Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M08-161 - BOEING #13-03
BOEING #13 -03 10000 EAST MARGINAL WAY S M08 -161 Parcel No.: 0003400021 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: doc: IMC-10/06 CitAbf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 10000 EAST MARGINAL WY S TUKW Contact Person: Name: STEPHANIE JANSON Address: 8657 S 190 ST , KENT WA Contractor: Name: DESIGN AIR, LTD. Address: 8657 SOUTH 190TH ST , KENT, WA Contractor License No: DESIGL *212DG Value of Mechanical: $62,923.00 Type of Fire Protection: BOEING #13 -03 10000 EAST MARGINAL WAY S , TUKWILA WA BOEING COMPANY THE PROPERTY TAX DEPT , PO BOX 3707 M/C 20 -00 Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial MECHANICAL PERMIT DESCRIPTION OF WORK: INSTALL AIR COOLING UNIT PROVIDED BY THE BOEING COMPANY. PIPING AND HVAC RENOVATION EQUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 1 0 0 0 0 0 0 0 * *continued on next page ** • Permit Number: Issue Date: Permit Expires On: M08 -161 06/23/2008 12/20/2008 Phone: Phone: 253 -854 -2770 Phone: (253) 854 -2770 Expiration Date: 03/07/2010 Fees Collected: $854.38 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment M08 -161 Printed: 06-23 -2008 Permit Center Authorized Signature: I hereby certify that I have read and e Signature: Print Name: .% ��� ti e �O v doc: I MC -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 0 governing this work will be complied vktly( whether specified herein or not. • Permit Number: M08 -161 Issue Date: 06/23/2008 Permit Expires On: 12/20/2008 Date: al/ ✓D ed this permit and know the same to be true and correct. All provisions of law and ordinances The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. Date: 6 -ZS-0 r This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M08 -161 Printed: 06 -23 -2008 Parcel No.: 0003400021 Address: 10000 EAST MARGINAL WY S TUKW Suite No: Tenant: BOEING #13 -03 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 5: Readily accessible access to roof mounted equipment is required. 12: ** *FIRE DEPARTMENT CONDITIONS * ** doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS • Permit Number: M08 -161 Status: ISSUED Applied Date: 06/05/2008 Issue Date: 06/23/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 15: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the M08 - 161 Printed: 06 -23 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 17: Local U.L. central station supervision is required. (City Ordinance #2051) • air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 16: The installation of wiring and equipment shall be in accordance with N.F.P.A. 70, Article 760, Fire Protective Signaling Systems. (NFPA 72- 1.3.3) 18: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 19: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 20: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 21: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 22: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 23: These plans were reviewed by Inspector 0700. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** M08 -161 Printed: 06-23 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: doc: Cond -10/06 Print Name: 75 \ (.. Q- `-v 1- Date: G -2 3 -0 5r"" ordinances governing or local laws regulating M08 -161 Printed: 06-23 -2008 SITE LOCATION Site Address: Oe-i r1 'turw1 \c t c I o Tenant Name: Property Owners Name: Th Q Mailing Address: gU Name: "At' P (S«rCp E -Mail Address: 5e -- A@ Des it a sir i a -n Company Name: (1_,\R deer - S G Q () Mailing Address: �(�� X. 3 ipL1 Contact Person: C C Contractor Registration Number:\,_ 0 r - )D 0 E -Mail Address: Contact Person: 'S4 (> ( ) � la nJ 1 CI E -Mail Address: Company Name: 5 , (u 5L Mailing Address: Contact Person: E -Mail Address: CITY OF TUKWIL' Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Q:\Applications\Forms- Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 bh Building Perm . No. Mechanical Permit No. Plumbing /Gas Permit No Public Works Per, No No. (For o j use only) -t Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** ?? King Co Assessor's Tax No.: OU t(� .a9 Ca is io poo 'tg incd (Da Suite Number: Floor: jni New Tenant: E .... Yes j4 ..No (. Cc), City Wa CONTACT PERSON -- who do we con et when your permit is ready to be issued Day Telephone: Mailing Address: LP 5 -] S , «(Y S/ Y /77 City Fax Number: 0 City Day Telephone: Expiration Date: 5 l O % -aa67 State Zip State - g`' (a /31 Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) State 1U Zi 95� Slo Fax Number j3 6,7) ,Vp`j ARCHITECT OF RECORD must be wet stamped by Archlteet of Reeord Company Name: 1- . () L ( ( Mailing Address: d City State Zip Day Telephone: , .)6 (Q - 5 01 R Fax Number: ENGINEER OF RECORD — All plans 'mu u et stamped by Engineer of Re City Day Telephone: Fax Number: State Zip Page 1 of 6 BUILDING PERMIT INFORION 206 -431 -3670 Valuation of Project (contractor's bid price): $ Existing Building Valuation: $ Scope of Work (please provide detailed information): Will there be new rack storage? ❑.... Yes IS` Floor 2°° Floor Floors th asemen Accessory, Structure Attached Garage Detached Garage Attached C pot Detached Carpel Covered Deck Uncovered Deck Provide All Building Areas in Square Footage Below Interior Remodel Addition to Existing Structure ype of ruction per BC verhangs greater than 18 inches) Type of Occupancy per IBC PLANNING DIVISION: Single family building footprin area of the foundation of all structures, plus any decks over 18 inches an *For an Accessory dwellin: irovide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide doc entation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parki : Stalls Provided: Standard: Compact: Handicap: Will there be hange in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x II" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:\Applications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh ❑.. No If yes, a separate permit and plan submittal will be required. ❑ Other (specify) Page 2 of 6 Uiiit.:Type: 4:C.W Piti ;Qryt I Unit Typei —4kq •" " i;: a.' ': ; Qty•: : : Unii•T �' e: i yP Qty ".�.. , Boiler /Compressor:'• ... ..Qty` Furnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0-3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/WalUFloor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling i Incinerator — Comm/Ind <10,000 CFM ECH OI C°'A ��..cc L PERMITS N F O R NIATION - 20`(x431 3 670 _ �pp .. .. .Aw.,. —Z.. S .- .,,.. ,+ a..�.' .. L�.._ .u.n f• .x ...K,' ._ a,i ;n �.�p• ,.-..• .. rt.�NnR- . MECHANICAL CONTRACTOR INF Company Name: �\�� )�k L- Mailing Address: 9 ( 3 1 So ‘ , c 1 0 S Contact Person: \ R fi 1 Phi■ � de5► . n� a11ua Contractor Registration Number: e (31- a 1 a U3k E -Mail Address: Valuation of Mechanical work (contractor's bid price): .S W• - 1g 1 t °D ‘A-6(4- 1 ..-Ct wlaS L Scope of Work (please provide detailed information): .Ii .at 1).! t' 1 ()OAP C , } ,� 4 e ivi� Q,c,rnpa tt4 { vao✓1 Use: Residential: New .... ❑ Commercial: New .... ❑ Replacement .... ❑ Replacement .... Fuel Type: Electric ❑ Gas ....0 Other: Indicate type of mechanical work being installed and the quantity below: gl ar$4 rt_ va -1,1rb t S - 11)&x. ivo-- x & bLLort, 6-1 7 - Lo ,2a Q:WpplicationsWorms- Applications On Lnel3 -2006 - Permit Applintion.doc Revised: 9 -2006 bh C I'QS -- Ci Day Telephone: Fax Number: Expiration Date: state zip 933 -% -xiio Lu l T vaC L Agin. @ ult. 1'l sett g .1 ? vtip gz Page 4 of 6 PERMIT APPLICATION NO Applicable to all permits this%aWii atio`n en Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW ER AUTHO AGENT: Signature: 0-4-6? Q R 4I ( __ Print Name: G,()53I Mailing Address: 3 Co /q07 7� Date Application Expires: lx -s -09 Date Application Accepted: j Q:\Applications'Fonns- Applications On Line U-2036 - Permit Application.doc Revised: 9 -2006 bh Date: /5 & Day Telephone: (� — S61 - / L. a cRifnl Cit State Zip Staff Initials: 4 Page 6 of 6 1 Fixture Type: Qty Fixture Type: ty Fixt `' e Type: Qty Fixture Type: Qty Bathtub or combination bath /shower Drinking fountain or water cooler (per head) Wash ntain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, in 'rect waste Clothes washer, domestic Floor drain Sinks Dental unit, cuspidor Shower, single h d trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain wate ystem — per drain (i de building) Water heater and /or vent Additional medical gas inlets /outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repai r alteration of water pipi and /or water treating e pment Repair or alteration of drainage or vent piping Medical gas piping system erving one to five i is /outlets for specific gas � PLUMBING AND GAS PIPIN( ERMIT INFORMATION - 206 -431 J 70 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: Valuation of Plumbing work (contractor's bid price): $ Valuation of Gas Piping work (contracto 's bid price): $ Scope of Work (please provide detailed info ation): Building Use (per Intl Building Code): Occupancy (per Intl Building Code): Utility Purveyor: Water: Q:\Applications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Sewer: City Day Telephone: Fax Number: Expiration Date: Indicate type of plumbing fixtures and /or gas piping outlets bein nst• ed and the quantity below: State Zip Page 5 of 6 Receipt No.: R08 -01957 Initials: WER User ID: 1655 Payee: DESIGN AIR ACCOUNT ITEM LIST: Description don: Rataint -OR MECHANICAL - NONRES PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Payment Check 83619 854.38 TRANSACTION LIST: Type Method Descriptio Amount RECEIPT Parcel No.: 0003400021 Permit Number: M08 -161 Address: 10000 EAST MARGINAL WT S TUKW Status: PENDING Suite No: Applied Date: 06/05/2008 Applicant: BOEING #13 -03 Issue Date: Account Code Current Pmts 000.322.102.00.0 683.50 000/345.830 170.88 Total: $854.38 Payment Amount: $854.38 Payment Date: 06/05/2008 11:01 AM Balance: $0.00 3291 06/05 9711 TOTAL 854.38 Pri ntars: OA- n5 -2O(18 Project: 60� 13 D3 Type of Insp (J- A-4 tion: ! fi b � . Address: : l t)00J E. 6 ^ R � Calledgy4 a ,r1,,--T W! Special Instructions: J D to Wanted: _ (( �i a /.�.m. p.m. Requester: Phone No: Mk — Ka( INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: f)PrMT (,a ► pLeAf 1 v 1Date: , r II r ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Pro' ct: , Type of.Inspection: Address: 1 00✓ 6, imitt, AA Date Called: Special Instructions: / Date Wanted: 2 - J Requester: Phone No: Z _ INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION C- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3 70 INSPECTION NO. Approved per applicable codes. Corrections required prior to approval. COMMENTS: . Inspector: Date: ` 2 El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: - .ti Prpj�ct� Type of pec>r • • `aJ Address: 100 0 e �t Mt\\ D te 4 1 k, ti4 I Special Instructions: Date Wanted: .._. _ - 4 Requester: Phone No INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. PERMIT NO. (206)431- 12 Corrections required prior to approval. COMMENTS: rb t &_( -1 Inspector( (Date: to • ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 1 Receipt No.: 'Date: COMMENTS: 2 Type of Inspection: ---- oe /t / r / Mt: e If ic 7 Pi4- L- Address: /0000 Suite #: tr., 4/ i/113 Contact Person: . la 1 7 / 7 ig 144 it .7z de - - Ok._ Phone No.: e---7 IZ 5/-/ i ,i9e v4v --- c4 - - - - • / I ) - - 7 41- ■5 1 g - gt - 7"6 5 _. ..,...,...,.______ : . . ..I - 1".6Ait,c_;7 /1- r .1- / /t77 49 dr: (41p_ I / 6- ki -- /A/ er" ill I1271. JZ- 4 6 (.: nit , - k " - I71> A . 4 - : , o 71) 1 , 16 H r . e...4- - -/ - 4) ./ k ii) '-'77-/ (.• ),z • r 6-' ri. r1 to 0 la , -.,. . Project: 3 2 Type of Inspection: ---- oe /t / r / Mt: e If ic 7 Pi4- L- Address: /0000 Suite #: tr., 4/ i/113 Contact Person: . la 1 7 / 7 ig 144 it .7z de - Special Instructions: Occupancy Type: Phone No.: Deeds Shift Inspection: Sprinklers: Fi}e Alarm: Hood & Duct: Monitor: Pre-Fire: Permits: ... - Occupancy Type: INSPECTION NUMBER n Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT Word/Inspection Record Form.Doc 1/13/06 ) PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Corrections required prior to approval. „ insp dor: 64,0„,a,„ z Date: j //o/o8 Hrs.: / $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from thd City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 ji2 LTD ACTIVITY NUMBER: M08 -161 DATE: 06 -05 -08 PROJECT NAME: BOEING #13 -03 SITE ADDRESS: 10000 EAST MARGINAL WAY S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter .# Revision # , After Permit Issued DEPARTMENTS: X10' (vision Public Works ❑ Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Documents/routing slip.doc 2-28-02 *P ERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP c'100 AV/ / Fire Prevention Incomplete APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: n Planning Division ❑ Permit Coordinator DUE DATE: 06 -10 -08 DATE: DATE: Not Applicable Comments: TUES/THURS RO TING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: P_ er`inii'Ceiler.UseOnly'' INCOMPLETE LETTER MAILED: a.? t•• LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DUE DATE: 07 -08 -08 Not Approved (attach comments) ❑ PermitCenter Use Only: CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Business Owner Information Name Role Effective Date Expiration Date HAGEN, RONALD A Cancel Date 01/01/1980 Bond Amount Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #8 TRAVELERS CAS & SURETY CO 103742548 03/07/2002 Until Cancelled $12,000.00 02/28/2002 TRAVELERS Look Up a Contractor, ElectriOn or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. License Information License Licensee Name Licensee Type UBI Ind. Ins. Account Id Business Type Address 1 Address 2 City County State Zip Phone Status Specialty 1 Specialty 2 Effective Date Expiration Date Suspend Date Separation Date Parent Company Previous License Next License Associated License DESIGL *212DG DESIGN AIR LTD CONSTRUCTION CONTRACTOR 600314241 CORPORATION 8657 SOUTH 190TH ST KENT KING WA 98031 2538542770 ACTIVE GENERAL UNUSED 3/7/1979 3/7/2010 MRCCOL *981 JB • Page 1 of 3 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= DESIGL *212DG 06/23/2008 DRAWING INDEX SHEET NO. DRAWING N0. SHEET TITLE REV. NO. DATE Al 13 -03 -A1 TITLE SHEET C 02.22.08 2A01 13- 03 -2A01 COMPOSIT FIRST FLOOR PLAN, EGRESS PATH H 02.22.08 2E10 13- 03 -2E10 LIGHTING PLAN- REFERENCE ONLY E 02.25.08 2A1OR 13- 03 -2A1OR SECOND FLOOR PLAN -- REMOVAL H 02.22.08 2A10 13- 03 --2A10 SECOND FLOOR PLAN H 02.22.08 2A10A 13- 03 -2A10A SECOND FLOOR PLAN- CONSTRUCTION NOTES H 02.22.08 A353 13-03-A353 DOOR SCHEDULE & DETAILS B 02.22.08 A354 13- 03 --A354 SECOND FLOOR PLAN- WALL & FLOOR FINISHES B 02.22.08 A501 13- 103 -A501 WALL TYPES E 02.22.08 1M60 13-03-1M60 • FIRST FLOOR PIPING PLAN D 03.14.08 1M6OX 13-03-1M6OX FIRST FLOOR PIPING PLAN - REMOVAL X 03.14.08 2M10 13- 03 -2M10 SECOND FLOOR HVAC PLAN G 03.14.08 2M10A 13- 03 -2M10A UNDER RAISED FLOOR - 2ND FLOOR HVAC PLAN A 03.12.08 2M60 13- 03 -2M60 SECOND FLOOR PIPING PLAN A 03.14.08 2A10A 13-- 03 -2A10A SECOND FLOOR PLAN- CONSTRUCTION NOTES H 03.14.08 2M110 13- 03 -2M110 SECOND FLOOR PLUMBING PLAN B 03.14.08 2M260 13- 03 -2M260 SECOND FLOOR FIRE PROTECTION PLAN A 01.25.08 M450 13- 103 -M450 PLUMBING DETAIL PLANS E 03.14.08 M451 13-103-M451 MECHANICAL DETAIL PLANS . H 03.14.08 M452 13-103-M452 SECTIONS AND DETAILS E 03.14.08 M506 13- 103 -M506 SECTIONS AND DETAILS (REFRENCE ONLY) D 05.01.06 M507 13-103-M507 SECTIONS AND DETAILS (REFRENCE ONLY) D 04.02.03 _ _ IV \ \COVV ;,\ ® wkt er \ Co \.\- r- SYM A B C B VICINITY MAP. 99 7 -127 KING CIXINTY AIRPORT OFF1C£ CENTER (FAA) 99 FROM DOWNTOWN SEATTLE EAST MARGINAL WAY CORPORATE PARK 599 TUKWILA 960 FROM K & AUBU EOT 157 DEVELOPMENTAL CENTER 900 AREA MAP OXBOW PARKING LOT NO SCALE 13 -03 BUILDING LOCATION 80 • BRIEF PROJECT NARRATIVE DC 03 CHECK BOX B0 -1 \G 9 Ci\ F R 1COOC -AST VARC\AL WAY SOOT T,.....,/<W1LA, WASH\WO\ 98108 GENERAL NOTES CONSTRUCTION SET OF DOCUMENTS, REVIEWED AND STAMPED BY CITY OF TUKWILA MUST BE ON SITE DURING CONSTRUCTION. DO NOT PROCEED. WITH CONSTRUCTION WITHOUT ABOVE MENTIONED SET OF DOCUMENTS. 1. VERIFY ALL DIMENSIONS AND CONNECTIONS BEFORE ANY WORK. 2. NOTIFY FACILITY ENGINEERS SHOULD EXISTING CONDITIONS REQUIRE DESIGN REVISIONS. 3, COORDINATE WORK WITH OTHER CRAFTS. 4. RETURN THIS SAME SET TO GARY TALLER AT BLDG. 9 -51 COL N /1, AFTER COMPLETION OF THIS CONSTRUCTION. PROJECT CHECKLIST • THESE DRAWINGS CONFORM TO THE 2006 I.B.C. CODES AND THE WAC 51 -20 AS ADAPTED OR AMENDED BY LOCAL ORDINANCES AND COMPLIANCE WITH CITY OF TUKWILA ZONING. ❑ ENGINEERING CALCULATIONS ( IF APPLICABLE ) El ROOMS LABELED PER OCCUPANCY PER U.B.C. TABLE 10 -A. IZ BUILDING FLOOR NUMBER ON PRINT FOR AREA OF CONSTRUCTION. NUMBER OF PRINTS REQUIRED FOR PERMIT PACKAGE: ❑ 1. GENERAL PERMIT (SHELL & CORE) 6 SETS OF ENERGY CALCULATIONS 2 SETS OF CIVIL DRAWINGS WITH UTILITIES 2 SETS SOILS REPORTS, STAMPED BY GEOTECHNICAL ENGINEER 2 SETS STRUCTURAL CALCULATIONS 2 SETS PROJECT CONSTRUCTION SPECIFICATIONS 2 SETS TOPOGRAPHICAL SURVEY 2 COPIES OF LEGAL DESCRIPTION 2 SETS OF WORKING DRAWINGS El 2. TENANT IMPROVEMENTS (NON- STRUCTURAL), 4 COMPLETE SETS ❑ 3. MECHANICAL, 2 COMPLETE SETS ❑ 4. FIRE PROTECTION /SPRINKLERS, 4 COMPLETE SETS REPARTITION FROM EXISTING OFFICE SPACE (1) 4914 SQUARE FOOT OFFICE SPACE & (1) 2133 SQUARE FOOT OFFICE SPACE: DEMO APPROX. 120' ---0" TOTAL LINEAR FEET OF 10' -0" HIGH EXISTING DEMOUNTABLE WALL, WALL TRACK, HARDWARE. DEMO (4) DEMOUNTABLE HOLLOW METAL DOORS & ASSOCIATED DOOR FRAMES & HARDWARE. DEMO (2) HOLLOW METAL DOORS & ASSOCIATED DOOR FRAMES & HARDWARE. REMOVE EXITING HARDWARE ON (1) EXISTING DOOR. INSTALL APPROX. INSTALL APPROX. 120' -0" OF NEW FULL HEIGHT STC 50 WALL. INSTALL (4) STC 53 DOORS, (2) HOLLOW METAL DOORS & NEW EXISTING HARDWARE ON (1) EXISTING DOOR. PAINT NEW WALLS & DOOR. NEW RUBBER WALL BASE. AR" -L AWACS 40 G 45 AD REVISION AEW &C SECURE ROOM AWACS 40/45 ADL2 AWACS 40/45 ADL2- REVISION J #556393 -00 J #170567 -00 J #170567 -00 TWH TMH 08.04.05 02.01.08 02.20.08 BY MHW LMC LMC APPROVED DATE SYM REVISION BY APPROVED DATE BOE /NGm ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE ENGINEER O AWN M. DITTMAR CHECKED M. MILLER CHECKED APPROVED APPROVED n DATE 8-10-1999 SUBTITLE R R S 0 CODE SUMMARY LAND USE CODE BUILDING CODES OCCUPANCY. GROUP CONSTRUCTION TYPE FLOOR AREAS: BUILDING FOOTPRINT BUILDING GROSS FIRST FLOOR SECOND FLOOR THIRD FLOOR BUILDING HEIGHT STORIES OCCUPANT LOAD: OFFICES /LABS EQUIP /MECH /STOR OTHER HANDICAPPED REQUIREMENTS FIRE PROTECTION SEPARATION EXTERIOR WALL (NON - BEARING) INTERIOR WALLS (NON-BEARING) INTERIOR WALLS (BEARING) STRUCTURAL FRAME FLOORS STAIRS ENCLOSURES SHAFT ENCLOSURES ELEVATOR SHAFT CORRIDORS ROOF ROOFING CONSTRUCTION SEISMIC ZONE 3 1/100 S.F. 1/300 S.F. 1/100 S.F. TUKWILA (M -2) 2006 I.B.C. CODES AND THE WAC 51 -20 AS ADAPTED OR AMENDED BY LOCAL ORDINANCES, AND COMPLIANCE WITH CITY OF TUKWILA ZONING. GROUPS B OFFICE & ELECTRONIC WORK AREA TYPE II -B SEPARATION 60 FEET (MINIMUM ALL SIDES) 19,058 S.F. (INCLUDING CANOPIES) 55,518 S.F. 19,058 S.F. 18,230 S.F. 18,230 S.F. 50' -6" FT. 3 FIRST FLOOR SECOND FLOOR THIRD FLOOR BUILDING TOTAL 89 106 113 308 ALL WORK SHALL COMPLY WITH CHAPTER 51 -20 WAC; UBC CHAPTER 11 ACCESSIBILITY AND ALL ADA ACCESSIBILITY GUIDE LINES. FULLY AUTOMATIC THROUGH -OUT F/S CLASS N/A >30' =0 0 0 0 0 1 -HOUR 1 -HOUR 1 -HOUR >30 OCCUPANTS = 0 w /SPRINKLERS 0 FIRE RETARDANT CLASS A (FM CLASS 1) ARCHITECTURAL MASTER REVISIONS No c hanges shall be made to the scor+P of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. SEPARATE PERMIT REQUIRED FOR 0 Mechanical DirElectrical fir Plumbing I'Gas Piping City of Tukwila BUILDING DIVISION TITLE SHEET BUILDING 13 -03 COL.- FILE COPY Permit No. Plar review approval Is subIect to effort arid omissions. Approval of construction documents does not authorize the violation Of any adopted code or own'. Receipt of approved Copy and conditions is a owteded: D.0 By Date: SHEET t1O8 JOB NO. DWG NO. City of Tukwila BUILDING DIVISION CURRENT REVISION J #170567 -00 Al SYMBOL 170567 -00 13 -03 —A1 RECEIVED JUN 052008 PERMIT CENTER DATE COMP NO. 02.22.08 LEGEND: GENERAL NOTES: 1. EMERGENCY LIGHTING ALONG COMMON PATH OF EGRESS TRAVEL TO .COMPLY WITH SECTION 1006.4 OF 2006 IBC. SYM A C D F ISSUE FOR CONSTRUCTION HOIST REVISION REVISION GENERAL REVISIONS & MANBARS AIL EQUIPTMENT LOCATION CHANGE ADD FIRE /SMOKE DAMPERS - DCN 53 MOD IBC 2006 2790 S.F., S.F PER MOD AIL: OFFICE SPACE B OCCUPANCY- OFFICE 28 OCCUPANTS AT 100 OCCUPANT PER TABLE 1004.1.1 ADL2: OFFICE SPACE IBC 2006 B OCCUPANCY- �FFICE 383 S.F., 4 OCCUPANTS A 100 S.F PER OCCUPANT PER ABLE 1004.1.1 29 OCCUPANTS AIL: OFFICE SPACE IBC 2006 B OCCUPANCY- OFFICE 4914 S.F., 50 OCCUPANTS AT 100 S.F PER OCCUPANT PER TABLE 1004.1.1 28 OCCUPANTS ES DOOR XIT DOOR EX' AC DOOR FIRE RATED CORRIDOR CESS DOOR EXIT DOO 40 OCCUPANTS ADL2: OFFICE SPACE IBC 2006 B OCCUPANCY- OFFICE 2133 S.F., 22 OCCUPANTS AT 100 S.F PER OCCUPANT PER TABLE 1004.1.1 40 OCCUPANTS r=1/ EXI CESS DOOR 1Z+ lbw IN WWI KIM ADL2: OFFICE SPACE IBC 2006 B OCCUPANCY- OFFICE 125 S.F., 2 OCCUPANTS AT 100 S.F PER OCCUPANT PER TABLE 1004.1.1 ADL2: OFFICE SPACE U ANCY- OF 218 S.F., 3 OCCUPANTS A 100 S.F PER OCCUPANT PER TABLE 1004.1.1 BY SCC SCC SCC SCC SCC FORKLIFT ACCESS ONLY APPROVED WEM WEM WEM WEM DATE 03.14.96 03.26.96 08.12.96 08.23.96 11.07.96 SYM G H AWACS 40/45 ADL2 REVISION AWACS 40/45 ADL2- REVISION J #170567 -00 J! 170567 -00 SECOND FLOOR P BY LMC LMC APPROVED DATE 02.01.08 02.22.08 FORKLIFT ACCESS _ONLY LA\ g ACCEPTAB THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN L. REYNOLYDS CHECKED B. ESLICK ENGINEER S. CRUSE CHECKED 5. CRUSE APPROVED W. E. MOOR APPROVED K. RAMBALDINI DATE 03.26.96 SUBTITLE TITLE 3 SECOND FLOOR EGRESS PLAN AWACS 40/45 ADL2 BUILDING 13 -03.2 ARCHITECTURAL MASTER COL. A -F/1 -7 DEV. CENTER, WA CODE COMPLIANCE APPROVED JUN 1 2000 City Of �i1kwila 131 IDG - IS ON CURRENT REVISION 4170567-00 SHEET JOB NO. DWG NO. 2A01 SYMBOL 170567 -00 13- 03 --2A01 RECEIVED JUN 0 5 2Q08 PERMIT CENTEF DATE COMP NO. 02.22.08 • _As, .1111111 Hommmo 67: • NO.1 is dliak"&. .n 11••;11 Iu • Mow Mk • Alk r! 1 , . IF 1 _ r 4 ■till -- : ra '_"" I I�� I aII_..e E � I _ : -1 ■ - -■ ■rr -■ I�..rI1I UP 2A10 A203 (202 l 9 , -8 " 210B4 2A10 A208 ELEVATOR LOBBY 228B5 ELEVATOR # 6 ELEVATOR #2 RT oR (216B4) 1BS i, 231 B' 4 RECYCLE 22705 Iti 19' -6" APPROX. 4' -6" 14' -2" (207E3) 0 CC O• 0 U 9 ' t6 " 132) ■t 2038 1 � '/1, ik L mini■ ■■ ■� ■■■ ■ ■■■ ■ ■ ■ ■ ■ ■ ■■\' 1 s■ - 20 c2 efil Blum ■: gam:;■■■ ■ ■ ■ ■ ■emme� ■ ■ ■ ■ ■ ■ ■■w. ii�� �i■1■■ m����� ■■■■■■ ■`J■■ ■.�.r�■■■■ ■ ■ ■ ■NeI rlitimmtimmilrifonsammummummmummonavi rE -7” - », II co N 41' -0" 1 BS MEN 225C5 Fl 1 BS 0 F F 11" 23005 bib 5' -7" ar i I • ,=Cil EMI NIB ���� ■� 1 ii6sa - 1017 29C ul 41t 0 N) 1 SER CE COUN ER WOMEN 22305 AR E 0 4C5 B- N N N 7'-2" DATA COMMUNICATION 221D5 BS BS D5 AMU 1 B az.adb irgya p 0 219 10 A371 COUNTER BS 1 4 4.* 4" 12' -4" BS 11'- -2 1/4" 209E3 ■■ 4' -10u' 210E4 -c? 11 5111 MECHANICAL CHASE r • 0 0 0 C MECHANICAL 1'-- -6 1/2" CHASE MECHANICAL CHASE TEST DATA CONTROL 220D6 GATE (224E5) JTIDS 11' -0" 220E4 223E6 BS 4 TWAY 8E3 kg i W1 �:I D UP AS MEETING ROOM OFFICE 216E5 OFFICE 217E6 �■■■11.1I 1 205E3 NO.2 N0.3 2A10 A202 N W K 0 16' -0" 2A10 A202 2A10 AA451 201A2 16' - 2A10 A453 2A10 2A10 A208 2A10 A207 A203 229B4 226C5 1 ► _ dil 1 - 741t r-- MECHANICA► CHASE Al I gib 2A10 A210 i 6' -O" 1 6'-O" 202D1 2A10 A111 • 2A10 A200 2A10 1 • • • 2A10 A200 2A10 A110 2A10 A454 2A10 A201 0 STORAGE N STAIR STAIR 2A10 2 2A10 A201 Q N A452 2A1 SYM A B C D F 2A10 A207 STAIR ADD FIRE /SMOKE DAMPERS -- DCN 53 2A10 A208 CANOPY BELOW SCC WEM 11.07.96 2A10 A208 160' -0" (5 AT 32' -0 ") 1A101A204 CANOPY BELOW - APPROVED K. RAMBALDINI SIM. OPP. A208 03.26.96 A45 THIS 21' -2" SECTION OF 10' -0" HIGH DEMOUNTABLE WALL TO REMAIN. 8> THIS 14' -2" SECTION OF 10' --0" HIGH DEMOUNTABLE WALL TO REMAIN. DEMO 41' -0" EXISTING FLOOR TO FLOOR 4" THICK STUD & GWB WALL. 1 DEMO THIS 3' -9" SECTION OF EXISTING FLOOR TO FLOOR 4" THICK STUD & GWB WALL. DEMO THIS 4' --10" FULL HEIGHT SECTION OF EXISTING FLOOR TO FLOOR 6" THICK STUD & GWB WALL. DEMO THIS 3' -8" FULL HEIGHT SECTION OF EXISTING FLOOR TO FLOOR 6" THICK STUD & GWB WALL. THIS 13' -8 1/2" SECTION OF EXISTING TRUE HEIGHT WALL & WALL MOUNTED ELECTRICAL EQUIPMENT TO REMAIN UNLESS OTHERWISE NOTED IN ELECTRICAL /MECHANICAL DRAWINGS. THIS 21' -3" SECTION OF EXISTING TRUE HEIGHT WALL TO REMAIN. DEMO EXISTING WOODEN LEDGE. REMOVAL ARCHITECTURAL MASTER COL. A -F/1 -7 DEV. CENTER, WA LEGEND: DWG NO. RECESSED FIRE HOSE AND FIRE EXTINGUISHER CABINET (COMBINATION) GENERAL NOTES: SUGGESTED AREA OF REMOVAL FOR CEILING TILE & GRID SYSTEM & /OR ACCESS FLOOR TILE & PEDESTALS AS NEEDED TO ACCOMMODATE DEMOLITION & CONSTRUCTION. WALL TO BE REMOVED. WALL TYPE, SEE SHEET A501 ITEM SPECIFIC NOTE NOTE APPLIES TO CONSTRUCTION AREA. 1. OPEN OFFICE SPACE IBC 2006 BUSINESS OCCUPANCY B- OFFICE. APPROX. 7,658 S.F., 77 OCCUPANTS AT 100 S.F. PER OCCUPANT PER TABLE 1004.1.1 2. COORDINATE WORK WITH ALL TRADES REQUIRED TO COMPLETE THE WORK. 3. LEAVE WORK & STAGING AREAS CLEAN & UNCLUTTERED AT THE END OF EACH DAY & THE END OF THE JOB. 4. REMOVE ALL DEMOLISHED MATERIALS FROM BOEING PROPERTY. 6. REMOVE ALL TOOLS & MATERIALS FROM THE WORK AREA. 7. NO CHANGES SHALL BE MADE TO THE DRAWINGS WITHOUT WRITTEN APPROVAL BY THE FACILITIES ENGINEER RESPONSIBLE FOR THAT PORTION OF THE WORK. 8. WALL TYPES, REFER TO SHEET A501. 9. REMOVE & SURPLUS ALL ITEMS FROM WALLS, UNLESS OTHERWISE NOTED. 10. REMOVE ALL (APPROX. 775 LINEAR FEET) EXISTING ROPPE 4" RUBBER WALL BASE 11. DEMO ALL EXISTING DAMAGED OR MIS- MATCHED 2' X 4' ACOUSTICAL CEILING TILES. ASSUME APPROX. 10% OF TOTAL AREA. 12. ALL EXISTING HVAC REGISTERS & VENTS TO REMAIN UNLESS OTHERWISE NOTED. 13. EXISTING CEILING GRID, SPEAKERS & ALL SPRINKLER HEADS TO REMAIN UNLESS OTHERWISE NOTED. REMOVAL NOTES: REMOVE & STORE APPROX. 815 SQUARE FEET OF EXISTING ACCESS FLOOR TILES & FLOORING PEDESTALS & ACOUSTICAL CEILING TILES & GRID SYSTEM AS NEEDED TO ACCOMMODATE EXISTING WALL DEMOLITION FOR NEW TRUE HEIGHT WALL CONSTRUCTION. SEE AREA AS SUGGESTED BY HATCH. DEMO EXISTING PAIR OF 7' HIGH DOORS, DOOR FRAMES & HARDWARE. (DOOR #214C4) DEMO EXISTING DEMOUNTABLE 3' WIDE X 7' HIGH DOOR, DOOR FRAME, & HARDWARE. (DOORS #212C3, #204C2, #213C3, & #203B2) DEMO EXISTING 3' -O" WIDE X 7' -0" HIGH DOOR, DOOR FRAME, AND HARDWARE. (DOOR #216B4 & 211C3) DEMO EXISTING CRASH BAR DOOR HARDWARE ONLY. DOOR, FRAME & ALL OTHER DOOR HARDWARE TO REMAIN. (DOOR #210E4) DEMO APPROX. 120' -10" TOTAL LINEAR FEET OF 10' --0" HIGH EXISTING DEMOUNTABLE WALL, CEILING TRACK, HARDWARE & WALL BASE (BOTH SIDES). DEMO TO EXPOSED STEEL COLUMN. RECEIVED JUN 05 2008 LRMI UENTEI- SCALE: 1/8"=1'-0" REVISION BY ISSUE FOR CONSTRUCTION HOIST REVISION SCC SCC GENERAL REVISIONS & MANBARS SCC AIL EQUIPTMENT LOCATION CHANGE SCC APPROVED WEM WEM WEM DATE 03.14.96 03.26.96 08.12.96 08.23.96 SYM G H REVISION AWACS 40/45 ADL2 AWACS 40/45 ADL2 -- REVISION J #170567 -00 J #170567 -00 BY LMC LMC APPROVED DATE 03.17.08 02.22.08 SYMBOL R -00 13- 03 -2A1OR DATE COMP NO. 02.22.08 co 0 ISSUE FOR CONSTRUCTION HOIST REVISION REVISION GENERAL REVISIONS & MANBARS AIL EQUIPTMENT LOCATION CHANGE ADD FIRE /SMOKE DAMPERS -- DCN 53 2A10 A207 STAIR I NO.1 2A101A202 2A10 M451 APPROVED ( 2A10 A208 MOD AIL 201A2 03.14.96 03.26.96 08.12.96 08.23.96 11.07.96 2A10 A353 2A10 A353 12' -0" (,, 2A10 M A353 225C5 FIRE CAB. 23005 2A10 M450 MECHANICAL 1'-6 1/2" CHASE MECHANICAL CHASE TEST DATA CONTROL 220D6 221D5 ° PA10 A371 COUNTER GATE SERVICE COUNTER (224E5 JTIDS 218E5 JANITOR 22405 22305 ADLL2: OFFICE SPACE IBC 2006 B OCCUPANCY- OFFICE 2133 S.F. 22 OCCUPANTS AT 100 S.F PER OCCUPANT PER TABLE 1004.1.1 21404 SEC. STOR. 211 E4 22805 STORAGE 209E3 MECHANICAL CHASE 210E4 220E4 HOISTWAY MEETING ROOM OFFICE 217E6 OFFICE 1 216E5 21.203 C$ ifi X k - \I .Oi ■■■■■1■■■►" Cali e� p• — ter.. i_..z=,_dur rawimi v i�1I■I■I■■■■1■■■ wouta ■■ <<.,_.�i ii■ mi■■ilmr ■na!�►.a■■■■■ immmEnstr Amy im igni ■ 21001:1111•••. .i ■■ ■ail ■/ ,90103 r' r6 �I 6' -8" 16' --O o ■ ■■I ;, ©© ■u ■I ■ ■ ■■■■ ■■ ■■ ■■■■ ■ ■ ■■■l� ■■ ■I ■A ■1M1■■ ■■ ■ ■ ■1■■■■■I■ri■ il CM■11111111111111111111111111111111111111011 ■.ilIU 1 riot 205E3 2A10 04 2A10 A20 gin) FIRE CAB. immmEMMEMMEMEMMEmms G AWACS 40/45 ADL2 H AWACS 40/45 ADL2 2A10 A208 ELEVATOR LOBBY 228B5 2A10 A453 REVISION CORRIDOR 210B4 ELEVATOR # ELEVATOR #2 2A10 A208 CORRIDOR — VENDING COFFEE 22605 RECYCLE 4170567-00 J #170567 -00 SECOE\ 2A10 A207 APPROVED 02.01.08 02.22.08 D FLOOR P_,\ e;L ArizEzAva ° Al `_: OFFICE SPACE IBC 2006 B OCCUPANCY- OFFICE 4914 S.F., 50 OCCUPANTS AT 10 S.F PER OCCUPANT PER TABLE 1004.1.1 2A10 A208 1A10 A204 CANOPY BELOW - ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN L. REYNOLYDS CHECK D B. ESLICK E INEER S. CRUSE CHECKED S. CRUSE APPROVED W. E. MOOR APPROVED K. RAMBALDINI 03.26.96 SUBTITLE SIM. OPP. A208 2A10 A110 2A10 A454 2A10 A201 STORAGE I STAI R STAIR 2A10 A201 ARCHITECTURAL MASTER SECOND FLOOR PLAN AWACS 40/45 ADL2 LAB BUILDING 13 -03.2 COL. A -F/1 -7 LEGEND: GENERAL NOTES: 1. REFER TO SHEET 2A10A FOR GENERAL & CONSTRUCTION NOTES. DEV. CENTER, WA RECESSED FIRE HOSE AND FIRE EXTINGUISHER CABINET (COMBINATION) SUGGESTED RAISED ACCESS FLOOR & PEDESTAL & /OR CEILING TILE & GRID SYSTEM AREA TO BE REINSTALLED AS WAS EFFECTED BY DEMOLITION /CONSTRUCTION. WALL TYPE DESIGNATION, SEE SHEET A501 NEW FULL HEIGHT STC 49 WALL. DOOR DESIGNATION. SEE DOOR SCHEDULE SHEET A353. ROOM DESIGNATION. ITEM SPECIFIC NOTE NOTE APPLIES TO CONSTRICTION AREA. CURRENT REVISION J # 170567 -00 SHEET 2A1 DWG NO. SYMBOL 13- 03 -2A10 COMP NO. 02.22.08 SYM A B C D F ISSUE FOR CONSTRUCTION HOIST REVISION REVISION GENERAL REVISIONS & MANBARS AIL EQUIPTMENT LOCATION CHANGE ADD FIRE /SMOKE DAMPERS -- DCN 53 BY SCC SCC SCC SCC SCC APPROVED WEM WEM WEM WEM DATE 03i 4.96 03.26.96 08.12.96 08.23.96 11.07.96 SYM G H AWACS 40/45 ADL2 REVISION AWACS 40/45 ADL2- REVISION J #170567 -00 J #170567 -00 BY LMC LMC APPROVED TWH DATE 02.01.07 02.22.08 e ® ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE 10 NEW DOOR: 201E4 A) PREP WALL TO ACCEPT INSTALLATION OF STC 53 DOOR. INSTALL (1) 16 GA, KING STUD, FLOOR TO FLOOR, EACH SIDE OF DOOR FRAME. INSTALL 4 PIECE 16 GA. STEEL STUD HEADER. B) INSTALL SINGLE KRIEGER, 3'--0" X 7' -O" NOMINAL RH STC 53 HOLLOW METAL DOOR FRAME (THROAT 7 1/8"), DOOR & HARDWARE. FACTORY PREPPED FOR HARDWARE. C) GROUT FRAME SOLID. DRAWN L. REYNOLYDS CHECKED B. ESLICK ENGINEER 5. CRUSE CHECKED S. CRUSE APPROVED W. E. MOOR APPROVED K. RAMBALDINI NEW DOOR: 202E4 A) PREP WALL TO ACCEPT INSTALLATION OF STC 53 DOOR. INSTALL (1) 16 GA, KING STUD, FLOOR TO FLOOR, EACH SIDE OF DOOR FRAME. INSTALL 4 PIECE 16 GA. STEEL STUD HEADER. B) INSTALL SINGLE KRIEGER, 3' -0" X 7'--0" NOMINAL RHRB STC 53 HOLLOW METAL DOOR FRAME (THROAT 7 1/8"), DOOR & HARDWARE. FACTORY PREPPED FOR HARDWARE. C) GROUT FRAME SOLID. NEW DOOR: 214C4 A) PREP WALL TO ACCEPT INSTALLATION OF STC 53, 20 -MIN FIRE-RATED DOOR. INSTALL (1) 16 GA, KING STUD, FLOOR TO FLOOR, EACH SIDE OF DOOR FRAME. INSTALL 4 PIECE 16 GA. STEEL STUD HEADER. B) INSTALL SINGLE KRIEGER, 4' -0" X 7' -O" NOMINAL RH STC 53 HOLLOW METAL DOOR FRAME (THROAT 7 1/8"), DOOR & HARDWARE. FACTORY PREPPED FOR HARDWARE. C) GROUT FRAME SOLID. NEW DOOR: 201C3 A) PREP WALL TO ACCEPT INSTALLATION OF PAIR OF STC 53 EMERGENCY EXIT DOORS. INSTALL (1) 16 GA, KING STUD, FLOOR TO FLOOR, EACH SIDE OF DOOR FRAME. INSTALL 4 PIECE 16 GA. STEEL STUD HEADER. B) INSTALL DOUBLE KRIEGER, 6' -0" X 7--Q" NOMINAL LH & RH STC 53 HOLLOW METAL DOOR FRAME (THROAT 7 1/8"), DOORS & PANIC HARDWARE. FACTORY PREPPED FOR HARDWARE. C) GROUT FRAME SOLID. D) INSTALL LIGHTED EXIT SIGN AT PUSH SIDE OF DOOR. NEW DOOR 203E4: A) PREP WALL TO ACCEPT INSTALLATION OF STC 53, 20 -MIN FIRE -RATED DOOR. INSTALL (1) 16 GA, KING STUD, FLOOR TO FLOOR, EACH SIDE OF DOOR FRAME. INSTALL 4 PIECE 16 GA. STEEL STUD HEADER. B) INSTALL SINGLE KRIEGER, 4' -0" X 7-0" NOMINAL LHRB STC 53 HOLLOW METAL DOOR FRAME (THROAT 7 1/8"), DOOR & HARDWARE. FACTORY PREPPED FOR HARDWARE. C) GROUT FRAME SOLID. D) INSTALL "NOT AN EXIT SIGN AT BOTH SIDES OF NEW DOOR HARDWARE, DOOR 210E4: A) EXISTING 20 -MIN FIRE -RATED DOOR TO REMAIN. B) NEW HARDWARE: CLOSER, LEVER LATCH UNICAN, KABA MASS CDX & MANUAL PANIC BAR, SMOKE SEALS, CLOSER & FLOOR STOP. 16 INSTALL CORRESPONDING BOEING PROVIDED COLUMN NUMBER SIGNAGE 6" BELOW CEILING GRID. CENTER ON COLUMN. INSTALL ON THIS SIDE OF COLUMN. INFILL WALL AT SITE OF DOOR REMOVAL. WALL ASSEMBLY TO MATCH EXISTING CONDITIONS. WALL BASE PER EXISTING CONDITIONS. PREP FOR PAINT. EXISTING 13' -1 1/2" SECTION OF TRUE HEIGHT WALL & WALL MOUNTED EQUIPMENT TO REMAIN UNLESS OTHERWISE SPECIFIED IN ELECTRICAL DRAWINGS. DATE 03.26.96 SUBTITLE TITLE ARCHITECTURAL MASTER \ NO * IA CO 1� ®y� �vN ! ;\a „OCIO AWACS 40/45 ADL2 BUILDING 13 -03.2 COL. A -F/1 -7 SECOND FLOOR CONSTRUCTION NOTES GENERAL NOTES: 1. COORDINATE WORK WITH ALL TRADES REQUIRED TO COMPLETE THE WORK. 2. LEAVE WORK & STAGING AREAS CLEAN & UNCLUTTERED AT THE END OF EACH DAY & AT THE END OF THE JOB. 3. REMOVE ALL DEMOLISHED MATERIALS FROM BOEING PROPERTY. 4. REMOVE ALL TOOLS & MATERIALS FROM THE WORK AREA. 5. NO CHANGES SHALL BE MADE TO THE DRAWINGS WITHOUT WRITTEN APPROVAL BY THE FACILITIES ENGINEER RESPONSIBLE FOR THAT PORTION OF THE WORK. 6. WALL TYPES, REFER TO SHEET A501. 7. ALL NEW STUD WALLS 'OTHER THAN DEMOUNTABLE PARTITIONS EXTEND THROUGH THE RAISED ACCESS FLOOR TO CONCRETE FLOOR DECK BELOW & EXTEND UP THROUGH CEILING GRID TO DECK ABOVE. CLARIFICATION: GWB /STUD WALLS TO RUN UNDER DOORWAY SILLS AT ALL FULL HEIGHT WALLS PENETRATING THE ACCESS FLOOR TO THE CONCRETE FLOOR DECK. 8. ALL EXISTING LIGHT FIXTURES TO REMAIN UNLESS OTHERWISE NOTED. SEE ELECTRICAL DRAWINGS. 9. ALL EXISTING CEILING TILES TO REMAIN UNLESS OTHERWISE NOTED. 10. EXISTING CEILING GRID, SPEAKERS & ALL SPRINKLER HEADS TO REMAIN UNLESS OTHERWISE NOTED. SEE MECHANICAL DRAWINGS. 11. ALL EXISTING HVAC REGISTERS & VENTS TO REMAIN UNLESS OTHERWISE NOTED. SEE MECHANICAL DRAWINGS. 12. FOR ALL DOOR, DOOR FRAME & DOOR HARDWARE SPECIFICATIONS, AS WELL AS DOOR & DOOR FRAME (FINCHES SEE DOOR SCHEDULE SHEET A535. 13. FOR ALL WALL & FLOOR FINISHES SEE SHEET A354 14. REPLACE ALL MISSING, DAMAGED, OR MISMATCHED 2' X 4' ACOUSTICAL CEILING TILES. ASSUMING APPROX. 5% OF TOTAL AREA. CONSTRUCTION NOTES: AT THE CONCLUSION OF CONSTRUCTION, MODIFY & REINSTALL APPROX. 815 SQUARE FEET OF EXISTING ACCESS FLOOR TILES & FLOORING PEDESTALS & ACOUSTICAL CEILING TILES & GRID SYSTEM WHICH WAS PREVIOUSLY REMOVED TO ACCOMMODATE EXISTING WALL DEMOLITION FOR NEW TRUE HEIGHT WALL CONSTRUCTION. SEE AREA AS INDICATED BY HATCH. 4" HIGH NEW ROPPE RUBBER WALL BASE ON BOTH SIDES OF NEW WALL, COLOR "FAWN." (TYP. AT NEW WALLS.) NEW WALL: STC 49 TRUE HEIGHT WALL, CONCRETE FLOOR TO METAL CEILING DECK ABOVE. CEILING GRID IS 10' ABOVE RAISED FLOOR. TAPE SAN D & PREP WALL FOR FINISHES. CENTER WALL ON COLUMN LINE/ GRID LINE 3. (2) 16 GA. FULL HEIGHT KING STUDS AT EACH SIDE OF DOOR FRAME TO SUPPORT NEW STC53 DOOR(5). EXISTING SECTION OF DEMOUNTABLE WALL APPROX. 4' -6" • WIDE X 10' -O" HIGH TO REMAIN. EXISTING WALL MOUNTED ELECTRICAL EQUIPMENT TO REMAIN & REMAIN OPERATIONAL DURING CONSTRUCTION. FABRICATE .& INSTALL 10' -0" HIGH 2" X 9 1/2" X 2' (PER SITE MEASUREMENTS) STAINLESS STEEL "Z" SHAPED GUARDS TO CAP AT BOTH ENDS OF EXISTING DEMOUNTABLE WALL PORTION. PAINT PER WALL FINISH. NEW WALL: FLUSH WITH EXISTING TRUE HEIGHT WALL. NEW COLUMN SURROUND: STC 49 TRUE HEIGHT COLUMN SURROUND, CONCRETE FLOOR TO METAL CEILING DECK ABOVE. COLUMN SURROUND. TAPE SAND & PREP WALL FOR FINISHES. SEE CORRESPONDING COLUMN DETAIL. FABRICATE & INSTALL 2-1/2" X 2-1/2" X 4' STAINLESS STEEL CORNER GUARD WHERE INDICATED. (TOTAL OF 16 CORNER GUARDS) DEV. CENTER. WA CURRENT REVISION 4170567-00 JOB NO. DWG NO. SYMBOL SHEET 2AIOA 170567 -00 13- 03 -2A1OA DATE RECEIVED JUN 0 5 2000 !'ERMIT CENTER COMP NO. 02.22.08 DOOR HARDWARE . f HARDWARE GROUPS 'I 2 3 4 5 6 7 8 9 1 1'I '12 13 14 NAME • DOOR NUMBERS 201E4 ' 202E4 T 214C4 201C3 203E4 NOT USED _ 210E4 __.._.__ __.._._ . . .. - - COMMENTS 201E4 1A10 SECURED STORAGE 3' -O" 7' -O" NEW NONE 1 SND1 j _ ^. ___ SND1 7 -1/8" - 1/A353 STC-53, 1. 202E4 1A10 LOBY 3' -O" 7' -0" NEW NONE 2 -- - -- 1 SND1 7 -1 /8" -- 1/A353 STC-53, 1. 201C3 1A10 AIL 6' -0" 7' -0" # OF HARDWARE GROUPS 1 2 1 1 0 1 0 0 0 0 0 0 0 0 6 • HARDWARE ITEMS # OF ITEMS REQ'D FOR EACH HARDWARE GROUP 20 MIN # OF ITEMS TO BE SUPPLIED 1 HINGES: STANLEY FBB179 4- 112x4 -1/2 NRP US26D � r v : ..,,.: { 1, s �?1 .,,. . -. -; ... �4 .'-S. '3 , r F . c ; SST .... _ .,....,_ ! .: r� > , e C } '�. . , > � Y ... . , _� . �� r s F F� 5 r • ;.� 4 3 HINGES: BY DOOR FABRICATOR ;:X, X. 3.X :T:53',4,-. :; r ZO1B2 1A10 C 3' -0" 7' -0" S NONE NONE 4 KICKPLA C U 8 SERIES 10 "x34" STAINLESS " C. z - t-- ' Y" ' i � -�i : � w : ni : ; - x q ] �i 3 � 210E4 G � P'' a S � � yY i x ?r �a --+.s 6 A KICKPLATE: QUA 48 SERIES 10"x46" Q STAINLESS .: + �, � y.n a' dki Y - rY ' f7. �.. .� � h .�;• - ' r + rI ;� , y. 4 .�� � ��_ »�. ��. <�. -�r'� 6 CLOSER: NORTON 75006E US26D . : 5 'T.. _ b ;Sr _� :� f. Vx�. �s .' ^L ' �� �:�:s:.r _ � �' _. f ' 1 ; � s�'I_h >.... [ 1•::. - ; .. ; { y .� 1<. 2' z1 �. 'L -, 1. G.�i.._. i3 T °� =• 2 7 • CLOSER: LCN 4040 SUPER SMOOTHIE W /AUX STOP 120 DEG. HOLD OPEN ARM :1 f _ -1 . ._. J 3 7a .3 - 33 } ,•' F te . ye s }J Zr Y . _ S k ur ,3 }�. GENERAL A. PROVIDE ALL HOLLOW @EACH _ FRAMES . ti X y' .. r � K µ .e F, .. �.. �. � .._ y .r u 1 ... _:`. L _ W /DBL 5 p. 8 LOCKSET LEVER: PASSAGE 1 FUNCTION YALE AU5401xUS26D r :Y 1�, 3�y+� ,t _, T ;� ,:- ^' V1 mi ... ;• 3.,� x '� �.:r \ a _ • r, s} �. �. r _. ", tn , 2.�. 's •a z _� mss, � j f. D 10 LR- 1031 -M -26D NO KEY OVERRIDE) ( FACTORY HANDED UIVICAN, 3/41N LATCH BOLT i �.1 • ^ � „1 �' '� s y r� ;�.� 4 ,� ��Y- 2 �, x ._ r .E. : =-i'1. � �� 'S ,;1� . 1 a ,{ , ...., Lx S ��.. .7 a ^�. y; :�� a- � ... } k , �z -� f r , 1 . n .. 1n �� :.5 .F " ..R . :�- �OV r >: r; - .. 4 KABA -MAS CDX.09 SPIN DIAL DEAD BOLT t 5 x , ? ;, 5F fi �a rm � .� 1 n F l! r c r f 1 . 1 12 - KABA -MAS CDX 09 SPIN DIAL STRIKE TYPE #2 ; : S � • r 1 • '.. y rt i )po4s, e s _ Y kr . + -a..•n r`'.` x � F a..'R .. Y . s xY •• � .. 4 , SJ, I ... _ N r ... � . R F K ..a F S T,1 3 14 SMOKE SEALS: PEMKO S88D17 1 ' 4 • f: " 5 � � 1 h ' S '( ' '� _ " , _ 2 18 EXIT RIM DEVICE W /LEVER HANDLE: LHR DOOR SWING VON DUPRIN 36" ' XP99L -NL -F US26DG F y' r. I ti.. ` . 5 F ;� tp X41 r f ` a` s �� t k z ;- r r r r r t •c; r K. : =: 1 19 EXIT RIM DEVICE W /LEVER HANDLE : LHR DOOR SWING, VON DUPRIN 36" XP99L -NL US26D f E_ i . Fr h t-- - -_ - i _- - - - , SIDE OF DOOR. SIDE OF DOOR. 1 19 E)4T RIM DEVICE W /LEVER HANDLE . RHR DOOR SWING, VON DUPRIN 36" XP99L -NL US26D x - �, )r ; s. ��i 4 r ° ^ z t c s 1 20 EAX500 DETEX BATTERY OPERATED EXIT ALA - C OUNTED RM SURFA E M �; c :. e zs r �: a J is ', y, y ° r .7 s i i 0 21 RHRB SWING. KABA -MAS #511037- 501025 CDX -09 W /RIM EXIT DEVICE. INCLUDES LEVER HANDLE W /RIM CYLINDER AND SURFACE MOUNTING PLATE. MANUAL PANIC BAR OPERATION. .� i 55qq � n V'h ;'Y)1'• `LYA r3 � r k h tsyFa,- ,,ns .'yr: L. • 3 23 FLOOR STOP: IVES 442B26DXMS US26D s i ,1 -- a 1 r c c f I { . ,* F Y x x, - �� 5 24 IVES RUBBER DOOR SILENCERS, PRODUCT NO. SR64 4 5:: - .,. .. �� `` 1�. " -'. .._ � .' �..". .. .. .tf .... ,. e!. F. .T ., • 3.. .. „F .. - ..r.. .r. .. ...,. ' .:..L ...?..:.. -.. . -,. K .. . ... 1 DOOR SCHEDULE DOOR # DWG #� ROOM ,iNING (NOM.) DR/FRAME .ASSEMBLY HRDW GROUP DOOR TYPE DOOR CONSTR. DOOR SWING FRAME THROAT DETAILS NAME WIDTH HEIGHT STATUS RATING CONSTR. DIM. (IN.) HEAD JAMB COMMENTS 201E4 1A10 SECURED STORAGE 3' -O" 7' -O" NEW NONE 1 SND1 RH SND1 7 -1/8" - 1/A353 STC-53, 1. 202E4 1A10 LOBY 3' -O" 7' -0" NEW NONE 2 SND1 RHRB SND1 7 -1 /8" -- 1/A353 STC-53, 1. 201C3 1A10 AIL 6' -0" 7' -0" NEW NONE 3 SND2 LH & RH SND2 7 -1/8" - 1/A353 STC -53, 1, 4, 214C4 1A10 T ` ADL2 3'-0" 7' -0" NEW 20 MIN 2 SND1 RHRB SND1 7.1/8" - 1/A353 STC -53, 1. 203E4 1AI0 - LOBY 3' -0" 7' -0 NEW 20 MIN 4 C HMI LHRB HMI 7 -1/8" - - - ZO1B2 1A10 MOD AIL 3' -0" 7' -0" EXISTING NONE NONE A HMI RH HM1 5 -1/4" -- -- 2 210E4 1A10 CORRIDOR 3' -0" 7 -0" EXISTING 20 MIN 6 A HM1 RHRB HM1 --- - - - GENERAL A. PROVIDE ALL HOLLOW @EACH _ FRAMES _ 1 - ._ -- - .-- _ �L -. -__ __� SIDE HIGH DOOR NUMBER SIGN FOR EVERY METAL SWING DOORS TD bt FACTORY SHOP MOUNT f L _ W /DBL STICK TAPE _J___ CENTERED _ _l.. ON EXTERIOR .._ FRAME ' DOOR LISTED IN SCHEDULE. HEAD. PRIMED. ALL H.M. AND DOORS TO HAVE DOOR NUMBER STAMPED IN TOP HINGE CUT-OUT. � I I I i DOOR TYPES A Lip B C L i___ L. LUSH !PAIR OF S WING DOOR L t 1 . L _. .._._ --- L FLUSH SWING DOORS L� { i ( PANEL W /FIRE RATED GLAZING !FLUSH VISION RAMS CO_NSTRUCTIO_N ;GRADE E IKRIEG ER l rc - .. ' oF ?KRIEG . F .. - - - -- SWING DOOR W/6" X27" LITE OORIF_ H MI SN01 _- ._.- SND2 �.___. _ 2, 18 GA H.M. D0OR, 16 GA. L,. __.. � �_- H.M. ._ FRAME, I L r Y B071 SHOP PRIMED E ... .._... .._... .. -- - .__._._.. ,..__- I ' - _____ --- - ._.-_ _ t ` I 1_._OF ORDERED 1 I COMMENTS 1 2 3 W �'INSTALL 4 5 • IOPENING IS NOT FIRE RATED. DOOR 1-- USED AT AT - OTHER ANOTHER _- ......_._ ANO.R. . - ---- WITH FIRE RATING IN CASE IT IS REUSED LOCOCATION.__ ..1_.._.._ . ( _.� ___._ .j_ ___ _ _ . I _ ..._ _.._._ ..___...__ L - � INSTALL NOT AN EXIT ( SIGN AT BOTH "NOT AN EXIT' SIGN AT PUSH INSTALL NOT AN EXIT' SIGN AT PULL INSTALL POOR ALARM UNIT AT PUSH SIDES OF DOOR SIDE OF DOOR t-- - -_ - i _- - - - , SIDE OF DOOR. SIDE OF DOOR. ! 1 EXISTING STEEL COLUMN. INSTALL FIRST LAYER OF 5/8" GYPSUM WALL BOARD WITH SCREWS NO LONGER THAN 7/8." INSTALL SECOND LAYER OF 5/8" - GYPSUM WALLBOARD WITH SCREWS NO LONGER THAN 1 -5/8 ". USING SCREWS WITH LONGER THAN SPECIFIED WILL "SHORT" OUT THE SOUND ATTENUATION GAINS FROM THE RESILIENT CHANNELS. SECOND LAYER MUST BE APPLIED 90' TO FIRST LAYER WITH MINUMUM 6" JOINT STAGGER. NO GAPS ALLOWED. NEW STC 49 WALL. - COLD v \ E3 DETAIL SCALE: 1/2"= 1' -0" EXISTING STEEL COLUMN. INSTALL FIRST LAYER OF 5/8" GYPSUM WALL BOARD WITH SCREWS NO LONGER THAN 7/8." INSTALL SECOND LAYER OF 5/8" - GYPSUM WALLBOARD WITH SCREWS NO LONGER THAN 1-5/8". USING SCREWS WITH LONGER THAN P IFI WILL S EC ED LL "SHORT" OUT THE SOUND ATTENUATION GAINS FROM THE RESILIENT CHANNELS. SECOND LAYER MUST BE APPLIED 90° TO FIRST LAYER WITH MINUMUM 6" JOINT STAGGER. NO GAPS ALLOWED. NEW STC 49 WALL. SOUND SCALE: 6 "= 1' REVISION AWACS 40/45 ADL2 J #170567 -00 AWACS 40/45 ADL2 REVISION J #170567 -00 tU tlillil1 COLD v \ C3 & D3 DETAIL SCALE: 1/2"= 1' -0" 7 1/8" OOP JAVB - !!!11!x!4!11 t ili11i Miiili111 IN sTc 49 WALL BY LMC LMC 1 „ J GAP BETWEEN COLUMN FACE AND NEV CONSTRUCTION TO ALLOW FOR EXISTING 1 2A10 (2 2A1 Q A353 -20 GA 4" METAL TRACK SEE SHEET A354 FOR FINISH. 20 GA 4" METAL TRACK SEE SHEET A354 FOR FINISH. NEW DOUBLE LAYER 5/8" GYPSUM WALLBOARD, STAGGER PANEL JOINTS NEW RESILIENT CHANNELS 24" O.C. NEW 4" 20 GA. METAL STUDS NEW DOUBLE LAYER 5/8" GYPSUM WALLBOARD, STAGGER PANEL JOINTS NEW 3 1/2" GLASS FIBER BATT SOUND INSULATION FRICTION FIT IN STUD SPACE, FULL HEIGHT. NEW DOUBLE 4" 16 GA FULL HEIGHT JAMB STUDS SCREW TOGETHER 12" OC VERT SET GYPSUM WALLBOARD IN BED OF CAULKING - TYPICAL NEW GROUT FILLED SOUND DOOR FRAME 2" CLIP FOR HARDWARE MOUNTING. MOUNT NO HARDWARE INTO FRAME SOUND SEAL. CLIPS BY DOOR MANUFACTURER. APPROVED DATE 02.01.08 02.22 -08 SYM 4" 20 GA METAL FULL HEIGHT STUDS. DO NOT ATTACH STUDS TO COLUMN. -2" X 2" X 48" STAINLESS STEEL CORNER GUARD. (ALL FOUR CORNERS) 18 GA. RESILIENT CHANNEL 24" O.0 EW STC 49 WALL. 3 1/2" GLASS FIBER SOUND INSULATION BATT FRICTION FIT BETWEEN STUD FULL HEIGHT. 4" 20 GA METAL FULL HEIGHT STUDS. DO NOT ATTACH STUDS TO COLUMN. - 2" X 2" X 48" STAINLESS STEEL CORNER GUARD. (ALL FOUR CORNERS) 18 GA. RESILIENT CHANNEL 24" 0.0. XISTING DEMOUNTABLE PARTITION WALL. 1" 1 GAP BETWEEN COLUMN FACE AND NEW CONSTRUCTION TO ALLOW FOR EXISTING PIPES 3 1/2" GLASS FIBER SOUND INSULATION BATT FRICTION FIT BETWEEN STUD WIDTH, FULL HEIGHT. 1 35 REVISION BY DI DOR - YPES SCALE: 1 /4 " =1' -0" APPROVED DATE A B BOE /N 7} 6" X 27" VISION LIGHT PANEL W /FIRE RATED GLAZING ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN L.CLARK CHECKED T. HANSON ENGINEER T. HANSON CHECKED T. HANSON APPROVED APPROVED DATE 02.01.08 SUBTITLE TITLE ARCHITECTURAL MASTER DOOR SCHEDULE & DETAILS AWACS 40/45 ADL2 BUILDING 13 -03.2 COL. A -F /1 -7 GENERAL NOTES: 1. VERIFY ALL DIMENSIONS AND FIELD CONDITIONS BEFORE ORDERING MATERIAL AND COMMENCING WORK. 2. COORDINATE WORK WITH ALL REQUIRED TRADES. 3. REMOVE ALL DEMOLITION MATERIAL FROM BOEING PROPERTY UNLESS OTHERWISE NOTED. 4. LEAVE WORK AREA CLEAN AND UNCLUTTERED AT THE END OF EACH DAY. 5. REMOVE ALL CONSTRUCTION MATERIALS AND CLEAN ALL WORK AREAS AT THE COMPLETION OF THE PROJECT. 6. NO CHANGES SHALL BE MADE TO THE DRAWINGS WITHOUT WRITTEN APPROVAL BY THE FACILITIES ENGINEER RESPONSIBLE FOR THAT PORTION OF THE WORK. THE GENERAL CONTRACTOR IS TO VERIFY ALL EXISTING CONDITIONS. IF ANY DISCREPANCIES EXIST BETWEEN THE PROPOSED AND EXISTING CONDITIONS OTHER THAN THAT INDICATED ON THE DRAWINGS, THE GENERAL CONTRACTOR SHALL NOT PROCEED WITH THAT WORK UNTIL A CORRECTIVE PROCEDURE HAS BEEN IDENTIFIED AND APPROVED BY THE BOEING CONSTRUCTION MANAGER. 7. DOOR OPENINGS ARE 6" FROM ADJACENT WALL, UNLESS DIMENSIONED OTHERWISE. 8. DOOR MARKS ARE ASSIGNED RELATIVE TO THE MAJOR BUILDING -GRID BAY IN WHICH THE ELEMENT OCCURS. THE DOOR MARK IS COMPOSED AS FOLLOWS: M12N16 FLOOR NUMBER )GRID NUMBER SEQUENCE NUMBER GRID LETTER 9. DOOR FRAMES HUNG WITH LABELED DOORS SHALL ALSO BE LABELED WITH THE SAME RATING. 10. DOOR /ROOM NUMBERS TO BE PROVIDED BY BOEING. INSTALL NUMBER SIGNAGE CENTERED ON EXTERIOR FRAME HEAD ON BOTH SIDES OF DOOR & AT ALL DOOR LOCATIONS. MOUNT W /DBL STICK TAPE. 11. ROOMS ARE GIVEN THE SAME MARK AS THE DOOR INTO THE ROOM; FOR ROOMS WITH SEVERAL DOORS, THE LOWEST NUMBERED DOOR MARK IS USED. 12. OPENING FORCE OF DOORS WITHIN AN ACCESSIBLE ROUTE OF TRAVEL SHALL NOT EXCEED 5 POUNDS AT INTERIOR DOORS. ALL INTERIOR DOORS L SHALL HAVE LEVER HANDLES WHICH PERMIT OPERATION BY WRIST OR ARM PRESSURE. 13. DOORS: 3' -0" X 7'-0" X 1 3/4" 18 GA. HOLLOW METAL, FACTORY PRIMED FOR PAINT. S R OVED 01 A 9 20 \ COI 11.110.11a WILDII4G ,510 DEV. CENTER, WA CURRENT REVISION J#170567 -00 SHEET A353 JOB NO. DWG NO. SYMBOL 170567 -00 13 -03 -A353 RECEIVED JUN 052 PERMIT CENTER DATE COMP NO. 02.22.08 MILL/ 05.18.99/ 10:18 AM AWACS 40/45 ADL2 REVISION AWACS 40/45 ADL2— REVISION STAI R NO.1 J #170567 -00 J #170567 --00 BY LMC LMC APPROVED MOD AIL 201A2 DATE 02.01.08 02.22.08 SYM (218A4) 233A4) K232B5 ELEVATOR LOBBY 228B5 REVISION `202B2 CORRIDOR — RTSS 212C3 211B3 229B4 VENDING COFFEE 226C5 RECYCLE 227C5 231 B BY 7 0 0 0 0 APPROVED (23005) MEN, 225C5 DATE rziELIF‘r JANITOR 224C5 WOMEN 223C5 C a AL: OFFICE SPACE IBC 2006 B OCCUPANCY— OFFICE 4914 S.F., 50 OCCUPANTS AT 100 S.F PER OCCUPANT PER TABLE 1004.1.1 BOE /NGm AIL 202D1 ADIL2: OFFICE SPACE IBC 2006 B OCCUPANCY— OFFICE 2133 S.F., 22 OCCUPANTS AT 100 S.F PER OCCUPANT PER TABLE 1004.1.1 I2 w LL.1 DATA COMMUNICATION TEST DATA CONTROL 220D6 221D5 ADL2 214C4 (201E4 SERVICE COUNTER 219D5 % i /. tfr r y , • 11 cz)c i EC. STOR V 121) lr fri- ./ /__, / / � / /l (224E5) JTIDS 218E5 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE 0207E3 220E4 0 f O U U) w 223E6) DRAWN L.CLARK CHECKED T. HANSON ENGINEER T. HANSON CHECKED T. HANSON APPROVED APPROVED 215E5 I� ,j(222E5) OFFICE MEETING ROOM 217E6 OFFICE 216E5 DATE 02.01.08 CFA SUBTITLE TITLE STORAGE ARCHITECTURAL MASTER N0.2 STAI R NO.3 AWACS 40/45 ADL2 BUILDING 13 -03.2 COL. A— F/1 ---7 Y Y Y V" Y Y Y '" �I LEGEND: FIRE CAB. SECOND FLOOR PLAN- FLOOR & WALL FINISHES ( # # # X # ) XXX # #X# )=- GENERAL NOTES: RECESSED FIRE HOSE AND FIRE EXTINGUISHER CABINET (COMBINATION) NEW FULL HEIGHT STC 49 WALL. DOOR DESIGNATION. SEE DOOR SCHEDULE SHEET A353. ROOM DESIGNATION. ITEM SPECIFIC NOTE NOTE APPLIES TO ENTIRE ROOM. EXISTING CARPET TO REMAIN, SEE NOTE X. NEW CARPET, SEE NOTE X. 1. COORDINATE WORK WITH ALL TRADES REQUIRED TO COMPLETE THE WORK. 2. LEAVE WORK & STAGING AREAS CLEAN & UNCLUTTERED AT THE END OF EACH DAY & AT THE END OF THE JOB. 3. REMOVE ALL DEMOLISHED MATERIALS FROM BOEING PROPERTY. 4. REMOVE ALL TOOLS & MATERIALS FROM THE WORK AREA. 5. NO CHANGES SHALL BE MADE TO THE DRAWINGS WITHOUT WRITTEN APPROVAL BY THE FACILITIES ENGINEER RESPONSIBLE FOR THAT PORTION OF THE WORK. CONSTRUCTION NOTES: EXISTING FINISHES ON EXISTING DOOR & FRAME TO REMAIN. 11. NEW CARPET: LEE'S COLOR #438 "WINDSWEPT ", WALK OFF CARPET INSTALL APPROX. 110 SQUARE FEET OF 24" X 24" NEW LEES MODULAR CARPET TILES AS INDICATED BY HATCH. QUARTER TURN INSTALLATION. REFER TO LEGEND. EXISTING FINISHES ON WALL TO REMAIN. PAINT WALL COLOR ICI #1016 "WHITE ON WHITE" 1403 DULUX ULTRA EGGSHELL FINISH. PAINT WALL COLOR ICI #2006 "FROST" 1403 DULUX ULTRA EGGSHELL FINISH. ACCENT WALL PAINT COLOR ICI #533 "OBELISK" 1403 DULUX ULTRA EGGSHELL FINISH. PAINT DOOR FRAME & DOOR COLOR ICI "BLACK PEPPER" 4216 DEVFLEX HP SEMI — GLOSS. DEV. CENTER, WA A 6 \\___ cooe CCOUPNCt\ ________ OPIXOV CURRENT REVISION J#170567-00 SHEET A354 JOB NO. DWG NO. SYMBOL 170567 -00 13-- 03 —A354 RECEIVE] JUN 052 DATE COMP NO. 1 lip; PERMIT CENTER 8' 4' 0 4' 8' 16' SCALE: 1/8" —0" 02.22.08 8 FILL VOIDS BETWEEN LEGEND PARTITION FLUTES AT FIRE RATED P ES : - 1 V9o9og6 1 0 L O V09g 6c:60 8o/8z/zo :317 1.8u CERAMIC TILE PER WALLS AND SOUND FINISH SCHEDULE, INSULATED WALLS WITH BACKERBOARD AT TILE FIRE SAFING AS NOTED METAL DECK TYPICAL AT FLOOR LEVELS AND ROOF SEE STRUCTURAL 1A* U.L. DESIGN NO. CERAMIC TILE PER D916 (DECK ONLY) :777-7 _ '_ - -- ; :: I : ) �r_ (;�`- ,,�� 2 LAYERS 5/8" TYPE - c) ' X' GWB AT 2 -HOUR WALL AT STAIRWELL ENCLOSURE 4» METAL STUD _ ,� „ „ 5/8 TYPE X GWB ACOUSTICAL PARTITION "S" ADD _ 'T' - . -� � ;' _I -. �'J �� � ' -_ ` ' r ==4 r- ' „ „ » 5/8 TYPE X GWB » METAL STUD . AT ACOUSTICAL PARTITION S ADD : ;� - - - -�� .'l- ` 1 ,�'� -`-- _ _ _,�� '" \ __ -� , - ___�� : : FINISH SCHEDULE, PROVIDE CONTINUOUS GWB BACKERBOARD AT CLOSER AT FLUTES AT THE _- TOP OF ALL WALLS. STUFF _ I - -- -- INDICATES THERMAL INSULATION. REFER TO SPECIFICATIONS FOR TYPE OF INSULATION 'S' ACOUSTICAL TILE AREA ONLY VOIDS WITH INSULATION. FIRE SAFING .r BETWEEN DEFLECTION .; „ 5/8 TYPE X GWB OVERHEAD ATTACHMENT < +�4 * #��� w • '4 ` r ; ;;;;;;; ♦ * + + + ♦ + *� *� * * �� _; i o +.�.... , : . CHANNEL & STUD RUNNER PRE-- MANUFACTURED SECURE TO METAL DECK GENERAL INDICATES PARTITION. PARTITION TYPE, DEFINES CONFIGURATION AND STUD SIZE • 6 METAL STUD AT THERMAL _ PARTITION "T” ADD R --19 BATT INSULATION .:;.: -` � :AT ' -- "- ::::=1: - \ � -- �-� -�� ,`•``_ -_ -� _ -- _ � ' �. ' ' I: - ` - - �1 -� HOURLY RATING FOR FIRE RESISTIVE CONSTRUCTION NOTES: 3 1/2" ACOUSTICAL BATT INSULATION 3 1/2" ACOUSTICAL BATT INSULATION ACOUSTICAL INSULATION . WHERE CALLED FOR 1. ALL PARTITON STUDS OR FURRING STRIPS SHALL BE 1' -4" O.C., UNLESS OTHERWISE NOTED. __ _' __ 2. ALL METAL STUDS SHALL BE 20 GAUGE UNLESS OTHERWISE PARTITION DETAIL (PLAN) PARTITION DETAIL (PLAN) PARTITION DETAIL (PLAN) �' • NOTED. SEE PLANS. 3. ALL STUDS TO EXTEND TO UNDERSIDE OF STRUCTURE ABOVE, pIPIP" LATEX FIRE CAULKING (2) MIN UNLESS OTHERWISE NOTED. 3/4" FULL CURCUMFERENCE 4. ALL GYPSUM WALLBOARD TO BE TYPE 'X' UNLESS OTHERWISE (FIRE RATING PER PLANS) A (FIRE RATING PER PLANS B FIRE RATING PER PLANS) } (FIRE REFERENCE G.A. FILE NO. WP1076 FOR SOUND PARTITION ACHIEVE MINIMUM •, - - _ _ ' ' ' 45 STC FIELD TESTED - c2) LAYERS 5/8" TYPE gimimmi - BOTH SIDES NOTED. 5. ALL FIRE RATED PARTITONS SHALL COMPLY WITH THE "FIRE X GWB AT 2 -HOUR WALL AT STAIRWELL ENCLOSURE A 0 _ . - �. � I .111 eillill � �� r :• �� - PIPE- CONDUIT PENETRATIONS RESISTANCE DESIGN MANUAL" PUBLISHED BY THE GYPSUM ASSOCIATION (G.A.) AND /OR THE LOCAL GOVERNING BUILDING CODE. AT ACOUSTICAL PARTITION "5" +9'-0". 1 ( CONSTRUCTION PROCEDURES MUST SATISFY ALL REQUIREMENTS 6" METAL STUD . , 8" CMU CELLS GROUTED SOLID OR PERLITE INSULATING . FILL ADD FULL CAVITY Millil OF THE GOVERNING AUTHORITIES TO ACHIEVE THE FIRE RAT - SOUND INSULATION LNG INDICATED. 'J" r ~ - " � - "_ `, E BOXES, P N RA ION F T 6. ALL E ET T S OF FIRE RATED PARTITIONS SHALL BE �� X 5/8" TYPE "X" GWB AT ACOUSTICAL LATEX FIRE CAULKING (2) MIN PROTECTED BY EQUIVALENT FIRE RATED DAMPERS, LABELED » DOORS, FRAMES, HARDWARE, ETC. 3/4 FULL PERIMETER ALL SIDES 7. INSTALL VERTICAL CONTROL JOINTS AT VENEER PLASTER WALLS AT MAXIMUM 15' - O" O.C. METAL STUD W/ 5 - 8. INSTALL VERTICAL CONTROL JOINTS AT GYPSUM WALL BOARD TYPE X GWB AND 3 1/2" ACOUSTI BATT INSU LATION WALLS AT MAXIMUM 30' -0" 0.C. ,, . -' -- PARTITION "5" ADD 3 1 /2" ACOUSTICAL BATT INSULATION SWITCH BOXES, PANELS, ETC. PARTITION DETAIL PLAN E "vs? .F. = , `- .. . = . = = • r�0 -� ��� 9. ALL INLINE METAL STUDS PARTITIONS THAT ENCLOSE STRUCTURAL - PARTITION DETAIL (PLAN) DEMOUNTABLE PARTITION DETAIL (PLAN BRACING WILL REQUIRE SLOPED RUNNER TRACKS AND ANGLE CUT LATEX FIRE CAULKING (2) MIN STUDS. /4" FULL WIDTH &HEIGHT, BOTH SIDES 10. ALL RECESSED PANELS, HOSE CABINETS AND FIRE EXTINGUISHERS MOUNTED IN FIRE RATED WALLS. SEE DETAILS SHEET A504 RETAINER ANGLE FOR GWB WRAP BEHIND PANELS. 7 1/8" 18 GA. RESILIENT CHANNEL 24" O.C. (FIRE RATING PER PLANS) (FIRE RATING PER PLANS) \-____--- J --------Th �- -- - ----« 1 hi - 4 � I 1 INSTALL FIRST LAYER OF 5/8" GYPSUM WALL BOARD WITH SCREWS NO LONGER THAN 7/8." CERAMIC TILE 'ER • , CERAMIC TILE PER INSTALL SECOND LAYER OF 5/8" GYPSUM WALLBOARD _ FINISH SCHEDULE, BACKERBOARD AT TILE 6" METAL STUDS _ r ► FINISH SCHEDULE 11. PROVIDE BACKING PLATE AND EXTRA BRACING FOR ALL SURFACE MOUNTED TOILET ACCESSORIES, TOILET PARTITIONS, URINAL PARTITIONS, IIIIInIlmmmnn1111nIImmninsimnmmn DUCT BACKERBOARD AT TILE ~� ". DUCT PENETRATIONS WITH SCREWS NO LONGER THAN 1 -5 8 USING / SCREWS WITH LONGER THAN SPECIFIED WILL "SHORT" OUT THE SOUND ATTENUATION GAINS FROM THE RESILIENT CHANNELS. SECOND LAYER MUST BE APPLIED~ 90° TO FIRST LAYER WITH MINUMUM 6" JOINT STAGGER. NO GAPS ALLOWED. \2O GA 4" METAL STUDS 3 1/2" GLASS FIBER SOUND INSULATION BATT FRICTION FIT BETWEEN STUD WIDTH, FULL HEIGHT. DUCT LINER WHERE GRAB BARS, HANDRAILS AND DOOR HARDWARE. INDICATED ON MECH 6" METAL STUDS 12. AT ALL FIRE RATED WALLS RECEIVING CERAMIC TILE, PUT BACKER - DRAWINGS r 1 1 -LAYER 5/8" TYPE "X" GWB EACH SIDE • 1 -LAYER 5/8" TYPE "X" GWB BASE RUNNER EACH SIDE TRACK �R -19 THERMAL FLOOR ATTACHMENT BOARD OVER GWB. 13. RUN INSULATED GYPSUM WALLS WALL B UNL ESOARD S 4" ABOVE OTHERWISE FINISH . CEILING LINE ONLY AT ALL NON -RATED PERMANENT PARTITIONS EXCEPT FOR ACOUSTICAL_ NOTED LATEX FIRE CAULKING (2) MIN 3 f 4" CONTINUOUS -� FULL 14. ALL THERMAL INSULATION IS REQUIRED TO HAVE R -VALUE = 19 UNLESS OTHERWISE NOTED. SOUND INSULATION FULL STUD WIDTH ONE SIDE BATT INSULATION DEPTH OF GWB BOTH SIDES 15. ALL ACOUSTICAL INSULATION SHALL BE 3 1/2" THICK SOUND BATT N *REFERENCE G.A. FILE NO. WP1470 FOR SOUND PARTITION ACHIEVE MINIMUM 49 STC FIELD FIRE RATED TESTED PARTITION DETAIL (PLAN) PARTITION DETAIL (PLAN) , I A\19 D AC O U STI CAL �� ETAI LS (PE �1 ETRATI INSULATION. 16. REFER TO SHEET A200 FOR FLOOR TO WALL DETAILING. COORDINATE S WALL TYPES FOR ALL 1/8" SCALE PLANS WITH TYPICAL DETAILS. APPLY MIN. 3/4" LATEX FIRE CAULKING AROUND ALL PENETRATIONS AS LAYERS OF (FIRE RATING PER PLANS) ' (FIRE RATING PER PLANS) WALL GYPSUM ARE INSTALLED. NO GAPS AT PENETRATIONS ALLOWED. SEE DETAIL 2/501. SCALE: 3 ---0 FULL HEIGHT PARTITION DETAIL (PLAN) NOTE: ALL CAULKING AT (1) HOUR A501 17 . TYPICALLY TYPE G -WALL, BASE LAYER SHALL BE FIRE TAPED / CAULKED / SEALED BEFORE SECOND LAYER IS APPLIED. SECOND FIRE RATED WALL TO BE OF CAULKING W/ U.L. LAYER MUST BE APPLIED 90° TO FIRST LAYER WITH MINUMUM 6" RATED WALL USE ACOUSTICAL CAULKING. (FIRE RATING PER PLANS) . FIRE RATING. AT SOUND - - CERAMIC TILE PER 2) r� 'ER 8' ''E c2) LA YERS 5/8" TYPE FINISH SCHEDULE, 'X' „ 6 8 ., JOINT STAGGER. NO GAPS 6 1 .2 - ALLOWED. ,� __ , , - - - `r _ -_ -.:: �; ', - - -�' . :: : : : • . ;: I I i I I i I I I I GWB AT 2 -HOUR BACKERBOARD AT » X GWB AT 2 -HQUR WALL OF ELEVATOR SHAFT 1 GY PSUM - - ^ -__�,� ; r __�., ' .ry -- ,�__ -�,; -� .� -- - - - - -_. � : III _. : : :_ .~� :. WALL OF ELEVATOR SHAFT I 11 (II • : / r � _ - - .� ` , � : . = = TILE AREA ONLY CORRIDOR SIDE OF WALL 5/8" TYPE "X" GWB 2- LAYERS BOTH SIDES EXISTING (1 }LAYERS 5/8" 6” UD TYPE "X" GWB --------2-- DO NOT DISTURB AT THERMAL PARTITION "T" ADD R -19 THERMAL BATT INSULATION •- _.-------•\ �� ........ I 116" I I NEW HORIZ. RESILIENT CHANNEL � @ 16" OC �� \ y -- _.-/ � __- - --,� (2)LAYERS 5/8" TYPE "X" GWB EACH SIDE STAGGER ALL PANEL EDGES �� SHAFT LINER 5/8" �� 5/8 PE X GWB " " " i I { 1" GYPSUM SHA LINER „ „ 5/8 TYPE X GWB _ _ ' __��� LAY (2 )LAYERS P „ » 5/8" TYPE X GWB EACH SIDE STAGGER GGER ALL PANEL EDGES „ 4 18 GA METAL STUDS OC (OR EXISTING) * ct SOUND INSULATION fi ' �` �, -�- ..` � - -`` ~' 1 _� - - ` , - - - - - 4CH STUD AT 24" O.C. AT ACOUSTICAL PARTITION "S" ADD 3 1/2 ACOUSTICAL 1/2" BATT INSULATION " �, -_ -- � -------- `'�- - --- -' ` r — ~ ~ ' ,� ' —�' - - -_- :: � =III : - ! I I I I III { II �— „ „ „ 6 "CH" STUD AT 24" O.C. AT ACOUSTICAL PARTITION ADD „ S » - -- "� ` J ; - � --' , — - , � 4 18 GA METAL STUDS » (� 16 OC 3 1 / 2 " ACOUS TICAL GATT INSULATION _ -- ; � -��� - ~� SOUND INSULATION FULL STUD WIDTH FULL STUD WIDT ANC' �Q N DETAIL PLAN � PARTITI V 0 DETA (PLAN PARTITION DETAIL (PLAN) PARTITION DETAIL (PLAN) PARTITION DETAIL (PLAN) 1 PARTITION DETAIL (PLAN) (FIRE RATING PER PLANS) 0 (FIRE RATING PER PLANS) (FIRE RATING PER PLANS) (FIRE RATING PER PLANS) FIRE RATING PER PLANS �`�a ( PLANS) • ®��� c� I �TER1 R WALL TYPES \ / P RECEIVED RECD JUN 0 5 20Q13 PERMIT CENTER , ,.:' SCALE NO SCALE T ' 16\31:v.- � ' A501 f FACILITY DESIGN SUP PORT REVISION BY APPROVED DATE SYM REVISION APPROVED DATE ® �� 7 � •� i' FACILITIES DEPARTMENT A CCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN BY L.REYNOLDS DATE SUBTITLE WALL TYPES LAST REVISION SYMBOL E DATE 02 .08 ISSUE FOR CONSTRUCTION AEW &C SECURE ROOM J 5563963 -00 # SCC MHW WEM TWH 03.14.96 08.26.05 CHECK B SHEET A501 APPROVED BY DE PT . DATE ENGR. L.RE YNOLDS of 9 n CAT TEAM ACCOM J 557151 -00 � TWH 9 .9.05 CHEC o� B U I L � I � G 13 -� � 3 AWACS 40/45 ADL2 J #170567 -00 LMC 02.01.08 , � � W.E.MOQR HW COL M.F.C. JOB NO. J #170567 - 00 DWG NO. 13- 03 --A501 COMP NO. AWACS 40/45 ADL2- REVISION J 170567 -00 / LMC 02.22.08 APPRO K.RA ALD 02 96 SYM REVISION BY APPROVED DATE NW REVISION BY APPROVED DATE A ISSUE FOR CONSTRUCTION MC DK SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A ISSUE FOR CONSTRUCTION MC DK CL 03.14.96 B INSTALL CHILLER FOR AIL LAB J #791273 -00 HARRAH 06.17.99 C INSTALL POT FEEDER J #312215 -00 HARRAH 11.05.01 - D ADL -2 LAB J#170567-00 M.WONG RWS 03.14.08 . R, 1ST FLOOR `. CEILING SPACE — 2ND FLR UNDER RAISED FLOOR SEE DWG. 2M60 CHV 4 / BOP @10' -0 "AFF 1 �i i i ii iiwi y =r w.'.1► ii �t i7� n VI SIDE NW' 'i AWL r� Mr OR PIPING ROUTINC CHWS CHWS RN l e SA ` SEE P &ID DWG M36 0 irAN tij_ft r CH PLENUM ■1 COIL SE DIFFUSER SEKION FILTER SECTION MIXING BOX 2Y "CLWS & CLWR CH. PLENUM COI! SECTION SER SECTION FILTER SECTION MIXING BOX nit L L T Q�BOE /NG c' BOP © 13' -6" AFF 1 �J t a 7.0 4„ SCH. 4b W PIPE � SLEEVE W /ELASTO ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. vJ 2 DATE DRAWN J.MONRO CHECKED D.KLOTZ ENGINEER J.MONRO CHECKED G.SMITH APPROVED C.LYNCH APPROVED K.RAMBALDINI DATE 2.12.96 ISOLATION N SUCTION PUMPS 1M601M511 LEX CONN IN RISER (TYP) PIPE SUPPORT STAND (TYP) LEGEND: 1. SEE SHEET M1a, M1b, AND M1c FOR MECHANICAL LEGENDS AND ABBREVIATIONS. GENERAL NOTES: FOR COIL CONNECTION PIPING SEE DETAIL SUBTITLE FIRST FLOOR PIPING PLAN TITLE MECHANICAL MASTER BUILDING 13 -03 COLA —H /7 -7 DEV. CENTER, WA FOR CONTINUATION, SEE SHEET M452. 2 1/2" CHWS & R TO LCS HEAT EXCHANGER. 3/4" CHWS & R TO FC77 HEAT EXCHANGER. 3/4" CHWS & R TO WAVE GUIDE ANTENNA DUMMY LOAD. 6. FOR COOLING WATER SYSTEM P &ID, SEE SHT.M360. 7. SEE PLUMBING PLAN, SHT. 1M110 AND P &ID, SHEET M360, FOR PW FILL AND MAKEUP WATER SUPPLY TO CHILLED WATER SYSTEM. CONSTRUCTION N RETURN REDLINED PRINT BACK TO ENGINEERING WITH ANY DEVIATIONS FROM THE DESIGN. MOON WONG, 206-- 947 -4897, M/C 46 -87 FABRICATE AND INSTALL 2Y" COOLING WATER SUPPLY AND RETURN FROM THE INDOOR LIEBERT A/C UNIT TO THE OUTDOOR LIEBERT DRYCOOLER. USE TYPE —L COPPER AND ALL INDOOR INCLUDING THE TRENCH PIPING SHALL BE INSULATED WITH 1" THICK GLASS FIBER INSULATION. PROVIDE Y2" COLD WATER TO THE LIEBERT AIR CONDITIONER'S HUMIDIFIER. USE TYPE —L COPPER TUBING AND %" THICK ARMAFLEX INSULATION. SEE DWGS. M450 & 2M60 FOR THE PIPING CON'T. 3. INSTALL PIPING LABELS ON ALL PIPING. CURRENT REVISION J#1 70567 -00 SHEET JOB NO. DWG NO. SCALE: 1/8"= SYMBOL 1M60 OTES: If 13- 03 -1M60 DATE RECEIVED JUN 052008 PERMIT CENTEF COMP NO. 03.14.08 CONSTRUCTION NOTES: RETURN REDLINED DRAWING SHOWING ANY DEVIATION FROM ORIGINAL DESIGN TO ENGINEERING: MOON WONG, 947 -4897, M/C 46 -87 REMOVE TWO DRY COOLERS AND ASSOCIATED PIPING. THE REFRIGERANT IN THE SYSTEMS HAVE BEEN REMOVED. SEE ELECTRICAL DESIGN FOR THE REMOVAL AND MODIFICATION OF THE POWER. ISSUE FOR CONSTRUCTION INSTALL CHILLER FOR AIL LAB INSTALL POT FEEDER ADL -2 LAB REVISION BY MC ID J #791273 -00 HARRAH J #312215 -00 HARRAH J #170567 -00 M.WONG APPROVED DATE 03.14.96 06.17.99 11.05.01 03.14.08 DISCH. PLENUM COIL SE DIFFUSER 5 FAN SEC 1M60 M511 co UNIT, CH. PLENUM 0 SECTION rin a SECTION SYM REVISION APPROVED BOPC©10' -0 "AFF SCH. 46 PIPE j Z--- 1M60 M511 p irz,Aw® BOP © 13' -6" AFF u ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DRAWN J.MONRO CHECKED D. KLOTZ ENGINEER J.MONRO CHECKED G.SMITH APPROVED C.LYNCH APPROVED K.RAMBALDINI 2.12.96 ISOLATION ON SUCTION PUMPS SUBTITLE MECHANICAL MASTER BUILDING 13 -03 FIRST FLOOR PIPING PLAN LEGEND: 1. SEE SHEET M1a, M1b, AND M1c FOR MECHANICAL LEGENDS AND ABBREVIATIONS. GENERAL NOTES: FOR COIL CONNECTION PIPING SEE DETAIL 1M60 M507 COLA —H /1 -7 DEV. CENTER W FOR CONTINUATION, SEE SHEET M452. 2 1/2" CHWS & R TO LCS HEAT EXCHANGER. 3/4" CHWS & R TO FC77 HEAT EXCHANGER. 3/4" CHWS & R TO WAVE GUIDE ANTENNA DUMMY LOAD. 6. FOR COOLING WATER SYSTEM P &ID, SEE SHT.M360. 7. SEE PLUMBING PLAN, SHT. 1M110 AND P &ID, SHEET M360, FOR PW FILL AND MAKEUP WATER SUPPLY TO CHILLED WATER SYSTEM. CURRENT REVISION 4# 170567 -00 JOB NO. DWG NO. SCALE: 1/8"=1'-0' SYMBOL IM6OX 13-03-1M6OX COMP NO. RECEIVFr JUN 05 2008 PERMIT CENTFI 03.14.08 CONSTRUCTION NOTES: RETURN REDLINED PRINT BACK TO ENGINEERING WITH ANY DEVIATION FROM THE DESIGN. MOON WONG, 947 -4897, M/C 46/87 REMOVE 10X10 DUCTWORK SOUTH OF THIS FLAG AND REPLACE WITH 8"0 SPIRAL DUCT. INSTALL NEW 6"0 SPIRAL DUCT BRANCH OFF FROM THE NEWLY INSTALLED 8"0 DUCT WITH A VOLUME DAMPER. REMOVE AN EXISTING AIR SUPPLY DIFFUSER. PURCHASE & INSTALL TWO NEW TITUS 6 "X6" NECK MCD 4 -WAY AIR SUPPLY DIFFUSERS. INSTALL TWO 10X8 OPENING ON THE WALL FOR THE AIR TRANSFER. INSTALL TWO 24X18 OPENING ON THE WALL FOR THE AIR TRANSFER WITH SECURITY GRILLES. RELOCATE (2) T'STATS. 8. RELOCATE ALL EGGCRATE RETURN AIR GRILLES IN THE AREA TO THE LOCATION SHOWN. 9. FABRICATION AND INSTALLATION OF THE SHEET METAL DUCTWORK SHALL CONFORM TO THE SMACNA STANDARD. DUCTWORK SHALL BE INSULATED WITH FLEXIBLE GLASS FIBER 1.5 PCF DENSITY, K VALUE OF 0.24 AT 75 DEG. F W/ ALUMINUM FOIL FACING, 1%" THICK. 10. BALANCE AIR FLOW AS SHOWN ON DRAWING. 0., 170567 -00 SHEET JOB NO. 2M10 MFC- -95060 OL I 13- 03 -2M10 DATE COMP NO. 03.14.08 ISSUE FOR CONSTRUCTION GENERAL REVISION REVISION AIL HUMIDITY REQUIREMENTS RESTROOM HEAT IN 13-03 792353 -00 RESTROOM HEAT IN 13 -03 792353 -02 BY APPROVED MC DK MC DK HARRAH CH CH CL CL DATE SYM 3.14.96 8.12.96 8.18.99 4.12.00 REVISION BY APPROVED DATE F INSTALL SECURITY RWS RWS 04.27.06 G ADL -2 IN 13 -03.2 170567 -00 M.WONG RWS 03.14.08 Z;LAsivestEziva7® ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN M. CAUNITIS CHECKED D. KLOTZ ENGINEER D. KLOTZ CHECKED G. SMITH APPROVED C. LYNCH APPROVED K. RAMBALDINI DATE SUBTITLE TITLE 12.12.96 (DISCIPLINE) MASTER 2ND FLOOR HVAC PLAN BUILDING 13 -03 COL. A -F/1 -7 SCALE: 1 /8 "= DEV. CENTER, WA DWG NO. SYM A C D E CD 1 CD w M- = MN Ell MEN IN Mirl 1 111 r 1 MI M I INN N — NMI NMI MN RIM MN MIN CD B2 MINN ■■�11■[i■■�■■/�1� IIII �il���� ©1 ■III NNW ILimierAPa . MI ■IAN :: Mi1■ 1`IIi1M■ t!iM■11■■ \OIN1# ■11■• 111112111111111 NMI ■11l■ __WI!1i■ LIE IMMO ■N 1111 ■N =11E FD CD w te' rrwwrw.�rrr�a�rrrr.rr� mimmporalsmumwooriumir _ _��— �...,.�..,..� - - 7 ...., __ - ■■■■■■■■■■■la■I: ■■■ ■■■■■■■I� ■: �■■■�I 111.1 ■■■■■111 - 1 =MOM minilinffilli MMetilIMIll Irll ME 0571111111 1 nauliffi IIIMININIMMIKIIIIIIIM IIIBM m TR ti Nom =Now Nam 1 ■ 1 ramm 1 assuom , I.__ - BSI im ICI■ __�I ^ o me Nu 11 1 • mi-3 momr mommism MIMI Mani MI 1 1 NMI 11111111111111111111111ffilmmg MEE-MINIIIIIN In WIC NM El M 1 =UK ft wimammoilmisrm_u_Am ■ 11 maim wri ImmEI !ice // —rA N illi ■ MET11 =—� a INN - � ����� � ■�� ■ �■�,r _; e_N 1�! 120 �■■���■■■■■ I �_p MIN II EMI c � ��� ► ►1 � ■MI=EN_r�w_ � � S CREINED lPENIN+ E'S .. r � r'n� MIIIIIIIIIIMION ■� _����l I �:�_I (TYP _ PL) __ r M�\�_ M■ �»�� �;� •����� .CURRY ��• `��� ■n_ f K18 SE URITY —rfAI��._ ■EI�. x18 S E BiltaiMIIM=211111111=1 CUR ■ n _■ ���ri - ; 7 N 4/ SFD D5A CD 150 C 6�■11■ ���i ► 711 ■��►^ ►���ii« : c`�"'IMMII - - -- - H■ i- .■..I..I....�.. Ire - Il �iiiil ■i vT �' � ■ ■ i'711 � ■t��� �31 ENE ilkomilisainuniud LJ Jr�r.r.rrn.- W _ Wi `I li u i ■iEl \1I1Irt MEN =Sit It iivl�il�111112l ■1111111 1.111 -1 1i1=■�_�____ EMI ■ __�r`!Mrllil l ■11 ► 1; � N 24 / 4 i11MINA� II 1__ :.i �' 14 1 ,. . No r■ nom ___ ril�ilfl�' ■m.o �:- •■ o -:�1 - __ ■ ,I�,.�■r._ _., ■ A � �■■ r�����r' �rrl�■■■■ ■�■ ■■r�r�r�rrr�rrs�■�A■l�■�� ■a� ■A�� 111 8 NIA ���IIril1 =11 ■IN�1��! �i�� 34 8 immum_ rin um 10x8 OPENING mil x r -�-- -� - . ■ we r rrrr r a►w p ■���I�.' I��II fi■I■� Co ► 30 I r �� ( 12" BELOW TRUE '�'E'�� � r'125� ..�r� � � � � CEILING ■—r,�T.111wzakammtli �..,�� � �_1■mm�_���■ 1 \� C 11n i7�1� ■�r•�►, � "� .��� �"`' t . mot!" / 1 ■■ ?II��;��1�111 !�' 1 � ' G4 r�el5 0 V 1 __IMIE1i .. ,111ra7■1,�I���Ii ■.. ■NAMII�i� I =I lilllis�. l■ 11� ��M WAIM . r, PROMMI�[i�'l'STMVA M IMIL 6 0 �� .�.■E ; � 11 ■al 111111 IILMIIN! IMMIE` !�I WAIIIIM iERMIN�� , ' I1 I 1� e / imiN �I� ■■►\� ■■tiaiNE1 =M 6 1311 , =Mk 1E1E1�� or\igampt ► �.Ili�l�'�1 R ■ M \■ r� -- I MOW 11 : ,.. MII■nG... oi11T!! :� II �m'ri • P 4 `�IILr' • �►�� � �� i:t1�i■ �� .: ■NI�rL�► 0 ■1 ` ■sr�v r I ri I .r ■.� omil���■ IllniNEWEINNS.77111E ILI= /11111■WIlifi smaimmmEnamm Nommimillimmilartal ®� ��� ����- ��11l1i�=il�;� ma c.. .. �I■ ■� 7- r■�. -■■sC� --I .- - =■■ ■ . _ �■ 1 wrr+r.rr 11 r..1 1 � �- � R��.■ .r r� r�r�■ ■ rr ■i■r ■rrs� � .�.r� ■w■�rw - �r - � " T �_� ■� ■■rrfrrre 1 1 RG IMMO ..”1l� r•r,� a r- I ■_� i• aligar ��'""` 1l !rlVl_ I INa��i /II ►�11 __ ■Erman S �'►�` , GD 715 .. . mai 121 1 .1 -r I I! t n2 ■ - gimp -1 ■i g ia r : g �t'i`�!I�IA�!!►!Ikat , �_ . ''� `��IIILlegil i mic s rrrN■r■u � r�� *�r ■..��� t�w��u ■ err �►�� rr�� r �' "[:.7e � ■rrrr > ri � J l�r� . � .. r•L 11I � ri :....:r _.■�._ � ��rf 1 rrar_ 7aT T cyi'l_ =.1�� ���T ww r1�! , r r V► w" i IT/ rI �r�._� l� ±rr ■,w V I�� GJ w _ �11t� "�I� � ' ■�iltm■I EMI l�� S �.' �Mi1rl -F►- �_ Mk ��I�rT�Il:' % , 0 ��II1 ii' IlIFMMI ��i ��* 1111 i 12=2Mil IIMMIM ■�r" Ii, liP- .=■■ ` `J 1i►.ir 8 CF /r ': I p ■ ■I�IT.TIi ■ I/ II ' ■ I M.■.. ■' � ..1�1 �11 11�� ■ 1Mr /mil■ , ,�„ '\ r •- r ' I Ld I. Amu ■.. � �� id ! l w 411111 �r��r� 14 14 I "Ir R . ice IBS. IIII ITAIIIIII • III �: i �� v II El . 1 ,� N �� �� �i� ` � I�1���1�!�!Illr�rr■i� o -- I��1111�� ■r�1 CD � CD v AL vir + I'�'I�■i■■��r � '. III■ ■ �� I ��■II��i■�Il�����rr \ i . -- M. � il� �1iiiM■ 1 I 1 Q � mam� mill — 1- I j'i i m 16/20 UP H.�11li � -- •: ■■ 1I� BOD ��� '' ■I � II��+: iii 1 As% ter•.. v. .,, -� l - � (��Ir'= ' �.__.__ 1 I ' - •1�� ■ ■WHIE vim:- 10 , -. AFF � .11 �1r1 _. i - 11.1 l�i7 — - -. 1 .1'R■.■ ■■ = W . A■ IONI�■'dLIAI ►vi;i�� i �■ -_ __i�U ._III no— u �� G �U� 1 .L isima Lmwv4 _ � —�. ---. .r.�,r�l� . i -1 IIl i}n I � M �`` -� � �� rv��+ri:r.. a�rar,. .rru � � 2D6 r � -m .N!. i I-NI rdibI 1 �_ © L _ - -1�'wr ssro■��i�� ..�met.1atiu■I�i m�% _ e _ '.�_� I I Iaiit� ■U A , � r i' : I urrr■■■■■���wm I ■ I I ;; i -�� 1 u c ' I --. �il���f' l ■■ mem1IIIII o....I.I mum _ . l�+� rii �- w i iii r■■� (1[111 „_.. ICE i : r-_- _ r;_ . .T �Inr._ r,..: i. RG v RC Ala anik 360 CFM (TYP 4) 360 CFM (TYP 4) TO VV /1B5A SEE SHEET 1M10 3G0 CFM T (P 2 2M 10 M508 385 CFM F6A , %�. ��� EIMER 6A tom - a - ,, ai ail - mstaf /tri 250 CFM (TYP 2) 2-M-1-g SCALE: 1 /8' =1 ' -0" 1 1/4 "G UP TO AH3D7 'G DN SECCND FLOOR PLAN 411 Boa 10' -0 "AFF AIR MEASURING STATION S 0 AH3E7 AMS IN RISER, SEE SHEET M504 MAN BARS CS ZED UP TO AH3E7 VOLUME DAMPER, TYP 9'--8" BOTTOM OF DUCT TO VV /1F4B SEE SHEET 1M10 650 CFM 185 CFM 170 CFM 550 CFM SEE DETAIL SEE DETAIL SEE DETAIL 0 • 4 2M10 M505 2M10 M505 2M10 M505 J r` LEGEND: 1. SEE SHEET M1a, M1b, AND M1c FOR MECHANICAL LEGENDS AND ABBREVIATIONS. 35 KW DUCT HEATER FOR 28"0 DUCT. SCR CONTROLS TO USE 4 -20 mA SIGNAL OR 0 - 10 VOLT SIGNAL, 480V 30. Y" MESH 12 GAUGE (0.105" DIA.) HARDWARE CLOTH OVER END OF DUCT PENETRATION. PROVIDE. SLEAVE AS REQUIRED. INSTALL WITH TAMPER -PROOF CONSTRUCTION USING TAMPER -PROOF SCREWS OR RIVETS. GENERAL NOTES: 1. VAV TERMINAL UNIT INSTALLATION, SEE DETAIL 2. VAV UNIT ACCESS LABELING, SEE DETAIL 3. LAY -IN DIFFUSER INSTALLATION, SEE DETAIL 1M10 M503 ■ 4- �vN 1 0 00‘ lext- otl 8' 4' 0 4' 8' 16' All 1 M 10 M503 1M10 M503 RECEIVED JUN 0 5 2008 PERMIT CENTE}- CONSTRUCTION NOTES: RETURN REDLINED PRINT BACK TO ENGINEERING WITH ANY DEVIATIONS FROM THE DESIGN. MOON WONG, 206 - 947 -4897, M/C 46 -87 INSTALL INSULATED DUCT ACCESS DOOR ON BOTH SIDE OF THE WALL (TYPICAL OF 10). FABRICATE AND INSTALL SECURITY GRILLES IN THE DUCT AT THE WALL. SEE DETAIL 2 OF DRAWING M506. INSTALL PIPING LABELS ON ALL PIPING. SYM A ADL-2 LAB REVISION .■_■■ L _ A .I ■■IIjiiii L 1111■■■ ■■ i ■ im • • 111 1.. ■■ ■■■■■ ■ 1�.. ■ _ ■ ■11�`R ■■ ■ ■ ■I■■ ■ ■■■■■_ ■■■ ■ ■ ■■ ■PAIII i■■■■■■■ ■■ ■■■■■■ ■■ ■■■■11111■■ ■■■ ■ ■■■■ ■■■ ■ w■ ■ __■■■ ■■r_■ ■■ ■■I■■■ ■■ ■■ ■ __ ■■■■■ ■■ ■■ ■■■■■■ ■■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■■ __1111 ■ ■■■ ■■■ ■ ■■ ■■ ■__■■■■■ E ••••■1 ■ ■ •••••• ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■■■■■■■ ■1111■ ■1111 ■■ ■ ■ ■ ■■ ■x1111■ ■ ■11■ ■1111■■■■ ■ __1111 ■■11 ■■■■■■■ I11■S■■■■■■■ ■■■ ■ ■■■ ■ ■ ■ ■ ■■ ■ 11111111u ■ ■ ■■ ■1111■ 11111111■ ■ ■ ■ ■r111111111111111111111111111■1111111 ■ __ ■ ■ ■ ■■ ■ ■■■■■1111■ ■ ■■ ■■1111 ■ ■ ■ ■ ■ ■■ ■ I■■ 11■■■■■■ ■ ■■■11 ■■■■ ■ ■ ■■■■■ ■ ••••••••••••• ■ __■■■■ ■_ 1111■•■ I■■■■■■■■ ■■■■■■■■■■■■■■■■■■ ■■■■■ ■■■■■■11■■■■1111■■■■■■■■11■■■■■ ■■■ •■■I■■_ ■■■■■ i■■■■■■■■■■ ■■■■■■■■ ■■ ■■■ ■■■■■■■■■■■■■■■■■■ ■■111■■■■■■■■■■■■■ • ■■■■■ ■■■■■I■ ■••■■■■ ■••■■••••••■■■■••••■ ■■ ■•■■■••••■•• ■■■■■■■■■■■■■ ■ 111 111 11111 1111111111111111 ■ __■■■■ ■��■■■■■I■■■■■■■■ ••••••• ■__ ■ ■■ 1111_0 ■ ■■ ■■1■■■■■■■■ __ ■■■ ■■■ ■■11, :!."■■■■■■■ ■■ ■■■ ■■■■■■■■■■ mi■■■■■■■■■■■■■■ ■ __ ■■■■mili__1111■■■ I ■ ■■■■■■■__■■■ ■■■■■■► ; mm■■ 11■■■ ■■■■ ■■■■■■■■■■■■i•••••••••■ ■ ■•■ ■ __■11■■■ __■■■■■I■■■■■■■■ __■ ■r-, mina,: 11. 11■■■■■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■■■■■ ■m11■ ■ ■■ ■ ■ ■ ■ ■ ■ ■■■ ■ __ ■■■ ■■ _■■■■■l■•••■••• ■ 1111■■ 11■■ 11■■ 1■ E,•■•■ ■ ■ ■■ ■ ■■ ■ ■ ■■■ •■■■ ■ ■ •••••••■•••• • ■■■■■ ■■■■■I■■■■■■■■■■11 I■■■■■,:T■; ■■■ 111■■■ ■■ ■■ ■■■■■■■■■■■■ ■ ••••••••••••• ■ __■11■■■ ■■■■E11■■11 ■■ ■111111111M11 .. f11SMr".' Flil11r' i'■■ K1■■ ■■■■■■■■■■ ■■■■■ ■ ••••••••••••■• ■ __ ■11■■ ■_ ■ ■■■■■111 ■11. °'�� 1pp111�111!� i l i■ n 1111■■ 1■ 1111■ ■1 ■ ■ ■ ■■■■■■■■ ■■■■■■■■ ■■■■■■ 311 ■■ ■■■�r■1 mswi111�:°....:..2= 11 °;iu i ; ii L:tr IIn IIIMM■L■11I'7 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■■ 1■__■■ ■■■IIIIIIIIIIM111:J■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 11011M11111111111111 NM ■till •••\11:J ■ ■ ■ ■ ■ ■ ■ ■ ■ •••••1 1 ■ __ ■■■11■ ■■ ■ ■11■11■ ■■ ■■ ■_ 11■ ■In III InlnillIME11l11 ■11[x■ ■■■■■1111■■■■■■■■■ 1■ __ ■■ ■■■�� ■■■ ■■■■■■ ■■11■ __III ■`:.:1I ■III■ In ■1111■■■ ■►II■ ■■ ■ ■ ■ ■ ■11■■■■■■■ 1■ _- ■ ■■■■�� ■■ ■■■■■■■■■ ■ ■�■II ■ ■■` "�l1111111IIIIII �Inirj j ■ > ■■■■■■ ■■■■■■■■■■ IN smiliiiiiiiinlimilliiiim ['11■■■■■■■■■■■■■■■■ 1■ __ ■■ ■■■ •••11.111111•1I ■■■ ■1E1111 _ 311 ■■ ■1111■■■■■■■■■■■■■■■■ 1■__■■■■■ I■■■ __ I11�■■■■�111�11�a■■■�1■i 1■ I ■■■■■wM1111■■■■■■ ■■1.11■�■■ ■■■■■■■■■ ■■■■ III En= ■ ■ ■ ■ ■11■■■■l!`i ■e ■11■a■ ■I■ EMI I1MI ■IUIIIIP11 ■ ■ ■ ■■ ■■ ■1111■■ ■ ■ ■ ■ ■■ ; 1■__ ■■■■■rte ■ ■ ■■■■■11■■i =11111I■■■ ■1■ um lniitnr.idimaiu ■■■■■■■■■■■■■■■■■ mil __ ■■■■■rte ■ ■■ ■■■■■■■ 11■•__ ■II■■ ■■I■ 111 •11 HEE •In1111 •■ ■■■■■■■■ ■ ■ ■■■ ■ ■■ ■■ 1■ __ ••••■ ■ ■ ■ ■11 ■ ■■■111 ■ ■ ■111111■lI■■■ ■101 li■ ■1111n1■I11 ■10ilil ■ ■ ■ ■ ■ ■ ■ ■■ ■■■ ■■■■■■■■ 1■ ■■■■11111111111111■■■■■ ■■■■■, ■■■ IESI ■■■ ■INi Iii • II11I11■I n ■1111111U■■■■■■■■■■■■ ■■■■■ ■■ 1l __11 ■■■■mom ■■ ■11�■■■11■■■MIlI1111■■I I '�� InINI ■In■InII11■■ ■■■■■■■■■ ■ ■■■■■■■■ '� � �'•■ �■■�■■" "••�'� 1111 ■■ ■11111■ ■ ■ ■1■ ■.Ilia:= ss uint o n um n ■I III ■■■ ■■ ■ ■■■■■ ■■ ■■■I■ ■ ■■ �J PM W mama times CSI w ^ w -- ■E r ■ 112 i mom J #170567 --01 BY M.WONG APPROVED DATE 03.12.08 SYM D r REVISION BY 0 0 0 APPROVED DATE 220 C 220 IC7 UNDER RAISED FLOOR PLAN SCALE: 1/8 " =1' -0" g • ACC EPTAB I LIT( THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE II DRAWN M. WONG CHECKED ENGINEER CHECKED APPROVED APPROVED MIME NEM w 4TO DATE 01.24.08 SUBTITLE TITLE MECHANICAL MASTER • BUILDING 13 -03 COL. A —F/1 -7 UNDER RAISED FLOOR - 2ND FLOOR HVAC PLAN LEGEND: SECURITY GRILLES / MANBA SEE DETAIL 2 OF DWG, M506. EOUIPMENT NOTES: , _ -..- 0 0 . DEV. CENTER. WA \ • c roVit a . c CURRENT REVISION J #170567 - 01 SHEET JOB NO. DWG NO. SCALE: 1 SYMBOL 2M10A 8 " =1'— DATE 13- 03--2M 10A RECEIVED JUN 0 5 2008 PERMIT CENTER COMP NO. 03.12.08 16' co SYM A ADL -2 LAB E1ii.iiiujui.MIIII■ ■ ■ ■ ■ ■- ■■ ■ ■ ■1a1■ ■ ■ ■■ 11 =111 ■ ■ ■Ma1 1111■ ■ ■ ■■ ■■ ■ ■ ■ ■■I ■ ■� ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ l- IN ■ ■■1MELEME11■M■ 1 ■ ■11■■ ■ ■ ■ ■M ■ ■■■E ■1=11111111■ ■ ■■ ■11111111■ ■■■NE■■ ■IMMI■rE ■■■MINE■ 1■■■■■■ EM■■■ M■■ ■o■■■ ■■■ ■ ■ ■ ■ ■ ■ ■ ■ ■■ ■ ■■ ■■ ■ ■ ■1111■ ■■ ■1111 ■■ ■ ■11I ■11n ■■N11111■■■1111■ ■ ■ ■ ■■11■ 1■ M■■ M■■■■■ N■■■ N•1111■■ I■■ w ■ ■■ ■■M ■ ■■ ■11■■■■■■ ■ ■■■■■r■■■ ■11I ■1111■■■•■•M■ ■■■■■■■r■■N■1 1 ■11■■■ ■1111■■iu■■M __ ■■■■■■ ■ M■■■ EEI11E■■■■■■■■■■■■■ ■■■N■■•■■■ ■N■■NM■IMIllp ■11■N■ ■ ■1 Ii11i■ E■ 11N■■ i■■■ M� EN■ �E■ N■■ EM■■ i■■■ 11E ■ ■ ■Mi ■ ■ ■NN ■ ■ ■■��� ■NM ■ ■ ■1111r'��. -■-- ■11111 ■E ■1 1 ■iE■ 1111 ■NEi ■ ■Ei1�1 ■Ni ■ ■� ■ ■N11 ■iM ■11 ■ ■ ■ ■11 � �N■ Mii■■ 11■ MN■■ r, :�N ■ME ■11 ■11t,��:�ii ■ ■ ■rt ■ ■ ■ ■ ■ ■1 1■•11111i:#11i■■■ ■■MiWui■■M■ ■ ■ ■ ■ ■■■ ■■■■■■11 ■■■■■■■ rE■■■ Mii ■ ■E(iMEMIUM■ ■RU■II■■■ ■■1 1 ■i ■ ■1 I ■ ■i ■■■■ IMEMEI ERMINI ■■ ■■ ■ ■ ■■M■ MAIM■ ■ ■■■ ■ ■ ■■ ■ ■ ■11 ■ ■■i11iiiNETIONIM ■!L■�.w 'V ■■■ ■■1 1 ■M ■■ IN ■■M■■■■I■■I I11 ■1111IIE ■ ■IM■ ■■■ 1111■ ■ ■11■ 1111■ X11111■1■ ■ ■■■ IMMII111■ ■!I ■ ■ ■11■■■ ■ ■1 ■■111111 I■aI■■Nlrm JI 11■ li■ 11i�n niiiiiiiiiiei�iuii�i■ iiii ■iiilliiMr'■i■riiill�iiiiil�i i�iiiiiii■ i■ �iiiliiiiiii�iiii�Il�il�i�JiiM ■ ■ ■1 ■Ill ■ ■ii ■ ■ ■ ■ ■IL IM ■NN■: ■I��E ■ ■ ■ ■t ■�1 ■ ■11 ■ ■� ■ ■ ■ ■■ ■1111 ■e11 ■ ■■ 1111 ■ ■ ■ ■M ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■Ii� ■ ■11■■ ■11 ■ ■■ ■111 1■■■■ ■iUf11 ■ ■ ■ ■ ■ ■ ■_ ■ ■ ■ ■■ ■�■i■ ■ ■ ■ ■ ■ ■■ 1111■■ ■■11■N■■■■ ■ ■■ ■■■ ■M■ ■11■ ■11 ■Ei : r : ■ ■II ■1111■■ ■1111■1 IM■■ ■f il.;1 111 ■ ■ ■ ■ ■■ ■ Elm= ■■■ C■■■■ M■ E■■■■■■■ M ■ ■ ■ ■ ■M ■■■■■■■■11 ■ ■■_I.ell■iintlil■ ■1111 ■ ■■ ■ ■1 1N■11■iIIM GM■■■■■■ __■■M■■■ ■■■ N■■■■ ■11■N■■ ■■MM■■NNNM ■■■N■i■■M■■■r�l rararamai■M ■■ ■11i■1 1■■■■ ■ ■11o1■■■■■M■ __■ t ■E■■11111■■ ■1111■■■11O ■1111 ■■■■■MMr■■■ ■11.11■■ ■■ ■•■•••• ■ ■MN ■11■■ ■■■■MI IN ■11111■M■ 111 •■■■ ■■■1111■ ■■ ■■ ■r■■■M■E ■ ■■E■■1111■M INIMM EMSOM11 ■IN ■ ■ ■■N ■0 •011•■■ ■1111■ ■■ ■111 1■ N■ 11■■M llir: N' 1■■■■■ i■ ■N ■■ ■■■I■■■■■■■►.i11■limmiA■■ 1111 ■■■Mir■". ■:Ia. ■■■1 IEME ■N ■N11�11 ■N�1■ m 11■1N •E 11111■ ■1111■■ ■11■ ■■111111■�'111■■■■►� ■■■■ IMENI ■■■x'1111■11111111 ■■11■■ ■■■■■1 '] ■M■ ■a■111111111 11111r7M -- --- M EM ME ■I. MIN ■R" 1111111111 ■11■1N ■■ ■1111 ■�1[ '1 ■ ■ ■■ 11111111111111 ■1�; 111 ■■■■■EIC1N■ ■■11 ■ ■■11 ■� ■ ■��11 ■1.11 ■i11 ■ ■ ■■ �� ■ ■M ■ 11�>�1�'I,�ii ■ ■ ■: ■ ■I■ ■■1111 1■■MM■■■ 111■■■ ■■11■ fir■■■ ■�■■■1l11111■■■i■■ m i`■■■ ■eatr "gamm1111 ■ ■t■ ■111 1■ ■■■ ■••11111■E■M■■ ■E■■ II ■■1 IM■■■■i ■M■ iii ■ ■■■■■. :Ii ■iII■N■■►.i■■■■■i1111 1 ■11■■•IN 111 ■■1111■___ ■N ■N_NM■I11 ■ ■■i■1i■ ■i1 ■■111111■!111111i■■■i ■11■■■■■r■I11 1■■■ ■■ •st11■■■■■■■ ■■■■I ■M■m11 ■ ■■ ■Mir %■i■IM ■0■Il■IIIC 7■■MII■■■I■ ■■ 1 1 ■M 11111 11111 ■■■■ ■rte ■ ■ ■n emit.M ■ ■E■ mi ■■ ImIGw w-- -- ,.r.�..,■■■■MNi■■.,...! mmil.l 1■■a■iiaMt trim ■MN■__•■■■1m■ ■■oII■ ■■■ ■iaEefM111 i11iI��lEiblii ■i1i5r1�'i111ii1�11iiMi3 I11 ■11r1N:IN 1■I■■imarg ■■11I■ ■ ■ __�■11■ ■ ■■ ■■ 111" ■■m11aI11IauC 371 ■■■■ ■I�tN■ ■ ■ ■■ ■a■■1 1 1 ■■■■■■ ■111■■■■■ ■ ■ �� ■11 ■ ■ ■ ■ ■■It ■ ■ ■ ■ ■t l ■ ■ ■r■ 1111 ■li�(W11 ■ ■ ■ ■��� ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■�nrr IN■11■■11 ■111■■■■ ■■■1.1 _■■■■I _ ■■ ■111 ■11■■ 1111■■■ 11■ 1i11■iuI ■ •11:M1iiiia ■ ■ ■i ■ ■II11I 1 ■ ■ ■ ■■ ■11111 ■ ■ ■ ■ ■M ■� 1111■• ■■I ■ ■ ■Ia1 ■ ■ ■■ 111■■ VIII! 11!!! !l�1�1111 ■ ■ ■ ■ ■ ■/'� ■ ■ ■ ■ ■11 ■ ■ ■ ■ ■ ■■ ■Ill IM •11■■■E111■■■ ■ii■1111• I ■ M■■ 11■ 11■ ■1.11111011M:1111111_•MINI■■ ■ ■ ■ ■ ■ ■i ■111111∎ 111■ 1111 ■ 1�■ �11■■ ■M11E�r ■ ■ ■ ■ I � ■■ERII■E/1■'1 ■■■■LN 1111■ ■ ■■ ■►1 ■■ ■1111■1111■■ ■1111■ir°� - 1N■■ ■iM�l 1 ■ ■ ■ ■11 ■ ■� �■■111 ■•111111111■ ■■1111 ■■ IMEIIII ■MM■ ■1111■■■■■■■■ ■ ■M ■ ■ ■ ■1! , j= ••N ••••` REEF" -• mr- 1 ■�� ■ ■■■r■ IMITIEN ■ki► IINNNNN1111 ■E ■ ■iN •■ ■ ■ ■'■ ■•■ ■ •■ •■ •11 IIII r ! { i _ __ jV I II Li 1ST FLOOR ww 7:71141iii LJ REVISION J #170567 - 01 BY M.WONG SEE SHEET FOR DETAIL APPROVED RWS 452 DATE AN 03.14.08 SYM REVISION E ILI SECOND FLOOR PLA SCALE: 1 /8' =1'-0" BY v APPROVED DATE U BALAN SEE S FOR F C ALVE M361 ETPOINT • DRAWN J. MONRO CHECKED D.KLOTZ APPROVED C. LYNCH DATE • SUBTITLE • SECOND FLOOR PIPING PLAN OD- LEGEND: $ i totV • Ok i 1. SEE SHEET M1 a, M1 b, AND M1 c FOR MECHANICAL LEGENDS AND ABBREVIATIONS. GENERAL NOTES: FOR TYPICAL FC UNIT PIPING CONNECTIONS, SEE DETAIL A M260 FOR TYPICAL VAV TERMINAL UNIT PIPING, SEE DETAIL 75 2M60 M506 CONSTRUCTION NOTES: RETURN REDLINED PRINT BACK TO ENGINEERING WITH ANY DEVIATIONS FROM THE DESIGN. MOON WONG, 206- 947 -4897, M/C 46 -87 INSTALL 15 —TON LIEBERT DOWN FLOW A/C UNIT FOLLOWING ACCESSARY PURCHASED BY BOEING. THE UNIT INCLUDED 30" HEIGHT FLOOR STAND AND TWO LIQUID WATER • DETECTORS. FABRICATE AND INSTALL 2)" COOLING WATER SUPPLY AND RETURN FROM THE INDOOR LIEBERT A/C UNIT TO THE OUTDOOR LIEBERT DRYCOOLER. USE TYPE ---L COPPER AND ALL INDOOR INCLUDING THE TRENCH PIPING SHALL BE INSULATED WITH 1" THICK GLASS FIBER INSULATION. PROVIDE r" COLD WATER TO THE LIEBERT AIR CONDITIONER'S HUMIDIFIER. USE TYPE --L COPPER TUBING AND %a." THICK ARMAFLEX INSULATION. SEE DWGS. M450 & 1M60 FOR THE PIPING CON'T. 4. USE DOW CHEMICAL, PROPYLENE GLYCOL (DOWFROST) 30% BY VOLUME. THE SYSTEM CAPACITY IS APPROXIMATELY 107 GALLONS. 5. INSTALL PIPING LABELS ON ALL PIPING. CURRENT REVISION J#170567-01 SHEET JOB NO. M506 8 ' 4' SCALE: 1/8"=1'-0" SYMBOL 2M60 DCA -95060 0 4' 8' 13-- 03 -2M60 RECEIVED JUN 052008 'EHMIT CENTER DATE COMP NO. 03.14.08 16' p rzterzAw® ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE ENGINEER J. MONRO CHECKED G.SMITH APPROVED TITLE MECHANICAL MASTER BUILDING 13 -03 COL. A —H/1 -7 DEV. CENTER, WA DWG NO. SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A ISSUE FOR CONSTRUCTION MC OK CL 03.14.96 APPROVED C.LYNCH B ADD 4" SAN PER UGM110 MC DK CL 03.26.96 C HWC PIPING CHANGE MC OK CL 08.12.96 0 REPLACE HOT WATER HEATER 2023151 MAINT. 02.23.06 E ADL -2 LAB J #170567 -Q1 M.WONG RWS 03.14.08 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN DATE CHECKED D.KLOTZ _ APPROVED BY DEPT. DATE ENGINEER J.MONRO CHECKED G.SMITH APPROVED C.LYNCH APPROVED K.RAMBALDINI 02.12.96 ACCESS 1 ANEL; SEE ARCH IWGS "CW UP P 1 1 "HWC 1/2"TP CONSTRUCTION NOTES: RETURN REDLINED PRINT BACK TO ENGINEERING WITH ANY DEVIATIONS FROM THE DESIGN. MOON WONG, 206- 947 -4897, M/C 46 -87 PROVIDE Y2" COLD WATER TO THE LIEBERT AIR CONDITIONER'S HUMIDIFIER. USE TYPE -L COPPER TUBING AND 3 4" THICK ARMAFLEX INSULATION. SEE DWG. 1M60 FOR THE PIPING CON'T. P TO 3R TO 1ST FL P -3 3 /4 "ID IIIN TO 2 "SAN ABOVE T - RI (TYP P -3) OF P -4 P -3 3 "SAN 4"SA UP TO 3RD FLOOR & DN TO 1ST FLOOR V 4 "FC0 2 "V 2 1/2" P -3(A) P -2(A) 2 1 2 "WCO 2 1/2" L &3 "DN 1 1 /2" 2" SAN P -7 1 1/2" V 1/2" FLR. 1 1/2" 2 1/2" 4" TO SITE SAN � 2 1/2" -61- SAN 3 "SAN UP & 4 "SAN DN 2" 2 1/2" 1 1/2" 2 1 2 "WCO SECO\ 3 FLOOR SANITARY SEWER A \J SCALE: 1/4 ° =1' -0 2 "WCO 4 "WCO FIRST FLOOR SA \ITARY SEW SCALE: 1/4 ° =1' -0" 2 "SAN UP TO 3RD FLOOR & DN TO .1ST FLOOR 2 "SAN UP & 4 "SAN DN =R A 9 1) 4 "SAN (TYP P-1) P -6 FOR CONTINUATION SEE SHEET 1M11O 2" SAN - - +I- -- . — 4 "FCO 4 "V UP TO 4 "VTR 2" 1 1/2" VE \T PLA P-6 VE \T PLAN 2 "WCO ID 3/4" P-3 P -3 P -3 2 1/2"WCO 2 "WCO 2 1/2"SAN UP TO I 3RD FLOOR &3 "DN TO 1ST FLOOR 014 I4+ 1 1/2" 2 1/2" p -3 4 "SAN UP & DN P -2 (A) 2 1 /2 "WCO P -4 3 "SAN 2 "V 4 "V UP 2 "FD -1 2 1/2 "V P -3 2 1 /2 "WCO 2" C) z 1 1/2" 2 1/2" 4" 3 "SAN UP & DN • 1/2" NHA 3/4 1/2" • 1/2" WHA 3/4" itak Mir P-3 HB ACCESS PANEL; Z- P-3. SEE ARCH DWGS P--3 w CW P-3(A) 1 /2" /2 "TP P -2 P -2 P- 2(A) 1 1 /2 "CW . 3/4" -r- 1 1/21 1 \CW UP t . II is UP Al 17 R 11 I - r i1 ." 1 7 2 � '- HWC 14 C7 '•■ cw + Fiw .' — 1 /2 "TP 1"HWC UP & DN 1 "CW (TYP) no & DN— NP -1 n \ TRAP VALV 1/2' PRIM (TPV) TP WHA l � f - - 1 (A) 1 /2 "CW DN COMB T/P RELIEF VALVE TO FLOOR DR P -3 P -3 HB P-3 0 W C r { N PUMP P--7 WHA 1/2" 3/4" 1 /2" 3/4 WHA BOE /NG C' SECON J FLC3R HOT A\ D COLS WATER PLAN SCALE: 1 /4 _, '-0" 2 1/2" FIRST FLOOR HOT Fly] CCD WATER PLA SCALE: 1/4 "=1 -0" P -6 FOR CONTINUATION SEE SHEET 1M110 SUBTITLE TITLE MECHANICAL MASTER 3/4" 3/4" WHA 1/2" WHA 3/4' 3/4" 1 /2" WHA PU 2D5 100 GAL. 15KW, A.O.SMITH W/ EXPANSION TANK Y "HWC 3 /4"HW & CW TO BREAK ROOM S 1M110 FOR CO PLUMBING DETAIL PLANS BUILDING 13 -03 COL. C-D/5-6 LEGEND: DEV. CENTER, WA 1. SEE SHEET M1 a, M1 b, AND M 1 c FOR MECHANICAL LEGENDS AND ABBREVIATIONS. GENERAL NOTES: 1. SEE SHEET M501 & DETAIL L1 FOR M450 M507 DOMESTIC HOT WATER TANK PIPING. 2. FOR THIRD FLOOR PLUMBING DETAIL PLAN, SEE SHEET M453. 0 0\it.D f0( 0 91140) CURRENT REVISION - J #170567 -01 SHEET DWG NO. SYMBOL M450 JOB NO. MFC -95060 13- 03 -M450 RECEEIVF - JUN 0 5 2000 PERMIT CENTE DATE COMP NO. 03.14.08 60 DISCH. PLENUM 10 COIL SECT!, DIFFUSER SE• ION 2 DIFFUSER SECTION 7AH\ 1C7B FAN SECTION 2 1 /2 "1 " V' -t FILTER SECTION /8 "RL 1 I H; n/z • 4 MA---Z 60 -- 12/10 --.-BOD 10' --0" AFF w ,."r -&- -W-ill SF6 2'- 0 "(TYP) EXHAUST - - -7 DISCH. PLEN DISCH. PLENUM 10 COIL SECT!, DIFFUSER SE• ION - COIL SECTION DIFFUSER SECTION 7AH\ 1C7B FAN SECTION FILTER SECT ON V' -t FILTER SECTION /8 "RL MIXING BOX ( 5 I DISCH. PLEN 10 COIL SECT!, DIFFUSER SE• ION AH \ 1 C7A \ FAN SECT!. FILTER SECT ON MIXING BO 4 UNIT HTR /WALL BRKT, BTM UH @ 9' - AIR COMPRESSOR • rj HANGER DETAIL M451 M508 DAMPER #1 MIN. SETPT. 15% OPEN. 42/36 6' -0 "W X 3' -0 "H INTAKE LOUVER M451 M504 SHEET METAL BLANK -OFF --- 26/36 260 SA UP 48/21 RA DN TO AHU NOMINAL 6' -O" X 2' -6" X 1' -6" DEEP INTAKE PLENUM TO FIT AROUND STRUCT RAL STEEL CROSS- BRACING, FIELD VERIFY SI E. SEAL STRUCTURAL STEEL PENETRATIONS OF DUCTWORK AIR TIGHT. M451 M504 SCALE: 1/ SCALE: 1/ FOR CONTINUATION SEE SHT 1M10 LL 0 OD 6'- 0 "Wx2 --6 "H INTAKE LOUVER TYP. FIRST FLOOR MEC 0' Lt... LL N OA 0 co 0 • P M 0 4440 FIRST FLOOR 71 11 CO O vEC M4 51 -- M505 A \ICAL ROOv O 21 "CLWS 2Y "CLWR �1 "COND. DRAIN �4] 2 "FED- DATE PIP ST 8.12.96 10.13.97 Q 0 0 m N SYM M451 M508 COMPRESSOR CO 1D7 2 "G U LR, S 2r•OF \ \ \ \\ \`\\\ ( UH T�`, `\ 1D6' 1 \, I � EA(ABV) -OA(BELOW MOBILE A/C UNIT COMPRESSOR COOLING CONNECTION (TYP AIR, 5600 CFM rh 16 • 111) IOW IU 1 /2 "COND DRAIN - 1 "COND DRAIN- - 2"FFD-1 1 1/8"RL 1 5 /8 "RS PIT, SEE CT. DWGS. H ADL -2 LAB TO 2ND SHT. ► R CONT. A \ICAL ROO BOD 11' -2" AFF BOD 10' -10" AF 160 RA I 3.26.96 G MODIFY PLANT AIR CONNECTION -- HVAC 2" AIR SUPPLY TO BLD SEE SHT 1M110 3.14.96 F INSTALL WAFER BUTTERFLY VALVE AH 1C7B PIPI \G REVISION Alb M451 M505 s 320 RA UP iUa O <0 Le- 534363 -00 J #170567 -01 PL) 4 - 0 " W X 2' -6 "H EXH. LOUVER, TYP. (INTAKE PLENUM BELOW) 1 / PARTICULA FILTER 1 1/2" 1 1/2" -2" AIR COALESCING FILTER BY HARRAH RWS M.WONG LJ- LJ- 0 0 DESICCA DRYER AIR RECEIV APPROVED •• RWS RWS RWS SPENCE BLAST GATE #VLV- 90066 VF 1 D7 MOTORIZED EXHAUST DAMPER 4' -0 "W X 3' -6 "H EXH. LOUVER 3" AIR TO 13 -01 BLDG 8 >`"' \r- PIPE SLEEVE, TERMINATE 6" ABOVE WALKWAY SURFACE DATE 4.12.99 04.01.03 03.14.08 - -__ r BACKDRAFT DMPR -- I gligy fait I AND ACCESS PANEL 2' -O" 100 -1 > t moo BOD 10' -5 "AFF FOR CONTINUATION SEE SHEET 1 M 10 9 12/12 DN, TRANSITION TO FAN OUTLET, PROVIDE FLEX CONN. AT FAN. TYP 3" GATE VALVE IN VERTICLE. PROVIDE 3 "x2" BELL REDUCER, DIELECTRIC UNION, AND RUN 2" OVERHEAD TO AIR RECEIVER PIPING. 3" AIR TO MFC & PLANT SYSTEM SEE SHEET 1 M 110 1/2"COND FROM RECEIVER 1 /2 "COND.(FROM COALESCING FILTER) F OR S EE CONTINUATION SHT 1 60 rr�>��� M h 1! nn 4 »FFD -1 all I A ■ii i: b .1000. (1 • 2 1/2" SAFETY RELIEF DISCHARGE I. 18/18 EXHAUST LOUVER 6" UP TO 2ND FLR, SEE 2M12 w BOE /NG m El B 70, TYP AL E1A 14 14 r • BOD 10' -0" AFF 60 UNIT ` W /WALL BRK, BTM UH© 9 0" AFF SCALE: 1 /4 " =1 -0" 19'- '7 I" 1 UNIT HTR W /WALL BRKT I BTM UH @ 9' -O" AFF 1 12/12, BOD 8' -6 1/2 "AFF 100 DN, TRANSITION TO 70 IN RISER TRA TION 100 TO 70 70 IN RIS LEL 150 CFM SG \\/;) (TYP 4 5 w APPROVED BY. 18/18 EXHAUST LOUVER t :r. :ter 12/12 BOD 8' -6 1/2 "AFF FIRST FLOOR A \T TRA\S ROO ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED 120 FOR CONTINUATION SEE SHEET 1 M 1 O DEPT. BACKDRAFT DAMPER 10/8 1E1C (TYP) BOD @ "o�� _ = 2 1/2" CHWR /2" CHWS 80 DATE DRAWN M CAUNITIS CHECKED D. KLOTZ ENGINEER D. KLOTZ CHECKED G. SMITH APPROVED C. LYNCH AD APPROVED K. RAMBALDINI v DATE CONCRETE SUPPORT - -_� PAD, SEE CIVIL DWGS CH C 2.12.96 16' -0" PIPE SUPPORT STAND (TYP) SCH. 40 PIPE SLEEVE W/ ELASTOMERIC SEALANT 1 3 -0" IP Pr SUMP SUBTITLE El 3 /4 "CF t AN 1 p'j .-2 1/2" CHWS I 1 Q itr ----� 2 1/2" CHWR BOP @ 1 AL SCALE: 1/4"=1'-0" BOP 18 "AFF CHEMICAL FEED POT 3 /4 "CF Ak 3/4" �' -0 'AFF MJ 2 1/2" CHWR 0 �- FOR CONTINUATION SEE SHEET 1 M 10 Ab_E_i_ $� I SFD FOR CONTINUATION SEE SHEET 1 M 10 tiv. ce„4 g5 :174°- MECHANICAL DETAIL PLANS FLEX CONN IN RISER (TYP) • LEGEND: 1. SEE SHEET M1a, M1b, AND M1c FOR MECHANICAL LEGENDS AND ABBREVIATIONS. GENERAL NOTES: 1. FOR COOLING WATER SYSTEM P &ID, SEE SHT.M360. 2. SEE PLUMBING PLAN, SHT. 1 M11 O AND P &ID, SHEET M360, FOR PW FILL AND MAKEUP WATER SUPPLY TO CHILLED WATER SYSTEM. 2 1/2" CHWS & R TO LCS HEAT EXCHANGER. 4 3/4" CHWS & R TO FC77 HEAT EXCHANGER. © 3/4" CHWS & R TO WAVE GUIDE ANTENNA DUMMY LOAD. 6 > FOR COMPRESSED AIR SCHEMATIC, SEE SHEET M507. 8 > FOR CONTINUATION, SEE SHEET M452. 9 > FOR VENT. FAN INSTALLATION, SEE DETAIL 10 > FOR COIL CONN. & PIPING, SEE DETAIL 14 AIR RECEIVER, 200 GAL., 150 PSI, ASME RATED. FOR LOUVER LOCATION AND DESCRIPTION SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS. DAMPER N0.1 MINIMUM SETPOINT 15% OPEN. 30 FLEX SUPPLY DUCTS TO UPPER /LOWER EQUIPMENT RACK. 30 FLEX RETURN DUCTS TO UPPER /LOWER EQUIPMENT RACK. 20 FLEX DUCT TO EMI FILTER. 20KW DUCT HEATER FOR 26"0 DUCT. SCR CONTROLS FOR 4 -20 Ma SIGNAL OR 0-10 VOLT SIGNAL, 480 VOLT, 3 PHASE. CONSTRUCTION NOTES: 2. INSTALL PIPING LABELS ON ALL PIPING. CURRENT REVISION J #170567 --01 SHEET JOB NO. SYMBOL M451 MFC -95060 DATE COMP NO. M451 M503 Ak M451 M507 16 > 3" AIR UP, FOR CONTINUATION SEE SHEET 1M110. RETURN REDLINED PRINT BACK TO ENGINEERING WITH ANY DEVIATIONS FROM THE DESIGN. MOON WONG, 206- 947 -4897, M/C 46 -87 FABRICATE AND INSTALL 2YY" COOLING WATER SUPPLY AND RETURN FROM THE INDOOR LIEBERT A/C UNIT TO THE OUTDOOR LIEBERT DRYCOOLER. USE TYPE --L COPPER AND ALL INDOOR INCLUDING THE TRENCH PIPING SHALL BE INSULATED WITH 1" THICK GLASS FIBER .INSULATION. RECEIVED JUN 052008 PERMIT CENTER 03.14.08 AIL HUMIDITY REQUIREMENTS HARRAH SYM A B C D E INSTALL RELIEF VALVE REVISION BY 776018 —LO HARRAH APPROVED CL CL CL EJC RWS TITLE BUILDING 13 -03 (MECHANICAL) MASTER COL. X -X /X -X DEV. CENTER, WA DWG NO. 13- 03 -M451 7 T EXPANSION TANK EXTROL 35LBC 4 :: r r�► 4 ( AH ) 3E7 FILTER SECTION \\ \ / ; %/ \ / / CONDENSING \\// DX COIL FURNACE SUPPLY f� UNIT SECTION A SECTION SECTION FAN SECTION 1 \\ / \ \` / r /1 7 T EXPANSION TANK EXTROL 35LBC 4 :: r r�► SYM A B C D E M452 M504 PARTIAL PLAN L 7 1 SHT. METAL COLLAR SEAL WATERTIGHT WITH ELASTOMERIC SEALANT, TYP ECONOMIZER/ RETURN AIR FAN SECTION FIBERGLASS GRATING AT ROOF LEVEL, SEE ARCH. DWG'S TYP. CON CONDENSING UNIT II 0 J W ATION SEE SH 1 1/2' COND. DN TO FUNNEL, SEE ARCH. DWG'S FOR PIPING PITCH POCKET CD 1D7 I AH C3D7 SUPPLY FAN SECTION 3M10 300 FOR CONTINUATION SEE SHT. M451, PARTIAL PLAN PIPING P —TRAP FURNACE SECTION 1 1/4 "G UP _FROM 2nd FLR, CONNECT TO 'NIT GAS TRAIN WITH FLEX CONN. I I L -. —.� 5 /8 "ORL 1 1/8 "ORS 3 "A L 1 L 2 /30 J 4' 4" CONDENSING UNIT SECTION UTILIDOR, SEE CIVIL DRAWINGS �-- 2 "G _---- THREADED CAP ]� I J DISCHARGE PLENUM SCH. 40 STEEL PIPE SLEEVE UNDER CONC. WALKWAY CORE DRILL UTILIDOR & PROVIDE "LINK— SEAL" PIPING SLEEVE GAS METER AND PRESSURE REGULATOR BY PUGET SOUND ENERGY; DISCHARGE PRESS. SETPOINT I5 2 PSIG ELECTRICAL ROOM CONDENSING UNIT DISCHARGE AIR SHROUD THIRD FLOOR V M452 M514 A FIBERGLASS GRATING AT ROOF LEVEL, SEE ARCH. DWG'S TYP. DISCHARGE mom =muu ismoomm mmormor PLENUM ICAL AREA Pin P --TRAP 1 1/2" COND. DN TO FUNNEL, SEE ARCH. DWG'S FOR PIPING PITCH POCKET 1 1/2"G UP FROM 2nd FLR, CONNECT TO UNIT GAS TRAIN WITH FLEX CONN. ECONOMIZER /RETURN AIR FAN SECTION 6 J 3/4" COPPER COMP. AIR UP TO THE ROOF pied e -\‘%113°\) ; '' L l e \ 119 i\c #34 :"5fi 1. SEE SHEETS M1a, M1b, AND M1c FOR MECHANICAL LEGENDS AND ABBREVIATIONS. 1. FOR SEQUENCE OF OPERATION SEE SPECIFICATION SECTION 15956. 4. WHEN UNITS ARE SHUT OFF, OA DAMPERS WILL BE CLOSED, RA DAMPERS OPEN, AND EXHAUST DAMPERS CLOSED. LEGEND: CONTROL NOTES: AC3D7 & AC3E7 PROVIDE SA TEMP. RESET AS REQUIRED TO SATISFY ZONE WITH PEAK DEMAND. SITE CMOS TO PROVIDE OPTIMIZED START /STOP AND NIGHT SETBACK FUNCTION. GAS FIRED HEATING WILL BE STAGED FOR MORNING WARM —UP AND TO TEMPER MIXED AIR TO MAINTAIN 52T MINIMUM TEMPERATURE. PROVIDE 100% ECONOMIZER BASED ON ENTHALPY OF OA & RA. MECHANICAL COOLING SHALL BE CAPABLE OF OPERATING IN CONJUNCTION WITH THE ECONOMIZER. GENERAL NOTES: CONSTRUCTION NOTES: RETURN REDLINED PRINT BACK TO ENGINEERING WITH ANY DEVIATIONS FROM THE DESIGN. MOON WONG, 206 - 947 -4897, M/C 46 -87 EXTEND THE EXISTING HOUSE KEEPING PAD 2'-6" TOWARD EAST. INSTALL THE LIEBERT DRYCOOLER PER MANUFACTUREER INSTRUCTION. INSTALL THE PUMP PACKAGE PROVIDED BY LIEBERT PER MANUFACTUREER INSTRUCTION. INSTALL AN EXPANSION TANK PROVIDED BY LIEBERT PER MANUFACTUREER INSTRUCTION. FABRICATE AND INSTALL 2Y" COOLING WATER SUPPLY AND RETURN FROM THE INDOOR LIEBERT A/C UNIT TO THE OUTDOOR LIEBERT DRYCOOLER. USE TYPE —L COPPER AND ALL INDOOR INCLUDING THE TRENCH PIPING SHALL BE INSULATED WITH 1" THICK GLASS FIBER INSULATION. 6. USE DOW CHEMICAL, PROPYLENE GLYCOL (DOWFROST) 30% BY VOLUME. THE SYSTEM CAPACITY IS APPROXIMATELY 107 GALLONS. 7. INSTALL PIPING LABELS ON ALL PIPING. REVISION ISSUE FOR CONSTRUCTION 3" COMPRESSED AIR PROVIDE COMP. AIR OUTLET SEISMIC GAS SHUTOFF VALVE ADL -2 LAB BY 0567555 -00 HARR J #170567 -01 M.WONG APPROVED DATE MC DK MC DK CL CL 03.14.96 08.12.96 DMV 08.29.01 RWS 05.09.07 03.14.08 SYM REVISION BY APPROVED DATE Q,�BOE /NG° o r ACCEPTABILITY • THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN M.CAUNITIS CHECKED D.KLOTZ ENGINEER D.KLOTZ CHECKED G.SMITH APPROVED C.LYNCH APPROVED K.RAMBALDINI DATE SUBTITLE TITLE 02.12.96 MECHANICAL MASTER SECTIONS AND DETAILS BUILDING 13 -03 COL. C—F/6-7 DEV. CENTER, WA CURRENT REVISION J #170567 -01 SHEET JOB NO. DWG NO. SCALE: 1 /4" SYMBOL M452 MFC -95060 11 13 -03 —M452 _RECEIVED JUN 0 5 ZOOB "ERNIIT CENTER 4' DATE COMP NO. • 03.14.08 0. CO 1.6 N WONGK: 3/15/2008 COIL SECTION SYM A B C D ISSUE FOR CONSTRUCTION MANBAR DETAIL FULL FACE DIELECTRIC GASKET DIELECTRIC WASHER (2 PER BOLT) PIPE PIPE FLANGE- - STEEL BACKER WASHER, (TYP) DIELECTRIC SLEEVE PIPE PE SECURE D=TAIL SCALE: NONE SECURED SIDE FASTEN EXTERIOR FRAME ON SECURED SIDE TO WALL OPENING FRAMING. USE 1/4"O MIN SHT METAL SCREWS OR WELD EXTERIOR FRAME TO STRUCTURE 2 PLACES MIN EACH SIDE REVISION DUCTWORK (REF.) v A\ SCALE: NONE AS CLOSE AS POSIBLE ETRATIO 1/2 STEEL CROSS BARS WELDED TO INTERIOR FRAME AND AT ALL INTERSECTIONS, 6 "OC ACHSS ROOV NOTE: USE SIMILAR CONSTRUCTION FOR ROUND DUCT; IE, ROLL INTERIOR BAR AND EXTERIOR FLANGE (ROUND FLANGE CAN BE UNITED McGILL RRI IRON ANGLE RING). BAR DETAIL INSTALL SECURITY 2562008 ADDED MANBAR DETAIL 2 2562008 BY MC DK MC DK RWS RWS APPROVED CL CL RWS RWS NON— SECURED SIDE INSTALL PVC SLEEVE. SEAL ALL AROUND PENETRATION WITH ELASTOMERIC SEALANT NOTE: DIELECTRIC GASKET, WASHERS, AND BOLT SLEEVES ARE TO BE CALPICO OR APPROVED. PROVIDE 1/8" NEOPRENE —FACED PHENOLIC GASKET, 500 VOLTS PER MIL DIELECTRIC STRENGTH; 1/32" WALL HIGH DENSITY POLYETHYLENEE, OR PHENOLIC SLEEVE, AND 1/8" THICK PHENOLIC WASHERS WITH 1/8" STEEL BACKER WASHERS. 2M260,2M 110 DATE 3.14.96 8.12.96 04.27.06 05.01.06 SYM M506 3/8" CARRIAGE BOLT 12" Q.C. OR 2 PLACES MIN. EACH SIDE THRU INTERIOR FRAME, DUCT, AND EXTERIOR FRAME. INSTALL W/ BOLT HEAD ON INSIDE. DISTRESS THREADS AFTER ASSEMBLY. 2M 10,2M 11,2M 12,M503, M504 EXTERIOR FRAME 1 1/2"x 1 1 /2 "x3/16" ANGLE (TO FIT AROUND OUTSIDE OF DUCT) INTERIOR FRAME 1 1 /2 "x3/16" FLAT BAR (TO FIT SNUG INSIDE OF DUCT) M506 REVISION UNISTRUT SERIES P-2000 PIPE CLAMP UTILIDOR, SEE CIVIL DRAWINGS P -1000 UNISTRUT EMBED (REF) BY 4 APPROVED d r- I L SECTION SCALE: 1 1/2"=1'-0" 1 11- III III DATE III :• •(:1 -1 III 4 III I I - I I I I I I 1 1 1_ 1 11-1 1- 0 /N m P -1 000 UNISTRUT, ATTACH TO UTILIDOR WITH 1/2" EXPANSION SHELLS FINISHED GRADE M452 M506 2%11" GA INSERT " THICK INSULATION, TYP. vA \BAR SCALE: NONE TEEL BAR OVER 12 "SQ DUCT TYP > t/ OVER 12 "0 DUCT RIVET 6 "O.C. MAX TO 12" SQUARE DUCT 2"x 11 GA. INSERT TO 12 "o DU TYP RIVET 1 /2 "4STEEL BAR DUCT 1/2"SQ WIRE MESH BETWEEN CROSS BA 1/8 RIVET 1 /2"0 DUCT TYP ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. TYP > TYP > V /2 "OSTEEL BAR DATE 2 "x11 GA. INSERT DRAWN M. CAUNITIS CHECKED D. KLOTZ ENGINEER D. KLOTZ CHECKED G. SMITH APPROVED C. LYNCH APPROVED K. RAMBALDINI ATE 2.12.96 6 "MAX 6 "MAX SUBTITLE TITLE MECHANICAL MASTER RIVET 6 "MAX SECTIONS AND DETAILS BUILDING 13 -03 COL X—X/X—X LEGEND: 1. SEE SHEETS Mb, M1 b, M lc FOR MECHANICAL LEGENDS AND ABBREVIATIONS. GENERAL NOTES: DEV. CENTER, WA CONSTRUCTION NOTES: CURRENT REVISION 2562008 SHEET JOB NO. DWG NO. APPRO \,.......,„ IuN \ CM rA 40 SYMBOL M506 MFC -95060 13- 03 --M506 RECEIVED JUN 0 5 2008 PERMIT CENTER DATE COMP NO. 05.01.06 -.�- ��- ,� -----. 1/2x3/8 HEX BUSHING (TYP 2) WALL (REF) WALL V SCALE: NONE e SYMBOL U \ITEM DUPLEX AIR OUTLET DETAIL P -1000 UNISTRUT 4 9 LG W /(2) 1/4x2" TOGGLE BOLTS 1/4" QUICK DISCONNECT SOCKET 1M110,2M110,3M110 M452,M453 WALL (REF) SCALE: NONE ISSUE FOR CONSTRUCTION ADD BACKFLOW PREVENTER CHANGED AIR SCHEMATIC REVISION MODIFY PLANT AIR CONNECTION TRAP PRIMER VALVE DISTRIBUTION UNIT 4 OUTLET SUPPLY TUBING (TP) mu .... 534363 -00 TRAP PRIMER VALVE (TPV) MODEL DU-4 SUPPLY TUBING (TP) APPROVED 3.14.96 3.26.96 8.12.96 04.02.03 FUTURE EXTENSION TO 13 -01 BLDG. * FURNISHED WITH AIR DRYER REVISION 1 1/2"A FOR 13 -01 BLDG. 1 1/2"A TO 13 -03 BUILDING 2 1/2" TO RESTROOMS 1 1/2" T TRAP PRIMER VALVE 1 1/2" Cw -1(P E RI _1 I I DAY TIME AQUASTAT SETPOINT 100°F CIRC PUMP 0 PU 205 1 1/2 "A 1 -CI -- PRV-1/BP-2 PiPivc DETAIL SCALE: NONE HOT WAT SCALE: NONE APPROVED DATE 3/4 "DRAIN TO FFD TANK DRAIN PRV -1 SET @ 60 PSIG SCALE: NTS AFTERFILTER: WILKERSON F35, ' .5 MICRON PARTICULATE FILTER RATED AT 200 SCFM @ .3 PSID, CAST CAST ALUMINUM 0 -100 0-200 ..R HEATER PIPI PURGE AIR TO BLDG. EXTERIOR MUFFLER (TYP2) PURGE VALVE (TYP.2) COvPRESSED AIR SC Z) L Araw - zAw M450,M501 1 1 /2 "A I4I -+1+_ 1 /2" TO FLOOR DRAIN � 1M110 M507 AUTOMATIC DRAIN TRAP FIN. FLOOR EXPANSION TAN K AMTROL THERM—X—TROL MODEL ST -5, 2 GAL. SAFETY RELIEF SET AT 230 SCFM @ 125 PSIG 2"A PREFILTER: WILKERSON COALESCING FILTER, MODEL M32, 1 1/2" PORT, 1 MICRON, 200 SCFM @ 1.3 PSID LIQUID LINE FROM CONDENSING UNIT APPROVED BY LIQUID DISTRIBUTOR 200 GAL ASME RATED DEPT. DESIGN PRESSURE 150PSIG }H ci ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED 1"X 20 GA BAND STRAP EXPANSION VALVE - SCALE: NONE SCALE: NONE TO CONDENSING UNIT CONTACTOR DRAWN M. CAUNIT1S CHECKED D.K `INEE D.KLOTZ CHECKED G. SMITH APPROVED C.LYNCH APPROVED K. RAMBALDINI LOCKABLE VA (TYPICAL) 1/2" TO FLOOR DRAIN AUTOMATIC DRAIN VALVE DATE SOLENOID LIQUID VALVE 2.12.96 SUBTITLE 3/4 DUCT DIA RAISES FLOOR DUCT SUPPORT EXPANSION VALVE THERMAL BULB REFRIGERANT COIL PIPING DETAIL CAPILLARY TUBE (MECHANICAL) MASTER INSULATION, WHERE REQUIRED BY SPECIFICATIONS 3/4" FIRE RESISTIVE PLYWOOD 3/8" EXPANSION SHELL WITH WASHER, TYP 2 P1000 UNISTRUT BAND STRAP UNISTRUT P1026 i ANGLE FITTING, TYP DUCT NOT SHOWN FOR CLARITY 2M11,2M12 3'" GATE VALVE 3" X 2" BELL REDUCER DIELECTRIC UNION M451 M507 2" CAPPED CONNECTION FOR EMERGENCY COMPRESSOR AIR COMPRESSOR SECTIONS AND DETAILS BUILDING 13 -03 COL. X—X/X—X SUCTION LINE TO COMPRESSOR LEGEND: 1. SEE SHEETS Mb, M 1 b, AND M1 c FOR MECHANICAL LEGENDS AND ABBREVIATIONS. GENERAL NOTES: CONSTRUCTION NOTES: DEV. CENTER, WA REMOVE EXISTING 2" HOSE AND INSTALL NEW 2" COPPER AIR LINE BETWEEN EXISTING 3" VALVE AND AIR RECEIVER INLET AS SHOWN. PROVIDE ADDITIONAL LOCKING VALVE AT POINT OF CONNECTION TO AIR RECEIVER INLET PIPING. CURRENT REVISION 534363 -00 JOB NO. SYMBOL 13- 03 --M507 RECEIVED JUN 0 5 2008 PERMIT CENTER COMP NO. 04.02.03