Loading...
HomeMy WebLinkAboutPermit M08-135 - WESTFIELD SOUTHCENTER MALL - BEN BRIDGEBEN BRIDGE 81 S OUTH CENTER MALL M08 -135 Parcel No.: 2623049023 Address: Suite No: 81 SOUTHCENTER MALL TUKW Tenant: Name: BEN BRIDGE Address: 81 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: MARCIA PEDDICORD Address: 633 SOUTHCENTER MALL, TRAILER #3 , TUKWILA WA Contractor: Name: MERIT MECHANICAL INC. Address: PO BOX 2109 , REDMOND, WA Contractor License No: MERITMI163CM DESCRIPTION OF WORK: MECHANICAL WORK FOR TENANT REMODEL Value of Mechanical: $18,000.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC-10/06 CitOof Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT EOUIPMENT TYPE AND QUANTITY 0 0 0 0 0 2 0 0 0 0 0 0 0 0 * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 802 -6071 Phone: 425 883 -9224 Expiration Date: 06/01/2009 M08 -135 08/13/2008 02/09/2009 Fees Collected: $372.50 International Mechanical Code Edition: 2006 Boiler Compressor: 0-3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP/1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment M08 -135 Printed: 08 -13 -2008 Permit Center Authorized Signature: / Date: D/ (1 ?7 I hereby certify that I have read and x ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie • wi , whether specified herein or not. The granting of construction or Signature: Print Name: doc: IMC -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • Permit Number: M08 -135 Issue Date: 08/13/2008 Permit Expires On: 02/09/2009 't does not pres iikto give authority to violate or cancel the provisions of any other state or local laws regulating ormance of work. r., authorized to sign and obtain this mechanical permit. Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M08 - 135 Printed: 08-13 -2008 Parcel No.: 2623049023 Address: 81 SOUTHCENTER MALL TUKW Suite No: Tenant: BEN BRIDGE 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 5: Readily accessible access to roof mounted equipment is required. PERMIT CONDITIONS • Permit Number: M08 -135 Status: ISSUED Applied Date: 05/06/2008 Issue Date: 08/13/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431- 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 15: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the doc: Cond -10/06 M08 -135 Printed: 08-13 -2008 ' 0 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 16: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 17: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 18: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 19: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 20: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 21: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 22: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 23: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond - 10/06 * *continued on next page ** M08 -135 Printed: 08-13 -2008 construction or th= pe ormance of wo r doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us • I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this • en does not presume to give authority to violate or cancel the provision of any other work or local laws regulating I I • Signature: I — ��_- 1 I Date: Print Name: M08 -135 Printed: 08-13 -2008 • CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hitp://www.ci.tulcwilawa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Site Address: 8 1 VO N Ade e,4 4v Mod/ Tenant Name: Y Property Owners Name: e -Q'7` 2 L�,��. d"7 P rtY / Mailing Address: L/ a/ Id /Shire t j /d // 1 LAS Cit CONTACT PERSON; = whodo we contact when your permit is ready to be issued Name: G .✓c .� ? ?d Mailing Address: 401 5 4 0 4 4 , l rep.; /4., 16 3 Day Telephone: cs?C'af - #c L- 44.7 Se. the.._ ,l..)A- 5 8 � / City State Zip " E -Mail Address:Th( d ri c :re-4€ lJ40 . 4.ere Fax Number: GENERAL CONTRACTOR = ( Contractor Information for Mechanical 4) for .Plumbing - and Gas Piping (pg 5)) Company Name: Company Name: Company Name: Mailing Address: Mailing Address: City Day Telephone: Fax Number: Expiration Date: Contact Person: E -Mail Address: Contractor Registration Number: ARCHITECT OF RECORD - Al plans must be wet stamped by Architect of Record D4tl;d A. Udke LIJ Mailing Address: it ikt P L( 3' L1.14 ' Contact Person: D4.0 1 K . kD t E -Mail Address: d j /..tc/icrwa Q Ca x.. ne " ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record mh Rte'/ 75d 8rda / S Contact Person: 5)7 141 41 a sh, A • rho r D E -Mail Address: / Q: Applicarions \Fours- Applications On Line -2006 - Permit Application ds c Revised: 9 -2006 bh Building Permit No Mechanical Permit,No: .Plumbing /Gas Permit No Public Works Permit N. :Project No.` ice drily) • King Co Assessor's Tax No.: 02 4.2, Sag- Suite Number: New Tenant: ❑ Yes State Floor: Zip 3601'1.5dcle Az �l sass P� r . t 8(v1 1_ W deeV, IC. City Day Telephone: Fax Number: state Zip City State Zip � Day Telephone: ii - • 4.d-- 3 igS" Fax Number: *i - /o 1 tL- C 20? State Zip G��-- S 2323 4 14 -- kik- 2337 Page I of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace > WOK: BTU, °._ - - Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig /Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm/lnd • w MECHANICAL PERM TT INFORMATION = 206 - 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $ Scope of Work (please provide detailed information): 747.r va 1.t Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ❑ Replacement ...R Fuel Type: Electric.. Gas ....0 Other: Indicate type of mechanical work being installed and the quantity below: Q: Applications\ Fomu - Applications Ou Line3 -2006 - Permit Application.dnc Revised: 9 -2006 bh Page 4 of 6 Date Application Accepted: PERMIT APPLICATION NOTES — Applicable to 'all ,permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDIN AUTHO GENT: Signature: Print Name: 1 ! i / 0 D tGO O c Day // Telephone: �� —80 - • 7/ Mailing Address: 4,33 �� c �... f=,. T/�t ; / -v 3 cSee.Ti f c_ 4)4 q?/$4 City state Zip Q:t ApplicationslomtsApplications Ou L6e`3 -2006 - Pemut Apphcation.doc Revised: 9 -2006 bh Date Application Expires: t Gob Date: Staff Initials: Page 6 of 6 RECEIPT NO: R08 -02922 Initials: JEM User ID: 1165 SET ID: 0813 SET TRANSACTIONS: Set Member Amount ACCOUNT ITEM LIST: Description City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us Payee: MERIT MECHANICAL, INC. ELOS -1113 58.00 MOB 35 298.00 TOTAL: 356.00 ELECTRICAL PERMIT - NONR MECHANICAL - NONRES SET RECEIPT Account Code Current Pmts 000.322.101.00.0 58.00 000.322.102.00.0 298.00 TOTAL: 356.00 6f7 r Payment Date: 08/13/2008 Total Payment: 356.00 SET NAME: MERIT MECHANICAL TRANSACTION LIST: Type Method Description Amount Payment Check 23811 356.00 TOTAL: 356.00 Doc: RECSETS -06 RECEIPT NO: R08 -01497 Initials: JEM Payment Date: 05/06/2008 User ID: 1165 Payee: THE KLINKHAM COMPANY SET ID: S000001025 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http : / /www. ci. tukwila. wa. us EL08 -524 102.50 M10A8;;2 37 74.50 TOTAL: 177.00 SET RECEIPT • Total Payment: 177.00 TRANSACTION LIST: Type Method Description Amount Payment Check 4680 177.00 TOTAL: 177.00 ACCOUNT ITEM LIST: Description ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES Account Code Current Pmts 000.345.832.00.0 102.50 000/345.830 74.50 TOTAL: 177.00 2055 05/06 9711 TOTAL 177.00 Projset4,1 (� ki 2rfr'N,1L Type of Inspection: Address: I( A ti d\vi- kc�o� )t,r V_l1 Date Called: A ( 1 Special Instructions: e Requester: Date Wanted: I (--/ -- ® � a.m Phone 0 Lif INSPECTION RECORD Retain a copy with permit PIOG _( INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3q7 17\pproved per applicable Odes. El Corrections required prior to approval. / COMMENTS: (4 rtA;-k- tE-' • e or: t .4,0 L i4 Alt Date: 10 19 Co' 60.00 REINSPECT! • FEE REQUIRED. Prior to.ihspection, fee must be aid at 6300 Southcent =r Blvd., Suite 100. Call to schedule reinspection. . Rec ipt No.: 1Date: Projec I PAJ 3r. ,�GL Type of Inspection: 5a, a/o-� D e fr oaf Address: Date Called: Special Instructions: i t ?_ 0 31 -v/ i Date Wanted: / O ".3")& p.m. Requester: Phone No: 6) 7 &- 4s I ---4 INSPECTION RECORD Retain a copy with permit PERMIT NO. MoV -135, INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367.0 X Approved per applicable codes. 0 Corrections required prior to approval. 4 COMMENTS: g ‘e14.0 leg071 o of. A.v1 1441 74"'9' J Inspector: k Dat / 17$60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. • Pro ' o� Q- r�c� Type of Inspection: ~ti- 1 Add s: ,,�� Mill tv`� , Date Called: • Special Instructions: • Date Wanted: 9 -76f-of ff., Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION . 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ID Approved per applicable codes. s, Corrections required prior to approval. ` I� - C� 60 REINSPEC ION FEE R UIRED Prior to inspection, fee must be -:a t 6300 Southcenter Blv ., Suite 1 0. Call to schedule reinspection. Rece _ No.: 'Date: • froe -r5S sec , 1 /� / J �p Pro & I; k ei/cr y C Type f I � (C H Z /U Address: / � Date Called: . Special Instructions: p Date nted / a /� a. P . m . Requester: PnG'7234 25 I X71: �.. m48•85 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION r"" 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ❑ Approved per applicable codes. ID Corrections required prior to approval. COMMENTS: (,) • �� 1 &) ;,e -RJ - I'0 -L.QuANJ 6k TO _ -jupa e _ $4.00 REINSPECT! N FEE QUIRED. Prior to inspection, fee must be id at 6300 Southcenter Bl d., Suite 100. Call to schedule reinspection. Receipt No.: !Date: , COMMENTS: Type of Inspection: r4 /rn Address: g / ,5- Suite #: �51 - ) a t nl K P- ,Vil C.. --- 0 Phone No.: Monitor: 4--t 46 47/e -i •i (-- ; f,q C. - 0/4, -- e AN Pre -Fire: Permits: /11/ r ,._ri; 4 -,i1 -- 0 IL 7 °— s 121 ,(---/ !1/t''L- - /9k-- -/: 4 ` . - --- Q Project: jv r E Type of Inspection: r4 /rn Address: g / ,5- Suite #: 41 ,..„_ Conta erson: r� - � - T - Special Instructions: Phone No.: Needs Shift Inspection: Sprinklers: Y Fire Alarm: fI Hood & Duct: ./ Monitor: C 4, h //vpv Aide 'v4_ Pre -Fire: Permits: Occupancy Type: 7 INSPECTION NUMBER VI --- per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT Word /Inspection Record Form.Doc 1/13/06 PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Corrections required prior to approval. Inspector: fi j A 512- Date: 0/ . it 5 . Hrs.: $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from he City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 Cooling Equipment Schedule Equip. ID Brand Name' Model No.' Capacity Btu/h Total CFM OSA CFM or Econo? SEER or EER IPLV Location l r° CA 6g 5N-13czoo4 3(0,o0o l2a EC 4o, l3o I J/A iof -4 U • � LA l 0 6 2018 • _..a Fan Equipment Schedule 'mg ' �_' ^' ' 's'/ F t - '1 ; SP " ' I. Flow Control Location of Service Equip ID Brand Name' .- Model No.' CFM MAY 1 2 zo ;', Project Info Project Address 5 M Date 3 _j 3 _ 6)2 9'l 560 TN Ca t d' e p G 6 m4 // For Building Dept. Use n Tithe; to - Gi'v 2 , Applicant Name: B el 3 f pGe \ tv � LEQ t� 1 ✓i- c� G`�J Applicant Address: Applicant Phone: Heating Equipment Schedule Equip. ID Brand Name' Capacity Model No.' Btu/h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency" ' -:i. E. ` 5o NsQo 0 :. • c /Zoo 6Ca . HEM a t i i -4 U • � LA l 0 6 2018 • _..a Fan Equipment Schedule 'mg ' �_' ^' ' 's'/ F t - '1 ; SP " ' I. Flow Control Location of Service Equip ID Brand Name' .- Model No.' CFM MAY 1 2 zo ;', ; I. CITY OF TUKWILA - BUILDING DIVISION 2006 Washington State Nonresidential Energy Code Compliance Form Mechamcal'Summa CH -SUM. 2006 Washington Stale Nonresidential Energy Code Compliance Forms Project Description Briefly describe mechanical system type and features- fides Plans r Compliance Option Equipment Schedules Pt—rgiit No. FILE COPY Include locumentatinn.reggiOng compliancewi with onimisilning equire Simple System 0 Complex System J 0' =5ystert�l r5 • (See Decision Flowchart (over) for qualifications. Use separate ME The following information is required to be incorporated with the ro}i+�al plans. For projects without plans, fill in the required information\ k 4 Revised July 2007 systems.) schedules on the " T ec apical Permit Plans 2006 Washington State Nonresidential Energy Code Compliance Forms ECH-CHK Revised July 2007 :Ch ecklist r Project Address 8 T3Cr E S6r�6 �eg5 633 Socl A CENT-E,K. Date 3 -/ 5-6R The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes. no, n.a) Code Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance '-i640 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule tMt Ito `1.6S 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency 5o t Nth 1411.1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket loss 1 ► /A �FJ 1412 HVAC controls N >y 5 1412.1 Temperature zones Indicate locations on plans M i01 `l 1412.2 Deadband control Indicate 5 degree deadband minimum M 1ot N /1k 1412.3 Humidity control Indicate humidistat /& e-- 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types '„t t• et \/E---.S 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage M t,01 N/A 1412.4.2 Optimum Start Indicate optimum start controls /4(A 1412.5 Heat pump control Indicate microprocessor on thermostat schedule i 1ik ri � 14 Combustion htg. Indicate modulating or staged control 1412.7 Balancing Indicate balancing features on plans 1412.8 Ventilation Control Indicate demand control ventilation for high - occupancy areas �£ G, 1422 Thermostat interlock Indicate thermostat interlock on plans _I t t eS 1423 Economizers Equipment schedule h6-0( 1413 Alr economizers tip 1413.1 Air Econo Operation Indicate 100% capability on schedule /15ot N A 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb 1413.2 Water Econo Doc Indicate cig load & water econoe & clg tower performance ell: 1413.3 Integrated operation Indicate capability for partial cooling t // P6/ 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems i_.ES 1414.1 Duct sealing Indicate sealing necessary 11511 "Nt*C- 1414.2 Duct insulation Indicate R -value of insulation on duct H5 1 6 N /1c 1415.1 Piping insulation Indicate R -value of insulation on piping WA 1416 Completion Requirements 1416.2.1 Commissioning Provide commissioning plan 1416.2.2 -3 Sys.Bal & Func.Test Indicate air and water system balancing & functional testing t 1416.2.4 Commissioning Indicate O&M manuals, record drawings, staff training 1416.2.5 Comm. Report indicate requirements for prelim. & final commissioning report j r A '..' 1434 Separate air sys. Indicate separate systems on plans i dit t CE S Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer )1644 (,T SERVICE WA I ER HtATINV AND HEATED POOLS (Sections 1440 -1454) 1.(A 1440 Service water htg. 1441 Elec. water heater Indicate R -10 insulation under tank NIA `� / ` 1442 Shut -off controls Indicate automatic shut -off 1443 Pipe Insulation Indicate R -value of insulation on piping 1452 Heat Pump COP Indicate minimum COP of 4.0 1452 Heater Efficiency Indicate pool heater efficiency 1453 Pool heater controls Indicate switch and 65 degree control 2006 Washin! ton State Nonresidential Ene Code Com•liance Form ACTIVITY NUMBER: M08 - 135 DATE: 05 - - PROJECT NAME: BEN BRIDGE SITE ADDRESS: 81 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: 41.. - B i iI,i ng 1'vision IY Public Works ❑ DETERMINAT ON OF COMPLETENESS: (Tues., Thurs.) iv Complete Comments: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Fj Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 PERMIT COuu • PLAN REVIEW /ROUTING SLIP Structural Fire Prevention Planning Division Incomplete Structural Review Required n DUE DATE: 05-08-08 Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DATE: DUE DATE: 06 -05-08 Not Approved (attach comments) n DATE: Permit Coordinator Not Applicable n n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Name Role Effective Date Expiration Date KIRKWOOD, RODERICK V PRESIDENT 02/14/1984 Bond Amount KIRKWOOD, JOAN M SECRETARY 02/27/2006 0815103546895BCM07/22/2001 FRICKBERG, WILLIAM MICHAEL VICE PRESIDENT 02/27/2006 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 8 TRAVELERS CAS It SURETY CO 0815103546895BCM07/22/2001 Until Cancelled $12,000.00 03/07/2002 7 TRAVELERS CAS Et SURETY CO 081S103546895BCMO2/01/2001 07/22/2001 $6,000.00 06/29/2001 6 UNITED PACIFIC INS CO 2473230 02/01/1998 Until Cancelled 02/01/2001 $6,000.00 5 UNITED PACIFIC INS CO 2473230 02/01/199402/01 /1998 $6,000.00 4 PLANET P484339 02/01/1992 02/01/1994 $6,000.00 3 PLANET INS CO P484339 02/01/198702/01 /1992 $6,000.00 Untitled Page General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. MERIT MECHANICAL INC Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company MERIT MECHANICAL INC 4258839224 PO BOX 2109 REDMOND WA 980732109 KING CORPORATION UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Separation Date Previous License Next License Associated License Specialty 1 Specialty 2 600517946 ACTIVE MERITMI163CM CONSTRUCTION CONTRACTOR 2/14/1984 6/1/2009 AUTOMMC044QH GENERAL UNUSED Business Owner Information Bond Information • Page 1 of 2 https: // fortress. wa. gov /lni/bbip/Detail.aspx ?License= MERITMI163CM 08/13/2008 Q EMr e SALES AREA 1 5 MECHANICAL PLAN 1/4 " =1' -O" MECHANICAL GENERAL NOTES CONICAL BELLMOUTH FITTINGS WITH MANUAL BALANCING DAMPER TO BE USED FOR ALL ROUND BRANCH TAPS ABOVE ACCESSIBLE LAY—IN CEILINGS. CONICAL BELLMOUTH FITTINGS WITHOUT MANUAL BALANt.;ING DAMPERS TO BE USED FOR ALL ROUND BRANCH TAPS ABOVE INACCESSIBLE DRYWALL CEILINGS WITH BALANCING REQUIRED WITHIN 2 FT. OF DIFFUSER WITH PLASTER FRAME. 2 ROUND RIGID SUPPLY, RETURN AND RELIEF AIR DUCTS SHALL BE EXTERNALLY INSULATED WITH 1" THICK, 1.5 LBS. DENSITY, FOIL FACED FIBERGLASS INSULATION. FLEX CONNECTIONS TO DIFFUSERS ARE INSULATED FLEX WITH A MAXIMUM LENGTH OF 5 FT. 3 MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF ALL TRADES, LANDLORD REQUIREMENTS, CEILING HEIGHTS AND EXISTING STRUCTURAL CONDITIONS PRIOR TO FABRICATION OF ANY DUCTWORK OR ORDERING OF ANY EQUIPMENT. 4 THE HVAC CONTRACTOR IS RESPONSIBLE FOR COORDINATING BOX —OUT LOCATIONS FOR ALL DRYWALL MOUNTED AIR DEVICES WITH GENERAL CONTRACTOR AND CEILING FRAMING. MECHANICAL CONTRACTOR TO PROVIDE TENANT WITH AS—BUILT DRAWINGS, ALL EQUIPMENT SHOP DRAWINGS, INFORMATION ON THERMOSTATS, CONTROL WIRING DIAGRAMS AND OTHER PERTINENT INFORMATION AT COMPLETION OF PROJECT. 6 THE CONTRACTOR FOR THIS DIVISION OF WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF ALL SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT IS THIS CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL SUB CONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 7 THE MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL STRUCTURAL STEEL REQUIRED TO SUPPORT ANY MECHANICAL EQUIPMENT. THIS CONTRACTOR SHALL COORDINATE LOCATIONS AND REQUIREMENTS WITH THE GENERAL CONTRACTOR AND LANDLORD PRIOR TO BID. 8 FIRE PROTECTION PLANS (SPRINKLER DRAWINGS) MUST BE ENGINEERED AND WET SEALED BY A LANDLORD APPROVED, LICENSED REGISTERED FIRE PROTECTION CONTRACTOR IN THE LOCAL JURISDICTION. NOTE: ALL ROOFING WORK IS TO BE PERFORMED BY THE LANDLORD'S CONTRACTOR AT TENANTS CONTRACTOR'S EXPENSE, IN ORDER TO MAINTAIN THE WARRANTY AND THE INTEGRITY OF -NE ROOF SYSTEM PRIOR TO BID SUBMITTAL, Q MECHANICAL CODED NOTES EXISTING THERMOSTAT FOR RTU, AND ASSOCIATED WIRING, ETC. TO BE RELOCATED AS SHOWN ON PLANS. INSPECT ALL THERMOSTATS FOR PROPER WORKING ORDER, CLEAN, CALIBRATE AND REPLACE IF REQUIRED. RTU -1 EXISTING ELECTRIC COOLING HEAT PUMP ROOFTOP HVAC UNIT IS TO BE REUSED. CLEAN AND ADJUST EXISTING ROOFTOP UNIT. CHEMICALLY CLEAN COILS, PERFORM OIL SAMPLE TEST ON COMPRESSORS TO VERIFY CONDITION, REPLACE BELTS, VERIFY ECONOMIZER CONTROLS ARE FUNCTIONAL AND MAKE SURE ALL EQUIPMENT IS IN PROPER OPERATING CONDITION. REPLACE ANY DEFECTIVE PARTS OR EQUIPMENT. GREASE AND /OR REPLACE IF REQUIRED FAN BEARINGS, CHECK SHAFT FOR SCORING, CHECK MOTORS FOR PROPER AMPERAGE DRAW. CLEAN OR REPLACE CONDENSATE DRAIN LINE AS REQUIRED. REBALANCE FANS TO CFM'S SHOWN ON PLANS. FURNISH UNIT WITH THREE SETS OF STANDARD FILTERS. CONTRACTOR TO REPLACE FILTERS JUST PRIOR TO AIR BALANCE AND ONCE AGAIN AFTER FINAL STORE CLEANING IS COMPLETE. EXISTING PLUMBING FIXTURES, EXHAUST SYSTEM, TRIM, PIPING, WATER HEATER ETC. TO REMAIN, CLEAN ALL FIXTURES AND LEAVE IN LKE —NEW CONDITION. REPLACE TOILET BALLCOCK AND VERIFY PROPER OPERATION OF EXHAUST FAN AND WATER HEATER AND REPLACE IF REQUIRED. EXISTING AIR DEVICE TO BE REUSED AT EXISTING LOCATION. THE MECHANICAL CONTRACTOR TO CLEAN GRILLE AS NEEDED. ENSURE THAT FLEX DUCT IS NOT KINKED OR FOLDED. PAINT IF REQUIRED. REBALANCE AIRFLOW TO CFM INDICATED. EXISTING DUCTWORK SHALL BE REUSED, VERIFY EXACT SIZE AND LOCATION IN THE FIELD PRIOR TO BID. 0 0 FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. -5 EXISTING DUCT TO REMAIN. (• O R EXISTING PENDANT SPRINKLER HEAD _. TO BE RELOCATED EXISTING CONCEALED SPRINKLER HEAD TO BE RELOCATED (* •E EXISTING PENDANT OR CONCEALED SPRINKLER HEAD TO REMAIN ®N NEW PENDANT SPRINKLER HEAD • N NEW CONCEALED SPRINKLER HEAD R LEGEND EXISTING S/A DIFFUSER TO REMAIN. NEW S/A DIFFUSER. EXISTING R/A GRILLE TO REMAIN. NEW R/A GRILLE. S NEW DUCT. a'EpARATE PERMIT REQUIRED FOR 13 iteichanical f Electrical lambing Gas piping City of Tukwila BUILDING DIVISION VERIFY ALL CONDITIONS IN THE FIELD PRIOR TO BID. SMOKE DETECTOR IN RETURN AIR DUCT TO DE— ENERGIZE RTU SUPPLY FAN IF ACTIVATED. SMOKE DETECTOR TO BE PROVIDED BY ELECTRICAL CONTRACTOR INSTALLED BY MECHANICAL CONTRACTOR. WIRING BY ELECTRICAL CONTRACTOR. _.. REV INNCE CODE COMP City Ot Tuk BUILDING HIV ISION THERMOSTAT LOCATED 48" ABOVE FINISHED FLOOR, FURNISHED AND INSTALLED BY THE MECHANICAL CONTRACTOR. COORDINATE EXACT LOCATION WITH TENANT. MECHANICAL CONTRACTOR SHALL WIRE FROM THE THERMOSTAT TO THE HVAC UNIT. THERMOSTAT SHALL BE INSTALLED PER THE MANUFACTURER'S INSTRUCTIONS. RTU -2: CONTRACTOR TO PROVIDE WHERE SHOWN ON PLANS AND /OR AS DIRECTED BY THE LANDLORD A ROOF MOUNTED HEAT PUMP ROOFTOP HVAC UNIT. ROOFTOP UNIT SHALL INCLUDE INCLUDE A FULL PERIMETER ROOF CURB, COMPLETE ECONOMIZER PACKAGE WITH ALL CONTROLS AND WIRING FACTORY MOUNTED. UNIT SHALL BE FURNISHED WITH TWO SETS OF STANDARD FILTERS. CONTRACTOR TO REPLACE FILTERS PRIOR TO TURNING STORE OVER TO TENANT, PROVIDE UNIT WITH BAROMETRIC RELIEF DAMPER ALL ROOF WORK INVOLVED WITH SETTING OF THE ROOF CURB AND UNIT SHALL BE DONE BY THE LANDLORD'S ROOFING CONTRACTOR AT THE GENERAL CONTRACTOR'S EXPENSE UNLESS NOTED OTHERWISE. GENERAL CONTRACTOR SHALL PROVIDE ANY ADDITIONAL STRUCTURAL STEEL REQUIRED TO SUPPORT RTU PER LANDLORD'S REQUIREMENTS. THE MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL CONDENSATE DRAINS FROM ALL RTU'S AS SHOWN ON PLANS. MINIMUM DRAIN SIZE TO BE 1 OR AS SPECIFIED ON PLANS. CONDENSATE DRAIN TO BE TRAPPED WITH A MINIMUM 5 TRAP DEPTH. DRAINS SHALL BE EXTENDED BY THE TENANT CONTRACTOR AT A SLOPE OF 1" PER 40' TO THE ROOF DRAIN. PROVIDE RETURN AIR OPENING THROUGH THE WALL SEPARATING THE SALES AREA FROM THE NON —SALES AREA. SIZE OPENING AS NOTED. VERIFY ANY RETURN AIR OPENINGS IN SALES AND STOCKROOM WALLS AND ENSURE OPENINGS REMAIN UNOBSTRUCTED AT THE COMPLETION OF CONSTRUCTION. GENERAL REMODELING NOTES ALL DRAWINGS ARE CONCEPTUAL AND SCHEMATIC AND ARE INTENDED FOR USE AS A DESIGN /BUILD GUIDELINE. THE CONTRACTORS ARE RESPONSIBLE FOR VERIFYING ALL FIELD CONDITIONS AND ADJUSTING OR MODIFYING THE SPECIFIC ELEMENTS OF THEIR WORK AS REQUIRED TO MEET THE DESIGN INTENT. THE CONTRACTORS ARE RESPONSIBLE FOR THE FOLLOWING: A COORDINATION WITH OTHER TRADES. B PROVIDING ADDITIONAL DRAWINGS. CALCULATIONS AND OTHER DOCUMENTATION REQUIRED FOR THE BUILDING DEPARTMENT. THE ELECTRICAL CONTRACTOR SHALL DOCUMENT ALL CIRCUITING AND PROVIDE ALL TESTS REQUIRED TO SUBSTANTIATE CODE COMPLIANCE AS REQUIRED BY THE BUILDING DEPARTMENT AND LOCAL INSPECTOR. SUBMIT FINAL AS —BUILT DRAWINGS TO BUILDING DEPARTMENT FOR RECORD AT COMPLETION. THE CONTRACTORS SHALL VISIT THE SITE TO DETERMINE CONDITIONS AFFECTING THE WORK. BIDS SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS AND ANY MODIFICATIONS WHICH ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS. FAILURE TO VISIT THE SITE DOES NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY IN PERFORMANCE OF WORK REQUIRED DUE TO EXISTING CONDITIONS IN EVIDENCE. CONTRACTOR SHALL RECORD, ON A SET OF "AS— BUILTS" DRAWINGS, ALL CHANGES OR MODIFICATIONS MADE IN THE FIELD, TO AN ORIGINAL SET OF CONSTRUCTION DOCUMENTS, FOR TURN —OVER TO THE ARCHITECT /ENGINEER UPON COMPLETION OF THE PROJECT. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH STATE AND LOCAL CODES AND ORDINANCES AND THE NATIONAL ELECTRIC CODE. By Date: FILE COPY Permit No. FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE ! 3CHEMATTC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS ‘:ONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY ;=OR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL, CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS irIADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS !:,TALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCE,: AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK II" STALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE FLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL. ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPII.NCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. Mar review approval is subject to errors and omissions. Approval of construction documents does not authorize the violati • • : fly adopt or ordinance. Receipt of approv =d Fie d Copy and ons is . rL =lodged: E T ,_ -DING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. RECEIVED CITY OF TUKWILA MAY 0 6 2008 PERMIT CENTER U. Te D rawn Chedasd Rebel No.740 Project 9869 I0001 Sand= 0110 watt Wit Witetteed Ina DAVID A. UDKO ARCHITECT TENANT IMPROVEMENTS CONSULTING Emphasis On Excellence M•Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 PHONE 614.818.2323 JOB r�p/� p FAX 614.818.2337 10809008 Working Drawing Review Approved Approved as Noted 0 Resubmit These drawings have been reviewed For general design Intent only. All actual field conditions are required to be verified by the Tenant's Architect and /or Contractor. Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings is required to be kept on the job site fl times. DO NOT SCALE DRAWW4O9. 11881 NORTH 113th WAY SCOTTSDALE, AZ. 85259 (480) 614 -3385 bus (480) 614 -0209 fax email: davidaudkow@cox.net ;t tiarled Date 04/01/08 ISSUED TO LANDLORD 04/01/08 ISSUED TO CLIENT No. Dab Romblon Conbasbr most sway all Job dimembos. drarrlfhg% debt and speolflogAlons and report any dlecreponales b designers bsbre proceeding with work. Waft WM not be Mb for cry anus and anledone not reported by General Corkeclor. BEN BRIDGE JEWELER SOUTH CENTER MALL 81 SOUTHCENTER MALL LEVEL 1, UNIT #740, TUKWILA, WA 98188 MECHANICAL PLAN /13/08 Dab JANUARY 2007 Sc ats AS NOTED Dtwetro Dale • ect ect Dramas Tole drawing not b be treed for oenelruaaon ti corrlierrpned. The =dente al the drawing are the copyright at Wet and ales notes be reproduced in whole or In part without the ahpmee *Oen congeni dtfire *Indul t archer. Walt wit not assume responsibility tor any nso0ert anon or omissions. I ■ • M 101 OF 7 SHEETS T 410.304.9394 800 Bayvlew Avenue F 410.304.1099 Toronto, ON W wettln .a m Grad. M0A 8R7 an Sway Soup Oansaw AIR DEVICE SCHEDULE NOTES 1. SYMBOL KEY — 4. VOLUME. DAMPER — FIRST LETTER: S— SUPPLY R— RETURN E —EXH T— TRANSFER FACTORY FURNISHED. OPPOSED BLADE OR BUTTERFLY SECOND LETTER: D— DIFFUSER R— REGISTER 0— GRILLE WHERE AVAILABLE. ADJUSTABLE FROM FACE. 2. PROVIDE OPIIOAL DIRECTIONAL BLOW FEATURE FOR 5. BORDER STYLE — OTHER THAN 4 —WAY. "A" SURFACE MOUNTED "B" LAY —IN, PROVIDE WITH PLASTER FRAME 3. FINISH— FOR DRYWALL CEILING MOUNTING. "A WHITE. "C" LAY —IN FRAME FOR T —BAR CEILING. "B" WHITE — G.C. TO FIELD PAINT TO MATCH CEILING OR WALL WITH ENAMEL FINISH. 6. PROVIDE BOOT FOR DUCT MOUNTING. SYMBOL MANUFACTURER CATALOG NUMBER NOMINAL SIZE MOUNTING MATERIAL FINISH (3) DPR. (4) BORDER (5) REMARKS MOD. NECK Ito _JO .0 DUCT STEEL ALUM. SD -1 TIS J TMS 24 "x24" 1O "0 • STRUCTURAL AS REQUIRED Rig FOR MU • B aid B SD -2 TM$ 24 "X24" 10 "4 • • B • C MU MIXING BOX MOTOR OPERATED DAMPER ACTUATOR i CONDENSING wins RG -1 TUTUS 355 —RL 24 "x24" 22 "x22" • CURB AND/OR STRUCTURAL SUPPORTS FOR COND. UNITS AS REQUIRED • B B RG -2 355 RL 24 "x24" 22 "x22" • • • • B C ROOF CURB FOR T MIAMI • • STRUCTURAL SUPPORTS FOR RTU AS REQUIRED. • f OUTSIDE DIMENSION ITEM 1 l 23", ", 17" OR 11" INSIDE DIMENSION o- T - - - . MECHANICAL /PLUMBING RESPONSIBILITY SCHEDULE ITEM FURNISHED By INSTALLED BY REUS NjA REMARKS TENANT WOMB corm memo CONTR. E70511NG AR HAMUR° UNnS • STRUCTURAL AS REQUIRED Rig FOR MU i OPERATED AND AI Box IW� • MU MIXING BOX MOTOR OPERATED DAMPER ACTUATOR i CONDENSING wins • CURB AND/OR STRUCTURAL SUPPORTS FOR COND. UNITS AS REQUIRED ROOF TOP UNITS • • i ROOF CURB FOR T MIAMI • • STRUCTURAL SUPPORTS FOR RTU AS REQUIRED. • i i V.A.V. BOXES • DIFFUSERS AND GRILLES • • • DIFFUSERS/CRIMES FIRE DAMPERS • WALL FIRE Cpe ATION DAMPERS MD i • • LOW PRESSURE DUCTWORK • • • HIGH, EDIUM PRESSURE DUCTWORK • TEMPERATURE CONTROL SYSIER • • • REWF AIRJ dAIGE UP AIR MOTtTR lEO DAM PERS • RELIEF MAME AIR MOTOR OPERATED U DAMPER ACUATORS • N R RETURN AR DUCT PONE DAMPERS • DUCT HEATER(S) • UNIT/BASEBONw HEATER(S) RETURN AR FAN • OUTSIDE MR INTAKE HCCO/FAN • RELIEF AR FAN OR HOOD • E7NAUST FANS) i EXHAUST DUCTWORK i AR BALANCE REPORT • AABC CR NEB8 CERTIFIED AS —BULT DRAWINGS • PLUMBING FIXTURES i WATER METER PIPING AND • SPRNKUR PIPING AND HEADS • • • OENER4 NOTE THIS SCHEDULE IS INTENDED AS A 'QUICK' REFERENCE ALL ITEMS USTED HERE ARE SPECIFIED AND DETAILED ON THESE DRAWINGS. IF THE CONTRACTOR ENCOUNTERS ITEMS THAT ARE CONTRADICTORY THEN IT IS HIS RESPONSIBILITY TO INFORM TENANT'S CONSTRUCTION MANAGER SO THAT THESE fEMS CAN BE CLARIFIED FOR THE CONTRACTOR. lbopply Fen 111z1ng Deis. DMZ LOADS Wkndawel 9410 OM Lamb WI.- timemirioEn Float Itenembien Window Tmendethei MAO Ttinembion Door Lao& Flow Trensmfadon PlsTifb = Ogling Ovadned Wets Tied Udine Riede kenden Mhodeneaun Whey Factor str Tart Zane Lade Zane Condlbriin Plenum WdLaid Flamm Roof Leal Plenum LIMN Land Return Fen Land Ventbion Lund eappt► Fim Laid Open Rio Moll Fan. Dud Fret Gin/ Lau I* Tort grim Lauds Canind Owing Cd Catr.l Hogan Cal sts TatW Canilleing Design Panunstens: Old► Nein ....de.. •........... •••••••........EM•■• ..... wilt IIAP bombe Mal.M.M .........rA..... sees.. :.,-. Waelimirei — ......__.... -. ..._..:......._ 4T.S Dp. . ....: ..rA..r- ............... ...... r- ...._..e....._..,......111.11•1121111•011.. E1SISSa .....emoessm ■•••.... . ,,. ..v.....1...,,... 444.0 2 Sumner Design DCr -Bub .. ......... i.∎ ......................r,...NMEN .................. DLO IF smrnsr Coinddert Wet—Deb sees ................® .. ........ IA 'F gummy Cody Renee ..... .�.......... ............ .........,,,,�..._ .n...,. ..-.._s Wider Di -Bub .sees.. ...................■1111.MON see41..MMMI_ ne 'F WMerDudg Wit - Dub ... ...........A.......••110.m....... ... rA..- ....�..... ...............- . �.... 1st 'F Ab neepinede Gle n ote Number .a..v......e ..vdd........ ■...e-. -.... 1.55 Average Qourrd RsIsoMgs -. ..® • S ol m..,.R_....._._.......... IMMOMMINNIMMENIMI a_ OA S K B 'F) N hours) exer.) n....,,_......�.... - ... ..........:....._..a...... sees Tine .�..�......v.�..... ,.,.... ..._„� ®.MV...... YOB • Daylight .M. D light ` e v i Boo .................® �-... .....eMd� 8ine rilibo WewlhsrDeiO ................ , ....... ...n..e....:..,............__.. ..... nun.*w rent Darr . ......,....._— .........a..A. — 2001 ASHRAM limidboOk D selbn Oosbi0 MNxa59s .. ..sees ..sees.. ••••••••.•,••••••••••••• .nary to Decombe r Air Worn beonostion Ak *ism 55J Oaf Clr Equipment Cbge adrm ._._____ -. _boaZCAV ALf Zeriei Zane CFA . Wee of epees. lbw rine Spas CFA krdly . -. peek epee loads (Word Cooing QM INN lists T ali ad bed •••••.. _.,,.. ---- 7• Tian Tlot.l ad load . • 333 MOH Emelbie ad load ----- !9a Melt Cd CFA et.km 000 ■■..,.,...___. - 1 G Mira[ bleak CFA •••■•••..•-,.. • 1215 CFM m San of peeks CFA _ ....�� 1215 GRA Dmeible hid robo --___. 5.851! Mee .. VOA I � II, �� _.,.......- . -....._.— ..... -. •= . . •..--- sees - -� Wierbaer • 10.0'F rr..-- — WA Cmtarl Healing Coot Diable She ad teed . sees.. -... 1a 5 MOH Cal CA Dw F14 sees. _.,.., -..__ . .8.8.85 C RA A■c ad CF . . 1705 C FA Yllf rAoM/400..0'Fth p AGSM nn■c CFA ....=a-. .,`.- •..MY11•••• 127N C FA /dud mec CRIMP . _-_ ...-� . 1.42 CFAI! OaddeerVentilailon At Delta MienaeltBOwCFA ..,.__.... 725 c131 .. -.-- LIM CRAW sainName ampl..mmumoi ...- _ra._.._ Oeteber, 31 Numbered zones ::. --.-. Lamm libbs•MMONMEBEWMONIONes SUM Wintangkin alinialin Mlads .N■:.......- . : �... -.-- -- e- naboid.d Mow Dn>i Laid mum at .-- - Ant INS OA DL! /Wit WSW. 55.5154.8 'F LMtwit n DBMS WS ..- ,.�._.- sees -.- .. , 55 'F Lining DS / WO . — mlns 'F Dimes Fedor ...MIMM.. -..■ .••■■• 5.155 R.. m RH .,— 01 S Chip Dew T C� ... ...,�.�,.. 1 II OK Wyman. dws dmII 1 .—.... 11.5 'F Leal cssss at . ••••-. Ole H `4 •— . .*g•WO.,- .____. 14. Et& LM / LMS DO . . ..,..., 51.5171.8 'F Fan M r IFP .We.eeD.B ..._ ......01 11 115 DIP Fan motor IN .. - .r.., -.. es Wlv CIROPINON •• •• 2435 CRIVestslwl DIM 0000IO DEMI MAIM IM COOLING DATA ATJan INS MATINS DATA AT DID WO WOUND OAD0 /MIO U5T /M`5'F IliAUSOAD5{IW I 226 V/122'F Nn.ble Likud Derr (=R s) (011,181r) Dort. 0 r 0 - or - 0! 0 - or 0 In 7210 - WO 4cs or 0 - Or d 0 1F 0 - or 0 or 0 - or R 1170 0 - nor o or o - or o or 0 - or 0 2405W One - 0 0 1710 W 4595 - 0 0 1100W 4919 - 0 0 a 1721 1907 0 0 - 0 0 - 0 - 0 0 0 105 / 10% 1005 191 10% CA - WM 1557 - 8118 - 70232 1997 - KW 0% 0 - 0 0 70% 0100 - 0 0 30% WIN - 0 0 1238 CFA 0 - 1230 CFA 0 220 CFA 719 490 WO ORA 108'.13 1290 CFA 3003 - 1220 CFA ,37933 0 0 o% 0 a% 0 91714 1515 - ISM - 31714 1000 0 - 0 - 1N4'2 - $1714 105 - ups pawn mime we eV Used. Poeilhe mime ale Ir4 rode N.aotivw Neuss me kite loads Uegdlve Minn my di rode Ileosele Lame ATt ., (B ) 0 0 0 0 5 0 0 5 0 5 25 1/4", 21 1/4', 19 1 /4" OR 13 1 /4" 24 ", 20 ", 18" OR 12" NOTE: ROUGH —IN OPENING SIZES: NOMINAL 12 "x 12" = 12 1/2 "x 12 1/2" NOMINAL 24 "x 24" = 24 1/2"x 24 1/2" NOMINAL 24 "x 12" = 24 1/2 "x 12 1/2" NOMINAL 18 "x 18" = 18 1/2 "x 18 1/2" NOMINAL 20 "x 20" = 20 1/2"x 20 1/2" 25 1/4", 21 1/4", 19 1/4" OR 13 1/4" 1 1/2- 1 1/8- DRYWALL MOUNTING FRAME DETAIL NTS "C" CHANNEL REINFORCING BY G.C. AROUND OPENING MOUNTING SCREW FIELD INSTALLED DRYWALL CEILING STEEL MOUNTING FRAME 1 RTU -1 UNIT NUMBER NEW HVAC ROOFTOP MANUFACTURE/ MODEL # CARRIER 50HJQ004 0 Z I- 3.0 w LAJ cn 1.2 1200 13.1 BHP FAN P SP z E .50" NOTE: 1. Units shall be hi— efficiency, SEER 2. Provide the following factory insta — Through the base electric conne - Unit main power disconnect swi — Field powered convenience outle Hinged access doors. — Vertical Discharge. — Dual enthalpy Economizer 3. Provide the following field installe — Knockdown roofcurb. — Barometric Relief Damper — Programmable night setback th 4. Start —up and one year labor warr RPM 1270 as shown in schedule. Iled accessories etions. tch. t. accessories. TO S.A. MAIN 4 VOLUME DAMPER FLEXIBLE CONNECTION (MAX. 5 FT.) SUPPLY AIR DIFFUSER SQUARE OR RECTANGULAR DUCT THERMAL INSULATING BLANKET WHERE REQUIRED. -- rmostat. anty shall be provided by unit manufacturer. 1 ACCOUSTICAL UNING AIR FLOW CONICAL BELLMOUTH FITTING —VOLUME DAMPER, LOCATE ABOVE ACOUSTICAL CEILING OR OTHER ACCESSIBLE LOCATION. — SEAL WITH MASTIC AND DUCT TAPE — 1" WRAPPED ROUND RIGID DUCT TYPICAL ROUND DUCT TAKE -OFF DETAIL NTS - - INSULATED ROUND DUCT .tIII Jill" STRAP CLAMP (TYPICAL) FIRE DAMPER WHERE REQUIRED LAY — IN/PLASTER CEILING \ T— BAR/PLASTER FRAME DIFFUSER MOUNTING DETAIL NTS QUIPMENT SCHEDULE VOLTAGE/ IN TEGRAL TOTAL SENSIBLE O.A. PHASE HEATING COOLING COOLING CFM MBH (MBH) (MBH) 208V/30 38.4 35.3 34.7 220 UNIT WEIGHT (LB) 715 NOTES 9 )c; ' REVIEWED FOR CODE COMPLIANCE A PROVED MAY 12 2000 City Of Tukwila BUILD/14(: /IS /Q RECEIVED CITY OF TUKWILA MAY 0 6 2008 PERMIT CENTER 04/01/08 ISSUED TO CLIENT Nor Date Ration co* neotor must vasty d job dloudian., dkeRkTae, doioe, and weaNb.larne and Report any deareestiu b deigned s before procesdlrip will wodc Watt wS not be Idly for eny snug and OIUIBSias rat reported by Gemmel oa recto. DO NOT SCALE DRAWNG& BEN BRIDGE JEWELER SOUTH CENTER MALL 81 SOUTFICENTER MALL LEVEL 1, UNIT #740, TUKWILA, WA 98188 MECHANICAL DETAILS chealred Reid No. 740 9869 ID001 Senstuny s I 04/01/08 ISSUED TO LANDLORD We drain° not to be used for a9rn.buolon w mi*Tier.fQned. The midis of ens Thing ire be ooprlWltaWOand we not be room:ba d In whole or In pat wNhOnt be sprees wril.n consent albs aopyrlpht owner. W.1t w5 not mum meparulblllyttur.►4f surd more or cenhelas. 010 Watt IALJ DAVID A. UDKO ARCHITECT TENANT IMPROVEMENTS CONSULTING 11881 NORTH 113th WAY SCOTTSDALE. AZ. 85259 (480) 6143385 bus (480) 6140209 fax email: davidaudkow@cox.net Emphusls On Excellence IN-Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 PHONE 614.818.2323 FAX 614.818.2337 JOB estileid Working Drawing Review p Approved Approved as Noted [] Resubmit The drawings have been reviewed for general design Intent only. All actual field conditions are required to be verified by the Tenant's Architect and /or Contractor. Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings is required to be kept on the job site l times. 4/13/08 red Date Deb JANUARY 2007 806 AS NOTED Der ect ect DORM X1501 OF 7 SHEETS W T 410.304.9384 800 Beyrvlew Avenue F 410.304.1008 Toronto, ON w wetbn5.oate Conde A5A 3R7 vw.s .Ietluami b Rs Onvy Group Campo • • • DIVISION 15 - MECHANICAL SECTION 15000 MECHANICAL GENERAL PROVISIONS GENERAL CONDITIONS 1. DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND ALL OTHER SPECIFICATION SECTIONS ARE A PART OF THIS CONTRACT AND APPLY TO THIS AND THE OTHER SECTIONS OF DIVISION 15. 2. THE CONTRACTOR FOR THIS WORK IS REQUIRED TO READ THE ENTIRE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL OTHER TRADES. 3. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING HIS SUBCONTRACTORS WITH A FULL SET OF BID SET DOCUMENTS (INCLUDING SPECIFICATIONS) AND THE COORDINATION OF HIS WORK AND INSPECTIONS AND THE WORK AND INSPECTIONS OF HIS SUBCONTRACTORS WITH ALL OTHER TRADES ON SITE CONFORMING TO THE GENERAL CONTRACTOR'S TIME SCHEDULE. 4. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTING HIS BID TO DETERMINE CONDITIONS AFFECTING THE WORK. BIDS SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS AND ANY MODIFICATIONS WHICH ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS. FAILURE TO VISIT THE SITE DOES NOT RELIEVE THE CONTRACTOR OF RESPONSIBIUTY IN PERFORMANCE OF WORK. 5. WHEN USED, THE TERM "PROVIDED BY CONTRACTOR" SHALL BE INTERPRETED AS MEANING "FURNISHED AND INSTALLED" WITH THE EXCEPTION WHERE ITEMS ARE "FRONDED BY TENANT" WHICH MEANS "FURNISHED ONLY (INSTALLED BY CONTRACTOR), EXCEPT AS SPECIFICALLY NOTED OTHERWISE. GENERAL REQUIREMENTS 1. THE CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION, INCIDENTALS AND DETAILS NECESSARY TO PROVIDE A COMPLETE AND FULLY FUNCTIONAL MECHANICAL SYSTEM AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR. CLOSELY COORDINATE THE ENTIRE INSTALLATION WITH THE LANDLORD, AS REQUIRED. FIELD VERIFY THE EXACT TYPE, SIZE AND LOCATION, ETC. OF EXISTING PIPE AND DUCTS IN THE TENANT SPACE PRIOR TO BID. 2. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY MATERIAL OR LABOR CALLED FOR IN ONE SHALL BE PROVIDED EVEN THOUGH NOT SPECIFICALLY MENTIONED IN BOTH. ANY MATERIAL OR LABOR WHICH IS NEITHER SHOWN ON THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS, BUT WHICH IS OBVIOUSLY NECESSARY TO COMPLETE THE WORK, AND WHICH IS USUALLY INCLUDED IN WORK OF SIMILAR CHARACTER, SHALL BE PROVIDED AS PART OF CONTRACT. 3. WHERE THE DRAWINGS OR SPECIFICATIONS CALL FOR ITEMS WHICH EXCEED CODES OR THE LANDLORD'S TENANT CRITERIA, THE CONTRACTOR IS STILL RESPONSIBLE FOR PROVIDING THE SYSTEM AS DESIGNED AND DESCRIBED ON THESE DRAWINGS, UNLESS SPECIFICALLY NOTED OTHERWISE. 4. ALL MECHANICAL WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING, AND REPAIRING. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING SUFFICIENT ACCESS TO ALL EQUIPMENT FOR SERVICE. 5. THE CONTRACTOR SHALL DO ALL CUTTING, CORE DRILLING, CHASING OR CHANNELING AND PATCHING REQUIRED FOR ANY WORK UNDER THIS DIVISION. CUTTING SHALL HAVE PRIOR APPROVAL BY THE TENANT'S CONSTRUCTION MANAGER AND THE LANDLORD. PATCHING SHALL MATCH FINISH OF SURROUNDING AREA. CODES 1. ALL WORK SHALL BE PERFORMED IN A NEAT PROFESSIONAL MANNER USING GOOD ENGINEERING PRACTICES. ALL WORK SHALL CONFORM TO THE LANDLORD'S CRITERIA, THE STATE'S, COUNTY'S, CITY'S AND LOCAL CODES AND ORDINANCES, SAFETY AND HEALTH CODES, NFPA CODES, ENERGY CODES AND ALL OTHER APPLICABLE CODES AND REQUIREMENTS. THE CONTRACTOR SHALL INQUIRE INTO AND COMPLY WITH ALL APPLICABLE CODES, ORDINANCES, AND REGULATIONS. AFTER CONTRACT IS ISSUED, NO ADDITIONAL COST DUE TO CODE ISSUES SHALL BE REIMBURSED BY THE TENANT TO THE CONTRACTOR. LICENSES, PERMITS, INSPECTIONS & FEES 1. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LICENSES, PERMITS, INSPECTIONS, AND FEES REQUIRED OR RELATED TO HIS WORK. 2. FURNISH TO THE TENANT'S CONSTRUCTION MANAGER ALL CERTIFICATES OF INSPECTION AND FINAL INSPECTION APPROVAL AT SUBSTANTIAL COMPLETION DATE OF PROJECT. DRAWINGS 1. DRAWINGS (PLANS, SPECIFICATIONS, AND DETAILS) ARE DIAGRAMMATIC AND INDICATE THE GENERAL LOCATION AND INTENT OF THE MECHANICAL SYSTEMS. BECAUSE OF THE SMALL SCALE OF THE DRAWINGS, IT IS NOT POSSIBLE TO INDICATE ALL DUCT AND PIPING OFFSETS, FITTINGS AND ACCESSORIES THAT MAY BE REQUIRED. 2. THE LAYOUT SHOWN ON THE DRAWINGS IS BASED ON A PARTICULAR MAKE OF EQUIPMENT. IF ANOTHER MAKE OF EQUIPMENT IS USED WHICH REQUIRES MODIFICATION OR CHANGE OF ANY DESCRIPTION FROM THE DRAWINGS OR SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE AS PART OF THIS WORK, FOR MAKING ALL SIGH MODIFICATIONS AND CHANGES, INCLUDING THOSE INVOLVING OTHER TRADES WITH THE COST THEREOF INCLUDED IN HIS BID. IN SUCH CASE, CONTRACTOR SHALL SUBMIT DRAWINGS AND SPECIFICATIONS PRIOR TO STARTING WORK SHOWING ALL SUCH MODIFICATIONS AND CHANGES. HIS PROPOSAL SHALL BE SUBJECT TO THE APPROVAL OF THE TENANT'S CONSTRUCTION MANAGER. EXISTING SHELL SPACE CONDIIONS I. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF THE DEMOLITION OF EXISTING MECHANCIAL WORK SHOWN ON THE MECHANCIAL DRAWINGS AND THE MECHANCIAL DEMOLITION SHOWN ON THE ARCHITECTURAL DRAWINGS. 2. THE CONTRACTOR SHALL INCLUDE, AND WILL BE HELD RESPONSIBLE FOR, THE REMOVAL OF ALL EXISTING FIRE PROTECTION, PLUMBING FIXTURES, PIPING, HVAC UNITS, REFRIGERANT RECAPTURE, EXHAUST FANS, ETC. AND ASSOCIATED ROOF CURBS NOT TO BE REUSED ON THIS PROJECT, UNLESS SPECIFICALLY NOTED OTHERWISE. CONTRACTOR MUST VERIFY WITH THE LANDLORD ALL PRESUMED ABANDONED EQUIPMENT, PIPES, DUCTWORK, AND EQUIPMENT PRIOR TO REMOVAL. ROOF CURBS SHALL BE REMOVED AND THE ROOF PATCHED UNLESS NOTED FOR REUSE OR RECONFIGURATION ON PLANS, ROOF PATCHING SHALL BE PERFORMED AT THE CONTRACTOR'S EXPENSE BY A ROOFING CONTRACTOR APPROVED BY THE LANDLORD. ALL EXTRANEOUS ITEMS IN THE SPACE OR ON THE ROOF (ABOVE THIS SPACE) NOT APPLICABLE TO THE NEW WORK OR PART OF THE LANDLORD'S OR ANOTHER TENANT'S ACTIVE SYSTEM MUST BE REMOVED AND ROOF /WALL /FLOOR PATCHED /REPAIRED TO MATCH EXISTING STRUCTURE. EXISTING ABANDONED PIPES, DUCTS, OR EQUIPMENT IN THE FLOOR, EMBEDDED IN CONCRETE, OR OTHERWISE INACCESSIBLE ARE TO BE CUT OFF AND SEALED BELOW OR WITHIN FLOOR OR WALL LEVEL WHEN THEY ARE NOT TO BE REUSED IN THIS PROJECT. IF REQUIRED BY LANDLORD OR CODES, ABANDONED PIPING AND /OR DUCTWORK MUST BE REMOVED TO POINT OF ORIGIN. CONFIRM THE EXTENT OF DEMOLITION PRIOR TO BID AND INCLUDE IN BID PROPOSAL. 3. ACTIVE LANDLORD OR OTHER TENANT SERVICES ENCOUNTERED IN WORK SHALL BE PROTECTED AND SUPPORTED. IF EXISTING SERVICES NOT ANTICIPATED REQUIRE RELOCATION, CONTACT THE TENANT'S CONSTRUCTION MANAGER IMMEDIATELY. ALL COSTS FOR REPAIR OF DAMAGES TO ACTIVE LANDLORD OR OTHER TENANT SERVICES DURING CONSTRUCTION SHALL BE PAID FOR BY THE CONTRACTOR CAUSING THE DAMAGE. 4. TIE -INS AND MODIFICATIONS TO EXISTING LANDLORD SERVICES MUST BE DONE WITH MINIMUM INTERRUPTION OF LANDLORD OPERATION AND DURING HOURS SPECIFIED BY THE LANDLORD. THE CONTRACTOR IS RESPONSIBLE FOR CONFIRMING EXACT WORKING HOURS OF THIS WORK WITH THE LANDLORD PRIOR TO SUBMITTING HIS BID. THE CONTRACTOR SHALL INCLUDE IN HIS BID, ALL PREMIUM TIME REQUIRED TO PERFORM MODIFICATIONS DURING OTHER THAN NORMAL WORKING HOURS. ALL SUCH WORK MUST BE COORDINATED WITH THE LANDLORD. DISCREPANCIES IN DOCUMENTS 1. DRAWINGS (PLANS, SPECIFICATIONS, AND DETAILS) ARE DIAGRAMMATIC AND INDICATE THE GENERAL LOCATION AND INTENT OF THE MECHANICAL SYSTEMS. WHERE DRAWINGS, EXISTING SITE CONDITIONS, SPECIFICATIONS OR OTHER TRADES CONFLICT OR ARE UNCLEAR, ADVISE THE GENERAL CONTRACTOR IN WRITING, PRIOR TO SUBMITTAL OF BID. THE GENERAL CONTRACTOR IS RESPONSIBLE TO ADVISE THE TENANT'S CONSTRUCTION MANAGER, IN WRITING, OF VARIATIONS TO CONTRACT DOCUMENTS PRIOR TO SUBMISSION OF BID. OTHERWISE, TENANT'S CONSTRUCTION MANAGER'S INTERPRETATION OF CONTRACT DOCUMENTS OR CONDITIONS SHALL BE FINAL WITH NO ADDITIONAL COMPENSATION PERMITTED. TRADE NAMES AND MANUFACTURERS 1. WHERE TRADE NAMES AND MANUFACTURERS ARE USED ON THE DRAWINGS OR IN THE SPECIFICATIONS, THE EXACT EQUIPMENT SHALL BE USED AS A MINIMUM STANDARD FOR THE BASE BID. MANUFACTURERS CONSIDERED AS AN EQUAL OR BETTER IN ALL ASPECTS TO THAT SPECIFIED WILL BE SUBJECT TO APPROVAL IN WRITING BY THE TENANT'S CONSTRUCTION MANAGER PRIOR TO ACCEPTANCE. THE USE OF ANY UNAUTHORIZED EQUIPMENT SHALL BE SUBJECT TO REMOVAL AND REPLACEMENT AT THE CONTRACTOR'S EXPENSE. L SHOP DRAWINGS 1. SUBMIT SIX COPIES OF MATERIAL LISTS AND SHOP DRAWINGS FOR ALL EQUIPMENT AND DUCT FABRICATION DRAWINGS TO THE TENANT'S CONSTRUCTION MANAGER FOR APPROVAL PRIOR TO ORDERING EQUIPMENT. SUBMISSIONS MUST BE EARLY ENOUGH TO ALLOW THE TENANT'S CONSTRUCTION MANAGER EIGHT WORKING DAYS FOR REVIEW WITHOUT CAUSING DELAYS OR CONFLICTS TO THE JOB'S PROGRESS. SUBMITTALS SHALL BE IN ACCORDANCE WITH THE GENERAL CONDITIONS USING THE MANUFACTURER'S LISTED ON THE DRAWINGS. SHOP DRAWINGS SHALL INCLUDE ALL DATA THAT PERTAINS TO THE REQUIREMENTS SET FORTH ON THE DRAWINGS AND IN THE SPECIFICATIONS. THE SUBMITTAL SHALL INCLUDE BUT NOT LIMITED TO CUTS OR CATALOGS INCLUDING DESCRIPTIVE LITERATURE AND CHARACTERISTICS OF EQUIPMENT SHALL SHOW MAJOR DIMENSIONS, ROUGHING -IN DATA, CAPACITY, CURVES, PRESSURE DROP, CODE COMPLIANCE, MOTOR AND DRIVE DATA AND ELECTRICAL DATA. OBSERVE SPECIAL INSTRUCTIONS WHEN REQUIRED. SUBIJ FFALS SHALL BEAR THE STAMP OF THE GENERAL AND SUB - CONTRACTOR SHOWING THAT HE HAS REVIEWED AND CONFIRMED THAT THEY ARE IN CONFORMANCE WITH THE CONTRACT DRAWINGS AND SPECIFICATIONS OR INDICATE WHERE EXCEPTIONS TAKE PLACE. LACK OF SUCH CONTRACTOR'S RENEW AND APPROVAL WILL BE CAUSE FOR REJECTION WITHOUT REVIEW BY TENANT'S CONSTRUCTION MANAGER. ALL SHOP DRAWINGS MUST APPEAR IN THE OPERATION AND MAINTENANCE MANUALS LEFT ON SITE AT JOB COMPLETION. I 2. INSTALL ALL NECESSARY PIPE HANGERS, SADDLES, AND CARRIERS TO PROPERLY SUPPORT ALL PIPING AND FIXTURES. HANGERS SHALL SUIT TYPE OF PIPING PROVIDED AND BE SPACED AT A MAXIMUM SPAN OF 5 FEET. PROVIDE SWAY AND SEISMIC BRACING WHERE REQUIRED BY CODES. 3. ESCUTCHEONS SHALL BE CHROME PLATED, SIZE AS REQUIRED AND PLACED AT ALL PIPE PENETRATIONS AT WALLS, FLOORS, AND CEILINGS IN FINISHED AREAS. 4. FLASHING SHALL BE SEALED WATERTIGHT AND PERFORMED IN ACCORDANCE TO THE LANDLORD'S CRITERIA. USE A LANDLORD APPROVED ROOFING CONTRACTOR WHERE APPLICABLE. J. RECORD DRAWINGS 1. THE CONTRACTOR SHALL MAINTAIN ONE COPY OF DRAWINGS AND SPECIFICATIONS ON THE JOB SITE TO RECORD DEVIATIONS FROM CONTRACT DRAWINGS, SUCH AS: 2. AT COMPLETION OF THE PROJECT AND BEFORE FINAL APPROVAL, THE CONTRACTOR SHALL MAKE ANY FINAL CORRECTIONS TO DRAWINGS AND CERTIFY THE ACCURACY OF EACH PRINT BY SIGNATURE THEREON. THE DRAWINGS ARE TO BE TURNED OVER TO THE TENANT. K. GUARANTEE 1. THE CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORK UNDER HIS CONTRACT AND SHALL MAKE GOOD, REPAIR OR REPLACE AT HIS OWN EXPENSE, ANY DEFECTIVE WORK, MATERIAL, OR EQUIPMENT WHICH MAY BE DISCOVERED WITHIN A PERIOD OF 12 MONTHS FROM THE DATE OF ACCEPTANCE (IN WRITING) OF THE INSTALLATION BY THE TENANT'S CONSTRUCTION MANAGER. PROVIDE EXTENDED WARRANTIES AS SPECIFIED WITH INDIVIDUAL EQUIPMENT. IN CASE OF REPLACEMENT OR REPAIR OR EQUIPMENT DUE TO FAILURE WITHIN GUARANTEE PEROID, GUARANTEE ON THAT PORTION OF WORK SHALL BE EXTENDED FOR A PEROID OF ONE (1) YEAR FROM DATE OF SUCH REPLACEMETN OR REPAIR. L OPERATIONS MANUALS 1. ONE COPY OF EACH OPERATION AND MAINTENANCE MANUAL FOR ALL EQUIPMENT FURNISHED ON JOB SHALL BE COLLECTED AND INSERTS') IN A 3" THREE RING BINDER AND TURNED OVER TO THE TENANT. EACH NO SHALL INCLUDE BUT NOT BE LIMITED TO INSTALLATION, MAINTENANCE AND CPERATING INSTRUCTIONS, PAMPHLETS OR BROCHURES APPROVED SHOP DRAWINGS AND WARRANTIES OBTAINED FROM EACH MANUFACTURER OF PRINCIPAL ITEMS OF EQUIPMENT. M. SLEEVES 1. THE CONTRACTOR SHALL PROVIDE SLEEVES TO PROTECT EQUIPMENT OR FACILITIES IN THE INSTALLATION. EACH SLEEVE SHALL EXTEND THROUGH IT'S RESPECTIVE FLOOR, WALL OR PARTITION AND SHALL BE CUT FLUSH WITH EACH SURFACE EXCEPT SLEEVES THAT PENETRATE THE FLOOR, WHICH SHALL EXTEND 2" ABOVE THE FLOOR. 2. ALL SLEEVES AND OPENINGS THROUGH FIRE RATED WAU..S AND /OR FLOORS SHALL BE FIRE SEALED WITH CALCIUM SILICATE, SILICONE "RTV' FOAM, "3M" FIRE RATED SEALANTS OR EQUAL, SO AS TO RETAIN THE FIRE RATING OF THE FLOOR OR WALL. CONFORM TO U.L. ASSEMBLY RATING OF FLOOR OR WALL. 3. SLEEVES IN BEARING AND MASONRY WALLS, FLOORS, AND PARTITIONS SHALL BE STANDARD WEIGHT STEEL PIPE FINISHED WITH SMOOTH EDGES. FOR OTHER THAN MASONRY PARTITIONS, THROUGH SUSPENDED CEIUNGS, OR FOR CONCEALED VERTICAL PIPING, SLEEVES SHALL BE NO. 22 U.S.G. GALVANIZED STEEL MINIMUM. 4. DUCT SLEEVES TO BE MINIMUM 14 GAUGE STEEL. N. HANGERS 1. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS ANGLE IRON, BANDS, C- CLAMPS WITH RETAINING CLIPS, CHANNELS, HANGER RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK. 2. HANGERS SHALL BE FASTENED TO BUILDING STEEL, CONCRETE, OR MASONRY, BUT NOT TO PIPING OR DUCTWORK. HANGING FROM METAL DECK IS NOT PERMITTED. HANGERS MUST BE ATTACHED TO UPPER CHORD OF BAR JOIST. WHERE INTERFERENCES OCCUR, IN ORDER TO SUPPORT DUCTWORK OR PIPING, THE CONTRACTOR MUST INSTALL TRAPEZE TYPE HANGERS OR SUPPORTS WHICH SHALL BE LOCATED WHERE THEY DO NOT INTERFERE WITH ACCESS TO FIRE DAMPERS, VALVES, ACCESS DOORS AND OTHER EQUIPMENT SERVICE REQUIREMENTS AND /OR OTHER TRADES. HANGER TYPES AND INSTALLATION METHODS ARE SUBJECT TO LANDLORD CRITERIA. 3. HANGERS FOR ALL INSULATED PIPING SHALL BE SIZED AND INSTALLED FOR THE OUTER DIAMETER OF INSULATION. INSTALL 5" LONG SPLT CIRCLE GALVANIZED SADDLE BETWEEN THE HANGER AND THE PIPE INSULATION. 4. HANGERS AND PIPING OF DISSIMILAR METALS SHALL BE DI- ELECTRICALLY SEPARATED FROM ONE ANOTHER. O. ACCESS DOORS A. LOCATION OF CONCEALED PIPING VALVES AND DUCTS. B. REVISIONS, ADDENDUMS, AND CHANGE ORDERS. C. SIGNIFICANT DEVIATIONS MADE NECESSARY BY FIELD CONDITIONS, APPROVED EQUIPMENT SUBSTITUTIONS, AND CONTRACTOR'S COORDINATION WITH OTHER TRADES. D. EXACT ROUTING OF ALL SANITARY AND DOMESTIC WATER PIPING UNDER FLOOR. 1. FURNISH STEEL ACCESS DOORS AND FRAMES, MIN. 16 "X 20" OR AS SHOWN ON DRAWINGS, TO GENERAL CONTRACTOR FOR ALL LOCATIONS WHERE NECESSARY TO PROVIDE ACCESS TO CONCEALED VALVES, AND OTHER EQUIPMENT REQUIRING SERVICE OR INSPECTION. LOCATION, TYPE, SIZE AND NUMBER AS DETERMINED BY CONTRACTOR AND APPROVED BY TENANT CONSTRUCTION MANAGER TO SUIT EQUIPMENT REQUIREMENTS. GENERAL CONTRACTOR WILL INSTALL ACCESS DOORS AND FRAMES. 2. ACCESS DOORS LOCATED IN FIRE -RATED WALLS, FLOORS, CEILING -FLOOR OR CEILING -ROOF ASSEMBLIES SHALL BE FIRE RATED, UNDERWRITER'S LABORATORIES, INC., USTED AND LABELED. 3. ACCESS DOORS SHALL BE FLUSH TYPE, MANUFACTURED FROM NO. 14 GAUGE STEEL, COMPLETE WITH FLUSH FLANGE TYPE FRAMES MANUFACTURED FROM NO. 16 GAUGE STEEL, PROVIDED WITH ANCHORS. ACCESS DOORS SHALL BE SUITABLE FOR INSTALLATION IN WALL OR CEILING MATERIALS SHOWN IN ROOM FINISH SCHEDULES. P. ELECTRICAL MOTORS 1. FURNISH, INSTALL AND ALIGN ALL MOTORS REQUIRED KR THIS EQUIPMENT. UNLESS THEY ARE FACTORY INSTALLED ON THE UNIT, ALL STARTERS AND ASSOCIATED WIRING AND SAFETY SWITCHES FOR SUCH MOTORS SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. STARTERS SHALL MEET ALL REQUIREMENTS AS DEFINED IN THE ELECTRICAL DIVISION OF THE SPECIFICATIONS. 2. DESIGN, CONSTRUCTION AND PERFORMANCE CHARACTERISTICS OF MOTORS SHALL CONFORM TO ALL APPLICABLE PROVISIONS OF LATEST NEMA, ANSI, ISEE STANDARDS FOR ELECTRICAL EQUIPMENT. ALL MOTORS SHALL BE SUITABLE FOR OPERATION ON VOLTAGE VARIATION OF PLUS OR MINUS 10 %, 40 DEGREES C AMBIENT TEMPERATURE; HAVE A SERVICE FACTOR OF NOT LESS THAN 1.15. Q. LOW VOLTAGE (24 VOLT) WIRING 1. THE CONTRACTOR IS TO INSTALL ALL LOW VOLTAGE WIRING REQUIRED FOR HIS EQUIPMENT. THIS WORK INCLUDES ALL TRANSFORMERS AND DEVICES TO MAKE THIS A COMPLETE FUNCTIONAL SYSTEM. 2. ALL WORK IS TO CONFORM TO THE LATEST ADDITION N,E.0 AND TO DIVISION 16 ELECTRICAL SPECIFICATIONS. 3. ANY CONDUIT REQUIRED BY CODE OR THE LANDLORD WILL BE INSTALLED BY THE ELECTRICAL SUBCONTRACTOR. A. SCOPE OF WORK DIVISION 15 - MECHANICAL SECTION 15200 PLUMBING 1. THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE PLUMBING SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN T HE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: (REFER TO RESPONSIBILITY SCHEDULE FOR EXACT RESPONSIBILITIES) A. COMPLETE SANITARY PIPING SYSTEMS OF WASTE, DRAINS, AND VENTS. B. COMPLETE COLD AND HOT WATER PIPING SYSTEMS, APPURTENANCES AND INSULATION. C. PLUMBING FIXTURES AND EQUIPMENT AS SCHEDULED. D. COMPLETE NATURAL GAS PIPING SYSTEMS (AS APPLICABLE, REFER TO PLANS). E. TESTS AND ADJUSTMENTS. 2. BEFORE STARTING WORK, THIS CONTRACTOR SHALL EXAMINE THE ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL PLANS AND SPECIFICATIONS TO SEQUENCE, COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE PLUMBING SYSTEM, MATERIALS, AND EQUIPMENT WITH OTHER CONTRACTORS TO AVOID INTERFERENCES AND CONFRONTATIONS. 3. RELOCATION OF EXISTING WATER, GAS, WASTE, VENT, OR DRAINAGE LINES TO FACIUTATE STORE DESIGN CRITERIA MUST BE INCLUDED IN BID PROPOSAL. B. PLUMBING EQUIPMENT C. GENERAL PIPING REQUIREMENTS 1. GENERALLY, SANITARY AND POTABLE WATER TAPS WILL BE PROVIDED BY THE LANDLORD. FIELD VERIFY EXACT CONNECTION POINTS PRIOR TO SUBMITTING BID AND NOTIFY THE TENANT'S CONSTRUCTION MANAGER IF CONDITIONS ARE NOT AS SHOWN ON THE PLANS OR AS STATED IN THE SPECIFICATIONS. CONTRACTOR MUST VERIFY THE OPERABILITY OF ENTIRE SYSTEM PRIOR TO TIE IN AS FOLLOWS: A. SNAKE SANITARY FOR A DISTANCE OF 100 FEET AND REPORT ANY BLOCKAGE. B. TEST WATER PRESSURE TO INSURE MINIMUM OF 50 PSI. D. PIPING 1. SANITARY PIPING - NO PVC ALLOWED (STORM PIPING AS REQUIRED) A. WASTE, DRAIN AND VENT PIPING SHALL BE SERVICE WEIGHT, CAST IRON SOIL PIPE. VENT PIPING ABOVE FLOOR 2" OR SMALLER MAY BE GALVANIZED STEEL. B. JOINTS: BELOW FLOOR SLAB - COMPRESSION TYPE PLASTIC SEAL (HUB AND SPIGOT). ABOVE FLOOR SLAB - NEOPRENE SEALING SLEEVE WITH STAINLESS STEEL SHIELD AND CLAMP WITH APPROVED NEOPRENE - BASED LUBRICANT, (HUBLESS). GALVANIZED VENT -- SCREWED JOINTS WITH TEFLOW TAPE ON MALE THREADS. C. PITCH WASTE LINES 2" AND SMALLER NOT LESS THAN 1/4" PER FOOT. PITCH LARGER MAINS NOT LESS THAN 1/8" PER FOOT. D. INSTALL A CLEANOUT AT BASE OF EACH SOIL STACK, AT EACH CHANGE IN DIRECTION, AT INTERVALS NOT OVER 50 FEET, AND ELSEWHERE AS SHOWN ON DRAWINGS OR REQUIRED BY LOCAL CODE. CLEANOUTS SHALL NOT BE INSTALLED IN PUBLIC AREAS WITHOUT SPECIFIC PERMISSION BY TENANT'S CONSTRUCTION MANAGER; BUT WHERE NECESSARY, THE WALL COVERS ARE TO BE STAINLESS STEEL AND THE FLOOR COVERS ARE TO BE BRASS (FLUSH WITH FINISHED FLOOR). PROVIDE COVERS WITH INSET AREA FOR CARPETED FLOOR LOCATIONS. ALL CLEAN -OUT LOCATIONS SHALL BE APPROVED BY THE TENANT'S CONSTRUCTION MANAGER. E. INSULATE ALL HORIZONAL RUNS OF PIPING LOCATED IN CEILING SPACES WHEN APPLICABLE. INSULATION TO BE AS SPECIFIED FOR WATER PIPING. F. INSULATE THE TRAP, SANITARY AND SUPPLY PIPES UNDER LAVATORY WITH 1/2" ARMSTRONG "ARMAFLEX" PIPING INSULATION OR TRUEBRO MODEL 102W "HANDI LAV GUARD" INSULATION KIT. 2. CONDENSATE PIPING SHALL BE TYPE "L" DRAWN COPPER TUBE WITH 95 -5 TIN - ANTIMONY SOLDERED JOINTS AND WROUGHT COPPER FITTINGS WITH DIELECTRIC SEPARATION BETWEEN DISSIMILAR METALS. 3. POTABLE WATER PIPING: A. BELOW GRADE: TYPE 'K', ANNEALED TEMPERED COPPER TUBE FOR PIPE SIZES 2 INCHES AND SMALLER. BRAZE ALL JOINTS. B. ABOVE GRADE: TYPE 'L' DRAWN COPPER TUBE WITH WROUGHT COPPER FITTINGS AND 95 -5 TIN - ANTIMONY SOLDER. C. INSTALL AIR CHAMBER SHOCK ABSORBERS IN PIPING SYSTEM TO PREVENT NOISE AND DAMAGE DUE TO WATER HAMMER. D. ALL BRANCH PIPING SYSTEM SHALL HAVE ACCESSIBLE SERVICE VALVE. PROVIDE SHUT OFF VALVES IN THE SUPPLY PIPING TO EVERY FIXTURE. PROVIDE ACCESS DOORS WHERE NECESSARY. E. PROVIDE WATER METER AND REMOTE READER PER LANDLORD'S CRITERIA OR LOCAL UTILITIES REQUIREMENTS IF APPLICABLE. REFER TO PLANS TO DETERMINED IF WATER METER IS REQUIRED. F. SECURE PIPE AT ANGLE STOPS. G. PROVIDE FLEXIBLE INSERTS AT ALL PIPE PENETRATIONS THROUGH FRAMING TO KEEP PIPES FROM HITTING FRAME WHEN IN OPERATION. DIVISION 15 - MECHANICAL SECTION 15300 FIRE PROTECTION THE SPRINKLER CONTRACTOR IN CONJUNCTION WITH HIS ENGINEER AND THE GENERAL CONTRACTOR SHALL SURVEY THE SITE PRIOR TO DESIGNING THE SPRINKLER SYSTEM. THE SPRINKLER CONTRACTOR SHALL ENSURE THAT THE SYSTEM DESIGN COMPLIES TO THE FOLLOWING REQUIREMENTS: THE SPRINKLER SYSTEM DESIGN AND INSTALLATION SHALL CONFORM TO CODE. THE SPRINKLER SYSTEM SHALL BE DESIGNED AND INSTALLED IN A MANNER TO PRECLUDE ANY DAMAGE CAUSED BY A FAILURE OF THE SPRINKLER SYSTEM DUE TO ENVIRONMENTAL CONDITIONS. ENVIRONMENTAL CONDITIONS ARE TO INCLUDE, BUT NOT BE LIMITED TO TEMPERATURE (FREEZING AND EXCESSIVE HEAT), BUILDING SHELL EXPANSION /CONTRACTION CYCLES, AIR LEAKAGE, STACK EFFECTS, ETC. OCCURRING IN ANY PLENUM OR CAVITY WHERE THE SPRINKLER SYSTEM IS ROUTED. THE SPRINKLER CONTRACTOR SHALL COORDINATE THE SPRINKLER SYSTEM DESIGN AND INSTALLATION WITH THE BUILDING LANDLORD AND GENERAL CONTRACTOR TO INSURE SYSTEM FUNCTION. A. SCOPE OF WORK 1. THE F.P. CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE SPRINKLER SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: (REFER TO RESPONSIBILITY SCHEDULE FOR EXACT RESPONSIBILITIES) A. INSTALLATION OF NEW WET SPRINKLER SYSTEM AS REQUIRED TO PROVIDE COVERAGE IN ACCORDANCE WITH NFPA -13, LOCAL CODES, LANDLORD'S CRITERIA, AND INSURANCE CARRIERS FOR THE MALL AND TENANT. B. TAPS, RISERS, LATERALS, BRANCHES, VALVES, ALARMS, SPRINKLER HEADS AND ALL COMPONENTS REQUIRED FOR A COMPLETE SYSTEM. C. DESIGN DRAWINGS, CALCULATIONS, SUBMITTALS AND APPROVALS. D. PERMITS, FEES, AND CHARGES. E. TESTS AND TEST CERTIFICA T:ES. F. COST FOR SHUT DOWN FEES. 2. THE CONTRACTOR THAT DOES THE ACTUAL SPRINKLER WORK IS REQUIRED TO BE A LANDLORD APPROVED SPRINKLER CONTRACTOR. 3. BEFORE STARTING WORK, THE CONTRACTOR SHALL EXAMINE THE ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL PLANS AND SPECIFICATIONS TO SEQUENCE, COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE FIRE PROTECTION SYSTEM, MATERIALS, AND EQUIPMENT WITH OTHER CONTRACTORS TO AVOID INTERFERENCES AND CONFRONTATIONS. 4. RELOCATION OF EXISTING MAINS, LATERALS, BRANCHES AND RISERS TO FACILITATE STORE DESIGN CRITERIA MUST BE INCLUDED IN BID PROPOSAL B. SHOP DRAWINGS 1. THE FIRE PROTECTION CONTRACTOR SHALL PREPARE DETAILED SHOP DRAWINGS AND CALCULATIONS FOR HIS WORK. SUBMIT SIX (6) COPIES TO GENERAL CONTRACTOR FOR APPROVAL. NO WORK SHALL BEGIN UNTIL TENANT'S CONSTRUCTION MANAGER APPROVES HEAD AND PIPING LOCATIONS. 2. THE FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR SUBMITTING COORDINATED DRAWINGS, CALCULATIONS, HEAD TYPES AND COLORS TO ALL AUTHORITIES HAVING JURISDICTION FOR APPROVAL. NO WORK SHALL BEGIN UNTIL ALL APPROVALS HAVE BEEN RECEIVED. 3. A COPY OF THE LETTER OF APPROVAL FROM THE LANDLORD'S INSURANCE RATING BUREAU SHALL BE FORWARDED TO THE LANDLORD'S AGENT AND TO THE TENANT'S CONSTRUCTION MANAGER. C. EQUIPMENT 1. SPRINKLER HEADS: A. ALL SPRINKLER HEADS SHALL BE NEW (EXISTING HEADS IN EXISTING STORES TO BE REPLACED), U.L., F.M. LISTED AND APPROVED AUTOMATIC SPRAY TYPE AS MANUFACTURED BY CENTRAL SPRINKLER CO., GLOBE, GRINNELL, RELIABLE, STAR, OR VIKING. B. ALL SPRINKLER HEADS SHALL BE RATED FOR 1650F UNLESS INDICATED OTHERWISE ON DRAWINGS OR REQUIRED BY LOCAL CODES. C. ALL SALES FLOORS HEADS ARE TO HAVE BE FACTORY APPLIED COLOR FINISH TO MATCH ARCHITECTURAL CEILING FINISH. VERIFY HEAD TYPES AND COLORS WITH TENANT'S CONSTRUCTION MANAGER AND SUBMIT WITH SPRINKLER DRAWINGS FOR PERMIT. D. SPRINKLER HEAD TYPES SHALL BE AS FOLLOWS: 1. FINISHED CEILING - CHROME PENDANT TYPE. 2. NO- CEILING - CHROME UPRIGHT TYPE. NOTE:SEMI - RECESSED HEADS SHALL PROTRUDE NO MORE THAN 1" BELOW LEVEL OF CEILING OF SOFFIT. ALL HORIZONTAL SPRINKLER RUNS AT SIDEWALL SOFFITS SHALL BE CONSEALED WITHIN SOFFIT FRAMING. D. GENERAL PIPING 1 A FIRE PROTECTION SYSTEM STUB IN SHALL BE FURNISHED BY THE LANDLORD. SPRINKLER SPACING SHALL NOT EXCEED 130 SQ. FT. IN "SALES" AREAS AND 100 SQ. FT. IN "STOCK" AREAS. COMPLY WITH LANDLORD'S DESIGN CRITERIA. PIPE SIZING SHALL BE BASED ON NFPA ORDINARY HAZARD. 2. ALL SPRINKLER LINES SHALL INSTALLED CONCEALED, AVOIDING L S LJ LL BE S LLED CO CEALED, 0 DING INTERFERENCE WITH LIGHTS, DUCTS, PIPES, STORAGE DECK, ETC. FIRE PROTECTION CONTRACTOR SHALL PREPARE COORDINATED SHOP DRAWINGS INDICATING THE LOCATIONS OF ALL SPRINKLER HEADS, SPRINKLER LINES, LIGHTS, DIFFUSERS, GRILLES AND REGISTERS PRIOR TO INSTALLATION. HORIZONTAL SPRINKLER RUNS AT MERCHANDISE SOFFITS SHALL BE PLACED INSIDE SOFFIT STRUCTURE. VERTICAL DROPS FROM CEILING TO MERCHANDISE SOFFIT SHALL BE LOCATED FLUSH AGAINST DEMISING WALLS. 3. WHERE POSSIBLE, REWORK THE EXISTING SPRINKLER SYSTEM TO MEET THE NEW REQUIREMENTS OF THIS DESIGN. RELOCATE ALL MAINS AND BRANCHES INTERFERING WITH CEILING HEIGHTS, EQUIPMENT, AND MAJOR COMPONENTS INCLUSIVE OF ADJACENT TENANTS AND MALL COMMON AREAS. REMOVE ALL UNUSED PIPING. 4. LOCATIONS OF ALL HEADS SHOULD BE APPROVED BY THE LOCAL FIRE PROTECTION OFFICIAL AND THE TENANT'S CONSTRUCTION MANAGER BEFORE INSTALLATION. HEADS MUST BE LOCATED IN THE CENTER OF CEILING TILES AND IN A SYMMETRICAL PATTERN WITH OTHER CEIUNG FIXTURES. ADDITIONAL MONIES WILL NOT BE ALLOCATED FOR ADDITIONAL HEADS REQUIRED BY FIELD FIRE INSPECTOR AFTER BIDS ARE ACCEPTED. HEADS IN MERCHANDISE BAYS SHALL BE CENTERED SIDE TO SIDE AND FRONT TO BACK. 5 PROVIDE AND INSTALL A VALVED TEST CONNECTION FOR THE SPRINKLER SYSTEM AS REQUIRED OR REQUESTED BY THE MALL, LOCAL INSPECTOR, OR INSURANCE CARRIER. COORDINATE LOCATION WITH TENANT'S CONSTRUCTION MANAGER AND LOCAL FIRE PROTECTION OFFICIAL PRIOR TO ROUGH -IN. 6. SPRINKLER HEADS LOCATED IN STOCK, CORRIDOR ON TOILET ROOM CEILINGS OR WALLS BELOW B' -0" ABOVE THE FINISHED FLOOR ARE TO BE PROTECTED WITH APPROVED GUARDS. E. PIPING: F. TESTS A. B. C. D. E. F. G. H. I. J. K. B. HVAC EQUIPMENT DIVISION 15 - MECHANICAL SECTION 15500 HEATING, VENTILATION, AND AIR CONDITIONING A. SCOPE OF WORK 3. CURBS AND STEEL FRAMING FOR SUPPORT E. METAL DUCTWORK - NO FIBERGLASS DUCT ALLOWED 5. INSTALL DOUBLE THICKNESS TURNING VANES IN ALL RIGHT ANGLE ELBOWS. 12. FLEXIBLE CONNECTIONS 1. SCHEDULE 40, BLACK STEEL PIPE, ASTM A -53 FOR FERROUS PIPING, WELDED AND SEAMLESS, ANSI B- 36 -10 -70 FOR WROUGHT STEEL PIPE. 2. CAST IRON OR MALLEABLE IRON SCREWED FITTINGS FOR PIPES 2 INCHES AND SMALLER. SCREWED OR CAST IRON FLANGED JOINTS FOR PIPES LARGER THAN 2 INCHES. 3. GALVANIZED OR BLACK MALLEABLE IRON WITH BRASS SEAT SCREWED UNIONS FOR PIPES 2 INCHES AND SMALLER. 4. VICTAULIC TYPE COUPLINGS ARE ACCEPTABLE, WHERE APPROVED BY CODE AND THE LANDLORD. 1. WHEN COMPLETED, THE ENTIRE FIRE PROTECTION PIPING SYSTEM SHALL BE HYDROSTATICALLY TESTED AS REQUIRED BY THE RULES AND REGULATIONS OF THE AUTHORITIES HAVING JURISDICTION. SYSTEM SHALL SHOW NO SIGNS OF LEAKAGE OR OTHER DEFECTS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO THE WORK OF THE OTHER CONTRACTORS OR TO THE BUILDING, OR TO ITS CONTENTS, PEOPLE, ETC., CAUSED BY LEAKS IN ANY OF THE EQUIPMENT INSTALLED BY HIM. ALL REPAIRS OR REPLACEMENT OF DAMAGES SHALL BE AT THIS CONTRACTOR'S EXPENSE. 2. PROPERLY COMPLETED AND SIGNED "SPRINKLER CONTRACTOR'S MATERIAL AND TEST CERTIFICATES" SHALL BE FURNISHED TO THE LANDLORD, AUTHORITIES HAVING JURISDICTION, AND TENANT'S CONSTRUCTION MANAGER. 1. THE HVAC CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE MECHANICAL SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING:(REFER TO RESPONSIBILITY SCHEDULE FOR EXACT RESPONSIBILITIES) HVAC UNITS, EQUIPMENT, AND APPURTENANCES. DUCTWORK, FITTINGS, DAMPERS, AND INSULATION. HYDRONIC PIPING AND INSULATION (AS APPLICABLE, REFER TO PLANS). REFRIGERANT PIPING (AS APPLICABLE, REFER TO PLANS). DIFFUSERS, GRILLES, AND REGISTERS. CURBS AND STEEL FRAMING FOR SUPPORT (AS APPLICABLE, REFER TO PLANS). TESTING, ADJUSTING, AND BALANCING. OPERATIONS MANUALS. TEMPERATURE CONTROLS AND RELATED DIAGRAMS. SEQUENCES OF OPERATION. CONNECTION TO ANY LANDLORD ENERGY MANAGEMENT SYSTEM. 3. BEFORE STARTING WORK, THIS CONTRACTOR SHALL EXAMINE THE ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL PLANS AND SPECIFICATIONS TO SEQUENCE, COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE HVAC SYSTEM, MATERIALS, AND EQUIPMENT WITH OTHER CONTRACTORS TO AVOID INTERFERENCES AND CONFRONTATIONS. 1. PRIMARY HEATING, VENTILATION AND AIR CONDITIONING UNITS. A. PRIMARY HEATING, VENTILATION, AND AIR CONDITIONING UNITS ARE TO BE BY CARRIER CORPORATION AS SCHEDULED. ALL COMPRESSORS ARE TO INCLUDE A 5 -YEAR EXTENDED WARRANTY. B. EQUALS EQUIPMENT AS MANUFACTURED BY TRANE OR YORK IS ACCEPTABLE. C. ALL EQUIPMENT SHALL BE COMPLETE IN EVERY RESPECT WI1'.I ALL DEVICES, APPURTENANCES, AND ACCESSORIES PROVIDED TO MEET THE DESIGN INTENT AND OPERATION OF THE SYSTEMS SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN. D. EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. ALL AIR CONDITIONING EQUIPMENT MUST HAVE A CONDENSATE DRAIN AND BE TRAPPED IN ACCORDANCE WITH MANUFACTURERS DATA. SEE DRAWINGS FOR ADDITIONAL DETAILS. E. SECONDARY DRAIN PANS ARE REQUIRED TO BE INSTALLED FF.NEATH ALL INDOOR AIR CONDITIONING EQUIPMENT WITH THE EXCEPTION OF VAV BOXES. SECONDARY PANS ARE TO PROTECT ENTIRE UNIT. PROVIDE CONDENSATE PUMPS, AS REQUIRED. CONDENSATE SHALL BE DIRECTED TO MOP SINK OR AS SPECIFIED ON PLANS. 2. VIBRATION ISOLATION DEVICES A. VIBRATION ISOLATION DEVICES SHALL BE PROVIDED IN ALL SUPPORTS BETWEEN VIBRATING EQUIPMENT (FANS, ROOFTOP UNITS, Alf HANDLERS, FAN POWERED VAV BOXES, ETC.) AND STRUCTURE. B. VIBRATING EQUIPMENT HUNG FROM STRUCTURE SHALL BE ISOLATED WITH RUBBER AND SPRING DEVICES. VIBRATING EQUIPMENT SUPPORTED FROM FLOOR OR DECK SHALL BE ISOLATED WITH HOUSED SPRING MOUNT DEVICES. C. EXAMINE DEAD LOAD AND OPERATING LOAD CONDITIONS ' SELECTING DEVICES. ADJUST FOR PROPER AUGNMENT AND LOADING. AVOID "GROUNDING" THE ISOLATOR. D. CHECK HANGER ROD SIZE FOR ALLOWABLE LOADS AT P. E ' ":...:TONG DEVICE AND AT THE UPPER AND LOWER ATTACHMENTS TO STRUCT, DUCTS, EQUIPMEH f, ETC. E. CONSULT MANUFACTURER FOR APPLICATION DATA. A. THIS CONTRACTOR WILL PROVIDE ALL NECESSARY CURBS AND STEEL FRAMING REQUIRED TO INSTALL ALL HVAC EQUIPMENT AS DESCRIBED OR IMPLIED ON THE DRAWINGS. CURBS SHALL BE A MINIMUM OF 14" IIIGH, OF THE SAME MANUFACTURER OF THE EQUIPMENT SUPPORTED. 'NSW _ATE UNDER THE COMPRESSOR SECTION TO PREVENT CONDENSATION. AU.. CURBS MUST BE INSTALLED SO THAT TOP OF CURBS ARE "DEAD" LEVEL. ALL PENETRATIONS OF EXISTING STRUCTURE SHALL BE DONE IN ACCORDANCE TO THE LANDLORD'S GUIDELINES AT THIS CONTRACTOR'S EXPENSE. 1. NO DUCTWORK SHALL BE FABRICATED PRIOR TO APPROVAL BY THE TENANT'S CONSTRUCTION MANAGER. SIGNIFICANT DEVIATIONS FROM DESIGN MUST BE APPROVED BY TENANT'S CONSTRUCTION MANAGER PRIOR TO FABRICATION OR INSTALLATION. ALL DUCT MAINS ARE TO BE RECTANGULAR UNLESS NOTES OTHERWISE. ALL DUCT BRANCHES TO DIFFUSERS ARE TO BE ROUND RIGID DUCT. (FLEXIBLE DUCT CONNECTIONS TO THE DIFFUSER ARE NOT TO EXCEED 5-0"). 2. EXCEPT AS OTHERWISE INDICATED, FABRICATE AND INSTALL RECTANGULAR DUCTS WITH GALVANIZED SHEET STEEL, IN ACCORDANCE WITH SMACNA "I NAC DUCT CONSTRUCTION STANDARDS" OF THE LATEST EDITION. CONFORM TO THE REQUIREMENTS IN THE REFERENCED STANDARD FOR METAL THICKNESS, REINFORCING TYPES AND INTERVALS, TIE ROD APPLICATIONS, AND JOINT TYPES AND INTERVALS. 3. EXCEPT WHERE OTHERWISE INDICATED, CONSTRUCT DUCT SYSTEMS TO THE FOLLOWING PRESSURE CLASSIFICATIONS: (VERIFY WHETHER RETURN OR EXHAUST DUCT IS POSITIVE OR NEGATIVE PRESSURE). A. SUPPLY DUCTS: 2 INCHES WATER GAUGE, POSITIVE PRESSURE B. RETURN AND EXHAUST DUCTS: 2 INCHES WATER GAUGE, NEGATIVE PRESSURE. PRESSURE TEST DUCTS FOR LEAKAGE. REMAKE LEAKING JOINTS AND APPLY SEALANTS AS REQUIRED TO FABRICATE A SYSTEM THAT DOES NOT EXCEED 5% LEAKAGE OR LESS AS STATED BY PRESSURE CLASS RATINGS IN SMACNA STANDARDS. 4. AS A MINIMUM, CROSSBREAK ALL FLAT SURFACES OR REINFORCE WITH A BEAD APPROXIMATELY 3/B" WIDE X 3/16" DEEP ON 12" CENTERS TO PREVENT VIBRATIONS. 6. INSTALL RIGID ROUND AND RECTANGULAR METAL DUCT WITH SUPPORT SYSTEMS INDICATED IN SMACNA STANDARDS. SUPPORT HORIZONTAL DUCTS WITHIN 2 FEET OF EACH ELBOW AND WITHIN 4 FEET OF EACH BRANCH INTERSECTION USING DOUBLE STRAP HANGERS ON EACH SIDE OF FITTING. SUPPORT VERTICAL DUCTS AT A MAXIMUM INTERVAL OF 16 FEET AND AT EACH FLOOR. NO WOOD SHALL BE USED TO SUPPORT OR BRACE DUCTS. PROVIDE SWAY AND SEISMIC BRACING AS REQUIRED BY STATE AND LOCAL CODES OR BY LANDLORD. 7. WHERE DUCTS PASS THROUGH ROOFS AND FLOORS, PROVIDE AS MINIMUM 1- 1/2"X1-1/2" X1 /8" STEEL ANGLE FRAMES AT EACH SIDE OF OPENING. THE ANNULAR SPACE BETWEEN DUCT AND ANGLE FRAMES SHALL BE CAULKED WITH SILICONE SEALANT OR FIREPROOFED AS REQUIRED BY ASSEMBLY FIRE RATING. 8. ALL TRAVERSE JOINTS AND SEAMS IN SUPPLY AIR DUCT SHALL BE SEALED AIR TIGHT WITH DAP CMC DUCT SEALER. JOINTS ALSO SHALL BE RIVETED OR CONNECTED WITH SHEET METAL SCREWS. 9. SOFT ELASTOMER BUTYL GASKET WITH ADHESIVE BACKING SHALL DE USED TO SEAL FLANGED JOINTS. 10. DUCT TRANSITIONS SHALL NOT EXCEED 30 DEGREES SLOPE EXCEPT AS SPECIFICALLY NOTED OTHERWISE. 11. PROVIDE ACCESS TO ALL MOTORIZED DAMPERS, FIRE DAMPERS, CONTROLS, AND OTHER ITEMS IN DUCTWORK THAT REQUIRE SERVICE OR INSPECTION. IF THE ACCESS PANEL LOCATION IS EXPOSED TO THE SALES AREA, IT MUST BE APPROVED BY THE TENANT'S CONSTRUCTION MANAGER PRIOR TO INSTALLATION. LAY -IN SUPPLY AND RETURN AIR DIFFUSERS, GRILLES AND REGISTERS WITH PLASTER FRAMES MAY BE USED AS ACCESS LOCATIONS. A. FLEXIBLE COLLARS SHALL BE PROVIDED IN ALL CONNECTIONS BETWEEN VIBRATING EQUIPMENT (FANS, ROOFTOP UNITS, AIR HANDLERS, FAN POWERED VAV BOXES, ETC.) AND DUCTS OR CASINGS. ALSO, PROVIDE FLEXIBLE CONNECTIONS WHERE DUCTS CROSS BUILDING EXPANSION JOINTS. B. FLEXIBLE CONNECTIONS SHALL CONSTRUCTED OF NEOPRENE -- COATED FLAMEPROOF FABRIC. PROVIDE ADEQUATE JOINT FLEXIBILITY TO ALLOW FOR MOVEMENT AND PREVENT THE TRANSMISSION OF VIBE ATION. C. FLEXIBLE CONNECTION IS TO BE RATED FOR THE OPERATING PRESSURE OF THE SYSTEM. 13. FIRE DAMPERS (IF REQUIRED) A. PROVIDE PRIMARY FIRE DAMPERS WHERE INDICATED OR REQUIRED BY CODES. DAMPERS SHALL BE DESIGNED FOR HORIZONTAL OR VERTICAL FLOW OF AIR AS REQUIRED. FIRE DAMPERS SHALL BE UL LABELED B. FIRE DAMPERS SHALL HAVE THE BLADES OUT OF THE AIRSTREAM AND A 1650'F FUSIBLE UNK, TYPE A, AS MINIMUM. C. PROVIDE ALL NECESSARY FRAMING AND SLEEVES FOR DAMPER MOUNTING PER UL AND CODE REQUIREMENTS. D. PROVIDE DUCT ACCESS DOORS IN AN ACCESSABLE LOCATION FOR ALL FIRE DAMPERS. DOOR IS TO BE 20 GA GALVANIZED DOOR WITH QUICK - OPENING LATCH AND PIANO HINGE. 14. FLEXIBLE AIR DUCT A. FLEXIBLE AIR DUCT SHALL BE 1" INSULATED CLASS 1 AND RATED FOR THE OPERATING PRESSURE OF THE SYSTEM. DUCT CONSTRUCTION MATERIAL (PLASTIC, CLOTH, ALUMINUM) MUST ADHERE TO LOCAL CODES AND LANDLORD'S REQUIREMENTS AND BE INCLUDED AS SUCH IN THE BID. B. FLEXIBLE AIR DUCT MAY ONLY BE USED IN VERTICAL APPLICATIONS WITH PRIOR APPROVAL FROM TENANT'S CONSTRUCTION MANAGER. C. FLEXIBLE DUCT SHALL NOT EXTEND OVER 5' -0" IN LENGTH AT ANY ONE LOCATION. 15. SUPPLY AIR TAKE -OFF FITTINGS A. PROVIDE CONICAL OR "BELL - MOUTH" TAKE -OFFS FROM MAIN DUCTWORK TO ROUND BRANCHES. INSTALL PER MANUFACTURER'S INSTRUCTIONS. B. PROVIDE 45' RECTANGULAR TAKE -OFFS FROM MAIN DUCTWORK TO RECTANGULAR BRANCHES. 16. DAMPERS A. PROVIDE MANUAL LOCKING QUADRANT VOLUME CONTROL DAMPERS WITH HANDLE OPERATORS IN EACH BRANCH DUCT AND AS SHOWN ON PLANS TO FACILITATE AIR BALANCING. B WHERE ACCESS TO BALANCING DAMPER IS RESTRICTED, YOUNG'S REGULATORS SHALL BE USED. C. ALL RECTANGULAR DAMPERS IN OUTSIDE AIR, RELIEF AIR, OR RETURN AIR DUCTS ARE TO BE OF OPPOSED BLADE TYPE. ALL OUTSIDE AIR DUCT DAMPERS MUST ALSO BE OF THE LOW LEAKAGE TYPE. D. ALL MOTORIZED DAMPERS NOT FURNISHED WITH EQUIPMENT ARE TO BE HONEYWELL DAMPERS. 17. DIFFUSERS, GRILLES, AND REGISTERS A. PROVIDE DIFFUSERS GRILLES AND REGISTERS AS SCHEDULED. DEVICES TO BE COMPLETE WITH DAMPERS FRAMES AND ALL ACCESSORIES. FINISH AS INDICATED. B. INSTALL ALL AIR DEVICES AS LOCATED ON THE ARCHITECTURAL REFLECTED CEILING PLAN. C. APPROVED MANUFACTURERS: NUS IS SPECIFIED, EQUALS BY METALAIRE OR KRUEGER IS ACCEPTABLE. 18. DUCTWORK INSULATION A. INSTALL INSULATION PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS, AND IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES. INSULATION MUST COMPLY WITH NFPA 90A. B. DUCT SIZES SHOWN ON DRAWINGS ARE INSIDE CLEAR DIMENSIONS. INSULATE SUPPLY AND RETURN AIR RECTANGULAR DUCTWORK WHERE SHOWN ON PLAN. DUCTWORK SHALL BE INTERNALLY INSULATED WITH 1" THICK, 1 -1/2 LB. DENSITY LINER (C =0.28 © 75F). LINER IS TO HAVE A COATED SURFACE EXPOSED TO AIRSTREAM TO PREVENT EROSION. APPLY ADHESIVES AND MECHANICAL FASTENERS AS RECOMMENDED BY SMACNA AND THE MANUFACTURER TO PREVENT LINER SEPARATION FROM THE DUCT. ALL TRANSVERSE EDGES TO BE COATED WITH ADHESIVE. C. ALL ROUND AND OUTSIDE AIR DUCTWORK ABOVE THE CEILING SHALL BE EXTERNALLY INSULATED WITH A MINIMUM OF 1 "THICK, 1 -1/2 LB. DENSITY (R =5.6) DUCT WRAP WITH VAPOR BARRIER, VAPOR BARRIER IS TO BE MAINTAINED THROUGHOUT DUCT SYSTEM. ALL JOINTS MUST BE TAPED SO THAT NO INSULATION FIBER IS VISIBLE. EXTEND DUCTWORK INSULATION WITHOUT INTERRUPTION THROUGH WALLS, FLOORS, AND SIMILAR PENETRATIONS. D. ALL INSULATION SHALL HAVE A FLAME SPREAD RATING OF NOT MORE THAN 25 AND A SMOKE DEVELOPED RATING OF NO HIGHER THAT 50 WHEN TESTED IN ACCORDANCE WITH ASTM C 411, OR AS REQUIRED BY LOCAL CODES. 20. SYSTEM CLEANOUT A. DUCTWORK AND AIR HANDLING EQUIPMENT IS TO BE CLEANED OUT AND BLOWN OUT BEFORE PAINTING IS STARTED BY THE GENERAL CONTRACTOR. B. FILTERS MUST BE IN UNITS AT ANY TIME FANS ARE OPERATED. H. SYSTEM TESTING, ADJUSTING, AND BALANCING 1. TESTING, ADJUSTING AND BALANCING OF ALL WORK SHALL BE MADE BY AN INDEPENDENT CONTRACTOR WHO IS CURRENTLY LICENSED ASSOCIATED AIR BALANCING COUNCIL (AABC) OR NATIONAL ENVIRONMENTAL BALANCING BUREAU (NEBB) BALANCING CONTRACTOR. NO OTHER BALANCE REPORTS WILL BE REVIEWED OR ACCEPTED. ALL BALANCING WORK MUST BE COMPLETE AND DONE IN ACCORDANCE WITH THE MOST RECENT STANDARDS OF THEIR SOCIETY. PAYMENT OF ALL COSTS FOR TESTING SHALL BE MADE BY THE HVAC CONTRACTOR. 2. THE HVAC CONTRACTOR SHALL INSTALL NEW FILTERS IN ALL UNITS PRIOR TO THE AIR BALANCE. THE COMPLETE AIR BALANCE SHALL TAKE PLACE WITH OUTSIDE AIR DAMPERS IN MINIMUM POSITION. 3. BALANCE AIR AND WATER QUANTITIES TO WITHIN + 5% OF THAT INDICATED ON THE DRAWINGS. ANY REQUIRED CHANGES IN SHEAVES, BELTS, PULLEYS, OR THE ADDITION OF DAMPERS REQUIRED TO ACHIEVE SPECIFIED FLOW RATES SHALL BE PERFORMED BY THE HVAC CONTRACTOR WITH NO ADDITIONAL COST TO THE TENANT. 4. THE BALANCE REPORT SHALL INCLUDE AS A MINIMUM THE FOLLOWING INFORMATION: A. AABC OR NEBB CERTIFICATION NUMBER AND SIGNATURE OF BALANCING CONTRACTOR. B. INSTRUMENTATION LIST WITH LAST CAUBRATION DATES. C. MAKE AND MODEL NUMBERS OF ALL HVAC EQUIPMENT TESTED. D. AIR CFM AND STATIC PRESSURE READINGS (DISCHARGE AND SUCTION) AS MEASURED BY PITDT TUBE DUCT TRAVERSE AT THE UNIT. E. MOTOR NAMEPLATE DATA WITH ACTUAL FIELD VOLTAGE AND AMPERAGE READINGS FOR EACH LEG. F. MOTOR AND FAN RPMS, SHEAVE SIZES AND BELT SIZES. G. OUTSIDE, RETURN, MIXED AND SUPPLY AIR TEMPERATURES AT FULL COOLING. H. WATER BALANCE DATA INCLUDING GPM WITH INLET AND OUTLET TEMPERATURE AND PRESSURE READINGS (WHERE APPLICABLE). I. MAKE AND MODEL NUMBERS OF ALL AIR DISTRIBUTION EQUIPMENT. J. FINAL BALANCED AIR VOLUMES AT ALL OUTLETS (INCLUDING RETURNS WHERE DUCTED). K. INDEXED PLAN WITH DIFFUSER AND RETURN LOCATIONS. 5. ALL CONTROL SEQUENCES SHALL BE TESTED (INTERLOCKED EQUIPMENT, SMOKE DETECTORS, SMOKE EVACUATION, ECONOMIZER, ETC.) AND OPERATING STATUS RECORDED IN THE REPORT. 6. THREE COPIES OF THE BALANCE REPORT SHALL BE SUBMITTED THROUGH THE GENERAL CONTRACTOR TO THE TENANT'S CONSTRUCTION MANAGER FOR APPROVAL. 7. THE BALANCING CONTRACTOR SHALL PERFORM ALL APPLICABLE TESTING AND BALANCING FUNCTIONS REQUIRED FOR THE SYSTEM DESIGNED IN THESE DRAWINGS. THE BALANCING CONTRACTOR SHALL RECHECK ANY ITEMS THAT THE TENANT DEEMS NECESSARY AT NO ADDITIONAL COST TO THE TENANT. 8. FINAL BALANCE REPORT SHALL BE INCLUDED IN THE OPERATION & MAINTENANCE MANUALS. L FINAL HVAC INSPECTIONS 1. ASIDE FROM NORMAL INTERIM INSPECTIONS OF WORK IN PLACE, THE TENANT SHALL HAVE THE RIGHT TO AN INDEPENDENT HVAC CONTRACTOR INSPECT THE FINISHED HVAC INSTALLATION UPON COMPLETION FOR COMPLIANCE WITH THE PLANS, SPECIFICATIONS, AND CODES. THE INSTALLING CONTRACTOR WILL BE RESPONSIBLE TO BRING ALL ITEMS REPORTED BY THE INDEPENDENT HVAC CONTRACTOR UP TO PLANS AND SPECIFICATION REQUIREMENTS AT NO COST TO TENANT. . i_ "REVIEWED FOk- .. CODE COMPLIANCE APPR Vgi 4 MAY 12 ?IW0/ City Of Tukwila RECEIVED CITY OF TUKWILA MAY 0 s 2008 PERMIT CENTER MI II 04/01/08 04/01/08 No. Date DO NOT SCALE DRAW/NOS. MOM Retell No. 740 9869 ID001 010 watt 11)AegL.3" DAVID A. UDKO ARCHITECT TENANT IMPROVEMENTS CONSULTING 11881 NORTH 113th WAY SCOTTSDALE. AZ. 85259 (480) 614 - -3385 bus (480) 614-0209 fax l email: davidaudkow@cox.net Ernpho5I, On Excellence M•Retail Engineering, Inc. 750 Drooksedge Blvd. Westerville, Ohio 43081 PHONE 614.818.2323 p FAX 614.818.2337 70809 �/�p/� 008 shield Working Drawing Review _ Approved Approved as Noted 0 Resubmit These drawings have been reviewed for general design Intent only. All actual field conditions are required to be verified by the Tenant's Architect and /or Contractor. Tenant Is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings Is required to be kept on the job site _atII times. ISSUED TO LANDLORD ISSUED TO CLIENT RsNWon igned Dale Contractor must varliy M job d*nan ons, draelllpe, ddsls and e pedlioa6one and report ini diecrepwories b advent before proceeding with work. Watt wit not be P. for erry anon and ondesione not reported by Gonad Cont BEN BRIDGE JEWELER SOUTH CENTER MALL 81 SOUTHCENTER MALL LEVEL 1, UNIT #740, TUKWILA, WA 98188 MECHANICAL SPECIFICATIONS Dais JANUARY 2007 Checked Scats AS NOTED Signetuno Dale 4/13/08 ect ect Drawn TM Owning not b be teed for oonabraBon ud1 aouderalpra L The contents of this drawkp w the copyright °watt and are not to be tepodlroed to who s or In pert *about the Inprele Wien ocneent °drs oopyrfpbt maw. Walt will not aeawni naporielbilly teeny negipent e rnra or onduIk I . • • • Project X1511 OF 7 SHEETS T 410.804.9884 800 Dsplew Avenue F 410.864.1008 Tomb, ON w weibntoom Canada PAM 3R7 wart Into nlMwni ku en Bwloy drouPangr.y