Permit M08-103 - BOEING - MILITARY FLIGHT CENTER
BOEING MILITARY FLIGHT CENTER 10002 E MARGINAL WY S M08-103 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: 0003400021 10002 EAST MARGINAL WY S TUKW Contact Person: Name: KEN RASMUSSEN Address: PO BOX 110 , AUMSVILLE OR Contractor: Name: JACOBS HEATING & AIR COND INC Address: 1421 S E HOLGATE BL , PORTLAND OR Contractor License No: JACOBHA192LA DESCRIPTION OF WORK: SUPPLY AND INSTALL (2) 22 TON COMPUTER ROOM HVAC UNITS Value of Mechanical: 103,000.00 Type of Fire Protection: Furnace: <100K BTU 0 >100K BTU 0 Floor Furnace 0 Suspended/Wall/Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System.... 0 Air Handling Unit <10,000 CFM 0 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 0 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial/Industrial 0 doc: IMC -10/06 Citylk Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us BOEING MILITARY FLIGHT CENTER 10002 EAST MARGINAL WY ST , TUKW1LA WA BOEING COMPANY THE PROPERTY TAX DEPT , PO BOX 3707 M/C 20 -00 MECHANICAL PERMIT Fees Collected: $1,229.38 International Mechanical Code Edition: 2006 EQUIPMENT TYPE AND OUANTITY * *continued on next page ** • Permit Number: Issue Date: Permit Expires On: Phone: Phone: 503 749 -4949 Phone: 503 234 -7331 Expiration Date: 03/14/2010 M08 -103 05/05/2008 11/01/2008 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 2 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 M08 - 103 Printed: 05 -05 -2008 I hereby certify that I have read and governing this work will be complie The grantin constructio Signature: Print Name: C3V\k A-Q 0 doc: IMC -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • Permit Number: M08 -103 Issue Date: 05/05/2008 Permit Expires On: 11/01/2008 Permit Center Authorized Signature: ! I Date: r oc ed this permit and know the same to be true and correct. All provisions of law and ordinances , whether specified herein or not. of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating the performance of work. I am authorized to sign and obtain this mechanical permit. Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M08 -103 Printed: 05 -05 -2008 Parcel No.: 0003400021 Address: Suite No: Tenant: . • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 10002 EAST MARGINAL WY S TUKW BOEING MILITARY FLIGHT CENTER 1: ** *BUILDING DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: ** *FIRE DEPARTMENT CONDITIONS * ** M08 -103 ISSUED 04/10/2008 05/05/2008 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 13: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 14: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 15: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) doc: Cond -10/06 M08 -103 Printed: 05 -05 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • 16: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 17: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 18: Local U.L. central station supervision is required. (City Ordinance #2051) 19: The installation of wiring and equipment shall be in accordance with N.F.P.A. 70, Article 760, Fire Protective Signaling Systems. (NFPA 72- 1.3.3) 20: These plans were reviewed by Inspector 515. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. 21: To schedule all construction fire - related inspections send an e-mail to fireinsprequest ©ci.tukwila.wa.us. Include your name, telephone number, permit number, project name and address and type of inspection requested. 22: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. doc: Cond -10/06 * *continued on next page ** M08 -103 Printed: 05-05 -2008 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. • . '�IVTAIVRallr Print Name: bn, t a • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us doc: Cond -10/06 M08 -103 • Date: J S ordinances governing or local laws regulating Printed: 05 -05 -2008 Parcel No.: 0003400021 Permit Number: M08 -103 Address: 10002 EAST MARGINAL WY S TUKW Status: APPROVED Suite No: Applied Date: 04/10/2008 Applicant: BOEING MILITARY FLIGHT CENTER Issue Date: Receipt No.: R08 -01485 Initials: JEM User ID: 1165 City of Tukwila Payee: MODERN BUILDING SYSTEMS, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 25570 979.38 ACCOUNT ITEM LIST: Description MECHANICAL - NONRES Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http://www.citukwila.wa.us RECEIPT Account Code Current Pmts 000.322.102.00.0 979.38 Total: $979.38 Payment Amount: $979.38 Payment Date: 05/05/2008 02:03 PM Balance: $0.00 1990 05/05 9711 TOTAL 979.38 doc: Receiot -06 Printed: 05 -05 -2008 Receipt No.: R08 - 01130 Initials: JEM User ID: 1165 Payee: CHARLES HELVIE • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.citukwila.wa.us Parcel No.: 0003400021 Permit Number: M08 -103 Address: 10002 EAST MARGINAL WY S TUKW Status: PENDING Suite No: Applied Date: 04/10/2008 Applicant: BOEING MILITARY FLIGHT CENTER Issue Date: TRANSACTION LIST: Type Method Descriptio Amount ACCOUNT ITEM LIST: Description r1nr.: Raraint -n8 Payment Cash 250.00 MECHANICAL - NONRES PLAN CHECK - NONRES RECEIPT Account Code Current Pmts 000.322.102.00.0 4.12 000/345.830 245.88 Total: $250.00 • Payment Amount: $250.00 Payment Date: 04/10/2008 12:26 PM Balance: $979.38 1021 04/10 2711 TOTAL 2 50.00 R PrintMrt. f14- 1(1 -200A Pro t: //06 //7/L/7 9 Cf Type of I pection: / /,c/4 / Address: �� ���� C�y / o f2- fi'�l� r "Ngiwu Daate / Special Instructions: 3 ) 3' b(� Date Wanted: 4 'v ,a' ►�i� Requester: Requester: Phone .4 — /7/ 5 INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 m4� /43 PERMIT NO. t IT (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: , A-t( Inspec 'r J� Date -�- / - vK 0 $58.00 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: 'Date: Project:R ,)e: n_ 1 f ° NV- Type gf�ns�ecctip�: j Address: Date Called: �~ Special Instructions: / Date Wanted: -.C-- i �. '' d ' p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION - 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (2 06)43 1 -3670 INSPECTION NO. Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspe or: Date: � .5; - L $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: Project: ( I Type of nsp n:/ Address: J f t ) r .. E A4 , .1 S • , A Date Called: Special Instructions: j Date Wanted. 5 — /L ' d( rr . p.m. Requester: Phone No: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspec 1 ' Date: , / + v8,- INSPECTION RECORD Retain a copy with permit GO PERMIT NO. $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: a o: = yw�: ..= wti= s.w.aG�G.sr _L .er:dJ�..�a. M • �. &.. .�_ : b...,..'rle�s. 9.1. :. _ .. _ +r,. - - _'a . • Ia. _. _ COMMENTS: Type of Inspection: riN4/ A i ( [ iL 1 (--4 l( 6) r I %-tk . IA l --" /t e 1: Cl ---1-- \ A `C ST l■ r: or 1l ;/‘ / cvr/ rAP.. & Requester: (.4JA`"7A (TOr iIA-4( AC IL" :/C LJP_ -e " :4 gf p f 0 r - 1 -- N) t Al ( I A c- (,L.1M' _ 1-i „t , ,/"kef e . S F 0" e2t4 A _ J(e- - {} (li A- (.-)1 ( -e M : p jj-T (r 604 ms f.r . „ n Project,: ' 50.../N6 INLET' / Type of Inspection: riN4/ Address: lbDf2 Q /71,94'6fn4 D to Called: / Special Instructions: Date Wanted: Requester: Ph o_ 5 3 o -6/5 f INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION Q- 6300 Southcenter Blvd., #1 00, Tukwila, WA 98188 (206)431 -3670 ❑ Approved per applicable codes. Inspect r: Date: $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: • INSPECTION RECORD Retain a copy with permit PERMIT NO. C orrections required prior to approval. Tenant Name: CITY OF TUKWIL' Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.citukwila.wa.us Site Address: , 01;Xp` Fs , ( t - J otA iSrv- i 14, FUe r C 6, ' Property Owners Naame: - Rsc ,, n 5 cio„ R1y Mailing Address: �i .Q. title In- 14 Mailing Address: 9.0 6tzi,e 110 E -Mail Address: \z6,,z Qas e tr S- m DO Building Pernll 7 /tit (0' Meehanical Permit No. Plumbing /Gas Permit No. Public Works Permit No Project No. f 0 F er) (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: OCO 3 4002 1 City Suite Number: Floor: New Tenant: fl .... Yes State Zip 0 CONTACT PERSON -- w ho do we ° ton ti ben your permit is ready to be issued' Name 7k.fi. : IBS Sy,. ,c. ��t.a. Sytwr- Day Telephone:St,A- ?gel 49 Amhs o y11, O!L 4n 314 - City State Zip Fax Number: 5 1 -1 S1) GENERAL CONTRACTOR INFORMATION - (Contractor Information for Mechanical (pg'4) for Plumbing and Gas Piping (pg 5) Company Name: 4701Qi i t o Mailing Address: ' .0 CSo>c \X p Contact Person: Le' f* ,5�- -- E -Mail Address: R.As e Contractor Registration Number: !'avO Contact Person: E -Mail Address: Company Name: M. Mali 0 Mailing Address: 9. D. g:X. l Contact Person: gas E -Mail Address: Q:\ApplicationsWorms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh tiP/Ni o i l City tnr+nry cal t`. City Day Telephone: State Zip Day Telephone: Sn3 -'7 _ 1qc 2f Fax Number: Sow -dint 0°ISII Expiration Date: t'v \ v 117 31 c -- 11p t of: ecord ARCHITECT OF REC ns must be Company Name: Mailing Address: City Day Telephone: Fax Number: State C State Zip NEER OF RECOF mped b ; inee'r o f Rect►r`dl Zip b 7 .49 -4 Fax Number: 1 - 49 5U Page 1 of 6 BUILDING PERMIT INFOIITION - 206-431-3670 of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Will there be new rack storage? E.... Yes Provide All Building Areas in Square Footage t Floo 2 71° Floor Addition to Existing Structure 3 Floor Floo th Basement p Accessory Structu Attached C Det ached Carpo Covered Deck Uncovere Deck Interior Remodel Type of struction per IBC Type of Occupancy per PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ Yes Q:\Applications\Forms- Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 bh Existing Building Valuation: $ ❑ .. No If yes, a separate permit and plan submittal will be required. Compact: Handicap: ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 - 1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 02/28/2008 07:23 P 02/27/2000 WED 17:21 MEcituff AL carrrRA.CToR FORMATION Company Mainz • Mailing Address: Contact Person: E-Mad Address: Contractor Registration Number: 5038139257 JACOBS HEATING FAX 503 • 4950 modern Building Syetem° Valuation of Mechanical work (contractor's bid price): Scope of Work (please provide detailed infbxmation): Usc: Residential: New _... ❑ Replacement .... f] Commercial: New .... Replacement ... _ ❑ : Furnace-100K BTU Floor Fumace S Mounted Ht e< Appliance Vent Repair or Addition to kieat/Refrig/Cooltng S stem Mr Handling Unit <10.000 CFM Electric.. .0 Gas ...❑ to S c Dud Ventilation System Hood said Duct Incinerator - Domestic Inciiteuatvr — Cotnmlitid QA4 Q udiss- 9a0s- Pem4/WptlmeioednG iumm 9.3000 Other: Indicate type o:Fmechanical wodc bang installed and the quantity below: F c :tc:• *.Z. Air Handling Unit >10,000 Fir+cDamp Furnace 100K BTU CFM B :..orator Cooler Ventilation Fan Connected Diffuser Thermostat Wood/Gas Stave EmergralcY Generator Other Methodical Equipment Seto zip City Day Telephone; -'�/1 1 2 3_ Fret Number: Expiration D :.. �/21 — IlaentO 0-3 IW /100,000 BTU 3.1 .5 HP/500 000 BTU 15 -30 M1,000,000 BTU 30 -50 BP /I,750,000 BTU 50+ HP/1,750,000 BTU PAGE 01/01 ®00` /0o_ Page dofG 97.zo Date Application Accepted: I, ( � b Date Application Expires: 1 f 1 [0 401 o Staff Initials: L PERMIT APPLICATION NOT)— Applicable to all permits in this `ap 'cation 30 4 Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OIVWYER OR AUTHORIZED AGENT: Signa Print Name: U.QVZ. e �J i Mailing Address: X SSt7 T'�._t S .t>J Q:\ Applications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Date: 4 11,1 7 i z* Day Telephone: D 5 3 - 71G3 - - g� 3 PiQ.E.I L4 I,001/4 C 1204.1 City State Zip Page 6 of 6 Fixture Type: Qty Fixture Type: Qty ' Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain Sinks Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and /or vent Additional medical gas inlets /outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and /or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets /outlets for specific gas PLUMBING AND GAS PIPINfl ERMIT INFORMATION - 206 - 43 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Plumbing work (contractor's bid price): $ Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): Building Use (per Int'1 Building Code): Occupancy (per Int'1 Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Q: \Applications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Page 5 of 6 7869 TRANI' FILE COPY Location Building owner Program user Company Comments Permit No.. By Dataset name Calculation time Play re' , 1 - -v- approval i3 sub ; nr n� rr' - TRACE® 700 version [n, r-.• - Location Latitude Longitude Time Zone Elevation Barometric pressure Air density Air specific heat Density- specific heat product Latent heat factor Enthalpy factor Summer design dry bulb Summer design wet bulb Winter design dry bulb Summer clearness number Winter clearness number Summer ground reflectance Winter ground reflectance Carbon Dioxide Level Design simulation period Cooling Toad methodology Heating load methodology Seattle Area Boeing PNK M FIA F -22 Facility MF1A Inc. Z:\TRACE7001Projectsljacob heating17869_F -22 Secure Fac 02:36 PM on 03/21/2008 6.1.2 Seattle, Washington 47.0 deg 122.0 deg 8 386 ft 29.5 in. Hg 0.0749 0.2444 1.0988 4,836.9 4.4953 80 64 26 0.95 0.95 0.20 0.20 400 Ib /cu ft Btullb• °F Btu /h•cfm• °F Btu•min /h•cu ft ib•min /hr•cu ft °F °F °F ppm January - December CLTD -CLF (ASHRAE TFMI UATD SEWED FOR CODE COMPLIANCE APPROVED MAY - � 2008 CITY OF TUKWHJ APR 10 2008 PERMIT CENTER tem T.... n. AAA 10 .M-u. hem Trnr Left Side System Checksums Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass Cond Wall Cond Partition Exposed Floor Infiltration Sub Total =_> Internal Loads Lights People Misc Sub Total =_> Ceiling Load Ventilation Load Ad) Air Trans Heat Dehumid. Ov Sizing Ov /Undr Sizing Exhaust Heat Sup. Fan Heat Ret. Fan Heat Duct Heat Pkup Reheat at Design Grand Total =_> COOLING COIL PEAK Peaked at Time: Mo /Hr: 7 / 16 Outside Air: OADB/WB/HR: 79 / 63 / 62 Space Sens. + Lat. Btu /h 0 0 0 0 0 684 0 -437 0 Plenum Sens. + Lat Btu /h 2,889 0 0 86 770 7 0 0 -437 -4 0 0 247 2,975 3,222 31 4,282 1,071 1,100 0 0 5,382 1,071 4,046 -4,046 0 0 0 9,675 Net Percent Total Of Total Btu /h ( %) 0 0 0 0 0 0 2,889 28 D 0 0 0 5,353 52 1,100 11 0 0 6,453 63 0 0 0 370 4 0 0 0 0 0 0 0 0 0 246 2 0 0 0 0 0 0 0 0 0 10,291 100.00 CLG SPACE PEAK Mo /Hr: Sum of OADB: Peaks Space Percent Sensible Of Total Btu /h ( %) 0 0 0 0 0 684 0 -437 0 247 0 0 0 0 0 7 0 -5 0 3 Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass Cond Wall Cond Partition Exposed Floor Infiltration Sub Total = => Internal Loads 4,282 47 Lights 550 6 People 0 0 Misc 4,832 53 Sub Total =_> 4,046 44 Ceiling Load 0 0 Ventilation Load 0 0 Adj Air Trans Heat Ov /Undr Sizing 0 0 Exhaust Heat OA Preheat Diff. RA Preheat Diff. Additional Reheat 9,125 100.00 Grand Total =_> HEATING COIL PEAK Mo /Hr: Heating Design OADB: 26 Space Peak Space Sens Btu/h Coil Peak Percent Tot Sens Of Total Btu/ (%) 0 0 0 -2,14 0 0 -1,750 -2,18 0 -5,349 -5,34 0 -7,100 -9,682 0 0 0 0 -2,582 0 0 0 -9,682 0.00 0.00 18.48 0.00 0.00 18.82 0.00 46.05 0.00 83.35 0 0 0 0 0.00 0 0.00 -1,934 16.65 0 0 0 0.00 0 0.00 0 0.00 0 0.00 0 0.00 0.00 0.00 0.00 - 11,616 100.00 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB /HR ton MBh Main Cig 0.9 10.3 Aux Cig 0.0 0.0 Opt Vent 0.0 0.0 Total 0.9 10.3 MBh cfm °F °F gr /Ib Leave DB gr/lb 9.6 415.2 75.4 60.4 55.8 54.5 51.6 53.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Project Name: 7869 Dataset Name: Z:ITRACE7001Projectsljacob heating \78692-22 Secure Facility17869 _F- 22_Secure_Facility.trc Floor Part ExFIr Roof Wall AREAS Gross Total Glass ft ( %) 1,307 0 1,307 1,307 0 0 1,087 0 0 Single Zone TEM PERATURES Cooling Heating SADB 55.0 91.2 Plenum 84.8 63.8 Return 75.0 70.0 Ret/OA 75.4 65.8 Fn MtrTD 0.1 0.0 Fn BidTD 0.1 0.0 Fn Frict 0.4 0.0 Vent Infil Supply MinStop/Rh Return Exhaust Rm Exh Auxiliary AIRFLOWS Cooling 40 0 415 0 415 40 0 0 Heating 40 0 415 0 415 40 0 0 ENGINEERING CKS % OA cfm /ft' cfm /ton 484.17 ft' /ton 1,524.01 Btulhr•ft No. People Cooling Heating 9.6 9.6 0,32 0.32 7.87 -8.89 2 HEATING COIL SELECTION CapacityColl Airflow Ent Lvg MBh cfm °F °F Main Htg -11.6 415.2 65.8 91.2 Aux Htg 0.0 0 0 0 Preheat 0.0 0 0 0 Humidif 0.0 0 0.0 0.0 Opt Vent 0.0 0 0.0 0.0 Total -11.6 TRACE® 700 v6.1.2 calculated at 02:36 PM on 03/21/2008 Alternative - 1 System Checksums Report Page 1 of 2 Right Side Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass Cond Wall Cond Partition Exposed Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load AdJ Air Trans Heat Dehumld. Ov Sizing Ov /Undr Sizing Exhaust Heat Sup. Fan Heat Ret. Fan Heat Duct Heat Pkup Reheat at Design Grand Total = => COOLING COIL PEAK Peaked at Time: Outside Air: Space Sens. + Lat. Btu /h o 0 0 0 0 0 0 0 0 0 0 3,057 3,057 16 0 0 0 0 0 0 0 0 0 0 0 824 127 951 5 873 0 0 0 0 -783 -783 -4 -605 0 0 0 0 41 3,184 3,225 17 268 4,227 1,057 5,283 28 4,227 7,650 7,650 41 4,250 0 0 0 0 0 11,877 1,057 12,933 69 8,477 4,240 -4,240 0 0 4,250 0 0 2,175 12 0 O 0 0 0 0 0 O 0 0 0 0 0 0 350 2 0 0 0 0 16,159 Mo /Hr: 7 / 14 OADB/WB/HR: 79 / 64 / 67 Plenum Sens. + Lat Btu /h Net Percent Space Total Of Total Sensible Btu /h ( %) Btu/h 0 0 0 0 0 18,684 100.00 System Checksums CLG SPACE PEAK Mo /Hr. Sum of OADB: Peaks Percent Of Total ( %) 2 33 33 0 65 12,994 100.00 Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass Cond Wail Cond Partition Exposed Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total = => 33 Ceiling Load 0 Ventilation Load 0 Ad) Air Trans Heat Ov/Undr Sizing 0 Exhaust Heat OA Preheat DIff. RA Preheat Diff. Additional Reheat Grand Total ==> Main Clg Aux Clg Opt Vent Total COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR ton MBh MBh cfm °F °F gr /Ib 1.6 18.7 14.8 591.3 77.5 63.4 66.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1.6 18.7 Leave DB/WB/HR °F °F gr /Ib 54.5 52.7 57.2 0.0 0.0 0.0 0.0 0.0 0.0 Project Name: 7869 Dataset Name: Z:ITRACE7001Projectsljacob heating17869_F -22 Secure Facility17869 _F- 22_Secure_Facility.trc HEATING COIL PEAK Mo /Hr: Heating Design OADB: 26 Space Peak Space Sens Btu /h 0 0 0 0 0 -1,645 0 -5,280 0 -6,925 -9,456 Floor Part ExFIr Roof Wall AREAS Gross Total Glass ft2 ( %) 1,290 0 1,290 1,290 0 0 1,057 0 0 Coil Peak Percent Tot Sens Of Total Btu /h ( %) 0 0.00 0 0.00 -2,121 8.19 0 0.00 0 0.00 -2,055 7.94 0 0.00 -5,280 20.39 0 0.00 -9,456 36.52 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 -2,531 0 0.00 0 - 16,438 63.48 0 0 0 0 0 0.00 0 0.00 0 0.00 O 0.00 O 0.00 - 25,894 100.00 Single Zone TEMPERATURES Cooling Heating SADB 55.0 84.6 Plenum 85.4 63.8 Return 75.0 70.0 Ret/OA 77.5 44.7 Fn MtrTD 0.1 0.0 Fn BIdTD 0.1 0.0 Fn Frict 0.4 0.0 Vent Infil Supply MinStop/Rh Return Exhaust Rm Exh Auxiliary AIRFLOWS Cooling 340 0 591 0 591 340 0 0 Heating 340 0 591 0 591 340 0 0 ENGINEERING CKS Cooling Heating % OA 57.5 57.5 cfm/ft 0.46 0.46 cfm /ton 379.76 ft /ton 828.53 Btu /hr-ft 14.48 -20.07 No. People 17 HEATING COIL SELECTION Capacity Coil Airflow Ent MBh cfm °F Lvg °F Main Htg -25.9 591.3 44.7 84.6 Aux Htg 0.0 0 0 0 Preheat -6.3 591 45 54 Humidif 0.0 0 0.0 0.0 Opt Vent 0.0 0 0.0 0.0 Total - 25.9 TRACE® 700 v6.1.2 calculated at 02:36 PM on 03/21/2008 Alternative - 1 System Checksums Report Page 2 of 2 System Zone Room ** AltirnatketWoir - Leftside Zone - 001 Zone - 001 Left Side Left Side Rightside Zone - 002 Zone - 002 Right Side Right Side Load / Airflow Summary By MFIA Inc. Floor Area People ft' Coil Cooling Sensible BtWh Coil Space Cooling Design Air Total Max SA Changes Btu/h cfm achlhr 4.74 Rm Peak 1,307 2.0 Zn Peak 1,307 2.0 Zn Block 1,307 2.0 Sys Peak 1,307 2.0 Sys Block 1,307 2.0 Rm Peak 1,290 17.0 Zn Peak 1,290 17.0 Zn Block 1,290 17.0 Sys Peak 1,290 17.0 Sys Block 1,290 17.0 VAV Main Coll Heating Minimum Heating Fan Percent ASHRAE SA Sensible Max SA OA Std 62 cfm Btulh cfm CIg Htg OA Fraction 9,565 10,291 415 2.46 0 -11,616 415 9.6 9.6 9,565 10,291 415 -11,616 9,565 10,291 415 -11,616 9,665 10,291 415 -11,616 9,565 10,291 415 -11,616 14,753 18,684 591 3.55 0 -25,894 14,753 18,684 591 -25,894 14,753 18,684 591 -25,894 14,753 18,684 591 -25,894 14,753 18,684 691 -25,894 415 9.6 415 9.6 415 9.6 415 9.6 9.6 9.6 9.6 9.6 591 57.5 57.5 591 57.5 57.5 591 57.5 57.5 591 57,5 57.5 591 57.5 57.5 ** This report does not display heating only systems. Project Name: 7869 TRACE® 700 v6.1.2 calculated at 02:36 PM on 03/21/2008 Dataset Name: ZATRACE7001Projectstjacob heating17869_F-22 Secure Load/Airflow Summary Report Page 1 of 1 Envelope Requirements (enter values as applicable) Project Address Minimum Insulation R- values Roofs Over Attic _ 2663.0 X 1 00 = Concrete/Masonry Option All Other Roofs 0 yes Check here if using semi - heated path and if project meets all requirements for semi - heated spaces Semi- Heated Path no as defined in section 1310. Requires other fuel heating and qualifying thermostat. Only wall insulation requirement is reduced (2006 change). Only available in prescriptive path. 2 5 . 0 Opaque Walls 19.0 Below Grade Walls Tukwila, WA 98168 -1802 Floors Over Unconditioned Space 19.0 Slabs -on -Grade Modern Building Systems, Inc. 2008 Radiant Floors Applicant Address: 9493 Porter Road Aumsville, Maximum U- factors Opaque Doors t, _ el 0.600 Vertical Glazing 0.360 Overhead Glazing Maximum SHGC (or SC) Vertical /Overhead Glazing I 0.350 Project Info Project Address Boeing Total Glazing Area Electronic version: these values are automatically taken from ENV -UA -1. (rough opening) Gross Exterior (vertical & overhd) divided by Wall Area times 100 equals V. Glazing _ 2663.0 X 1 00 = Concrete/Masonry Option Date 4/8/2008 0 yes Check here if using semi - heated path and if project meets all requirements for semi - heated spaces Semi- Heated Path no as defined in section 1310. Requires other fuel heating and qualifying thermostat. Only wall insulation requirement is reduced (2006 change). Only available in prescriptive path. 10002 East Marginal Way South For Building Department Use ���� COPY -_. Ow A a _ Tukwila, WA 98168 -1802 Applicant Name: Modern Building Systems, Inc. 2008 Applicant Address: 9493 Porter Road Aumsville, OR 97325 t, _ el Applicant Phone: 503- 749 -4949 a;_ NM Space Heat Type 0 Electric resistance 0 All other (see over for definitions) Glazing Area Calculation Note: Below grade walls may be included in the Gross Exterior Wall Area if they are insulated to the level required for opaque walls. Total Glazing Area Electronic version: these values are automatically taken from ENV -UA -1. (rough opening) Gross Exterior (vertical & overhd) divided by Wall Area times 100 equals V. Glazing _ 2663.0 X 1 00 = Concrete/Masonry Option O yes Check here if using this option and if project meets all requirements for the Concrete/Masonry Option. See Decision Flowchart (over) for qualifications. Enter requirements for each qualifying ® no assembly below. 0 yes Check here if using semi - heated path and if project meets all requirements for semi - heated spaces Semi- Heated Path no as defined in section 1310. Requires other fuel heating and qualifying thermostat. Only wall insulation requirement is reduced (2006 change). Only available in prescriptive path. Opaque Concrete /Masonry Wall Requirements Wall Maximum U- factor is 0.15 (R5.7 continuous ins) CMU block walls with insulated cores comply If project qualifies for Concrete /Masonry Option, list walls with HC >_ 9.0 Btu /ft'-°F below (other walls must meet Opaque Wall requirements). Use descriptions and values from Table 10 -9 in the Code. r;,h:t . I ue & position) U- factor A/ -1 2008 „ t, _ el Mlle a;_ l . kJ _ rtITy F — AP? 10 2008 EnvelopeF`Summa 1imate'Zone ;,� 2006 Washington State Nonresidential Energy Code Compliance Forms Project Description El New Building ❑ Addition ❑ Alteration ❑ Change of Use - e I I u l 1. Assemblies with metal framing must comply with overall U- factors Notes: 2006 Washington State Nonresidential Energy Code Compliance Form RE COD i�. Revised July 2007 Compliance Option Prescriptive ❑ Component Performance / (See Decision Flowchart (over) for qualifications) .f ...._` -. _ Seattle Systems Analysis PERMIT CENTER Envelope Summary (back) Climate Zone 1 ENV -SUM 2006 Washington State Nonresidential Energy Code Compliance Forms Decision Flowchart for Prescriptive Option Use this flowchart to determine if project qualifies for the optional Prescriptive Option. If not, either the Component Performance or Systems Analysis Options must be used. 1302 Space Heat Type: For the purpose of determining building envelope requirements, the following two categories comprise all space heating types: Other: All other space heating systems including gas, solid fuel, oil, and propane space heating systems and those systems listed in the exception to electric resistance (continued at right) 41--N Below Grd Wall (ext) R -10 Below Grd Wall (oth) R -19 Roof Over Attic R -30 All Other Roof Raised Floor Slab-On -Grade Radiant Floor R -10 Opaque Door 0.6 All Insulation Installed? Yes AG Mass Wall Insulation Req Mass Wall U0.15/R5.7ci CMU Block Ins. Cores Wood Frame R19 Metal Framed R19 2006 Washington State Nonresidential Energy Code Compliance Form (es Glazing Glazing Cnteria Met? Vert OH Ar e UPI 0 -3 0.0-30, 0.5 0.70 0.4 30-45% 0.45 0.60 40 >45% Not Allowed No Yes START Component Performance Systems Analysis, or EnvStd Required Electric Resistance: Space heating systems which use electric resistance elements as the primary heating system including baseboard, radiant, and forced air units where the total electric resistance heat capacity exceeds 1.0 Wift of the gross conditioned Floor area. Exception: Heat pumps and terminal electnc resistance heating in variable air volume dtstnbution systems. G Wall R1 wood, or 0.062 met All Insulation Installed? Below Grd Wall (ext) Below Grd Wall (oth) Roof Over Attic All Other Roof Raised Floor Slab -On -Grade Radiant Floor O.a•ue Door Wood Metal R -10 R -10 R-19 U -0.062 R-38 U -0.031 R -30 U -0.034 R -30 U -0.029 R -10 R -10 R -10 R -10 U -0.60 U -0.60 Yes Glazing Criteria Met? Pripe Yes tiv Path Allowed Glazing Vert OH Area % UVat UVaI SHGC 0-30% 0.40 0.60 0.40 >30 Not Allowed • AG Mass Wall Insulation Req Mass Wall U0.15/R5.7ci CMU Block Ins. Cores Wood Frame R19 Metal Framed U0.062 Concrete/Masonry Option* Assembly Description Wall Heat Capacity (HC) Assy.Tag HC ** Totals Area (sf) Area weighted HC: divide total of (HC x area) by Total Area HC x Area Revised July 2007 No-- No-► *If the area weighted heat capacity (HC) of the total above grade wall is a minimum of 9.0, the Concrete Masonry Option may be used. * *For framed walls, assume HC =1.0 unless calculations are provided; for all other walls, use Section 1009. Building Permit Plans Checklist = :, 2006 Washington State Nonresidential Energy Code Compliance Forms . ENV - . CHK Revised July 2007 Project Address Boeing Date 4/8/2008 The following information is necessary to check a building permit application for compliance with the building envelope requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes GENERAL REQUIREMENTS (Sections 1301 -1314) 1301 Scope Unconditioned spaces identified on plans if allowed yea 1302 Space heat type: Other If "Other", indicate on plans that electric resistance heat is not allowed M10 n.a. 1310.2 Semi - heated spaces Semi - heated spaces identified on plans if allowed 1311 Insulation yea 1311.1 Insul. installation Indicate densities and clearances A10 yes 1311.2 Roof /ceiling insul. Indicate R -value on roof sections for attics and other roofs; Indicate clearances for attic insulation; Indicate baffles if eave vents installed; Indicate face stapling of faced batts A10, A200 yes 1311.3 Wall insulation Indicate R -value on wall sections; Indicate face stapling of faced batts; Indicate above grade exterior insulation is protected; Indicate loose -fill core insulation for masonry walls as necess; Indicate heat capacity of masonry walls if masonry option is used F73; A10, A200 yes 1311.4 Floor insulation Indicate R -value on floor sections: Indicate substantial contact with surface; Indicate supports not more than 24" o.c.; Indicate that insulation does not block airflow through foundation vents A10, A200 n.a. 1311.5 Slab-on-grade floor Indicate R -value on wall section or foundation detail; Indicate slab insulation extends down vertically 24" from top; Indicate above grade exterior insulation is protected n.a. 1311.6 Radiant floor Indicate R -value on wall section or foundation detail; Indicate slab insulation extends down vertically 36" from the top; Indicate above grade exterior insulation is protected; Indicate insulation also under entire slab where req'd. by Official yes 1312 Glazing and doors Provide calculation of glazing area (including both vertical vertical and overhead) as percent of gross wall area A10 yes 1312.1 U- factors Indicate glazing and door U- factors on glazing and door schedule (provide area - weighted calculations as necessary); Indicate if values are NFRC or default, if values are default then specify frame type, glazing layers, gapwidth, low-e coatings, gas fillings A10 yes 1312.2 SHGC & SC Indicate glazing solar heat gain coefficient or shading coefficient on glazing schedule (provide area- weighted calculations as necessary) A10 1313 Moisture control yes 1313.1 Vapor retarders Indicate vapor retarders on warm side A10 yea 1313.2 Roof /ceiling vap.ret. Indicate vapor retarder on roof section; Indicate vap. retard. with sealed seams for non -wood strut. A10 yes 1313.3 Wall vapor retarder Indicate vapor retarder on wall section A10 yes 1313.4 Floor vapor retarder Indicate vapor retarder on floor section A10 n.a. 1313.5 Crawl space vap. ret. Indicate six mil black polyethylene overlapped 12" on ground 1314 Air leakage yea yes 1314.1 Bldg. envel. sealing Indicate sealing, caulking, gasketing, and weatherstripping A10 1314.2 Glazing/door sealing Indicate weatherstripping A10 yes 1314.3 Assemb. as ducts Indicate sealing, caulking and gasketing 1410 n.a. 1314.4 Recessed Lighting Fixture Indicate IC rating, ASTM E283 certification, and gasketing or caulking to ceiling PRESCRIPTIVE /COMPONENT PERFORMANCE (Sections 1320 -23 or 1330 -34) yes Envelope Sum. Form Completed and attached. Provide component performance worksheet if necessary If "no" is shown for any question, provide explanation: 2006 Washington State Nonresidential Energy Code Compliance Form Cooling Equipment Schedule Equip. ID Brand Name' Model No.' Capacity Btu /h Total CFM OSA CFM or Econo? SEER or EER IPLV Location A Bard WH421 -C 41500 1400 Econo 10.00 Ext. Wall B Bard WH421-C 41500 1400 Econo 10.00 Ext. Wall Fan Equipment Schedule Equip. ID Brand Name' Model No.' CFM SP' HP /BHP Flow Control Location of Service Efficiency A Bard WH421 41000 1400 Econo Modern Building Systems, Inc. 6.800 B Bard WH421 41000 1400 Econo 6.800 Heating Equipment Schedule Equip. ID Brand Name' Model No.' Capacity Btu /h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency A Bard WH421 41000 1400 Econo Modern Building Systems, Inc. 6.800 B Bard WH421 41000 1400 Econo 6.800 Project Info Project Address Boeing Date 4/8/2008 10002 East Marginal Way South For Building Dept. Use Tukwila, WA 98168 -1802 Applicant Name: Modern Building Systems, Inc. Applicant Address: 9493 Porter Road Aumsville, OR 97325 Applicant Phone: 503- 749 -4949 Mechanical Summary 2006 Washington State Nonresidential Energy Code Compliance Forms Project Description Briefly describe mechanical system type and features. 0 Includes Plans 2006 Washington State Nonresidential Energy Code Compliance Form (2) 3.5 Ton Wall -Hung Heat Pumps with 9kw Heat Strips and Economizers Drawings must contain notes requireing compliance with commissioning requirements - Section 1416 'If available. 2 As tested according to Table 14-1A through 14-1G. 3 If required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). Revised July 2007 Compliance Option Qi Simple System Q Complex System Q Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling or Cooling Only: ❑ Constant vol? ❑ Split system? ❑ Air cooled? ❑ Packaged sys? ❑ <20,000 Btuh? ❑ Economizer included? If Heating Only: ❑ <5000 cfm? ❑ <70% outside air? Mechanical Summary (back Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. otal Ca . wo economize <240,000 Btuh or 10 %? 2006 Washington State Nonresidential Energy Code Compliance Form Reference Section 1421 mple System Allowed (section 1420 Reference "\ Section 1423 Use Complex Systems (section 1430) Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. Mechanical Permit Plans ,Checklist �� " -` ��' ��� MECH -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address Boeing Date 4/8/2008 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance yes 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule M10 yes 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency Cuts n.a. 1411.1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket loss 1412 HVAC controls yes 1412.1 Temperature zones Indicate locations on plans M10 yes 1412.2 Deadband control Indicate 5 degree deadband minimum cuts n.a. 1412.3 Humidity control Indicate humidistat yes 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types cuts yes 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage cuts n.a. 1412.4.2 Optimum Start Indicate optimum start controls yes 1412.5 Heat pump control Indicate microprocessor on thermostat schedule Cuts n.a. 1412.6 Combustion htg. Indicate modulating or staged control yes 1412.7 Balancing Indicate balancing features on plans M10 1412.8 Ventilation Control Indicate demand control ventilation for high- occupancy areas n.a. 1422 Thermostat interlock Indicate thermostat interlock on plans yes 1423 Economizers Equipment schedule M10 1413 Air economizers yes 1413.1 Air Econo Operation Indicate 100% capability on schedule Cuts n.a. 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb n.a. 1413.2 Water Econo Doc Indicate clg load & water econoe & clg tower performance n.a. 1413.3 Integrated operation Indicate capability for partial cooling n.a. 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems yes 1414.1 Duct sealing Indicate sealing necessary M10 yes 1414.2 Duct insulation Indicate R -value of insulation on duct M10 n.a. 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Completion Requirements yes 1416.2.1 Commissioning Provide commissioning plan M10 n.a. 1416.2.2 -3 Sys.Bal & Func.Test Indicate air and water system balancing & functional testing yes 1416.2.4 Commissioning Indicate O &M manuals, record drawings, staff training M10 yes 1416.2.5 Comm. Report Indicate requirements for prelim. & final commissioning report M10 n.a. 1434 Separate air sys. Indicate separate systems on plans yes Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. n.a. 1441 Elec. water heater Indicate R -10 insulation under tank n.a. 1442 Shut -off controls Indicate automatic shut -off n.a. 1443 Pipe Insulation Indicate R -value of insulation on piping n.a. 1452 Heat Pump COP Indicate minimum COP of 4.0 n.a. 1452 Heater Efficiency Indicate pool heater efficiency n.a. 1453 Pool heater controls Indicate switch and 65 degree control n.a. 1454 Pool covers Indicate vapor retardant cover n.a. 1454 Pools 90+ degrees Indicate R -12 pool cover 2006 Washington State Nonresidential Energy Code Compliance Form no is circ for any question, provide explanation: Project Info Project Address Boeing Date 4/8/2008 10002 East Marginal Way South For Building Department Use Tukwila, WA 98168 -1802 Applicant Name: Modern Building Systems, Inc. ApplicantAddress: 9493 Porter Road Aumsville, OR 97325 Applicant Phone: 503- 749 -4949 Project Description ❑ Plans Included requirements. ./ New Building ❑ Addition ❑ Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option Q Prescriptive 0 Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Location (floor /room no.) Occupancy Description Allowed Watts per ft2 ** Area in ft Allowed x Area Whole Building Office 1. 00 2644.0 2644.0 ** From Table 15-1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 2644.0 Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Office 2 -Tube T8 32W Fluorescent Lay -in with Elect. Ballast 32 58.0 1856.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 1856.0 Interior Lighting Summa 2006 Washington State Nonresidential Energy Code Compliance Forms Maximum Allowed Lighting Wattage Proposed Lighting Wattage 2006 Washington State Nonresidential Energy Code Compliance Form Revised July 2007 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. Use' LPA` (W /sf) Use' LPA` (W /sf) Automotive facility 0.9 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches) 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire station? 1.0 Cafeterias, fast food establishments', restaurants /bars 1.3 Post office 1.1 Dormitory 1.0 Retail retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia assembly spaces" 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel /motel 1.0 Warehouses ", storage areas 0.5 Hotel banquet/conference/exhibition hall 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified 'laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries' 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies' (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Prescriptive Spaces Occupancy: 0 Warehouses, storage areas or aircraft storage hangers gtOther Qualification Checklist Chklist Note: If occupancy type is "Other" and fixture Lighting Fixtures: o ❑ Check if 95 /o or more of fixtures comply with 1,2 or 3 and rest are ballasted. answer is checked, the number of fixtures in (Section 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector the space is not limited by Code. Clearly 1521) or louvers, c) 5 -60 watt T -1, T - 2, T - 4, T - 5, T - 8 lamps, and d) hard - wired elec- indicate these spaces on plans. If not tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. qualified. do LPA Calculations. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. Interior Lighting Summary: (back) 2006 Washington State Nonresidential Energy Code Compliance Forms 2006 Washington State Nonresidential Energy Code Compliance Form Revised July 2007 TABLE 15 -1 Unit Lighting Power Allowance (LPA Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. Project Info Proj Addres. Boeing Date 4/8/2008 10002 East Marginal Way South For Building Department Use Tukwila, WA 98168 -1802 Name: Modern Building Systems, Inc. Appl. Name 9493 Porter Road Aumsville, OR 97325 Appl. Phone 503- 749 -4949 Project Description 20 W /LF of door widt New ❑ Addition ❑ Alteration . Plans Included Indicate controls (Sections 1513) including commissioning requirements on plans. Compliance Option Q Lighting Power Allowance 0 Systems Analysis Building Grounds (luminaires > 100 Watts) ❑ Efficacy > 60 lumens/W ❑ Controlled by motion Sensor ❑ Exemption (list) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Tradable Locations Description Allowed Watts per ft or per If Area (ft perimeter (If) or # of items Allowed Watts x ft (or x If) Main Entry 30 W /LF of door widt 3.0 90. 0 Other Entries 20 W /LF of door widt 6.0 12 0. 0 I Non - Tradable Locations Description Allowed Watts per ft or per If Area (ft perimeter (If) or # of items Allowed Watts x ft (or x If) Exits 26W WP Compact Fluorescent with Photocell 2 26.0 52.0 Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Exits 26W WP Compact Fluorescent with Photocell 2 26.0 52.0 Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Exits 26W WP Compact Fluorescent with Photocell 2 26.0 52.0 Exterior Lighting Summary 2006 Washington State Nonresidential Energy Code Compliance Forms Tradable Maximum Allowed LiQhtin Wattage Tradable Proposed Lighting Wattage Total Proposed Watts may not exceed Total Allowed Watts for Exterior Non - Tradable Maximum Allowed Lighting Wattage Non - Tradable Proposed Lighting Wattage 2006 Washington State Nonresidential Energy Code Compliance Form Proposed Watts may not exceed Allowed Watts for Category Total Allowed Watts Revised July 2007 210.0 Use mfgr listed maximum input wattage. For fixtures with hard -w'red ballasts only, the default table in the NREC Technical Reference Manual may also be used. Total Proposed Watts 52.0 Lighting ; °° Motor; and TransformerP;ermit 2006 Washington State Nonresidential Energy Code Compliance Forms Plans:Checklist LTG -CHK Revised July 2007 Project Address Boeing Date 4/8/2008 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Ene gy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control /access Schedule with type, indicate locations Elo yes 1513.2 Area controls Maximum limit per switch El° n.a. 1513.3 Daylight zone control Schedule with type and features, indicate locations n.a. vertical glazing Indicate vertical glazing on plans n.a. overhead glazing Indicate overhead glazing on plans n.a. 1513.4 Display /exhib /special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features, indicate location n.a. (a) timer w /backup Indicate location yes (b) photocell. Indicate location Eio 1513.6 Inter. auto shut -off Indicate location n.a. 1513.6.1 (a) occup. sensors Schedule with type and locations n.a. 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans yes 1513.7 Commissioning Indicate requirements for lighting controls commissioning El0 EXIT SIGNS (Section 1514) n.a. I 1514 'Max. watts 'Indicate watts for each exit sign 1 LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture yes 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) n.a. I 1511 IElec motor efficiency IMECH -MOT or Equipment Schedule with hp, rpm, efficiency' TRANSFORMERS (Section 1540) n.a. I 1540 'Transformers 'Indicate size and efficiency I 1 2006 Washington State Nonresidential Energy Code Compliance Form If "no" is circled for any question, provide explanation: ACTIVITY NUMBER: M08 - 103 DATE: 04 - - PROJECT NAME: BOEING MILITARY FLIGHT CENTER SITE ADDRESS: 10002 EAST MARGINAL WY S X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: 4- uilg ingD'vision Public Works Complete DETERMIN OF COMPLETENESS: (Tues., Thurs.) Comments: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 PLAN REVIEW /ROUTING SLIP • PERMIT COORD COPY 516 Mc- Fire Prevention Structural Incomplete n TUES/THURS ROUT NG: Please Route Structural Review Required REVIEWER'S INITIALS: DUE DATE: 04-1508 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DATE: DUE DATE: 05-13-08 Approved n Approved with Conditions RA Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Planning Division Permit Coordinator n n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License JACOBHA 192LA Licensee Name JACOBS HEATING & AIR COND INC Licensee Type CONSTRUCTION CONTRACTOR UBI 409006673 Ind. Ins. Account Id Business Type CORPORATION Address 1 1421 S E HOLGATE BLVD Address 2 City PORTLAND County OUT OF STATE State OR Zip 97202 Phone 5032347331 Status ACTIVE Specialty 1 HTGNENT /AIR CONDITIONING Specialty 2 UNUSED Effective Date 6/1/1981 Expiration Date 3/14/2010 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date JACOBS, BRENT D 01/01/1980 JACOBS, GREGORY J 01/01/1980 Look Up a Contractor, Electrn or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. • Bond Information Bond #4 Bond Company Name TRAVELERS CAS & STY CO OF AMER Bond Account Number 104061592 Effective Date 07/07/2003 Expiration Date Until Cancelled Cancel Date Impaired Date Bond Amount $6,000.00 Received Date 07/14/2003 Page 1 of 3 https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= JACOBHA192LA 05/05/2008 SYM AREA VAP FLIGHT MUSEUM OXBOW PARKING LOT NO SCALE CODE SU V VARY LAND USE CODE BUILDING CODES OCCUPANCY GROUP CONSTRUCTION TYPE FLOOR AREAS: BUILDING FOOTPRINT BUILDING GROSS FIRST FLOOR BUILDING HEIGHT STORIES OCCUPANT LOAD: HANDICAPPED REQUIREMENTS FIRE PROTECTION: SEISMIC CITY OF TUKWILA 2006 I.B.C. CODES AND THE WAC 51 -20 AS ADAPTED OR AMENDED BY LOCAL ORDINANCES, AND COMPLIANCE WITH CITY OF TUKWILA ZONING. GROUP B TYPE II, NON- COMBUSTBLE 2706 2706 2706 13' -8" 1 27 BARRIER FREE SPRINKLER 5 = 1.50 REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE BOE /NG r� SEPARATE PERMIT REQUIRED FOR ❑ gElectrical Mechanic ai gliflumbing r Gas Piping City of Tukwila niNG DIVISION E PIRES1 7/2/08 AC E=PTABILITY HIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. 7 DATE 6 4 DRAWN L. HINES CHECKED ENGINEER K. RASMUSSEN CHECKED APPROVED APPROVED 0 SCALE: 1" = 20' DATE 02.18.05 REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. - LIEBERT CONDE4SERS SEE SLEET M11 TITLE 60 4 '0 SPRINKLER PIPE STUBBED OUT CF GROUND MIN. 16' SUBTITLE CIVIL MASTER NEW 2706 SO._ F. MODULAR Buru5ING EXISTING 18" DEEP CONCRETE TARMAC SITE VER" FLAT SITE PLAN RUNWAYS FILE COPY Permit No Plar- MIAOW approval is subject to errors and omissions. Approval of construction documents does not are the violation .. any adopted code W orb. Re stt of approved Copy and melons is acknowledged: A By .a gR Date , °$ City of Tukwila BUILDING DIVISION F22 SECURE FACILITY MISC YARD M.F.0 SHELTER AND TOOL CR CURRENT REVISION SHEET JOB NO. DWG NO. SYMBOL C80 BS 7 4 2008 -19 13-009-1C80 RECEIVED CRY OF n!KWLA APR 10 Z008 PERMIT CENTER los DATE COMP NO. HARDWARE SCHEDULE DOOR ROUGH OPENING SCHEDULE GROUP # EXTERIOR DOORS A ACTIVE LEAF METAL DOOR W/ HOLLOW METAL FRAME (WELDED) R.O. WIDTH CALL SIZE + 4 -1/2" R.O. HEIGHT CALL SIZE + 2 -1/8" 8 ACTIVE LEAF DBL. METAL DOORS W/ HOLLOW METAL FRAME (WELDED) R.O. WIDTH CALL S1ZE + 4-1/2" R.O. HEIGHT CALL S1ZE + 2 -1/8" C HINGE KRIEGER PROVIDED STOREFRONT DOOR R.O. WIDTH CALL SIZE + 4-1/2" R.O. HEIGHT CALL SIZE + 2 -1/8" D 1 -1/2 PIAR BUTTS TIMELY SPLIT MEDIA DOOR R.O. WIDTH CALL SIZE + 1 -1/4" R.O. HEIGHT CALL 517.E + 1" E #1 METAL DOOR WITH WOOD FRAME (PEASE & STANLEY) (INSWIN R.O. VADTH CALL SIZE + 2" R.O. HEIGHT CALL SIZE + 2" #2 METAL DOOR WITH WOOD FRAME (PEASE & STANLEY) (OUTSWING)R.o. WIDTH CALL SIZE + 2" R.D. HEIGHT CALL S1ZE 4 1 -9/16" F SIZE PHILLIPS DOOR #87 (WESTERN STEEL DOOR) R.O. WIDTH CALL SIZE + 1' R.O. HEIGHT GALL SIZE + 1" FLUSH BOLT T &9 CLOSER LCN P4041 METAL DOOR W/ HOLLOW METAL FRAME (KNOCK -DOWN) R.O. WIDTH CALL SIZE + 2" R.O. HEIGHT CALL SIZE + 1" CLOSER LCN P4041 INTERIOR DOORS 1 10 "x34" S.S. KICK PLATE HOLLOW / SOUP WOOD DOOR W/ WOOD FRAME R.O. WIDTH CALL SIZE + 2" R.O. HEIGHT CALL SIZE + 2 -1/8" 2 PANIC /LEVER TIMELY FRAME R.O. WIDTH CALL SIZE + 1 - 1/4" R.O. HEIGHT CALL SIZE + 1" 3 EACH SIDE POCKET DOOR R.O. WIDTH (2 x CALL SIZE) + 2" R.O. HEIGHT CALL SIZE + 4" 4 VON OUPRIN 99 VERT. RCO 51 -PASS DOOR R.O. WIDTH CALL SIZE R.O. HEIGHT CALL SIZE + 2 -1/8" 5 - 81 -FOLD DOOR FINISH WIDTH CALL SIZE FINISH HEIGHT CALL SIZE + 5/8" HARDWARE SCHEDULE GROUP # GROUP # GROUP #3 SIZE ACTIVE LEAF INACTIVE LEAF TBD ACTIVE LEAF ACTIVE LEAF FIRE HINGE KRIEGER PROVIDED HINGE KRIEGER PROVIDED HINGE KRIEGER PROVIDED 1 -1/2 PIAR BUTTS 1 -1/2 PIAR BUTTS HEIGHT (CAM LIFT) (CAM LIFT) (CAM LIFT) NRP BB NRP BB SIZE CLOSER LCN P4041 FLUSH BOLT T &9 CLOSER LCN P4041 CLOSER LCN P4041 CLOSER LCN P4041 6' -0" WEATHER- -STRIP 10 "x34" S.S. KICK PLATE WEATHER-STRIP PANIC/LEVER PANIC /LEVER PT DOOR BOTTOM EACH SIDE DOOR BOTTOM VON DUPRIN 99 MIT. ROD VON OUPRIN 99 VERT. RCO - 1/2" MAX. ACCESSIBLE - 1/2" MAX. ACCESSIBLE YALE AU5400 YALE AU5400 KRIEGER ACUOUSTICAL DOOR THRESHOLD INSIDE: YALE AL5339 3' -0" THRESHOLD PANIC /LEVER /COXO9 6 PM FIGURE 8 CYLINDER 6 PIN FIGURE 8 CYLINDER INS OUTSIDE: BLANK PT 10 "z34" 5.5. KICK PLATE 10'x34" S.S. KICK PLATE 10 "x34" S.S. KICK PLATE PT 10 "x34" 5.5. KICK PLATE - EACH SIDE EACH SIDE EACH SIDE 5505162 -43 (33 EACH SIDE KRIEGER ACUOUSTICAL DOOR DRIP EDGE PEMKO #346C 6' -0" 7' -0" 1 -3/4" DRIP EDGE PEMKO #346C INS MTL PT - -- ASTRIGAL PT 4 -7/8" G 3 - CONVENTIONAL CYLINDER 5505162 -43 (33 K51) 18 GA 000R, 16 GA FRAME DOOR SCHEDULE Lam' QTY. N0. SIZE DOOR LITE FRAME R.O. TYPE HDWR GROUP RATING FIRE FRAME HEADER SHGC REMARKS WIDTH HEIGHT THICK. HAND CORE FACE FINISH SIZE TYPE MAT'L FINISH THROAT 1 6' -0" 7' -0" 1 -3/4' DUAL INS MTL PT - - MTL PT 6 -3/4" - 1 - 2) 5505162 -43 (33 K51) KRIEGER ACUOUSTICAL DOOR 2 3' -0" 7' -0" 1 -3/4" RHOS INS MTL PT - - MTL PT 6 -3/4" - 2 - (2) 5505162 -43 (33 K51; KRIEGER ACUOUSTICAL DOOR 3 6' -0" 7' -0" 1 -3/4" DUAL INS MTL PT - -- MIL PT 4 -7/8" G 3 - (2) 5505162 -43 (33 K51) 18 GA 000R, 16 GA FRAME WINDOW SCHEDULE Lam' QTY. SIZE WINDOW TRIM HEADER REMARKS WIDTH HEIGHT TYPE FRAME GLASS SHGC U -VAL INTERIOR EXTERIOR A 2 4' -O" 3' -0" FIXED MTL BA / TMP .35 .38 TTP - (2) 550S162-43 (33 KSI) 0) ACTIVE TYPE 3R CABINET w/ (2) 4 "0 CONDUIT STUB IN 6 ". MOUNT FLUSH w/ BOT. OF SIDING. ADD TRACK BLOCKING ,AS REQ'D. USE 'C' CLOSURE AT SIDES AND BOT. 'Z' FLASH AT TOP DBL. STUD - TYP. (1) 4 "0 COUNDUIT STUB THRU WALL 6 "± EA. SIDE 20 (2) 3/8 "m EYE BOLT AT 21" & 42" ABOVE COMPUTER FLOOR EACH SIDE OF DOOR. PROVIDE VINYL WRAPED CABLE w/ 'S' HOOK AT EA. END THIS IS AN EQUIPMENT LOADING DOOR ONLY. PROVIDE SIGNAGE "NOT AN EXIT" REVISION LIEBERT UNIT ##2 1/2"0 PEX 13'-6" 27' -1" 40 O' -0 1/2" VERIFY FLOOR PLAN BY 6" ID PENETRATION TO ROOF APPROVED 9'- 7 1/2" r 36 "x37" POWER i CONDIT. # L J TEMP SHIP SUPPORT w/ BRACE EACH SIDE OPEN OFFICE DATE 1' - 0" DBL. STUD - TYP. 1 3' SYM 54' -1 1/2"± (VERIFY) ASSUME ±1/2" GAP AT M/L 2'- SIM. 1' -4 1/2" PANEL LAP DIRECTION 36 "x37" POWER CONDIT. # L a 0 / / / / in 2'- 6" ' -4 1/2" 0'--O 1/2" VERIFY REVISION 13' -6" 9' -7 1/2" (24 "x36 ") SCALE: 1/4" = 1' -0" 21' --11 1/2" 40 1/2 "0 PEX WATER LINE RUN ABOVE CEILING 40 OPEN OFF BY 11 "0 HOLE IN 7/8 CORR. FIELD CUT HOLE IN DUROCK SEE FLOOR FRAMING PLAN / ADD TRACK BLOCKING AS REQX FOR PANEL ATTACHMENT. USFf 'C' CLOSURE AT SIDES AND BO, OM AND 'Z' FLASH AT TOP / / / / / COMPRESSED AIR INTER FACE (2) COMMERCIAL SHOP DISCONNECTS (FEMALE), APPROX. 4" ABOVE TRUE FLOOR. ABLE TO PROVIDE 6 CFM AT 90 PSI - TYP. (2) PLACES 0' - 1/2" VERIFY 0 APPROVED / / / / / / < (2) 2 "0 CONDUIT SLEEVE THRU WALL ABOVE CEILING AND BELOW ROOF 6" ID PENETRATION TO ROOF SIMPSON LTTI31 w/ (10) #10 STSM (7) LOCATIONS 13' -6" DATE 1'- / C 1' -10 1 /2" 0 N O 0 Ln COMPRESSED AIR INTERFACE (1) COMMERCIAL SHOP QUICK DISCONNECT (FEMALE) APPROX. 4" ABOVE TRUE FLOOR PREVAILING WIND DIRECTION �BOE /NG NOTES: 1) CAULK AND SEAL ALL EXTERIOR DOORS. 2) ALL EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT (U.N.0.) ABBREVIATIONS AL AFF BA BV CDR CLR ALUMINUM CO ABOVE FIN. FLR. C5 BRONZE ANODIZED FGL BOTTOM VENT FP CEDAR FPT CLEAR HB COLONY OAK CAULK & SEAL FIBERGLASS FACTORY PRIMED FIELD PAINTED HARDBOARD HC HM INS KD LH LHR HOLLOW CORE HOLLOW METAL INSULATED KNOCK DOWN LEFT HAND LEFT HAND REV. MTL NRW PF PT RH RHR METAL SC NARROW (LITE) SF PREFlNISHED STN PAINT TIM RIGHT HAND TMP RIGHT HAND REV. TTP SOLID CORE VWS STOREFRONT WD STAIN WLD TIMELY FRAME TEMPERED TAPE, TEXTURE, PT VINYL WRAP SURR. WOOD WELDED PANEL LAP DIRECTION NOTE: CAULK AND SEAL ALL EXTERIOR WINDOWS. FLOOR CONSTRUCTION FINISH: 18" RAISED COMPUTER FLOOR (TATE CONCORE CC1250) BASE: 4" BLACK COVE UNDERLAYMENT: 1/2" DUROCK w/ 1.1/4" SF SCREWS AT 8" O.C. SEAL DUROCK w/ WATER BASED SEALER SUBFLOOR: 24 GA. x 7/8 GALVALUNE CORRUGATED METAL ASTM A653 GRADE 40 JOISTS: GALVANIZED STEEL JOIST AT 16" 0.C. (10005200 -54) 33 KSI RIM JOISTS: CHANNEL C10x15.3 (PRIME & PAINT BODY COLOR) OFFSET RIMS: GALVANIZED STEEL (362S162-43) INSULATION: R -19 FIBERGLASS BATTS BOTTOM CLOSURE: 30 GA. EXTERIOR WALL CONSTRUCTION PLATE HEIGHT: 12' -8 5/8" FINISH: 26 GA. STEEL PBR PANEL - GALVANIZED AND PRE-FINISHED OVER BARRIER WRAP SHEATHING: 5/8" DENS -GLASS GOLD FIREGUARD TYPE 'X' SHEATHING (NER -574) w/ 22 GA. (33 KSI) STEEL SHEET ASTM A1003 GRADE 33 TYPE H FRAMING: STUDS: 5505162 -43 33 KSI STEEL STUDS AT 24" O.C. (ER- 4943P) TRACK: 550T150 -43 AT TOP AND BOTTOM INSULATION: R -19 FIBERGLASS BATTS INTERIOR FINISH: 5/8" TYPE 'X' GYP. BD. TAPE TEXTURE AND PAINT w/ MIN. #6 x 1 -1/8" TYPE '5' AT 12" MAX. Q.C. SKIRT: MATCH SIDING INTERIOR WALL CONSTRUCTION PLATE HEIGHT: 12' -8 5/8" FRAMING: STUDS: 362S162 -43 33 KSI STEEL STUDS AT 16" O.C. (ER- 4943P) TRACK: 362T150 -43 AT TOP AND BOTTOM INSULATION: N/A INTERIOR FINISH: 5/8" TYPE 'X' GYP. BD. TAPE TEXTURE AND PAINT w/ MIN. #6 x 1 - 1/8" TYPE 'S' AT 12" MAX. O.C. IRES' 7/2/0B ACCEPTABILITY THIS DESIGN AND /OR SP iFF -IC-{ TOFF S APPROVED APPROVED BY DEPT. DRAWN L. HINES CHECKED ENGINEER DATE K. RASMUSSEN CHECKED APPROVED APPROVED 3) ALL DOOR LEADS 4 - 1/2" U.N.O. 4) ALL DOORS TO HAVE A OPENING FORCE NOT TO EXCEED 5 POUNDS. DATE 05-FEB-08 CEILING NOTES CEILING HEIGHT: 8' -4" (U.N.O.) SUSPENDED T -GRID W/ ACOUSTIC TILE (REF: MFR'S INSTALLATION DATA) INSTALL SUSPENDED CEILING PER IBC ASTM C635, C636 AND ESR -1308 ATTACH LIGHT FIXTURES TO CEILING GRID W/ (4) #6 x 1" STSM SCREWS ATTACH HVAC DIFFUSERS TO CEILING GRID W/ (4) #6 x 1 STSM SCREWS LIGHT FIXTURES SHALL BE INDEPENDENTLY SUPPORTED BY 12 GA. WIRES AT EACH CORNER ROOF CONSTRUCTION ROOFING: MIN. 45 MIL. TPO MEMBRANE MECHANICALLY FASTENED (SYSTEM #1 MIN. CLASS A ER -6030 SYSTEM ##3 ATTACHMENT) SHEATHING: 24 GA. x 7/8 GALVALUNE CORRUGATED METAL ASTM A653 GRADE 40 FRAMING: GALVANIZED STEEL JOIST AT 24" O.C. (6005200 -54) 33 KSI BEAMS: A36 STEEL TRUSS (PRIME AND PAINT) INSULATION: 4" RIGID POLYISO R -25 OVERHANG: NONE ROOF PITCH: 1/4 IN 12 EXTERIOR NOTES CORNER BATTS: MATCH SIDING FASCIA: MATCH SIDING BARGE: MATCH SIDING STRUCTURAL NOTES - DESIGN INFO ASCE STANDARD 7 -05 AISI STANDARD WALL STUD DESIGN 2004 EDITION AISI STANDARD LATERAL DESIGN 2004 EDITION STEEL DECK INSTITUTE DIAPHRAM DESIGN MANUAL 3rd EDITION SUBTITLE TITLE FLOOR PLAN F22 SECURE FACILITY ARCHITECTURAL MASTER YARD OCCUPA\ OFFICE: EXTERIOR WALLS TOTAL DATA LIST SQ. FOOTAGE: EXT. WALL LIN. FOOTAGE: INT. WALL LIN. FOOTAGE PROJECTED ROOF AREA: REVIEWED FOR CODE COMPLIANCE ,APPROVED MAY -1 2008 City Of Tukwila B . _ DID :_J , NOTE: ALL TRIMMER HEIGHTS = R.O. CALL SIZE - 1 -1/2" M.F.C. CURRENT REVISION SHEET JOB NO. DWG NO. T LOAD CALC U LATI O \ (o? A10 2008 -19 (2644 S.F.) /(100) (62 S.F.) (2706 S.F.) SYMBOL DATE COMP NO. 2706 S.F. 209 L.F. 50 L.F. 2708 S.F. ECEIVE CITY R OF A LA APR 10 2008 PERMIT CENTER 27 0 27 13- 009 -1A10 V , ■ ,.; �,4 ., . .a ♦ �� � * ♦. �� i �,4 ∎•i 014! . V " �• 4 • : , 4 :4 •,a t ,a r : • *; ��4 . � ■ • • 144 �: �.�� ♦� �� �: ��� +mot � F irrAi ►"`►! i! i! i! i! i! i! i! i! i! i !i!i'i!i!i!i!i!i!i!i!i!i *i!���� rati, i �i!i!'i! ♦�,� 1� 1 '1;, i I 00 CFM : r I .• • •* •. • *+ . Vii THERMASTAT FOR HVAC UNIT (B) 6 "0 8" ii 8 "0 +* . I i hi ...::__._:77;.7:71;27777.7•7' 200 + *� i 200 .: ii. +; CFM I %i % CFM : + i ♦, i i i i ►♦ ♦ r. .i i ii i ♦ * i P� . 4 iii .� ♦ �« is . • . � ,f +A f ., 8" 0 ��. ii 8 " � i +4 i_. .,� � ', 4. . . .,, r i�%%i�% %ii % %i�i'%iwi4i i % % ►; iii :, 200 ► 1 ♦ 0 200 ► • a • : • CFM • % % . % C FM ► i i �1 �i ► ∎i ∎i : i ii i i i' 0. ♦i �� iii • ►i i ' i ♦ i ' I. iI i . ♦ i ∎ ii i� ► ♦� � f i� 04.11.1 i i i� ' • ' *� � ► *+ � �' !i� I - i i i ■ � ■ • ' :♦i ' . ►i Iii ■ 0 , � ;: :. :4 iii - MECH. UNIT B CFM CFM I : i o �+ +• :a o f ., . +* :, i s 8 "0 h i Mr MIL ti, ��� 200 mi . . 200 1:% CFM +. i• i ♦i r:11 r i. ra r . +� i i! i rV ►♦ ► ►♦ i! ii i i to r a r , . r 4 r . ... 8-0 : 4 . • 6 "0 30" x 10" GALV. SHEET METAL x 24GA. S/A DUCT ECHA\ 30" x 16" R/A WALL GRILLE (1400 CFM) i PLA\ SYM REVISION BY APPROVED DATE SYM REVISION 12" x 8" ACCESS DOOR (24 "x36 ") SCALE: 1 /4" = 1' -0" BY APPROVED DATE L g LA OE / NG XPIRES' 7/2/08 6 1/2"O STEEL BAR 1 /2 "0 STEEL BAR SECURITY BAR IN SUPPLY DETAIL 2'--6" 6" 6" SECURITY BAR IN RETURN DETAIL MOV 1)'3 ACCEPTABILITY THIS 'ESIGN AND /OR FICATION IS APPROVED APPROVED BY DEPT. DATE ERAWN L. HINES CHECKED ENGINEER K. RASMUSSEN CHECKED APPROVED APPROVED DATE 05— FEB -08 SCALE: 3" = 6 SCALE: 3" - 1' -0' SUBTITLE TITLE 6 ARCHITECTURAL MASTER YARD 2" x 11 GA. FRAME RIVIT TO DUCT. 6" MAX SPACING r - 2 " x 11 GA. FRAME RIVIT TO DUCT. 6" / MAX SPACING MECHANICAL PLAN F22 SECURE FACILITY O MECHANICAL UNIT(S): (2) 3.5 TON WALL HUNG HEAT PUMPS WITH 9 kw ELECTRICAL HEAT (460V 3 PHASE) 0 x SYMBOL LEGEND 2' x 2' LAY —IN SUPPLY DIFFUSER 0 THERMOSTAT AT 48" A.F.F. TO TOP OF CONTROLS MECHANICAL NOTES THERMOSTAT(S): WR 1F93 -380 THERMOSTATS FOR WALL HUNG MECHANICAL UNITS (A) & (B) TO BE INTERLOCKED WITH LIEBERT AIR HANDLER TEMPERATURE CONTROLS TO PREVENT SIMULTANEOUS HEATING AND COOLING O DUCT MATERIAL: 26 GA. SHEET METAL O ECONOMISER(S): S ECONOMISER(S) AND CONTROLS ❑ COMMERCIAL ROOM VENTILATORS ❑ NO ECONOMISER(S) O VOLUME DAMPERS: PROVIDE VOLUME DAMPERS TO CONTROL AIRFLOW AT EACH DIFFUSER O SYSTEM COMMISSIONING: MECHANICAL SYSTEM TO BE TESTED AND DOCUMENTED IN ACCORDANCE WITH WSEC SECTION 1416. OUTSIDE AIR CALCULATION O MECHANICAL UNIT A: OFFICE: (27 OCC)(20 CFM) = 540 TOTAL — 540 O MECHANICAL UNIT B: OFFICE: (27 OCC)(20 CFM) = 540 TOTAL = 540 M.F.C. REVI EWED FOR CODE COMPLIANCE APPROVED MAY - 1 2008 City Of Tukwila ILDIN D IO CURRENT REVISION SHEET JOB NO. DWG NO. 2008 -19 SYMBOL M / \ RECEIVED CITY OF TUKWI A APR 10 Z008 PERMIT CENTER DATE 13-009-1M10 COMP NO. L v t « */ � „Z/ L 2 1 „ 1. 2 i W 6" 6" 6" l' 6" ir' 6" 1 X X V , ■ ,.; �,4 ., . .a ♦ �� � * ♦. �� i �,4 ∎•i 014! . V " �• 4 • : , 4 :4 •,a t ,a r : • *; ��4 . � ■ • • 144 �: �.�� ♦� �� �: ��� +mot � F irrAi ►"`►! i! i! i! i! i! i! i! i! i! i !i!i'i!i!i!i!i!i!i!i!i!i *i!���� rati, i �i!i!'i! ♦�,� 1� 1 '1;, i I 00 CFM : r I .• • •* •. • *+ . Vii THERMASTAT FOR HVAC UNIT (B) 6 "0 8" ii 8 "0 +* . I i hi ...::__._:77;.7:71;27777.7•7' 200 + *� i 200 .: ii. +; CFM I %i % CFM : + i ♦, i i i i ►♦ ♦ r. .i i ii i ♦ * i P� . 4 iii .� ♦ �« is . • . � ,f +A f ., 8" 0 ��. ii 8 " � i +4 i_. .,� � ', 4. . . .,, r i�%%i�% %ii % %i�i'%iwi4i i % % ►; iii :, 200 ► 1 ♦ 0 200 ► • a • : • CFM • % % . % C FM ► i i �1 �i ► ∎i ∎i : i ii i i i' 0. ♦i �� iii • ►i i ' i ♦ i ' I. iI i . ♦ i ∎ ii i� ► ♦� � f i� 04.11.1 i i i� ' • ' *� � ► *+ � �' !i� I - i i i ■ � ■ • ' :♦i ' . ►i Iii ■ 0 , � ;: :. :4 iii - MECH. UNIT B CFM CFM I : i o �+ +• :a o f ., . +* :, i s 8 "0 h i Mr MIL ti, ��� 200 mi . . 200 1:% CFM +. i• i ♦i r:11 r i. ra r . +� i i! i rV ►♦ ► ►♦ i! ii i i to r a r , . r 4 r . ... 8-0 : 4 . • 6 "0 30" x 10" GALV. SHEET METAL x 24GA. S/A DUCT ECHA\ 30" x 16" R/A WALL GRILLE (1400 CFM) i PLA\ SYM REVISION BY APPROVED DATE SYM REVISION 12" x 8" ACCESS DOOR (24 "x36 ") SCALE: 1 /4" = 1' -0" BY APPROVED DATE L g LA OE / NG XPIRES' 7/2/08 6 1/2"O STEEL BAR 1 /2 "0 STEEL BAR SECURITY BAR IN SUPPLY DETAIL 2'--6" 6" 6" SECURITY BAR IN RETURN DETAIL MOV 1)'3 ACCEPTABILITY THIS 'ESIGN AND /OR FICATION IS APPROVED APPROVED BY DEPT. DATE ERAWN L. HINES CHECKED ENGINEER K. RASMUSSEN CHECKED APPROVED APPROVED DATE 05— FEB -08 SCALE: 3" = 6 SCALE: 3" - 1' -0' SUBTITLE TITLE 6 ARCHITECTURAL MASTER YARD 2" x 11 GA. FRAME RIVIT TO DUCT. 6" MAX SPACING r - 2 " x 11 GA. FRAME RIVIT TO DUCT. 6" / MAX SPACING MECHANICAL PLAN F22 SECURE FACILITY O MECHANICAL UNIT(S): (2) 3.5 TON WALL HUNG HEAT PUMPS WITH 9 kw ELECTRICAL HEAT (460V 3 PHASE) 0 x SYMBOL LEGEND 2' x 2' LAY —IN SUPPLY DIFFUSER 0 THERMOSTAT AT 48" A.F.F. TO TOP OF CONTROLS MECHANICAL NOTES THERMOSTAT(S): WR 1F93 -380 THERMOSTATS FOR WALL HUNG MECHANICAL UNITS (A) & (B) TO BE INTERLOCKED WITH LIEBERT AIR HANDLER TEMPERATURE CONTROLS TO PREVENT SIMULTANEOUS HEATING AND COOLING O DUCT MATERIAL: 26 GA. SHEET METAL O ECONOMISER(S): S ECONOMISER(S) AND CONTROLS ❑ COMMERCIAL ROOM VENTILATORS ❑ NO ECONOMISER(S) O VOLUME DAMPERS: PROVIDE VOLUME DAMPERS TO CONTROL AIRFLOW AT EACH DIFFUSER O SYSTEM COMMISSIONING: MECHANICAL SYSTEM TO BE TESTED AND DOCUMENTED IN ACCORDANCE WITH WSEC SECTION 1416. OUTSIDE AIR CALCULATION O MECHANICAL UNIT A: OFFICE: (27 OCC)(20 CFM) = 540 TOTAL — 540 O MECHANICAL UNIT B: OFFICE: (27 OCC)(20 CFM) = 540 TOTAL = 540 M.F.C. REVI EWED FOR CODE COMPLIANCE APPROVED MAY - 1 2008 City Of Tukwila ILDIN D IO CURRENT REVISION SHEET JOB NO. DWG NO. 2008 -19 SYMBOL M / \ RECEIVED CITY OF TUKWI A APR 10 Z008 PERMIT CENTER DATE 13-009-1M10 COMP NO. Dimensional Data, in_ (mm) Model A B Air - Cooled Semi - Hermetic Models and All VVater/Glycal /GLYCOOL Models 108 (2743) 26 (660) (---------- r 7 36 ° x37" POWER CONDIT rT 1 36 "x37" POWER CONDIT I I ~ L..._ #2 L__ # ! 1 I I / _ IEBERT DS DJWNFLOW =LODR MOUNTEDAIR COCLED / v1ODEL # DSO77AMA 3' -0" EL' 22A LIEBERT UNIT #2 1/4" CU SWEAT LIEBERT UNIT #1 1/4" CU SWEAT . r� 1 ,„0 -, r 1 1 -1/8 "o LIQUID LINE ,11 MECH. UNIT B 14 MECH. UNIT A W ELECTRICAL FROM INDOOR UNIT /FOR OO NUNIT HAS DISCONNECTS 1 -3/8 "o HOT GAS LINE 1/2" PEX II , I 1 I I i Li 21 — 10' -8'� 0 ---,, VERIFY 5/8" "4 X LIEBERT AIR COOLED CONDENSER MODEL # DCDF308 —A REVISION ELECTRICAL FROM INDOOR UNIT (INDOOR UNIT HAS DISCONNECT FOR CONDENSER) BY APPROVED DATE SYM 1 -1/8 % LIQUID LINE) 1 -3/8 "o HOT GAS LINE REVISION LIEBERT AIR COOLED CONDENSER MODEL # DCDF308 —A BY APPROVED DATE COMPUTER FLOOR AratE,Afga® 1 EXPIRES1 7/2/08 43 -3/16" (1097mm) 131 -1/2" (3340mm) M ACCEPTABILITY S DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN L. HINES CHECKED ENGINEER K. RASMUSSEN CHECKED APPROVED APPROVED DATE 05— FEB --08 (457mm) 124" (3150mm) SUBTITLE TITLE 43 -9/16" (1106rnm) 37 -7/8" (962mm) ARCHITECTURAL MASTER Electric Box Legs supplied with End '28- 42kW Dig ita 53-7OkW Digital Solenoid Valve brL LJ 34 -112" (876mm) (with feet) 33' (83 m} 42 ir (1 067 mm YARD 0 Lee -Temp option only Figure 2 Typical system configuration— indoor unit and outdoor condenser and field piping t Inverted trap on discharge & liquid lines to extend above base of coil by a minimum of 7 -1/2" (190mm). Condenser Coil (Fan Speed and VFD) Fusible Plug ..__ _ ..... t 4r 4 Fan Speed and VFD Liquid Cle Solenoid Valy Service Valve Service Compressor Va Check Valve F22 SECURE FACILITY ANCHOR PLAN t 1" (25mm) TYP. Gussets supplied on floor stands 12" (305 mm) tall and greater COMPUTER FLOOR COOLING PLAN Sensing Bulb Suction A +1 -1/2" (38mm) (with feet) A External Equalizer Turning vane air outlet Optional turning vane can be field - installed in supply air discharge opening for front or rear air discharge. 122" (3099 mm) 1 1 41-3116" I (1046mm) Three-Fan Condenser Relief Check Valve Valve Condenser Coil (Lee -Temp) Pitch horizontal hot gas plprrg 1/2" per 10ft. (42iim per 1Ctn) in direction of refrigerant+oil flaw. Filter Dryer Figure 54 Floor stand dimensions - downflow, 53 -T7kW (15 -22 ton) models 69 -3I4_ (1772mm) Lee -Temp Zarriffr Supply air discharge opening gr..1.1 Table 65 Floor stand and floor planning dimensional data Evaporator Coil M.F.C. CURRENT SHEET JOB NO. DWG NO. 1 /2 "ox 6" WEDGE ANCHOR (2) PER LEG – TYP. Field- installed relief valves) required for 50 Hz EU CE units rated maximum 480 PSIG (33 Bar). Expansion Solenoid Sight Glass Valve Valve Factory Refrigerant Piping — Field Refrigerant Piping v Service /Schrader (Access) Connection No Valve Core Service /Schrader (Access) Connection With Valve Core Note: Schematic representation shown . Do not use for specific connection locations. Two refrigeration circuits provided . Single refrigeration circuit shown for clarity . 4 -1/2" (114mm) 16 -3/4" (425mm) Service Valve Liquid Return Hot Gas Discharge REVISION 1 l * Traps every 1 25ft (7.6m) of rise Height, in. (mm) c* Dturning vane 9 (229) 12 (305) 15.(381) 18 (457) 21 (533) 24 (610) 4(111) 7 (187) 10 (264) 13 (340) 16 (416) 19 (492) M11 SYMBOL Head Pressure Control Valve 2008 -19 13-009-1M11 Optional turning vane shown as front air discharge. 'i * Isolation CF valve Hot Gas Discharge Liquid Return * Isolation valve * Components are not supplied by Lieberl; but are recommended for proper circuit operation and maintenance D P N000798 Rev. 2 NOTE: Right side of paneled unit is flush with right side of floor stand. All other paneled sides overhang floor stand 1" (25mm). * Leveling feet are provided with t 1 -1/2" (38mm) adjustment from nominal height C. DPN000930 REV 1 RECEIVED CITY oF '1U-IKWILA APR 10 [U8 PERMIT CENTER DATE COMP NO.