Loading...
HomeMy WebLinkAboutPermit M08-139 - WESTFIELD SOUTHCENTER MALL - VITAMIN WORLDVITAMIN WORLD 1119 SOUTHCENTER MALL M08.139 Parcel No.: 6364200010 Address: Suite No: Tenant: Name: Address: 1119 SOUTHCENTER MALL TUKW VITAMIN WORLD 1119 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: KENT FAHEY Address: 3019 HOLLINWELL DR , KATY TX Contractor: Name: TRI MECHANICAL INC Address: P.O. BOX 444 , REDMOND WA Contractor License No: TRIMEI *044KB DESCRIPTION OF WORK: MODIFY EXISTING SYSTEM, NEW VAV BOX AND DUCTWORK Value of Mechanical: $5,000.00 Type of Fire Protection: SPRINKLERS /AFA Furnace: <100KBTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC -10/06 Citylif Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tulcwila.wa.us MECHANICAL PERMIT EQUIPMENT TYPE AND QUANTITY 0 0 0 0 0 1 0 0 0 0 0 0 0 0 * *continued on next page ** M08 -139 • Permit Number: Issue Date: Permit Expires On: Phone: Phone: 800- 556 -8641 Phone: 425 391 -6016 Expiration Date: 05/02/2009 M08 -139 06/02/2008 11/29/2008 Fees Collected: $226.13 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 1 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 06 -02 -2008 Permit Center Authorized Signature: doc: IMC -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • Permit Number: M08 -139 Issue Date: 06/02/2008 Permit Expires On: 11/29/2008 n n(� \ -�J J --� g� Date: ' �J- -D I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. Signature: Date: a - o2 Print Name: / it CD/ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M08 -139 Printed: 06-02 -2008 Parcel No.: 6364200010 Address: 1119 SOUTHCENTER MALL TUKW Suite No: Tenant: VITAMIN WORLD 1: ** *BUILDING DEPARTMENT CONDITIONS * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: M08 - 139 Status: ISSUED Applied Date: 05/12/2008 Issue Date: 06/02/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 11: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 12: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 13: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 14: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 15: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) doc: Cond -10/06 M08 -139 Printed: 06 -02 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 17: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 18: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 19: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 20: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** M08 -139 Printed: 06 -02 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: _/ 7 Date: Print Name: / (.Grime / doc: Cond -10/06 M08 -139 Printed: 06-02 -2008 Name: V..tzt -kr CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 littp://www. ci. tukwila. Wa. us Mailing Address:` L(1,O I k,k) /?- NI r�. Mailing Address: (L t E -Mail Address: l'r• CD/v1 Contact Person: E -Mail Address: Contractor Registration Number: Company Name: )1. S l \A I Tt, &Z)'L..C.. Mailing Address: 00 7 2O 1Js) 3 'ai00 Contact Person: .y�S �;?►R -t V irt- trCAZJL_ E -Mail Address: Contact Person: E -Mail Address: Q.\Applicanons\Fomts- Applications On Line'3 -2006 - Permit Application.doc Revised: 9 -2006 bh Building Permit No. X) 8 -(„17 Z Mechanical Permit No. MO Plumbing /Gas Permit No. Wag- P 1-( 8 Pub Works Permit No. Project No. ) ( rn — I14 2 r office iise only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** ,SITE LOCATION King Co Assessor's Tax No.: L 3 (.pii W 0©( 0 Site Address: < < l 9 S - j"«"`�•" 1 " `tt--� Suite Number: Tenant Name: ('r- p...mo vu New Tenant: Property Owners Name: tiV r Fit. C s;23' City c State Day Telephone: 800 2 'S(1 - Ste I. 1 CONTACT PERSON do we contact. when your permit is ready to be issued Floor: Yes ❑ ..No City 1 State Zip Fax Number: 2$ i GENERAL; CONTRACTOR-1NFORMATION :( Contractor fordMechanicai(pg 4) for Plumbing Gas Piping (pg 5)) Company Name: Dot Tr) Qa r Mailing Address: City Day Telephone: Fax Number: Expiration Date: State Zip ARCHITECT OF. RECORD - All plans must be wet stamped by. Architect of Record Pg-LioGi VC "400 CR- Cit State Zip Day Telephone:BO. 7J,0S 7-4 ( S Fax Number: 81 ` 483 -- E, ENGINEER' RECORD - 'All.plans must. be wet stamped by Engineer of Record Company Name: Mailing Address: City Day Telephone: Fax Number: Page 1 of 6 State CPO z-S Zip Zip 1 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Q ty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser 3 -15 I-IP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat i 15 -30 HP /1,000.000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to "N Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm/Ind MECHANICAL PERMIT INFORMATION - 206431 -3670 MECHANICAL CONTRACTOR INFORMATION TJ D L i r Company Name: 110 Mailing Address: State Zip PP 00 City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $ ri 0 Scope of Work (please provide detailed information): In &O r 15 Si' ( (-' : Sr', Ertt) W-Fic\t (c)( pL9 C lr g-al✓ Use: Residential: New .... ❑ Replacement Commercial: New .... ❑ Replacement Fuel Type: Electric Gas .... Other: Indicate type of mechanical work being installed and the quantity below: QA Applications On Line' -2006 - Pemit Application.doc Revised 9 -2006 bit Page 4 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this ;application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY TILE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: �� eA- Print Name: <-421.4 Mailing Address: D t H r L S ( i::> . City Q:Wpphcanons\Fonns- Applications On Line: -2006 - Permit Application.doc Revised: 9 -2006 bh Datet`' (� Day Telephone: S © ® S5c, .tat) `-& I State Zip I Date Application Accepted: o fd Date Application Expires: Staff Initials: Page 6 of 6 RECEIPT NO: R08 -02410 Initials: WER User ID: 1655 Payee: JOSEPH M. MCINTYRE SET TRANSACTIONS: Set Member Amount ACCOUNT ITEM LIST: Description City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us SET RECEIPT Payment Date: 07/03/2008 Total Payment: 118.00 SET ID: 0703 SET NAME: VITAMIN WORLD REVISIONS EL08 -551 58.00 ga2k8,42ZU 60.00 TOTAL: 118.00 TRANSACTION LIST: Type Method Description Amount Payment Check 644 118.00 TOTAL: 118.00 ELECTRICAL PERMIT - NONR MECHANICAL - NONRES Account Code Current Pmts 000.322.101.00.0 58.00 000.322.102.00.0 60.00 TOTAL: 118.00 4420 07/03 9711 TO I rat- 118.00 Parcel No.: 6364200010 Permit Number: M08 -139 Address: 1119 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 05/12/2008 Applicant: VITAMIN WORLD Issue Date: Receipt No.: R08 -01885 Initials: WER Payment Date: 06/02/2008 11:58 AM User ID: 1655 Balance: $0.00 Payee: TRI- MECHANICAL TRANSACTION LIST: Type Method Descriptio Amount Payment Check 15516 180.90 ACCOUNT ITEM LIST: Description MECHANICAL - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Account Code Current Pmts 000.322.102.00.0 180.90 Total: $180.90 Payment Amount: $180.90 3120 06/02 9711 TOTAL 180.90 doc: Receiot -06 Printed: 06-02 -2008 Parcel No.: 6364200010 Permit Number: M08 -139 Address: 1119 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 05/12/2008 Applicant: VITAMIN WORLD Issue Date: Receipt No.: R08 -01561 Payment Amount: $45.23 Initials: WER Payment Date: 05/12/2008 11:53 AM User ID: 1655 Balance: $180.90 Payee: RETAIL PERMIT SERVICES TRANSACTION LIST: Type Method Descriptio Amount Payment Check 8876 45.23 ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Account Code Current Pmts 000/345.830 45.23 Total: $45.23 2284 05/12 9711 TOTAL 734.78 doc: Receiot -06 Printed: 05-12 -2008 Project: , ) / i Type of Inspection: Address; //! A / Date Called: Special Instructions: Date Wanted z / el? a Requester: Phone No: INSPECTION NO. INSPECTION RECORD Retain a copy with permit MD V- rap PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 9— 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 'Approved per applicable codes. El Corrections required prior to approval. ' COMMENTS: ' 1 4 t . Inspector: , Date: �� '/ l $60.0 I NSPE paid 6300 Southcenter El CTION FEE REQUIRED. Prior to inspection, fee must be p thcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Project: vt.1 th 00 Type of Inspection: ex,,_sn. + aw l Address: 11 19 YY)40.... Date Called: Special Instructions: Date Wanted: -7 /1 lbk a.m. p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit MOT - 131 PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 OM MENTS: \VW - 1. � �� � � M,R.'S ho . I In - Ca`SQOf rv2S lAnii- LA L' tN • Approved per applicable codes. Corrections required prior to approval. Inspector: 'Date: 7//7/e ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Project • V/ / / ,7-7%/v rld Type of spection: /.? 67/61/ Al Address: /// c in A- / / Date Called: Special Instructions: Date ynted� �� ,.. p.m. Requester: Ph No: z 5 - - 7 ? -( ) INSPECTION RECORD Retain a copy with permit PERMIT NO. J oL 7 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 0 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: 04 Foe' Ce p, Ver 145d , f51let. Date: 7 / 9 47 El $60. EINSPECTION FEE REQUIRED. Prior to inspection, fee must be pai t 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: � Projept;r. 4414'11 ,Jl ✓ J ( Typ f Inspe ctjon: • Address;,. �q f, Date Called`. Special Instructions: Date W nted: _..1 �� —QG.� (ate„ p.m. Requester: Phone No: Q25 -373 �.-- -- INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION V- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 - 3670, El Approved per applicable codes. Corrections required prior to approval. COMMENTS: P7 OL T% i /SaJzJe } Date / $60.9 JI INSPECTION FEE REQUIRED. Prior to inspection, fee must be paid Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Pro.'ec : �,�,; G6.../6446( Type ns ect' n: I�' � it it /4 rg / 7 , 7 // Date Called: Special Instructions: • Date Wapted: 63- / d - e a.m. P.m. Requester: Phon No: Retain a copy with permit PERMIT NO. CITY OFTUKWILA BUILDING DIVISION IQ 's „ 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION NO. • 1.. INSPECTION RECORD / #1l a ? '-1 Approved per applicable codes. EJ Corrections required prior to approval. COMMENTS:,.,. El $6f'.00 paid a Receidt No.: 'Date: Date' G a8 NSPECTION FEE REQUIRED.. Prior to inspection, fee must be 300 Southcenter Blvd), Suite 100. Call to schedule reinspection. Project: V,rik t , 4 `rJo i_ 0 Type of Inspection: F 4 7 i A- Address: t t < 5C MALL- Suite #: Contact erson: Special Instructions: Phone No.: Needs Shift Inspection: Sprinklers: .. -_ Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: A pproved per applicable codes. Inspector: INSPECTION NUMBER CITY OF TUKWILA FIRE DEPARTMENT ( j a y /4 1 2 INSPECTION RECORD Retain a copy with permit Date: Wz i /08 ()6- f? �o8 -77Z- PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Corrections required prior to approval. COMMENTS: A-O t) (2 4. SS O(I - o'rL1- i) - 0 (L..... . f rs.. $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from e City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 Cooling Equipment Schedule E Wp ID Brand Name' Model No.' Capadty Btunl Total CFM OSA CFM or Econo? SEER or EER IPLV Location 4N -(G tr - 45 AA - } kS,LPOo Qsi a WA WA 4 / 4 re s ic, N �A MP Heating Equipment Schedule EMAIL ID Brand Name' Model No.' Capacity' Btu/h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Effidency $ eon.( I U D tI t ; - 1 100 - p 5 i /a ` Applicant Phone: N �A MP Fan Equipment Schedule Equip. ID Brand Name' Model No.' CFM SP ' HP/BHP Flow Control' Location of Service Ye- I $ eon.( I U D tI t ; - 1 100 - p 5 i /a P-es -r 64.t Applicant Phone: N �A MP Project Info Project Address v, t tilthviA to 11/0121.(1 r Sel,)T1 CEn1- Ma-Date 5/, -/OS I ( Lq SOfJ't c.€ # T 2 . AA ACA... For Build g Use REVIEWED FOB -it C fMPLIM TU l4--IA) (LA t w/4 9:2( It. E5 Applicant Name: Applicant Address: • Applicant Phone: N �A CITY OF TUKWILA - BUILDING DIVISION 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Summary MECH -SUM 2006 Watninpton State Na vedda4ial Energy Cade Camptlance Forms Project Description Briefly describe mechanical system type and features. • fides Plans • Fr i copy r MOO. Oo . MO 134 l MAY 2 2 2008 Reeked Mt 2X7 CE 1�1► e In clude documentation requiring compliance with commissioniSig requ(ptttaentalSectionalitt. j TukWif� n ) r r. r8C 0 Systems �j�J11- .1J1IVVl Lia �N Compliance Option See System • 0 Complex System Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill In the required information below. CEIVED ( ,142 PERMIT CENTER System Description See Section 1421 for full description of Simple System qualifications. If Heating/Cooling or Cooling Only: Constant vol? ❑ Split system? ❑ Air cooled? ❑ Packaged aye? ❑ <20,000 Btuh? ❑ Economizer included? • If Heating Only: g 0 <5000 dm? ❑ <10% outside air? Mechanical Summary (back) MECH -SUM CITY OF TUKWILA - BUILDING DIVISION 2006 Washington State Nonresidential Energy Code Compliance Form Decision Flowchart Use this flowchart to determine it project qualifies for Simple System Option. if not, either the Complex System or Systems Analysis Options must be used. Heating Only Reference Section 1421) Heating/Cooling or Cooling Only Yes Reference Section 1423 Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance In determining which Complex Systems requirements are applicable to this project. ► ec apical Permit Plans axe wasmese scab rnnuusrde rwsycxd, Cpnpim7,f®. t MECH -CHK s.w.d Project Addresser �� ( Address , cam u1o12.4A Ili J So1lS11l•1rw i 1 iA Date I 5 requirement In the The following Information Is necessary to check a mechanical permit application for compliance with the mechanical Washington State Nonresidential Energy Code. Applicability (yes no, nor) Code Section ICorr 'information Required Location ( on Plans I Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) . . 1411 EgWpmeM petfOrlmellfi A 1411.4 Pkg. elec. htg.& dg. List heat pumps on schedule &/A 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency ,4 / 1411.1 Combustion htg. Indicate Intemdttent ignition, flue/draft damper d Jacket loss 1412 HVAC controls Y6 s 1412.1 Temperature zones Indicate locations on plans 45 Al/A 1412.2 Deadband control Indicate 8 degree deadbend mean= O 1412.3 Humidity control indicate humidlatat . 7 7 1412.4 setback Indicate thermostat with night setback and dtiL day types d a,� k / 1412.4.1 Dampers Indicate damper location and auto. contras & max. leakage N 1 / * 1412.4.2 Optimum Start Indicate optimum start controls a/A 1412.5 Heat pump control Indicate microprocessor on thermostat schedule riKP 1412.8 Combustion hag. Indicate modWaling or staged control A /A 1412.7 Balancing Indicate balancing features on plans k / A 1412.8 Ventietlon Control Indicate demand control ventilation for high-occupancy areas - fss 1422 Thermostat Interlock Indicate thermostat Warlock on plans 1 ti 441 1423 Economizers Equipment schedule /A 1413 Air sconombers 1413.1 Econo Operation Indicate 100% capability on schedule 1413.1 W it Eeono Operation indicate 100% capah y at 48 degF db & 4o deg F cob 1413.2 Water Econo Doc indicate dg toad & water sconce & clg tower performance Integrated operation Indicate capability for partial cooling 1413.4 Hunfdftieatlon Indicate direct evep or fog atomization uW air economizer 1414 Ducting systems 1414.1 Duct sealing sealing necessary 1E3 1414.2 indicate Duct insulation I dicate R-velue of Insulation on duct IS 1415.1 Piping Insulation Indicate R -value of FuWation on piping AA- 3 ti /, 1418 Completion Requirements 1418.2.1 Commissioning Provide commissioning plan 1418.2.2-3 Sys.Bat & Func.Test Indicate air and water system balancing & functional testing 141824 Commissioning Indkete O&M manuals, record drawings, staff training 141825 Comm. Report Indicate requirements for prelim. & final camnisalonkng report 1434 Sepa rate air sys. Indicate separate systems on plans 1E-5 I 'biochemical Completed and attached Equipment schedule with types. (Summary Form (Input/output, efBde t y, clan, hp, economizer J 1M - 2 �i tltVlt,.`E WA I eft HI:A I INLa ANU HtA I tU tIiULki (bectione1440 - 1454) 1440 Service water Mg. -ice 1441 Elec water heater indicate RAO Ineuistlan under tank Y1 A, 3 lea 1442 Shut-off controls Indicate automatic shut-off P —1 les 1443 Pipe insulation Indicate ft-value of Insulation on piping NA - 3 4a 1452 Heat Pump COP . Indicate minimum COP of 4.0 "tom 1452 Heater Efficiency Indicate pool heater efficiency P -1 e4(d 1453 Pool heater centrals Indicate switch and 85 degree control 2008 Washl n State Nonresidential Ene Code Com . fiance Form DEPARTMENTS: Bu .iig Division Complete Comments: TUESITHURS ROk'1TING: Please Route REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 'EMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M08 -139 DATE: 06.24 -08 PROJECT NAME: VITAMIN WORLD SITE ADDRESS: 1119 SOUTHCENTER MALL Original Plan Submittal Response to Correction Letter# Response to Incomplete Letter # X Revision # 1 After Permit Issued Public Works n Structural ( �(G o FVLcftl ub Fire Prevention DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete Planning Division ❑ Permit Coordinator DUE DATE: 06 -26-08 Not Applicable n n Permit Center Use 'Only „ If INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Structural Review Required ❑ No further Review Required DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 07 -24 -08 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: ' DATE: Permit CenterUse Only I ; CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: M08 -139 DATE: 05 -12 -08 PROJECT NAME: VITAMIN WORLD SITE ADDRESS: 1119 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # DEPARTMENTS: Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28-02 PERMIT COORS COPY PLAN REVIEW /ROUTING SLIP n 511 kw - 644 - oe Fire Prevention Structural Incomplete Response to Incomplete Letter # Revision # After Permit Issued Planning Division ❑ Permit Coordinator DUE DATE: 05-1 5-08 DATE: DATE: Not Applicable TUES/THURS RO J TING: Please Route Structural Review Required ❑ No further Review Required Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DUE DATE: 06 -12 -08 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS STAFF INITIALS I ( )A-Or( Summary of Revision: kA sit cJ c. I pi Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS STAFF INITIALS I ( )A-Or( Summary of Revision: kA sit cJ c. I pi Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS STAFF INITIALS I ( )A-Or( Summary of Revision: kA sit cJ c. I pi Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS STAFF INITIALS I ( )A-Or( Summary of Revision: kA sit cJ c. I pi Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS STAFF INITIALS 1/4 ISSUED DATE M 141 STAFF INITIALS I ( )A-Or( Summary of Revision: kA sit cJ c. I pi I A nuf Received by: Received b : NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: PROJECT NAME: V i 4itm;... fAci SITE ADDRESS: \kkC( S -C - Ma�I REVISION LOG 4 uu PERMIT NO: I-lh- 13`� ORIGINAL ISSUE DATE: (0- 1- -Ot' ease print ease print ease print ease pnn please print Created: 8 -13 -2004 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # Er Revision # / after Permit is Issued Received at the City of Tukwila Permit Center by: e ntered in Permits Plus on (2 4) ' 4,--0 9 \applications\forms- applications on Iinelrevision submittal Sheet Number(s): / / /272 / 1' 3 "Cloud" or highlight all areas of revision including date of revisio Steven M. Mullet, Mayor Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: q2 `f /LJ' Plan ChecWPermit Number: T 7y — /N7 ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: V, Project Address: // /' c $ -z e /Jz- / Contact Person: /7//,-c_.,`- Phone Number: - c - cFPZ. - , b 7 / Summary of Revision: e e , / , / y 7 — V 1�s NED art OF TUKW SUN 2 4 2008 FZC:c.1IT CEN t-y` License Information License TRIMEI *044KB Licensee Name TRI MECHANICAL INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601709252 Ind. Ins. Account Id Received Date Business Type CORPORATION Address 1 1824 BOTH AVE Address 2 City BELLEVUE County KING State WA Zip 98005 Phone 4253916016 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 5/2/1996 Expiration Date 5/2/2009 Suspend Date Separation Date Parent Company Previous License Next License Associated License Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #6 CBIC LC0466 05/01/2006 Until Cancelled $12,000.00 03/09/2006 Business Owner Information Name Role Effective Date Expiration Date HILDERBRAND, KURT E 01/01/1980 JOHNSON, DAVE 01/01/1980 JENSEN, RONALD 01/01/1980 Look Up a Contractor, Electricn or Plumber License Detail Washington State Department of Labor and Industries General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. • Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= TRIMEI *044KB 06/02/2008 SYMBOL LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION SUPPLY AIR DIFFUSER SHADING DENOTES BLANK –OFF DUCT MOUNTED DIFFUSER SUPPLY OR RETURN AIR LINEAR DIFFUSER RETURN AIR GRILLE OR DUCT SUPPLY AIR DUCT RISE SIMILAR FOR RETURN AIR SUPPLY AIR DUCT DROP SIMILAR FOR RETURN AIR HIGH SIDE WALL LOW SIDE WALL MECHANICAL CONTRACTOR ELECTRICAL CONTRACTOR ( /1 1 r , \._./ L _ J _ ROOF MOUNTED EQUIPMENT AS NOTED CEILING EXHAUST FAN T– DENOTES THERMOSTAT S– DENOTES SENSOR TURNING VANES DUCT TRANSITIONS BRANCH DUCT WITH SPIN –IN FITTING AND VOLUME DAMPER F.D. – FIRE DAMPER DUCT SMOKE DETECTOR W W M r O a il%) J J JJ TV 1St HSW LSW M.C. E.C. — ■imam. 0 1. GENERAL HVAC NOTES GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR DEMOLITION AND REMOVAL OF EXISTING DUCTWORK, DIFFUSERS, GRILLES, CONTROLS, ETC., AS REQUIRED TO FACILITATE NEW INSTALLATIONS. 2. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF ALL TRADES, LANDLORD REQUIREMENTS, CEILING HEIGHTS AND EXISTING STRUCTURAL CONDITIONS PRIOR TO FABRICATION OF ANY DUCTWORK OR ORDERING OF ANY EQUIPMENT. 3. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH ALL FEDERAL, STATE AND LOCAL CODES AND ORDINANCES. 4. FURNISH ALL LABOR, MATERIALS, TOOLS, INCIDENTALS AND DETAILS NECESSARY TO PROVIDE A COMPLETE HEATING, VENTILATING, AIR CONDITIONING SYSTEM. INCLUDE ANY LABOR AND MATERIAL NOT SPECIFICALLY MENTIONED, BUT NECESSARY TO PROVIDE A COMPLETE AND OPERATING SYSTEM. ALL WORK SHALL BE INSTALLED IN A PROFESSIONAL MANNER AND SHALL MEET ALL THE REQUIREMENTS OF THE STATE BUILDING CODE, CITY BUILDING CODE, SAFETY AND HEALTH CODES, NFPA CODES AND ALL OTHER APPLICABLE CODES AND REQUIREMENTS. ALL COSTS FOR SAID REQUIREMENTS SHALL BE INCLUDED IN THIS CONTRACTORS BID PRICE. 5. THIS CONTRACTOR SHALL SECURE AND PAY FOR ALL REQUIRED PERMITS AND INSPECTIONS AND PERFORM ALL TESTS CALLED FOR OR REQUIRED AS A PART OF HIS WORK. FURNISHED APPROVED CERTIFICATE OF FINAL INSPECTION, AND TURN OVER TO OWNER AT COMPLETION OF PROJECT. 6. MECHANICAL PLANS ARE DIAGRAMMATIC, NOT SHOWING EVERY ITEM IN EXACT LOCATION OR DETAIL. MEASUREMENTS AND LOCATIONS MUST BE FIELD VERIFIED AND COORDINATED WITH ARCHITECTURAL, HVAC, FIRE PROTECTION, STRUCTURAL, ELECTRICAL AND OTHER BUILDING DRAWINGS. 7. MECHANICAL CONTRACTOR TO PROVIDE TENANT WITH AS –BUILT DRAWINGS, ALL EQUIPMENT SHOP DRAWINGS, INFORMATION ON THERMOSTATS, CONTROL WIRING DIAGRAMS AND OTHER PERTINENT INFORMATION AT COMPLETION OF PROJECT. 8. CONTRACTOR SHALL VERIFY ALL EXISTING SITE CONDITIONS PRIOR TO BID AND INCLUDE IN BID ALL COSTS TO MAKE FIELD COORDINATION AND ADJUSTMENT TO DUCTWORK FOR FIT INTO EXISTING STRUCTURE. CONTRACTOR SHALL VERIFY AND FIELD COORDINATE FINAL LOCATION OF MECHANICAL EQUIPMENT. 9. NEW DUCTS USED TO CONVEY THE CONDITIONED AIR SUPPLY AND VENTILATION AIR ARE TO BE MADE OF CONTINUOUS SHEET METAL. 10. DUCT LININGS (THERMAL AND ACOUSTICAL), VIBRATION ISOLATION CONNECTORS, FLEXIBLE DUCT CONNECTORS, AND DUCT TYPE TO BE APPROVED BY CODE AND LANDLORD. 11. ALL RECTANGULAR RETURN AIR, AND SUPPLY AIR DUCTWORK SHALL BE LINED WITH 1" THICK ACOUSTICAL LINER LINED DUCTWORK DOES NOT REQUIRE EXTERIOR INSULATION. DUCT DIMENSIONS SHOWN ARE INSIDE NET DIMENSIONS, ADD TO SHEET METAL SIZE FOR INSULATION. IN GENERAL, DUCTWORK TIGHT TO UNDERSIDE OF STRUCTURE UNLESS OTHERWISE NOTED OR REQUIRED BY FIELD CONDITIONS. COORDINATE EXACT MOUNTING HEIGHT IN FIELD WITH GENERAL CONTRACTOR. ROUND RIGID SUPPLY, RETURN, ALL RELIEF AIR AND ALL OUTSIDE AIR DUCTS SHALL BE EXTERNALLY INSULATED WITH 1" THICK, 1.5 LBS. DENSITY FOIL FACED FIBERGLASS INSULATION. ROUND DUCTWORK IN CONDITIONED SPACE DOES NOT REQUIRE INSULATION UNLESS OTHERWISE NOTED. 12. ALL DUCTWORK SHALL BE SHEET METAL FABRICATED IN ACCORDANCE WITH ASHRAE GUIDE AND SMACNA MANUAL LATEST EDITIONS. 13. ALL BRANCH TAKE –OFFS SHALL BE PROVIDED WITH MANUAL BALANCING DAMPERS. 14. FLEXIBLE INSULATED DUCTS SHALL BE MAXIMUM 5' -0" LONG AND SHALL MEET INSTALLATION AND MATERIAL REQUIREMENTS OF LOCAL CODES. 15. THE MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE TEMPERATURE CONTROL SYSTEM TO INCLUDE: PANELS, MODULES, RELAYS, WIRING, THERMOSTATS, SENSORS, DAMPERS, ACTUATORS AND ALL MISCELLANEOUS ITEMS AS REQUIRED TO FULFILL THE DESIGN INTENT AS INDICATED ON THE PLANS AND IN THE CODED NOTES. 16. ALL TEMPERATURE CONTROLS, FIRE ALARM COMPONENTS, EQUIPMENT NAMEPLATES, LABELS, OR COLOR CODED COMPONENTS SHALL BE MASKED DURING PAINTING TO PREVENT DAMAGE FROM OVER– SPRAY OR OBSCURING INFORMATION. 17. ALL LOW VOLTAGE WIRING AND CONDUIT REQUIRED FOR MECHANICAL EQUIPMENT SHALL BE FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING WITH ELECTRICAL CONTRACTOR ALL WIRING AND CONDUIT REQUIRED FOR EQUIPMENT OPERATION AND CONTROL. 18. EXISTING SPRINKLER SYSTEM TO BE MODIFIED AS REQUIRED FOR COVERAGE TO MEET LOCAL CODES AND LANDLORD REQUIREMENTS APPROVAL ALSO REQUIRED BY LANDLORD'S INSURER 19. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE THAT THE MECHANICAL EQUIPMENT COMPONENTS ARE INSTALLED AT LOCATIONS AND ELEVATIONS WHICH MAKE THEM READILY ACCESSIBLE FOR ROUTINE MAINTENANCE WITHOUT REQUIRING ANY EXTRAORDINARY MEASURES. V 0 V V MECHANICAL CODED NOTES THE MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL A PROGRAMMABLE THERMOSTAT AT 4 FT. ABOVE FINISHED FLOOR. COORDINATE EXACT LOCATION WITH TENANT. THERMOSTAT MUST BE FULLY COMPATIBLE WITH HVAC UNIT USED FOR PROJECT, COORDINATE EXACT MODEL AND TYPE WITH UNIT MANUFACTURER. THERMOSTAT TO HAVE LOCKING ACRYLIC COVER. PROVIDE NEW CONNECTION TO LANDLORD'S EXISTING MEDIUM PRESSURE DUCTWORK. VERIFY THE EXACT LOCA11ON OF THE LANDLORD'S DUCTWORK IN THE FIELD PRIOR TO BIDDING. GENERAL CONTRACTOR TO UNDER CUT DOOR, 1" FOR AIR FLOW. TOILET EXHAUST FAN COMPLETE WITH INTEGRAL BACKDRAFT DAMPER SHALL BE FURNISHED AND INSTALLED BY THE MECHANICAL CONTRACTOR. EXHAUST CAPACITY SHALL BE 100 CFM UP TO 0.625" S.P.. EXHAUST TO BE CONNECTED TO THE LANDLORD'S CENTRAL EXHAUST DUCT. REFER TO PLANS FOR FURTHER INFORMATION. FAN POWERED VARIABLE – AIR – VOLUME (VAV) PARALLEL BOX FURNISHED AND INSTALLED BY THE CONTRACTOR. UNIT I5 SUSPENDED FROM THE STRUCTURE WITH IN –UNE COMBINATION RUBBER AND SPRING VIBRATION ISOLATORS FURNISHED AND INSTALLED BY THE GENERAL CONTRACTOR. EXISTING DUCTWORK TO REMAIN. TYPE, SIZE AND ELEVATION ARE AS NOTED. TENANT SHALL FURNISH /MAINTAIN A 6" MINIMUM CLEAR OPEN HEIGHT ABOVE COMMON TENANT DEMISING WALLS AND BELOW STRUCTURE, OR OTHER BUILDING ELEMENTS (DUCTS, FOR EXAMPLE) THAT WOULD ALLOW THE PASSAGE OF RETURN AIR BACK TO THE LANDLORD'S HVAC UNIT. REFER TO THE LANDLORD'S DETAIL FOR FURTHER INSTRUCTIONS. SMOKE DETECTOR FURNISHED BY ELECTRICAL CONTRACTOR AND INSTALLED BY MECHANICAL CONTRACTOR. SMOKE DETECTOR MUST BE IN AN ACCESSIBLE LOCA11ON IN AIR DUCT. THE ELECTRICAL CONTRACTOR TO WIRE THE SHUT DOWN SEQUENCE OF THE HVAC UNIT UPON SENSING SMOKE, AND TO INTERFACE WITH THE MALL'S FIRE /SMOKE ALARM SYSTEM. REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION. 20" X 20" CEILJNG ACCESS PANEL BY GENERAL CONTRACTOR. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN AND ARCHITECTURAL SPECIFICATIONS FOR FURTHER INFORMATION. ACCESS PANEL TO BE USED FOR ACCESS TO EQUIPMENT LOCATED ABOVE THE CEILING. THIS CONTRACTOR SHALL BE RESPONSIBLE TO ENSURE THAT A MINIMUM UNOBSTRUCTED FREE AREA OF 3 –FEET VERTICALLY AND 2 –FEET HORIZONTALLY IN ALL DIRECTIONS AROUND EQUIPMENT IS MAINTAINED TO ALLOW FOR INSTALLATION AND MAINTENANCE OF EQUIPMENT. VERIFY ALL CONDITIONS IN THE FIELD PRIOR TO BIDDING L.L.'S EXIST. TOILET EXHAUST DUCT L.L.'S EXIST. SUPPLY AIR DUCT ' • \ 1 MECHANICAL PLAN 1 /4 " =1' -O" �11 rhPir" +LViSr+; r* s i:k'''1t1n r2t tr,4HF., N1CTE. Rev sions and may ���,�� ^� ; ,� r,. ^,. rr, FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AF IhR BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. REV&WtD k CODE COMPLIANCE APPROVED JUL 01 2008 C € rit �o tvK Pi sr- rDV W approval is su *p t tO C., , ,. c m :_,. ;. Approva+ of construction docufinem "s do;_, nct aulorial the vitiation of any adopted co& or orelnanm. P,7. - 7 { approved Field py and co Mons' ..:cis ovt..77.w :' By Date: ,,� 3 B- ��L DINS Da ,'MON PERMIT REQUIRED FOR: Mechanical J Electrical 12 g Gas Piping City Of Tukwila Mill DING DIVISION Ho8 13'1 REVISION NO*L RECEIVED JUN 2 42008 Emphceie On Excellence M • Retail Engineering, inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 PHONE 614.818.2323 FAX 614.818.2337 WEB www.m— corporations.com PERMIT CENTER P%Ject Design 4 Drawings Q 2001 Amen Architecre Original Prototre Design 0 200b Jel cen Architecture DstAr186 HC HLTAL DIESOO l 2850 I i©LHD AVENUE NU CLEVELAND, LAND, 0 00 (MS PHONE 211©o781d011M Fag 29©J81100184 JUN 1 9 2333 amis go, 0 " CD CO t CD a a) Q C!) o mo . co E a) 0) 5 I GRCEMOSSOO IS M1 no1otn1raetawaw 1C COQbO ©ad PLAN DATE: 5/20/08 RICHARD R. JENCEN ASSOCIATES MECHANICAL /PLUMBING RESPONSIBILITY SCHEDULE ITEM FURNISHED BY INSTALLED BY REUSE EXISTING N/A REMARKS TENANT LANDLORD CONTR. LANDLORD CONTR. AIR HANDLING UNITS CLG. OTHER STEEL ALUM. SD -1 T1TUS OMNI 0 10 "0 STRUCTURAL SUPPORTS FOR AHU AS REQUIRED VAV -1 0 3 A 810 B 33 SD -2 AHU MIXING BOX AND MIXING BOX MOTOR OPERATED DAMPERS 24 "x24" 10 "0 0 - 0 - 0 AHU MIXING BOX MOTOR OPERATED DAMPER ACTUATOR • CONDENSING UNITS RG -1 TITUS 355RL 0 22 "x22" CURB AND /OR STRUCTURAL SUPPORTS FOR COND. UNITS AS REQUIRED 0 A B 0 RG -2 ROOF TOP UNITS 24 "x12" 22 "x10" 0 0 0 ROOF CURB AND /OR CURB ADAPTER FOR RTU AS REQUIRED • STRUCTURAL SUPPORTS FOR RTU AS REQUIRED. V.A.V. BOXES 0 0 SEE CODED NOTES DIFFUSERS AND GRILLES 0 0 DIFFUSERS /GRILLES ARE DAMPERS 0 WALL FIRE DAMPERS AND /OR COMBINATION SMOKE /FIRE DAMPERS 0 LOW PRESSURE DUCTWORK 0 0 HIGH /MEDIUM PRESSURE DUCTWORK 0 0 SEE CODED NOTES TEMPERATURE CONTROL SYSTEM 0 0 SEE CODED NOTES RELIEF AIR /MAKE UP AIR MOTOR OPERATED DAMPERS RELIEF AIR /MAKE UP AIR MOTOR OPERATED DAMPER ACUATORS SMOKE DETECTOR(S) IN RETURN AND /OR SUPPLY AIR DUCT 0 SEE CODED NOTES ZONE DAMPERS 0 DUCT HEATER(S) 0 UNIT /BASEBOARD HEATER(S) 0 RETURN AIR FAN 0 OUTSIDE AIR INTAKE HOOD /FAN 0 RELIEF AIR FAN OR HOOD 0 TOILET EXHAUST FAN(S) 0 0 SEE CODED NOTES TOILET EXHAUST DUCTWORK WALL OR ROOF CAP 0 0 SEE CODED NOTES AIR BALANCE REPORT 0 AABC OR NEBB CERTIFIED AS -BUILT DRAWINGS 0 PLUMBING FIXTURES 0 0 SAN, CW, HW, PIPING AND WATER METER 0 0 SPRINKLER PIPING AND HEADS 0 CO REWORK PIPING IF POSSIBLE FIRE EXTINGUISHERS 0 0 BY G.C. IF NONE EXISTING GENERAL NOTE A "QUICK" REFERENCE. ALL ITEMS LISTED HERE ARE SPECIFIED AND DETAILED ENCOUNTERS ITEMS THAT ARE CONTRADICTORY THEN IT IS HIS CONSTRUCTION MANAGER SO THAT THESE ITEMS CAN BE CLARIFIED THIS SCHEDULE IS INTENDED AS ON THESE DRAWINGS. IF THE CONTRACTOR RESPONSIBILITY TO INFORM TENANTS FOR THE CONTRACTOR. AIR DEVICE SCHEDULE NOTES : 1. SYMBOL KEY - 4. VOLUME DAMPER - FIRST LETTER: S- SUPPLY R- RETURN E -EXH T- TRANSFER FACTORY FURNISHED. OPPOSED BLADE OR BUTTERFLY SECOND LETTER: D- DIFFUSER R- REGISTER G- GRILLE WHERE AVAILABLE. ADJUSTABLE FROM FACE. 2.PROVIDE OPI1OAL DIRECTIONAL BLOW FEATURE FOR 5. BORDER STYLE - OTHER THAN 4 -WAY. " A" SURFACE MOUNTED 3. FINISH- " B " LAY -IN, PROVIDE WITH PLASTER FRAME " WHITE. FOR DRYWALL CEILING MOUNTING. "B" WHITE - G.C. TO FIELD PAINT "C" LAY -IN FRAME FOR T -BAR CEILING. TO MATCH CEILING OR WALL WITH ENAMEL FINISH. 6. PROVIDE BOOT FOR DUCT MOUNTING. SYMBOL (1)(2) MANUFACTURER,' CATALOG NUMBER NOMINAL SIZE MOUNTING MATERIAL FINISH (3) DPR. (4) BORDER (5) REMARKS MOD. NECK CLG. OTHER STEEL ALUM. SD -1 T1TUS OMNI 24 "x24" 10 "0 0 VAV -1 0 3 A 810 B 33 SD -2 TITUS TMS 24 "x24" 10 "0 0 - 0 - A C RG -1 TITUS 355RL 24 "x24" 22 "x22" 0 0 A B RG -2 TITUS 355RL 24 "x12" 22 "x10" 0 0 A C • VAV BOX SCHEDULE TAG MODEL BOX SIZE PRIMARY AIR INLET SIZE ("0) BOX PRIMARY CFM RADIATED MAXIMUM NC FAN (PARALLEL) ELECTRIC HEATING COIL REMARKS DESIGN OPERATION CFM E.S.P. (IN WC) HP VOLTS PHASE KW STEPS EAT (. LAT (IF) VOLTS PHASE DESIGN COOLING DESIGN HEATING VAV -1 45M 3 8 "0 810 - 33 810 1 1/10 208 3 - - - - :„..... Design Parameters: City Name Seattle IAP Location Washington Latitude 47.5 Deg. Longitude 122.3 Deg. Elevation 449.0 ft Summer Design Dry-Bulb 85.0 ° F Summer Coincident Wet -Bulb 65.0 °F Summer Daily Range 18.3 °F Winter Design Dry 23.0 °F Winter Design Wet - Bulb 19.2 ° F Atmospheric Clearness Number 1.05 Average Ground Reflectance 0.20 Soil Conductivity .... 0.800 BTU /(hr- ft - ° F) Local Time Zone (GMT N hours) 8.0 hours Consider Daylight Savings Time Yes Daylight Savings Begins April,1 Daylight Savings Ends October, 31 Simulation Weather Data noneN /A Current Data is 2001 ASHRAE Handbook Design Cooling Months January to December Air System Information Air System Name SALES/NON-SALES Equipment Class PKG ROOF Air System Type VAV Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible Toad Space CFM Individual peak space Toads Central Cooling Coil Sizing Data Total coil load 1.3 Tans Total coil load 15.6 MBH Sensible coil load 13.1 MBH Coil CFM at Jan 2100 658 CFM Max block CFM at Jan 2100 .. 801 CFM Sum of peak zone CFM 801 CFM Sensible heat ratio 0.841 ft 693.9 BTU /(hr -ft 17.3 Water flow @ 10.0 °F rise N/A Preheat Coil Sizing Data No heating coil loads occtrred during this calculation. Supply Fan Sizing Data Actual max CFM at Jan 2100 801 CFM Standard CFM 788 CFM Actual max CFM/ft 0.89 CFM/ft Outdoor Ventilation Air Data Design airflow CFM 0 CFM CFMff1 0.00 CFM/ft Number of zones 2 Floor Area 900.0 ft Location .. Seattle IAP, Washington Calculation Months Jan to Dec Sizing Data Calculated Load occurs at Jan 2100 OA DB / WB 58.2 / 50.4 °F Entering DB / WB 76.7 / 64.8 °F Leaving DB /WB 58.0 156.9 °F Coil ADP 55.9 °F Bypass Factor 0.100 Resulting RH 56 % Design supply temp. 58.0 °F Zone T -stat Check 2 of 2 OK Max zone temperature deviation 0.0 °F Fan motor BHP 0.00 BHP Fan motor kW 0.00 kW Fan static . 0.00 in wg CFM /person 0.00 CFM /person Air System Information Air System Name SALES/NON-SALES Equipment Class PKG ROOF Air System Type VAV Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible Toad Space CFM Individual peak space Toads Zone Sizing Data Zone Name Zone 1 Zone 2 Space Loads and Airflows Zone Name / Space Name Zone 1 SALES Zone 2 NON -SALES Maximum Cooling Sensible (MBH) 8.5 4.1 Mult. 1 1 Cooling Sensible (MBH) Design Air Flow (CFM) 573 228 Number of zones 2 Floor Area 900.0 ft Location Seattle IAP, Washington Calculation Months Jan to Dec Sizing Data Calculated Minimum Air Flow (CFM) 6 2 Time of Load Air Flow (CFM) 8.5 Jan 2100 573 4.1 Jan 2100 228 Time of Peak Load Jan 2100 Jan 2100 Heating Load (MBH) 0.0 0.0 Maximum Heating Load (MBH) 0.0 0.0 Zone Floor Area (ft 740.0 160.0 Floor Area Space (ft CFMiftt 740.0 160.0 0.77 1.42 Zone CFM/ft 0.77 1.42 DESIGN COOLING COOLING DATA AT Jan 2100 COOLING OA DB 1 WB 58.2 °F / 50.4 °F ZONE LOADS Details Window & Skylight Sola r Loads 0 ft Wall Transmission 0 ft Roof Transmission 0 ft Window Transmission 0 ft Skylight Transmission Door Loads 0 ft Floor Transmission 900 ft Partitions 0 ft Ceiling 0 ft Overhead Lighting 996 W Task Lighting 784 W Electric Equipment 1596 W People 11 Infiltration - Miscellaneous - Safety Factor 5% / 5% » Total Zone Loads - Zone Conditioning - Plenum Wall Load 0% Plenum Roof Load 70% Plenum Lighting Load 30% Return Fan Load 658 CFM Ventilation Load 0 CFM Supply Fan Load 658 CFM Space Fan Coil Fans Duct Heat Gain / Loss >a Total System Loads Central Cooling Coil Preheat Coil Terminal Reheat Coils » Total Conditioning Key: Positive values are clg loads Negative values are htg Toads 0 ft2 0% Sensible ( BTU/hr) 0 0 0 0 0 0 0 0 0 2160 2359 5159 2365 0 0 602 12645 12075 0 0 1020 0 0 0 0 0 13094 13094 0 0 13094 DESIGN HEATING HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F 1 19.2 °F Sensible (BTU/hr) Latent ( BTUIhr) Details 0 11 - 0 11 0 - 0 11 0 0ft 0 O ft 0 0ftx 0 900 ft 0 0 ft 2 0 0ft 0 0 0 0 0 - 0 0 2351 0 0 0 - 0 0 - 0 118 5% 0 2468 - 0 2468 - -96 0 0 0 0 0 0 8 CFM 0 0 O CFM 0 8 CFM 0 0 0% 0 2468 - - 96 2471 - -96 - - 0 0 2471 - 96 Positive values are htg loads Negative values are clg loads Latent ( BTU/hr) 0 0 0 0 0 0 0 0 0 0 ALL DUCT LINER TRANSVERSE EDGES TO BE COATED W/ ADHESIVE IN ACCORDANCE W/ SMACNA STANDARDS (TYP.) TAPE DOWN EXTERNAL INSULATION FASTEN W/ MIN. (3) SHT. MTL. SCREWS, SEAL W/ DUCT TAPE AND MASTIC ROUND RIGID DUCT - 1" WRAPPED INSULATION NOTES: L MAIN DUCT VAV BOX (SINGLE OR DUAL DUCT). SEE PLANS AND SCHEDULE FOR TYPES & SIZES. TRANSITION (AS REQUIRED) MEDIUM PRESSURE FLEXIBLE PRIMARY AIR INLET (MAXIMUM 5' -0" LENGTH). PRIMARY AIR INLET FLANGED AND GASKETED JOINT OR DUCT CONNECTION AND RE- INFORCEMENT IN ACCORDANCE W/ SMACNA 2" W.G. CLASS, SEAL NON - GASKETED TRANS- VERSE JOINTS IN ACCORDANCE W/ SMACNA CLASS "C" (TYP.) 1" ACOUSTICAL LINING �- AIR FLOW CONICAL OR BELLMOUTH SPIN - IN FITTING, SEAL AIRTIGHT W/ MASTIC TYP. ROUND DUCT TAKE -OFF SCHEMATIC N TS A MINIMUM STATIC PRESSURE DROP ACROSS THE VAV BOX FOR PROPER OPERATION SHALL BE BETWEEN 0.1" AND 0.15 ", AS TESTED PER ARI 880. BOX SUPPORT PER SPECIFICATIONS & MANUFACTURER'S RECOMMENDATIONS. SUPPORTS SHALL NOT INTERFERE WITH ACCESS PANELS. TRANSITION (AS REQUIRED) FLEXIBLE CONNECTION NIT OUTLET MAINTAIN 18" CLEARANCE FOR CONTROL ACCESS. VERIFY CONTROLS LOCATION WITH MANUFACTURER. TO S.A. MAIN _- INSULATED ROUND DUCT VOLUME DAMPER VAV BOX SCHEMATIC N TS NOTE: CLOSELY COORDINATE LOCATIONS OF ALL BOXES WITH STRUCTURE, CEILINGS, LIGHTS, PIPING, AND CONDUITS. PROVIDE FULL ACCESSIBIUTY TO UNIT AND CONTROLS. SUPPLY AIR DIFFUSER FLEXIBLE CONNECTION (MAX. 5 FT.) THERMAL INSULATING BLANKET WHERE REQUIRED. I I I I I I I SIZED PER PLANS RECTANGULAR LINED DISCHARGE DUCT SAME SIZE AS COIL OUTLET. (MINIMUM 5-0" LENGTH) STRAP CLAMP (TYPICAL) FIRE DAMPER WHERE REQUIRED DRYWALL CEILING PLASTER FRAME DIFFUSER MOUNTING SCHEMATIC N TS REVIEWED FOR CODE COMPLIANCE APPROVED JUL 0 2008 City Of Tukwila B ILDIN DIVI ION AA01 Empmai. on Exedlmc. M- Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 PHONE 614.818.2323 FAX 614.818.2337 WEB www.m-- corporations.com RECEIVED JUN 242008 PERMIT CENTER ProJee Design 4 Drawings ® 2001 Amin Archltactire Original Prete:Vs Design ® 2006 Jencan ArdlnA care PRAFTERt K_101,1K1 IRCHTECTURE NET1 DL IYESllieki 2830 I M©LODD AVE RUE CLEVELAND, NM 64115 P11 ©l1VEc C�151. ��99V0 01l Z1 FQ {a 216.783to 1 JUN 1 9 2C 1 6 1mi g g e i iA � L J a ) Q 5E OD s O I 0 ma IREVOSOOKIS M2 na+onni ow* co co r co 0) A. GENERAL CONDITIONS 1. DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND ALL OTHER SPECIFICATION SECTIONS ARE A PART OF THIS CONTRACT AND APPLY TO THIS AND THE OTHER SECTIONS OF DIVISION 15. 2. THE CONTRACTOR FOR THIS WORK IS REQUIRED TO READ THE ENTIRE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL OTHER TRADES. 3. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING HIS SUBCONTRACTORS WITH A FULL SET OF BID SET DOCUMENTS (INCLUDING SPECIFICATIONS) AND THE COORDINATION OF HIS WORK AND INSPECTIONS AND THE WORK AND INSPECTIONS OF HIS SUBCONTRACTORS WITH ALL OTHER TRADES ON SITE CONFORMING TO THE GENERAL CONTRACTOR'S TIME SCHEDULE. 4. THE CONTRACTOR SHALL VISiT THE SITE PRIOR TO SUBMITTING HIS BID TO DETERMINE CONDITIONS AFFECTING THE WORK. BIDS SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS AND ANY MODIFICATIONS WHICH ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS. FAILURE TO VISIT THE SITE DOES NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY IN PERFORMANCE OF WORK. 5. WHEN USED, THE TERM 'PROVIDED BY CONTRACTOR' SHALL BE INTERPRETED AS MEANING 'FURNISHED AND INSTALLED' WITH THE EXCEPTION WHERE ITEMS ARE 'PROVIDED BY TENANT' WHICH MEANS "FURNISHED ONLY' (INSTALLED BY CONTRACTOR), EXCEPT AS SPECIFICALLY NOTED OTHERWISE. B. GENERAL REQUIREMENTS 1. THE CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION, INCIDENTALS AND DETAILS NECESSARY TO PROVIDE A COMPLETE AND FULLY FUNCTIONAL MECHANICAL SYSTEM AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR. CLOSELY COORDINATE THE ENTIRE INSTALLATION WITH THE LANDLORD, AS REQUIRED. FIELD VERIFY THE EXACT TYPE, SIZE AND LOCATION. ETC. OF EXISTING PIPE AND DUCTS IN THE TENANT SPACE PRIOR TO BID. 2. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY MATERIAL OR LABOR CALLED FOR IN ONE SHALL BE PROVIDED EVEN THOUGH NOT SPECIFICALLY MENTIONED IN BOTH. ANY MATERIAL OR LABOR WHICH 15 NEITHER SHOWN ON THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS, BUT WHICH IS OBVIOUSLY NECESSARY TO COMPLETE THE WORK, AND WHICH IS USUALLY INCLUDED IN WORK OF SIMILAR CHARACTER, SHALL BE PROVIDED AS PART OF CONTRACT. 4. ALL MECHANICAL WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING, AND REPAIRING. THE CONTRACTOR I5 RESPONSIBLE FOR PROVIDING SUFFICIENT ACCESS TO ALL EQUIPMENT FOR SERVICE. D. LICENSES, PERMITS, INSPECTIONS & FEES 1. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LICENSES, PERMITS. AND OR RELATED TO HIS FEES REQUIRED H S WORK. QU 2. FURNISH TO THE TENANT'S CONSTRUCTION MANAGER ALL CERTIFICATES OF INSPECTION AND FINAL INSPECTION APPROVAL AT SIESTANTIAL COMPLETION DATE OF PROJECT. E. DRAWINGS 1. DRAWINGS (PLANS, SPECIFICATIONS, AND DETAILS) ARE DIAGRAMMATIC AND INDICATE THE GENERAL LOCATION AND INTENT OF THE MECHANICAL SYSTEMS. THE DRAWINGS, NOT POSSIBLE OF THE SMALL SCALE OF RA INGS, IT IS P055 E O T INDICATE ALL DUCT AND PIPING OFFSETS, FITTINGS AND ACCESSORIES THAT MAY BE REQUIRED. 2. THE LAYOUT SHOWN ON THE DRAWINGS I5 BASED ON A PARTICULAR MAKE OF EQUIPMENT. IF ANOTHER MAKE OF EQUIPMENT I5 USED WHICH REQUIRES MODIFICATION OR CHANGE OF ANY DESCRIPTION FROM THE DRAWINGS OR SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE AS PART OF THIS WORK, FOR MAKING ALL SUCH MODIFICATIONS AND CHANGES, INCLUDING THOSE INVOLVING OTHER TRADES WITH THE COST THEREOF INCLUDED IN HIS BID. IN SUCH CASE, CONTRACTOR SHALL SUBMIT DRAWINGS AND SPECIFICATIONS PRIOR TO STARTING WORK SHOWING ALL SUCH MODIFICATIONS AND CHANGES. HIS PROPOSAL SHALL BE SUBJECT TO THE APPROVAL OF THE TENANT'S CONSTRUCTION MANAGER. F. EXISTING SHELL SPACE CONDITONS 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF THE DEMOLITION OF EXISTING MECHANCIAL WORK SHOWN CN THE MECHANCIAL DRAWINGS AND THE MECHANCIAL DEMOLITION SHOWN ON THE ARCHITECTURAL DRAWINGS. 2. THE CONTRACTOR SHALL INCLUDE. AND WILL BE HELD RESPONSIBLE FOR, THE REMOVAL OF ALL EXISTING FIRE PROTECTION, PLUMBING FIXTURES, PIPING, HVAC UNITS, REFRIGERANT RECAPTURE, EXHAUST FANS, ETC. AND ASSOCIATED ROOF CURBS NOT TO BE REUSED ON THIS PROJECT, UNLESS SPECIFICALLY NOTED OTHERWISE. CONTRACTOR MUST VERIFY WITH THE LANDLORD ALL PRESUMED ABANDONED EQUIPMENT, PIPES, DUCTWORK, AND EQUIPMENT PRIOR TO REMOVAL. ROOF CURBS SHALL BE REMOVED AND THE ROOF PATCHED UNLESS NOTED FOR REUSE OR RECONFIGURATION ON PLANS. ROOF PATCHING SHALL BE PERFORMED AT THE CONTRACTOR'S EXPENSE BY A ROOFING CONTRACTOR APPROVED BY THE LANDLORD. ALL EXTRANEOUS ITEMS IN THE SPACE OR ON THE ROOF (ABOVE THIS SPACE) NOT APPLICABLE TO THE NEW WORK OR PART OF THE LANDLORD'S OR ANOTHER TENANT'S ACTIVE SYSTEM MUST BE REMOVED AND ROOF/WALL /FLOOR PATCHED/REPAIRED TO MATCH EXISTING STRUCTURE. EXISTING ABANDONED PIPES, DUCTS, OR EQUIPMENT IN THE FLOOR, EMBEDDED IN CONCRETE, OR OTHERWISE INACCESSIBLE ARE TO BE CUT OFF AND SEALED BELOW OR WITHIN FLOOR OR WALL LEVEL WHEN THEY ARE NOT TO BE REUSED IN THIS PROJECT. IF REQUIRED BY LANDLORD OR CODES. ABANDONED PIPING AND /OR DUCTWORK MUST BE REMOVED TO POINT OF ORIGIN. CONFIRM THE EXTENT OF DEMOLITION PRIOR TO BID AND INCLUDE IN BID PROPOSAL. G. DISCREPANCIES IN DOCUMENTS 1. DRAWINGS (PLANS, SPECIFICATIONS, AND DETAILS) ARE DIAGRAMMATIC AND INDICATE THE GENERAL LOCATION AND INTENT OF THE MECHANICAL SYSTEMS. WHERE DRAWINGS, EXISTING SITE CONDITIONS, SPECIFICATIONS OR OTHER TRADES CONFLICT OR ARE UNCLEAR. ADVISE THE GENERAL CONTRACTOR IN WRITING, PRIOR TO SUBMITTAL OF BiD. THE GENERAL CONTRACTOR IS RESPONSIBLE TO ADVISE THE TENANT'S CONSTRUCTION MANAGER. IN WRITING, OF VARIATIONS TO CONTRACT DOCUMENTS PRIOR TO SUBMISSION OF BID. OTHERWISE, TENANT'S CONSTRUCTION MANAGER'S INTERPRETATION OF CONTRACT DOCUMENTS OR CONDITIONS SHALL BE FINAL WITH NO ADDITIONAL COMPENSATION PERMITTED. H. TRADE NAMES AMID MANUFACTURERS DIVISION 15 - IECHWIICAI. SECTION 15000 MECHANICAL GENERAL. PROVISIONS 1. WHERE TRADE NAMES AND MANUFACTURERS ARE USED ON THE DRAWINGS DR iN THE SPECIFICATIONS, THE EXACT EQUIPMENT SHALL BE USED AS A MINIMUM STANDARD FOR THE BASE BID. MANUFACTURERS CONSIDERED AS AN EQUAL OR BETTER IN ALL ASPECTS TO THAT SPECIFIED WILL BE SUBJECT TO APPROVAL IN WRITING BY THE TENANT'S CONSTRUCTION MANAGER PRIOR TO ACCEPTANCE. THE USE OF ANY UNAUTHORIZED EQUIPMENT SHALL BE SUBJECT TO REMOVAL AND REPLACEMENT AT THE CONTRACTOR'S EXPENSE. J. K. 3. WHERE THE DRAWINGS OR SPECIFICATIONS CALL FOR ITEMS WHICH EXCEED CODES OR THE LANDLORD'S TENANT CRITERIA, THE CONTRACTOR IS STILL RESPONSIBLE 1. FOR PROVIDING THE SYSTEM AS DESIGNED AND DESCRIBED ON THESE DRAWINGS, UNLESS SPECIFICALLY NOTED OTHERWISE. 5. THE CONTRACTOR SHALL DO ALL CUTTING, CORE DRILLING, CHASING OR CHANNELING AND PATCHING REQUIRED FOR ANY WORK UNDER THIS DIVISION. L. CUTTING SHALL HAVE PRIOR APPROVAL BY THE TENANT'S CONSTRUCTION MANAGER AND THE LANDLORD. PATCHING SHALL MATCH, FINISH OF SURROUNDING AREA. C. CODES 1. ALL WORK SHALL BE PERFORMED IN A NEAT PROFESSIONAL MANNER USING GOOD ENGINEERING PRACTICES. ALL WORK SHALL CONFORM TO THE LANDLORD'S CRITERIA, THE STATE'S, COUNTY'S, CITY'S AND LOCAL CODES AND ORDINANCES, SAFETY AND HEALTH CODES, NFPA CODES, ENERGY CODES AND ALL OTHER APPLICABLE CODES AND REQUIREMENTS. THE CONTRACTOR SHALL INQUIRE M. INTO AND COMPLY WITH ALL APPLICABLE CODES, ORDINANCES, AND REGULATIONS. AFTER CONTRACT IS ISSUED, ND ADDITIONAL COST DUE TO CODE ISSUES SHALL BE REIMBURSED BY THE TENANT TO THE CONTRACTOR. 3. ACTIVE LANDLORD OR OTHER TENANT SERVICES ENCOUNTERED IN WORK SHALL BE PROTECTED AND SUPPORTED. IF EXISTING SERVICES NOT ANTICIPATED REQUIRE RELOCATION, CONTACT THE TENANT'S CONSTRUCTION MANAGER IMMEDIATELY. P. ALL COSTS FOR REPAIR OF DAMAGES TO ACTIVE LANDLORD OR OTHER TENANT SERVICES DURING CONSTRUCTION SHALL BE PAID FOR BY THE CONTRACTOR CAUSING THE DAMAGE. 4. TIE -INS AND MODIFICATIONS TO EXISTING LANDLORD SERVICES MUST BE DONE WITH MINIMUM INTERRUPTION OF LANDLORD OPERATION AND DURING HOURS SPECIFIED BY THE LANDLORD. THE CONTRACTOR 15 RESPONSIBLE FOR CONFIRMING EXACT WORKING HOURS OF THIS WORK WITH THE LANDLORD PRIOR TO SUBMITTING HIS BID. THE CONTRACTOR SHALL INCLUDE IN HIS BID, ALL PREMIUM TIME REQUIRED TO PERFORM MODIFICATIONS DURING OTHER THAN NORMAL WORKING HOURS. ALL SUCH WORK MUST BE COORDINATED WITH THE LANDLORD. Q. SHOP DRAWINGS A. SCOPE CF YORK 1. SUBMIT SIX COPIES OF MATERIAL LISTS AND SHOP DRAWINGS FOR ALL EQUIPMENT AND DUCT FABRICATION DRAWINGS TO THE TENANT'S CONSTRUCTION MANAGER FOR APPROVAL PRIOR TO ORDERING EQUIPMENT. SUBMISSIONS MUST BE EARLY ENOUGH TO ALLOW TIE TENANT'S CONSTRUCTION MANAGER EIGHT WORKING DAYS FOR REVIEW WITHOUT CAUSING DELAYS OR CONFLICTS TO THE JOB'S PROGRESS. SUBMITTALS SHALL BE IN ACCORDANCE WITH THE GENERAL CONDITIONS USING THE MANUFACTURER'S LISTED ON THE DRAWINGS. SHOP DRAWINGS SMALL INCLUDE ALL DATA THAT PERTAINS TO THE REQUIREMENTS SET FORTH ON THE DRAWINGS AND IN THE SPECIFICATIONS. THE SUBMITTAL SHALL INCLUDE BUT NOT LIMITED TO CUTS OR CATALOGS INCLUDING DESCRIPTIVE LITERATURE AND CHARACTERISTICS OF EQUIPMENT SHALL SHOW MAJOR DIMENSIONS, ROUGHING -IN DATA, CAPACITY, CURVES, PRESSURE DROP, CODE COMPLIANCE, MOTOR AND DRIVE DATA AND ELECTRICAL DATA. OBSERVE SPECIAL INSTRUCTIONS WHEN REQUIRED. SUBMITTALS SHALL BEAR THE STAMP OF THE GENERAL AND SUB - CONTRACTOR SHOWING THAT HE HAS REVIEWED AND CONFIRMED THAT THEY ARE IN CONFORMANCE WITH THE CONTRACT DRAWINGS AND SPECIFICATIONS OR INDICATE WHERE EXCEPTIONS TAKE PLACE. LACK OF SUCH CONTRACTOR'S REVIEW AND APPROVAL WILL BE CAUSE FOR REJECTION WITHOUT REVIEW BY TENANT'S CONSTRUCTION MANAGER. ALL SHOP DRAWINGS MUST APPEAR IN THE OPERATION AND MAINTENANCE MANUALS LEFT ON SITE AT JOB COMPLETION. 2. TENANT'S CONSTRUCTION MANAGER'S REVIEW OF SHOP DRAWINGS OR SCHEDULES SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR ERRORS, OMISSIONS OR OTHER DEFICIENCIES OR DEVIATIONS IN THE SHOP DRAWING FROM THE CONTRACT DRAWINGS AND SPECIFICATIONS. RECORD DRAWINGS THE CONTRACTOR SHALL MAINTAIN ONE COPY OF DRAWINGS AND SPECIFICATIONS ON THE JOB SITE TO RECORD DEVIATIONS FROM CONTRACT DRAWINGS, SUCH AS: A. LOCATION OF CONCEALED PIPING VALVES AND DUCTS. B. REVISIONS, ADDENDUMS, AND CHANGE ORDERS. C. SIGNIFICANT DEVIATIONS MADE NECESSARY BY FIELD CONDITIONS, APPROVED EQUIPMENT SUBSTITUTIONS, AND CONTRACTOR'S COORDINATION WITH OTHER TRADES. D. EXACT ROUTING OF ALL SANITARY AND DOMESTIC WATER PIPING UNDER FLOOR. 2. AT COMPLETION OF THE PROJECT AND BEFORE FINAL APPROVAL, THE CONTRACTOR SHALL MAKE ANY FINAL CORRECTIONS TO DRAWINGS AND CERTIFY THE ACCURACY OF EACH PRINT BY SIGNATURE THEREON. THE DRAWINGS ARE TO BE TURNED OVER TO THE TENANT. GUARANTEE THE CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORK UNDER HIS CONTRACT AND SHALL MAKE GOOD, REPAIR OR REPLACE AT HIS OWN EXPENSE. ANY DEFECTIVE WORK, MATERIAL. CR EQUIPMENT WHICH MAY BE DISCOVERED WITHIN A PERIOD OF 12 MONTHS FROM THE DATE OF ACCEPTANCE (IN WRITING) D. OF THE INSTALLATION BY THE TENANT'S CONSTRUCTION MANAGER. PROVIDE EXTENDED WARRANTIES AS SPECIFIED WITH INDIVIDUAL EQUIPMENT. IN CASE OF REPLACEMENT OR REPAIR OR EQUIPMENT DUE TO FAILURE WITHIN GUARANTEE PERIOD, GUARANTEE ON THAT PORTION OF WORK SHALL BE EXTENDED FOR A PERIOD OF ONE (1) YEAR FROM DATE OF SUCH REPLACEMETN OR REPAIR. OPERATIONS MANUALS 1. SLEEVES ONE COPY OF EACH OPERATION AND MAINTENANCE MANUAL FOR ALL EQUIPMENT FURNISHED ON JOB SHALL BE COLLECTED AND INSERTED IN A 3' THREE RING R AND TO THE TENANT. NOTEBOOK SHALL TURNED OVER T EACH L IN CLUDE BUT NOT BE LIMITED TO INSTALLATION, MAINTENANCE AND OPERATING INSTRUCTIONS, PAMPHLETS OR BROCHURES APPROVED SHOP DRAWINGS AND WARRANTIES OBTAINED FROM EACH MANUFACTURER OF PRINCIPAL ITEMS OF EQUIPMENT. THE CONTRACTOR SHALL PROVIDE SLEEVES TO PROTECT EQUIPMENT OR FACILITIES IN THE INSTALLATION. EACH SLEEVE SHALL EXTEND THOROUGH iT'S RESPECTIVE FLOOR, WALL OR PARTITION AND SHALL BE CUT FLUSH WITH EACH SURFACE EXCEPT SLEEVES THAT PENETRATE THE FLOOR, WHICH SHALL EXTEND 2' ABOVE THE FLOOR. 2. ALL SLEEVES AND OPENINGS THROUGH FIRE RATED WALLS AND /OR FLOORS SHALL BE FIRE SEALED WITH CALCIUM SILICATE, SILICONE 'RN" FOAM, '3M" FIRE RATED SEALANTS OR EQUAL, 5O AS TO RETAIN THE FIRE RATING OF THE FLOOR OR WALL. CONFORM TO U.L. ASSEMBLY RATING OF FLOOR OR WALL. 3. SLEEVES IN BEARING AND MASONRY WALLS, FLOORS, AND PARTITIONS SHALL BE STANDARD WEIGHT STEEL PIPE FINISHED WITH SMOOTH EDGES. FOR OTHER THAN MASONRY PARTITIONS, THROUGH SUSPENDED CEILINGS, OR FOR CONCEALED G NO. 22 U.S.G. VERTICAL PIPING, SLEEVES SHALL BE GAL VANIZED STEEL MINIMUM. 1. 4. DUCT SLEEVES TO BE MINIMUM 14 GAUGE STEEL. N. HANGERS HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS ANGLE IRON, BANDS, CLAPS WITH RETAINING CLIPS. CHANNELS, HANGER RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK. 2. HANGERS SHALL BE FASTENED TO BUILDING STEEL, CONCRETE, OR MASONRY, BUT NOT TO PIPING OR DUCTWORK. HANGING FROM METAL DECK IS NOT PERMITTED. HANGERS MUST BE ATTACHED TO UPPER CHORD OF BAR JOIST. WHERE INTERFERENCES OCCUR, IN ORDER TO SUPPORT DUCTWORK OR PIPING, THE CONTRACTOR MUST INSTALL TRAPEZE TYPE HANGERS OR SUPPORTS WHICH SHALL BE LOCATED WHERE THEY DO NOT INTERFERE WITH ACCESS TO FIRE DAMPERS, VALVES, ACCESS DOORS AND OTHER EQUIPMENT SERVICE REQUIREMENTS AND /OR OTHER TRADES. HANGER TYPES AND INSTALLATION METHODS ARE SUBJECT TO LANDLORD CRITERIA. 3. HANGERS FOR ALL INSULATED PIPING SHALL BE SIZED AND INSTALLED FOR THE OUTER DIAMETER OF INSULATION. INSTALL 6' LONG SPLIT CIRCLE GALVANIZED SADDLE BETWEEN THE HANGER AND THE PIPE INSULATION. 4. HANGERS AND PIPING OF DISSIMILAR METALS SHALL BE DI- ELECTRICALLY SEPARATED FROM ONE ANOTHER. 0. ACCESS DOORS FURNISH STEEL ACCESS DOORS AND FRAMES, MIN. 16' X 20' OR AS SHOWN ON DRAWINGS, TO GENERAL CONTRACTOR FOR ALL LOCATIONS WHERE NECESSARY TO PROVIDE ACCESS TO CONCEALED VALVES, AND OTHER EQUIPMENT REQUIRING SERVICE OR INSPECTION. LOCATION, TYPE, SIZE AND NUMBER AS DETERMINED BY CONTRACTOR AND APPROVED BY TENANT CONSTRUCTION MANAGER TO SUIT EQUIPMENT REQUIREMENTS. GENERAL CONTRACTOR WILL INSTALL ACCESS DOORS AND FRAMES. 2. ACCESS DOORS LOCATED IN FIRE-RATED WALLS, FLOORS, CEILING -FLOOR OR CEILING -ROOF ASSEMBLIES SHALL BE FIRE RATED, UNDERWRITER'S LABORATORIES, INC., LISTED AND LABELED. 3. ACCESS DOORS SHALL BE FLUSH TYPE, MANUFACTURED FROM NiO. 14 GAUGE STEEL, COMPLETE WITH FLUSH FLANGE TYPE FRAMES MANUFACTURED FROM NO. 16 GAUGE STEEL, PROVIDED WITH ANCHORS. ACCESS DOORS SHALL BE SUITABLE FOR INSTALLATION IN WALL OR CEILING MATERIALS SHOWN IN ROOM FINISH SCHEDULES. ELECTRICAL MOTORS 1. FURNISH, INSTALL AND ALIGN ALL MOTORS REQUIRED FOR THIS EQUIPMENT. UNLESS THEY ARE FACTORY INSTALLED ON THE UNIT, ALL STARTERS AND ASSOCIATED WIRING AND SAFETY SNITCHES FOR SUCH MOTORS SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. STARTERS SHALL MEET ALL REQUIREMENTS AS DEFINED IN THE ELECTRICAL DIVISION OF THE SPECIFICATIONS. 2. DESIGN, CONSTRUCTION AND PERFORMANCE CHARACTERISTICS OF MOTORS SHALL CONFORM TO ALL APPLICABLE PROVISIONS OF LATEST NEMA, ANSI, ISEE STANDARDS FOR ELECTRICAL EQUIPMENT. ALL MOTORS SHALL BE SUITABLE FOR OPERATION ON VOLTAGE VARIATION OF PLUS OR MINUS 10%, 40 DEGREES C AMBIENT TEMPERATURE; HAVE A SERVICE FACTOR OF NOT LESS THAN 1.15. LOW VOLTAGE (24 VOLT) WIRING 1. THE CONTRACTOR IS TO INSTALL ALL LOW VOLTAGE WIRING REQUIRED FOR HIS EQUIPMENT. THIS WORK INCLUDES ALL TRANSFORMERS AND DEVICES TO MAKE THIS A COMPLETE FUNCTIONAL SYSTEM. 2. ALL WORK I5 TO CONFORM TO THE LATEST ADDITION N.E.0 AND TO DIVISION 16 ELECTRICAL SPECIFICATIONS. 3. ANY CONDUIT REQUIRED BY CODE OR THE LANDLORD WILL BE INSTALLED BY THE ELECTRICAL SUBCONTRACTOR. THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS. EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE PLUMBING SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: (REFER TO RESPONSIBILITY SCHEDULE FOR EXACT RESPONSIBILITIES) A. B. C. D. E. DIVISION 15 -MECHANICAL SECTION 15200 PLUMB I NG COMPLETE SANITARY PIPING SYSTEMS OF WASTE, DRAINS, AND VENTS. COMPLETE COLD AND HOT WATER PIPING SYSTEMS, APPURTENANCES AND INSULATION. PLUMBING FIXTURES AND EQUIPMENT AS SCHEDULED. COMPLETE NATURAL GAS PIPING SYSTEMS (AS APPLICABLE. REFER TO PLANS). TESTS AND ADJUSTMENTS. 2. BEFORE STARTING WORK, THIS CONTRACTOR SHALL EXAMINE THE ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL PLANS AND SPECIFICATIONS TO SEQUENCE, COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE PLUMBING SYSTEM. MATERIALS, AND EQUIPMENT WITH OTHER CONTRACTORS TO AVOID INTERFERENCES AND CONFRONTATIONS. 3. RELOCATION OF EXISTING WATER, GAS, WASTE, VENT, OR DRAINAGE LINES TO FACILITATE STORE DESIGN CRITERIA MUST BE INCLUDED IN BID PROPOSAL. B. PLUMBING EQUIPMENT C. GENERAL PIPING REQUIREMENTS GENERALLY, SANITARY AND POTABLE WATER LANDLORD. FIELD VERIFY EXACT CONNECTI BID AND NOTIFY THE TENANT'S CONSTRUCTI AS SHOWN ON THE PLANS OR AS STATED IN MUST VERIFY THE OPERABILITY OF ENTIRE FOLLOWS: TAPS WILL BE PROVIDED BY THE ON POINTS PRIOR TO SUBMITTING ON MANAGER IF CONDITIONS ARE NOT THE SPECIFICATIONS. CONTRACTOR SYSTEM PRIOR TO TIE IN AS A. SNAKE SANITARY FOR A DISTANCE OF 100 FEET AND REPORT ANY BLOCKAGE. 8. TEST WATER PRESSURE TO INSURE MINIMUM OF 50 PSI. 2. INSTALL ALL NECESSARY PIPE HANGERS, SADDLES, AND CARRIERS TO PROPERLY SUPPORT ALL PIPING AND FIXTURES. HANGERS SHALL SUIT TYPE OF PIPING PROVIDED AND BE SPACED AT A MAXIMUM SPAN OF 5 FEET. PROVIDE SWAY AND SEISMIC BRACING WHERE REQUIRED BY CODES. 3. ESCUTCHEONS SHALL BE CHROME PLATED, SIZE AS REQUIRED AND PLACED AT ALL PIPE PENETRATIONS AT WALLS, FLOORS, AND CEILINGS IN FINISHED AREAS. 4. FLASHING SHALL BE SEALED WATERTIGHT AND PERFORMED IN ACCORDANCE TO THE LANDLORD'S CRITERIA. USE A LANDLORD APPROVED ROOFING CONTRACTOR WHERE APPLICABLE. PIPING 1. SANITARY PIPING - NO PVC ALLOWED (STORM PIPING AS REQUIRED) A. WASTE. DRAIN AND VENT PIPING SHALL BE SERVICE WEIGHT, CAST IRON SOIL PIPE. VENT PIPING ABOVE FLOOR 2" OR SMALLER MAY BE GALVANIZED STEEL. B. JOINTS: BELOW FLOOR SLAB - BELL AND SPIGOT WITH CAULKED JOINTS PER CODE. C. PITCH WASTE LINES 2' AND SMALLER NOT LESS THAN 1/4" PER FOOT. PITCH LARGER MAINS NOT LESS THAN 1/8' PER FOOT. D. TALL A CL BASE OF EACH 501 STACK AT EACH CHANGE IN INS CLEANOUT AT L , DIRECTION, AT INTERVALS NOT OVER 50 FEET, AND ELSEWHERE AS SHOWN ON DRAWINGS OR REQUIRED BY LOCAL CODE. CLEANOUTS SHALL NOT BE INSTALLED IN PUBLIC AREAS WITHOUT SPECIFIC PERMISSION BY TENANT'S CONSTRUCTION MANAGER; BUT WHERE NECESSARY, THE WALL COVERS ARE TO BE STAINLESS STEEL AND THE FLOOR COVERS ARE TO BE BRASS (FLUSH WITH FINISHED FLOOR). PROVIDE COVERS WITH INSET AREA FOR CARPETED FLOOR LOCATIONS. ALL CLEAN-OUT LOCATIONS SHALL BE APPROVED BY THE TENANT'S CONSTRUCTION MANAGER. E. INSU LATE ALL ARMS UORIZONAL R OF PIPING LOCATED IN CEILING SPACES WHEN APPLICABLE. INSULATION TO BE AS SPECIFIED FOR WATER PIPING. F. INSULATE THE TRAP, SANITARY AND SUPPLY PIPES UNDER LAVATORY WITH 1/2' ARMSTRONG 'ARMAFLEX' PIPING INSULATION OR TRUEBRO MODEL 102W 'HANDI LAV GUARD' INSULATION KIT. TE PIPING TYPE 'L' DRAWN ER TUBE WITH TIN - 2. COND[7N5A P P SHALL BE WN COPP 95-5 ANTIMONY SOLDERED JOINTS AND WROUGHT COPPER FITTINGS WITH DIELECTRIC SEPARATION BETWEEN DISSIMILAR METALS. 3. POTABLE WATER PIPING: A. BELOW TYPE 'K', ANNEALED TEMPERED TUBE FOR PIPE GRADE: WEAL COPPER SIZES 2 INCHES AND SMALLER. BRAZE ALL JOINTS. B. ABOVE GRADE: TYPE 'L' DRAWN COPPER TUBE WITH WROUGHT COPPER FITTINGS AND 95-5 TIN - ANTIMONY SOLDER. C. INSTALL AIR CHAMBER SHOCK ABSORBERS IN PIPING SYSTEM TO PREVENT NOISE AND DAMAGE DUE TO WATER HAJMER. D. ALL BRANCH PIPING SYSTEM SHALL HAVE ACCESSIBLE SERVICE VALVE. PROVIDE SHUT OFF VALVES IN THE SUPPLY PIPING TO EVERY FIXTURE. PROVIDE ACCESS DOORS WHERE NECESSARY. E. PROVIDE WATER METER AND REMOTE READER PER LANDLORD'S CRITERIA OR LOCAL UTILITIES REQUIREMENTS IF APPLICABLE. REFER TO PLANS TO DETERMINED IF WATER METER IS REQUIRED. F. SECURE PIPE AT ANGLE STOPS. G. PROVIDE FLEXIBLE INSERTS AT ALL PIPE PENETRATIONS THROUGH FRAMING TO KEEP PIPES FROM HITTING FRAME WHEN IN OPERATION. 4. GAS PIPING A. PROVIDE A COMPLETE GAS PIPING SYSTEM IF APPLICABLE. REFER TO PLANS TO DETERMINE IF A GAS SYSTEM 15 REQUIRED. B. LOW PRESSURE (14' W.C. AND BELOW) GAS LINES SHALL BE BLACK STEEL, SCHEDULE 40, ASTM A-120, WITH MALLEABLE THREADED FITTINGS FOR 2' AND SMALLER, AND WITH WELDED JOINTS FOR 2 -1/2' AND LARGER. MEDIUM PRESSURE (ABOVE 14' W.C.) SHALL HAVE WELDED JOINTS. C. PROVIDE A GAS COCK, DIRT LEG, AND UNION CONNECTION TO EACH PIECE OF EQUIPMENT. PROVIDE GAS METER AND /OR REGULATOR AS REQUIRED. REGULATOR TO BE VENTED TO THE EXTERIOR. D. PITCH PIPING AT A UNIFORM GRADE OF 1/4" IN 15 FEET UPWARD IN DIRECTION OF FLOW. SUPPORT PIPING EVERY 5 FEET. SUPPORT AS REQUIRED BY LANDLORD CRITERIA, AS DETAILED ON DRAWINGS, OR BY STANDARD INDUSTRY PRACTICE, WHICHEVER IS MORE STRINGENT. E. GAS PIPING EXPOSED ON ROOF MUST BE PAINTED WITH RUST- INHIBITING PAINT. F. INSTALLATION, TESTING AND PURGING OF GAS PIPING SHALL BE DONE PER THE REQUIREMENTS OF THE LOCAL GAS COMPANY, LOCAL CODES, AND APPLICABLE NFPA 54 CODES. G. CONTACT AND COORDINATE GAS SERVICE AND METER REQUIREMENTS WITH THE LOCAL GAS COMPANY AND THE MALL'S MANAGER PRIOR TO BID. A. INSULATE ALL WATER AND INTERIOR CONDENSATE PIPING WITH 1' THICK (K=0.23 0 75 F) SNAP -ON FIBERGLASS PIPE INSULATION WITH AN ALL SERVICE JACKET TO MEET LOCAL CODES AND UL FLAME SPREAD RATING OF 25 AND SMOKE DEVELOPED RATINGS OF 50. APPROVED MANUFACTURER: MANVILLE MICRO -LOK. 6. TEST & STERILIZATION A. LEAKAGE TESTS SHALL BE PER LOCAL CODES, MINIMUM AS FOLLOWS: 1. TEST POTABLE WATER PIPING AND CONDENSATE PIPING AT 125 PSIG FOR SIX HOURS. 2. TEST DRAIN, WASTE, VENT PIPING BY A 10' WATER COLUMN FOR TWO HOURS. ALL JOINTS SHALL BE GAS AND WATER TiGHT. 3. TEST GAS PIPING WITH PER NFPA 54 CODES. 4. STERILIZE POTABLE HOT & COLD WATER LINES UPON COMPLETION OF SYSTEM. STERILIZE WATER SYSTEM IN ACCORDANCE WITH LOCAL CODES. A. 8. D. SCOPE OF WORK A. SCOPE Cr YORK E. PIP 1. 5. INSULATION F. TESTS THE F.P. CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE SPRINKLER SYSTEMS AS SHOWN ON THE DRAWINGS. CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: (REFER TO RESPONSIBILITY SCHEDULE FOR EXACT RESPONSIBILITIES) A. INSTALLATION OF NEW WET SPRINKLER SYSTEM AS REQUIRED TO PROVIDE COVERAGE IN ACCORDANCE WITH NFPA -13, LOCAL CODES, LANDLORD'S CRITERIA, AND INSURANCE CARRIERS FOR THE MALL AND TENANT. B. TAPS. RISERS, LATERALS, BRANCHES, VALVES, ALARMS, SPRINKLER HEADS AND ALL COMPONENTS REQUIRED FOR A COMPLETE SYSTEM. C. DESIGN DRAWINGS, CALCULATIONS, SUBMITTALS AND APPROVALS. D. PERMITS, FEES, AND CHARGES. E. TESTS AND TEST CERTIFICATES. F. COST FOR SHUT DOWN FEES. 2. THE CONTRACTOR THAT DOES THE ACTUAL SPRINKLER WORK 15 REQUIRED TO BE A LANDLORD APPROVED SPRINKLER CONTRACTOR. 3. BEFORE STARTING WORK, THE CONTRACTOR SHALL EXAMINE THE ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL PLANS AND SPECIFICATIONS TO SEQUENCE, COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE FIRE PROTECTION SYSTEM, MATERIALS, AND EQUIPMENT WITH OTHER CONTRACTORS TO AVOID INTERFERENCES AND CONFRONTATIONS. 4. RELOCATION OF EXISTING MAINS, LATERALS, BRANCHES AND RISERS TO FACILITATE STORE DESIGN CRITERIA M1JST BE INCLUDED IN BID PROPOSAL. SHOP DRAWINGS 3. C. EQUIPMENT THE FIRE PROTECTION CONTRACTOR SHALL PREPARE DETAILED SHOP DRAWINGS AND CALCULATIONS FOR HIS WORK. SUBMIT SIX (6) COPIES TO GENERAL CONTRACTOR FOR APPROVAL. NO WORK SHALL BEGIN UNTIL TENANT'S CONSTRUCTION MANAGER APPROVES HEAD AND PIPING LOCATIONS. 2. THE FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR SUBMITTING COORDINATED DRAWINGS, CALCULATIONS, HEAD TYPES AND COLORS TO ALL AUTHORITIES HAVING JURISDICTION FOR APPROVAL. NO WORK SHALL BEGIN UNTIL ALL APPROVALS HAVE BEEN RECEIVED. A COPY OF THE LETTER OF APPROVAL FROM THE LANDLORD'S INSURANCE RATING BUREAU SHALL BE FORWARDED TO THE LANDLORD'S AGENT AND TO THE TENANT'S CONSTRUCTION MANAGER. SPRINKLER HEADS: A. ALL SPRINKLER HEADS SHALL BE NEW (EXISTING HEADS SHALL BE REPLACED AS NECESSARY), U.L., F.N. LISTED AND APPROVED AUTOMATIC SPRAY TYPE AS MANUFACTURED BY CENTRAL SPRINKLER CO., GLOBE, GRINNELL, RELIABLE, STAR, OR VIKING. B. ALL SPRINKLER HEADS SHALL BE RATED FOR 165 "F UNLESS INDICATED OTHERWISE ON DRAWINGS OR REQUIRED BY LOCAL CODES. C. ALL SALES FLOORS HEADS ARE TO HAVE BE FACTORY APPLIED COLOR FINISH TO MATCH ARCHITECTURAL CEILING FINISH. VERIFY HEAD TYPES AND COLORS WITH TENANT'S CONSTRUCTION MANAGER AND SUBMIT WITH SPRINKLER DRAWINGS FOR PERMIT. D. SPRINKLER HEAD TYPES SHALL BE AS FOLLOWS: 1. FINISHED CEILING (SALES AREA) - FULLY RECESSED /CONCEALED TYPE 2. FINISHED CEILING NON -SALES AREA) - SEMI -- RECESSED TYPE 3. NO- CEILING - CHROME UPRIGHT TYPE. NOTE:SEMI- RECESSED HEADS SHALL PROTRUDE NO MORE THAN 1' BELOW LEVEL OF CEILING OF SOFFIT. ALL HORIZONTAL SPRINKLER RUNS AT SIDEWALL SOFFITS SHALL BE CONCEALED WITHIN SOFFIT FRAMING. GENERAL. PIPING 1 DIVISION 15 -MECHANICAL SECTION 15300 FIRE PROTECTION A FIRE PROTECTION SYSTEM STUB IN SHALL BE FURNISHED BY THE LANDLORD. SPRINKLER SPACING SHALL NOT EXCEED 130 SQ. FT. IN "SALES' AREAS AND 100 SQ. FT. IN 'STOCK' AREAS. COMPLY WITH LANDLORD'S DESIGN CRITERIA. PIPE SIZING SHALL BE BASED ON NFPA ORDINARY HAZARD. 2. ER LINES INSTALLED CONCEALED, ALL SPRINKLER SHALL BE CEALE , AVOIDING INTERFERENCE WITH LIGHTS, DUCTS, PIPES, STORAGE DECK, ETC. FIRE PROTECTION CONTRACTOR SHALL PREPARE COORDINATED SHOP DRAWINGS INDICATING THE LOCATIONS OF ALL SPRINKLER HEADS, SPRINKLER LINES, LIGHTS, DIFFUSERS, GRILLES AND REGISTERS PRIOR TO INSTALLATION. HORIZONTAL SPRINKLER RUNS AT MERCHANDISE SOFFITS SHALL BE PLACED INSIDE SOFFIT STRUCTURE. VERTICAL DROPS FROM CEILING TO MERCHANDISE SOFFIT SHALL BE LOCATED FLUSH AGAINST DEMISING WALLS. 3. WHERE POSSIBLE. REWORK THE EXISTING SPRINKLER SYSTEM TO MEET THE NEW REQUIREMENTS OF THIS DESIGN. RELOCATE ALL MAINS AND BRANCHES INTERFERING WITH CEILING HEIGHTS, EQUIPMENT, AND MAJOR COMPONENTS INCLUSIVE OF ADJACENT TENANTS AND MALL COMMON AREAS. REMOVE ALL UNUSED PIPING. 4. LOCATIONS OF ALL HEADS SHOULD BE APPROVED BY THE LOCAL FIRE PROTECTION OFFICIAL AND THE TENANT'S CONSTRUCTION MANAGER BEFORE INSTALLATION. HEADS MUST BE LOCATED IN THE CENTER OF CEILING TILES AND IN A SYMMETRICAL PATTERN WITH OTHER CEILING FIXTURES. ADDITIONAL MONIES WILL NOT BE ALLOCATED FOR ADDITIONAL HEADS REQUIRED BY FIELD FIRE INSPECTOR AFTER BIDS ARE ACCEPTED. HEADS IN MERCHANDISE BAYS SHALL BE CENTERED SIDE TO SIDE AND FRONT TO BACK. 5 PROVIDE AND INSTALL A VALVED TEST CONNECTION FOR THE SPRINKLER SYSTEM AS REQUIRED OR REQUESTED BY THE MALL, LOCAL INSPECTOR, OR INSURANCE CARRIER. COORDINATE LOCATION WITH TENANT'S CONSTRUCTION MANAGER AND LOCAL FIRE PROTECTION OFFICIAL PRIOR TO ROUGH -IN. 6. 2. 3. 4. SPRINKLER HEADS LOCATED IN STOCK, CORRIDOR ON TOILET ROOM CEILINGS OR WALLS BELOW 8' -O' ABOVE THE FINISHED FLOOR ARE TO BE PROTECTED WITH APPROVED GUARDS. ING: SCHEDULE 40, BLACK STEEL PIPE, ASTM A-53 FOR FERROUS PIPING. WELDED AND SEAMLESS, ANSI 8-36 -10-70 FOR WROUGHT STEEL PIPE. CAST IRON OR MALLEABLE IRON SCREWED FITTINGS FOR PIPES 2 INCHES AND SMALLER. SCREWED OR CAST IRON FLANGED JOINTS FOR PIPES LARGER THAN 2 INCHES. GALVANIZED OR BLACK MALLEABLE IRON WITH BRASS SEAT SCREWED UNIONS FOR PIPES 2 INCHES AND SMALLER. VICTAULIC TYPE COUPLINGS ARE ACCEPTABLE. WHERE APPROVED BY CODE AND THE LANDLORD. WHEN COMPLETED, THE ENTIRE FIRE PROTECTION PIPING SYSTEM SHALL BE HYDROSTATICALLY TESTED AS REQUIRED BY THE RULES AND REGULATIONS OF THE AUTHORITIES HAVING JURISDICTION. SYSTEM SHALL SHOYINIO SIGNS OF LEAKAGE CR OTHER DEFECTS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO THE WORK OF THE OTHER CONTRACTORS OR TO THE BUILDING, OR TO ITS CONTENTS, PEOPLE, ETC., CAUSED BY LEAKS IN ANY OF THE EQUIPMENT INSTALLED BY HIM. ALL REPAIRS OR REPLACEMENT OF DAMAGES SHALL BE AT THIS CONTRACTOR'S EXPENSE. 2. PROPERLY COMPLETED AND SIGNED "SPRINKLER CONTRACTOR'S MATERIAL AND TEST CERTIFICATES' SHALL BE FURNISHED TO THE LANDLORD, AUTHORITIES HAVING JURISDICTION, AND TENANT'S CONSTRUCTION MANAGER. B. C. A. B. C. D. E. F. G. H. J. K. DIVISION 15 - MECHANICAL SECTION 15500 HEATING, VENTILATION, AND AIR CONDITIONING THE HVAC CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE MECHANICAL SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING:(REFER TO RESPONSIBILITY SCHEDULE FOR EXACT RESPONSIBILITIES) ROOFTOP UNITS, EQUIPMENT, AND APPURTENANCES. DUCTWORK, FITTINGS. DAMPERS, AND INSULATION. HYDRONIC PIPING AND INSULATION (A5 APPLICABLE, REFER TO PLANS). REFRIGERANT PIPING (AS APPLICABLE, REFER TO PLANS). DIFFUSERS, GRILLES, AND REGISTERS. CURBS AND STEEL FRAMING FOR SUPPORT (AS APPLICABLE, REFER TO PLANS). TESTING, ADJUSTING, AND BALANCING. OPERATIONS MANUALS. TEMPERATURE CONTROLS AND RELATED DIAGRAMS. SEQUENCES OF OPERATION. CONNECTION TO ANY LANDLORD ENERGY MANAGEMENT SYSTEM. 3. BEFORE STARTING WORK, THIS CONTRACTOR SHALL EXAMINE THE ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL PLANS AND SPECIFICATIONS TO SEQUENCE, COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE HVAC SYSTEM, MATERIALS, AND EQUIPMENT WITH OTHER CONTRACTORS TO AVOID INTERFERENCES AND CONFRONTATIONS. HVAC EQUIPMENT 1. PRIMARY HEATING, VENTILATION AND AIR CONDITIONING UNITS. A. PRIMARY HEATING, VENTILATION, AND AIR CONDITIONING UNITS ARE TO BE BY CARRIER AS SCHEDULED. ALL COMPRESSORS ARE TO INCLUDE A 5-YEAR EXTENDED WARRANTY. B. EQUALS EQUIPMENT AS MANUFACTURED BY TRANE OR YORK ARE ACCEPTABLE. C. ALL EQUIPMENT SHALL BE COMPLETE IN EVERY RESPECT WITH ALL DEVICES, APPURTENANCES, AND ACCESSORIES PROVIDED TO MEET THE DESIGN INTENT AND OPERATION OF THE SYSTEMS SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN. D. EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. ALL AIR CONDITIONING EQUIPMENT MUST HAVE A CONDENSATE DRAIN AND BE TRAPPED IN ACCORDANCE WITH MANUFACTURERS DATA. SEE DRAWINGS FOR ADDITIONAL DETAILS. E. SECONDARY DRAIN PANS ARE REQUIRED TO BE INSTALLED BENEATH ALL INDOOR AIR CONDITIONING EQUIPMENT WITH THE EXCEPTION OF VAV BOXES. SECONDARY PANS ARE TO PROTECT ENTIRE UNIT. PROVIDE CONDENSATE PUMPS, AS REQUIRED. CONDENSATE SHALL BE DIRECTED TO MOP SINK OR AS SPECIFIED ON PLANS. 2. VARIABLE AIR VOLUME BOXES (VAV) A. WHERE SHOWN ON DRAWINGS. PROVIDE VAV BOXES COMPLETE WITH CONTROLS, HEATING COILS (FANS AS REQUIRED). ALL DUCT CONNECTIONS FLEXIBLE DUCT /PIPE CONNECTIONS SHALL BE PROVIDED BY THE CONTRACTOR. 3. EXHAUST FANS S A. WHERE SHOWN ON DRAWINGS, PROVIDE A TOILET EXHAUST FAN UNIT COMPLETE WITH GRAVITY BACK DRAFT DAMPERS. ALL DUCTWORK, ROOF AND CAPS TO PROVIDE COMPLETE EXHAUST OPENINGS NECESSARY DE A CCMPL SYSTEM SHALL BE PROVIDED BY THE CONTRACTOR. REFER TO PLANS FOR APPLICABILITY. 4. BASEBOARD, CABINET, AND UNIT HEATERS A. WHERE SHOWN ON DRAWINGS, PROVIDE ELECTRIC HEATERS COMPLETE WITH ELECTRIC HEATING COIL. CONTROLS, AND INTEGRAL THER OSTAT. 5. INLINE PUMPS A. WHERE SHOWN ON DRAWINGS PROVIDE AN INLINE CLOSE COUPLED PUMP(S), BRONZE FITTED, PUMPS SHALL BE FURNISHED WITH BRONZE CASE WEARING RINGS, BRONZE SHAFT SLEEVE AND MECHANICAL SHAFT SEAL RATED FOR. PUMPS TO BE 50 CONSTRUCTED THAT THEY MAY BE MOUNTED IN A HORIZONTAL OR TICAL PIPE LINE. MOTOR TO BE 175 YER NE. MD 1750 RPM UNLESS NOTED OTHERWISE. 6. VIBRATION ISOLATION DEVICES A. VIBRATION ISOLATION DEVICES SHALL BE PROVIDED IN ALL SUPPORTS BETWEEN VIBRATING EQUIPMENT (FANS. ROOFTOP UNITS, AIR HANDLERS, FAN POWERED VAV BOXES, ETC.) AND STRUCTURE. B. VIBRATING EQUIPMENT HUNG FROM STRUCTURE SHALL BE ISOLATED WITH RUBBER AND SPRING DEVICES. VIBRATING EQUIPMENT SUPPORTED FROM FLOOR OR DECK SHALL BE ISOLATED WITH HOUSED SPRING MOUNT DEVICES. C. EXAMINE DEAD LOAD AND OPERATING LOAD CONDITIONS WHEN SELECTING DEVICES. ADJUST FOR PROPER ALIGNMENT AND LOADING. AVOID 'GROUNDING" THE ISOLATOR. D. CHECK HANGER ROD SIZE FOR ALLOWABLE LOADS AT THE ISOLATING DEVICE AND AT THE UPPER AND LOWER ATTACHMENTS TO STRUCTURES, DUCTS, E ETC. EQUIPMENT, PGENT E. CONSULT MANUFACTURER FOR APPLICATION DATA. 7. CURBS AND STEEL FRAMING FOR SUPPORT A. THIS CONTRACTOR WILL PROVIDE ALL NECESSARY CURBS AND STEEL FRAMING REQUIRED TO INSTALL ALL HVAC EQUIPMENT AS DESCRIBED CR IMPLIED ON THE DRAWINGS. CURBS SHALL BE A MINIMUM OF 14' HIGH, OF THE SAME MANUFACTURER OF THE EQUIPMENT SUPPORTED. INSULATE UNDER THE COMPRESSOR SECTION TO PREVENT CONDENSATION. ALL CURBS MUST BE INSTALLED SO THAT TOP OF CURBS ARE 'DEAD" LEVEL. ALL PENETRATIONS OF EXISTING STRUCTURE SHALL BE DONE IN ACCORDANCE TO THE LANDLORD'S GUIDELINES AT THIS CONTRACTOR'S EXPENSE. METAL DUCVERK - NO FIBERGLASS DUCT ALLOWED 1. NO DUCTWORK SHALL BE FABRICATED PRIOR TO APPROVAL BY THE TENANT'S CONSTRUCTION MANAGER. SIGNIFICANT DEVIATIONS FROM DESIGN MUST BE APPROVED BY TENANT'S CONSTRUCTION MANAGER PRIOR TO FABRICATION OR INSTALLATION. ALL DUCT MAINS ARE TO BE RECTANGULAR UNLESS NOTES OTHERWISE. ALL DUCT BRANCHES TO DIFFUSERS ARE TO BE ROUND RIGID DUCT. 1. (FLEXIBLE DUCT CONNECTIONS TO THE DIFFUSER ARE NOT ALLOWED ON THE SALES FLOOR) 2. EXCEPT AS OTHERWISE INDICATED, FABRICATE AND INSTALL RECTANGULAR DUCTS WITH GALVANIZED SHEET STEEL, IN ACCORDANCE WITH SMACNA 'HVAC DUCT CONSTRUCTION STANDARDS" OF THE LATEST EDITION. CONFORM TO THE REQUIREMENTS IN THE REFERENCED STANDARD FOR METAL THICKNESS, REINFORCING TYPES AND INTERVALS, TIE ROD APPLICATIONS, AND JOINT TYPES AND INTERVALS. 3. EXCEPT WHERE OTHERWISE INDICATED, CONSTRUCT DUCT SYSTEMS TO THE FOLLOWING PRESSURE CLASSIFICATIONS: (VERIFY WHETHER RETURN OR EXHAUST DUCT IS POSITIVE OR NEGATIVE PRESSURE). A. SUPPLY DUCTS: 2 INCHES WATER GAUGE, POSITIVE PRESSURE B. RETURN AND EXHAUST DUCTS: 2 INCHES WATER GAUGE, NEGATIVE PRESSURE. PRESSURE TEST DUCTS FOR LEAKAGE. REMAKE LEAKING JOINTS AND APPLY SEALANTS AS REQUIRED TO FABRICATE A SYSTEM THAT DOES NOT EXCEED 57 LEAKAGE OR LESS AS STATED BY PRESSURE CLASS RATINGS iN SMACNA STANDARDS. 4. AS A MINIMUM, CROSSBREAK ALL FLAT SURFACES OR REINFORCE WITH A BEAD APPROXIMATELY 3 /B' WIDE X 3/16' DEEP ON 12' CENTERS TO PREVENT VIBRATIONS. 5. INSTALL DOUBLE THICKNESS TURNING VANES IN ALL RIGHT ANGLE ELBOWS. 6. INSTALL RIGID ROUND AND RECTANGULAR METAL DUCT WITH SUPPORT SYSTEMS INDICATED IN SMACNA STANDARDS. SUPPORT HORIZONTAL DUCTS WITHIN 2 FEET OF EACH ELBOW AND WITHIN 4 FEET OF EACH BRANCH INTERSECTION USING DOUBLE STRAP HANGERS ON EACH SIDE OF FITTING. SUPPORT VERTICAL DUCTS AT A MAXIMUM INTERVAL OF 16 FEET AND AT EACH FLOOR. NO WOW SHALL BE USED TO SUPPORT OR BRACE DUCTS. PROVIDE SWAY AND SEISMIC BRACING AS REQUIRED BY STATE AND LOCAL CODES OR BY LANDLORD. 7. WHERE DUCTS PASS THROUGH ROOFS AND FLOORS, PROVIDE AS MINIMUM 1- 1/2'X1--1/2' X1/8" STEEL ANGLE FRAMES AT EACH SIDE OF OPENING. THE ANNULAR SPACE BETWEEN DUCT AND ANGLE FRAMES SHALL BE CAULKED WITH SILICONE SEALANT OR FIREPROOFED AS REQUIRED BY ASSEMBLY FIRE RATING. 8. ALL TRAVERSE JOINTS AND SEAMS IN SUPPLY AIR DUCT SHALL BE SEALED AIR TIGHT WITH DAP CMC DUCT SEALER. JOINTS ALSO SHALL BE RIVETED OR CONNECTED WITH SHEET METAL SCREWS. 9. SOFT EIASTOMER BUTYL GASKET WiTH ADHESIVE BACKING SHALL BE USED TO SEAL FLANGED JOINTS. 10. DUCT TRANSITIONS SHALL NOT EXCEED 30 DEGREES SLOPE EXCEPT AS SPECIFICALLY NOTED OTHERWISE. 11. PROVIDE ACCESS TO ALL MOTORIZED DAMPERS, FIRE DAMPERS, CONTROLS, AND OTHER ITEMS IN DUCTWORK THAT REQUIRE SERVICE OR INSPECTION. IF THE ACCESS PANEL LOCATION I5 EXPOSED TO THE SALES AREA, IT MUST BE APPROVED BY THE TENANT'S CONSTRUCTION MANAGER PRIOR TO INSTALLATION. LAY -IN SUPPLY AND RETURN AIR DIFFUSERS, GRILLES AND REGISTERS WITH PLASTER FRAMES MAY BE USED AS ACCESS LOCATIONS. D. 12. FLEXIBLE CONNECTIONS A. FLEXIBLE COLLARS SHALL BE PROVIDED IN ALL CONNECTIONS BETWEEN VIBRATING EQUIPMENT (FANS, ROOFTOP UNITS, AIR HANDLERS, FAN POWERED VAV BOXES, ETC.) AND DUCTS OR CASINGS. ALSO, PROVIDE FLEXIBLE CONNECTIONS WHERE DUCTS CROSS BUILDING EXPANSION JOINTS. 8. FLEXIBLE CONNECTIONS SHALL CONSTRUCTED OF NEOPRENE - COATED FLAMEPROOF FABRIC. PROVIDE ADEQUATE JOINT FLEXIBILITY TO ALLOW FOR MOVEMENT AND PREVENT THE TRANSMISSION OF VIBRATION. C. FLEXIBLE CONNECTION IS TO BE RATED FOR THE OPERATING PRESSURE OF THE SYSTEM. 13. FIRE DAMPERS A. PROVIDE PRIMARY FIRE DAMPERS WHERE INDICATED OR REQUIRED BY CODES. DAMPERS SHALL BE DESIGNED FOR HORIZONTAL OR VERTICAL FLOW OF AIR AS REQUIRED. FIRE DAMPERS SHALL BE UL LABELED. B. FIRE DAMPERS SHALL HAVE THE BLADES OUT OF THE AIRSTREAM AND A 165'F FUSIBLE LINK, TYPE A. AS MINIMUM. C. PROVIDE ALL NECESSARY FRAMING AND SLEEVES FOR DAMPER MOUNTING PER UL AND CODE REQUIREMENTS. D. PROVIDE DUCT ACCESS DOORS IN AN ACCESSABLE LOCATION FOR ALL FIRE DAMPERS. DOOR I5 TO BE 20 GA GALVANIZED DOOR WITH QUICK-OPENING LATCH AND PIANO HINGE. 14. FLEXIBLE AIR DUCT A. FLEXIBLE AIR DUCT SHALL BE 1' INSULATED CLASS 1 AND RATED FOR THE OPERATING PRESSURE OF THE SYSTEM. DUCT CONSTRUCTION MATERIAL (PLASTIC, CLOTH, ALUMINUM) MUST ADHERE TO LOCAL CODES AND LANDLORD'S REQUIREMENTS AND BE INCLUDED AS SUCH IN THE BID. B. FLEXIBLE AIR DUCT MAY ONLY BE USED IN VERTICAL APPLICATIONS WITH PRIOR APPROVAL FROM TENANT'S CONSTRUCTION MANAGER. C. FLEXIBLE DUCT SHALL NOT EXTEND OVER 5'-0' IN LENGTH AT ANY ONE LOCATION. 15. SUPPLY AIR TAKE-OFF FITTINGS A. PROVIDE CONICAL OR "BELL - MOUTH' TAKE-OFFS FROM MAIN DUCTWORK TO ROUND BRANCHES. INSTALL PER MANUFACTURER'S INSTRUCTIONS. B. PROVIDE 45' RECTANGULAR TAKE -OFFS FROM MAIN DUCTWORK TO RECTANGULAR BRANCHES. 16. DAMPER'S A. PROVIDE MANUAL LOCKING QUADRANT VOLUME CONTROL DAMPERS WITH HANDLE OPERATORS IN EACH BRANCH DUCT AND AS SHOWN ON PLANS TO FACILITATE AIR BALANCING. B. WHERE ACCESS TO BALANCING DAMPER I5 RESTRICTED, YOUNG'S REGULATORS SHALL BE USED. C. ALL RECTANGULAR DAMPERS IN OUTSIDE AIR, RELIEF AIR. OR RETURN AIR DUCTS ARE TO BE OF OPPOSED BLADE TYPE. ALL OUTSIDE AIR DUCT DAMPERS MUST ALSO BE OF THE LOW LEAKAGE TYPE. D. ALL MOTORIZED DAMPERS NOT FURNISHED WITH EQUIPMENT ARE TO BE HONEYWELL DAMPERS. 17. DIFFUSERS, GRILLES, AND REGISTERS A. PROVIDE DIFFUSERS GRILLES AND REGISTERS AS SCHEDULED. DEVICES TO BE COMPLETE WITH DAMPERS FRAMES AND ALL ACCESSORIES. FINISH AS INDICATED. B. INSTALL ALL AIR DEVICES AS LOCATED ON THE ARCHITECTURAL REFLECTED CEILING PLAN. C. APPROVED MANUFACTURERS: TITUS IS SPECIFIED. EQUALS BY METALAIRE CR KRUEGER I5 ACCEPTABLE. 18. MEDIUM PRESSURE DUCT A. WHERE DUCTWORK 15 SPECIFICALLY NOTED AS MEDIUM PRESSURE, IT SHALL BE CONSTRUCTED IN ACCORDANCE WITH SMACNA STANDARDS FOR A PRESSURE RATING OF 3 INCHES WATER COLUMN MINIMUM OR LARGER AS REQUIRED BY LANDLORD. B. ALL GAUGES AND REINFORCEMENT MUST MEET WITH THE LATEST EDITION OF SMACNA STANDARDS FOR MEDIUM PRESSURE DUCT AND WITH THE LANDLORD'S CRITERIA. C. ALL OTHER ITEMS FROM METAL DUCTWORK SPECIFICATION SECTION APPLY TO THIS SECTION 19. DUCTWORK INSULATION A. INSTALL INSULATION PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS, AND IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES. INSULATION MUST COMPLY WITH NFPA 90A. B. DUCT SIZES SHOWN ON DRAWINGS ARE INSIDE CLEAR DIMENSIONS. INSULATE SUPPLY AND RETURN AIR RECTANGULAR DUCTWORK WHERE SHOWN ON PLAN. DUCTWORK SHALL BE EXTERNALLY WRAPPED WITH 1 1/2' THICK, FOIL FACED FIBERGLASS INSULATION. C. ALL ROUND AND OUTSIDE AIR DUCTWORK ABOVE THE CEILING SHALL BE EXTERNALLY INSULATED WITH A MINIMUM OF 1" THICK, 1 -1/2 LB. DENSITY (R=5.6) DUCT WRAP WITH VAPOR BARRIER. VAPOR BARRIER I5 TO BE MAINTAINED THROUGHOUT DUCT SYSTEM. ALL JOINTS MUST BE TAPED SD THAT NO INSULATION FIBER IS VISIBLE. EXTEND DUCTWORK INSULATION WITHOUT INTERRUPTION THROUGH WALLS, FLOORS, AND SIMILAR PENETRATIONS. D. DUCKWORK LOCATED IN THE CONDITIONED SPACE SHALL NOT BE INSULATED UNLESS OTHERWISE NOTED ON PLANS. INSULATE ALL DUCT DROPS OR THE FIRST 20 FEET OF DUCT AT THE HVAC UNITS IN ALL CASES. E. ALL INSULATION SHALL HAVE A FLAME SPREAD RATING OF NOT MORE THAN 25 AND A SMOKE DEVELOPED RATING OF NO HIGHER THAN 50 WHEN TESTED IN ACCORDANCE WITH ASTM C 411, OR AS REQUIRED BY LOCAL CODES. 20. SYSTEM CLEANOUT A. DUCTWORK AND AIR HANDLING EQUIPMENT IS TO BE CLEANED OUT AND BLOWN OUT BEFORE PAINTING IS STARTED BY THE GENERAL CONTRACTOR. B. FILTERS MUST BE IN UNITS AT ANY TIME FANS ARE OPERATED. HYDRONIC PIPING 2. 3. PROVIDE A COMPLETE HYDRONIC PIPING SYSTEM IF APPLICABLE. REFER TO PLANS TO DETERMINE IF A HYDRONIC SYSTEM IS REQUIRED. PIPING A. HYDRONIC PIPING FOR CHILLED WATER AND /CR HEATING WATER AND /OR CONDENSER WATER SHALL BE ASTM A-120, SCHEDULE 40, ERN, BLACK STEEL PIPE WITH PLAIN ENDS. INSTALL STEEL PIPE WITH WELDED JOINTS WHERE PIPE IS 2 -1/2 INCH AND LARGER. INSTALL STEEL PIPE WITH THREADED JOINTS AND FITTINGS OR INSTALL TYPE 'K" ANNEALED TEMPERED COPPER TUBE WITH SILFOS JOINTS FOR 2 INCH AND SMALLER PIPE. PROVIDE DIELECTRIC UNIONS BETWEEN DISSIMILAR METALS. ALL PIPING SHALL. BE iN STRICT CONFORMANCE WITH ASTM, ASA, AND LANDLORD'S REQUIREMENTS, WHICHEVER 15 MOST STRINGENT. UNIONS OR FLANGES MUST BE USED AT EQUIPMENT CONNECTIONS WHERE SERVICE OR REMOVAL MAY BE REQUIRED. B. ALL PIPING AND EQUIPMENT SHALL BE PRESSURE TESTED WITHOUT LEAKAGE AT A MINIMUM PRESSURE OF 125 PSI. C. ALL HYDRONIC PIPING AND EQUIPMENT CONNECTED TD THE HVAC PIPING SYSTEM SHALL BE CLEANED AND FLUSHED. REMOVE, CLEAN. AND REPLACE STRAINER SCREENS. FILL TENANT'S SYSTEM WITH DOMESTIC WATER AND VENT ALL PIPING AND EQUIPMENT PRIOR TO CONNECTION TO THE LANDLORD'S SYSTEM. CONTRACTOR SHALL NOT FILL TENANT'S SYSTEM WITH WATER FROM THE LANDLORD'S SYSTEM UNLESS SPECIFICALLY INSTRUCTED TO DO SO FROM THE LANDLORD'S FIELD REPRESENTATIVE. D. PRIOR TO CONNECTION TO THE LANDLORD'S SYSTEM, CONTRACTOR SHALL OBTAIN WRITTEN CONFIRMATION FROM THE LANDLORD'S FIELD REPRESENTATIVE. THAT ALL TESTING, FLUSHING, AND PROPER FILLING OF THE TENANT'S SYSTEM HAS BEEN COMPLETED IN ACCORDANCE TO THE LANDLORD'S REQUIREMENTS AND THAT THE TENANT'S SYSTEM IS READY TO BE CONNECTED TO THE LANDLORD'S SYSTEM. VALVES A. GATE VALVES, 2 -INCH AND SMALLER: CLASS 150, BODY AND UNION BONNET OF ASTM B 62 CAST BRONZE WITH THREADED CR SOLDER ENDS, INTEGRAL SEAT, RENEWABLE SOLID BRONZE WEDGE DISC, RISING STEM, SCREWED BONNET AND RE- PACKABLE UNDER PRESSURE. BALL VALVES ARE ACCEPTED AS AN EQUAL SUBSTITUTION. B. GATE VALVES, 2 -1/2 INCH AND LARGER: CLASS 125 CAST IRON BODY, RENEWABLE BRONZE SEATS AND SOLID WEDGE DISC, RISING STEM, FLANGED ENDS. AND RE- PACKABLE UNDER PRESSURE. C. SWING CHECK VALVES, 2 -INCH AND SMALLER: CLASS 150, CAST BRONZE BODY AND CAP CONFORMING TO ASTM B 62 WITH HORIZONTAL SWING, Y- PATTERN, RENEWABLE BRONZE DISC. AND HAVING THREADED OR SOLDERED ENDS. D. SWING CHECK VALVE, 2 -1/2 INCH AND LARGER: CLASS 125 CAST IRON BODY AND BOLTED CAP. HORIZONTAL SWING, RENEWABLE BRONZE DISC, FLANGED ENDS AND CAPABLE OF BEING REFITTED WHILE THE VALVE REMAINS IN THE LiNE. E. COMBINATION BALANCING AND SHUT-OFF VALVES: BELL & GOSSETT CIRCUIT SETTER WITH LOCKING SETPOINT. A CIRCUIT SETTER BALANCE WHEEL MUST BE INCLUDED WITH 0 & M MANUAL. F. FLOW METER: BELL AND GOSSETT THERMOFLO INDICATOR MODEL TFI. E. F. MO$�13°1 4. PIPING SPECIALTIES 5. GENERAL INSTALLATION 6. INSULATION REFRIGERANT PIPING G. Fl 2. MATERIALS A. REFRIGERANT PIPING SHALL BE TYPE 'L' DRAWN COPPER TUBING (ASTM B88), WROUGHT COPPER OR CAST BRONZE FITTINGS (ANSI B16.22), WI SILFOS -5 SOLDERED JOINTS. B. SERVICE VALVES. CHARGING PORTS, FILTER - DRIER, SIGHT GLASS, AND A THERMOSTATIC EXPANSION VALVE (TXV) SHALL BE INSTALLED FOR EA SYSTEM AS A MINIMUM. 3. INSTALLATION L A. SIZE LINES WITH ADEQUATE LIFT TRAPS AND DOUBLE SUCTION RISERS AS NECESSARY TO MEET THE NEEDS OF EQUIPMENT SPECIFIED, FIELD CONDITIONS, AND EQUIPMENT MANUFACTURER'S RECOMMENDATIONS. B. PRESSURE TEST FOR LEAKS WITH INERT GAS PSIG. R ST TH AN I AT 250 PS EDD LEAKING JOINTS AND RETEST UNTIL SYSTEM I5 TIGHT. EVACUATE GAS AND CHARGE SYSTEM. RE -TEST SYSTEM AND CHECK FOR LEAKS WITH HALIDE LEAK DETECTOR. ALL LEAKING JOINTS MUST BE COMPLETELY RE- DONE UNTIL NO LEAKS EXIST. C. UPON COMPLETION OF TESTING, BUT BEFORE INSULATION I5 APPLIED, PIPING MUST BE INSPECTED BY A REPRESENTATIVE OF THE LOCAL GOVERNING AUTHORITY AS NECESSARY. D. REFRIGERANT LINES SHALL BE INSULATED WITH 1 INCH THICK RUBATEX OR ARMSTRONG REFRIGERANT PiPE INSULATION IN ACCORDANCE WITH INDUSTRY STANDARDS. SYSTEM TESTING, ADJUSTING, AND BALANCING 1. TESTING, ADJUSTING AND BALANCING OF ALL WORT( SHALL BE MADE BY AN INDEPENDENT CONTRACTOR WHO IS CURRENTLY LICENSED ASSOCIATED AIR BALANCING COUNCIL (AABC) NATIONAL ENVIRONMENTAL OR NVIRONMENT BALANCING BUREAU (NEBB) BALANCING CONTRACTOR. NO OTHER BALANCE REPORTS WILL BE REVIEWED OR ACCEPTED. ALL BALANCING WORK MUST BE COMPLETE AND DONE IN ACCORDANCE WITH THE MOST RECENT STANDARDS OF THEIR SOCIETY. PAYMENT OF ALL COSTS FOR TESTING SHALL BE MADE BY THE HVAC CONTRACTOR. 2. THE HVAC CONTRACTOR SHALL INSTALL NEW FILTERS IN ALL UNITS PRIOR TO THE AIR BALANCE. THE COMPLETE AIR BALANCE SHALL TAKE PLACE WITH OUTSIDE AIR DAMPERS IN MINIMUM POSITION. 3. BALANCE AIR AND WATER QUANTITIES TO WITHIN + 5X OF THAT INDICATED ON THE DRAWINGS. ANY REQUIRED CHANGES IN SHEAVES, BELTS, PULLEYS, OR THE ADDITION OF DAMPERS REQUIRED TO ACHIEVE SPECIFIED FLOW RATES SHALL BE PERFORMED BY THE HVAC CONTRACTOR WITH NO ADDITIONAL COST TO THE 4. THE BALANCE REPORT SHALL INCLUDE AS A MINIMUM THE FOLLOWING INFORMATION: A. AABC OR NEBB CERTIFICATION NUMBER AND SIGNATURE OF BALANCING CONTRACTOR. INSTRUMENTATION LIST WITH LAST CALIBRATION DATES. MAKE AND MODEL NUMBERS OF ALL HVAC EQUIPMENT TESTED. AIR UM AND STATIC PRESSURE READINGS (DISCHARGE AND SUCTION) MEASURED BY PITOT TUBE DUCT TRAVERSE AT THE UNIT. MOTOR NAMEPLATE DATA WITH ACTUAL FIELD VOLTAGE AND AMPERAGE READINGS FOR EACH LEG. MOTOR AND FAN RAMS, SHEAVE SIZES AND BELT SIZES. OUTSIDE, RETURN, MIXED AND SUPPLY AIR TEMPERATURES AT FULL COOLING. WATER BALANCE DATA INCLUDING GPM WITH INLET AND OUTLET TEMPERATURE AND PRESSURE READINGS (WHERE APPLICABLE). MAKE AND MODEL NUMBERS OF ALL AIR DISTRIBUTION EQUIPMENT. FINAL BALANCED AIR VOLUMES AT ALL OUTLETS (INCLUDING RETURNS WHERE DUCTED). INDEXED PLAN WITH DIFFUSER AND RETURN LOCATIONS. 1. A. PRESSURE /TEMPERATURE TEST PLUGS ( PETE'S PLUG) - 1/4 INCH NPT FITTINGS TO RECEIVE EITHER A TEMPERATURE OR PRESSURE PROBE, 1/8 INCH O.D. FITTING AND CAPS SHALL BE BRASS WITH VALVE CORE OF NORDEL, RATED AT 400 PSIG, 0'F TO 200'F. B. STRAINERS - 'Y' PATTERN STRAINERS, 125 PSIG, CAST IRON BODY WITH PERFORATED STAINLESS STEEL SCREEN, THREADED FOR 2 INCHES AND SMALLER, FLANGED FOR 2 -1/2 INCHES AND LARGER. SCREEN OPENING SIZE AT 0.033 INCH FOR HEATING AND 1/8 INCH FOR CHILLED OR CONDENSER WATER. PROVIDE WITH BLOWDOWN VALVE WITH HOSE END FITTING. C. THERMOMETERS - DIE CAST ALUMINUM, 9' INDUSTRIAL MERCURY THERMOMETER, FULLY ADJUSTABLE WITH CLEAR ACRYLIC WINDOW AND BRASS SEPARABLE SOCKET. D. MANUAL AIR VENTS - 1/8" COIN-OPiURATED VENT. PROVIDE AN AIR CHAMBER CONSISTING OF A 3/4' NIPPLE AND BUSHINGS. A. INSTALL WATER MAINS WITHOUT PITCH. USE ECCENTRIC REDUCING COUPLINGS AT CHANGES IN SIZE WITH THE TOP OF PIPES AT SALE ELEVATION. MAKE CHANGES IN DIRECTION WITH FITTINGS. B. BRANCHES TO UNITS BELOW MAINS TO BE TAKEN FROM BOTTOM OF MAINS AT A 45 DEGREE ANGLE, PITCH DOWNWARD TOWARD UNITS. BRANCHES TO UNITS ABOVE MAINS TO BE TAKEN FROM TOP OF MAINS AT A 45 DEGREE ANGLE PITCHED UPWARD TOWARDS UNITS. PITCH NOT LESS THAN 1" TO 10 FEET. C. HANGERS SHALL BE SIZED AND INSTALLED FOR THE OUTSIDE DIAMETER OF THE INSULATED PIPE. INSTALL 6' LONG SPLIT CIRCLE GALVANIZED SADDLE BETWEEN THE HANGER AND PIPE INSULATION. D. HANGERS AND PIPING OF DISSIMILAR METALS SHALL BE DIELECTRICALLY SEPARATED FROM ONE ANOTHER. E. SEE PLANS FOR APPLICABLE DETAILS. F. ALL PRESSURE PIPING SYSTEMS INSTALLED SHALL CONFORM TO THE REQUIREMENTS OF THE STATE PIPING AND WELDING 00DES. G. INSTALL VALVES AT LOW POINTS FOR DRAINING EACH SYSTEM AND INSTALL MANUAL VENTS AT ALL HIGH POINTS OF EQUIPMENT AND PIPING IN THE SYSTEM TO PROPERLY REMOVE ENTRAPPED AIR. A. ALL HYDRONIC PIPING FOR CHILLED WATER AND /OR HEATING WATER, VALVES, FITTINGS, AND ACCESSORIES SHALL BE INSULATED. FOR PIPE SIZES UP TO 2 INCHES, INSULATE WITH 1 INCH THICK (K=0.23 0 75'F FIBERGLASS INSULATION WITH ALL SERVICE JACKET AND VAPOR BARRIER. FOR PIPE SIZES 2 -1/2 INCHES AND LARGER, INSULATE WITH 1 -1/2 INCH THICK (K4.23 0 75'F) FIBERGLASS INSULATION WITH ALL SERVICE JACKET AND VAPOR BARRIER. B. INSULATION AT ALL HANGERS FOR PIPING 2 -1/2 INCHES AND LARGER SHALL BE HARD AND NON - COMPRESSIBLE. C. ALL INSULATION SHALL HAVE A FLAME SPREAD RATING OF NOT MORE THAN 25 AND A SMOKE DEVELOPED RATING OF NO HIGHER THAT 50 TO CONFORM WITH THE REQUIREMENTS OF THE NFPA. PROVIDE A COMPLETE REFRIGERANT PIPING SYSTEM BETWEEN INDOOR FAN UNIT AND OUTDOOR CONDENSING UNITS. IF APPLICABLE. PROVIDE OIL. REFRIGC CHARGE AND TEST SYSTEM. REFER TO PLANS TO DETERMINE IF A REFRIG PIPING SYSTEM IS REQUIRED. TENANT. B. C. D. E. F. G. H. J. K. AS L. REPORT SHALL INCLUDE VAV BOX AIRFLOW SENSOR DIFFERENTIAL PRESSURE READING AT MAX. AND MIN. COOLING. 5. ALL CONTROL SEQUENCES SHALL BE TESTED (INTERLOCKED EQUIPMENT, SMOKE DETECTORS, SMOKE EVACUATION, ECONOMIZER, ETC.) AND OPERATING STATUS RECORDED IN THE REPORT. 6. THREE COPIES OF THE BALANCE REPORT SHALL BE SUBMITTED THROUGH THE GENERAL CONTRACTOR TO THE TENANT'S CONSTRUCTION MANAGER FOR APPROVAL. 7. THE BALANCING CONTRACTOR SHALL PERFORM ALL APPLICABLE TESTING AND BALANCING FUNCTIONS REQUIRED FOR THE SYSTEM DESIGNED IN THESE DRAWINGS. THE BALANCING CONTRACTOR SHALL RECHECK ANY ITEMS THAT THE TENANT DEEMS NECESSARY AT NO ADDITIONAL COST TO THE TENANT. 8. FINAL BALANCE REPORT SHALL BE INCLUDED IN THE OPERATION & MAINTENANCE MANUALS. NAL HVAC INSPECTIONS ASIDE FROM NORMAL INTERIM INSPECTIONS OF WORK IN PLACE, THE TENANT SHALL HAVE THE RIGHT TO AN INDEPENDENT HVAC CONTRACTOR INSPECT THE FINISHED HVAC INSTALLATION UPON COMPLETION FOR COMPLIANCE WITH THE PLANS, SPECIFICATIONS, AND CODES. THE INSTALLING CONTRACTOR WILL BE RESPONSIBLE TO BRING ALL ITEMS REPORTED BY THE INDEPENDENT HVAC CONTRACTOR UP TO PLANS AND SPECIFICATION REQUIREMENTS AT NO COST TO TENANT. Protect Design 4 Drawings Origins' Prototype Design 22271 Jencen ArthTteclnre 2006 Jensen ,4rdNteotnra Emphoe& On rxcetlance M- Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 PHONE 614.818.2323 FAX 614.818.2337 WEB www.m- corporations.com CODE COMPLIANCE APPROVED JUL O 1 2008 City Of Tukwila ' BUILDIN DIVISION RECEIVED JUN 242008 PERMIT CENTER E,HC 5K1 A R ©lJ L D LI E IJ J IE H TOOL DEMO MO Mae AVENUE ©L ? MO, ©ll© 44116 Pl! ll ©NINEB 216281.011311 �Q D 216.781.01S4 LO r N NI J CC 0 I z JUN 1 9 20:13 m al P V s.. ocov.. co 4 5 0 ) a a) CO 0 0 CD 0) r r M3 IRIEvDSDONS MESA& SPECIFICATION L 1. GENERAL HVAC NOTES GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR DEMOLITION AND REMOVAL OF EXISTING DUCTWORK, DIFFUSERS, GRILLES, CONTROLS, ETC., AS REQUIRED TO FACILITATE NEW INSTALLATIONS. 2. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF ALL TRADES, LANDLORD REQUIREMENTS, CEILING HEIGHTS AND EXISTING STRUCTURAL CONDITIONS PRIOR TO FABRICATION OF ANY DUCTWORK OR ORDERING OF ANY EQUIPMENT. 3. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH ALL FEDERAL, STATE AND LOCAL CODES AND ORDINANCES. 4. FURNISH ALL LABOR, MATERIALS, TOOLS, INCIDENTALS AND DETAILS NECESSARY TO PROVIDE A COMPLETE HEATING, VENTILATING, AIR CONDITIONING SYSTEM. INCLUDE ANY LABOR AND MATERIAL NOT SPECIFICALLY MENTIONED, BUT NECESSARY TO PROVIDE A COMPLETE AND OPERATING SYSTEM. ALL WORK SHALL BE INSTALLED IN A PROFESSIONAL MANNER AND SHALL MEET ALL THE REQUIREMENTS OF THE STATE BUILDING CODE, CITY BUILDING CODE, SAFETY AND HEALTH CODES, NFPA CODES AND ALL OTHER APPLICABLE CODES AND REQUIREMENTS. ALL COSTS FOR SAID REQUIREMENTS SHALL BE INCLUDED IN THIS CONTRACTORS BID PRICE. 5. THIS CONTRACTOR SHALL SECURE AND PAY FOR ALL REQUIRED PERMITS AND INSPECTIONS AND PERFORM ALL TESTS CALLED FOR OR REQUIRED AS A PART OF HIS WORK. FURNISHED APPROVED CERTIFICATE OF FINAL INSPECTION, AND TURN OVER TO OWNER AT COMPLETION OF PROJECT. 6. MECHANICAL PLANS ARE DIAGRAMMATIC, NOT SHOWING EVERY ITEM IN EXACT LOCATION OR DETAIL. MEASUREMENTS AND LOCATIONS MUST BE FIELD VERIFIED AND COORDINATED WITH ARCHITECTURAL, HVAC, FIRE PROTECTION, STRUCTURAL, ELECTRICAL AND OTHER BUILDING DRAWINGS. 7. MECHANICAL CONTRACTOR TO PROVIDE TENANT WITH AS-BUILT DRAWINGS, ALL EQUIPMENT SHOP DRAWINGS, INFORMATION ON THERMOSTATS, CONTROL WIRING DIAGRAMS AND OTHER PERTINENT INFORMATION AT COMPLETION OF PROJECT. 8. CONTRACTOR SHALL VERIFY ALL EXISTING SITE CONDITIONS PRIOR TO BID AND INCLUDE IN BID ALL COSTS TO MAKE FIELD COORDINATION AND ADJUSTMENT TO DUCTWORK FOR FIT INTO EXISTING STRUCTURE. CONTRACTOR SHALL VERIFY AND FIELD COORDINATE FINAL LOCATION OF MECHANICAL EQUIPMENT. 9. NEW DUCTS USED TO CONVEY THE CONDITIONED AIR SUPPLY AND VENTILATION AIR ARE TO BE MADE OF CONTINUOUS SHEET METAL. 10. DUCT LININGS (THERMAL AND ACOUSTICAL), VIBRATION ISOLATION CONNECTORS, FLEXIBLE DUCT CONNECTORS, AND DUCT TYPE TO BE APPROVED BY CODE AND LANDLORD. 11. ALL RECTANGULAR RETURN AIR, AND SUPPLY AIR DUCTWORK SHALL BE LINED WITH 1" THICK ACOUSTICAL LINER LINED DUCTWORK DOES NOT REQUIRE EXTERIOR INSULATION. DUCT DIMENSIONS SHOWN ARE INSIDE NET DIMENSIONS, ADD TO SHEET METAL SIZE FOR INSULATION. IN GENERAL, DUCTWORK TIGHT TO UNDERSIDE OF STRUCTURE UNLESS OTHERWISE NOTED OR REQUIRED BY FIELD CONDITIONS. COORDINATE EXACT MOUNTING HEIGHT IN FIELD WITH GENERAL CONTRACTOR. ROUND RIGID SUPPLY, RETURN, ALL RELIEF AIR AND ALL OUTSIDE AIR DUCTS SHALL BE EXTERNALLY INSULATED WITH 1" THICK, 1.5 LBS. DENSITY FOIL FACED FIBERGLASS INSULATION. ROUND DUCTWORK IN CONDITIONED SPACE DOES NOT REQUIRE INSULATION UNLESS OTHERWISE NOTED. 12. ALL DUCTWORK SHALL BE SHEET METAL FABRICATED IN ACCORDANCE WITH ASHRAE GUIDE AND SMACNA MANUAL LATEST EDITIONS. 13. ALL BRANCH TAKE -OFFS SHALL BE PROVIDED WITH MANUAL BALANCING DAMPERS. 14. FLEXIBLE INSULATED DUCTS SHALL BE MAXIMUM 5' -0" LONG AND SHALL MEET INSTALLATION AND MATERIAL REQUIREMENTS OF LOCAL CODES. 15. THE MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE TEMPERATURE CONTROL SYSTEM TO INCLUDE: PANELS, MODULES, RELAYS, WIRING, THERMOSTATS, SENSORS, DAMPERS, ACTUATORS AND ALL MISCELLANEOUS ITEMS AS REQUIRED TO FULFILL THE DESIGN INTENT AS INDICATED ON THE PLANS AND IN THE CODED NOTES. 16. ALL TEMPERATURE CONTROLS, FIRE ALARM COMPONENTS, EQUIPMENT NAMEPLATES, LABELS, OR COLOR CODED COMPONENTS SHALL BE MASKED DURING PAINTING TO PREVENT DAMAGE FROM OVER - SPRAY OR OBSCURING INFORMATION. 17_ ALL LOW VOLTAGE WIRING AND CONDUIT REQUIRED FOR MECHANICAL EQUIPMENT SHALL BE FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING WITH ELECTRICAL CONTRACTOR ALL WIRING AND CONDUIT REQUIRED FOR EQUIPMENT OPERATION AND CONTROL. 18. EXISTING SPRINKLER SYSTEM TO BE MODIFIED AS REQUIRED FOR COVERAGE TO MEET LOCAL CODES AND LANDLORD REQUIREMENTS APPROVAL ALSO REQUIRED BY LANDLORD'S INSURER 19. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE THAT THE MECHANICAL EQUIPMENT COMPONENTS ARE INSTALLED AT LOCATIONS AND ELEVATIONS WHICH MAKE THEM READILY ACCESSIBLE FOR ROUTINE MAINTENANCE WITHOUT REQUIRING ANY EXTRAORDINARY MEASURES. 0 0 a 0 0 0 0 a rti k ?"* MECHANICAL CODED NOTES VERIFY ALL CONDITIONS IN THE FIELD PRIOR TO BIDDING REVISIONS No changes shall be made to thA scopa of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. GENERAL CONTRACTOR TO UNDER CUT DOOR, 1" FOR AIR FLOW. L.L.'S EXIST. TOILET EXHAUST DUCT ioq THE MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL A PROGRAMMABLE THERMOSTAT AT 4 FT. ABOVE FINISHED FLOOR. COORDINATE EXACT LOCATION WITH TENANT. THERMOSTAT MUST BE FULLY COMPATIBLE WITH HVAC UNIT USED FOR PROJECT, COORDINATE EXACT MODEL AND TYPE WITH UNIT MANUFACTURER. THERMOSTAT TO HAVE LOCKING ACRYLIC COVER. PROVIDE NEW CONNECTION TO LANDLORD'S EXISTING MEDIUM PRESSURE DUCTWORK. VERIFY THE EXACT LOCATION OF THE LANDLORD'S DUCTWORK IN THE FIELD PRIOR TO BIDDING. TOILET EXHAUST FAN COMPLETE WITH INTEGRAL BACKDRAFT DAMPER SHALL BE FURNISHED AND INSTALLED BY THE MECHANICAL CONTRACTOR. EXHAUST CAPACITY SHALL BE 100 CFM UP TO 0.625" S.P.. EXHAUST TO BE CONNECTED TO THE LANDLORD'S CENTRAL EXHAUST DUCT. REFER TO PLANS FOR FURTHER INFORMATION. FAN POWERED VARIABLE - AIR - VOLUME (VAV) PARALLEL BOX FURNISHED AND INSTALLED BY THE CONTRACTOR. UNIT IS SUSPENDED FROM THE STRUCTURE WITH IN -LINE COMBINATION RUBBER AND SPRING VIBRATION ISOLATORS FURNISHED AND INSTALLED BY THE GENERAL CONTRACTOR. EXISTING DUCTWORK TO REMAIN. TYPE, SIZE AND ELEVATION ARE AS NOTED. TENANT SHALL FURNISH /MAINTAIN A 6" MINIMUM CLEAR OPEN HEIGHT ABOVE COMMON TENANT DEMISING WALLS AND BELOW STRUCTURE, OR OTHER BUILDING ELEMENTS (DUCTS, FOR EXAMPLE) THAT WOULD ALLOW THE PASSAGE OF RETURN AIR BACK TO THE LANDLORD'S HVAC UNIT. REFER TO THE LANDLORD'S DETAIL FOR FURTHER INSTRUCTIONS. SMOKE DETECTOR FURNISHED BY ELECTRICAL CONTRACTOR AND INSTALLED BY MECHANICAL CONTRACTOR. SMOKE DETECTOR MUST BE IN AN ACCESSIBLE LOCATION IN AIR DUCT. THE ELECTRICAL CONTRACTOR TO WIRE THE SHUT DOWN SEQUENCE OF THE HVAC UNIT UPON SENSING SMOKE, AND TO INTERFACE 'MTh THE MALL'S FIRE /SMOKE ALARM SYSTEM. REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION. 20" X 20" CEILING ACCESS PANEL BY GENERAL CONTRACTOR. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN AND ARCHITECTURAL SPECIFICATIONS FOR FURTHER INFORMATION. ACCESS PANEL TO BE USED FOR ACCESS TO EQUIPMENT LOCATED ABOVE THE CEILING. THIS CONTRACTOR SHALL BE RESPONSIBLE TO ENSURE THAT A MINIMUM UNOBSTRUCTED FREE AREA OF 3 -FEET VERTICALLY AND 2 -FEET HORIZONTALLY IN ALL DIRECTIONS AROUND EQUIPMENT IS MAINTAINED TO ALLOW FOR INSTALLATION AND MAINTENANCE OF EQUIPMENT. SEPARATE PERMIT REQUIRED FOR i ethank aI Er_ Electrical Ln lumbing G as Piping City of Tukwila BUILDING DIVISION L.L.'S EXIST. SUPPLY AIR DUCT MECHANICAL PLAN 1/4"- -v-o" Mar review approval 1s subject to errors and o sk n Approval of construction dusts does not autho l;. the violation of any adopted code or ordnance. Rer.; af approved Field Copy and conditions is aCknOwIcdgi By _��1_ Date: City of Tukwila BUILDING DIVISION RE VISIONS No r h- 1 - e. :a3 ;^ ;o the s oPA n y , ;. '+,:It foilt prior approval of Tukwila Building Division. N OTE: Revisions will require a new plan submittal and may include additional plan review fees. FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. SYMBOL LEGEND SYMBOL 1 T HSW LSW M.G. E.C. 1 DESCRIPTION SUPPLY AIR DIFFUSER SHADING DENOTES BLANK -OFF DUCT MOUNTED DIFFUSER SUPPLY OR RETURN AIR LINEAR DIFFUSER RETURN AIR GRILLE OR DUCT SUPPLY AIR DUCT RISE SIMILAR FOR RETURN AIR SUPPLY AIR DUCT DROP SIMILAR FOR RETURN AIR HIGH SIDE WALL LOW SIDE WALL MECHANICAL CONTRACTOR ELECTRICAL CONTRACTOR DESCRIPTION ROOF MOUNTED EQUIPMENT AS NOTED CEILING EXHAUST FAN T- DENOTES THERMOSTAT S- DENOTES SENSOR TURNING VANES DUCT TRANSITIONS F.D. - FIRE DAMPER DUCT SMOKE DETECTOR RECEIVE MAY. 14ZC PERMIT DEN BRANCH DUCT WITH SPIN -IN FITTING AND VOLUME DAMPER SYMBOL D ER Empharir On Excellence M• Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 PHONE 614.818.2323 FAX 614.818.2337 WEB www.m— corporations.com SEAL. DATE: PROJECT: D ennis T Mitchell NCARB, AIA Architect 6031 1 -20 WEST, SUITE 260 ARLINGTON TX 76017 817 - 265 -2415 FAX 617- 483 -7377 DTMArchitectWITMArchitect.com TIME CIDER& CONTRACTOR AND /OR ALL SUBCONTRACTORS !DORKING FROM T4E51= PLANS AND SF'ECIFICATIC S ARE NOT 0 SCALE SUCH INFORMATION BUT TO CONTACT THE AkG- IITECT H18 REFRESENTATIVE REGARDM MEASUREMENTS, F SUCH ` MEASIIREh1EM5 PO NOT APPEAR CORRECT, ADD UP FROPERLY OR SCALE CORECTLY TO THE INDICATED SIZE APR 2 8 2008 viramin WORLD PROJECT LOCATION: VITAMIN WORLD 1119 SOUTNCENTER MALL TUKWILA, WA 98188 TOTAL AREA: SHEET TITLE: DRAWN BY: 900 SF. MECHANICAL PLAN PROJECT NO. 0813048 SCALE: AS NOTED DATE: 4/1/2008 LJ REVIEWED 5Y: TEL SHEET NO. M - 1 —1 MECHANICAL /PLUMBING RESPONSIBILITY SCHEDULE ITEM FURNISHED BY INSTALLED BY REUSE EXISTING N/A REMARKS TENANT LANDLORD CONTR. LANDLORD CONTR. AIR HANDLING UNITS CLG. OTHER STEEL ALUM. SD -1 OMNS • 10 "0 STRUCTURAL SUPPORTS FOR AHU AS REQUIRED VAV -1 • 3 A 810 B • SD -2 AHU MIXING BOX AND MIXING BOX MOTOR OPERATED DAMPERS 24 "x24" 10 "O 0 - • - • AHU MIXING BOX MOTOR OPERATED DAMPER ACTUATOR • CONDENSING UNITS RG -1 TITUS 355RL 0 22 "x22" CURB AND /OR STRUCTURAL SUPPORTS FOR COND. UNITS AS REQUIRED 0 A . B • RG -2 ROOF TOP UNITS 24 "x12" 22 "x10" 0 0 • ROOF CURB AND /OR CURB ADAPTER FOR RTU AS REQUIRED • STRUCTURAL SUPPORTS FOR RTU AS REQUIRED. • V.A.V. BOXES • 0 SEE CODED NOTES DIFFUSERS AND GRILLES • • DIFFUSERS /GRILLES FIRE DAMPERS 0 WALL ARE DAMPERS AND /OR COMBINATION SMOKE /FIRE DAMPERS • LOW PRESSURE DUCTWORK 0 • HIGH /MEDIUM PRESSURE DUCTWORK • 0 SEE CODED NOTES TEMPERATURE CONTROL SYSTEM 0 0 SEE CODED NOTES REUEF AIR /MAKE UP AIR MOTOR OPERATED DAMPERS • REUEF AIR /MAKE UP AIR MOTOR OPERATED DAMPER ACUATORS • SMOKE DETECTOR(S) IN RETURN AND /OR SUPPLY AIR DUCT • SEE CODED NOTES ZONE DAMPERS 0 DUCT HEATER(S) 0 UNIT /BASEBOARD HEATER(S) • RETURN AIR FAN 0 OUTSIDE AIR INTAKE HOOD /FAN 0 RELIEF AIR FAN OR HOOD 0 TOILET EXHAUST FAN(S) 0 • SEE CODED NOTES TOILET EXHAUST DUCTWORK WALL OR ROOF CAP 0 • SEE CODED NOTES AIR BALANCE REPORT • AABC OR NEBB CERTIFIED AS -BUILT DRAWINGS 0 PLUMBING FIXTURES 0 0 SAN, CW, HW, PIPING AND WATER METER • • SPRINKLER PIPING AND HEADS 0 0 REWORK PIPING IF POSSIBLE FIRE EXTINGUISHERS 0 0 BY G.C. IF NONE EXISTING GENERAL NOTE A "QUICK" REFERENCE. ALL ITEMS LISTED HERE ARE SPECIFIED AND DETAILED ENCOUNTERS ITEMS THAT ARE CONTRADICTORY THEN IT IS HIS CONSTRUCTION MANAGER SO THAT THESE ITEMS CAN BE CLARIFIED THIS SCHEDULE IS INTENDED AS ON THESE DRAWINGS. IF THE CONTRACTOR RESPONSIBILITY TO INFORM TENANT'S FOR THE CONTRACTOR. AIR DEVICE SCHEDULE NOTES : 1. SYMBOL KEY - 4. VOLUME DAMPER - FIRST LETTER: S- SUPPLY R- RETURN E -EXH T- TRANSFER FACTORY FURNISHED. OPPOSED BLADE OR BUTTERFLY SECOND LETTER: D- DIFFUSER R- REGISTER G- GRILLE WHERE AVAILABLE. ADJUSTABLE FROM FACE. 2.PROVIDE OPTIOAL DIRECTIONAL BLOW FEATURE FOR 5. BORDER STYLE - OTHER THAN 4 -WAY. "A" SURFACE MOUNTED 3. FINISH- "B" LAY -IN, PROVIDE WITH PLASTER FRAME FOR DRYWALL CEIUNG MOUNTING. " A " WHITE. "C" LAY -IN FRAME FOR T -BAR CEIUNG. "B" WHITE - G.C. TO FIELD PAINT TO MATCH CEIUNG OR WALL WITH ENAMEL FINISH. 6. PROVIDE BOOT FOR DUCT MOUNTING. SYMBOL (1)(2) MANUFACTURER/ CATALOG NUMBER NOMINAL SIZE MOUNTING MATERIAL FINISH (3) DER. (4) BORDER (5) REMARKS MOD. NECK CLG. OTHER STEEL ALUM. SD -1 OMNS 24 "x24" 10 "0 0 VAV -1 • 3 A 810 B 33 SD -2 TMSS 24 "x24" 10 "O 0 - • - A C RG -1 TITUS 355RL 24 "x24" 22 "x22" 0 0 A . B RG -2 355RL 24 "x12" 22 "x10" 0 0 A C VAV BOX SCHEDULE TAG MODEL BOX SIZE PRIMARY AIR INLET SIZE CO) BOX PRIMARY CFM RADIATED MAXIMUM NC FAN (PARALLEL) ELECTRIC HEATING COIL REMARKS DESIGN OPERATION CFM E.S.P. (IN WC) HP VOLTS PHASE KW STEPS EAT (•F) LAT (e F) VOLTS PHASE DESIGN COOLING DESIGN HEATING VAV -1 45M 3 8 "0 810 - 33 810 1 1/10 208 3 - - - - - - L Design Parameters: City Name Seattle IAP Location Washington Latitude 47.5 Deg. Longitude 122.3 Deg. Elevation 449.0 ft Summer Design Dry-Bulb 85.0 °F Summer Coincident Wet -Bulb 65.0 °F Summer Daily Range 18.3 °F Winter Design Dry-Bulb 23.0 °F Winter Design Wet -Bulb 19.2 °F Atmospheric Cleamess Number 1.05 Average Ground Reflectance 0.20 Soil Conductivity 0.800 BTU/(hr-ft-°F) Local Time Zone (GMT +/- N hours) 8.0 hours Consider Daylight Savings Time Yes Daylight Savings Begins April, 1 Daylight Savings Ends October, 31 Simulation Weather Data noneN /A Current Data is 2001 ASHRAE Handbook Design Cooling Months January to December Air System Information Air System Name SALESINONSALES Equipment Class PKG ROOF Air System Type VAV Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible Toad Space CFM Individual peak space Toads Central Cooling Coil Sizing Data Total coil Toad 1.3 Tons Total coil load 15.6 MBH Sensible coil load 13.1 MBH Coil CFM at Jan 2100 658 CFM Max block CFM at Jan 2100 801 CFM Sum of peak zone CFM 801 CFM Sensible heat ratio 0.841 ft 693.9 BTU /(hr - ft 2 ) 17.3 Water flow @ 10.0 °F rise N/A Preheat Coil Sizing Data No heating coil loads occured during this calculation. Supply Fan Sizing Data Actual max CFM at Jan 2100 801 CFM Standard CFM 788 CFM Actual max CFM/11 0.89 CFM/ft Outdoor Ventilation Air Data Design airflow CFM 0 CFM CFM/ft 0.00 CFM/ft Number of zones 2 Floor Area 900.0 ft Location Seattle IAP, Washington Calculation Months Jan to Dec Sizing Data Calculated Load occurs at Jan 2100 OADB /WB 58.2 /50.4 °F Entering DB / WB 76.7164.8 °F Leaving DB / WB 58.0 / 56.9 °F Coil ADP 55.9 °F Bypass Factor 0.100 Resulting RH 56 % Design supply temp. 58.0 °F Zone T -stat Check 2 of 2 OK Max zone temperature deviation 0.0 °F Fan motor BHP 0.00 BHP Fan motor kW 0.00 kW Fan static 0.00 in wg CFM /person 0.00 CFM /person Air System Information Air System Name SALESINON -SALES Equipment Class PKG ROOF Air System Type VAV Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible Toad Space CFM Individual peak space Toads Zone Sizing Data Zone Name Zone 1 Zone 2 Space Loads and Airflows Zone Name/ Space Name Zone 1 SALES Zone 2 NON - SALES Maximum Cooling Sensible (MBH) 8.5 4.1 Cooling Sensible Mult (MBH) 1 1 Design Air Flow (CFM) 573 228 Time of Load 8.5 Jan 2100 4.1 Jan 2100 Number of zones 2 Floor Area 900.0 ft Location Seattle IAP, Washington Calculation Months Jan to Dec Sizing Data Calculated Minimum Air Flow (CFM) 6 2 Air Flow (CFM) 573 228 Time of Peak Load Jan 2100 Jan 2100 Heating Load (MBH) Maximum Heating Load (MBH) 0.0 0.0 0.0 740.0 0.0 Zone Floor Area () 740.0 160.0 Floor Area Space (ft CFM /ft 160.0 0.77 1.42 Zone CFM /ft' 0.77 1.42 DESIGN COOLING COOLING DATA AT Jan 2100 COOLING OA DB / WB 58.2 °F 1 50.4 °F ZONE LOADS Details Window & Skylight Sola r Loads 0 ft Wall Transmission 0 ft Roof Transmission 0 f1 Window Transmission 0 ft Skylight Transmission 0 ft Door Loads Floor Transmission 900 ft Partitions Ceiling 0 ft Overhead Lighting 996 W Task Lighting 784 W Electric Equipment 1596 W People 11 Infiltration - Miscellaneous - Safety Factor 5% / 5% » Total Zone Loads - Zone Conditioning - Plenum Wall Load 0% Plenum Roof Load 70% Plenum Lighting Load 30% Return Fan Load 658 CFM Ventilation Load 0 CFM Supply Fan Load 658 CFM Space Fan Coil Fans Duct Heat Gain / Loss as Total System Loads Central Cooling Coil Preheat Coil Terminal Reheat Coils » Total Conditioning Key: Positive values are clg loads Negative values are htg Toads 0f1 0 ft Sensible ( BTU/hr) 0 0 0 0 0 0 0 0 0 2160 2359 5159 2365 0 0 602 12645 12075 0 0 1020 0 0 0 0 0 13094 13094 0 0 13094 Latent (BTU /hr) 2351 0 0 118 2468 2468 0 2468 2471 DESIGN HEATING HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F /19.2 °F Sensible Details ( BTU/hr) 0 ft 0 ft 0 0 ft 0 0 ft 0 ft 0 ft 900 ft 0 ft 0 ft2 0 0 0 0 5% 0 0 0 8 CFM 0 CFM 8 CFM 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -96 0 0 0 0 0 0 0 0% 0 -96 -96 0 0 2471 -96 Positive values are htg loads Negative values are clg loads Latent (BTU/hr) 0 0 0 0 0 0 0 0 0 0 NOTES: VAV BOX (SINGLE OR DUAL DUCT). SEE PLANS AND SCHEDULE FOR TYPES & SIZES. TRANSITION (AS REQUIRED) MEDIUM PRESSURE FLEXIBLE PRIMARY AIR INLET (MAXIMUM 5' -0" LENGTH). A MINIMUM STATIC PRESSURE DROP ACROSS THE VAV BOX FOR PROPER OPERATION SHALL BE BETWEEN 0.1" AND 0.15", AS TESTED PER ARI 880. ALL DUCT LINER TRANSVERSE EDGES TO BE COATED W/ ADHESIVE IN ACCORDANCE W/ SMACNA STANDARDS (TYP.) N TS PRIMARY AIR INLET FASTEN W/ MIN. (3) SHT. MTL. SCREWS, SEAL W/ DUCT TAPE AND MASTIC VOLUME DAMPER L TAPE DOWN EXTERNAL INSULATION ROUND RIGID DUCT - 1" WRAPPED INSULATION TYP. ROUND DUCT TAKE -OFF SCHEMATIC TO S.A. MAIN INSULATED ROUND DUCT FLEXIBLE CONNECTION (MAX. 5 FT.) THERMAL INSULATING BLANKET WHERE REQUIRED. SUPPLY AIR DIFFUSER - MAIN DUCT 1 DIFFUSER MOUNTING SCHEMATIC NTS FLEXIBLE CONNECTION NIT OUTLET MAINTAIN 18" CLEARANCE FOR CONTROL ACCESS. VERIFY CONTROLS LOCATION WITH MANUFACTURER. VAV BOX SCHEMATIC r NTS 1" ACOUSTICAL UN NOTE: CLOSELY COORDINATE LOCATIONS OF ALL BOXES WITH STRUCTURE, CEILINGS, LIGHTS, PIPING, AND CONDUITS. PROVIDE FULL ACCESSIBILITY TO UNIT AND CONTROLS. FLANGED AND GASKETED JOINT OR DUCT CONNECTION AND RE- INFORCEMENT IN ACCORDANCE W/ SMACNA 2" W.G. CLASS, SEAL NON- GASKETED TRANS- VERSE JOINTS IN ACCORDANCE W/ SMACNA CLASS "C" (TYP.) AIR FLOW 1 - CONICAL OR BELLMOUTH SPIN- IN FITTING, SEAL AIRTIGHT W/ MASTIC STRAP CLAMP (TYPICAL) FIRE DAMPER WHERE REQUIRED k s ** - - DRYWALL CEILING PLASTER FRAME BOX SUPPORT PER SPECIFICATIONS & MANUFACTURER'S RECOMMENDATIONS. SUPPORTS SHALL NOT INTERFERE WITH ACCESS PANELS. TRANSITION (AS REQUIRED) SIZED PER PLANS RECTANGULAR LINED DISCHARGE DUCT SAME SIZE AS COIL OUTLET. (MINIMUM 5' -O" LENGTH) RECEIVEn MAY 14 2008 PERMIT CENTE ANNOON" T Mitchell NCARB, AIA Architect 6031 1 -20 WEST, SUITE 260 ARLINGTON TX 76017 817 - 265 -2415 FAX 817 - 483 -7377 DTMArchitect®OTMArchitect.com Ernphaem an Excellence M•Retail Engineering, Inc_ 750 Brooksedge Blvd. Westerville, Ohio 43081 PHONE 614.818.2323 FAX 614.818.2337 WEB www.m- corporations.com SEAL: 0 7 1 1 / 0 ExPIRES 9 1 DATE: APR 2 8 2008 TIE GENERAL CGNIR4CTOR AND /OR ALL SUBCONTRACTORS IWRK trig FROM t1 E$E PLANS AND SPECIFICATIONS ARE NOT To SCALE SUC1•I lisFORMATION EUT TO CONTACT THE ARCI- IITECT OR MIS REFRESENTATIVE REGARDING MEASUREMENTS, IF SUG-I MEASUREMENTS DO NOT APPEAR CORRECT, ADD UP PROPERLY OR SCALE CORRECTLY To THE INDICATED SIZE. PROJECT: virAmin WORLD PROJECT LOCATION: VITAMIN WORLD 1119 SOUTHCENTER MALL TUKWILA, WA 98188 TOTAL AREA: 91 D0 SF. SHEET TITLE: MECHANICAL SCHEDULES AND SCHEMATICS PROJECT NO. 0813048 SCALE: AS NOTED DATE: 4/1/2008 DRAUJN BY: LJ REVIEWED BY: TEL SHEET NO. M=2 1 L DIVISION 15 -MECHANICAL SECTION 15000 MECHANICAL GENERAL PROVISIONS A. GENERAL CONDITIONS 1. DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND ALL OTHER SPECIFICATION SECTIONS ARE A PART OF THIS CONTRACT AND APPLY TO THIS AND THE OTHER SECTIONS OF DIVISION 15. 2. THE CONTRACTOR FOR THIS WORK IS REQUIRED TO READ THE ENTIRE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL OTHER TRADES. 3. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING HIS SUBCONTRACTORS WITH A FULL SET OF BID SET DOCUMENTS (INCLUDING SPECIFICATIONS) AND THE COORDINATION OF HIS WORK AND INSPECTIONS AND THE WORK AND INSPECTIONS OF HIS SUBCONTRACTORS WITH ALL OTHER TRADES ON SITE CONFORMING TO THE GENERAL CONTRACTOR'S TIME SCHEDULE. 4. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTING HIS BID TO DETERMINE CONDITIONS AFFECTING THE WORK. BIDS SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS AND ANY MODIFICATIONS WHICH ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS. FAILURE TO VISIT THE SITE DOES NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY IN PERFORMANCE OF WORK. 5. WHEN USED, THE TERM 'PROVIDED BY CONTRACTOR' SHALL BE INTERPRETED AS MEANING "FURNISHED AND INSTALLED" WITH THE EXCEPTION WHERE ITEMS ARE "PROVIDED BY TENANT' WHICH MEANS 'FURNISHED ONLY (INSTALLED BY CONTRACTOR). EXCEPT AS SPECIFICALLY NOTED OTHERWISE. B. GENERAL REQUIREMENTS 1. THE CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION, INCIDENTALS AND DETAILS NECESSARY TO PROVIDE A COMPLETE AND FULLY FUNCTIONAL MECHANICAL SYSTEM AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR. CLOSELY COORDINATE THE ENTIRE INSTALLATION WITH THE LANDLORD, AS REQUIRED. FIELD VERIFY THE EXACT TYPE, SIZE AND LOCATION, ETC. OF EXISTING PIPE AND DUCTS IN THE TENANT SPACE PRIOR TO BID. 2. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY MATERIAL OR LABOR CALLED FOR IN ONE SHALL BE PROVIDED EVEN THOUGH NOT SPECIFICALLY MENTIONED IN BOTH. ANY MATERIAL OR LABOR WHICH 15 NEITHER SHOWN ON THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS, BUT WHICH IS OBVIOUSLY NECESSARY TO COMPLETE THE WORK, AND WHICH I5 USUALLY INCLUDED IN WORK OF SIMILAR CHARACTER. SHALL BE PROVIDED AS PART OF CONTRACT. 4. ALL MECHANICAL WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING, AND REPAIRING. THE CONTRACTOR 15 RESPONSIBLE FOR PROVIDING SUFFICIENT ACCESS TO ALL EQUIPMENT FOR SERVICE. C. CODES D. LICENSES, PERMITS, INSPECTIONS & FEES 1. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LICENSES. PERMITS, INSPECTIONS, AND FEES REQUIRED OR RELATED TO HIS WORK. 2. FURNISH TO THE TENANT'S CONSTRUCTION MANAGER ALL CERTIFICATES OF INSPECTION AND FINAL INSPECTION APPROVAL AT SUBSTANTIAL COMPLETION DATE OF PROJECT. E. DRAWINGS 1. DRAWINGS (PLANS, SPECIFICATIONS, AND DETAILS) ARE DIAGRAMMATIC AND INDICATE THE GENERAL LOCATION AND INTENT OF THE MECHANICAL SYSTEMS. BECAUSE OF THE SMALL SCALE OF THE DRAWINGS, IT IS NOT POSSIBLE TO INDICATE ALL DUCT AND PIPING OFFSETS, FITTINGS AND ACCESSORIES THAT MAY BE REQUIRED. 2. THE LAYOUT SHOWN ON THE DRAWINGS I5 BASED ON A PARTICULAR MAKE OF EQUIPMENT. IF ANOTHER MAKE OF EQUIPMENT IS USED WHICH REQUIRES MODIFICATION OR CHANGE OF ANY DESCRIPTION FROM THE DRAWINGS OR SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE AS PART OF THIS WORK, FOR MAKING ALL SUCH MODIFICATIONS AND CHANGES, INCLUDING THOSE INVOLVING OTHER TRADES WITH THE COST THEREOF INCLUDED IN HIS BID. IN SUCH CASE, CONTRACTOR SHALL SUBMIT DRAWINGS AND SPECIFICATIONS PRIOR TO STARTING WORK SHOVING ALL SUCH MODIFICATIONS AND CHANGES. HIS PROPOSAL SHALL BE SUBJECT TO THE APPROVAL OF THE TENANT'S CONSTRUCTION MANAGER. F. EXISTING SHELL SPACE CONDITONS 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF THE DEMOLITION OF EXISTING MECHANCIAL WORK SHOWN ON THE MECHANCIAL DRAWINGS AND THE MECHANCIAL DEMOLITION SHOWN ON THE ARCHITECTURAL DRAWINGS. 2. THE CONTRACTOR SHALL INCLUDE, AND WILL BE HELD RESPONSIBLE FOR, THE REMOVAL OF ALL EXISTING FIRE PROTECTION, PLUMBING FIXTURES, PIPING, HVAC UNITS, REFRIGERANT RECAPTURE, EXHAUST FANS, ETC. AND ASSOCIATED ROOF CURBS NOT TO BE REUSED ON THIS PROJECT, UNLESS SPECIFICALLY NOTED OTHERWISE. CONTRACTOR MUST VERIFY WITH THE LANDLORD ALL PRESUMED ABANDONED EQUIPMENT. PIPES, DUCTWORK, AND EQUIPMENT PRIOR TO REMOVAL. ROOF CURBS SHALL BE REMOVED AND THE ROOF PATCHED UNLESS NOTED FOR REUSE OR RECONFIGURATION ON PLANS. ROOF PATCHING SHALL BE PERFORMED AT THE CONTRACTOR'S EXPENSE BY A ROOFING CONTRACTOR APPROVED BY THE LANDLORD. ALL EXTRANEOUS ITEMS IN THE SPACE OR ON THE ROOF (ABOVE THIS SPACE) NOT APPLICABLE TO THE NEW WORK OR PART OF THE LANDLORD'S OR ANOTHER TENANT'S ACTIVE SYSTEM MUST BE REMOVED AND ROOF/WALL /FLOOR PATCHED/REPAIRED TO MATCH EXISTING STRUCTURE. EXISTING ABANDONED PIPES, DUCTS, OR EQUIPMENT IN THE FLOOR, EMBEDDED IN CONCRETE, OR OTHERWISE INACCESSIBLE ARE TO BE CUT OFF AND SEALED BELOW CR WITHIN FLOOR OR WALL LEVEL WHEN THEY ARE NOT TO BE REUSED IN THIS PROJECT. IF REQUIRED BY LANDLORD OR CODES, ABANDONED PIPING AND /OR DUCTWORK MUST BE REMOVED TO POINT OF ORIGIN. CONFIRM THE EXTENT OF DEMOLITION PRIOR TO BID AND INCLUDE IN BID PROPOSAL. G. DISCREPANCIES IN DOCUMENTS 1. DRAWINGS (PLANS, SPECIFICATIONS, AND DETAILS) ARE DIAGRAMMATIC AND INDICATE THE GENERAL LOCATION AND INTENT OF THE MECHANICAL SYSTEMS. WHERE DRAWINGS, EXISTING SITE CONDITIONS, SPECIFICATIONS OR OTHER TRADES CONFLICT OR ARE UNCLEAR, ADVISE THE GENERAL CONTRACTOR IN WRITING, PRIOR TO SUBMITTAL OF BID. THE GENERAL CONTRACTOR IS RESPONSIBLE TO ADVISE THE TENANT'S CONSTRUCTION MANAGER, IN WRITING, OF VARIATIONS TO CONTRACT DOCUMENTS PRIOR TO SUBMISSION OF BID. OTHERWISE, TENANT'S CONSTRUCTION MANAGER'S INTERPRETATION OF CONTRACT DOCUMENTS OR CONDITIONS SHALL BE FINAL WITH NO ADDITIONAL COMPENSATION PERMITTED. H. TRADE NAMES AND MANUFACTURERS 1. WHERE TRADE NAMES AND MANUFACTURERS ARE USED ON THE DRAWINGS OR IN THE SPECIFICATIONS, THE EXACT EQUIPMENT SHALL BE USED AS A MINIMUM STANDARD FOR THE BASE BID. MANUFACTURERS CONSIDERED AS AN EQUAL OR BETTER IN ALL ASPECTS TO THAT SPECIFIED WILL BE SUBJECT TO APPROVAL IN WRITING BY THE TENANT'S CONSTRUCTION MANAGER PRIOR TO ACCEPTANCE. THE USE OF ANY UNAUTHORIZED EQUIPMENT SHALL BE SUBJECT TO REMOVAL AND REPLACEMENT AT THE CONTRACTOR'S EXPENSE. J. K. 3. WHERE THE DRAWINGS OR SPECIFICATIONS CALL FOR ITEMS WHICH EXCEED CODES OR THE LANDLORD'S TENANT CRITERIA, THE CONTRACTOR IS STILL RESPONSIBLE 1. FOR PROVIDING THE SYSTEM AS DESIGNED AND DESCRIBED ON THESE DRAWINGS, UNLESS SPECIFICALLY NOTED OTHERWISE. 5. THE CONTRACTOR SHALL DO ALL CUTTING, CORE DRILLING, CHASING OR CHANNELING AND PATCHING REQUIRED FOR ANY WORK UNDER THIS DIVISION. L. CUTTING SHALL HAVE PRIOR APPROVAL BY THE TENANT'S CONSTRUCTION MANAGER AND THE LANDLORD. PATCHING SHALL MATCH, FINISH OF SURROUNDING AREA. 1. ALL WORK SHALL BE PERFORMED IN A NEAT PROFESSIONAL MANNER USING GOOD ENGINEERING PRACTICES. ALL WORK SHALL CONFORM TO THE LANDLORD'S CRITERIA, THE STATE'S, COUNTY'S, CITY'S AND LOCAL CODES AND ORDINANCES, SAFETY AND HEALTH CODES, NFPA CODES, ENERGY CODES AND ALL OTHER APPLICABLE CODES AND REQUIREMENTS. THE CONTRACTOR SHALL INQUIRE M. INTO AND COMPLY WITH ALL APPLICABLE CODES, ORDINANCES, AND REGULATIONS. AFTER CONTRACT I5 ISSUED, NO ADDITIONAL COST DUE TO COOE ISSUES SHALL BE REIMBURSED BY THE TENANT TO THE CONTRACTOR. 3. ACTIVE LANDLORD OR OTHER TENANT SERVICES ENCOUNTERED IN WORK SHALL BE PROTECTED AND SUPPORTED. IF EXISTING SERVICES NOT ANTICIPATED REQUIRE RELOCATION, CONTACT THE TENANT'S CONSTRUCTION MANAGER IMMEDIATELY. P. ALL COSTS FOR REPAIR OF DAMAGES TO ACTIVE LANDLORD OR OTHER TENANT SERVICES DURING CONSTRUCTION SHALL BE PAID FOR BY THE CONTRACTOR CAUSING THE DAMAGE. 4. TIE -INS AND MODIFICATIONS TO EXISTING LANDLORD SERVICES MUST BE DONE WITH MINIMUM INTERRUPTION OF LANDLORD OPERATION AND DURING HOURS SPECIFIED BY THE LANDLORD. THE CONTRACTOR 15 RESPONSIBLE FOR CONFIRMING EXACT WORKING HOURS OF THIS WORK WITH THE LANDLORD PRIOR TO SUBMITTING HIS BID. THE CONTRACTOR SHALL INCLUDE IN HIS BID, ALL PREMIUM TIME REQUIRED TO PERFORM MODIFICATIONS DURING OTHER THAN NORMAL WORKING HOURS. ALL SUCH WORK MUST BE COORDINATED WITH THE LANDLORD. Q. SHOP DRAWINGS A. SCOPE OF WORT( 1. SUBMIT SIX COPIES OF MATERIAL LISTS AND SHOP DRAWINGS FOR ALL EQUIPMENT AND DUCT FABRICATION DRAWINGS TO THE TENANT'S CONSTRUCTION MANAGER FOR APPROVAL PRIOR TO ORDERING EQUIPMENT. SUBMISSIONS MUST BE EARLY ENOUGH TO ALLOW THE TENANT'S CONSTRUCTION MANAGER EIGHT WORKING DAYS FOR REVIEW WITHOUT CAUSING DELAYS OR CONFLICTS TO THE JOB'S PROGRESS. SUBMITTALS SHALL BE IN ACCORDANCE WITH THE GENERAL CONDITIONS USING THE MANUFACTURER'S LISTED ON THE DRAWINGS. SHOP DRAWINGS SHALL INCLUDE ALL DATA THAT PERTAINS TO THE REQUIREMENTS SET FORTH ON THE DRAWINGS AND IN THE SPECIFICATIONS. THE SUBMITTAL SHALL INCLUDE BUT NOT LIMITED TO CUTS OR CATALOGS INCLUDING DESCRIPTIVE LITERATURE AND CHARACTERISTICS OF EQUIPMENT SHALL SHOW MAJOR DIMENSIONS, ROUGHING -IN DATA, CAPACITY, CURVES, PRESSURE DROP, CODE COMPLIANCE, MOTOR AND DRIVE DATA AND ELECTRICAL DATA. OBSERVE SPECIAL INSTRUCTIONS WHEN REQUIRED. SUBMITTALS SHALL BEAR THE STAMP OF THE GENERAL AND SUB-CONTRACTOR SHOWING THAT HE HAS REVIEWED AND CONFIRMED THAT THEY ARE IN CONFORMANCE WITH THE CONTRACT DRAWINGS AND SPECIFICATIONS OR INDICATE WHERE EXCEPTIONS TAKE PLACE. LACK OF SUCH CONTRACTOR'S REVIEW AND APPROVAL WILL BE CAUSE FOR REJECTION WITHOUT REVIEW BY TENANT'S CONSTRUCTION MANAGER. ALL SHOP DRAWINGS MUST APPEAR IN THE OPERATION AND MAINTENANCE MANUALS LEFT ON SITE AT JOB COMPLETION. 2. TENANT'S CONSTRUCTION MANAGER'S REVIEW OF SHOP DRAWINGS OR SCHEDULES SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR ERRORS, OMISSIONS OR OTHER DEFICIENCIES OR DEVIATIONS IN THE SHOP DRAWING FROM THE CONTRACT DRAWINGS AND SPECIFICATIONS. RECORD DRAWINGS 2. AT COMPLETION OF THE PROJECT AND BEFORE FINAL APPROVAL, THE CONTRACTOR SHALL MAKE ANY FINAL CORRECTIONS TO DRAWINGS AND CERTIFY THE ACCURACY OF EACH PRINT BY SIGNATURE THEREON. THE DRAWINGS ARE TO BE TURNED OVER TO THE TENANT. GUARANTEE SLEEVES 1. N. HANGERS 0. ACCESS DOORS 1. THE CONTRACTOR SHALL MAINTAIN ONE COPY OF DRAWINGS AND SPECIFICATIONS ON THE JOB SITE TO RECORD DEVIATIONS FROM CONTRACT DRAWINGS, SUCH AS: A. LOCATION OF CONCEALED PIPING VALVES AND DUCTS. B. REVISIONS, ADDENDUMS, AND CHANGE ORDERS. C. SIGNIFICANT DEVIATIONS MADE NECESSARY BY FIELD CONDITIONS, APPROVED EQUIPMENT SUBSTITUTIONS, AND CONTRACTOR'S COORDINATION WITH OTHER TRADES. D. EXACT ROUTING OF ALL SANITARY AND DOMESTIC WATER PIPING UNDER FLOOR. THE CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORK UNDER HIS CONTRACT AND SHALL MAKE GOOD, REPAIR OR REPLACE AT HIS OWN EXPENSE, ANY DEFECTIVE WORK, MATERIAL. OR EQUIPMENT WHICH MAY BE DISCOVERED WITHIN A PERIOD OF 12 MONTHS FROM THE DATE OF ACCEPTANCE (IN WRITING) OF THE INSTALLATION BY THE TENANT'S CONSTRUCTION MANAGER. PROVIDE EXTENDED WARRANTIES AS SPECIFIED WITH INDIVIDUAL EQUIPMENT. IN CASE OF REPLACEMENT OR REPAIR OR EQUIPMENT DUE TO FAILURE WITHIN GUARANTEE PERIOD, GUARANTEE ON THAT PORTION OF WORK SHALL BE EXTENDED FOR A PERIOD OF ONE (1) YEAR FROM DATE OF SUCH REPLACEMETN OR REPAIR. OPERATIONS MIAMUALS ONE COPY OF EACH OPERATION AND MAINTENANCE MANUAL FOR ALL EQUIPMENT FURNISHED ON JOB SHALL BE COLLECTED AND INSERTED IN A 3' THREE RING BINDER AND TURNED OVER TO THE TENANT. EACH NOTEBOOK SHALL INCLUDE BUT NOT BE LIMITED TO INSTALLATION, MAINTENANCE AND OPERATING INSTRUCTIONS, PAMPHLETS OR BROCHURES APPROVED SHOP DRAWINGS AND WARRANTIES OBTAINED FROM EACH MANUFACTURER OF PRINCIPAL ITEMS OF EQUIPMENT. THE CONTRACTOR SHALL PROVIDE SLEEVES TO PROTECT EQUIPMENT OR FACILITIES IN THE INSTALLATION. EACH SLEEVE SHALL EXTEND THROUGH IT'S RESPECTIVE FLOOR, WALL OR PARTITION AND SHALL BE CUT FLUSH WITH EACH SURFACE EXCEPT SLEEVES THAT PENETRATE THE FLOOR, WHICH SHALL EXTEND 2' ABOVE THE FLOOR. 2. ALL SLEEVES AND OPENINGS THROUGH FIRE RATED WALLS AND /OR FLOORS SHALL BE FIRE SEALED WITH CALCIUM SILICATE, SILICONE 'RTV' FOAM, '3M' FIRE RATED SEALANTS OR EQUAL, 50 AS TO RETAIN THE FIRE RATING OF THE FLOOR OR WALL. CONFORM TO U.L. ASSEMBLY RATING OF FLOOR OR WALL. 3. SLEEVES IN BEARING AND MASONRY WALLS, FLOORS, AND PARTITIONS SHALL BE STANDARD WEIGHT STEEL PIPE FINISHED WITH SMOOTH EDGES. FOR OTHER THAN MASONRY PARTITIONS, THROUGH SUSPENDED CEILINGS, OR FOR CONCEALED VERTICAL PIPING, SLEEVES SHALL BE HO. 22 U.S.G. GALVANIZED STEEL MINIMUM. 4. DUCT SLEEVES TO BE MINIMUM 14 GAUGE STEEL. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS ANGLE IRON, BANDS, CLAMPS WITH RETAINING CLIPS, CHANNELS, HANGER RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK. 2. HANGERS SHALL BE FASTENED TO BUILDING STEEL, CONCRETE, OR MASONRY, BUT NOT TO PIPING OR DUCTWORK. HANGING FROM METAL DECK IS NOT PERMITTED. RANGERS MUST BE ATTACHED TO UPPER CHORD OF BAR JOIST. WHERE INTERFERENCES OCCUR, IN ORDER TO SUPPORT DUCTWORK OR PIPING, THE CONTRACTOR MUST INSTALL TRAPEZE TYPE HANGERS OR SUPPORTS WHICH SHALL BE LOCATED WHERE THEY DO NOT INTERFERE WITH ACCESS TO FIRE DAMPERS, VALVES, ACCESS DOORS AND OTHER EQUIPMENT SERVICE REQUIREMENTS AND /OR OTHER TRADES. HANGER TYPES AND INSTALLATION METHODS ARE SUBJECT TO LANDLORD CRITERIA. 3. HANGERS FOR ALL INSULATED PIPING SHALL BE SIZED AND INSTALLED FOR THE OUTER DIAMETER OF INSULATION. INSTALL 6' LONG SPLIT CIRCLE GALVANIZED SADDLE BETWEEN THE HANGER AND THE PIPE INSULATION. 4. HANGERS AND PIPING OF DISSIMILAR METALS SHALL BE DI- ELECTRICALLY SEPARATED FROM ONE ANOTHER. FURNISH STEEL ACCESS DOORS AND FRAMES, MIN. 16" X 20" OR AS SHOWN ON DRAWINGS, TO GENERAL CONTRACTOR FOR ALL LOCATIONS WHERE NECESSARY TO PROVIDE ACCESS TO CONCEALED VALVES, AND OTHER EQUIPMENT REQUIRING SERVICE OR INSPECTION. LOCATION. TYPE, SIZE AND NUMBER AS DETERMINED BY CONTRACTOR AND APPROVED BY TENANT CONSTRUCTION MANAGER TO SUIT EQUIPMENT REQUIREMENTS. GENERAL CONTRACTOR WILL INSTALL ACCESS DOORS AND FRAMES. 2. ACCESS DOORS LOCATED IN FIRE -RATED WALLS, FLOORS. CEILING -FLOOR OR CEILING -ROOF ASSEMBLIES SHALL BE FIRE RATED, UNDERWRITER'S LABORATORIES, INC., LISTED AND LABELED. 3. ACCESS DOORS SHALL BE FLUSH TYPE, MANUFACTURED FROM NO. 14 GAUGE STEEL, COMPLETE WITH FLUSH FLANGE TYPE FRAMES MANUFACTURED FROM NO. 16 GAUGE STEEL. PROVIDED WITH ANCHORS. ACCESS DOORS SHALL BE SUITABLE FOR INSTALLATION IN WALL OR CEILING MATERIALS SHOW IN ROOM FINISH SCHEDULES. ELECTRICAL MOTORS FURNISH, INSTALL AND ALIGN ALL MOTORS REQUIRED FOR THIS EQUIPMENT. UNLESS THEY ARE FACTORY INSTALLED ON THE UNIT, ALL STARTERS AND ASSOCIATED WIRING AND SAFETY SWITCHES FOR SUCH MOTORS SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. STARTERS SHALL MEET ALL REQUIREMENTS AS DEFINED IN THE ELECTRICAL DIVISION OF THE SPECIFICATIONS. 2. DESIGN, CONSTRUCTION AND PERFORMANCE CHARACTERISTICS OF MOTORS SHALL CONFORM TO ALL APPLICABLE PROVISIONS OF LATEST NEMA, ANSI, ISEE STANDARDS FOR ELECTRICAL EQUIPMENT. ALL MOTORS SHALL BE SUITABLE FOR OPERATION ON VOLTAGE VARIATION OF PLUS OR MINUS 10%, 40 DEGREES C AMBIENT TEMPERATURE; HAVE A SERVICE FACTOR CF NOT LESS THAN 1.15. LOW VOLTAGE (24 VOLT) WIRING 1. THE CONTRACTOR IS TO INSTALL ALL LOW VOLTAGE WIRING REQUIRED FOR HIS EQUIPMENT. THIS WORK INCLUDES ALL TRANSFORMERS AND DEVICES TO MAKE THIS A COMPLETE FUNCTIONAL SYSTEM. 2. ALL WORK I5 TO CONFORM TO THE LATEST ADDITION N.E.0 AND TO DIVISION 16 ELECTRICAL SPECIFICATIONS. 3. ANY CONDUIT REQUIRED BY CODE OR THE LANDLORD WILL BE INSTALLED BY THE ELECTRICAL SUBCONTRACTOR. B. C. D. PIPING THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE PLUMBING SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: (REFER TO RESPONSIBILITY SCHEDULE FOR EXACT RESPONSIBILITIES) A. B. C. D. E. 4. GAS PIPING DIVISION 15 - MECHANICAL SECTION 15200 PLUMBING COMPLETE SANITARY PIPING SYSTEMS OF WASTE, DRAINS, AND VENTS. COMPLETE COLD AND HOT WATER PIPING SYSTEMS, APPURTENANCES AND INSULATION. PLUMBING FIXTURES AND EQUIPMENT AS SCHEDULED. COMPLETE NATURAL GAS PIPING SYSTEMS (AS APPLICABLE, REFER TO PLANS). TESTS AND ADJUSTMENTS. 2. BEFORE STARTING WORK, THIS CONTRACTOR SHALL EXAMINE THE ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL PLANS AND SPECIFICATIONS TO SEQUENCE, COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE PLUMBING SYSTEM, MATERIALS, AND EQUIPMENT WITH OTHER CONTRACTORS TO AVOID INTERFERENCES AND CONFRONTATIONS. 3. RELOCATION OF EXISTING WATER, GAS, WASTE, VENT, OR DRAINAGE LINES TO FACILITATE STORE DESIGN CRITERIA MUST BE INCLUDED IN BID PROPOSAL. PLUMBING EQUIPMENT GENERAL PIPING REQUIREMENTS GENERALLY, SANITARY AND POTABLE WATER TAPS WILL BE PROVIDED BY THE LANDLORD. FIELD VERIFY EXACT CONNECTION POINTS PRIOR TO SUBMITTING BID AND NOTIFY THE TENANT'S CONSTRUCTION MANAGER IF CONDITIONS ARE NOT AS SHOWN ON THE PLANS OR AS STATED IN THE SPECIFICATIONS. CONTRACTOR MUST VERIFY THE OPERABILITY OF ENTIRE SYSTEM PRIOR TO TIE IN AS FOLLOWS: A. SNAKE SANITARY FOR A DISTANCE OF 100 FEET AND REPORT ANY BLOCKAGE. B. TEST WATER PRESSURE TO INSURE MINIMUM OF 50 PSI. 2. INSTALL ALL NECESSARY PIPE HANGERS, SADDLES, AND CARRIERS TO PROPERLY SUPPORT ALL PIPING AND FIXTURES. HANGERS SHALL SUIT TYPE OF PIPING PROVIDED AND BE SPACED AT A MAXIMUM SPAN OF 5 FEET. PROVIDE SWAY AND SEISMIC BRACING WHERE REQUIRED BY CODES. 3. ESCUTCHEONS SHALL BE CHROME PLATED, SIZE AS REQUIRED AND PLACED AT ALL PIPE PENETRATIONS AT WALLS, FLOORS, AND CEILINGS IN FINISHED AREAS. 4. FLASHING SHALL BE SEALED WATERTIGHT AND PERFORMED IN ACCORDANCE TO THE LANDLORD'S CRITERIA. USE A LANDLORD APPROVED ROOFING CONTRACTOR WHERE APPLICABLE. SANITARY PIPING - NO PVC ALLOWED (STORM PIPING AS REQUIRED) A. WASTE, DRAIN AND VENT PIPING SHALL BE SERVICE WEIGHT, CAST IRON SOIL PIPE. VENT PIPING ABOVE FLOOR 2' OR SMALLER MAY BE GALVANIZED STEEL. B. JOINTS: BELOW FLOOR SLAB - BELL AND SPIGOT WITH CAULKED JOINTS PER CODE. C. PITON WASTE LINES 2' AND SMALLER NOT LESS THAN 1/4' PER FOOT. PITCH LARGER MAINS NOT LESS THAN 1/8" PER FOOT. D. INSTALL A CLEANOUT AT BASE OF EACH SOIL STACK, AT EACH CHANGE IN DIRECTION, AT INTERVALS NOT OVER 50 FEET, AND ELSEWHERE AS SHOWN ON DRAWINGS OR REQUIRED BY LOCAL CODE. CLEANOUTS SHALL NOT BE INSTALLED IN PUBLIC AREAS WITHOUT SPECIFIC PERMISSION BY TENANT'S CONSTRUCTION MANAGER; BUT WHERE NECESSARY. THE WALL COVERS ARE TO BE STAINLESS STEEL AND THE FLOOR COVERS ARE TO BE BRASS (FLUSH WITH FINISHED FLOOR). PROVIDE COVERS WITH INSET AREA FOR CARPETED FLOOR LOCATIONS. ALL CLEAN-OUT LOCATIONS SHALL BE APPROVED BY THE TENANT'S CONSTRUCTION MANAGER. E. INSULATE ALL HORIZONAL RUNS OF PIPING LOCATED IN CEILING SPACES WHEN APPLICABLE. INSULATION TO BE AS SPECIFIED FOR WATER PIPING. F. INSULATE THE TRAP. SANITARY AND SUPPLY PIPES UNDER LAVATORY WITH 1/2' ARMSTRONG "ARMAFLEX" PIPING INSULATION OR TRUEBRO MODEL 102W "HANDI LAY GUARD' INSULATION KIT. 2. CONDENSATE PIPING SHALL BE TYPE 'L' DRAWN COPPER TUBE WITH 95-5 TIN - ANTIMONY SOLDERED JOINTS AND WROUGHT COPPER FITTINGS WITH DIELECTRIC SEPARATION BETWEEN DISSIMILAR METALS. 3. POTABLE WATER PIPING: A. BELOW GRADE: TYPE 'K', ANNEALED TEMPERED COPPER TUBE FOR PIPE SIZES 2 INCHES AND SMALLER. BRAZE ALL JOINTS. B. ABOVE GRADE: TYPE 'L' DRAWN COPPER TUBE WITH WROUGHT COPPER FITTINGS AND 95-5 TIN - ANTIMONY SOLDER. C. INSTALL AIR CHAMBER SHOCK ABSORBERS IN PIPING SYSTEM TO PREVENT NOISE AND DAMAGE DUE TO WATER HAMMER. D. ALL BRANCH PIPING SYSTEM SHALL HAVE ACCESSIBLE SERVICE VALVE. PROVIDE SHUT OFF VALVES IN THE SUPPLY PIPING TO EVERY FIXTURE. PROVIDE ACCESS DOORS WHERE NECESSARY. E. PROVIDE WATER METER AND REMOTE READER PER LANDLORD'S CRITERIA CR LOCAL UTILITIES REQUIREMENTS IF APPLICABLE. REFER TO PLANS TO DETERMINED IF WATER METER IS REQUIRED. F. SECURE PIPE AT ANGLE STOPS. G. PROVIDE FLEXIBLE INSERTS AT ALL PIPE PENETRATIONS THROUGH FRAMING TO KEEP PIPES FROM HITTING FRAME WHEN IN OPERATION. 6. TEST NI: STERILIZATION A. LEAKAGE TESTS SHALL BE PER LOCAL CODES, MINIMUM AS FOLLOWS: 1. TEST POTABLE WATER PIPING AND CONDENSATE PIPING AT 125 PSIG FOR SIX HOURS. 2. TEST DRAIN, WASTE, VENT PIPING BY A 10' WATER COLUMN FOR TWO HOURS. ALL JOINTS SHALL BE GAS AND WATER TIGHT. 3. TEST GAS PIPING WITH PER NFPA 54 CODES. 4. STERILIZE POTABLE HOT & COLD WATER LINES UPON COMPLETION OF SYSTEM. STERILIZE WATER SYSTEM IN ACCORDANCE WITH LOCAL CODES. A. D. SCOPE OF WORK A. SCOPE OF WORK A. PROVIDE A COMPLETE GAS PIPING SYSTEM IF APPLICABLE. REFER TO PLANS TO DETERMINE IF A GAS SYSTEM I5 REQUIRED. B. LOW PRESSURE (14' W.C. AND BELOW) GAS LINES SHALL BE BLACK STEEL, SCHEDULE 40, ASTM A -120, WITH MALLEABLE THREADED FITTINGS FOR 2" AND SMALLER, AND WITH WELDED JOINTS FOR 2 -1/2' AND LARGER. MEDIUM PRESSURE (ABOVE 14' W.C.) SHALL HAVE WELDED JOINTS. C. PROVIDE A GAS COCK, DIRT LEG, AND UNION CONNECTION TO EACH PIECE OF EQUIPMENT. PROVIDE GAS METER AND /OR REGULATOR AS REQUIRED. REGULATOR TO BE VENTED TO THE EXTERIOR. D. PITCH PIPING AT A UNIFORM GRADE OF 1/4' IN 15 FEET UPWARD IN E. PIPI DIRECTION OF FLOW. SUPPORT PIPING EVERY 5 FEET. SUPPORT AS REQUIRED BY LANDLORD CRITERIA, AS DETAILED ON DRAWINGS, OR BY STANDARD INDUSTRY PRACTICE, WHICHEVER IS MORE STRINGENT. E. GAS PIPING EXPOSED ON ROOF MUST BE PAINTED WITH RUST - INHIBITING PAINT. F. INSTALLATION, TESTING AND PURGING OF GAS PIPING SHALL BE DONE PER THE REQUIREMENTS OF THE LOCAL GAS COMPANY, LOCAL CODES, AND 3. APPLICABLE NFPA 54 CODES. G. CONTACT AND COORDINATE GAS SERVICE AND METER REQUIREMENTS WITH 4. THE LOCAL GAS COMPANY AND THE MALL'S MANAGER PRIOR TO BID. 5. INSULATION F. A. INSULATE ALL WATER AND INTERIOR CONDENSATE PIPING WITH 1' THICK (K=0.23 0 75 F) SNAP-ON FIBERGLASS PIPE INSULATION WITH AN ALL SERVICE JACKET TO MEET LOCAL CODES AND UL FLAME SPREAD RATING OF 25 AND SMOKE DEVELOPED RATINGS OF 50. APPROVED MANUFACTURER: MANVILLE MICRO -LOK. THE F.P. CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, 1. SERVICES, TOOLS, TRANSPORTATION AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE SPRINKLER SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: (REFER TO RESPONSIBILITY SCHEDULE FOR EXACT RESPONSIBILITIES) A. INSTALLATION OF NEW WET SPRINKLER SYSTEM AS REQUIRED TO PROVIDE COVERAGE IN ACCORDANCE WITH NFPA -13, LOCAL CODES. LANDLORD'S CRITERIA. AND INSURANCE CARRIERS FOR THE MALL AND TENANT. B. TAPS, RISERS. LATERALS, BRANCHES, VALVES, ALARMS, SPRINKLER HEADS AND ALL COMPONENTS REQUIRED FOR A COMPLETE SYSTEM. C. DESIGN DRAWINGS, CALCULATIONS, SUBMITTALS AND APPROVALS. D. PERMITS, FEES, AND CHARGES. E. TESTS AND TEST CERTIFICATES. F. COST FOR SHUT DOWN FEES. 2. THE CONTRACTOR THAT DOES THE ACTUAL SPRINKLER WORK I5 REQUIRED TO BE A LANDLORD APPROVED SPRINKLER CONTRACTOR. 3. BEFORE STARTING WORK, THE CONTRACTOR SHALL EXAMINE THE ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL PLANS AND SPECIFICATIONS TO SEQUENCE, COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE FIRE PROTECTION SYSTEM, MATERIALS, AND EQUIPMENT WITH OTHER CONTRACTORS TO AVOID INTERFERENCES AND CONFRONTATIONS. 4. RELOCATION OF EXISTING MAINS, LATERALS, BRANCHES AND RISERS TO FACILITATE STORE DESIGN CRITERIA MUST BE INCLUDED IN BID PROPOSAL. B. SHOP 1. 2. TESTS 1. DRAWINGS C. EQUIPMENT THE FIRE PROTECTION CONTRACTOR SHALL PREPARE DETAILED SHOP DRAWINGS AND CALCULATIONS FOR HIS WORK. SUBMIT SIX (6) COPIES TO GENERAL CONTRACTOR FOR APPROVAL. NO WORK SHALL BEGIN UNTIL TENANT'S CONSTRUCTION MANAGER APPROVES HEAD AND PIPING LOCATIONS. 2. THE FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR SUBMITTING COORDINATED DRAWINGS, CALCULATIONS, HEAD TYPES AND COLORS TO ALL AUTHORITIES HAVING JURISDICTION FOR APPROVAL. NO WORK SHALL BEGIN UNTIL ALL APPROVALS HAVE BEEN RECEIVED. 3. A COPY OF THE LETTER OF APPROVAL FROM THE LANDLORD'S INSURANCE RATING BUREAU SHALL BE FORWARDED TO THE LANDLORD'S AGENT AND TO THE TENANT'S CONSTRUCTION MANAGER. SPRINKLER HEADS: A. B. C. D. GENERAL PIPING DIVISION 15 - MECHANICAL SECTION 15300 FIRE PROTECTION ALL SPRINKLER HEADS SHALL BE NEW (EXISTING HEADS SHALL BE REPLACED AS NECESSARY), U.L., F.M. LISTED AND APPROVED AUTOMATIC SPRAY TYPE AS MANUFACTURED BY CENTRAL SPRINKLER 00.. GLOBE, GRINNELL, RELIABLE, STAR, OR VIKING. ALL SPRINKLER HEADS SHALL BE RATED FOR 165'F UNLESS INDICATED OTHERWISE ON DRAWINGS OR REQUIRED BY LOCAL CODES. ALL SALES FLOORS HEADS ARE TO HAVE BE FACTORY APPLIED COLOR FINISH TO MATCH ARCHITECTURAL CEILING FINISH. VERIFY HEAD TYPES AND COLORS WITH TENANT'S CONSTRUCTION MANAGER AND SUBMIT WITH SPRINKLER DRAWINGS FOR PERMIT. SPRINKLER HEAD TYPES SHALL BE AS FOLLOWS: 1. FINISHED CEILING (SALES AREA) - FULLY RECESSED /CONCEALED TYPE 2. FINISHED CEILING (NON-SALES AREA) - SEMI-RECESSED TYPE 3. NO-CEILING - CHROME UPRIGHT TYPE. NOTE:SEMI- RECESSED HEADS SHALL PROTRUDE NO MORE THAN 1' BELIIV LEVEL OF CEILING OF SOFFIT. ALL HORIZONTAL SPRINKLER RUNS AT SIDEWALL SOFFITS SHALL BE CONCEALED WITHIN SOFFIT FRAMING. A FIRE PROTECTION SYSTEM STUB IN SHALL BE FURNISHED BY THE LANDLORD. SPRINKLER SPACING SHALL NOT EXCEED 130 SQ. FT. IN 'SALES' AREAS AND 100 SQ. FT. IN "STOOK" AREAS. COMPLY WITH LANDLORD'S DESIGN CRITERIA. PIPE SIZING SHALL BE BASED ON NFPA ORDINARY HAZARD. 2. ALL SPRINKLER LINES SHALL BE INSTALLED CONCEALED, AVOIDING INTERFERENCE WITH LIGHTS, DUCTS, PIPES, STORAGE DECK, ETC. FIRE PROTECTION CONTRACTOR SHALL PREPARE COORDINATED SHOP DRAWINGS INDICATING THE LOCATIONS OF ALL SPRINKLER HEADS, SPRINKLER LINES, LIGHTS, DIFFUSERS, GRILLES AND REGISTERS PRIOR TO INSTALLATION. HORIZONTAL SPRINKLER RUNS AT MERCHANDISE SOFFITS SHALL BE PLACED INSIDE SOFFIT STRUCTURE. VERTICAL DROPS FROM CEILING TO MERCHANDISE SOFFIT SHALL BE LOCATED FLUSH AGAINST DEMISING WALLS. 3. WHERE POSSIBLE, REWORK THE EXISTING SPRINKLER SYSTEM TO MEET THE NEW REQUIREMENTS OF THIS DESIGN. RELOCATE ALL MAINS AND BRANCHES INTERFERING WITH CEILING HEIGHTS, EQUIPMENT, AND MAJOR COMPONENTS INCLUSIVE OF ADJACENT TENANTS AND MALL COMMON AREAS. REMOVE ALL UNUSED PIPING. 4. LOCATIONS OF ALL HEADS SHOULD BE APPROVED BY THE LOCAL FIRE PROTECTION OFFICIAL AND THE TENANT'S CONSTRUCTION MANAGER BEFORE INSTALLATION. HEADS MUST BE LOCATED IN THE CENTER OF CEILING TILES AND IN A SYMMETRICAL PATTERN WITH OTHER CEILING FIXTURES. ADDITIONAL MONIES WILL NOT BE ALLOCATED FOR ADDITIONAL HEADS REQUIRED BY FIELD FIRE INSPECTOR AFTER BIDS ARE ACCEPTED. HEADS IN MERCHANDISE BAYS SHALL BE CENTERED SIDE TO SIDE AND FRONT TO BACK. 5 PROVIDE AND INSTALL A VALVED TEST CONNECTION FOR THE SPRINKLER SYSTEM AS REQUIRED OR REQUESTED BY THE MALL, LOCAL INSPECTOR, OR INSURANCE CARRIER. COORDINATE LOCATION WITH TENANT'S CONSTRUCTION MANAGER AND LOCAL FIRE PROTECTION OFFICIAL PRIOR TO ROUGH -IN. 6. SPRINKLER HEADS LOCATED IN STOCK, CORRIDOR ON TOILET ROOM CEILINGS OR WALLS BELOW B' -0" ABOVE THE FINISHED FLOOR ARE TO BE PROTECTED WITH APPROVED GUARDS. NG: SCHEDULE 40, BLACK STEEL PIPE, ASTM A-53 FOR FERROUS PIPING, WELDED AND SEAMLESS, ANSI B-36 -10-70 FOR WROUGHT STEEL PIPE. CAST IRON OR MALLEABLE IRON SCREWED FITTINGS FOR PIPES 2 INCHES AND SMALLER. SCREWED OR CAST IRON FLANGED JOINTS FOR PIPES LARGER THAN 2 INCHES. GALVANIZED CR BLACK MALLEABLE IRON WITH BRASS SEAT SCREWED UNIONS FOR PIPES 2 INCHES AND SMALLER. VICTAULIC TYPE COUPLINGS ARE ACCEPTABLE, WHERE APPROVED BY CODE AND THE LANDLORD. WHEN COMPLETED, THE ENTIRE FIRE PROTECTION PIPING SYSTEM SHALL BE HYDROSTATICALLY TESTED AS REQUIRED BY THE RULES AND REGULATIONS OF THE AUTHORITIES HAVING JURISDICTION. SYSTEM SHALL SHOW NO SIGNS OF LEAKAGE OR OTHER DEFECTS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO THE WORK OF THE OTHER CONTRACTORS OR TO THE BUILDING, OR TO ITS CONTENTS, PEOPLE, ETC., CAUSED BY LEAKS IN ANY OF THE EQUIPMENT INSTALLED BY HIM. ALL REPAIRS OR REPLACEMENT OF DAMAGES SHALL BE AT THIS CONTRACTOR'S EXPENSE. 2. PROPERLY COMPLETED AND SIGNED 'SPRINKLER CONTRACTOR'S MATERIAL AND TEST CERTIFICATES' SHALL BE FURNISHED TO THE LANDLORD, AUTHORITIES HAVING JURISDICTION, AND TENANT'S CONSTRUCTION MANAGER. 3. BEFORE STARTING WORK, THIS CONTRACTOR SHALL EXAMINE THE ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL PLANS AND SPECIFICATIONS TO SEQUENCE, COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE HVAC SYSTEM, MATERIALS, AND EQUIPMENT WITH OTHER CONTRACTORS TO AVOID INTERFERENCES AND CONFRONTATIONS. B. HVAC EQUIPMENT DIVISION 15 - MECHANICAL SECTION 15500 HEATING, VENTILATION, AND AIR CONDITIONING THE HVAC CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS. EQUIPMENT, SERVICES. TOOLS, TRANSPORTATION AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE MECHANICAL SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS. AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING:(REFER TO RESPONSIBILITY SCHEDULE FOR EXACT RESPONSIBILITIES) A. ROOFTOP UNITS, EQUIPMENT, AND APPURTENANCES. B. DUCTWORK, FITTINGS. DAMPERS. AND INSULATION. C. HYDRONIC PIPING AND INSULATION (A5 APPLICABLE, REFER TO PLANS). D. REFRIGERANT PIPING (AS APPLICABLE, REFER TO PLANS). E. DIFFUSERS, GRILLES, AND REGISTERS. F. CURBS AND STEEL FRAMING FOR SUPPORT (A5 APPLICABLE, REFER TO PLANS). G. TESTING, ADJUSTING, AND BALANCING. H. OPERATIONS MANUALS. I TEMPERATURE CONTROLS AND RELATED DIAGRAMS. J. SEQUENCES OF OPERATION. K. CONNECTION TO ANY LANDLORD ENERGY MANAGEMENT SYSTEM. PRIMARY HEATING, VENTILATION AND AIR CONDITIONING UNITS. A. PRIMARY HEATING, VENTILATION, AND AIR CONDITIONING UNITS ARE TO BE BY CARRIER AS SCHEDULED. ALL COMPRESSORS ARE TO INCLUDE A 5-YEAR EXTENDED WARRANTY. B. EQUALS EQUIPMENT AS MANUFACTURED BY TRANE OR YORK ARE ACCEPTABLE. C. ALL EQUIPMENT SHALL BE COMPLETE IN EVERY RESPECT WITH ALL DEVICES, APPURTENANCES, AND ACCESSORIES PROVIDED TO MEET THE DESIGN INTENT AND OPERATION OF THE SYSTEMS SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN. D. EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. ALL AIR CONDITIONING EQUIPMENT MUST 16. HAVE A CONDENSATE DRAIN AND BE TRAPPED IN ACCORDANCE WITH MANUFACTURERS DATA. SEE DRAWINGS FOR ADDITIONAL DETAILS. E. SECONDARY DRAIN PANS ARE REQUIRED TO BE INSTALLED BENEATH ALL INDOOR AIR CONDITIONING EQUIPMENT WITH THE EXCEPTION OF VAV BOXES. SECONDARY PANS ARE TO PROTECT ENTIRE UNIT. PROVIDE CONDENSATE PUMPS. AS REQUIRED. CONDENSATE SHALL BE DIRECTED TO MOP SINK OR AS SPECIFIED ON PLANS. 2. VARIABLE AIR VOLUME BOXES (VAV) A. WHERE SHOWN ON DRAWINGS, PROVIDE VAV BOXES COMPLETE WITH CONTROLS, HEATING COILS (FANS AS REQUIRED). ALL DUCT CONNECTIONS FLEXIBLE DUCT/PIPE CONNECTIONS SHALL BE PROVIDED BY THE CONTRACTOR. 3. TOILET EXHAUST FANS A. WHERE SHOWN ON DRAWINGS, PROVIDE A TOILET EXHAUST FAN UNIT COMPLETE WITH GRAVITY BACK DRAFT DAMPERS. ALL DUCTWORK, ROOF OPENINGS AND CAPS NECESSARY TO PROVIDE A COMPLETE EXHAUST SYSTEM SHALL BE PROVIDED BY THE CONTRACTOR. REFER TO PLANS FOR APPLICABILITY. 4. BASEBOARD, CABINET, AND UNIT HEATERS A. WHERE SHOWN ON DRAWINGS, PROVIDE ELECTRIC HEATERS COMPLETE WITH ELECTRIC HEATING COIL, CONTROLS, AND INTEGRAL THERMOSTAT. 5. INLINE PUMPS A. WHERE SHOWN ON DRAWINGS PROVIDE AN INLINE CLOSE COUPLED PUPP(S), BRONZE FITTED, PUMPS SHALL BE FURNISHED WITH BRONZE CASE WEARING RINGS, BRONZE SHAFT SLEEVE AND MECHANICAL SHAFT SEAL RATED FOR. PUMPS TO BE 50 CONSTRUCTED THAT THEY MAY BE MOUNTED IN A HORIZONTAL OR VERTICAL PIPE LINE. MOTOR TO BE 1750 RPM UNLESS NOTED OTHERWISE. 6. VIBRATION ISOLATION DEVICES A. VIBRATION ISOLATION DEVICES SHALL BE PROVIDED IN ALL SUPPORTS BETWEEN VIBRATING EQUIPMENT (FANS. ROOFTOP UNITS. AIR HANDLERS, FAN POWERED VAV BOXES, ETC.) AND STRUCTURE. B. VIBRATING EQUIPMENT HUNG FROM STRUCTURE SHALL BE ISOLATED WITH RUBBER AND SPRING DEVICES. VIBRATING EQUIPMENT SUPPORTED FROM FLOOR OR DECK SHALL BE ISOLATED WITH HOUSED SPRING MOUNT DEVICES. C. EXAMINE DEAD LOAD AND OPERATING LOAD CONDITIONS WHEN SELECTING DEVICES. ADJUST FOR PROPER ALIGNMENT AND LOADING. AVOID 'GROUNDING' THE ISOLATOR. D. CHECK HANGER ROD SIZE FOR ALLOWABLE LOADS AT THE ISOLATING DEVICE AND AT THE UPPER AND LONER ATTACHMENTS TO STRUCTURES, DUCTS, EQUIPMENT, ETC. E. CONSULT MANUFACTURER FOR APPLICATION DATA. 7. CURBS AND STEEL FRAMING FOR SUPPORT A. THIS CONTRACTOR WILL PROVIDE ALL NECESSARY CURBS AND STEEL FRAMING REQUIRED TO INSTALL ALL HVAC EQUIPMENT AS DESCRIBED CR IMPLIED ON THE DRAWINGS. CURBS SHALL BE A MINIMUM OF 14" HIGH, OF THE SAME MANUFACTURER OF THE EQUIPMENT SUPPORTED. INSULATE UNDER THE COMPRESSOR SECTION TO PREVENT CONDENSATION. ALL CURBS MUST BE INSTALLED 50 THAT TOP OF CURBS ARE 'DEAD' LEVEL. ALL PENETRATIONS OF EXISTING STRUCTURE SHALL BE DONE IN ACCORDANCE TO THE LANDLORD'S GUIDELINES AT THIS CONTRACTOR'S EXPENSE. C. METAL DUCTWORK - NO FIBERGLASS DUCT ALLOWED NO DUCTWORK SHALL BE FABRICATED PRIG TO APPROVAL BY THE TENANT'S CONSTRUCTION MANAGER. SIGNIFICANT DEVIATIONS FROM DESIGN MUST BE APPROVED BY TENANT'S CONSTRUCTION MANAGER PRIOR TO FABRICATION OR INSTALLATION. ALL DUCT MAINS ARE TO BE RECTANGULAR UNLESS NOTES OTHERWISE. ALL DUCT BRANCHES TO DIFFUSERS ARE TO BE ROUND RIGID DUCT. 1. (FLEXIBLE DUCT CONNECTIONS TO THE DIFFUSER ARE NOT ALLOWED ON THE SALES FLOOR) 2. EXCEPT AS OTHERWISE INDICATED, FABRICATE AND INSTALL RECTANGULAR DUCTS WITH GALVANIZED SHEET STEEL, IN ACCORDANCE WITH SMACNA 'HVAC DUCT CONSTRUCTION STANDARDS" OF THE LATEST EDITION. CONFORM TO THE REQUIREMENTS IN THE REFERENCED STANDARD FOR METAL THICKNESS, REINFORCING TYPES AND INTERVALS, TIE ROD APPLICATIONS, AND JOINT TYPES AND INTERVALS. 3. EXCEPT WHERE OTHERWISE INDICATED, CONSTRUCT DUCT SYSTEMS TO THE FOLLOWING PRESSURE CLASSIFICATIONS: (VERIFY WHETHER RETURN OR EXHAUST DUCT IS POSITIVE OR NEGATIVE PRESSURE). A. SUPPLY DUCTS: 2 INCHES WATER GAUGE, POSITIVE PRESSURE B. RETURN AND EXHAUST DUCTS: 2 INCHES WATER GAUGE, NEGATIVE PRESSURE. PRESSURE TEST DUCTS FOR LEAKAGE. REMAKE LEAKING JOINTS AND APPLY SEALANTS AS REQUIRED TO FABRICATE A SYSTEM THAT DOES NOT EXCEED 5% LEAKAGE OR LESS AS STATED BY PRESSURE CLASS RATINGS IN SMACNA STANDARDS. 4. AS A MINIMUM, CROSSBREAK ALL FLAT SURFACES OR REINFORCE WITH A BEAD APPROXIMATELY 3/8' WIDE X 3/16' DEEP ON 12' CENTERS TO PREVENT VIBRATIONS. 5. INSTALL DOUBLE THICKNESS TURNING VANES IN ALL RIGHT ANGLE ELBOWS. 6. INSTALL RIGID ROUND AND RECTANGULAR METAL DUCT WITH SUPPORT SYSTEMS INDICATED IN SMACNA STANDARDS. SUPPORT HORIZONTAL DUCTS WITHIN 2 FEET OF EACH ELBOW AND WITHIN 4 FEET OF EACH BRANCH INTERSECTION USING DOUBLE STRAP HANGERS ON EACH SIDE OF FITTING. SUPPORT VERTICAL DUCTS AT A MAXIMUM INTERVAL OF 16 FEET AND AT EACH FLOOR. NO W000 SHALL BE USED TO SUPPORT OR BRACE DUCTS. PROVIDE SWAY AND SEISMIC BRACING AS REQUIRED BY STATE AND LOCAL CODES OR BY LANDLORD. 7. WHERE DUCTS PASS THROUGH ROOFS AND FLOORS, PROVIDE AS MINIMUM 1- 1/2"X1-1/2" X1/8" STEEL ANGLE FRAMES AT EACH SIDE OF OPENING. THE ANNULAR SPACE BETWEEN DUCT AND ANGLE FRAMES SHALL BE CAULKED WITH SILICONE SEALANT OR FIREPROOFED AS REQUIRED BY ASSEMBLY FIRE RATING. 8. ALL TRAVERSE JOINTS AND SEAMS IN SUPPLY AIR DUCT SHALL BE SEALED AIR TIGHT WITH DAP CHIC DUCT SEALER. JOINTS ALSO SHALL BE RIVETED OR CONNECTED WITH SHEET METAL SCREWS. 9. SOFT ELASTOIER BUTYL GASKET WITH ADHESIVE BACKING SHALL BE USED TO SEAL FLANGED JOINTS. 10. DUCT TRANSITIONS SHALL NOT EXCEED 30 DEGREES SLOPE EXCEPT AS SPECIFICALLY NOTED OTHERWISE. 11. PROVIDE ACCESS TO ALL MOTORIZED DAMPERS, FIRE DAMPERS, CONTROLS, AND OTHER ITEMS IN DUCTWORK THAT REQUIRE SERVICE OR INSPECTION. IF THE ACCESS PANEL LOCATION I5 EXPOSED TO THE SALES AREA, IT MUST BE APPROVED BY THE TENANT'S CONSTRUCTION MANAGER PRIOR TO INSTALLATION. LAY -IN SUPPLY AND RETURN AIR DIFFUSERS, GRILLES AND REGISTERS WITH PLASTER FRAMES MAY BE USED AS ACCESS LOCATIONS. D. 12. FLEXIBLE CONNECTIONS 13. 14. 2. A. FLEXIBLE COLLARS SHALL BE PROVIDED IN ALL CONNECTIONS BETWEEN VIBRATING EQUIPMENT (FANS, ROOFTOP UNITS, AIR HANDLERS. FAN POWERED VAV BOXES. ETC.) AND DUCTS OR CASINGS. ALSO, PROVIDE FLEXIBLE CONNECTIONS WHERE DUCTS CROSS BUILDING EXPANSION JOINTS. B. FLEXIBLE CONNECTIONS SHALL CONSTRUCTED OF NEOPRENE-COATED FLAMEPROOF FABRIC. PROVIDE ADEQUATE JOINT FLEXIBILITY TO ALLOW FOR MOVEMENT AND PREVENT THE TRANSMISSION OF VIBRATION. C. FLEXIBLE CONNECTION I5 TO BE RATED FOR THE OPERATING PRESSURE OF THE SYSTEM. FIRE DAMPERS 15. SUPPLY AIR TAKE -OFF FITTINGS A. PROVIDE PRIMARY FIRE DAMPERS WHERE INDICATED OR REQUIRED BY CODES. DAMPERS SHALL BE DESIGNED FOR HORIZONTAL OR VERTICAL FLOW OF AIR AS REQUIRED. FIRE DAMPERS SHALL BE UL LABELED. B. FIRE DAMPERS SHALL HAVE THE BLADES OUT OF THE AIRSTREAM AND A 165'F FUSIBLE LINK. TYPE A, AS MINIMUM. C. PROVIDE ALL NECESSARY FRAMING AND SLEEVES FOR DAMPER MOUNTING PER UL AND CODE REQUIREMENTS. D. PROVIDE DUCT ACCESS DOORS IN AN ACCESSABLE LOCATION FOR ALL FIRE DAMPERS. DOOR I5 TO BE 20 GA GALVANIZED DOOR WITH QUICK-OPENING LATCH AND PIANO HINGE. FLEXIBLE AIR DUCT A. FLEXIBLE AIR DUCT SHALL BE 1" INSULATED CLASS 1 AND RATED FOR THE OPERATING PRESSURE OF THE SYSTEM. DUCT CONSTRUCTION MATERIAL (PLASTIC, CLOTH, ALUMINUM) MUST ADHERE TO LOCAL CODES AND LANDLORD'S REQUIREMENTS AND BE INCLUDED AS SUCH IN THE BID. B. FLEXIBLE AIR DUCT MAY ONLY BE USED IN VERTICAL APPLICATIONS WITH PRIOR APPROVAL FROM TENANT'S CONSTRUCTION MANAGER. C. FLEXIBLE DUCT SHALL NOT EXTEND OVER 5' -0" IN LENGTH AT ANY ONE LOCATION. A. PROVIDE CONICAL OR 'BELL-MOUTH' TAKE -OFFS FROM MAIN DUCTWORK TO ROUND BRANCHES. INSTALL PER MANUFACTURER'S INSTRUCTIONS. B. PROVIDE 45' RECTANGULAR TAKE -OFFS FROM MAIN DUCTWORK TO RECTANGULAR BRANCHES. DAMPERS A. PROVIDE MANUAL LOCKING QUADRANT VOLUME CONTROL DAMPERS WITH HANDLE OPERATORS IN EACH BRANCH DUCT AND AS SHOWN ON PLANS TO FACILITATE AIR BALANCING. B. WHERE ACCESS TO BALANCING DAMPER IS RESTRICTED, YOUNG'S REGULATORS SHALL BE USED. C. ALL RECTANGULAR DAMPERS IN OUTSIDE AIR, RELIEF AIR, OR RETURN AIR DUCTS ARE TO BE OF OPPOSED BLADE TYPE. ALL OUTSIDE AIR DUCT DAMPERS MUST ALSO BE OF THE LOW LEAKAGE TYPE. D. ALL MOTORIZED DAMPERS NOT FURNISHED WITH EQUIPMENT ARE TO BE HONEYWELL DAMPERS. 17. DIFFUSERS, GRILLES, AND REGISTERS A. PROVIDE DIFFUSERS GRILLES AND REGISTERS AS SCHEDULED. DEVICES TO BE COMPLETE WITH DAMPERS FRAMES AND ALL ACCESSORIES. FINISH AS INDICATED. B. INSTALL ALL AIR DEVICES AS LOCATED ON THE ARCHITECTURAL REFLECTED CEILING PLAN. C. APPROVED MANUFACTURERS: TITUS I5 SPECIFIED, EQUALS BY METALAIRE CR KRUEGER IS ACCEPTABLE. 18. MEDIUM PRESSURE DUCT A. WHERE DUCTWORK I5 SPECIFICALLY NOTED AS MEDIUM PRESSURE, IT SHALL BE CONSTRUCTED IN ACCORDANCE WITH SMACNA STANDARDS FOR A PRESSURE RATING OF 3 INCHES WATER COLUMN MINIMUM OR LARGER AS REQUIRED BY LANDLORD. B. ALL GAUGES AND REINFORCEMENT MUST MEET WITH THE LATEST EDITION OF SMACNA STANDARDS FOR MEDIUM PRESSURE DUCT AND WITH THE LANDLORD'S CRITERIA. C. ALL OTHER ITEMS FROM METAL DUCTWORK SPECIFICATION SECTION APPLY TO THIS SECTION 19. DUCTWORK INSULATION A. INSTALL INSULATION PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS, AND IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES. INSULATION MUST COMPLY WITH NFPA 90A. B. DUCT SIZES SHOWN ON DRAWINGS ARE INSIDE CLEAR DIMENSIONS. INSULATE SUPPLY AND RETURN AIR RECTANGULAR DUCTWORK WHERE SHOWN ON PLAN. DUCTWORK SHALL BE EXTERNALLY WRAPPED WITH 1 1/2" THICK, FOIL FACED FIBERGLASS INSULATION. C. ALL ROUND AND OUTSIDE AIR DUCTWORK ABOVE THE CEILING SHALL BE EXTERNALLY INSULATED WITH A MINIMUM OF 1' THICK, 1 -1/2 LB. DENSITY (R=5.6) DUCT WRAP WITH VAPOR BARRIER. VAPOR BARRIER I5 TO BE 1. MAINTAINED THROUGHOUT DUCT SYSTEM. ALL JOINTS MUST BE TAPED 50 THAT NO INSULATION FIBER I5 VISIBLE. EXTEND DUCTWORK INSULATION WITHOUT INTERRUPTION THROUGH WALLS, FLOORS, AND SIMILAR PENETRATIONS. D. DUCKWORK LOCATED IN THE CONDITIONED SPACE SHALL NOT BE INSULATED UNLESS OTHERWISE NOTED ON PLANS. INSULATE ALL DUCT DROPS CR THE FIRST 20 FEET OF DUCT AT THE HVAC UNITS IN ALL CASES. E. ALL INSULATION SHALL HAVE A FLAME SPREAD RATING OF NOT MORE THAN 25 AND A SMOTE DEVELOPED RATING OF NO HIGHER THAN 50 WHEN TESTED IN ACCORDANCE WITH ASTM C 411, OR AS REQUIRED BY LOCAL CODES. 20. SYSTEM CLEANOUT A. DUCTWORK AND AIR HANDLING EQUIPMENT IS TO BE CLEANED OUT AND BLOWN OUT BEFORE PAINTING I5 STARTED BY THE GENERAL CONTRACTOR. B. FILTERS MUST BE IN UNITS AT ANY TIME FANS ARE OPERATED. HYDRONIC PIPING PROVIDE A COMPLETE HYDRONIC PIPING SYSTEM IF APPLICABLE. REFER TO PLANS TO DETERMINE IF A HYDRONIC SYSTEM IS REQUIRED. PIPING A. HYDRONIC PIPING FOR CHILLED WATER AND /OR HEATING WATER AND /OR CONDENSER WATER SHALL BE ASTM A-120. SCHEDULE 40, ERN, BLACK STEEL PIPE WITH PLAIN ENDS. INSTALL STEEL PIPE WITH WELDED JOINTS WHERE PIPE IS 2 -1/2 INCH AND LARGER. INSTALL STEEL PIPE WITH THREADED JOINTS AND FITTINGS OR INSTALL TYPE "K' ANNEALED TEMPERED COPPER TUBE WITH SILFOS JOINTS FOR 2 INCH AND SMALLER PIPE. PROVIDE DIELECTRIC UNIONS BETWEEN DISSIMILAR METALS. ALL PIPING SHALL BE IN STRICT CONFORMANCE WITH ASTM, ASA, AND LANDLORD'S REQUIREMENTS, WHICHEVER I5 MOST STRINGENT. UNIONS OR FLANGES MUST BE USED AT EQUIPMENT CONNECTIONS WHERE SERVICE OR REMOVAL MAY BE REQUIRED. B. ALL PIPING AND EQUIPMENT SHALL BE PRESSURE TESTED WITHOUT LEAKAGE AT A MINIMUM PRESSURE OF 125 PSI. C. ALL HYDRONIC PIPING AND EQUIPMENT CONNECTED TO THE HVAC PIPING SYSTEM SHALL BE CLEANED AND FLUSHED. REMOVE, CLEAN, AND REPLACE STRAINER SCREENS. FILL TENANT'S SYSTEM WITH DOMESTIC WATER AND VENT ALL PIPING AND EQUIPMENT PRIOR TO CONNECTION TO THE LANDLORD'S SYSTEM. CONTRACTOR SHALL NOT FILL TENANT'S SYSTEM WITH WATER FROM THE LANDLORD'S SYSTEM UNLESS SPECIFICALLY INSTRUCTED TO DO 50 FROM THE LANDLORD'S FIELD REPRESENTATIVE. D. PRIOR TO CONNECTION TO THE LANDLORD'S SYSTEM, CONTRACTOR SHALL OBTAIN WRITTEN CONFIRMATION FROM THE LANDLORD'S FIELD REPRESENTATIVE, THAT ALL TESTING, FLUSHING, AND PROPER FILLING OF THE TENANT'S SYSTEM HAS BEEN COMPLETED IN ACCORDANCE TO THE LANDLORD'S REQUIREMENTS AND THAT THE TENANT'S SYSTEM IS READY TO BE CONNECTED TO THE LANDLORD'S SYSTEM. 3. VALVES A. GATE VALVES, 2 -INCH AND SMALLER: CLASS 150, BODY AND UNION BONNET OF ASTM B 62 CAST BRONZE WITH THREADED CR SOLDER ENDS. INTEGRAL SEAT, RENEWABLE SOLID BRONZE WEDGE DISC, RISING STEM, SCREWED BONNET AND RE -PACKABLE UNDER PRESSURE. BALL VALVES ARE ACCEPTED AS AN EQUAL SUBSTITUTION. B. GATE VALVES, 2 -1/2 INCH AND LARGER: CLASS 125 CAST IRON BODY. RENEWABLE BRONZE SEATS AND SOLID WEDGE DISC, RISING STEM, FLANGED ENDS, AND RE- PACKABLE UNDER PRESSURE. C. SWING CHECK VALVES, 2 -INCH AND SMALLER: CLASS 150, CAST BRONZE BODY AND CAP CONFORMING TO ASTM B 62 WITH HORIZONTAL SWING, Y- PATTERN, RENEWABLE BRONZE DISC, PAD HAVING THREADED OR SOLDERED ENDS. D. SWING CHECK VALVE, 2 -1/2 INCH AND LARGER: CLASS 125 CAST IRON BODY AND BOLTED CAP, HORIZONTAL SWING, RENEWABLE BRONZE DISC. FLANGED ENDS AND CAPABLE OF BEING REFITTED WHILE THE VALVE REMAINS IN THE LINE. E. COMBINATION BALANCING AND SHUT-OFF VALVES: BELL & GOSSETT CIRCUIT SETTER WITH LOCKING SETPOINT. A CIRCUIT SETTER BALANCE WHEEL MUST BE INCLUDED WITH 0 & M MANUAL. F. FLOW METER: BELL AND GOSSETT THERMOFLO INDICATOR MODEL TFI. E. REFRIGERANT PIPING F. 4. PIPING SPECIALTIES 5. GENERAL INSTALLATION 6. INSULATION 1 A. PRESSURE/TEMPERATURE TEST PLUGS ( PETE'S PLUG) - 1/4 INCH NNPT FITTINGS TO RECEIVE EITHER A TEMPERATURE OR PRESSURE PROBE, 1/8 INCH O.D. FITTING AND CAPS SHALL BE BRASS WITH VALVE CORE OF NORDEL, RATED AT 400 PSIG, 0'F TO 200'F. B. STRAINERS - 'Y' PATTERN STRAINERS, 125 PSIG, CAST IRON BODY WITH PERFORATED STAINLESS STEEL SCREEN, THREADED FOR 2 INCHES AND SMALLER, FLANGED FOR 2 -1/2 INCHES AND LARGER. SCREEN OPENING SIZE AT 0.033 INCH FOR HEATING AHD 1/8 INCH FOR CHILLED OR CONDENSER WATER. PROVIDE WITH BLOWDOWN VALVE WITH HOSE END FITTING. C. THERMOMETERS - DIE CAST ALUMINUM, 9' INDUSTRIAL MERCURY THERMOMETER, FULLY ADJUSTABLE WITH CLEAR ACRYLIC WINDOW AND BRASS SEPARABLE SOCKET. D. MANUAL AIR VENTS - 1/8' COIN-OPERATED VENT. PROVIDE AN AIR CHAMBER CONSISTING OF A 3/4' NIPPLE AND BUSHINGS. A. INSTALL WATER MAINS WITHOUT PITCH. USE ECCENTRIC REDUCING COUPLINGS AT CHANGES IN SIZE WITH THE TOP OF PIPES AT SAME ELEVATION. MAKE CHANGES IN DIRECTION WITH FITTINGS. B. BRANCHES TO UNITS BELOW MAINS TO BE TAKEN FROM BOTTOM OF MAINS AT A 45 DEGREE ANGLE, PITCH DOWNWARD TOWARD UNITS. BRANCHES TO UNITS ABOVE MAINS TO BE TAKEN FROM TOP OF MAINS AT A 45 DEGREE ANGLE PITCHED UPWARD TOWARDS UNITS. PITCH NOT LESS THAN 1' TO 10 FEET. C. HANGERS SHALL BE SIZED AND INSTALLED FOR THE OUTSIDE DIAMETER OF THE INSULATED PIPE. INSTALL 6' LONG SPLIT CIRCLE GALVANIZED SADDLE BETWEEN THE HANGER AND PIPE INSULATION. D. HANGERS AND PIPING OF DISSIMILAR METALS SHALL BE DIELECTRICALLY SEPARATED FROM ONE ANOTHER. E. SEE PLANS FOR APPLICABLE DETAILS. F. ALL PRESSURE PIPING SYSTEMS INSTALLED SHALL CONFORM TO THE REQUIREMENTS OF THE STATE PIPING AND WELDING CODES. G. INSTALL VALVES AT LOW POINTS FOR DRAINING EACH SYSTEM AND INSTALL MANUAL VENTS AT ALL HIGH POINTS OF EQUIPMENT AND PIPING IN THE SYSTEM TO PROPERLY REMOVE ENTRAPPED AIR. A. ALL HYDRONIC PIPING FOR CHILLED WATER AND /OR HEATING WATER, VALVES, FITTINGS, AND ACCESSORIES SHALL BE INSULATED. FOR PIPE SIZES UP TO 2 INCHES, INSULATE WITH 1 INCH THICK (K=3.23 0 75'F FIBERGLASS INSULATION WITH ALL SERVICE JACKET AND VAPOR BARRIER. FOR PIPE SIZES 2 -1/2 INCHES AND LARGER, INSULATE WITH 1 -1/2 INCH THICK (K=0.23 0 75'F) FIBERGLASS INSULATION WITH ALL SERVICE JACKET AND VAPOR BARRIER. B. INSULATION AT ALL HANGERS FOR PIPING 2 -1/2 INCHES AND LARGER SHALL BE HARD AND NON - COMPRESSIBLE. C. ALL INSULATION SHALL HAVE A FLAME SPREAD RATING OF NOT MORE THAN 25 AND A SMOKE DEVELOPED RATING OF NO HIGHER THAT 50 TO CONFORM WITH THE REQUIREMENTS OF THE NFPA. PROVIDE A COMPLETE REFRIGERANT PIPING SYSTEM BETWEEN INDOOR FAN UNITS AND OUTDOOR CONDENSING UNITS, IF APPLICABLE. PROVIDE OIL. REFRIGERANT CHARGE AND TEST SYSTEM. REFER TO PLANS TO DETERMINE IF A REFRIGERANT PIPING SYSTEM IS REQUIRED. 2. MATERIALS A. REFRIGERANT PIPING SHALL BE TYPE 'L" DRAWN COPPER TUBING (ASTM 888), WROUGHT COPPER OR CAST BRONZE FITTINGS (ANSI B16.22), WITH SILFOS -5 SOLDERED JOINTS. B. SERVICE VALVES, CHARGING PORTS. FILTER - DRIER. SIGHT GLASS, AND A THERMOSTATIC EXPANSION VALVE (TXV) SHALL BE INSTALLED FOR EACH SYSTEM AS A MINIMUM. 3. INSTALLATION A. SIZE LINES WITH ADEQUATE LIFT TRAPS AND DOUBLE SUCTION RISERS AS NECESSARY TO MEET THE NEEDS OF EQUIPMENT SPECIFIED, FIELD CONDITIONS. AND EQUIPMENT MANUFACTURER'S RECOMMENDATIONS. B. PRESSURE TEST FOR LEAKS WITH AN INERT GAS AT 250 PSIG. REDO LEAKING JOINTS AND RETEST UNTIL SYSTEM IS TIGHT. EVACUATE GAS AND CHARGE SYSTEM. RE -TEST SYSTEM AND CHECK FOR LEAKS WITH HALIDE LEAK DETECTOR. ALL LEAKING JOINTS MUST BE COMPLETELY RE- DONE UNTIL NO LEAKS EXIST. C. UPON COMPLETION OF TESTING, BUT BEFORE INSULATION IS APPLIED, PIPING MUST BE INSPECTED BY A REPRESENTATIVE OF THE LOCAL GOVERNING AUTHORITY AS NECESSARY. D. REFRIGERANT LINES SHALL BE INSULATED WITH 1 INCH THICK RUBATEX OR ARMSTRONG REFRIGERANT PIPE INSULATION IN ACCORDANCE WITH INDUSTRY STANDARDS. SYSTEM TESTING, ADJUSTING, AND BALANCING TESTING, ADJUSTING AND BALANCING OF ALL WORK SHALL BE MADE BY AN INDEPENDENT CONTRACTOR WHO I5 CURRENTLY LICENSED ASSOCIATED AIR BALANCING COUNCIL (AABC) OR NATIONAL ENVIRONMENTAL BALANCING BUREAU (NEBB) BALANCING CONTRACTOR. NO OTHER BALANCE REPORTS WILL BE REVIEWED OR ACCEPTED. ALL BALANCING WORK MUST BE COMPLETE AND DONE IN ACCORDANCE WITH THE MOST RECENT STANDARDS OF THEIR SOCIETY. PAYMENT OF ALL COSTS FOR TESTING SHALL BE MADE BY THE HVAC CONTRACTOR. 2. THE HVAC CONTRACTOR SHALL INSTALL NEW FILTERS IN ALL UNITS PRIOR TO THE AIR BALANCE. THE COMPLETE AIR BALANCE SHALL TAKE PLACE WITH OUTSIDE AIR DAMPERS IN MINIMUM POSITION. 3. BALANCE AIR AND WATER QUANTITIES TO WITHIN + 5X OF THAT INDICATED ON THE DRAWINGS. ANY REQUIRED CHANGES IN SHEAVES, BELTS, PULLEYS, OR THE ADDITION OF DAMPERS REQUIRED TO ACHIEVE SPECIFIED FLOW RATES SHALL BE PERFORMED BY THE HVAC CONTRACTOR WITH NO ADDITIONAL CAST TO THE TENANT. 4. THE BALANCE REPORT SHALL INCLUDE AS A MINIMUM THE FOLLOWING INFORMATION: AABC OR NEBB CERTIFICATION NUMBER AND SIGNATURE OF BALANCING CONTRACTOR. INSTRUMENTATION LIST WITH LAST CALIBRATION DATES. MAKE AND MODEL NUMBERS OF ALL HVAC EQUIPMENT TESTED. AIR CFM AND STATIC PRESSURE READINGS (DISCHARGE AND SUCTION) AS MEASURED BY PITOT TUBE DUCT TRAVERSE AT THE UNIT. MOTOR NAMEPLATE DATA WITH ACTUAL FIELD VOLTAGE AND AMPERAGE READINGS FOR EACH LEG. MOTOR AND FAN RPMS, SHEAVE SIZES AND BELT SIZES. OUTSIDE. RETURN, MIXED AND SUPPLY AIR TEMPERATURES AT FULL COOLING. WATER BALANCE DATA INCLUDING GPM WITH INLET AND OUTLET TEMPERATURE AND PRESSURE READINGS (WHERE APPLICABLE). MAKE AND MODEL NUMBERS OF ALL AIR DISTRIBUTION EQUIPMENT. FINAL BALANCED AIR VOLUMES AT ALL OUTLETS (INCLUDING RETURNS WHERE DUCTED). INDEXED PLAN WITH DIFFUSER AND RETURN LOCATIONS. A. B. C. D. E. F. G. H. J. K. L. REPORT SHALL INCLUDE VAV BOX AIRFLOW SENSOR DIFFERENTIAL PRESSURE READING AT MAX. AND MIN. COOLING. 5. ALL CONTROL SEQUENCES SHALL BE TESTED (INTERLOCKED EQUIPMENT, SMOKE DETECTORS, SMOKE EVACUATION, ECONOMIZER, ETC.) AND OPERATING STATUS RECORDED IN THE REPORT. 6. THREE COPIES OF THE BALANCE REPORT SHALL BE SUBMITTED THROUGH THE GENERAL CONTRACTOR TO THE TENANT'S CONSTRUCTION MANAGER FOR APPROVAL. 7. THE BALANCING CONTRACTOR SHALL PERFORM ALL APPLICABLE TESTING AND BALANCING FUNCTIONS REQUIRED FOR THE SYSTEM DESIGNED IN THESE DRAWINGS. THE BALANCING CONTRACTOR SHALL RECHECK ANY ITEMS THAT THE TENANT DEEMS NECESSARY AT NO ADDITIONAL COST TO THE TENANT. 8. FINAL BALANCE REPORT SHALL BE INCLUDED IN THE OPERATION & MAINTENANCE MANUALS. G. FINAL HVAC INSPECTIONS ASIDE FROM NORMAL INTERIM INSPECTIONS OF WORK IN PLACE, THE TENANT SHALL HAVE THE RIGHT TO AN INDEPENDENT HVAC CONTRACTOR INSPECT THE FINISHED HVAC INSTALLATION UPON COMPLETION FOR COMPLIANCE WITH THE PLANS, SPECIFICATIONS, AND CODES. THE INSTALLING CONTRACTOR WILL BE RESPONSIBLE TO BRING ALL ITEMS REPORTED BY THE INDEPENDENT HVAC CONTRACTOR UP TO PLANS AND SPECIFICATION REQUIREMENTS AT NO COST TO TENANT. tr, ra EE F OR P V ' 0 ` MAY 2 2 2i " RECEIVED MAY,14 2008 PERMIT CENTEI Errintinda a, buxeme M- Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 PHONE 614.818.2323 FAX 614.818.2337 WEB www.m - corporations.com SEAL: EXPIRES W 7 DATE: APR 2 8 2003 THE GENERAL CONTRACTOR RAID /OR ALL 3UBCONTRACTOR5 UJORGIN3 FROM THESE PLANS AND SPECIFICATIONS ARE NOT TO SCALE SUCl4 INFORMATION MIT To CONTACT TM$ ARCHITECT OR HI5 REFRE5ENTATIvE 1 aARDIN6 MEASUREMENTS, IF 5UC1-1 MEASUREMENTS DO NOT APPEAR CORRE=CT, ADD UP PROPERLY OR SCALE CORRECTLY TO 114E INDICATED WE. amdliNt T Mitchell NCARB, AIA Architect 6031 1 -20 WEST, SUITE 260 817-265-U15 FAX 817 - 483 -7377 DTMArch itectOOTMArchitect.cam liktirMEMEMEEMY PROJECT: MAIM WORLD PROJECT LOCATION: VITAMIN WORLD 1119 SOUTHCENTER MALL TUKWILA, WA 98180 TOTAL AREA: 900 SF. SHEET TITLE: MECHANICAL SPECIFICATIONS PROJECT NO. 0813048 SCALE: AS NOTED DATE: 4/1/2008 DRAWN BY: LJ REVIEWED BY: TEL SHEET NO. 1N1=3 1 1