Loading...
HomeMy WebLinkAboutPermit M08-114 - WESTFIELD SOUTHCENTER MALL - SEATTLE TEAM SHOP KIDSSEATTLE TEAM SHOP KIDS 1057 SOUTHCENTER MALL M08 -114 Parcel No.: 6364200010 Address: Suite No: Tenant: Name: Address: DESCRIPTION OF WORK: NEW VAV, CONTROLS, AND DUCT DISTRIBUTION Value of Mechanical: $35,000.00 Type of Fire Protection: SPRINKLERS /AFA Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC-10/06 CitAf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 1057 SOUTHCENTER MALL TUKW SEATTLE TEAM SHOP KIDS 1057 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: KEITH SMITH Address: 1725 WESTLAKE AV N, STE 210 , SEATTLE WA Contractor: Name: OKITSU CONSTRUCTION INC. Address: 1428 WHI TWORTH AV S , RENTON WA Contractor License No: OKITSCI959L8 MECHANICAL PERMIT EQUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 0 0 0 1 0 0 0 0 * *continued on next page ** M08 -114 • Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 713 -4076 Phone: 206 714 -9969 Expiration Date: 06/28/2009 M08 -114 06/11/2008 01/06/2009 Fees Collected: $683.75 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 07 -21 -2008 Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied Signature: Print Name: doc: I MC -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us t h, The granting of this p: t • oes not presume to give auth construction or the p rfo ce of work. I am 47thorized'" and obtain this mechanical permit. • Permit Number: MO8 -114 Issue Date: 06/11/2008 Permit Expires On: 01/06/2009 Date: 1,tifb ed this permit and know the same to be true and correct. All provisions of law and ordinances hether specified herein or not. o violate or cancel the provisions of any other state or local laws' regulating Date: 7-- 2 /---0R This permit shall become null and void if the work is not cpmmenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M08 -114 Printed: 07 -21 -2008 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: doc: I MC -10/06 City I tf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 6364200010 1057 SOUTHCENTER MALL TUKW WESTFIELD VANILLA BOX 1057 SOUTHCENTER MALL , TUKWILA WA WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD CA Contact Person: Name: KEITH SMITH Address: 1725 WESTLAKE AV N, STE 210 , SEATTLE WA Contractor: Name: OKITSU CONSTRUCTION INC. Address: 1428 WHITWORTH AV S , RENTON WA Contractor License No: OKTTSCI959L8 DESCRIPTION OF WORK: NEW VAV, CONTROLS, AND DUCT DISTRIBUTION Value of Mechanical: $35,000.00 Type of Fire Protection: SPRINKLERS /AFA Furnace: <100K BTU 0 >100K BTU 0 Floor Furnace 0 Suspended/Wall/Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System.... 0 Air Handling Unit <10,000 CFM 0 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 1 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial/Industrial 0 MECHANICAL PERMIT Fees Collected: $563.75 International Mechanical Code Edition: 2006 EQUIPMENT TYPE AND OUANTITY * * continued on next page ** • Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 713 -4076 Phone: 206 714 -9969 Expiration Date: 06/28/2009 M08 -114 06/11/2008 12/08/2008 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment M08 -114 Printed: 06 -11 -2008 Permit Center Authorized Signature: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read and x. ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied , whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or th erformance of work. f authorized to sign and obtain this mechanical permit. Signature: Print Name: doc: I MC -10/06 • Permit Number: M08 -114 Issue Date: 06/11/2008 Permit Expires On: 12/08/2008 Date: NI tti Date: (/// This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M08 -114 Printed: 06-11 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 1057 SOUTHCENTER MALL TUKW SEATTLE TEAM SHOP KIDS 1: ** *BUILDING DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS • Permit Number: Status: Applied Date: Issue Date: M08 -114 ISSUED 04/24/2008 06/11/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 7: ** *FIRE DEPARTMENT CONDITIONS * ** 8: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 9: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 10: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 11: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 12: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 13: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 14: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 15: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this doc: Cond -10/06 M08 -114 Printed: 07 -21 -2008 project. • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 17: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 18: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** M08 -114 Printed: 07 -21 -2008 doc: Cond -10/06 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: '7 Date: Print Name: ) fi �, b -1) M08 -114 Printed: 07 -21 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: 1057 SOUTHCENTER MALL TUKW WESTFIELD VANILLA BOX 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS • Permit Number: Status: Applied Date: Issue Date: M08 -114 ISSUED 04/24/2008 06/11/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 7: ** *FIRE DEPARTMENT CONDITIONS * ** 8: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 9: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 10: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 11: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 12: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 13: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 14: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 15: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this doc: Cond -10/06 M08 -114 Printed: 06-11 -2008 project. • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • 16: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 17: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 18: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** M08 -114 Printed: 06-11 -2008 Signature: /-"" d doc: Cond -10/06 City of Tukwila Print Name: C. 4 4` Y'r' Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us S I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing• this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Date: 00 M08 -114 Printed: 06-11 -2008 / McHTINIMENNIIM TFPERS Day Telephone: - W Site Address: Tenant Name: Property Owners Name: Mailing Address: Name: , /I / 1. MEW, . E -Mail Address: KS,v G 1 Sfl meth h a d,: Mailing Address: GENE L' CONTRAC1PR OW.P . - 1 a; ;P �i(Contraetor'Inforniabon fogMechaoica�;(pg 4),f_or,Plumbing`+ Gas�P�pmg:(pg +5)) �,, Company Name: ? • Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: • Contractor Registration Number: Expiration Date: Company Name: �✓/ � D7 /'t L �'f L "C/ Mailing Address: Contact Person: E -Mail Address: Y.ENGIl E ER i ti REC . 1 - L,:�e 9.t s�?r'»»x:.,F /t.:ea.va...�.,, - ... .t.. z•. r. ?� �d!.9.s Company Name: Mailing Address: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: //www. ci. tukwila. wa. us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** COP ` lansmustr be ' ,wet � stampe d Contact Person: E -Mail Address: QMppliestions\Fmen- Applicarions On Line V-2006 Permit Applicariondoe Revised 9 -2006 bh King Co ssessor's Tax No.: 63(4,1 � Suite Number: Floor: v Y • New Tenant: )4 Yes El ..No City Fax Number: City Day Telephone: Fax Number: Engineer oft,Record I State d9 4.4‘k lee State State Zip City Day Telephone: Fax Number: Zip Page 1 of 6 r d ` �ri •, At 4 -'��' { i �!:`�'tt { j 4 � f f .:E,gstirig �. r .,. � , � Y _Interion emodel :. t ='''"Additionito a . f s x ,. � , ' .J Exi tmg r ' ', Structure .;, - 4 ' 1 f "Y r.` < . New. , .: r , YPe� of ° Co r nstructs • , p er l I s U <'Trnctiof Occu cy er � P r ... WI13C;., 1 ,1 Floor. r .. ''2°d Floor �� y t. . t. -. �. .} i `3 %Floor' , ,, ,f'a fl diii r �* thrll;�') t ,.., t� M S . , 1: e i y Weeigsory'Stiiit � : '. ;;, 7; 5• .i ''i C. .., :;, .sit:! ^':8T• r j� • Aii :i) 4cligd G a r a g e =s. >.' ::,, a, +�,:,.;, `:.Fft'1 111 ` Gara�ge" r ,...i.y': y.',:s•-..„,..:- ,rvf l7 ,.� �•,J ;. Py {��� .. €fAtfached Carport <,` ' ti ,,:1,06.„-,$...-i $ t., } <r I.,' r +rD "e "taelied CarPoit i <`: - ° %':. ; ?; i ., : �44:, � k" . Lii � f^, ,, t'CoveredDec f t ,',.',';•4 5 Fes•. '.(�` }'- { � ' i Uncover d Deck , r r f l y I UILDINGTERM T INFORMATION- 2206 31 Valuation of Project (contractor's bid price): $ //5" 5" Scope of Wo k (ple e prov ' e detailed i formation): f / ,4:i /i t zk' plvmbih Will there be new rack storage? ❑ Yes FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers [t�.......Automatic Fire Alarm Q: Applicatitms\Pomn- Applications On rane\3•2006 - Pamir Applcation.doe Revised' 9-2006 bh • Existing Building Valu. ion: $ v i d M1.- a MA 1' [ No If yes, a separate permit and plan submittal will be required. PLANNING DIVISION: Single family building footprint (area . , e foundation of all structures, plus any decks over 18 es and overhangs greater than 18 inches) For an Accessory dwellin: ., • ' ' the following: Lot Area (sq ft): • Floor area of principal dwelling: oor area of accessory dwelling: *Provide documenta that shows that the principal owner lives in one of the dwellings as his o er primary residence. Number of Parting Stalls • vided: Standard: Compact: Handicap: Will there be a chang- . use? ❑ Yes s i r No If `yes ", explain: N one ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous mate in the building? ❑ Yes V No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department_ Page 2 of 6 Unit Type:' , ... - Qty Unit Type::' _ Qty Unit Type: Qty Boiler /Compressor: s' - . Qty Fumace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Fumace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct ( Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Hy at/Refrig/Cooling System Incinerator - Domestic Other Mechanical 41:i ay _ ,/ _ £x(/� Air Handling Unit <10,000 CFM Incinerator — Comm/Ind . `I IECIAANICAL PERMITINFORMATION =-204-431;3610 MECHANICAL CONTRA TOR INFORMATION Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $ _ 0 Scope of Work ()lease kai'Ipd information): Cc Ai Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New ...., Replacement .... ❑ Fuel Type: Electric 12, , Q: WppGeetions\Fmen- Applications On Line\3 -2006 - Permit Applieation.doc Revised: 9.2006 bh State Zip 04/ ea-nh;e4 cket Gas .... ❑ Other: Indicate type of mechanical work being installed and the quantity below: Page 4 of 6 1 I 'PUB LIC WORKS'PEI2IVII y URIVIATI�O1V� t 244643'34 1 79 Scope of Work (please provide d ile�i information): � Water District Tukwila ...Water Availability Provided S e er District ...Tukwila ❑ ...Sewer Use Certificate Septic System: ❑ On -site Septic System — For on -site septic sy Submi ed with A • • lication ma k boxes which a ❑ ...Civil Plans (Maximum Paper Size — 22" x 34 ") ❑ ...Technical Infomnation Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easem Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ ... Construction /Excavation/Fill - Right -of -way Non Right-of-way ❑ ...Total Cut ❑ ...Total Fill ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic ❑ ...Permanent Water Meter Size. ❑ ...Temporary Water Meter S' ❑ ...Water Only Meter Size.. ❑ ..Sewer Main Extension ❑ ...Water Main Extensi Fire Line Size at ❑ ...Water 0 Monthly Service Billing to: Name: Mailing Address Water Meter Refund/Billina: Name: Mailing Address ❑ ...Sewer cubic yards cubic yards .Water District #125 ❑..Val ❑ ... Sewe : vailability Provided ❑.. QAApplicationsWorms- Applicatimn On L ne13 -2009- Permit Applicetion.doe Revised 9 -2006 bh Call before you Dig: 1- 800 -424 -5555 Please `ref�r.;to;Riblic,Wocks:BgDetin #1.0 fees and e§timatetsheet:, perry Line Number of Public Fire Hydrant(s) ❑ ...Sewage Treatment (s) t� 1 ;!L _4.11 • ter Public Private Public Private don Septic Tank b Cut avement Cut .. Looped Fire Line tl WO # WO # WO # ❑ .. ❑..Sto ❑...Deduct Water Me • ❑ .. Highline ❑ .. Renton ❑ .. Renton ❑ .. Seattle m, provide 2 copies of a current septic design ved by King County Health Department. ❑ .. Geotechnical ❑ .. Maintenan ='• ort ❑ ...Traffic Impact Analysis greement(s) ❑...Hold Harmless — (SAO) ❑...Hold Harmless — (ROW) si t-of -way Use - Profit for less than 72 hours ght-of -way Use — Potential Disturbance in Flood Zone nage City ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding Size Day Telephone: State Zip Day Telephone: City State Zip Page 3 of 6 1 :PERMITt .._ ,;e r APPIJICATION NOTES`.— p Appl�cable to al! permits idthts,applicahon :S F�' a '�..4i%?. .�; \ Pi k; i�:: t'.: k�i ' "?t. , .;Z` "r.Y . s ' 1 q".,�.,"'r� {s � w:af..t;'r+.larii�r'6, t ad�^�+a�jl!? 1 Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the dale of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE • S J . 0 RIZED AGENT: Signature: Print Name: Mailing Address: Date Application Accepted: (Mv-I I in Q: ApplicationsWotn s- Applications On Line \3-2006 - Permit Application.doe Revised 9-2006 bh Day Telephone: ( tt It Date: 4(4-(e State Date Application Expires: 017-L4 1, Staff Initials: Page 6 of 6 Fixture;Type . ui ;.city: �F iature°Type. i, ; ., a 3 o _ E 'ii .�` ixt:ure� ea:' -Q{Y • _., :%I'° ' �.Eiztti'r`e:�Type , u ,�, cQ Bathtub or combination bath/shower Drinking fountain or wa cooler(per head) Wash fountain Gas piping outlets Bidet Food -waste grinder commercial R. -ptor, indirect was Clothes washer, domestic Floor drain ( Sinks ' .. Dental unit, cuspidor Shower, sin head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Clo < - / Building sewer or trailer park sewer Rain a t e r system — per :'. (inside building) Water heater an; ... r vent ( Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors • air or alteration of water • iping and/or water treating equipment Repair or alteration of drainage or vent piping / Medical gas piping system serving one to five inlets/outlets for specific gas " ia∎ al.K GAS PIPINGiP-E¢ i,�g,,�� Ialk•N 4 166 431 3 70 _ , = "4,�.� g�..�x n t b ka FIIA•Cr.Y..-°UM— 1. "t PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Th Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Plumbing w• (contractor's bid price): $ 2 00 0 Valuation of Gas Piping wor .ntractor's bid price): $ Scope of Work (please provide iled information): i €4 /e Building Use (per Int'1 Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Indicate type of plumbing fixtures and/or gas piping outlets Q :lApplicationsWottwApplications On Line\3- 2006 - Permit Application.doe Revised 9 -2006 bh Sewer: g installed and the quantity below: Page 5 of 6 n .. Dtf CV re nc RECEIPT NO: R08 -02677 Initials: JEM User ID: 1165 Payee: DAVID R. WORLEY SET TRANSACTIONS: Set Member Amount ACCOUNT ITEM LIST: Description City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http.• //www. ci. tukwila. wa. us D08 -143 71.88 D08 -168 618.36 D08 -169 60.00 D08 -218 71.88 D08 -219 60.00 D08 -221 60.33 D08 -225 60.33 D08 -240 71.88 M08 -081 60.00 M08 -082 60.00 M08 -083 60.00 M08 -095 71.25 M08 -112 120.00 M08 -113 60.00 M8?EENI 60.00 M08 -115 60.00 M08 -116 60.00 M08 -124 60.00 TOTAL: 1,745.91 SET RECEIPT TRANSACTION LIST: Type Method Description Amount Payment Check 1115 1,745.91 TOTAL: 1,745.91 Account Code Current Pmts Payment Date: 07/21/2008 Total Payment: 1,745.91 SET ID: 0717 SET NAME: WESTFIELD REVISIONS 109 07/21 9710 TOTAL 1745.91 e r BUILDING - NONRES MECHANICAL - NONRES PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us 000/322.100 360.40 000.322.102.00.0 669.00 000/345.830 716.51 TOTAL: 1,745.91 Parcel No.: 6364200010 Address: Suite No: Applicant: WESTFIELD VANILLA BOX Receipt No.: R08 -02228 Initials: WER User ID: 1655 Payee: TRANSACTION LIST: Type Method rinr. Raeaint -06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 1057 SOUTHCENTER MALL TUKW OKITSU CONSTRUCTION Payment Check Descriptio 1669 ACCOUNT ITEM LIST: Description Account Code RECEIPT Amount 60.00 MECHANICAL - NONRES 000.322.102.00.0 Current Pmts 60.00 Total: $60.00 Permit Number: Status: Applied Date: Issue Date: M08 -114 ISSUED 04/24/2008 06/11/2008 Payment Amount: $60.00 Payment Date: 06/23/2008 02:06 PM Balance: $0.00 Printpri: ns- 73 -9nnR RECEIPT NO: R08 -02074 Initials: WER User ID: 1655 Payee: OKITSU CONSTRUCTION, INC. SET ID: 0611 SET NAME: WESTFIELD MECHANICAL SET TRANSACTIONS: Set Member ' Amount M08 -081 406.00 M08 -082 406.00 M08 -083 406.00 M08 -095 406.00 M08 -096 406.00 M08 -112 811.00 M08 -113 811.00 Maip 811.00 M08- 11''5 811.00 M08 -116 811.00 M08 -152 244.00 TOTAL: 6,329.00 TRANSACTION LIST: Type Method Description Payment Check 1664 6,329.00 TOTAL: 6,329.00 ACCOUNT ITEM LIST: Description Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www. ci. tukwila. wa. us MECHANICAL - NONRES PLAN CHECK - NONRES City of Tukwila SET RECEIPT Payment Date: 06/11/2008 Total Payment: 6,329.00 Amount Account Code Current Pmts 000.322.102.00.0 4,529.00 000/345.830 1,800.00 TOTAL: 6,329.00 3540 06/11 9711 TOTAL 6329 =00 RECEIPT NO: R08 -01309 Initials: JEM Payment Date: 04/24/2008 User ID: 1165 Payee: WESTFIELD SET ID: S000001009 SET NAME: Tmp set /Initialized Activities SET TRANSACTIONS: Set Member Amount City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http:/lwww.ci.tukwila.wa.us D08 -220 895.70 EL08 -462 123.00 MO 11?4, 112 .75 PG08- 1130 29.00 TOTAL: 1,160.45 TRANSACTION LIST: Type Method Description Amount Payment Check 06012500 1,160.45 TOTAL: 1,160.45 ACCOUNT ITEM LIST: Description ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES SET RECEIPT Total Payment: 1,160.45 Account Code Current Pmts 000.345.832.00.0 123.00 000/345.830 1,037.45 TOTAL: 1,160.45 1595 04/24 9711 TOTAL 1160.45 Project: \/..)F Si ck£4 Got- Type of Inspection: 4L Address: Date Called: • Special Instructions: Date - -7— z 3 r o 8 a.m. Requester: Phone No: CITY OF TUKWILA BUILDING DIVISIO N 6300 Southcenter Blvd., #100, Tukwila, WA 98188 IS Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Y a..-1 C .ewN P /,_ 1 b' lA.►'e f e Po r4 • Date: - 7- Z 3-- c' INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT N . I� (206)431 -316 0 I REINSPECTION FEE f SQUIRED. Prior to inspection, fee must be t 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: Project: ., , -^j° Da attri t ! . 52, o p Type of Inspectio , cti< - L ✓''s+'t .trot s w Y■ . Address: 5 '1 riA L Date Called: Special Instructions: Date Wanted: 112Q�a a.m. P.m. Requester: Phone No: INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Mac 1 1 ' 4 PERMIT NO. (206)431 -3670 .Approved per applicable codes. El Corrections required prior to approval. COMMENTS: \)&' -1 1 2 ? 4-uv y' y 4 d J i a„ ) 1 o . / ° pces evi)e5 ulIir Clic Inspecto Date: 7/2 © /o 7 $58.00 REINSPECTION FE REQUIRED. Prior to inspection, fee must be paid at 6300Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: Pr sec : Type of section: Address: i 0 7 rn41l Date Called: Special Instructions: Date tante d:' a.rr�.. Requester: Phone No 0—C) 0 -3 70 — 12 -- INSPECTION RECORD, Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 M Approved per applicable codes. Corrections required prior to approval. COMMENTS: o K 4Osr' Let 1 t LJ $60.00 R O1SPECTION FEE REQUIRED. Prior to inspection, fee must be - • paid at 6 0 Southcenter Blvd., Suite 100. Call to schedule reinspectiort. Receipt No.: 'Date: 1 Proje t: r � // O TYPwf I spect4on! i l rg_ss ?, , �// Date Called: S ec Date anted: !! a.m. Requester: Phon ` ),Njo /o ,erg -pry INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: /� vv 1 VF- � Ifll5t.,te P (‹over Date ,/ q/ Dr J $60,0 f( EINSPECTION FEE REQUIRED. Prior p3 inspection, fee must be paidft 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project: Se 4116* - + - e"-- - 51, v e Type of Inspection:, Address: Suite #: /($ 7 3 . ( . Contact Peron: Special Instructions: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre-Fire: Permits: Occupancy Type: ME- 1H INSPECTION NUMBER CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit Word/Inspection Record Form.Doc 1/13/06 the City of Tukwila Finance Department. Call to schedule a reinspection. PERMIT NUMBERS Corrections required prior to approval. COMMENTS: t oe e j / 4-3 tiJL re_ lvteek OK, Inspector: Date: Hrs.: 0 $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from T.F.D. Form F.P. 113 Project: Se 1G - + - c^ , --- - 5L, t p Typpe Inspection:, Address: Suite #: /t1). 7 S. C . / L. Contact Pe on: Special Instructions: Occupancy Type: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER n Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT Word /Inspection Record Form.Doc 1/13/06 PERMIT NUMBERS 444 Andover Park East, Tukwila, t r Wa. 98188 206 -575- n Corrections required prior to approval. COMMENTS: be4 / 4-3 - ham„, k -1-7) -Ft re- Ito cz L\ - D K. Inspector: I Date: 7 1,56/08 rs.. $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 Project Info Project Address 1057 Southeenter Mall Date 4/7/2008 Tukwila, WA 98188 For Building Department Use Applicant Name: Keith L. Smith Applicant Address: 1725 WeatlakeAve. N., Suite 210 Applicant Phone: Seattle, vim. 98109 2006 Washington State Nonresidential Energy Code Compliance Forms 2006 Washington State Nonresidential Energy Code Compliance Form hi Project Summary PRJ -SUM F LE COPY CODE COMPLIANC PP 5WVED tEIM ' 5 2408 Revised July 2007 RECEIVED CITY OF TUKWILA APR 2 4 2008 PERMIT CENTER Cooling Equipment Schedule Equip. ID Brand Name' Model No.' Capacity Btu /h Total CFM OSA CFM or Econo? SEER or EER IPLV Location FMB -1 TITUS DTFS SIZE 1) 80 500 Econo M -i M -1 1725 WestlakeAve. N., Suite 210 Applicant Phone: Seattle, WA 98109 Fan Equipment Schedule Equip. ID Brand Name' Model No.' CFM SP' HP /BHP Flow Control Location of Service EF -1 GRZE CK SP -B110 100 3 80 W Cv M -i Applicant Address: 1725 WestlakeAve. N., Suite 210 Applicant Phone: Seattle, WA 98109 Heating Equipment Schedule Equip. ID Brand Name' Model No.' Capacity Btu /h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency FMB -1 TITUS 3 Applicant Name: Keith L. smith Applicant Address: 1725 WestlakeAve. N., Suite 210 Applicant Phone: Seattle, WA 98109 Project Info Project Address 1.057 Southcenter Mall Date 4/7/2008 Tukwila, WA 98188 For Building Dept. Use Applicant Name: Keith L. smith Applicant Address: 1725 WestlakeAve. N., Suite 210 Applicant Phone: Seattle, WA 98109 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Summary MECH -S 2006 Washington State Nonresidential Energy Code Compliance Forms Project Description Briefly describe mechanical system type and features. Includes Plans Drawings must contain notes requireing compliance with commissioning requirements - Section 1416 'If available. 2 As tested accord ng to Table 14 -1A through 14 -1G. 3 If required. • COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). Revised July 2007 Compliance Option 0 Simple System 0 Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling or Cooling Only: ❑ Constant vol? ❑ Split system? ❑ Air cooled? ❑ Packaged sys? ❑ <20,000 Btuh? ❑ Economizer included? If Heating Only: < ❑ 5000 cfm? o ❑ <70% outside air? Mechanical Summary (back) MECH -SUM Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. Heating Only No 2006 Washington State Nonresidential Energy Code Compliance Form Reference Section 1421 Yes — Simple System Allowed (section 1420) otal Ca . wo economize <240,000 Btuh or 10 %? Heating /Cooling or Cooling Only Yes ( Reference Section 1423 Use Complex Systems (section 1430) Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. Mechanical Permit Plans Checklist 2006 Washington State Nonresidential Energy Code Compliance Forms MECH -C,HK Revised July 2007 Project Address 1057 southcenter Mall Date 4/7/2 008 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule yes 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency M -2 1411.1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket loss 1412 HVAC controls yes 1412.1 Temperature zones Indicate locations on plans M - 1 1412.2 Deadband control Indicate 5 degree deadband minimum 1412.3 Humidity control Indicate humidistat 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage 1412.4.2 Optimum Start Indicate optimum start controls 1412.5 Heat pump control Indicate microprocessor on thermostat schedule 1412.6 Combustion htg. Indicate modulating or staged control 1412.7 Balancing Indicate balancing features on plans 1412.8 Ventilation Control Indicate demand control ventilation for high - occupancy areas 1422 Thermostat interlock Indicate thermostat interlock on plans 1423 Economizers Equipment schedule 1413 Air economizers 1413.1 Air Econo Operation Indicate 100% capability on schedule 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb 1413.2 Water Econo Doc Indicate clg load & water econoe & clg tower performance 1413.3 Integrated operation Indicate capability for partial cooling 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems 1414.1 Duct sealing Indicate sealing necessary 1414.2 Duct insulation Indicate R -value of insulation on duct 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Completion Requirements 1416.2.1 Commissioning Provide commissioning plan 1416.2.2 -3 Sys.Bal & Func.Test Indicate air and water system balancing & functional testing 1416.2.4 Commissioning Indicate O &M manuals, record drawings, staff training 1416.2.5 Comm. Report Indicate requirements for prelim. & final commissioning report 1434 Separate air sys. Indicate separate systems on plans yes Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. 1441 Elec. water heater Indicate R -10 insulation under tank 1442 Shut -off controls Indicate automatic shut -off 1443 Pipe Insulation Indicate R -value of insulation on piping 1452 Heat Pump COP Indicate minimum COP of 4.0 1452 Heater Efficiency Indicate pool heater efficiency 1453 Pool heater controls Indicate switch and 65 degree control 1454 Pool covers Indicate vapor retardant cover 1454 Pools 90+ degrees Indicate R -12 pool cover 2006 Washington State Nonresidential Energy Code Compliance Form no is circles Tor any question, proviae explanation: ACTIVITY NUMBER: M08 -114 DATE. 07 -11 -08 PROJECT NAME: SEATTLE TEAM SHOP KIDS SITE ADDRESS: 1057 SOUTHCENTER MALL Original Plan Submittal. Response to Incomplete Letter Response to Correction Letter # X Revision # 2 After Permit Issued DEPARTMENTS: i ►�ingrl�!vision ► 1 Public Works n Complete Comments: TUES/THURS ROUTING: Please Route Documents/routing slip.doc 2 -28 -02 * PERMIT COOR.o- COPY • PLAN REVIEW /ROUTING SLIP REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: � nit 1'l Fire Prevention Structural Incomplete Structural Review Required DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 07 -17-08 DATE: Planning Division Permit Coordinator Not Applicable Pert lit Ce ` , ; . t: { .p ro INCOMPLETE LETTER MAILED: ~ LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ❑ No further Review Required DUE DATE: 08-14 -08 Approved Approved with Conditions ❑ Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit, llse!dify f Kam. Ea ' s ' CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: M08 -114 DATE: 06 -13 -08 PROJECT NAME: WESTFIELD VANILLA BOX SITE ADDRESS: 1057 SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 After Permit Issued DEPARTMENTS: 0 • viskin Public Works Complete Comments: Please Route Documents/routing slip.doc 2-28-02 • PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP C TUES/THURS RO TING: APPROVALS R CORRECTIONS: fr421 Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete Permit Center. Use Only. • • . • • . .. • . • • INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Structural Review Required n Planning Division ❑ Permit Coordinator DUE DATE: 06 -19 -08 Not Applicable No further Review Required n REVIEWER'S INITIALS: DATE: DUE DATE: 07 -17 -08 Not Approved (attach comments) Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: � PERMITC�ORDCOpy• PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M08 -114 DATE: 04 -24 -08 PROJECT NAME: WESTFIELD VANILLA BOX SITE ADDRESS: 1057 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: 4 �,D�J 19 L- Buildin •'vision Fire eve ion E Public Works ❑ Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete C Comments: Incomplete ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTI G: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28-02 DUE DATE: 04-29-08 Not Applicable ❑ No further Review Required DATE: DATE: Planning Division DUE DATE: 05-27-08 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 1 6 - -V-0 i( 3 F P4 G136 Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 1 6 - -V-0 i( 3 F P4 G136 Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 1 6 - -V-0 i( 3 F P4 G136 Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INI S 1 6 - -V-0 i( 3 F P4 G136 ( `�- Summary of Revision: A V - e,r.er� (k,,(A t „pc c uit }j 1`Cf,�r�O►v✓\ - i'✓vN l "�'1 Received by: V S. 014,' +w REVISION NO. DATE RECEIVED STAFF INITIALS STAFF INITIALS ISSUED DATE STAFF INITIALS 2_ - 1-11 -OK Sununary of Revision: '(,vl (ice ' Summary of Revision: C f ;-rd _ '- 4 - olg Received by: 0 -ve ( >d r / REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Sununary of Revision: Received by: PROJECT NAME: PERMIT NO Mog-i■Li UGK ll� � SITE ADDRESS: tp S'1 S .0 . 1I ORIGINAL ISSUE DATE: to -‘,1-0 REVISION LOG (please print) (please print) (please print) (please print) (please print) Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 74/ /Dr Plan Check/Permit Number: / O 8 — // ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # ©Revision # 2— after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: 5 e.47 4 1 1- le Tee.., Sher6'ds ( VesH </( (/4/2i //4 Age X) Project Address: /037 Sou i C tes---► 4 1 / f Contact Person: Q4*''e -e P-- e.44.4.i cdr4 Phone Number: 8/5---44./.0 a= 8,2.a Summary of Revision: dha, e V4.1 -t. /Sox T a,-. 11 4 r • City of Tukwila Department of Community Development 6300 SouthcenterBoulevard, Suite k100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: htp: //www.ci.tukwila.wa.us /46 L • C/o ) , n 1 A e e e_ssori e 5 -raw' Se-4 fi hss s_por7 rhea r� , / 1/ / cS 64 /es /, 2 $ SAQL / U / u a /4 o-� �. -�3e. D OF TUKWItfi Sheet Number(s): "Cloud" or highlight all areas of revision includin Received at the City of Tukwila Permit Center by: Entered in Permits Plus on 1- t.(.--iK lapplicationslfor ns• applications an Iine\revision submittal Created: 5 -13 -2004 Steven M. Mullet, Mayor Steve Lancaster, Director JUL 111008 P fTCENT Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 6 1 /3/ 11 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # ©a Revision # / after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Wes e- /4 V ; 4 /05 St, L., ,/e - /'174 / Contact Person: Pe 56: c-av Phone Number: 20 4, - So L- e,e) ( Summary of Revision: lee ; se ee-_ l z a aid cal-; v r e cle„.__7 Project Name: Project Address: Sheet Number(s): —/ Created: 8-13 -2004 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: //www.ci.tukwila.wa.us Plan Check/Permit Number: Steven M. Mullet, Mayor Steve Lancaster, Director RECEIVED CITY OF TUKWILA JUN 13 7008 PERMIT CENTER "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by:, Entered in Permits Plus on CO31 471) ( `applicationslfonns- applications on Iinelrevision submittal License Information License OKITSCI959L8 Licensee Name OKITSU CONSTRUCTION INC Licensee Type CONSTRUCTION CONTRACTOR UBI 602515973 Ind. Ins. Account Id PRESIDENT Business Type CORPORATION Address 1 1428 WHITWORTH AVE S Address 2 City RENTON County KING State WA Zip 98055 Phone 2067149969 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 6/28/2005 Expiration Date 6/28/2009 Suspend Date Separation Date Parent Company Previous License OKITSC*030R3 Next License Associated License Business Owner Information Name Role Effective Date Expiration Date OKITSU, RODNEY STERLING AGENT 06/28/2005 OKITSU, RODNEY STERLING PRESIDENT 06/28/2005 Look Up a Contractor, E1ect>n or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. • Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= OKITSCI959L8 06/11/2008 SHEET METAL NOTES 1, THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL INTENT OF THE WORK. PROVIDE SHEET METAL SYSTEMS COMPLETE AND PER APPLICABLE CODES INCLUDING ALL NECESSARY OFFSETS, FITTINGS, SPECIAL RADIUS OR MITERED ELBOWS WHICH ARE REQUIRED DUE TO SPACE CONSTRAINTS OR OTHER CONDITIONS. 2. CONTRACTOR SHALL COORDINATE HIS WORK WITH THE WORK OF ALL OTHER TRADES. VERIFY ALL CLEARANCES PRIOR TO THE FABRICATI ❑N OF ANY WORK, 3. DUCTWORK SHALL NOT BE LOCATED OVER ELECTRICAL EQUIPMENT /PANELS. PROVIDE REQUIRED CLEARANCE IN FRONT OF ELECTRICAL EQUIPMENT, DUCTWORK SHALL NOT INTERFERE WITH ELECTRICAL EQUIPMENT CLEARANCE. 4, THE CON TRACTOR SHALL PROVIDE ALL MISCELLANE OUS SUPPORTING STEEL, ETC, FOR THE PROPER INSTALLATION OF ALL MECHANICAL SYSTEMS. 5, COORDINATE FLOOR, WALL, ROOF PENETRATIONS, LOUVER SIZES, PAD L❑CATI ❑NS, ETC. WITH ARCHITECTURAL TRADES. 6. THE CONTRACTOR SHALL REFER TO ARCHITECTURAL REFLECTED CEILING PLANS F ❑R EXACT L❑CATION OF GRILLES, REGISTERS, AND DIFFUSERS, 7, INSTALL MANUAL VOLUME DAMPERS AT ALL SUPPLY AIR BRANCH DUCTS T THE DIFFUSER, BRANCH RETURN AIR DUCT, EXHAUST AIR DUCT, AND OTHER L❑CATI ❑NS AS SHOWN ON PLANS. 8, PROVIDE FLEXIBLE C❑NNECTI ❑N AT DIFFUSER NECK, ALL FLEXIBLE DUCT SHALL BE INSULATED AND LIMITED TO 5' -0' IN LENGTH. 9, DUCTED EXHAUST AND RETURN GRILLES SHALL BE HARD CONNECTED, 10,C ❑ORDINATE AND PR ❑VIDE ACCESS DOORS IN HARD CEILING AREAS FOR ACCESS TO TERMINAL UNITS, BALANCING DAMPERS, TERMINAL UNIT HEATING C ❑IL PIPING, ETC, REFER TO ARCHITECTURAL DRAWINGS FOR CEILING TYPES. 11, CONTRACTORS SHALL VERIFY THERE ARE NO COMBUSTIBLES IN THE RETURN AIR PLENUM. IF COMBUSTIBLES ARE PRESENT CONTRACTOR SHALL COORDINATE WITH ARCHITECT /ENGINEER /OWNER'S REPRESENTATIVE COURSE OF ACTI ❑N (HARD DUCT RETURN SYSTEM OR ELIMINATE COMBUSTIBLES — FIREPROOF, WRAP, ETC.) 12.ALL SHEET METAL DUCT SIZES SHOWN ARE CLEAR INSIDE DIMENSI ❑NS. L /EP EP RG -1 PROVIDE AND INSTALL NEW DUCT SMOKE DETECTO IN SA /RA DUCT AS REQUIRED BY LOCAL CODE T PROVIDE FAN SHUTDOWN S -1 100 ENE MI• MIN 0 0 8 8 1 i i 1 amp 11 OA 4r; IR e . El . Emommi 1 RG A 1 CHA • PLAN SCALE: 1 /4" = 1' - 0" MECHANICAL NOTES 1, DUCT LINING IS NOT ALLOWED 1 1 2, ALL SUPPLY AIR DUCTWORK SHALL BE WRAPPED WITH 1' INSULATI ON TO MATCH EXISTING, 3, PROVIDE AND INSTALL FIRE DAMPERS WHERE DUCTS PENETRATE RATED CONSTRUCTION, ALL DUCTS PENETRATING SHAFTS (SMOKE BARRIERS) SHALL HAVE C❑MBINATI ❑N FIRE /SMOKE DAMPERS ACTIVATION OF DAMPER SHALL BE SIGNALED TO FIRE ALARM PANEL, 4, MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING, C ❑RING AND PATCHING REQUIRED FOR PROPER INSTALLATI ❑N OF THE SYSTEM, 5, PROVIDE BALANCING DAMPERS IN ALL BRANCH DUCTWORK AS REQUIRED FOR PROPER BALANCING OF THE SYSTEM, ENTIRE CONSTRUCTION SHALL CONFORM TO THE LATEST N OF N.F,P,A, SMACNA, THE LOCAL MECHANICAL CODE, RDINANCE, AND AUTHORITIES HAVING JURISDICTI ❑N, ACTOR SHALL C ❑ORDINATE INSTALL ATI ❑N OF HIS OTHER TRADES TO AV ❑ID CONFLICTS AND RING CONSTRUCT ION, N ANY PVC, PLASTIC 240 e 1 1 EP T MEIN • M1 k GENE A NOTES 1. CONTRACTORS SHALL PRO INDICATED HERE — IN TO P SYSTEM. 2. CONTRACTORS SHALL ORDINANCES AND AND MUNICIPALIT ALL NECESSARY PERFORMANCE OF NEW WORK SHAL APPROVAL OF T 3. C❑ C❑ SH ■ 6, T EDIT LOCAL 7. EACH CON WORK WITH INTERFERENCES RIALS OR 8.0 ❑NTRACT ❑R SHALL N ANY OTHER COMBUSTIBLE MA PLENUM. 9, MECHANICAL CONTRA CT ❑R SHALL C ❑ORDINATE ALL MECHANICAL EQUIPMENT ELECTRICAL REQUIREMENTS WITH ELECTRICAL CONTRACTOR PRI ❑R TO ANY EQUIPMENT PURCHASE. E RETURN AIR 10,TESTING & BALANCING — ENGAGE THE SERVICES OF AN INDEPENDENT CERTIFIED TEST AND BALANCE AGENCY THAT SPECIALIZED IN AND WHO'S BUSINESS IS LIMITED TO THE TESTING AND BALANCING OF HVAC SYSTEMS AND HYDR❑NIC SYSTEMS, THE AGENCY SELECTED SHALL BE CERTIFIED BY ASSOCIATED AIR BALANCE COUNCIL (A ABC) OR NATIONAL ENVIRONMENTAL BALANCING BUREAU (NEBB), AGENCY SHALL SUBMIT A COMPLETE REPORT BASED ON SMACNA BALANCING AND ADJUSTMENT MANUAL', THE HVAC SYSTEM SHALL BE TESTED AND BALANCED TO DEMONSTRATE THAT SPECIFIED CAPACITY AND PROPER CONTROL FUNCTIONING HAS BEEN ATTAINED. 11,START —UP FOR ALL EQUIPMENT SHALL BE CONDUCTED BY EACH MANUFACTURER'S START — UP REPRESENTATIVE. INCLUDE FINAL REPORT AND CERTIFICATE. PR ❑VIDE OWNER'S MANUAL AND TRAINING FOR MAINTENANCE PERSONNEL FOR EACH TYPE OF EQUIPMENT. 12,ALL EQUIPMENT AND COMBUSTI ❑N VENT TERMINATI ON ETC. SHALL BE INSTALLED PER MANUFACTURERS RECOMMENDATI ❑NS. VERIFY AND LOCATE EQUIPMENT BASED ON MANUFACTURERS RECOMMENDED CLEARANCES. 13,C ❑NTRACT ❑R SHALL PROVIDE RETURN AIR TRANSFER DUCTWORK FOR ALL ROOMS WITH WALLS FROM FINISHED FLOOR TO BOTTOM OF DECK. COORDINATE WALL L❑CATI ❑NS WITH ARCHITECTURAL TRADES, IDE EQUIPMENT AND SPECIALTIES ❑VIDE A COMPLETE AND WORKING C PLY WITH ALL LAWS, LOCAL CODE ❑F THE STATE, FEDERAL AGENCIES r' NTRACT ❑RS SHALL SECURE AND PAY FOR FEE AND PERMITS REQUIRED IN THE H. WORK, ALL CUTTING AND PATCHING FOR BE DONE BY THIS CONTRACTOR WITH THE E OWNER'S REPRESENTATIVE. CONTRACTOR HALL VISIT THE SITE AND CHECK THE EXISTING NDITT❑ BEF ORE SUBMISSI ❑N OF BIDS. NO ALLOWANCE A ■ E MADE IN BEHALF OF EXTRA EXPENSES DUE T THE LURE TO MAKE SUCH AN EXAMINATION. 4, CONTRACTOR SHALL PROVIDE A COMPLETED OPERABLE SYSTEM AS HERE —IN DESCRIBED. IF THE DOCUMENTATION IS UNCLEAR OR INCOMPLETE TO THE CONTRACTOR HE SHALL S❑ STATE IN WRITING TO THE OWNER'S REPRESENTATIVE /ENGINEER AND REQUEST CLARIFICATION ON THOSE ITEMS REQUIRING CLARIFICATI ❑N. IF NO SUCH STATEMENT IS MADE IT SHALL BE PRESUMED THAT THE CONTRA CT ❑R FULLY UNDERSTANDS THE INTENT OF A FUNCTION OF THE SYSTEM DESCRIBED, 5, ANY CLAIMS FOR ADDITIONAL SERVICES BASED UPON UNDERSTANDING OF THE SYSTEMS WILL NOT BE ALLOWED. C ONTRACT DRAWINGS ARE DIAGRAMMATIC AND INTENDED TO CONVEY THE SC OPE OF WORK AND GENERAL ARRANGEMENT OF EQUIPMENT. D❑ NOT SCALE DRAWINGS, 6, CONTRACTOR SHALL COORDINATE HIS W❑RK WITH ALL OTHER TRADES, CONTRACTOR SHALL SECURE FINAL OCCUPANCY INSPECTION AND SUBMIT CERTIFICATES TO THE OWNER'S REPRESENTATIVE, CONTRACTOR SHALL FURNISH THE OWNER WITH A WRITTEN GUARANTEE TO CORRECT ALL IMPERFECTI ❑NS IN MATERIALS AND WORKMANSHIP, WHICH MAY DEVELOP IN THE SYSTEMS INSTALLED AND UNDER NORMAL USE FOR A PERI ❑D OF ONE YEAR AFTER FINAL ACCEPTANCE BY THE OWNER. 7. BASE BID FOR EQUIPMENT IS TO BE UNITS SCHEDULED. PRICING USING ALTERNATE ACCEPTED AND LISTED MANUFACTURES SHALL STATE ALTERNATE MANUFACTURER AND MODEL NUMBER AS PART OF BID, VOLUNTARY ALTERNATES FOR EQUIPMENT NOT LISTED SHALL ONLY BE WITH WRITTEN ACCEPTANCE OF THE ENGINEER PRI ❑R TO BIDDING. VOLUNTARY ALTERNATES WILL NOT BE REVIEWED FOR ACCEPTANCE BY THE ENGINEER DURING THE 7 DAYS PRI ❑R TO BID DATE. 8, CONTRACTOR SHALL PR ❑VIDE, STORE, PLACE AND INSTALL ALL NECESSARY EQUIPMENT REQUIRED. ALL EQUIPMENT SHALL BE INSTALLED PER THE MANUFACTURER'S RECOMMENDATIONS AND IN SUCH A MANNER AS TO FUNCTI ❑N IN ITS INTENDED USE, 8, CONTRACTOR SHALL SUBMIT SUBMITTALS F ❑R ALL EQUIPMENT AND MATERIALS FOR REVIEW PRIOR TO PURCHASE. 9. AFTER INSTALL ATI ❑N IS COMPLETE, CONTRACTOR SHALL BE RESPONSIBLE FOR STARTUP, INSPECTORS' APPROVAL AND CLEAN UP. CONTROLS NOTE FMB CONTROLS SHALL MATCH MALL CONTR OLS SYSTEM, CONTROLS CONTRACT OR SHALL TIE — INTO EXISTING CONTR OLS FOR ❑PERATI ❑N, MECHANICAL KEYED NOTES: (MECHANICAL KEYED NOTES APPLY TO THIS SHEET ONLY) 1 CONNECT TO EXISTING SUPPLY AIR MAIN (VERIFY IN FIELD). CONNECT EXHAUST FROM TOILET EXHAUST FAN TO MALL EXHAUST DUCT MAIN (VERIFY IN FIELD). MECHANICAL SYMBOL LEGEND: NOTE; THE F ❑LL ❑WING SYMBOLS SHALL BE AS INDICATED, UNLESS NOTED OTHERWISE ON PLANS, x SD -1. 24 °x24' SUPPLY DIFFUSER RG -1+ 24'x24' RETURN GRILLE Q THERMOSTAT I DUCT FLEX CEILING MOUNTED INLINE EXHAUST FAN, 9 Nc REVIEWED FOR CODE COMPLIANCE APPROVED JUN 1 9 2008 Cif Of Tukwila BUILDIN .:' 11. ION Permit No. By Date: E L Cr4P7ii City o•' Tukwila RECEIVED JUN 132008 PERMIT CAR REVISION N0:1 MO9 11� 0 1057 Southcenter Mall Tukwila, WA 98188 smith cc 1725 westlake ave. n. suite 210 seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith @smithco.org http: / /www.smithco.org/ Consultant Consultant Registration REVISiONS ! -I es n e `Je !?'1c7�. t0 tf'1•• t'nt'+ra of �V )ri( t;'1 +ithout prior approval of shall Tukwila Building Division. C' ; _ E:: Revisions will require a new plan submit!al and may include additional plan review fees. Issues and Revisions No. Date 1 03.31.08 2 05.05.08 3 05.28.08 4 05.29.08 Plar revivf approval is sailed to err= and omfssi "°3 Approval of construction documents does not authorize) the violation of any adopted code or ord nancv. s Of approved R s Copy and Condit od la i '' o ylou;: BUILDING DI VISII Project Number 02008018.00 Scale Template AS NOTED 4.3 (120101) M -1 6294 Description MECHANICAL PLAN Computer File CW05- 2008— M1.DWG Architect Registration Issues By Check PERMIT KLS PERMIT CORRECTIONS KLS ISSUE KLS CONSTRUCTION SET KLS Project Name WESTFIELD SOUTHCENTER MALL All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. IIc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. IIc. SHEET METAL NOTES • 1. THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL INTENT OF THE WORK, PR ❑VIDE SHEET METAL SYSTEMS COMPLETE AND PER APPLICABLE CODES INCLUDING ALL NECESSARY OFFSETS, FITTINGS, SPECIAL RADIUS OR MITERED ELBOWS WHICH ARE REQUIRED DUE TO SPACE CONSTRAINTS OR EITHER CONDITIONS, 2. CONTRACTOR SHALL COORDINATE HIS WORK WITH THE WORK OF ALL OTHER TRADES. VERIFY ALL CLEARANCES PRIOR TO THE FABRICATION OF ANY WORK. 3. DUCTWORK SHALL NOT BE LOCATED OVER ELECTRICAL EQUIPMENT /PANELS. PROVIDE REQUIRED CLEARANCE IN FRONT OF ELECTRICAL EQUIPMENT, DUCTWORK SHALL NOT INTERFERE WITH ELECTRICAL EQUIPMENT CLEARANCE, 4, THE CONTRACTOR SHALL PR ❑VIDE ALL MISCELLANE ❑US SUPPORTING STEEL, ETC. FOR THE PROPER INSTALLATION OF ALL MECHANICAL SYSTEMS. 5. COORDINATE FLOOR, WALL, ROOF PENETRATIONS, LOUVER SIZES, PAD L ❑CATIONS, ETC. WITH ARCHITECTURAL TRADES, 6, THE CONTRACTOR SHALL REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF GRILLES, REGISTERS, AND DIFFUSERS. 7. INSTALL MANUAL VOLUME DAMPERS AT ALL SUPPLY AIR BRANCH DUCTS TO THE DIFFUSER, BRANCH RETURN AIR DUCT, EXHAUST AIR DUCT, AND OTHER LOCATIONS AS SHOWN ON PLANS. 8. PR ❑VIDE FLEXIBLE C❑NNECTI ❑N AT DIFFUSER NECK. ALL FLEXIBLE DUCT SHALL BE INSULATED AND LIMITED TO 5' -0° IN LENGTH. 9,DUCTED EXHAUST AND RETURN GRILLES SHALL BE HARD CONNECTED, 10,C❑❑RDINATE AND PR ❑VIDE ACCESS DOORS IN HARD CEILING AREAS FOR ACCESS TO TERMINAL UNITS, BALANCING DAMPERS, TERMINAL UNIT HEATING COIL PIPING, ETC, REFER TO ARCHITECTURAL DRAWINGS FOR CEILING TYPES. 11. CONTRACTORS SHALL VERIFY THERE ARE NO COMBUSTIBLES IN THE RETURN AIR PLENUM, IF COMBUSTIBLES ARE PRESENT CONTRACTOR SHALL COORDINATE WITH ARCHITECT /ENGINEER /OWNER'S REPRESENTATIVE COURSE OF ACTI ❑N (HARD DUCT RETURN SYSTEM OR ELIMINATE COMBUSTIBLES - FIREPR❑ ❑F, WRAP, ETC.) 12.ALL SHEET METAL DUCT SIZES SHOWN ARE CLEAR INSIDE DIMENSIONS. 2 PROVIDE AND INSTALL NEW DUCT SMOKE DETECTOR IN 4; /RA DUCT AS REQUIRED BY LOCAL CODE Td PROVIDE FAN SHUTDOWN 0 , RG 0 . 0- w MECHANICAL NOTES 1, DUCT LINING IS NOT ALLOWED FMB - 2-00 1 2. ALL SUPPLY AIR DUCTWORK SHALL BE WRAPPED WITH 1' INSULATI ❑N TO MATCH EXISTING, 5, PROVIDE BALANCING DAMPERS IN ALL BRANCH DUCTWORK AS REQUIRED FOR PROPER BALANCING OF THE SYSTEM. 6. THE ENTIRE CONSTRUCTION SHALL CONFORM TO THE LATEST EDITI ❑N OF N,F,P,A, SMACNA, THE MICHIGAN MECHANICAL CODE, LOCAL ORDINANCE, AND AUTHORITIES HAVING JURISDICTI ❑N. 7, EACH CONTRACTOR SHALL COORDINATE INSTALLATI ❑N OF HIS WORK WITH ALL OTHER TRADES TO AVOID CONFLICTS AND INTERFERENCES DURING CONSTRUCTION. 3. PR ❑VIDE AND INSTALL FIRE DAMPERS WHERE DUCTS PENETRATE RATED C❑NSTRUCTI ❑N. ALL DUCTS PENETRATING SHAFTS (SMOKE BARRIERS) SHALL HAVE C❑MBINATI ❑N FIRE /SMOKE DAMPERS ACTIVATI ❑N OF DAMPER SHALL BE SIGNALED TO FIRE ALARM PANEL. 4, MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING, CORING AND PATCHING REQUIRED FOR PROPER INSTALLATION OF THE SYSTEM, 8. CONTRACTOR SHALL NOT RUN ANY PVC, PLASTIC MATERIALS OR ANY OTHER COMBUSTIBLE MATERIAL INSIDE THE RETURN AIR PLENUM. 9,MECHANIGAL CONTRACTOR SHALL COORDINATE ALL MECHANICAL EQUIPMENT ELECTRICAL REQUIREMENTS WITH ELECTRICAL CONTRACTOR PRI ❑R TO ANY EQUIPMENT PURCHASE. 10,TESTING & BALANCING - ENGAGE THE SERVICES OF AN INDEPENDENT CERTIFIED TEST AND BALANCE AGENCY THAT SPECIALIZED IN AND WHO'S BUSINESS IS LIMITED TO THE TESTING AND BALANCING OF HVAC SYSTEMS AND HYDR❑NIC SYSTEMS, THE AGENCY SELECTED SHALL BE CERTIFIED BY ASSOCIATED AIR BALANCE COUNCIL (AABC) OR NATIONAL ENVIRONMENTAL BALANCING BUREAU (NEBB), AGENCY SHALL SUBMIT A COMPLETE REPORT BASED ON SMACNA 'BALANCING AND ADJUSTMENT MANUAL'. THE HVAC SYSTEM SHALL BE TESTED AND BALANCED TO DEMONSTRATE THAT SPECIFIED CAPACITY AND PROPER CONTROL FUNCTIONING HAS BEEN ATTAINED. 11. START-UP FOR ALL EQUIPMENT SHALL BE CONDUCTED BY EACH MANUFACTURER'S START-UP REPRESENTATIVE. INCLUDE FINAL REPORT AND CERTIFICATE, PR ❑VIDE OWNER'S MANUAL AND TRAINING FOR MAINTENANCE PERSONNEL FOR EACH TYPE OF EQUIPMENT. 12,ALL EQUIPMENT AND COMBUSTION VENT TERMINATI ❑N ETC, SHALL BE INSTALLED PER MANUFACTURERS REC❑MMENDATI ❑NS, VERIFY AND LOCATE EQUIPMENT BASED ON MANUFACTURERS RECOMMENDED CLEARANCES. 13,C❑NTRACT ❑R SHALL PR ❑VIDE RETURN AIR TRANSFER DUCTWORK FOR ALL ROOMS WITH WALLS FROM FINISHED FLOOR TO BOTTOM OF DECK. COORDINATE WALL L❑CATI ❑NS WITH ARCHITECTURAL TRADES, GENERAL NOTES 1. CONTRACTORS SHALL PR ❑VIDE EQUIPMENT AND SPECIALTIES INDICATED HERE -IN TO PR ❑VIDE A COMPLETE AND WORKING SYSTEM. PER 2006 IMC SECTION 606 Install smoke detector to shut down air distribution by VAV's when the total combined C F M of all VAV's (to include other tenants) sharing the same plenum space exceeds 2000 CFM. (See IMC 606.2.2 for approved method of detection) /7% 2, CONTRACTORS SHALL COMPLY WITH ALL LAWS, LOCAL ORDINANCES AND CODES OF THE STATE, FEDERAL AGENCIES AND MUNICIPALITY. CONTRACTORS SHALL SECURE AND PAY FOR ALL NECESSARY FEES AND PERMITS REQUIRED IN THE PERFORMANCE OF HIS WORK, ALL CUTTING AND PATCHING FOR NEW WORK SHALL BE DONE BY THIS CONTRACTOR WITH THE APPROVAL OF THE OWNER'S REPRESENTATIVE, 3. CONTRACTOR SHALL VISIT THE SITE AND CHECK THE EXISTING CONDITIONS BEFORE SUBMISSI ❑N OF BIDS. NO ALLOWANCE SHALL BE MADE IN BEHALF OF EXTRA EXPENSES DUE TO THE FAILURE TO MAKE SUCH AN EXAMINATI ❑N. 4. CONTRACTOR SHALL PROVIDE A COMPLETED OPERABLE SYSTEM AS HERE -IN DESCRIBED, IF THE DOCUMENTATION IS UNCLEAR OR INCOMPLETE TO THE CONTRACTOR HE SHALL S❑ STATE IN WRITING TO THE OWNER'S REPRESENTATIVE /ENGINEER AND REQUEST CLARIFICATI ❑N ON THOSE ITEMS REQUIRING CLARIFICATION. IF NO SUCH STATEMENT IS MADE IT SHALL BE PRESUMED THAT THE CONTRACTOR FULLY UNDERSTANDS THE INTENT OF A FUNCTION OF THE SYSTEM DESCRIBED. 5. ANY CLAIMS FOR ADDITIONAL SERVICES BASED UPON UNDERSTANDING OF THE SYSTEMS WILL NOT BE ALLOWED. CONTRACT DRAWINGS ARE DIAGRAMMATIC AND INTENDED TO CONVEY THE SCOPE OF WORK AND GENERAL ARRANGEMENT OF EQUIPMENT. D❑ NOT SCALE DRAWINGS. 6. CONTRACTOR SHALL COORDINATE HIS WORK WITH ALL OTHER TRADES. CONTRACTOR SHALL SECURE FINAL OCCUPANCY INSPECTION AND SUBMIT CERTIFICATES TO THE OWNER'S REPRESENTATIVE. CONTRACTOR SHALL FURNISH THE OWNER WITH A WRITTEN GUARANTEE TO CORRECT ALL IMPERFECTI ❑NS IN MATERIALS AND WORKMANSHIP, WHICH MAY DEVELOP IN THE SYSTEMS INSTALLED AND UNDER NORMAL USE FOR A PERIOD OF ONE YEAR AFTER FINAL ACCEPTANCE BY THE OWNER. 7, BASE BID FOR EQUIPMENT IS TO BE UNITS SCHEDULED. PRICING USING ALTERNATE ACCEPTED AND LISTED MANUFACTURES SHALL STATE ALTERNATE MANUFACTURER AND MODEL NUMBER AS PART OF BID, VOLUNTARY ALTERNATES FOR EQUIPMENT NOT LISTED SHALL ONLY BE WITH WRITTEN ACCEPTANCE OF THE ENGINEER PRI ❑R TO BIDDING. VOLUNTARY ALTERNATES WILL NOT BE REVIEWED FOR ACCEPTANCE BY THE ENGINEER DURING THE 7 DAYS PRIOR TO BID DATE. 8, CONTRACTOR SHALL PROVIDE, STORE, PLACE AND INSTALL ALL NECESSARY EQUIPMENT REQUIRED. ALL EQUIPMENT SHALL BE INSTALLED PER THE MANUFACTURER'S RECOMMENDATIONS AND IN SUCH A MANNER AS TO FUNCTI ❑N IN ITS INTENDED USE, 8. CONTRACTOR SHALL SUBMIT SUBMITTALS FOR ALL EQUIPMENT AND MATERIALS FOR REVIEW PRI ❑R TO PURCHASE, 9, AFTER INSTALLATI ❑N IS COMPLETE, CONTRACTOR SHALL BE RESPONSIBLE FOR STARTUP, INSPECTORS' APPROVAL AND CLEAN UP. ° //%O.%/ � SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical g Electrical giPlumbing IV Gas Piping City of Tukwila BUILDING DIVISION MECHANICAL KEYED NOTES: (MECHANICAL KEYED NOTES APPLY TO THIS SHEET ONLY) 11 CONNECT TO EXISTING SUPPLY AIR MAIN (VERIFY IN FIELD), U CONNECT EXHAUST FROM TOILET EXHAUST FAN TO MALL EXHAUST DUCT MAIN (VERIFY IN FIELD). MECHANICAL SYMBOL LEGEND: NOTE: THE FOLL ❑WING SYMBOLS SHALL BE AS INDICATED, UNLESS NOTED OTHERWISE ON PLANS. x SD -11 24 °x24° SUPPLY DIFFUSER RG -1: 24 °x24° RETURN GRILLE Q THERMOSTAT 1v,i DUCT FLEX CEILING MOUNTED INLINE EXHAUST FAN. FILE OPY Permit No. Piar review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Reteipt of approved Fie. • , . and conditions is . j o !ed ed: By City of Tu kwila BUILDING DIVLSIO REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. CONTROLS NOTE FOR ❑PERATI ❑N, FMB CONTROLS SHALL MATCH MALL CONTROLS SYSTEM. - -- °""°°` CONTROLS CONTRACTOR SHALL TIE -INTO EXISTING C ❑NTROLSW�O t� ��� ' I " U � 1057 Southcenter Mall Tukwila, WA 98188 smith co. 1725 westlake ave. n. suite 210 seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith @smithco.org http: / /www.smithco.org/ Consultant Consultant Registration Issues and Revisions No. Date 03.31.08 Issues By Check PERMIT 6294 Architect Registration KLS RECEIVED CITY OF TUKWILA APR 2 4 2008 PERMIT CENTER AN Project Name WESTFIELD SOUTHCENTER MALL Project Number 02008018.00 Description MECHANICAL PLAN Computer File CW05- 2008— M1,DWG Scale AS NOTED Template 4.3 (12 0101) All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. IIc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written pemiission of smith co. IIc. M - FAN POWERED VARIABLE AIR VOLUME BOX SCHEDULE MARK FMB -1 FMB -2 FMB-3 FMB-4 FMB -5 INLET SIZE 6 "0 81 2) 10 "0 12 "0 14 "0 PRIMARY AIR CFM RANGE: MINIMUM 80 145 230 325 450 MAXIMUM 500 900 1400 2000 3000 DESIGN PRIMARY AIR FLOW (MAXIMUM COOLING CFM) SEE PLAN SEE PLAN SEE PLAN SEE PLAN SEE PLAN MINIMUM DESIGN PRIMARY AIR INLET S.P. (in. w.g.) 0.5" 0.5" 0.5" 0.5" 0.5" FAN DESIGN AIR FLOW (CFM) 300 500 700 950 1500 MINIMUM DOWNSTREAM S.P. (in. w.g.) (FAN S.P.) 0.5" 0.5" 0.5" 0.5" 0.5" NC DISCHARGE @ PRIMARY AIR A PS =1.5" 15 20 22 26 26 REHEAT COIL: TYPE ELECTRIC ELECTRIC ELECTRIC ELECTRIC ELECTRIC KW 3.0 5.0 10.0 15.0 15.0 VOLT /PHASE 277/10 277/10 480/30 480/30 480/30 ELECTRICAL DATA: HP 1/6 1/4 1/4 1/3 1/3 VOLT /PHASE 277/10 277/10 277/10 277/10 277/10 F.L.A. 0.8 1.4 1.4 3.0 3.0 BASED ON: MANUFACTURER TITUS TITUS TITUS TITUS TITUS DTFS DTFS SIZE B DTFS SIZE C DTFS SIZE C DTFS SIZE D DTFS SIZE 0 APPLICABLE NOTES 1,2,3,4,5,6,7 1,2,3,4,5,6,7 1,2,3,4,5,6,7 1,2,3,4,5,6,7 1,2,3,4,5,6,7 AIR DEVICE SCHEDULE MARK DESCRIPTION SIZE MAXIMUM CFM MAX. P.D'.' (in. w.g.) MAXIMUM NC LEVEL BASED ON APPLICABLE NOTES MANUFACTURER MODEL SD -1 SQUARE LOUVER FACED CEILING DIFFUSER 24 "x24" SEE CAPACITY SCHEDULE 0.1" 30 TITUS TMSA 1, 2, 3 SR -1 WALL AND /OR DUCT MOUNTED SUPPLY REGISTER, DOUBLE DEFLECTION SEE PLANS SEE PLANS 0.1" 30 TITUS 300RL 1, 3, 4 RG -1 EGGCRATE RETURN GRILLE SEE PLANS SEE PLANS 0.1" 30 TITUS 50F 1, 3, 4 EG -1 EGGCRATE EXHAUST GRILLE 12 "x12" SEE PLANS 0.1" 30 TITUS 50F 1, 2, 3, 4 FAN SCHEDULE MARK EF -1 SERVES RESTROOM LOCATION CEILING TYPE CEILING CFM 100 EXTERNAL STATIC PRESSURE (in. w.g.) 0.6" ELECTRICAL DATA DRIVE DIRECT HP 80 WATTS VOLTS /PHASE 115/10 FAN RPM 950 BASED ON: MANUFACTURER GREENHECK MODEL SP -B110 APPLICABLE NOTES 1, 2 AIR DEVICE CAPACITY SCHEDULE MARK CFM RANGE FACE SIZE (inches) SR -1 (272 RL) 0 - 135 6'x6" 136 - 240 10 "x6" 241 - 340 14 "x6" 341 - 450 18'x6" 451 - 775 18 "x10" AIR DEVICE CAPACITY SCHEDULE MARK CFM RANGE NECK SIZE (inches) SD -1 0 - 250 8 "0 251 - 425 10 "0 426 - 700 12 "0 701 - 1000 14 "0 AIR DEVICE NOTES: 1. DESIGN CFM AS NOTED ON PLANS. 2. SEE AIR DEVICE CAPACITY SCHEDULE FOR NECK SIZE. DUCT SIZE TO DIFFUSER/REGISTER /GRILLE SHALL BE EQUAL TO NECK NECK SIZE, UNLESS OTHERWISE NOTED. 3. PROVIDE MOUNTING FRAME AND BORDER STYLE TO ACCOMMODATE THE ARCHITECT'S REFLECTED CEILING PLAN AND /OR WALL CONSTRUCTION. 4. PROVIDE VOLUME DAMPER. 5. RETURN, EXHAUST, AND TRANSFER GRILLES SHALL BE 24 "x24 ", UNLESS OTHERWISE NOTED ON PLANS. FAN MIXING BOX PLAN INFORMATION: REHEAT COIL MAXIMUM DESIGN PRIMARY AIR CFM OTHERWISE NOTED MIN. STOP @ ( )% OF DESIGN PRIMARY AIR CFM «FAN MIXING BOXES ARE ALSO AVAILABLE IN 208 -240 VOLTS AND 277 VOLTS. THE FLA WILL CHANGE ACCORDINGLY. SEE CATALOG FOR CHANGES. »» 6. PROVIDE WITH MODULINEAR DIFFUSER PLENUM. 7. TRANSFER GRILLES ON PLANS INDICATED BY TG -1 (XX "0) SHALL BE PROVIDE WITH A RECTANGULAR TO ROUND NECK ADAPTER. 8. ALL AIR DEVICES SHALL HAVE OFF -WHITE FINISH UNLESS OTHERWISE NOTED. FAN MIXING BOX NOTES: 1. FURNISH WITH 1" THROWAWAY FILTERS, INTAKE PLENUM, HANGER RODS, AND SINGLE POINT POWER CONNECTION. 2. DESIGN PRIMARY COOLING AIR CFM MINIMUM STOP @ 33% OF DESIGN PRIMARY COOLING AIR, FOR ALL EXPOSURES OTHER THAN NORTH (USE 66% FOR NORTH). 3. PROVIDE DISCONNECTS. STARTER MOUNTED AT THE UNIT SUITABLE FOR THE MOTOR HORSEPOWER. 4. DDC BOX CONTROLLER TO BE FURNISHED BY T.C.C. TO THE BOX MANUFACTURER, TO BE INSTALLED AS FACTORY. FIELD CONTROL WIRING AND CONTROL TRANSFORMER BY T.C.C. 5. CONTRACTOR SHALL NUMBER ALL FAN MIXING BOXES, SO THAT EACH BOX HAS AN UNIQUE NUMBER. COORDINATE NUMBERING SYSTEM WITH ELECTRICAL TRADES. 6. FOR THOSE FMB BOXES, WHICH AT THIS TIME ARE NOT PROVIDED WITH THERMOSTAT LOCATIONS AND SUPPLY AIR DUCTWORK, PROVIDE 50' -0" OF CONTROL WIRING/TUBING AND THERMOSTAT COILED UP AT FMB BOX. 7. PROVIDE INLET AIR PROVING SWITCH TO PROTECT ELECTRICAL REHEAT COIL. FAN NOTES: 1. PROVIDE DISCONNECT. 2. PROVIDE THE FOLLOWING ACCESSORIES: A. DESIGNER GRILLE. B. BACKDRAFT DAMPER. C. MOUNTING BRACKETS. CEILING RECTANGULAR SUPPLY DUCT NOT TO SCALE MOI -- I (�I 45" CLINCH COLLAR OR ROUND SPIN -IN FITTING CONNECTION WITH MANUAL VOLUME DAMPER AND LOCKING QUADRANT. (SEE PLAN) TRANSITION TO ROUND OR ROUND DUCT SAME AS DIFFUSER NECK UNLESS NOTED OTHERWISE. (SEE PLAN) MAX. 5' -0" LONG (EXTENDED) ROUND FLEXIBLE DUCT CONNECTION SAME AS DIFFUSER NECK DIA. (1 -90" BEND. MAX.) CEILING DIFFUSER (SEE PLAN) STANDARD DIFFUSER AND DUCT CONNECTION DETAIL MANUAL AIR VOLUME DAMPER W/ LOCKING QUADRANT (TYPICAL) TRANSITION TO ROUND WHEN REQUIRED (SEE PLAN) r � CLAMP (TYP) MA`f 5 200% City Df tukvuila BUILDING DIVI C RECEIVED CITY OF TUKWILA APR 2 4 2008 PERMIT CENTER 1057 Southcenter Mall Tukwila, WA 98188 smith co. 1725 westlake ave. n. suite 210 seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith @smithco.org http://www.smithco.org/ Consultant Consultant Registration Issues and Revisions No. Date 1 03.31.08 RE`+IEW CODE C0M APPRO \ Project Name WESTFIELD SOUTHCENTER MALL Project Number Description Computer File 02006088.00 Issues GENERAL INFORMATION CW05- 2008- T1.DWG Scale AS NOTED Template 4.3 (120101) Architect Registration By Check PERMIT KLS All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. 11c. M -2 MECHANICAL SPECIFICATIONS 15010: GENERAL PROVISIONS: (THE WORD "CONTRACTOR" IN THIS ACTION SHALL REFER TO TENANTS PLUMBING, FIRE SPRINKLER AND HVAC MECHANICAL CONTRACTORS). A. GENERAL 1. THE GENERAL CONDITIONS OF THE CONTRACT, CURRENT EDITION PUBLISHED IN STANDARD FORM BY AMERICAN INSTITUTE OF ARCHITECTS, SHALL BE PART OF THIS CONTRACT. 2. THE ARTICLES CONTAINED IN THIS DIVISION AND IN ARCHITECTURAL SPECIFICATIONS MAY AMEND, MODIFY, SUPERSEDE, VOID OR SUPPLEMENT THE ARTICLES OF THE GENERAL CONDITIONS NOTED IN PARAGRAPH 15010(A) ABOVE, AND SHALL TAKE PRECEDENCE OVER THE PROVISIONS OF THE GENERAL CONDITIONS IN 15010(A). 3. THIS CONTRACTOR 15 REFERRED TO THE ARCHITECTURAL, STRUCTURAL AND ELECTRICAL PLANS AND SPECIFICATIONS WHICH ARE HEREBY MADE PART OF THE CONTRACT. 4. THIS CONTRACTOR SHALL TAKE OUT ALL NECESSARY PERMITS, LICENSES AND CERTIFICATES AND PAY ALL FEES CONNECTED THEREWITH. 5. BIDDERS SHALL VISIT THE SITE AND FAMILIARIZE THEMSELVES, WITH ALL CONDITIONS SURROUNDING THE WORK PRIOR TO SUBMITTING THE BID. 6. DRAWINGS ARE DIAGRAMMATIC AND INTENDED TO SHOW APPROXIMATE LOCATIONS UNLESS SPECIFICALLY DIMENSIONED. COORDINATE THE WORK WITH THE OTHER TRADES TO AVOID INTERFERENCE. SHOULD MECHANICAL WORK BE INSTALLED SUCH THAT IT INTERFERES WITH THE WORK OF OTHER CONTRACTORS, SUCH WORK SHALL BE REDONE AT NO ADDITIONAL COST TO TENANT. 7. AT THE COMPLETION OF THE WORK THIS CONTRACTOR SHALL REMOVE ALL RUBBISH, DIRT AND STAINS CAUSED BY HIS WORK AND SHALL THOROUGHLY CLEAN ALL MECHANICAL WORK INCLUDING EQUIPMENT, FIXTURES, DUCTWORK, PIPING, APPLIANCES, ETC. 8. THIS CONTRACTOR SHALL TOUCH UP OR REFINISH THE FACTORY FINISH OF EQUIPMENT MARRED DURING SHIPMENT OR INSTALLATION. 9. THIS CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR SUCH EQUIPMENT AND MATERIAL AS THE OWNER MAY REQUIRE FOR HIS REVIEW. THE OWNERS REVIEW MUST TAKE PLACE BEFORE CONSTRUCTION BEGINS. 10. "RECORD" DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR IF INSTALLATION DEVIATES FROM THE ORIGINAL LAYOUT. 11. MOTORS SHALL BE DESIGNED FOR SUPPLY VOLTAGES AS SCHEDULED AND SHALL COMPLY WITH AIEE AND NEMA REQUIREMENTS. PROVIDE ACROSS THE LINE STARTERS AN ALL MOTOR UNLESS NOTED OTHERWISE. MOTORS 1.0 HP AND LARGER SHALL BE HIGH EFFICIENCY. B. CODES ALL WORK SHALL CONFORM TO ALL NATIONAL, STATE, COUNTY, CITY, HEALTH AND SAFETY AND ENERGY CODES THAT APPLY, AS WELL AS WITH ALL LANDLORD CRITERIA. THIS CONTRACTOR SHALL INQUIRE INTO AND COMPLY WITH ALL APPLICABLE CODES, ORDINANCES, AND REGULATIONS. THIS CONTRACTOR SHALL INCLUDE ANY CHANGES REQUIRED BY CODES IN THE BID AND IF THESE CHANGES ARE NOT INCLUDED IN THE BID, THEY MUST BE QUALIFIED AS A SEPARATE LINE ITEM IN THE BID. AFTER CONTRACT IS ISSUED, NO ADDITIONAL COST DUE TO CODE ISSUES SHALL BE REIMBURSED TO THE CONTRACTOR, C. TRADE NAMES, MANUFACTURERS AND SHOP DRAWINGS WHERE TRADE NAMES AND MANUFACTURES ARE USED ON THE DRAWINGS OR IN THE SPECIFICATIONS, THE EXACT EQUIPMENT SHALL BE USED AS A MINIMUM FOR THE BASE BID. MANUFACTURES CONSIDERED AS AN EQUAL OR BETTER IN AT ASPECTS TO THAT SPECIFIED WILL BE SUBJECT TO APPROVAL IN WRITING BY CLIENT'S PROJECT MANAGER OR ENGINEER THROUGH SHOP DRAWING SUBMITTAL PROCESS FOR ACCEPTANCE PRIOR TO EQUIPMENT BEING ORDERED. IF THE MECHANICAL CONTRACTOR WISHES TO SUBMIT ON ALTERNATE EQUIPMENT, THE CONTRACTOR SHALL SUPPLY CUT SHEETS DESCRIBING DIMENSIONAL DATA, UNITS OPERATING WEIGHTS AND ELECTRICAL CHARACTERISTICS TO THE ENGINEER. IN ADDITION, CONTRACTOR WILL SUPPLY ENGINEER WITH COMPUTER GENERATED PERFORMANCE DATA FROM CONTRACTORS EQUIPMENT REPRESENTATIVE FOR ALTERNATE EQUIPMENT. PERFORMANCE DATA SHALL BE CALCULATED FROM DESIGN CONDITIONS LISTED ON THE EQUIPMENT SCHEDULES. THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ADDITIONAL COSTS INCURRED BY OTHER CONTRACTORS AS A RESULT OF USING EQUIPMENT NOT SPECIFIED OR SCHEDULED. EXAMPLES WOULD BE LARGER WIRE OR CIRCUIT BREAKER SIZES OR ADDITIONAL STRUCTURAL SUPPORT. THE USE OF ANY UNAUTHORIZED EQUIPMENT SHALL BE SUBJECT TO REMOVAL AND REPLACEMENT AT THE CONTRACTS EXPENSE. 15020 DEMOLITION: A. REMOVE ALL PIPING, DUCTWORK AND EQUIPMENT NOT BEING REUSED. PIPING AND ACCESSORIES ASSOCIATED WITH EQUIPMENT BEING REMOVED, BUT NOT NECESSARILY NOTED ON DRAWINGS, SHALL ALSO BE REMOVED. B. EQUIPMENT AND MATERIALS BEING REMOVED SHALL REMAIN THE PROPERTY OF THE OWNER. THE OWNER SHALL INDICATE WHICH ITEMS IF ANY ARE TO BE RETAINED. ITEMS TO BE SALVAGED SHALL BE MOVED TO A STORAGE AREA THAT IS DESIGNATED BY THE OWNER. ALL OTHER MATERIALS AND EQUIPMENT, NOT WANTED BY THE OWNER, SHALL BE REMOVED FROM THE SITE AND BE PROPERLY DISPOSED OF. C. WHERE EXISTING WALLS, FLOORS OR OTHER PORTIONS OF THE BUILDING REQUIRE PATCHING AFTER REMOVAL OF MATERIAL OR EQUIPMENT, THE PATCHING SHALL BE THE RESPONSIBILITY OF THIS CONTRACTOR. D. NO ASBESTOS WORK OF ANY NATURE SHALL BE PERFORMED BY THE CONTRACTOR PURSUANT TO THIS CONTRACT. IF DURING THE CONSTRUCTION OF THIS PROJECT, WORK INVOLVING ASBESTOS IS SUSPECTED OR ENCOUNTERED, PROMPTLY NOTIFY THE OWNER, AND THE OWNER, WITH HIS OWN FORCES OR BY SEPARATE CONTRACT SHALL BE RESPONSIBLE FOR COMPLETE REMOVAL AND DISPOSITION OF THE ASBESTOS. IF THE CONTRACTOR CLAIMS THAT DELAY AND ADDITIONAL COST IS INVOLVED BECAUSE OF THIS ACTION, HE SHALL MAKE CLAIM AS PROVIDED ELSEWHERE IN THE CONTRACT DOCUMENTS. 15400 PLUMBING: (THE WORD CONTRACTOR IN THIS SECTION SHALL REFER TO TENANTS PLUMBING CONTRACTOR.) A. SCOPE UNLESS NOTED OTHERWISE, THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS AND EQUIPMENT FOR THE INSTALLATION OF A COMPLETE AND TENANT ACCEPTABLE OPERATING PLUMBING SYSTEM HEREIN DESCRIBED INCLUDING: HOT AND COLD WATER SYSTEMS, CONNECTION TO EXISTING SANITARY SEWER SYSTEMS, PLUMBING FIXTURES, MISCELLANEOUS PLUMBING AND INSULATION. B. MATERIALS UNDERGROUND SANITARY SEWER AND VENT PIPING: BELL AND SPIGOT COST IRON WITH LEAD AND OAKUM OR NEOPRENE COMPRESSION JOINTS OR HUBLESS CAST IRON WITH TYPE MG CAST IRON COUPLINGS. STAINLESS STEEL BONDS ARE ACCEPTABLE IF COATED WITH BITUMASTIC, ABOVE GROUND SANITARY SEWER AND VENT PIPING: BELL AND SPIGOT CAST IRON WITH LEAD AND OAKUM OR NEOPRENE COMPRESSION JOINTS: OR HUBLESS CAST IRON PIPE AND JOINTING SYSTEM EXCEPT THAT TYPE MG CAST COUPLINGS SHALL BE USED FOE STOCKS MANE THAN 25 FT. HIGH. VENT PIPING MAY ALSO BE SCHEDULE 40 GALVANIZED STEEL WITH CAST IRON SCREWED DRAINAGE FITTINGS. VENT PIPING PASSING THROUGH ROOF: CAST IRON WITH NOT LESS THAN 12" PROJECTION ABOVE ROOF WITH APPROVED FROST JACKETS. WATER PIPING — TYPE L HARD COPPER WITH WROUGHT COPPER FITTINGS AND SHUT —OFF VALVE AT EACH FIXTURE. PIPING OF DISSIMILAR METALS MUST BE DIELECTRIC ALLY ISOLATED. CONDENSATE DRAIN PIPING: SAME AS WATER PIPING. PIPE HANGERS: CONFORM TO ANSI /MSS SP58. CONSTRUCT HANGERS OF CORROSION RESISTANT GALVANIZED STEEL (MICHIGAN #100), EXCEPT PROVIDE COPPER PLATED HANGERS SUPPORTING COPPER PIPING (MICHIGAN #100). SPACE HANGERS AS REQUIRED BY CODE, WITH A MINIMUM OF ONE HANGER PER PIPE JOIST. SUPPORT HANGER FROM TOP OF STRUCTURAL MEMBER. DO NOT SUPPORT FROM ROOF DECK OR OTHER EQUIPMENT. VERTICAL PIPING SHALL BE SUPPORTED WITH STANDOUT HANGERS AT EACH JOINT AND RISER CLAMPS AT FLOOR AND ROOF. SMALL PIPING (3/4" OR LESS) IN WALLS MAY BE SUPPORTED FROM METAL WASTE OR VENT PIPING USING WEJ —IT "ADJUSTABLE SPACER SYSTEM" COMPONENTS. C. TESTING TEST ALL PLUMBING PIPES AS REQUIRED BY STATE, CITY OR LOCAL CODES AND ORDINANCES. TESTS SHALL BE MADE IN THE PRESENCE OF THE PROPER INSPECTION AUTHORITIES, AUTHORIZED REPRESENTATIVE OF TENANTS ARCHITECT AND /OR THE LANDLORD'S ARCHITECT. FURNISH ALL NECESSARY TEST CERTIFICATES TO THE ARCHITECT. D. DISINFECTING WATER PIPES DISINFECT THE ENTIRE WATER SUPPLY SYSTEM, FILLING WITH A SOLUTION OF 50 PPM OF AVAILABLE CHLORINE AND ALLOW TO STAND SIX HOURS BEFORE FLUSHING AND RETURNING TO SERVICE. E. PIPING INSULATION: EDIT FOR THICKNESS REQUIRED. INSULATE DOMESTIC HOT WATER, COLD WATER AND CONDENSATE PIPING WITH 1/2" FIBERGLASS, WITH ALL PURPOSE JACKET: SEAL ALL JOINTS. INSULATE FITTINGS WITH MITERED SEGMENTS AND VAPOR SEALS, INSULATE ALL EXPOSED WASTE AND WATER PIPING ON HANDICAP FIXTURES USING TRUBRO KIT NO. 102W WITH ACCESSORY NO. 105, OR APPROVED EQUAL. F. CUTTING AND PATCHING THIS CONTRACTOR SHALL DO ALL CUTTING AND PATCHING REQUIRED TO INSTALL ANY PORTION OF THIS WORK. PATCH WITH NEW MATERIALS OF THE SAME TYPE THAT WAS REMOVED. REFINISH PATCHED SURFACE TO MATCH EXISTING ADJACENT SURFACES. ALL ROOF PENETRATION BY LANDLORD'S ROOF CONTRACTOR AT FIFE CONTRACTOR'S EXPENSE. G. SANITARY SEWAGE CONNECT NEW WASTE PIPING TO EXISTING SANITARY WASTE AT THE APPROXIMATE LOCATION SHOWN. VERIFY EXACT LOCATION AND INVERT ELEVATION BEFORE COMMENCING WORK. H. COLD WATER SERVICE FURNISH AND INSTALL NEW COLD WATER PIPING FROM EXISTING PIPING TO, AND INCLUDING CONNECTION TO, NEW PLUMBING FIXTURES AND HOT WATER HEATER AS SHOWN ON PLANS. I. DOMESTIC HOT WATER FURNISH AND INSTALL ONE (I) A.O. SMITH ELSF -10 OR EQUAL GLASS LINED ELECTRIC WATER HEATER HAVING ONE 3000 WATT ELEMENT COMPLETE WITH SAFETY CONTROLS, AN ASME LABELED TEMPERATURE AND PRESSURE RELIEF VALVE PIPED AS INDICATED ON PLANS AND TWO (2) SHUT —OFF VALVES. VERIFY VOLTAGE WITH ELECTRICAL CONTRACTOR BEFORE ORDERING. OPERATING WEIGHT 80 LBS. FURNISH AND INSTALL ONE (1) AMITROL, THERMAL EXPANSION TACK. 2 GALLON CAPACITY MODEL: THERM —X— TROL —ST -5. J. GAS PIPING FURNISH AND METAL A COMPLETE GAS PIPING SYSTEM AS SHOWN ON PLANS. GAS LINES SHALL BE BLACK STEEL, SCHEDULE 40. ASTM A -120, WITH MALLEABLE THREADED FITTINGS FOR 2" AND SMALLER, AND WITH STANDARD BUTT — WELDED JOINTS FOR 2-1/2" AND LARGER. FURNISH AND INSTALL A GAS COCK, DIRT LEG, AND UNION CONNECTION TO EACH PIECE OF EQUIPMENT. PAINT ALL PIPING EXPOSED ON ROOFTOP WITH RUST — INHIBITING PAINT. PITCH PIPING AT A UNIFORM GRADE OF 1/4" IN 15 FEET UPWARD IN DIRECTION OF FLOW. SUPPORT PIPING EVERY 5 FEET MIN. SUPPORT AS REQUIRED BY LANDLORD CRITERIA OR BY STANDARD INDUSTRY PRACTICE, IF LANDLORD HAS NO REQUIREMENTS. TESTING AND PURGING OF GAS PIPING SHALL BE DONE PER THE REQUIREMENTS OF THE LOCAL GAS COMPANY, LOCAL CODES, AND APPLICABLE NPFA 54 CODES. CONTACT AND COORDINATE GAS SERVICE, METER AND REGULATOR REQUIREMENTS WITH THE LOCAL GAS UTILITY COMPANY AND THE MALL'S OPERATIONS MANAGER. INCLUDE INSTALLATION COST OF GAS METER AND REGULATOR IN BID IF NOT PROVIDED BY UTILITY COMPANY. K. MISCELLANEOUS PWM8ING ACCESSORIES BACKFLOW PREVENTER: FURNISH AND INSTALL WATTS SERIES 7, OR APPROVED EQUAL BACKFLOW PREVENTER WHERE SHOWN ON DRAWING. 15030 FIRE SPRINKLERS: A. SYSTEMS THE FIRE SPRINKLER SYSTEM AND HEAD LOCATIONS SHALL BE PER TENANTS FIXTURES, PARTITIONS, SOFFITS, DROPS, CEILING HEIGHTS, ETC. SPRINKLER SYSTEM TO INCLUDE DROPS, HEADS AND FACILITIES FOR PROPER DRAINAGE. DESIGN WET SPRINKLER SYSTEM FOR ORDINARY HAZARD GROUP 2 PER LATEST EDITION OF NFPA 13. THE SPRINKLER SYSTEM SHALL BE DESIGNED AND INSTALLED BY A LICENSED FIRE PROTECTION CONTRACTOR IN STRICT ACCORDANCE WITH THE REQUIREMENTS OF THE LANDLORD, LANDLORD'S FIRE INSURANCE UNDERWRITER, AND ALL GOVERNMENTAL AGENCIES AND AUTHORITIES HAVING JURISDICTION OVER THE PREMISES. COMPREHENSIVE SHOP DRAWINGS AND CALCULATIONS SHALL BE SUBMITTED BY THE CONTRACTOR FOR THE APPROVAL BY THE OWNER LANDLORD. LANDLORDS FIRE INSURANCE UNDERWRITER, AND THE FIRE RATING INSPECTION BUREAU (FACTORY MUTUAL). SPRINKLER SHOP DRAWINGS SHALL BE SUBMITTED TO THE LOCAL FIRE MARSHALL'S OFFICE AND RECEIVE THEIR APPROVAL BEFORE ANY INSTALLATION CAN BEGIN. APPROVED DRAWINGS MUST BE AT THE JOB SITE DURING CONSTRUCTION. AFTER RECEIPT OF APPROVAL AND BEFORE PROCEEDING WITH ANY INSTALLATION WORK. TENANT SHALL FORWARD TWO (2) SPRINKLER SHOP DRAWING BLUELINE PRINTS BEARING THE FIRE INSURANCE UNDERWRITERS STAMP OF APPROVAL TO THE LANDLORD FOR HIS RECORDS. SPRINKLER HEADS LOCATED AT THE STOREFRONT, IN SHOWCASE WINDOWS AND IN HARD SURFACE CEILINGS MUST BE CONCEALED TYPE. HEADS LOCATED IN ACOUSTIC CEILING MAY BE SEMI — RECESSED TYPE. SURFACE MOUNTED HEADS ARE PERMITTED IN NON — CUSTOMER AREAS ONLY. UNLESS OTHERWISE NOTED, ALL FIRE PROTECTION SPRINKLER HEADS SHALL BE QUICK RESPONSE (QR) TYPE. SPRINKLER HEAD TYPES SHALL BE AS FOLLOWS: ALL SPRINKLER HEADS IN AREAS WITH FINISHED CEILINGS TO BE RELIABLE MODEL G4QR CONCEALED PENDANT WITH STANDARD WHITE FINISH. ALL SPRINKLER HEADS IN AREAS WITH UNFINISHED CEILING TO BE RELIABLE MODEL FIFR UPRIGHT WITH CHROME FINISH. SPRINKLER IN TOILET ROOMS, OFFICE AND NON— CUSTOMER AREAS WITH FINISHED CEILING TO BE RELIABLE MODEL F1FR SEMI— RECESSED PENDANT TYPE. VERIFY TYPES AND FINISHES WITH ARCHITECT. SHUT DOWN OF LANDLORD'S SPRINKLER MAIN SHALL BE ONLY DONE ON A SCHEDULE ESTABLISHED BY LANDLORD. ANY DAMAGE CAUSED BY THIS CONTRACTOR TO LANDLORD'S SPRINKLER SYSTEM WILL BE REPAIRED BY LANDLORDS CONTRACTOR AT THIS CONTRACTORS EXPENSE. THE SPRINKLER SYSTEM SHALL BE TESTED AT WATER PRESSURE OF 200 PSIG FOR A PERIOD OF TWO (2) HOURS IN THE PRESENCE OF LANDLORDS REPRESENTATIVE OR AS REQUIRED BY LANDLORD. SPRINKLER PIPING SHALL BE SCHEDULE 10 AND SCHEDULE 40 BLOCK STEEL. HANGERS SHALL BE AS REQUIRED BY NFPA 13. UPON COMPLETION OF THE SYSTEM AND ON POSSESSION OF PREMISES, SUBMIT A WRITTEN CERTIFICATE TO LANDLORD FROM THE UNDERWRITER STATING THAT THE SYSTEM WAS INSPECTED AND APPROVED. 15040 HEATING, VENTING AND AIR CONDITIONING: (THE WORD CONTRACTOR IN THIS SECTION SHALL REFER TO TENANT MECHANICAL CONTRACTOR). A. SCOPE UNLESS STATED OTHERWISE, THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS AND EQUIPMENT FOR THE INSULATION OF A COMPLETE AND TENANT ACCEPTABLE OPERATING HEATING AND AIR CONDITIONING SYSTEM HEREIN DESCRIBED, AND AS SHOWN ON PLANS. THE SPACE IN GENERAL SHALL BE HEATED AND COOLED BY MEANS OF A PACKAGED ROOFTOP AIR CONDITIONING UNIT(S) WITH GAS HEAT AND UTILIZING A DX COIL AND PACKAGED AIR COOLED CONDENSING COMPRESSING UNIT(S) FOR COOLING. B. ROOFTOP AIR CONDITIONING UNIT(S) PROVIDE CARRIER, TRANE, OR APPROVED EQUAL ROOFTOP AIR CONDITIONING UNIT(S) AS SCHEDULED ON THE DRAWINGS. UNIT(S) SHALL BE COMPLETE WITH BELT — DRIVEN FAN, ADJUSTABLE DRIVE, INTERNALLY INSULATED HOUSING, DIRECT EXPANSION COOLING COIL, GAS HEAT, COMPRESSOR, AIR COATED CONDENSER, DRIP PAN, FILTER SECTION WITH THROWAWAY PLEATED FILTERS, INTERNAL VIBRATION ISOLATORS, AND 14" HIGH ROOF CURB. FURNISH UNIT(S) WITH ADDITIONAL ACCESSORIES AS SCHEDULED ON THE DRAWINGS. VERIFY OPERATING VOLTAGE WITH ELECTRICAL CONTRACTOR BEFORE ORDERING. C. CONTROLS PROVIDE ALL CONTROLS, WIRING, SENSORS, RELAYS. ETC. FOR A COMPLETE OPERATING SYSTEM THAT IS COMPATIBLE WITH INSTALLED EQUIPMENT ARID ALL LANDLORD REQUIREMENTS, INCLUDING EMERGENCY SHUTDOWN OF HVAC EQUIPMENT, UNLESS NOTED OTHERWISE. PROVIDE MULTI —STAGE HEAT /COOLED PROGRAMMABLE THERMOSTAT COMPATIBLE WITH INSTALLED EQUIPMENT AND LANDLORDS SYSTEM. THERMOSTAT SHALL BE HONEYWELL T -7300 OR EQUIVALENT PRODUCT FURNISHED BY THE MANUFACTURER OF THE INSTALLED EQUIPMENT. THERMOSTAT SHALL BE MOUNTED 5' -6" ABOVE FINISHED FLOOR, UNLESS NOTED OTHERWISE ON THE DRAWINGS. D. SEQUENCE OF OPERATION OCCUPIED HOURS: SUPPLY FAN SHALL OPERATE CONTINUOUSLY AND THE OUTSIDE AIR DAMPER SHALL BE OPEN TO THE MINIMUM POSITION. DX COIL OR GAS SHALL CYCLE TO MAINTAIN SPACE TEMPERATURE SETPOINT. UNOCCUPIED HOURS: OUTSIDE AIR DAMPER SHALL BE CLOSED. SUPPLY FAN AND CONDENSING UNIT OR ELECTRIC HEATING SHALL CYCLE TO MAINTAIN SPACE TEMPERATURE SETPOINT. ECONOMIZER MODE: DIFFERENTIAL ENTHALPY CONTROLLED ECONOMIZER SHALL ACTIVATE WHENEVER THE OUTSIDE AIR ENTHALPY IS LOWER THAN THE ENTHALPY CONTROL SETTING. ECONOMIZE, DAMPERS SHALL MODULATE TO FULL OPEN POSITION, AS REQUIRED, TO MAINTAIN DISCHARGE AIR TEMPERATURE BETWEEN 52 AND 58 DEGREES FAHRENHEIT. MECHANICAL COOLING /HEATING SHALL BE LOCKED OUT OF ECONOMIZER MODE. WHEN THE SPACE TEMPERATURE SETPOINT 15 SATISFIED, THE DAMPER SHALL RETURN TO THE MINIMUM OUTSIDE AIR POSITION DURING OCCUPIED MODE AND CLOSE COMPLETELY DURING UNOCCUPIED MODE. SMOKE ALARM MODE: UPON A SIGNAL FROM THE DUCT SMOKE DETECTORS OR ZONE SMOKE EXHAUST /FIRE ALARM SYSTEM, UNIT(S) SHALL SHUT DOWN, AND THE OUTSIDE AIR DAMPER SHALL CLOSE. E. CUTTING AND PATCHING THIS CONTRACTOR SHALL DO ALL CUTTING AND PATCHING REQUIRED TO INSTALL ANY PORTION OF THIS WORK. PATCH NEW MATERIALS OF THE SAME TYPE THAT WAS REMOVED. REFINISH PATCHED SURFACE TO MATCH EXISTING ADJACENT SURFACES. ALL ROOF PENETRATIONS BY LANDLORD ROOF CONTRACTOR AT THIS CONTRACTOR'S EXPENSE. F. DUCTWORK CONSTRUCT ALL LOW VELOCITY DUCTWORK OF APPROPRIATE GAUGE SHEET METAL FOR INDICATED SIZES IN ACCORDANCE WITH SMACNA STANDARDS. ROUTE DUCTWORK SUBSTANTIALLY AS SHOWN ON THE CONTRACT DOCUMENTS. ALL BENDS AND CURVES SHALL BE LONG RADIUS. SEAL ALL DUCTWORK IN ACCORDANCE WITH SMACNA STANDARDS: ABOVE 2" W.G. STATIC PRESSURE — SEAL CLASS "A" BETWEEN 1" AND 2" W.G. — SEAL CLASS "B" LESS THAN 1" W.G. — SEAL CLASS "C" DUCT SIZES SHOWN ON DRAWINGS OR INSIDE DIMENSIONS. INSTALL RIGID ALL METAL DUCT SUPPORT SYSTEMS AS INDICATED IN SMACNA STANDARD. SUPPORT HORIZONTAL DUCTS WITHIN 2 FEET OF EACH ELBOW AND WITHIN 4 FEET OF EACH BRANCH INTERSECTION USING STRAP HANGERS ON EACH SIDE OF FITTING. SUPPORT VERTICAL DUCTS AT A MAXIMUM INTERVAL OF 16 FEET AND AT EACH FLOOR. NO WOOD SHALL BE USED TO SUPPORT OR BRACE DUCTS. PROVIDE SWAY AND SEISMIC BRACING AS REQUIRED BY STATE AND LOCAL CODES OR BY LANDLORD. FLEXIBLE DUCTWORK SHALL BE WIREMOLD WCK OR WK. THERMAFLEX M —KE. FLEXMASTER 3M OR NORFLEX NT -25M. MAXIMUM FLEXIBLE DUCT LENGTHS SHALL BE 5 FT. FLEXIBLE DUCTWORK SHALL BE EXTERNALLY INSULATED WITH UL LISTED 1" FLEXIBLE FIBERGLASS AND NON— COMBUSTIBLE VAPOR BARRIER . INSTALL ADJUSTABLE QUADRANT DAMPERS IN ALL BRANCH DUCTS, AND AS REQUIRED TO BALANCE THE AIR SYSTEM. G. BALANCING AIR SYSTEMS TESTING, ADJUSTING AND BALANCING OF ALL WORK SHALL BE MADE BY AN INDEPENDENT CONTRACTOR WHO A 15 CURRENTLY LICENSED ASSOCIATED AIR BALANCING COUNCIL (AACD) OR NATIONAL ENVIRONMENTAL BALANCING BUREAU (NEBB) BALANCING CONTRACTOR. THE MECHANICAL CONTRACTOR CAN NOT BE USED TO BALANCE THE SYSTEM. ALL BALANCING WORK MUST BE COMPLETE AND DONE IN ACCORDANCE WITH THE MOST RECENT STANDARDS OF THEIR SOCIETY. PAYMENT OF ALL COSTS FOR TESTING AND BALANCING SHALL BE BY THE GENERAL CONTRACTOR. THE HVAC CONTRACTOR SHALL BE PRESENT FOR THE AIR BALANCE TO VERIFY ACCESSIBILITY TO ALL DEVICES, VERIFY ALL OPERATING SEQUENCES. THE MECHANICAL CONTRACTOR SHALL REMOVE AIR FILTER USED DURING CONSTRUCTION AND INSTALL NEW FILTERS IN ALL UNITS JUST PRIOR TO THE AIR BALANCE _ CODE COMPLIANCE k WORK BEING DONE. THE COMPLETE AIR BALANCE SHALL TAKE PLACE WITH OUTSIDE AIR DAMPERS IN i ED FOR MINIMUM POSITION, EXCEPT AS NOTED OTHERWISE. HVAC CONTRACTOR SHALL ALSO INSTALL A NEW SE OF FILTERS AT THE TIME OF PROJECT TURNOVER. ALL CONTROL SEQUENCES SHALL BE TESTED AND CORRECTED /ADJUSTED AS REQUIRED FOR CORRECT OPERATION AS SPECIFIED (INTERLOCKED EQUIPMENT SMOKE DETECTORS, SMOKE EVACUATION, ECONOMIZER. ETC.) AND OPERATING STATUS RECORDED IN THE REPORT. G.C. TO PROVIDE A COPY OF THE FIND BALANCING REPORT TO LANDLORD, TENANT, CODE OFFICIALS (IF REQUIRED) AND 3 COPIES TO THE ENGINEER. NO OTHER BALANCE REPORTS WILL BE REVIEWED OR ACCEPTED. H. START UP OF SYSTEMS. GUARANTEE AND INSTRUCTIONS THIS CONTRACTOR SHALL GUARANTEE AND MAINTAIN THE STABILITY OF ALL WORK AND MATERIALS FOR A PERIOD OF ONE (I) YEAR AFTER THE FINAL PAYMENT FOR COMPLETION OF THE WORK AS EVIDENCED BY FINAL APPROVAL OF TENANT'S ARCHITECT. DEFECTS OF ANY KIND DUE TO FAULTY WORK OR MATERIALS APPEARING DURING THE ABOVE— MENTIONED PERIOD MUST BE IMMEDIATELY CORRECTED BY THIS CONTRACTOR AT HIS OWN EXPENSE TO THE ENTIRE SATISFACTION OF TENANT'S ARCHITECT AND ENGINEERS. SUCH RECONSTRUCTION AND REPAIRS SHALL INCLUDE ALL DAMAGE TO THE FINISH OR FURNISHINGS OF THE BUILDING RESULTING FROM THE ORIGINAL DETECTOR REPAIRS THERETO. TENANTS DESIGNATED OPERATING PERSONNEL SHALL BE FULLY INSTRUCTED BY THIS CONTRACTOR IN THE OPERATION OF EACH MECHANICAL SYSTEM AT THE TIME IT IS BEING PUT IN SERVICE. ASSEMBLE IN PORTFOLIO FORM AND DELIVER TO TENANT BEFORE FINAL PAYMENT 15 MADE FOUR (4) COMBINED SETS OF SHOP DRAWINGS, MANUFACTURERS BULLETINS OR OTHER DATA AS REQUIRED COVERING THE CARE, MAINTENANCE, AND OPERA OF EACH PIECE OF EQUIPMENT FURNISHED. I. DIFFUSERS. GRILLES AND REGISTERS FURNISH AND INSTALL: TITUS, OR APPROVED EQUAL CEILING DIFFUSERS AS SCHEDULED. IF CONTRACTOR WISHES TO SUBMIT DIFFERENT GRILLES, REGISTERS, OR DIFFUSERS, CONTRACTOR WILL SUBMIT SHOP DRAWINGS TO ENGINEER PRIOR TO PURCHASING ANY MATERIAL. L. EXHAUST SYSTEM FURNISH AND INSTALL COOK. PENN, GREENHECK OR EQUAL, CEILING EXHAUST FAN WITH BACKDRAFT DAMPERS AND DUCTWORK COMPLETE AS SHOWN ON DRAWINGS. M. INSULATION 1. ALL CONCEALED SUPPLY DUCTWORK SHALL BE EXTERNALLY INSULATED. a. MATERIAL: OWENS— CORNING OR APPROVED EQUAL 1/2" REINFORCED FOIL FACED FIBERGLASS (VAPOR SEALED) INSULATION. INSTALL IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. 2. EXPOSED SUPPLY DUCTWORK SHALL BE ACOUSTICALLY LINED 10' -0" MINIMUM FROM ANY FAN OR SHOWN ON THE PLANS. a. ACOUSTICAL INTERNAL INSULATION SHALL BE I" OWENS — CORNING FIBERGLASS COATED DUCT LINER BOARD OR APPROVED EQUAL. DUCT SIZES SHOWN ON PLANS ARE INSIDE CLEAR DIMENSIONS. APPLY INSULATION WITH MANUFACTURER'S APPROVED ADHESIVES, MASTICS AND MECHANICAL FASTENERS. 3. ALL RETURN EXPOSED OR CONCEALED SHALL BE ACOUSTICALLY LINED 10' -0" MINIMUM FROM ANY FAN OR AS SHOWN ON THE PLANS. a. ACOUSTICAL INTERNAL INSULATION SHALL BE 1" OWENS— CORNING FIBERGLASS COATED DUCT LINER BOARD OR APPROVED EQUAL. DUCT SIZES SHOWN ON PLANS ARE INSIDE CLEAR DIMENSIONS. APPLY INSULATION WITH MANUFACTURER'S APPROVED ADHESIVES, MASTICS AND MECHANICAL FASTENERS. N. SMOKE DETECTORS CONTRACTOR TO FURNISH AND INSTALL PYROTRONICS OR APPROVED EQUAL, IONIZATION TYPE DUCT SMOKE DETECTOR IN RETURN AIR DUCT TO DE— ENERGIZE SUPPLY AIR UNIT UPON ACTIVATION. ELECTRICAL CONTRACTOR TO PROVIDE POWER TO SMOKE DETECTOR. APPROVED SAY - 5 2008 RECEIVED CITY OF TUKWILA APR 2 4 2008 PERMIT CENTER 1057 Southcenter Mall Tukwila, WA 98188 smith co. 1725 westlake ave. n. suite 210 seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith @smithco.org http://www.smithco.org/ Consultant Consultant Registration Issues and Revisions OW of Tukwila I No. BUILD ® . . s 1 03.31.08 Date Issues PER Project Number 02008018,00 vllT 6294 Architect Registration Project Name WESTFIELD SOUTHCENTER MALL By Check KLS Description MECHANICAL SPECIFICATI ❑NS Computer File CW05- 2008— M2,DWG Scale AS NOTED Template 4.3 (120101) All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. IIc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. 11c. M -3