HomeMy WebLinkAboutPermit M08-122 - WESTFIELD SOUTHCENTER MALL - EXPRESSEXPRESS 1070 SOUTHCENTER MALL M08 -122 Parcel No.: 6364200010 Address: Suite No: Owner: Name: Address: Contact Person: Name: TIM SCHENK Address: 1120 E 80 ST , BLOOMINGTON MN Value of Mechanical: $60,000.00 Type of Fire Protection: SPRINKLERS /AFA CityOf Tukwila Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC -10/06 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 1070 SOUTHCENTER MALL TUKW Tenant: Name: EXPRESS Address: 1070 SOUTHCENTER MALL , TUKWILA WA WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD CA MECHANICAL PERMIT Contractor: Name: GREENWOOD CONSTRUCTION COMPLANY Address: 12637 S 265 WEST STE 100 , DRAPER UT Contractor License No: GREENCC973MW DESCRIPTION OF WORK: NEW AHU, THERMOSTAT, INTAKE HOOD, RELIEF HOOD, AIR CONDENSING UNIT, AND (2) NEW EXHAUST FANS EQUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 1 0 0 2 0 2 0 0 * *continued on next page ** M08 -122 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 800 541 -0821 Phone: Expiration Date: 07/10/2009 M08 -122 08/04/2008 01/31/2009 Fees Collected: $826.25 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 28 Thermostat 1 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 08 -04 -2008 Permit Center Authorized Signature: Signature: doc: IMC -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us LoiQi; Permit Number: M08 -122 Issue Date: 08/04/2008 Permit Expires On: 01/31/2009 Date: U -4 - 0 V I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or thepprformance of wor . - • authorized to sign and obtain this mechanical permit. Date: Print Name: i" This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M08 - 122 Printed: 08 -04 -2008 Parcel No.: 6364200010 Address: 1070 SOUTHCENTER MALL TUKW Suite No: Tenant: EXPRESS 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: M08 -122 Status: ISSUED Applied Date: 04/29/2008 Issue Date: 08/04/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 15: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the doc: Cond -10/06 M08 -122 Printed: 08 -04 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 16: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 17: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 18: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 19: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 20: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 21: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 22: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 23: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * * continued on next page ** M08 -122 Printed: 08 -04 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: 47"e Print Name: h) 4 7 / •P 6°4J )°/'-- doc: Cond -10/06 M08 -122 Date: c p-X./F. ordinances governing or local laws regulating Printed: 08 -04 -2008 • CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us SITE LOCATION Site Address: to `T o c',e.v.4lnCPrn*P Tenant Name: 1r)c>yr es , Property Owners Name: V∎1Cs iQ \d. CDTipoco_Ai Yr\ Mailing Address: ilf aO I IN AS1n li< Re:u.\Pvarci I..eS Pi \e CPI City Contact Person: E -Mail Address: Contractor Registration Number: Contact Person: 3 *yW\\e. e 1 4'r E -Mail Address: SK9 Viet Sccp trvviAnine . c-ptrvt Q:\Applications\Fonms- Applications On Linel3 -2006 - Permit Application.doc Revised: 9 -2006 bh • Building Permit No. Mechanical Permit No. Public Works Permit No. Project No. 9 0S-10( Plumbing /Gas Permit No. P0 v ►/ (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: (p.3C2y 2c - c'ac) 1 a Suite Number: g32. Floor: 1 New Tenant: ® Yes I I..No State Name: 71 Day Telephone: $ b 1 41 OR'Z] Mailing Address: (1zn Cask- 8dtin Stce_er, (31r norv,i I-4 SS42,a J City State E -Mail Address: vvxSla P \ cier S. Cen\ Fax Number: CISZI $S4 - '+4b9 State Company Name: S11 \\ e rvISh0Ck crA.6, ..C*C , tnt. Mailing Address: (p l?,cc st An kit ac t { C %I 1PS$P K`a/ � \A2. Cni. ' 0 t J City State Contact Person: � v.P, KP\4h Day Telephone: tol4 I5 1 4gs- 4-SSCI E -Mail Address: SY,P .0- ' i n ( 1 0 .\t,rpyv-1C\r t ct • C o w l Fax Number: 6:M- I S4 S' — 4 cSs Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Zip GENERAL CONTRACTOR INFORMATION (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: `rfts, P' . Mailing Address: City Day Telephone: Fax Number: Expiration Date: Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Sic vrY\SOf1OC . eex y\c 9 , inc.. Mailing Address:tol30 S ,kAlk- t\ ept t to ' \\L CAA '$3c21 City State Zip Day Telephone: Colt IsLK— Lc ? Fax Number: 401 1 I S4S - 45gsS Page 1 of 6 Valuation of Project (contractor's bid price): $ 425;000 Scope of Work (please provide detailed information): Will there be new rack storage? ❑ Yes Q:WpplicatioraTorms- Applications On Linel3 -2006 - Permit Application.doe Revised: 9 -2006 bh Existing Building Valuation: $ L;vh.A-'e4 Too ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes IN No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers la Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ® No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 Existing Interior Remodel Addition to Existing" ' Structure . " " New " - Type of Construction per IBC Type of. - Occupancy per IBC • l st Floor .''13o S 939 rd Floor 3'' Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck Valuation of Project (contractor's bid price): $ 425;000 Scope of Work (please provide detailed information): Will there be new rack storage? ❑ Yes Q:WpplicatioraTorms- Applications On Linel3 -2006 - Permit Application.doe Revised: 9 -2006 bh Existing Building Valuation: $ L;vh.A-'e4 Too ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes IN No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers la Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ® No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 PUBLIC WORKS PERMIT INFORMATION - 206 - 433 -0179 Scope of Work (please provide detailed information): Water District ❑ ...Tukwila ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate • Please refer to Public Works Bulletin #1 for fees and estimate sheet. ❑ ...Water District #125 ❑ ... ValVue ❑ .. Renton ❑ ...Sewer Availability Provided Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34 ") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size .. ❑...Water Only Meter Size ❑ ...Sewer Main Extension Public ❑ ...Water Main Extension Public Q:\Applications\Forms- Applications On Line0-2006 - Permit Application.doc Revised: 9.2006 bh Call before you Dig: 1- 800 - 424 -5555 ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line ❑ .. Highline ❑ .. Geotechnical Report ❑ .. Maintenance Agreement(s) ❑ .. Work in Flood Zone ❑ .. Storm Drainage • ❑ .. Renton ❑ .. Seattle ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ .. Right -of -way Use — Potential Disturbance ❑...Traffic Impact Analysis ❑...Hold Harmless — (SAO) ❑ ... Hold Harmless — (ROW) ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding WO # WO # WO # ❑ ...Deduct Water Meter Size Private Private FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip Page 3 of 6 Unit Type: Qty Unit Type: • ty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser 2% 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct _ Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall /Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig /Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm/Ind MECHANICAL PERMIT INFLATION - 206 - 431 -3670 Replacement .... ❑ Replacement .... ❑ MECHANICAL CONTRACTOR INFORMATION Company Name: °1713 Mailing Address: City State Zip Day Telephone: Fax Number: Expiration Date: Contact Person: E -Mail Address: Contractor Registration Number: Valuation of Mechanical work (contractor's bid price): $ OD Scope of Work (please provide detailed information): 9 yseu) rhYto1 ii\F-cyvv,sin trtava. e Iry re best hob c1 ai�c c - \c\erNs « 1/4 2 exhno..Ls} .3r■ Use: Residential: New .... ❑ Commercial: New .... Fuel Type: Electric ® Gas .... Other: Indicate type of mechanical work being installed and the quantity below: Q: Upplications\Fon s- Applications On Line13.2006 - Penn( Apptication.doc Revised: 9 -2006 bh Page 4 of 6 Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Z Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain S 3 Sinks Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Z Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Z Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and /or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets /outlets for specific gas PLUMBING AND GAS PIPING PERMIT INFORMATION - 206 - 431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: R. t,. Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Plumbing work (contractor's bid price): $ 1 S b()0 Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): e uJ0. — cX ?x e�S, �OWCL�DC1e 5 , d<'�h�■Yn l�Q.�Y1S LOCL- ctj � X'S - �J Building Use (per Int'l Building Code): 91Y1 Occupancy (per Int'l Building Code): YM Utility Purveyor: Water: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Q: Applieations\Fonns- Applications On Line'3 -2006 - Permit Application.doc Revised: 9 -2006 bh • • Sewer: Page 5 of 6 Date Application Accepted: ,t + I Z4 1 Date Application Expir n l l Z � { �c� ` (J Staff Initials: I Mailing Address: • • PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHOR ZED AGENT: Signature: Print Name: ° r t(Y\ 5t h CV Q:Uppiications\Fonms- Applications On Linet3 -2006 - Permii Application.doc Revised: 4.2006 bh Date: 24 P O� Day Telephone: 'dOIs41 -O$' 17A eo.S* ' E e&r *Z'l F, \ corn Vnq ) M N s's 2.0 City.) State Zip Page 6 of 6 Receipt No.: R08 -02825 ACCOUNT ITEM LIST: Description MECHANICAL - NONRES City of Tukwila Payee: GREENWOOD CONSTRUCTION Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 97418 661.00 RECEIPT Parcel No.: 6364200010 Permit Number: M08 -122 Address: 1070 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 04/29/2008 Applicant: EXPRESS Issue Date: Initials: WER Payment Date: 08/04/2008 09:01 AM User ID: 1655 Balance: $0.00 Account Code Current Pmts 000.322.102.00.0 661.00 Total: $661.00 Payment Amount: $661.00 5622 08/04 .9710 TOTAL 661.00 doc: Receipt -06 Printed: 08 -04 -2008 n .. yr , CC.PC na RECEIPT NO: R08 -01394 Payee: ELDER -JONES SET ID: S000001014 SET TRANSACTIONS: Set Member Amount ACCOUNT ITEM LIST: Description City 41 Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http:/lwww.ci.tukwila.wa.us D08 -235 2,346.50 EL08 -486 300.50 MO 1$2: 165.25 PGO8 -137 47.00 TOTAL: 2,859.25 Payment Check 51321 ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES SET RECEIPT TOTAL: Initials: JEM Payment Date: 04/29/2008 User ID: 1165 Total Payment: 2,859.25 SET NAME: Tmp set /Initialized Activities TRANSACTION LIST: Type Method Description Amount 2,859.25 2,859.25 Account Code Current Pmts 000.345.832.00.0 300.50 000/345.830 2,558.75 TOTAL: 2,859.25 1770 04/29 9711 TOTAL 2859425 Project: G,X pre SS Type of Inspection: r SM 4 bel. Address: / tli J )"( Al Date Called: Special Instructions: 0741 Ups /41 v 1 ? Date Wanted: r) I 0 "Z "aX �j n,L� PAL R equester: Phone No: - 3 () 3 - ?21 — 2.6 ( (4 0 INSPECTION RECORD Retain a copy with permit PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Approved per applicable codes. Corrections required prior to approval. COMMENTS: true LID L&pcc , Inspectdr: 1 Date: 10 3 Da ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: Project: �� rs Type e of InspectisAA ,jr-� s � �. - 4 aQ �, Address• / v sc./ Date Called: Special Instructions: Date Wanted: 4m, / Q -- 21-- "04 . p.m. Requester: Phone No: _ 3 6 343 ' q-1./ c ❑ Approved per applicable codes. INSPECTION RECORD Retain a copy with permit A405-1 PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Corrections required prior to approval. COMMENTS: C am) • j3 - - 1"C� -�►d Inspe tor: a d D a t e : El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: L/ Project_ i f( Type of Inspection: ---: 12 P, of , ' I Address! . t07 .C- 94 ( Called: Special Instructions: / Date Wanted: o- � a m� p.m. Requester: Phone No: . 303 — 5 -- 2 �3 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 E f Approved per applicable codes. INSPECTION RECORD Retain a copy with permit off PERMIT NO. (206)431 -3670 Corrections required prior to approval. COMMENTS: 5 p 1 Insp 1 Date : 7 ` J $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 4( Receipt No.: 'Date: Project: - frose-- Type of Inspectio , w... dvc, vi — ( Kj Ad ) ress: A I I Date Called: Spec Instructions: Date Wanted: M0-16 - 00 C)n.. p.m. Requester: Phone No 0 3- ci c - 7 c)1 to INSPECTION RECORD Retain a copy with permit PERMIT NO. INSPECTION NO. CITY-OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: Rawl 04..1c( A Inspe 'Date: I 10 iG -D 6 .00 REINSPECTION EE REQUIkED. Prior to inspection, fee must be �,• - id at 6300 Southcenter lvd., Suite 100. Call to schedule reinspection. Re - ipt No.: 'Date: COMMENTS: 4. Type of Inspection: / `-- -J Address: rd '70 J( 1 Date Called: Special Instructions: Date Wanted: 9 , _ Requester: >•� ` , /1 `t' L..ae • s ' r - • .r.. : {i. `;'^ ":acY t. Lw= . • % ...ir •,, ,..5.:,:t _ _ • Project: r re re*� // c �.]�..� �- Type of Inspection: / `-- -J Address: rd '70 J( 1 Date Called: Special Instructions: Date Wanted: 9 , _ Requester: Phone No: 3 03 `` /Z/ -- 2.L • INSPECTION RECORD 4 Retain a copy with permit OY ' r 2 INSPECTI N NO. PERMIT NO. / CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3470 Ei Approved per applicable codes. Corrections required prior to approval. r Inspector: Dater ",, El $60.00 REINSPECTION FE `REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: COMMENTS: Type of Inspection: Address: / b - 2 0 c ( . Ai 0 k L. Suite #: Contact Person: Special Instructions: Phone No.: 3c.- c - Permits: Occupancy Type: . • /---■ S t 6 j, 4- i -- Of- 1-0 LJ t)r) () -c \ ch„.7.g„ ( A- /•-•. -• • ...1 .•• • ••1•1 "TIN , c Pro='-(4 L e*Ay --k• c., i7 \ ,--_-_, ::, \ c HA" ),..,.;e ..<, o r-- ,.-- / ,- A I --e. i- ( r •. `"--, Project: ev 5 ,.. Type of Inspection: Address: / b - 2 0 c ( . Ai 0 k L. Suite #: Contact Person: Special Instructions: Phone No.: 3c.- c - Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre-Fire: Permits: Occupancy Type: , INSPECTION NUMBER 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 n Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT rections required prior to approval. PERMIT NUMBERS Inspector: iV Date: / f2 Z( Hrs.: $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word/Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 Complete / ACTIVITY NUMBER: M08 -122 DATE: 04 -29 -08 PROJECT NAME: EXPRESS SITE ADDRESS: 1070 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Ci Buildi g P'vision Public Works Comments: PLAN REVIEW /ROUTING SLIP Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) APPROVALS OR CORRECTIONS: Incomplete n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: Approved LA Approved with Conditions Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 • PERMIT COORD COPY • Fire revention C n n Permit Coordinator n Planning Division DUE DATE: 05-01-08 No further Review Required DATE: DATE: Not Applicable n DUE DATE: 05-29-08 Not Approved (attach comments) n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 USF£tG CO JR6290 06/27/2003 Until Cancelled $12,000.00 07/10/2003 Name Role Effective Date Expiration Date STONE, MICHAEL D PRESIDENT 07/16/2003 Amount FORBUSH, ALLISON L SECRETARY 07/16/2003 Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date TRAVELERS Untitled Page General /Specialty Contractor A business registered as a construction contractor with LI *I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. GREENWOOD CONSTRUCTION COMPANY Business and Licensing Information Name GREENWOOD CONSTRUCTION COMPANY Phone 8015760550 Address 12637 SO 265 WEST STE 100 Suite /Apt. City State Zip County Business Type CORPORATION Parent Company DRAPER UT 84065 OUT OF STATE UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Separation Date Previous License Next License Associated License Specialty 1 Specialty 2 602306206 ACTIVE GREENCC973MW CONSTRUCTION CONTRACTOR 7/10/2003 7/10/2009 GENERAL UNUSED Business Owner Information Bond Information Insurance Information • S Page 1 of 2 https: / /fortress.wa. gov /lni/bbip/Detail. aspx ?License= GREENCC973MW 08/04/2008 SECTION 230000 BASIC MECHANICAL REQUIREMENTS A. NOTE 1. THE ABBREVIATION ESD &C WHEREVER IT APPEARS IN THESE MECHANICAL DRAWINGS AND /OR SPECIFICATIONS SHALL REFER TO "EXPRESS STORE DESIGN AND CONSTRUCTION ". ANY REFERENCE TO TENANT'S PROJECT MANAGER OR FURNISHED BY ANY OF THE ABOVE REFERS TO ESD &C. 2. DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND ALL OTHER SPECIFICATION SECTIONS, APPLY TO THIS AND THE OTHER SECTIONS OF DIVISION 15. 3. THE CONTRACTOR FOR THIS DIVISION OF WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF HIS SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT IS THIS CONTRACTORS RESPONSIBILITY TO PROVIDE HIS SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 4. THIS CONTRACTOR IS RESPONSIBLE FOR SCHEDULING THE COMPLETION AND INSPECTION OF THIS WORK TO COMPLY WITH THE ESD &C SCHEDULE AND THE PROJECT COMPLETION DATE. 5. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTAL OF BID TO DETERMINE CONDITIONS AFFECTING THE WORK. ANY ITEMS WHICH ARE NOT COVERED IN THE BID DOCUMENTS OR ANY PROPOSED SUBSTITUTIONS SHALL BE LISTED SEPARATELY AND QUALIFIED IN THE CONTRACTORS BID. SUBMITTAL OF BID SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS AND ANY MODIFICATIONS WHICH ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS. FAILURE TO VISIT THE SITE DOES NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY IN PERFORMANCE OF HIS WORK. 6. REFER TO RESPONSIBILITY SCHEDULE ON SHEET M04.1 OF THIS SET FOR INFORMATION IN REGARD TO RESPONSIBILITY OF WORK OR ITEMS WHICH MAY AFFECT THE BID. B. GENERAL REQUIREMENTS 1. THIS CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION, INCIDENTALS AND DETAILS NECESSARY TO PROVIDE A COMPLETE MECHANICAL SYSTEM AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD OR ESD &C SHALL BE PROVIDED BY THIS CONTRACTOR. CLOSELY COORDINATE THE ENTIRE INSTALLATION WITH THE LANDLORD AND THE ESD&C PROJECT MANAGER, AS REQUIRED. 2. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY MATERIAL OR LABOR CALLED FOR IN ONE SHALL BE FURNISHED AND INSTALLED EVEN THOUGH NOT SPECIFICALLY MENTIONED IN BOTH. ANY MATERIAL OR LABOR WHICH IS NEITHER SHOWN ON THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS, BUT WHICH IS OBVIOUSLY NECESSARY TO COMPLETE THE WORK, AND WHICH IS USUALLY INCLUDED IN WORK OF SIMILAR CHARACTER, SHALL BE FURNISHED AND INSTALLED AS PART OF CONTRACT. 3. WHERE THE DRAWINGS OR SPECIFICATIONS CALL FOR ITEMS WHICH EXCEED CODES OR THE LANDLORD'S TENANT CRITERIA, THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING AND INSTALLING THE SYSTEM WITH THE MORE STRINGENT REQUIREMENTS AS DESIGNED AND DESCRIBED ON THESE DRAWINGS, UNLESS SPECIFICALLY NOTED OTHERWISE. 4. ALL WORK IN THIS SECTION SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING, AND REPAIRING. THIS CONTRACTOR IS RESPONSIBLE FOR PROVIDING SUFFICIENT SERVICE ACCESS TO ALL EQUIPMENT. 5. ALL WORK SHALL BE PERFORMED IN A NEAT PROFESSIONAL MANNER USING GOOD CONSTRUCTION PRACTICES. 6. UNLESS SPECIFICALLY NOTED OTHERWISE, MATERIALS, PRODUCTS, AND EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF, SHALL BE NEW, UNDERWRITERS LABORATORIES LISTED AND LABELED AND SIZED IN CONFORMITY WITH REQUIREMENTS OF STATE AND LOCAL CODES, WHICHEVER IS MORE STRINGENT. 7. THIS CONTRACTOR SHALL DO ALL CUTTING, CHASING AND CHANNELING REQUIRED FOR ANY WORK UNDER THIS DIVISION. CUTTING SHALL HAVE PRIOR APPROVAL BY ESD &C PROJECT MANAGER AND THE LANDLORD. ALL PATCHING SHALL BE BY G.C. AND SHALL MATCH THE SURROUNDING SURFACES. 8. THE MECHANICAL CONTRACTOR SHALL MAKE ALL FINAL MECHANICAL CONNECTIONS AS REQUIRED FOR A COMPLETE AND OPERATING SYSTEM. A. THE MECHANICAL CONTRACTOR SHALL NOTIFY THE GENERAL CONTRACTOR TO CONTACT ESD &C'S DESIGNATED COMPANY (EMS) FOR START -UP. (REFER TO SHEET MO2.3). C. CODES 1. ALL WORK SHALL CONFORM TO THE LANDLORDS' CRITERIA, THE STATE'S, COUNTY'S, CITY'S AND LOCAL CODES AND ORDINANCES, SAFETY AND HEALTH CODES, NFPA CODES, ENERGY CODES AND ALL OTHER APPLICABLE CODES AND REQUIREMENTS. THIS CONTRACTOR SHALL INQUIRE INTO AND COMPLY WITH ALL APPLICABLE CODES, ORDINANCES, AND REGULATIONS. THIS CONTRACTOR SHALL INCLUDE ANY CHANGES REQUIRED BY CODES IN THE BID AND IF THESE CHANGES ARE NOT INCLUDED IN THE BID, THEY MUST BE QUALIFIED AS A SEPARATE LINE ITEM IN THE BID. AFTER CONTRACT IS AWARDED, CHANGE ORDERS FOR INCREASED COSTS DUE TO CODE ISSUES WILL NOT BE ACCEPTED BY ESD &C. D. LICENSES, PERMITS, INSPECTIONS & FEES 1. THIS CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LICENSES, PERMITS, INSPECTIONS, AND FEES REQUIRED OR RELATED TO HIS WORK. 2. FURNISH TO THE ESD &C'S PROJECT MANAGER ALL CERTIFICATES OF INSPECTION AND FINAL INSPECTION APPROVAL AT COMPLETION OF PROJECT. E. TRADE NAMES, MANUFACTURERS AND SHOP DRAWINGS 1. WHERE TRADE NAMES AND MANUFACTURERS ARE USED ON THE DRAWINGS OR IN THE SPECIFICATIONS, THE EXACT EQUIPMENT SHALL BE USED AS A MINIMUM FOR THE BASE BID. MANUFACTURERS CONSIDERED AS AN EQUAL OR BETTER IN ALL ASPECTS TO THAT SPECIFIED WILL BE SUBJECT TO APPROVAL IN WRITING BY ESD &C'S PROJECT MANAGER THROUGH SHOP DRAWING SUBMITTAL PROCESS FOR ACCEPTANCE PRIOR TO INSTALLATION. THE USE OF ANY UNAUTHORIZED EQUIPMENT SHALL BE REPLACED AT THE CONTRACTOR'S EXPENSE. 2. GENERAL CONTRACTOR SHALL SUBMIT ONLY SUBSTITUTION REQUESTS TO ESD &C PROJECT MANAGER FOR APPROVAL SUBMISSIONS SHALL BE MADE EARLY ENOUGH IN PROJECT TO ALLOW FOUR (4) WORKING DAYS FOR ESD &C PROJECT MANAGER'S REVIEW WITHOUT CAUSING DELAYS OR CONFLICTS TO THE JOB'S PROGRESS. SUBMITTALS SHALL BEAR THE STAMP AND /OR THE SIGNATURE OF THE GENERAL CONTRACTOR AND THE SUBCONTRACTOR SHOWING THAT HE HAS REVIEWED AND CONFIRMED THAT THE SUBMITTALS ARE IN CONFORMANCE WITH THE CONTRACT DRAWINGS AND SPECIFICATIONS OR INDICATE WHERE EXCEPTIONS HAVE BEEN TAKEN. F. GUARANTEE 1. THIS CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORK PROVIDED UNDER HIS CONTRACT AND SHALL MAKE GOOD, REPAIR OR REPLACE AT HIS OWN EXPENSE, ANY DEFECTIVE WORK, MATERIAL, OR EQUIPMENT WHICH MAY BE DISCOVERED WITHIN A PERIOD OF 12 MONTHS FROM THE DATE OF ACCEPTANCE (IN WRITING) OF THE INSTALLATION BY ESD &C'S PROJECT MANAGER. EXTENDED WARRANTIES ARE AS SPECIFIED WITH INDIVIDUAL EQUIPMENT. 2. THE EQUIPMENT MANUFACTURER SHALL GUARANTEE AND PROVIDE A 12 MONTH GUARANTEE TO ESD &C FROM THE DATE OF ACCEPTANCE. THIS CONTRACTOR SHALL WARRANTY THE INSTALLATION OF THIS EQUIPMENT AND WILL BE RESPONSIBLE FOR ANY DAMAGE AND /OR MALFUNCTION CAUSED BY THE INSTALLATION. THIS CONTRACTOR SHALL NOT BEAR ADDITIONAL WARRANTIES BEYOND A COMPLETE WORKING SYSTEM. G. RECORD DRAWINGS 1. THIS CONTRACTOR SHALL MAINTAIN ONE SET OF DRAWINGS ON THE JOB SITE UPDATED WEEKLY TO RECORD ALL DEVIATIONS FROM CONTRACT DRAWINGS, SUCH AS: A. B. C. LOCATION OF CONCEALED PIPING VALVES AND DUCTS. REVISIONS, ADDENDUM, AND CHANGE ORDERS. SIGNIFICANT DEVIATIONS MADE NECESSARY BY FIELD CONDITIONS, APPROVED EQUIPMENT SUBSTITUTIONS, AND CONTRACTOR'S COORDINATION WITH OTHER TRADES. 2. AT COMPLETION OF THE PROJECT AND BEFORE FINAL APPROVAL, THIS CONTRACTOR SHALL MAKE ANY FINAL CORRECTIONS TO DRAWINGS AND CERTIFY THE ACCURACY OF EACH PRINT BY SIGNATURE THEREON. FAILURE TO KEEP THESE RECORDS WILL ALLOW ESD &C TO DIRECT THE GENERAL CONTRACTOR TO PROVIDE THESE RECORDS AT HIS EXPENSE PRIOR TO FINAL PAYMENT. H. DISCREPANCIES IN DOCUMENTS 1. DRAWINGS (PLANS, SPECIFICATIONS, AND DETAILS) ARE DIAGRAMMATIC AND INDICATE THE GENERAL LOCATION AND INTENT OF THE MECHANICAL SYSTEMS. WHERE DRAWINGS, EXISTING SITE CONDITIONS, SPECIFICATIONS OR OTHER TRADES CONFLICT OR ARE UNCLEAR, ADVISE THE GENERAL CONTRACTOR IN WRITING, PRIOR TO SUBMITTAL OF BID. THE GENERAL CONTRACTOR IS RESPONSIBLE TO ADVISE ESD &C'S PROJECT MANAGER, IN WRITING, OF VARIATIONS TO CONTRACT DOCUMENTS PRIOR TO SUBMISSION OF BID. OTHERWISE, ESD &C PROJECT MANAGER'S INTERPRETATION OF CONTRACT DOCUMENTS OR CONDITIONS SHALL BE FINAL WITH NO ADDITIONAL COMPENSATION PERMITTED. I. PHASING REQUIREMENTS N PHASE OF THE STORE'S G 1. THIS CONTRACTOR IS TO INCLUDE IN HIS BID ALL NECESSARY SERVICE REQUIRED OPERATING TO KEEP THE Q HVAC, PLUMBING AND SPRINKLER SERVICE IN OPERATION. CONTRACTOR MUST SCHEDULE IN WRITING WITH ESD &C'S PROJECT MANAGER AND THE LANDLORD ONE WEEK PRIOR TO ANY SHUT DOWN OF THE HVAC, PLUMBING OR FIRE PROTECTION SYSTEMS. J. DEMOLITION 1. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF THE DEMOLITION OF EXISTING WORK AND THE DEMOLITION PROVIDED BY THE GENERAL CONTRACTOR. COORDINATE WITH THE GENERAL CONTRACTOR ANY EXISTING EQUIPMENT REQUIRED TO BE LEFT INTACT. 2. THIS CONTRACTOR SHALL INCLUDE, AND WILL BE HELD RESPONSIBLE FOR, THE REMOVAL OF ALL EXISTING HVAC UNITS, HYDRONIC PIPING, REFRIGERANT RECAPTURE, EXHAUST FANS, ETC. AND ASSOCIATED ROOF CURBS NOT TO BE REUSED ON THIS PROJECT, UNLESS SPECIFICALLY NOTED OTHERWISE. CONTRACTOR MUST VERIFY WITH THE LANDLORD ALL PRESUMED ABANDONED EQUIPMENT, PIPES, DUCTWORK, AND EQUIPMENT PRIOR TO REMOVAL. ROOF CURBS SHALL BE REMOVED AND THE ROOF PATCHED. ALL EXTRANEOUS ITEMS IN THE SPACE OR ON THE ROOF NOT APPLICABLE TO THE NEW WORK MUST BE REMOVED AND ROOF /WALL /FLOOR PATCHED /REPAIRED TO MATCH EXISTING STRUCTURE. EXISTING ABANDONED PIPES, DUCTS, OR EQUIPMENT IN THE FLOOR, EMBEDDED IN CONCRETE OR OTHERWISE INACCESSIBLE ARE TO BE CUT OFT AND SEALED BELOW OR WITHIN FLOOR OR WALL LEVEL WHEN THEY ARE NOT TO BE REUSED IN THIS PROJECT. IF REQUIRED BY LANDLORD OR CODES, ABANDONED PIPING AND /OR DUCTWORK MUST BE REMOVED TO POINT OF ORIGIN. CONFIRM THE EXTENT OF DEMOLITION PRIOR TO BID AND INCLUDE IN BID PROPOSAL. K. SLEEVES 1. THIS CONTRACTOR SHALL PROVIDE SLEEVES TO PROTECT EQUIPMENT OR FACILITIES IN THE INSTALLATION. EACH SLEEVE SHALL EXTEND THROUGH IT'S RESPECTIVE FLOOR, WALL OR PARTITION AND SHALL BE CUT FLUSH WITH EACH SURFACE EXCEPT SLEEVES THAT PENETRATE THE FLOOR, WHICH SHALL EXTEND 2" ABOVE THE FLOOR. CONTRACTOR MUST COORDINATE THROUGH THE LANDLORD ANY CORE DRILLING OR CUTTING OF OPENINGS IN MASONRY FLOORS OR WALLS. 2. ALL SLEEVES AND OPENINGS THROUGH FIRE RATED WALLS AND /OR FLOORS SHALL BE FIRE SEALED WITH CALCIUM SILICATE, SILICONE "RTV" FOAM, " 3M " FIRE RATED SEALANTS OR EQUAL, SO AS TO RETAIN THEIR FIRE RATING. 3. SLEEVES IN BEARING AND MASONRY WALLS, FLOORS, AND PARTITIONS SHALL BE STANDARD WEIGHT STEEL PIPE FINISHED WITH SMOOTH EDGES. FOR OTHER THAN MASONRY PARTITIONS, THROUGH SUSPENDED CEILINGS, OR FOR CONCEALED VERTICAL PIPING, SLEEVES SHALL BE NO. 22 U.S.G. GALVANIZED STEEL MINIMUM. L. SCOPE OF WORK 1, THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE HVAC SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE EXPRESS TO THE FOLLOWING: A. B. C. D. E. F. G. 2. BEFORE STARTING WORK, THIS CONTRACTOR SHALL VISIT THE JOB SITE AND EXAMINE THE ARCHITECTURAL STRUCTURAL, MECHANICAL AND ELECTRICAL PLANS AND SPECIFICATIONS TO SEQUENCE, COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE HVAC SYSTEM, MATERIALS, AND EQUIPMENT WITH OTHER CONTRACTORS TO AVOID INTERFERENCES AND CONFRONTATIONS. 3. RELOCATION OF EXISTING DUCT MAINS OR BRANCHES TO MEET STORE DESIGN CRITERIA MUST BE INCLUDED IN BID PROPOSAL. M. HVAC EQUIPMENT 1. PRIMARY HEATING AND AIR CONDITIONING UNITS ARE TO BE FURNISHED BY ESD &C AS SCHEDULED UNLESS NOTED OTHERWISE. REFER TO PLANS FOR REQUIREMENTS. ALL EQUIPMENT SHALL INCLUDE A FIVE (5) YEAR COMPRESSOR AND TEN (10) YEAR HEAT EXCHANGER WARRANTY. 2. ALL EQUIPMENT SHALL BE COMPLETE IN EVERY RESPECT WITH ALL DEVICES AND ACCESSORIES PROVIDED TO MEET THE DESIGN INTENT AND OPERATION OF THE SYSTEMS SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN. 3. EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. N. 1. EQUIPMENT FURNISHED BY EXPRESS STORE DESIGN AND CONSTRUCTION THE FOLLOWING EQUIPMENT IS FURNISHED BY ESD &C AND INSTALLED BY THIS CONTRACTOR UNLESS SPECIFICALLY NOTED OTHERWISE. REFER TO RESPONSIBILITY SCHEDULE AND PLANS FOR APPLICABILITY. A. HVAC UNITS. B. TOILET EXHAUST FANS. C. DIFFUSERS, GRILLES AND REGISTERS. D. TEMPERATURE CONTROLS. 2. ALL DUCTWORK, ROOF OPENINGS AND CAPS NECESSARY TO PROVIDE A COMPLETE TOILET EXHAUST SYSTEM SHALL BE FURNISHED AND INSTALLED BY THIS CONTRACTOR. 0. CURBS FOR SUPPORT 1. THIS CONTRACTOR SHALL FURNISH AND INSTALL ALL NECESSARY CURBS REQUIRED TO INSTALL ALL HVAC EQUIPMENT AS DESCRIBED ON THE DRAWINGS. CURBS SHALL BE A MINIMUM OF 14 HIGH (SEE M04.1 "LOCAL AREA REQUIREMENTS" ITEM # 5), OF THE SAME MANUFACTURER OF THE EQUIPMENT UNLESS NOTED OTHERWISE. ALL CURBS SHALL BE INSTALLED SUCH THAT TOP OF CURBS ARE LEVEL. ALL PENETRATIONS OF EXISTING STRUCTURE SHALL BE DONE IN ACCORDANCE WITH THE LANDLORD'S GUIDELINES AT THIS CONTRACTOR'S EXPENSE. THIS CONTRACTOR SHALL RECEIVE ESD &C PROJECT MANAGER'S WRITTEN APPROVAL BEFORE ANY WORK TAKES PLACE. THIS CONTRACTOR IS ALSO RESPONSIBLE FOR ALL SEISMIC, HURRICANE OR OTHER SECURING DEVICES REQUIRED BY LOCAL OR OTHER CODES. P. LABELS/PIPE MARKERS SHALL BE A MINIMUM UNDER THIS CONTRACT. MARKERS SHALL ALL PIPES INSTALLED UN R 1. FURNISH AND INSTALL PIPE IDENTIFICATION MARKERS 1 -1/2" X 8" AND IDENTIFIED IN ACCORDANCE WITH THE BACKGROUND AND LETTER COLORS ISSUED BY THE AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI). 2. PIPING SHALL BE IDENTIFIED AS FOLLOWS: CHILLED WATER RETURN, CHILLED WATER SUPPLY, CONDENSATE, HOT WATER RETURN, HOT WATER SUPPLY, CONDENSER WATER RETURN, CONDENSER WATER SUPPLY, REFRIGERANT LIQUID, REFRIGERANT SUCTION, AND DIRECTIONAL ARROWS. ALL IDENTIFICATIONS MUST BE VISIBLE AT EQUIPMENT. Q. FINAL HVAC INSPECTIONS 1. ASIDE FROM NORMAL INTERIM INSPECTIONS OF WORK IN PLACE, ESD &C SHALL HAVE AN INDEPENDENT HVAC CONTRACTOR INSPECT THE FINISHED HVAC INSTALLATION UPON COMPLETION FOR COMPLIANCE WITH THE PLANS, SPECIFICATIONS AND CODES. THE INSTALLING CONTRACTOR WILL BE RESPONSIBLE TO BRING ALL ITEMS REPORTED BY THE INDEPENDENT HVAC CONTRACTOR UP TO PLANS AND SPECIFICATION REQUIREMENTS. END OF SECTION 230000 SECTION 230500 COMMON WORK RESULTS FOR HVAC A. HANGERS HVAC UNITS, ALL RELATED EQUIPMENT AND ACCESSORIES (UNLESS NOTED OTHERWISE). DUCTWORK, FITTINGS, DAMPERS, AND INSULATION. HYDRONIC PIPING. (AS APPLICABLE, REFER TO PLANS). REFRIGERANT PIPING (AS APPLICABLE, REFER TO PLANS). CURBS, ROOFING, AND STEEL FRAMING FOR SUPPORT (AS APPLICABLE, REFER TO PLANS). TESTING, ADJUSTING, AND BALANCING. KEEPING A RECORD SET AND PREPARE AS- BUILTS DRAWINGS. 1. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS ANGLE IRON, BANDS, C- CLAMPS WITH RETAINING CLIPS, CHANNELS, HANGER RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK. 2. HANGERS SHALL BE FASTENED TO BUILDING STEEL, CONCRETE, OR MASONRY, BUT NOT TO PIPING. HANGING FROM METAL DECK IS NOT PERMITTED. HANGERS MUST BE ATTACHED TO UPPER CHORD OF BAR JOIST. WHERE INTERFERENCES OCCUR, AND IN ORDER TO SUPPORT DUCTWORK OR PIPING, THE CONTRACTOR MUST INSTALL TRAPEZE TYPE HANGERS OR SUPPORTS WHICH SHALL BE LOCATED WHERE THEY DO NOT INTERFERE WITH ACCESS TO FIRE DAMPERS, VALVES, AND OTHER EQUIPMENT. HANGER TYPES AND INSTALLATION METHODS ARE ALSO SUBJECT TO LANDLORD CRITERIA. BE SIZED AND INSTALLED FOR THE OUTER DIAMETER OF INSULATION. INSTALL 6" LONG 3. HANGERS FOR ALL INSULATED PIPING SHALL _ SPLIT CIRCLE GALVANIZED SADDLE BETWEEN THE HANGER AND THE PIPE INSULATION. 4. HANGERS AND PIPING OF DISSIMILAR METALS SHALL BE DI- ELECTRICALLY SEPARATED. B. VIBRATION ISOLATION DEVICES 1. SPRING VIBRATION ISOLATION DEVICES SHALL BE FURNISHED AND INSTALLED IN ALL SUPPORTS BETWEEN VIBRATING EQUIPMENT (FANS, AIR HANDLERS, ETC.) AND STRUCTURE. ISOLATORS TO BE SIZED ACCORDING TO LOAD WITH A MIN. 1" DEFLECTION. VIBRATING EQUIPMENT HUNG FROM STRUCTURE SHALL BE ISOLATED WITH RUBBER AND SPRING DEVICES. VIBRATING EQUIPMENT SUPPORTED FROM FLOOR OR DECK SHALL BE ISOLATED WITH HOUSED SPRING MOUNT DEVICES. 2. EXAMINE DEAD LOAD AND OPERATING LOAD CONDITIONS WHEN SELECTING DEVICES. ADJUST FOR PROPER ALIGNMENT AND LOADING. AVOID "GROUNDING" THE ISOLATOR. 3. CHECK HANGER ROD SIZE FOR ALLOWABLE LOADS AT THE ISOLATING DEVICE AND AT THE UPPER AND LOWER ATTACHMENTS TO STRUCTURES, DUCTS, EQUIPMENT, ETC. 4. CONSULT MANUFACTURER FOR APPLICATION DATA. C. TESTING, ADJUSTING, AND BALANCING 1. TESTING, ADJUSTING AND BALANCING OF ALL WORK SHALL BE MADE BY AN INDEPENDENT CONTRACTOR WHO IS A CURRENTLY LICENSED ASSOCIATED AIR BALANCING COUNCIL (AABC) OR NATIONAL ENVIRONMENTAL BALANCING BUREAU (NEBB) BALANCING CONTRACTOR. NO OTHER BALANCE REPORTS WILL BE ACCEPTED. ALL BALANCING WORK MUST BE COMPLETE AND DONE IN ACCORDANCE WITH THE MOST RECENT STANDARDS OF THEIR SOCIETY AND AS A MINIMUM SHALL INCLUDE THE INFORMATION AS SHOWN IN THE AIR BALANCE REVIEW CHECKLIST IN THE GC PROJECT MANUAL. PAYMENT OF ALL COSTS FOR TESTING AND BALANCING SHALL BE INCLUDED IN THE BID. HOWEVER, IT WILL BE THE G.C. THAT WILL CONTRACT DIRECTLY WITH THE AIR BALANCING COMPANY. 2. FINAL TESTING, ADJUSTING AND BALANCING REPORT MUST BE COMPLETE AND SUBMITTED WITH FINAL CLOSE -OUT DOCUMENTS TO ESD &C 1 WEEK PRIOR TO MERCHANDISING DATE. 3. THE HVAC CONTRACTOR SHALL BE PRESENT FOR AIR BALANCE TO VERIFY ACCESSIBILITY TO ALL DEVICES, VERIFY ALL OPERATING SEQUENCES AND INSTALL NEW FILTERS IN ALL UNITS JUST PRIOR TO THE AIR BALANCE. THE COMPLETE AIR BALANCE SHALL TAKE PLACE WITH OUTSIDE AIR DAMPERS IN MINIMUM POSITION, EXCEPT AS NOTED OTHERWISE. HVAC CONTRACTOR SHALL ALSO INSTALL A NEW SET OF FILTERS ONE DAY PRIOR TO MERCHANDISING. 4. BALANCE LANDLORD MEDIA QUANTITIES TO WITHIN 5% OF THAT INDICATED ON THE DRAWINGS. ANY REQUIRED CHANGES IN SHEAVES, BELTS OR PULLEYS NEEDED TO ACHIEVE SPECIFIED FLOW RATES SHALL BE PERFORMED BY THE HVAC CONTRACTOR WITH NO ADDITIONAL COST TO ESD &C. 5. ALL CONTROL SEQUENCES SHALL BE TESTED (INTERLOCKED EQUIPMENT, SMOKE DETECTORS, SMOKE EVACUATION, ECONOMIZER, ETC.) AND OPERATING STATUS RECORDED IN THE BALANCE REPORT. AIR BALANCING CONTRACTOR IS TO CONFIRM OVERRIDE OF MINIMUM OUTSIDE AIR INTAKE UPON CO2 MONITORING CONFIRMATION. FOR CO2 MONITORING CONTACT, SEE CONTACT INFORMATION ON SHEET MO2.3. 7. THREE COPIES OF THE BALANCE REPORT SHALL BE SUBMITTED THROUGH THE GENERAL CONTRACTOR TO ESD &C FOR APPROVAL. THE GENERAL CONTRACTOR SHALL VERIFY THE COMPLETENESS OF THE REPORTS PRIOR TO SUBMITTING TO ESD &C. SUBMIT ONE COPY OF FINAL APPROVED AIR BALANCE REPORT TO MALL GENERAL MANAGER. 8. THE BALANCING CONTRACTOR SHALL PERFORM ALL APPLICABLE TESTING AND BALANCING FUNCTIONS REQUIRED FOR THE SYSTEM _ Q DESIGNED ON THESE DRAWINGS. ALL SYSTEMS UNABLE TO BE COMPLETELY BALANCED AT THE TIME OF ORIGINAL BALANCE MUST BE BALANCED IN FUTURE AT NO ADDITIONAL EXPENSE TO ESD &C THE BALANCING CONTRACTOR SHALL RECHECK ANY ITEMS THAT ESD &C DEEMS NECESSARY AT NO ADDITIONAL COST TO ESD &C. LVES -INCH AND SMALLER: CLASS 150, BODY AND UNION BONNET OF ASTM B 62 CAST BRONZE WITH EWABLE SOLID BRONZE WEDGE DISC, RISING STEM, SCREWED BONNET AND RE- N EQUAL SUBSTITUTION. 5 CAST IRON BODY, RENE :•s • 1. GATE VALV , ENDS, INTEGRAL SE • , BALL VALVES ARE ACCEPTE 2. GATE VALVES, 2 -1/2 INCH AND LARGER: C • STEM, FLANGED ENDS, AND RE- PACKABLE UNDER PR 3. SWING CHECK VALVES, 2 -INCH AND SMALLER: CLASS ��, AST BRO HORIZONTAL SWING, Y- PATTERN, RENEWABLE _ ___ DISC, AND HAVING THRE RONZE SEATS AND SOLID WEDGE DISC, RISING TH BED OR SOLDER ABLE UNDER PRESSURE. DY AND CAP CONFORMING TO ASTM B 62 WITH R SOLDERED ENDS. 4. SWING CHECK VALVE, 2 -1 AND LARGER: CLASS 125 CAST IRON BODY AND BOLTED CA', IZONTAL SWING, RENEWABLE BRONZE DISC, FLAN ' DS AND CAPABLE OF BEING REFITTED WHILE THE VALVE REMAINS IN THE LIN . 5. CO ON BALANCING AND SHUTOFF VALVES: BELL & GOSSETT CIRCUIT SETTER WITH LOCKING SET POINT. A CIRCUIT ALANCE WHEEL MUST BE INCLUDED WITH 0 & M MANUAL. TACO OR GRISWOLD ARE CONSIDERED AS EQUAL END OF SECTION 230500 SECTION 230700 HVAC INSULATION A. DUCTWORK INSULATION 1. FURNISH AND INSTALL INSULATION PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS, AND IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES. INSULATION MUST COMPLY WITH NFPA 90A. 2. DUCT SIZES SHOWN ON DRAWINGS ARE INSIDE CLEAR DIMENSIONS. ALL RECTANGULAR DUCTWORK (SUPPLY AND RETURN) SHALL BE INTERNALLY INSULATED WITH 1 THICK, 1 -1/2 LB. DENSITY LINER (C =0.28 0 75 DEGREE F). WHEN A COMPLETE DUCTED RETURN AIR SYSTEM IS INDICATED ON THE DRAWINGS, ONLY THE 15' -0" OF THE RETURN AIR DUCT CLOSEST TO THE AIR HANDLING UNIT IS TO BE INSULATED. LINER IS TO HAVE A COATED SURFACE EXPOSED TO AIRSTREAM TO PREVENT EROSION. APPLY ADHESIVES AND MECHANICAL FASTENERS AS RECOMMENDED BY SMACNA AND THE MANUFACTURER TO PREVENT LINER SEPARATION FROM THE DUCT. ALL TRANSVERSE EDGES TO BE COATED WITH ADHESIVE. 3. ALL OUTDOOR AIR (ROUND, OVAL, AND RECTANGULAR) AND ROUND /OVAL SUPPLY AIR DUCTWORK SHALL BE EXTERNALLY INSULATED WITH A MINIMUM OF 1 1/2" THICK, 1# DENSITY (R =5.6) DUCT WRAP WITH VAPOR BARRIER. VAPOR BARRIER IS TO BE MAINTAINED THROUGHOUT DUCT SYSTEM, EXCEPT LINED DUCTWORK U T DUCTWORK. ALL JOINTS MUST BE AND EXHAUST SPECIFIED ELSEWHERE _ OVERLAPPED AND TUCKED SO THAT NO INSULATION FIBER IS VISIBLE. EXTEND DUCTWORK INSULATION WITHOUT INTERRUPTION THROUGH WALLS, FLOORS AND OTHER PENETRATIONS. 4. ALL INSULATION SHALL HAVE A FLAME SPREAD RATING OF NOT MORE THAN 25 AND A SMOKE DEVELOPED RATING OF NO HIGHER THAN 50 WHEN TESTED IN ACCORDANCE WITH ASTM E 84 -05, OR AS REQUIRED BY LOCAL CODES. IC PIPING INSULATION 1. ALL HYDRONIC PIPIN •' MILLED WATER AND /OR HEATING WATER (NOT INCLUDING CONDENSER WAT • SS SPECIFICALLY NOTED OTHERWISE), VALVES, FITTINGS, CESSORIES SHALL BE INSULATED. FOR PIPE SIZES INCHES, INSULATE WITH 1 INCH THICK (K = =023 0 75'F) FIBERGLASS INSU ITH ALL SERVICE JACKET AND +' BARRIER. FOR PIPE SIZES 2 -1/2 INCHES AND LARGER, INSULATE WITH 1 -1/2 INCH THICK (K =0.23 FIBER •. 'SULATION WITH ALL SERVICE JACKET AND VAPOR BARRIER. 2. INSULATION AT ALL HANGERS FOR PIPING 2 1 3. ALL INSULATION SHALL HAV 50 TO CONFORM REQUIREMENTS OF THE NFPA. AND LARGER SHA_ _. .ARD AND NON - COMPRESSIBLE. E SPREAD RATING OF NOT MORE THAN 25 AND A SMOKE ' 'PED RATING OF NO HIGHER THAT E ZESTON OR EQUAL INSULATION FITTINGS FOR ALL TEES, ELLS OR SPECIALTY FITTINGS. C. REFRIGERANT PIPING INSULATION 1. INSULATE THE REFRIGERANT SUCTION LINES AND CONDENSATE LINES WITH RUBATEX OR ARMSTRONG 1 INCH THICK PIPE INSULATION WITH FLAME SPREAD RATING OF NOT MORE THAN 25 AND A SMOKE DEVELOPED RATING OF NOT MORE THAN 50 IN ACCORDANCE WITH INDUSTRY STANDARDS. DO NOT INSULATE THE HOT GAS (LIQUID) LINES OR ANY HOT GAS BYPASS. END OF SECTION 230700 SECTION 230900 INSTRUMENTATION AND CONTROL FOR HVAC A. WORK RESPONSIBILITY 1. ESD &C HVAC SUPPLIER WILL FURNISH NECESSARY CONTROL DEVICES TO THE FIELD. FOR ALL DEVICES NOT FACTORY INSTALLED, IT WILL BE THE MECHANICAL CONTRACTOR'S RESPONSIBILITY TO INSTALL. ECTION 232100 RONIC PIPING AND PUMPS BE PRESSURE TESTED WITHOUT LEAKAGE AT A ONNECTED TO THE HVAC PI ILL TENANT'S SYSTEM WITH STEM. CONTRACTOR S UCTED TO DO SO F EST JOINTS POS S OR SHALL M ONIC PIPING 4 D INSTALL A COMPLETE HYDRONIC PIPING SYSTEM IF APPLICABLE. REFER TO PLANS TO DETERMINE IF A HYD FCC CHILLED WATER, CONDENSER WATER AND /OR HEATING WATER SHALL BE PLAIN ENDS. INSTALL STEEL PIPE WITH WELDED JOINTS WHERE PIPE I H THREADED JOINTS AND FITTINGS. INSTALL TYPE " K " COPPER PIPE F S BETWEEN DISSIMILAR METALS. ALL PIPING SHALL BE IN STRICT C WHICHEVER IS MOST STRINGENT. UNIONS OR FLANGES MUST B AY BE REQUIRED. ND OF SECTION 232100 AT T S PLUG) - 1/4 INCH NPT Fl AND CAPS SHALL BE BRASS WITH ERS, 125 PSIG, CAST IRON BODY WITH PERFORATE ED FOR 2 -1/2 INCHES AND LARGER. SCREEN OPENING ONDENSER WATER. PROVIDE WITH BLOWDOWN VALVE WITH INS WITHOUT PITCH. USE ECCENTRIC REDUCING COUPLINGS AT CHANGES IN SIZE 0 UNITS BELOW MAINS TO BE TAKEN FROM BOTTOM OF MAINS AT A 45 DEGREE ANGLE, PITCH ANCHES TO UNITS ABOVE MAINS TO BE TAKEN FROM TOP OF MAINS AT A 45 DEGREE ANGLE PITCH S UNITS. PITCH NOT LESS THAN 1" TO 10 FEET. EE MECHANICAL DETAIL DRAWINGS FOR APPLICABLE DETAILS. PROVIDE UL LISTED FIRE STOPPING SYSTEM AROUND ALL PIPING PENETRATIONS THROUGH RATED WALLS. PENETRATIONS SH MEET THE REQUIREMENTS OF UL DETAILS WL1001 (UNINSULATED WALL) AND WL5039 (INSULATED WALL). H OR END OF SECTION 230500 A. HYD 1. 1. 2. FURNISH IS REQUIRED. 2. PIPING A. HYDRONIC PIPI BLACK STEEL PIPE INSTALL STEEL PIPE PROVIDE DIELECTRIC UN LANDLORD'S REQUIREMENT SERVICE OR REMOVAL B. ALL PIPING AND EQUIPMENT SHAL C. ALL HYDRONIC PIPING AND EQUIPMENT CLEAN, AND REPLACE STRAINER SCREENS. PRIOR TO CONNECTION TO THE LANDLORD'S LANDLORD'S SYSTEM UNLESS SPECIFICALLY INS THRU A CHASE OR SHAFT WILL BE DONE WITH F AVAILABLE. SHOULD A JOINT BE REQUIRED, CONTRA D. PRIOR TO CONNECTION TO THE LANDLORD'S SYSTEM, CO FIELD REPRESENTATIVE, THAT ALL TESTING, FLUSHING, AND ACCORDANCE TO THE LANDLORD'S REQUIREMENTS AND T LANDLORD'S SYSTEM. 3. PIPING SPECIALTIES A. PRESSURE /TEMPERATURE TEST PLUGS (PET PRESSURE PROBE, 1/8 INCH O.D. FITTI 200 DEGREES F. B. STRAINERS - " Y " PATTERN STR 2 INCHES AND SMALLER, FLA 1/8 INCH FOR CHILLED OR 4. GENERAL INSTALLATION A. B. C. PIPING C. INSTALL WATER SAME ELEVATIO BRANCHE UNITS. TOW SECTION 232300 REFRIGERANT PIPING A. REFRIGERANT PIPING: 3. INSTALLATION 4. INSPECTION ALL ELBOWS ARE TO BE LONG RADIUS TYPE. END OF SECTION 232300 SECTION 233100 HVAC DUCTS AND CASINGS IMUM PRESSURE OF 125 PSI. IC SYSTEM E ASTM 53, SCHEDULE 40, ERW, S 2- /2 INCH AND LARGER. OR INCH AND SMALLER PIPE. ORMANCE WITH ASTM, ASA, AND SED AT EQUIPMENT CONNECTIONS PING SYST SHALL BE CLEANED AND FLUSHED. REMOVE, TH DOM IC WATER AND VENT ALL PIPING AND EQUIPMENT HALL � T FILL TENANT'S SYSTEM WITH WATER FROM THE FRO THE LANDLORD'S FIELD REPRESENTATIVE. ANY RUNS E USING THE LONGEST LENGTH OF HARD COPPER PIPE E ALL EFFORTS TO KEEP THE JOINTS IN ACCESSIBLE AREAS. SHALL OBTAIN WRITTEN CONFIRMATION FROM THE LANDLORD'S OPER FILLING OF THE TENANT'S SYSTEM HAS BEEN COMPLETED IN TENANT'S SYSTEM IS READY TO BE CONNECTED TO THE GS TO RECEIVE EITHER A TEMPERATURE OR LVE CORE OF NORDEL, RATED AT 400 PSIG, 0 TO STAINLESS STEEL SCREEN, THREADED FOR E AT 0.033 INCH FOR HEATING AND HO END FITTING. TH THE TOP OF PIPES AT OWNWARD TOWARD UPWARD THIS CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE REFRIGERANT PIPING SYSTEM BETWEEN THE INDOOR FAN UNITS AND OUTDOOR CONDENSING UNITS. REFER TO PLANS TO DETERMINE IF A REFRIGERANT SYSTEM IS REQUIRED. NEW PIPING IS REQUIRED. REUSE OF EXISTING PIPING IS NOT ALLOWED. A. REFRIGERANT PIPING SHALL BE TYPE ACR COPPER TUBING. TUBING SHALL BE CLEAN AND CLEAR OF DEBRIS, AND EVACUATED WITH A DEEP VACUUM PRIOR TO REFRIGERANT CHARGE. THE CONTRACTOR SHALL CONFIRM THE DIAMETER OF THE REFRIGERANT PIPING RUNS IN EXCESS OF 50 EQUIVALENT FEET WITH THE ARCHITECT, ENGINEER, AND MANUFACTURER FOR ALL SPLIT SYSTEMS. NO REFRIGERANT PIPING RUNS EXCEEDING 100 EQUIVALENT FEET ARE TO BE INSTALLED WITHOUT EXPRESS BRANDS' PERMISSION. THE MANUFACTURER SHALL PROVIDE ALL FINAL PIPE SIZING AND COIL SELECTIONS FOR ALL REFRIGERANT PIPING SYSTEMS. B. ALL FITTINGS AND JOINTS SHALL BE WROUGHT COPPER OR CAST BRONZE (ANSI B16.22). ALL COPPER TO COPPER JOINTS SHALL BE BRAZED WITH A COPPER - PHOSPHORUS ALLOY AND ALL OTHER JOINTS SHALL BE BRAZED WITH SILFOS -5 ALLOY. A. REFRIGERANT PIPE SIZING SHALL BE THE RESPONSIBILITY OF THE HVAC SUPPLIER. CONTRACTOR WILL PROVIDE A SCHEMATIC PROPOSED LAYOUT OF THE SYSTEM INCLUDING ALL ELBOWS, RISES, RUNS, ETC., WITH DIMENSIONS. THE HVAC SUPPLIER WILL THEN PROVIDE WRITTEN DOCUMENTATION OF PIPE SIZES AND ADDITIONAL REQUIRED SYSTEM COMPONENTS TO THE FIELD. B. SUCTION LINES SHALL HAVE ADEQUATE LIFT TRAPS AND /OR DOUBLE SUCTION RISERS TO MEET THE REQUIREMENTS OF FIELD CONDITIONS AND EQUIPMENT MANUFACTURER'S RECOMMENDATIONS. C. BRAZE ALL JOINTS WITH SILFOS -5 STARTING AT THE INDOOR UNIT AND WORKING TOWARD THE OUTDOOR UNIT. THE SEALS ON THE OUTDOOR UNIT SHALL BE BROKEN LAST. A NITROGEN BLEED SHALL BE USED DURING ALL BRAZING AND ANY TIME THE SYSTEM IS OPEN. ALL OPEN LINES SHALL BE CAPPED AND SEALED BEFORE LEAVING THE SITE DURING CONSTRUCTION. PRESSURE TEST FOR LEAKS WITH AN INERT GAS UP TO 245 PSIG. REDO LEAKING JOINTS AND RETEST UNTIL SYSTEM IS TIGHT. EVACUATE ENTIRE SYSTEM TO 200 MICRONS OF MERCURY. CHARGE SYSTEM WITH 25 PSI OF R -22 AND A INERT GAS TO 245 PSI AND RETEST SYSTEM. ENERGIZE CRANK CASE HEATERS 24 HOURS PRIOR TO STARTING COMPRESSOR TO ENSURE THAT ALL REFRIGERANT LIQUID IS OUT OF THE COMPRESSOR. D. UPON COMPLETION OF TESTING, BUT BEFORE THE REFRIGERANT PIPING INSULATION IS APPLIED, THE PIPING MUST BE INSPECTED BY A REPRESENTATIVE OF THE LOCAL GOVERNING AUTHORITY AS NECESSARY. E. INSULATE THE REFRIGERANT SUCTION LINES AND CONDENSATE LINES WITH RUBATEX OR ARMSTRONG 1 INCH THICK PIPE INSULATION WITH FLAME SPREAD RATING OF NOT MORE THAN 25 AND A SMOKE DEVELOPED RATING OF NOT MORE THAN 50 IN ACCORDANCE WITH INDUSTRY STANDARDS. DO NOT INSULATE THE HOT GAS (LIQUID) LINES OR ANY HOT GAS BYPASS. F. PROVIDE UL LISTED FIRE STOPPING SYSTEM AROUND ALL PIPING PENETRATIONS THROUGH RATED WALLS. PENETRATIONS SHALL MEET THE REQUIREMENTS OF UL DETAILS WL1001 (UNINSULATED WALL) AND WL5039 (INSULATED WALL). A. CONTRACTOR MUST PREPARE AND SUBMIT A COMPLETE PIPING SCHEMATIC TO THE LOCAL MANUFACTURER REPRESENTATIVE FOR APPROVAL PRIOR TO BEGINNING INSTALLATION. UPON COMPLETION OF PIPING, THIS CONTRACTOR MUST CALL THE LOCAL REPRESENTATIVE FOR FIELD INSPECTION OF WORK PERFORMED . ALL ITEMS FOUND TO BE INADEQUATE FOR PROPER PERFORMANCE BY MANUFACTURER REPRESENTATIVE MUST BE CORRECTED. THIS INSPECTION IS PERFORMED AT ESD &C EXPENSE. A. METAL DUCTWORK - NO FIBERGLASS DUCT ALLOWED 1. NO DUCTWORK SHALL BE FABRICATED PRIOR TO JOB SITE VISIT AND APPROVAL BY THE GENERAL CONTRACTOR. A SKETCH MUST BE SUBMITTED INDICATING DEVIATIONS FROM DESIGN AND MUST BE APPROVED BY ESD &C'S PROJECT MANAGER PRIOR TO FABRICATION OR INSTALLATION. 2. EXCEPT AS OTHERWISE INDICATED, FABRICATE AND INSTALL RECTANGULAR AND ROUND DUCTWORK WITH GALVANIZED STEEL, IN ACCORDANCE WITH SMACNA "HVAC DUCT CONSTRUCTION STANDARDS" OF THE LATEST EDITION. WHERE OTHER CODES ARE ENFORCED, (1E. UMC, I30CA, ETC.) USE THE MOST STRINGENT CODE FOR DUCT CONSTRUCTION STANDARDS. 3. EXCEPT WHERE OTHERWISE INDICATED, CONSTRUCT DUCT SYSTEMS TO THE FOLLOWING PRESSURE CLASSIFICATIONS: SUPPLY DUCTS: 2" W.G., POSITIVE RETURN AND EXHAUST DUCTS: 2" W.G., NEGATIVE EXCEPT WHERE OTHERWISE INDICATED, USE DUCT SEALANTS OF THE FOLLOWING PRESSURE CLASSIFICATIONS: SUPPLY DUCTS: CLASS B - 3" W.G. RETURN AND EXHAUST DUCTS: CLASS C - 2" W.G. IN ACCORDANCE WITH THESE CONSTRUCTION AND SEALANT PRESSURE CLASSIFICATIONS, MAXIMUM DUCT AIR LEAKAGE WILL NOT EXCEED 5% AS REQUIRED FOR FINAL AIR BALANCE APPROVAL. 4. ROUND DUCTWORK SHALL BE GALVANIZED STEEL WITH SPIRAL LOCKSEAM CONSTRUCTION FOR ALL SIZES 14" DIAMETER AND LARGER. ROUND DUCTWORK SIZES 13" DIAMETER AND SMALLER MAY BE SNAP -LOCK CONSTRUCTION. ALL SNAP -LOCK SEAMS SHALL BE SEALED AS DESCRIBED IN THESE SPECIFICATIONS. ROUND FITTINGS SHALL BE GALVANIZED STEEL WITH SPOT WELDED AND BONDED CONSTRUCTION. 5. ROUND SPIRAL GALVANIZED STEEL DUCTWORK MAY BE USED IN PLACE OF RECTANGULAR DUCTWORK IN HORIZONTAL APPLICATION WHEN ABOVE CEILING CLEARANCES PERMITS AND EQUIVALENT FREE AREA IS MAINTAINED, WITH THE FOLLOWING EXCEPTION; ALL SUPPLY AND RETURN DUCTWORK WITHIN 15 FEET OF THE AIR HANDLER MUST BE RECTANGULAR AND INTERNALLY LINED. ONCE A TRANSITION IN THE DIRECTION OF THE AIRFLOW TO SPIRAL HAS BEEN DONE, DUCT WILL NOT BE ALLOWED TO REVERT TO RECTANGULAR. WHERE ROUND DUCT SUBSTITUTION WILL TAKE PLACE, SUBMIT A SKETCH AND CHART SHOWING EQUIVALENT ROUND CONVERSIONS OF RECTANGULAR DUCTWORK TO ESD &C PROJECT MANAGER'S FOR APPROVAL PRIOR TO FABRICATION OR INSTALLATION. 6. INSTALL FACTORY MANUFACTURED DOUBLE THICKNESS TURNING VANES IN RIGHT ANGLE ELBOWS IN MAIN DUCT PER LATEST EDITION OF SMACNA. 7. INSTALL RIGID ROUND AND RECTANGULAR METAL DUCT WITH SUPPORT SYSTEMS INDICATED IN SMACNA STANDARDS. SUPPORT HORIZONTAL DUCTS WITHIN 2 FEET OF EACH ELBOW AND WITHIN 4 FEET OF EACH BRANCH INTERSECTION USING DOUBLE STRAP HANGERS ON EACH SIDE OF FITTING. SUPPORT VERTICAL DUCTS AT A MAXIMUM INTERVAL OF 16 FEET AND AT EACH FLOOR. NO WOOD SHALL BE USED TO SUPPORT OR BRACE DUCTS. PROVIDE SWAY AND SEISMIC BRACING AS REQUIRED BY STATE AND LOCAL CODES OR BY LANDLORD. 8, WHERE DUCTS PASS THROUGH ROOFS AND FLOORS, PROVIDE AS MINIMUM 1- 1/2 "X1 -1/2" X1/8" STEEL ANGLE FRAMES AT EACH SIDE OF OPENING. THE ANNULAR SPACE BETWEEN DUCT AND ANGLE FRAMES SHALL BE CAULKED WITH SILICONE SEALANT OR FIREPROOFED AS REQUIRED BY ASSEMBLY FIRE RATING. 9. ALL JOINTS AND SEAMS SHALL BE SEALED WITH 2" WIDE, GLASS- FIBER- FABRIC REINFORCED TAPE. JOINTS ALSO SHALL BE RIVETED OR CONNECTED WITH SHEET METAL SCREWS. LIQUID SEALANTS BY UNITED MCGILL CORP., DOW CORNING, MIRACLE ADHESIVES AND SUREBOND INC. WILL BE ACCEPTED IN LIEU OF TAPE. 10. SOFT ELASTOMER BUTYL GASKET WITH ADHESIVE BACKING SHALL BE USED TO SEAL FLANGED JOINTS. 11. DUCT TRANSITIONS SHALL NOT EXCEED 30 DEGREES SLOPE EXCEPT AS SPECIFICALLY NOTED OTHERWISE. 12. PROVIDE ACCESS TO ALL MOTORIZED DAMPERS, FIRE DAMPERS, CONTROLS, AND OTHER ITEMS IN DUCTWORK THAT REQUIRE SERVICE OR INSPECTION. IF THE ACCESS PANEL LOCATION IS EXPOSED TO THE SALES AREA, IT MUST BE APPROVED BY ESD &C'S PROJECT MANAGER PRIOR TO INSTALLATION. IN HARD CEILINGS, LAY -IN SUPPLY AND RETURN AIR DIFFUSERS, GRILLES AND REGISTERS WITH PLASTER FRAMES MAY BE USED AS ACCESS LOCATIONS WHEN WITHIN 3'-O OF DEVICE. 13. ALL DUCTWORK SHALL BE INSTALLED WITH INSIDE CLEAR DIMENSIONS AS NOTED ON DRAWINGS. WHERE DUCTWORK SIZE IS LARGER THAN CONNECTED DEVICE (IE. VAV BOX, DIFFUSER, REGISTER) SMOOTH DUCT TRANSITIONS ARE TO TAKE PLACE JUST PRIOR TO DEVICE CONNECTION. SEE MECHANICAL DRAWINGS FOR DETAIL 1. 2. 3. 4. PRESSURE DUCT WHERE DUCTWORK I ICALLY NOTED AS MEDIUM PRESSURE, IT SHALL BE CONSTRUCTED IN ACCT WITH SMACNA STANDARDS FOR A PRESSURE OF 4 INCHES WATER COLUMN MINIMUM OR GREATER • • RED BY LANDLORD. ALL GAUGES AND REINFORCEMENT MUST MEET WIT WITH THE LANDLORD'S CRITERIA. CONNECTIONS TO THE LANDLORD'S MEDI OTHERWISE REQUIRED BY THE + ' D. FROM METAL DUCTWORK SPECIFICATION SECTION APPLY TO THIS SECTION, WITH THE EXCEPTIO LL MEDIUM ALL OTHE E DUCTWORK MUST BE WRAPPED WITH INSULATION, NOT LINED. TEST EDITIO + CNA STANDARDS FOR MEDIUM PRESSURE DUCT AND SURE DUCTWORK SHALL BE MADE " 0- LOSS" SADDLE TEE TAPS OR AS END OF SECTION 233100 SECTION 233300 AIR DUCT ACCESSORIES A. FLEXIBLE CONNECTIONS 1. FLEXIBLE COLLARS SHALL BE FURNISHED AND INSTALLED IN ALL CONNECTIONS BETWEEN VIBRATING EQUIPMENT (FANS, AIR HANDLERS, ETC.) AND DUCTS OR CASINGS. ALSO, FURNISH AND INSTALL FLEXIBLE CONNECTIONS WHERE DUCTS CROSS BUILDING EXPANSION JOINTS. 2. FLEXIBLE CONNECTIONS SHALL BE CONSTRUCTED OF NEOPRENE - COATED FLAMEPROOF FABRIC. PROVIDE ADEQUATE JOINT FLEXIBILITY TO ALLOW FOR MOVEMENT AND PREVENT THE TRANSMISSION OF VIBRATION. B. FLEXIBLE AIR DUCT 1. FLEXIBLE AIR DUCT SHALL BE 1" INSULATED CLASS 1, UL LISTED AND RATED FOR THE OPERATING PRESSURE OF THE SYSTEM. DUCT CONSTRUCTION MATERIAL (PLASTIC, CLOTH, ALUMINUM) MUST ADHERE TO LOCAL CODES AND LANDLORD'S REQUIREMENTS AND BE INCLUDED AS SUCH IN THE BID. 2. FLEXIBLE AIR DUCT SHALL BE ATTACHED PER DETAILS ON THE DRAWINGS. FLEXIBLE AIR DUCT MAY ONLY BE USED IN VERTICAL APPLICATIONS. 3. FLEXIBLE DUCT SHALL NOT EXTEND OVER 4' -O" IN LENGTH AT ANY ONE LOCATION. C. SUPPLY AIR TAKE -OFF FITTINGS 1. FURNISH AND INSTALL CONICAL, TAPERED OR 45 DEGREE SADDLE TAKEOFFS FROM MAIN DUCTWORK TO ROUND BRANCHES. INSTALLATION SHALL BE PER SMACNA LATEST EDITION. D. DAMPERS 1. WHERE DESIGNATED, FURNISH AND INSTALL MANUAL LOCKING QUADRANT VOLUME CONTROL DAMPERS WITH HANDLE OPERATORS AS SHOWN ON PLANS TO FACILITATE AIR BALANCING. DAMPER SHALL BE DURODYNE MODEL NO: K SERIES QUADRANT OR ESD &C APPROVED EQUAL. 2. OPERATING HANDLES ON ALL DAMPERS SHALL BE TAGGED WITH A MINIMUM 18" LONG ORANGE MARKER TAPE. 3. WHERE ACCESS TO BALANCING DAMPER IS RESTRICTED, A REMOTE DEVICE, MANUALLY OPERATED SHALL BE USED. UNITS SHALL BE ORDERED THREE WEEKS BEFORE INSTALLATION TO ALLOW FOR DELIVERY LEAD TIME. SMOKE DAMPERS 1. FURNISH AND IN HORIZONTAL OR VERTICAL FL 2. FIRE DAMPERS SHALL HAVE THE BLADES OUT OF TH AND INSTALL ACCESS DOORS AS NECESSARY. 3. FURNISH AND INSTALL ALL NECES MING AND SLEEVES FOR DAMPER MOUNTING 4. FIRE SMO END OF SECTION 233300 ARY FIRE DAMPERS WHERE INDICATED OR REQUIRED BY CODES. DAMPERS SH i SIGNED FOR AS REQUIRED. FIRE DAMPERS SHALL BE UL LABELED • T ALL CODE REQUIREMENTS. AM AN ) , DEGREE F FUSIBLE LINK, TYPE B, AS MINIMUM. FURNISH • • 1 1 D CODE REQUIREMENTS. RS SHALL BE FURNISHED AND INSTALLED WITH ELECTRIC POWERED MECHANISM. COORDINATE TOR FOR POWER REQUIREMENTS. Play review approval is subject to errors Emtl orl sslons. Approval of construction documents cis not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and c,p d ons is acknowledged: City of Tukwila U MONO DIVISION riek REVISIONS No changes shall be made to the scope Of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. RECEIVE() CITY OF TUKWILA APR 2 9 2008 PERMIT CENTER TRICAL KtvAtVVtu rVk. CODE COMPLIANCE APPROVED MAY -- 8 708 it C Of Tukwila BUIL INC DIVISION EPARATE PERMIT REQUIRED FOR: 0 Mechanical ./ Electrical I[ umbing LTGas Piping City of Tukwila BUILDING DIVISION JJI 1:" 22 NTS ODM011AOSPE MECHANICAL SPECIFICATIONS SHREMSHOCK INC. 6130 S. St B# R ` ROAD WESTERVI .L_..::` 614 -545 z = �_a U O C e J n Z ©L V, O W SW e O W U wx0er )>< £zocWxz [L F^Udce W Q ° ,,,0 en rm W w E °,e= w n 1-z O F - aW - W O p H . - W z °,_,pF- W W .._ 0 w O m Z - '"'T..2 a u ,-- O r : w w m N ° -, I r y P1 „...„ ck w- o'- a. • O U V = W U w 1-, � 0.Q © W d ( z W�a Q� . „ Z� W m = W O Q_..;z L7 0HN O s ; a mo = 0 a- . 4 �. - - z r 4 3 � ; %! i i re O iL Lj W W 1 N° 2 6 v! w w r I n 0 ' 4 O Li C) 2 O © d = W v1 = ,nw00 ZC7W r U f.JO Z ,W 0rz a= z z mar � �� - O� w ���W g 1 U 4 V, V, [ 1 U w W =arwx 2 Z W-C 0. r t- 4�4fnO 0 CC W I- z w Z I- J Q CO O co mot w# W r co Z a) LIU U W IpW 0 O® I- W W X W N < REVISIONS: + INDICATES NO REVISION TO THIS SHEET dist Z m Bozo,_ 2 wz ▪ Zi Di O © D '- N REQUIRED BY: DATE DATE ISSUED: 04/18/2008 DESIGNED BY: BJD DRAWN BY: BJ D CHECKED BY: JTP MECHANICAL SPECIFICATIONS I f n � !II DRAWING NUMBER: N N 0 CO LO co cO 0 00 Z U Li 0 o < ce W w 0- CD < a CO 0 co Lo r 0 • 0 z o w a_ N r r - n Irl 0 0 z V 0 z -o O 0 co a r♦� co Co 0 -nC) c MATCH LINE v C- m z m z z © en ® a s O I UI . 40 0 0 is 0 • (0 �IJ Q 0 a 0 3 0 0 co z m t (1: cm -‹ CI CI rri: coo 3r rn6 . € 0 lor Iha N C3 str a 151 CA N P O • C \ MALL CONCOURSE (N.I.C.) w (r UI CX 0 N O Isr \ \ r r ; W O cn ° N / 410 .. O O 0 a MI 0 0 zu 0 0 me • CO a N a a -1 Co 0 0 0 z / l \ J UI CA N 0 U) o' G) C) MATCH LINE a 0 z .- 0 z C) co xi 0 of z xi m > m > cif) —1 5 m IT1 v, C C_ 0 CO m G' G m EA 0 C)) PROJECT INFORMATION: EXPRESS WESTFIELD SOUTHCENTER SPACE #332 1 070 SOUTHCENTER MALL SEATTLE, WA 98188 SCOPE: DESIGN TYPE: ESD&C PROJECT #: PACKAGE: HAYWOOD GENERATION: 00005818 A/E PROJECT #: 0000581 PKG 2 081 5a 08098 PROHIEITION ON REUSE: THESE DRAWINGS AND SPECIFICATIONS WERE PREPARED FOR USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH THEIR ISSUE DATE. THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. REUSE OF THESE DRAWINGS AND SPECIFICATIONS, OR ANY REPRODUCTION THEREOF, ON ANOTHER PROJECT IS PROHIBITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIZED IN WRITING BY EXPRESS STORE PLANNING, INC., D /B /A EXPRESS STORE DESIGN AND CONSTRUCTION ( "ESDC "). THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF ESDC AND SHALL NOT EE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER PROJECT EXCEPT BY WRITTEN AGREEMENT WITH ESDC. ND REPRODUCTION OF THESE DRAWINGS AND SPECIFICATIONS SHALL EE MADE WITHOUT THE WRITTEN AUTHORIZATION OF THE ESDC. ALL ORIGINALS OR REPRODUCTIONS OF THESE DRAWINGS AND SPECIFICATIONS MUST RE RETURNED TO LSDC UPON COMPLETION OF THEIR INTENDED USE, UNLESS OTHERWISE AGREED BY THE ESDC. COPYRIGHT NOTICE: THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS A "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED DECEMBER 1950; KNOWN AS THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1950. THE PROTECTION INCLUDES, WITHOUT IMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION OF SPACES, AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CESSATION OF CONSTRUCTION, BUILDING SEIZURE, AND /OR MONETARY LIABILITY. EXPRESS STORE PLANNING, INC. db /a. STORE DESIGN & CONSTRUCTION D) J O : Cr) &r I - Q m C m / u < . 0 0 c) EADTVOCAO Dr. E0.11143411X, P, PROJECT INFORMATION: EXPRESS WESTFIELD SOUTHCENTER SPACE #332 1070 SOUTHCENTER MALL SEATTLE, WA 98188 SCOPE: I PACKAGE: DESIGN TYPE: HAYWOOD GENERATION: ESD &C PROJECT #: 00005818 A/E PROJECT #: 0000581 PKG 2 08150 08098 PROHIBITION ON REUSE: THESE DRAWINGS ANC SPECIFICATIONS WERE PREPARED FOR USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH THEIR ISSUE DATE. THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. REUSE OF THESE DRAWINGS AND SPECIFICATIONS, OR ANY REPRODUCTION THEREOF, ON ANOTHER PROJECT IS PROHIBITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIZED IN WRITING BY EXPRESS STORE PLANNING, INC., D /B /A EXPRESS STORE DESIGN AND CONSTRUCTION ( "ESDC "). THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF ESDC AND SHALL NOT DE DISPLAYED IN ANY MANNER CR USED ON ANY OTHER PROJECT EXCEPT BY WRITTEN AGREEMENT WITH ESDC. ND REPRODUCTION OF THESE DRAWINGS AND SPECIFICATIONS SHALL RE MADE WITHOUT THE WRITTEN AUTHORIZATION OF THE ESDC. ALL ORIGINALS OR REPRODUCTIONS OF THESE DRAWINGS AND SPECIFICATIONS MUST RE RETURNED TO LSDC UPON COMPLETION OF THEIR INTENDED USE, UNLESS OTHERWISE AGREED BY THE ESDC. COPYRIGHT NOTICE: THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN I "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED DECEMBER 1990; KNOWN AS THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION INCLUDES, WITHOUT IMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION OF SPACES, AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CESSATION OF CONSTRUCTION, BUILDING SEIZURE, AND /OR MONETARY LIABIUTY. MATCH LINE EXPRESS STORE PLANNING, INC. d /b/a STORE DESIGN & CONSTRUCTION NATIONAL ACCOUNTS HVAC SUPPLIER GENERAL NOTES MARK HVAC EQUIPMENT NOTED HAS BEEN PREPURCHASED BY EXPRESS STORE DESIGN & CONSTRUCTION. WITHIN THE FIRST WEEK OF CONSTRUCTION, THE GENERAL CONTRACTOR OR THEIR MECHANICAL SUBCONTRACTOR SHALL NOTIFY SUPPLIER VIA EMAIL. THE EMAIL SHALL STATE THE PHONE NUMBER, EMAIL ADDRESS AND DELIVERY ADDRESS OF THE CONTACT PERSON RESPONSIBLE FOR SCHEDULING AND RECEIVING THE HVAC EQUIPMENT AND ACCESSORIES. EQUIPMENT AND ACCESSORIES ARE TO BE SHIPPED BY ANY SPECIAL SHIPPING INSTRUCTIONS REQUIRED OR REQUESTED. ALLOW A MINIMUM OF TWO WEEKS AFTER CONSTRUCTION STARTS FOR DELIVERY UNLESS SPECIAL ARRANGEMENTS ARE MADE PRIOR TO THE START OF CONSTRUCTION. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY ADDITIONAL SHIPPING COST INCURRED IF DELIVERY IS REQUIRED PRIOR TO THE STANDARD TWO WEEKS SCHEDULED. IF THIS INFORMATION IS NOT SENT TO NATIONAL ACCOUNT SUPPLIER, THEN THE EQUIPMENT AND ACCESSORIES WILL BE SHIPPED IN ACCORDANCE WITH THE PURCHASE ORDER DATE AND INSTRUCTIONS ISSUED BY ESD &C AND THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR UNLOADING AND STORAGE OF EQUIPMENT UNTIL SUCH TIME AS REQUIRED FOR INSTALLATION ON PROJECT. IF OWNER'S REPRESENTATIVE IS PERFORMING START UP, THEN GC AND /OR MECHANICAL CONTRACTOR MUST COORDINATE WITH MANUFACTURER REP. 2 WEEKS PRIOR TO CONSTRUCTION END DATE. CONTACT INFORMATION SD -3 JIM HOOVLER JODY SOWERS VICKI TAYNER TRANE NATIONAL ACCOUNTS REPRESENTATIVE TRANE TECHNICAL SUPPORT, PRIMARY HVAC COMMISSIONING EMAIL JEHOOVLEROTRANE,COM EMAIL JSOWERSOTRANE.COM EMAIL VICKI,TAYNEROTRANE,COM PHONE NO: 866.415,2499 PHONE NO: 866.415.2499 PHONE NO: 866.415.2499 SCOTT CRABTREE DAN SCHONDELMAYER TRANE NATIONAL ACCOUNTS REPRESENTATIVE TRANE SHIPPING EMAIL: SECRABTREEOTRANE.COM (OR TECHNICAL SUPPORT, SECONDARY) PHONE NO: 866.415.2499 EMAIL: DCSCHONELMAYERBTRANE.COM PHONE NO: 866.415.2499 GRILLE, REGISTER, AND DIFFUSER SCHEDULE MARK SD -1 SD -2 SD -3 SD -4 MANUFACTURER TITUS TITUS TITUS TITUS MODEL _ OMNI OMNI TMSA 300 -RL NECK SIZE (L "XW ") SEE PLAN SEE PLAN SEE PLAN 10 "x8" FRAME SIZE (L "XW") 24 "x24" 24 "x24" 12 "x12" 12 "x10" FRAME TYPE LAY -IN LAY -IN LAY -IN DUCT MOUNTED FINISH TITUS /27 TITUS #27 <30 TITUS ,' 27 <30 TITUS /27 <30 NOISE CRITERIA LEVEL <30 ACCESSORIES 2,6 2 2,6 1 NOTES 1,3 1,3 1,3 INPUT (KW) 50 170.75 MARK RG -1 RG -2 RG -3 STAGES MANUFACTURER TITUS TITUS TITUS ELECTRICAL MODEL 50F 355 -RL 355 -RL NECK SIZE (L "XW ") 22 "x22" 22 "x10" 1O "x10" FRAME SIZE (L "XW") 24 "x24" 24 "x12" 12 "x12" FRAME TYPE LAY -IN LAY -IN LAY -IN FINISH TITUS 127 TITUS #27 TITUS #27 NOISE CRITERIA LEVEL < 30 <30 <30 ACCESSORIES 2,6 NOTES -- 2,3 2,3 MARK (ACCU -#) 1 ACCESSORIES: 1. OBD- OPPOSED BLADE DAMPER 2. LQD- LOCKING QUADRANT VOLUME DAMPER (PROVIDED BY MECHANICAL CONTRACTOR). SEE MECHANICAL SPECIFICATIONS SECTION 233300.D.1, SHEET M01.1 3, CFD - RUSKIN MODEL CFD OR CFDR FIRE DAMPER WITH VOLUME CONTROL 4. YRD-YOUNG'S REGULATOR REMOTE DAMPER WITH CABLE CONTROL SYSTEM (MODEL 5020 -CC) 5. LSP- INSULATED LINEAR SLOT PLENUM 6. TRM -RAPID MOUNT FRAME FOR GYPSUM CEILINGS NOTES: 1, 4 -WAY DIFFUSER (UNLESS 2 -WAY OR 3 -WAY AS INDICATED ON PLAN). 2. INSTALL BLADES FACING THE BACK OF STORE, CABINET, OR WALL. 3. GC TO FIELD PAINT DIFFUSERS TO MATCH CEILING OR WALL WITH ENAMEL FINISH. MARK (AHU -#) 1 TRANE PACKAGE NUMBER LPC MODEL LPCA14F AIR FLOW (CFM) 8000 OA FLOW (CFM) 2265 EXT. SP. (IN W.C.) 0.5 DX COOLING COIL - EAT 'FOB WB) - 82.0 64.4 TOTAL (MBH) 193.79 SENSIBLE (MBH) 193,48 -- ELECTRIC HEAT INPUT (KW) 50 170.75 OUTPUT (MBH) STAGES 2 ELECTRICAL VOLTS /0 /HZ 460 3 60 MOTOR HP 7 1/2 MCA (AMPS) 70,7 FLA (AMPS) 56.56 APPROX. WEIGHT (LBS) 1011 ACCESSORIES 1 -8 NOTES 1 ACCESSORIES ( "S" INDICATES STANDARD; "O" INDICATES OPTIONAL): 1. S- COMBINATION FAN CONTACTOR /DISCONNECT SWITCH (IN HEATER CONTROL CABINET WHERE APPLICABLE). 2. S- FACTORY PROVIDED 1" MATT INSULATION. 1 S- FACTORY FURNISHED MIXING BOX WITH ACTUATOR AND 0 -10 VOLT ADAPTER. 4. S- FACTORY FURNISHED VIBRATION ISOLATORS. 5. S- FACTORY FURNISHED FAN PROOVING SWITCH. 6. S- FACTORY PROVIDED CONDENSATE PAN OVERFLOW SWITCH. 7. S- FACTORY FURNISHED THERMAL EXPANSION VALVE. 8. S -FOUR ROW DX COIL 9. 0 -TWO ROW HOT WATER COIL 10. 0- FACTORY PROVIDED ELECTRIC HEATER WITH SINGLE POINT CONNECTION (REHEAT POSITION). NOTES: 1. REFER TO CONTROL WIRING SCHEMATICS FOR ANY FIELD INSTALLED CONTROL DEVICES NOT FACTORY INSTALLED. AIR COOLED CONDENSING UNIT SCHEDULE MARK (ACCU -#) 1 TRANE PACKAGE NUMBER TTA MODEL I SEER (EER) TTA240 / 9.7 AMBIENT OA TEMP (DEG F DB) 85 TOTAL CAPACITY (MBH) 237.66 PHYSICAL DATA NO. OF FANS 2 NO. OF COMP. 2 ELECTRICAL VOLTS/0/1-1Z 460/3/60 MCA (AMPS) 42.5 MOCP (AMPS) 50.00 APPROX. WEIGHT (LBS) 900 ACCESSORIES 1 -5 NOTES ACCESSORIES ("5" INDICATES STANDARD; "O" INDICATES OPTIONAL): 1. S- FACTORY FURNISHED TRANSFORMER FOR FIELD APPLIED CONTROLS. 2. S- PROVIDE DUAL COMPRESSORS WITH SEPARATE CIRCUITS FOR ALL UNITS 10 TONS & ABOVE. 3. S- FACTORY PROVIDED 5 MINUTE DELAY OFF TIMING ON COMPRESSOR RESTART. 4. S- FACTORY FURNISHED LOW AMBIENT CONTROL, 5. S- FACTORY PROVIDED HIGH AND LOW PRESSURE SWITCHES. NOTES: EXHAUST AND VENTILATION FAN SCHEDULE MARK (EF-4t) l 1 MANUFACTURER LOREN COOK MODEL GEMINI 122 TYPE CEILING MOUNTED DRIVE TYPE DIRECT PERFORMANCE AIR FLOW (CFM) 75 EXT. STATIC (IN W.C.) 0.375 FAN SPEED (RPM) 1500 ELECTRICAL VOLTS /0/HZ - 120/1 /60 FAN MOTOR WATTS 70 APPROX. WEIGHT (LBS) 15 SERVES RESTROOMS ACCESSORIES 1 NOTES 1 ACCESSORIES ("8" INDICATES STANDARD; "0" INDICATES OPTIONAL): GENERAL NOTES ALL NOTES INCLUDED HEREIN ARE MADE PART OF EACH AND ALL MECHANICAL, ELECTRICAL AND PLUMBING SECTIONS OF WORK. 1. REFER TO LANDLORD'S SPECIFICATIONS AND TENANT DESIGN CRITERIA FOR NECESSARY INFORMATION AND COORDINATION WITH OTHER TRADES. 2. THE ABBREVIATION ESD &C WHEREVER IT APPEARS IN THE DRAWINGS, SHALL REFER TO "EXPRESS STORE DESIGN AND CONSTRUCTION ", ANY REFERENCE TO TENANT, BRAND SPECIFIC (EXPRESS, ETC.) OR FURNISHED BY ANY OF THE ABOVE REFERS TO ESD &C. 3. ANY DISCREPANCY BETWEEN ESD &C DRAWINGS AND TENANT CRITERIA, ESD &C DRAWINGS SHALL TAKE PRECEDENCE. 4. THE DRAWINGS ARE ESSENTIALLY DIAGRAMMATIC TO THE EXTENT THAT ALL INSTALLED ITEMS AND LOCATIONS ARE NOT EXACTLY PLACED AND ARE NOT TO BE SCALED. 5. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR ALL RELATED PERMITS AND INSPECTION FEES. 6. BEFORE COMMENCING ANY WORK, CONTRACTORS SHALL REVIEW THE LATEST NATIONAL, STATE AND LOCAL CODE REQUIREMENTS INCLUDING LANDLORD CRITERIA AND PERFORM THE WORK IN STRICT ACCORDANCE WITH THESE. IN CASE OF CONFLICT THE STRICTER REQUIREMENTS WILL PREVAIL. 7. NO ADDITIONAL COMPENSATION SHALL BE MADE FOR ANY CHANGE ORDERS DUE TO CONTRACTOR'S FAILURE TO VISIT THE JOBSITE AND /OR PREDETERMINE ALL EXISTING CONDITIONS BEFORE SUBMITTING HIS BID. A. CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING CONDITIONS PRIOR TO SUBMITTING A BID. FOR THE PURPOSE OF SURVEYING EXISTING CONDITIONS, WHICH MAY AFFECT THE WORK TO BE DONE UNDER THIS SECTION, ANY DISCREPANCIES SHALL BE IMMEDIATELY REPORTED TO THE GENERAL CONTRACTOR, ESD &C OR THE LANDLORD'S FIELD REPRESENTATIVE FOR CLARIFICATION. B. AFTER BID, ANY QUESTIONS RELATING TO SPECIFIC M, E, OR P ISSUES ARE TO BE DIRECTED AS RFI'S THROUGH THE ESD &C PROJECT MANAGER. C. SHOULD THE SPACE HAVE BEEN INACCESSIBLE FOR INSPECTION CONTRACTOR MUST INDICATE SO ON HIS BID. 8. THE GENERAL CONTRACTOR'S FIRE SPRINKLER SUBCONTRACTOR SHALL DESIGN AND INSTALL FIRE SPRINKLER SYSTEM CONFORMING TO LANDLORD'S CRITERIA, TENANT'S REQUIREMENTS AND PER LOCAL CODES AND NFPA STANDARDS. 9. THE CONTRACTOR, WITHIN FIFTEEN (15) DAYS OF THE AWARD OF THE CONTRACT, SHALL SUBMIT TO THE OWNER, SIX (6) COPIES OF A COMPLETE LIST OF MATERIALS AND EQUIPMENT PROPOSED FOR THE JOB INCLUDING ALL DATA, PART NUMBERS, RATING CAPACITY, SIZE, DIMENSIONS, ELECTRICAL DATA, GRADE, MANUFACTURER, AND ANY OTHER DESCRIPTIVE DATA FOR ALL EQUIPMENT OR SYSTEMS THAT DEVIATE FROM SPECIFIED ITEMS. ANY DELAYS OR COSTS DUE TO THESE DEVIATIONS, WILL BE THE RESPONSIBILITY OF THE CONTRACTOR. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR THE DISPOSAL OF ALL UNUSED OR ABANDONED MATERIALS AND EQUIPMENT, AND ITS REMOVAL OFF THE LANDLORD'S PREMISES. 11. OWNER RESERVES THE RIGHT TO HAVE CONSTRUCTION REVIEWED BY AN OUTSIDE CONSULTANT PRIOR TO ACCEPTANCE OF THE PROJECT. 12. EACH CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP RELATED TO HIS WORK FOR A MINIMUM PERIOD OF ONE YEAR FROM THE DATE WHICH THE OWNER ACCEPTS THE PROJECT. THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER OR TENANT SHALL CORRECT ANY DEFECTS IN MATERIALS OR WORKMANSHIP DURING THIS GUARANTEE PERIOD. 13. EACH CONTRACTOR SHALL BE RESPONSIBLE AND ENSURE A CLEAN INSTALLATION ESPECIALLY IN EXPOSED CEILING AREAS. THE FINAL APPROVAL OF THIS WORK WILL BE ISSUED BY ESD &C PROJECT MANAGER. 14. PROVIDE THREE SETS OF "AS- BUILT" DRAWINGS AND TWO BOUND SETS OF ALL OPERATIONS MANUALS, DIAGRAMS, SERVICE CONTRACTS AND GUARANTEES TO ESD &C PRECEDENT TO FINAL PAYMENT. A REPORT PREPARED BY AN INDEPENDENT AIR BALANCE CONTRACTOR, HIRED BY GC, MUST BE INCLUDED IN THE CLOSE -OUT PACKAGE. HVAC GENERAL NOTES 1. THESE PLANS MAY BE USED FOR CONSTRUCTION ONLY AFTER APPROVAL IS OBTAINED FROM THE BUILDING DEPARTMENT MECHANICAL PLAN CHECK DIVISION AND THAT DIVISION'S STAMPED APPROVAL AND AUTHORIZED SIGNATURE APPEAR ON THE PLANS. 2. COORDINATE ALL WORK WITH ALL TRADES INCLUDED BUT NOT EXPRESS TO ELECTRICAL, PLUMBING, FIRE PROTECTION AND STRUCTURAL CONTRACTORS. INSTALL ALL WORK TO CLEAR NEW AND EXISTING ARCHITECTURAL AND STRUCTURAL MEMBERS. NO ITEM SUCH AS PIPE, DUCT, ETC. IS TO COME IN CONTACT WITH ANY EQUIPMENT. 3. REFER TO ARCHITECTURAL DRAWINGS FOR DEMOLITION WORK. 4. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT FIXTURE LOCATION. 5. CONTRACTOR SHALL PROVIDE CUT SHEETS TO ESQ &C FOR ALL EQUIPMENT AND DEVICES FURNISHED BY THE CONTRACTOR THAT DEVIATE FROM SPECIFIED ITEM FOR REVIEW AND APPROVAL PRIOR TO THE PURCHASE OF ANY SUCH EQUIPMENT OR DEVICES. 6. HVAC CONTRACTOR IS RESPONSIBLE TO INQUIRE WITH THE LANDLORD'S REPRESENTATIVE ON ANY SMOKE EVACUATION SYSTEM IN USE AT THE MALL AT THE TIME OF THE BID. IF THE SAID SYSTEM IS NOT ADEQUATELY DESCRIBED ON THE DRAWINGS, THE MECHANICAL CONTRACTOR IS RESPONSIBLE TO INFORM THE GENERAL CONTRACTOR AND INCLUDE THE COST AS A SEPARATE LINE ITEM IN THE BID. NO ADDITIONAL MONEYS SHALL BE AWARDED FOR TIE -IN REQUIREMENTS TO A LANDLORD'S SMOKE EVACUATION SYSTEM THAT IS IN EXISTENCE AT THE TIME OF THE BID, WITHOUT HAVING IDENTIFIED A SEPARATE LINE ITEM FOR THE SMOKE EVACUATION SYSTEM AT THE TIME OF THE BID. 7. ACCESS TO ALL COMPONENTS AND EQUIPMENT MUST BE PROVIDED TO MEET CODE AND SERVICE /MAINTENANCE EASE. 8, PRIOR TO STARTUP OF HVAC EQUIPMENT, MECHANICAL CONTRACTOR WILL CONFIRM WITH ONE OF THE LISTED HVAC MANUFACTURER REPRESENTATIVES THAT CORRECT POWER FOR EQUIPMENT HAS BEEN PROVIDED TO ESD &C PROVIDED HVAC UNITS AND HAS BEEN TURNED ON FOR A MINIMUM OF 24 HOURS. ESD &C RESERVES THE RIGHT TO CHECK CONSTRUCTION COMPLIANCE WITH PLANS AND SPECIFICATIONS. SHOULD THE OWNER FIND CORRECTIVE WORK TO BE NECESSARY, HE WILL NOTIFY CONTRACTOR OF SUCH WORK IN WRITING AND EXPECT COMPLIANCE PERFORMED WITH DUE DILIGENCE. IF ANY CORRECTIVE WORK IS DEEMED TO BE NECESSARY, THE COST OF REINSPECTIONS WILL BE BORNE BY THE CONTRACTOR, THE MECHANICAL CONTRACTOR WILL THEN ENSURE THAT THE EQUIPMENT IS POWERED FOR A MINIMUM OF 24 HRS BEFORE START -UP. 9. IF WORK IS REQUIRED BY ESD &C IN ORDER TO IMPROVE, CHANGE OR CORRECT AIR CONDITIONING OPERATIONAL CONDITIONS DUE TO: PART MALFUNCTION, WARRANTY OR OTHER INABILITY TO PROVIDE THE COMFORT CONDITIONS REQUIRED BY THE STORE, CONTRACTOR SHALL BE DIRECTED BY ESD &C TO ADDRESS THIS WORK IN A TIMELY MANNER. IF IT BECOMES EVIDENT THAT THE CONTRACTOR CANNOT ACCOMPLISH THE TASK, THEN AFTER 72 HOURS OF WRITTEN NOTICE THE OWNER MAY, AT HIS DISCRETION, TAKE OVER SUCH WORK AND BACK CHARGE THE CONTRACTOR FOR ANY CORRECTIVE WORK THAT WAS REQUIRED DUE TO LACK OF PERFORMANCE, WORKMANSHIP AND /OR ADHERENCE TO PLANS AND SPECIFICATIONS. 10. UPON COMPLETION OF THE WORK, CONTRACTOR SHALL VERIFY THE PROPER WORKING ORDER OF THE SYSTEM(S) AND MAKE ANY ADJUSTMENTS AS REQUIRED. 11. PROVIDE FILTER CHANGES THROUGHOUT CONSTRUCTION AS REQUIRED FOR ALL HVAC EQUIPMENT. PROVIDE FILTER CHANGES AT LEAST TWICE MONTHLY ONCE STARTED, PRIOR TO TEST AND BALANCE, AND LASTLY, PRIOR TO MERCHANDISING. ANY EQUIPMENT OR DUCTWORK THAT BECOMES SOILED DUE TO A LACK OF FILTER CHANGES, AS DETERMINED SOLELY BY THE ESQ &C PROJECT MANAGER, SHALL BE CORRECTED ON BEHALF OF THE CONTRACTOR AND CHANGES BILLED TO THE CONTRACTOR. 12. NOTES TO EQUIPMENT SCHEDULES USE THE WORDS "FURNISH" AND "PROVIDETM. WHERE THE WORD "FURNISH" IS USED, SOME FIELD INSTALLATION IS REQUIRED BY THE CONTRACTOR. WHERE THE WORD "PROVIDE" IS USED, NO FIELD INSTALLATION IS REQUIRED AS THE DEVICES OR ACCESSORIES ARE FURNISHED AND INSTALLED BY THE MANUFACTURER AS PART OF THE EQUIPMENT WHEN SHIPPED. 13. UNLESS OTHERWISE SPECIFIED, CONTRACTOR SHALL PROVIDE ALL EQUIPMENT, MATERIAL, LABOR AND SUPERVISION NECESSARY TO COMPLETE THE HEATING, VENTILATING AND AIR CONDITIONING WORK IN ACCORDANCE WITH THE SPECIFICATIONS AND STANDARDS AS OUTLINED HEREIN. SEE RESPONSIBILITY SCHEDULE ON SHEET M04.1. 14. MECHANICAL CONTRACTOR SHALL FIELD MEASURE EXISTING ROOF CURB(S) FOR CURB ADAPTER(S), WHERE APPLICABLE, AND SHALL SUPPLY DIMENSIONS TO ESD &C HVAC SUPPLIER PRIOR TO START OF CONSTRUCTION. 15. ALL HEATING VENTILATING AND AIR CONDITIONING EQUIPMENT SHALL BE CLEARLY IDENTIFIED WITH TENANT'S NAME, SPACE NUMBER AND UNIT DESIGNATION AND SHALL BE STENCILED IN 4" HIGH BLACK LETTERS. 16. FURNISH AND INSTALL ALL NEW DUCTWORK INCLUDING INSTALLATION OF OWNER SUPPLIED PLENUM BOOTS, SUPPLY AIR DIFFUSERS, AND RETURN AIR GRILLES. (SEE AIR DEVICE SCHEDULE ON THIS SHEET). A. ALL MATERIAL SHALL BE NEW AND OF COMMERCIAL GRADE AND BEAR UNDERWRITER'S LABORATORY AND UNION LABELS WHERE SUCH LABELING APPLIES. B. ALL PLENUMS SHALL BE FABRICATED FROM GALVANIZED SHEET METAL OF THE APPROPRIATE GAUGE AND BE INSULATED WITH A MINIMUM OF 1" THICK, 0.75 LB /CU.FT. DENSITY FIBERGLASS INSULATION WITH ALUMINUM FOIL BACKED VAPOR BARRIER. C. WHERE DESIGNATED, BRANCHES FROM MAIN LOW VELOCITY TRUNK DUCTWORK SHALL BE FURNISHED WITH SPLITTERS, DAMPERS OR SIMILAR BALANCING DEVICES IN ACCORDANCE WITH THE STANDARDS OF SMACNA. D. ALL DUCTS FOR FINAL CONNECTION TO DIFFUSERS SHALL BE CLASS 1. U.L, LISTED (51 181) FLEXIBLE AIR DUCT NOT TO EXCEED 4' -0" IN LENGTH (THERMAFLEX, GLASFLEX, OR APPROVED EQUAL). E. SUPPLY AND RETURN DUCTWORK SHALL BE LINED AND WITH CODE COMPLYING BLANKET INSULATION. ACOUSTICAL LINER MAY BE PROVIDED. ALL MATERIALS SHALL COMPLY WITH N.F.P.A. 90A AND 90B. SEE SPECIFICATIONS ON SHEET M01.1. F. HANGER WIRES, DUCT STRAPS, FASTENING DEVICES, ETC. SHALL BE FASTENED TO THE STEEL JOISTS AND /OR BEAMS ABOVE. DO NOT ATTACH ANY SUCH ITEMS DIRECTLY TO FLOOR SLABS, PIPING, OTHER DUCTWORK, ELECTRICAL CONDUITS OR THE ROOF DECK ABOVE. G. ADDITIONAL FIRE DAMPERS SHOULD BE INSTALLED AS REQUIRED BY ANY APPLICABLE CODES AND /OR JURISDICTIONAL AUTHORITIES. 16. SEAL AROUND PIPES AND DUCTS PENETRATING FIRE SEPARATIONS WITH LISTED AND APPROVED FIRE SEAL MATERIAL. ONLY LISTED AND APPROVED SEALANTS AND METHODS FOR THE SPECIFIC USE WILL BE PERMITTED. 17. MECHANICAL CONTRACTOR SHALL INSTALL TEMPERATURE SENSORS AND AS SHOWN ON THE PLAN (VERIFY LOCAL CODES. IF PLAN LOCATION IS NOT ACCEPTABLE, IMMEDIATELY CONTACT ESD &C PROJECT MANAGER FOR DIRECTION.) 18. UPON COMPLETION OF THE WORK, THE CONTRACTOR SHALL FULLY PRESSURE CHECK AND CHARGE ALL REFRIGERANT SYSTEMS (IF REQUIRED). 19. THE CONTRACTOR SHALL ENGAGE THE SERVICES OF AN INDEPENDENT, AIR /WATER BALANCING COMPANY THAT IS A NEBB CERTIFIED CONTRACTOR OR HAS AN AABC CERTIFIED TEST & BALANCE ENGINEER. THIS COMPANY SHALL PERFORM THE BALANCING OF AIR /WATER SYSTEM(S) AND MAKE ANY REQUIRED ADJUSTMENTS TO ENSURE PROPER WORKING ORDER. UPON COMPLETION, THE BALANCING COMPANY SHALL PROVIDE A COMPLETE SYSTEM REPORT. INCLUDED AS A COVER TO THIS REPORT SHALL BE A COMPLETED EXPRESS BRANDS HVAC BALANCE CERTIFICATION FORM. HVAC EQUIPMENT COMMISSIONING DETAILED HVAC COMMISSIONING INFORMATION IS INCLUDED IN THE ESD &C SITE MANUAL PROVIDED TO THE CONTRACTOR AT THE START OF THE PROJECT. MANUFACTURER WILL CONTACT THE CONTRACTOR EARLY IN THE PROJECT TO SET PRELIMINARY DATES FOR HVAC INSPECTION, COMMISSIONING AND HVAC CONTROLS COMMISSIONING. PRIOR TO HVAC INSPECTION / COMMISSIONING (TO BE COMPLETED BY MECHANICAL SUBCONTRACTOR) 1. CONNECT AND BLEED CONDENSATE, DUCTWORK, NATURAL GAS, CHILLED WATER PIPING, AND /OR CONDENSER WATER PIPING. 2. CHARGE HVAC SYSTEMS WITH REFRIGERANT FOLLOWING MANUFACTURERS' GUIDELINES AND INSTRUCTIONS. COLD WEATHER CONDITIONS REQUIRE SPECIFIC PROCESSES, CONTACT MANUFACTURER FOR TECHNICAL SUPPORT, 3. CONNECT POWER TO THE HVAC EQUIPMENT FOR A MINIMUM OF 24 HOURS. NOTE: IN COLD WEATHER SITUATIONS, DO NOT OPERATE THE UNITS PRIOR TO COMMISSIONING! HVAC EQUIPMENT SHOULD BE STARTED UP EARLY IN THE PROJECT. COORDINATE EARLY START UP OF EQUIPMENT WITH MANUFACTURER. NOTE: THE GC MAY BE BACK CHARGED FOR ADDITIONAL AC SITE VISITS BEYOND THE FIRST THREE (3) NECESSARY TO DOCUMENT THE RESOLUTION OF THE HVAC PUNCHLIST ITEMS. HVAC COMMISSIONING PROCESS VISIT 1: HVAC EQUIPMENT START UP 1. CONTRACTOR SHALL HAVE THE MECHANICAL AND ELECTRICAL SUBCONTRACTOR ON SITE DURING THE HVAC INSPECTION AND COMMISSIONING. BUDGET 5 HOURS FOR THE HVAC INSPECTION AND COMMISSIONING. (NOTE: THESE HOURS ARE TO BE USED FOR THE COMPLETION OF THE COMMISSIONING PROCESS ONLY. ADDITIONAL HOURS WILL NOT BE APPROVED FOR WORK THAT WAS IN SCOPE AND NOT COMPLETED PRIOR TO THE COMMISSIONING PROCESS.) 2. CONTRACTOR TO COMPLETE AND EMAIL, OR FAX, THE HVAC EQUIPMENT START UP SURVEY TO MANUFACTURER PRIOR TO THE HVAC STARTUP. 3. MANUFACTURER COORDINATES THE HVAC EQUIPMENT COMMISSIONING. CONTRACTOR IS RESPONSIBLE FOR COMMUNICATING SCHEDULE DATE CHANGES TO MANUFACTURER AND SUBCONTRACTORS. 4. PROVIDED THERE ARE NO HVAC INSTALLATION ISSUES. SYSTEMS SHALL BE STARTED FOR TEMPORARY OPERATION ON LOCAL CONTROL. 5. IF THERE ARE HVAC INSTALLATION PUNCHLIST ITEMS, THE GC MUST CORRECT THEM AND RESCHEDULE COMMISSIONING WITH MANUFACTURER. VISIT 2: HVAC CONTROLS COMMISSIONING THE CONTROLS COMMISSIONING IS PERFORMED BY THE MANUFACTURER IN CONJUNCTION WITH THE GENERAL CONTRACTOR AND THE MECHANICAL AND ELECTRICAL SUBCONTRACTORS. ALLOW FOR 4 HOURS TO COMPLETE T THE CONTROLS COMMISSIONING. (NOTE: THESE HOURS ARE TO BE USED FOR THE COMPLETION OF THE COMMISSIONING PROCESS ONLY. ADDITIONAL HOURS WILL NOT BE APPROVED FOR WORK THAT WAS IN SCOPE AND NOT COMPLETED PRIOR TO THE COMMISSIONING PROCESS.) FOLLOW THE CONSTRUCTION DRAWINGS AND MANUFACTURER'S DETAILS AND DRAWINGS DURING THE INSTALLATION OF THE HVAC CONTROL EQUIPMENT. 1. CONTRACTOR TO COMPLETE AND EMAIL, OR FAX, THE CONTROLS COMMISSIONING SURVEY TO MANUFACTURER PRIOR TO THE CONTROL COMMISSIONING. 2. CONNECT THE HVAC CONTROLS TO AN OPERATIONAL ANALOG PHONE LINE OR ETHERNET CONNECTION TO ALLOW COMMUNICATION. IF NECESSARY, UTILIZE SITE FAX LINE TO CONNECT TO THE CONTROLS MODEM IN THE IFS PANEL. 3. CONTACT MANUFACTURER AT THE SCHEDULED TIME FOR THE CONTROLS COMMISSIONING. 4. PROVIDED THERE ARE NO OPEN ISSUES, VISIT 2 IS COMPLETE. IN THE EVENT THERE ARE OPEN ITEMS, THE GC MUST CORRECT THEM AND RESCHEDULE THE CONTROLS COMMISSIONING. VISIT 3: FINAL HVAC INSPECTION THIS VISIT IS TO DO A FINAL INSPECTION OF THE HVAC EQUIPMENT AND CONTROL INSTALLATION. THIS VISIT MUST TAKE PLACE PRIOR TO CONSTRUCTION COMPLETION. THE FOLLOWING ITEMS MUST BE COMPLETED PRIOR TO THE INSPECTION: 1. HVAC SYSTEM INSTALLATION IS COMPLETE - NO OPEN PUNCHLIST ITEMS EXCEPT FOR POSSIBLY THE PERMANENT PHONE LINE. 2. AIR BALANCE IS COMPLETE. NOTE: AIR BALANCE IS IN THE CONTRACTOR'S SCOPE OF WORK. THE GC MUST COMPLETE TRANE'S SITE VISIT #3 SURVEY PRIOR TO THE VISIT BEING SCHEDULED. THE CONTRACTOR IS RESPONSIBLE FOR HAVING THE MECHANICAL SUBCONTRACTOR AND THE ELECTRICAL SUBCONTRACTOR ON SITE DURING THE FINAL INSPECTION. BUDGET 4 HOURS FOR THE FINAL INSPECTION. 1. THE CONTRACTOR IS RESPONSIBLE FOR COMMUNICATING SCHEDULE DATE CHANGES FOR THE FINAL INSPECTION 2. FILTERS ARE TO BE REPLACED DURING THIS VISIT. FILTERS ARE TO BE PROVIDED BY THE CONTRACTOR AND SHALL BE ON SITE WHEN THE TRANE TECHNICIAN ARRIVES. 3. WHEN COMPLETE AND ALL OPEN CONTRACTOR HVAC ISSUES ARE RESOLVED A CONTROL NUMBER IS ISSUED BY THE MANUFACTURER. IT IS RECORDED INSIDE THE CONTROL PANEL DOOR IN THE IFS ELECTRICAL PANEL AND ON THE FINAL VISIT CHECK LIST. 4. IN THE EVENT THERE ARE OPEN ITEMS, THE CONTRACTOR MUST CORRECT THEM AND RESCHEDULE THE FINAL INSPECTION WITH MANUFACTURER. GC IS RESPONSIBLE FOR REPLACEMENT OF SHEAVES, PULLEYS, AND BELTS, IF NEEDED. 5. THE HVAC CONTROL NUMBER WILL BE ISSUED AT THE END OF THE VISIT PROVIDED THERE ARE NO UNRESOLVED HVAC PUNCHLIST ITEMS, THE TRANE TECHNICIAN WILL WRITE THE HVAC CONTROL NUMBER ON THE STICKER INSIDE THE WR CONTROLS PANEL (IFS PANEL) AND ON THE FINAL VISIT CHECK LIST. MECHANICAL NOTES AND SPECIFICATIONS NTS OODMO23JOSPEC F AIR HANDLING UNIT SCHEDULE (SPLIT DX) 1. S-EIRD SCREEN, 5- BACKDRAFT DAMPER, S- DISCONNECT SWITCH. NOTES: 1. INTERLOCK WITH LIGHTS. MECHANICAL EQUIPMENT SCHEDULES AIR DEVICE SCHEDULE NTS OODMO23F4SCHD NTS OODMO23EOSCHD �I!I 7 S.D. R.G. NEW SUPPLY AIR DIFFUSER NEW RETURN AIR GRILLE EXISTING SUPPLY AIR DIFFUSER EXISTING RETURN AIR GRILLE ACCESS PANEL EXHAUST AIR REGISTER LD(1) 3/4" 6' LINEAR DIFFUSER NOTATION APPROX. LENGTH, 6 FT SLOT WIDTH, 3/4 IN. NO. OF SLOTS, 1 LINEAR DIFFUSER '---- SHEET METAL PLENUM WITH 1/2" LINING CARBON DIOXIDE SENSOR HUMIDISTAT TEMPERATURE SENSOR THERMOSTAT NEW DUCTWORK ! NEW DUCTWORK i EXISTING DUCTWORK TO REMAIN MVD CFSD FD 0 ABD 8 -- OBD (R) EXISTING DUCTWORK TO BE REMOVED FLEXIBLE AIR DUCT 4'--0" MAX. MANUAL VOLUME DAMPER COMBINATION FIRE /SMOKE DAMPER FIRE DAMPER AUTOMATIC BACKDRAFT DAMPER UNDERCUT DOOR OPPOSED BLADE DAMPER RELOCATED DUCT SMOKE DETECTOR POINT OF CONNECTION LEGEND AND SYMBOLS NTS OODMO23DOSYMB 0 0 0 0 0 0 0 12 13 14 TEMPERATURE AND CARBON DIOXIDE SENSORS FURNISHED BY MANUFACTURER, INSTALLED AND WIRED BY MECHANICAL CONTRACTOR 48" A.F.F. SEE SHEET M04.1 FOR RESPONSIBILITY SCHEDULE. AHU -1: ESD &C SHALL PROVIDE AND MECHANICAL INSTALL A SPLIT SYSTEM DX AIR HANDLING UNIT HORIZONTALLY. INSTALL WITH PROPER SERVICE CLEARANCE AREA AS RECOMMENDED BY MANUFACTURER AND AS SHOWN ON PLANS. MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL STRUCTURAL STEEL, VIBRATION ISOLATION, SECONDARY DRAIN PAN, CONDENSATE PUMP, AND 3 SETS OF FILTERS. CHANGE FILTER AFTER FINAL CLEANING AND AGAIN PRIOR TO AIR BALANCE. SEE AIR HANDLING UNIT SCHEDULE FOR FURTHER INFORMATION. COORDINATE WITH EXISTING STRUCTURE. FIELD VERIFY EXISTING CONDITIONS. SUPPLY AND RETURN AIR DUCT CONNECTIONS TO AHU SHALL BE MADE FULL SIZE OF EQUIPMENT OPENING WITH FLEXIBLE DUCT CONNECTIONS AT UNIT. TRANSITION AS REQUIRED. SUPPLY AIR TEMPERATURE SENSOR FURNISHED BY MANUFACTURER, INSTALLED AND WIRED IN DUCT BY MECHANICAL CONTRACTOR. SEE SHEET M04.1 FOR RESPONSIBILITY SCHEDULE. DUCT MOUNTED RETURN AIR SMOKE DETECTOR FURNISHED BY FIRE ALARM CONTRACTOR AND INSTALLED IN DUCT BY MECHANICAL CONTRACTOR. POWER WIRING SHALL BE PROVIDED BY ELECTRICAL CONTRACTOR. INTERLOCK TO SHUT DOWN UNIT ON SIGNAL FROM FIRE ALARM SYSTEM. MECHANICAL CONTRACTOR SHALL PROVIDE OUTSIDE AIR DUCT WITH A GRAVITY BACKDRAFT DAMPER AND BALANCE DAMPER. SEE AIR HANDLING UNIT SCHEDULE FOR OUTSIDE AIR QUANTITIES. ECONOMIZER CONTROL, RETURN AIR AND OUTSIDE AIR DAMPERS FURNISHED BY ESD &C AND INSTALLED BY MECHANICAL CONTRACTOR. ELECTRIC ACTUATORS FURNISHED BY ESD &C AND INSTALLED BY MECHANICAL CONTRACTOR. MECHANICAL CONTRACTOR IS TO MAKE ALL FINAL CONTROL WIRING CONNECTIONS TO THE TEMPERATURE CONTROL SYSTEM AND AT THE DAMPER ACTUATOR. COORDINATE WITH MALL OPERATIONS MANAGER. IH -1: THE MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL A ROOF MOUNTED INTAKE HOOD. INTAKE HOOD SHALL HAVE A CAPACITY OF 8000 CFM 0 MAXIMUM 0,1" PRESSURE DROP, UNIT SHALL BE COMPLETE WITH, INTEGRAL METAL BIRD SCREEN AND A ROOF CURB. ROOF CURB AND INTAKE HOOD SHALL BE MOUNTED BY THIS CONTRACTOR. ALL ROOF WORK SHALL BE PERFORMED BY LANDLORD'S APPROVED ROOFING CONTRACTOR AT THIS CONTRACTOR'S EXPENSE. RH -1: THE MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL A ROOF MOUNTED RELIEF HOOD. UNIT SHALL HAVE A CAPACITY OF 8000 CFM 0 MAXIMUM 0.1" PRESSURE DROP. UNIT SHALL BE COMPLETE WITH A GRAVITY BACKDRAFT TYPE DAMPER, INTEGRAL METAL BIRD SCREEN AND ROOF CURB. ROOF CURB AND RELIEF HOOD SHALL BE MOUNTED BY THIS CONTRACTOR. ALL ROOF WORK SHALL BE PERFORMED BY LANDLORD'S APPROVED ROOFING CONTRACTOR AT THIS CONTRACTOR'S EXPENSE. ACCU -1: ESD &C SHALL PROVIDE AND MECHANICAL CONTRACTOR SHALL INSTALL AN AIR COOLED DX CONDENSING UNIT ON ROOF IN A LANDLORD APPROVED LOCATION. INSTALL WITH PROPER SERVICE CLEARANCE AREA AS RECOMMENDED BY MANUFACTURER. PROVIDE STRUCTURAL SUPPORT AS REQUIRED. CONTRACTOR MUST VERIFY MODEL NUMBERS AND ELECTRICAL REQUIREMENTS PRIOR TO INSTALLATION. SEE AIR COOLED CONDENSING UNIT SCHEDULE FOR ADDITIONAL INFORMATION. FIELD LOCATE ROUTING OF REFRIGERANT PIPING. SEAL ROOF PENETRATION WATER TIGHT. COORDINATE WITH GENERAL CONTRACTOR. ALL ROOF WORK SHALL BE PERFORMED BY LANDLORD'S APPROVED ROOFING CONTRACTOR AT THIS CONTRACTOR'S EXPENSE. HVAC CONTRACTOR SHALL EXTEND REFRIGERANT LINES FROM AIR COOLED CONDENSING UNITS TO THE AIR HANDLING UNITS AND MAKE FINAL CONNECTIONS. REFRIGERANT LINES SHALL BE SIZED PER MANUFACTURER'S RECOMMENDATIONS. PROVIDE SHUT -OFF VALVES, CHARGING PORTS, FILTER DRYERS, SIGHT GLASSES, 24 VOLT SOLENOID VALVES, THERMAL EXPANSION VALVES, AND ALL ITEMS REQUIRED FOR A COMPLETE AND FUNCTIONING REFRIGERATION SYSTEM. INSULATE SUCTION LINE AND SIZE REFRIGERANT LINES PROPERLY FOR DISTANCE, NUMBER OF FITTINGS AND HEIGHT OF LIQUID LIFT. FIELD VERIFY IF EXISTING PAHWAY CAN BE USED. TENANT CONTRACTOR SHALL FIELD VERIFY EXACT LOCATION OF ALL HVAC EQUIPMENT. COORDINATE WITH LANDLORD ENGINEER PRIOR TO BID AND CONSTRUCTION. MECHANICAL CONTRACTOR TO PROVIDE NEW CEILING MOUNTED EXHAUST FAN, COMPLETE WITH INTEGRAL BACKDRAFT DAMPER. EXHAUST CAPACITY SHALL BE 75 CFM AT 0.5" S.P. INSTALL AND SECURE PER MANUFACTURE'S INSTRUCTIONS. EXTEND TO ROOF PENETRATION WITH ROOF CAP AND CURB. FIELD VERIFY EXACT LOCATION AND REQUIREMENTS. ALL ROOF WORK SHALL BE PERFORMED BY LANDLORD'S APPROVED ROOFING CONTRACTOR AT THIS CONTRACTOR'S EXPENSE. PROVIDE AN OPENING, SIZE AS NOTED ON PLANS, IN WALL ABOVE CEILING FOR RETURN AIR. CODED NOTES AABC A/C ABV AD AID AFF AHU AP ASHRAE BDD BEL BHP BLDG BOO BOP BTUH CAP CD CFM CHWR CHWS CLG CONN CONT CONTR COP CSFD CWR CWS DB DEG DET DIA DIM DISCH DL ON DTR DWG EA EAG EAR EAT EC EER EF EFF EG ELEC ELV ENCL EQUIV ESP EWC EXH (E) F FCU FLA FLEX FLR FPM FPS G GAL GALV GC GPM HO HP HTR HVAC HWR HWS AMERICAN AIR BALANCE COUNCIL AIR CONDITIONING UNIT ABOVE ACCESS DOOR APPROVED FIRE DAMPER ABOVE FINISH FLOOR AIR HANDLING UNIT ACCESS PANEL AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR CONDITIONING ENGINEERS BACK DRAFT DAMPERS BELOW BRAKE HORSEPOWER BUILDING BOTTOM OF DUCT BOTTOM OF PIPE BRITISH THERMAL UNIT PER HOUR CAPACITY CEILING DIFFUSER OR CONDENSATE DRAIN CUBIC FEET PER MINUTE CHILLED WATER RETURN CHILLED WATER SUPPLY CEILING, COOLING CONNECTION OR CONNECTOR CONTINUOUS CONTRACTOR COEFFICIENT OF PERFORMANCE COMBINATION FIRE /SMOKE DAMPER CONDENSER WATER RETURN CONDENSER WATER SUPPLY DRY BULB, DECIBEL DEGREE DETAIL DIAMETER DIMENSION DISCHARGE DOOR LOUVER DOWN DOWN THRU ROOF DRAWING EXHAUST AIR EXHAUST AIR GRILLE EXHAUST AIR REGISTER ENTERING AIR TEMPERATURE ELECTRICAL CONTRACTOR ENERGY EFFICIENCY RATIO EXHAUST FAN EFFICIENCY EXHAUST GRILLE ELECTRIC ELEVATION ENCLOSURE EQUIVALENT EXTERNAL STATIC PRESSURE ELECTRIC WATER COOLER EXHAUST EXISTING FAHRENHEIT FAN COIL UNIT FULL LOAD AMPS FLEXIBLE FLOOR FEET PER MINUTE FEET PER SECOND GAS GALLONS GALVANIZED GENERAL CONTRACTOR GALLONS PER MINUTE HEAD HORSEPOWER HEATER HEATING VENTILATING AND HOT WATER RETURN HOT WATER SUPPLY ID INSIDE DIAMETER IN INCH KW KILOWATT L LB LF LIN DIFF MAX MBH MCA MD MECH MFR MOCP MTD MTR NEBB N.C. N.I.C. N.O. N/A NTS (N) OBD OD OPNG OSA PD PLBG POC PRV PSI RA RAG RAR RG RH RPM SA SAG SAR SCH SENS SF SMACNA SOY SP SQ SOFT SS TEMP TO TSP TSTAT TYP UC UH UON UTR VAV VENT VFD VTR WB AIR CONDITIONING WCO WG WT LONG POUND LINEAR FEET LINEAR DIFFUSER MAXIMUM THOUSAND BTU PER HOUR MINIMUM CIRCUIT AMPACITY MOTORIZED DAMPER MECHANICAL MANUFACTURER MAXIMUM OVER CURRENT PROTECTION MOUNTED MOTOR NATIONAL ENVIRONMENTAL BALANCING BUREAU NORMALLY CLOSED NOT IN CONTRACT NORMALLY OPEN NOT APPLICABLE NOT TO SCALE NEW OPPOSED BLADE DAMPER OUTSIDE DIMENSION OR DIAMETER OPENING OUTDOOR AIR PUMP PRESSURE DROP PLUMBING POINT OF CONNECTION PRESSURE REDUCING VALVE POUNDS PER SQUARE INCH RETURN AIR RETURN AIR GRILLE RETURN AIR REGISTER RETURN GRILLE RELATIVE HUMIDITY REVOLUTIONS PER MINUTE SUPPLY AIR SUPPLY AIR GRILLE SUPPLY AIR REGISTER SCHEDULE SENSIBLE SUPPLY FAN, SQUARE FOOT SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION SHUT -OFF VALVE STATIC PRESSURE SQUARE SQUARE FEET STAINLESS STEEL TEMPERATURE TRANSFER GRILLE TOTAL STATIC PRESSURE THERMOSTAT TYPICAL UNDERCUT UNIT HEATER UNLESS OTHERWISE NOTED UP THRU ROOF VARIABLE AIR VOLUME VENTILATION, VENTILATOR VARIABLE FREQUENCY DRIVE VENT THRU ROOF WATT WET BULB WALL CLEANOUT WATER GAUGE WEIGHT MECHANICAL ABBREVIATION DEFINITIONS REVIEWED FO CODE COMPLIANCE APPR VEDA MAY - 8 2008 City Of Tukwila B ILDIN : DIVISJOk. CITY OF TUKWILA APR 2 9 2008 PERMIT CLAVIER NTS OODMO23COCODE NTS OODMO23AOABRV SHREMSHOCK 6130 S. WESTERVI 614-545 2 W W W = < w N S' U O U 0 N 0 N < Z 0 Q U 0 1- Lel p?o Z CY at e w a ce CY� W W W_ W = 0 W o - w= U W h . W CC 0 W X z o W N Qp w$ N LL; K 2 z0 AJ o O O o z Z W = z ; ;-- 4 - O O N J ° [ W X 2 a O a 00 O 0 0 0 DATE ISSUED: DESIGNED BY: DRAWN BY: CHECKED BY: z • INDICATES NO REVISION TO THIS SHEET U REVISIONS: GINEERING, INC. OAD Oat- Z Z Z w C 5 I-- LU co 0 W CI: Emm X co W 0 oUiv U W CC O V o 2 &W < � a0r -0o ~ W 2 w 2 2<51 ; N�N a CY 0 0 0 0 0 w w . N 0 LO in rn Cp 0 0 00 CI_ QQ F- U w w O e IX O- IL w 0- 0 4 W I- - 0 co 0 00 W Q Q CO Q CO i. L5 co 0) 1.111 --1 161 0 ct W rr)P CL Ix 0_ . I V) OL X cn I d 0 C? W d . < Ov9 III il: [L D w O I v) t!} toC1LU REQUIRED BY: DATE 04/18/2008 BJD BJD JTP MECHANICAL PLAN NOTES AND SCHEDULE DRAWING NUMBER: vs( FILTER DRIER SIGHT GLASS LIN. FT. SLOPE UCTION LINE ID LINE IF APPLICABLE NOTE: SIZING OF REFRIGERANT L BE DETERMINED BY MA CONTRACTOR SHALL DIMENSIONED S RISES, RUNS MANUFAC WRITT CO NOTE: 1. DESIGN ENGINEER TO PROV 2. IF MUFFLER IS INDICA OPTIONS OF SOUN OIL TR (TYP AT EVERY SUCTIO FAN COIL UNIT FLOW DIAGRAM. , REVIEW THE ADDITIONAL ACKET OVER COMPRESSOR. FROM COMPRESSOR IN HOT GAS LINE. LOCATE AS AS POSSIBLE TO COMPRESSOR DISC GLE CIRCUIT REFRIGERANT PIPING DETAIL PITCH IF INDICATED CONDENSING UNIT 0 RECEIVER MUFFLER S SHALL FACTURER. OVIDE A H SHOWING BOWS, ETC. ER WILL PROVIDE DOCUMENTATION TO ACTOR VERIFYING THE PROPRIATE LINE SIZES TO BE USED. ONLY RIGID COPPER PIPING SHALL BE INSTALLED. SEE SPECIFICATION (SHEET M01.1) FOR MORE DETAILS. LIQUID LINE TO CONDENSER LOCKING QUADRANT ROUND DAMPER YOUNG REGULATOR MODEL 5020CC (830ACC FOR RECTANGULAR) RIGID DUCTWORK, INSULATED PER SPECIFICATIONS DUCT STRAP AND FOIL TAPE EXTENDED ADJUSTMEN HANDLE NOTE: FOR REMOTE DAMP L FLEXIBLE CASING AND WIRE (30' -0" MAXIMUM) RACK & PINION OPERATOR DIE CAST MOUNTING CUP COVER PLATE 90' ELBOW DUCT STRAP AND FOIL TAPE G DIFFUSER REGULATOR KIT FLEXIBLE DUCTWORK NO LONGER THAN 3' -O" ADJUSTMENT - J CEI CONCEA SOCKET WRENC NOTE: COORDINATE EXACT LOCATION OF CEILING MOUNTED CONCEALED REGULATOR WITH ARCHITECT PRIOR TO INSTALLATION. UNG REGULATOR REMOTE DAMPER TOILET EXHAUST IN -LINE FAN EXHAUS FROM CEILING EXHAUST GRILLE W /HARD DUCT CONNECTION cii III 1 0 II FACTORY MOUNTING B SECURED TO CEILING OR CEILING JOIST (TYP) ILET EXHAUST IN -LINE MOUNTING DETAIL CONCENTRIC TRANSITION 0 - MAX. 45" DIVERGING, 60' CONVERGING RECTANGULAR DUCT AIR FLOW 45" SADDLE TAP 0 RECTANGULAR TO ROUND AI FLOW LOW CD ROUND TO ROUND D ECCENTRIC TRANSITION 0 - MAX. 30' (EXCEPT 45' IS PERMITTED AT ROUND TO FLAT OVAL) 0 RECTANGULAR TO ROUND AIR FLOW r ity Of Tukwila I CON TTING SEA _. AIRTIGHT W /MASTIC ROUND DUCT BRANCH DUCT 0 RECTANGULAR TO RECTANGULAR DUCT DETAILS ' ‚ p DAMPER HANDLE TO BE INSTALLED MAXIMUM OF 3' -O" ABOVE CEILING. ROUND DUCT 18" LONG ORANGE MARKER TAPE ATTACHED TO DAMPER TO IDENTIFY LOCATION INSULATED FLEXIBLE CONNECTION (MIN. 3 FT., MAX. 4 FT.) FIRE DAMPER WHERE INDICATED ON PLANS. TITUS MODEL "DB" DIRECTIONAL BLOW PLATE CLIPPED ON DIFFUSER RODS. SEE NOTE BELOW. SUPPLY AIR DIFFUSER (LAY -IN FRAME) WITH MANUAL VOLUME DAMPER PROVIDE VOLUME DAMPER WITH LOCKING QUADRANT. PROVIDE WITH 3" EXTENDED SHAFT AND HANDLE (SEE SPEC SECTION 233300 D. 1.) SHT. MTL. ELBOW REQUIRED SECURELY TAPE VINYL FLEX DUCT TO SHT. MTL. W/ MIN, OF (2) CONTINUOUS WRAPS OF DUCT TAPE. STRAP CLAMP OVER FLEX DUCT INSULATION & VINYL TO SHT. MTL. TAPE INSULATION TO DUCT TO FORM A GOOD SEAL 8" LONG SHT. MTL SECTION SECURED TO DIFFUSER COLLAR W/ MIN. (3) SHT. MTL. SCREWS, DUCT TAPE AND MASTIC. TRANSITION FROM DUCT SIZE TO DIFFUSER NECK SIZE AS NECESSARY THERMAL INSULATING BLANKET REQUIRED FOR FIRE RATED CEILINGS ONLY. CEILING MOUNTING FRAME FOR GYP. BD. APPLICATION TITUS MODEL TRM, SEE DETAIL E THIS SHEET NOTE: ALL DIFFUSERS ARE 4 -WAY BLOW UNLESS NOTED OTHERWISE. PROVIDE OPTIONAL DIRECTIONAL BLOW, TITUS MODEL "DB" TO CONVERT DIFFUSER FROM STANDARD 4-WAY TO 1 -WAY, 2 -WAY OR 3 -WAY BLOW AS DESIGNATED ON PLANS BY SHADED AREA. I," UP THRU ROOF OR L.L. EXHAUST MAIN CK ET ALL JOIST OODMO31BODUCT NTS OODM031AODIFF WOOD NAILER COUNTERFLASHING EQUIPMENT SUPPORT RAIL (PATE ES -5 OR APPROVED EQUAL.) ROOF INSULATION - ROOF STRUCTURE BASE PLATE NOTE: CONDENSING UNIT vAraw PROVIDE RUBBER FLOOR MATTS AROUND ALL ROOFTOP EQUIPMENT LAG BOLT NEOPRENE WASHER NAIL LAG BOLTS ROOFING MOUNTING DETAIL FOR CONDENSING UNIT NTS OODMO31LOUNIT L NOTE: FAN COIL UNIT PITCH r d QB IF INDICATED CONDENSING UNIT ROOF I TXV FILTER DRIER SIGHT GLASS 1/4" / LIN. FT. SLOPE -,+ SUCTION LINE LIQUID LINE OIL TRAP (TYP AT EVERY SUCTION RISER) 1. IF MUFFLER IS INDICATED, REVIEW THE ADDITIONAL OPTIONS OF SOUND JACKET OVER COMPRESSOR. IF APPLICABLE 0 RECEIVER Q MUFFLER NOTE: SIZING OF REFRIGERANT LINES SHALL BE DETERMINED BY MANUFACTURER. CONTRACTOR SHALL PROVIDE A DIMENSIONED SKETCH SHOWING RISES, RUNS, ELBOWS, ETC. MANUFACTURER WILL PROVIDE WRITTEN DOCUMENTATION TO CONTRACTOR VERIFYING THE APPROPRIATE LINE SIZES TO BE USED. ONLY RIGID COPPER PIPING SHALL BE INSTALLED. SEE SPECIFICATION (SHEET M01.1) FOR MORE DETAILS. jr" LIQUID LINE FROM COMPRESSOR D- TO CONDENSER IN HOT GAS LINE. LOCATE AS CLOSE AS POSSIBLE TO COMPRESSOR DISCHARGE. DOUBLE CIRCUIT REFRIGERANT PIPING DETAIL NTS OODM031KOPIPE NTS OODM031JOPIPE K NEW 24 GA. G.I. COVER PLATE - NOTCH TO FIT PIPES NEW 24 GA. G.I. MULTIPLE PIPE ENCLOSURE ASSEMBLY - FASTEN TO CURB USING NEW 3/8" HEAD SCREWS THROUGH 5/8" STEEL/ NEOPRENE WASHERS - MIN. 3 PER SIDE. NEW 4" FIREPROOF INSULATION STRIP IIs, - �� NEW 2x10 WOOD CURB ;(I� CAVITY TO BE FOAM FILLED II NEW 2x4 WOOD NAILER SECURED TO UNDERLYING DECK 1i NEW PIPES NEW FIBERGLASS BASE SHEET - MECHANICALLY FASTENED NEW MODIFIED BITUMEN FLASHING MEMBRANE - TORCH - APPLIED NEW 3 "x3" CONTINUOUS 20 GA. G.I. METAL - SECURE TO DECK USING SCREWS SPACED AT 8" O.C. EXISTING ROOF INSULATION EXISTING BUILT -UP ROOFING EXISTING STEEL DECK NOTES: ALL PIPES ENTERING THE PIPE ENCLOSURE ASSEMBLY SHALL BE SLOPED UPWARD AS THEY ENTER THE FLASHING SO THAT WATER WILL NOT BE ABLE TO RUN INTO THE BUILDING. PIPE TROUGH ROOF DETAIL SUPPORT FROM STRUCTURE ABOVE WITH CHANNEL AND THREADED ROD. HANG PER SMACNA. FAN SECTION BY UNIT SUPPLIER FLEXIBLE DUCT CONNECTOR INSULATE SUCTION LINE WITH 1/2" FLEXIBLE UNICELLULAR INSULATION. NOTE: REFER TO COIL PIPING DETAILS FOR ADDITIONAL REQUIREMENTS. J Et L SECONDARY DRAIN PAN. OUTSIDE AIR DUCT ECONOMIZER MIXING BOX SECTION FLAT FILTER SECTION I " '1 L CONDENSATE DRAIN. REFER TO PLAN FOR SIZE AND ROUTE. INTEGRAL OVERFLOW LEVEL FLOAT SWITCH BY HVAC SUPPLIER. PARALLEL BLADE DAMPERS (TYP.) RETURN AIR DUCT. (LINE IF REQUIRED) SPLIT DX AHU MOUNTING DETAIL .! DRYWALL CEILING DIFF. MTG. FRAME DETAIL NTS 003M031HOPTRD NTS OODM031G2UNIT NTS O03M031FODAMP NTS OODMO31EOFRME H 25 1/4" OR 13 1/4" 24" OR 12" NOTE: ROUGH -IN OPENING SIZES: NOMINAL 12 "x 12 = 12 1/2 "x 12 1/2" NOMINAL 12 "x 24 = 12 1/2 "x 24 1/2" NOMINAL 24 "x 24" = 24 1/2 "x 24 1/2" "C" CHANNEL REINFORCING BY G.C. AROUND OPENING MOUNTING SCREW FIELD IN STALLED GYP. BD. CEILING STEEL MOUNTING FRAME CAP STORM COLLAR FLASHING BY G.G. EXH. DUCT FROM RESTROOM ROOF 24" DUCT SUPPORT FASTENED TO NEAREST ROOF STRUCTURAL MEMBER. SIZE PER SMACNA GUIDELINES. EXHAUST AIR DUCT ASSEMBLY DETAIL CEILING DIFFUSER MOUNTING DETAIL NTS OODMO31DOEXDT NTS OODMO31COEFAN D SHREMSHOCK 6130 S. WESTERVI 614 -545 REQUIRED BY: REVISIONS: INDICATES NO REVISION TO THIS SHEET DATE ISSUED: DESIGNED BY: DRAWN BY: CHECKED BY: GINEERING, INC. AD 81 :: O 2 CC 0 ILI Z O 5 W U) a RECEIVED CITY Ur IT iKVViLH APR 2 7008 DRAWING NUMBER: V = Ora = l U O C � w L _ 0 Ln p F O W = -y 4 V gQ = p h d = U F 0 CE C F = O C U N VE wti"K LU 0 a C) D Y J ° w O C Z E ( 3 W = a =? w = U O • J c. a Z N x 6 5E C CE 0 W W W 4 ~ p 4 V 21 H 0 J Q 2 H CD 62 = z O _ V ] E Ifi d W V li = V i V o O W 4 T ci W W m O 2 E. - w N J N 03 a) o r o 00 co LL a I— U 0 • Ce 0. IC w L J La a (,D 4 X w Z Q In III 1 �C]w U w 9 (/ 2 (f) (n [� < Q 0 I- DATE 04/18/2008 BJD BJD JTP MECHANICAL DETAILS �, l l i \ / OUTSIDE DIMENSION U FILTER DRIER SIGHT GLASS LIN. FT. SLOPE UCTION LINE ID LINE IF APPLICABLE NOTE: SIZING OF REFRIGERANT L BE DETERMINED BY MA CONTRACTOR SHALL DIMENSIONED S RISES, RUNS MANUFAC WRITT CO NOTE: 1. DESIGN ENGINEER TO PROV 2. IF MUFFLER IS INDICA OPTIONS OF SOUN OIL TR (TYP AT EVERY SUCTIO FAN COIL UNIT FLOW DIAGRAM. , REVIEW THE ADDITIONAL ACKET OVER COMPRESSOR. FROM COMPRESSOR IN HOT GAS LINE. LOCATE AS AS POSSIBLE TO COMPRESSOR DISC GLE CIRCUIT REFRIGERANT PIPING DETAIL PITCH IF INDICATED CONDENSING UNIT 0 RECEIVER MUFFLER S SHALL FACTURER. OVIDE A H SHOWING BOWS, ETC. ER WILL PROVIDE DOCUMENTATION TO ACTOR VERIFYING THE PROPRIATE LINE SIZES TO BE USED. ONLY RIGID COPPER PIPING SHALL BE INSTALLED. SEE SPECIFICATION (SHEET M01.1) FOR MORE DETAILS. LIQUID LINE TO CONDENSER LOCKING QUADRANT ROUND DAMPER YOUNG REGULATOR MODEL 5020CC (830ACC FOR RECTANGULAR) RIGID DUCTWORK, INSULATED PER SPECIFICATIONS DUCT STRAP AND FOIL TAPE EXTENDED ADJUSTMEN HANDLE NOTE: FOR REMOTE DAMP L FLEXIBLE CASING AND WIRE (30' -0" MAXIMUM) RACK & PINION OPERATOR DIE CAST MOUNTING CUP COVER PLATE 90' ELBOW DUCT STRAP AND FOIL TAPE G DIFFUSER REGULATOR KIT FLEXIBLE DUCTWORK NO LONGER THAN 3' -O" ADJUSTMENT - J CEI CONCEA SOCKET WRENC NOTE: COORDINATE EXACT LOCATION OF CEILING MOUNTED CONCEALED REGULATOR WITH ARCHITECT PRIOR TO INSTALLATION. UNG REGULATOR REMOTE DAMPER TOILET EXHAUST IN -LINE FAN EXHAUS FROM CEILING EXHAUST GRILLE W /HARD DUCT CONNECTION cii III 1 0 II FACTORY MOUNTING B SECURED TO CEILING OR CEILING JOIST (TYP) ILET EXHAUST IN -LINE MOUNTING DETAIL CONCENTRIC TRANSITION 0 - MAX. 45" DIVERGING, 60' CONVERGING RECTANGULAR DUCT AIR FLOW 45" SADDLE TAP 0 RECTANGULAR TO ROUND AI FLOW LOW CD ROUND TO ROUND D ECCENTRIC TRANSITION 0 - MAX. 30' (EXCEPT 45' IS PERMITTED AT ROUND TO FLAT OVAL) 0 RECTANGULAR TO ROUND AIR FLOW r ity Of Tukwila I CON TTING SEA _. AIRTIGHT W /MASTIC ROUND DUCT BRANCH DUCT 0 RECTANGULAR TO RECTANGULAR DUCT DETAILS ' ‚ p DAMPER HANDLE TO BE INSTALLED MAXIMUM OF 3' -O" ABOVE CEILING. ROUND DUCT 18" LONG ORANGE MARKER TAPE ATTACHED TO DAMPER TO IDENTIFY LOCATION INSULATED FLEXIBLE CONNECTION (MIN. 3 FT., MAX. 4 FT.) FIRE DAMPER WHERE INDICATED ON PLANS. TITUS MODEL "DB" DIRECTIONAL BLOW PLATE CLIPPED ON DIFFUSER RODS. SEE NOTE BELOW. SUPPLY AIR DIFFUSER (LAY -IN FRAME) WITH MANUAL VOLUME DAMPER PROVIDE VOLUME DAMPER WITH LOCKING QUADRANT. PROVIDE WITH 3" EXTENDED SHAFT AND HANDLE (SEE SPEC SECTION 233300 D. 1.) SHT. MTL. ELBOW REQUIRED SECURELY TAPE VINYL FLEX DUCT TO SHT. MTL. W/ MIN, OF (2) CONTINUOUS WRAPS OF DUCT TAPE. STRAP CLAMP OVER FLEX DUCT INSULATION & VINYL TO SHT. MTL. TAPE INSULATION TO DUCT TO FORM A GOOD SEAL 8" LONG SHT. MTL SECTION SECURED TO DIFFUSER COLLAR W/ MIN. (3) SHT. MTL. SCREWS, DUCT TAPE AND MASTIC. TRANSITION FROM DUCT SIZE TO DIFFUSER NECK SIZE AS NECESSARY THERMAL INSULATING BLANKET REQUIRED FOR FIRE RATED CEILINGS ONLY. CEILING MOUNTING FRAME FOR GYP. BD. APPLICATION TITUS MODEL TRM, SEE DETAIL E THIS SHEET NOTE: ALL DIFFUSERS ARE 4 -WAY BLOW UNLESS NOTED OTHERWISE. PROVIDE OPTIONAL DIRECTIONAL BLOW, TITUS MODEL "DB" TO CONVERT DIFFUSER FROM STANDARD 4-WAY TO 1 -WAY, 2 -WAY OR 3 -WAY BLOW AS DESIGNATED ON PLANS BY SHADED AREA. I," UP THRU ROOF OR L.L. EXHAUST MAIN CK ET ALL JOIST OODMO31BODUCT NTS OODM031AODIFF WOOD NAILER COUNTERFLASHING EQUIPMENT SUPPORT RAIL (PATE ES -5 OR APPROVED EQUAL.) ROOF INSULATION - ROOF STRUCTURE BASE PLATE NOTE: CONDENSING UNIT vAraw PROVIDE RUBBER FLOOR MATTS AROUND ALL ROOFTOP EQUIPMENT LAG BOLT NEOPRENE WASHER NAIL LAG BOLTS ROOFING MOUNTING DETAIL FOR CONDENSING UNIT NTS OODMO31LOUNIT L NOTE: FAN COIL UNIT PITCH r d QB IF INDICATED CONDENSING UNIT ROOF I TXV FILTER DRIER SIGHT GLASS 1/4" / LIN. FT. SLOPE -,+ SUCTION LINE LIQUID LINE OIL TRAP (TYP AT EVERY SUCTION RISER) 1. IF MUFFLER IS INDICATED, REVIEW THE ADDITIONAL OPTIONS OF SOUND JACKET OVER COMPRESSOR. IF APPLICABLE 0 RECEIVER Q MUFFLER NOTE: SIZING OF REFRIGERANT LINES SHALL BE DETERMINED BY MANUFACTURER. CONTRACTOR SHALL PROVIDE A DIMENSIONED SKETCH SHOWING RISES, RUNS, ELBOWS, ETC. MANUFACTURER WILL PROVIDE WRITTEN DOCUMENTATION TO CONTRACTOR VERIFYING THE APPROPRIATE LINE SIZES TO BE USED. ONLY RIGID COPPER PIPING SHALL BE INSTALLED. SEE SPECIFICATION (SHEET M01.1) FOR MORE DETAILS. jr" LIQUID LINE FROM COMPRESSOR D- TO CONDENSER IN HOT GAS LINE. LOCATE AS CLOSE AS POSSIBLE TO COMPRESSOR DISCHARGE. DOUBLE CIRCUIT REFRIGERANT PIPING DETAIL NTS OODM031KOPIPE NTS OODM031JOPIPE K NEW 24 GA. G.I. COVER PLATE - NOTCH TO FIT PIPES NEW 24 GA. G.I. MULTIPLE PIPE ENCLOSURE ASSEMBLY - FASTEN TO CURB USING NEW 3/8" HEAD SCREWS THROUGH 5/8" STEEL/ NEOPRENE WASHERS - MIN. 3 PER SIDE. NEW 4" FIREPROOF INSULATION STRIP IIs, - �� NEW 2x10 WOOD CURB ;(I� CAVITY TO BE FOAM FILLED II NEW 2x4 WOOD NAILER SECURED TO UNDERLYING DECK 1i NEW PIPES NEW FIBERGLASS BASE SHEET - MECHANICALLY FASTENED NEW MODIFIED BITUMEN FLASHING MEMBRANE - TORCH - APPLIED NEW 3 "x3" CONTINUOUS 20 GA. G.I. METAL - SECURE TO DECK USING SCREWS SPACED AT 8" O.C. EXISTING ROOF INSULATION EXISTING BUILT -UP ROOFING EXISTING STEEL DECK NOTES: ALL PIPES ENTERING THE PIPE ENCLOSURE ASSEMBLY SHALL BE SLOPED UPWARD AS THEY ENTER THE FLASHING SO THAT WATER WILL NOT BE ABLE TO RUN INTO THE BUILDING. PIPE TROUGH ROOF DETAIL SUPPORT FROM STRUCTURE ABOVE WITH CHANNEL AND THREADED ROD. HANG PER SMACNA. FAN SECTION BY UNIT SUPPLIER FLEXIBLE DUCT CONNECTOR INSULATE SUCTION LINE WITH 1/2" FLEXIBLE UNICELLULAR INSULATION. NOTE: REFER TO COIL PIPING DETAILS FOR ADDITIONAL REQUIREMENTS. J Et L SECONDARY DRAIN PAN. OUTSIDE AIR DUCT ECONOMIZER MIXING BOX SECTION FLAT FILTER SECTION I " '1 L CONDENSATE DRAIN. REFER TO PLAN FOR SIZE AND ROUTE. INTEGRAL OVERFLOW LEVEL FLOAT SWITCH BY HVAC SUPPLIER. PARALLEL BLADE DAMPERS (TYP.) RETURN AIR DUCT. (LINE IF REQUIRED) SPLIT DX AHU MOUNTING DETAIL .! DRYWALL CEILING DIFF. MTG. FRAME DETAIL NTS 003M031HOPTRD NTS OODM031G2UNIT NTS O03M031FODAMP NTS OODMO31EOFRME H 25 1/4" OR 13 1/4" 24" OR 12" NOTE: ROUGH -IN OPENING SIZES: NOMINAL 12 "x 12 = 12 1/2 "x 12 1/2" NOMINAL 12 "x 24 = 12 1/2 "x 24 1/2" NOMINAL 24 "x 24" = 24 1/2 "x 24 1/2" "C" CHANNEL REINFORCING BY G.C. AROUND OPENING MOUNTING SCREW FIELD IN STALLED GYP. BD. CEILING STEEL MOUNTING FRAME CAP STORM COLLAR FLASHING BY G.G. EXH. DUCT FROM RESTROOM ROOF 24" DUCT SUPPORT FASTENED TO NEAREST ROOF STRUCTURAL MEMBER. SIZE PER SMACNA GUIDELINES. EXHAUST AIR DUCT ASSEMBLY DETAIL CEILING DIFFUSER MOUNTING DETAIL NTS OODMO31DOEXDT NTS OODMO31COEFAN D SHREMSHOCK 6130 S. WESTERVI 614 -545 REQUIRED BY: REVISIONS: INDICATES NO REVISION TO THIS SHEET DATE ISSUED: DESIGNED BY: DRAWN BY: CHECKED BY: GINEERING, INC. AD 81 :: O 2 CC 0 ILI Z O 5 W U) a RECEIVED CITY Ur IT iKVViLH APR 2 7008 DRAWING NUMBER: V = Ora = l U O C � w L _ 0 Ln p F O W = -y 4 V gQ = p h d = U F 0 CE C F = O C U N VE wti"K LU 0 a C) D Y J ° w O C Z E ( 3 W = a =? w = U O • J c. a Z N x 6 5E C CE 0 W W W 4 ~ p 4 V 21 H 0 J Q 2 H CD 62 = z O _ V ] E Ifi d W V li = V i V o O W 4 T ci W W m O 2 E. - w N J N 03 a) o r o 00 co LL a I— U 0 • Ce 0. IC w L J La a (,D 4 X w Z Q In III 1 �C]w U w 9 (/ 2 (f) (n [� < Q 0 I- DATE 04/18/2008 BJD BJD JTP MECHANICAL DETAILS OUTSIDE DIMENSION A m 4 ... 23" OR 11" .4 INSIDE DIMENSION / -- FILTER DRIER SIGHT GLASS LIN. FT. SLOPE UCTION LINE ID LINE IF APPLICABLE NOTE: SIZING OF REFRIGERANT L BE DETERMINED BY MA CONTRACTOR SHALL DIMENSIONED S RISES, RUNS MANUFAC WRITT CO NOTE: 1. DESIGN ENGINEER TO PROV 2. IF MUFFLER IS INDICA OPTIONS OF SOUN OIL TR (TYP AT EVERY SUCTIO FAN COIL UNIT FLOW DIAGRAM. , REVIEW THE ADDITIONAL ACKET OVER COMPRESSOR. FROM COMPRESSOR IN HOT GAS LINE. LOCATE AS AS POSSIBLE TO COMPRESSOR DISC GLE CIRCUIT REFRIGERANT PIPING DETAIL PITCH IF INDICATED CONDENSING UNIT 0 RECEIVER MUFFLER S SHALL FACTURER. OVIDE A H SHOWING BOWS, ETC. ER WILL PROVIDE DOCUMENTATION TO ACTOR VERIFYING THE PROPRIATE LINE SIZES TO BE USED. ONLY RIGID COPPER PIPING SHALL BE INSTALLED. SEE SPECIFICATION (SHEET M01.1) FOR MORE DETAILS. LIQUID LINE TO CONDENSER LOCKING QUADRANT ROUND DAMPER YOUNG REGULATOR MODEL 5020CC (830ACC FOR RECTANGULAR) RIGID DUCTWORK, INSULATED PER SPECIFICATIONS DUCT STRAP AND FOIL TAPE EXTENDED ADJUSTMEN HANDLE NOTE: FOR REMOTE DAMP L FLEXIBLE CASING AND WIRE (30' -0" MAXIMUM) RACK & PINION OPERATOR DIE CAST MOUNTING CUP COVER PLATE 90' ELBOW DUCT STRAP AND FOIL TAPE G DIFFUSER REGULATOR KIT FLEXIBLE DUCTWORK NO LONGER THAN 3' -O" ADJUSTMENT - J CEI CONCEA SOCKET WRENC NOTE: COORDINATE EXACT LOCATION OF CEILING MOUNTED CONCEALED REGULATOR WITH ARCHITECT PRIOR TO INSTALLATION. UNG REGULATOR REMOTE DAMPER TOILET EXHAUST IN -LINE FAN EXHAUS FROM CEILING EXHAUST GRILLE W /HARD DUCT CONNECTION cii III 1 0 II FACTORY MOUNTING B SECURED TO CEILING OR CEILING JOIST (TYP) ILET EXHAUST IN -LINE MOUNTING DETAIL CONCENTRIC TRANSITION 0 - MAX. 45" DIVERGING, 60' CONVERGING RECTANGULAR DUCT AIR FLOW 45" SADDLE TAP 0 RECTANGULAR TO ROUND AI FLOW LOW CD ROUND TO ROUND D ECCENTRIC TRANSITION 0 - MAX. 30' (EXCEPT 45' IS PERMITTED AT ROUND TO FLAT OVAL) 0 RECTANGULAR TO ROUND AIR FLOW r ity Of Tukwila I CON TTING SEA _. AIRTIGHT W /MASTIC ROUND DUCT BRANCH DUCT 0 RECTANGULAR TO RECTANGULAR DUCT DETAILS ' ‚ p DAMPER HANDLE TO BE INSTALLED MAXIMUM OF 3' -O" ABOVE CEILING. ROUND DUCT 18" LONG ORANGE MARKER TAPE ATTACHED TO DAMPER TO IDENTIFY LOCATION INSULATED FLEXIBLE CONNECTION (MIN. 3 FT., MAX. 4 FT.) FIRE DAMPER WHERE INDICATED ON PLANS. TITUS MODEL "DB" DIRECTIONAL BLOW PLATE CLIPPED ON DIFFUSER RODS. SEE NOTE BELOW. SUPPLY AIR DIFFUSER (LAY -IN FRAME) WITH MANUAL VOLUME DAMPER PROVIDE VOLUME DAMPER WITH LOCKING QUADRANT. PROVIDE WITH 3" EXTENDED SHAFT AND HANDLE (SEE SPEC SECTION 233300 D. 1.) SHT. MTL. ELBOW REQUIRED SECURELY TAPE VINYL FLEX DUCT TO SHT. MTL. W/ MIN, OF (2) CONTINUOUS WRAPS OF DUCT TAPE. STRAP CLAMP OVER FLEX DUCT INSULATION & VINYL TO SHT. MTL. TAPE INSULATION TO DUCT TO FORM A GOOD SEAL 8" LONG SHT. MTL SECTION SECURED TO DIFFUSER COLLAR W/ MIN. (3) SHT. MTL. SCREWS, DUCT TAPE AND MASTIC. TRANSITION FROM DUCT SIZE TO DIFFUSER NECK SIZE AS NECESSARY THERMAL INSULATING BLANKET REQUIRED FOR FIRE RATED CEILINGS ONLY. CEILING MOUNTING FRAME FOR GYP. BD. APPLICATION TITUS MODEL TRM, SEE DETAIL E THIS SHEET NOTE: ALL DIFFUSERS ARE 4 -WAY BLOW UNLESS NOTED OTHERWISE. PROVIDE OPTIONAL DIRECTIONAL BLOW, TITUS MODEL "DB" TO CONVERT DIFFUSER FROM STANDARD 4-WAY TO 1 -WAY, 2 -WAY OR 3 -WAY BLOW AS DESIGNATED ON PLANS BY SHADED AREA. I," UP THRU ROOF OR L.L. EXHAUST MAIN CK ET ALL JOIST OODMO31BODUCT NTS OODM031AODIFF WOOD NAILER COUNTERFLASHING EQUIPMENT SUPPORT RAIL (PATE ES -5 OR APPROVED EQUAL.) ROOF INSULATION - ROOF STRUCTURE BASE PLATE NOTE: CONDENSING UNIT vAraw PROVIDE RUBBER FLOOR MATTS AROUND ALL ROOFTOP EQUIPMENT LAG BOLT NEOPRENE WASHER NAIL LAG BOLTS ROOFING MOUNTING DETAIL FOR CONDENSING UNIT NTS OODMO31LOUNIT L NOTE: FAN COIL UNIT PITCH r d QB IF INDICATED CONDENSING UNIT ROOF I TXV FILTER DRIER SIGHT GLASS 1/4" / LIN. FT. SLOPE -,+ SUCTION LINE LIQUID LINE OIL TRAP (TYP AT EVERY SUCTION RISER) 1. IF MUFFLER IS INDICATED, REVIEW THE ADDITIONAL OPTIONS OF SOUND JACKET OVER COMPRESSOR. IF APPLICABLE 0 RECEIVER Q MUFFLER NOTE: SIZING OF REFRIGERANT LINES SHALL BE DETERMINED BY MANUFACTURER. CONTRACTOR SHALL PROVIDE A DIMENSIONED SKETCH SHOWING RISES, RUNS, ELBOWS, ETC. MANUFACTURER WILL PROVIDE WRITTEN DOCUMENTATION TO CONTRACTOR VERIFYING THE APPROPRIATE LINE SIZES TO BE USED. ONLY RIGID COPPER PIPING SHALL BE INSTALLED. SEE SPECIFICATION (SHEET M01.1) FOR MORE DETAILS. jr" LIQUID LINE FROM COMPRESSOR D- TO CONDENSER IN HOT GAS LINE. LOCATE AS CLOSE AS POSSIBLE TO COMPRESSOR DISCHARGE. DOUBLE CIRCUIT REFRIGERANT PIPING DETAIL NTS OODM031KOPIPE NTS OODM031JOPIPE K NEW 24 GA. G.I. COVER PLATE - NOTCH TO FIT PIPES NEW 24 GA. G.I. MULTIPLE PIPE ENCLOSURE ASSEMBLY - FASTEN TO CURB USING NEW 3/8" HEAD SCREWS THROUGH 5/8" STEEL/ NEOPRENE WASHERS - MIN. 3 PER SIDE. NEW 4" FIREPROOF INSULATION STRIP IIs, - �� NEW 2x10 WOOD CURB ;(I� CAVITY TO BE FOAM FILLED II NEW 2x4 WOOD NAILER SECURED TO UNDERLYING DECK 1i NEW PIPES NEW FIBERGLASS BASE SHEET - MECHANICALLY FASTENED NEW MODIFIED BITUMEN FLASHING MEMBRANE - TORCH - APPLIED NEW 3 "x3" CONTINUOUS 20 GA. G.I. METAL - SECURE TO DECK USING SCREWS SPACED AT 8" O.C. EXISTING ROOF INSULATION EXISTING BUILT -UP ROOFING EXISTING STEEL DECK NOTES: ALL PIPES ENTERING THE PIPE ENCLOSURE ASSEMBLY SHALL BE SLOPED UPWARD AS THEY ENTER THE FLASHING SO THAT WATER WILL NOT BE ABLE TO RUN INTO THE BUILDING. PIPE TROUGH ROOF DETAIL SUPPORT FROM STRUCTURE ABOVE WITH CHANNEL AND THREADED ROD. HANG PER SMACNA. FAN SECTION BY UNIT SUPPLIER FLEXIBLE DUCT CONNECTOR INSULATE SUCTION LINE WITH 1/2" FLEXIBLE UNICELLULAR INSULATION. NOTE: REFER TO COIL PIPING DETAILS FOR ADDITIONAL REQUIREMENTS. J Et L SECONDARY DRAIN PAN. OUTSIDE AIR DUCT ECONOMIZER MIXING BOX SECTION FLAT FILTER SECTION I " '1 L CONDENSATE DRAIN. REFER TO PLAN FOR SIZE AND ROUTE. INTEGRAL OVERFLOW LEVEL FLOAT SWITCH BY HVAC SUPPLIER. PARALLEL BLADE DAMPERS (TYP.) RETURN AIR DUCT. (LINE IF REQUIRED) SPLIT DX AHU MOUNTING DETAIL .! DRYWALL CEILING DIFF. MTG. FRAME DETAIL NTS 003M031HOPTRD NTS OODM031G2UNIT NTS O03M031FODAMP NTS OODMO31EOFRME H 25 1/4" OR 13 1/4" 24" OR 12" NOTE: ROUGH -IN OPENING SIZES: NOMINAL 12 "x 12 = 12 1/2 "x 12 1/2" NOMINAL 12 "x 24 = 12 1/2 "x 24 1/2" NOMINAL 24 "x 24" = 24 1/2 "x 24 1/2" "C" CHANNEL REINFORCING BY G.C. AROUND OPENING MOUNTING SCREW FIELD IN STALLED GYP. BD. CEILING STEEL MOUNTING FRAME CAP STORM COLLAR FLASHING BY G.G. EXH. DUCT FROM RESTROOM ROOF 24" DUCT SUPPORT FASTENED TO NEAREST ROOF STRUCTURAL MEMBER. SIZE PER SMACNA GUIDELINES. EXHAUST AIR DUCT ASSEMBLY DETAIL CEILING DIFFUSER MOUNTING DETAIL NTS OODMO31DOEXDT NTS OODMO31COEFAN D SHREMSHOCK 6130 S. WESTERVI 614 -545 REQUIRED BY: REVISIONS: INDICATES NO REVISION TO THIS SHEET DATE ISSUED: DESIGNED BY: DRAWN BY: CHECKED BY: GINEERING, INC. AD 81 :: O 2 CC 0 ILI Z O 5 W U) a RECEIVED CITY Ur IT iKVViLH APR 2 7008 DRAWING NUMBER: V = Ora = l U O C � w L _ 0 Ln p F O W = -y 4 V gQ = p h d = U F 0 CE C F = O C U N VE wti"K LU 0 a C) D Y J ° w O C Z E ( 3 W = a =? w = U O • J c. a Z N x 6 5E C CE 0 W W W 4 ~ p 4 V 21 H 0 J Q 2 H CD 62 = z O _ V ] E Ifi d W V li = V i V o O W 4 T ci W W m O 2 E. - w N J N 03 a) o r o 00 co LL a I— U 0 • Ce 0. IC w L J La a (,D 4 X w Z Q In III 1 �C]w U w 9 (/ 2 (f) (n [� < Q 0 I- DATE 04/18/2008 BJD BJD JTP MECHANICAL DETAILS SPLIT DX AIR HANDLING UNIT WITH CONDENSING UNIT RESPONSIBILITY SCHEDULE ITEM FURNISHED BY INSTALLED OR PERFORMED BY RE -USE N/A REMARKS ESD&C VENDOR LANDLORD CONTR. LANDLORD CONTR. OTHER EXISTING AIR HANDLING UNIT AC MC Of Trarran.ciran MC LI G t' MC TO HIRE LANDLORD APPROVED ROOFING CONTRACTOR AIR HANDLING UNIT DISCONNECT/ FAN CONTACTOR AC 430 t= 2 0700 94A1 t* AC bfr 0 HIGH AND LOW PRESSURE SWITCHES (FACTORY INSTALLED) AC b MC Ski i ht Trarsrrission CI t= AC Door Loads FACTORY INSTALLED ELECTRIC HEATER WITH SINGLE POINT CONNECTION AND CONTACTOR AC d t' LI _ MC 0 4730 t: 0 • 04:30 t= ADAIPTER BOX WITH ACTUATOR AND 0 -10 VOLT AC Parttiorl_ U t= G MC Lr t' 4 - INTERCONNECTIVE WIRING BY MC HOT WATER COIL 0 - 0 1' 0 CI - Ova Lighting :.972 'UV • - THERMAL EXPANSION VALVE AC 1152 tiff gfg0;2 MC a - Eleotri:: G Jiprnerrt f C><a:3 U.l BAS CONTROLLER AC ii 0 _ People AC 16:340 2041) 0 SUPPLY AIR TEMPERATURE SENSOR AC I Cittration u 0 AC r1: h r. x11- SPACE TEMPERATURE SENSOR AC :5070 - D MC Sakty Factor 10 /1LI 11710 2: CARBON DIOXIDE SENSOR AC U .- TEL .A L x1 MC Z11?:: 13. CONDENSATE PAN OVERFLOW SWITCH AC 1I:I:1: ::::0 29:17 - 21104 AC Plenum Wall Load LI I p FAN PROOVING SWITCH AC U - Plenram Roof [Dad 01 AC 0 0 HOT WATER VALVE WITH ACTUATOR Pl.rrurn Ughtira Load 0 :. 0 0 0 - 5 00011 CFiu1 VIBRATION ISOLATORS AC 80E0 CFM 0 MC 2 2FS.x, DF1u1 08 04 -134-12 221 C FTv1 AIR COOLED CONDENSING UNIT AC eupplti »'Fan Load S ace Fan C 1Fars 2000 C:FNA 0 0 MC 80CL11 CH,' 0 - 13uct Heat Gain f Low CONDENSING UNIT DISCONNECT SWITCH 0 - EC U EC >P Tot4 Sim-tern Lc :: CONDENSING UNIT GROUND FAULT OUTLET EC EC 12410 b b OUTSIDE AIR TEMPERATURE SENSOR AC - ti1. 7 2 - MC v:. T ot -4 Ccrldt cna11"eI ONE PER PROJECT LOW AMBIENT KIT AC 1` :'SLS n Ney MC Posit »e'1alu•.-' are l b_,n± F.-- tidewalue:,arer,IaIi:.± FINAL CONN. BY MC SPLIT SYSTEM COMMISSIONING AC MC MC AC LL HVACCSUPPUER HVAC RESPONSIBILITY SCHEDULE ITEM r) III. ;1x I"I EA 11' INSTALLED OR PERFORMED BY r :oC LING 11A,TH AT Jun 1 ::00 CODLING OA DE,fVVvE: M.0 °FfG41,4 °F HEATING DATA AT CD I-ITG HEATING OP. DE2AND 23i) IT f10 9 ZONE LUP.D1 VIlydou) •_ Sln{IiOfrt Soles Loads Details 0 V 9 -reside. (BTLI.hr) ... Lbtert (BT Whir ) a ttil_ er1.itoe (13T1_1 Lest =rt (BTLOT] 0 ROOFING CUT & PATCH, INSULATED TOE KICK & CURB LEVELING. 0 t3 MC Of Trarran.ciran 4 f= LI G t' MC TO HIRE LANDLORD APPROVED ROOFING CONTRACTOR DUCT SMOKE DETECTOR Ft acif Tres n=rri icrl 'rLIirdou)Trarrsrriz on 430 t= 2 0700 94A1 t* 10251 bfr 0 SMOKE SYSTEM ACCESSORIES, ETC, G it' 0 tx b MC Ski i ht Trarsrrission CI t= 0 Door Loads U t= 0 - d t' LI _ FI Trare rri soon 0 4730 t: 0 • 04:30 t= b - Parttiorl_ U t= G - Lr t' 4 - CelirrJ Cl t= 0 - 0 1' 0 CI - Ova Lighting :.972 'UV 11102 - 0 T a - Light rig 1152 tiff gfg0;2 G a - Eleotri:: G Jiprnerrt f C><a:3 U.l 1 &024 _ ii 0 _ People 102 16:340 2041) 0 0 0 I Cittration u 0 r1: h r. x11- DUCT SUPPORTS 3[1170 :5070 - D D Sakty Factor 10 /1LI 11710 2: 10 1025 U .- TEL .A L x1 12 111 i; Z11?:: 13. Zone Conditr.irring 1I:I:1: ::::0 29:17 - 21104 4 Plenum Wall Load LI I p TOILET EXHAUST FAN(S) WITH TOGGLE DISCONNECT SWITCH 0 U - Plenram Roof [Dad 01 0 0 T OILET EXHAUST DUCTWORK WALL OR ROOF Pl.rrurn Ughtira Load 0 :. 0 0 0 - Relrrr Fan Load 00011 CFiu1 0 - 80E0 CFM 0 '� errtil I ' n Load 2 2FS.x, DF1u1 08 04 -134-12 221 C FTv1 112701 0 eupplti »'Fan Load S ace Fan C 1Fars 2000 C:FNA 0 0 • 80CL11 CH,' 0 - 13uct Heat Gain f Low 01 0 - et U >P Tot4 Sim-tern Lc :: . Cenral Coolin0 Coil 175:363 12410 b b Centrall42atn Lxril AC - ti1. 7 2 - 1U5 v:. T ot -4 Ccrldt cna11"eI 1 x 12410 AC 1` :'SLS n Ney Po3itive ValLes. e clg I ina, Negative in' ues al loals Posit »e'1alu•.-' are l b_,n± F.-- tidewalue:,arer,IaIi:.± HVAC RESPONSIBILITY SCHEDULE ITEM FURNISHED BY INSTALLED OR PERFORMED BY RE-USE N/A REMARKS ESD&C VENDOR LANDLORD CONTR. LANDLORD CONTR. OTHER EXISTING ROOFING CUT & PATCH, INSULATED TOE KICK & CURB LEVELING. MC NC MC TO HIRE LANDLORD APPROVED ROOFING CONTRACTOR DUCT SMOKE DETECTOR FAC MC IF NO FIRE ALARM SYSTEM, FURNISHED AND INSTALLED BY AC SMOKE SYSTEM ACCESSORIES, ETC, MC MC UNLESS FACTORY INSTALLED DIFFUSERS AND GRILLES LD MC DIFFUSERS /GRILLES FIRE DAMPERS • WALL FIRE DAMPERS S COMBINATION FIRE /SMOKE DAMPERS • LOW PRESSURE DUCTWORK MC MC HIGH /MEDIUM PRESSURE DUCTWORK DUCT SUPPORTS MC MC SEISMIC BRACING S DUCT HEATER(S) • TOILET EXHAUST FAN(S) WITH TOGGLE DISCONNECT SWITCH LD MC T OILET EXHAUST DUCTWORK WALL OR ROOF MC MC PIPING AND PIPING APPURTENANCES (CIRCUIT SETTERS, ETC.) • BALANCE CONTRACTOR REPORT MC AABG OR NEBB CERTIFIED AS -BUILT DRAWINGS MC LANDLORD CONTROL SYSTEM MC MC TEMPERATURE CONTROL SYSTEM COMPONENTS AC MC TEMPERATURE CONTROL SYSTEM WIRE AC MC FINAL CONN. BY MC LOCKING QUADRANT VOLUME DAMPER MC MC PNEUMATIC TUBING 5 FIRE ALARM SHUTDOWN RELAY FAC FAC WHERE APPLICABLE FOR FIRE ALARM SYSTEMS REUEF AIR DAMPER MC MC REUEF AIR FAN OR RETURN AIR FAN • SMOKE EVACUATION 5 OUTSIDE AIR INTAKE HOOD /LOUVER WITH DAMPER MC MC OUTSIDE AIR INTAKE DAMPER ACTUATOR MC MC REUEF AIR HOOD OR LOUVER WITH COUNTER- BALANCED BACKDRAFT DAMPER MC MC ECONOMIZER DAMPER MC MC RECEIVED ECONOMIZER DAMPER ACTUATOR AC MC Atli 2 9 1008 OUTSIDE AIR DAMPER MC MC PERMI CENTER OUTSIDE AIR DAMPER ACTUATOR AC MC its N arne „ ,.,, „,,,.. Lecatir , ............... ............................... Latitude Longitude ._.... El wuati iirr ,,....., .......... ......,,,..,,......,.,,.,,...., Burn rrrFr L Urv.Du . ........................ S urn rher Coincident Gulf; .................. Sum rhe bal ts• F: rije ............................... TPY into r ign Dry - @'SIG ... . ....................... 1.01int. r ['. ign 'diet - lb ......... ..... AtmrJc p FIe rio C I& a rn N urn be r .... . ......... Aver a'e (. rrrurid F: eflerA arr� ,....,....,,..,... rail C rlduc rviF{ ..... Loral Timia Zanp (GMT -+ %- FI hours) ..____.. Crrgid.ar Uzi IijFrt TinE .............. Simulation ''le alb er Bata ........... ...... r rlrrerIf D ata is __...... D I:;)cling lrltl' ............................ � t m 'v r r a Irif ': rrc) t i n fidr S',eta!! rre. ... 'WE STFIELD 8 OUT HCEhlrERt1 E IJiprro.rrt Cb . ! PLTAHU fir S;f-tK i T'pg' . 2 D IZir3;g CCIcr..111ati' :tt Irf rrrr iorn . a ct S zj r Mel t� ne CFTui ....... ............... :��rn nI spere al rt low rates pa; C F 1 1 , 4 , , , , , , , , , , , , , , , , , , Inci',r dual Fpak Icy -- Cer-rtr z-1 Cool INC it Sizing 0 a Tod oDil load ..- 115. To-ti xiII ..- 107 Senable toil load . 1711 tl D:'iI C :F1v1 atJla 130G ........ .. . ........ ,,,,......,.,......,.,. 7844 luta Nod( CFTui ........................ 800n sum of ryna kzone ORA .......... Bibb SenOble flat ratir, 0.3311 !L:rorr 533/ �IUaterll e 1U,G °Frise Centr I- leafing Coil Lazing Dzitn tuba coil load ..... . 1.332 lid BH Coil C Fim at [h 1 ........... ............... .....,......,... Z.357 CFt11 I'Jti pail CFt 1 _......... 657 r"..*- ETA rig erlow ic!20.0 °F ddrrap .................................... L`J!A GLAD; Iy Fsn Grata Tons E 6H 011 OH FTl1 C: Flij1 Ij RA J'cfi aIrnax CPO .. E000 Is Standard C :FNI ................... 707•l C:FtJi .actua ,,,,,,,,,,,,,,,,,,, ,,,,,,.4,35 C: Miff o+sb:ir :roc VP_ ntiiat iorI Air Data De i.n airt a!V I=:Ftr,1 ............. ....................,.......,., 22 OF/11 C 'FP. tg ................................. ............................... 0,27 C- Ft.1.1' DESIGN WEATHER PARAMETERS ,,,,,,,,,,,,,,,,,,,,,, ,,,,,, „ „, „.,. „,,,, „,.,,,, „,,,.. rattle LAP 'Olszhirr!t on be 0. 122_:3 Den. 44 -'.'J ft :IF. ID °F 03.0 °F HVAC LOAD CALCULATIONS n, 2rJ 11.3 °F ;x'•.11] °F D. Gn BTUA;hr- tt - °F) fa hours I -I o no net-11.4 2OJ 1 "_:HR1 E Handbook J rra�y rr ier tiffntierr+fzones ._.._._.... .0 Flr1�r1'rea ........................... ................. ......... Lr . ... ... .. .. ........................ Seattle ... . LA,F,V'." ;fir borr iU1uIatr. n hJlorths Jan to ri2o aizirr Dab ,,,,,,,,,,,,,,, ,,,,,,,,,,,, I trladrfiEd LoadG ciiJrs at ........ . . ........ ............................... Jlsi 1 :300 OA DH!'Illlb ......................... ........................_.:3'2.0 104.4 Ent ig DB .r'UUfi ._..........- .--- ........._......_._._._._. 773.0 /64..7 L6a.ir GEl .r Pre ,....,..,,,,. ,... .. ......................... .11 , 4 1.1 6 6 �r r CciIADP ........ .......................... ............__._._._......._._. 55.7 01,p ass Factor .... ..................... ............................... 0100 Resulting ....._ ......................... ._._...._._._._._....._._._._._ 50 Design elJ p pl'rternp . 5G 0 'rr =Titrt C fp -M. Prof 6 Nlay. n terrperatu re d_ . ............................... 12 ° F OF °F ° F °F ra K Load a or lrs at ....... ............. ............................... Des Htr1 BT! 11 Ir -115 ...... ................ ....................,,,.,.,.,.. ..,. 153 Er it. GB r QEr ....,.,•,,, ,,.,... ............... 110 °F Farr ....... .................. ............................... 0.00 EHP Fan rrr i ' r Ilia Ii rj f b k'i!1! CFriA' purz cfr ............................ ............................... 222'1 C'Fhl1pers HVAC LOAD CALCULATIONS NTS OODMO4IJOLOAD NOTES: SET POINTS: SPLIT DX AIR HANDLING UNIT WITH ELECTRIC HEAT NETWORK WIRING AND SEQUENCE OCCUPIED HEATING: 70•F COOLING: 74'F UNOCCUPIED HEATING: 60'F COOLING: 857 1813 CABLE I BENBORIS)! 22/2 COMMUNICATION CABLE COMMUNICATION FRONT END 1 I TERMINATE NETWORK WIRES ON THE LIGHTING CONTROLLER NETWORK TERMINALS LOCATED IN THE IFS I ELECTRICAL PANEL SYSTEM. ACCU -1 AHU -1 22/2 COMMUNICATION CABLE 18/3 CABLE ZONE CO2 SENSOR SENSOR (1) ALL WIRE SHALL BE 18/3 UNLESS OTHERWISE INDICATED. (2) NUMBER OF CABLES FURNISHED BY HVAC MANUFACTURER IS INDICATED BY NUMBER OF TICK MARKS ACROSS THE LINE. (3) PURPLE 22/2 WIRE IS PROVIDE BY HVAC SUPPLIER AND IS PLENUM RATED. (4) SCHEMATIC IS FOR REFERENCE ONLY. AT TIME OF CONSTRUCTION, THE HVAC SUPPLIER WILL PROVIDE A COMPLETE DIAGRAM FOR INSTALLATION. SEE RESPONSIBILITY SCHEDULES, THIS SHEET, FOR A LIST OF ALL COMPONENTS AND SENSORS REQUIRING FIELD INSTALLATION. SPLIT DX AIR HANDLING UNIT (AHU) SEQUENCE OF OPERATIONS MANUFACTURER SHALL FURNISH AND /OR INSTALL ALL NECESSARY CONTROL DEVICES TO ACCOMPLISH THE FOLLOWING SEQUENCE OF OPERATION (REFER TO RESPONSIBILITY SCHEDULE FOR FIELD INSTALLATION REQUIREMENTS): DURING OCCUPIED HOURS THE SUPPLY FANS SHALL OPERATE CONTINUOUSLY, AND THE OUTSIDE AIR DAMPER SHALL OPEN TO THE MINIMUM SCHEDULED POSITION (ADJUSTABLE). WHEN THE OUTDOOR TEMPERATURE IS ABOVE 55 DEGREES FAHRENHEIT (ADJUSTABLE), AND THE SPACE TEMPERATURE IS 1'F ABOVE COOLING SET POINT, COOLING SHALL BE ENERGIZED IN STAGES (WHERE APPLICABLE) UNTIL 1'F BELOW SET POINT IS ACHIEVED. WHEN THE OUTDOOR TEMPERATURE IS BELOW 55 DEGREES FAHRENHEIT (ADJUSTABLE), AND SPACE TEMPERATURE IS ABOVE COOLING SET POINT, COOLING SHALL DEENERGIZE, AND OUTSIDE AIR DAMPERS AND RETURN AIR DAMPERS SHALL MODULATE TO PROVIDE A SUPPLY AIR TEMPERATURE TO SATISFY THE DEMAND FOR COOLING. IF THE SPACE TEMPERATURE FALLS 1'F BELOW THE HEATING SET POINT, AND THE OUTDOOR DAMPER IS AT THE MINIMUM POSITION, ELECTRIC HEAT SHALL BE ENERGIZED IN STAGES (WHERE APPLICABLE) UNTIL 17 ABOVE SET POINT IS ACHIEVED. DURING UNOCCUPIED HOURS, THE SUPPLY FANS SHALL DEENERGIZE AND THE OUTDOOR DAMPER SHALL CLOSE. IF THE SPACE TEMPERATURE RISES 1'F ABOVE THE COOLING SET POINT, THE FANS SHALL ENERGIZE, AND THE OUTSIDE AIR DAMPERS SHALL REMAIN CLOSED. COOLING SHALL BE ENERGIZED IN STAGES (WHERE APPLICABLE). WHEN THE SPACE TEMPERATURE FALLS BELOW COOLING SET POINT, COOLING AND FANS SHALL DEENERGIZE. IF THE SPACE TEMPERATURE FALLS BELOW THE HEATING SET POINT, THE FANS SHALL ENERGIZE, AND THE OUTSIDE AIR DAMPERS SHALL REMAIN CLOSED. ELECTRIC HEAT SHALL BE ENERGIZED IN STAGES (WHERE APPLICABLE). WHEN THE SPACE TEMPERATURE RISES ABOVE THE HEATING SET POINT, ELECTRIC HEAT AND FANS SHALL BE DEENERGIZED. THE RELIEF SHALL HAVE A GRAVITY RELIEF DAMPER WHICH WILL KEEP THE PRESSURE IN THE SPACE FROM BUILDING UP. MANUFACTURER PROVIDED PAN OVERFLOW SWITCH WILL DISABLE ALL FANS, COOLING, HEATING, AND CLOSE OUTDOOR AIR DAMPER IF HIGH WATER IS SENSED IN THE PAN. A FIELD INSTALLED CO2 SENSOR SHALL MODULATE THE OUTDOOR AIR DAMPER CLOSED DURING OCCUPIED OPERATION FROM SCHEDULED CFM TO CODE ALLOWED MINIMUM, FROM CO2 OF 1000PPM TO 500PPM. A DUCT MOUNTED SMOKE DETECTOR SHALL DEENERGIZE THE SUPPLY AND RELIEF FAN, AND CLOSE THE OUTDOOR AIR DAMPER WHEN ACTIVATED. NOTE TO CONTRACTOR ITEM(S) NOT SHOWN ON ANY OF THE RESPONSIBILITY SCHEDULES ARE THE RESPONSIBILITY OF THE CONTRACTOR. LOCAL AREA REQUIREMENTS YES NO 1. SMOKE EVACUATION 2. CARBON DIOXIDE MONITORING 3. HURRICANE ZONE 4. SEISMIC ZONE YES NO El El ❑ 5. SPECIAL CURB HEIGHT REQUIREMENTS 6. FIVE MILE COASTAL PROXIMITY 7. OTHERS, I.E. METHANE, CARBON MONOXIDE, SOUND SENSITIVE, ETC. DESCRIPTION. . ABBREVIATIONS, RESPONSIBILITY SCHEDULES AC AHJ BAS EC FAC HVAC EQUIPMENT SUPPLIER AUTHORITY HAVING JURISDICTION BUILDING AUTOMATION SYSTEM ELECTRICAL CONTRACTOR FIRE ALARM CONTRACTOR \r), GC GENERAL CONTRACTOR LC LANDLORD CONTRACTOR LO LIGHTING PACKAGE DISTRIBUTOR LL LANDLORD ESD&C EXPRESS STORE DESIGN & CONSTRUCTION MC MECHANICAL CONTRACTOR CODE COMPLIANCE AP PROVED MAY - 8 200 City Of Tuksiiiiii-C BUILDING' ':,IVISIGN MECHANICAL RESPONSIBILITY SCHEDULES, NETWORK WIRING AND SEQUENCE NTS OODM041A4SCHD SHREMSHOCK 6130 S. WESTERVI 614-545 0 D x w 0 � LEI ' INDICATES NO REVISION TO THIS SHEET DATE ISSUED: DESIGNED BY: DRAWN BY: CHECKED BY: GINEERING, INC, AD fit" z 0 I0. W I- co 0 CO cc ,....,, 1c II >C cu LUI � w � J u G a W eWt`�L J m=i�� ... r z �W = ow ~ W Z ;w�w ct W C IT: 6 4 W� ` � O w o z WE :U 0 p w U W W� W O w L U .-W wJ w � v ° - ii © !!!!! 22 In F-- o 4 U N - cn F-�- W z �Q �= Y ("7 d O O r W U V l O x F- c�j NCa .q N x � ' iii w )E ‘.0E Z 0f W X Z Zw C LI- aI -UU_f� w Q o. J W H IJ.I•aC¢ CL D Lt REVISIONS: 00 00 00 t0) REQUITED BY: DATE 04/18/2008 BJD BJD JTP MECHANICAL RESPONSIBILITY, SCHEDULES DRAWING NUMBER: 4.1 N D CO O7 0 00cO 0_ 0 © CO 0 n • 0 2 � C? I- U Lu 0 C3 I- 0 W Z U a - oti C3 tl1 0 (fl W