Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M08-177 - WA STATE LIQUOR STORE
WA STATE LIQUOR CONTROL BOARD 14227 TUKWIL INTERNATIONAL BL Parcel No.: 1523049011 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Citylif Tukwila 14227 TUKWILA INTERNATIONAL BL TUKW WASHINGTON STATE LIQUOR STORE 14227 TUKVVILA INTERNATIONAL BL , TUKWILA WA SEG 56TH LLC 845 106TH AVE SE #100 , BELLEVUE WA Contact Person: Name: KEO TORRE Address: 727 S KENYON ST , SEATTLE WA Contractor: Name: EVERGREEN REFRIGERATION LLC Address: 727 S KENYON ST , SEATTLE WA Contractor License No: EVERGRL954R2 DESCRIPTION OF WORK: INSTALL (1) ROOF -TOP HVAC UNIT, (1) EXHAUST FAN, DUCTWORK , GRILLES AND DIFFUSERS Value of Mechanical: $20,000.00 Type of Fire Protection: Furnace: <100KBTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC-10/06 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT EOUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 0 1 0 0 1 0 0 0 * *continued on next page ** M08 -177 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 - 763 -1744 Phone: 206 763 -1744 Expiration Date: 01/06/2010 M08 -177 08/04/2008 01/31/2009 Fees Collected: $395.00 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP/1,750,000 BTU 0 Fire Damper 0 Diffuser 19 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 08 -04 -2008 Permit Center Authorized Signature: Print Name: doc: IMC -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa. SA Pki 4N9uz5d-✓ Permit Number: M08 -177 Issue Date: 08/04/2008 Permit Expires On: 01/31/2009 .f A.c—e . t/(/ Date: OM 1 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the rformance of work. I am authorized to sign and obtain this mechanical permit. Signature: Date: D / — b This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M08 -177 Printed: 08 -04 -2008 Parcel No.: 1523049011 Address: Suite No: Tenant: 14227 TUKWILA INTERNATIONAL BL TUKW WASHINGTON STATE LIQUOR STORE 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: M08 -177 ISSUED 07/09/2008 08/04/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Cond -10/06 * *continued on next page ** M08 -177 Printed: 08 -04 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: 5,4 M AA, V eh S'a -t doc: Cond -10/06 MO8 -177 Date: 6 ordinances governing or local laws regulating Printed: 08-04 -2008 Name: IteC Tov✓e. Mailing Address: is 5 • --t On fl • -Mail Address: Company Name: Mailing Address: Contact Person: it tot.) - 10 r/a-, E -Mail Address: Company Name: Mailing Address: Contact Person: E -Mail Address: CITY OF TUKWI Community Developmen epartment Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.lva.us Q \Applications\Forms - Applications On Line'3 -2006 - Mechanical Permit Application doc Revised' 4 -2006 bh MECHANICAL PERMIT APPLICATION Mechanical emit No. t40 3- 11 Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: Site Address: 0 1 -1 7 114.41 ZV4 f'' at ( ( / - Suite Number: Floor: I Tenant Name: TiN NI I-1 6'14M S - New Tenant: 10.... Yes 0 ..No Property Owners Name: S E 6 ( °6th five - SE Mailing Address: 39 r 10&f1' Five . 5E *100 vean feivt y-ru f �h 5. f od1.w' 59- F v1=(1- G0elf{- utic-cu Contractor Registration Number: "(/ Lt CtI Pe) le Ville City I SZ3 a y yu // l s y CONTACT PERSON - who do we contact when your permit is ready to be issued Day Telephone: 1 - 41 0 -- It" 3 — 1 1( ti 7COLl Zip City State Zip Fax Number: MECHANICAL CONTRACTOR INFORMATION - Mit 1,4- 9 PL' City State Zip Day Telephone: Z& — 7 b 3 — I `t Fax Number: 2 — ZEr 3 — 7 7 31 Expiration Date: l / a / / ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: Zip Contact Person: E -Mail Address: City Day Telephone: Fax Number: State ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record City Day Telephone: Fax Number: State Zip Page I of 2 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser (q 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended /Wall/Floor Mounted Heater Ventilation System f-(1140' le-a n , Wood /Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator— Comm /Ind Other Mechanical Equipment Valuation of Project (contractor's bid price): $ Zo Scope of Work (please provide detailed information): - 4-r I I (I) rc ff ' ✓ ^i f (s1 G q+ n diLkwwy- aad J; i ✓S . Use: Residential: New ....LI Replacement ....Et Commercial: New .... Replacement .... Fuel Type: Electric sj Gas Other: Indicate type of mechanical work being installed and the quantity below: PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Signature: Print Name: Yield 10 I`�_ / I Date Application Accepted: BUILDING OW ER OR AUTHORIZED AGENT: Mailing Address: - 1Z1 S- t' YLAI S� Date Application Expires: 0 \Applicationa\Fonns •Applications On Linei3.2006 • Mechanical Permit Application doe Revised 4.2006 bh Day Telephone: /7 tea State Zip City Date: 7 / / G - Staff Initials: lit Page 2 of 2 Parcel No.: 1523049011 Permit Number: M08 -177 Address: 14227 TUKWILA INTERNATIONAL BL TUKW Status: PENDING Suite No: Applied Date: 07/09/2008 Applicant: WASHINGTON STATE LIQUOR STORE Issue Date: Receipt No.: R08 -02488 City of Tukwila Initials: WER Payment Date: 07/09/2008 02:13 PM User ID: 1632 Balance: $0.00 Payee: EVERGREEN REFRIGERATION Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http.• / /www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 003187 395.00 ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES RECEIPT Account Code Current Pmts 000.322.102.00.0 316.00 000/345.830 79.00 Total: $395.00 Payment Amount: $395.00 4623 07/09 9 711 TOTAL. 4 53.00 doc: Receiot -06 Printed: 07 -09 -2008 Projee tt: ` �/ Type of I�nspect frkt Address: J f - Date Called: 222 Li .8 z____ Special Instructions: Date Wanted: , a.m. Requester: 4 Phone No: ...Z." _2 4 -62/y • INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 4/1/4 < C A/) Y le)eyese ri $60.00 REINSPECT! d I fEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Rate: Pro ecti In i bhl Gkiti.. Type of Inspection: - F - I 4 Address: Date Called: Special Instructions: Date Wanted: r. a.m G — ZS — a° Requester: Phone No: _ 266 — & : i8 INSPECTION RECORD Retain a copy with permit INSPE9ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 ci Approved per applicable codes. Corrections required prior to approval. lnsp Ei 60 00 REINSPECTION F ' REQUIRED Prior to inspection, fee must be ai at 6300 Southcenter lvd., Suite /00. Call to schedule reinspection. Rec: ip No.: Sw. ®_tom 1.- >J - Da Date: f11D ; -I�T7 0 Project: Type o n: Address: ; t' ` Date Called: .6 V C �S J (,¢t Special Instructions: Date Wanted: s (z , J �/ Q ,�m p.m. Requester: Phone ' 4 5 " I Approved per applicable codes. Receipt No.: Mo'' - I 7 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)4 -3670 El Corrections required prior to approval. COMMENTS: Inspe tor: Date: � El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: 4,r 0,1 Proj c t Type of Inspectign: A ` totte--(k Address: 11 22 1 _ 1 l J kW . k A,- Date Called: Special Instructions: �, / 6/ ` ((,� f 4/ A: : r � s r d( Date Wanted: a.m. Requester: Phone No 70G toriq - 342- MoV INSPECTION RECORD Retain a copy with permit INSPECTION O. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION IF+. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Approved per applicable codes. Corrections required prior to approval. COMMENTS: ot`- -- c / i J \ t PD r-e1SiAioNtk ebAl 't -r( —a C �- � ate, (� � � � f Ins pec o� r: a t Date —15 - o F ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: COMMENTS: L /9 ,1-i.---,-, Type of Inspection: / -- /�✓ ,� s pp'�� 1- , l�' „i4.... �i r /� �C f' !yi -, r � �. i Y Ce -/ Ly; ..I .`i Address: E E. Suite #: r C 'rn'f/, -_ Y.; e --A .SF :.> -I 04%! -J -1 .64�C.1. Monitor: Special Instructions: � r %'.sale k0 :..� / et . Phone No.: f 3 [r I J ; .' i / ( / Y ' �f°' S J "° E:�f" r`" � f '° :'.. , f e ,,.1. 1,..44 L21 , �^ � , z . +�" . L� / /" f ,,, !".',7 .�... f 9' Y -9" 4 / .,t 1 JP if cd : . 4/1 , Y ji \� Jf "Z' ,4 PA*I :t`�- .,J /:()•4) L./A'sg. :; 71) rte TCP /, *'t 5`i_i, rJ 7) "92,-4 7 ,L-e,... y , t i^S..?.17 / e' z ! I C • tiles �... f Ic. 5 Project: (-64-3-,512 -57 L /9 ,1-i.---,-, Type of Inspection: / -- /�✓ ,� s pp'�� 1- , l�' „i4.... �i r /� �C f' !yi -, r � �. i Y Ce -/ Ly; ..I .`i Address: E E. Suite #: r C Contact Person: 7 .r ° Monitor: Special Instructions: Pre -Fire: Phone No.: f 3 [r I J ; .' i / Needs Shift Inspection: f Sprinklers: Fire Alarm: / ` Hood & Duct: ° Monitor: / Pre -Fire: Permits: / Occupancy Type: 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 I VrApproved per applicable codes. ,Inspector: Date: 1' Hrs.: I I INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT Word /Inspection Record Form.Doc 1/13/06 f� f1 J..5 s i PERMIT NUMBERS Corrections required prior to approval. $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 Cooling Equipment Schedule Equip. ID Brand Name' Model No. Capacity Btu /h Total CFM OSA CFM or Econo? SEER or EER IPLV Location 1,5,7,8 1 , 5, LENNOX TGA036S2DS 36500 1200 240 13SEER 52000 ROOF RECEIVED � R�Y `� Lt�Vto c. P L IA OM �11i� !. JUL '0 9 MB 8... I4 L ' 77 1 7 CODE AP PROV D .JJL2 Heating Equipment Schedule Equip. ID Brand Name' Model No.' Capacity Btu /h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency 1,5,7,8 1 , 5, LENNOX TGA036S2DS 52000 1200 240 65000 52000 80.000 RECEIVED � R�Y `� Lt�Vto c. P L IA OM �11i� !. JUL '0 9 MB 8... I4 L ' 77 1 7 CODE AP PROV D .JJL2 Fan Equipment Schedule ► A Equip. ID Brand Name' Model No. CFM Spt HP/BHP Ili FI. Co UI ITIJ Wild ' EF -1 BROAN QTR110 90 0.20 71W B �, ° � - �� ^ RECEIVED JUL '0 9 MB 8... I4 L ' 77 1 7 PERMIT CENTEf Project Info Project Address Tukwila Liquor Store Date 7/9/2008 14227 International Blvd For Building Dept. Use Tukwila, WA Applicant Name: Evergreen Refrigeration Applicant Address: 727 S Kenyon st. Applicant Phone: 206 - 763 -1744 2006 Washington State Nonresidential Energy Code Compliance Forms Project Description Briefly describe mechanical system type and features. ❑ Includes Plans 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Summary MECH -SUM Revised July 2007 Install (1) rooftop packaged HVAC units and (1) rooftop exhuast fans. FELE COPY Include documentation requiring compliance with com i1 1 'r ia Compliance Option 0 Simple System 0 Complex System r ,OSystems Analysis' (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. ' 'If available. 2 As tested according to Table 14 -1A through 14 -1G. 3 If required. 4 COP, HSPF Combustion Efficiency, or AFUE, as „ avaiiavic. «a,vu ato,,v130QUMCR.J5b StJtgl I " tia6Fe�1Pd2 „ rr"ZIR ,TIFF, V8.FLPJJ lI , I 1-III1,I I uliy vl flu v CIO • applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). System Description See Section 1421 for full description of Simple System qualifications. If Heating/Cooling or Cooling Only: ❑ Constant vol? ❑ Split system? ❑ Air cooled? .i Packaged sys? ❑ <20,000 Btuh? ❑ Economizer included? If Heating Only: ❑ <5000 cfm? ❑ <70% outside air? Mechanical Summary (back) MECH -SUM Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. Heating Only 2006 Washington State Nonresidential Energy Code Compliance Form Econo Included? Air Cooled, Constant Vol? ingle Package U nit? <70% OSA <20,000 :tuh? plit Syste <=84,000 Btuh? Outd.. or Adjacent to utdoor ool Ca <54,000 Btuh? Use Complex Systems (section 1430) Yes - Yes* Reference Section 1421 Heating/Cooling or Cooling Only Yes Yes Reference Section 1423 Yes Yes otal Ca.. wo economize <24Q000 Btuh or 10 %? Yes Yes— No No Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. • Mechanical Permit Plans Checklist 2006 Washington State Nonresidential Energy Code Compliance Forms i MECH -CHK Revised July 2007 Project Address Tukwila Liquor Store 'Date 7/9/2008 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability I (yes, no, n.a.) Code Section Component Information Required. I Location I on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency Mi 1411.1 Combustion htg. Indicate intermittent ignition, flue/draft damper & jacket loss 1412 HVAC controls 1412.1 Temperature zones Indicate locations on plans Ml, M2 1412.2 Deadband control Indicate 5 degree deadband minimum Mi 1412.3 Humidity control Indicate humidistat 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types Mi 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage mi. 1412.4.2 Optimum Start Indicate optimum start controls 1412.5 Heat pump control Indicate microprocessor on thermostat schedule 1412.6 Combustion htg. Indicate modulating or staged control 1412.7 Balancing Indicate balancing features on plans Mi 1412.8 Ventilation Control Indicate demand control ventilation for high - occupancy areas 1422 Thermostat interlock Indicate thermostat interlock on plans 1423 Economizers Equipment schedule 1413 Air economizers 1413.1 Air Econo Operation Indicate 100% capability on schedule 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb 1413.2 Water Econo Doc Indicate clg load & water econoe & clg tower performance 1413.3 Integrated operation Indicate capability for partial cooling 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems 1414.1 Duct sealing Indicate sealing necessary mi. 1414.2 Duct insulation Indicate R -value of insulation on duct Mi 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Completion Requirements 1416.2.1 Commissioning Provide commissioning plan 1416.2.2 -3 Sys.Bal & Func.Test Indicate air and water system balancing & functional testing 1416.2.4 Commissioning Indicate O &M manuals, record drawings, staff training 1416.2.5 Comm. Report Indicate requirements for prelim. & final commissioning report Mi 1434 Separate air sys. Indicate separate systems on plans Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer Mi SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. 1441 Elec. water heater Indicate R - 10 insulation under tank 1442 Shut -off controls Indicate automatic shut -off 1443 Pipe Insulation Indicate R -value of insulation on piping 1452 Heat Pump COP Indicate minimum COP of 4.0 1452 Heater Efficiency Indicate pool heater efficiency 1453 Pool heater controls Indicate switch and 65 degree control 1454 Pool covers Indicate vapor retardant cover 1454 Pools 90+ degrees Indicate R -12 pool cover 2006 Washington State Nonresidential Energy Code Compliance Form 2006 Washington State Nonresidential Energy Code Compliance Form if "no" is circled for any question, provide explanation: 2006 Washington State Nonresidential Energy Code Compliance Form Meclian,ical Permit Plans Checklist MECH -CHIC 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14 -1G. If a nationally recognized certification program exists for a product covered in Tables 14 -1A through 14-1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings > 225,000 Btu/h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings > 225,000 Btu/h (65 kW), including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Cooling Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu /h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu/h) or less may be controlled by readily accessible manual off-hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: t Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stones in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings 1412.8 Ventilation Controls for High - Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu/h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246 - 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu/h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems • 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, EF CAE < 50 gal storage 0.58 0.71 50 to 70 gal storage 0.57 0.71 > 70 gal storage 0.55 0.70 2006 Washington State Nonresidential Energy Code Compliance Form Meclian,ical Permit Plans Checklist MECH -CHIC 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14 -1G. If a nationally recognized certification program exists for a product covered in Tables 14 -1A through 14-1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings > 225,000 Btu/h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings > 225,000 Btu/h (65 kW), including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Cooling Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu /h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu/h) or less may be controlled by readily accessible manual off-hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: t Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stones in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings 1412.8 Ventilation Controls for High - Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu/h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246 - 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu/h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems • 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, _ ,,,,,..,.,,,,,,,,«,,,.,?9,Qq s in x90,$ tglIg4Lq;;WpntiaLEnergy Code Compliance Farm -- - , - .- -. -. - -.- - outlets in the first story and levels below the first story of buildings duct runs are considered building envelope until they, three or more stories in height. 1. connect to the heating or cooling equipment, or 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum start controls shall be designed to automatically adjust the start time of an HVAC system each day to bring the space to desired occupied temperature levels immediately before scheduled occupancy. The control algorithm shall, as a minimum, be a function of the difference between space temperature and occupied setpoint and the amount of time prior to scheduled occupancy. 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start-up, set- up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shall indicate when supplemental heating is being used through visual means (e.g., LED indicators). 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu/h shall have modulating or staged combustion control. 000 EXCEPTIONS: 1. Boilers. 2. Radiant heaters. 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have a means for balancing, including but not limited to, dampers, temperature and pressure test connections and balancing valves. 2. are isolated from the exterior with an automatic shut-off damper complying with Section 1412.4.1. Once outside air ducts meat the above listed requirements, any runs within conditioned space shall comply with Table 14 -5 requirements. Other ducts and plenums shall be thermally insulated per Table 14 -5. Exceptions: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a zone that serves that zone. 1415 Piping Systems 1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14 -6. Exception: Piping installed within unitary HVAC equipment. Water pipes outside the conditioned space shall be insulated in accordance with Washington State Plumbing Code (WAC 51 -26) 1416 Completion Requirements (Refer to NREC Section 1416 and the Building Commissioning Guidelines, published by the Building Commissioning Association, for complete text and guidelines for building completion and commissioning requirements.) - 2,5::x8'2 8' 4'2'0 42,5 DIBBLE ENGINEERS -- ' FILE COPY LARRY'S STORAGE NEW HVAC UNIT STRUCTURAL CALCULATIONS TUKWIIILA, WA INCOMPLETE LTR #� 00° r77 PREPARED FOR: S.E. Grainger 56 LLC 845 106th Ave NE, Suite 100 Bellevue, WA 98004 1 EXPIRES 03/14/ ?owl Structural Calculations Project #: 08 -106 Prepared by Dibble Engineers, Inc. July 15, 2008 • REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 8 2008 _ Of Tu `ila BUI DING DIVISION RECEIVED JUL 17 2008 PERMIT CENTER t i DIBBLE ENGINEERS,INC. LARRY'S STORAGE NEW HVAC UNIT STRUCTURAL CALCULATIONS TUICWI LA, WA TABLE OF CONTENTS Section Number DESIGN CRITERIA 1 GRAVITY CALCULATIONS 2 LATERAL CALCULATIONS 3 DIBBLE ENGINEERS, INC. LARRY'S STORAGE NEW HVAC UNIT STRUCTURAL CALCULATIONS TUKWILA, WA SECTION 1 DESIGN CRITERIA Model Number 90/102 120 150 WEIGHT DATA Base Unit - The unit with NO OPTIONS. Max. Unit - The unit with ALL OPTIONS installed (Economizer. etc.). OPTIONS / ACCESSORIES ECONOMIZER / OUTDOOR AIR Economizer Economizer Outdoor Air Hood Outdoor Air Hood OUTDOOR AIR Outdoor Air Dampers Outdoor Air Damper Motorized Kit Power Exhaust Standard Static ROOF CURBS - STANDARD Down -Flow 14 In. height 4 in. height ROOF CURBS - CLIPLOCK 1000 Down -Flow •—� 14 in. height 18 in. height 24 in. height CEILING DIFFUSERS Step -Down • Flush • Transitions PACKAGING LTL Packaging (less than truck load) T -Class Packaged Gas / Electric 7.5 to 12.5 torts / Page 22 76 �i , TDN f-11/(s Base lbs. kg Net 1300 590 1355 615 1390 630 1525 692 1580 717 1615 733 1385 628 1440 653 1475 669 Max. lbs. kg TAREMD10 /15 LAOAHI O/15 TAOADMI O/15 LAOAD10/15 LAPEFIO /15 LARMF10 /15-14 LARMFI O /15-24 LARMF10/155 -14 LARMFIO /15S -28 LARMFI O/15S -24 RTD11 -95 RTD11 -135 RTD11 -185 FD11 -95 FD11 -135 FD11 -185 LASRT08 /10 LASRT10 /12 LASRT15 Shipping Base Max. lbs. kg lbs. kg 1610 730 1665 755 1700 771 Shipping Weights lbs. co 30 174 105 1 kg 59 14 117 11 53 5 82 37 126 57 79 189 52 71 86 88 205 392 75 174 289 30 32 36 40 93 178 34 79 131 14 15 16 48 (2521) 1 1 II 1 111 1 P 1 1 1 11 11 111 , I � (I III III1IIIIIIll I I' � 11III, I) I1IIII 11 g ll I 0 -_ 15 (381) (159) - 11) 4 20 (508) 28 mg (711) oo .. _.... z._ ac 99-114 (2521) -- � 11III, I) I1IIII 11 g ll I 0 -_ ft7i1lt�i'T7 ELECTRIC INLETS ma st GAS FL INLET OUTLET (FOR R 1300 1525 1355 1580 1390 1615 590 692 615 717 630 733 1385 1610 1440 1665 1475 1700 628 730 653 755 669 771 314 381 328 394 336 403 142 173 149 179 152 183 289 339 300 352 312 364 131 154 136 160 152 165 329 374 343 387 353 398 149 170 156 176 160 181 368 431 384 447 389 450 167 195 174 203 176 204 47 46 47 46 47 -1/2 46-1/2 1194' 1168 1194 1168 1207 1181 21 -1/2 23-1/2 21 -1/2 23-1/2 22 24 DIMENSIONS'- I ip*F ES(INI1111<) WEIGHTS CORNER WEIGHTS Model Net Shipping AA . BB . CC Number lbs. kg lbs. kg lbs. kg lbs. kg lbs. kg 090/102 Base Unit 090/102 Max. Unit 120 Base Unit 120 Max. Unit 150 Base Unit 150 Max. Unit Base Unit - The unit with low fire heat exchanger NO OPTIONS. Max. Unit - The unit with ALL OPTIONS Installed. (Economizer, High nput Heating and Controls) 4 (102) 58 (147s ? - 1 END VIEW AA 5-1/2 (140) / \ 5 1 FORKLIFT HORIZONTAL SUPPLY thk rru:s% 28 ( 711 1/, ( (159 EE IrIBOTTOM SUPPLY BOTTOM RETURN AIR OPENING AIR OPENING CENTER.. OF BOTTOM POWER/GAS ENT 5 s ti lmfies m (127x203m) DD I 31-1/4_0 ( I+ — (794) (5 28 (711) i GRAVITY 4 (102) HORIZONTAL RETURN SLOTS AIR OPENING AIR OPENING SIDE VIEW (Horizontal Openings) OD lbs. kg 3-1/2 FF (89) TOP VIEW Base Section SIDE VIEW 5-1/2 (140) CENTER OF GRAVITY EE.. .. FF inch mm inch mm BB CC HOLES ;DING) 546 597 546 597 559 610 T -Class Packaged Gas / Electric T.5 to 12.5 tons / Page 23 7.5 (. 12T143% ACCESSORY DIMENSIONS - STANDARD ROOF CURBS - DOUBLE DUCT OPENING TYPICAL FLASHING DETAIL FOR ROOF CURB FIBERGLASS INSULATION (Furnished) NAILER STRIP (Furnished) ROOF CURB (Extends around entire perimeter of unit) RIGID INSULATION (Field Supplied) BASE BOTTOM PACKAGED UNIT COUNTER FLASHING (Field Supplied) CANT STRIP • (Field Supplied) ROOFING MATERIAL NOTE — Roof deck may be omitted within confines of curb. DETAIL ROOF CURB J 1-13/16 (46) r ,__ 14 (356) 24 (610) --01 2 (51)10— 1 (26) FACTORY INSTALLED PERIMETER WOOD NAILER STRIP T -Class Packaged Gas / Electric 7.5 to 12.5 tons / Page 25 SK DIBBLE ENGINEERS, INC. Project No. ag.". Project Meg, k Efe40D447. Subject NAV VA--e. /T/ ir Frvarig fiv6- Sheet No. 51e -3 Date fag By HUG , f rig eq.) toc. .0f.014,:4 TO •:."Z) '; OP . uniir 6 --erx*ritver . 1 1 0 ((zpitanfs ii g ' 'At sr66i.eiguca) (5)Z)60 ez//e.c. Vfir 9icY 5t eaPii1Z eaMemt Vic 6 0 I txf Steles ;\ +Oa tJiJi Z.k1e7 (fa-- 541;tv) ro skesr/A/6. 2. o g Gs-Was Oi° 4 / ,7 To Itictorovc PV/ achti.5 0 zgfllo‘c, SrA-6-15,02.#y) DIBBLE ENGINEERS, INC. Project No. Project Lola t5 ct 1 6d Subject f', # mlg" 40 r /cm. ®,71 L CE_ Nom/ Sheet No. Date ‘f ,sld S B y . - SlmpsvAG „WS 1 /4 // 05x SG s 0 zy'ld4. art 5 off Vl ... UNtr < l3 Y 0T ipt,s H2.54 GLt /0 e o'GH rk>GS r rvt (5) fork-L. l cht 5 or,r �f x€( SG? 9 at2, TM' DIBBLE ENGINEERS, INC. LARRY'S STORAGE NEW HVAC UNIT STRUCTURAL CALCULATIONS TUKWILA, WA SECTION 2 GRAVITY CALCULATIONS DIBBLE ENGINEERS, INC. Project No. Project - t2- i s �' 672' - 2fs/nefrvtsZ. Subject Sheet No. Date By TSG A/61AI 1.4 Vitt,- 0117 - /c - It✓C'- 4 friow 6 r /OZ K Cltt 4r7 ✓.- 2 J) crats tv45'7.4(1,3.0 6 38 egiefre.sr- ese. (6w tr) () Z Lc tO NO Grio, /ydi-4, /.51//7" " /41 0/ 7/e -" g960.4' doe n -s 4,0-r /^i GGh1 ri zwi . s V tD f- e/' -G 4.).17 %C OW W 020 CZ) 2-)4i d 6.0uvtic -f 4.vv S ar.- (//v i r ) ve 5 r ark. 14/ ceitinst 4' aov e p- Dibble Engineers 25 Central Way, Suite 210 Kirkland, WA 98033 Rev, 580004 User: KW- 0608102, Ver 5.8.0.1- Nov -2000 • (e) 1983 -2006 ENERCALC Engineering Software Description existing 2x10 wl new HVAC e Section Name 2x10 Beam Width Beam Depth Member Type Bm WL Added to Loads Load Dur. Factor Beam End Fixity Wood Density Center Left Cantilever Right Cantilever Point Loads Dead Load Live Load ...distance Summary Span= 11.50ft, Beam Width = 1.500in x Max Stress Ratio Maximum Moment Allowable Max. Positive Moment Max. Negative Moment Max @ Left Support Max @ Right Support Max. M allow fb 1,096.45 psi Fb 853.88 psi Deflections Center Span... Deflection ...Location lbs 368.0 lbs 4.830 ft DL DL DL 1.500 In 9.250 in Sawn 1.150 Pin -Pin 45.000 pcf lbs lbs 0.000 ft 1.95 k -ft 0.00 k -ft 0.00 k -ft 0.00 k -ft 1.52 fv Fv Dead Load -0.088 in 5.750 ft ...Length/Defl . . 1,568.2 Camber ( using 1.5 * D.L. Deft) ... @ Center 0.132 in @ Left 0.000 in @ Right 0.000 in 20.00 #/ft #/ft #/ff General Timber Beam 54.15 psi 161.00 psi Center Span Left Cantilever Right Cantilever Hem Fir, No.2 Fb Base Allow Fv Allow Fc Allow E lbs lbs 0.000 ft Total Load -0.386 In 5.612 ft 357.50 General information Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Full Length Uniform Loads LL LL LL Reactions... Left DL Right DL Title : Dsgnr: Description : Scope: lbs lbs 0.000 ft 675.0 psi 140.0 psi 405.0 psi 1,100.0 ksi 33.00 #/ft #/ft #/ft Depth = 9.25in, Ends are Pin -Pin 1.284 : 1 2.0 k ft Maximum Shear *1.5 1.5 k -ft Allowable at 4.830 ft Shear. at 11.500 ft 0.14 k 0.14 k Left Cantilever... Deflection ...Length/Defl Right Cantilever... Deflection ...Length/Dell 11.50ft Lu ft Lu ft Lu lbs ibs 0.000 ft Job # Date: 10:44AM, 4 JUN 08 0.00 ft 0.00 ft 0.00 ft lbs lbs 0.000 ft Page lbs lbs 0.000ft Overstressed in Bending ! 0.8 k 2.2 k @ Left 0.54 k @ Right 0.48 k Camber. @ Left 0.000 in @ Center 0.132 in @ Right 0.000 in Max 0.54 k Max 0.48 k Dead oad Total Load 0.000 in 0.000 in 0.0 0.0 0.000 in 0.000 in 0.0 0.0 Dibble Engineers 25 Central Way, Suite 210 Kirkland, WA 98033 Rev: 580004 User: KW -0606102. Ver 5.8.0;1 -Nov -2006 (0)1983 -2005 ENERCALC En_. veering Software Description existing 2x10 w/ new HVAC Title : Dsgnr: Description : Scope: General Timber Beam Job # Date: 10:44AM, 4 JUN 08 Page 2 Stress Calcs Bending Analysis Ck 30.529 Cf 1.100 @ Center @ Left Support @ Right Support Shear Analysis Design Shear Area Required Fv: Allowable Bearing @ Supports Max. Left Reaction Max. Right Reaction Query Values M, V, & D @ Specified Locations @ Center Span Location = @ Right Cant. Location = @ Left Cant. Location = Rona =0.60 Vacs ®o = oec Le 0.000 ft Rb 0.000 Max Moment 1.95 k -ft 0.00 k -ft 0.00 •k -ft @ Left Support 0.75 k 4.667 in2 161.00 psi Vriffic 2.0k41 Dam = .03801n 0.54 k 0.48 k 0.00 ft 0.00 ft 0.00 ft d:11�1�1; ►d� t,J� �S�d� 1ll�1111 ;i Sxx 21.391 in3 CI 0.000 S)oi Reo'd 27.47 in3 0.00 in3 0.00 in3 @ Right Support 0.66 k 4.118 in2 161.00 psi Moment 0.00 k -ft 0.00 k -ft 0.00 k -ft Amax 0.6k 15680 are 0.6k Bearing Length Req'd Bearing Length Req'd Bendi>ig Momoills 034 0.45 0.38 oat 0. 0 4 2 os I a.n 424 ale 440 Seem hen 4.34 aw AD g a.n 421 420 A .so Defle Area 13.875 in2 Allowable fb 853.88 psi 853.88 psi 853.88 psi 0.884 in 0.797 In Shear 0.54 k 0.00 k 0.00 k Locedlon rs 1.0agbn ten Deflection 0.0000 in 0.0000 in 0.0000 in 1 \ ' A .. ft __r. M_il_ L41 213 .43 37 3.72 088 01 6.10 .33 - Dibble Engineers 25 Central Way, Suite 210 Kirkland, WA 98033 Rev: 580004 User: KW -0606102. Ver 5.8.0;1 -Nov -2006 (0)1983 -2005 ENERCALC En_. veering Software Description existing 2x10 w/ new HVAC Title : Dsgnr: Description : Scope: General Timber Beam Job # Date: 10:44AM, 4 JUN 08 Page 2 Stress Calcs Bending Analysis Ck 30.529 Cf 1.100 @ Center @ Left Support @ Right Support Shear Analysis Design Shear Area Required Fv: Allowable Bearing @ Supports Max. Left Reaction Max. Right Reaction Query Values M, V, & D @ Specified Locations @ Center Span Location = @ Right Cant. Location = @ Left Cant. Location = Rona =0.60 Vacs ®o = oec Le 0.000 ft Rb 0.000 Max Moment 1.95 k -ft 0.00 k -ft 0.00 •k -ft @ Left Support 0.75 k 4.667 in2 161.00 psi Vriffic 2.0k41 Dam = .03801n 0.54 k 0.48 k 0.00 ft 0.00 ft 0.00 ft d:11�1�1; ►d� t,J� �S�d� 1ll�1111 ;i Sxx 21.391 in3 CI 0.000 S)oi Reo'd 27.47 in3 0.00 in3 0.00 in3 @ Right Support 0.66 k 4.118 in2 161.00 psi Moment 0.00 k -ft 0.00 k -ft 0.00 k -ft Amax 0.6k 15680 are 0.6k Bearing Length Req'd Bearing Length Req'd Bendi>ig Momoills 034 0.45 0.38 oat 0. 0 4 2 os I a.n 424 ale 440 Seem hen 4.34 aw AD g a.n 421 420 A .so Defle Area 13.875 in2 Allowable fb 853.88 psi 853.88 psi 853.88 psi 0.884 in 0.797 In Shear 0.54 k 0.00 k 0.00 k Locedlon rs 1.0agbn ten Deflection 0.0000 in 0.0000 in 0.0000 in Dibble Engineers 25 Central Way, Suite 210 Kirkland, WA 98033 General Timber Beam Description existing 2x10 wl new HVAC I General information Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Section Name 2-2x10 Beam Width Beam Depth Member Type Bm Wt. Added to Loads Load Dur. Factor 1.150 Beam End Fixity Pin -Pin Wood Density 45.000 pcf Full Lentath Uniform Loads Center Left Cantilever Right Cantilever Point Loads Dead Load Live Load ...distance Summary Deflections Center Span... Deflection ...Location _ ...Length/Defl Camber ( using 1.5 * @ Center @ Left @ Right lbs 368.0 lbs 4.830 ft Maximum Moment Allowable Max. Positive Moment Max. Negative Moment Max @ Left Support Max @ Right Support Max. M allow tb 567.82 psi Fb 853.88 psi DL DL DL 3.000 in 9.250 In Sawn lbs lbs 0.000 ft 0.00 k -ft 0.00 k -ft 3.04 fv Fv Dead Load -0.052 in 5.750 ft 2,662.1 D.L.Defi)... 0.078 In 0.000 in 0.000 in 2.02 k -ft 0.00 k -ft 20.00 #/ft . #/ft #/ft Span= 11.50ft, Beam Width = 3.000in x Depth = 9.25in, Ends are Pin -Pin Max Stress Ratio 0.665 ; 1 2.0 k -ft 3.0 k -ft at 4.830 ft at 11.500 ft 2825 psi 161.00 psi lbs lbs 0.000 ft Center Span Left Cantilever Right Cantilever Hem Fir, No.2 Fb Base Allow Fv Allow Fc Allow E Total Load -0.201 in 5.812 ft 687.11 LL LL LL Reactions... Left DL Right DL Title : Dsgnr: Description : Scope: lbs lbs 0.000 ft 11.50 ft ft ft 675.0 psi 140.0 psi 405.0 psi 1,100.0 ksi 33.00 #/ft #/ft #/ft 0.8 k 4.5 k @ Left 0.57 k @ Right 0.51 k Camber. @ Left t 0.000 in @ Center 0.078 in @ Right 0.000 In Maximum Shear *1.5 Allowable Shear: 0.16 k 0.16 k Left Cantilever... Deflection ...Length/Defl Right Cantilever... Deflection ...Length/Defl Lu Lu Lu Ibs lbs 0.000ft Job# Date: 10:44AM, 4 JUN 08 0.00 ft 0.00 ft 0.00 ft lbs lbs 0.000 ft Beam Design OK Max 0.57 k Max 0.51 k Dead Load Total Load 0.000 in 0.000 in 0.0 0.0 0.000 in 0.000 in 0.0 0.0 lbs lbs 0.000ft Dibble Engineers 25 Central Way, Suite 210 Kirkland, WA 98033 Rev: 580004 User: KW -0608102. Ver 5.8.0, 1- Nov-2008 _ (c)1983 -2006 ENERCALC Engineering Software General Timber Beam Page 2 Description Stress Calcs Bending Analysis Ck 30.529 Cf 1.100 @ Center @ Left Support @ Right Support Shear Analysis Design Shear Area Required Fv: Allowable Bearing @ Supports Max. Left Reaction Max. Right Reaction Rmal a 0.00 Vrnax a Ie0 a 0.13k existing 2x1 0 w/ new HVAC Le Rb M, V, & D @ Specified Locations @ Center Span Location = @ Right Cant. Location = @ Left Cant. Location = T toll 0.000 ft 0.000 Max Moment 2.02 k-ft 0.00 k -ft 0.00 k -ft @ Left Support 0.78 k 4.870 in2 161.00 psi 4rmat a 7-Do-fl haw = -0.20tin 0.57 k 0.51 k 0.00 ft 0.00 ft 0.00 ft Scope : Sxx 42.781 in3 CI 0.000 Sxx Read 28.45 in3 0.00 in3 0.00 in3 @ Right Support 0.70 k 4.321 in2 161.00 psi Raw = 0 6k Vaw @ n =0.6k Title : Dsgnr: Description : Bearing Length Req'd Bearing Length Req'd Moment 0.00 k -ft 0.00 k-ft 0.00 k -ft 0.07 0.47 098 47 .20 0.A 008 r' O A -0A1 Beam hear 0.00 4702 -0M 47.07 -0.00 -0.11 -0.O -0-010 -0.10 -0.20 Della fi u Area 27.750 in2 Allowable fb 853.88 psi 853.88 psi 853.88 psi 0.468 in 0.419 In Shear 0.57 k 0.00 k 0.00 k LooNlon mt Job # Date: 10:44AM. 4 JUN 08 Deflection 0.0000 in 0.0000 in 0.0000 in L4 l ' I olommi II AEI « 3.247 n A7 5.73 di0 O.1D 30 Dibble Engineers 25 Central Way, Suite 210 Kirkland, WA 98033 Rev: 580004 User: KW -0608102. Ver 5.8.0, 1- Nov-2008 _ (c)1983 -2006 ENERCALC Engineering Software General Timber Beam Page 2 Description Stress Calcs Bending Analysis Ck 30.529 Cf 1.100 @ Center @ Left Support @ Right Support Shear Analysis Design Shear Area Required Fv: Allowable Bearing @ Supports Max. Left Reaction Max. Right Reaction Rmal a 0.00 Vrnax a Ie0 a 0.13k existing 2x1 0 w/ new HVAC Le Rb M, V, & D @ Specified Locations @ Center Span Location = @ Right Cant. Location = @ Left Cant. Location = T toll 0.000 ft 0.000 Max Moment 2.02 k-ft 0.00 k -ft 0.00 k -ft @ Left Support 0.78 k 4.870 in2 161.00 psi 4rmat a 7-Do-fl haw = -0.20tin 0.57 k 0.51 k 0.00 ft 0.00 ft 0.00 ft Scope : Sxx 42.781 in3 CI 0.000 Sxx Read 28.45 in3 0.00 in3 0.00 in3 @ Right Support 0.70 k 4.321 in2 161.00 psi Raw = 0 6k Vaw @ n =0.6k Title : Dsgnr: Description : Bearing Length Req'd Bearing Length Req'd Moment 0.00 k -ft 0.00 k-ft 0.00 k -ft 0.07 0.47 098 47 .20 0.A 008 r' O A -0A1 Beam hear 0.00 4702 -0M 47.07 -0.00 -0.11 -0.O -0-010 -0.10 -0.20 Della fi u Area 27.750 in2 Allowable fb 853.88 psi 853.88 psi 853.88 psi 0.468 in 0.419 In Shear 0.57 k 0.00 k 0.00 k LooNlon mt Job # Date: 10:44AM. 4 JUN 08 Deflection 0.0000 in 0.0000 in 0.0000 in L4 Dibble Engineers 25 Central Way, Suite 210 Kirkland, WA 98033 Rev: 880004 User. KW -0506102, Ver 5.8.4. 1- Nov -2008 Ic} 1983.2006 ENERCALC Engineering Software General Timber Beam Page 1 Description General Information Section Name 2x10 Beam Width Beam Depth Member Type Bm Wt. Added to Loads Load Dur. Factor Beam End Fixity Wood Density Center Left Cantilever Right Cantilever Dead Load Live Load ...distance lbs 105.0 lbs 4.830 ft Summary Deflections Center Span... Deflection ...Location _ . ... Length/Defl Camber ( using 1.5 * D. @ Center @ Left @ Right existing 2x10 w/ new HVAC y pyr -,_ C r - DL DL DL 1.500 in 9.250 In Sawn 1.150 Pin -Pin 45.000 pcf lbs lbs 0.000 ft Span= 11.50ft, Beam Width= 1.500In x Max Stress Ratio Maximum Moment Allowable Max. Positive Moment Max. Negative Moment Max @ Left Support Max @ Right Support Max. M allow fb 683.49 psi Fb 853.88 psi 1.22 k -ft 0.00 k -ft 0.00 k -ft 0.00 k -ft 1.52 fv Fv Dead Load -0.088 In 5.750 ft 1,568.2 L. Deft)... 0.1321n 0.000 in 0.000 in Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined 20.00 #/ft #/ft #aft 37.66 psi 161.00 psi Center Span Left Cantilever Right Cantilever Hem Fir, No.2 Fb Base Allow Fv Allow Fc Allow E lbs lbs 0.000 ft Total Load -0.258 in 5.704 ft 534.33 LL LL LL Title : Dsgnr: Description : Scope: _ Full Length Uniform Loads Point Loads Reactions... Left DL Right DL lbs lbs 0.000 ft Depth = 9.251n, Ends are Pin-Pin 0.800 : 1 1.2 k -ft 1.5 k -ft at 4.968 ft at 11.500 ft 11.50 ft ft ft 675.0 psi 140.0 psi 405.0 psi 1,100.0 ksi 33.00 #/ft #/ft #/ft 0.5 k 2.2 k @ Left 0.39 k @ Right 0.37 k Camber. @ Left 0.000In @ Center 0.1321n @ Right 0.000in Maximum Shear * 1.5 Allowable Shear. 0.14 k 0.14 k Left Cantilever... Deflection ...Length/Deft Right Cantilever... Deflection ...Length/Defl Lu Lu Lu lbs lbs 0.000 ft Job # Date: 10:49AM, 4 JUN 08 Max 0.39k Max 0.37 k Dead Load 0.000 in 0.0 0.000 in 0.0 0.00 ft 0.00 ft 0.00 ft lbs lbs 0.000 ft Total Load 0.000 in 0.0 0.000 in 0.0 lbs lbs 0.000 ft Beam Design OK 31 0m ' 1 !$ e e d R R C 1 f i I . L11 225 - 22 1.57 ...1. 0.79 5.50 621 2.10 4.20 Dibble Engineers 25 Central Way, Suite 210 Kirkland, WA 98033 Description Bending Analysis Ck 30.529 Cf 1.100 @ Center @ Left Support @ Right Support Shear Analysis Design Shear Area Required Fv: Allowable Bearing @ Supports Max. Left Reaction Max. Right Reaction Sketch & Diagram Rmex 0Ak Virtu a left a 0.411 existing 2x10 w/ new HVAC Le 0.000 ft Rb 0.000 Max Moment 1.22 k -ft 0.00 k -ft 0.00 k -ft @ Left Support 0.52 k 3.246 in2 161.00 psi M, V, & D @ Specified Locations @ Center Span Location = @ Right Cant. Location = @ Left Cant. Location = 2,40Er Omer = •e.258in 0.39 k 0.37 k 0.00 ft 0.00 ft 0.00 ft Sxx CI �P+ i>' i' T�► it�y�I/ TII7T7if1f���� /i1'/1i111'�1���� 5341 21.391 in3 0.000 S>ot Read 17.12 in3 0.00 in3 0.00 in3 @ Right Support 0.50 k 3.089 1n2 181.00 psi Moment 0.00 k -ft 0.00 k-ft 0.00k -ft Roux n OAk V.000 rt 0.4k .8 g 8 Da Title : Dsgnr. Description : Scope : Rev: 580004 User. KW-0608102, Ver 5.8.0,1-Nov-2008 loll 983 -2008 ENERCALC Engineering Software General Timber Beam Stress Calm Bearing Length Req'd Bearing Length Req'd 030 0.91 0.2.3 020 0.n 0.0? S no .new vi 4 439 437 Beam %hear Area 13.875 1n2 Allowable fb 853.88 psi 853.88 psi 853.88 psi 0.643 in 0.615 in Shear 0.39 k 0.00 k 0.00 k • 11 225 912 .57 323 Location (In Location Mt Job # Date: 10:49AM, 4 JUN 08 Deflection 0.0000 in 0.0000 In 0.0000 in .00 6.01 0.10 DIBBLE ENGINEERS, INC. Project No. Project G2 t' 5 g r2az Subject Sheet No. Date / l e) By BS /1/45%) • •t -'jJ 14// 4•00. kv u,+-kr e /Wage- ,ed',rc 067 . 3C e _ j L'55 -. 'rte 5 45-0' 5,24(1 ' ft-' `l ti) 1 frlp- 51 0 / ' ! o. c . Timber Column Capacity By: TSC Date: 5/8/2008 Codes Used: 2001 NDS and Supplement Member Dimensions: let = : ;`?0:5" ?,` FT Effective Col. Length L :20:0 :i;Ff d _ ' 3 :" : IN Section Dimension d2= ,..'.F55.:` IN (I, / d), = 43.64 Design Assumptions: Hem -Fir - No. 2 (NDS Supplement Table 4A) F,= 800 PSI E = 1,200,000 PSI Equations: Fe F,* Co * C * Ct* C * Cr" Cp (NDS Table 4.3.1) E'= E * CM * Ct * C1 * C . F� *= F * CD * Cv, * Ct * CF * Ci FeE = K E /(I,/d) KBE = 0.510 - 0.839 *(COVE) Factors: Co = 1.15 Snow Load (NDS 4.3) C = 1.00 Dry Ct = 1.00 5 100 ° F CF = 1.05 Size Ftr. C = 1.00 No Incising Cp = see eqn Column Stability (NDS 3.7) CT = 1.00 Only for 2" x 4" or smaller Adjustments: Analysis: (COV = 0.25 Visually Graded Lumber c = 0.80 Sawn Lumber 0.15 Machine Evaluated Lumber 0.85 Round Timber Poles & Piles 0.10 Giulam 0.90 Glulam, Str. Composite Lumber USE: (COVE) = 0.25 USE: c = 0.80 F, *= 966 PSI = 1,200,000 PSI Kc5 = 0.300 FEE = 189.22 PSI (F / F *) = 0.196 Cp = 0.187 F� 180.89 PSI Column Capacity= 2984.6 LBS Combined axial compression and bending in d2 direction: uniform wind load w = Axial compressive load p = M of I about 2 fb = fc = 7 plf 1435 lbs 41.59 inM 278 psi 87 psi CSI = 0.89 <1.0? Fb= Cd = Cm = Ct = CL = Of = Cr = Fb'= 0 675 1 1 1 1 1 1.15 776 Possible CD values: 0.90 Dead Load 1.00 Live Load 1.15 Snow Load 1.25 Construction Load 1.33 WInd/Egk Load 1.33 Impact Load DIBBLE ENGINEERS, INC. LARRY'S STORAGE NEW HVAC UNIT STRUCTURAL CALCULATIONS TUICWILA, WA SECTION 3 LATERAL CALCULATIONS Period, sec RACE Ss, g 0.00 0.662 0.11 1.406 } 1.406 0.52 1.406 0.60 1.228 0.78 1.053 0.80 0.921 0.90 0.819 1.00 G " C -' - =J --i ;-- 0.614 1.30 0.567 1.40 0.526 1.50 0.451 1.60 0.481 .` , 0.433 1.80 0.409 1.00 0.388 2.00 0.368 + -__ r r�rrrnrrr� * ...__ �, Period, sec RACE Ss, g 0.00 0.662 0.11 1.406 0.20 1.406 0.52 1.406 0.60 1.228 0.78 1.053 0.80 0.921 0.90 0.819 1.00 0.737 1.10 0.670 1.20 0.614 1.30 0.567 1.40 0.526 1.50 0.451 1.60 0.481 120 0.433 1.80 0.409 1.00 0.388 2.00 0.368 1.6 a 0.8 0.6 0. y 0.4 02 Maximum Considered Earthquake Ground Motion Site Class D Fa = 1.00 Fv = 1.52 Zip Code = 98168 Central Lat. = 47.488839 deg Central Long. = - 122.29991 deg 0 0 0.5 1 Period, sec 1.5 2 MCE Ground Motion - Conterminous 48 States Zip Code - 98168 Central Latitude = 47.488839 Central Longitude = - 122.29991 Period MCE Sa (sec) ( %g) 0.2 140.6 MCE Value of Ss, Site Class B 1.0 048.5 MCE Value of S1, Site Class B Spectral Parameters for Site Class D 0.2 140.6 Sa = FaSs, Fa = 1.00 1.0 073.7 Sa = FvS1, Fv = 1.52 Spectrum for Site Class D Period MCE Sa (sec) ( %g) 0.000 056.2 T = 0.0, Sa = 0.4FaSs 0.105 140.6 T =To, Sa= FaSs 0.200 140.6 T = 0.2, Sa = FaSs 0.524 140.6 T = Ts, Sa = FaSs 0.600 122.8 0.700 105.3 0.800 092.1 0.900 081.9 1.000 073.7 T =1.0, Sa = FvS1 1.100 067.0 1.200 061.4 1.300 056.7 1.400 052.6 1.500 049.1 1.600 046.0 1.700 043.3 1.800 040.9 1.900 038.8 2.000 036.8 .5 vs Y. 6 /06 ( t) iP-/ 37 � DIBBLE ENGINEERS, INC. Project No. Project Subject Sheet No. Date By $1-k titL Mv4e Cm/ a Yap Sos wp 0 4 2 , e a p= Z4 . np rn =/.v =-1.c) m'm-s dos = 0,137 w (/4 Z(l.') -- 0.90" We y6y( /Ev) - 6 /dam Pte= 1°74- 4 /36 4A '1,q'; frog 4 /56 (Z t3 ) = qa 7 " I res br (1,7y) - Z 3 Z7. `i A5Ge 7 -PC 0.0 . m cif 7 -ac §)Z. G rmlue /y4 Pr ..'a 410 042.1'U2,/ Ave O/iceFT r Grr DIBBLE ENGINEERS, INC. Project No. Project Subject Sheet No. Date By V`= 9361` Jig" 1/W 3.i . 5 scelow -� (, 0) S// /aaa 1 %4 / W 1 s ite 4•zv6- Sps cr 1t/s C J HZ,S4 GL / per- Ui✓. T DIBBLE ENGINEERS, INC. Project No. Project Subject Sheet No. Date By V '/36 % 't o X ,j .Y . 505 Sc 4aw -� y - 5 L, t 4' 5r/4~N / /c/CA 7 /Y Ca`41G Spy 6444511/5 HZ,SA- GL /Ps 0 vi✓ . July 12, 2008 Key Torre 727 South Kenyon Street Seattle, WA 98108 • City of f Tukwila Department of Community Development RE: Letter of Incomplete Application # 1 Development Permit Application M08 -177 WA State Liquor Control Board — 14227 Tukwila International BI Dear Mr. Torre, • Jim Haggerton, Mayor This letter is to inform you that your permit application received at the City of Tukwila Permit Center on July 9, 2008 is determined to be incomplete. Before your application can continue the plan review process the following items from the following department needs to be addressed: Building Department: Allen Johannessen at 206 433 -7163 if you have any questions concerning the attached comments. Please address the comment above in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Brenda Holt Permit Coordinator Enclosures File: M08 -177 P:\Permit Center\Incomplete Letters\2008U■108 -177 Incomplete Ltr # 1.DOC jem Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 - 3670 • Fax: 206 - 431 -3665 Date: July 10, 2008 Project Name: Washington State Liquor Store Permit #: M08 -177 Plan Review: Allen Johannessen, Plans Examiner Determination of Completeness Memo i Tukwila Building Division Allen Johannessen, Plan Examiner I■ The Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. New mechanical equipment to be installed on the roof exceeding 400 pounds shall require an engineer's analysis for the roof structure with calculations to show the roof structural members are sufficient for the combined loads imposed by all the mechanical equipment. Provide details with the engineer's calculations. In addition, details shall show how units secure to the curbs to resist wind and seismic loads. All engineer's documents shall be original wet stamped and signed by the engineer. (IMC 106.3.1, 301.12, Section 302, IBC 16062) Should there be questions concerning the above requirements, contact the Building Division at 206 -431 -3670. No further comments at this time. ACTIVITY NUMBER: M08 -177 DATE: 07 -17 -08 PROJECT NAME: WA STATE LIQUOR CONTROL BOARD SITE ADDRESS: 14227 TUKWILA INTERNATIONAL BL Original Plan Submittal Response to Correction Letter # X Response to Incomplete Letter # 1 Revision # After Permit Issued Public Works Complete Comments: PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP n rv Fire Prevention Structural Incomplete DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Planning Division ❑ Permit Coordinator DUE DATE: 07 -22 -08 Not Applicable Permit Cerifei Use Only .; n ; INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS RO TING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 DATE: DATE: n DUE DATE: 08-19-08 Not Approved (attach comments) ❑ Permit Center Use Only . . • ' - • CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: M08 -177 DATE: 07 -09 -08 PROJECT NAME: WASHINGTON STATE LIQUOR STORE. SITE ADDRESS: 14227 TUKWILA INTERNATIONAL BL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Bui t1n• isio Public Works ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: REVIEWER'S INITIALS: Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP r L 6/1 w1G, / Fire Prevention Structural ❑ Incomplete Permit Center,Use•Only' INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg 0 Fire ❑ Ping ❑ PW ❑ Staff Initials: APPROVALS OR CORRECTIONS: Approved U Approved with Conditions TUES/THURS ROUTING: Please Route n Structural Review Required ❑ No further Review Required DUE DATE: 07 -10-08 DATE: DATE: Planning Division Permit Coordinator Not Applicable DUE DATE: 08 -07 -08 Not Approved (attach comments) n Permit Center Use Only • '. A CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Date: 7 / 1 / O B • City of Tukwila epaztment of CommunityDevelopment Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Plan Check/Permit Number: MO8 -177 ® Response to Incomplete Letter # 1 _ ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: WA STATE LIQUOR CONTROL BOARD Project Address: 14227 Tukwila International B1 Contact Person: Key Torre Phone Number: ZOC 1 —) q q Summary of Revision: Oft, 1 i'Y1 \ r// C# SA-vi s eti.4_ S o-E`f v4 1S' 6ECENED 0 OF TUKINILA IJUL 1 7 FENN CENTER 11; 4; Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision C � Received at the City of Tukwila Permit Center by: - ntered in Permits Plus on 7- t 1 - © b e / \applications \forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Name Role Effective Date Expiration Date EVERGREEN REFRIGERATION LLC PARTNER /MEMBER 12/22/2005 Bond Amount PATTON, DAVID PARTNER /MEMBER 01/06/2006 PATTON, RODGER PARTNER /MEMBER 01/06/2006 PATTON, MATTHEW PARTNER /MEMBER 01/06/2006 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date Untitled Page • Business Owner Information S Page 1 of 2 General /Specialty Contractor A business registered as a construction contractor with MI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. EVERGREEN REFRIGERATION LLC Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company EVERGREEN REFRIGERATION LLC 2067631744 727 S KENYON ST SEATTLE WA 98108 KING LIMITED LIABILITY COMPANY UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Separation Date Previous License Next License Associated License Specialty 1 Specialty 2 602512953 ACTIVE EVERGRL954R2 CONSTRUCTION CONTRACTOR 1/6/2006 1/6/2010 EVERGI*201 D7 GENERAL UNUSED Bond Information https: / /fortress.wa. gov /lni/bbip/Detail. aspx ?License= EVERGRL954R2 07/29/2008 SYMBOL LEGEND SYMBOL ABBV. DESCRIPTION E S.P. DUCT SECTION SUPPLY 11 Hp /A DUCT SECTION - RETURN /EXHAUST # TOTAL RECTANGULAR DUCT 7 INPUT OUTPUT AFUE ROUND DUCT PHASE EF 1 BROAN FLEXIBLE DUCT L MVD MANUAL VOLUME DAMPER 1 BDD BDD BACKDRAFT DAMPER 4 J � MD MOTORIZED DAMPER ( o /o) FD FIRE DAMPER Fuse (A) T FSD FIRE /SMOKE DAMPER (120V POWER REQ.) LBS 600 2.0 STD CEILING RADIATION DAMPER 10.1 150,000 �» SD SMOKE DETECTOR TO T THERMOSTAT 590 S SENSOR R R R REFRIGERANT LINES G G G NATURAL GAS LINES CEILING DIFFUSER (SUPPLY) J CEILING DIFFUSER (RETURN /EXHAUST) r4 EXHAUST FAN (CEILING MOUNTED) I INLINE FAN D8 PROPELLER - U FAN RECEIVED \ I / SIDEWALL DIFFUSER JUL 0 9 2008 L DUCT FITTING PERMIT CENTER B.D.J. 12' 2" f„ DATUM UNIT TAG a it DUCT RISER EXHAUST FAN SCHEDULE MARK MANF. MODEL CFM S.P. VOLTS PHASE Hp /A NOTES # TOTAL SEER EER INPUT OUTPUT AFUE VOLTS PHASE EF 1 BROAN QTR110 90 0.2" 115 1 71 W LOCATED ON CEILING MIN. OSA MOTOR DRIVE COOLING HEATING ELECTRICAL CFM HP # TOTAL SEER EER INPUT OUTPUT AFUE VOLTS PHASE M.C.A. Rec. Max UNIT ECON CURB TOTAL BTUH BTUH BTUH ( o /o) (V) (A) Fuse (A) LBS LBS LBS LBS 600 2.0 STD 94,910 10.1 150,000 121,500 81% 208 -230 30 37.8 60 590 36 115 741 1 cc 1 1 �1 U C DRAWING DATE: U 07 08 08 1.1 DWG. BY: GN CH K. BY: DP ,'= ,f JOB NO.: 80306 DWG. FILE: 80306M1 - SHEET: M 01 OF SHEETS HVAC COVER SHEET VICINITY MAP SCALE : NONE MARK RTU 1 MANE. AMERICAN STANDARD MODEL YSC090A TONS. 7.5 AIRFLOW CFM 3000 SP INS 0.5" NOTES: 1. THE ROOFTOP UNIT COMES COMPLETE WITH A SMOKE DETECTOR IN THE MAIN RETURN DUCT IN ACCORDANCE WITH IMC SEC.606. 2, THE ROOFTOP UNIT COMES COMPLETE WITH AN ECONOMIZER IN ACCORDANCE WITH THE WSEC SEC. 1423. GAS PACKAGE EQUIPMENT SCHEDULE SEPARATE PERMIT REQUIRED FOR: Mebhanical iectrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION COMPLETION AND COMMISSIONING FOR MECHANICAL SYSTEMS RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER WA ENERGY CODE (WSEC) SECTION 1416.1. AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER PER WSEC SECTION 1416.2.4.1 ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCE REPORT SHALL BE PROVIDED TO THE OWNER PER WSEC SECTION 14516.2.2.1. FOR WAREHOUSES SEMIHEATED SPACES AND SIMPLE SYSTEMS (AS DEFINED IN WSEC SECTION 142)): HVAC CONTROL SYSTEMS SHALL BE TESTS CALIBRATED AND ADJUSTED, SEQUENCES OF OPERATI SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORD WITH SPECIFICATIONS AND APPROVED PLANS, AND A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE FILED WITH THE OWNER PER WSEC SECTION 1416.2.3.2. FOR ALL OTHER SYSTEMS: HVAC CONTROL SYSTEMS SHALL BE TESTED, CALIBRATED AND ADJUSTED, SEQUENCES OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORD WITH SPECIFICATIONS AND APPROVED PLANS PER WSEC SECTION 1416.2.3.2; NECESSARY TESTS SHALL BE IDENTIFIED PER WSEC SECTION 1416.2.3; A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY PER WSEC SECTION 1416.2.5.1 AND A COMPLETE FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE FILED WITH THE OWNER PER WSEC SECTION 1416.2.5.2. FILTER SIZES NO. (LxWxD) 4NO. (16" x 25" x 2") REVISIONS No changes shall made to the scope of without a Building Division. r approval of Tukwila COTE: revisions will require a new plan submittal Lind may include addtional plan review fees. a FILE� Permit No. d ornl�icsns. plat review approval Is subject to n e f, $ � does not s'�utho��e an Approval of construction documents iPt the violation of any adopted code or ordinance. fl cei t or approved Flap Copy and conditions Is ae By Date: City of Tukwila la DIVISION NOTES 1,2 GENERAL NOTES DUCTWORK 1.1 ALL DUCT DIMENSIONS ON PLAN ARE CLEAR INSIDE DIMENSIONS, ADD 2" TO EACH DIMENSION TO OBTAIN OUTSIDE DIMENSION. ADD 4 "TO EACH DIMENSION IF DUCTWORK IS ON THE EXTERIOR OF BUILDING. 1,2 THE FIRST NUMBER ON ALL DUCT DIMENSIONS IS THE WIDTH AND THE SECOND NUMBER IS THE HEIGHT. 1.3 MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT RATING LESS THAN 50, PER IMC 602.2.1. 1.4 SEAL ALL TRANSVERSE JOINTS FOR DUCTWORK WITH STATIC PRESSURE BETWEEN 1/2 INCHES AND 2 INCHES. DUCTWORK WHICH IS DESIGNED TO OPERATE AT PRESSURES ABOVE 1/2 INCH WATER COLUMN STATIC PRESSURE SHALL BE SEALED IN ACCORDANCE WITH STANDARD RS -7. 1.5 ALL DUCT GAUGES PER SMACNA, IMC 603-4. 1.6 ALL DUCT SUPPORTS PER SMACNA, IMC 603 -10. 1.7 ATTACH DIFFUSERS AND GRILLES TO T -BAR GRID PER WA STATE & LOCAL CODES. 1.8 BALANCING DAMPERS ARE TO BE INSTALLED ON ALL BRANCH DUCTS OR DIFFUSERS. INSULATION 2.1 INSULATE OR LINE DUCTWORK PER WA. STATE ENERGY AND MECHANICAL CODES. 2.2 INSULATE REFRIGERANT & CONDENSATE PIPING PER STATE & LOCAL ENERGY CODES. GENERAL CONTRACTOR 3.1 GENERAL CONTRACTOR TO PROVIDE AND CUT OPENINGS FOR ALL ROOFTOP, CEILING, FLOOR, AND WALL PENETRATIONS, INCLUDING WEATHERPROOF SEALING AND FIRE PROOF LINING PER IMC & IBC. 3.2 GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATION AND DIMENSIONS WITH ERL BEFORE FRAMING OPENINGS. 3.3 GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING, AND PAINTING AS REQUIRED FOR MECHANICAL WORK. 3.4 GENERAL CONTRACTOR TO PROVIDE ADEQUATE STRUCTURAL SUPPORT AS REQUIRED FOR MECHANICAL WORK. 3.5 GENERAL CONTRACTOR TO PROVIDE ADEQUATE ENGINEERING AS REQUIRED FOR MECHANICAL WORK. 3.6 GENERAL CONTRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL MECHANICAL EQUIPMENT. 3.7 GENERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY ERL PROVIDE ALL CANT STRIPS AND CURB INSULATION, AND SEAL AGAINST LEAKS. 3.8 GENERAL CONTRACTOR TO PROVIDE ALL CUTTING AND PATCHING OF T -BAR CEILING AS REQUIRED FOR HVAC INSTALLATION. 3.9 GENERAL CONTRACTOR TO PROTECT ALL OPENINGS THROUGH FLOORS PROVIDED FOR DUCTWORK INSTALLATION IN ACCORDANCE WITH TABLE 601 OF INTERNATIONAL BUILDING CODE, WHERE REQUIRED BY SECTION 707 OF IBC. ELECTRICAL 4.1 ERL TO INSTALL ALL LOW VOLTAGE CONTROL WIRING, CONDUIT WILL BE PROVIDED BY ELECTRICAL CONTRACTOR, 4.2 ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL CONNECTIONS, DISCONNECTS, AND STARTERS FOR MECHANICAL EQUIPMENT. 4.3 ELECTRICAL CONTRACTOR TO VERIFY EQUIPMENT SIZES, LOADS AND LOCATIONS WITH ERL MECHANICAL PLAN AND WITH FIELD CONDITIONS. 4.4 ELECTRICAL CONTRACTOR TO INTERLOCK BATHROOM EXHAUST FANS WITH LIGHT SWITCH. 4.5 ERL TO PROVIDE 7 -DAY NIGHT SETBACK, PROGRAMMABLE TYPE T -STAT WITH CAPABILITY OF 5 °F DEADBAND. 4.6 ERL TO VERIFY FINAL LOCATION OF THERMOSTAT WITH CUSTOMER. 4.7 ELECTRICAL CONTRACTOR TO PROVIDE ELECTRICAL GCFI OUTLET WITHIN 25 FT OF EACH PIECE OF MECHANICAL EQUIPMENT. PLUMBING 5.1 PLUMBING CONTRACTOR TO FURNISH AND INSTALL ALL GAS PIPING FOR MECHANICAL EQUIPMENT PER CODE. 5.2 PLUMBING CONTRACTOR OFFSET VENTS 10 FEET MINIMUM FROM ALL HVAC FRESH AIR INTAKES OR 2' ABOVE HIGHEST POINT OF INTAKE, IMC 401.5.1. 5.3 CONDENSATE DRAINS FROM RTU BY ERI TO DRAIN WITHIN 12" OF UNIT. CONDENSATE DRAINS FOR AIR HANDLERS BY PLUMBER. ENERGY CODE COMPLIANCE 6.1 AT A MINIMUM, EACH FLOOR IS TO BE CONSIDERED A SEPARATE ZONE. VERIFY THERMOSTATIC CONTROL FOR EACH ZONE AS INDICATED ON PLANS. 6.2 OUTSIDE AIR INTAKES, EXHAUST OUTLETS, AND RELIEF OUTLETS SERVING CONDITIONED SPACES SHALL BE EQUIPPED WITH DAMPERS WHICH CLOSE AUTOMATICALLY WHEN THE SYSTEM IS OFF OR UPON POWER FAILURE, PER WE'EC SEC. 141 2.4.1. 6.3 AIR ECONOMIZERS WHERE REQUIRED BY CODE ARE INDICATED BY THE EQUIPMENT SCHED`. !LE AT 1;10% CAPABILITY, CONTROL AND OPERATION OF THE ECONOMIZER SHALL COMPLY WITH WSEC SEC. 1423. MECHANICAL CODE COMPLIANCE 7.1 WHERE REQUIRED PROVIDE AUTOMATIC SHUTOFF ACTIVATED BY SMOKE DETECTORS IN EACI I SYSTEM DELIVERING HEATING OR COOLING AIR IN EXCESS OF 2000 CFM. DETECTORS SHALL BE LOCATED IN THE MAIN RETURN AIR PER IMC 606. 4■ 4 rN 0 :F•1;' w 415 w w w w 0 eC L1 NOT PUBLISHED. ALL RIGHTS RESERVED, THE DRAWING AND SPECIFICATIONS. IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF EVE- RGREEN REFRIGERATION INC. NU PART THEREOF SHALL BE REPRODUCED, COPIED, ADAPTED, DISC- LOSED OR DISTRIBUTED TO OTHERS, SOLD, PUB- LISHED OR OTHERWISE USED WITHOUT THE PRIOR WRITTEN CONSENT OF AND APPROPRIATE COMPEN- SATION TO EVERGREEN REFRIGERATION INC. VISUAL CONTACT WITH THE ABOVE DRAWINGS OR SPECIFIC- ATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. I C NO DATE ITEM ) .I ) Ll 5 - --.� -- � DRAWING DATE: Lu Gj DWG. BY: GN CHK. BY: DP JOB NO.: 80306 DWG. FILE: 80306M2— 2 SHEET: 2 OF 2 SHEETS El DR,GS SUITE "A" 15066 SF p p p NO WORK TO BE DONE IN THIS SUITE LA,\D EXIST EXIT V SUITE "B" 3714 SF OCCUPANCY 37 (ONE EXIT ALLOWED) SCALE : 1/8" r AT HVAC FLOOR PLAN 350 CFM 10" /( 1F) / 400 CFM 375 CFM DROPS FROM EXISTING 7.5 TON UNIT 10" 375 CFM 10 375 CFM 350 CFM RETAIN E 10" 14" XIS SUSP. CEILING 16 400 CFM 16" 10" 375 CFM 375 CFM RETAIL SHELL SUITE "C" 5000 SF 16" 375 CFM 18" 12" 350 CFM 350 CFM VI D 0 NO WORK TO BE DONE IN THIS SUITE -0 PH \TAB. SUITE "D' 5593 SF °RAGE 3480 SF REVIEWED FOR CODE COMPLIANCE ' APPROVED JUL 2 2118 City Of Tukwila BUILDING i t'lO8-- l77 RECEW D JUL 0 92009 PERMIT DENT EN i 0) co U Cp 4 cfl co es C"3 Q 41; (] s-J NOT PUBLISHED. ALL RIGHTS RESERVED. THE DRAWING AND SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY or EVE- RGREEN REFRIGERATION INC. NO PART THEREOF SHALL BE REPRODUCED, COPIED, ADAPTED, DISC- LOSED OR DISTRIBUTED TO OTHERS, SOLD, PUB- LISHED OR OTHERWISE USED WITHOUT THE PRIOR WRITTEN CONSENT OF AND APPROPRIATE COMPEN- SATION TO EVERGREEN REFRIGERATION INC. VISUAL CONTACT WITH THE ABOVE DRAWINGS OR SPECIFIC- ATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. W op CD ti CD iw 6.3 0 0 0 ❑ ❑ PROGRESS PRINTS - NOT FOR CONSTRUCTION APPROVED FINAL DRAWINGS CONSTRUCTION DRAWINGS AS BUILT DRAWINGS