Loading...
HomeMy WebLinkAboutPermit M08-117 - WESTFIELD SOUTHCENTER MALL - BJ'S RESTAURANT AND BREWERYBJ'S RESTAURANT AND BREWERY 1159 SOUTHCENTER MALL M08 -117 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: 6364200010 1159 SOUTHCENTER MALL TUKW GREG EDWARDS Address: PO BOX 94243 , SEATTLE WA Contractor: Name: ATEKA HEATING & AIR LLC • Address: 906 PIKE ST NW , AUBURN WA Contractor License No: ATEKAHA943U1 DESCRIPTION OF WORK: INSTALL REFRIGERATION LINES FROM EQUIPMENT TO CONDENSORS ON ROOFTOP Value of Mechanical: $18,500.00 Type of Fire Protection: doc: I MC =10/06 WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD CA BJ'S RESTAURANT 1159 SOUTHCENTER MALL , TUKVVILA WA Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial CitAf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT Fees Collected: $383.75 International Mechanical Code Edition: 2006 EOUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 0 0 0 0 0 0 0 0 * *continued on next page ** M08 -117 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 510 -3458 Phone: 253 - 333 -7294 Expiration Date: 03/21/2010 M08 -117 05/09/2008 11/05/2008 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 Printed: 05 -09 -2008 Permit Center Authorized Signature: I hereby certify that I have read and a ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance ofw9rk. I am authorized to sign and obtain this mechanical permit. Signature: Print Name: doc: IMC -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us r, 7 e pkipe - Permit Number: M08 -117 Issue Date: 05/09/2008 Permit Expires On: 11/05/2008 ot469 Date bJ di Date: Or' 7 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M08 -117 Printed: 05-09 -2008 Parcel No.: 6364200010 Address: 1159 SOUTHCENTER MALL TUKW Suite No: Tenant: BJ'S RESTAURANT 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: M08 -117 Status: ISSUED Applied Date: 04/25/2008 Issue Date: 05/09/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. * *continued on next page ** doc: Cond -10/06 M08 -117 Printed: 05-09 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the perf . ance of work. Signature: Print Name: 6re5 4J—S doc: Cond -10/06 M08 -117 Date: (r ordinances governing or local laws regulating Printed: 05-09 -2008 Site Address: Tenant Name: Contact Person: E -Mail Address: Contact Person: E -Mail Address: CITY OF TUKWIe Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://wwwatukwila.wa.us MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: Qk W\CCifl-> JM (k Res-4,w r iAcv\k- Property Owners Name: (7 S3 Scat ) \ t -c<,lf\tohkA Mailing Address: �t"Sac'\ ( sr - 9 ckk Ce - Cit Name: G1 -Gt L K,D Mailing Address: -P e 1- 01C City E -Mail Address: ATE �A +✓ 1 )J&1 i wt 6'1 A , )i ,)c Fax Number: Company Name: 1 ik \ & ' rA GJ r- v s W t 2 Mailing Address: , 0 L Contact Person: G R E S E -Mail Address: TEK,/t t (Li -41 ;r (/ Contractor Registration Number: -A1 1-t A bj 1 3 cA Q:\Applications\Forms- Applications On Line3-2006 - Mechanical Permit Application.doc Revised'. 4 -2006 bh Mechanical hermit No. AT 09 nn Project No. poi"- (27 For office use only) Suite Number: Day Telephone: �e__ New Tenant: Floor: 1 .... Yes 0 ..No LI) t 1FASP, State Zip CONTACT PERSON - who do we contact when your permit is ready to l ) A 9 Oa i � State Zip 17 a MECHANICAL CONTRACTOR INFORMATION - 1 a q City State Zip Day Telephone: Fax Number: S3 S 3 �j' (.?S Expiration Date: 37,47,20/0 ARCHITECT OF RECORD; - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: City Day Telephone: Fax Number: State Zip ENGINEER OF RECORD - = All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Day Telephone: Fax Number: State Zip Page 1 of 2 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended /Wall/Floor Mounted Heater Ventilation System Wood /Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Heat /Refrig /Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator — Comm /Ind Other Mechanical Equipment Valuation of Project (contractor's bid price): $ ��j COO ' I Scope of Work (please provide detailed information): 1- - C ` c.)A ea7 Lv\ S \A n AsLCe\ S rCJt'` C�t �^Q y Cam' (v\tii eV\ 6G f t l c� ��� Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New Replacement .... ❑ Fuel Type: Electric ❑ Gas ....0 Other: Indicate type of mechanical work being installed and the quantity below: PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE R AUTHO IZE AGENT: Signature: J Print Name: 6t RF OL J,ki) S Mailing Address: - P,C) Date Application Accepted: rt Q\Applications\Fonns- Applications On Line \3 -2006 - Mechanical Permit Application.doc Revised: 4 -2006 bh Date: ' 1 - - - — c Day Telephone: , - SLU -- - g KS B S 1P\ 9k Y City State Zip Staff Initials: \ Page 2 of 2 Parcel No.: 6364200010 Permit Number: M08 -117 Address: 1159 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 04/25/2008 Applicant: BJ'S RESTAURANT Issue Date: Receipt No.: R08 -01532 Initials: User ID: Payee: TRANSACTION LIST: Type Method Descriptio Amount ACCOUNT ITEM LIST: Description (inn! Reraint -OA JEM 1165 ATEKA HEATING & AIR, LLC Payment Check 2498 323.75 MECHANICAL - NONRES PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http:/lwww.ci.tukwila.wa.us RECEIPT Account Code Current Pmts 000.322.102.00.0 307.00 000/345.830 16.75 Total: $323.75 Payment Amount: $323.75 Payment Date: 05/09/2008 08:46 AM Balance: $0.00 2206 05/09 9711 TOTAL 323.75 Printe.1 n5- f)9 -2noR Receipt No.: R08 -01335 Initials: JEM User ID: 1165 Payee: ATEKA HEATING AND AIR ACCOUNT ITEM LIST: Description doc: Receipt-06 PLAN CHECK - NONRES City of Tukwila Department of Community De 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Payment Cash 60.00 TRANSACTION LIST: Type Method Descriptio Amount RECEIPT Parcel No.: 6364200010 Permit Number: M08 -117 Address: 1159 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 04/25/2008 Applicant: BJ'S RESTAURANT Issue Date: Account Code Current Pmts 000/345.830 60.00 Total: $60.00 Payment Amount: $60.00 Payment Date: 04/25/2008 09:50 AM Balance: $323.75 1646 04/25 9711 TOTAL 60.00 Printed: 04 -25 -2008 Project: S 41!. Type of Inspection: , FMe& Address: / J5..9 /nal/ Date Called: Special Instructions: Date Wanted: .77/r/ , a p� -.r. Requester: Phone No 7 :/n 3Y,SS' Fr- 1 fib INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Q>� Inspector: Date: El $60.00 REINS ECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 S_9uthcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: IDate: Project„ a � S Type of ^t I Address: Date Called: Special Instructions: d Date Wanted �� a.m Requefter: Phone No -.2 _ O _ INSPECTION RECORD Retain a copy with permit rnt r 17 INSPECTION NO. ' PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. ® Corrections required prior to approval. COMMENTS: 1 , i�,k,/ r� '��' "4441 1, 'cs . S eat 17 $60.0 tEINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Project: i Type of Inspection: ze.4 Address: 1/s, Mai/ Date Called: Special Instructions: Date Wanted: / 6 a.m. p.m. Requester: Phone No: INSPECTION NO. INSPECTION RECORD Retain a copy with permit p1�1D� - /, PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1d-- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 COMMENTS: Ch CI ;OM3 GOP1419 le le Inspector: L Date: 6 4A 8) Approved per applicable codes. Corrections required prior to approval. $ 58.0 EINSP ECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: 'Date: .....■ COMMENTS: [[ eheL/, 4 (t / j c PtoTi am 14 a S - #0 Roo psi. fn herrittagi 0 Date C per b /4 ya , A k- I ,rid 7 -0.2w - 8. Date W nted /�! 6 � � - `� p.m. Requester: P � iJ zir 3/0 —7b43.79 Projec 1 /f - -4/ Y of I�spec 4,d11,-, alid�711 Address: _5' / // Date C Special Instructions: Date W nted /�! 6 � � - `� p.m. Requester: P � iJ zir 3/0 —7b43.79 Inspector: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING- DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. Corrections required prior to approval. Date / / , l 2' p $58 ' EINSPECTION FEE REQUIRED. Prior o inspection. fee must be pai : at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: *EMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M08 -117 DATE: 04 -25 -08 PROJECT NAME: BJ'S RESTAURANT SITE ADDRESS: 1159 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Bui : j g D'iJfsi n Public Works Complete Comments: Please Route Documents/routing slip.doc 2 -28 -02 REVIEWER'S INITIALS: Fir revention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete n TUES/THURS ROUTING: 1 Structural Review Required APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: n Planning Division ❑ Permit Coordinator n DUE DATE: 04-29-08 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DATE: n DUE DATE: 05-27-08 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License ATEKAHA943U1 Licensee Name ATEKA HEATING & AIR LLC Licensee Type CONSTRUCTION CONTRACTOR UBI 602592091 Ind. Ins. Account Id Received Date Business Type LIMITED LIABILITY COMPANY Address 1 906 PIKE ST NW Address 2 City AUBURN County KING State WA Zip 98001 Phone 2533337294 Status ACTIVE Specialty 1 AIR HEAT,VENTILATION,EVAPORAT Specialty 2 UNUSED Effective Date 3/21/2006 Expiration Date 3/21/2010 Suspend Date Separation Date Parent Company Previous License ATEKAHA956K5 Next License Associated License Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #3 AMERICAN STATES INS CO 6478746 04/01/2007 Until Cancelled $6,000.00 04/06/2007 Business Owner Information Name Role Effective Date Expiration Date EDWARDS, GREGORY J PARTNER/MEMBER 03/21/2006 Look Up a Contractor, Election or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. • Page 1 of 2 https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= ATEKAHA943U1 05/09/2008 att ABV AFF ACC AP AC ACT ADJ ADJT AGG ALT AL ANC AB ARCH AD ASPH AWN BKR BM ERG BPL BEL BET BEY BLKG BD BS BOT BRKT BRK BLDG BO CAB CABINET CAN CANVAS CPT CARPET a CAST IRON CST CAST STONE CB CATCH BASIN CLG CEILING CM CENTIMETER (5) CT CERAMIC TILE CHAM CHAMFER CIRC CIRCUMFERENCE CLR CLEAR, CLEARANCE CLS CLOSURE COL COLUMN CONC CONCRETE CMU CONCRETE MASONRY UNIT CONN CONNECTION CONST CONSTRUCTION CONT CONTINUE, CONTINUOUS CONTR CONTRACT. CONTRACTOR CJT CONTROL JOINT CORR CORRUGATED CT COUNTER DPR DAMPER DL DEAD LOAD DEM DEMOLISH, DEMOLITION D TL DETAIL DIAG DIAGONAL DIA DIAMETER DIMENSION DOOR DOWN DOWNSPOUT DRAWER DRAWING DRINKING FOUNTAIN DIM DR: DNz DS,. DW4 DWG DF EACH EACH FACE EACH WAY NT EASEMENT C ELECTRIC, (AL) ELECTRICAL PANELBOARD ELEVATION E EQUAL ESTIMATE EXHAUST EXISTING EXPANSION BOLT EXPANSION JOINT EXTERIOR FACE OF CONCRETE: FACE OF FINISH :EOM, FACE OF MASONRY FOS FACE OF STUDS IF'_ FASTEN, FASTENER F%i FIBERGLASS FIN ; FINISH, (ED) FEE_ FINISHED l.FLOOR ELEVATION 5 FIRE EXTINGUISHER FEC FIRE EXTINGUISHER CABINET FRT FIRE -- RETARDANT FIXT FIXTURE FL.GG FLASHING FLY.X-y FLEXIBLE FG FLOAT GLASS FLR FLOOR, (ING) FLOOR DRAIN FLOW UNE F[G FOOTING FND FOUNDATION F FRAME, (D), (ING) FUR FURRED, (ING) GA, GAGE, GAUGE GG GALVANIZED GC GENERAL CONTRACT, (OR) G6 GLASS, GLAZING GRAM GLUED LAMINATE GRAB .BAR GRADING G GRADE, GRT GRATE, (ING) uzGt- GRAVEL GROUT . D GUARD T GUTTER _W GYPSUM WALLBOARD HANDICAP L HANDRAIL HARDWARE R HEADER AC HEATING/VENTILATING/ AIR CONDITIONING HEIGHT ;i 9R HORIZONTAL IIjCAN INCANDESCENT L I1 (ED), (ING) Its ..INSIDE DIAMETER I. INSULATING GLASS )I ;; ANTERIOR INV }: "=INVERT f, .i,J0INT ; I : 1QIST .; CICKPLATE = KITCHEN 1.41�DDER , ,,Ll-AAG BOLT LAMINATE, (ED) -LGL :LAMINATED GLASS ` AV LAVATORY : LLEFT HAND LENGTH `LIGHT LINTEL LIVE LOAD Oc 'LOCATE LOUVER NAT NOM ; r;Jp NIC • NTS MANHOLE MANUFACTURE, (ER) MASONRY MATERIAL MAXIMUM MECHANIC, (AL) MEDIUM MEDIUM DENSITY OVERLAY MEMBER MEMBRANE METAL METER, (5) MIWMETER, (SS MINIMUM MIRROR MISCELLANEOUS MOLDING, MOULDING MOUNT, (ED), (ING) MOVABLE MULLION ATURAL OMINAL 'NOT IN CONTRACT NOT TO SCALE • . ABOVE ABOVE FINISHED FLOo ACCESS ACCESS PANEL ACOUSTICAL ACOUSTICAL TILE ADJACENT ADJUSTABLE AGGREGATE ALTERNATE ALUMINUM ANCHOR, ANCHORAGE ANCHORBOLT ARCHITECT, ARCHITECTURAL AREA DRAIN 'ASPHALT AWNING BACKER BEAM BEARING BEARING PLATE BELOW BETWEEN BEYOND BLOCKING BOARD BOTH SIDES BOTTOM BRACKET BRICK BUILDING BY OWNER ABBREVATIONS OC ON CENTER, (S) OPG OPENING OPH OPPOSITE HAND ORN ORNAMENTAL OD OUTSIDE DIAMETER OA OVERALL OH -OVERHEAD PNT PAINT, ED) PNL PANEL, (ING) PB PANIC BAR PTD PAPER TOWEL DISPENSER PTR PAPER TOWEL RECEPTOR PRPT PARAPET PTN PARTITION PVMT PAVEMENT PERF PERFORATE, (ED) PER PERIMETER PLTG PLANTING PLAS PLASTER PLA PLASTIC PLAM PLASTIC LAMINATE PL PLATE PG PLATE GLASS PWD PLYWOOD PD POUND,(S) PCF POUNDS PER CUBIC FOOT PLF POUNDS PER LINEAR FOOT PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PCC PRECAST CONCRETE PT PRESSURE TREATED PL PROPERTY UNE QT QUARRY TILE RAD RADIUS RFT RAFTER RL RAIL, (ING) REC RECESS. (ED) REF REFER, (ENCE) RFT_ REFLECT, (ED), (IVE), (OR) REG REGISTER REIN REINFORCE, (ED), (ING) REM REMOVE, (ABLE) REQ'D REQUIRED RA RETURN AIR REV REVISE, (5), REVISE, (ED) ROW RIGHT OF WAY RISER RD ROOF DRAIN RFH ROOF HATCH RFG ROOFING RM ROOM RO ROUGH OPENING ROK ROWLOCK RB RUBBER BASE SFGL SAFETY GLASS SCH SCHEDULE SCN SCREEN, (ED) SCUP SCUPPER SNT SEALANT STG SEATING SEC SECTION SVYD SERVICE YARD SHTH SHEATH, (ING) SHT SHEET SH SHELF, SHELVING SHNG SHINGLE, (S) SHU SHUTTER, (S) SIDG SIDING SIM SIMILAR SLO SLOPE SQL SOLDIER SC SOLID CORE SPC SPACE, (R) SPK SPEAKER SPEC SPECIFICATION SQ. SQUARE SST STAINLESS STEEL STD STANDARD ST STEEL STO STORAGE SF STOREFRONT SD STORM DRAIN STR STRUCTURAL ITCG STUCCO SFLR SUBFLOOR SA SUPPLY AIR SYD SIDE YARD SYN SYNTHETIC SYS SYSTEM TEL TELEPHONE T1/ TELEVISION TG TEMPERED GLASS TIG TEMPERED, INSULATED GLASS THK THICK, (NESS) TOR THRESHOLD TBRL TO BE RELOCATED TOBR TO BE REMOVED TPD TOILET PAPER DISPENSER TPTN TOILET PARTITION TSL TOP OF CONCRETE SLAB TC TOP OF CURB TJ TOP OF JOIST TP TOP OF PLATE TST TOP OF STEEL TSF TOP OF SUBFLOOR TW TOP OF WALL TOR TO REMAIN TR TRANSOM T TREAD TYP . TYPICAL UNF UNFINISHED UNO UNLESS NOTFTHERWISE UR URINAL U.31. UTTUTY VNR VENEER VERT VERTICAL VIN ANYL VB , BASE VCT VINYL COMPOSITION TILE VF VINYL FABRIC VT VINYL TILE WSCT WH WC , WHTR WP WST WWF WHS WIN WG WO WD WI SYMBOLS USED AS ABBREVIATIONS O AT SPACING OF B.M. 4. i 1 WAINSCOT WALL HUNG WATER CLOSET WATER HEATER WATERPROOFING WEATHERSTRIP, (ING) WELDED WIRE FABRIC WHEEL STOP WINDOW WIRED GLASS WITHOUT WOOD WROUGHT IRON BENCH MARK CENTER UNE CHANNEL NUMBER PERPENDICULAR PLATE ROUND SQUARE DRAWING TITLE SECTION DETAIL (ENLARGED) ELEVATION CEILING HEIGHT DOOR WINDOW FINISH MATERIAL KEYED NOTES REVISIONS . ELEVATION HEIGHT . . . EQUIPMENT • • WALL TYPE - --WALL TYPE LETTER EXISTING STRUCTURE CENTERLINE . NEW STRUCTURE CENTERLINE WALL LEGEND §;1„.02V6VAgateldgizAcilu .0‘0", 02020:0:05M1,10: : .. OMB. BJ'S RESTAURANTS, INC. 7755 CENTER AVENUE HUNTINGTON BEACH, CA 92647 PHONE 714.500.2400 SYMBOL LEGEND • ARCHITECT CARTER & BURGESS, INC. 1420 WEST MOCKINGBIRD LANE, SUITE 800 DALLAS, TEXAS 75247 -4925 PHONE: 214.920.8100 FAX: 214.688.0618 EMAIL: SCOTT.WINDLE@C -B.COM CONTACT: SCOTT WINDLE STRUCTURAL ENGINEER CARTER & BURGESS, INC. 1420 WEST MOCKINGBIRD LANE, SUITE 800 DALLAS, TEXAS 75247 -4925 PHONE 214.920.8100 FAX: 214.688.0618 EMAIL TRAV.SWEATMANRc -b.com CONTACT: TRAV SWEATMAN P -1 4 T.O. SLAB- REFERENCE POINT 100'- -O� �ELEVA1ION HEIGHT EQUIPMENT NUMBER/LEfIER DESIGNATION FULL HEIGHT PAR - 1110N 6' ABOVE CEILING. FULL HEIGHT PARTITION TO DECK ABOVE. PARTITAL HEIGHT PARTITION, REFER TO ELEVATIONS. ONE HOUR RATED WALL, UL LISTING U465 COOLER/FREEZER WALL, (N.I.C.) DASHED LINES: WALLS /ITEMS TO BE REMOVED. SCREEN UNES: ITEMS TO REMAIN. EXISTING FULL HEIGHT PARTITION TO REMAIN. CODE INFORMATION KITCHEN/ STORAGE AREAS: 2,936 SQ. FT RESTROOM AREAS: 485.2 SQ. FT TOTAL LEASED AREA: 10,66176 SQ. FT. PHONE FAX: EMAIL: CONTACT: PHONE: FAX EMAIL: CONTACT: FLOOR PLAN SCALE: 1 - =1 -0 DRAWING NUMBER SHEET NUMBER SECTION ID. NUMBER SHEET MERE SECTION IS LOCATED DETAIL LD. NUMBER SHEET WHERE SECTION IS LOCATED ELEVATION I.D. NUMBER SHEET WHERE SECTION IS LOCATED CEILING HEIGHT ABOVE FINISHED FLOOR DOOR NUMBER DESIGNATION WINDOW NUMBER DESIGNATION FINISH DESIGNATION TRIM ONLY ,...-COMMENTS, IF APPUCABLE KEYED NOTE DESIGNATION ON APPUCABLE SHEET C::) ,..„... ADDENDUM NUMBER REVISED AREA CLOUDED n A. BUILDING CODE CRITERIA BUILDING CODE: ;2006 -INTERNATIONAL BUILDING CODE W/ WASHINGTON AMENDMENTS ELECTRICAL CODE: • 2005 NATIONAL ELECTRICAL CODE MECHANICAL CODE 2006 INTERNATIONAL MECHANICAL CODE W/ WASHINGTON AMENDMENTS PLUMBING CODE: 2006 UNIFORM PLUMBING CODE W/ WASHINGTON AMENDMENTS FIRE PREVENTION CODE: 2006 INTERNATIONAL FIRE CODE W/ WASHINGTON AMENDMENTS ACCESSIBILITY CODE: OCCUPANCY: A -2 RESTAURANT CONSTRUCTION TYPE IIB SEAT COUNT 253 + PATIO B. BUILDING SQUARE FOOTAGE DINING AREA:: 5,213 5Q. FT. COOLER /FREEZER ENCLOSURES: 519 SQ. FT. LIST OF CONTACTS DESK :NEB BITTON DESIGN GROUP 29229 CANWOOD STREET, SUITE 105 AGOURA HILLS, CA, 91301 818.707,1908 818.707.1936 EDDY€':I TONDESIGN.COM EDDY BITTON PROJECT COORDINATOR CARTER & BURGESS, INC. 1420 WEST MOCKINGBIRD LANE, SUITE 800 DALLAS, TEXAS 75247 -4925 214.920.8100 214.688.0618 JUAN.BROUSSARD©C -B.COM JUAN BROUSSARD MEP. ENGINEER CARTER & BURGESS, INC. 1420 WEST MOCKINGBIRD LANE, SUITE 800 DALLAS, TEXAS 75247 -4925 PHONE 214.920.8100 FAX 214.688.0618 EMAIL KEVIN.SANCIBRIAN@C-B.COM CONTACT: KEVIN SANCIBRIAN • GENERAL PROJECT NOTES 1. APPROVED PLANS SHALL BE KEPT IN A PLAN BOX AND SHALL NOT BE USED BY WORKMEN. ALL CONSTRUCTION SETS SHALL REFLECT SAME INFORMATION. CONTRACTOR SHALL MAINTAIN ONE COMPLETE SET OF PLANS ON THE PREMISES IN GOOD CONDITION AT ALL TIMES. THIS SHALL INCLUDE ALL ADDENDA AND CHANGE ORDERS. 2. THE CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO STARTING ANY WORK AND SHALL BE RESPONSIBLE FOR ALL WORK AND MATERIALS INCLUDING THOSE FURNISHED BY SUBCONTRACTORS AND OWNER. 3. GENERAL CONTRACTOR TO REFER TO THESE DOCUMENTS AS WELL AS SPECIFICATIONS FOR IDENTIFICATION OF ALL OWNER SUPPLIED ITEMS. ALL ITEMS NOT MARKED BY OWNER' OR 'N.I.C.' (NOT IN CONTRACT) ARE TO BE SUPPLIED BY GENERAL CONTRACTOR. UNLESS NOTED OTHERWISE, ALL @TEMS ARE TO . BE INSTALLED BY GENERAL CONTRACTOR. 4. THE TERM *WORK* AS USED IN THESE NOTES SHALL INCLUDE ALL PROVISIONS AS DRAWN OR SPECIFIED IN THESE DOCUMENTS AS WELL AS ALL OTHER PROVISIONS SPECIFICALLY INCLUDED BY THE OWNER IN THE FORM OF DRAWINGS, SPECIFICATIONS, AND WRITTEN INSTRUCTIONS AND APPROVED BY THE ARCHITECT. GENERAL NOTES, RESPONSIBILITY SCHEDULE, FINISH SCHEDULE PLUMBING SEWER AND VENT ISOMETRIC DIAGRAM PLUMBING WATER AND GAS ISOMETRIC DIAGRAMS 02/11/08 REVISION 1 02/21/08 CITY PLMB CMNTS 5. BEFORE SUBMITTING A BID, THE CONTRACTOR SHALL VISIT THE PREMISES AND FAMILIARIZE HIMSELF WITH THE EXISTING CONDITIONS AND THE EXTENT OF WORK REQUIRED TO COMPLETE THE PROJECT. 6. BEFORE CONSTRUCTION BEGINS, THE CONTRACTOR SHALL VISIT THE SITE TO VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS AND SHALL NOTIFY THE ARCHITECT, IN WRMNG OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK AND SHALL BE RESPONSIBLE FOR SAME. 7. IF THE CONTRACT DRAWINGS ARE FOUND TO BE UNCLEAR, AMBIGUOUS OR CONTRADICTORY, THE CONTRACTOR MUST REQUEST CLARIFICATION FROM THE ARCHITECT IN WRRING BEFORE PROCEEDING WITH THAT PART OF THE WORK. 8. THE ARCHITECT SHALL BE AVAILABLE TO VISIT THE SITE WHEN REQUESTED. IF A CONDRTON EXISTS THAT REQUIRES OBSERVATION OR ACTION BY THE ARCHITECT OR ENGINEERS, THE CONTRACTOR SHALL NOTIFY THE OWNER AND ARCHITECT. 9. CONTRACTOR SHALL BE FAMILIAR WITH PROVISIONS OF ALL APPUCABLE CODES AND SHALL INSURE THE COMPLIANCE OF THE WORK WITH ALL LOCAL, STATE AND FEDERAL CODES. IN THE EVENT OF CONFLICT BETWEEN LOCAL, STATE AND NATIONAL CODES, THE MORE STRINGENT SHALL GOVERN. BEFORE COMMENCING WORK NOT SHOWN IN DOCUMENTS, BUT REQUIRED TO ACHIEVE FULL COMPLIANCE WITH CODES, CONTRACTOR SHALL NOTIFY OWNER AND ARCHITECT. 10. THESE DOCUMENTS DO NOT INCLUDE THE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. SAFETY, CARE OF ADJACENT PROPERTIES DURING CONSTRUCTION, COMPLIANCE WITH STATE AND FEDERAL REGULATIONS REGARDING SAFETY AND COMPLIANCE WITH REQUIREMENTS SPECIFIED IN THE OWNER /CONTRACTOR CONTRACT IS, AND SHALL BE, THE CONTRACTOR'S RESPONSIBILITY. 11. CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES AND SAFETY PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK. 12. DO NOT SCALE DRAWINGS. USE WRITTEN DIMENSIONS FOR ALL MEASUREMENTS. ALL DIMENSIONS ARE TO FACE OF STUD UNLESS OTHERWISE NOTED. 13. OWNER SHALL PAY ALL TAXES, SECURE ALL PERMITS AND PAY ALL FEES INCURRED IN THE COMPLETION OF THE PROJECT, INCLUDING BUT NOT LIMITED TO BUILDING PERMITS, WATER, ELECTRIC AND TELEPHONE SERVICE CONNECTION, CERTIFICATE OF OCCUPANCY SURVEY'S AND INSPECTIONS. 14. SCOPE OF WORK. THE CONTRACTOR SHALL INCLUDE AND PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, TRANSPORTATION AND PAY ALL EXPENSES INCURRED IN THE PROPER COMPLETION OF WORK UNLESS SPECIFICALLY NOTED TO BE THE WORK OF OTHERS. CONTRACTOR SHALL PERFORM ALL WORK NECESSARY FOR PRODUCING A COMPLETE, HABITABLE PROJECT, INCLUDING BUT NOT LIMITED TO SITE WORK, ARCHITECTURAL, ELECTRICAL PLUMBING AND HVAC. 15. THE BID PRICES SHALL INCLUDE EVERYTHING NECESSARY OR PROPER FOR PERFORMING AND COMPLETING THE WORK REQUIRED AS INDICATED BY THE PLANS AND SPECIFICATIONS, TO PROVIDE FINISHED WORK. ANYTHING OMITTED THEREFROM WHICH 15 CLEARLY NECESSARY FOR THE COMPLETION OF THE WORK OR ITS APPURTENANCE SHALL BE CONSIDERED A PORTION OF THE WORK ALTHOUGH NOT DIRECTLY SPECIFIED OR SHOWN ON THE DRAWINGS. 1 6. INSURANCE WORKMEN'S COMPENSATION, AS REQUIRED BY LAW, AND PUBLIC LIABILITY SHALL BE CARRIED BY THE CONTRACTOR. 17. GUARANTEE THE CONTRACTOR SHALL UNCONDITIONALLY GUARANTEE ALL MATERIALS, AND WORKMANSHIP FURNISHED OR INSTALLED BY HIM OR HIS SUBCONTRACTORS FOR A PERIOD OF ONE (1) YEAR FROM DATE OF ACCEPTANCE AND SHALL REPLACE ANY DEFECTIVE WORK WITHIN THAT PERIOD WITHOUT EXPENSE TO THE OWNER AND PAY FOR ALL DAMAGES TO OTHER PARTS OF THE BUILDING RESULTING FROM DEFECTIVE WORK OR ITS REPAIR. THE CONTRACTOR SHALL REPLACE DEFECTIVE WORK WITHIN TEN (10) DAYS AFTER R IS BROUGHT TO HIS ATTENTION. 18. PROTECTION: THE CONTRACTOR SHALL BE RESPONSIBLE FOR HIS WORK AND THAT OF HIS SUBCONTRACTORS FOR LOSSES AND DAMAGES TO EQUIPMENT, TOOLS AND MATERIAL USED IN CONJUNCTION WITH THE WORK AND FOR ACTS OF HIS EMPLOYEES. 19. CONTRACTOR IS TO PROVIDE TO THE OWNER A UST OF ALL SUBCONTRACTORS USED, COMPLETE WITH ADDRESSES, PHONE NUMBERS AND COPIES OF ALL WARRANTIES. 20. CONTRACTOR IS TO PROVIDE TO THE OWNER A UST OF ALL SUBCONTRACTORS USED, COMPLETE WITH ADDRESSES, PHONE NUMBERS AND COPIES OF ALL WARRANTIES. 21. THE TERM 'CONTRACTOR" AS USED IN THESE NOTES SHALL REFER TO THE GENERAL CONTRACTOR OR TO THE SUBCONTRACTORS. THE OWNER MAY ELECT TO CONTRACT DIRECTLY WITH A SUBCONTRACTOR FOR ANY PART OF THE WORK. NATIONAL ACCOUNT "NATIONAL ACCOUNT - OWNER HAS ENTERED NATIONAL ACCOUNT AGREEMENTS WITH VENDORS FOR SOME MATERIALS AND PRODUCTS. DEVELOPERS, LANDLORDS AND THEIR ARCHITECTS AND CONTRACTORS SHALL USE THESE VENDORS, WITHOUT SUBSTiTU•I1ON, FOR ALL PRODUCTS IDENTIFIED UNDER THE NATIONAL ACCOUNTS PROGRAM. BB'S •! o B tl FrMici • WESTFIELD SOUTHCENTER 1159 SOUTHCENTER MALL TUKWILA, WASHINGTON 98188 ..9 od&..ii�..✓y,�y:5.le��liT;+is33 4 i�.� .. DRAWING NUMBER: G1.0 SITE PLAN • • SITE LOCATION MAP BpS j •, r � r, . Pc' t •• • 7ai.W +i.•wr+.a..r i.t wi.L.W aa..W46.Y,'ia t1767y . r :76 rV _, 1 TRUE TRUE n ARCHITECTURAL EGRESS/FURNITURE PLAN ENLARGED FLOOR PLAN AND DETAILS EXTERIOR ELEVATIONS EXTERIOR ELEVATIONS /INTERIOR ELEVATIONS INTERIOR ELEVATIONS INTERIOR ELEVATIONS INTERIOR ELEVATIONS WALL SECTIONS WALL SECTIONS/DETAILS • • • • • • • • • WALL SECTIONS /DETAILS DETAILS (EXTERIOR) DETAILS DETAILS DETAILS • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • A1.6 A2.0 A2.1 A2.2 A2.3 A2.4 A3.0 A3.1 A3.2 A4.0 A4.1 A4.2 A4.3 A5.0 SP1,0 SP1.1 SP1.2 FOOD SERVICE: PLUMBING: MECHANICAL M1.0 M2.0 ELECTRICAL: TITLE, DRAWING INDEX, GENERAL NOTES. & .INFORMATION • SCHEDULES AND DETAILS OWNER CMNTS F CO0 , L O %e 5 �� p , Mai_ n :.SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical Iectrical Iumbing Ller Gas Piping City of Tukwila R! 11 " °ANN G DIVISION • • FILE COPY Permit NO. Pia!' review approval is Stabs to errors and ontlssIons- Approval of construction documents does not authorize the violation of an adopted code or ordnanze. Receipt of approved Fie is wedged: By Date: , --7- City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees . .. • • • • • • • • • • • • • • MECHANICAL FLOOR PLAN • • CarteriBurgess CARTER & BURGESS, INC. 1420 WEST MOCKINGBIRD LANE, #800 DALLAS, TEXAS 75247-4925 4934 REGISTERED ARCHITECT .;; SC f WI t. LE � F' SHIN ON T ' 3.11.2008 co CC ; 1- < C) Z Z 0 CC O I CI] 0 co 0 1- W O CO wze co 0 1-- 7755 CENTER AVE STE. 300 HUNTINGTON BEACH, CA. 92647 INLINE CO JOB NUMBER: 024203.014 DATE ISSUED: 01 -25 -08 FOR PERMIT ISSUES: HEALTH DEPT PERMIT CONSTRUCTION SHEET CONTENTS: SHEET NUMBER: G1.0 CITY RECEIVED APR 2 4 2008 PERMIT CENTER Nom- (f1- 11/30/07 01/25/08 03/11/08 REVISIONS: , REVISION 1 ` 3" 2/11/08 /\CITY PLMB CMNTS 2/21 /08 CITY MECH CMNTS 2/22/08 ACITY BUILD CMNTS 2/22/08 /CITY ELEC CMNTS 2/22/08 / \CLARIFICATIONS 2/22/08 OWNER CMNTS 2/22/08 ,, 8 ISSUED FOR CONST. 3/11 /08 TITLE, DRAWING INDEX, LEGENDS, GENERAL NOTES & INFORMATION tSD 1 • tERAL` - N OTES . t . , 1 t� .1 . : ,, rr _ S1.1 ROOF PLAN . • �� 4' 1 ."...::,-,..k.:7 S3.0 . S4.0 FOUND A11QtJ DETAILS :: - y,?'`f"'' ' : r=:f1 ROOF DETAILS ®III att ABV AFF ACC AP AC ACT ADJ ADJT AGG ALT AL ANC AB ARCH AD ASPH AWN BKR BM ERG BPL BEL BET BEY BLKG BD BS BOT BRKT BRK BLDG BO CAB CABINET CAN CANVAS CPT CARPET a CAST IRON CST CAST STONE CB CATCH BASIN CLG CEILING CM CENTIMETER (5) CT CERAMIC TILE CHAM CHAMFER CIRC CIRCUMFERENCE CLR CLEAR, CLEARANCE CLS CLOSURE COL COLUMN CONC CONCRETE CMU CONCRETE MASONRY UNIT CONN CONNECTION CONST CONSTRUCTION CONT CONTINUE, CONTINUOUS CONTR CONTRACT. CONTRACTOR CJT CONTROL JOINT CORR CORRUGATED CT COUNTER DPR DAMPER DL DEAD LOAD DEM DEMOLISH, DEMOLITION D TL DETAIL DIAG DIAGONAL DIA DIAMETER DIMENSION DOOR DOWN DOWNSPOUT DRAWER DRAWING DRINKING FOUNTAIN DIM DR: DNz DS,. DW4 DWG DF EACH EACH FACE EACH WAY NT EASEMENT C ELECTRIC, (AL) ELECTRICAL PANELBOARD ELEVATION E EQUAL ESTIMATE EXHAUST EXISTING EXPANSION BOLT EXPANSION JOINT EXTERIOR FACE OF CONCRETE: FACE OF FINISH :EOM, FACE OF MASONRY FOS FACE OF STUDS IF'_ FASTEN, FASTENER F%i FIBERGLASS FIN ; FINISH, (ED) FEE_ FINISHED l.FLOOR ELEVATION 5 FIRE EXTINGUISHER FEC FIRE EXTINGUISHER CABINET FRT FIRE -- RETARDANT FIXT FIXTURE FL.GG FLASHING FLY.X-y FLEXIBLE FG FLOAT GLASS FLR FLOOR, (ING) FLOOR DRAIN FLOW UNE F[G FOOTING FND FOUNDATION F FRAME, (D), (ING) FUR FURRED, (ING) GA, GAGE, GAUGE GG GALVANIZED GC GENERAL CONTRACT, (OR) G6 GLASS, GLAZING GRAM GLUED LAMINATE GRAB .BAR GRADING G GRADE, GRT GRATE, (ING) uzGt- GRAVEL GROUT . D GUARD T GUTTER _W GYPSUM WALLBOARD HANDICAP L HANDRAIL HARDWARE R HEADER AC HEATING/VENTILATING/ AIR CONDITIONING HEIGHT ;i 9R HORIZONTAL IIjCAN INCANDESCENT L I1 (ED), (ING) Its ..INSIDE DIAMETER I. INSULATING GLASS )I ;; ANTERIOR INV }: "=INVERT f, .i,J0INT ; I : 1QIST .; CICKPLATE = KITCHEN 1.41�DDER , ,,Ll-AAG BOLT LAMINATE, (ED) -LGL :LAMINATED GLASS ` AV LAVATORY : LLEFT HAND LENGTH `LIGHT LINTEL LIVE LOAD Oc 'LOCATE LOUVER NAT NOM ; r;Jp NIC • NTS MANHOLE MANUFACTURE, (ER) MASONRY MATERIAL MAXIMUM MECHANIC, (AL) MEDIUM MEDIUM DENSITY OVERLAY MEMBER MEMBRANE METAL METER, (5) MIWMETER, (SS MINIMUM MIRROR MISCELLANEOUS MOLDING, MOULDING MOUNT, (ED), (ING) MOVABLE MULLION ATURAL OMINAL 'NOT IN CONTRACT NOT TO SCALE • . ABOVE ABOVE FINISHED FLOo ACCESS ACCESS PANEL ACOUSTICAL ACOUSTICAL TILE ADJACENT ADJUSTABLE AGGREGATE ALTERNATE ALUMINUM ANCHOR, ANCHORAGE ANCHORBOLT ARCHITECT, ARCHITECTURAL AREA DRAIN 'ASPHALT AWNING BACKER BEAM BEARING BEARING PLATE BELOW BETWEEN BEYOND BLOCKING BOARD BOTH SIDES BOTTOM BRACKET BRICK BUILDING BY OWNER ABBREVATIONS OC ON CENTER, (S) OPG OPENING OPH OPPOSITE HAND ORN ORNAMENTAL OD OUTSIDE DIAMETER OA OVERALL OH -OVERHEAD PNT PAINT, ED) PNL PANEL, (ING) PB PANIC BAR PTD PAPER TOWEL DISPENSER PTR PAPER TOWEL RECEPTOR PRPT PARAPET PTN PARTITION PVMT PAVEMENT PERF PERFORATE, (ED) PER PERIMETER PLTG PLANTING PLAS PLASTER PLA PLASTIC PLAM PLASTIC LAMINATE PL PLATE PG PLATE GLASS PWD PLYWOOD PD POUND,(S) PCF POUNDS PER CUBIC FOOT PLF POUNDS PER LINEAR FOOT PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PCC PRECAST CONCRETE PT PRESSURE TREATED PL PROPERTY UNE QT QUARRY TILE RAD RADIUS RFT RAFTER RL RAIL, (ING) REC RECESS. (ED) REF REFER, (ENCE) RFT_ REFLECT, (ED), (IVE), (OR) REG REGISTER REIN REINFORCE, (ED), (ING) REM REMOVE, (ABLE) REQ'D REQUIRED RA RETURN AIR REV REVISE, (5), REVISE, (ED) ROW RIGHT OF WAY RISER RD ROOF DRAIN RFH ROOF HATCH RFG ROOFING RM ROOM RO ROUGH OPENING ROK ROWLOCK RB RUBBER BASE SFGL SAFETY GLASS SCH SCHEDULE SCN SCREEN, (ED) SCUP SCUPPER SNT SEALANT STG SEATING SEC SECTION SVYD SERVICE YARD SHTH SHEATH, (ING) SHT SHEET SH SHELF, SHELVING SHNG SHINGLE, (S) SHU SHUTTER, (S) SIDG SIDING SIM SIMILAR SLO SLOPE SQL SOLDIER SC SOLID CORE SPC SPACE, (R) SPK SPEAKER SPEC SPECIFICATION SQ. SQUARE SST STAINLESS STEEL STD STANDARD ST STEEL STO STORAGE SF STOREFRONT SD STORM DRAIN STR STRUCTURAL ITCG STUCCO SFLR SUBFLOOR SA SUPPLY AIR SYD SIDE YARD SYN SYNTHETIC SYS SYSTEM TEL TELEPHONE T1/ TELEVISION TG TEMPERED GLASS TIG TEMPERED, INSULATED GLASS THK THICK, (NESS) TOR THRESHOLD TBRL TO BE RELOCATED TOBR TO BE REMOVED TPD TOILET PAPER DISPENSER TPTN TOILET PARTITION TSL TOP OF CONCRETE SLAB TC TOP OF CURB TJ TOP OF JOIST TP TOP OF PLATE TST TOP OF STEEL TSF TOP OF SUBFLOOR TW TOP OF WALL TOR TO REMAIN TR TRANSOM T TREAD TYP . TYPICAL UNF UNFINISHED UNO UNLESS NOTFTHERWISE UR URINAL U.31. UTTUTY VNR VENEER VERT VERTICAL VIN ANYL VB , BASE VCT VINYL COMPOSITION TILE VF VINYL FABRIC VT VINYL TILE WSCT WH WC , WHTR WP WST WWF WHS WIN WG WO WD WI SYMBOLS USED AS ABBREVIATIONS O AT SPACING OF B.M. 4. i 1 WAINSCOT WALL HUNG WATER CLOSET WATER HEATER WATERPROOFING WEATHERSTRIP, (ING) WELDED WIRE FABRIC WHEEL STOP WINDOW WIRED GLASS WITHOUT WOOD WROUGHT IRON BENCH MARK CENTER UNE CHANNEL NUMBER PERPENDICULAR PLATE ROUND SQUARE DRAWING TITLE SECTION DETAIL (ENLARGED) ELEVATION CEILING HEIGHT DOOR WINDOW FINISH MATERIAL KEYED NOTES REVISIONS . ELEVATION HEIGHT . . . EQUIPMENT • • WALL TYPE - --WALL TYPE LETTER EXISTING STRUCTURE CENTERLINE . NEW STRUCTURE CENTERLINE WALL LEGEND §;1„.02V6VAgateldgizAcilu .0‘0", 02020:0:05M1,10: : .. OMB. BJ'S RESTAURANTS, INC. 7755 CENTER AVENUE HUNTINGTON BEACH, CA 92647 PHONE 714.500.2400 SYMBOL LEGEND • ARCHITECT CARTER & BURGESS, INC. 1420 WEST MOCKINGBIRD LANE, SUITE 800 DALLAS, TEXAS 75247 -4925 PHONE: 214.920.8100 FAX: 214.688.0618 EMAIL: SCOTT.WINDLE@C -B.COM CONTACT: SCOTT WINDLE STRUCTURAL ENGINEER CARTER & BURGESS, INC. 1420 WEST MOCKINGBIRD LANE, SUITE 800 DALLAS, TEXAS 75247 -4925 PHONE 214.920.8100 FAX: 214.688.0618 EMAIL TRAV.SWEATMANRc -b.com CONTACT: TRAV SWEATMAN P -1 4 T.O. SLAB- REFERENCE POINT 100'- -O� �ELEVA1ION HEIGHT EQUIPMENT NUMBER/LEfIER DESIGNATION FULL HEIGHT PAR - 1110N 6' ABOVE CEILING. FULL HEIGHT PARTITION TO DECK ABOVE. PARTITAL HEIGHT PARTITION, REFER TO ELEVATIONS. ONE HOUR RATED WALL, UL LISTING U465 COOLER/FREEZER WALL, (N.I.C.) DASHED LINES: WALLS /ITEMS TO BE REMOVED. SCREEN UNES: ITEMS TO REMAIN. EXISTING FULL HEIGHT PARTITION TO REMAIN. CODE INFORMATION KITCHEN/ STORAGE AREAS: 2,936 SQ. FT RESTROOM AREAS: 485.2 SQ. FT TOTAL LEASED AREA: 10,66176 SQ. FT. PHONE FAX: EMAIL: CONTACT: PHONE: FAX EMAIL: CONTACT: FLOOR PLAN SCALE: 1 - =1 -0 DRAWING NUMBER SHEET NUMBER SECTION ID. NUMBER SHEET MERE SECTION IS LOCATED DETAIL LD. NUMBER SHEET WHERE SECTION IS LOCATED ELEVATION I.D. NUMBER SHEET WHERE SECTION IS LOCATED CEILING HEIGHT ABOVE FINISHED FLOOR DOOR NUMBER DESIGNATION WINDOW NUMBER DESIGNATION FINISH DESIGNATION TRIM ONLY ,...-COMMENTS, IF APPUCABLE KEYED NOTE DESIGNATION ON APPUCABLE SHEET C::) ,..„... ADDENDUM NUMBER REVISED AREA CLOUDED n A. BUILDING CODE CRITERIA BUILDING CODE: ;2006 -INTERNATIONAL BUILDING CODE W/ WASHINGTON AMENDMENTS ELECTRICAL CODE: • 2005 NATIONAL ELECTRICAL CODE MECHANICAL CODE 2006 INTERNATIONAL MECHANICAL CODE W/ WASHINGTON AMENDMENTS PLUMBING CODE: 2006 UNIFORM PLUMBING CODE W/ WASHINGTON AMENDMENTS FIRE PREVENTION CODE: 2006 INTERNATIONAL FIRE CODE W/ WASHINGTON AMENDMENTS ACCESSIBILITY CODE: OCCUPANCY: A -2 RESTAURANT CONSTRUCTION TYPE IIB SEAT COUNT 253 + PATIO B. BUILDING SQUARE FOOTAGE DINING AREA:: 5,213 5Q. FT. COOLER /FREEZER ENCLOSURES: 519 SQ. FT. LIST OF CONTACTS DESK :NEB BITTON DESIGN GROUP 29229 CANWOOD STREET, SUITE 105 AGOURA HILLS, CA, 91301 818.707,1908 818.707.1936 EDDY€':I TONDESIGN.COM EDDY BITTON PROJECT COORDINATOR CARTER & BURGESS, INC. 1420 WEST MOCKINGBIRD LANE, SUITE 800 DALLAS, TEXAS 75247 -4925 214.920.8100 214.688.0618 JUAN.BROUSSARD©C -B.COM JUAN BROUSSARD MEP. ENGINEER CARTER & BURGESS, INC. 1420 WEST MOCKINGBIRD LANE, SUITE 800 DALLAS, TEXAS 75247 -4925 PHONE 214.920.8100 FAX 214.688.0618 EMAIL KEVIN.SANCIBRIAN@C-B.COM CONTACT: KEVIN SANCIBRIAN • GENERAL PROJECT NOTES 1. APPROVED PLANS SHALL BE KEPT IN A PLAN BOX AND SHALL NOT BE USED BY WORKMEN. ALL CONSTRUCTION SETS SHALL REFLECT SAME INFORMATION. CONTRACTOR SHALL MAINTAIN ONE COMPLETE SET OF PLANS ON THE PREMISES IN GOOD CONDITION AT ALL TIMES. THIS SHALL INCLUDE ALL ADDENDA AND CHANGE ORDERS. 2. THE CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO STARTING ANY WORK AND SHALL BE RESPONSIBLE FOR ALL WORK AND MATERIALS INCLUDING THOSE FURNISHED BY SUBCONTRACTORS AND OWNER. 3. GENERAL CONTRACTOR TO REFER TO THESE DOCUMENTS AS WELL AS SPECIFICATIONS FOR IDENTIFICATION OF ALL OWNER SUPPLIED ITEMS. ALL ITEMS NOT MARKED BY OWNER' OR 'N.I.C.' (NOT IN CONTRACT) ARE TO BE SUPPLIED BY GENERAL CONTRACTOR. UNLESS NOTED OTHERWISE, ALL @TEMS ARE TO . BE INSTALLED BY GENERAL CONTRACTOR. 4. THE TERM *WORK* AS USED IN THESE NOTES SHALL INCLUDE ALL PROVISIONS AS DRAWN OR SPECIFIED IN THESE DOCUMENTS AS WELL AS ALL OTHER PROVISIONS SPECIFICALLY INCLUDED BY THE OWNER IN THE FORM OF DRAWINGS, SPECIFICATIONS, AND WRITTEN INSTRUCTIONS AND APPROVED BY THE ARCHITECT. GENERAL NOTES, RESPONSIBILITY SCHEDULE, FINISH SCHEDULE PLUMBING SEWER AND VENT ISOMETRIC DIAGRAM PLUMBING WATER AND GAS ISOMETRIC DIAGRAMS 02/11/08 REVISION 1 02/21/08 CITY PLMB CMNTS 5. BEFORE SUBMITTING A BID, THE CONTRACTOR SHALL VISIT THE PREMISES AND FAMILIARIZE HIMSELF WITH THE EXISTING CONDITIONS AND THE EXTENT OF WORK REQUIRED TO COMPLETE THE PROJECT. 6. BEFORE CONSTRUCTION BEGINS, THE CONTRACTOR SHALL VISIT THE SITE TO VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS AND SHALL NOTIFY THE ARCHITECT, IN WRMNG OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK AND SHALL BE RESPONSIBLE FOR SAME. 7. IF THE CONTRACT DRAWINGS ARE FOUND TO BE UNCLEAR, AMBIGUOUS OR CONTRADICTORY, THE CONTRACTOR MUST REQUEST CLARIFICATION FROM THE ARCHITECT IN WRRING BEFORE PROCEEDING WITH THAT PART OF THE WORK. 8. THE ARCHITECT SHALL BE AVAILABLE TO VISIT THE SITE WHEN REQUESTED. IF A CONDRTON EXISTS THAT REQUIRES OBSERVATION OR ACTION BY THE ARCHITECT OR ENGINEERS, THE CONTRACTOR SHALL NOTIFY THE OWNER AND ARCHITECT. 9. CONTRACTOR SHALL BE FAMILIAR WITH PROVISIONS OF ALL APPUCABLE CODES AND SHALL INSURE THE COMPLIANCE OF THE WORK WITH ALL LOCAL, STATE AND FEDERAL CODES. IN THE EVENT OF CONFLICT BETWEEN LOCAL, STATE AND NATIONAL CODES, THE MORE STRINGENT SHALL GOVERN. BEFORE COMMENCING WORK NOT SHOWN IN DOCUMENTS, BUT REQUIRED TO ACHIEVE FULL COMPLIANCE WITH CODES, CONTRACTOR SHALL NOTIFY OWNER AND ARCHITECT. 10. THESE DOCUMENTS DO NOT INCLUDE THE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. SAFETY, CARE OF ADJACENT PROPERTIES DURING CONSTRUCTION, COMPLIANCE WITH STATE AND FEDERAL REGULATIONS REGARDING SAFETY AND COMPLIANCE WITH REQUIREMENTS SPECIFIED IN THE OWNER /CONTRACTOR CONTRACT IS, AND SHALL BE, THE CONTRACTOR'S RESPONSIBILITY. 11. CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES AND SAFETY PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK. 12. DO NOT SCALE DRAWINGS. USE WRITTEN DIMENSIONS FOR ALL MEASUREMENTS. ALL DIMENSIONS ARE TO FACE OF STUD UNLESS OTHERWISE NOTED. 13. OWNER SHALL PAY ALL TAXES, SECURE ALL PERMITS AND PAY ALL FEES INCURRED IN THE COMPLETION OF THE PROJECT, INCLUDING BUT NOT LIMITED TO BUILDING PERMITS, WATER, ELECTRIC AND TELEPHONE SERVICE CONNECTION, CERTIFICATE OF OCCUPANCY SURVEY'S AND INSPECTIONS. 14. SCOPE OF WORK. THE CONTRACTOR SHALL INCLUDE AND PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, TRANSPORTATION AND PAY ALL EXPENSES INCURRED IN THE PROPER COMPLETION OF WORK UNLESS SPECIFICALLY NOTED TO BE THE WORK OF OTHERS. CONTRACTOR SHALL PERFORM ALL WORK NECESSARY FOR PRODUCING A COMPLETE, HABITABLE PROJECT, INCLUDING BUT NOT LIMITED TO SITE WORK, ARCHITECTURAL, ELECTRICAL PLUMBING AND HVAC. 15. THE BID PRICES SHALL INCLUDE EVERYTHING NECESSARY OR PROPER FOR PERFORMING AND COMPLETING THE WORK REQUIRED AS INDICATED BY THE PLANS AND SPECIFICATIONS, TO PROVIDE FINISHED WORK. ANYTHING OMITTED THEREFROM WHICH 15 CLEARLY NECESSARY FOR THE COMPLETION OF THE WORK OR ITS APPURTENANCE SHALL BE CONSIDERED A PORTION OF THE WORK ALTHOUGH NOT DIRECTLY SPECIFIED OR SHOWN ON THE DRAWINGS. 1 6. INSURANCE WORKMEN'S COMPENSATION, AS REQUIRED BY LAW, AND PUBLIC LIABILITY SHALL BE CARRIED BY THE CONTRACTOR. 17. GUARANTEE THE CONTRACTOR SHALL UNCONDITIONALLY GUARANTEE ALL MATERIALS, AND WORKMANSHIP FURNISHED OR INSTALLED BY HIM OR HIS SUBCONTRACTORS FOR A PERIOD OF ONE (1) YEAR FROM DATE OF ACCEPTANCE AND SHALL REPLACE ANY DEFECTIVE WORK WITHIN THAT PERIOD WITHOUT EXPENSE TO THE OWNER AND PAY FOR ALL DAMAGES TO OTHER PARTS OF THE BUILDING RESULTING FROM DEFECTIVE WORK OR ITS REPAIR. THE CONTRACTOR SHALL REPLACE DEFECTIVE WORK WITHIN TEN (10) DAYS AFTER R IS BROUGHT TO HIS ATTENTION. 18. PROTECTION: THE CONTRACTOR SHALL BE RESPONSIBLE FOR HIS WORK AND THAT OF HIS SUBCONTRACTORS FOR LOSSES AND DAMAGES TO EQUIPMENT, TOOLS AND MATERIAL USED IN CONJUNCTION WITH THE WORK AND FOR ACTS OF HIS EMPLOYEES. 19. CONTRACTOR IS TO PROVIDE TO THE OWNER A UST OF ALL SUBCONTRACTORS USED, COMPLETE WITH ADDRESSES, PHONE NUMBERS AND COPIES OF ALL WARRANTIES. 20. CONTRACTOR IS TO PROVIDE TO THE OWNER A UST OF ALL SUBCONTRACTORS USED, COMPLETE WITH ADDRESSES, PHONE NUMBERS AND COPIES OF ALL WARRANTIES. 21. THE TERM 'CONTRACTOR" AS USED IN THESE NOTES SHALL REFER TO THE GENERAL CONTRACTOR OR TO THE SUBCONTRACTORS. THE OWNER MAY ELECT TO CONTRACT DIRECTLY WITH A SUBCONTRACTOR FOR ANY PART OF THE WORK. NATIONAL ACCOUNT "NATIONAL ACCOUNT - OWNER HAS ENTERED NATIONAL ACCOUNT AGREEMENTS WITH VENDORS FOR SOME MATERIALS AND PRODUCTS. DEVELOPERS, LANDLORDS AND THEIR ARCHITECTS AND CONTRACTORS SHALL USE THESE VENDORS, WITHOUT SUBSTiTU•I1ON, FOR ALL PRODUCTS IDENTIFIED UNDER THE NATIONAL ACCOUNTS PROGRAM. BB'S •! o B tl FrMici • WESTFIELD SOUTHCENTER 1159 SOUTHCENTER MALL TUKWILA, WASHINGTON 98188 ..9 od&..ii�..✓y,�y:5.le��liT;+is33 4 i�.� .. DRAWING NUMBER: G1.0 SITE PLAN • • SITE LOCATION MAP BpS j •, r � r, . Pc' t •• • 7ai.W +i.•wr+.a..r i.t wi.L.W aa..W46.Y,'ia t1767y . r :76 rV _, 1 TRUE TRUE n ARCHITECTURAL EGRESS/FURNITURE PLAN ENLARGED FLOOR PLAN AND DETAILS EXTERIOR ELEVATIONS EXTERIOR ELEVATIONS /INTERIOR ELEVATIONS INTERIOR ELEVATIONS INTERIOR ELEVATIONS INTERIOR ELEVATIONS WALL SECTIONS WALL SECTIONS/DETAILS • • • • • • • • • WALL SECTIONS /DETAILS DETAILS (EXTERIOR) DETAILS DETAILS DETAILS • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • A1.6 A2.0 A2.1 A2.2 A2.3 A2.4 A3.0 A3.1 A3.2 A4.0 A4.1 A4.2 A4.3 A5.0 SP1,0 SP1.1 SP1.2 FOOD SERVICE: PLUMBING: MECHANICAL M1.0 M2.0 ELECTRICAL: TITLE, DRAWING INDEX, GENERAL NOTES. & .INFORMATION • SCHEDULES AND DETAILS OWNER CMNTS F CO0 , L O %e 5 �� p , Mai_ n :.SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical Iectrical Iumbing Ller Gas Piping City of Tukwila R! 11 " °ANN G DIVISION • • FILE COPY Permit NO. Pia!' review approval is Stabs to errors and ontlssIons- Approval of construction documents does not authorize the violation of an adopted code or ordnanze. Receipt of approved Fie is wedged: By Date: , --7- City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees . .. • • • • • • • • • • • • • • MECHANICAL FLOOR PLAN • • CarteriBurgess CARTER & BURGESS, INC. 1420 WEST MOCKINGBIRD LANE, #800 DALLAS, TEXAS 75247-4925 4934 REGISTERED ARCHITECT .;; SC f WI t. LE � F' SHIN ON T ' 3.11.2008 co CC ; 1- < C) Z Z 0 CC O I CI] 0 co 0 1- W O CO wze co 0 1-- 7755 CENTER AVE STE. 300 HUNTINGTON BEACH, CA. 92647 INLINE CO JOB NUMBER: 024203.014 DATE ISSUED: 01 -25 -08 FOR PERMIT ISSUES: HEALTH DEPT PERMIT CONSTRUCTION SHEET CONTENTS: SHEET NUMBER: G1.0 CITY RECEIVED APR 2 4 2008 PERMIT CENTER Nom- (f1- 11/30/07 01/25/08 03/11/08 REVISIONS: , REVISION 1 ` 3" 2/11/08 /\CITY PLMB CMNTS 2/21 /08 CITY MECH CMNTS 2/22/08 ACITY BUILD CMNTS 2/22/08 /CITY ELEC CMNTS 2/22/08 / \CLARIFICATIONS 2/22/08 OWNER CMNTS 2/22/08 ,, 8 ISSUED FOR CONST. 3/11 /08 TITLE, DRAWING INDEX, LEGENDS, GENERAL NOTES & INFORMATION UNIT M DEL CONNECTIONS (In,) APPRDX. SHIP T, ) INLET SUCTION DM EQUALIZER DRAIN SME090 1/2' DD 7/8' ID 1/4' OD 3/4' MPT • 190 UNIT MODEL CONNECTIONS (In.) APPROX. S (lb ) INLET SUCTN IO EXT. EQUALIZER DRAIN LET090 1/2' OD 7/8' ID 1/4' OD 3/4' MPT 64 REFRIGERATION LINES E F A 8 CD CONDENSER FAN MOTORS 2 AIR IN } MULTI--MK SYSTEM ALLOW 36" CLEAR AROUND UNIT "MULTI -RAK" #KMR-1OA MAIN DISCONNECT BREAKER SWITCH RAIN TIGHT FLEXIBLE CONDUITS BY ELECTRICAL CONTRACTOR CONTROL CIRCUIT WIRING CONDUIT u ELECTRICAL CONTROL PANEL ELECTRICAL CONTROL PANEL POWER FEEDER WIRING CONDUIT PLATFORM (BY G.C.) FINISHED ROOF R- REFRIGERANT PIPING CONNECTION SEQUENCE FOR INSTALLATION INSULATED SUCTION LINE & LIQUID LINE r COIL AIR FLOW JAIR FLOW `4rrrr (LOW TEMPERATURE ONLY '' ".�::;;;;,,, ELECTRIC HEATER SPIRALED AND " " "�% `'f TAPED ON FREEZER DRAIN UNE BY REFRIGERATION CONTRACTOR ALL DRAIN - CLINES REQUIRE A MINIMUM OF 1/2" FALL PER FT. NOTE: RUN EACH DRAIN SEPARATELY COPPER DRAIN LINE REFRIGERATION CONTRACTOR TO SEAL PENETRATION CONDENSATE DRAIN (TYPICAL) ESTIMATED WEIGHT (LBS.) 1,460 RAINLINE TO EXIT AT BACK OF COIL. EXIT FROM FREEZER AT EARLIEST POSSIBLE DISTANCE. COPPER UNION TO BE SUPPUED & INSTALLED BY PLUMBER. "P" TRAP PROVIDE AIR GAP BETWEEN DRAIN & DRAIN LINE. FLOOR SINK OR RECEPTOR 5 1 1 1 1 1 REFRIGERATION LINES 1 I 1 L. L CURB OPENING FOR REFRIGERATION RACK 1 PIECE GALVANIZED SHEET METAL CAP BY G.C. WITH ALL JOINTS 'WELDED SOLID. 2" UPTURN AT PENETRATIONS, AND 1 1/2" RIDGE DOWN CENTER OF CAP REQUIRED. 3/4" PLYWOOD BY G, C. PENETRATIONS BY RErRIG. CONTRACTOR ROOFING MATERIAL TO RUN UP UNDER CAP } FINISHED ROOF NOTE: RUN EACH DRAIN SEPARATELY CARDBOARD TAPED IN PLACE TO CONTAIN FOAM (BY REF. CONTRACTOR). �- AIR FLOW (LOW TEMPERATURE ONLY) ELECTRIC HEATER SPIRALED AND TAPED ON FREEZER DRAIN LINE BY REFRIGERATION CONTRACTOR 86' -8r5 ALL DRAIN LINES REQUIRE A MINIMUM OF 1/2" FALL PER FT. --68,5 I El ---5 �f�fl A.17 f A % ifs 1 TYPICAL ROOF PLATFORM DETAIL - FOR REFERENCE ONLY GENERAL & REFRIGERATION CONTRACTOR NOTES: 1. GENERAL CONTRACTOR TO PROVIDE PLATFORM AT CODE HEIGHT. 2. KEC TO PROVIDE SHEET METAL CAP (W/ HAT SECTION) WITH WATER TIGHT SOLDERED JOINTS. PLATFORM TO BE PITCHED FROM CENTER TOWARD SIDES TO PROMOTE WATER DRAINAGE. 3. KEC TO PROVIDE PITCH POCKET(S) IN THE PLATFORM WITH 2" HIGH COLLAR. 4. GC TO BACK FILL OPENING WITH HENRY'S #208 WET PATCH ROOF CEMENT AFTER COMPLETION OF REFRIGERATION PIPING. 5. REFRIGERATION CONTRACTOR TO SET RACK ON PAD WITH VIBRATION PADS UNDER RACK. KAIRAK TO SUPPLY APPROPRIATE NUMBER OF VIBRATION PADS FOR EACH RACK. 6. REFRIGERATION CONTRACTOR TO TAPE CARDBOARD IN PLACE AT BOTTOM OF ROOF TO CONTAIN TRIPLE EXPANDABLE FOAM. 7. REFRIGERATION CONTRACTOR TO CUT PENETRATIONS IN PLYWOOD DECK AS REQUIRED FOR REFRIGERATION LINES TO ENTER BUILDING. 8. REFRIGERATION CONTRACTOR TO FOAM PROOF PENETRATIONS WITH TRIPLE EXPANDABLE FOAM TO SEAL PENETRATIONS. SUGGESTED PLATFORM DETAIL COIL INSULATED SUCTION LINE & LIQUID LINE COPPER DRAIN UNE CONDENSATE DRAIN (TYPICAL) HENRY'S #208 WET PATCH ROOF ,CEMENT (BY G.C.) REH IGERAATION CONTRACTOR TO FOAM PENETRATION IN ROOF. PLATFORM CURBED OPENING FOR REFRIGERATION LINES EFRIGERATION CONTRACTOR TO SEAL PENETRATION RAINLINE TO EXIT 45' @ BACK OF COIL. EXIT FROM FREEZER AT EARLIEST POSSIBLE DISTANCE. COPPER UNION TO BE SUPPUED & INSTALLED BY PLUMBER. "P" TRAP PROVIDE AIR GAP BETWEEN DRAIN & DRAIN LINE. FLOOR SINK OR RECEPTOR A 12 15 FIXTURE INFORMATION DESCRIPTION Walk -In Cooler MODEL SME090 *C 218 SME174 D 130 E 37 F 37 Walk -In Freezer Beer Cooler 4Sec U/C Ref. #KRES -138R Hoshizaki I /M #KM -1601 MRH Hoshizaki I /M #KM -1601 MRH w m 19.7 8.3 21.9 2.9 * SYSTEM LARGER THAN TYPICAL BJ'S PROTOTYPE 35 20 -10 -20 35 20 35 20 PROVIDE (6) MOUNTING PADS TO BE SHIPPED LOOSE ROOF CAP SUPPLIED BY OTHERS SHIPPED WITH RACK CONDENSER FAN MOTORS 2 REFRIGERANT END I W Ce 404A 404A 404A 404A 404A 404A LISTED CONDENSING UNIT 1K93 FILE SA8705 MODEL NO. MAE2 --4E2 SERIAL NO. T.B.D. H Z H Z H S D COMPRESSOR INFORMATION MODEL PHYSICAL DATA UNIT COOLER DE IA L (SYS. "A B ") ZF08K4E 2.50 9.7 63.0 208 3 RATING @ 60 Hz RLA LRA V PH CS20K6E 3.00 10.4 75.0 208 3 CS33K6E 5.00 20.7 90.0 208 3 RS64C2E 0.75 7.7 37.0 208 1 Condenser Circuit Only 1 1 1 Condenser Circuit Only 0.75 0.75 ELECTRICAL END PHYSICAL DATA 4.7 4.7 208 208 1 1 MBH. (95'F) 23.7 9.1 44.4 7.4 23.4 23.4 SCROLL © HEAD PRESSURE CONTROL HERMETIC CRANK CASE HEATER FAN CYCLE SWITCH SEMI - HERMETIC DISCUS 1215 COIL INFORMATION 1 0 FAN RATING © 60 Hz HEATER EACH TOTAL V EACH TO AL V PH 3.3 6.6 208 10.5 21.0 208 1 E E 1 2e.e CCNtr£C ON C3 2 LET090 By KaiRak 2.0 4.4 0.4 2.0 8.8 1.6 E ELECTRIC (TIMED) H HOT GAS (TIMED) O OFF CYCLE (TEMP.) C.T.M. = COILS TO MATCH 208 208 115 NOTE: - ALL SYSTEMS ENGINEERED WITH R -404a REFRIGERANT. ANY BASES /COILS NOT SUPPUED BY KAIRAK MUST BE EQUIPPED WITH R404a EXPANSION VALVE. "COMPRESSOR MOTOR PROTECTED UNDER PRIMARY SINGLE PHASE PROTECTION." -- ICE MACHINE REMOTED CONDENSER LINE RUNS MUST NOT EXCEED 100' OR MANUFACTURES WARRANTY MAY BE VOID. - INSULATE ICE MACHINE DISCHARGE & DRAIN LINES. 7.8 20.9 7.8 41.8 208 208 1 1 F.I. F.I. F.I. ELECTRICAL INFO TIME CLOCK TOTAL LINE AMPS 81.9 79.9 82.0 L1 L2 L3 DTSXP240 21.0 21.0 11.4 DTSXP240 9.7 DTSXP240 41.8 9.4 11.7 20.7 7.7 5/8 3/8 9.4 9.4 * SUPPLY CODES: F.I. - FACTORY INSTALLED TXV/T /S M - MANUFACTURER EQUIPPED (TXV/T /S) T/S -- THERMOSTAT & SOLENOID BY KAIRAK L - EXP, T -STAT & SOLENOID SHIPPED LOOSE BY KAIRAK TXV - EXPANSION VALVE SHIPPED LOOSE BY KAIRAK SPECIFICATION UNE SIZE ACCESSORIES BASED CONNECTIONS AT THE RACK a a cn 3 c 1 1/8 1/2 3391 41.8 1 1/8 5/8 3291 7.7 5/8 3/8 6801 11.7 7/8 3/8 9027 5/8 3/8 9.4 19.8 24" ON FIELD CON J I verify verify 14.4 12" 43.0 36" 9.0 9" 18" 18" CONSTRUC PION NOTES FOR TRADES 1. GENERAL CONTRACTOR A. CONTRACTORS SHALL VERIFY ALL DIMENSIONS AND COORDINATE WITH OTHER TRADES. B. GENERAL CONTRACTOR SHALL PREPARE AND WEATHER PROOF THE PLATFORM AND CURBED OPENINGS. verify verify verify verify verify verify verify verify verify verify DMONS verify verify verify verify verify verify ITEM NO. 1 REMOTE REFRIGERATION PACKAGE. THE REFRIGERATION PACKAGE SHALL BE PRE -- ENGINEERED AND FACTORY ASSEMBLED UNIT, TRADE NAME "MULTI- RAK ", AS MANUFACTURED BY KAIRAK DIVISION OF ITW FOOD EQUIPMENT GROUP LLC, 500 S. STATE COLLEGE, FULLERTON, CA. 92831. PHONE (714) 870-8661, FAX: (714) 870 -1977 E- mail:Engineering ©Kairak.com CONTRACTOR SHALL FURNISH AND INSTALL WHERE SHOWN ON PLANS, ( 1 ) KAIRAK, U.L APPROVED "MULTI- RAK" AIR - COOLED REMOTE REFRIGERATION PACKAGE, MODEL KMR -1 O , WITH CONTROL PANEL 208 VOLTS, 3 PHASE, 60 HZ. REFRIGERATION SYSTEM SHALL BE HOUSED IN A WEATHER PROTECTED ENCLOSURE. THE FRAME, ENCLOSURE, AND PANELS SHALL BE FABRICATED OF GALVANIZED i ttL. ENTIRE FRAME SHALL BE PRE - ASSEMBLED, WELDED, CLEANED, AND PAINTED WITH A PRIME COAT OF ZINC CHROMATE THEN FINISHED WITH A COAT OF BAKED ENAMEL EPDXY BASED PAINT. THE CONDENSER SHALL BE SECTIONAL REMOVABLE, MULTI - CIRCUITED WITH RIFLED TUBE SLOTTED FINNED AND SHALL BE DESIGNED FOR 20 ETD. CONDENSER FAN MOTORS SHALL BE MOUNTED ON THE TOP OF THE ENCLOSURE. 1. REFRIGERATION UNITS A. AIR-- COOLED CONDENSING UNITS SHALL BE HERMETIC TYPE (COPELAND). EACH UNIT SHALL BE EQUIPPED WITH HIGH -LOW PRESSURE CONTROL, LIQUID DRIER, SIGHT GLASS AND HEAD PRESSURE CONTROL B. ALL COMPRESSOR UNITS SHALL BE NEW FACTORY ASSEMBLED TO OPERATE WITH THE REFRIGERANT SPECIFIED IN THE ENGINEERING SUMMARY SHEET. REFRIGERANT R --404a SHALL BE USED ON ALL COMMERCIAL TEMPERATURE UNITS AND LOW TEMPERATURE UNITS. 2. PRE - PIPING A. ALL REFRIGERANT LINES SHALL BE EXTENDED TO ONE SIDE OF THE PACKAGE IN A NEAT AND ORDERLY MANNER. SUCTION UNE FOR LOW TEMPERATURE UNITS MUST BE INSULATED WITH ARMAFLEX (3/4" THICK). B. ALL TUBING SHALL BE SECURELY SUPPORTED AND ANCHORED W Th CLAMPS. C. SILVER SOLDER AND /OR SIL-FOS SHALL BE USED FOR ALL REFRIGERANT PIPING. SOFT SOLDER IS NOT ACCEPTABLE. D. ALL PIPING TO BE PRESSURE TESTED WITH NITROGEN AT 300 PSI. AFTER THE CONDENSING UNIT AND COIL HAVE BEEN CONNECTED, THE BALANCE OF THE SYSTEM SHALL BE LEAK TESito WM1 ALL VALVES OPEN. 3. CONTROL PANEL A. THE PACKAGE SHALL HAVE FACTORY MOUNTED AND PRE -WIRED CONTROL PANEL COMPLETE WITH MAIN DISCONNECT BREAKER SWITCH, COMPRESSOR CIRCUIT BREAKERS, FUSES, CONTACTORS AND TIME CLOCKS WIRED FOR SINGLE POINT CONNECTION. B. ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL MAIN POWER LINES TO PANEL AND PROVIDE WIRE HARNESS WIRING FOR CONTROL AND DEFROST HEATER BETWEEN AND THE DEFROST CLOCK AND THE REFRIGERATION FIXTURES, ALL IN ACCORDANCE WITH THE WIRING DIAGRAM AND LOCAL CODES. 4. SAFETY CAUTION EACH SYSTEM AND EVAPORATOR IS SHIPPED UNDER NITROGEN PRESSURE. USE CAUTION AND EXERCISE SAFETY AT ALL TIMES WHEN PREPARING FOR FINAL HOOK -UP. 5. EVAPORATOR COIL EVAPORATOR COILS SHALL BE DIRECT EXPANSION TYPE FABRICATED OF COPPER TUBES WITH ALUMINUM FINS. ALL EVAPORATOR COILS SHALL BE PROVIDED WITH SOLENOID VALVE, THERMOSTATIC EXPANSION VALVE, AND THERMOSTAT. PIPED AND WIRED TO THE JUNCTION BOX FOR POSITIVE PUMP DOWN. 2. REFRIGERATION CONTRA TQR A. ALL COPPER TUBING TO BE REFRIGERANT GRADE A.C.R. OR TYPE "L B. SILVER SOLDER AND /OR SIL -FOS SHALL BE USED ON ALL REFRIGERANT PIPING. SOFT SOLDER IS NOT ACCEPTABLE. C. ALL PIPING TO BE PRESSURE TESTED WITH NITROGEN AT 300 PSI. AFTER THE CONDENSING UNIT AND COIL HAVE BEEN CONNECTED, THE BALANCE OF THE SYSTEM SHALL BE LEAK TESTED WITH ALL VALVES OPEN. D. THE COMPLETE SYSTEM SHALL BE EVACUATED WITH VACUUM PUMP. E. CHARGE, TEST, AND ADJUST EACH UNIT. F. REFRIGERATION CONTRACTOR TO PROVIDE AND INSTALL DRAIN LINE HEATER IN FREEZER TO BE CONNECTED BY ELECTRICAL CONTRACTOR G. REFRIGERANT SUCTION LINES OUTSIDE OF REFRIGERATED COMPARTMENTS, NOT RUN IN CONDUIT, SHALL BE INSULATED BACK TO COMPRESSOR WITH ARMSTRONG ARMA -FLEX AP- 25/50 FOAMED PLASTIC INSULATION OR EQUAL IN ACCORD WITH DIRECTION OF THE MANUFACTURER. MINIMUM THICKNESS SHALL BE 1/2 INCH FOR COMMERCIAL TEMPERATURE AND 3/4 INCH FOR LOW TEMPERATURE. 3. ELECTRICAL CONTRACTOR A. ELECTRICAL CONTRACTOR TO PROVIDE POWER FOR REFRIGERATION PACKAGE AND CONNECT CONTROL AND DEFROST SYSTEM AS CALLED FOR IN THE WIRING DIAGRAM. B. ELECTRICAL CONTRACTOR TO PROVIDE 4 -WIRE COLOR -CODED SERVICE FROM THE TIME CLOCK AT THE REFRIGERATION PACKAGE TO BLOWER COIL IN FIXTURE FOR AUTOMATIC DEFROST. C. ELECTRICAL CONTRACTOR TO CONNECT DRAIN -UNE HEATER IN FREEZER. D. ALL ELECTRICAL WIRING AND INSTALLATION SHALL BE IN ACCORDANCE WITH THE WIRING DIAGRAM AND LOCAL CODES. 4. PLUMBING CONTRACTOR A. PLUMBING CONTRACTOR TO PROVIDE TYPE "M" COPPER DRAIN OR WALK -IN REFRIGERATION AND FREEZER, PITCHED 1/2" PER FOOT OF RUN. IN FREEZER, UNHEATED DRAIN LINE MUST BE OUTSIDE OF INSULATION TO PREVENT FRFF7ING. TRAP DRAIN UNE OUTSIDE OF REFRIGERATED SPACE TO AVOID ENTRANCE OF WARM AND MOIST AIR. B. PLUMBING CONTRACTOR TO PROVIDE INDMDUAL DRAIN LINE FOR EACH .EVAPORATOR UNLESS OTHERWISE CALLED FOR. C. ALL PLUMBING INSTALLATION SHALL BE IN ACCORDANCE WITH LOCAL CODES. G.C. TO PROVIDE 6" X 6" PENETRATION FOR ELEC. CONNECTION TO RACK. �,.. k., te r ,' .ay.•j:r. _. � __ ",y - 4' .4n, 1:.:•:� „_' ..S.iAh.'v'u.Ir.. _. "ry+i.• .��'.vKlu�. i�L'?> r ...•�,i�� i _ __ _.., , '::'r::ilt:: ;:'Y..:,_ . ��s... • J.:. .0 � . '7.. 3� =i . ; -1�. •'l::i�zl':_.. _._ i�' _ n :;r ='�; , . - .�_ .�' ... . - , s. �'+ `7t "4�eE> . ,. ,ts•:kr:f't. � ��� .,�l+s.. ,N�, � .�'...: , �' �;.r• .... - •t�.r.9� .. .r_.nr.: t;>.ity�•` � .�f�:uR'�ll' MINK ENGINEERING S sn•• :L.r nCi •:i :.a:15.1Mc? _ :FA. 1 ::: 1' l- isit':f1c.. H3. 73Ir.. f.. x'q_- Ci1eP!..;',F:i ::1 • ' IS! . �:.: ±i: EFT• \. `. POWER SUPPLY: 208-230V/3PH/60HZ CONNECTED LOAD= 82.0 AMPS INGINMEIEEMIRAINEZEraft .. -+,;'%°„ il;:_ r YS::: tt .;,.:tis`.:1 ".r.'u. FUSE SIZE: 100 AMPS MINIMUM AMPACITY= 92.5 AMPS REV DESCRIPTION LEVEL A INITIAL RELEASE DATE 11/21/07 ✓ o 0 , Q Wo _z W.4 �' Z I--- Cr! ---- Q WO i g° J b ❑ O 0 Qp IZ> z L .I.I00 0 o z-l< aQ F= Y O w [L 0 owc v)0_CD g 0 0_ 3 : ‹C C) <0 � c..0 lY - d - 011UI: ` 1- 0 p uJ J 1- I= z a m DRAWN BY A. LAMUG DESIGNED BY A. LAMUG JOB NUMBER T.B.D. DRAWING NO. T.B.D. 1 OF SHEET $HL.t. I S to 1 fr en M06-117 TriMark Raygal Foodservice c Design, Equipment and Su r 9 Supplies 2719 WHITE ROAD IRVINE, CA 92614-6269 T E l 949 - 474 - 1 DDO FAX 949 - 474 -7298 E- NAIHRAVINGSOTRI NAMSA,CO1t This plan and the designs herein are the site property of Trimark Raygal and may not be reproduced, changed or used by anyone, in part or whole, without the m'lten n of a Trimark Raygal co npany officer. My desired this :w done. It the�resppo 'bT� anyone u this plan to read and become famfiar with all information shown hereon basing any It of notes. Measurements on this plan am from avcIIable a format on. Trimark Raygal wR not assume any responsibility Fabricators, contractors, for etc. usin this are to confirm an information on this plan with the job site. A information on this plan for the general contractor or the general con- tractor's subcanbractars to perform (plumbing, electrical, curbs, rolls, building openings, etc.) are for the sole purpose+ of equipment requirements; mfersnce is made to the owner or architectural plans for engineering or Ruling of items not suppied car Raygd. Trimark 87,71 will net assume nay aspen - thereof slaty shall be by the general contractor indudmg work roughing-in and final connections and all runs to equipment and in- cluding all fittings or any other parts materials or labor for such work. If any such work is in Trkrwrk Rcygal ccnhuct, d wal ink thus plan, a is not a � of Erna* Raygal con specifically and shall be provided by otters. Trimark Raygal assume no resporrfdy for work done by the general contractor or a subcontractor of the general contractor or any changes mode necessary by local codes (indudrng: Bw•Iding, Health Depart. orr5mcmces, Fire Depart, etc.) or changes by the owner, orchard or any otter wean outside of Tnmmk Raygal with c This changes and work of be completed e until appropriate corrections are made by Trimark Rayg (Wag this plan admit- tance that all information on this plan has been =mined and compared wr h other plans (example: archttecbnal inconsistencies, errors, ambiguities or omis- e� t � Raygal before completing bids or commencing any work hereunder. No additional allowance wdl be made for such work unless it is agreed before acceptance of bids. Plumbing or electrical parts not supplied with the equipment as a standard Ram shall be provided by the plumber or elechidan unless apecro ly Indicated on this plan. 02 -21 -08 Ill PROGRESS PRINT 11 -30 -01 10 HEALTH DEPT. PLAN CHECK ❑ BUILDING DEPT. PLAN CHECK ❑ BID SET ❑ CONSTRUCTION SET A DRAWN : SCALE : DESIGNER : CHECKED : TRII'1ARK RAYCsAL JOB NUMBER : 5131 SHEET TITLE RE1= RI6ERATI ON SYSTEM rPETA I LS SHEET NUMBER RECEIVED CITY OF TUKWWLA APR 2 4 2008 PERMIT CENTER TRIMARK R4TGAL TRIMARK RAYC'AL NOT TO SCALE K 7.1 UNIT MODEL N2, CONNECTIONS (in.) APPROX. SHIP VT, (Lbs.) - INLET SUCTION EXT. EQUALIZER DRAIN SME174 1/2' EID 1 -1/8' ID 1/4' OD 3/4' MPT 249 COLOR CODED DEFROST SYSTEM BLUE X ORANGE 4 BROWN 3 BLACK TERMINAL BLOCK LOCATED INSIDE ELECTRICAL PANEL AT THE RACK FIELD WIRING BY ELECTRICAL CONTRACTOR DRAIN LINE HEATER 9f - REFRIGERATION CONTRACTOR CONNECTION BY EC. r *- L J L R -2 LSV DRAIN LINE HEATER BY --� REFRIGERATION CONTRACTOR CONNECTION BY E.C. ETC BEM ®® COLOR CODED DEFROST SYSTEM X ORANGE 4 BROWN 3 BLACK natr= ETC • L$V aiiPPm LOOSE BEBE THE RACK FED ii3TALL BY RFF708. CONTRACTOR a UM BY BICTRICAL CONmACTO . DPOT g f4 ELEC RI AL CONTRACTOR 1 I _ .E 4 L, y - i - -- - r �1� !- I 1 I - -- � -4- -, r �- - - -�- 4- t -I -�, 1 LEGEND: 1. DTFD - -- DEFROST TERMINATION /FAN DELAY 2. DLH-- -DRAIN LJNE HEATER (2_40V) -- - 3. LSV--UQUID SOLENOID VAR. k 4. ETC--- ROOM TERMOSTAT 5. FACTORY WIRING 6. - ---- -- FIELD WIRING 7. FAN DELAY AND DEFROST TERMINATION: * RED TO "X" * BLUE TO T * BLACK TO F1" DLH L J R -2 FOR BEER COOLER FOR WALK -IN COOLER • V •• g • • V • • • • • HEATERS 7.8amps DTFD NOTE #7 J SUPPLIED L 2 K�AI • - FROM 'H2 TO 'N R-2 FOR WALK -iN FREEZER TERIANAL BLOCK G.E LOCATED THE RACK.. Fan WIRING BY E CONTRACTOR DRAIN GOON CONTR CONNECTION BY EC. LSV 1 1 L - -J FAN SYSTEM "A" LEGEND: 1. DTFD--- DEFROST TERMINATION /FAN DELAY 2. DU-I----DRAIN LINE HEATER 240V) 3. LSV - - -- LIQUID SOLENOID VALVE 4. ETC - - -- ROOM TERMOSTAT 6 FACTORY 6. FIELD IRIN 7. FAN DELAY AND DEFROST TERMINA11ON: * RED TO "X" * BLUE TO "N" * BLACK TO "F1" HEA 20.9cmps ELECTRIC DEFROST WIRING (DTSXP240) REFRIGERATION RACK CONTROL PANEL 208- 230V/3PH 60HZ SYSTEM "B" FIELD WIRING I BY ELECTRICAL CONTRACTOR DPDT SWITCH BY 1 ELECTRICAL CONTRACTOR (TERMINAL BLOCK AT EVAPORATOR COiL GROUND SUPPLIED BY KNRAK J FROM�F" TO 4' DLH 9E174 MELD WRING BY ELECTRICAL CONTRACTOR COLOR CODED DEFROST SYSTEM BLUE X ORANGE 4 BROWN 3 BLACK TERMINAL BLOCK LOCATED INSIDE ELECTRICAL PANEL AT THE RACK. FAN TOTAL 2.0 �� ELECTRIC DEFROST WIRING (DTSXP240) SYSTEM "C" TNa1E, ETC. LW SIBPPBD LOLhl£ BEIDE TIE RACK FIELD Vim) BY REMO. 03fiRAl:1Ot: - BY UECTRE N. CCN 1RACTOR. NOTE 17 SliV1.120 h3r IGSAK i2 EA ) 4 �1 ELECTRIC DEFROST WIRING (DTSXP240) TOTAL FAN NAPS 6.6 DPOT SWITCH ELECTRICA CONTRACTOR GROUND L1 L2 208-230V, 30, 60 Hz L3 TO MAIN POWER PANEL R -2 gY FIELD WIRING CONTRACTOR POWER PLAN MAIN DISCONNECT • 'x, • 100A LEGEND: 1. DTFD - -- DEFROST TERMINATION /FAN DELAY 2. DLH- -DRAIN LJNE HEATER 22(_40V) 3. LSV - - -- LIQUID SOLENOID VALVE 4. ETC ----- ROOM TERMOSTAT 5. FACTORY WIRING 6. --- - -- FIELD WIRING 7. FAN DELAY AND DEFROST TERMINATION: * RED TO '> *BLUU TO O�► * BLACK TO 1" o O o 1 30A SYSTEM eps`gr am.'- :f : i. V`:+ i` 7 ",£'Ou;-! • 1.826 1 :11�4i'�4 -�e7 f �r� lid 97.5 noun\ PHYSICAL DATA UNIT COOLER DETAIL (SYS. "C ") O f: 125 N o o f 0 0 •• nyti -= .Y.7t:. r'::f:!(w3ri 4"' 4 • 'tr•-e- : F};: i!:"i REFRIGERATION RACK © ROOF OR HIGHER LEVEL REFRIGERATION UNIT TYPICAL PIPING FOR VERTICAL RISERS 0 1 :11241<i1 i.1 i IftW6fAre7 REFRIGERATION LINE P -TRAP EVERY 7' PS (TYPICAL) P.S. 15A FAN CYCLE SWITCH FOR I/M SYS. E & F Hashlzald KM- 1601MRH t IREV LEVEL A DESCRIPTION INITIAL RELEASE DATE 11/21/07 0 0 F� 0_ Q Q w UO z 04 � wz • ALI I-- D - Q WWn_ .-I LI- a LI wim z WOO 0 . : z r ) ow ( I)�� W o Q ` A d O o New L1 0 Q Q 0 1 Z W < (n < 0 DRAWN BY A. LAMUG DESIGNED BY A. LAMUG JOB NUMBER T.B.D. DRAWING NO. T.B.D. 2 OF SHEET R � 2 SHEETS J skeile cock covetOce WO _ Mai co 0 LLJ D ct a a • .1 : .- At,,. . }.•: 1 T riMark Rayg& Foodservice E ui rvlce and Supplies Equipment an q P PP lies 2719 WHITE ROAD IRVINE, CA 92614 --6269 T E L 949 - 474 - 1000 FAX 949 - 474 -7298 E- YAIL;ORAIINGSOIRIYARKUSA.COY This plan and The designs herein are the sate property of Trimark Raygal and may not be reproduced, changed or used by argione, in part or whole. whthout the =lien of a Trimark Renal company officer. My desired ' ions to n this plan must be apprared in wrrang by Trimark Raygal before such work is done. It is the responsibility of anyone using this plan to read and become famgiar with all information shown hereon including any Est of notes. Measurements on this Plat are from mailable infomaton. Trimisic Raygal hail not assume any responsiluTity for the cocurncy of such information. Fabricators. contractors, etc. using this plea are to confirm all information on this plan vilh the job site. All information on this plan for the general canbroctor or the general con- - tractor's subcontractors to perform (plumbing, decbicai, curbs, wails, building openings, etc.) are for the sole purpose of equipment requirements; reference is made to the owner or architectural Pions for engineering or fisting of terns not sup_ried by Trimark Raygai. Trimark Rand el not assurer any nespon- sitaTdy for engineering thereof. All building work thereof shall be by the general contractor including all roughing -in and final connections and all runs to equipment and in- cluding all fittings or any other ports materials or labor for such work. If any such wed is in Tr n ark Raygat caibaat, d hri8 specifically be indicated on this plan; if it is not specifically indicated on this plan, K is not a part of Trunk Raygal cashed and shall be prarided by others. Trimark Raygol will assume no responsibility for work done by the general contractor or a subcontractor of the general contactor or any changes made necessary by local codes (indu Rng Building, Health Depart. ordinances, Fire Depart, etc.) or changes by the owner, architect err any other in outside of Trmhark Rcygal with authority to the design. This plan becomes void upon such changes and worts cannot be completed unfit the appropriate carrechons are made by Trimark Rayga. Using this plan is admit- tance that all 'shfonoa5on on this plan has been examined and compered with other plans (example: architectural plans) and any inconsistencies, errors, ambiguities or omis- sions have been reported to Trimark Raygd for wrdten cormctions before completing bids or commencing any work hereunder. No additional allowance will be made for such work unless R is agreed before acceptance of bids. Plumbing or electrical parts not supplied with the equipment as a standard item shall be provided by the plumber or decbidan unless specifically indicated on this plan. 02 -21_08 ® PROGRESS PRINT 11-30-01 IR HEALTH DEPT. PLAN CHECK ❑ BUILDING DEPT. PLAN CHECK DESIGNER : ❑ BID SET DRAWN : TRIMARK fRAYGAL CHECKED : TRiMARi( RAYGAL SCALE : NOT TO SCALE JOB NUMBER : 5131 SHEET TITLE RE RIGE1?.ATION vi°STe1 27ETAI1 -S SHEET NUMBER RECEIVED CiTY OF TUKWIIA APR 2 4 Z008 PERMIT CENTER ❑ CONSTRUCTION SET w 1..x_ W a. u 0 Li±i = z 5 1 2 M TRIMARIC RAYGAL � - 7 .2 M 1 �'`�'� d • 73 rri 0 , ,..,..... ., „. d '00 .1 1 V pm Z 9„ ' ® cm ® 0273 m I PLATFORM DETAIL w SLAB / CURB & DEPRESSION SYMBOLS N i"' ss 1 � 1 mat $ �_ � 1 ... . 1 . .,:• r . ,r. • • 0 • • � 10 ' `- i E 2 11 ,. 11 Il dIl N g;P il a;6 - g g g ij 0- I. s I— § 8 F 1� P -§ E d 6 1 1 . . .. �. - - fus s. _ - ! - .. , ....r ...w .e. _..._�.� :. ;= Z4 ∎Ui:i':xi1c CURB & DEP. CONTRACTOR NOTES ig g o _ 4` -S" q . • ,. S ; , >:...... -. �. ^• k''. �, <.'':. ,. y,:..: • .., r - 2 m g pi - m . E ., '' .f t . : j . 1 ,' ..r• �'r' i : r . •• '4 . T7T 17T ..-‹ P.% INSTALL ALL SY ALL SYMBOLS ON r 1 ° g k . .-- i 11 6 8 i SCALE 114 1-0' Tea glb rAws-,mr Arms ====== g iuror tip r ITWAVIOr mix 1 SYSTEM 'C' C:t .... _ . ... �..uay..:n ntt ut.::t: t nn:tttd: �.'. ::P ::1t I:: 'ttr .. ttt:t::tt :i1 :tt :: \ i r .... r . _m. �_.........•tnx:x. rut- ••••tnx :u:::r.•: :.a..._..r urn •• ......0 w N 1 0 0 z • it { I�n a I1 -2° 1 1 - 1 4 .......... ......... E. _. »5..._.. f i BJ'S RESTAURANT AND BREWHOUSE i WESTFIELD SOUTHCENTER 633 SOUTHCENTER PARKWAY SUITE R4 TUKWILA, WA 98188 ti Y. > I> > > > > > > > > > 6wm .... 000000 : .a:itxn i\ 2 11 .1 .1 EiEi 1 111k11E1 Eli € €E1 I 111 1 €{111 r [ ( :::m::x::::i::i::i:::mm::::o Intl 1 . Lalr) r ,•�-1 —t-, ---1 0 —4 () 3s rn r V 00 IV rn c t 1 • "Una ?:1391111N eor 8391411N 133HS EXISTING BRACED FRAME ri COSTING BEAM EXISTING BEAM EXISTING BEAM EXISTING BEAM 1 HOOD -5 530 LBS EXISTING BEAM EE.4 100 LBS x MAU -1 1250 LBS HOOD -3 332 LBSI a 0 EXISTING BEAM \ HOOD -4 306 LBS CM HOOD -2 280 LBS 100 LBS EXISTING BEAM EXISTING BEAM HOOD -1 385 LEIS a ■ EE-.1 EE4 100 LBS 100 LBS EXISTING BEAM R1U-1 2860 LBS EXISTING BEAM R1U -3 2860 LBS 1 1/2' MIL DECK - RE: METAL DECK NOTES EXISTING BEAM EXISTING BEAM 1 S ET EXISTING BRACED FRAME S1.1 EXISTING BEAM FRAMING PLAN SCALE: 3/16 " =1' -0" I l i i to ED m m PLAN NOTES 1. REFERENCE SHEET S3.0 FOR TYPICAL DETAILS AND SHEET S0.1 FOR GENERAL NOTES. 2 FINISH FLOOR ELEVATION 100' -0 = EXISTING r'r 3. F1ELD VERIFY EXISTING AND NEW SLAB LOCATIONS. M 8 CITY OF TUKWILA APR 2 4 2008 PERMIT CENTER caiier' Burgess CARTER & BURGESS, INC. 1420 WEST MOCKINGBIRD LANE, #800 DALLAS, TEXAS 75247 - 4925 00 CC LU 1 0 Cr 1- CO 0 CO Ci � C < 0 L 1- 7755 CENTER AVE STE. 300 HUNTINGTON BEACH, CA. 92647 TRINE 018 JOB NUMBER: 024203.014 DATE ISSUED: 01 -25 -08 FOR PERMIT ISSUES: HEALTH DEPT PERMIT CONSTRUCTION REVISIONS: AS, REVISION A CLAIRIFICATION SHEET CONTENTS: ROOF PLAN SHEET NUMBER: 51.1 11/30/07 01 /25/08 03/11 /08 02/11 /08 02/22/08 .so aernisinrams bv Jambe Older Barad& Ira