HomeMy WebLinkAboutPermit M08-125 - WESTFIELD SOUTHCENTER MALL - OAKLEYOAKLEY 556 SOUTHCENTER MALL M08-125 Parcel No.: 6364200010 Address: Suite No: Tenant: Name: OAKLEY Address: 556 SOUTHCENTER MALL , TUKWILA WA Owner: Name: Address: Contact Person: Name: ELIZABETH VALERIO Address: 5858 WILSHIRE BL, #203 , LOS ANGELES CA Contractor: Name: LAKEVIEW CONSTRUCTION INC Address: PO BOX 308 , PLEASANT PRAIRIE, WI Contractor License No: LAKEVCI072KC DESCRIPTION OF WORK: INSTALL NEW MECHANICAL DUCT SYSTEM IN AN EXISTING RETAIL STORE. Value of Mechanical: $5,000.00 Type of Fire Protection: SPRINKLERS /AFA Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC-10/06 Citylif Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us 556 SOUTHCENTER MALL TUKW WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD CA MECHANICAL PERMIT EQUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 0 0 0 0 0 0 0 0 * *continued on next page ** M08 -125 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 323 - 954 -8996 Phone: 414 657 -4222 Expiration Date: 01/13/2009 M08 -125 06/09/2008 12/06/2008 Fees Collected: $226.13 International Mechanical Code Edition: 2006 Boiler Compressor: 0-3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP/ 1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 06 -09 -2008 Permit Center Authorized Signature: doc: IMC -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: M08 -125 Issue Date: 06/09/2008 Permit Expires On: 12/06/2008 Date: 676' /09/0 l� V I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not p -s e to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perfo ce of authorized to sign and obtain this mechanical permit. Signature: Date: — � Print Name: I . � tA A. V ' V e C This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M08 -125 Printed: 06-09 -2008 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • City of Tukwila Parcel No.: 6364200010 Address: 556 SOUTHCENTER MALL TUKW Suite No: Tenant: OAKLEY Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: M08 - 125 Status: ISSUED Applied Date: 04/30/2008 Issue Date: 06/09/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: ** *FIRE DEPARTMENT CONDITIONS * ** 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 13: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 14: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 15: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) doc: Cond -10/06 M08 -125 Printed: 06-09 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 17: All new fire alarm systems or modifications to existing systems shall have the written approval of The Thkwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 18: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 19: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 20: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 21: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond - 10/06 * *continued on next page ** M08 -125 Printed: 06-09 -2008 Signature: Print Name: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. doc: Cond -10/06 M08 -125 Date: 4----oe ordinances governing or local laws regulating Printed: 06-09 -2008 CITY OF TUKWIL• Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hup: "i.v ww. ci. tzikwila tiro. us SITE LOCATION Site Address: Tenant Name: Oak( 1. Property Owners Name: b> S4 F']UG ,p Mailing Address: I b (> ( W .c i Y' - \ v( E -Mail Address: Company Name: Mailing Address: Contact Person:3 -0-1/1 E -Mail Address: Vo leiro ,Ay I ic,teci. 556 coLto Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** 61410 1 Can . e,6144 Q1Applications\rorms- Applications On Line0-2006 - Permit Application.doc Revised: 9 -2006 bh Building Permit No. pop), '-`� -- Mechanical Permit No >.:. ,IA. O -' I Z Plumbing /Gas Permit NO.- ..( Public Works Penn t No: (f� Project No 2�'" (For office useonip) King Co Assessor's Tax No.: Suite Number: Floor: New Tenant: Yes ❑..No Cit State State State et (212,c Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name: 11 ( (:i'l Vl,� I lv r Day ) Telephone: .62.3 -- / •�`r t ( Y/0/ 4:;- 5 ) Mailing Address: j � ) [ 1 ? , i/ ye./ - #��� L-9- , ?' ' City State / Zip E -Mail Address: eV i leric) I/c.ifoOeweju Fax Number: 7 3-9521- V6 GENERAL CONTRACTOR INFORMATION ' (Contractor. Information for. Mechanical (pg 4) .for Plumbing.and Gas Piping (pg 5))' Company Name: 1-6D T, Mailing Address: Zip City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: ARCHITECT . OF RECORD. - All plans must be wet stamped by Architect of Record Company Name: 77 ,( Mailing Address: ` �j ( s/ �G( e . /, yc. ' C gy � pp ,,R C � 2 O3 1 L-4- / p ,, City St �e � Zi - p Contact Person: i1 I &A-.). 7( f Vet C D Day 523 -79/ ,-' 1 - �5 / � X / • '[f ax Num �� ?j_ f /_ 76 ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record -7 Zip n Day Telephone: "1 / 6- / .7) - g / y (7 Fax Number: q - 77.2 ' -/ . l Page I of 6 BUILDING PERMIT INFO. ION'- 206 - 431 -3670 Valuation of Project (contractor's bid price): $ Scope of Wojk (please provide detailed information): .t71 Will there be new rack storage? FIRE PROTEC ON /HAZARDOUS MATERIALS: Sprinklers Yes Q.\Applications \Forms-Applications On Line \3 -2006 - Permit Application doc Revised' 9 -2006 bh Automatic Fire Alarm t;1c_ fras Existing Building Valuation: $ /j/74 3` Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck Provide All Building Areas in Square Footage Below Interior Remodel Addition to Existing Structure Type of Construction per IBC" Type of Occupancy per IBC PLANNING DIVISION: ` ` Single family building footprint of th oundation of all structures, plus any decks over 18 inches an - rhangs greater than 18 inches) *For an Accessory dwelling, provide th ollowing: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: D.. No If yes, a separate permit and plan submi• : I will be required. *Provide documentation t.. shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Pro ' . ed: Standard: Compact: Handicap: Will there be a change in ? ❑ Yes ❑ No If "yes ", explain: ❑ None ❑ Other (specify) Will there be storage or use of flamma 3le, combustible or hazardous materials in the building? ❑ Yes If "yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety"Data Sheets. SEPTIC SYSTEM ❑ On -site pti System – For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. No Page 2 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: 0 -3 HP /100,000 BTU Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper Furnace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended /Wall /Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig /Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm /Ind MECHANICAL PERMIT INFWIVIATION — 206 - 431 -3670 MECHANICAL CONTRAS OR INFORMATION Company Name: /( t \ J Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $ Scope of Work (please provide detailed information): s y , l" cep . Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New Replacement .... ❑ Fuel Type: Electric.. Gas ....0 Other: Indicate type of mechanical work being installed and the quantity below: Q \Applications\Forms- Applications On Line\3 -2006 - Permit Application doc Revised 9 -2006 bh Page 4 of 6 PUBLIC WORKS PERMIT IN RIVIATION — 206-433-0170 Scope of Work (please provide detailed information): P 1 Water District ❑ ...Tukwila ❑ ...Water Availability Pro 'd Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate FINANCE INFOR ION Water Meter Refund/Billing: Name: Mailing Address: Call before you Dig: 1- 800 - 424 -5555 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Submitted with Application (mark boxes hich apply): ❑ ...Civil Plans (Maximum Paper Size —2 ❑ ...Technical Information Report (Storm Dra ❑ ...Bond ❑ .. Insurance Proposed Activities (mark boxes that apply): ❑ ...Right - of - way Use - Nonprofit for less than 72 hou ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way ❑ ...Total Cut ❑ ...Total Fill ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ .. ❑ ...Fronta Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic 'ater Q'Wpplications\Forms- Applications On Linea -2006 - Permit Application, dot Revised 9 -2006 bh 0... Water District #125 ❑ .. Highline ... ValVue ❑ .. Renton ..Sewer Availability Provided Septic System: ❑ On -site Septic System — For on -site eptic system, provide 2 copies of a current septic design cubic yards cubic yards 34 ") ge) ❑ .. Geotechnical port ❑...Traffic Impact Analysis Easement(s) ❑ .. Maintenan Agreement(s) ❑...Hold Harm ess — (SAO) ❑...Hold Harm ess — (ROW) ❑ .. A don Septic T rb Cut . Pavement Cut .. Looped Fire Line Fire Line Size at Pro erty Line ❑ ...Water ❑ ...Sewer ❑ ... Sewa Treatment Monthly Service Billing to: Name: ❑ .. Renton ❑ .. Seatt ❑ ht-of-way Use - Profit for less than 72 hours ight -of -way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergroundin ❑ ...Permanent Water Meter Size . WO # ❑ ...Temporary Water Meter S' - .. WO # ❑ ...Water Only Meter Size. WO # ❑...De+' ct Water Meter Size ❑ ...Sewer Main Extensio Public Private ❑ ...Water Main Extensi • Public Private Number of Public Fire Hydrant(s) City City State roved by King County ealth Department. Day Telephone: Mailing Address: Zip Day Telephone: State Zip Page 3 of 6 PERMIT APPLICATION NOTES - Applicable to all permits in this ap Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. State Zip BUILDING OWN y 0 : AUTHORIZED AGENT: Signature: Print Name: Mailing Address: Date Application Expires: g73 OE Date Application Accepted; 4 -5v- -o Q \Applications \Forms - Applications On Line \3-2006 - Permit Application doc Revised 9 -2006 bh Day Telephone: Date: / ido Staff Initials: Page 6 of 6 Fixture Type: 'Qty Fixture Type: .. "Qty Flattdre'T.y °' Qty ; ' Fatiare'Type: : Qty Bathtub or combination bath/shower Drinking fountain or er cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grind , commercial Receptor, indirect ante Clothes washer, domestic Floor drain ks Dental unit, cuspidor Shower, si le head trap Ur Is Dishwasher, domestic, with independent drain Lavato Wate Closet Building sewer or trailer park sewer Rai water system — per in (inside building) Water he r and /or vent Additional medical gas inlets /outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors epair or alteration of water piping and/or water treating equipment Repair or alte on of drainage or ye piping Medical gas piping system serving one to five inlets /outlets for specific gas PLUMBING AND GAS PIPIN RMIT INFORMATION — 206 - 431 - 3670.. , • PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Plumbing ork (contractor's bid price): $ (, add - d a Valuation of Gas Piping ark (contractor's bid price): $ Scope of Work (please prow. - detailed information): dr /1 4.5" Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping out 139 o. Applications\Forms- Appbcations On Line13 -2006 - Permit Application.doc Revised: 9 -2006 bh mg installed and the quantity below: Page 5 of 6 Payee: LAKEVIEW CONSTRUCTION INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 224236 180.90 ACCOUNT ITEM LIST: Description MECHANICAL - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: M08 -125 Address: 556 SOUTHCENTER MALL TUICW Status: APPROVED Suite No: Applied Date: 04/30/2008 Applicant: OAKLEY Issue Date: Receipt No.: R08 -02015 Payment Amount: $180.90 Initials: LAW Payment Date: 06/09/2008 10:43 AM User ID: 1632 Balance: $0.00 Account Code Current Pmts 000.322.102.00.0 180.90 Total: $180.90 3446 06/09 9711 TOTAL 180.90 doc: Receiot -06 Printed: 06 -09 -2008 RECEIPT NO: R08 -01417 Initials: BLH User ID: ADMIN Payee: EXPRESS PERMITS SET ID: S000001018 SET TRANSACTIONS: Set Member D08 -242 EL08 -495 M08 -125 PG08 -141 TOTAL: TRANSACTION LIST: Type Method Payment Check ACCOUNT ITEM LIST: Description City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Amount 1,293.50 100.00 45.23 23.00 1,293.50 Description Amount 11553 ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES SET RECEIPT TOTAL: Payment Date: 04/30/2008 Total Payment: 1,461.73 SET NAME: Tmp set/Initialized Activities 1,461.73 1,461.73 Account Code Current Pmts 000.345.832.00.0 100.00 000/345.830 1,361.73 TOTAL: 1,461.73 1$i 04/30 9711 TOTAL 1461.73 Steven M. Mullet, Mayor Steve Lancaster, Director Project: 6 AI4LE1 Type of Inspection: rIINIA t '-:-' Address: 11 5 349 IM A Date Called: Special Instructions: Date Wanted: - 7- z 3 - Off'? a.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION '- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 '2 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: �° ✓ w l "cZw\ P l el API I Date: 7- 2g —O % 17 $4' 0 REINSPECTION FEEQUIRF,9. Prior to inspection, fee must be pa . at 6300 Southcenter B Suite 100. Call to schedule reinspection. 1 Receij No.: 'Date: Project: O Tye of Inspection: Address: J ;4 10 in I -L Date Called: Special Instructions: Date Wanted: - 7 i iq /VC a.m. p.m. Requester: Phone No: INSPECTION NO. INSPECTION RECORD Retain a copy with permit �1a�s -,2 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ® Approved per applicable codes. Corrections required prior to approval. COMMENTS: VAV ' , �l.R i- 4 w J 14,064vIS S I'o . 3 1 PGtX - ad . $12-1,04. S. I frt L IL I? Date: 7 1 of 103 - $60.00 REINSPECTION FEE EOUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspecto (Receipt No.: Date: Project: I e Type of Inspection: .�� .moo Address: SSC� / / Date Called: Special Instructions: Date Wanted: ? / a.m p.m. Requester: Phone No: 33(_ gag 21tD p INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION • 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ❑ $60.9 R4INSPECTION FEE REQUIRED. Prior to inspection, fee must be pai t 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (206)431 -3670 °Approved per applicable codes. Corrections required prior to approval. COMMENTS: VWU ,it: &j /t'd/ ai,d e ai o ha a.S 4? tl ce,1 taw fl (Receipt No.: 'Date: / Project:0,k f Type of Inspections � Address: ' 5 Aled/ Date Called: Special Instructions: Date Wanted: �� Dr a.m. p.m. Requester: Phone No: z INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3(x0 El Approved per applicable codes. O Corrections required prior to approval. COMMENTS: e/ 0 I Voir ej, co ✓ce " 5-014.25 are& Inspector: 1.43 Date: 7 4/ El $60. EINSPECTION FEE REQUIRED. Prior to inspection, fee must be paint t 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: ' Project: ,,,gg I:Ji Type(� , l�-At9 h- 7N Address: nel 14- t 5; Date Called: Special Instructions: s Date Wanted 2 — Q r p.m. Reque - Vfer: Phone No: 3lCo ed3_ZI1C) 1 INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367 Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: 19A PIC 1 - 74311d 1n 5eie.$ -reu. Inspector: Date: / VO n $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: � . COMMENTS: 1_4•\., . •••■••......, • •... r.........._ Ty • e of Inspection: .-4,.,;•0 4 79 / /\ c < )0 e --'e \ -C I - Fr.) Or L — S . C , Iv l /; / _ L _ Contact Person: ' Pre -Fire: IJ Special Instrucctions: te -j; Permits: N Phone No.: /tee' 35 A -- 0 K . 9/ V/ - r - r - f Al 11JVYG, 1 11, n Project: 15 f\I;(4../.4 1_4•\., . •••■••......, • •... r.........._ Ty • e of Inspection: .-4,.,;•0 4 79 / /\ c < )0 e --'e \ -C I - Address: S75-4 Suite #: S . C , Iv l /; / _ L _ Contact Person: ' Pre -Fire: IJ Special Instrucctions: te -j; Permits: N Phone No.: Needs Shift Inspection: Y Sprinklers: y Fire Alarm: ice' Hood & Duct: 0 Monitor: 6. f,r) Pre -Fire: IJ ti te -j; Permits: N Occupancy Type: w■. INSPECTION NUMBER Approved per applicable codes. CITY OF TUKWILA FIRE DEPARTMENT INSPECTION RECORD -Retain a copy with permit Word/Inspection Record Form.Doc 1/13/06 r rv1 o 4r - tl y ~ Y PERMIT NUMBERS 206 -575 -4407 Corrections required prior to approval. Inspector: Sl Date: 7//7/ Hrs.: 1 f $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the e City of Tukwila Finance Department. CaII to schedule a reinspection. p T.F.D. Form F.P. 113 Cooling Equipment Schedule , ...-. Equip. Brand Name' Model No. Capacity2 Btu/h Total CFM OSA CFM or Econo? SEER R or EER aribE 4-6 � VAV-1 Titus ATQP -03 -12 n/a 1530 n/a n/a /a ODIMP g Applicant Address: �p One Icon, Foothill Ranch, CA 92610 Applicant Phone: (949) 639 -1136 PI r'0 1 ,14(1 I . MA -8 ,, lIESTNIMM Z7Li7T_� 11111!!! ) i. r _ i i Heating Equipment Schedule Equip. ID Brand Name Model No. Capacity2 Btu/h Total CFM OSA cfrn or Econo? Input Btuh Output Btuh Efficiencv VAV -1 Titus ATQP -03 -12 n/a 1530 n/a n/a n/a stockroom F!ECE g ED !OM AM 3.0 PERMIT CENTD Fan Equipment Schedule Equip. ID Brand Name Model No.1 CFM SP HP/BHP Flow Control Location of Service VAV -1 Titus ATQP -03 -12 1530 0.5" 0.25 VAV Entire store g Applicant Address: �p One Icon, Foothill Ranch, CA 92610 Applicant Phone: (949) 639 -1136 PI r'0 1 ,14(1 Project Info Project Address 556 Southcenter mall Date 4/25/2008 Tukwila, WA 98188 For Building Dept. Use 1 IT Applicant Name: Oakley g Applicant Address: �p One Icon, Foothill Ranch, CA 92610 Applicant Phone: (949) 639 -1136 PI r'0 1 ,14(1 11. ,. 1 •• •• Mechanical Summary ■•I - • . •- • ••- •u. <• • u MECH -SUM 2006 Washington State Nonresidential Energy Code Compliance Forms Project Description Briefly describe mechanical system type and features. ® Includes Plans Mechanical system is mall - provided chilled supply air, with tenant - provided single parallel fan - powered VAV box with electric heating;"`y controlled by one thermostat in tenant space. Drawings must contain notes requireing compliance with commissioning requirements - Section 1416 Compliance Option Simple System 0 Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the 1 plans. For projects without plans, fill in the required information below. 1 1f available. 2 As tested according to Table 14 -1A through 14 -1 G. 3 If required. " COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). Revised July 2007 08- 115 NCE System Description If Heating/Cooling 0 Constant vol? 0 Air cooled? 0 Packaged sys? 0 <20,000 Btuh? See Section 1421 for full description or Cooling Only: 0 Split system? • Economizer included? of Simple System qualifications. If Heating Only: 0 <5000 cfm? <70% outside air? • 11• A. 11• 01 . - L•1 0 - 1 • Mechanical Summary (back) • • - • u • . 0 - • 11 MECH -SUM Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. otal Ca •. wo economize <240,000 Btuh or10 %? Heating Only ( Reference Section 1421 Heating'Cooling or Cooling Only Reference Section 1423 Use Complex Systems (section 1430) Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. Open Motors Closed Motors 3,600 1 1.800 1 1.200 3.600 1 1.800 I 1.200 Efficiency ( %) Efficiency ( %) - 82.5 80.0 75.5 82.5 80.0 82.5 84.0 84.0 82.5 84.0 85.5 84.0 84.0 85.5 84.0 84.0 86.5 84.0 86.5 86.5 85.5 87.5 87.5 85.5 87.5 87.5 87.5 87.5 87.5 87.5 88.5 88.5 88.5 89.5 89.5 88.5 89.5 90.2 89.5 89.5 89.5 89.5 91.0 90.2 90.2 91.0 90.2 90.2 91.0 91.0 90.2 91.0 90.2 91.0 91.7 91.7 91.0 92.4 91.7 91.0 92.4 92.4 91.0 92.4 91.7 91.7 93.0 93.0 91.7 93.0 93.0 92.4 93.0 93.0 92.4 93.0 93.0 93.0 93.6 93.6 93.0 93.6 93.6 93.0 94.1 93.6 93.0 94.1 93.6 93.0 94.1 94.1 93.6 94.5 94.1 93.6 94.5 94.1 94.5 94.5 94.1 93.6 95.0 94.5 94.5 95.0 95.0 94.5 95.0 94.5 _ 95.0 95.0 95.0 11• 1. • is •• Electric Motors 1 ► 01" • - 1 . 1- • ••- • 1•• . • - • 11 MECH -MOT 2006 Washington State Nonresidential Energy Code Compliance Farms Project Address Complete the following for all design A & B squirrel -cage, T -frame induction permanently wired polyphase motors from 1 hp to 200 hp having synchronous speeds of 3600, 1800 or 1200 rpm (unless one of the exceptions below applies). n/a Motor No. or Location Minimum Nominal Full-Load Efficienc Synchronous Speed (RPM) HP 1.0 1.5 2.0 3.0 5.0 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 HP 556 Southcenter Mall Type (open /closed) Description of Application or Use Date 4/25/2008 For Building Department Use Synch. Speed Revised July 2007 Min.Nom. Full load Efficiency Exceptions: 1. Motors in systems designed to use more than one speed of a multi -speed motor. 2. Motors already included in the efficiency requirements for HVAC equipment (Tables 14- 1A or 14-1B) . 3. Motors that are an integral part (i.e. not easily removed and replaced) of specialized process equipment (i.e. equipment which requires a special motor, such as an explosion - proof motor). 4. Motors integral to a listed piece of equipment for which no qualifying motor has been approved (i.e. if the only U.L. listing for the equipment is with a less- efficient motor and there is no energy -efficient motor option). For motors claiming an exception, list motor and note which exception applies. Mechanical Permit Plans Checklist MECH -CHK I I 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address 556 Southcenter Mall Date 4/25/2008 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washinaton State Nonresidential Enerav Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance 1.a. 1411.4 Pkg. elec. htg.& dg. List heat pumps on schedule 1.a. 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency 1.a. 1411.1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket loss 1412 HVAC controls yes 1412.1 Temperature zones Indicate locations on plans yes 1412.2 Deadband control Indicate 5 degree deadband minimum no 1412.3 Humidity control Indicate humidistat 2.a. 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types 2.a. 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage 2.a. 1412.4.2 Optimum Start Indicate optimum start controls 1.a. 1412.5 Heat pump control Indicate microprocessor on thermostat schedule x . a . 1412.6 Combustion htg. Indicate modulating or staged control yes 1412.7 Balancing Indicate balancing features on plans 1412.8 Ventilation Control Indicate demand control ventilation for high - occupancy areas 1.a. 1422 Thermostat interlock Indicate thermostat interlock on plans 2.a. 1423 Economizers Equipment schedule 1413 Air economizers i. a. 1413.1 Air Econo Operation Indicate 100% capability on schedule 1.a. 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb 1.8. 1413.2 Water Econo Doc Indicate clg load & water econoe & clg tower performance 1.a. 1413.3 Integrated operation Indicate capability for partial cooling 1.a. 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems yes 1414.1 Duct sealing Indicate sealing necessary yes 1414.2 Duct insulation Indicate R -value of insulation on duct yes 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Completion Requirements yes 1416.2.1 Commissioning Provide commissioning plan yes 1416.2.2 -3 Sys.Bal & Func.Test Indicate air and water system balancing & functional testing yes 1416.2.4 Commissioning Indicate O &M manuals, record drawings, staff training yes 1416.2.5 Comm. Report Indicate requirements for prelim. & final commissioning report 1.a. 1434 Separate air sys. Indicate separate systems on plans Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, dm, hp, economizer SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. 1.a. 1441 Elec. water heater Indicate R -10 insulation under tank 1.a. 1442 Shut -off controls Indicate automatic shut -off 1.8. 1443 Pipe Insulation Indicate R -value of insulation on piping 1.8. 1452 Heat Pump COP Indicate minimum COP of 4.0 1.8. 1452 Heater Efficiency Indicate pool heater efficiency 1.a. 1453 Pool heater controls Indicate switch and 65 degree control 1. a. 1454 Pool covers Indicate vapor retardant cover 1.a. 1454 Pools 90+ degrees Indicate R -12 pool cover 2006 Washington State Nonresidential Energy Code Compliance Form If "no" is circled for any question, provide explanation: Mechanical Permit • Plans Checklist • MECH -CHK 2006 Washington State Nornesidential Energy Code Compliance Fortes Revised July 2007 Mechanical - General Requirements 2006 Washin ton State Nonresidential Ener Code Com • Iiance Form 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14.1A through 14 -1 G. If a nationally recognized certification program exists for a product covered in Tables 14-1A through 14 -1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air fumaces with input ratings? 225,000 Btu /h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable altemative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings > 225,000 Btu/h (65 kW), including electric furnaces, that are riot located within the conditioned space shall have jacket losses not exceeding 0.75% of tie input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Coo Ing Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu/h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or altemate use of the spaces served by the system. The automatic controls shall have a minimum seven-day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity ( nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings three or more stones in height. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply air ranaritiec evroerl inn 1n nnn rfm shall have ■nfime im start rnntrnlc ("Infirm im 1412.8 Ventilation Controls for High - Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct- digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and retum air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 dry-bulb/40 wet -bulb and below. For this calculation, all factors including solar and intemal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air-cooled heat rejection equipment may use a 35 dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu/h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water-cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246- 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu/h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and Iongitdinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut-off damper complying with Ccu'inn 1t11 '7 1 EF CAE < 50 gal storage 0.58 0.71 50 to 70 gal storage 0.57 0.71 > 70 gal storage 0.55 0.70 Mechanical Permit • Plans Checklist • MECH -CHK 2006 Washington State Nornesidential Energy Code Compliance Fortes Revised July 2007 Mechanical - General Requirements 2006 Washin ton State Nonresidential Ener Code Com • Iiance Form 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14.1A through 14 -1 G. If a nationally recognized certification program exists for a product covered in Tables 14-1A through 14 -1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air fumaces with input ratings? 225,000 Btu /h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable altemative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings > 225,000 Btu/h (65 kW), including electric furnaces, that are riot located within the conditioned space shall have jacket losses not exceeding 0.75% of tie input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Coo Ing Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu/h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or altemate use of the spaces served by the system. The automatic controls shall have a minimum seven-day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity ( nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings three or more stones in height. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply air ranaritiec evroerl inn 1n nnn rfm shall have ■nfime im start rnntrnlc ("Infirm im 1412.8 Ventilation Controls for High - Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct- digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and retum air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 dry-bulb/40 wet -bulb and below. For this calculation, all factors including solar and intemal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air-cooled heat rejection equipment may use a 35 dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu/h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water-cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246- 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu/h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and Iongitdinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut-off damper complying with Ccu'inn 1t11 '7 1 .,__residential Energy.Ctade Cortapf a FAf 2. are isolated from the exterior with an automatic shut -off damper complying with Section 1412.4.1. Once outside air ducts meet the above listed requirements, any runs within conditioned space shall comply with Table 14 -5 requirements. Other ducts and plenums shall be thermally insulated per Table 14-5. Exceptions: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a zone that serves that zone. 1415 Piping Systems 1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14-6. Exception: Piping installed within unitary HVAC equipment. Water pipes outside the conditioned space shall be insulated in accordance with Washington State Plumbing Code (WAC 51 -26) 1416 Completion Requirements (Refer to NREC Section 1416 and the Building Commissioning Guidelines, published by the Building Commissioning Association, for complete text and guidelines for building completion and commissioning requirements.) 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum start controls shall be designed to automatically adjust the start time of an HVAC system each day to bring the space to desired occupied temperature levels immediately before scheduled occupancy. The control algorithm shall, as a minimum, be a function of the difference between space temperature and occupied setpoint and the amount of time prior to scheduled occupancy. 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start-up, set- up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shall indicate when supplemental heating is being used through visual means (e.g., LED indicators). 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 000 EXCEPTIONS: 1. Boilers. 2. Radiant heaters. 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have a means for balancing, including but not limited to, dampers, temperature and pressure test connections and balancing valves. ACTIVITY NUMBER: M08 -125 DATE: 04 -30 -08 PROJECT NAME: OAKLEY SITE ADDRESS: 556 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: x,06 1 IIfl r r, B I •� g • ision Comments: TUESITHURS ROUTING: Please Route Documents/routing slip.doc 2 -28 -02 • PLAN Ffg LT COORD COPY ON/ROUTING SLIP - A - - Fire Prevention Public Works n Structural Structural Review Required APPROVALS OR CORRECTIONS: Approved ri Approved with Conditions Notation: REVIEWER'S INITIALS: (1 Planning Division No further Review Required DATE: n ❑ Permit Coordinator U DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 05 -01 -08 Complete 171 Incomplete ❑ Not Applicable ri Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: REVIEWER'S INITIALS: DATE: DUE DATE: 05 -29 -08 n Not Approved (attach comments) n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License LAKEVCI072KC Licensee Name LAKEVIEW CONSTRUCTION INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601447862 Verify Workers Comp Premium Status Ind. Ins. Account Id 86508200 Business Type CORPORATION Address 1 10505 CORPORATE DR, #200 Address 2 01/01/1980 City PLEASANT PRAIRIE County OUT OF STATE State WI Zip 53158 Phone 4146574222 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 5/3/1993 Expiration Date 1/13/2009 Suspend Date Separation Date Parent Company Previous License STATECC113B3 Next License Associated License Business Owner Information Name Role Effective Date Expiration Date SUNDAY, EUGENE R PRES 01/01/1980 MOON, KENT A VP 01/01/1980 SUNDAY, EUGENE R SECRETARY 01/01/1980 MOON, KENT A TREASURER 01/01/1980 Look Up a Contractor, Electricn or Plumber License Detail Printer Friendly Version Topic Index 1 Contact Info Find a Law or Rule Get a Form or Publication • 3S asJ iimon'SiateDcpartmcint o r C R IntlWlies Look Up a Contractor, Electrician or Plumber J General /Specialty Contractor A business registered as a construction contractor with LEtI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. & Licensing Page 1 of 2 Search ea Help https: // fortress .wa.gov /lni/bbip/Detail.aspx ?License= LAKEVCI072KC 06/09/2008 Air Distribution Schedule MARK MODEL NUMBER MAKE DU DUTY CONNECT, SIZE FACE SIZE SELECTION JAIR FLOW PATTERN INSTALLATION FINISH REMARKS ACCESSORIES SUPPLYRETURNEXHAUST CFM MAX. N.C. LEVEL DUCT CEILING WALL A FL -10 -JT TITUS X 12 "0 48"X1" 500 30,0 JET THROW X WHITE WITH INSULATED FBPI -I5 -JT PLENUM a 0 B FL -10 -HT TITUS X _ - 12 "0 48 "X1" 500 30.0 HI -THROW X WHITE H -IHT INS ED PLEN - UM o 0 C F1-10 TITUS X . N/A L* X1" 400 30.0 N/A X WHITE NON- DUCTED (PLENUM RETURN) O D PCS TITUS X 8 "0 24 "x24" 200 30.0 4 -WAY X WHITE E PAR TITUS X 14 "o 24"X24" 200 30.0 N/A X WHITE F 300RS TITUS X 14 "0 24"X24" 200 30.0 N/A X WHITE VAV IDENTIFICATION DESIGN CFM MEASURED CFM DISCHARGE S.P, ( "WG) DISCHARGE TEMP. ('F) VAV -1 1530 1 HVAC LOAD CALCULATIONS AIr System Information AIr System Name VAV-1 Equipment Class UNDEF Air System Type VAV Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible Toad Space CFM Individual peak space Toads Central Cooling Coll Sizing Data Total coil load 2.8 Tons Total coil load 34.1 MBH Sensible col load 30.0 MBH Coil CFM at Jun 1300 1421 CFM Max block CFM at Jun 1500 1453 CFM Sum of peak zone CFM 1453 CFM Sensible heat ratio 0.880 ft'/Ton BTU /(hr -fr) Water flow © 10.0 °F rise Supply Fan Sizing Data Zone Sizing Data Zone Name Zone 1 Zone Terminal Sizing Data Space Loads and Airflows Zone Name / Space Name Zone 1 Office/Dressing Sales Stock ZONE LOADS Window & Skylight Solar Loads Wall Transmission Roof Transmission Window Transmission Skylight Transmission Door Loads Floor Transmission Partitions Ceiling Overhead Lighting Task Lighting Electric Equipment People Infiltration Miscellaneous Safety Factor >7 Total Zone Loads Zone Conditioning Plenum Wall Load Plenum Roof Load Plenum Lighting Load Return Fan Load Ventilation Load Supply Fan Load Space Fan Coll Fans Duct Heat Gain / Loss » Total System Loads Central Cooling Coil Preheat Col Terminal Reheat Coils » Total Conditioning Key: 470.8 25.5 6.83 gpm Preheat Coil Sizing Data No heating coil Toads occurred during this calculation. Actual max CFM at Jun 1500 1453 CFM Standard CFM 1429 CFM Actual max CFM/ft= 1.08 CFM/ft OutdoorVentllatlon AIr Data Design airflow CFM 0 CFM CFM/11 0.00 CFM/ft' Alr System Information AIr System Name VAV Equipment Class UNDEF Air System Type VAV Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible load Space CFM Individual peak space loads Maximum Cooling Sensible (MBH) 26.2 Reheat Coll Load Zone Name (MBH) Zone 1 10.9 Mult 1 1 1 Details O 11 0 ft 1339 fr 011 ft 0 flz 1339 ft' Oft; 0 ft 3046 W 1578 W 1227 W 18 10%/10% 0% 0% 0% 1421 CFM O CFM 1421 CFM Cooling Sensible (MBH) 1.9 20.4 4.0 Design Air Flow (CFM) 1453 Reheat Coil Water gpm @20.0 °F 1.09 Sensible (BTU/hr) 0 0 3497 0 0 0 0 0 0 8213 4757 3795 3264 0 0 2353 25878 30035 0 0 0 0 0 0 0 0% 0 30035 30035 0 0 30035 Positive values are clg Toads Negative values are htg Toads Number of zones - 1 Floor Area 1339.0 fN Location Tukwila, Washington Calculation Months Jan to Dec Sizing Data Calculated Load occurs at Jun 1300 OA DB /WB 82.0/64.4 °F Entering DB /W13 74.9 / 62.3 °F Leaving DB / WB 55.0 / 53.8 °F Coil ADP 52.8 °F Bypass Factor 0.100 Resulting RH 50 % Design supply temp. 55.0 F Zone T-stat Check 1 of 1 OK Max zone temperature deviation 0.0 °F Fan motor BHP 0.00 BHP Fan motor kW 0.00 kW Fan static 0.00 In wg CFM/person 0.00 CFM/person Number of zones 1 Floor Area 1339.0 ft Location Tukwila, Washington Calculation Months Jan to Dec Sizing Data Calculated Jun 1400 Jun 1500 Jun 1400 Minimum Air Flow (CFM) 436 Time of Load DESIGN COOLING COOLING DATA AT Jun 1300 COOLING OA DB / WB 82.0 °F / 64.4 °F Zone Htg Coil Load (MBH) 0.0 Latent (BTU/hr) 3701 0 0 370 4071 4071 0 4071 4094 4094 Air Flow (CFM) 103 1129 222 Time of Peak Load Jun 1500 Zone Htg Water gpm @20.0 °F 0.00 Heating Load (MBH) 0.5 2.8 0.7 Maximum Heating Load (MBH) 4.0 Mixing Box Fan Airflow (CFM) 75 Zone Floor Area (Fr) 1339.0 Floor Area Space (ft=) CFM/ft= 182.0 934.0 223.0 0.57 121 0.99 DESIGN HEATIF.', HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F 09.2 °F Sensible Latent Details (BTU/hr) (BTU /hr) 0ftz - 0ftt 0 1339 ft' 3058 0ft' 0 Oft' 0 011 0 1339 ft 0 Oft' 0 Oft' 0 0 0 0 0 O 0 - 0 0 0 D 0 D 0 30% 917 0 3975 0 3655 0 D 0 - 0 0 O 0 436 CFM 0 - O CFM 0 0 436 CFM 0 - .48 0% .. 0 3607 0 -5753 0 0 - 9360 - 3607 0 Positive values are htg loads Negative values are clg loads Zone CFM/ft= 1.08 Fan Powered Terminal Unit with Electric Heat Schedule Tag FPVAV -01 Notes: Model ATQP Size Unit Inlet Outlet 03 I 12 14x11 CFM Max Min 1530 500 Static Pressure Inlet I Down I Min 0.8 0.5 0.28 1. Room NC level shown includes attenuation transfer functions from tables in ARI Standard 885 -89. 2. Sound data shall be obtained from tests conducted in accordance with ARI Standard 880 -94. 3. Selections based on Titus as Manufacturer. 4. Duct dimensions are approximate. Check submittal drawings for exact dimensions. NC Levels tad. Disc 38 22 Fan CFM 750 ESP Hp 0.5 0.25 CFM 1250 Electric Heating Coil kW I EAT/ LAT Volts / Ph. 9 64/86.8 480/3 VAV Pre -Test AIR BALANCING CONTRACTOR SHALL FILL OUT FOLLOWING FORM AND FORWARD TO ENGINEER, ARCHITECT, AND OWNER AFTER TESTING AND BEFORE FINAL FRAMING OF CEILING, L.L. MED. PRESS. MAIN DUCT COMPANY TECHNICIAN'S NAM AABC/NEBB (CIRCLE ONE)) CERTIFICATION # TIME_ DATE, MALI. ENGINEER O.A. TEMP F' VAV -1 TYP) VAV -2 VAV -... H.V,A.C. CONTRACTOR SHALL INSTALL A MINIMUM OF 5' -0" OF MEDIUM PRESSURE DUCTWORK FROM EXISTING OR NEW TAPS IN THE SIZE AS NOTED ON DRAWINGS FOR C.F.M., STATIC PRESSURE AND DISCHARGE AIR TEMPERATURE TESTING. EACH DUCT SHALL BE PROVIDED WITH A TEMPORARY MANUAL BALANCING DAMPER WITH LOCKING QUADRANT DAMPER. IF EXISTING V.A.V. BOXES ARE NOTED TO BE REUSED, THEN TEMPORARY BALANCING DAMPERS NEED NOT BE INSTALLED. H.V.A.C. CONTRACTOR, PRIOR TO TESTING SHALL INFORM THE LANDLORD OF HIS INTENTIONS SO THAT THE LANDLORD CAN CONFIRM THAT HIS UNIT IS RUNNING AT CAPACITY. THE AIR BALANCING CONTRACTOR SHALL PERFORM A PRELIMINARY AIR BALANCE OF V.A.V. SYSTEM SETTING ALL DAMPERS OR EXISTING V.A.V. BOXES TO THE REQUIRED C.F.M. AS NOTED ON THE MECHANICAL EQUIPMENT SCHEDULE. C.F.M. READINGS, STATIC PRESSURE READINGS AND DISCHARGE AIR TEMPERATURE READINGS SHALL BE RECORDED ALONG WITH THE TIME OF DAY AND OUTDOOR AIR CONDITIONS WHEN READINGS WERE TAKEN. THIS INFORMATION, ALONG WITH AIR BALANCE CERTIFICATION NUMBER, SHALL BE FORWARDED TO THE MECHANICAL ENGINEER. APPROVAL SHALL BE OBTAINED FROM THE MECHANICAL ENGINEER PRIOR TO THE INSTALLATION OF ANY DUCTWORK, THIS TEST MUST BE PERFORMED PRIOR TO FABRICATION OF ANY DUCTWORK, ANY FABRICATION OF DUCTWORK PRIOR TO THIS SHALL BE AT THE CONTRACTOR'S OWN FINANCIAL RISK. H,V,A,C, CONTRACTOR, UPON APPROVAL FROM MECHANICAL ENGINEER, SHALL REMOVE TEMPORARY MANUAL BALANCING DAMPER AND COMPLETE INSTALLATION OF DUCTWORK AND V.A.V. BOXES IN ACCORDANCE TO SPECIFICATIONS AND DETAILS. FAX RESULTS OF TEST TO ARCHITECT, OWNER'S PROJECT MANAGER, AND MECHANICAL ENGINEER AND OBTAIN APPROVAL PRIOR TO DUCT FABRICATION. *: LENGTH OF TYPE "C" DIFFUSER, FL -10, SHALL BE CONTINUOUS ACROSS SALES CEILING, TO LENGTH SHOWN ON ARCHITECTURAL PLANS. ACCESSORIES: PER 2006 IMC SECTION 606 Install smoke detector to shut down air distribution by VAV's when the total combined C F M of all VAV's (to include other tenants) sharing the same plenum space exceeds 2000 CFM. (See IMC 606.2.2 for approved method of detection) MECHANICAL EQUIPMENT SCHEDULE uEfrARATE PERMIT REQUIRED FOR: ❑ Mechanical gElectrica) LWL Plumbing Gas Piping I City of Tukwila i BUILDING DIVISION REVISIONS No changes shall be made to the scopA of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. ff ..1 PROVIDE YOUNG REGULATOR 5020CC ROUND DAMPER IN SHEET METAL DUCTWORK AHEAD OF FLEX DUCT, WITH YOUNG REGULATOR CABLE - ACTUATED DAMPER, ADJUSTABLE THROUGH FACE OF DIFFUSER WITH SOCKET WRENCH FOR AIR BALANCING. FILE O2 PROVIDE TAPE -IN TYPE CONCEALED BORDER FRAME AROUND DIFFUSER. Permit No. Plar review approval is subject to errors and lio Appravai of construction documents does not motorize the violation of any adopted #.•, or ordinance. Receipt of approved Field aind �.�� *: ... s is ache: By Date: � U City of Tukwila BUILDING DIVISION 1 LEGEND SYMBOL DESCRIPTION II�IL�I R 1 1 1 1 1 - 1 RECTANGULAR RETURN/ EXHAUST/ SUPPLY DUCT .77 INTERNALLY INSULATED RECTANGULAR RETURN/ EXHAUST/ SUPPLY DUCT FLEXIBLE DUCT (6'-0" MAX. U.O.N.) IIIIIIIIIU))I z A.F.F. B.O.D. CL CD (E) E.C. EF M.C. M.V.D. (N) N.I.C. NTS O.B.D. O.S.A. P.O.C. PROVIDE (R) S.D. U.O.N. SUPPLY AIR DUCT UP EXHAUST AIR DUCT UP RETURN AIR DUCT UP ROUND RETURN /EXHAUST /SUPPLY DUCT CEILING SUPPLY DIFFUSER CEILING EXHAUST REGISTER CEILING RETURN GRILLE THERMOSTAT (MOUNT AT 48" A.F.F.) REMOTE TEMPERATURE SENSOR (MOUNT AT 48" A.F.F.) DUCT - MOUNTED SMOKE DETECTOR POINT OF CONNECTION TO EXISTING ITEMS ABBREVIATIONS FOR ': REVIEWED CODE COMPLIANCE M APPROVED . 1 MAY - 8 200 ty Of Tukwila BUILDIh..: DIVISION ABOVE FINISHED FLOOR BOTTOM OF DUCT CENTER LINE CONDENSATE DRAIN EXISTING ELECTRICAL CONTRACTOR EXHAUST FAN MECHANICAL CONTRACTOR MANUAL VOLUME DAMPER NEW NOT IN CONTRACT NOT TO SCALE MANUAL OPPOSED BLADE BALANCING DAMPER OUTSIDE AIR (FRESH AIR) POINT OF CONNECTION TO EXISTING ITEMS FURNISH, INSTALL AND CONNECT RELOCATE DUCT - MOUNTED SMOKE DETECTOR UNLESS OTHERWISE NOTED DRAWING SCHEDULE M0.1 Mechanical Legend, Schedules, and Load Calculations M0.2 Mechanical Details and Specifications M0.3 Mechanical Details M2.1 Mechanical HVAC Reflected Ceiling Plan Valerio Architects Architecture, Design & Planning DATE: " Apr 25, 2008 ENCON ENERGY • CONSERVATION • COMPANY OAKLEY 556 SOUTHCENTER MALL TUKWILA, WA 98188 A Date DESCRIPTION 4/26/08 REVIEW SET 4/28/08 PERMIT/BID/LL REVIEW SET Date Modified: Date Created: Scale: Project No.: Drawn By: CAD File: 5858 Wilshire Blvd, Ste 203 Los Angeles, CA 90036 Telephone: 323.954. 96 Facsimile: 323.954.8965 url: www °valerioarchitects.com Email: info®valerioarchitects°com CONSULTANT 720 Sunrise Ave, Suite 208B Roseville, CA 95661 tel # (916) 772 -8440 fax # (916) 772 -8441 email info@encon.com Copyright o ENCON 2008 ENCON Project #:0K6118.00 { EXPIRES 11/6/ a.9 PROJECT This document contains information proprietary to the Architect and Is furnished in confidence for the limited perupose of evaluation, bidding or review. This document or Its contents may not be used for any other purpose and may not be reproduced or disclosed to others without the prior written consent of the Architect ®C NEE) Mechanical Legend, APR 30NOB Schedules, and DERMIT CENTS Load Calculations 4/25/08 4/15/08 AS SHOWN 586 -08 -29 BMS /RDM ENCON 0K6181.00 =7r; MINIM ••• SECTION 15500 - HEATING, VENTILATING AND AIR CONDITIONING 1.00 - GENERAL 1.01 DESCRIPTION OF WORK Furnish and install complete and operative HVAC system as shown on the drawings and specified herein. Work shall include, but not be limited to the following: A. HVAC units, see mechanical equipment schedule for more information. B. Toilet exhaust ductwork and termination with roof cap, wall Tower, or connection to central exhaust system, as applicable. C. Automatic temperature controls system including 7-day programmable thermostat(s), remote temperature sensor(s) and all control wiring and accessories required for a complete and functional system. See mechanical equipment schedule for more information. D. Ductwork and air distribution devices. E. Air balancing dampers at each diffuser and duct branch (regardless if shown on plan drawing or not). F. Hangers and supports for ductwork, piping and HVAC equipment G. Flashing of duct and pipe penetrations through exterior openings. H. Support hardware and vibration insulation for HVAC units. I. Duct Thermal and Acoustic Insulation. J. License, Permits and associated fees. K. Seismic restraints and bracing, when required. L. Duct Smoke Detectors for all HVAC equipment (new and existing) as required by local codes. 1.02 RELATED WORK INCLUDED UNDER OTHER SECTIONS A. Fire Protection, Section 15300. B. Plumbing, Section 15400. C. Testing and Balancing Section 15990. D. Line Voltage and Power Wiring, Electrical Section 16000. 1.03 EXAMINATION OF SITE Visit site before submitting bid and check location of all existing conditions that will affect this work, verify dimensions and locations shown on drawings and cover all costs. Contractor shall assume reasonable variations or minor omissions and shall complete proposed work without additional cost. Failure to visit site will not lessen responsibility or entitle additional compensation for work not included in proposal. 1.04 DRAWINGS The accompanying drawings shall be considered part of these specifications. Work and materials shown on the drawings and not mentioned in the specifications and vice versa shall be executed as if specifically mentioned or shown in both. The drawing shall be considered as schematic in nature and minor modifications of the work to comply with the structure as found shall be made. 1.05 RULES AND REGULATIONS A. All work and material shall be in full accordance with the latest rules and regulations of the State Fire Marshal and other applicable State and local rules and regulations. Nothing in these drawings or specifications shall be construed to permit work not conforming to these codes. B. Furnish without any extra charge any additional material and labor when required to comply with these laws, ordinances and codes regardless of whether shown or mentioned in these specifications or drawings. 1.06 SUBMITTALS Submit for review to Architect a complete and all- inclusive list of equipment and materials proposed for use (6 copies), accompanied by manufacturer's data sheets. Data shall be forwarded in a single package within 15 days after award of contract. Submit six copies of each shop drawing showing proposed ductwork installation. Include sizes, locations and other required information to coordinate installation with other trades. 1.07 AS -BUILT DRAWINGS A set of HVAC Prints will be furnished to the Contractor on which he shall indicate the installation "as- built" as the work progresses. Upon completion of the work, a copy of the original design drawings shall be obtained from Architect at cost, and all changes as noted on the record set of prints shall be incorporated thereon. Four copies of the set of "as- built" drawings shall be delivered to the Architect upon completion and before final acceptance of the project. 1.08 GUARANTEE The Contractor shall leave the entire installation in complete working order free from any defective material, workmanship or finish. The Contractor shall guarantee to repair or replace, without charge, defects due to faulty workmanship or material for a period of one year from the date of filing of the Notice of Completion. 1.09 OPERATION MANUALS AND OWNER INSTRUCTIONS A. Provide complete operation and maintenance manuals covering all mechanical systems and equipment that have been installed. Three (3) copies of the manual shall be bound in hardback binders. B. Provide instructions to owner as to operation of all HVAC equipment. Instruction period to commence for minimum of (2) hours and shall be scheduled at owner's convenience. 1.10 CUTTING AND PATCHING A. The contractor shall do all cutting, drilling and patching which may be required for the installation of the work under this Section of the Specifications. B. Patching shall be of the same workmanship, material, and finish and shall match accurately all surrounding construction in a manner satisfactory to Architect. No cutting of the structure shall be permitted without written approval of Architect. MECHANICAL SPECIFICATIONS 2.00 - PRODUCTS 2.01 DUCTWORK Shall be as specified in the following schedules. Materials shall be clearly stamped or marked with grades and gauges. A. Sheet metal rectangular ductwork, plenums and casing construction shall be in strict accordance with SMACNA's "HVAC Duct Construction Standards: Metal and Flexible, (latest edition). B. Sheet metal round duct shall be single -wall (unless otherwise specified on drawings), machine formed, with continuous interlocking helical seam: United McGill's "Uniseal" or approved equal. C. Materials for ductwork shall be galvanized steel, of gauges shown in SMACNA's "HVAC Duct Construction Standards: Metal and Flexible, (latest edition). All ductwork shall be constructed in accordance with the pressure - velocity classification standards no Tess than +/- 2"WG and ASHRAE duct sealing Level "B" (All transverse joints and longitudinal seams) for concealed ductwork, and no less than +/- 2"WG and ASHRAE duct sealing Level "A" (All transverse joints, longitudinal seams, and duct wall penetrations) for exposed or exterior ductwork. D. Flexible ductwork shall be pre - insulated low- pressure type (rated to 4" WG) with vapor barrier. Ducts shall meet Class 1 requirements of NFPA 90A and shall be labeled by U.L. Flexible ducts shall be ATCO Rubber Products, 30 Series or approved equal. Flexible duct is allowed only at final connections to air distribution fixtures at lengths of five feet maximum. E. Unless shown otherwise, all insulation shall be external to ductwork. 2.02 DUCTWORK ACCESSORIES A. Damper Regulators 1. Ducts with internal insulation or no insulation: DuroDyne "Quadline Damper Quadrant ", or equivalent from Young Regulator, Ventfabrics, Hardcast, or approved equal. 2. Ducts with external insulation: DuroDyne "ESO series" elevated locking quadrant regulator set, or equivalent from Young Regulator, Ventfabrics, Hardcast, or approved equal. B. Flexible Connections: Ventfabrics "Ventglas ", DuroDyne, or approved equal, U.L. approved with metal attachment. C. Air Extractor Titus AG -225, Krueger EX -88, or approved equal. D. Turning Vanes shall comply with SMACNA HVAC Duct Construction Standards All rectangular ducts with mitered elbows shall be fitted with turning vanes. E. Spin -In- Fittings are not allowed. Use United McGill Bellmouth fitting or approved equal for round duct taps. F. Support ductwork according to the SMACNA Duct Construction Standards and the drawings. G. Access Doors In Ductwork: Shall be Ventfabrics, Ductmate or approved equal, stamped or formed insulated access doors complete with all hardware and sealant. H. Joint Sealing: 1. The following items are to be sealed with Hardcast DT tape and RTA 50 adhesive: a. Longitudinal and transverse seams of rectangular ductwork. b. All round fittings and joint connectors. 2. Flexible duct at diffusers shall use integral stainless steel draw band and pressure sensitive tape, Hardcast FG 1402 -181 BFX or equal. I. Bracings, hangers, nuts, etc. shall be galvanized steel. J. Curved elbows shall have centerline radius equal to one and one -half times duct width in plane of turn. K. Square elbows shall have turning vanes. Mitered elbows shall have splitter vanes three inches on center. L. Volume dampers shall be constructed to SMACNA Standards and shall be Young Regulator 4040 or Ruskin MDRS25 for round ducts and Young Regulator series 820 or Ruskin MD35 for rectangular ducts. 2.03 AIR DEVICES Acceptable manufacturers for Grilles and Registers: Titus, Krueger, Metal*Aire, Price, or appr oved equal. Furnished and installed by Mechanical Contractor. Provide volume dampers and paint interior flat black. Size, finish, frame types and accessories as shown on the dwgs. 2.06 INSULATION (Installed per Manufacturer's Recommendations) A. Heating and Cooling Ductwork located in interior locations: Insulate with Owens- Coming SoftR Fiber glass all service Duct Wrap, Type 150 with factory applied flame retardant Foil Reinforced Kraft Facing (FRK -25 U.L. labeled), or approved equal. Installed thermal resistance shall be a minimum of 4.2, but shall be higher as required by local energy code requirements. B. Acoustical Ductwork and Plenum and Casing Liner. 1. Provide internally lined ductwork where indicated on drawings. Acoustical duct liner shall be Certainteed Ultralite, Owens Coming quietR, or equal, matte face, 3 Ib. density, 1" thick, suitable for velocities from 1500 to 4000 fpm, in compliance w/ UL723 and UL181. Secure liner to ductwork with adhesive and mechanical fasteners per SMACNA Duct Liner application standard. 2. Where internal insulation is applied, duct and plenum sizes as shown on the drawings shall be inside clear dimensions. 3. Fiberglass duct and plenum insulation are to be applied only with manufacturer's approved adhesives, mastics and mechanical fastening devices. 2.07 TEMPERATURE CONTROL SYSTEM A. Contractor shall furnish all necessary control devices (relays, contacts, wiring, etc.) and shall provide a temperature control system as specified in the equipment schedule. B. Contractor shall post in the office typewritten instructions on operation of all controls. 3.00 - INSTALLATION AND EXECUTION 3.01 INSTALLATION REQUIREMENTS A. Ductwork: 1. Duct branches shall be fitted with volume or splitter damper and where required, extraction damper. All accessible volume controls shall have locking quadrant regulatorss. All inaccessible controls (dampers, etc.) shall be provided with permanent extensions (such as Young Regulator "Bowden" remote control cable system) to accessible spaces. Branch volume controls are in addition to volume controls at registers and diffusers. 2. Air inlets, outlets shall be properly set in place. Registers and grilles shall be tightly sealed. 3. Transitions in size of ducts shall be made by uniformly tapering sections having 1 inch increase in width for each 7 inches of run unless construction limitations require a more abrupt transition. 4. Diffusers, Grilles and Registers: Each register and diffuser shall be equipped with a volume damper or air extractor. Paint interior surface of all units flat black. Face and trim of all units shall be finished. Size, finish, frames, accessories, capacity and pattern as shown on drawings. 5. Contractor shall provide manual volume dampers at all branch ductwork in supply air, return air and outside air systems (whether shown on plans or not) where required for air balancing of HVAC systems. SECTION 15990 - TESTING, ADJUSTING AND BALANCING 1.00 - GENERAL 1.01 DESCRIPTION The testing and balancing work will be performed under a separate contract from the HVAC work. The work described in this section shall be performed by an independent test and balance agency, specializing in testing and balancing of HVAC systems and a number of the AABC or approved equal organization. 1.02 SCOPE OF WORK A. HVAC System Test and Balance in accordance with procedures established by AABC or NEBB. B. Measurement of final operating conditions of HVAC equipment. C. Test and Balance Reports, (4) copies. D. Each piece of air conditioning and heating equipment and the air distributions systems shall be tested and adjusted to insure proper functioning of all control, proper distribution of air, maintenance of temperature, elimination of drafts, noise and vibration, and left in first class operating condition. The air system shall be readjusted if required for comfort of each room. E. The mechanical contractor will make any changes in the pulleys, belts, dampers, vanes, baffles and the like required for correct balance of system as recommended by Test and Balance agency and to the satisfaction of the owner. 1.03 SUBMITTALS A. The test and balance report shall include, as a minimum, but not be limited to: 1. Each equipment shall be identified by equipment service number, manufacturer, model number, and serial number, motor horsepower, motor nameplate voltage, motor RPM, actual and design static pressure, actual outlet velocity, actual CFM, design CFM. 2. Each coil shall be identified by equipment service number, manufacturer, model number and size, number of rows, total CFM, air inlet and outlet dry bulb and wet bulb temperatures. 3. Each air outlet shall be identified with manufacture, model number, size, velocity, correction factor, actual CFM, design CFM. 4. Traverse reading of main supply, return and outside air ducts to establish air quantities. 5. Test and record temperatures from temperature controllers such as day thermostat, night thermostat. 6. Test and record temperatures from main supply air trunk, mixed air during the full heating and full cooling cycle and economizer cycle. 7. Test and balance economizer. END OF SECTION 1 3/8" DIA, ROD OR �iII `�; GA. HANGER STRAP III . 1- 1/8"X12 GA SPLIT RING COLLAR AROUND DUCT 1"X16" GA. HANGER STRAP(TYP) MECHANICAL DETAILS THESE TWO HANGERS ARE FOR DUCTS 25" & LARGER (MAY BE USED ON SMALLER DUCTS) r NUT & LOCKNUT 1/4" BOLT. NUT & STAR WASHER (TYP) 1"X16 GA HANGER STRAP 1"X16 GA CONTINUOS HANGER STRAP (TYP). EACH STRAP ADJACENT TO ONE ANOTHER AT HANGER LOCATION (TYP.) ROUND DUCT HANGER 3/8" DIA. ROD ./4 HANGER 1"X16 CA HANGER STRARA P 60" MAX SHT METAL SCREWS (TYP.) NOTES; 1. REFER TO SPECIFICATIONS FOR HANGER SPACINGS. 2. ATTACHMENTS TO OVERHEAD STRUCTURE SHALL BE MADE IN ACCORDANCE WITH STRUCTURAL ENGINEERS UMITATIONS. ALL ATTACHMENT METHODS TO STRUCTURE SHALL BE SUBMITTED TO STRUCTURAL ENGINEER FOR RENEW. DUCT SUPPORTS N.T.B. THIS HANGER IS FOR DUCTS 24" DIA & SMALLER 3 /8 "BOLT,NUT & STAR WASHER 1"X16 GA CONTINUOS COLLAR DRAWN TIGHT AROUND DUCT 2"X2"X1/8" ANGLE TOP & BOTTOM 1"X18 GA STRAP O(TYPVER .) DUCT OVAL/RECTANGULAR DUCT HANGER 1 & Ov ER ®NGLE 4 5• A (TYP) REQUIREMENTS AND WEIGHT 9 REVIEWED FOR CODE COMPU ANCE APPROVED MAY • 8 IMO City Of Tukwila • I BUILDING DIYIQ1 DATE: Apr 25, 2008 Date Modified: Date Created: Scale: Project No.: Drawn By: CAD File: Valerio Architects Architecture, Design & Planning 5858 Wilshire Blvd, Ste 203 Los Angeles, CA 90036 Telephone: 323.954.8996 Facsimile: 323.954, 8965 url: www.valerioarchltects.com Email: info@valerioarchitects,com CONSULTANT ENCON ENERGY • CONSERVATION • COMPANY 720 Sunrise Ave, Suite 208B Roseville, CA 95661 tel # (916) 772 -8440 fax # (916) 772 -8441 email info@encon.com Copyright @ ENCON 2008 ENCON Project #:0K6118,00 `EXPIRES It/6/ 1 PROJECT OAKLEY 556 SOUTHCENTER MALL TUKWILA, WA 98188 A Date DESCRIPTION 4/26/08 REVIEW SET 4/28/08 PERMIT /BID/LL REVIEW SET This document contains information proprietary to the Architect and is furnished in confidence for the limited perupose of evaluation, bidding or review. This document or its contents may not be used for any other purpose and may not be reproduced or disclosed to others without the priorwritfen consent of the Architect. RECER,Wd Mechanical details APR 3 0 Zone and Specifications PERMIT CENTL., 4/25/08 4/15/08 AS SHOWN 586 -08-29 BMS /RDM ENCON 0K6181.00 60" MIN, #12 AWG WIRE SEISMIC /SWAY BRACE Q EACH CORNER TO STRUCTURE, TYP, VAV TERMINAL UNIT FLEX CONN, ACOUSTICALLY LINED S.M. PLENUM FR. UNIT DISCHARGE N.T.S. A ATTACH SUPPORT STRAPS TO BUILDING STRUCTURE 1"x18 GA. HANGER STRAP, LENGTH AS REVD. BOLT TO SUPERSTRUT, 4 STRAPS EA, UNIT WIRE BRACE MED, PRESSURE INLET DUCT FLEX CONN, FAN - POWERED VAV BOX MOUNTING SECURE STRAP TO VAV TERMINAL W/ S.M. SCREWS (TYPICAL OF 3 PER STRAP) 1 MECHANICAL DETAILS S.A. DUCT NOTES., TITUS FBPI INSULATED PLENUM BOX HORIZONTAL DIFFUSER MOUNTING N.T.S. 5020CC ROUND DAMPER OR 83OACC RECTANGULAR OPPOSED BLADE DAMPER FLEXIBLE CASING AND WIRE (50' -0" MAXIMU RIGID DUCTWORK wsmsszsamumuxt% \Nauttttt nn. 'au w•nttt *tom FLEXIBLE DUCTWORK GYP, BOARD CEILING 1. THE 270 -275 BOWDEN CABLE CONTROL SYSTEM IS DESIGNED FOR USE WITH EXTERNALLY CONTROLLED ROUND OR RECTANGULAR DAMPERS, AND CAN BE MOUNTED IN A WIDE VARIETY OF LOCATIONS INCLUDING CEILING JOISTS, LAY —IN CEILINGS, BEHIND GRILLES, ON OR INSIDE OTHER VARIOUS TYPES OF DIFFUSERS, ETC. 2, CABLE SHALL CONSIST OF BOWDEN CABLE 0.054" STAINLESS STEEL CONTROL WIRE ENCAPSULATED IN 1/16" FLEXIBLE GALVANIZED SPIRAL WIRE SHEATH, 3. LOCKING RACK AND PINION GEAR DRIVE SHALL BE CONSTRUCTED OF 14 GAUGE STEEL AND SHALL BE USED TO CONVERT ROTARY MOTION INTO PUSH—PULL MOTION. 0 SUPPORT CABLE INSULATED FLEXIBLE DUCTWORK 3 S 9111 111111111 1• GYP, BOARD CEILING SLOT OPENING: HORIZONTAL FLOWBAR JT DIFFUSER WITH TAPE— IN CONCEALED BORDER FLUORESCENT LIGHTING SEE ARCH. PLANS FOR EXACT SOFFIT /CLOUD CONFIGURATION AND DIMENSIONS 3 REMOTE DAMPER OPERATOR, HORIZONTAL DIFFUSER MO.3 N.T.S. LOCKING RACK & PINION OPERATOR MOUNT BRACKET INSIDE PLENUM BOX FOR ACCESS THROUGH SLOT SOCKET WRENCH 5020CC ROUND DAMPER OR 830ACC RECTANGULAR OPPOSED BLADE DAMPER FLEXIBLE CASING AND WIRE (50' -0" MAXIMUM) AIR ENTRY COLLAR INSULATED PLENUM BOX NQTESz k WergezmIspilutieNnp 1 1 1 HANGER WIRE SAFETY HANGER ---- CEILING LINEAR SLOT DIFFUS WITH PLENUM BOX VERTICAL —MOUNT FLOWBAR HT DIFFUSER WITH TAPE— IN CONCEALED BORDER SLOT OPENING: VERTICAL DIFFUSER MOUNTING N.T.S. RIGID DUCTWORK FLEXIBLE DUCTWORK •�i airrioy�� 4� FLEX, DUCT S.A. DUCT 7SOCKET WRENCH 1, THE 270 -275 BOWDEN CABLE CONTROL SYSTEM IS DESIGNED FOR USE WITH EXTERNALLY CONTROLLED ROUND OR RECTANGULAR DAMPERS, AND CAN BE MOUNTED IN A WIDE VARIETY OF LOCATIONS INCLUDING CEILING JOISTS, LAY —IN CEILINGS, BEHIND GRILLES, ON OR INSIDE OTHER VARIOUS TYPES OF DIFFUSERS, ETC. 2. CABLE SHALL CONSIST OF BOWDEN CABLE 0,054" STAINLESS STEEL CONTROL WIRE ENCAPSULATED IN 1 /16" FLEXIBLE GALVANIZED SPIRAL WIRE SHEATH. 3. LOCKING RACK AND PINION GEAR DRIVE SHALL BE CONSTRUCTED OF 14 GAUGE STEEL AND SHALL BE USED TO CONVERT ROTARY MOTION INTO PUSH —PULL MOTION. LOCKING RACK & PINION OPERATOR _REVIEWED FOR CODE COMPLIANCE APPROVED MAY - 8 2808 City Of Tukwila BUILDING DI1 ION MOUNT BRACKET INSIDE PLENUM BOX FOR ACCESS THROUGH SLOT REMOTE DAMPER OPERATOR, VERTICAL DIFFUSER MO.3 N.T.S. Valerio Architects Architecture, Design & Planning DATE: Apr 25, 2008 OAKLEY 556 SOUTHCENTER MALL TUKWILA, WA 98188 A Date DESCRIPTION 4/26/08 REVIEW SET 4/28/08 PERMIT/BID/LL REVIEW SET Date Modified: Date Created: Scale: Project No.: Drawn By: CAD File: 5858 Wilshire Blvd, Ste 203 Los Angeles, CA 90036 Telephone: 323.954.E996 Facsimile: 323.954.8965 url: www.valerioarchitects.corn Email: info@valetioarchitects.com CONSULTANT ENCON 4 ENERGY • CONSERVATION • COMPANY 720 Sunrise Ave, Suite 208B Roseville, CA 95661 tel # (916) 772 -8440 fax # (916) 772 -8441 f ,com Copyright © ENCON 2008 ENCON email Projec # : @encon 0K6118.00 [EXPIRES 11 /6 f O PROJECT This document contains Information proprietary to the Architect and Is furnished in confidence for the limited perupose of evaluation, bidding or review. This document or its contents may not be used for any other purpose and may not be reproduced or disclosed to others withoutthe priorwritlen consent of the Architect. RECE V Mechanical Details APR 3 0 2008 PERMIT CENT 4/25/08 4/15/08 AS SHOWN 586 -08 -29 BMS /RDM ENCON 40181.00 VESTIBULE 10' -0 "H. (CLOD SOFFIT 11' -0 "H. l E:) RETURN AIR CP:NINI IN DEMISING WALL, TO RF. MAIN • SOFFIT 11'_0 "H. (CLG1) DROP CEILING 12' -6 "H. (CLG1) 02 OFFICE 10' -0 "H. (CLGI) 4 T N TT DRESSING ROOM 215 0 SOFF T 137H. LL - PK-'A J I6" '�" S `? iie3(: ?U 1 Z (N) 12 "e MED. P3 SSURE DUCT VAV -1® LL- PROVIDED f, ,/, EXHAIJ`;i : TUEOU n 215 LQi •IAUST 1 r 2/11 5 8 "x 14" LQ__J sz 215 1O ;• (E) 215 215 215 . STOCKROOM 18"x14" ENTRY SOFFIT 10' -0 "H. M1) M2.1 7 GENERAL NOTES: SOFFIT 11' -0 "H. LGa1 SOFFIT 11' -0 "H. (CLGI) I l`I ?N AIR OPENING / IN ()FUSING WALL, 10 REMAiN SOFF T 11' -0 "H. (CLGI) rrii SALES AREA 17' -6 "H. __EXPOSED CFIL._ Mechanical HVAC Floor Plan SCALE: 1/4" = 1'-0" 1. MECHANICAL CONTRACTOR SHALL INSTALL ALL DUCTWORK TIGHT TO STRUCTURE TO MAINTAIN REQUIRED CLEARANCES ABOVE CEILING FOR NEW LIGHT FIXTURES. CONTACT THE CONSTRUCTION MANAGER IMMEDIATELY IF CEILING CONFLICTS ARE ENCOUNTERED. 2. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH ALL FEDERAL, STATE AND LOCAL CODES AND ORDINANCES. 3. FLEXIBLE INSULATED DUCTS SHALL BE MAXIMUM 6' -0" LONG AND SHALL MEET INSTALLATION AND MATERIAL REQUIREMENTS OF LOCAL CODES. 4. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF ALL TRADES, LANDLORD REQUIREMENTS, CEILING HEIGHTS AND EXISTING STRUCTURAL CONDITIONS PRIOR TO FABRICATION OF ANY DUCTWORK OR ORDERING OF ANY EQUIPMENT. 5. MECHANICAL CONTRACTOR TO PROVIDE TENANT WITH AS -BUILT DRAWINGS, ALL EQUIPMENT SHOP DRAWINGS, INFORMATION ON THERMOSTATS, CONTROL WIRING DIAGRAMS AND OTHER PERTINENT INFORMATION AT COMPLETION OF PROJECT. 6. ALL BRANCH TAKEOFFS SHALL BE PROVIDED WITH MANUAL BALANCING DAMPERS ABOVE TILE CEILINGS. 7. PROVIDE TRANSITIONS AT EQUIPMENT AND AIR DEVICES TO MATCH CONNECTION SIZES. 8. MECHANICAL CONTRACTOR SHALL PROVIDE OWNER/ENGINEER WITH AIR BALANCE REPORT. 9. MECHANICAL CONTRACTOR SHALL PERFORM A PRE- CONSTRUCTION CHECK OF EQUIPMENT WITHIN THE SCOPE OF WORK. ANY DISCREPANCIES SHALL BE SUBMITTED IN WRITING TO THE GENERAL CONTRACTOR'S SUPERINTENDENT, ARCHITECT, AND MECHANICAL ENGINEER SO THAT CONDITIONS CAN BE VERIFIED AND CORRECTED. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WORK AND REPAIRS NOT NOTED DURING PRE - CONSTRUCTION INSPECTION O UNDERCUT OFFICE DOOR 1 ". V ALL SALES AREA SA GRILLES SHALL BE DIRECTLY MOUNTED TO DUCT. NO "EXTENDED TAP" BOXES SHALL BE INSTALLED. O FIELD VERIFY ALL CLEARANCES ABOVE CEILING SPACE TO MAKE SURE THERE IS ENOUGH SPACE FOR DUCTWORK PRIOR TO DUCTWORK FABRICATION. DUCTWORK FABRICATED PRIOR TO CLEARANCE VERIFICATIONS SHALL BE AT THE CONTRACTOR'S SOLE EXPENSE IF RE— SIZING IS REQUIRED. KEYED SHEET NOTES: 12.cPw NOTE: Refer to Architectural drawings for all fixture locations. Architectural plans always take precedence over those shown on MEP plans. MEP plans are for technical information only. REVIEWED FOR CODE COMPLIANCE APPROVED MAY ' 8 20IVI City Of Tukwii BUILDING DPa /TSTON Valerio Architects Architecture, Design & Planning DATE: Apr 25, 2008 Date Modified: Date Created: Scale: Project No.: Drawn By: CAD File: 5858 Wilshire Blvd, Ste 203 Los Angeles, CA 90036 Telephone: 323.954.8996 Facsimile: 323.954.8965 url: www.valerioarchitects.com Email: info@valerioarchitects.com CONSULTANT ENCON ENERGY Is CONSERVATION • COMPANY 720 Sunrise Ave, Suite 208B Roseville, CA 95661 tel # (916) 772 -8440 fax # (916) 772 -8441 email info@encon.com Copyright © ENCON 2008 ENCON Project #:0K6118.00 EH PROJECT OAKLEY 556 SOUTHCENTER MALL TUKWILA, WA 98188 Date DESCRIPTION 4/26/08 REVIEW SET 4/28/08 PERMIT /BID /LL REVIEW SET This document contains information proprietary to the Architect and is furnished in confidence for the limited perupose of evaluation, bidding or review. This document or its contents may not be used for any other purpose and may not be reproduced or disclosed to others without the prior written consent of the Architect DECEIVE; Mechanical APR 3 0 2008 HVAC PERMIT CENTER Floor Plan BMS /RDM ENCON OK6181.00 4/25/08 4/15/08 AS SHOWN 586 -08 -29