP SCHEDULE
TAG
MANUF.
MODEL
CLG MBH
HTG MBH
CFM
BLOWER
HP
S.P.
VOLTS
FIA
WEIGHT
HP -101
COMMAND -AIR
SWPH -404
47.9
59.8
1500
1/3
460/3
9,3
384
HP -102
COMMAND -AIR
SWPH- 254
30.6
44.4
1000
1/4
460/3
6.2
276
HP -102A
CLIMATEMASTER
GRH024AEC39RBS
l
23.0
27.6
830
1/3
277/1
10.4
193
HP -103
CLIMATEMASTER
HS -036
35.4
51.3
1200
1/2
.3"
460/3
7.6
260
HP -104
COMMAND -AIR
SWPH -254
30.6
44.4
1000
1/4
460/3
6.2
276
HP -105
COMMAND -AIR
_
SWPH -204
24.4
35.3
800
1/6
460/3
5.3
252
HP -106
COMMAND -AIR
SWPH -154
18.0
27.4
600
1/8
460/3
5,0
240
HP -107
COMMAND -AIR
SWPH -404
47.9
59.8
1600
1/3
460/3
w
384
HP -108
COMMAND -AIR
SWPH -204
24.4
35.3
800
1/6
460/3
252
HP -109
COMMAND -AIR
SWPH -204
24.4
35.3
850
1/6
460/3
252
HP -110
COMMAND -AIR
SWPH -204
24,4
35.3
810
1/6
460/3
252
HP -111
COMMAND -AIR
SWPH -107
4-
100
2117
27/1
240
11 6
HP -112
COMMAND -AIR
SWPH -154
18.0
27.4
600
1/8
460/3
5.0
240
HP -113
COMMAND -AIR
SWPH -404
47.9
59.8
1585
1/3
460/3
9.3
384
HP -113A
_
CLIMATEMASTER
GRH015AEC39RBS
14.1
16.8
500
1/6
277/1
6.3
147
HP -114
COMMAND -AIR
SWPH -504
59.3
96.6
1990
1/2
460/3
13.6
396
PR PERTY TAX \
262304 -9021
LEGAL DESCRIPTIO\
PARCEL 1 OF CITY OF TUKWILA REVISED SHORT PLAT
#77 -51 -55 AKA #3 -79 REC #7904180861 SD PLAT DAF ---
POR SE 1/4 OF NW 1/4 BEF AT MONUMENTAL INTSN OF
C /L'S OF SOUTHCENTER PARKWAY 57TH AVE S &STRANDER
BLVD S 164TH ST TH S 8 -45 -5 E 325.05 FT TH S
0-25-58 E 30 FT TO AN INTSN WITH S MGN SD STRANDER
BLVD & TPOB TH CONTG 0 -25 -58 E 200 FT TH S
89 -45 -58 E 350 FT TH S 0- 25--58 E 1093.20 FT TH N
89 -43 -19 W 626.31 FT TO E MGN SOUTHCENTER PARKWAY
TH N 0 -57 -48 W 1241.85 FT TO A PT OF CURVE TH NLY
& ELY ALG ARC OF CURVE TO RGT RAD 50 FT THRU C/A
91 -11 -50 79,53 FT TO S MGN STRANDER BLVD TH S
89 -45 -58 E 237.72 FT TO TPOB LESS POR OF SD PAR 1
FOR ST UNDER REC NO 8310250922
PROJECT LOCATIO\
16400 SOUTHCENTER PKWY
TUKWILA, WA 98188
PROJECT
0.
DESCRIPTION
INSTALLATION OF TWO (2) WATER SOURCE HEAT PUMPS W/
HOSE KITS. MODIFY EXISTING DUCTWORK, CONTROLS. MODIFY
EXISTING DUCTWORK. ADD NEW DIFFUSERS AS REQUIRED. ADD
TWO (2) NEW CONTROLS W /CONTROL WIRE.
v
ECH. CO\
TRACTOR
EMERALD AIRE, INC,
5108 D STREET NW
AUBURN, WA 98001
PROJECT MANAGER: RICK SIEMASHKEVICH
VOICE: (253) 872 -5665
FAX: ( 253) 872 -5797
GE \ERAL CO \TRACTOR
LEGACY PARTNERS
10655 NE 4TH ST, #812
BELLEVUE, WA 98002
R I T A MAESE-- NOAKER
VOICE; (206) 437 -0277
FAX: (206) 741-1678
VICINITY
V1 AP
SO
NO SCALE
C
N u Safi
R
DC.
W, S. E, C, NOTES
THERMOSTATS SHALL BE INTERLOCKED TO PREVENT SIMULTANEOUS
HEATING AND COOLING PER WSEC 1422,
ECONOMIZER CONTROLS SHALL BE CAPABLE OF EVALUATING
OUTDOOR AIR COOLING CAPACITY PER WSEC 1413,
GENERAL CONTRACTOR TO PROVIDE ACCESS TO FIRE AND /OR
COMBINATION FIRE /SMOKE DAMPERS.
INSULATE REFRIGERANT PIPING PER WSEC, TABLE 14 -6.
SEAL DUCTWORK PER WSEC 1414.1
INSULATE DUCTWORK PER WSEC TABLE 14 -5,
ECONOMIZERS SHALL MODULATE OUTSIDE AIR FROM MINIMUM TO
100% PER WSEC 1413. 1,
INDEX
m
,p
2r
MO TITLE SHEET
M1 GROUND FLOOR PLAN
HVAC DRAWING KEY
I K S U E GRD IDENTIFIER
0 SIDE WALL GRILL
SUPPLY GRILLE
® THERMAFUSER
® RETURN AIR GRILLE
❑ EXHAUST GRILLE
w
EXHAUST FAN
EQUIPMENT TAG
O T -STAT
- L/V WIRE
DUCT RUN
0 ELBOW
023 REDUCER
SIDE TAPS
' ' 90 ELBOW
�' W/ TURNING VANES
M O FLEXIBLE DUCT
MANUAL DAMPER
IAHu -11
k a
FIRE DAMPER
s ' '' SMOKE DAMPER
srn
ate
au]
a t
SMOKE /FIRE DAMPER
MBTORIZED DAMPER
BACKDRAFT DAMPER
VARIABLE VOLUME /TEMPERATURE
- ICE - VIEWED
CODE
APPROVED
APR 10 2008
FILE COPY
Permit Not
Plar review approval is subject to errors and omissions.
Approval of construe documents doeS not eUthodze
the violation of any adopted code or ordinance. Receipt
of approved eld Copy and is acimowledged:
No chap REVISIONS
changes sh all be made
of work without to the SGOpP
Tukwila Building v sion of
�
NOTE: Revisions will re 9 D ivision
end
may include quire a new Alen submittal t
additional plan reviaw f ees
Mog- Oct z
EiARATE PERMIT
REQUIRED FOR:
❑ Mechanical
Electrical
numbing
Or Gas Piping
City of Tukwila
BUILDING DIVISION
City of Tukwila
BUILDING DnfIVON
RECEIVE
MAR 2 7 2008
PERMIT CENTL
P: \Working Projects\Southcenter Bldg. (08- 0307) \CAD Drawings \M0 - TITLE SHEET.dwg
IP DATE 3/19/2008
❑ DESIGN DEVELOPMENT
DRAWING
COORDINATION
PERMIT
CONSTRUCTION
AS BUILT
COVER
SHEET
SCALE: AS NOTED
vo
08 -0307
C
3 7C1
M
N rn
v ,®
1V
C2 CO
rn
"Excellence'& Integrity"
5108 D ST. N.W.
AUBURN, WA 98001
(253) 872 -5665
TOLL FREE: (800) 291 -5191
FAX: (253) 872 -5797
CONT. # EMERAAI 055BL
PROJECT MANAGER: RICK S.
TITLE:
CLIENT: LEGACY PARTNERS
DRAWN BY: R.HILL
SOUTCE\TER BLDG.
16400 SOUTHCENTER PARKWAY
TUKWILA, WA 98188
❑ ❑ ❑ ❑ ❑
m
0)
3
c0 �? m ° a
Era
p �m
o
3
m
Z
-a
REVISIONS
DATE
DESCRIPTION