HomeMy WebLinkAboutPermit M08-111 - WESTFIELD SOUTHCENTER MALL - GENERAL NUTRITION CORP (GNC)GENERAL NUTRITION
CORD
978 SOUTHCENTER MALL
M08 -111
Parcel No.: 6364200010
Address:
Suite No:
Tenant:
Name:
Address:
Owner:
Name:
Address:
978 SOUTHCENTER MALL TUKW
Contact Person:
Name: MARTHA MARTIN
Address: 1327 POST AVE SUITE #H , TORRANCE CA
Contractor:
Name: SOUND HEATING & A/C INC
Address: 5209 122 ST E , TACOMA, WA
Contractor License No: SOUNDHA066BM
DESCRIPTION OF WORK:
NEW PERMIT FOR EXPIRED APPLICATION (M07 -151). NEW SPLIT SYSTEM.
Value of Mechanical: $11,500.00
Type of Fire Protection:
Furnace: <100K BTU 1
>100K BTU 0
Floor Furnace 0
Suspended/Wall/Floor Mounted Heater 0
Appliance Vent 0
Repair or Addition to Heat/Refrig /Cooling System.... 1
Air Handling Unit <10,000 CFM 0
>10,000 CFM 0
Evaporator Cooler 0
Ventilation Fan connected to single duct 0
Ventilation System 0
Hood and Duct 0
Incinerator: Domestic 0
Commercial/Industrial 0
doc: IMC -10/06
CitAif Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
GENERAL NUTRITION CORP
978 SOUTHCENTER MALL , TUKWILA WA
WESTFIELD PROPERTY TAX DEPT
PO BOX 130940 , CARLSBAD CA
MECHANICAL PERMIT
EQUIPMENT TYPE AND QUANTITY
* *continued on next page **
M08 -111
Permit Number:
Issue Date:
Permit Expires On:
Phone:
Phone: 310 - 328 -6300 X104
Phone: 253 - 535 -6249
Expiration Date: 08/15/2009
M08 -111
07/08/2008
01/04/2009
Fees Collected: $305.00
International Mechanical Code Edition: 2006
Boiler Compressor:
0 -3 HP /100,000 BTU 0
3 -15 HP /500,000 BTU 0
15 -30 HP /1,000,000 BTU.. 0
30 -50 HP /1,750,000 BTU.. 0
50+ HP /1,750,000 BTU 0
Fire Damper 0
Diffuser 6
Thermostat 1
Wood/Gas Stove 0
Water Heater 0
Emergency Generator 0
Other Mechanical Equipment
Printed: 07 -08 -2008
Permit Center Authorized Signature:
Signature:
Print Name: �� ■•■ V�� ♦ L .L. Es
doc: IMC -10/06
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tukwila.wa.us
Permit Number: M08 -111
Issue Date: 07/08/2008
Permit Expires On: 01/04/2009
Date: 1 9-08
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this mechanical permit.
Date: -7 c ti` c
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
M08 -111 Printed: 07 -08 -2008
Parcel No.: 6364200010
Address:
Suite No:
Tenant:
1: ** *BUILDING DEPARTMENT CONDITIONS * **
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
978 SOUTHCENTER MALL TUKW
GENERAL NUTRITION CORP
PERMIT CONDITIONS
Permit Number:
Status:
Applied Date:
Issue Date:
M08 -111
ISSUED
04/22/2008
07/08/2008
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
this requirement.
7: Manufacturers installation instructions shall be available on the job site at the time of inspection.
8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila
Permit Center.
9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431- 3670).
10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
11: ** *FIRE DEPARTMENT CONDITIONS * **
12: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the
following concerns:
13: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned
in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051)
14: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be
equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the
air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors
shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the
doc: Cond -10/06
M08 -111 Printed: 07 -08 -2008
doc: Cond -10/06
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
* *continued on next page **
manufacturer's installation instructions. (IMC 606.1, 606.2.1)
15: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051)
16: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051)
17: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051)
18: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire
Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC
104.2)
19: An electrical permit from the City of Tukwila Building Department Permit Center (206 -431 -3670) is required for this
project.
20: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and
#2051)
21: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of
such condition or violation.
22: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at
(206)575 -4407.
M08 - 111 Printed: 07 -08 -2008
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work
construction or the performance of work.
Signature: 6 .4
Print Name: U trti� V�MJ` (.l�1fL
doc: Cond -10/06 M08 -111
Date: - 7 `W.UE_
ordinances governing
or local laws regulating
Printed: 07 -08 -2008
how
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http:. > itiu °its. ci. tulnt'iln.iva. its
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
C' � y��p M King Co Assessor's Tax No.: 3 ( `f 223 -6 d [ j}
Site Address: 1 1 i CQ 1 I Il l 1 ii Suite Number — Floor 1
( u U1rit on COT. COI NG) New Tenant:
Tenant Name:C \enQ i
Canifr
City
Property Owners Name:
Mailing Address:
E -Mail Address:
Name: M r*hCJ r r-h
Mailing Address: 1 321 Post
GEN
(Contrite
Company Name:. n / e
Mailing Address: 26+1 r ' 5th_l'sV• S.
Contact Person:11 t l ni IIQ r
E -Mail Address:km(0,1st i IC @QO1'can
r: EM Registration Numbej Cdt * n33 VD
cal stnic %
Company Name: _ CO 1SL I n 1 t
Mailing ddress: 1 1 L Q f1 �
g � g 1 , t � -t�
Contact Person: t &CknW
E -Mail Address: J
Company Name:
Contact Person:
eit
❑ Yes
u1Pr
state
State Day Telephoned 5 3- $ 3. 2%5
Fax Number:2 ,I •G S► y
Expiration Date: S / 20 1 O
State
ve)
qtyAs
Day Telephone: .10.72z. ) X +. ( 04
Su 1+e H 'Mi n c2 CA Gaso►
City 2 f Zip
X Number: 3I O • state ` .1 1 Z
� n ArlDni ytX 1 gel
City } State Q Zip
Day Telephone: ` o. gob- LI Ob . 1 130
Fax Number: Z 1 n . 21
6
Mailing Address:
City
Day Telephone:
E -Mail Address: Fax Number:
Q: Wpp0catiauWonnI- Applations On Line\3 -2006 - Pmmit Application.doc
Revised: 9 -2006 Page 1 of 6
bh
Zip
Unit Tv e:.
P
tt .
Q -
.
Unit Type:
'[►
Q t<> :.
Unit T� e.:.. .
_ p
�
$o[ler /compressor; .
- .
Furnace <100K BTU
I
Air Handling Unit : 10.000
CFM
Fire Damper
0 -3 HP /100,000 BTU
Furnace 100K BTU
Evaporator Cooler
Diffuser
0
3 - 15 HP.'500.000 BTU
Floor Furnace
Ventilation Fan Connected
to Single Duct
Thermostat
�
15 -30 HP. L000.000 BTU
Suspended/Wall /Floor
Mounted Heater
Ventilation System
Wood/Gas Stove
30 -50 HP /1,750,000 BTU
Appliance Vent
Hood and Duct
Emergency
Generator
50+ HP /1,750,000 BTU
Repair or Addition to
Heat/Refrig/Cooling
System
I
Incinerator - Domestic
I.
Other Mechanical
Equipment
Air Handling Unit
1(}.(H)0 CFM
Incinerator — Cotnm/Ind
4
MECHANICAL PERMIT INF()RM - 206 - 43 -3670
MECHANICAL CONTRACTOR INFORMATION
Company Nam& Sc&u nd N-ea-h ng 4 1 Air
Mailing Address: e j 20 I C't ' Ecl]T- Poyi pop WI c
Contact Person: Ted
ed
E -Mail Address: a G E
Contractor Registration Number: SCU n cI t P o
Valuation of Mechanical work (contractor's bid price): 011500
q
Scope of Work (please provide detailed information): , spy i-1- S9S
Use Residential: New ❑ Replacement .... ❑
Commercial: New .... ❑ Replacement ..
Fuel Type: Electric . Gas .... ❑ Other:
Indicate type of mechanical work being installed and the quantity below:
Q: \Applications\Fonne- Applications On Line\ -2006 - Permit Application.dnc
Revised: 9 -2006
bh
c ity ^� state c 2 ? Zip
Day Telephone: 2 '3 • i1 .7 7 SO
Fax Number: 2;3. b15. 02b5
co EM " 1 Expiration Date: b- 1S- Q c\
Page 4 of 6
PERMIT APPLICATION NOTES Applica,*to all niits this application
Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
BUILDIN
Signature:
Print Name:
Mailing Address: t
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
R OR . UT AGEN
Date Application Accepted:
Q: ApplicetionelFona - AppGeatioro On line\3 -2006 - Permit Appbealion.doc
Revised: 9 -2006
bh
Date: c3/ 124 zcce
Day Telephone:
City
Zip
Date Application Expires:
Staff Initials:
Page 6 of 6
Receipt No.: R08 - 02443
Payee: J E M CONSTRUCTION
ACCOUNT ITEM LIST:
Description
MECHANICAL - NONRES
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 6364200010 Permit Number: M08 -111
Address: 978 SOUTHCENTER MALL TUKW Status: APPROVED
Suite No: Applied Date: 04/22/2008
Applicant: GENERAL NUTRITION CORP Issue Date:
Initials: WER Payment Date: 07/08/2008 09:09 AM
User ID: 1655 Balance: $0.00
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 9410 244.00
Account Code Current Pmts
000.322.102.00.0 244.00
Total: $244.00
Payment Amount: $244.00
4555 07/08 9711 TOTAL 524.30
doc: Receiot -06 Printed: 07 -08 -2008
a 1
Receipt No.: R08 -01264
Initials: WER
User ID: 1655
Payee: EXPRESS PERMITS
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www. ci. tukwila. wa. us
City of Tukwila
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 11485 61.00
ACCOUNT ITEM LIST:
Description
PLAN CHECK - NONRES
RECEIPT
Parcel No.: 6364200010 Permit Number: M08 -111
Address: 978 SOUTHCENTER MALL TUKW Status: PENDING
Suite No: Applied Date: 04/22/2008
Applicant: GENERAL NUTRITION CORP Issue Date:
Account Code Current Pmts
000/345.830 61.00
Total: $61.00
Payment Amount: $61.00
Payment Date: 04/22/2008 10:55 AM
Balance: $244.00
1471 04/22 9710 TOTAL
61=00
doe: Receiot -06 Printed: 04 -22 -2008
Project:
Type of Ipspecti n:
\ _
Address P +r
J t
Date Called:
--�
Special Instructions:
Date W ted:
q -dpi'
a.rn
p
Requester:
Phone No:
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
'Approved per applicable codes.
INSPECTION RECORD
Retain a copy with permit
NO& )
PERMIT NO.
(206)431 -3 7
El Corrections required prior to approval.
COMMENTS:
r M,+ C st t &( (r'
'Dat
$60 Ob REINSPECTION FEE REM) ED. Prior to inspection, fee must be
pai t 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.: 'Date:
Project: .. _ It.. j c
Type of Ins ection: --`
Address:
(
Date C 1 e 11
Special Unstruc
3
V V \
Date Wanted: a.m.
Requester:
�`'�!
N- /
Phone 7 I"7(„ _t6 t -q ‹c C-)
INSPECT! N NO.
CITY O TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
%Approved per applicable codes.
INSPECTION RECORD
Retain a copy with permit
0 1°84 I 1
PERMIT NO.
(206)431 -3
Corrections required prior to approval.
COMMENTS:
$ .00 REINSPECTION F E REQUI ED. Prior to inspect on, fee must be
d at 6300 Southcenter : lvd., Sui a 100. Call to schedule reinspection.
Receipt No.:
Daft:
Date:
r
1/
Project:
Type ln : y
h'►
O �
Address: 76 mini
Date Called:
Special Instructions:
Date ,
( 7 - - o j
p.m.
Requester:
Phone No:
3
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 7
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
COMMENTS:
.r.
Dat
0 6 00 REINSPECT! QJIJ FEE R QUIRED. Prior to inspection, fee must be
d at 6300 Southcenter Blv ., Suite 100. Call to schedule reinspection.
Receipt No.: 'Date:
Approved per applicable codes. El Corrections required prior to approval. •
COMMENTS:
Type Inspection:
R-r , .I #k
.-S
`, - L 1:1 A -
r r 4 �--
..)A s L. (J ,'' .,Psi. =7 k [_.
Date Wanted: 8- -
l,, , i j I /riSu IC -
a.m.
-p.m.
Requester:
Flu 0 Q r . ' �.3 1 f c.f"(rr .. 7')
"76
.6J
�- , e l (1- .- c , ,) ( i N ,{tom f j t „,.._
I A
Project: , 1l p ) f✓ ! Isi A A
/ V
Type Inspection:
R-r , .I #k
.-S
Addres r s � . C
1 _(_ A /
Date Called: /
Special Instructions:
Date Wanted: 8- -
J�
a.m.
-p.m.
Requester:
-
Phone No:
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION Q-
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Approved per applicable codes.
c) ,�
Corrections required prior to approval.
Inspector:
.L,A A
'
Date:
c5� 6 ' c
$58.00 REINSPECTION FEE REQUIRED. Prior &inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection.
Receipt No.:
Date:
tdCl .t. - ae mk 4I.10. n.ze.a rle0 tr. •
COMMENTS:
/ y lJ1 pct - 1 -- fly pdOJ k
Type of Inspection:
+
t t: (t 4 l l co,/ -4 .G-ey rF.-7- 1 - -� r --.
F c- Leo - I t P .2 f.., - t -
!,^
` I
Date Called is k < t r1/4./
Special Instructions:
Date Wanted:
N
Projec
Ale 1./
N e
Type of Inspection:
+
Address
!,^
` I
Date Called is k < t r1/4./
Special Instructions:
Date Wanted:
�11r-
P•
Requester:
Phone No:
7 53. 606 -c
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY •OF TUKWILA BUILDING DIVISION 't
6300 Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Approved per applicable codes. ❑ Corrections required prior to approval.
to
IDate: 25-
0108 i
60.00 REINSPECTIOMFEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
(Receipt No.:
'Date:
b
COMMENTS:
Sprinklers:
Fire Alarm:
Type of Inspection:
P2 , iv,e't � //A ! /)1 L (r
_
/' � dr'
� 'Z_-
Pre -Fire:
Address: I J
Suite #:
�
41
/ f/
Contact Person:
P,7i. / /lf., -7? . ivIr2 -
- ,<#
Special Instructions:
Phone No.:
3 — ' L ( , - - 5y2 3
i c a
J .:, -. 7 ._ --
(i V___
' TL: s7)
(v( let v s w f TC 1,
.
1 -7-- kti F-
/ T -
F
/vf$Z.._ —
ZilZ--_ -
,g 571 t.iAC S - ,1/u n1 r 1 , -r i61 ; r, Ai 411i'1 ,/l s
---
4 /1,/ i n /, y
fL
AA/41 _
)e---
t
()X 7b ..roc e //CC (, /'V
%- vz 2 1 A/6 /A!; � '� r'a 1/
Project: dn/6
Sprinklers:
Fire Alarm:
Type of Inspection:
P2 , iv,e't � //A ! /)1 L (r
_
/' � dr'
� 'Z_-
Pre -Fire:
Address: I J
Suite #:
�
41
/ f/
Contact Person:
Special Instructions:
Phone No.:
3 — ' L ( , - - 5y2 3
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
INSPECTION NUMBER
CITY OF TUKWILA FIRE DEPARTMENT
Approved per applicable codes.
INSPECTION RECORD
Retain a copy with permit
Word /Inspection Record Form.Doc 1/13/06
444 Andover Park East, Tukwila, Wa. 98188 206 -S7S-
Corrections required prior to approval.
Inspector: 4 /4: ,z- Date: , , - / / 4/ 7 / / ,).2
$80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
e City of Tukwila Finance Department. Call to schedule a reinspection.
T.F.D. Form F.P. 113
Project Info
Project Address GNC - South Center Mall
Date 4/16/2008
l 'Z1-shaa South Center Mall
For Building Department Use
Tukwila, WA 98188
Applicant Name: Bob Dobrowaky
Applicant Address: c c
Applicant Phone: (412) 338 -8975
2006 Washington State Nonresidential Energy Code Compliance Forms
2006 Washington State Nonresidential Energy Code Compliance Form AA
roJec
u mm a r�
F "
tlOS'lfl
`REVI 1 -
CODE COMPLIOCE
APPROV
Mpy _ 1 2008
8492
GREG T.
STATE OF V
REGISTERED
ARCHITECT
Revised July 2007
RECEIVED
APR 2 2 2008
PERMIT CENTEU
Project Info
Project Address
GNC - South Center Mall
Date 4/16/2008
Equip
ID
911 South Center Mall
For Building Dept. Use
. 1 A
Capacity
Btu /h
Tukwila, WA 98188
Applicant Name:
Bob Dobrowsky
Applicant Address:
GNC
Applicant Phone:
(412) 338 -8975
Equipment Schedules
The following information is required to be incorporated with the mechanical equipment schedules on the
plans. For projects without plans, fill in the required information below.
Cooling Equipment Schedule
Equip
ID
Brand Name'
Model No.'
Capacity
Btu /h
Total CFM
OSA CFM
or Econo?
SEER
or EER
IPLV
Location
Carrier AHU _
FX4A -036 -008
36000
900
200
13.00
cv
above clg
Carrier CU
38YXA -036
Heating Equipment Schedule
Equip.
ID
-
Brand Name'
Model No.
Capacity
Btu /h
Total CFM
OSA cfm
or Econo?
Input Btuh
Output Btuh
Efficiency
Carrier AHU
8 KW electric heat
27304
900
200
Fan Equipment Schedule
Equip.
ID
Brand Name'
Model No.
CFM
SPt
HP /BHP
Flow Control
Location of Service
Existing toilet fan
existing to remain
100
0.25
0.10
cv
toilet room
2006 Washington State Nonresidential Energy Code Compliance Form
echanica
umm
2006 Washington Stale Nonresidential Energy Code Compliance Forms
Reviseo July 2007
Project Description
Briefly describe mechanical
system type and features.
El
Includes Plans
Compliance Option
Existing 3 -ton split system to be replaced with newer uge
REGISTERED
ARCHITECT
Q Simple System 0 Complex System 0 Systems Analysis
(See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple &
Drawings must contain notes requireing compliance with commissioning requir ents T, 6J
STATE OF iv
NG
0
'If available. 2 As tested according to Table 14 -1A throdgh 14 -1G. 3 If required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as
applicable 5 Flow control types variable air volume(VAV), constant volume (CV), or variable speed (VS).
System Description
See Section 1421 for full description
of Simple System qualifications.
If Heating /Cooling
or Cooling Only:
* / Constant vol?
N Air cooled? Packaged sys? <20,000 Btuh?
Economizer included?
® Split system?
If Heating Only:
9 Y
<5000 cfm?
o
� <70 /° outside air?
2006 Washington State Nonresidential Energy Code Compliance Form
�•Itr... dt.1 - SW r 7 1 f a''_.' r1 I , .
echanica Summary (bac
CH =SUM
Decision Flowchart
START
Use this flowchart to determine if project qualifies for Simple System Option. If not, either the
Complex System or Systems Analysis Options must be used.
0g
i
k
1
< System Type j
\ � i
Heating Only
T
<5000
cfm? �- Yes
No
<70% OSA
I Reference
Section 1421
Yes*
Heating /Cooling
or Cooling Only
T .
- 'Srngle
Package >
Yes \Unit ?.' -
Air Cooled,
Constant Vol?
N Cool Cats, Outdoors
Econo -No_►< <20.000 -No►< °f }Yes
N.�cluded? BtuM, �_ Adjacent to ,
N ,% N / , Outdoorsy
T Yes
Yes
_7
Simple System
Allowed
(section 1420)
I Reference
Section 1423
Yes
Yes
/Total Ca
wo economize
<240,000 Btuh
or 10 %?
Yes
No
- \
plit Systerfr.,
<=84,000
No
No
8492
•ol Ca.
<54,000
Btuh ?,
7
Use Complex
Systems
(section 1430)
GREG T. U
STATE OF WAS
RE GISTERED
ARCHITECT
Complex Systems
Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which
Complex Systems requirements are applicable to this project.
, t � . _ .. -41 r m lay q by 4 t v 1 , {
M e ch a ni Y cal ComplexSystems Chec k li st��r3<� O
2006 Washington State Nonresidential Energy Code Compliance Forms Revised Juiy 2007
Project Address ONC - South Center Mall
Dat 4/16/2008
The following additional information is necessary to check a mechanical permit application for a complex
mechanical system for compliance with the mechanical requirements in the Washington State Nonresidential
Energy Code. Use the checklist as a reference for notes added to the mechanical drawings (see the MECH-
CHK checklist for additional system requirements). This information must be on the plans since this is the
official record of the permit. Having this information in separate specifications alone is NOT an acceptable
alternative.
For Building Department Use
Applicability
(yes, no. n.a.)
Code
Section
Component
Information Required
Location
on Plans
Building Department
Notes
ADDITIONAL CHECKLIST ITEMS FOR COMPLEX SYSTEMS ONLY
n.a.
1431.1
Field assem. sys.
Provide calculations
n.a.
1432.1
Setback & shut -off
Indicate separate systems or show isolation devices on plans
n.a.
1432.2.1
Air system reset
Indicate automatic reset
n . a .
1432.2.2
Hydronic System
Indicate automatic reset, cooling tower, & heat pump loop
valves
n . a .
1433
Air Economizer
Indicate economizer on equipment schedule or provide
calculations to justify exemption and demonstrate 10% higher
efficiency for equipment with out economizer.
n.a.
1433
Water Economizer
Indicate water economizer and provide calculations if 1433
Exception 2 is utilized
n.a.
1434
Separate air sys.
Indicate separate systems on plans
n.a.
1435
Simul. htg. & clg.
Indicate that simultaneous heating and cooling is prohibited.
unless use of exception is justified
n.a.
1436
Heat recovery
Indicate heat recovery on plans; complete and attach heat
recovery calculations
n . a .
1437
Elec. motor effic.
MECH -MOT or Equip. Schedule with hp, rpm, efficiency
n. a .
1438
Variable flow sys.
Indicate variable flow on fan and pump schedules
n . a .
1439.1
Kitchen Hoods
Indicate uncooled and unheated make -up air
n.a.
1439.2
Fume Hoods
Indicate VAV, unheated / uncooled or heat rec. makeup
no is circled Tor any question, provide explanation:
Decision Flowchart
Start Here
-
Section 1411 1 Gas /Oil Furnace
Equipment Efficiency _ input 2 225,000
Shall Meet Tables a�tuh� or Gas /Ojl
14.1A through t4-1G blip Heater?
Yes
1411 1 Intermittent
• Ignition Device &
Power Venting or
Damper. If input >
' 225.000 Blurt then
1412.6 Modulating or
Staged Combustion
Controls Required
2006 Washington State Nonresidential Energy Code Compliance Form
Use this flowchart to determine how the requirements of the Complex Systems Opt o pply
KK
to the project. Refer to the indicated Code sections for more complete informa_ Nth
requirements. 1
8192
REGISTERED
ARCHITECT
Any Fuel Furnace
input 2 225,000,
Btuh7
Yes
1411.1 0.75%
Maximum Jacket
Loss
/N. / N
kieltlAssembled ' Air System
r� Equipment? �Noi —►� Serving Multiple ;>- or
\.. Zones?
Yes Yes
Section 1431.1
Calculations of Total
On -Site Energy Input
I & Ouput Required
•
(continued on back) ,
GREG T
STATE OF
Capac '
30
Yes
T -_....
• Section 1432 2.2 Hot
Section 1432.2 1 Water Supply
Supply Air Reset - - - -- ' Temperature Reset
Controls Required Required
No
Open Motors
Closed Motors
3,600
1,800
1,200
3,600
1,800
1,200
Efficiency ( %)
Efficiency ( %)
-
82.5
80.0
75.5
82.5
80.0
82.5
84.0
84.0
82.5
84.0
85.5
84.0
84.0
85.5
84.0
84.0
86.5
84.0
86.5
86.5
85.5
87.5
87.5
85.5
87.5
87.5
87.5
87.5
87.5
87.5
88.5
88.5
88.5
89.5
89.5
88.5
89,5
90.2
89.5
89.5
89.5
89.5
91.0
90.2
90.2
91.0
90.2
90.2
91.0
91.0
90.2
91.0
90.2
91.0
91.7
91.7
91.0
92.4
91.7
91.0
• 92.4
92.4
91.0
92.4
91.7
91.7
93.0
93.0
91.7
93.0
93.0
92.4
93.0
93.0
92.4
93.0
93.0
93.0
93.6
93.6
93.0
93.6
93.6
93.0
94.1
93.6
93.0
94.1
93.6
93.0
94.1
94.1
93.6
94.5
94.1
93.6
94.5
94.1
94.5
94.5
94.1
93.6
95.0
94.5
94.5
95.0
95.0
94.5
95.0
94.5
95.0
95.0
95.0
2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007
Project Address
Complete the following for all design A & B squirrel -cage, T -frame induction permanently wired
polyphase motors from 1 hp to 200 hp having synchronous speeds of 3600, 1800 or 1200 rpm
(unless one of the exceptions below applies).
Motor
No or
Location
Minimum Nominal Full -Load Efficienc
Synchronous
Speed (RPM)
HP
1.0
1.5
2.0
3.0
5.0
7.5
10
15
20
25
30
40
50
60
75
100
125
150
200
HP
2006 Washington State Nonresidential Energy Code Compliance Form
GNC - South Center Mall
Type
(open /closed)
Description of Application or Use
All motors are 1/3 HP or smaller
Date
Synch.
Speed
4/16/2008
For Building Department Use
GREG T. SI IUE
STATE OF WASH IN
Min.Nom.
Full load
Efficiency
Exceptions:
1. Motors in systems designed to use more
than one speed of a multi -speed motor.
2. Motors already included in the efficiency
requirements for HVAC equipment (Tables 14-
1A or 14-1B) .
3. Motors that are an integral part (i e. not
easily removed and replaced) of specialized
process equipment (i.e. equipment which
requires a special motor, such as an explosion -
proof motor).
4. Motors integral to a listed piece of
equipment for which no qualifying motor has
been approved (i.e. if the only U.L. listing for the
equipment is with a less- efficient motor and
there is no energy- efficient motor option).
For motors claiming an exception, list matt
and note which exception applies.
8492
REGISTERED
ARCHITECT
. Pns Checklist : a 4
M l Permit la
echanica :. �MECH r CH K
2006 Washington State Nonresidential Energy Code Compliance Forms Revised July
2007
Project Address GNC - South Center Mall
Dat 4/16/2008
The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the
Washington State Nonresidential Energy Code.
Applicability
(yes, no, n.a.)
Code
Section
Component
Information Required
Location
on Plans
Building Department
Notes
HVAC REQUIREMENTS (Sections 1401 -1424)
1411
Equipment performance
yes
1411.4
Pkg. elec. htg.& clg.
List heat pumps on schedule
Ml
yes
1411.1
Minimum efficiency
Equipment schedule with type, capacity, efficiency
Ml
n.a.
1411.1
Combustion htg.
Indicate intermittent ignition, flue /draft damper & jacket loss
1412
HVAC controls
yes
1412.1
Temperature zones
Indicate locations on plans
Ml
n. a.
1412.2
Deadband control
Indicate 5 degree deadband minimum
n.a.
1412.3
Humidity control
Indicate humidistat
yes
1412.4
Automatic setback
Indicate thermostat with night setback and 7 diff. day types
Ml
n.a.
1412.4.1
Dampers
Indicate damper location and auto. controls & max. leakage
n . a .
1412.4.2
Optimum Start
Indicate optimum start controls
yes
1412.5
Heat pump control
Indicate microprocessor on thermostat schedule
Ml
n.a.
1412.6
Combustion htg.
Indicate modulating or staged control
yes
1412.7
Balancing
Indicate balancing features on plans
Ml
1412.8
Ventilation Control
Indicate demand control ventilation for high- occupancy areas
n.a.
1422
Thermostat interlock
Indicate thermostat interlock on plans
n . a .
1423
Economizers
Equipment schedule
1413
Air economizers
n.a.
1413.1
Air Econo Operation
Indicate 100% capability on schedule
n.a.
1413.1
Wtr Econo Operation
Indicate 100% capacity at 45 degF db & 40 deg F wb
n.a.
1413.2
Water Econo Doc
Indicate clg load & water econoe & clg tower performance
n . a .
1413.3
Integrated operation
Indicate capability for partial cooling
n.a.
1413.4
Humidification Indicate direct evap or fog atomization w/ air economizer
1414
Ducting systems
yes
1414.1
Duct sealing
Indicate sealing necessary
M2
yes
1414.2
Duct insulation
Indicate R -value of insulation on duct
M2
yes
1415.1
Piping insulation
Indicate R -value of insulation on piping
M2
1416
Completion Requirements
n.a.
1416.2.1
Commissioning
Provide commissioning plan
n.a.
1416.2.2 -3
Sys.Bal & Func,Test
Indicate air and water system balancing & functional testing
n.a.
1416.2.4
Commissioning
Indicate O &M manuals, record drawings, staff training
n.a.
1416.2.5
Comm. Report
Indicate requirements for prelim. & final commissioning report
n.a.
1434
Separate air sys.
Indicate separate systems on plans
yes
Mechanical
Summary Form
Completed and attached. Equipment schedule with types,
input/output, efficiency, cfm, hp, economizer
SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) °
1440
, .�`
Service water htg. t
n.a.
1441
Elec. water heater
Indicate R -10 insulation under tank :
92
CGI£TEP D
Rr,,Hi>"ECT
n.a.
1442
Shut -off controls
Indicate automatic shut -off
n.a.
1443
Pipe Insulation
Indicate R -value of insulation on piping '
n . a .
1452
Heat Pump COP
Indicate minimum COP of 4.0
n . a.
1452
Heater Efficiency
Indicate pool heater efficiency
Gc EE
TOTE OF
T. SI
'� �
n.a.
1453
Pool heater controls
Indicate switch and 65 degree control
.IP�H
n.a.
• 1454
Pool covers
Indicate vapor retardant cover
'�"
11111,
n . a . 1454
Pools 90+ degrees Indicate R -12 pool cover
2006 Washington State Nonresidential Energy Code Compliance Form
no is circled for any question, provi exp
ACTIVITY NUMBER: M08 -111 DATE: 04 -22 -08
PROJECT NAME: GENERAL NUTRITION CORP
SITE ADDRESS: 978 SOUTHCENTER MALL
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # After Permit Issued
DEPARTMENTS:
Complete
Public Works
Comments:
TUES/THURS ROUTING:
Please Route
Documents/routing slip.doc
2 -28 -02
PLAN ' "VI iiiaffING SLIP
REVIEWER'S INITIALS:
Ell ,vu 1f O
Fire Prevention
Structural
APPROVALS OR CORRECTIONS:
Approved n Approved with Conditions
Notation:
REVIEWER'S INITIALS:
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 04 -24 -08
Incomplete
Structural Review Required
DATE:
DATE:
Planning Division
❑ Permit Coordinator
Not Applicable
No further Review Required
6.
n
Permit Center Use Only
INCOMPLETE LETTER MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
LETTER OF COMPLETENESS MAILED:
DUE DATE: 055 -22 -08
Not Approved (attach comments) ❑
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
License Information
License
SOUNDHA066BM
Licensee Name
SOUND HEATING & A/C INC
Licensee Type
CONSTRUCTION CONTRACTOR
UBI
601479795
Ind. Ins. Account Id
57759001
Business Type
CORPORATION
Address 1
5526 184TH STREET E
Address 2
City
PUYALLUP
County
PIERCE
State
WA
Zip
98375
Phone
2538753350
Status
ACTIVE
Specialty 1
HTGNENT /AIR CONDITIONING
Specialty 2
UNUSED
Effective Date
1/14/1994
Expiration Date
8/15/2009
Suspend Date
Separation Date
Parent Company
Previous License
SOUNDHCI 12N2
Next License
Associated License
Bond Information
Bond
Bond
Company
Name
Bond
Account
Number
Effective
Date
Expiration
Date
Cancel
Date
Impaired
Date
Bond
Amount
Received
Date
#5
CBIC
SC2727
08/03/2001
Until
Cancelled
$6,000.00
07/10/2001
#4
CBIC
SC2727
08/14/1999
08/03/2001
$4,000.00
Business Owner Information
Name
Role
Effective Date
Expiration Date
HOOD, CURTIS C
01/01/1980
HOOD, RANDY A
01/01/1980
Look Up a Contractor, Electrician or Plumber License Detail
Washington State Depaltrnent of Labor and Industries
General /Specialty Contractor
A business registered as a construction contractor with L &I to perform
construction work within the scope of its specialty. A General or Specialty
construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Page 1 of 2
https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= SOUNDHA066BM 07/08/2008
• 4 .III07:f3 •.
EXISTING TO I LET EXHAUST FAN
TO REMAIN. G.G. SHALL CLEAN
4 VERIFY UNIT IS IN GOOD
WORKING GONDITION.
„.e.[i<1
61=1RINKLEIR WORK
I. THE GENERAL CONTRACTOR SHALL EMPLOY A CERTIFIED SPRINKLER CONTRACTOR
APPROVED BY THE LANDLORD TO DESIGN $ INSTALL HEADS AS REQUIRED BY NEW LAYOUT
IN ACCORDANCE W/ NFPA 13, LIFE SAFETY 101 ALL APPLICABLE LOCAL GODES, INCLUDING
MALL REQUIREMENTS 4 INSURANCE CARRIER.
2. THE SPRINKLER CONTRACTOR SHALL PREPARE A SET OF SHOP DRAWINGS FOR REVIEW
BY THE CITY, OWNER AND L.L.'S INSURANCE CARRIER PRIOR TO BEGINNING ANY WORK
AS REQU I RED BY THE G I TY $ LANDLORD. HYDRAULIC CALCULATIONS AS REQUIRED.
3. ALL SPRINKLER HEADS SHALL BE QUICK RESPONSE TYPE HEADS.
4. THE FIRE PROTECTION SPRINKLER SYSTEM SHALL BE DESIGNED FOR ORDINARY GROUP 2
HAZARDS, NOT LESS THAN 0.20 GPM PER SQUARE FOOT OVER THE MOST REMOTE
2,500 SQUARE FOOT AREA.
5. ALL PRODUCTS SHALL BE F.M. APPROVED.
X�l
Q
10 GFM
100 GFM
Cf)co 0
E--10'(c,'
<
H= co
xo
z0 22
a
r
Z
N � a
r ina�
8 492
�T TCru
q'1 �
D
STETL0
ARC; i1T oT
fL
0
H
0
Z
T
0
1
0_
0_
F-
0
uJ
C
J
-� co
Q 00
�
W <
U 12 W
w�
D
L D
a) 1
Store No. 5288
Drawn by:
MWS
Checked By:
RR
Date:
6/7/2007
Date:
DATE CHECKED
Drawing Name:
05288,DWG
PROVIDE NEW LIGHT -STAT MODEL #TMDABU
THERMOSTAT. MOUNT @48" A.F.F.
350
V
GFM
SCALE: I/4" = I -O"
-G!
400
GFM
A
MECHANICAL PLAN
;6trylh�ytl.- 1 m4Yd,'ibl."v.� 141,51Si13PY4;...
BYBTEM V C (New)
CONTRACTOR SHALL REPLACE THE EXISTING SPLIT SYSTEM H/ A NEW UNIT
AS SPECIFIED. RE -USE THE EXISTING HANGERS $ ROOF MOUNTING IF POSSIBLE,
FIELD COORD INATE PRIOR TO SUBMITTING A BID. PROVIDE TRANSITION DUCT
AS REQUIRED FOR NEW UNIT. DO NOT RE -USE REFRIGERATION LINES, PROVIDE
ALL NEW REFRIGERATION LINES. RE-USE EXISTING CONDENSATE DRAIN $
SECONDARY DRAIN LINE ONLY IF THEY ARE GLEANED OUT TO A LIKE -NEW
CONDITION.
CONDENSING UNIT: CARRIE
GONDENSI
V
FAN GOIL: CARRIER #FX4A N- 036 -008 HORIZONTAL FAN GO L UNIT
1200 GFM @ • . , 8" E.S.P. 1 /3 HP MOTOR
@ 208V/I1) WITH 8 KW ELECTRIC HEAT STRIP.
3 ROW, 14 FINS/ INCH.
APPROXIMATE WEIGHT = 183 LBS.
HEATER #KFCEH250IGO& @ 208V/1
UNIT SHALL BE PROVIDED WITH SINGLE POINT
ELECTRICAL GONNE
• A
35A/3P BF
MINIMUM EER = 13.0•
THE CONTRACTOR SHALL COORDINATE THE MATCH SPLIT SYSTEM 4 VERIFY
WITH THE MANUFACTURER THE MINIMUM EERRATING IS 13.0 PRIOR TO ORDERING
ANY SEAR.
0 6 AIR COOLED HEAT PUM
MOUNTED ON EXISTING ROOF SUP
E 4 3/4" O.D. VAPOR LINE
HEIGHT = 208 LBS.
36,000 BTUH
208V /I 4).
SEMI - RECESSED SPRINKLER HEAD
TYPICAL FOR LAY -IN GEILINO.
REFER TO "SPRINKLER WORK ".
400
CONGEALED TYPE SPRINKLER HEAD
TYPICAL FOR ALL HARD CEILING
LOCATIONS. REFER TO "SPRINKLER
WORK ".
TION. 50A/20.5V/IP BREAKER.
FM
LI
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAY - 1 2000
B ' ILDI
Of Tukwila
DPT {SIB' G
i 6EiARATE PERMIT
REQUIRED FOR:
0 Mechanical
Electrical
IV
Vi Gas Piping
City of Tukwila
B UILDING DIVISION
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submit
and may include additional plan review fees.
FILE p
� - 1�
Permit e
r'iar review approval is subject to errors and orrissions.
�.+� �` Ytl 1 �y /M1 a}�7 documents p`} aro doffs net. authorize �prty . t•-• COfl traction doc men s a
�` (fl / •d.df► ter? code or ort ':nr "� �
C i G �
"i f Cvtl5 L;; Cr; ditiO 't3
RECEIVED
APR 2 2 2008 Drawing No.
PERMIT CENTER
1i
SPIN -IN FITTING W/ FULL QUADRANT
1
DEvICE L
MECHpAINIC41. WK
DAMPER AND SCOOP.
IIMEWAR
r__,
24 X 24 LAY -IN 4 -WAY SUPPLY AIR DIFFUSER
W/ ROUND NECK AND OPPOSED BLADE DAMPER.
TITUS MODEL #TMS, FRAME TYPE 3, 24 X 24 FACE.
I.
THE MECHANICAL CONTRACTOR SHALL BECOME FAMILIAR WITH THE PROJECT PRIOR
TO SUBMITTING A BID. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION
OF THE GNG PROJECT MANAGER PRIOR TO BIDDING.
2.
M.G. SHALL CHECK THE EXISTINSSUPPLY, RETURN AND EXHAUST DUET FOR ANY LEAKS
ROUND METAL DUGT
(LENGTH
i__‘
24 II X 24" RETURN AIR GRILLE. I X I" X I
AND SHALL REPAIR SAME. RE -USE EXISTING DUCT AND TAPS WHERE POSSIBLE.
AS REQUIRED)
CUBE GORE CONSTRUCTION (EGG CRATE).
TITUS MODEL #5OF, TYPE 3.
3.
M.G. SHALL PROVIDE ALL NEW AIR DEVICES (BOTH SUPPLY 4 RETURN) AS SCHEDULED.
ROUND FLEX
4.
AT THE COMPLETION OF THE PROJECT THE MECHANICAL CONTRACTOR SHALL INSTALL
DUCT
(NOT TO EXCEED 5' LENGTH)
A NEH, GLEAN SET OF FILTERS.
5.
G.G. SHALL VERIFY THE EXISTING FIRE/ SMOKE ALARM SYSTEM IS IN GOOD WORKING
SUPPLY AIR DIFFUSER W/ ROUND NECK
GOND ITION AND MEETS ALL CUR: ENT LANDLORD AND LOCAL CODE REQUIREMENTS
AND OPPOSED BLADE DAMPER.
OR SHALL MOD IFY AS REQUIRED.
6.
M.G. SHALL LOCATE THERMOSTAT AS SHOWN ON THE PLANS AND MOUNT ® 48" A.F.F.
BL1PPLX IIIIR DIPPLZER T 11.
I.
M.G. SHALL VERIFY THE EXISTING TOILET EXHAUST SYSTEM IS IN GOOD WORKING ORDER
NO SCALE
AND IS GLEAN IN A LIKE -NEW CONDITION OR SHALL REPAIR TO SAME.
• 4 .III07:f3 •.
EXISTING TO I LET EXHAUST FAN
TO REMAIN. G.G. SHALL CLEAN
4 VERIFY UNIT IS IN GOOD
WORKING GONDITION.
„.e.[i<1
61=1RINKLEIR WORK
I. THE GENERAL CONTRACTOR SHALL EMPLOY A CERTIFIED SPRINKLER CONTRACTOR
APPROVED BY THE LANDLORD TO DESIGN $ INSTALL HEADS AS REQUIRED BY NEW LAYOUT
IN ACCORDANCE W/ NFPA 13, LIFE SAFETY 101 ALL APPLICABLE LOCAL GODES, INCLUDING
MALL REQUIREMENTS 4 INSURANCE CARRIER.
2. THE SPRINKLER CONTRACTOR SHALL PREPARE A SET OF SHOP DRAWINGS FOR REVIEW
BY THE CITY, OWNER AND L.L.'S INSURANCE CARRIER PRIOR TO BEGINNING ANY WORK
AS REQU I RED BY THE G I TY $ LANDLORD. HYDRAULIC CALCULATIONS AS REQUIRED.
3. ALL SPRINKLER HEADS SHALL BE QUICK RESPONSE TYPE HEADS.
4. THE FIRE PROTECTION SPRINKLER SYSTEM SHALL BE DESIGNED FOR ORDINARY GROUP 2
HAZARDS, NOT LESS THAN 0.20 GPM PER SQUARE FOOT OVER THE MOST REMOTE
2,500 SQUARE FOOT AREA.
5. ALL PRODUCTS SHALL BE F.M. APPROVED.
X�l
Q
10 GFM
100 GFM
Cf)co 0
E--10'(c,'
<
H= co
xo
z0 22
a
r
Z
N � a
r ina�
8 492
�T TCru
q'1 �
D
STETL0
ARC; i1T oT
fL
0
H
0
Z
T
0
1
0_
0_
F-
0
uJ
C
J
-� co
Q 00
�
W <
U 12 W
w�
D
L D
a) 1
Store No. 5288
Drawn by:
MWS
Checked By:
RR
Date:
6/7/2007
Date:
DATE CHECKED
Drawing Name:
05288,DWG
PROVIDE NEW LIGHT -STAT MODEL #TMDABU
THERMOSTAT. MOUNT @48" A.F.F.
350
V
GFM
SCALE: I/4" = I -O"
-G!
400
GFM
A
MECHANICAL PLAN
;6trylh�ytl.- 1 m4Yd,'ibl."v.� 141,51Si13PY4;...
BYBTEM V C (New)
CONTRACTOR SHALL REPLACE THE EXISTING SPLIT SYSTEM H/ A NEW UNIT
AS SPECIFIED. RE -USE THE EXISTING HANGERS $ ROOF MOUNTING IF POSSIBLE,
FIELD COORD INATE PRIOR TO SUBMITTING A BID. PROVIDE TRANSITION DUCT
AS REQUIRED FOR NEW UNIT. DO NOT RE -USE REFRIGERATION LINES, PROVIDE
ALL NEW REFRIGERATION LINES. RE-USE EXISTING CONDENSATE DRAIN $
SECONDARY DRAIN LINE ONLY IF THEY ARE GLEANED OUT TO A LIKE -NEW
CONDITION.
CONDENSING UNIT: CARRIE
GONDENSI
V
FAN GOIL: CARRIER #FX4A N- 036 -008 HORIZONTAL FAN GO L UNIT
1200 GFM @ • . , 8" E.S.P. 1 /3 HP MOTOR
@ 208V/I1) WITH 8 KW ELECTRIC HEAT STRIP.
3 ROW, 14 FINS/ INCH.
APPROXIMATE WEIGHT = 183 LBS.
HEATER #KFCEH250IGO& @ 208V/1
UNIT SHALL BE PROVIDED WITH SINGLE POINT
ELECTRICAL GONNE
• A
35A/3P BF
MINIMUM EER = 13.0•
THE CONTRACTOR SHALL COORDINATE THE MATCH SPLIT SYSTEM 4 VERIFY
WITH THE MANUFACTURER THE MINIMUM EERRATING IS 13.0 PRIOR TO ORDERING
ANY SEAR.
0 6 AIR COOLED HEAT PUM
MOUNTED ON EXISTING ROOF SUP
E 4 3/4" O.D. VAPOR LINE
HEIGHT = 208 LBS.
36,000 BTUH
208V /I 4).
SEMI - RECESSED SPRINKLER HEAD
TYPICAL FOR LAY -IN GEILINO.
REFER TO "SPRINKLER WORK ".
400
CONGEALED TYPE SPRINKLER HEAD
TYPICAL FOR ALL HARD CEILING
LOCATIONS. REFER TO "SPRINKLER
WORK ".
TION. 50A/20.5V/IP BREAKER.
FM
LI
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAY - 1 2000
B ' ILDI
Of Tukwila
DPT {SIB' G
i 6EiARATE PERMIT
REQUIRED FOR:
0 Mechanical
Electrical
IV
Vi Gas Piping
City of Tukwila
B UILDING DIVISION
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submit
and may include additional plan review fees.
FILE p
� - 1�
Permit e
r'iar review approval is subject to errors and orrissions.
�.+� �` Ytl 1 �y /M1 a}�7 documents p`} aro doffs net. authorize �prty . t•-• COfl traction doc men s a
�` (fl / •d.df► ter? code or ort ':nr "� �
C i G �
"i f Cvtl5 L;; Cr; ditiO 't3
RECEIVED
APR 2 2 2008 Drawing No.
PERMIT CENTER
1i
aiii?Mt . ilatt BN '@iGk' +4 .teS5ie' it
GENERAL
A. THE GENERAL CONDITIONS OF THE GENERAL SPECIFICATIONS, ALONG
WITH ALL APPLICABLE INSTRUCTIONS TO BIDDERS SHALL FORM A PART
OF THIS SECTION OF THE SPECIFICATIONS.
B. REFERENCE 15 MADE TO REQUISITES FOR BIDDERS AND CONTRACTORS
UNDER OTHER SECTIONS OF THESE SPECIFICATIONS, WHICH SHALL
BE CONSIDERED BINDING, UNLESS OTHERWISE NOTED UNDER THIS
SECTION.
SCOPE
EACH CONTRACTOR SHALL THOROUGHLY ACQUAINT HIMSELF WITH THE CON -
STRUCTION DETAILS, BOTH AS ON TENANT CONSTRUCTION DRAWINGS AND
LANDLORD'S AS REFERRED TO, BEFORE SUBMITTING HIS BID AS NO ALLOW-
ANCES WILL BE MADE BECAUSE OF THE CONTRACTORS UNFAMILIARITY WITH
THESE DETAILS. ALL PERFORMANCE OF CONSTRUCTION SHALL BE AS
REQUIRED BY THE PAGE OF THE GENERAL CONSTRUCTION.
INSPECTION OF SITE
ALL PROPOSALS SHALL PRECLUDE THAT CONTRACTOR IS FAMILIAR WITH
JOBSITE CONDITIONS AND UTILITY LOCATIONS AND THE LACK OF SPECIFIC
INFORMATION ON THE DRAWINGS SHALL NOT RELIEVE THE CONTRACTOR OF ANY
RESPONSIBILITY.
PERMITS
ALL PERMITS AND LICENSES NECESSARY FOR THE PROPER EXECUTION OF THE
WORK SHALL BE SECURED AND PAID FOR BY THE SUBCONTRACTOR INVOLVED.
CODE REQUIREMENTS
ALL WORK UNDER THIS CONTRACT SHALL COMPLY WITH THE PROVISIONS OF
THE SPECIFICATIONS, DRAWINGS OR AS DIRECTED BY THE OWNER, AND
SHALL SATISFY ALL APPLICABLE GODES, ORDINANCES, OR REGULATIONS OF
THE GOVERNING BODIES, WHETHER SO SHOWN OR NOT, AND ALL MODIFICA-
TIONS REQUIRED BY SUCH AUTHORITIES SHALL BE MADE BY THE CONTRACTOR
WITHOUT ANY ADDITIONAL COST TO THE OWNER.
MATERIALS AND WORKMANSHIP
A. ALL MANUFACTURED ARTICLES, MATERIALS, AND EQUIPMENT SHALL BE
APPLIED AS RECOMMENDED BY THE MANUFACTURERS, AND UNLESS OTHER-
WISE SPECIFIED SHALL BE NEW, AND FREE FROM ANY DEFECTS. ALL
LIKE MATERIALS USED SHALL BE OF THE SAME MANUFACTURE AND
QUALITY UNLESS OTHERWISE SPECIFIED.
B. ALL WORK UNDER THIS CONTRACT SHALL BE PERFORMED BY COMPETENT
WORKMEN AND EXECUTED IN A NEAT AND WORKMANLIKE MANNER. WORK
SHALL BE PROPERLY PROTECTED DURING CONSTRUCTION, AND ON COM-
PLETION, THE INSTALLATION SHALL BE THOROUGHLY GLEANED AND ALL
DEBRIS PRESENT AS A RESULT OF THIS CONTRACT SHALL BE REMOVED
FROM THE PREMISES.
GODES AND REGULATIONS
EACH SUBCONTRACTOR SHALL COMPLY WITH ALL LAWS, ORDINANCES, RULES
AND REGULATIONS BEARING ON THE CONDUCT OF THE WORK AS DRAWN OR
SPECIFIED. IF A SUBCONTRACTOR OBSERVES THAT THE DRAWINGS AND
SPECIFICATIONS ARE AT A VARIANCE, HE SHALL PROMPTLY NOTIFY THE
GENERAL CONTRACTOR AND THE TENANT IN WRITING. IF ANY SUBCONTRACTOR
PERFORMS ANY WORK KNOWING IT TO BE CONTRARY TO LAWS, ORDINANCES,
RULES AND REGULATIONS AND WITHOUT GIVING SUCH NOTICE, THE SUBCON-
TRACTOR SHALL BEAR ALL COSTS ARISING THEREFROM.
PROTECTION OF WORK AND PROPERTY
A. EACH SUBCONTRACTOR SHALL CONTINUOUSLY MAINTAIN ADEQUATE PRO-
TECTION OF ALL HIS WORK FROM DAMAGE AND SHALL PROTECT THE
OWNER'S PROPERTY FROM INJURY OR LOSS ARISING FROM HIS WORK.
HE SHALL MAKE GOOD ANY SUCH DAMAGE, INJURY, OR LOSS, EXCEPT
SUCH AS MAY BE DIRECTLY DUE TO CAUSES BEYOND HIS CONTROL AND
NOT TO HIS FAULT OR NEGLIGENCE. HE SHALL ADEQUATELY PROTECT
ADJACENT PROPERTY AS WELL.
B. EACH SUBCONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS FOR
THE SAFETY OF THEIR EMPLOYEES ON THE WORK AND SHALL COMPLY
WITH ALL PROVISIONS OF FEDERAL, STATE AND LOCAL BUILDING
CODES AND SAFETY LAWS TO PREVENT ACCIDENTS OR INJURY TO
PERSONA ON OR ADJACENT TO THE PREMISES WHERE THE WORK IS
BEING PERFORMED. EACH SUBCONTRACTOR SHALL MAINTAIN ALL INSUR-
ANCE REQUIRED TO PROTECT HIMSELF, OWNER AND TENANT FOR THE
DURATION OF THE WORK AGAINST PROPERTY DAMAGE AND PUBLIC
LIABILITY.
CHANGES IN THE WORK
THE TENANT, WITHOUT INVALIDATING THE CONTRACT, MAY ORDER EXTRA WORK
OR MAKE CHANGES BY ALTERING, ADDING TO OR DEDUCTING FROM THE WORK,
THE CONTRACT SUM BEING ADJUSTED ACCORDINGLY.
COOPERATION
ALL WORK UNDER THESE SPECIFICATIONS SHALL BE ACCOMPLISHED IN CON-
JUNCTION WITH OTHER CONTRACTORS AND TRADES OF THIS PROJECT IN A
MANNER WHICH WILL ALLOW EACH CONTRACTOR AND TRADE ADEQUATE TIME AT
THE PROPER STAGE OF CONSTRUCTION TO FULFILL HIS CONTRACTS. REFER-
ENCE SHALL BE MADE TO THE OWNER FOR INSTRUCTIONS SHOULD ANY
QUESTIONS ARISE BETWEEN TRADES AS TO THE PLACING OF LINES, DUCTS,
CONDUITS, FIXTURES, OR EQUIPMENT, OR SHOULD IT APPEAR DESIRABLE TO
REMOVE ANY GENERAL CONSTRUCTION WHICH WOULD AFFECT THE APPEARANCE
OF STRENGTH OF THE STRUCTURE.
SUBSTITUTION OF MATERIALS
MANUFACTURER'S NAMES ARE LISTED HEREIN TO ESTABLISH A STANDARD.
THE PRODUCTS OF OTHER MANUFACTURERS WILL BE ACCEPTABLE, IF IN THE
OPINION OF THE TENANT, THE SUBSTITUTE MATERIAL IS OF A QUALITY AS
GOOD OR BETTER THAN THE MATERIAL SPECIFIED, AND HILL SERVE WITH
EQUAL EFFICIENCY AND DEPENDABILITY, THE PURPOSE FOR WHICH THE
ITEMS SPECIFIED WERE INTENDED.
SHOP DRAWINGS
SHOP DRAWINGS AND CATALOGUE DATA ON ALL MAJOR ITEMS OF EQUIPMENT
AND SYSTEMS, AND SUCH OTHER ILLUSTRATIVE MATERIAL AS MAY BE
CONSIDERED NECESSARY BY THE TENANT, SHALL BE SUBMITTED BY THIS
CONTRACTOR IN ADEQUATE TIME TO PREVENT DELAY AND CHANGES DURING
CONSTRUCTION.
DRAWINGS AND SPECIFICATIONS
A. THE DRAWINGS SHOW DIAGRAMMATICALLY THE LOCATIONS OF THE
VARIOUS LINES, DUCTS, CONDUITS, FIXTURES, AND EQUIPMENT AND
THE METHOD OF CONNECTING AND CONTROLLING THEM. IT IS NOT
INTENDED TO SHOW EVERY CONNECTION IN DETAIL AND ALL FITTINGS
REQUIRED FOR A COMPLETE SYSTEM.
13. SHOULD ANY CHANGES BE DEEMED NECESSARY BY THE CONTRACTOR IN
ITEMS SHOWN ON CONTRACT DRAWINGS, THE SHOP DRAWINGS, DES-
CRIPTIONS, AND THE REASON FOR THE PROPOSED CHANGES SHALL BE
SUBMITTED TO THE OWNER FOR APPROVAL.
RESPONSIBILITY
A. THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR THE SATISFACTORY
AND COMPLETE EXECUTION OF ALL WORK INCLUDED IN HIS CONTRACT.
HE SHALL PRODUCE COMPLETE FINISHED OPERATING SYSTEMS AND PRO-
VIDE ALL INCIDENTAL ITEMS REQUIRED AS PART OF HIS WORK,
REGARDLESS OF WHETHER SUCH ITEM IS PARTICULARLY SPECIFIED OR
INDICATED.
B. CONTRACTOR SHALL SUPPLY TO LANDLORD AND TENANT A CERTIFIED
BALANCE REPORT AT COMPLETION OF PROJECT. THIS IS REQUIRED FOR
BOTH REMODELED AND NEW STORES.
HEATING, VENTILATING AND AIR CONDITIONING
GENERAL
A. THE WORK COVERED BY THIS SECTION OF THESE SPECIFICATIONS SHALL
BE ACCOMPLISHED IN ACCORDANCE WITH THE RESPECTIVE DRAWINGS,
INFORMATION, OR INSTRUCTIONS TO BIDDERS, AND THE GENERAL CON-
DITIONS, ADDENDA, OR DIRECTIVES WHI MAY BE ISSUED BY THE
OWNER, HEREWITH, OR OTHERWISE, SHALL BE COMPLIED WITH IN EVERY
RESPECT.
B. THE LISTING HEREIN OF AN ARTICLE OR MATERIAL, OPERATION OR
METHOD, REQUIRES THAT THE CONTRACTOR SHALL FURNISH AND INSTALL
EACH ITEM LISTED, UNLESS SPECIFICALLY NOTED TO THE CONTRARY.
THE CONTRACTOR SHALL PERFORM EACH OPERATION PRESCRIBED OR
LISTED ACCORD TO THE CONDITIONS STATED.
( ; A.' bti F2rsrira.f- 1�5•:.ir,�Eu�r < `t €�;7 iR'.0 *tua�e'7i'44LS+�r: �a�ea9s+.:ti/ayy°�eFar. slt +aY;K3tu;
EXAMINATION OF SITE
ALL CONTRACTORS SUBMITTING PROPOSALS FOR THIS WORK SHALL FIRST
EXAMINE THE 51TE AND ALL CONDITIONS THEREON AND /OR THEREIN. ALL
PROPOSALS SHALL TAKE INTO CONSIDERATION ALL SUCH CONDITIONS AS MAY
AFFECT THE WORK UNDER THIS CONTRACT.
SCOPE
FURNISH ALL MATERIALS, EQUIPMENT, AND LABOR NECESSARY FOR A COM-
PLETE FULLY OPERATIVE HEATING, VENTILATING, AND AIR CONDITIONING
SYSTEM EXCEPT AS SPECIFICALLY EXCLUDED BY THE DRAWINGS, AND /OR
TENANTS DIRECTIONS.
EQUIPMENT
A. AIR CONDITIONING UNITS - UNITS SHALL BE FACTORY ASSEMBLED AND
PRE - TESTED INCLUDING FANS, MOTORS, COILS, FILTERS, VARIABLES
PITCH DRIVES, ETC,. ALL UNITS SHALL BE EQUIPPED WITH AN ECONO-
MIZER PACKAGE AND RELIEF DAMPER. UNITS SHALL HAVE NET
CAPACITY RATINGS DETERMINED AT THE SPECIFIED DESIGN CONDI-
TIONS. THESE NET CAPACITY RATINGS SHALL BE DETERMINED BY
DEDUCTING FOR MOTOR HEAT. THE AIR CONDITIONING UNITS SUPPLIED
SHALL HAVE A TOTAL SYSTEM ENERGY RATIO (EER) OF NOT LESS THAN
- 15. THIS EER SHALL BE DETERMINED BY DIVIDING THE NET
CAPACITY AS DEFINED ABOVE BY THE TOTAL INPUT WATTAGE. THE
TOTAL INPUT WATTAGE IS TO INCLUDE THE WATTAGE OF ALL FAN
MOTORS AND ASSOCIATED EQUIPMENT. CONTRACTOR WILL FURNISH
VIBRATION ISOLATION AS REQUIRED AND RECOMMENDED BY EQUIPMENT
MANUFACTURER.
B. AIR COOLED CONDENSING UNITS - UNITS SHALL BE FACTORY ASSEMBLED
AND PRE- TESTED, AND WILL INCLUDE HEAVY GALVANIZED STEEL
HOUSING FINISHED WITH BAKED ENAMEL, AIR COOLED CONDENSERS WITH
COPPER TUBES AND ALUMINUM FINS, CONTROL PANEL, COMPRESSOR HIGH
AND LOW PRESSURE CUTOUTS, MUFFLERS, CRANKCASE HEATERS, LIQUID
RECEIVE, ETC. COMPRESSORS SHALL BE OF THE HERMETICALLY SEALED
OR SEMI- HERMETICALLY SEALED TYPE. (LOW AMBIENT CONTROL STD.)
G. CENTRAL STATION AIR HANDLING EQUIPMENT - (IF SCHEDULED ON
DRAWINGS) SHALL BE LOW TO MEDIUM PRESSURE SINGLE ZONE DRAW -
THRU UNITS EQUAL TO TRANE OR CARRIER. THEY SHALL BE COMPLETE
WITH COOLING AND /OR HEATING COILS AND ACCESSORIES AS SPECIFIED
ON THE PLANS.
RELIEF AIR FANS
I. GRAVITY RELIEF - EQUAL TO BREIDERT TYPE "RLO" WITH
INTEGRAL BACKDRAFT DAMPER AND INSECT SCREEN.
2. POWER RELIEF - EQUAL TO BREIDERT TYPE "LO -SET" SET
WITH MOTORIZED DAMPER AND INTEGRAL BAGKDRAFT DAMPER
AND INSECT SCREEN.
D. ELECTRIC STRIP HEATER - EACH STRIP HEATER SHALL BE CONSTRUCTED
TO SLIP INTO THE DUCT THROUGH A RECTANGULAR OPENING IN THE
SIDE. EACH STRIP HEATER SHALL BE FURNISHED COMPLETE WITH
BUILT -IN MAGNETIC CONTACTORS, AIR FLOW SWITCH, AND FACTORY
PREWIRED TO TERMINAL STRIPS FOR LINE AND CONTROL CONNECTIONS
IN THE FIELD. A THERMAL CUTOUT SHALL BE FURNISHED WITH EACH
STRIP HEATER TO PROTECT THE HEATER AGAINST AIR FAILURE. THE
COMPLETE HEATING UNIT SHALL BE LISTED BY UNDERWRITER'S
LABORATORIES, INC. COILS SHALL BE ARRANGER FOR MINIMUM TWO -
STAGE CONTROL IOKW AND ABOVE.
E. FILTERS - FILTERS SHALL BE OF THE THROW AWAY TYPE WHEREVER
POSSIBLE. IF FILTERS ARE OF NECESSITY THE PERMANENT TYPE,
THEN THEY MUST BE OF THE CLEANABLE, HIGH VELOCITY TYPE AND
SHALL BE AMERICAN AIR FILTERS, AIR MAYS, EVANS, OR APPROVED
EQUAL. FILTERS SHALL BE OF THE OPTIMUM THICKNESS AND DESIGN
FACE VELOCITY SHALL NOT EXCEED 550 FPM. INSTALLATION OF THE
AIR CONDITIONING UNIT SHALL BE SUCH SO AS TO NOT IMPEDE
ACCESS TO THE FILTERS. IF THE FILTERS ARE IN FRAME HOLDERS,
THEN SUCH HOLDERS SHALL BE PROVIDED WITH A LEFT HANDLE.
F. EXHAUST FANS
I. SHOW WINDOWS - EQUAL TO COOK GEM -N SERIES. NOTE THAT IN
ANY CASE, NO PLASTIC PARTS WILL BE ACCEPTABLE.
2. EXHAUST FAN /LIGHT COMBINATION BY E.G. SHALL BE NUTONE
#5663, 100 GEM; C 25 S.P. WITH 4" DI A. DUCT AND BACK -
DRAFT DAMPER I10/I/60, 13 AMP, 51 WATTS.
G. ALL SINGLE STAGE UNITS WILL BE EQUIPPED WITH DYNELGO MULTI -
STAT TMC2- PC -AVU THERMOSTAT. A DUAL STAGE UNIT WILL BE
EQUIPPED WITH A TANDEM DAY/NIGHT THERMOSTAT ARRANGEMENT.
DESIGN AND STANDARD CONDITIONS FOR THERMOSTAT OPERATION WILL
BE AS FOLLOWS:
COOLING: 70 F MINIMUM OCCUPIED COOLING TEMPERATURE
S5 F COOLING NIGHT SETBACK.
HEATING: 75 F MAXIMUM OCCUPIED HEATING TEMPERATURE
60 F HEATING NIGHT SETBACK.
H. THE HVAC SUBCONTRACTOR SHALL IDENTIFY ALL ROOF MOUNTED
HVAC EQUIPMENT AND APPARATUS WITH 2" HIGH PAINTED STENCILED
STORE NAME ON ALL SIDES OF EQUIPMENT.
DUCTWORK
A. SQUARE AND RECTANGULAR DUCTWORK SHALL BE CONSTRUCTED OF NEW
GALVANIZED PRIME GRADE SHEET STEEL OF THE FOLLOWING GAUGES:
DUCT SIZE
12" AND LESS
13" TO 30"
31" TO 54"
55" TO b4"
55" AND OVER
GAUGE
NO. 26 U.S. GAUGE
NO. 24 U.S. GAUGE
NO. 22 U.S. GAUGE
NO. 20 U.S. GAUGE
NO. IS U.5. GAUGE
B. SQUARE AND RECTANGULAR DUCTWORK SHALL BE CONSTRUCTED AS
FOLLOWS:
SIZE
I AND LESS
IS" TO 30"
31" TO 54"
METHOD
"S" AND DRIVE CLEATS
"L" STANDING SEAMS ON
3' -0" CENTERS
1 -1/4" STANDING SEAMS
ON 3' -0" CENTERS
ROUND DUCTWORK SHALL BE CONSTRUCTED OF NEW GALVANIZED PRIME
GRADE SHEET STEEL OF THE FOLLOWING GAUGES:
DUCT SIZE (DIAMETER)
S" AND LESS
1" TO 18"
11" TO 30"
DUCTS
24
22
20
FITTINGS
22
20
15
ALL 10 DEGREE ELBOWS FOR ROUND DUCTWORK SHALL BE FIVE (5)
PIECE. ALL LONGITUDINAL SEAMS SHALL BE FORMED BY PITTSBURGH
LOCKS. JOINTS SHALL BE SWAGGED WITH ONE -HALF INCH (I/2 ")
OVERLAP.
G. ALL SUPPLY AIR DUCTS (HEATING AND COOLING) AND RETURN AIR
DUCTS AND OUTSIDE AIR DUCTS SHALL BE GALVANIZED STEEL WITH
MINIMUM I" THICK INTERNAL ACOUSTICAL AND THERMAL INSULATION.
ALL EXHAUST AND RELIEF AIR DUCTS SHALL BE GALVANIZED STEEL.
D. CONTRACTOR WILL INSTALL INSECT SCREENS ON ALL DUCT OPENINGS
WHICH LEAD TO OR ARE OUTDOORS. INSECT SCREENS SHALL BE 10
GAUGE, ONE -HALF INCH (1/2") MESH IN REMOVABLE GALVANIZED
STEEL FRAMES.
E. ALL DUCTWORK SHALL BE DESIGNED IN ACCORDANCE WITH THE
PROCEDURES DESCRIBED IN THE AMERICAN SOCIETY OF HEATING
REFRIGERATION AND AIR CONDITIONING ENGINEERS GUIDE ( ASHRAE)
AND FABRICATED AND INSTALLED IN ACCORDANCE WITH THE LATEST
METHODS RECOMMENDED IN THE SHEETMETAL AND AIR CONDITIONING
CONTRACTORS NATIONAL ASSOCIATION (SMAGNA) LOW VELOCITY DUCT
MANUAL, LATEST EDITION.
HANGERS AND SUPPORTS
A. ALL HORIZONTAL DUCTS HAVING A DIMENSION OF 40 INCHES AND LESS
SHALL BE SUPPORTED BY MEANS OF BAND IRON HANGERS OF NO. IS
U.S. GAUGE ATTACHED TO THE DUCT BY MEANS OF RIVETS, SCREWS, OR
CLAMPS, AND FASTENED TO STRUCTURE ABOVE BY TOGGLE BOLTS OR
OTHER MEANS. EACH SECTION OF DUCTWORK SHALL HAVE AT LEAST ONE
PAIR OF SUPPORTS. VERTICAL DUCTS SHALL BE SUPPORTED WITH
I -1/4" x I -I/4" x I -1/4" ANGLES WHERE THEY PASS THROUGH THE
FLOOR LINES.
B. ALL HORIZONTAL DUCTS HAVING A DIMENSION OF 40 INCHES AND MORE
SHALL BE SUPPORTED BY MEANS OF ANGLE IRON TRAPEZE HANGERS.
EACH SECTION OF DUCTWORK SHALL HAVE AT LEAST ONE PAIR OF
SUPPORTS.
FLASHING
A. CONTRACTOR WILL PROVIDE WATER TIGHT 24 GA. SHEET METAL
FLASHINGS AT ALL EXTERIOR HALLS AND ROOF PENETRATIONS.
B. ALL GUTTING OF ROOF OPENINGS, SUPPORTS FOR ROOF OPENINGS,
PITCH PANS, ROOF CURBS, FLASHINGS, COUNTER FLASHINGS, REPAIR
TO ROOF, ETC,. ASSOCIATED WITH HVAC SUBCONTRACTOR SHALL BE
THE RESPONSIBILITY AND PART OF THE CONTRACT HVAC SUB-
CONTRACTOR. HE SHALL EMPLOY THE LANDLORD'S ROOFERS FOR
THIS WORK SO AS TO MAINTAIN THE ROOF BOND.
DAMPERS
A. SPLITTER DAMPERS SHALL BE FABRICATED OF SHEET STEEL NOT LESS
THAN NO. 16 U.S. GAUGE WITH THE LEADING EDGE HEMMED. EAGd
DAMPER SHALL BE LARGE ENOUGH TO COVER THE SMALLER OF THE TWO
OPENINGS IT CONTROLS. DAMPERS SHALL BE CONTROLLED AS FOLLOWS:
EXPOSED OR ACCESSIBLE DUCTWORK - LOCKING QUADRANTS EQUAL TO
YOUNG REGULATOR NO. I WITH DAMPER ROD END BEARINGS ON OPPOSITE
END.
CONGEALED DUCTWORK - LOCKING QUADRANT EQUAL TO YOUNG REGULATOR
NO. 315 (CHROMIUM PLATED WITH DAMPER ROD END BEARINGS ON BOTH
ENDS).
B. VOLUME DAMPERS SHALL BE OF THE OPPOSED INTERLOCKING TYPE AS
MANUFACTURED BY AMERICAN FOUNDRY AND FURNACES GO. (AFFGO) OR
EQUAL. BLADES SHALL BE OF NO. 16 GAUGE SHEET METAL AND SHALL
NOT EXCEED 45" IN LENGTH OR 12" IN WIDTH. BLADES SHALL BE ON
ONE -HALF INCH (I/2 ") DIAMETER RUSTPROOF AXLE. BEARINGS SHALL
BE OF THE SELF - LUBRICATING FERRULE TYPE.
G. JOB FABRICATED TURNING VANES SHALL BE ACCEPTABLE IN SQUARE
ELBOWS. PROVIDE AND INSTALL BARBER- GOLMAN AIRTURNS OR EQUAL.
TURNING VANES SHALL BE OF THE SAME GAUGE METAL AS THE DUCT IN
WHICH THEY ARE INSTALLED. RADIUS ELB01 SHALL HAVE A CENTER-
LINE RADIUS OF ONE AND ONE -HALF (I -1/2) TIMES THE DUCT WIDTH.
FIBROUS GLASS DUCT SYSTEMS OPTION
AT HIS OPTION, THE CONTRACTOR MAY FURNISH OVENS- CORNING 500FR OR
SOOFRK OR EQUAL FOR ALL SUPPLY AND RETURN DUCTWORK WHERE THE AIR
VELOCITY IS UNDER 2400 FPM, STATIC, PRESSURE IS 2" OR LESS AND THE
AIR TEMPERATURE IS 250 F LESS. SYSTEM SHALL BE FABRICATED,
REINFORCED AND INSTALLED ACCORDING TO THE "SMAGNA" PUBLICATION -
FIBROUS GLASS DUCT CONSTRUCTION STANDARDS, FOURTH EDITION, 1175.
ALL JOINTS ARE TO BE SEALED WITH 2 -1/2" "SMAGNA" APPROVED PRESSURE
SENSITIVE ALUMINUM TAPE MEETING AFTS 100 -13 STANDARDS AND THE
REQUIREMENTS OF U.L. 151. APPLICATION SHALL BE IN ACCORDANCE WITH
AFTS 101 -73. (REFER TO MANUFACTURER'S INSTRUCTION SHEET FOR
SPECIFIC DETAILS FOR U.L. 151 REQUIREMENTS.) RECOMMEND FASSON
0505. DO NOT APPLY AT TEMPERATURE BELOW 32 F.
DUCTWORK - EXCEPTIONS
DUCTWORK FOR EXHAUSTING AIR OR OUTSIDE SUPPLY AIR SHALL BE ALL
METAL AND CONSTRUCTED ACCORDING TO RECOMMENDED PRACTICES AS FOUND
IN THE LATEST ISSUE OF ASHRAE.
SUPPORT OF DUCT SYSTEM
DUCTWORK SHALL BE SUPPORTED AT ALL TURNS AND TRANSITIONS AND NOT
MORE THAN 5' O.G. FOR STRAIGHT DUCTS UP TO 35" TO 5C," MAXIMUM
DIMENSION, 6' O.G. AND DUCTS OVER 60: MAXIMUM DIMENSION, 4' O.G.
HANGER DESIGN SHALL BE AS DESCRIBED IN THE LATEST EDITION OF THE
"SMAGNA" MANUAL. REINFORCEMENT MEMBERS MAY BE USED TO SUPPORT THE
DUCT SYSTEM PROVIDED DETAILS OUTLINED IN THE AFOREMENTIONED
DOCUMENTS ARE ADHERED TO.
REINFORCEMENT
ALL DUCTS REQUIRING REINFORCEMENT SHALL BE REINFORCED ACCORDING TO
THE LATEST EDITION OF "SMAGNA" MANUAL.
MATERIALS FOR REINFORCEMENT MEMBERS SHALL BE GALVANIZED STEEL. ALL
SCREWS AND WASHERS SHALL BE PLATED OR GALVANIZED.
ACCESSORY ITEMS
ALL MANUAL DAMPERS, FIRE DAMPERS, TURNING VANES, REGISTER CONNEC-
TIONS, ACCESS DOORS OR OTHER ASSOCIATED ACCESSORIES SHALL BE
INSTALLED ACCORDING TO THE LATEST PUBLICATION OF "SMAGNA" MANUAL.
PIPING
A. PIPING AND FITTINGS SHALL BE OF THE WEIGHTS AND TYPES SHOWN ON
THE DRAWINGS. SIZES SHOWN ON THE DRAWINGS ARE NOMINAL PIPE
SIZES.
B. ALL PIPING SHALL BE INSTALLED PARALLEL TO, OR AT RIGHT ANGLES
WITH THE BUILDING WALLS AND PARTITIONS AND SHALL BE INSTALLED
WITH THE PROPER PITCH.
G. ALL PIPING SHALL BE UPENDED AND POUNDED TO REMOVE ANY FOREIGN
MATTER PRESENT AND SHALL BE SWABBED IF NECESSARY.
PLUMBING
MATERIALS
A. SANITARY SEWER - CAST IRON OR COPPER PIPING MAY BE USED EXCEPT
THAT ALL PIPING BELOW GRADE SHALL BE GAST IRON. VENTS TWO
INCHES (2 ") IN SIZE AND SMALLER MAY BE EITHER SCHEDULED 40
GALVANIZED STEEL OR COPPER PIPING.
B. DOMESTIC HATER AND HOT WATER PIPING SHALL BE COPPER TYPE "L"
INSULATED WITH ARMAFLEX OR EQUIVALENT INSULATING TO A THICK-
NESS OF I ".
G. GAS PIPING SHALL BE BLACK STEEL SCHEDULED 40 WITH SCREWED
FITTINGS.
D. CHILLED WATER SUPPLY AND RETURN PIPING SHALL BE GALVANIZED
STEEL PIPE (STANDARD WALL) OR TYPE "M" HARD COPPER TUBING.
ALL PIPING SHALL BE INSULATED WITH I" THICK OVENS CORNING
FIBERGLASS 25 ASJ /SSL OR EQUAL.
MAKING UP PIPE
A. SCREWED PIPE SHALL BE MADE UP WITH PIPE COMPOUND APPLIED TO
THE MALE THREAD WITH NOT MORE THAN TWO THREADS LEFT EXPOSED.
PIPE SHALL BE REAMED AFTER THREADING.
B. BELOW GRADE SANITARY PIPING SHALL BE CAST IRON PIPE AND SHALL
BE MADE UP WITH ONE THIRD OF THE HUB CAULKED WITH FIRST
QUALITY OAKUM, AND THE REMAINDER FILLED WITH FIRST QUALITY
CAULKING AT ONE POURING AND CAULKED TIGHT. ABOVE GRADE TOG
SHALL HAVE OPTION OF USING PVC AS CODE PERMITS.
G. COPPER JOINTS SHALL BE MADE UP WITH 15 -5 SOLDER.
HANGERS AND SUPPORTS
HORIZONTAL PIPING SHALL BE SUPPORTED AT INTERVALS NOT TO EXCEED
10' -0" WITH SWIVEL SPLIT PIPE HANGERS EQUAL TO CRANE NO. 11IF OR
GRINNELL NO. 104. VERTICAL PIPING SHALL BE SUPPORTED BY MEANS OF
WROUGHT IRON CLAMPS SUSPENDED FROM THE UNDERSIDE OF STRUCTURE WITH
HANGER RODS.
K
(f) CO
+ p N ao
i 1 cOr
H cc
w
7 ~�
1 / n I
� <ZN
w O
O H ,.
W
Z
NZ0
U)N<I
L1
I°
W
W
W
Drawn by:
MWS
Checked By:
RR
LL
0
0
11�
z
T—
O
t9
Drawing Name:
05288. DWG
00
00
00
0D
rt
I
sV
X
�r 8492
\ 1e)
RE ''; ". " R
J \,;CI - JiECT
STATE C_ N::: ;" �a
0
CL
Y-
m
w
F-
Q
()
C3
V")
w
J —I 00
J -I 00
1
2 DO
It
w
LIZ4
0 w
Z U
LI
O 4 °
D J
I-t
0 D
w
Y D C)
0 r
Store No, 5288
Date:
6/7/2007
Date:
DATE CHECKED
CLEANOUTS
GLEANOUTS SHALL BE AS MANUFACTURED BY JOSAM, ZURN MFG. GO. OR EQUAL
AND SHALL BE INSTALLED AT ALL BENDS, ANGLES, AND ENDS OF ALL HASTE
AND SEWER LINES, AS GALLED FOR ON THE DRAWINGS, AND AS REQUIRED BY
LOCAL CODES. ALL CLEANOUTS SHALL BE BROUGHT TO GRADE, AND IN ALL
CASES, SHALL BE PROVIDED WITH SUFFICIENT SPACE FOR RODDING.
FIXTURES
A. WATER CLOSET -EQUAL TO AMERICAN STANDARD 421 Oct .SER WITH CHURCH
SEAT #5330.063 1/2" C.W. SUPPLY AND 4" VENTED WASTE.
B. WATER CLOSET (HANDICAP), WHEN SPECIFIED - EQUAL TO AMERICAN
STANDARD #2105.405 ELONGATED WATER SAVER CADET IS" HIGH WITH
OLSONITE #15 CLOSET SEAT AND 3405.016 SUPPLY PIPE.
C. LAVATORY - EQUAL TO AMERICAN STANDARD #0361.055 WITH
#2235.552 WITH WR15T BLADE HANDLES AND POP -UP DRAIN FAUCET
SET, 1/2" G.W. AND H.W. SUPPLY AND I -1/2" VENTED HASTE.
(WHEN SPECIFIED HANDICAPPED MOUNT BOTTOM OF RIM c4 2c1" A.F.F.)
D. MOP SINK - EQUAL TO "FIAT" PRODUCTS MODEL #MSB -2424 24" x
24" ONE -PIECE MOLDED STONE WITH 3" DRAIN, VINYL BUMPERGUARD
ON 3 SIDES. SERVICE FAUCET #530 -AA; 5" GTR. TO GTR. INLETS
WITH BACK FLOW PREVENTERNAGUUM BREAKER HOSE AND HOSE BRACKET
#532 -AA. PROVIDE 3" VENTED HASTE WITH "P- TRAP "; 1/2" HOT AND
GOLD HATER SERVICE. CAULK WITH A SILICONE SEALANT ALONG
WALLS. MOUNT MOP HANGER AT 4' -0" A.F.F. ALL MATERIALS FUR-
NISHED AND INSTALLED BY OWNER'S CONTRACTOR.
E. FLOOR DRAIN - EQUAL TO JOSAM 3" #303 CAST IRON DRAIN WITH
NICKEL - BRONZE ADJUSTABLE STRAINER; INSIDE CAULK. OUTLET AND
CLAMPING DEVICE WHERE REQUIRED.
F. HATER HEATER - TYPE EQUAL TO RHEEM "POINT OF USE" MODEL. 10
GALLON CAPACITY 1500 WATTS AT 12O/I/60. INSTALL ABOVE TOILET
ROOM WITH TEMPERATURE AND PRESSURE RELIEF VALVE PIPED TO MOP
SINK AS AN INDIRECT WASTE.
G. PAPER TOWEL DISPENSER - DISPENSES 400 C -FOLD OR 525 MULTIFOLD
PAPER TOWELS. CABINET - STAINLESS STEEL (BOBRICK EQUIPMENT
#B -262 OR EQUIVALENT).
H. MIRROR - IS" X 30" WITH ONE PIECE ROLL FORMED FRAME, TYPE
304 STAINLESS STEEL, WITH CONGEALED HANGER (BOBRICK EQUIPMENT
#B -2q0 OR EQUIVALENT).
I. SURFACE MOUNTED SOAP DISPENSER - PUSH -UP DISPENSER WITH
VISIBLE CONTAINER AND CHROME PLATED MOUNTING BRACKET (BOBRIGK
EQUIPMENT #BI55 OR EQUIVALENT).
J. SURFACE MOUNTED TISSUE DISPENSER - HEAVY DUTY ALUMINUM
CASTING; MOLDED HIGH IMPACT PLASTIC SPINDLES; HOLD 2000
SHEET ROLLS (BOBRICK EQUIPMENT #B -273O W/O CONTROLLED DELIVERY
OR EQUIVALENT).
K. GRAB BARS FOR THE PHYSICALLY HANDICAPPED, AS REQUIRED: IS
GAUGE, TYPE 304 STAINLESS STEEL WITH NON -SLIP GRIPPING SUR-
FACE; EXPOSED MOUNTING PLATES - LENGTHS AS REQUIRED BY STATE
AND LOCAL GODES (BOBRIGK EQUIPMENT #B-6I06 SERIES OR
EQUIVALENT).
L. WASTE RECEPTACLE - METAL FREE STANDING WASTE WITH OPEN TOP.
M. OWNER'S CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER
INSTALLATION OF ALL TOILET ACCESSORIES INCLUDING PROPER
BLOCKING IN WALL.
N. DRINKING FOUNTAIN - TYPE EQUAL TO ELKAY #EBFSA -S BARRIER FREE WALL
MOUNTED WATER COOLER. 5 GPH CAPACITY, 4.5 FLA, 410 WATTS, I/5 H.P.
0. SINK PUMP SYSTEM - MYERS MODEL #ED -25 ABOVE GROUND
WASTE WATER PUMPING SYSTEM. THE PLUMBING CONTRACTOR
SHALL INSTALL THE SYSTEM ACCORDING TO ALL RECOMMENDATIONS
OF THE MANUFACTURER. A CHECK VALVE SHALL BE INSTALLED
ON THE DISCHARGE AS PER MANUFACTURER. 5A/120V/I PHASE.
VALVES
ALL VALVES SHALL BE BRASS AND MANUFACTURED BY CRANE, NIBGO,
STOCKHAM, LUNKENHEIMER, NORDSTROM, GRINNELL OR EQUAL.
SPRINKLER SYSTEM
A. SHOP DRAWINGS - THE SPRINKLER CONTRACTOR SHALL SUBMIT SHOP
DRAWINGS TO THE TENANT'S LANDLORD AND TO THE APPROPRIATE
RATING BUREAU FOR THEIR APPROVAL. A COPY OF THE APPROVAL
LETTER FROM THE RATING BUREAU SHALL BE FORWARDED TO THE
TENANT'S LANDLORD AND TO:
MIKE GORMAN
GENERAL NUTRITION CORPORATION
300 SIXTH AVENUE
PITTSBURGH, PA 15222
13. SPRINKLER HEADS - SHOW WINDOWS - HIGH TEMPERATURE. CHROME
PLATED, COMPLETELY RECESSED TYPE. SALES AND OFFICE AREA -
CHROME PLATED, SEMI - RECESSED TYPE. STORAGE, TOILET AND WORK
AREA WITH CEILINGS - BRASS, PENDANT TYPE. STORAGE AND WORK
AREA WITHOUT CEILINGS - BRASS UPRIGHT TYPE.
ROUGH -INS
FOR SECOND LEVEL STORES, THE TENANT'S GENERAL CONTRACTOR SHALL RUN
ALL LINES REQUIRED FOR PLUMBING ROUGH -INS TIGHT AGAINST THE UNDER-
SIDE OF THE SECOND FLOOR LEVEL. THE SECOND FLOOR STRUCTURAL SLAB
SHALL BE CORED AS REQUIRED TO INSTALL THESE ITEMS AT THE LOCATIONS
SHOWN ON THE PLANS.
TESTING AND ADJUSTING
CONTRACTOR WILL DEMONSTRATE OPERATION OF SYSTEM TO FULL SATIS-
FACTION OF TENANT, WILL BALANCE AIR FLOW IN ACCORDANCE WITH AIR
QUANTITIES ON DRAWINGS AND WILL RECORD VOLUME READINGS IN ACCOR-
DANCE WITH ASHAE AND PROVIDE SAME TO TENANT. GAS PIPING SHALL
WITHSTAND AIR PRESSURE TESTING PER UNIFORM PLUMBING CODE.
GUARANTEE
ALL MATERIALS, EQUIPMENT, AND WORKMANSHIP SHALL BE GUARANTEED FOR
A PERIOD OF ONE (I) YEAR AFTER DATE OF ACCEPTANCE. THE COMPLETED
SYSTEM SHALL BE FULLY OPERATIVE AND ACCEPTANCE BY TENANT SHALL BE
A CONDITION OF THIS CONTRACT. ALL WORK FOUND TO BE DEFECTIVE SHALL
BE REPAIRED OR REPLACED BY THIS SUBCONTRACTOR WITHOUT ADDITIONAL
CHARGE TO THE TENANT.
MECHANI CAL
TEMPORARY SERVICES
CONTRACTOR THE G CTOR SHALL PROVIDE THE FOLLOWING SPECIFIC ITEMS OF
TEMPORARY SERVICES:
A. TELEPHONE - THE TENANT'S GENERAL CONTRACTOR SHALL INSTALL A
JOB SITE TELEPHONE AND NOTIFY TENANT AS LISTED ON SHEET A -I
OF THE TELEPHONE NUMBER AND THE NAME OF THE SUPERINTENDENT.
B. TEMPORARY WATER - WATER REQUIRED IN THE PERFORMANCE OF THE
CONTRACT SHALL BE PROVIDED AND PAID FOR BY THE CONTRACTOR.
WATER USER FOR HUMAN CONSUMPTION SHALL CONFORM TO REQUIRE-
MENTS OF STATE AND LOCAL AUTHORITIES FOR POTABLE WATER.
G. TEMPORARY ELECTRICITY - TEMPORARY ELECTRIC SERVICE REQUIRED
IN THE PERFORMANCE OF THE CONTRACT SHALL BE FURNISHED AND
PAID FOR BY THE CONTRACTOR WHO SHALL FURNISH, INSTALL, AND
MAINTAIN ALL TEMPORARY OVERHEAD CONSTRUCTION, METERS, DROPS,
AND OTHER WIRING AND FITTINGS FOR BOTH LIGHT AND POWER AT
LOCATIONS REQUIRED IN THE WORK AND SHALL BEAR THE COST OF
MAKING THE SERVICE CONNECTIONS. BEFORE FINAL ACCEPTANCE,
TEMPORARY ELECTRICAL SERVICE FACILITIES INSTALLED BY THE
CONTRACTOR SHALL BE REMOVED AND THE SERVICE CONNECTIONS
SEVERED IN ACCEPTABLE MANNER.
^ttti wl .
D. TEMPORARY HEAT - WHEN REQUIRED FOR PROPER INSTALLATION OR
PROTECTION OF ANY PORTION OF THE WORK, THE CONTRACTOR SHALL
FURNISH AND INSTALL TEMPORARY HEATING UNITS AS APPROVED BY
THE LANDLORD OR LOCAL AUTHORITY.
E. COST OF LANDLORD PROVIDED UTILITY SERVICES - IF THE LANDLORD
ELECTS TO PROVIDE TEMPORARY UTILITY SERVICES, THE CONTRACTOR
WILL BE SO INFORMED BY THE TENANT. THE CONTRACTOR SHALL MAKE
PROVISIONS OR COORDINATE WITH LANDLORD'S GENERAL CONSTRUCTOR
TO PAY THE COST OF SAID TEMPORARY CONSTRUCTION AND UTILITY
SERVICES.
NOTE FOR TENANT GENERAL CONTRACTOR
IT IS THE RESPONSIBILITY OF THE TENANT'S GENERAL CONTRACTOR TO
MAKE USE OF APPLICABLE NOTES AND SPECIFICATIONS LISTED ON THIS
SHEET AS THEY MAY PERTAIN TO THE SPECIFIC JOB.
HANDICAP SPECIFICATION: ARCHITECTURAL BARRIERS ACT, 42 USG. 4151 -415
GENERAL
THE WORK COVERED BY THESE SPECIFICATIONS INCLUDES BUT IS NOT
LIMITED TO PROVIDING ALL LABOR, MATERIAL, AND EQUIPMENT NECESSARY
TO COMPLY WITH HANDICAP REQUIREMENTS IN THIS ESTABLISHMENT.
TOILET ROOM ACCESSORIES
A. MIRROR BOTTOM EDGE SHALL BE LOCATED 40" MAXIMUM ABOVE FLOOR.
(4.11.6)
B. TOILET TISSUE DISPENSER SHALL BE MOUNTED WITHIN 12" FROM THE
FRONT EDGE OF TOILET SEAT. 11" MIN. A.F.F. (4.16.6)
G. OPERATING PARTS OF DISPENSER AND DISPOSAL FIXTURES SHALL BE
WITHIN 40" OF FLOOR. (4.23.1)
WATER CLOSET GRAD BARS
A. ONE AT SIDE 42" LONG EXTENDING IN FRONT OF WATER CLOSET; ONE
AT REAR 36" LONG CENTERED ON WATER CLOSET; BOTH MOUNTED 36"
ABOVE FLOOR. (4.26)
B. BARS SHALL BE I -1/4" - I -1/2" IN DIAMETER WITH I -1/2" CLEAR-
ANCE TO WALL. (4.26)
G. BAR FASTENERS AND MOUNTING SUPPORT SHALL WITHSTAND 250 LBS./
FT. BENDING, SHEAR, AND TENSION. (4.26)
WATER CLOSET
A. HEIGHT OF HATER CLOSET SEAT SHALL BE IS" A.F.F.; AMERICAN -
STANDARD MODEL 21005.416. (4.16)
B. FORGE REQUIRED TO ACTIVATE FLUSH VALVE SHALL BE 5 LBS.
MAXIMUM (4.16.5)
LAVATORY
A. PROVIDE 30" x 45" CLEAR FLOOR SPACE FOR FORWARD APPROACH,
INCLUDING KNEE AND TOE SPACE. (4.Iq.3)
B. PROVIDE CLEAR SPACE BENEATH LAVATORY 2C," HIGH x 30" WIDE x
5" DEEP (KNEE SPACE) AND 1" HIGH FROM THE FLOOR x 30" HIDE x
I7" DEEP FROM FRONT OF LAVATORY (TOE SPACE). (4.Iq.2)
G_ . HOT HATER AND DRAIN PIPE UNDER LAVATORY SHALL BE INSULATED
WITH ARMSTRONG ARMFLEX PIPE INSULATION. MITER GUT PIECES
JOINTED TOGETHER WITH ARMSTRONG 520 ADHESIVE. (4.11.4)
D. FAUCET CONTROLS AMERICAN STANDARD ( OR EQUAL) SHALL
BE OF THE TYPE NOT REQUIRING TIGHT GRASPING, PINCHING, OR
TWISTING OF WRIST AND AN OPERATING FORCE NOT EXCEEDING 5
LBS. (4.11.5)
SELF - CLOSING VALVES SHALL BE OF THE TYPE REMAINING OPEN FOR AT
LEAST 10 SECONDS. (4.11.5)
tdd 4 Brmiaffis+
FOR
CODE COMPLIANCE
APPROVED
t p ° 1 200E
O Tukwila
RECEIVED
APR 2 2 1000
PERMIT CENTS I
Drawing No.
7