HomeMy WebLinkAboutPermit M08-154 - GATEWAY BUILDING 7GATEWAY BLDG 7 12720 GATEWAY DR EXPIRED 12 -03 -08 M07 -154 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: 2716000070 12720 GATEWAY DR TUKW GATEWAY BLDG 7 12720 GATEWAY DR , TUKWILA WA Contractor: Name: MACDONALD /MILLER FAC SOL INC Address: PO BOX 47983 , SEATTLE, WA Contractor License No: MACDOFS980RU CityOf Tukwila DESCRIPTION OF WORK: REPLACE (1) PACKAGED ROOFTOP UNIT, RECONNECT NATURAL GAS LINE TO ROOFTOP UNIT, REPLACE 37 VVT BOXES, INSTALL (1) PARALLEL VAV BOX AND MISC DUCTWORK. Value of Mechanical: 127,796.00 Type of Fire Protection: RREEF AMERICA REIT II CORP/ PO BOX 4900 #207 , SCOTTSDALE AZ CHRIS LEE 7717 DETROIT AV SW , SEATTLE WA Furnace: <100K BTU 0 >100K BTU 0 Floor Furnace 0 Suspended/Wall/Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System.... 0 Air Handling Unit <10,000 CFM 1 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 0 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial/Industrial 0 doc: IMC-10/06 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us MECHANICAL PERMIT EQUIPMENT TYPE AND QUANTITY * *continued on next page ** M08 -154 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 768 -4266 Phone: 206 -763 -9400 Expiration Date: 12/31/2008 M08 -154 06/06/2008 12/03/2008 Fees Collected: $1,463.75 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 38 Printed: 06-06 -2008 Permit Center Authorized Signature: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us tt) Permit Number: M08 -154 Issue Date: 06/06/2008 Permit Expires On: 12/03/2008 Date: Co- io-ff I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction o he performance o work. I am authorized to sign and obtain this mechanical permit. / gn J` Date: bb /�(n CD r Signature: Print Name: /7--t 4) doc: IMC - 10/06 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M08 -154 Printed: 06-06 -2008 Parcel No.: 2716000070 Address: Suite No: Tenant: GATEWAY BLDG 7 1: ** *BUILDING DEPARTMENT CONDPI'IONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us 12720 GATEWAY DR TUKW PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: M08 -154 ISSUED 05/28/2008 06/06/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 15: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the doc: Cond -10/06 M08 -154 Printed: 06 -06 -2008 doc: Cond -10/06 • 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 16: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 17: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 18: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 19: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 20: Local U.L. central station supervision is required. (City Ordinance #2051) 21: The installation of wiring and equipment shall be in accordance with N.F.P.A. 70, Article 760, Fire Protective Signaling Systems. (NFPA 72- 1.3.3) 22: Live or "Hot" parts of electrical equipment operating at 50 volts or more shall be guarded against accidental contact. Install a cover plate to prevent this. (NEC 110.27(2)) 23: To schedule all construction fire - related inspections send an e -mail to fireinsprequest @ci.tukwila.wa.us. Include your name, telephone number, permit number, project name and address and type of inspection requested. 24: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 25: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 26: These plans were reviewed by Inspector 0700. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * * continued on next page ** M08 -154 Printed: 06-06 -2008 Signature: r • City of Tukwila Print Name: l \ 41'(--.1--- doc: Cond -10/06 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Date: 0 6 L. l 0 M08 -154 Printed: 06 -06 -2008 Pik CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No. W1 1 (oO©O ? 0 Site Address: 127 Cq 4TE wpy 7 -rLilC l 4 WA Suite Number: %t—i 1 Floor: Tenant Name: Q TL7 1 P \ (3 Li) Property Owners Name: i-. 'f Mailing Address: — 11 1 �,tr�`lro �' U Q _ S W E -Mail Address: Q:Wpplicationa\Fotms- Applications On Linel3 -2006 - Permit Application.doc Revised: 4 -2006 hh City New Tenant: ❑ Yes No Mailing Address: I 1 2.0 F,AT6 L.+ At..k 'D (Z. $ ut Z (5) " 141A ' to State Zip Name: CA A% LaA Day Telephone. 2 n4.) - yo2 (9(p City Fax Number State Zip Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: . Number: Contractor Registration Number Expiration Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: ber: Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax - •a aer: Page 1 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace> 100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig /Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM ' Incinerator — Comm/Ind Other Mechanical Equipment Q v MECHANICAL CONTRACTOR INFORMATION ' _ / Company Name: M Q.C' O Vtcl (� ` �' ` ! l k-e Mailing Address: "'1 1 "1 T1e Y-c) \k 1 °1. LA-1- S W SCyt. L,.) A 9 5 City State Zip Day Telephone(20 (.) —? (o - L AD- L (p (i E -Mail Address: Fax Number Contractor Registration Number: Wu P►C.O b fZ $ q $ 0 Q, l) Expiration Date: )Z-3 ) — Og Contact Person: Ckv - 1 Valuation of Project (contractor's bid price): $ 2-7 t 1 ctL, Scope of Work (please provide detailed information): RQ.9 \0.Li. rot P +? p tlr� 1 1 rt C.o r rte. o o 1 i V2 t)C 0 U. -,t■a r� 1 c r R vv) -r b�,�c.e c , ; ,� S��) qcx.ir aa\ e d v A v g ©L c2 & S C, cx v C'L'w Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ❑ Replacement Fuel Type: Electric 1 Gas... Other: Indicate type of mechanical work being installed and the quantity below: Q:\Applications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 4 -2006 bh Page 4 of 6 App licable to all permits in this appli PERMIT APPLICATION N OTE Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDIN' S `" : ' _ UTHORIZED Signature: Print Name: Date Application Accepted: Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing code (current edition). Mailing Address: Q:\ Applications \Fo ms- Applications On Line\3 -2006 - Permit Application.doc Revised: 4 -2006 bh Date: 5 - Day Telephone:� "765' Yen s: w� 9 g � 06 City State Zip Date Application Expires: 1451n Staff Initials: Page 6 of 6 Parcel No.: 2716000070 Address: 12720 GATEWAY DR TUKW Suite No: Applicant:. GATEWAY BLDG 7 Receipt No.: R08 -01830 Initials: JEM User ID: 1165 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Payee: MACDONALD- MILLER FACILITY SOLUTIONS, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1731 1,463.75 ACCOUNT ITEM LIST: Description doc: Receiot -06 Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.0 PLAN CHECK - NONRES 000/345.830 Total: $1,463.75 Permit Number: M08 -154 Status: PENDING Applied Date: 05/28/2008 Issue Date: Payment Amount: $1,463.75 Payment Date: 05/28/2008 12:33 PM Balance: $0.00 1,171.00 292.75 2917 05/28 9711 TOTAL 1463.75 Printed: 05 -28 -2008 co!PY • r FOR � CODE COMPLIANCE APPROVE UN - 4 2018 EXPIRES 6/12/ 0 1 STRUCTURAL CALCULATIONS HVAC Support Gateway Corporate Park - Building 7 Seattle, Washington APRIL 14, 2008 PREPARED FOR: RREEF Engineering 12720 Gateway Drive Suite 200 Tukwila, Washington 98168 PREPARED BY: Cascade Crest Consulting Engineers, Inc. 21902 96 Avenue SE Snohomish, Washington 98296 CASCADE CREST CONSULTING ENGINEERS. INC— RECEIVED CITY OF TUKWIL.A MAY 2 8 2008 'ERMIT CENTER AA Oioloir S 9 ThL L b 1 e_ Loa_ 6 5" 0 PIT 9 0 4, . pt.- Lc r - - I - t ( Casco.= CEresr Copasuvrwa lv \•11`1 7 4 iL 5 pe oC - s * 6) /3 64 - L P PROJECT: Elk:FEW& I coo. P -7f ENGR: DATE: T- (-J-r A° I co ogf A-) t 1 5 Ce7; tee €03 e 1 ea. 6 k-- to-7, SCALE: 6 7. ( t 11( a a if --f - 19 - 1 - AP.- 8 Acawf. . SHEET - ®WN�f�ill�H IN immorelatkrizRa-ati•v--2.1 r&Minitiossim MEI ga —a �i' .: { - ;;'1, - ^rErl13:<ttti _V��ti7,ihiJidGdlt� '"�!. � :. ��� ,M•.oO o f7r r a.r Le,r 'llGiiil�l`i�r H9• �� � e•.,, liFiA3R�•r�d)Y�� T A a11�1`yi�7,`1rl$t) ""i.fpn:� .L -y _ -- . .w ••a•}i; e. i.�- 0 ''sc�`. �:3� 'x. Yil].: .0 - a 7C47-'-'W . x , � y ,.'• - . y► . • , ^ lH� •∎ • }3 p3'.C`h. i b+iiW �x �7 vina.s�� �MO'u7' o�i'riq+ Mo'> c01 c, cot !Y3 'irci a gin 1 -'1 7 1 svD i a /9 1. 1r Performance Summary for 60 TON PURON Project Name: Gateway Building # 7 - PHASE 2 01/15/2008 Prepared by: Andrew Maxey 07:19PM Part Number: 48A3TO60DSV611 HM EER (ARI 360) 10.10 IPLV 9.5 Shipping Dimensions: Unit Length: 25' 11" ~� Unit Width: r 10"� Unit Height Unit Shipping Weight 8566.0 lb Heating Type Gas Supply / Return Vertical Application Type VAV Cooling Airflow 24000 CFM Altitude 0 ft Cond. Ent. Air Temp 95.0 °F Ent. Air Dry Bulb 80.0 °F Ent. Air Wet Bulb 67.0 °F Ent. Air Enthalpy 31.44 BTU/lb Lvg. Air Dry Bulb 59.0 °F Lvg. Air Wet Bulb 58.1 °F Lvg. Air Enthalpy 25.12 BTU/lb Gross Cooling Capacity 681.88 MBH Gross Sensible Clg. Cap. 543.77 MBH Compressor Power 49.47 kW Coil Bypass Factor 0.060 Note Standard Coil Used Capacity Stages (% Full) Multiple Stage w/ HGBP: 18,25,50,75,100 Heating Capacity Type High Gas Heat Unit Control Type Staged Gas Control Number of Heating Steps 9 Max Heating Input 1164.0 MBH Heating Airflow 24000 CFM Heating Ent. Air Temp. 68.0 °F Min HeatingCap (Output) 238.6 MBH Max HeatingCap (Output) 954.4 MBH Heating Lvg. Air Temp. 104.8 °F Steady State Elf 82 Temp. Rise 36.8 °F Capacity Stages - Heat (% Full) 25, 33, 50, 58, 67, 75, 83, 92,100 Ext. Static Pressure 1.20 in wg Selection External Static Pressure 1.20 in wg Supply Fan Type Forward Curve Supply Fan RPM 1010 Supply Fan BHP 28.3 BHP Supply Fan Motor HP 30.0 hp P.E. Airflow 17550 CFM P.E. Max. Available Ext. Static 0.04 in wg Note High Speed (Pwr. Exh.) Electrical Data Volts- Phase -Hertz 4603 -60 Voltage Range 414 - 508 Comp. Cir. A, No.1 RLA 22.4 Comp. Cir. A, No.1 LRA 150 Comp. Cir. A, No2 RLA 224 Comp. Cir. A, No2 LRA 150 Comp. Cir. B, No.1 RLA 22.4 Comp. Cir. B, No.1 IRA 150 Comp. Cir. B, No2 RLA 22.4 Comp. Cir. B, No2 LRA 150 Condenser Fan Qty 4 Condenser Fan FLA (ea) 2.9 Evap. Fan Motor HP 30 Evap. Fan Motor FLA 40 P.E. / R.F. Motor FLA 18.9 Power Supply MCA 173.6 Power Supply MOCP 200.0 4 3 5-1) e � (d CO Applied RTU Builder v1.590 Page 1 of 2 Performance Summary for 60 TON PURON Project Name: Gateway Building # 7 - PHASE 2 01/15/2008 Prepared by: Andrew Maxey 07:19PM 48A3060 8 10 12 14 16 18 20 22 24 26 28 AIRFLOW (1000 CFM) Legend: \ -RPM \ -HP RPM =1010 BHP =28.3 Max RPM = 1200 Max HP = 40.0 RPM's (x 100, T ton 1211 109876543 HP's (L to RI 25 30 35 40 50 Application Note: 1. Base fan performance includes wet evaporator coil, dean 2-inch (51 -mm) filters and cabinet effects. 2. Supply Fan performance is based on the HIGHER of the cooling or heating design airflow rates. Select and adjust air terminals accordingly to accomodate this selection. Acoustics: Sound Power Levels, dB re 10E -12 Watts Discharge inlet Outdoor 63 Hz 92.2 92.3 NA 125 Hz 92.3 84.1 100.0 250 Hz 94.8 80.9 98.0 500 Hz 89.5 77.1 97.0 1000 Hz 88.8 77.8 97.0 2000 Hz 87.0 75.1 95.0 4000 Hz 83.6 73.6 90.0 8000 Hz 76.9 68.5 90.0 Note: Indoor fans rated in accordance with ARI Standard 260. Outdoor fan's ratings tests conducted in accordance with AR! Standard 270 - Sound Rating for Outdoor Unitary Equipment Applied BTU Builder v1.590 Page 2 of 2 March 7, 2008 RREEF Engineering 12720 Gateway Drive Suite 200 Tukwila, WA 98168 Attention: Greg Coleman RE: Structural Review Gateway Corporate Center Building 7 Seattle, Washington Dear Greg: Existing Building Description Observations and Evaluation 21902 96 Ave. S.E. - Snohomish, WA 98296 - Phone: 206 - 909 -7808 - Fax 360 -668 -8739 CASCADE CREST CONSULTING ENGINEERS. INC. Cascade Crest Consulting Engineers, Inc. has performed an evaluation of the existing framing supporting the mechanical equipment on the roof of Building 7 at Gateway Corporate Center in Seattle, Washington. The purpose of the evaluation was to determine whether the existing framing can support a new HVAC unit between gridlines B/C and 2/3 that weighs more than the weight of the original unit specified on the construction drawings. This letter summarizes our findings and recommendations. The existing Building 7 is a two-story concrete tilt -up structure with steel framed roof and floor framing systems. Typical roof framing utilizes 1 -1/2" metal deck supported by open web steel joists, which are in turn supported by steel joist girders. In the areas of the existing HVAC units on the roof, a concrete topping slab has been placed over the existing metal deck with an overall thickness of 4 ". Typical floor framing consists of metal deck with a concrete topping slab supported by open web steel joists, which are in turn supported by steel joist girders. Steel tube columns and the perimeter concrete tilt -up wall panels support the roof and floor framing. The ground floor consists of a concrete slab-on- grade. Based upon a brief site visit, the building was erected according to the construction documents provided to this office. The drawings were titled "Kaiser Gateway Associates — Gateway Corporate Center —Phase 3 ", by LPN Architects, dated 8/19/88. These drawings indicate that the structure was designed to support a mechanical unit weighing 8,000 pounds. As reflected in the information provided to this office, the new unit and curb will weigh approximately 9,000 pounds. The overall dimensions of the unit are approximately 26' x 8'. An evaluation of the steel beams supporting the existing HVAC unit between gridlines B/C and 2/3 indicates that the beams have adequate capacity to support the weight of the proposed new HVAC unit. Gateway Corporate Park - Building 7 Recommendations It is anticipated that the existing unit will be replaced in its entirety prior to placing the new unit. In placing the curb for the new unit on the roof, the curb in the longitudinal direction should be centered over the existing W21x57 steel wide flange beams. We are pleased to assist you on this project. Should you have questions, please feel free to call me at (206) 909 -7808 and discuss our findings. Sincerely, CASCADE CREST CONSULTING ENGINEERS INC. / / Keith Wm. Moore, S.E. Associate 2 March 7, 2008 - 4• 0.5 b; ► e P 574c_ CCU 7 4 hZ 0 c). (0, 734) 6 ( • ,:4 I 0 ° id..__ J . rr3 , w1, pre- 7 A pi i bc eete. oety` -e e 4 F_ 6- -k > t (4.5,e_ ) 6?, o �� `±Ycy U I , 4 � I ``A () ,* 10 7"- isia_A,^. ,v �c Cc- (� UTE (g) r eksz.e_ " - ryt- Uit-C c O&_ C servos caffar co rsucroaa E]nimeEIVIs bac. PROJECT: ENGR: DATE: '/ / SCALE: 4 SHEET Conterminous 48 States 2002 Data Uniform Hazard Spectrum (UHS) for 2 % PE in 50 years Latitude = 47.4900 Longitude = - 122.2700 B/C Boundary Data are based on a 0.05 deg grid spacing Period Sa Sd (sec) (g) (inches) 0.000 0.657 0.000 0.100 1.263 0.123 0.200 1.475 0.576 0.300 1.297 1.140 0.500 0.988 2.414 1.000 0.507 4.956 2.000 0.223 8.697 • Screw Table Notes 1. Screw spacing and edge distance shall not be less than 3 x D. (D = Nominal screw diameter) 2. The allowable screw values are based on the steel properties of the members being connected, per AISI section E4. 3 When connecting materials of different metal thicknesses or yield strength, the lowest applicable values should be used. 4. Screw strength needs to be verified by the screw manufacturer. 5. Values include a 3.0 factor of safety. 6. Applied loads may be multiplied by 0.75 for seismic or wind loading, per AISI A 5.1.3. 7. Allowable loads are based on mill certified stel. r- KNORR Allowable Loads for Screw Connections Weld Table Notes 1. Weld capacities based on AISI, section E2 2. When connecting materials of different metal thicknesses or yield strength, the lowest applicable values should be used. 3. Values include a 2.5 factor of safety. 4. Applied loads may be multiplied by 0.75 for seismic or wind loading per AISI A 5.1.3. 5. Allowable loads are based on mill certified stel. Allowable Loads for Fillet Welds and Flare Groove Welds 41 Design Properties - 66 Screw #8 Screw #10 Screw - #12 Screw I Thickness Yield Tensile Shear Pullout Shear Pullout Shear Pullout Shear Pullout MU in. ksi kc lbs. lbs. lbs. tbs. lbs. lbs. lbs. lbs. 879 0.0188 44VV482 8888885 60 33 66 39 71 46 75 52 0.0283 111 50 121 59 131 69 139 78 0.0312 129 55 141 65 151 76 161 86 8 MON 0.0346 151 61 164 72 177 84 188 95 0.0451 224 79 244 94 263 109 280 124 0.0566 455 144 496 171 534 198 569 225 0.0713 576 181 684 215 _ 755 249 805 284 • Screw Table Notes 1. Screw spacing and edge distance shall not be less than 3 x D. (D = Nominal screw diameter) 2. The allowable screw values are based on the steel properties of the members being connected, per AISI section E4. 3 When connecting materials of different metal thicknesses or yield strength, the lowest applicable values should be used. 4. Screw strength needs to be verified by the screw manufacturer. 5. Values include a 3.0 factor of safety. 6. Applied loads may be multiplied by 0.75 for seismic or wind loading, per AISI A 5.1.3. 7. Allowable loads are based on mill certified stel. r- KNORR Allowable Loads for Screw Connections Weld Table Notes 1. Weld capacities based on AISI, section E2 2. When connecting materials of different metal thicknesses or yield strength, the lowest applicable values should be used. 3. Values include a 2.5 factor of safety. 4. Applied loads may be multiplied by 0.75 for seismic or wind loading per AISI A 5.1.3. 5. Allowable loads are based on mill certified stel. Allowable Loads for Fillet Welds and Flare Groove Welds 41 Design - Steel Proyertles MU I Thickness Yield Tensile E60XX Electrodes in. Irsl ksi lbsfln 0.0451 444888 609 0.0566 764 0.0713 963 Q 0.0451 St 879 0.0566 1104 0.0713 1390 • Screw Table Notes 1. Screw spacing and edge distance shall not be less than 3 x D. (D = Nominal screw diameter) 2. The allowable screw values are based on the steel properties of the members being connected, per AISI section E4. 3 When connecting materials of different metal thicknesses or yield strength, the lowest applicable values should be used. 4. Screw strength needs to be verified by the screw manufacturer. 5. Values include a 3.0 factor of safety. 6. Applied loads may be multiplied by 0.75 for seismic or wind loading, per AISI A 5.1.3. 7. Allowable loads are based on mill certified stel. r- KNORR Allowable Loads for Screw Connections Weld Table Notes 1. Weld capacities based on AISI, section E2 2. When connecting materials of different metal thicknesses or yield strength, the lowest applicable values should be used. 3. Values include a 2.5 factor of safety. 4. Applied loads may be multiplied by 0.75 for seismic or wind loading per AISI A 5.1.3. 5. Allowable loads are based on mill certified stel. Allowable Loads for Fillet Welds and Flare Groove Welds 41 Gateway Building 7 West RTU Upgrade Location Building owner Program user Company Comments By Dataset name Calculation time TRACE® 700 version Location Latitude Longitude Time Zone Elevation Barometric pressure Pe 1 ,., ,��. �' -- Latent heat factor Enthalpy factor ,41111 MANE tto. • - Air,density specific heat Density- specific heat product Summer design dry bulb Summer design wet bulb Winter design dry bulb Summer clearness number Winter clearness number Summer ground reflectance Winter ground reflectance Carbon Dioxide Level Design simulation period Cooling load methodology Heating load methodology 12720 Gateway Dr, Tukwila, WA RREEF Chris Lee MacDonald Miller Facility Solutions Replace West 60 ton RTU and replace existing VVT boxes with new VVT system using Nailor squeezeboxes This file is a complete load profile for both floors of the entire MacDonald - Miller C:ICDSITRACE7001Projects1738 -6215 Gateway Bldg7 Phasi 10:35 AM on 05/16/2008 6.1.2 Seattle, Washington 47.0 deg 122.0 deg 8 386 ft 29.5 in. Hg 0.0749 0.2444 1.0988 4,836.9 4.4953 85 67 24 0.95 0.95 0.20 0.20 400 lb/cu ft Btu /1b - °F Btu /h- cfm• °F Btu•min /h•cu ft lb-min/hr-cu ft °F °F °F ppm January - December CLTD -CLF (ASHRAE TFM1 UATD RECEIVED CITY OF TUKWILA MAY 2 8 2008 PERMIT CENTER �ell-M ba TIYY 229 -1 P Theory 3 229 -2 Theory 3 VAV -229 VAV -229 230-1 P Theory 3 230 -2P Storage VAV -230 VAV -230 231 -1P Lab 6 VAV -231 VAV -231 232-1P Lab 8 VAV -232 VAV -232 RTU 12 TON FL2 SW ZONE RTU 12 TON FL2 SW ZONE NO CONTROL -201 NO CONTROL -202 101-1P Staff lounge 101 -2P VAV -101 VAV -101 102-1P Theory 2 102 -2 Theory 2 VAV -102 VAV -102 103-1P LRC 103 -2 LRC VAV -103 VAV -103 104 -1P Office 104 -2P Office 104 -3P Conf rm (no av equip) System Zone Room " hlterr ative; FCU -201 -1 Rm Peak 130 0.9 1,794 2,127 79 Sys Peak 130 0.9 1,794 2,127 79 Sys Block 130 0.9 1,794 2,127 79 Rm Peak 216 5.0 9,830 11,450 467 Rm Peak 347 8.0 8,679 11,905 355 Zn Peak 563 13.0 18,874 23,720 821 Zn Block 563 13.0 17,508 22,648 820 Rm Peak 502 12.0 24,274 28,161 1,164 Rm Peak 159 0.0 1,615 1,656 73 Zn Peak 661 12.0 25,931 29,859 1,236 Zn Block 661 12.0 26,130 29,763 1,236 Rm Peak 882 25.0 44,001 51,481 2,049 Zn Peak 882 25.0 44,001 51,481 2,049 Zn Block 882 25.0 44,001 51,481 2,049 Rm Peak 1,010 28.0 47,089 55,467 2,171 Zn Peak 1,010 28.0 47,089 55,467 2,171 Zn Block 1,010 28.0 47,089 55,467 2,171 Sys Peak • 3,116 78.0 139,579 164,212 6,278 Sys Block 3,116 78.0 127,544 156,629 6,096 Rm Peak 84 0.6 1,191 1,420 50 Rm Peak 416 2.9 5,896 7,033 249 Rm Peak 346 6.0 8,666 11,010 350 Rm Peak 120 0.8 3,012 3,340 137 Zn Peak 466 6.8 11,678 14,350 486 Zn Block 466 6.8 11,674 14,346 485 Rm Peak 308 8.0 7,697 10,841 301 Rm Peak 596 22.0 15,465 24,827 562 Zn Peak 904 30.0 23,343 35,849 863 Zn Block 904 30.0 22,990 35,757 860 Rm Peak 285 12.0 15,821 19,938 676 Rm Peak 817 13.0 17,299 21,759 734 Zn Peak 1,102 25.0 33,121 41,696 1,410 Zn Block 1,102 25.0 33,100 41,676 1,410 Rm Peak 127 1.0 2,551 2,942 111 Rm Peak 108 1.0 2,771 3,120 127 Rm Peak 115 6.0 4,924 7,268 165 gWZ FCU FCU " This report does not display heating only systems. Load / Airflow Summary By MacDonald - Miller Coil Coil Space Floor Cooling Cooling Design Air Area People Sensible Total Max SA Changes ft' # Btu /h Btu /h cfm ach/hr VAV Minimum SA cfm Main Coil Heating Heating Fan Percent ASHRAE Sensible Max SA OA Std 62 Btu /h cfm 4.32 0 -3,215 79 23.1 23.1 -3,215 79 23.1 23.1 -3,215 79 23.1 23.1 15.44 0 -8,656 467 16.1 16.1 7.30 0 - 11,041 355 33.8 33.8 - 19,697 820 23.8 23.8 - 19,689 820 23.8 23.8 16.56 0 - 21,084 1,164 15.5 15.5 3.26 0 -1,421 73 17.5 17.5 -22,504 1,236 15.6 15.6 -22,504 1,236 15.6 15.6 16.59 0 - 41,236 2,049 18.3 " 18.3 - 41,236 2,049 18.3 18.3 - 41,236 2,049 18.3 18.3 15.36 0 -45,303 2,171 19.3 19.3 -45,303 2,171 19.3 19.3 -45,303 2,171 19.3 19.3 - 128,741 6,096 19.4 19.4 - 128,457 6,096 19.4 19.4 4.28 , 0 - 1,230 50 23.3 23.3 4.28 0 -6,091 249 23.3 23.3 7.22 0 - 11,225 350 34.3 34.3 8.14 0 -2,282 137 12.3 12.3 - 13,508 485 28.2 28.2 - 13,498 485 28.2 28.2 6.97 0 - 10,828 301 39.9 39.9 6.73 0 - 27,628 562 58.7 58.7 - 38,456 860 52.3 52.3 - 38,433 860 52.3 52.3 16.94 0 - 18,069 676 26.6 26.6 6.41 0 - 19,585 734 26.6 26.6 - 37,655 1,410 26.6 26.6 - 37,655 1,410 26.6 26.6 " 6.26 0 -2,302 111 18.0 18.0 8.43 0 -2,433 127 15.7 15.7 10.28 0 -9,731 165 72.5 72.5 Clg Htg OA Fraction Project Name: Gateway Building 7 West RTU Upgrade TRACE® 700 v6.1.2 calculated at 10:35 AM on 05/16/2008 Dataset Name: C: \CDS \TRACE700 \Projects1738 -6215 Gateway Bldg7 Phase 2 \GATEWAY7- PH2.TRC Load /Airflow Summary Report Page 1 of 9 System Zone Room " 104-4P 104 -5P 104-6P VAV -104 VAV -104 105-1P 105-2P 105-3 105-4 VAV -105 VAV -105 106-1 P 106 -2P 106-3P 106-4P VAV -106 VAV -106 107-1P 107 -2P VAV -107 VAV -107 108 -1P Conf Rm 108 -2P 108-3P VAV -108 VAV -108 109-1P Conf Rm 109 -2P Conf Rm 109 -3 109-4 Corridor VAV -109 VAV -109 110 -1P 110-2P VAV -110 VAV -110 111 -1P Testing Rm 111 -2 Testing Rm VAV -111 VAV -111 112 -1P VAV -112 VAV -112 "This report Project Name: Dataset Name: does not display heating only systems. Coil Coil Space VAV Main Coil Heating Floor Cooling Cooling Design Air Minimum Heating Fan Percent ASHRAE Area People Sensible Total Max SA Changes SA Sensible Max SA OA Std 62 - ft # _ Btu /h .-. ... .Btu /h _.. cfm... _ .rach/hr_ - cfm Btu /h -- - cfm -- CI g - --Htg OA Fraction Rm Peak 234 1.6 5,270 5,909 237 7.23 0 -4,209 237 13.8 13.8 Rm Peak 116 0.8 2,891 3,208 131 8.09 0 -2,200 131 12.4 12.4 Rm Peak 150 1.0 4,041 4,450 185 8.81 0 -2,968 185 11.3 11.3 Zn Peak 850 11.5 22,503 26,952 957 - 23,843 953 24.1 24.1 Zn Block 850 11.5 22,368 26,860 953 - 23,804 953 24.1 24.1 Rm Peak 116 0.8 2,293 • .2,610 101 6.24 0 -1,956 101 16.0 16.0 Rm Peak 116 0.8 2,923 3,240 133 8.19 0 -2,213 133 12.2 12.2 Rm Peak 600 4.2 8,533 10,172 362 4.32 0 -8,808 362 23.2 23.2 Rm Peak 187 1.3 2,659 3,170 113 4.32 0 -2,745 113 23.2 23.2 Zn Peak 1,019 7.1 16,408 19,192 • 710 - 15,723 708 20.1 20.1 Zn Block 1,019 7.1 16,396 19,180 708 - 15,710 708 20.1 20.1 Rm Peak 116 0.8 2,923 3,240 133 8.19 0 -2,213 133 12.2 12.2 Rm Peak 118 0.8 2,952 3,274 134 8.12 0 -2,243 134 12.3 12.3 Rm Peak 118 0.8 2,155 2,477 94 5.69 0 - 1,916 94 17.6 17.6 Rm Peak 108 1.0 2,440 2,831 106 7.04 0 -2,262 106 18.8 18.8 Zn Peak 460 3.5 10,469 11,822 467 -8,634 467 14.8 14.8 Zn Block 460 3.5 10,468 11,821 467 -8,633 467 14.8 14.8 Rm Peak 222 1.6 7,135 •7,809 348 11.20 0 - 4,997 348 8.9 8.9 Rm Peak 152 1.1 5,715 6,090 279 13.11 0 -3,750 279 7.6 7.6 Zn Peak 374 2.6 13,093 14,142 627 -8,747 627 8.3 8.3 Zn Block 374 2.6 12,035 13,171 627 -8,746 627 8.3 8.3 Rm Peak 230 6.0 6,949 9,065 310 9.63 0 - 10,906 310 38.7 - 38.7 Rm Peak 152 1.0 5,322 5,675 259 12.17 0 -3,501 259 7.7 7.7 Rm Peak 141 1.0 6,203 6,555 ' 304 15.41 0 . -3,866 304 6.6 6.6 Zn Peak 523 8.0 18,474 21,295 873 - 18,273 873 18.3 18.3 Zn Block 523 8.0 18,474 21,295 873 - 18,273 873 18.3 18.3 Rm Peak 144 5.0 8,940 11,114 417 20.70 0 - 10,377 417 24.0 24.0 Rm Peak 183 5.0 9,489. 11,130 438 17.08 0 - 10,543 438 22.8 ' 22.8 Rm Peak 190 1.3 2,702 3,221 115 4.32 0 -2,789 115 23.2 23.2 Rm Peak 478 0.0 4,457 . 4,702 200 2.99 0 -4,298 200 19.1 . 19.1 Zn Peak 995 11.3 24,533 29,113 1,170 - 28,007 1,164 22.8 22.8 Zn Block 995 11.3 25,613 . 29,579 1,164 - 27,958 1,164 22.8 22.8 Rm Peak 462 3.2 21,007 22,068 1,024 15.83 0 - 12,826 1,024 6.3 6.3 Rm Peak 204 1.4 9,659 .10,127 473 - 16.58 0 - 5,837. 473 6.0 6.0 Zn Peak 666 4.7 30,666 32,195 1,497 - 18,663 1,497 6.2 6.2 Zn Block 666 4.7 30,660 32,189 1,497 - 18,663 1,497 6.2 6.2 Rm Peak 116 6.0 7,492 9,462 331 20.38 0 - 11,074 331 36.3 36.3 Rm Peak 257 6.0 4,502 6,846 141 3.93 0 ' -9,534 141 85.0 85.0 Zn Peak 373 12.0 12,909 17,223 472 - 20,609 468 51.3 51.3 Zn Block 373 12.0 11,399 16,482 468 - 20,572 468 51.3 . 51.3 Rm Peak 133 1.0 6,026 6,354 295 15.85 0 -3,793 295 6.8 6.8 Zn Peak 133 1.0 6,026 6,354 295 -3,793 295 6.8 6.8 Zn Block 133 1.0 6,026 6,354 295 -3,793 295 6.8 6.8 Gateway Building 7 West RTU Upgrade TRACE® 700 v6.1.2 calculated at 10:35 AM on 05/16/2008 C: \CDS \TRACE700 \Projects \738 -6215 Gateway Bldg7 Phase 2 \GATEWAY7- PH2.TRC Load /Airflow Summary Report Page 2 of 9 Coil Coil Space VAV Main Coil Heating Floor Cooling Cooling Design Air Minimum Heating Fan Percent ASHRAE Area People Sensible Total Max SA Changes SA Sensible Max SA OA Std 62 - System Zone Room " . , _ ft'_. _ ft..._ . _Btu/h-. - .._Btu /h --- -- cfm - - •ach/hr•' cfm Btu /h ., -. 'cfm - Clg Htg - OA Fraction' 113 -1P Rm Peak 330 4.0 18,562 19,703 894 19.34 0 - 12,845 894 9.0 9.0 113 -2 Rm Peak 474 3.0 5,693 6,865 236 3.56 0 -6,111 236 25.4 25.4 VAV -113 Zn Peak 804 7.0 23,626 25,939 1,130 - 18,955 1,122 12.5 12.5 VAV -113 Zn Block 804 7.0 23,943 25,939 1,122 - 18,895 1,122 12.5 12.5 114 -1P South entrance Rm Peak 411 0.0 33,246 33,378 1,697 29.50 0 ' - 15,212 1,697 1.2 1.2 114 -2 Corridor Rm Peak 1,577 0.0 7,220 8,696 261 1.18 0 - 10,940 261 48.3 48.3 VAV -114 Zn Peak 1,988 0.0 39,168 40,777 1,959 . - 26,152 1,940 7.6 7.6 VAV -114 Zn Block 1,988 0.0 39,822 40,763 1,940 - 26,003 1,940 7.6 7.6 115-1 Rm Peak 892 6.2 12,686 15,123 539 . 4.32 0 - 13,094 539 23.2 23.2 115-2 Rm Peak 157 1.1 2,233 2,662 95 4.32 0 -2,305 95 23.2 23.2 115-3 Rm Peak 128 0.9 1,820 2,170 77 4.32 0 -1,879 77 23.1 23.1 VAV -115 Zn Peak 1,177 8.2 16,739 19,954 711 - 17,278 711 23.2 23.2 VAV -115 Zn Block 1,177 8.2 16,722 19,938 711 - 17,278 711 23.2 23.2 116-1 Open office Rm Peak 600 3.0 8,481 9,653 376 4.48 0 -7,248 376 15.9 15.9 116 -2 Copy room Rm Peak 100 1.0 9,256 9,690 471 33.67 0 -5,224 471 4.2 4.2 VAV -116 Zn Peak 700 4.0 17,706 19,312 848 - 12,472 848 9.4 9.4 VAV -116 Zn Block 700 4.0 17,858 19,421 848 - 12,472 '848 ' 9.4 9.4 117 -1 Rm Peak 112 0.8 1,593 1,899 68 4.32 0 -1,644 68 23.1 23.1 117 -2 Rm Peak 360 2.5 5,120 6,103 217 4.32 0 -5,285 217 23.2 23.2 VAV -117 Zn Peak 472 3.3 6,713 8,002 285 -6,929 285 23.2 23.2 VAV -117 Zn Block 472 3.3 ' 6,706 7,995 285 -6,929 ' 285 23.2 23.2 118 -1 Rm Peak 119 0.8 1,692 2,017 72 4.32 0 -1,747 72 23.1 23.1 VAV -118 Zn Peak 119 0.8 1,692 2,017 72 -1,747 72 23.1 23.1 VAV -118 Zn Block 119 0.8 1,692 2,017 72 -1,747 72 23.1 23.1 119 -1 Rm Peak 291 2.0 4,138 4,934 '176 4.32 0 -4,272 176 23.2 23.2 119-2 Rm Peak 173 1.2 2,460 2,933 105 4.32 0 -2,540 105 23.2 23.2 119-3 Rm Peak 190 1.3 2,702 3,221 115 4.32 0 -2,789 115 23.2 23.2 VAV -119 Zn Peak 654 4.6 9,301 11,088 395 -9,601 395 23.2 23.2 VAV -119 Zn Block 654 4.6 9,292 11,078 395 -9,601 ' 395 23.2 23.2 120 -1 Conf Rm Rm Peak 368 10.0 7,169 11,076 220 4.28 0 - 15,769 220 90.8 90.8 VAV -120 Zn Peak 368 10.0 7,169 11,076 220 - 15,769 220 90.8 90.8 VAV -120 Zn Block 368 10.0 7,169 11,076 220 - 15,769 220 90.8 90.8 121 -1 Rm Peak 123 0.9 1,749 2,085 74 4.32 0 -1,806 74 23.1 23.1 121 -2 Rm Peak 346 1.0 7,026 7,417 338 6.98 0 -4,144 338 5.9 5.9 121 -3 Rm Peak 129 1.0 1,737 2,128 72 3.96 0 -1,978 72 28.0 28.0 VAV -121 Zn Peak 598 2.9 10,513 11,630 484 -7,928 484 11.8 11.8 VAV -121 Zn Block 598 2.9 10,502 11,620 484 -7,928 484 11.8 11.8 122 -1 Rm Peak 147 1.0 1,837 2,228 76 3.69 0 -2,015 76 26.3 26.3 122 -2 Rm Peak 244 3.0 10,427 11,729 501 14.67 0 -8,261 501 12.0 12.0 122 -3 Rm Peak 108 0.0 2,718 2,718 137 9.08 0 -1,114 137 0.0 0.0 122-4 Rm Peak 102. 1.0 1,587 1,978 65 4.54 0 -1,924 65 30.9 30.9 122 -5 Rm Peak 147 1.0 1,837 2,228 76 3.69 0 -2,015 76 26.3 26.3 VAV -122 Zn Peak 748 , 6.0 18,315 20,790 855 ,, - - 15,328 ,; 855 ; .14.0 14.0 -- This report does not display heating only systems. Project Name: Dataset Name: Gateway Building 7 West RTU Upgrade TRACE® 700 v6.1.2 calculated at 10:35 AM on 05/16/2008 C: \CDS \TRACE700 \Projects \738 -6215 Gateway Bldg7 Phase 2 \GATEWAY7- PH2.TRC Load /Airflow Summary Report Page 3 of 9 Coil Coil Space. VAV Main Coil Heating Floor Cooling Cooling Design Air Minimum Heating Fan Percent ASHRAE Area People Sensible Total Max SA Changes SA Sensible Max SA OA Std 62 - System Zone Room " _.. ._ _ ft'. # . - .Btu /h - . - - - -• Btu /h cfm - --- ach/hr - cfm - - - Btu /h . cfm -- Clg Htg OA Fraction VAV -122 Zn Block 748 6.0 18,568 20,912 855 - 15,328 855 14.0 14.0 201 -1P Rm Peak 328 2.3 7,391 8,287 330 7.19 0 -5,887 330 13.9 13.9 201 -2 Rm Peak 443 3.1 6,279 7,489 266 4.28 0 -6,486 266 23.3 23.3 VAV -201 Zn Peak 771 5.4 13,670 15,776 596 - 12,373 594 18.2 18.2 VAV -201 Zn Block 771 5.4 13,662 15,768 594 - 12,357 594 18.2 18.2 202 -1P Rm Peak 367 2.6 7,960 8,963 354 6.89 0 -6,461 354 14.5 14.5 202 -2 Rm Peak 237 1.7 3,359 4,007 142 4.28 0 -3,470 142 23.3 23.3 VAV -202 Zn Peak 604 4.2 11,320 12,970 496 -9,931 494 17.1 17.1 VAV -202 Zn Block 604 4.2 11,315 12,965 494 -9,917 494 17.1 17.1 203-1P Office Rm Peak 261 2.0 6,101 6,883 272 7.45 0 ' -5,006 272 14.7 - 14.7 . 203-2P Office Rm Peak 126 1.0 2,955 3,346 133 7.53 0 -2,476 133 15.1 15.1 203-3P Office Rm Peak 130 1.0 3,607 3,998 165 9.06 0 -2,737 165 12.1 12.1 203 -4P Office Rm Peak 291 4.0 8,764 10,327 381 9.35 0 -8,684 381 21.0 21.0 203-6 Breakroom Rm Peak 79 2.0 3,304 4,085 141 12.76 0 -3,941 141 28.3 28.3 VAV -203 Zn Peak 887 10.0 24,732 28,639 1,092 - 22,845 1,090 18.3 18.3 VAV -203 Zn Block 887 10.0 24,722 28,629 1,090 - 22,828 1,090 18.3 18.3 204 -1P Rm Peak 131 0.9 3,126 3,484 141 7.67 0 -2,422 141 13.0 13.0 204-2P Rm Peak 104 0.7 2,735 3,019 124 , 8.54 0 =2,026 124 , 11.7 11.7 204 -3P Rm Peak 158 1.1 3,522 3,954 157 7.10 0 -2,820 157 14.1 14.1 VAV -204 Zn Peak 393 2.7 9,383 10,456 422 -7,267 422 13.0 ' 13.0 VAV -204 Zn Block 393 2.7 9,381 10,455 422 -7,267 422 13.0 13.0 205-1P Rm Peak 222 1.6 5,072 5,679 227 7.31 0 -4,014 227 ' 13.7 ' . - 13.7 VAV -205 Zn Peak 222 1.6 5,072 5,679 227 -4,014 227 13.7 13.7 VAV -205 Zn Block 222 1.6 5,072 5,679 227 -4,014 227 13.7 13.7 206 -1P Rm Peak 250 1.7 8,381 9,140 399 11.39 0 -5,679 399 8.8 8.8 VAV -206 Zn Peak 250 1.7 8,381 9,140 399 -5,679 399 8.8 • 8.8 VAV -206 Zn Block 250 1.7 8,381 9,140 399 -5,679 399 8.8 8.8 207 -1P Rm Peak 148 1.0 5,552 5,917 273 13.15 0 . -3,659 273 7.6 7.6 207 -2P Rm Peak 142 1.0 5,467 5,817 269 13.51 0 -3,568 269 7.4 7.4 207 -3P Rm Peak 114 0.8 3,055 3,401 154 . 9.64 - 0 -2,363 154 10.4 . 10.4 VAV -207 Zn Peak 404 2.8 13,891 14,952 695 -9,590 695 8.1 8.1 VAV -207 Zn Block 404 2.8 14,209 15,205 695 -9,590 695 8.1 8.1 208-1P Rm Peak 114 0.8 5,054 5,335 249 15.61 0 -3,136 249 6.4 6.4 208 -2P Rm Peak 114 0.8 5,054 5,335 249 15.61 . 0 ' -3,136 249 6.4 6.4 208 -3P Rm Peak 146 1.0 5,738 6,181 289 14.15 0 -3,775 289 7.1 7.1 VAV -208 • Zn Peak 374 2.6 15,612 16,618 787 - 10,047 787 6.6 6.6 VAV -208 Zn Block 374 2.6 16,023 16,945 787 - 10,047 787 6.6 6.6 209-1P Rm Peak 94 0.7 2,749 3,007 183 13.90 . 0 -2,404 183 7.2 7.2 209 -2P Rm Peak 97 0.7 2,839 3,105 190 14.02 0 -2,494 190 7.1 7.1 209 -3P Rm Peak 104 0.7 4,415 4,731 214 14.67 0 -2,751 214 6.8 • 6.8 209-4P Rm Peak 112 0.8 5,893 6,150 291 18.55 0 -3,456 291 5.4 5.4 209-5P Rm Peak 169 1.2 8,753 9,141 431 18.23 0 -5,154 431 5.5 5.5 209 -6 Rm Peak 123 0.9 1,743 2,079 74 ' 4.28 0 -1,801 74 23.3 23.3 ' This report does not display heating only systems. Project Name: Dataset Name: Gateway Building 7 West RTU Upgrade TRACE® 700 v6.1.2 calculated at 10:35 AM on 05/16/2008 C: \CDS \TRACE700 \Projects \738 -6215 Gateway BIdg7 Phase 2 \GATEWAY7- PH2.TRC Load /Airflow Summary Report Page 4 of 9 Coil Coil Space VAV Main Coil Heating Floor Cooling Cooling Design Air Minimum Heating Fan Percent ASHRAE Area People Sensible Total Max SA Changes SA Sensible Max SA OA Std 62 • _.System _Zone Room ". - ft' - • # Btu /h - Btu /h • cfm- achlhr cfm Btu /h - - cfm Clg • OA Fraction VAV -209 Zn Peak 699 4.9 26,762 28,582 1,383 - 18,059 1,302 7.5 7.5 VAV -209 Zn Block 699 4.9 24,481 26,552 1,302 - 17,399 1,302 7.5 7.5 210-1P Rm Peak 141 1.0 6,254 6,578 307 15.54 0 -3,868 307 6.4 6.4 210 -2P Rm Peak 112 0.8 5,893 6,150 291 18.55 0 -3,456 291 5.4 5.4 VAV -210 Zn Peak 253 1.8 12,147 12,728 598 -7,324 598 5.9 5.9 VAV -210 Zn Block 253 1.8 12,143 12,724 598 -7,324 598 5.9 5.9 211 -1P Rm Peak 133 1.0 5,993 6,321 294 15.79 0 -3,785 294 6.8 6.8 211 -2P Rm Peak 125 1.0 3,977 4,263 187 10.67 0 -2,913 187 10.7 10.7 211 -3P Rm Peak 139 1.0 7,142 7,427 349 17.92 0 - 4,228 349 5.7 5.7 211-4 Conf Rm Rm Peak 125 3.0 3,412 4,584 131 7.48 0 -5,257 131 45.8 45.8 211 -5 Rm Peak 367 1.0 6,994 7,385 335 6.52 0 -4,118 335 6.0 . 6.0 211 -6 Rm Peak 143 1.0 2,027 2,418 86 4.28 0 -2,094 86 23.3 23.3 VAV -211 Zn Peak 1,032 8.0 30,049 32,901 1,381 - 22,394 1,365 11.7 11.7 VAV -211 Zn Block 1,032 8.0 27,651 31,039 1,365 - 22,264 1,365 11.7 11.7 212 -1P Conf Rm Rm Peak 182 6.0 7,698 9,217 365 14.32 0 - 11,348 365 32.9 32.9 212 -2 Rm Peak 305 2.1 4,323 5,156 183 4.28 0 -4,466 183 23.3 23.3 212 -3 Rm Peak 170 1.2 2,410 2,874 102 4.28 0 -2,489 ' 102 23.3 23.3 VAV -212 Zn Peak 657 9.3 13,597 16,414 649 - 18,303 638 29.2 29.2 VAV -212 Zn Block 657 9.3 14,037 16,397 638 - 18,207 638 - 29.2 29.2 213 -1 Rm Peak 132 0.9 1,871 2,232 79 4.28 0 -1,933 79 23.3 23.3 213 -2 Rm Peak ' 516 3.6 7,314 8,723 309 4.28 0 -7,555 309 23.3 23.3 VAV -213 Zn Peak 648 4.5 9,185 10,955 388 -9,488 388 23.3 23.3 VAV -213 Zn Block 648 4.5 9,175 10,945 388 -9,488 388 23.3 23.3 214 -1 Open office Rm Peak 255 2.0 3,447 4,228 141 3.95 0 -3,941 141 28.3 28.3 VAV -214 Zn Peak 255 2.0 3,447 4,228 141 -3,941 141 28.3 28.3 VAV -214 Zn Block 255 2.0 3,447 4,228 141 -3,941 141 28.3 28.3 215-1 Open office Rm Peak 519 2.0 4,909 5,690 206 2.84 0 -4,469 206 19.4 *• 19.4 215-2 Storage + hallway Rm Peak 215 0.0 4,160 4,160 209 6.95 0 -1,697 209 0.0 0.0 VAV -215 Zn Peak 734 2.0 9,069 9,850 415 -6,166 415 9.6 9.6 VAV -215 Zn Block 734 2.0 9,078 9,859 415 -6,161 415 9.6 9.6 216-1 Testing Rm Rm Peak 675 19.0 24,089 33,287 968 10.25 0 - 34,421 968 39.2 39.2 VAV -216 Zn Peak 675 19.0 24,089 33,287 968 - 34,421 968 39.2 39.2 VAV -216 Zn Block 675 19.0 24,089 33,287 968 - 34,421 968 39.2 '39.2 217 -1 Open office Rm Peak 335 5.0 7,604 9,557 313 6.67 0 -9,529 313 32.0 32.0 217 -2 Office Rm Peak 108 1.0 1,615 2,006 66 4.35 0 . -1,932 66 30.4 30.4 217 -3 Server Rm Rm Peak 125 1.0 7,444 7,835 369 21.07 0 -4,391 369 5.4 5.4 217-4 Rm Peak 125 0.9 1,772 2,113 75 4.28 0 -1,830 75 23.3 23.3 VAV -217 Zn Peak 693 7.9 18,435 21,511 822 - 17,681 822 19.2 19.2 VAV -217 Zn Block 693 7.9 18,418 21,494 822 - 17,681 822 19.2 19.2 218 -1 Rm Peak 448 3.1 6,350 7,574 269 4.28 0 -6,559 269 23.3 23.3 VAV -218 Zn Peak 448 3.1 6,350 7,574 269 -6,559 269 23.3 23.3 VAV -218 Zn Block 448 3.1 6,350 7,574 269 -6,559 269 23.3 23.3 219 -1 Rm Peak , 198 1.4 .2,806. .:. 3,347 x ,119 4.28 .0 : . . •..- 2,899.,.: 119 -23.3 - 23.3 " This report does not display heating only systems. Project Name: Dataset Name: Gateway Building 7 West RTU Upgrade TRACE® 700 v6.1.2 calculated at 10:35 AM on 05/16/2008 C: \CDS \TRACE700 \Projects 1738 -6215 Gateway Bldg7 Phase 2 \GATEWAY7- PH2.TRC Load /Airflow Summary Report Page 5 of 9 Coil Coil Space VAV Main Coil Heating Floor Cooling Cooling Design Air Minimum Heating Fan Percent ASHRAE Area People Sensible Total Max SA Changes SA Sensible Max SA OA Std 62 • System Zone Room " ft' # Btu /h- _ .- Btu /h cfm .achlhr . cfm Btu /h - - - cfm - Clg -Htg OA Fraction VAV -219 Zn Peak 198 1.4 2,806 3,347 119 -2,899 119 23.3 23.3 VAV -219 Zn Block 198 1.4 2,806 3,347 119 -2,899 119 23.3 23.3 220 -1 Rm Peak 95 0.7 1,347 1,606 57 4.28 0 -1,391 57 23.3 23.3 220-2 Rm Peak 628 4.4 8,901 10,617 376 4.28 0 -9,195 376 23.3 23.3 VAV -220 Zn Peak 723 5.1 10,248 12,223 433 - 10,586 433 23.3 23.3 VAV -220 Zn Block 723 5.1 10,237 12,212 433 - 10,586 433 23.3 23.3 221 -1 Rm Peak 110 0.8 1,559 1,860 66 4.28 0 -1,611 66 23.3 23.3 221 -2 Rm Peak 456 3.2 6,463 7,709 273 4.28 0 -6,677 273 23.3 23.3 VAV -221 Zn Peak 566 4.0 8,022 9,569 339 -8,287 339 23.3 23.3 VAV -221 Zn Block 566 4.0 8,014 9,560 339 -8,287 339 23.3 23.3 RTU 50 TON EAST ZONE Sys Peak 27,479 277.8 664,662 773,770 29,707 - 623,246 27,392 20.0 20.0 RTU 50 TON EAST ZONE Sys Block 27,479 277.8 611,457 730,590 27,392 419,105 27,392 20.0 20.0 NO CONTROL -101 Lab 3 Rm Peak 866 28.0 32,688 43,653 1,491 12.30 0 - 42,146 1,491 28.2 28.2 NO CONTROL -102 Open office Rm Peak 164 3.0 5,933 6,683 262 11.40 0 -6,449 262 22.9 22.9 NO CONTROL -103 Open office Rm Peak 218 4.0 9,602 10,603 436 14.30 0 -9,362 436 18.3 18.3 NO CONTROL -104 Open office Rm Peak 368 4.0 11,797 12,797 542 10.52 0 - 10,289 542 14.8 14.8 NO CONTROL -105 Storage Rm Peak 180 0.0 820 956 29 1.14 0 -1,249 29 50.1 50.1 NO CONTROL -203 Theory 5 Rm Peak 168 6.0 3,723 6,072 127 5.42 0 -7,349 127 70.6 70.6 NO CONTROL -204 Corridor Rm Peak 719 0.0 6,414 6,558 287 2.85 0 -6,498 287 20.0 20.0 123-1P Lab 2 North Rm Peak 857 29.0 43,182 54,539 2,053 17.11 0 - 48,110 2,053 21.2 21.2 123 -2 Rm Peak 761 0.0 2,684 2,684 122 1.14 0 -1,064 122 0.0 0.0 VAV -123 Zn Peak 1,618 29.0 45,866 57,222 2,175 - 49,174. 2,171 20.0 20.0 VAV -123 Zn Block 1,618 29.0 45,754 57,111 2,171 - 49,137 2,171 20.0 20.0 124 -1P Lab 2 South Rm Peak 834 29.0 43,816 55,172 2,086 17.86 0 - 48,393 2,086 20.9 20.9 VAV -124 Zn Peak 834 29.0 43,816 55,172 2,086 - 48,393 2,086 20.9 20.9 VAV -124 Zn Block 834 29.0 43,816 55,172 2,086 - 48,393 2,086 20.9 20.9 125-1P Lab 1 Rm Peak 866 28.0 41,577 52,541 1,977 16.31 0 - 46,405 1,977 21.2 21.2 VAV -125 Zn Peak 866 28.0 41,577 52,541 1,977 - 46,405 1,977 21.2 ` 21.2 VAV -125 Zn Block 866 28.0 41,577 52,541 1,977 - 46,405 1,977 21.2 21.2 126-1P Conf Rm Rm Peak 94 4.0 7,374 8,932 363 27.62 0 -8,724 363 22.0 22.0 126 -2P Lobby Rm Peak 652 6.0 19,114 21,151 949 10.39 0 - 16,619 949 12.6 12.6 VAV -126 Zn Peak 746 10.0 26,343 29,938 1,312 - 25,343 1,312 15.2 15.2 VAV -126 Zn Block 746 10.0 26,588 29,983 1,312 - 25,343 1,312 15.2 15.2 127 -1P Open office Rm Peak 157 3.0 10,658 11,827 550 25.02 0 -8,971 550 10.9 10.9 127 -2P Conf Rm Rm Peak 104 4.0 6,826 7,958 316 21.68 0 -8,305 316 25.3 25.3 127 -3P Office Rm Peak 223 1.0 9,022 9,305 447 14.33 0 - 5,303 447 4.5 4.5 VAV -127 Zn Peak 484 8.0 26,013 28,597 1,313 - 22,580 1,307 12.2 12.2 VAV -127 Zn Block 484 8.0 27,211 29,476 1,307 - 22,526 1,307 12.2 12.2 128-1P Office Rm Peak 241 1.0 9,720 10,067 499 14.79 0 -5,755 499 4.0 4.0 VAV -128 Zn Peak 241 1.0 9,720 10,067 499 -5,755 499 4.0 4.0 VAV -128 Zn Block 241 1.0 9,720 10,067 499 -5,755 499 4.0 4.0 129 -1P Office Rm Peak 183 1.0 7,897 8,147 385 15.01 0 -4,753 385 5.2 . 5.2 VAV -129 Zn Peak 183 1.0 7,897 8,147 385 -4,753 385 5.2 5.2 "This report does not display heating only systems. Project Name: Dataset Name: Gateway Building 7 West RTU Upgrade TRACE® 700 v6.1.2 calculated at 10:35 AM on 05/16/2008 C: \CDS \TRACE700\Projects \738 -6215 Gateway Bldg7 Phase 2 \GATEWAY7- PH2.TRC Load /Airflow Summary Report Page 6 of 9 Coil Coil Space VAV Main Coil Heating Floor Cooling Cooling Design Air Minimum Heating Fan Percent ASHRAE Area People Sensible Total Max SA Changes SA Sensible Max SA OA Std 62 • System Zone Room " fN - .... # _ Btu /h.. _ .._ Btu /h - . _ cfm - - - - -. ach/hr•- - cfm - Btu /h - - - cfm . - • - ° --• Htg OA Fraction VAV -129 Zn Block 183 1.0 7,897 8,147 385 -4,753 385 5.2 5.2 130 -1P Office Rm Peak 185 1.0 5,948 6,198 284 10.96 0 -3,872 284 7.0 7.0 130 -2P Office Rm Peak 122 1.0 6,241 6,491 303 17.73 0 -4,037 303 6.6 6.6 130 -3P Office Rm Peak 122 1.0 5,624 5,874 271 15.87 0 -3,758 271 7.4 7.4 130-4P Office Rm Peak 185 1.0 4,675 4,958 224 8.64 0 -3,344 224 8.9 8.9 VAV -130 Zn Peak 614 4.0 22,493 23,526 1,081 - 15,011 1,072 7.5 7.5 VAV -130 Zn Block 614 4.0 22,401 23,401 1,072 - 14,924 1,072 7.5 7.5 131 -1P Student Lounge Rm Peak 1,931 12.0 28,739 32,884 1,292 4.78 0 - 27,934 1,292 18.6 18.6 VAV -131 Zn Peak 1,931 12.0 28,739 32,884 1,292 - 27,934 1,292 18.6 18.6 VAV -131 Zn Block 1,931 12.0 28,739 32,884 1,292 - 27,934 1,292 18.6 18.6 132-1P Office Rm Peak 134 1.0 5,426 5,676 260 13.85 0 -3,661 260 7.7 7.7 132 -2 Office Rm Peak 143 1.0 1,763 2,152 75 3.72 0 -2,038 75 26.8 26.8 VAV -132 Zn Peak 277 2.0 7,021 7,660 334 -5,699 334 12.0 12.0 VAV -132 Zn Block 277 2.0 7,228 7,728 334 -5,699 334 12.0 12.0 133-1P Theory 1 Rm Peak 854 28.0 29,276 37,327 1,278 10.69 0 - 40,281 1,278 32.9 32.9 VAV -133 Zn Peak 854 28.0 29,276 37,327 1,278 - 40,281 1,278 32.9 32.9 VAV -133 Zn Block 854 28.0 29,276 37,327 1,278 - 40,281 1,278 32.9 32.9 134 -1P Lab 4 Rm Peak 855 20.0 33,261 39,012 1,545 12.91 0 - 34,310 1,545 19.4 19.4 VAV -134 Zn Peak 855 20.0 33,261 39,012 1,545 - 34,310 1,545 19.4 19.4 VAV -134 Zn Block 855 20.0 33,261 39,012 1,545 - 34,310 1,545 19.4 19.4 135-1 Office Rm Peak 105 1.0 1,559 1,948 65 4.43 • 0 -1,956 .. 65 30.7 • 30.7 135-2 Storage Rm Peak 276 0.0 1,257 1,465 44 1.14 0 - 1,915 44 50.1 50.1 135-3 Office Rm Peak 178 1.0 1,996 2,342 83 3.34 0 -2,113 83 24.1 24.1 VAV -135 Zn Peak 559 2.0 4,843 5,785 192 -5,984 192 32.3 32.3 VAV -135 Zn Block 559 2.0 4,762 5,748 192 - -5,983 192 32.3 .32.3 136-1 Open office Rm Peak 298 3.0 5,889 7,056 261 6.25 0 -6,440 261 23.0 23.0 136-2 Testing Rm Peak 199 3.0 4,057 5,224 171 6.14 0 -5,655 171 .35.1 35.1 136 -3 Storage Rm Peak 90 0.0 410 478 14 1.14 0 -625 14 50.1 50.1 VAV -136 Zn Peak 587 6.0 10,356 12,757 446 - 12,719 446. 28.5 28.5 VAV -136 Zn Block 587 6.0 10,344 12,744 446 - 12,718 446 28.5 28.5 137 -1 Conf Rm Rm Peak 102 4.0 3,035 4,590 . 103 7.22 0 -6,443 103 77.6 77.6 137 -2 Copy Rm Rm Peak 209 1.0 4,985 5,373 243 8.32 0 -3,517 243 8.2 8.2 137 -3 Office Rm Peak 146 1.0 1,779 2,168 75 3.68 0 -2,044 75 26.6 26.6 VAV -137 Zn Peak 457 6.0 9,799 12,132 422 - 12,005 422 28.4 28.4 VAV -137 Zn Block 457 6.0 9,787 12,120 422 - 12,005 422 28.4 28.4 222 -1P South entrance Rm Peak 500 0.0 14,991 15,095 1,101 15.72 0 - 11,370 1,101 2.3 2.3 222 -2 Corridor Rm Peak 1,387 0.0 6,498 7,304 221 1.14 0 -9,625 221 50.1 50.1 VAV -222 Zn Peak 1,887 0.0 20,515 21,425 1,322 - 20,995 1,307 10.4 10.4 VAV -222 Zn Block 1,887 0.0 20,263 20,828 1,307 - 20,864 1,307 10.4 10.4 223 -1P Lab 9 Rm Peak 875 32.0 25,902 38,433 1,071 8.74 0 - 42,621 1,071 44.8 44.8 VAV -223 Zn Peak 875 32.0 25,902 38,433 1,071 -42,621 1,071 44.8 44.8 VAV -223 Zn Block 875 32.0 25,902 38,433 1,071 - 42,621 1,071 44.8 44.8 224 -1P Lab 7 Rm Peak 858 17.0 24,401 31,058 1,159 . 9.65 0 - 27,813...- 1,159..22.0 .22.0 "This report does not display heating only systems. Project Name: Dataset Name: Gateway Building 7 West RTU Upgrade TRACE® 700 v6.1.2 calculated at 10:35 AM on 05/16/2008 C:1CDS\TRACE7001Projects1738 -6215 Gateway Bldg7 Phase 21GATEWAY7- PH2.TRC Load /Airflow Summary Report Page 7 of 9 System Zone Room " VAV -224 VAV -224 225-1P Lab 5 VAV -225 VAV -225 226 -1 P Open seating + breakroom VAV -226 VAV -226 227 -1 P Instructors VAV -227 VAV -227 228-1P Instructors VAV -228 VAV -228 233-1P Theory 4 VAV -233 VAV -233 234-1 Theory 5 VAV -234 VAV -234 235-1P Office 235-2P Theory 6 per 235 -3P Office VAV -235 VAV -235 236 -1P Office 236 -2P Office 236 -3P Office 236-4P Office VAV -236 VAV -236 237 -1P Office 237 -2P Conf rm 237 -3 Reception 237-4 Breakmi 237 -5 Open office VAV -237 VAV -237 238 -1 Open office VAV -238 VAV -238 239-1 Mens toilet 239 -2 Womens toilet "This report Project Name: Dataset Name: does not display heating only systems. Zn Peak Zn Block Rm Peak Zn Peak Zn Block Rm Peak Zn Peak Zn Block Rm Peak Zn Peak Zn Block Rm Peak Zn Peak Zn Block Rm Peak Zn Peak Zn Block Rm Peak Zn Peak Zn Block Rm Peak Rm Peak Rm Peak Zn Peak Zn Block Rm Peak Rm Peak Rm Peak Rm Peak Zn Peak Zn Block Rm Peak Rm Peak Rm Peak Rm Peak Rm Peak Zn Peak Zn Block Rm Peak Zn Peak Zn Block Rm Peak Rm Peak Floor Area f 858 858 858 858 858 858 858 858 553 553 553 694 694 694 492 492 492 405 405 405 143 234 173 550 550 160 143 169 168 640 640 145 208 566 194 423 1,536 1,536 584 584 584 306 267 People 17.0 17.0 21.0 21.0 21.0 9.0 9.0 9.0 9.0 9.0 9.0 15.0 15.0 15.0 23.0 23.0 23.0 13.0 13.0 13.0 1.0 13.0 1.0_ 15.0 15.0 1.0 1.0 1.0 1.0 4.0 4.0 1.0 8.0 2.0 3.0 3.0 17.0 17.0 4.1 4.1 4.1 0.0 0.0 Coil Cooling Sensible Btu /h_ 24,401 24,401 25,643 25,643 25,643 16,977 16,977 16,977 16,245 16,245 16,245 29,916 29,916 29,916 18,245 18,245 18,245 9,765 9,765 9,765 5,616 14,903 5,793 26,312 26,287 7,671 4,696 • 4,343 3,106 19,541 19,766 3,615 9,461 5,293 4,561 5,961 28,891 28,876 8,229 8,229 8,229 1,433 1,251 Coil Cooling Total Btu /h __ 31,058 31,058 33,866 33,866 33,866 20,477 20,477 20,477 19,744 19,744 19,744 35,590 35,590 35,590 25,771 25,771 25,771 14,855 14,855 14,855 5,866 18,641 6,043 30,550 30,525 7,921 4,946 4,688 3,451 20,732 20,766 3,960 12,225 5,984 5,597 6,982 34,748 34,733 9,640 9,640 9,640 1,611 1,406 Space Design Max SA ,cfm 1,159 1,159 1,184 1,184 1,184 821 821 821 722 722 722 1,387 1,387 1,387 744 744 744 362 362 362 268 675 274 1,217 1,182 372 218 200 138 928 926 165 367 224 189 252 1,197 1,195 348 348 348 49 43 VAV Main Coil Air Minimum Heating Changes SA Sensible -- achlhr -. - cfm _.Btu /h - 27,813 - 27,813 9.85 0 - 32,181 - 32,181 - 32,181 6.84 0 - 19,659 - 19,659 - 19,659 9.32 0 - 18,788 - 18,788 - 18,788 14.27 0 - 32,920 - 32,920 - 32,920 10.80 0 - 30,408 - 30,408 - 30,408 6.39 0 - 16,679 - 16,679 - 16,679 13.36 0 -3,728 20.59 0 - 19,412 11.33 0 -3,789 - 26,930 - 26,623 16.61 0 -4,643 10.91 0 -3,297 8.47 . 0 -3,139 5.86 0 -2,592 - 13,672 - 13,646 8.11 0 -2,826 12.62 0 - 14,300 2.83 0 -4,732 6.94 0 -5,807 4.26 0 -6,306 - 33,971 - 33,956 4.26 0 -8,706 -8,706 -8,706 1.14 0 -2,123 1.14 0 -1,853 Heating Fan Percent Max SA OA - cfm - -- -- Clg.. Htg 1,159 1,159 1,184 1,184 1,184 821 821 821 722 722 722 1,387 1,387 1,387 744 744 744 362 362 • 362 268 675 274 1,182 1,182 372 218 200 138 926 926 165 . 367 . 224 189 252 1,195 1,195 348 348 348 49 43 22.0 22.0 26.6 26.6 26.6 21.9 21.9 21.9 24.9 24.9 24.9 21.6 21.6 21.6 46.4 46.4 46.4 53.8 53.8 53.8 7.5 28.9 7.3 19.9 19.9 5.4 9.2 10.0 14.5 8.6 8.6 12.2 43.5 17.9 31.8 23.5 28.4 28.4 23.5 23.5 23.5 50.1 50.1 22.0 22.0 26.6 26.6 26.6 21.9 21.9 21.9 24.9 24.9 24.9 21.6 21.6 21.6 46.4 46.4 46.4 53.8 53.8 53.8 7.5 28.9 7.3 19.9 19.9 5.4 9.2 10.0 14.5 8.6 8.6 12.2 43.5 17.9 31.8 23.5 28.4 28.4 23.5 23.5 23.5 50.1 50.1 ASHRAE Std 62 • OA Fraction Gateway Building 7 West RTU Upgrade TRACE® 700 v6.1.2 calculated at 10:35 AM on 05/16/2008 C: \CDS \TRACE700 \Projects \738 -6215 Gateway BIdg7 Phase 2 \GATEWAY7- PH2.TRC Load /Airflow Summary Report Page 8 of 9 Coll Coil Space VAV Main Coil Heating Floor Cooling Cooling Design Air Minimum Heating Fan Percent ASHRAE Area People Sensible Total Max SA Changes SA Sensible Max SA OA Std 62 • System Zone Room " _ .... __ .. -__ ..___ _. iN- - -_ -.... q _ _ _ Btu /h- - -- Btu /h- - -cfm- achlhr --- -cfm - - - -- -- Btu /h - --- cfm- . - CIg - • Htg OA Fraction 239-3 Office Rm Peak 215 1.0 2,195 2,541 91 3.04 0 -2,186 91 21.9 21.9 239-4 Office Rm Peak 201 1.0 2,118 2,464 88 3.13 0 -2,156 88 22.7 22.7 239-5 Theory 6 int Rm Peak 676 36.0 22,644 36,742 790 8.35 0 -44,318 790 68.4 68.4 VAV -239 Zn Peak 1,665 38.0 29,772 44,893 1,061 - 52,636 1,060 59.0 59.0 VAV -239 Zn Block 1,665 38.0 29,434 44,742 1,060 - 52,632 1,060 59.0 59.0 240 -1 Corridor Rm Peak 377 0.0 1,766 1,985 60 1.14 0 -2,616 60 50.1 50.1 240 -2 Theory 4 Rm Peak 126 6.0 3,470 5,820 116 6.55 0 -7,246 116 77.8 77.8 VAV -240 Zn Peak 503 6.0 5,282 7,851 176 -9,862 176 68.3 68.3 VAV -240 Zn Block 503 6.0 5,189 7,823 176 -9,862 176 68.3 68.3 241 -1 Open office Rm Peak 245 4.0 6,056 7,438 251 7.31 0 -7,736 251 31.9 31.9 241 -2 Corridor Rm Peak 587 0.0 2,750 3,091 94 1.14 0 - 4,073 94 50.1 50.1 241 -3 Storage Rm Peak 118 0.0 553 621 19 1.14 0 -819 19 50.1 50.1 241-4 Storage Rm Peak 76 0.0 356 400 12 1.14 0 -527 12 50.1 50.1 241 -5 Server Rm Rm Peak 69 0.0 6,355 6,407 323 33.39 0 -3,207 323 1.7 1.7 VAV -241 Zn Peak 1,095 4.0 16,285 18,173 698 - 16,363 698 21.2 21.2 VAV -241 Zn Block 1,095 4.0 15,815 18,013 698 - 16,360 698 21.2 21.2 RTU 60 TON WEST ZONE Sys Peak 27,842. 458.0 747,168 915,148 "33,909 - 843,889 30,307 26.1 26.1 RTU 60 TON WEST ZONE Sys Block 27,842 458.0 696,048 861,519 30,307 - 834,673 30,307 26.1 26.1 " This report does not display heating only systems. Project Name: Gateway Building 7 West RTU Upgrade TRACE® 700 v6.1.2 calculated at 10:35 AM on 05/16/2008 Dataset Name: C: \CDS \TRACE7001Projects1738 -6215 Gateway BIdg7 Phase 2\GATEWAY7- PH2.TRC Load /Airflow Summary Report Page 9 of 9 DRAWING SHEET INDEX NAME TITLE NAME TITLE F001 SCHEDULES - FITTING F101 NORTH SITE PLAN - FITIING F102 SOUTH SITE PLAN - FITIING F111 LEVEL 1 SOUTH WING - FITTING F112 LEVEL 1 CENTRAL CORE - FITTING F113 LEVEL 1 WEST WING - FITTING F121 LEVEL 2 SOUTH WING - FITTING F122 LEVEL 2 CENTRAL CORE - FITTING F123 LEVEL 2 WEST WING - FITTING F131 LEVEL 3 THRU 7 SOUTH WING - FITTING F132 LEVEL 3 THRU 7 CENTRAL CORE - FITTING F133 LEVEL 3 THRU 7 WEST WING - FITTING F181 LEVEL 8 SOUTH WING - FITTING F182 LEVEL 8 CENTRAL CORE - FITTING F183 LEVEL 8 WEST WING - FITTING F191 LEVEL 9 SOUTH WING - FITTING F192 LEVEL 9 CENTRAL CORE - FITTING F193 LEVEL 9 WEST WING - FITTING F6.01 DETAILS - FITTING F6.02 DETAILS - FITTING Project Name: Dataset Name: Location: Building Owner: Program User: Company: Comments: Cooling Design Period: Peak Hour Override: Daylight Savings Period: Summer Period: Cooling Methodology: Heating Methodology: Infiltration Methodology: Outside Film Methodology: Terrain Methodology: Room Circ Rate: Wall Load To Plenum: Building Orientation: Simulation Hours: Calendar Code: Energy Simulation Period: Gateway Building 7 West RTU Upgrade C: \CDS \TRACE700 \Projects \738 -6215 Gateway Bldg7 Phase 2 \GATEWAY7- PH2.TRC 12720 Gateway Dr, Tukwila, WA RREEF Chris Lee MacDonald Miller Facility Solutions Replace West 60 ton RTU and replace existing VVT boxes with new VVT system using Nailor squeezeboxes This file is a complete load profile for both floors of the entire building 7 January thru December 0 CLTD -CLF (ASHRAE TFM) UATD Vary with wind speed Vary with wind speed Center of a large city Medium YES 0 degrees from north Reduced year Standard (1978) January thru December Entered Values TRACE® 700 version 6.1.2 By MacDonald - Miller Project Name: Gateway Building 7 West RTU Upgrade Dataset Name: C: \CDS \TRACE700 \Projects \738 -6215 Gateway Bldg7 Phase 2 \GATEWAY7- PH2.TRC Location: Summer Design Dry Bulb: Summer Design Wet Bulb: Winter Design Dry Bulb: Summer Clearness Number: Winter Clearness Number: Summer Ground Reflectance: Winter Ground Reflectance: Force VAV Min => Nominal Ventilation at Design: Allow Energy Recovery/Transfer at Design: Retest Design Peaks: Calculate Building Block Loads: Seattle, Washington 85.00 °F 67.00 °F 24.00 °F 0.95 0.95 0.20 0.20 Carbon Dioxide Level: 400 ppm No No Yes No TRACE® 700 v6.1.2 Entered Values - Project Information 11 -03 -2008 CHRIS LEE 7717 DETROIT AV SW SEATTLE WA 98106 RE: Permit No. M08 -154 12720 GATEWAY DR TUKW Dear Permit Holder: Thank you for your cooperation in this matter. Sincerely, xc: fer Marshall, it Technician Permit File No. M08 -154 Cif of f 7'ulcwlla Jim Haggerton, Mayor Department of Community Development Jack Pace, Director In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or fmal inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 12/03/2008 , your permit will become null and void and any further work on the project will require a new permit and associated fees. 6300 Southcenter Boulevard, Suite #100 0 Tukwila, Washington 98188 0 Phone: 206 - 431 -3670 0 Fax: 206 - 431 :3665 DEPARTMENTS: g Division (/ if Public Works Complete Comments: Documents/routing slip.doc 2-28-02 • PERMIT COORD COPY • PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M08-154 DATE: 05-28-08 PROJECT NAME: GATEWAY BUILDING 7 SITE ADDRESS: 12720 GATEWAY DR X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued ONO (11/0 Fire revention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete n TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved I Approved with Conditions Notation: REVIEWER'S INITIALS: El DATE: DATE: Planning Division Permit Coordinator n DUE DATE: 05-29-08 Not Applicable ,Permit Center (lie Only ' • ; • '• • . ' :• INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: No further Review Required DUE DATE: 06-26-08 Not Approved (attach comments) n Permit Center Use'Only • • , • CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: License Information License MACDOFS980RU Licensee Name MACDONALD/MILLER FAC SOL INC Licensee Type CONSTRUCTION CONTRACTOR UBI 602254260 Ind. Ins. Account Id CHIEF OPERATING OFFICER Business Type CORPORATION Address 1 PO BOX 47983 Address 2 City SEATTLE County KING State WA Zip 98106 Phone 2067684180 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 12/31/2002 Expiration Date 12/31/2008 Suspend Date Separation Date Parent Company Previous License DIVCOI *988RC Next License Associated License Business Owner Information Name Role Effective Date Expiration Date TURLEY, DOUGLAS CHIEF EXECUTIVE OFFICER 02/13/2008 TURLEY, DOUGLAS CHIEF OPERATING OFFICER 02/13/2008 SIGMUND, FREDRIC PRESIDENT 12/31/2002 HACK, RICHARD SECRETARY 02/13/2008 KOPET, TYLER TREASURER 12/31/2002 LOVELY, STEVE Look Up a Contractor, Electrician or Plumber License Detail • Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. 1 Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= MACDOFS980RU 06/06/2008 FLOOR 1 - SINGLE DUCT VVT BOX SCHEDULE FLOOR 2 - SINGLE DUCT VVT BOX SCHEDULE UNIT NO. MFG & MODEL' NO. INLET SIZE (IN) VALVE CFM CONTROLS NOTES MAX MIN LOCATION* VVT -201 NAILOR 3001 12 320 160 RIGHT REBAL, EXISTING, 1,2,4 VVT -202 NAILOR3001 12 370 110 LEFT EXISTING, 1,2,4 VVT -203 NAILOR3001 12 990 330 RIGHT EXISTING, 1,2,4 VVT -204 NAILOR 3001 12 300 90 LEFT EXISTING, 1,2,4 VVT -205 NAILOR 3001 10 170 50 LEFT EXISTING, 1,2,4 WT-206 NOT USED - - - - NOT USED VVT -207 NAILOR 3001 10 510 150 RIGHT EXISTING, 1,2,4 VVT -208 I NAILOR3001 12 570 170 LEFT EXISTING, 1,2,4 WT -209 NAILOR3001 14 1020 290 RIGHT EXISTING, 1,2,4 VVT -210 NAILOR 3001 12 440 130 RIGHT EXISTING, 1,2,4 WT -211 NAILOR3001 14 1030 260 RIGHT EXISTING, 1,2,4 VVT -212 NAILOR 3001 ' 12 490 190 LEFT EXISTING, 1,2,4 VVT -213 NAILOR 3001 12 270 80 LEFT EXISTING, 1,2,4 VVT -214 NAILOR 3001 10 390 210 LEFT EXISTING, 1,2,4 VVT -215 NAILOR3001 12 400 260 LEFT EXISTING, 1,2,4 VVT -216 NAILOR 3001 12 680 90 RIGHT EXISTING, 1,2,4 WT-217 NAILOR 3001 12 490 1 330 LEFT EXISTING, 1,2,4 WT-218 NAILOR 3001 12 200 60 LEFT EXISTING, 1,2,4 VVT -219 NAILOR 3001 12 90 30 RIGHT EXISTING, 1,2,4 VVT -220 NAILOR3001 12 320 100 LEFT EXISTING, 1,2,4 WT-221 NAILOR 3001 12 260 80 RIGHT EXISTING, 1,2,4 12 550 170 RIGHT EXISTING, 1,2,4 VVT -222 METAL INDUSTRIES 598 D 12 900 330 RIGHT NEW, REPLACE EXISTING WT, 1,3,5,6 VVT -223 METAL INDUSTRIES 598 D 12 1040 330 RIGHT NEW, REPLACE EXISTING VVT, 1,3,5,6 WT-224 METAL INDUSTRIES 598 D 12 1120 330 RIGHT NEW, REPLACE EXISTING VVT, 1,3,5,6 VVT -225 METAL INDUSTRIES 598 D 12 1160 330 RIGHT NEW, REPLACE EXISTING VVT, 1,3,5,6 VVT -226 METAL INDUSTRIES 598 C 10 800 210 RIGHT NEW, REPLACE EXISTING WT, 1,3,5,6 WT -227 METAL INDUSTRIES 598 D 12 1040 330 RIGHT NEW, REPLACE EXISTING VVT, 1,3,5,6 WT -228 METAL INDUSTRIES 598 D 12 1040 330 RIGHT NEW, REPLACE EXISTING VAT, 1,3,5,6 WT -229 METAL INDUSTRIES 598 E 14 810 400 RIGHT NEW, REPLACE EXISTING WIT, 1,3,5,6 WT -230 METAL INDUSTRIES 598 F 16 1220 630 RIGHT NEW, REPLACE EXISTING Wr, 1,3,5,6 WT -231 METAL INDUSTRIES 598 F 16 ' 2000 630 RIGHT NEW, REPLACE EXISTING VVT, 1,3,5,6 WT -232 METAL INDUSTRIES 598 F 16 2160 630 RIGHT NEW, REPLACE EXISTING WT, 1,3,5,6 WT -233 METAL INDUSTRIES 598 D 12 840 330 RIGHT NEW, REPLACE EXISTING WIT, 1,3,5,6 VVT -234 ' METAL INDUSTRIES 598 B 8 540 210 RIGHT NEW, REPLACE EXISTING WT, 1,3,5,6 VVT-235 METAL INDUSTRIES 598 D 12 890 330 RIGHT NEW, REPLACE EXISTING WIT, 1,3,5,6 VVT -236 UNKNOWN - - - VVT -137 DEMO WT -237 METAL INDUSTRIES 598 B 8 630 150 RIGHT NEW, REPLACE EXISTING WT, 1,3,5,6 WT -238 METAL INDUSTRIES 598 B 8 340 150 RIGHT NEW, REPLACE EXISTING WT, 1,3,5,6 VVT-239 METAL INDUSTRIES 598 D 12 1460 380 RIGHT NEW, REPLACE EXISTING VVT, 1,3,5,6,7 WT-240 METAL INDUSTRIES 598 B 8 300 150 RIGHT NEW, REPLACE EXISTING WIT, 1,3,5,6 VVT -241 METAL INDUSTRIES 598 B 10 560 150 RIGHT NEW, REPLACE EXISTING WT, 1,3,5,6 WT -242 UNKNOWN - - - DEMO WT -243 METAL INDUSTRIES 598 B 8 520 260 RIGHT NEW, REPLACE EXISTING WWT, 1,3,5,6 * LOCAT FLOOR 1 - SINGLE DUCT VVT BOX SCHEDULE UNIT NO. MFG & MODEL NO. INLET SIZE (IN) VALVE CFM CONTROLS ' NOTES 1 MAX MIN LOCATION* \ VVT -101 NAILOR 3001 12 470 230 RIGHT REBAL, EXISTING, 1,2,4 VVT -102 NAILOR 3001 12 860 340 RIGHT REBAL, EXISTING, 1,2,4 VVT -103 NAILOR 3001 12 1380 500 RIGHT REBAL, EXISTING, 1,2,4 VVT -104 NAILOR3001 12 860 330 LEFT EXISTING, 1,2,4 VVT -105 NAILOR 3001 12 520 160 RIGHT EXISTING, 1,2,4 VVT -106 NAILOR 3001 12 350 110 LEFT EXISTING, 1,2,4 VVT -107 NAILOR3001 8 460 140 RIGHT EXISTING, 1,2,4 VVT -108 NAILOR3001 12 640 190 LEFT EXISTING, 1,2,4 VVT -109 NAILOR3001 12 870 260 RIGHT EXISTING, 1,2,4 VVT -110 NAILOR 3001 14 1100 330 RIGHT EXISTING, 1,2,4 VVT -111 NAILOR 3001 8 340 100 LEFT EXISTING, 1,2,4 VVT -112 NAILOR 3001 8 220 70 LEFT EXISTING, 1,2,4 VVT -113 , NAILOR 3001 1 12 840 250 RIGHT EXISTING, 1,2,4 VVT -114 NAILOR3001 12 900 330 RIGHT EXISTING, 1,2,4 VVT -1 15 NAILOR 3001 12 530 160 LEFT EXISTING, 1,2,4 VVT -116 NAILOR3001 12 460 330 RIGHT EXISTING, 1,2,4 VVT -117 NAILOR3001 12 210 60 LEFT EXISTING, 1,2,4 J VVT - 118 NAILOR 3UU1 8 50 20 LEFT EXISTING, 1,2,4 VVT -119 NAILOR 3001 12 300 90 LEFT EXISTING, 1,2,4 VVT -120 NAILOR 3001 10 180 50 LEFT EXISTING, 1,2,4 VVT -121 NAILOR3001 ' 10 360 110 RIGHT EXISTING, 1,2,4 VVT-122 NAILOR3001 12 550 170 RIGHT EXISTING, 1,2,4 , VVT -123 METAL INDUSTRIES 598 C 10 1020 320 RIGHT NEW, REPLACE EXISTING VVT, 1,3,5,6 VVT -124 METAL INDUSTRIES 598 C 10 920 310 RIGHT NEW, REPLACE EXISTING VVT, 1,3,5,6 WT -125 METAL INDUSTRIES 598 C 10 760 320 RIGHT NEW, REPLACE EXISTING VVT, 1,3,5,6 WT -126 METAL INDUSTRIES 598 D 12 1300 330 RIGHT NEW, REPLACE EXISTING WT, 1,3,5,6 VVT -127 METAL INDUSTRIES 598 D 12 1290 330 RIGHT NEW, REPLACE EXISTING VVT, 1,3,5,6 VVT -128 METAL INDUSTRIES 598 B 8 490 150 RIGHT NEW, REPLACE EXISTING VVT, 1,3,5,6 VVT -129 METAL INDUSTRIES 598 B 8 380 150 RIGHT NEW, REPLACE EXISTING VVT, 1,3,5,6 VVT -130 METAL INDUSTRIES 598 C 10 1070 210 RIGHT NEW, REPLACE EXISTING WT, 1,3,5,6 VVT -131 METAL INDUSTRIES 598 D 12 1300 330 RIGHT NEW, REPLACE EXISTING WT, 1,3,5,6 WVT 132 METAL INDUSTRIES 598 B 8 260 150 RIGHT NEW, REPLACE EXISTING WT, 1,3,5,6 VVT -133 METAL INDUSTRIES 598 D 12 1240 330 RIGHT NEW, REPLACE EXISTING WT, 1,3,5,6 VVT -134 : METAL INDUSTRIES 598 D 12 1530 330 RIGHT NEW, REPLACE EXISTING VVT, 1,3,5,6 WT-135 METAL INDUSTRIES 598 A 6 I 180 70 RIGHT NEW, REPLACE EXISTING WT, 1,3,5,6 VVT -136 METAL INDUSTRIES 598 B 8 460 150 RIGHT NEW, REPLACE EXISTING WT, 1,3,5,6 VVT -137 METAL INDUSTRIES 598 B 8 410 180 RIGHT NEW, REPLACE EXISTING VVT, 1,3,5,6 WT -138 METAL INDUSTRIES 598 C 10 480 330 RIGHT NEW, REPLACE EXISTING VVT, 1,3,5,6 VVT -139 METAL INDUSTRIES 598 D 1 12 1220 330 RIGHT NEW, REPLACE EXISTING VVT, 1,3,5,6 DAMPER LEGEND SYMBOL DESCRIPTION- POWERED SYMBOL DESCRIPTION -NON POWERED FSD HFSD TFSD FSD HFSD SD MD SCD AD 1 1/2 HOUR VERTICAL COMBINATION FIREISMOKE FD HFD FD HFD FD BDD 1 1/2 HOUR CURTAIN STYLE VERTICAL FIRE DAMPER 1 Y2 GREENHECK FSD 212 (2000 FPM) OR EQUAL GREENHECK' FSD 312 (3000 FPM) OR EQUAL. 1 1/2 HOUR HORIZONTAL COMBINATION FIRE /SMOKE GREENHECK DFD 150 OR EQUAL 1 1/2 HOUR CURTAIN STYLE HORIZONTAL FIRE DAMPER GREENHECK DFD 150 (HORIZONTAL MOUNT) OR EQUAL 3 HOUR CURTAIN STYLE VERTICAL ARE DAMPER - GREENHECK FSD 212 (2000 FPM) OR EQUAL GREENHECK FSD 312 (3000 FPM) OR EQUAL 1 112 HOUR TUNNEL CORRIDOR COMBINATION FIREISMIOKE GREENHECK DFD 350 OR EQUAL 3 HOUR CURTAIN STYLE HORIZONTAL FIRE DAMPER GREENHECK CFSD 212 -1 OR EQUAL 3 HOUR VERTICAL COMBINATION RR'EISMOKE GREENHECK DFD 350 (HORIZONTAL MOUNT) OR EQUAL CEILING RADIATION DAMPER GREENHECK FSD 231 OR EQUAL 3 HOUR HORIZONTAL COMBINATION FIRE/SMOKE GREENHECK CRD-2 OR EQUAL BACKDRAFT DAMPER 3 GREENHECK FSD 231 OR EQUAL SMOKE DAMPER BAR .05 I A GREENHECK WD 330 (VERT) OR WD -100 (HORIZONTAL) OR EQUAL BAROMETRIC RELIEF DAMPER (.05 OPNG PRESSURE SHOWN) "\ RUSKIN CBD2 NO SUBSTITUTE ALLOWED VOLUME DAMPER SHOP FABRICATED, W/ LOCKING QUADRANT GREENHECK SMD 202 OR EQUAL MOTORIZED CONTROL DAMPER 3. ALL PIPE SIZES NOTED ON DRAWINGS ARE MINIMUMS. GREENHECK VCD -23 OR' EQUAL SMOKE CONTROL MOTORIZED DAMPER GREENHECK SMD 301 OR EQUAL 5. HANGERS AND SUPPORTS FOR PIPING SHALL BE IN ACCORDANCE WITH THE 2006 IMC AND IBC AS AMENDED BY THE STATE OF WASHINGTON AND LOCAL AUTHORITIES. INTERLOCK WITH FIRE ALARM BY ELECTRICAL. CONTRACTOR ACCESS DOOR. > 18" x 18" MINIMUM THROUGH BUILDING CONSTRUCTION BY GENERAL CONTRACTOR GENERAL NOTES: COMBINATION FIRE /SMOKE DAMPER REQUIREMENTS (UNLESS OTHERWISE NOTED): - CLASS II - 165° FUSIBLE LINK - FAIL - CLOSE, 120V ACTUATOR - ACTUATOR BY MECHANICAL CONTRACTOR, WIRING BY ELECTRICAL CONTRACTOR - INTERLOCK TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR FIRE DAMPER REQUIREMENTS: - BLADES OUT OF AIRSTREAM ON MEDIUM PRESSURE DUCTS - 165 F FUSIBLE LINK - CLASS II FITTING GENERAL NOTES PIPING MATERIAL SCHEDULE: PIPING SIZE MATERIAL JOINT NATURAL GAS 112 - 2" SCH 40 BLK STL ASTM A53 A OR B THREADED, FLANGED, SOCKET WELDED ELECTRICAL 2-1/2" 10 "' SCH 40 BLK STL BUTT WELDED NO. TYPE ASTM A53 A OR B FLANGED, 1. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE MECHANICAL CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. 2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2006 IBC, IMC, AND UPC AS AMENDED BY THE STATE OF WASHINGTON AND LOCAL AUTHORITIES. 3. ALL PIPE SIZES NOTED ON DRAWINGS ARE MINIMUMS. 4 . SLOPE ALL INDIRECT DRAINS AT 2% UNLESS OTHERWISE NOTED ON DRAWINGS. OBTAIN APPROVAL FROM CODE AUTHORITY BEFORE INSTALLING PIPING AT LESS THAN 2% (EVEN IF LESSER SLOPE IS INDICATED ON DRAWINGS). 5. HANGERS AND SUPPORTS FOR PIPING SHALL BE IN ACCORDANCE WITH THE 2006 IMC AND IBC AS AMENDED BY THE STATE OF WASHINGTON AND LOCAL AUTHORITIES. 6. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 7 PROVIDE SHUT -OFF VALVES AT ALL EQUIPMENT CONNECTIONS. 8 PROVIDE UNION, GROOVED OR FLANGED CONNECTION AT EQUIPMENT FOR FUTURE REMOVAL AND SERVICING. 9 FOR CONDENSATE PIPING PROVIDE TRAPS WITH A MINIMUM SEAL 2" GREATER THAN THE FAN OPERATING STATIC PRESSURE AT ALL COOLING COIL CONNECTIONS. 10 PROVIDE MINIMUM 1" AIR BREAK FOR ALL CONDENSATE PIPE TERMINATIONS AT DRAINS. 11 PROVIDE DIELECTRIC CONNECTIONS BETWEEN DISSIMILAR METALS. DUCT LEGEND DX CONDENSING UNIT SCHEDULE UNIT NO. MFG & MODEL NO. ARI COOL TONS EER/ IPLV COMPRESSOR NO. REF CIRCUITS SUC LINE (IN) LIQ LINE (IN) ELECTRICAL CONTROL WT LBS NOTES NO. TYPE HP EACH RPM VOLT /PH MCA CU -101 RHEEM RAKA- 037DAZ 3 14/12 W 14/ 12-e- M -M METAL EGGCRATE BARE ROUND SHEETMETAL RETURN/EXH FLAT OVAL FLAT SHEETMETAL W/ INSULATION (2") 460/3 120 �14 12 -&W 24/24 EXPOSED QUALITY SHEETMETAL 24V EXIST, 1 REBAL, EXISTING, 2 CU -102 RHEEM RAKA- 037DAZ 3 EXAMPLE OF NEW � EXAMPLE OF NOT IN CONTRACT (NIC) - 14/12 RTU -103 EXAMPLE OF DEMO XX FLEX DUCT x x x x x x x EXIST, 1 CU -103 CU -104 RHEEM RAKA- 037DAZ RHEEM RAKA- 037DAZ 3 3 �. EXISTING 225 ■ 10 80 �- ■ - - EXIST, 1 1 REBAL, EXISTING, 2 FCU -104 LAB 1 RHEEM RAKA- 037DAZ EXIST, 1 0 - - - 24V REBAL, EXISTING, 2 CU -201 EXIST, ABANDONED FCU-201 DUCT LEGEND DESCRIPTION SYMBOL DESCRIPTION SYMBOL BARE SHEETMETAL 0 SIZE ROUND SHEETMETAL WRAPPED W/ INSULATION (2 ") AS NOTED 14/12 120W CFM SOUNDLINE SHEETMETAL (1 " LINING) POWER EXH MOTOR 11,700 CFM 4©a1 HP EACH CLEANROOM QUALITY DUCTWORK RETU'RNIEXH 1 14/12 SL 14/12 C SIZE SHEETMETAL WRAPPED W/ INSULATION (2 ") AS NOTED BARE FLAT OVAL SHEETMETAL NEW 14/12 W 14/ 12-e- M -M METAL EGGCRATE BARE ROUND SHEETMETAL RETURN/EXH FLAT OVAL FLAT SHEETMETAL W/ INSULATION (2") 460/3 120 �14 12 -&W 24/24 EXPOSED QUALITY SHEETMETAL 24V DUCTBOARD (1" FIBERGLASS) REBAL, EXISTING, 2 14/12 0 14/12 DB RHEEM RAKA- 037DAZ EXAMPLE OF NEW � EXAMPLE OF NOT IN CONTRACT (NIC) - 14/12 RTU -103 EXAMPLE OF DEMO XX FLEX DUCT x x x x x x x EXAMPLE OF EXISTING FCU -103' FLEX CONNECTOR 460/3 14/1 2 EXISTING 225 180 DIFFUSER/GRILLE SCHEDULE SYMBOL MANUFACTURER & MODEL NUMBER SIZE TYPE NOTES 0 SIZE NOTES EXISTING, 1 -5 AS NOTED T -BAR LAY -IN MODULAR CORE DIFFUSER EXISTING, 1 CFM , SIZE POWER EXH MOTOR 11,700 CFM 4©a1 HP EACH AS NOTED RETU'RNIEXH 1 EXISTING ''U'' CFM SIZE SHOEMAKER 701 -MA AS NOTED T -BAR LAY -IN MODULAR CORE DIFFUSER NEW CFM imi M -M METAL EGGCRATE 12124 RETURN/EXH 8,521 460/3 \ M -M METAL EGGCRATE 24/24 RETURN/EXH 24V 1'9fTFC• PACKAGED GAS/ELEC AIR CONDITIONING ROOFTOP UNIT SCHEDULE UNIT NO. MFG & MODEL NO. AREA SERVED FANS WEIGHT (LBS) 6,658 ELECTRICAL NOTES EXISTING, 1 -5 SUPPLY CFM 20,000 MIN OA (CFM) 3,680 SUPPLY MOTOR (HP) 1 @30 HP ESP (IN) 1.2 RPM 1242 POWER EXH MOTOR 11,700 CFM 4©a1 HP EACH VOLT/ PH 460/3 MCA 150 RTU -101 CARRIER 48AKTO5ODSQ611HM EAST WING RTU -102 CARRIER 48A3T060DSV611HM WEST WING 24,000 7,200 1 @30 HP 1.2 1010 17,550 CFM 8,521 460/3 174 NEW, REPLACE - R-410A 24V 954 REBAL, EXISTING, 2 FCU -102 LAB 2 NORTH RHEEM RAKA- 037DAZ 6 @1 HP EACH � 2 1/4 EXIST, 1,2,3,6 RTU -103 CARRIER 48TJD014 SERIES# 601 QE SERIAL# 4 1 94 630497 2ND FLOOR SOUTH 5,000 1 ©4.2 BHP 1.2 1140 FCU -103' 1287 460/3 36 EXISTING UNIT NO. DX A/C - FAN COIL UNIT SCHEDULE UNIT NO. AREA SERVED MFG & MODEL NO. BLOWER OSA 'CFM ELECTRICAL HEAT CONTROL WT LBS NOTES CFM ESP HP RPM VOLT /PH MCA VOLT /PH KW STG FCU -101 LAB 3 RHEEM RAKA- 037DAZ 1200 82 RTU -102 CARRIER 48A3T060DSV611 HM 0 682 544 - - R-410A 24V 954 REBAL, EXISTING, 2 FCU -102 LAB 2 NORTH RHEEM RAKA- 037DAZ 1200 � 2 1/4 0 - NEW, 1,2,3,5 - - 24V CARRIER 48TJD014 SERIES# 601 QE SERIAL# 4194G30497 REBAL, EXISTING, 2 FCU -103' LAB 2 SOUTH RHEEM RAKA- 037DAZ 1200 R -22 225 180 10 80 - - - 24V 1 REBAL, EXISTING, 2 FCU -104 LAB 1 RHEEM RAKA- 037DAZ 1200 0 - - - 24V REBAL, EXISTING, 2 FCU-201 EXISTING, ABANDONED,1 UNIT NO. MFG & MODEL NO. COOLING HEATING COOLING TOTAL (TONS) COOLING TOTAL (MBH) COOLING SENS (MBH) EER/ SEER IPLV REFER TYPE HEAT INPUT (MBH) HEAT OUTPUT (MBH) STAGES ( #) AFUE ( %) RTU -101 CARRIER 48AKTO5ODSQ611 HM 50 600 456 9.31 9.5 R -22 800 1 656 5 82 RTU -102 CARRIER 48A3T060DSV611 HM 60 682 544 10.101 9.5 R-410A 1164 954 9 ' 82 5.0 21 760 277/1 2 1/4 277/1 - NEW, 1,2,3,5 RTU -103 1,1 /lTl - i,. CARRIER 48TJD014 SERIES# 601 QE SERIAL# 4194G30497 12.5 158 118 8.6/ 8.85 R -22 225 180 2 80 CO 0 0 1. ELECTRICAL DISCONNECT SWITCH AND POWER WIRING BY ELECTRICAL CONTRACTOR. 2. VFD MOTORS 3. FEATURES AND OPTIONS INCLUDED: - COMFORTLINK CONTROLS WITH VISUAL SCROLLING MARQUEE DISPLAY - HIGH GAS HEAT WITH STAINLESS STEEL HEAT EXCHANGER/BURNER - ALICU COND AND EVAP - DIFFERENTIAL DRY -BULB ECONOMIZER - FACTORY INSTALLED POWER EXHAUST - HOT GAS BYPASS - BACNET TRANSLATOR CONTROLS INTERFACE - RETURN AIR SMOKE DETECTOR - 115V FACTORY WIRED CONVENIENCE OUTLET - CO2 SENSOR 4. MAXIMUM SOUND POWER LEVEL OF 99 DECIBELS RATED IN ACCORDANCE WITH ARI STANDARD 270 5. NEW UNIT WEIGHT (6,658 LBS) IS LESS THAN UNIT REPLACED (6,800 LBS). NO STRUCTURAL REVIEW REQUIRED PER CITY OF TUKWILA. 6. MAXIMUM SOUND POWER LEVEL OF 100 DECIBELS RATED IN ACCORDANCE WITH ARI STANDARD 270 LOCATION OF CONTROLS ON VVT BOX BASED ON LOOKING IN DIRECTION OF AIRFLOW (AIR HITTING BACK OF HEAD) NOTES: 1. FACTORY TOGGLE INTERLOCKING DISCONNECT 2. W/ LOW VELOCITY MULTIPOINT AVERAGING FLOW SENSOR 3. WI FACTORY STANDARD MULTIPOINT AVERAGING FLOW SENSOR 4. CONFIGURED FOR FIELD MOUNTED STAEFA DDC CONTROLS PROVIDED BY MECHANICAL CONTRACTOR 5. ORDERED W/ FACTORY STANDARD RIGHT -HAND CONFIGURATION. HELD TO FLIP BOX IN FIELD AS NECESSARY TO MAINTAIN CONTROL BOX CLEARANCES. 6. W/ FACTORY MOUNTED DDC CONTROLS PROVIDED BY FACTORY. ION OF CONTROLS ON VVT BOX BASED ON LOOKING IN DIRECTION OF AIRFLOW (AIR HITTING BACK OF HEAD). NOTES: 1. FACTORY TOGGLE INTERLOCKING DISCONNECT 2. W/ LOW VELOCITY MULTIPOINT AVERAGING FLOW SENSOR 3. WI FACTORY STANDARD MULTIPOINT AVERAGING FLOW SENSOR 4. CONFIGURED FOR FIELD MOUNTED STAEFA DDC CONTROLS PROVIDED BY MECHANICAL CONTRACTOR 5. ORDERED W/ FACTORY STANDARD RIGHT -HAND CONFIGURATION. FIELD TO FLIP BOX IN FIELD AS NECESSARY TO MAINTAIN CONTROL BOX CLEARANCES. 6. WI FACTORY MOUNTED DDC CONTROLS PROVIDED BY FACTORY. 7. VENTILATION CONTROL BY ROOM CO2 SENSOR PROVIDED AND INSTALLED BY M -M. • 1. DIFFUSERS TYPICALLY LABELED WITH EXTERIOR DIMENSIONS, 24x24 FOR SQUARE DIFFUSERS AND 6x48 FOR SLOT DIFFUSERS. NOTES: 1. NO INFORMATION ON THIS UNIT, ABANDONED IN PLACE. 2. UNIT FOR SPACE COOLING ONLY, ZERO MIN OSA, VENTILATION AIR PROVIDED BY EXISTING BUILDING HVAC SYSTEM. NOTES: 1. FIELD LOCATE UNIT, COMPLETE INFORMATION IN SCHEDULE FROM EQUIPMENT TAG AND MARK UNIT LOCATION ON THE AS -BUILT DRAWING. NOTES: 1. POWER WIRING AND DISCONNECT SWITCH BY ELECTRICAL CONTRACTOR 2. WI MULTIPOINT AVERAGING FLOW SENSOR 3. CONFIGURED FOR FIELD MOUNTED STAEFA DDC CONTROLS PROVIDED BY MECHANICAL CONTRACTOR 4. LEFT HAND SIDE CONTROLS ENCLOSURE LOCATION BASED ON LOOKING IN DIRECTION OF AIRFLOW (AIR HITTING BACK OF HEAD). 5. RIGHT HAND SIDE CONTROLS ENCLOSURE LOCATION BASED ON LOOKING IN DIRECTION OF AIRFLOW (AIR HITTING BACK OF HEAD). 6. ELECTRIC HEAT INSTALLED WITH 3 -WIRES AT 277V/1 PH WHICH RESULTS IN REDUCED HEATING CAPACITY. HVAC GENERAL NOTES 1. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. 2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2006 EDITIONS OF THE INTERNATIONAL' MECHANICAL CODE, INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE AND STATE AND LOCAL CODES AND ORDINANCES. 3. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 6 OF THE 2006 IMC AND WITH CURRENT SMACNA STANDARDS. 4. JOINTS OF MEDIUM AND HIGH VELOCITY DUCT SYSTEMS SHALL BE SEALED WITH GASKETS OR LISTED MASTIC TYPE DUCT SEALANT. 5. DUCTS SHALL BE INSULATED AS INDICATED ON PLANS, PER 2006 WSEC. - DUCT WRAP, WHERE INDICATED, SHALL BE 1 1/2" 0.75 LB/CU FT FIBERGLASS DUCT INSULATION WITH A FACTORY APPLIED REINFORCED ALUM. FOIL VAPOR BARRIER (R -4.2 MIN.). - SOUND LINING, WHERE INDICATED, SHALL BE 1" 1.5 LB /CU FT FIBERGLASS DUCT LINING COATED TO PREVENT FIBER EROSION AT VELOCITIES UP TO 6000 FPM (R-4.2 MIN.). - DUCT BOARD, WHERE INDICATED, SHALL BE 1" RIGID FRK FACED El 475 FIBERGLASS DUCT BOARD SYSTEM, UL 181 LISTED AS A CLASS 1 AIR DUCT (R-4.3 MIN.). 6. FLEX DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER, 1 112" FIBERGLASS INSULATION, AND NON - PERFORATED INTERIOR LINER WITH WIRE HELIX. DUCT SHALL BE A UL 181 LISTED CLASS 1 AIR DUCT. FLEX DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 8' IN LENGTH UNLESS NOTED OTHERWISE. 7. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 1613 OF THE 2006 IBC. 1 8. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY' AND RATING OF THE FLOOR OR WALL. 9. PROVIDE RETURN DUCT SMOKE DETECTOR AUTOMATIC SHUT DOWN OF ALL NEW HEATING, COOLING, OR VENTILATION EQUIPMENT MOVING IN EXCESS OF 2000 CFM IN ACCORDANCE WITH SECTION 606 OF THE 2006 IMC. POWER AND INTERLOCK WIRING WITH THE BUILDING FIRE ALARM SYSTEM IS BY THE ELECTRICAL CONTRACTOR. 10.HVAC EQUIPMENT, VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. 11. MOTOR STARTERS NOT LISTED AS BEING PROVIDED IN THE HVAC EQUIPMENT SCHEDULES ARE TO BE PROVIDED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. 12. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER. RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM, INCLUDING SIZES, AND THE TERMINAL AIR AND WATER DESIGN FLOW RATES. 13. OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE: SUBMITTAL DATA, NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY, HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM. 14.COMMISSIONING IS REQUIRED ON THIS. PROJECT IN ACCORD WITH WASHINGTON STATE ENERGY CODE (WSEC) SECTION 1416 AND WITH LEED NC -2.1 FUNDAMENTAL BUILDING SYSTEMS COMMISSIONING AND ADDITIONAL COMMISSIONING. 15.A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER. 16. DAMPERS USED FOR OUTDOOR AIR INTAKE, EXHAUST, OR RELIEF SHALL HAVE THE FOLLOWING MAXIMUM LEAKAGE RATES AT 1" W.G. (PER AMCA STANDARD 500): MOTORIZED DAMPERS: 10 CFM/S.F. GRAVITY DAMPERS: 20 CFM/S.F. (40 CFM IS.F. FOR DAMPERS SMALLER THAN 24 INCHES IN EITHER DIMENSION). 17.OUTSIDE AIR INTAKE, EXHAUST, AND RELIEF DAMPERS SERVING CONDITIONED SPACES MUST BE' MOTORIZED (FAIL CLOSED) PER WSEC 1412.4.1, EXCEPT AS ALLOWED BY WSEC. HVAC ABBREVIATIONS ABBV FULL NAME ABBV FULL NAME ABBV FULL NAME A AC AFF AL BDD BOB BOD BOTT BTU BTUH BWG BWR C CAP CC CFM CHWR CHWS COMB CONN CWR CWS DB DIFF DMPR DN EC EGC EER ELEV EMS COMPRESSED AIR LINE AIR CONDITIONING UNIT ABOVE FINISHED FLOOR ALUMINUM BACKDRAFT DAMPER BOTTOM OF BEAM BOTTOM OF DUCT BOTTOM BRITISH THERMAL UNITS BRITISH THERMAL UNITS PER HOUR BOTTOM WALL GRILLE BOTTOM WALL REGISTER CONDENSATE CAPACITY CONTROLS CONTRACTOR CUBIC FEET PER MINUTE CHILLED WATER RETURN CHILLED WATER SUPPLY COMBUSTION CONNECT CONDENSER WATER RETURN CONDENSER WATER SUPPLY DUCT BOARD DIFFUSER DAMPER DOWN ELECTRICAL CONTRACTOR EGGCRATE ENERGY EFFICIENCY' RATIO ELEVATION ENERGY MANAGEMENT SYSTEM ESP EXH EXTR FAC FD FLA FOB FOT FSD G GALV GC GPM GR GWB HG HP HWR HWS ID INT LIQ M -M MBH MC MCA MD MIN MT MUA NOM EXTERNAL STATIC PRESSURE EXHAUST EXTRACTOR FIRE ALARM CONTRACTOR FIRE DAMPER FULL LOAD AMPS FLAT ON BOTTOM FLAT ON TOP FIRE SMOKE DAMPER GAS LINE GALVANIZED GENERAL CONTRACTOR GALLONS PER MINUTE. GRILLE GYPSUM WALL BOARD HOT GAS LINE HORSE POWER HOT WATER' RETURN HOT WATER SUPPLY INSIDE DIMENSION INTERLOCK. LIQUID LINE MACDONALD - MILLER ONE THOUSAND BTUH MECHANICAL CONTRACTOR MINIMUM CIRCUITA'MPACITY MOTORIZED DAMPER MINIMUM MOUNT MAKE -UP AIR NOMINAL OSA OBD OD RA REG REQ'D RIO SA SCD SD SL SM SP SS SSSC STL SUC SUSP T'STAT TC TOD TOS TV TWG TWR TYP UNO VD VFD OUTSIDE AIR. OPPOSED BLADE DAMPER OUTSIDE DIMENSION RETURN AIR REGISTER (GRILLE WITH DAMPER) REQUIRED ROUGH IN ONLY SUPPLY AIR SMOKE CONTROL DAMPER. SMOKE DAMPER SOUND LINING SHEET METAL STATIC PRESSURE START /STOP SOLID STATE SPEED CONTROLLER STEEL SUCTION LINE SUSPENDED THERMOSTAT TEMPERATURE CONTROL TOP OF DUCT TOP OF STEEL TURN VANES TOP WALL GRILLE TOP WALL REGISTER TYPICAL UNLESS NOTED OTHERWISE VOLUME DAMPER VARIABLE FREQUENCY DRIVE VOLTAGE PHASE & DUCT DIAMETER NAME TITLE TM0.01 SCHEDULES - HVAC TM0.01S SITE MAP DM2.01 1ST FLOOR DEMO PLAN - HVAC TM2.01 1ST FLOOR PLAN - HVAC DM2.02 2ND FLOOR' DEMO PLAN - HVAC TM2.02 2ND FLOOR PLAN - HVAC TM2.03 ROOF PLAN AND ELEVATION - HVAC TITLE PROJECT MANAGER PROJECT ENGINEER SHEETMETAL FOREMAN AIR BALANCE FOREMAN ELECTRICAL FOREMAN CONTROLS FOREMAN REFRIGERATION FOREMAN NAME STEVE FLINK. CHRIS LEE LARRY HARBISON BRAD SHARP MIKE MCGIVERN SABRINA WORKMAN STEVE HARBISON OPERATIONS MANAGER GREG COLEMAN DRAWING SHEET INDEX CONTACT LIST COMPANY NAME MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER RREEF NO SCALE TITLE SCOPE OF WORK REPLACE (1) EXISTING PACKAGED ROOFTOP UNIT, INCLUDES NEW M -M CUSTOM FABRICATED CURB RECONNECT EXISTING NATURAL GAS LINE TO NEW ROOFTOP UNIT. ELECTRICAL DISCONNECT /CONNECT FOR NEW ROOFTOP UNIT. REPLACE (37) EXISTING VVT BOXES. DEMO (2) VVT BOXES. INSTALL (1) PARALLEL VAV BOX WITH ELECTRIC HEAT. MODIFICATION OF EXISTING LOW PRESSURE DUCT AS SHOWN ON THE DRAWINGS. NEW STAEFA CONTROLS SYSTEM FOR NEW VAV BOXES. INSTALL (1) CO2 SENSOR. AIR BALANCE (1) RTU, (41) WT BOXES, (1) PARALLEL VAV BOX, AND (4) FANCOIL UNITS. 48TH AVE S VICINITY MAP PHONE NUMBER 253 - 681 -3172 206 - 768 -4266 206 - 423 -4294 206 -768 -4112 206 - 768 -4046 206-768-4074 206 - 768 -4032 206 - 788 -4404 ADAPTER. INTERURBAN AVE S DUWAMISH RIVER FOR CODE CO P KE APPR f FAX NUMBER 206 - 768 - 253 -681 -3173 206- 768 -4267 206 - 768 -4295 206 - 768 -4047 206 - 768 -4075 206 - 768 -4033 SEPARATE PERMI REQUIRED FOR: 0 Mechanical FlA tric ati Plumbing Clas Pi oina City of Tukwila BUILDING DIVISION REVISIONS N o changes shall be made to the scope of work without prior approval of Tukwila. Building Division. NOTE: Revisions will require a new plan submittal I and may include additional plan review tees. LEGAL DESCRIPTION APN # 2716000070 LEGAL DESCRIPTION: GATEWAY CORPORATE CENTER PARCEL B OF CITY OF TUKWILA SHORT PLAT NO 89 -1 -SS RECORDING NO 8904120877 SD SHORT PLAT DAF - LOT 7 OF GATEWAY CORPORATE CENTER Mar review approval is subject to errors and omlssions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Reid Copy and co ons is acknowledged: By r Date: CX.,1 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY 2 8 2008 PERMIT CENTER MacDonald-Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206- 763 -9400 Fax: 206- 767 - 6773 www.macmiller.com WA Lic No: MACDOFS980RU EXPIRES: 07 -06 -08 GATEWAY BLDG 7 PHASE 2 12720 GATEWAY DR S TUKWILA WA 98168 SCHEDULES - HVAC ENGINEER: C LEE CHECKED BY: E GEZON D IKERD LAST REVISED: 05 -21 -08 DATE PLOTTED: 05 -21 -08 ISSUE DATE. 05 -22 -08 DRAWING NUMBER: E- 0182- 73862.15 -00 ISSUED FOR CONSTRUCTION SHEET NUMBER: y ,. V [ gte() CD- PERMIT SET 05 -22 -08 REVISIONS: DATE C^. 0 0 I 0 C3 0 CO a Co N z PARALLEL VAV BOX SCHEDULE UNIT NO. MFG & MODEL NO. INLET SIZE VALVE CFM HEATER FAN NOTES MAX MIN KW DT CFM VOLT /PH STGS HP VOLT /PH SPD VAV -201 NAILOR 35NE SIZE 2 8 260 80 3.0 30 310 480/3 1 1/10 277/1 - EXISTING, 1,2,3,4,6 VAV -202 NAILOR 35NE SIZE 3 10 910 210 5.0 21 760 277/1 2 1/4 277/1 - NEW, 1,2,3,5 CO 0 0 1. ELECTRICAL DISCONNECT SWITCH AND POWER WIRING BY ELECTRICAL CONTRACTOR. 2. VFD MOTORS 3. FEATURES AND OPTIONS INCLUDED: - COMFORTLINK CONTROLS WITH VISUAL SCROLLING MARQUEE DISPLAY - HIGH GAS HEAT WITH STAINLESS STEEL HEAT EXCHANGER/BURNER - ALICU COND AND EVAP - DIFFERENTIAL DRY -BULB ECONOMIZER - FACTORY INSTALLED POWER EXHAUST - HOT GAS BYPASS - BACNET TRANSLATOR CONTROLS INTERFACE - RETURN AIR SMOKE DETECTOR - 115V FACTORY WIRED CONVENIENCE OUTLET - CO2 SENSOR 4. MAXIMUM SOUND POWER LEVEL OF 99 DECIBELS RATED IN ACCORDANCE WITH ARI STANDARD 270 5. NEW UNIT WEIGHT (6,658 LBS) IS LESS THAN UNIT REPLACED (6,800 LBS). NO STRUCTURAL REVIEW REQUIRED PER CITY OF TUKWILA. 6. MAXIMUM SOUND POWER LEVEL OF 100 DECIBELS RATED IN ACCORDANCE WITH ARI STANDARD 270 LOCATION OF CONTROLS ON VVT BOX BASED ON LOOKING IN DIRECTION OF AIRFLOW (AIR HITTING BACK OF HEAD) NOTES: 1. FACTORY TOGGLE INTERLOCKING DISCONNECT 2. W/ LOW VELOCITY MULTIPOINT AVERAGING FLOW SENSOR 3. WI FACTORY STANDARD MULTIPOINT AVERAGING FLOW SENSOR 4. CONFIGURED FOR FIELD MOUNTED STAEFA DDC CONTROLS PROVIDED BY MECHANICAL CONTRACTOR 5. ORDERED W/ FACTORY STANDARD RIGHT -HAND CONFIGURATION. HELD TO FLIP BOX IN FIELD AS NECESSARY TO MAINTAIN CONTROL BOX CLEARANCES. 6. W/ FACTORY MOUNTED DDC CONTROLS PROVIDED BY FACTORY. ION OF CONTROLS ON VVT BOX BASED ON LOOKING IN DIRECTION OF AIRFLOW (AIR HITTING BACK OF HEAD). NOTES: 1. FACTORY TOGGLE INTERLOCKING DISCONNECT 2. W/ LOW VELOCITY MULTIPOINT AVERAGING FLOW SENSOR 3. WI FACTORY STANDARD MULTIPOINT AVERAGING FLOW SENSOR 4. CONFIGURED FOR FIELD MOUNTED STAEFA DDC CONTROLS PROVIDED BY MECHANICAL CONTRACTOR 5. ORDERED W/ FACTORY STANDARD RIGHT -HAND CONFIGURATION. FIELD TO FLIP BOX IN FIELD AS NECESSARY TO MAINTAIN CONTROL BOX CLEARANCES. 6. WI FACTORY MOUNTED DDC CONTROLS PROVIDED BY FACTORY. 7. VENTILATION CONTROL BY ROOM CO2 SENSOR PROVIDED AND INSTALLED BY M -M. • 1. DIFFUSERS TYPICALLY LABELED WITH EXTERIOR DIMENSIONS, 24x24 FOR SQUARE DIFFUSERS AND 6x48 FOR SLOT DIFFUSERS. NOTES: 1. NO INFORMATION ON THIS UNIT, ABANDONED IN PLACE. 2. UNIT FOR SPACE COOLING ONLY, ZERO MIN OSA, VENTILATION AIR PROVIDED BY EXISTING BUILDING HVAC SYSTEM. NOTES: 1. FIELD LOCATE UNIT, COMPLETE INFORMATION IN SCHEDULE FROM EQUIPMENT TAG AND MARK UNIT LOCATION ON THE AS -BUILT DRAWING. NOTES: 1. POWER WIRING AND DISCONNECT SWITCH BY ELECTRICAL CONTRACTOR 2. WI MULTIPOINT AVERAGING FLOW SENSOR 3. CONFIGURED FOR FIELD MOUNTED STAEFA DDC CONTROLS PROVIDED BY MECHANICAL CONTRACTOR 4. LEFT HAND SIDE CONTROLS ENCLOSURE LOCATION BASED ON LOOKING IN DIRECTION OF AIRFLOW (AIR HITTING BACK OF HEAD). 5. RIGHT HAND SIDE CONTROLS ENCLOSURE LOCATION BASED ON LOOKING IN DIRECTION OF AIRFLOW (AIR HITTING BACK OF HEAD). 6. ELECTRIC HEAT INSTALLED WITH 3 -WIRES AT 277V/1 PH WHICH RESULTS IN REDUCED HEATING CAPACITY. HVAC GENERAL NOTES 1. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. 2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2006 EDITIONS OF THE INTERNATIONAL' MECHANICAL CODE, INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE AND STATE AND LOCAL CODES AND ORDINANCES. 3. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 6 OF THE 2006 IMC AND WITH CURRENT SMACNA STANDARDS. 4. JOINTS OF MEDIUM AND HIGH VELOCITY DUCT SYSTEMS SHALL BE SEALED WITH GASKETS OR LISTED MASTIC TYPE DUCT SEALANT. 5. DUCTS SHALL BE INSULATED AS INDICATED ON PLANS, PER 2006 WSEC. - DUCT WRAP, WHERE INDICATED, SHALL BE 1 1/2" 0.75 LB/CU FT FIBERGLASS DUCT INSULATION WITH A FACTORY APPLIED REINFORCED ALUM. FOIL VAPOR BARRIER (R -4.2 MIN.). - SOUND LINING, WHERE INDICATED, SHALL BE 1" 1.5 LB /CU FT FIBERGLASS DUCT LINING COATED TO PREVENT FIBER EROSION AT VELOCITIES UP TO 6000 FPM (R-4.2 MIN.). - DUCT BOARD, WHERE INDICATED, SHALL BE 1" RIGID FRK FACED El 475 FIBERGLASS DUCT BOARD SYSTEM, UL 181 LISTED AS A CLASS 1 AIR DUCT (R-4.3 MIN.). 6. FLEX DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER, 1 112" FIBERGLASS INSULATION, AND NON - PERFORATED INTERIOR LINER WITH WIRE HELIX. DUCT SHALL BE A UL 181 LISTED CLASS 1 AIR DUCT. FLEX DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 8' IN LENGTH UNLESS NOTED OTHERWISE. 7. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 1613 OF THE 2006 IBC. 1 8. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY' AND RATING OF THE FLOOR OR WALL. 9. PROVIDE RETURN DUCT SMOKE DETECTOR AUTOMATIC SHUT DOWN OF ALL NEW HEATING, COOLING, OR VENTILATION EQUIPMENT MOVING IN EXCESS OF 2000 CFM IN ACCORDANCE WITH SECTION 606 OF THE 2006 IMC. POWER AND INTERLOCK WIRING WITH THE BUILDING FIRE ALARM SYSTEM IS BY THE ELECTRICAL CONTRACTOR. 10.HVAC EQUIPMENT, VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. 11. MOTOR STARTERS NOT LISTED AS BEING PROVIDED IN THE HVAC EQUIPMENT SCHEDULES ARE TO BE PROVIDED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. 12. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER. RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM, INCLUDING SIZES, AND THE TERMINAL AIR AND WATER DESIGN FLOW RATES. 13. OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE: SUBMITTAL DATA, NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY, HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM. 14.COMMISSIONING IS REQUIRED ON THIS. PROJECT IN ACCORD WITH WASHINGTON STATE ENERGY CODE (WSEC) SECTION 1416 AND WITH LEED NC -2.1 FUNDAMENTAL BUILDING SYSTEMS COMMISSIONING AND ADDITIONAL COMMISSIONING. 15.A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER. 16. DAMPERS USED FOR OUTDOOR AIR INTAKE, EXHAUST, OR RELIEF SHALL HAVE THE FOLLOWING MAXIMUM LEAKAGE RATES AT 1" W.G. (PER AMCA STANDARD 500): MOTORIZED DAMPERS: 10 CFM/S.F. GRAVITY DAMPERS: 20 CFM/S.F. (40 CFM IS.F. FOR DAMPERS SMALLER THAN 24 INCHES IN EITHER DIMENSION). 17.OUTSIDE AIR INTAKE, EXHAUST, AND RELIEF DAMPERS SERVING CONDITIONED SPACES MUST BE' MOTORIZED (FAIL CLOSED) PER WSEC 1412.4.1, EXCEPT AS ALLOWED BY WSEC. HVAC ABBREVIATIONS ABBV FULL NAME ABBV FULL NAME ABBV FULL NAME A AC AFF AL BDD BOB BOD BOTT BTU BTUH BWG BWR C CAP CC CFM CHWR CHWS COMB CONN CWR CWS DB DIFF DMPR DN EC EGC EER ELEV EMS COMPRESSED AIR LINE AIR CONDITIONING UNIT ABOVE FINISHED FLOOR ALUMINUM BACKDRAFT DAMPER BOTTOM OF BEAM BOTTOM OF DUCT BOTTOM BRITISH THERMAL UNITS BRITISH THERMAL UNITS PER HOUR BOTTOM WALL GRILLE BOTTOM WALL REGISTER CONDENSATE CAPACITY CONTROLS CONTRACTOR CUBIC FEET PER MINUTE CHILLED WATER RETURN CHILLED WATER SUPPLY COMBUSTION CONNECT CONDENSER WATER RETURN CONDENSER WATER SUPPLY DUCT BOARD DIFFUSER DAMPER DOWN ELECTRICAL CONTRACTOR EGGCRATE ENERGY EFFICIENCY' RATIO ELEVATION ENERGY MANAGEMENT SYSTEM ESP EXH EXTR FAC FD FLA FOB FOT FSD G GALV GC GPM GR GWB HG HP HWR HWS ID INT LIQ M -M MBH MC MCA MD MIN MT MUA NOM EXTERNAL STATIC PRESSURE EXHAUST EXTRACTOR FIRE ALARM CONTRACTOR FIRE DAMPER FULL LOAD AMPS FLAT ON BOTTOM FLAT ON TOP FIRE SMOKE DAMPER GAS LINE GALVANIZED GENERAL CONTRACTOR GALLONS PER MINUTE. GRILLE GYPSUM WALL BOARD HOT GAS LINE HORSE POWER HOT WATER' RETURN HOT WATER SUPPLY INSIDE DIMENSION INTERLOCK. LIQUID LINE MACDONALD - MILLER ONE THOUSAND BTUH MECHANICAL CONTRACTOR MINIMUM CIRCUITA'MPACITY MOTORIZED DAMPER MINIMUM MOUNT MAKE -UP AIR NOMINAL OSA OBD OD RA REG REQ'D RIO SA SCD SD SL SM SP SS SSSC STL SUC SUSP T'STAT TC TOD TOS TV TWG TWR TYP UNO VD VFD OUTSIDE AIR. OPPOSED BLADE DAMPER OUTSIDE DIMENSION RETURN AIR REGISTER (GRILLE WITH DAMPER) REQUIRED ROUGH IN ONLY SUPPLY AIR SMOKE CONTROL DAMPER. SMOKE DAMPER SOUND LINING SHEET METAL STATIC PRESSURE START /STOP SOLID STATE SPEED CONTROLLER STEEL SUCTION LINE SUSPENDED THERMOSTAT TEMPERATURE CONTROL TOP OF DUCT TOP OF STEEL TURN VANES TOP WALL GRILLE TOP WALL REGISTER TYPICAL UNLESS NOTED OTHERWISE VOLUME DAMPER VARIABLE FREQUENCY DRIVE VOLTAGE PHASE & DUCT DIAMETER NAME TITLE TM0.01 SCHEDULES - HVAC TM0.01S SITE MAP DM2.01 1ST FLOOR DEMO PLAN - HVAC TM2.01 1ST FLOOR PLAN - HVAC DM2.02 2ND FLOOR' DEMO PLAN - HVAC TM2.02 2ND FLOOR PLAN - HVAC TM2.03 ROOF PLAN AND ELEVATION - HVAC TITLE PROJECT MANAGER PROJECT ENGINEER SHEETMETAL FOREMAN AIR BALANCE FOREMAN ELECTRICAL FOREMAN CONTROLS FOREMAN REFRIGERATION FOREMAN NAME STEVE FLINK. CHRIS LEE LARRY HARBISON BRAD SHARP MIKE MCGIVERN SABRINA WORKMAN STEVE HARBISON OPERATIONS MANAGER GREG COLEMAN DRAWING SHEET INDEX CONTACT LIST COMPANY NAME MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER RREEF NO SCALE TITLE SCOPE OF WORK REPLACE (1) EXISTING PACKAGED ROOFTOP UNIT, INCLUDES NEW M -M CUSTOM FABRICATED CURB RECONNECT EXISTING NATURAL GAS LINE TO NEW ROOFTOP UNIT. ELECTRICAL DISCONNECT /CONNECT FOR NEW ROOFTOP UNIT. REPLACE (37) EXISTING VVT BOXES. DEMO (2) VVT BOXES. INSTALL (1) PARALLEL VAV BOX WITH ELECTRIC HEAT. MODIFICATION OF EXISTING LOW PRESSURE DUCT AS SHOWN ON THE DRAWINGS. NEW STAEFA CONTROLS SYSTEM FOR NEW VAV BOXES. INSTALL (1) CO2 SENSOR. AIR BALANCE (1) RTU, (41) WT BOXES, (1) PARALLEL VAV BOX, AND (4) FANCOIL UNITS. 48TH AVE S VICINITY MAP PHONE NUMBER 253 - 681 -3172 206 - 768 -4266 206 - 423 -4294 206 -768 -4112 206 - 768 -4046 206-768-4074 206 - 768 -4032 206 - 788 -4404 ADAPTER. INTERURBAN AVE S DUWAMISH RIVER FOR CODE CO P KE APPR f FAX NUMBER 206 - 768 - 253 -681 -3173 206- 768 -4267 206 - 768 -4295 206 - 768 -4047 206 - 768 -4075 206 - 768 -4033 SEPARATE PERMI REQUIRED FOR: 0 Mechanical FlA tric ati Plumbing Clas Pi oina City of Tukwila BUILDING DIVISION REVISIONS N o changes shall be made to the scope of work without prior approval of Tukwila. Building Division. NOTE: Revisions will require a new plan submittal I and may include additional plan review tees. LEGAL DESCRIPTION APN # 2716000070 LEGAL DESCRIPTION: GATEWAY CORPORATE CENTER PARCEL B OF CITY OF TUKWILA SHORT PLAT NO 89 -1 -SS RECORDING NO 8904120877 SD SHORT PLAT DAF - LOT 7 OF GATEWAY CORPORATE CENTER Mar review approval is subject to errors and omlssions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Reid Copy and co ons is acknowledged: By r Date: CX.,1 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY 2 8 2008 PERMIT CENTER MacDonald-Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206- 763 -9400 Fax: 206- 767 - 6773 www.macmiller.com WA Lic No: MACDOFS980RU EXPIRES: 07 -06 -08 GATEWAY BLDG 7 PHASE 2 12720 GATEWAY DR S TUKWILA WA 98168 SCHEDULES - HVAC ENGINEER: C LEE CHECKED BY: E GEZON D IKERD LAST REVISED: 05 -21 -08 DATE PLOTTED: 05 -21 -08 ISSUE DATE. 05 -22 -08 DRAWING NUMBER: E- 0182- 73862.15 -00 ISSUED FOR CONSTRUCTION SHEET NUMBER: y ,. V [ gte() CD- PERMIT SET 05 -22 -08 REVISIONS: DATE C^. 0 0 I 0 C3 0 CO a Co N z CO 0 >‚ 0 - 0 cn 0 0_ SITE MAP 64" = o VtEvIENNED FOR CODE COMPO.PNCE APPROV - N City Of Tuloilla BUILD114G D EXP DEC 0 3 2008 RECEIVED CITY OF TUKWILA MAY 2 8 2008 PERMIT CENTER MacDonald-Miner FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206-763-9400 Fax: 206-767-6773 www.macmiller.com WA Lic No: MACDOFS980RU CD—PERMIT SET 05-22-08 DATE GATEWAY BLDG 7 PHASE 2 12720 GATEWAY DR S TUKWILA WA 98168 SITE MAP ENGINEER: C LEE CHECKED ET: • GEZON CAD: D IKERD LAST REVISED: 05-21-08 DATE PLOITED: 05-21-08 ISSUE DATE: 05-22-08 DRAWING NUMBER: E-0182 —7386215-00 ISSUED FOR CONSTRUCTION SHEET NUMBER: TMOD1S Q 0 0 I N Cf co co cn 0 0 z uJ LJ- (1) 0 N LLI 0 CO >— LL9 0 LO (.0 00 N) OD 0 LLj 0 01 :22:42 PM, Wednesday, May 21, 2008 1 m --< Om —1 N -n rrn cx E CO 1 II nil 0 cx (ii 1 b rrl CD co co co Cl) C) CJ C7. CAD FILENAME: WA001- -SPS01 JOBS 738 6215 GATEWAY BLDG :7 PHASE 2 — SF 00 ENG DWG SHTS 7386215TM2_01.DWG N Cm O N-J (3) IV - N x O X .. OX . C) -U -U N.3 z C) ( f { _ C z J p - I ;u C I l > :o Fri C) CJ -� (../) l r- 5 ; . C ;:o r'' 4 T f 7-- C) z C) rrl 0 C) 7 Z�" C) -, _I )a FO t C) C cz 5 =1 C —I 1 -rl 6 C_ C z C1,) 1..)..l .() - C . ) C) r. - -J rl C) rr l Y NI - (!) 0 U � j C { I••.,I rTl I . -:. U) C) --I Cj) I - -r-I rrl Y CJ 0 Crl 5 rl :v rr .7 c-- - D rr! rrl C - ) '..:0 0 C- 171 z C CJ r rl N.) CD --' Cxi '0 a ) {) `J 0 N.) IQ - d -U CU z C' z rr� C) rrl 0 z C. . CAN NN 0 X 0 X 4 N 3 a. 0 4 W 0 N X O N X C) C:..) ci N) CO ' (J) cn 0 0 (/) (rl US Cr) X 0 CO Csd C) C C N) CD *1 N) 0 iJ ] 40 F-,\ 1. f 110 f> -n WVT —'128 26 0 `. >A Ni X X N 200 SA \ () f1 , r l -J I ) 220 RA 2 RA NJ NJ C ) ) r.) J 260 FAA, I WT -138 I C5 0 N) 260.. .RA N N N) Y') 4 X -F* J`> C) /1 -.1.. x 20 -F. C) X C')) CX) •te r Jv r ry f 0 Eli 0 C) C-) N:) Cx Co N.3 C) C'• r'`j'••J r�i *J C-Y 0 uV. 04, C:) :( I' 1'•-) CO •s+ Cc: C'r1 Cl C. C)) Co (;.11 C) C:) 0 C:) N 4 u ' u Ni 4' X N J�J CX) u o r � 0 G) NJ 0 C)) CO N-) CD CO e, 00 V Co Ca. C)) C) C..) C I NJ N) (r1 X N) WI N Q X X N N) v CJ .N- N Ns —1 -) / • f•a N X N ) F;a N 4' X N) 4= CO IV r :+ 0 C) Ni .p X N ya C - 0 N +' X N .p N) N CA IV CA 0 X - IJ C, )" N J P N) 0 A - - F. 1 ROOF PLAN - HVAC SCALE: Vs = 1- ° TH2.0 3 5 6 7 8 2 L. LI 'I REPLACE RTU-102 RECONNECT NEW UNIT TO EXISTING NATURAL GAS LINE AND ELECTRICAL SERVICE A—A , H NOT ALL ROOF-MOUNTED EQUIPMENT IS SHOWN. Li - E- I1 P trEEF TON MODEL. CARRIER 48AKTC5DSQCI 1HM. [EXISTING] CARRIER WEATHER MAKER S1NGLE-PACKAGED 60-TON ROOFTOP UNIT. [MI 48DF-064. SFR1ES# 640PA. ( # Y883274. [EXISTING] REPLACE W/ 6C TON NiionFL C.A.RR1ER 48A31060DSV611HM. CARRIER V/ETHER MAKER SINGLE-PACKAGED ROOD I OR UNIT. MODEL# 48TJD014. SERFS # 6010E. SERIAL# 4194030497. [EXISTING] ; SCREEN WALL \ 1 RTU 1 0 1 RIU— 1 02 NO SCALE RTU- I 02 SOUTH ELEVATION OtGZdt D '----11.EWED FOR CODE COMPLIANCE APPROVED JUN - 4 2tIlla CO Of Tu ila ILDING DIVISION A SLAB 71;‘, cc ON RECEIVED ciri OF TUKWILA MAY 2 8 1008 PERMIT CENTER 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206-763-9400 Fax: 206-767-6773 www.macmiller.com WA Lc No: MACDOFS980RU ISSUED FOR CONSTRUCTION SHEET NUMBER: CD—PERMIT SET REVISIONS: 05-22-08 DATE ENGINEER: C LEE CHECKED BY: B GEZON CAD: D IKERD LAST REVISED: 05-21-08 DATE PLOi i EU: 05-21-08 ISSUE DATE: 05-22-08 DRAWING NUMBER: E-0182-7386215- 00 MacDonald-Miller FACILITY SOLUTIONS GATEWAY BLDG 7 PHASE 2 12720 GATEWAY DR S TUKWILA WA 98168 ROOF PLAN AND ELEVATION - HVAC C.7 0 10 N F- Ui (.0 co 0 z w 0 0 (NJ 0 0 >- co N) Ui 0 0 0 0 Ui 0 Ui z Ui 0