Permit M08-188 - WESTFIELD SOUTHCENTER MALL - MARC ECKO CUT & SEW
MARC ECKO CUT & SEW 837 SOUTHCENTER MALL M08-188 Parcel No.: 6364200010 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Value of Mechanical: $30,000.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic C o mme rcial/Indust rial doc: IMC -10/06 Cityrf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 837 SOUTHCENTER MALL TUKW MARC ECHO CUT & SEW 837 SOUTHCENTER MALL , TUKWILA WA WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD CA Contact Person: Name: KEVIN WENDELL Address: 100 EAST SWISSVALE AV , PITTSBURG PA Contractor: Name: SOUND HEATING & A/C INC Address: 5209 122 ST E , TACOMA, WA Contractor License No: SOUNDHA066BM MECHANICAL PERMIT DESCRIPTION OF WORK: MECHANICAL FOR NEW TI: ADDITION OF VAV BOX AND RELATED DUCTWORK TO COMPLETE HVAC SYSTEM WITHIN SPACE. EQUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 0 0 0 0 0 0 0 0 * *continued on next page ** Permit Number: Issue Date: Permit Expires On: M08 -188 08/18/2008 02/14/2009 Phone: Phone: 412 243 -3430 X 236 Phone: 253- 535 -6249 Expiration Date: 08/15/2009 Fees Collected: $507.50 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 14 Diffuser 12 Thermostat 1 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment M08 -188 Printed: 08-18 -2008 Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie • with, whether specified herein or not. The granting of this �aiit do Win• presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction o Signature. doc: IMC -10/06 Print Name: lil 4� • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Date: 6-(9 V o k. I am authorized to sign and obtain this mechanical permit. Permit Number: M08 -188 Issue Date: 08/18/2008 Permit Expires On: 02/14/2009 Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M08 -188 Printed: 08-18 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 837 SOUTHCENTER MALL TUKW MARC ECHO CUT & SEW 1: ** *BUILDING DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: ** *FIRE DEPARTMENT CONDITIONS * ** M08 -188 ISSUED 07/18/2008 08/18/2008 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 13: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 14: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 15: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) doc: Cond -10/06 M08 -188 Printed: 08 -18 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 17: Local U.L. central station supervision is required. (City Ordinance #2051) 18: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 19: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 20: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 21: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 22: These plans were reviewed by Inspector 0700. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** M08 -188 Printed: 08 -18 -2008 I hereby certify that I have this work will be complied The granting of this pe t construction or the pe Signature: Print Name: doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us read these conditions and will comply with them as outlined. All provisions of law and with, whether specified herein or not. does not presume to give authority to violate or cancel the provision of any other work l ance of ork. M08 -188 Date: ordinances governing or local laws regulating Printed: 08-18 -2008 Site Address: Company Name: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila. Tenant Name: MA C- CC - 4 0 C Li r k 5e-Lt..) Property Owners Name: (i1 t S T r EL CO ('� t'c'�P�1�' Mailing Address: 1160 ( u1/4/1 Hike Y OkLeV'k -A0 E -Mail Address: A//4 Contact Person: E -Mail Address: Contractor Registration Number: Company Name: CoCI -ri A tv o 6(6.- et- ij Mailing Address: 7 l Contact Person: C-cf S t1& i'l` i Company Name: HAIL lY F : ►L (r! � i l (L (�+` (a` Mailing Address: 17 50 C,O Yh ►'►T E g...ce. G 0 b> 1&1 Contact Person: KC 1) 5 tJ ek IZC E -Mail Address: IS5 k) k H.4Li.a i;Q6'C11& tit Ei�KI .tit; - • co to Q AApplications'Fomis- Applications On Line'3 -2006 - Remit Application.doc Revised: 9 -2006 bh c I r CC-1 d Building Permit No. 1VMecltanieal Pmt 1 To.. Plumbing /Gas Permit N o Pu blic Works °Pe rmitt No. P roject N o, Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: 6. 3 4Z0 00 ( 0 Suite Number: * Floor: i New Tenant: Yes ❑ .. No is An'c .i> City G4 I M ) 2 ^S State Zip CONTACT PE y:to be i Name: KLt/t tij v" No t. p + --sir. t 61-4,A1S Y 1 Rai 4G - lxE - A)r Day Telephone: +0- -3#3O it 6 Mailing Address: We e E s . T l,,r i SS o L.C" if a it a E -Mail Address: C t Oe - 1_AMi6 ()C'': Le" +I1 Pi /psis ►ti",,G' H Pao City State Zip Fax Number: !t x- 3 "71 S S3 GE TIARA (Contractor ONTRACTOR INFORMATION ltit€an for 11+Y.eciiaitical (lad 4) for Plumbing and Mailing Address: City Day Telephone: Fax Number: CI-1A% 6-TO ty City Day Telephone: 4 6 17 Fax Number: S 1 wore- 13Gi4f` L-4 E, city Day Telephone: GS 1' Fax Number: C. 51 State Zip Expiration Date: TX 7‘02... State o Zip - 635- 5693 NI Ai 'i 5i1 t,? state Zip -74-' - lt0O -74 " 370 Page 1 of 6 BUILDING PERMIT INFORMATION - 206 -431 -3670 Valuation of Project (contractor's bid price): $ 5, . 0 O(✓ Existing Building Valuation: $ 2-3 5 t`'a" 'a ( curia Scope of Work (please provide detailed information): 1 're a.tO . " tGIiT.1 >✓ T Fi T Oi'T c.6 A .1 ( D%rniSED 1.t1 R ,4 ec:r 1on1 Ur Rk) W+4LL CO PS - r(LkCT(UA1 OF rsel.L' 57e01 F1Z T f IZr/ D601 G-7t 30 Ao of rloiu ti Auld► -,} 4' F • ; t ill v t 1: o r(Ai c ylle " ('> Ai vi°rvi,A.T1 1`k GF 4VcD Will there be new rack storage? Yes J. No If yes, a separate permit and plan submittal will be required. 1° Floor Floors Accesso Attached Ott covered Deck rovide All Building Areas in Square Footage Below Addition ti Existing tructure PLANNING DIVISION: 4/ Single family building footprint ea of the foundation of all structures, plus any decks over 18 inches *For an Accessory dwelling, p vide the following: Lot Area (sq ft): Floor area of principal dwelling: Type o Occupancy per I13C M nd overhangs greater than 18 inches) Floor area of accessory dwelling: *Provide docume . ion that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Sta . Provided: Standard: Compact: Handicap: Will there be a chan in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: Sprinklers �] Automatic Fire Alarm ❑ None Q :,ApplicationsVFomts- Applications On Linek3 -2006 - Permit Application.doc Revised: 9 -2006 bh ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ,( No If 'yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 4 4 ❑ On -site Septic System — For on -site septic system. provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM 0 Fire Damper 1 4 . 0 -3 HP /100,000 BTU o Furnace >100K BTU C Evaporator Cooler C Diffuser ( 2, 3 -15 HP /500,000 BTU U Floor Furnace 0 Ventilation Fan Connected to Single Duct 0 Thermostat 1 15 -30 HP /1,000,000 BTU 0 Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct U Emergency Generator 50+ HP/1,750,000 BTU Repair or Addition to Heat/Refrig /Cooling System 0 Incinerator - Domestic 0 Other Mechanical Equipment Air Handling Unit <10.000 CFM Incinerator — Comm/Ind tql V ,3e) k (Al :: LGcri j ' 4 r 1 MECHANICAL PERMIT INFORMATION 206 -431 -3670 MECHANICAL CONTRACTOR INFORMATION 'L L ) Company Name: Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $ 3 C' oc% Scope of Work (please provide detailed information): ('ti - 11 - =-V--ICI '� rG /L i i ( IT C' i~ or Pr rs tr w (.. O ✓h IS t ij 5 f'1 C c) Aa EXIST/ Ai - its r& (,g 1400i - riot (F V4v .$C ANb RED.- 4T e: - 0 we Kg, to compL&Te; kiv..4 c- 5/ i,% 17/-1 iv 5P/1-C -C Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ® Replacement .... ❑ City Day Telephone: Fax Number: State Zip Fuel Type: Electric In Gas ....❑ Other: Indicate type of mechanical work being installed and the quantity below: Q: Applications \Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 lab Page 4 of 6 Fixture Type: Qty " Fixture Type: j Fixture Type: Q'ty Fixture Type: Qty Bathtub or combination bath/shower U Drinking fountain . 'at cooler (per head Wash fountain Gas piping outlets 0 Bidet C) commercial gr. : er, commercial 3 Receptor, indirect waste Clothes washer, domestic 0 Floor dra Sinks 0 Dental unit, cuspidor 0 Showe ingle head trap 0 Urinals 0 Dishwasher, domestic, with independent drain Lava i Water Closet Building sewer or trailer park sewer : " n water system — per .rain (inside building) © er heater and /or vent i Additional medical gas inlets /outlets — six or more 0 Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors s .3 Repair or alteration of water piping and/or water treating equipment Repai .r alteration of drain. *e or vent piping 0 Medical gas piping system serving one to five inlets /outlets for specific gas C5 I PLUMBING AND GAS PIPING PERMIT INFORMATION — 206- 431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: " � (j 0 Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: Valuation of Plitt bing work (contractor's bid price): $ 2. / Cttoo Valuation of Gas Pi ng work (contractor's bid price): $ u / 4k City Day Telephone: Fax Number: Expiration Date: State Zip Scope of Work (please ovide detailed information): I i 60- rte 144 r t* F „„). Oe": rn ISCP SP#1L Ni 1 4 Ni IA) e* cnov t, Tt' R!o r'l�t,�ftr Building Use (per Int'l Building Cod P' CRC_A v7 LC- Occupancy (per Int'1 Building Code): oe-Ci. _ LC *l Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas pipin Q: ApplicationsTorms- Applications On Line3-2006 - Permit Application.doe Revised: 9 -2006 hh utl being installed and the quantity below: Page 5 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER .9R AUTI !ZED AGENT: Signature:. Print Name: Uj L° CU Mailing Address: GFt ' 7 S Lv 1 55 ir,' Lt E VC Date Application Accepted: 611 lo) Q: ApplicationsWorms- Applications On Line'3 -2006 - Permit Application.doc Revised: 9 -2006 bh r Date Application Expires: Date: a 7 (f/Cl Day Telephone: k 2 .43 . 3 #3 u x 236 Tl Li City tilts 101 State Staff Initials: Zip Page 6 of 6 Parcel No.: 6364200010 Address: Suite No: Applicant: MARC ECHO CUT & SEW Receipt No.: R08 -03159 Initials: LAW User ID: 1632 Payee: TRANSACTION LIST: Type Method dor.: Ranpint -OR 837 SOUTHCENTER MALL TUKW Payment Check City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us Descriptio 041535 ACCOUNT ITEM LIST: Description Account Code RECEIPT SOUND HEATING AND AIR CONDITIONING INC Amount 60.00 MECHANICAL - NONRES 000.322.102.00.0 Permit Number: Status: Applied Date: Issue Date: Payment Amount: $60.00 Payment Date: 09/05/2008 02:55 PM Balance: $0.00 Current Pmts 60.00 Total: $60.00 M08 -188 ISSUED 07/18/2008 08/18/2008 7051 09/05 9707 TOTAL 60.00 Printp(i ns-n5 -2nnR Receipt No.: R08 -02976 Initials: WER User ID: 1655 Payee: SOUND HEATING & A/C ACCOUNT ITEM LIST: Description rtnr.! Raraint -(16 MECHANICAL - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: M08 -188 Address: 837 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 07/18/2008 Applicant: MARC ECHO CUT & SEW Issue Date: TRANSACTION LIST: Type Method Descriptio Amount Payment Check 041426 406.00 Account Code Current Pmts 000.322.102.00.0 406.00 Total: $406.00 Payment Amount: $406.00 Payment Date: 08/18/2008 01:23 PM Balance: $0.00 6253 08/18 9710 TOTAL 406.00 Printari: f1R -1 R.7(1f1R RECEIPT NO: R08 -02638 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us Initials: JEM Payment Date: 07/18/2008 User ID: 1165 Payee: LAMI GRUBB MANAGEMENT SERVICES, INC. SET ID: S000001081 SET TRANSACTIONS: Set Member Amount D08 -379 1,163.83 EL08 -1015 94.21 erT88< 101.50 PG08 -209 29.00 TOTAL: 1,388.54 Payment Check 0688 ACCOUNT ITEM LIST: Description ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES SET RECEIPT TOTAL: Total Payment: 1,388.54 SET NAME: Tmp set/Initialized Activities TRANSACTION LIST: Type Method Description Amount 1,388.54 1,388.54 Account Code Current Pmts 000.345.832.00.0 94.21 000/345.830 1,294.33 TOTAL: 1,388.54 3 07/10 9716 TOTAL 1388=54 Project: pi» / . Peep Type of Inspection: Swr h l4_ F - (tiff- bcbJ& Address: 937 mi9/ Date Called: Special Instructions: Date Wanted: 0 •: 5 -- Z„Z- 1J a.m. p.m. Requester: Phone No: INSPECT • N NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION E 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 © Approved per applicable codes. El Corrections required prior to approval. COMMENTS: 5mage sf1rn`- �,aciz)_ oik.& 7Pc,n f ('gy iF ,j, E ctor: REINSPECTION FE = REQ (RED. Prior to inspection, fee must be t 6300 Southcenter = lvd., Suite 100. Call to schedule reinspection. Rec - • t No.: Date: COMMENTS: Type of Inspectio j -, 7' ‘Ccr". ``� t /U ---. rb 0 0 S ice j 1,34. w. I( . /.1 - f rC - - -s c.a-c- vLJC Special Instructions: / Date Wanted: i y 1 )..r " n1 p.m. Requester: Phone No 2 5 3 - 6'75 .- - 33 re) - , 1 1 Project: ,M nr(� F Ev Type of Inspectio j -, 7' ‘Ccr". ``/ Address S c ., . -4,4 Date Called: Special Instructions: / Date Wanted: i y 1 )..r " n1 p.m. Requester: Phone No 2 5 3 - 6'75 .- - 33 re) sir INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION v 6300 Southcenter Blvd.; #100, Tukwila, WA 98188 (206)431 -36 Approved per applicable codes. Inspector: ftici SS" Corrections required prior to approval. 1 Date: ( 7 / r o Cr ri $60.00 REINSPECTION FEE R$QUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: COMMENTS: Type of Inspection: \.®, sA, ,; ke 4 ar<,Pc . rix-r\-5 Ai 1) „ ,) A-2-1--; , A r uo ALIfe_ ( c„ T 0 0 I • _ Date Wanted: I ' J . p.m. 1 ? -'. - S , .1, cj "t- ( C 71)! apjAt Requester: Phone No: /1 �, 7 c3 - E - - Project: Nk Au ,i` P r Ku Type of Inspection: \.®, sA, ,; ke 4 ar<,Pc Address: Date Called: Special Instructions: n 7 3 _ Date Wanted: I ' J . p.m. 0 7 .- ( S L- Requester: Phone No: /1 �, 7 c3 - E - - 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION P 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 7 itk o 2( - i Corrections required prior to approval. Date: c • ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Project: „oce id4eO (' 2,/ Type of Inspection: �i.t. 1 / Ad rd e : J 7 m,4 7 Date Called: • Special Instructions: Date Wanted: a.m Requester: Phone No: c25 3 5°6" -52 7 • . rive /Pc °, INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 J Approved per applicable codes. Corrections required prior to approval.. I JQ COMMENTS: r 5 dl1S'A2r/- Ins Dat F j la n $6 REINSPECTION FEE REQU RED Prior to inspection, fee must be pa ' • t 6300 Southcenter Blvd., S ite 1 O. Call to schedule reinspection. Receipt No.: 'Date: COMMENTS: , ��a F !''..r -' JL 4- _,l Date Called: '' AC ..sLi e 5A4 d l�--e —5 9-- w 7\ w < rig Kr t c o et A✓ 1-.. - ' • 6 a . ( kv & D Ar 1, Project: Type of Inspection: Address: �� 3 r ( .I . C_, 1-01 r' Date Called: '' Special Instructions: / • Date Wanted: / � � rr - . ��U p.m. Requester: Phone ; n ? s 3 -- r'7s - 33.x ° S INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION r I�- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Approved per applicable codes. • Corrections required prior to approval. Inspec or: 'l t Date - C El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: COMMENTS:` CilfO!/ T � /r0 Inspection: it 70/ Ad ress: ��� \ 1 1..-t X - 0 /0 4 r / j.P//�l :. • A -v de... J". .! / •-- p l rr ��� a 4 " G " ..9e . 7 f, ,;■•■ v l i, s7 4— ,-.. l7 ��`, r fry ;" r /,,97-3— ri a r .. . TG C hi/A. 7 H 7 /I 4 2 ,frp :. • i . 1 Al Pro / F CilfO!/ T � /r0 Inspection: it 70/ Ad ress: ��� ��q�� Date Call Special Instructions: Date Wanted: n� �J (—a -rrl- p.m. Requester: Phone No. 26"3 / 75-33$ ;" INSPECTION RECORD Retain a copy with permit INSPECTION NO. - PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 7 0 Approved per applicable codes. orrections required prior to approval. /0 ID $60.00 REINSPECyi . N FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: N I nspectio n: Spd: Fire Alarm: & Monitor: r: ts: Ck upenc T yper Special. Instructions: Heating Equipment Schedule Equip. ID Brand Name' Model No.' Capacity Btu /h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency VAV -1 Titus DTQP (Electric coil) 34120 -10k1 2150 650 - - - RECEIVED CITY OF TUKWRA JUL 18 2008 PCRMIT CENTER al. K Cooling Equipment Schedule Equip. ID Brand Name' Model No.' Capacity Btu/h Total CFM OSA CFM or Econo? SEER or EER IPLV Location VAV -1 Titus DTQP 60000 2150 650 - - M1 al. K x ■ r t Fan Equipment Schedule Equip. ID Brand Name' Model No.' CFM SP' HP /BHP Flow Control Location of Service Applicant Phone: al. K x ■ r t Project Info Project Address &Slam Southcenter Rai/away Date 7/11/2008 014.11 Tukwila, WA 98188 For Building Dept. Use REVIEWED FOJ CODE COMPLIAN pp Applicant Name: �r — L _ CIA y SCAd Applicant Address: Sl % wi o 4,4410,0,4,01/..... Applicant Phone: 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Summary MECH -SUM 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Description Briefly describe mechanical system type and features. Includes Plans FILE COPY Pr rmIt No. Drawings must contain notes requireing compliance with commissioning requi JUL 2 8 2008 C Of Tukwila e II®IVISIC Compliance Option Simple System 0 Complex System O Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. 'If available. 2 As tested according to Table 14 -1A through 14 -1G. 3 If required. ° COP, HSPF Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). CE Mechanical - Complex Systems Checklist MECH -COMP 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address 633 Southcenter Parkway Date 7/11/2008 The following additional information is necessary to check a mechanical permit application for a complex mechanical system for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Use the checklist as a reference for notes added to the mechanical drawings (see the MECH -CHK checklist for additional system requirements). This information must be on the plans since this is the official record of the permit. Having this information in separate specifications alone is NOT an acceptable alternative. For Building Department Use Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes ADDITIONAL CHECKLIST ITEMS FOR COMPLEX SYSTEMS ONLY n.a. 1431.1 Field assem. sys. Provide calculations n.a. 1432.1 Setback & shut -off Indicate separate systems or show isolation devices on plans n.a. 1432.2.1 Air system reset Indicate automatic reset n.a. 1432.2.2 Hydronic System Indicate automatic reset, cooling tower, & heat pump loop valves n.a. 1433 Air Economizer Indicate economizer on equipment schedule or provide calculations to justify exemption and demonstrate 10% higher efficiency for equipment with out economizer. n.a. 1433 Water Economizer Indicate water economizer and provide calculations if 1433 Exception 2 is utilized n.a. 1434 Separate air sys. Indicate separate systems on plans n.a. 1435 Simul. htg. & clg. Indicate that simultaneous heating and cooling is prohibited, unless use of exception is justified n.a. 1436 Heat recovery Indicate heat recovery on plans; complete and attach heat recovery calculations n.a. 1437 Elec. motor effic. MECH -MOT or Equip. Schedule with hp, rpm, efficiency n.a. 1438 Variable flow sys. Indicate variable flow on fan and pump schedules n.a. 1439.1 Kitchen Hoods Indicate uncooled and unheated make -up air n.a. 1439.2 Fume Hoods Indicate VAV, unheated/uncooled or heat rec. makeup no is circled for any question, provide explanation: Decision Flowchart Use this flowchart to determine how the requirements of the Complex Systems Option apply to the project. Refer to the indicated Code sections for more complete information on the requirements. Start Here Section 1411.1 Equipmen Efficiency Shall Meet Tables 14 -1A through 14 -1G 2006 Washington State Nonresidential Energy Code Compliance Form es/Oil Furnac input > 225.000 tuh or Gas/0 't Heat ny Fuel Furnac input> 225.000 Btuh? Air System Serving Multiple Zones? pacity of H Heating System > 00,000 Btuh? Yes 1411.1 Intermittent Ignition Device & Power Venting or Damper. If input 225,000 Btuh then 1412.6 Modulating or Staged Combustion Controls Required Yes 4 1411.1 0.75% Maximum Jacket Loss Yes Section 1431.1 Calculations of Total On -Site Energy Input & Ouput Required (continued on back) Yes Section 1432.2.1 Supply Air Reset Controls Required Yes No Section 1432.2.2 Hot Water Supply Temperature Reset Required Mechanical Permit Plans Checklist MECH -CHK 2008 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address 633 Southcenter Parkway 'Date 7/11/2008 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability PP tY (yes, no, n.a.) Code Section Component I ,Information Required Location on Plans Building De 9 artment P Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance n.a. 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule yes 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency Mi n. a. 1411.1 Combustion htg. Indicate intermittent ignition, flue/draft damper & jacket loss 1412 HVAC controls yes 1412.1 Temperature zones Indicate locations on plans M1 yes 1412.2 Deadband control Indicate 5 degree deadband minimum M3 n -a- 1412.3 Humidity control Indicate humidistat n. a. 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types n. a . 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage n.a. 1412.4.2 Optimum Start Indicate optimum start controls n. a. 1412.5 Heat pump control Indicate microprocessor on thermostat schedule n. a • 1412.6 Combustion htg. Indicate modulating or staged control n -a- 1412.7 Balancing Indicate balancing features on plans 1412.8 Ventilation Control Indicate demand control ventilation for high- occupancy areas n. a . 1422 Thermostat interlock Indicate thermostat interlock on plans n. a . 1423 Economizers Equipment schedule 1413 Air economizers n. a. 1413.1 Air Econo Operation Indicate 100% capability on schedule n.a. 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb n -a. 1413.2 Water Econo Doc Indicate clg load & water econoe & clg tower performance n. a. 1413.3 Integrated operation Indicate capability for partial cooling n.a. 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems yes 1414.1 Duct sealing Indicate sealing necessary M3 yes 1414.2 Duct insulation Indicate R -value of insulation on duct M3 yes 1415.1 Piping insulation Indicate R -value of insulation on piping M3 1416 Completion Requirements n.a. 1416.2.1 Commissioning Provide commissioning plan M3 yes 1416.2.2 -3 Sys.Bal & Func.Test Indicate air and water system balancing & functional testing n. a. 1416.2.4 Commissioning Indicate O &M manuals, record drawings, staff training n.a. 1416.2.5 Comm. Report Indicate requirements for prelim. & final commissioning report n. a. 1434 Separate air sys. Indicate separate systems on plans Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. yes 1441 Elec. water heater Indicate R -10 insulation under tank M3 yes 1442 Shut -off controls Indicate automatic shut -off M3 yes 1443 Pipe Insulation Indicate R -value of insulation on piping M3 n. a. 1452 Heat Pump COP Indicate minimum COP of 4.0 yes 1452 Heater Efficiency Indicate pool heater efficiency 0. a. 1453 Pool heater controls Indicate switch and 65 degree control n. a. 1454 Pool covers Indicate vapor retardant cover 0. a . 1454 Pools 90+ degrees Indicate R -12 pool cover 2006 Washington State Nonresidential Energy Code Compliance Form ACTIVITY NUMBER: M08 -188 DATE: 07 -18 -08 PROJECT NAME: MARC ECKO CUT & SEW SITE ADDRESS: 837 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: g'D!vi i el n ' Public Works Complete Comments: Documents/routing slip.doc 2 -28 -02 PERMIT COORD COPY 41 PLAN REVIEW /ROUTING SLIP 0 APPROVALS OR CORRECTIONS: p lop i C ire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete n TUES/THURS ROUT NG: Please Route Structural Review Required REVIEWER'S INITIALS: n DATE: DATE: Planning Division Permit Coordinator DUE DATE: 07-22-08 Not Applicable n Permit Center Use Only . ' ' ' ' INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required Approved 0 Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: n n n DUE DATE: 08-19-08 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: • Name Role Effective Date Expiration Date HOOD, CURTIS C Cancel Date 01/01/1980 Bond Amount HOOD, RANDY A 5 01/01/1980 SC2727 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 CBIC SC2727 08/03/2001 Until Cancelled $6,000.0007/10/2001 4 CBIC SC2727 08/14/199908/03 /2001 $4,000.00 3 UNITEDF PACIFIC INS CO 6158416 08/14/1998 Until Cancelled 01/07/2000 $4,000.00 2 UNITED PACIFIC INS U6158416 08/14/199408/14 /1998 $4,000.00 Untitled Page General /Specialty Contractor A business registered as a construction contractor with Lftl to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. SOUND HEATING Et A/C INC Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company SOUND HEATING a A/C INC 2538753350 5526 184TH STREET E PUYALLUP WA 98375 PIERCE CORPORATION UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Separation Date Previous License Next License Associated License Specialty 1 Specialty 2 601479795 ACTIVE SOUNDHA066BM CONSTRUCTION CONTRACTOR 1/14/1994 8/15/2009 SOUNDHC112N2 HTG /VENT /AIR CONDITIONING UNUSED Business Owner Information Bond Information • Page 1 of 2 https: // fortress. wa. gov /lni/bbip/Detail.aspx ?License= SOUNDHA066BM 08/18/2008 ABBREVIATIONS AC AFF AMP AP BTU CBV CFH CFM CHW CHWR CHWS CLG CO CR CW DB DEMO DIA DIFF DWG DX EAT ELEC ELEV EMS ESP EWB EWT EX H EXIST F FSD FCO FD FD FDC FFE FLR F GA GAL GC HP HT HVAC HW HZ ID INV KW LAT ACCU AH U AH UP BP CDWP CEF CHWP CP CPR CRP CUH DHC ECH EF EHC ES EUH EWC EWH FCU FPB AIR CONDITION ( —ING, —ED) ABOVE FINISHED FLOOR AMPERE (AMP, AMPS) ACCESS PANEL BRITISH THERMAL UNIT CIRCUIT BALANCING VALVE CUBIC FEET PER HOUR CUBIC FEET PER MINUTE CIRCULATING HOT WATER CHILLED WATER RETURN CHILLED WATER SUPPLY CEILING CLEANOUT CONDENSATE RETURN COLD WATER DECIBEL DEMOLITION DIAMETER DIFFUSER DRAWING DIRECT EXPANSION ENTERING AIR TEMPERATURE ELECTRICAL ELEVATION ENERGY MANAGEMENT SYSTEM EXTERNAL STATIC PRESSURE ENTERING WET BULB ENTERING WATER TEMPERATURE EXHAUST EXISTING FAHRENHEIT COMBINATION FIRE /SMOKE DAMPER FLOOR CLEANOUT FIRE DAMPER FLOOR DRAIN FIRE DEPARTMENT CONNECTION FINISHED FLOOR ELEVATION FLOOR FEET PER MINUTE FOOT OR FEET GAGE OR GAUGE GALLONS GENERAL CONTRACTOR GALLONS PER HOUR HORSEPOWER HEIGHT HEATING, VENTILATING, AIR CONDITIONING HOT WATER HERTZ INSIDE DIAMETER INVERT KILOWATT LEAVING AIR TEMPERATURE AIR COOLED CONDENSING UNIT AIR HANDLING UNIT AIR HANDLING UNIT PUMP BOOSTER PUMP CONDENSER WATER PUMP CEILING EXHAUST FAN CHILLED WATER PUMP CIRCULATING PUMP CONDENSATE PUMP AND RECEIVER CONDENSATE RETURN PUMP CABINET UNIT HEATER DUCT HEATING COIL ELECTRIC CABINET HEATER EXHAUST FAN ELECTRIC HEATING COIL ELECTRONIC SENSOR ELECTRIC UNIT HEATER ELECTRIC WATER COOLER ELECTRIC WATER HEATER FAN COIL UNIT FAN POWERED VARIABLE AIR VOLUME LBS LWB LWT MA MAX MBH MIN MISC NA NC NIC NTS OA OBD ORD PH RA RD REC REL RH RM RPM SA SAN SD SF SP SPEC ST STD TD TSP V P VFD VSD VOL VTR W/ W/o WC WCO WT EQUIPMENT TAGS POUNDS LEAVING WET BULB LEAVING WATER TEMPERATURE MIXED AIR MAXIMUM THOUSAND BTU'S /HR MINIMUM MISCELLANEOUS NOT APPLICABLE NOISE CRITERIA NOT IN CONTRACT NOT TO SCALE OUTSIDE AIR OPPOSED BLADE DAMPER OVERFLOW ROOF DRAIN PHASE (ELECTRICAL POLYVINYL CHLORIDE RETURN AIR ROOF DRAIN RECESSED RELIEF RELATIVE HUMIDITY ROOM REVOLUTIONS PER MINUTE SUPPLY AIR SANITARY SMOKE DAMPER SQUARE FEET STATIC PRESSURE SPECIFICATION STORM STANDARD TEMPERATURE DIFFERENCE TOTAL STATIC PRESSURE TYPICAL VOLTS VARIABLE FREQUENCY DRIVE VARIABLE SPEED DRIVE VOLUME VENT THROUGH ROOF WATTS WITH WITHOUT WATER CLOSET WALL CLEANOUT WEIGHT GWH HU HUH HWP IH MAU PCWP PHWP PRV REF RF RH RTU SCWP SEP SHWP SP TF USF BOX VAV WS GAS WATER HEATER HUMIDIFIER HORIZONTAL UNIT HEATER HEATING WATER PUMP INTAKE HOOD MAKE—UP AIR UNIT PRIMARY CHILLED WATER PUMP PRIMARY HEATING WATER PUMP POWER ROOF VENTILATOR RELIEF EXHAUST FAN RETURN FAN RELIEF HOOD ROOFTOP UNIT SECONDARY CHILLED WATER PUMP SEWAGE EJECTOR PUMP SECONDARY HEATING WATER PUMP SUMP PUMP TRANSFER FAN UTILITY SET FAN VARIABLE AIR VOLUME BOX VERTICAL UNIT HEATER WATER SOFTENER HVAC SYMBOL LEGEND DUCTWORK SUPPLY DUCT UP SUPPLY DUCT DOWN SUPPLY DUCT UP THROUGH ROOF RETURN /EXHAUST /RELIEF DUCT UP RETURN /EXHAUST /RELIEF DUCT DOWN RETURN /EXHAUST /RELIEF DUCT UP THROUGH ROOF MANUAL VOLUME DAMPER MOTORIZED DAMPER FIRE DAMPER W /ACCESS PANEL FIRE /SMOKE DAMPER W /ACCESS PANEL SMOKE DAMPER W /ACCESS PANEL DUCT RISE (OR DROP) EXISTING DUCTWORK TO REMAIN EXISTING DUCTWORK TO REMAIN EXISTING DUCTWORK TO BE REMOVED EXISTING DUCTWORK TO BE REMOVED SUPPLY AIR TERMINAL RETURN /EXHAUST /TRANSFER AIR TERMINAL VAV BOX HORIZONTAL UNIT HEATER VERTICAL UNIT HEATER ACCESS PANEL THERMOSTAT TEMPERATURE SENSOR SMOKE DETECTOR LONG RADIUS ELBOW SHORT RADIUS ELBOW WITH VANES f 12/12 12/12 1L 12/12 f 12/12 f 12/12 12/12 12/12 FD SD IL I I 12/12 f 1 2/1 2 12/12 FSD 12/12 f UP (OR DN) 12/12 IL ,FW/ffri/f Q PLUMBING SYMBOL LEGEND FLOOR SINK W /HALF GRATE IMMIS MEN BALL VALVE 1>G1 GATE VALVE 1`J CHECK VALVE Dail DRAIN VALVE l�l IZI ►i FLOOR DRAIN FLOOR SINK W /FULL GRATE 2 -WAY VALVE SOLENOID VALVE MOTORIZED VALVE EMERGENCY GAS SHUT -OFF VALVE THERMOSTATIC /PRESSURE BALANCE MIXING VALVE TRAP PRIMING VALVE PRESSURE RELIEF VALVE 11 I BUTTERFLY VALVE 1)01 GLOBE VALVE CIRCUIT BALANCING VALVE PLUG VALVE X ANCHOR 11 PIPE FLANGE PIPE GUIDE AIR CHAMBER °r WATER HAMMER ARRESTER —4 WALL HYDRANT/ HOSE BIBB EXPANSION TANK WATER METER 1 FLOW METER THERMOMETER PRESSURE GAGE STRAINER PUMP PLUMBING FIXTURE TAG FLOOR RECEPTOR TAG FLOW SWITCH 3 -WAY VALVE aFP BACKFLOW PREVENTER a REDUCER FLOW ARROW STEAM TRAP (F &T) --r' THERMOSTAT WELL =1 EXPANSION JOINT FLEXIBLE CONNECTOR T TEST PLUG STEAM TRAP CI 0 0 0 III UNION n PIPE CAP 5 PIPE BREAK (THERMOSTATIC) VACUUM RELIEF VALVE AQUASTAT PRESSURE REGULATOR PIPE DOWN PIPE UP TEE DOWN MISC. SYMBOL LEGEND XXX_ 1 EQUIPMENT TAG A REVISION TRIANGLE s CONNECTION TO EXISTING 0 KEY NOTE • SPRINKLER HEAD (SEMI - RECESSED) 0 SPRINKLER HEAD (UPRIGHT) O SPRINKLER HEAD (FULLY RECESSED) PLUMBING LINETYPE LEGEND G G G DOMESTIC COLD WATER DOMESTIC COLD WATER (BELOW FLOOR /GRADE) DOMESTIC COLD WATER (EXISTING) DOMESTIC HOT WATER DOMESTIC HOT WATER (EXISTING) GAS GAS (ON ROOF) GAS (EXISTING) GAS (EXISTING ON ROOF) SANITARY SEWER (ABOVE FLOOR /GRADE) SANITARY SEWER (BELOW FLOOR /GRADE) SANITARY SEWER (EXISTING) VEN T VENT (UNDERFLOOR /GRADE) VENT (EXISTING) SHEET INDEX MO M1 M2 M3 MECHANICAL TITLE SHEET HVAC PLAN PLUMBING PLAN MECHANICAL SPECIFICATIONS FILE C 'PY Permit No REVISIONS No changes shall be made to the cope of work without prior app h Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees- RI'r review approval is subject to ��t o S 0ns. Approval of construction documents r ord'�ancp. Receipt the violation of any adopted ,,' � I$ owta��ed: 0 i t / approved pit 1 R ff �Y a AilWro By City O Tukwila BUILDING DIVISION \\_____, I CODe :IL 2 8 200 APPROVE voti --- p TUI' 11d 13U1 01%G DIV RECEIVED CITY OF TUKWILA JUL 181000 PERMIT CENTER ; lvt'ARATE PERMIT REQUIRED FOR: 0 Mechanical 'Electrical 1 Plumbing Gas Piping City of Tukwila BUILDING DIVISION DATE: 10 u.4 X ecl U 07/08/08 JOB NO: 08- 0196.004 DRAWN: MDB CHECKED: SAC /TLG 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635 -5696 FAX: (817) 635 -5699 v . a E v 2 HALLBE ENGINEERIN REVISIONS SHEET NUMBER MO 1, LANDLORD REVISIONS - 07/10/08 y 4 i7 a � •' () ∎ t,L le; varet Mechanical /Else ric6l■Coheulting Engineers 1750 Commerce Court, Wlilie ° Bear L6ke� MN 55110 (651) 748-1100 • Fax (651) 748 -9370 MECHANICAL TITLE SHEET COOLING COIL PEAK Peaked at Time: MaHr.'7 1'14 CLG SPACE PEAK MaHr: 71 15 TYPE HEATING COIL PEAK MMDIHr: Heating r?eelan B TEMPERATURES Cooling Holding Outside At G A 1 3 0 / B1Hat 79r 6A f 67 VAV -1 SUPPLY OACO: 80 AREA SERVED SALES FLOOR OADEL 26 1 LAND 55.5 700 k ap nea Rheum Ilat Ferment 1 \paw Pasant 2150 apaee Palk Cali Prat Parwol Plenum Mahon 74:0 75.3 7D.11 70.D terra. * 14. lam.* Lot Total Of To taeatbb 13/ Total 28 epaoe keno Toll awn Of Total MAMA c A. 76:6 26.D Btu11 13tt411 041411 CAI 191u9i MI EAT /LAT WW1 EQaia (%t Fn Atk Th B.0 0,0 Envelope Loads ELECTRICAL V -PH -CY 208 -3 -60 DISCONNECT DIV. 16 Eawelope Loads REMARKS 1,2 Fa BadTO a:a a.a 131i Ate Bamr 0 D 0 a a 1 DLylte U itw 0 0 0.00 Fa roof 0.1 00 nfi Ie Land 0 D a a a 0 Myna nand. D 0 003 Roar Can 9 0 u a 0 a Roof Cared a 0 GM fliers Sake D D 0 a a a Gress acor a a arm Glom. Calr a D D D u 0 Grass Cana D a 9.0LI Wail Cars a a a a 0 a MO Can D 0 a.00 AIRFLOWS ParDlon 9 a a C 0 PerbYan 0 0 a.0a Cooling Hulling E]rpused Floor a a a a a Exposed Flora 0 0 0.03 y 55t D ?ttraaar 0 a a a a InfHLra}on a 0 000 tee a D Sub Thar - -A 0 D a a 0 a 50 TOM ---, D 0 0.90 tupply 2.043 D Interact Loads lotion.] aua 14ehan Ralson 2,043 3 0 0 1101•t3 11104 .2,901 14105 25 11104 20 Lk)1114 D D D.O Exhaust 651 0 Pecpe 15,783 16,2419 29 - 1 20 People a 0 0,00 Rm F.rd1 0 a Mc 21 0 21,559 39 21159 52 Mies 0 0 0A0 Auxiliary 0 0 Sub Tarsi -- 43,452 2 53,353 92 41,338 tail Suf Trite - D D 0.1711 Calling Load a a a a a a Calling Load a 0 a.DD ENGINEERING CKS vrnUrmOon Lard a 0 54x2 10 9 0 ~alarm Load a 0 UM DetBaentd. ag Weal D a Ovitandr Sizing a 0 1.11 Carling HM1bM1 OnVedr Edna 9 a a a a Eallara) now 0 GAO 7F OA 31.9 D0 Exhaust. Haa( 924 924 -2 OA p "heat Dom. - 21.176 19ar3D aaariP 013 Gag iup_ Fan lied 0 0 RA Freitag( OHrL a a.Da OTIW11111 431.46 Rat Fan Heat D D a - Addikarld Rama) 0 a.aa Ngten 519.44 creel deal Pkup D 0 0 Bt Is1P 23.10 4.61 Retmat at nankin a a No. People 33 &ow!Tdfal zt? 49,452 1,977 56 ,831 100.00 41,308 101:09 Brand Ta 0 - 21,176 '100.00 COOLING COIL SELECTION AREAS HEATING COIL SELECTION Total Cepmely lam Cap. Con Ahaow Enter flf/1YEUR Learn DBIWBliR Grass To Gbaa Capasdy Coil Airflow Ent LW inn MBh Men [Rea "F "F 00 10 "F "F anlh IN Q14I M911 tan - F •F Meta. Cluj 4.7 S6.8 47.2 2.043.4 766 623 64.9 5516 53,3 50.D Rocs 4459 W1R 11kg OOD 17.0 70.0 70.0 Ana CIg 9-D 013 GD u a D D 0 0 0 pak 0 ARK Hlg 0.13 0 0 3 Opt Vast 3.3 CO 0.12 0 MO 00 ea 9A MD 0.0 E71F1r a Franca( .212 651 26 56 Roof a a a Ramat aD 0 0.0 0.0 roof 4.7 56.3 Wall 0 0 0 1llanadll 0.0 a Ian 0.11 apk vent 0.0 a GO 0.0 Total -21.2 VAV BOX SCHEDULE- 0 TYPE A B O D UNIT TAG VAV -1 SUPPLY RETURN AREA SERVED SALES FLOOR DUCT MOUNT 1 MANUFACTURER TITUS MANUFACTURER k MODEL NUMBER DTQP TITUS 1 CFM 2150 350ZRL 1 MINIMUM CFM 0 l ] 1 INLET DUCT SIZE 14 "0 N000.5 "SP 28 FAN HP 3/4 ELECTRIC HEATING COIL (EHC) KW 10 EAT /LAT 55/70 CONTROL STEPS - ELECTRICAL V -PH -CY 208 -3 -60 DISCONNECT DIV. 16 REMARKS 1,2 GRILLE AND DIFFUSER SCHED. 0 TYPE A B C D ITEM SUPPLY SUPPLY RETURN RETURN DESCRIPTION DUCT MOUNT LAY -IN LAY -IN SURFACE MOUNT MANUFACTURER TITUS TITUS TITUS TITUS MODEL NUMBER TMRA TMSA 350ZRL 350ZRL REMARKS PAINTABLE ADJUSTABLE STD. WHITE FINISH STD. WHITE FINISH PAINTABLE MAIN DUCT BRANCH MANUAL VOLUME DAMPER NO SCALE VAV INLET CONE AND SENSOR FILTERED FAN INLET DUCT NO SCALE HVAC PLAN 1/4" = 1' -0" SPIN -ON BELLNOSE FITTING RIGID ROUND DUCT NOTES: DO NOT BLOCK EQUIPMENT ACCESS DOORS AND PANELS BRANCH DUCT 11' -6" A.F.F DIFFUSER TYP. DIFFUSER /DUCT CONNECTIONS 4" RIGID DUCT EXTENSION ATTACHED TO DIFFUSER NECK FULL SIZE RIGID INLET DUCT. PARALLEL FAN POWERED VAV BOX 18" MIN. OR 3 TIMES INLET CONE DIAMETER WHICHEVER IS GREATER VAV BOX COIL ACCESS PANEL IN BOTTOM OF VAV BOX (MINIMUM 6 "x6 ") HEATING COIL DUCT ACCESS PANEL (MINIMUM 6 "x6 ") DISCHARGE DUCT. 4.00.AIRFLOW DISCHARGE TRANSITION AS REQUIRED TO MATCH VAV OUTLET TO DISCHARGE DUCT. (MAX 22 -1/2 DEG.ANGLE) SLEEVE 16 GAUGE FOR ALL DUCTS UNDER 24" HEIGHT AND 36 " WIDTH, ALL LARGER DUCTS USE 14 GAUGE. 1/8" MAXIMUM VOID BETWEEN SLEEVE AND STRUCTURE PROVIDE SHEET METAL EXTENSION OF EQUAL OR GREATER GAUGE AS DUCT --�_ FIRE DAMPER CENTERED IN SLEEVE FLAT DRIVE (TYPICAL SIDES) S -SLIP (TYPICAL TOP AND BOTTOM) SLEEVE MUST EXTEND 6" MINIMUM PAST BOTH SIDES OF STRUCTURE NO SCALE J i i i i a i i i i l i i i i% L FIRE DAMPER DETAIL LOAD CALCULATIONS NO SCALE RETAINING MINIMUM ANGLE 1 -1/2 "x 1 -1/2 "x1/8 ", 14 GAUGE. ANGLE 1" MINIMUM AND COVER CORNERS OF OPENINGS. SECURE ANGLE TO SLEEVE ONLY ON 8" CENTERS WITH #10 STEEL SCREWS. SECURE FIRE DAMPER TO SLEEVE ON 8" CENTERS WITH #10 STEEL SCREWS. SCREWS MUST NOT INTERFERE WITH DAMPER OPERATION. PROVIDE ACCESS DOOR WITH "FIRE DAMPER" LABEL. LOCATE ON SIDE OR BOTTOM OF DUCT. DOOR SIZE MUST PERMIT ACCESS AND RESETTING TO EACH DAMPER SECTION. VAV Project name: ualasel Name; 17Plape1:121Lmori eguaht.Rao id1 .ffi4V3esI PTmne9313- 0195„,t 4„tc System Checksums By Hallberg Engsleering Inc. Parallel Fan-Powered VAV TRACE 700 u6.0 celnielyd et 3610 AM on 3711112048 hatrta0iVC - 1 D1rkm Cheataaa Report Pone 1 at 1 GENERAL NOTES A. THE MECHANICAL CONTRACTOR IS REQUIRED TO PROVIDE AS PART OF BASE BID A SERVICE CONTRACT INCLUDING ALL FILTER CHANGES AND CLEANING AND MAINTENANCE FOR A PERIOD OF 1 YEAR FROM TURNOVER OF SPACE. B. COORDINATE LOCATIONS OF DIFFUSER GRILLES W /ARCH REFLECTED CEILING PLAN. C. SUBMIT COPIES OF TEST & BALANCE REPORT TO LANDLORD, OWNER & ENGINEER. D. ADJUST DISCHARGE PATTERN OF THE DIFFUSER FOR A VERTICAL FLOW. E. REMOVE ALL EXISTING FIRE SPRINKLER HEADS AND DROP LEGS. PROVIDE NEW HEADS OF TYPE SHOWN. REWORK BRANCHES AND MAINS AS REQUIRED FOR NEW ELEVATION. HEADS TO BE UPRIGHT, SEMI- RECESSED OR FULLY RECESSED. FULLY RECESSED TO BE PROVIDED WITH WHITE COVERS. FIRE PROTECTION WORK TO BE PROVIDED BY LANDLORD APPROVED CONTRACTOR. F. CONTRACTOR SHALL COMPLETELY REMOVE FROM THE PREMISES ALL EQUIPMENT, PIPING, DUCTWORK, CONTROLS, CONTROL WIRING, ETC. AND ALL ASSOCIATED SUPPORTS, BRACING, PADS, ETC. NOT BEING REUSED OR SHOWN ON TO REMAIN WHETHER IN THE DEMISED SPACE, ON THE ROOF OR OTHERWISE LOCATED OUTSIDE OF THE DEMISED SPACE. DO NOT ABANDON IN PLACE. H. DIFFUSER RUNOUT EQUAL TO DIFFUSER CONNECTION UNLESS OTHERWISE SPECIFIED. G. REMOVE ALL UNUSED PIPING, DUCTWORK, AND ACCESSORIES. DO NOT ABANDON. I. ALL EXPOSED ROUND DUCT SHALL BE SPIRAL AND PAINTABLE. J. VERIFY ANY ADDITIONAL HVAC CRITERIA WITH LANDLORD. REQUIREMENTS MAY INCLUDE BUT ARE NOT LIMITED TO: GENERAL HVAC REQUIREMENTS, INSULATION, DUCT AND DUCT FITTINGS, HVAC CONTROLS, HANGERS, AND INSTALLATION. K. SPRINKLER HEAD LOCATIONS ARE FOR REFERENCE ONLY. THE FINAL LOCATIONS NEED TO BE INSTALLED PER CODE AND ARE THE RESPONSIBILITY OF THE CONTRACTOR WHO INSTALLS. L. ALL SUPPORTS SHALL BE FROM STRUCTURAL BEAMS AND JOISTS, NOT FROM THE FLOOR SLAB OR ROOF DECK ABOVE. M. MAINTAIN A MINIMUM OF 6" UNOBSTRUCTED CLEARANCE HEIGHT IN RETURN AIR PLENUM ABOVE CEILING ALLOWING FOR AIR FLOW BACK TO LANDLORD RTU. KEY NOTES • NEW PARALLEL FAN POWERED VAV BOX PROVIDED BY TENANT CONTRACTOR. • PROVIDE NEW 7 -DAY PROGRAMMABLE THERMOSTAT FOR RTU -1 CONTROL MOUNTED 4' -0" A.F.F. COVERED WITH CLEAR LOCAKABLE BOX. REFER TO SPEC 15906 FOR SEQUENCE OF OPERATION. • INSTALL SMOKE DETECTOR FURNISHED BY ELECTRICAL CONTRACTOR IN RETURN OF VAV BOX. DETECTOR SHALL SHUT DOWN HVAC UNIT UPON DETECTION OF SMOKE. 0. EXISTING DUCTWORK TO REMAIN. Q PROVIDE FIRE DAMPER. REFER TO DETAIL 4/M1. 1> EXHAUST FAN PROVIDED BY TENANT CONTRACTOR. MECHANICAL CONTRACTOR TO CONNECT 6 "0 DUCT TO EXISTING (6 "0 MIN) LANDLORD PROVIDED EXHAUST DUCT. FIELD VERIFY EXISTING EXHAUST DUCT LOCATION. REFER TO ELECTRICAL DRAWINGS FOR EXHAUST FAN SPECIFICATION. • MOUNT TRANSFER DUCT AS HIGH AS POSSIBLE. PROVIDE GRILLE ON SALES FLOOR SIDE OF WALL. NOTES: 1. PROVIDE CONTROLS AS REQUIRED TO INTERFACE WITH LANDLORD BUILDING AUTOMATION SYSTEM. 2. BALANCE TO 650 CFM OUTSIDE AIR. ck011010 v. ax ii) JNL 2 8 100 0 MO8l6S RECEIVED CITY OF TUKWILA JUL. 182008 PERMIT CENTER DATE: JOB NO: DRAWN: MDB CHECKED: SAC/TLG 07/08/08 08- 0196.004 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635 -5696 FAX: (817) 635 -5699 ,._ ig ,.., J � 0 o �a Ln r•i4 a t (: ,�;zz d Q uu f%)() 1.6.1 a. = = N 1-. 1.-. :ii! 0 Q V1 cJ'1 M M qD 1,� �4�V,... jf ,, C ,' t .,,,A,5'f :7 HALLBER :iiiiirni_ � �a� ENGINEERING �:��,`, Yechantcal /Electric t(u,� era 1750 Commerce Co ;- VVliite -Bear -take; MN- 55110- (651) 748 -1100 • Fax (651) 748 -9370 REVISIONS HVAC PLAN SHEET NUMBER M1 1. LANDLORD REVISIONS - 07/10/08 BATHROOM COMPONENT SCHEDULE Item Model # Exist. To Remain New (Add /Replace) Notes: Toilet See Plumbing Fixture Schedule - 1 — Toilet Seat See Plumbing Fixture Schedule - 1 -- Sink See Plumbing Fixture Schedule - 1 --- Lever Handle Faucet See Plumbing Fixture Schedule - 1 -- Pipe Wrap See Plumbing Fixture Schedule - 1 -- Water Heater See Water Heater Schedule - 1 -- Service Sink See Plumbing Fixture Schedule - - -- Water Cooler - - - -- Floor Drain See Plumbing Fixture Schedule - 1 -- UNDERFLOOR PLUMBING PLAN 1/4" = n 4* 411 EWH 4 r. KEY NOTES EXTEND AND CONNECT NEW 4" SANITARY SEWER TO EXISTING 4" (MIN) LANDLORD PROVIDED SANITARY SEWER PIPING. FIELD VERIFY EXACT LOCATION, SIZE, FLOW DIRECTION, AND INVERT ELEVATION OF CONNECTION POINT PRIOR TO ROUGH -IN OF NEW SANITARY SEWER. PROVIDE FCO AT POINT OF CONNECTION TO EXISTING. 0 . EXTEND AND CONNECT NEW 3/4" CW PIPING TO EXISTING 3/4" (MIN) LANDLORD PROVIDED CW PIPING. FIELD VERIFY EXACT LOCATION OF CW PIPING PRIOR TO ROUGH -IN. PROVIDE SHUTOFF VALVE AT POINT OF CONNECTION TO EXISTING. PROVIDE A LANDLORD APPROVED REDUCED PRESSURE BACKFLOW PREVENTER ON THE WATER SERVICE WITHIN THE SPACE PRIOR TO MAKING ANY OTHER CONNECTIONS. EXTEND NEW 2" VENT TO EXISTING (2" MIN) LANDLORD PROVIDED VENT PIPING. FIELD VERIFY EXACT LOCATION OF EXISTING VENT PIPING PRIOR TO ROUGH -IN. K PROVIDE JOSAM 88250 OR EQUAL TRAP PRIMER WITH ACCESSIBLE SHUT -OFF VALVE. 0 . PIPE DRIP PAN FULL SIZE TO AIR GAP OVER SERVICE SINK. K PIPE 3/4" FROM ASME RATED T &P VALVE TO AIR GAP OVER FLOOR DRAIN. FIXTURE NO. P1 P2 Fl FIXTURE TYPE WATER CLOSET PRESSURE ASSIST LAVATORY FLOOR DRAIN PLUMBING PLAN 1/4" = 1 MANUFACTURER AMERICAN STANDARD AMERICAN STANDARD JOSAM TYPE & MODEL NO. CADET WHITE 2377.100 LUCERNE (WHITE) 0355.012 30000 -6A D GENERAL NOTES A. VERIFY ALL CONDITIONS IN THE FIELD. B. COORDINATE WORK WITH LANDLORD PRIOR TO AND SLAB DEMOLITION. COORDINATE WITH LANDLORD TO PROVIDE OPPORTUNITY FOR SPECIAL INSPECTION AND PHOTOGRAPHIC DOCUMENTATION BY LANDLORD OF BELOW GRADE WORK PRIOR TO THE COVERING UP OF SUCH WORK. TENANT CONTRACTOR SHALL BE RESPONSIBLE FOR RECONSTRUCTION AND PATCHING OF THE SLAB -ON -GRADE SYSTEM, INCLUDING GRAVEL LAYERS, VAPOR BARRIER, AND CONCRETE. C. ALL SUPPORTS SHALL BE FROM STRUCTURAL BEAMS AND JOISTS, NOT FROM FLOOR OR ROOF DECK ABOVE. ELECTRIC WATER HEATER SCHEDULE EWH UNIT NO. EWH -1 MANUFACTURER A.O. SMITH MODEL DEL -6 CAPACITY (GAL.) KW 1.5 STAGES 1 VOLTAGE 120 1 60 OUTPUT (GPH C 90` RISE 7 REMARKS NONE PLUMBING FIXTURE SCHEDULE TRIM NO. CHICAGO FAUCET 1016 CHICAGO FAUCET 894-317 SUPPORT FLOOR M OU N T WALL HUNG TRAP 1 - / 2" 3 " WASTE PIPE WASTE AND VENT RISER N.T.S. VENT SIZES 4 2" 3 11 2 " 1 -1/2" 1 - 1/2" 2 " CW 1/2" 1/ HW 1 /2" REMARKS WHITE SEAT - CHURCH MODEL 295C 16-1/2" RIM HEIGHT PROVIDE INSULATED CAST BRASS P -TRAP, HANDICAP INSULATION KIT, (2) CHICAGO FAUCET 1016 ANGLE VALVES, WALL CARRIER 0.5 GPM FLOW LIMIT PROVIDE 1/2" TRAP PRIMER CONNECTION WHERE INDICATED ON PLANS N.T.S. WATER RISER RECEIVED CITY OF TUKWIA dill_ 1$1008 PERMIT CENTER DATE: JOB NO: Mob - l82 07/08/08 08- 0196.004 DRAWN: MDB CHECKED: SAC /TLG 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635 -5696 FAX: (817) 635 -5699 l Uti WAS 7 / Q J � p LLI a w zz a u u D n 0 0 M M \O C ;j >[1✓tty jt � HALLBE ENGINEERIN ToatrConsulflng Engineers 1750 CommerceCourf, - Luke; MN 55110 (651) 748 -1100 • Fax (651) 748 -9370 REVISIONS 1. LANDLORD REVISIONS - 07/10/08 PLUMBING PLAN SHEET NUMBER M2 15010 GENERAL PROVISIONS A. FURNISHING LABOR, MATERIALS, EQUIPMENT AND SERVICES REQUIRED AS SHOWN ON THE DRAWINGS AND SPECIFIED IN DIVISION 15. B. ALL WORK SHALL BE COMPLETE AND SHALL BE LEFT IN OPERATING CONDITION. C. INCLUDE ALL PARTS AND LABOR WHICH ARE INCIDENTAL AND NECESSARY FOR A COMPLETE AND OPERABLE INSTALLATION EVEN THOUGH NOT SPECIFICALLY MENTIONED IN THE CONTRACT DOCUMENTS. D. ARRANGE WITH APPROPRIATE UTILITY COMPANIES TO PROVIDE TEMPORARY AND PERMANENT UTILITY SERVICES AS REQUIRED AND COORDINATE THEIR INSTALLATION WITH CONSTRUCTION PROGRESS OF THIS PROJECT. PAY ALL FEES AND COSTS CHARGED BY UTILITY COMPANIES FOR UTILITY SERVICES. E. OBTAIN ALL TEMPORARY AND PERMANENT PERMITS AND LICENSES REQUIRED IN CONNECTION WITH THIS DIVISION'S WORK. PAY ALL FEES AND EXPENSES REQUIRED FOR SUCH PERMITS AND LICENSES. F. REQUEST INSPECTIONS AS REQUIRED BY REGULATING AGENCIES AND /OR REGULATIONS. PAY ALL CHARGES FOR INSPECTIONS BY REGULATING AGENCIES OF INSTALLATIONS OF PLANS SPECIFICATIONS. G. PROVIDE THE OWNER WITH A CERTIFICATE OF FINAL INSPECTION AND APPROVAL BY ENFORCEMENT AUTHORITIES. H. MEET OR EXCEED ALL CURRENT APPLICABLE CODES, ORDINANCES AND REGULATIONS FOR ALL INSTALLATIONS. PROMPTLY NOTIFY THE ENGINEER, IN WRITING, IF THE CONTRACT DOCUMENTS APPEAR TO CONFLICT WITH GOVERNING CODES AND REGULATIONS. CONTRACTOR ASSUMES ALL RESPONSIBILITY AND COSTS FOR CORRECTING NON - COMPLYING WORK INSTALLED WITHOUT NOTIFYING THE ENGINEER. I. HIGHER QUALITY OF WORKMANSHIP AND MATERIALS INDICATED IN THE CONTRACT DOCUMENTS TAKES PRECEDENCE OVER THAT ALLOWED IN REFERENCED CODES AND STANDARDS. FURNISH: TO OBTAIN, COORDINATE, SUBMIT THE NECESSARY DRAWINGS, DELIVER TO THE JOB SITE IN NEW CONDITION READY FOR INSTALLATION, UNLOAD AND UNPACK, AND GUARANTEE. J. INSTALL: TO RECEIVE AT THE JOB SITE, STORE, ASSEMBLE, ERECT, SET IN PLACE, ANCHOR, APPLY, FINISH, PROTECT, CLEAN, TEST, START -UP, AND MAKE READY FOR OWNER'S USE. K. PROVIDE: TO FURNISH AND INSTALL. L. CONTRACTOR IS RESPONSIBLE FOR DIMENSIONAL DIFFERENCES, WEIGHTS, ELECTRICAL REQUIREMENTS AND ANY OTHER RESULTING CHANGES, WHEN USING EQUIPMENT OTHER THAN THAT SCHEDULED ON THE DRAWINGS. CONTRACTOR IS RESPONSIBLE FOR ANY ADDITIONAL COSTS INCURRED AS A RESULT OF SUBSTITUTIONS. M. BEFORE SUBMITTING A PROPOSAL ON THE WORK CONTEMPLATED, EXAMINE THE SITE OF THE PROPOSED WORK AND BECOME THOROUGHLY FAMILIAR WITH EXISTING CONDITIONS AND LIMITATIONS. NO EXTRA COMPENSATION WILL BE ALLOWED BECAUSE OF MISUNDERSTANDING AS TO THE AMOUNT OF WORK INVOLVED NOR BIDDERS LACK OF KNOWLEDGE OF EXISTING CONDITIONS WHICH COULD HAVE BEEN DISCOVERED OR REASONABLY ANTICIPATED PRIOR TO BIDDING. N. MECHANICAL EQUIPMENT AND SYSTEMS SHOWN ON THE DRAWINGS AS EXISTING, HAVE BEEN BASED ON EXISTING PLANS, AND MAY NOT BE INSTALLED AS ORIGINALLY SHOWN. IT IS THE CONTRACTORS RESPONSIBILITY TO VISIT THE SITE AND MAKE EXACT DETERMINATION OF THE EXISTENCE, LOCATION AND CONDITION OF SUCH FACILITIES PRIOR TO SUBMITTING A BID. 0. CONSULT THE DRAWINGS AND SPECIFICATIONS OF DIVISION 16 AND OTHER TRADES FOR CORRELATING INFORMATION AND LAY OUT WORK SO THAT IT WILL COORDINATE WITH OTHER TRADES. VERIFY DIMENSIONS AND CONDITIONS (I.E., FINISHED CEILING HEIGHTS, FOOTING AND FOUNDATION ELEVATIONS, BEAM DEPTHS, ETC.) WITH THE ARCHITECTURAL AND STRUCTURAL DRAWINGS. P. DRAWINGS MAY NOT SHOW EVERY RISE AND OFFSET REQUIRED FOR THE WORK. INSTALL PIPING AND DUCTWORK TO ACCOMMODATE THE BUILDING STRUCTURE AND THE WORK OF OTHER TRADES, WITH ALL REQUIRED OFFSETS AND WITHOUT EXTRA COST TO THE OWNER. Q. OBTAIN EXACT LOCATION OF CONNECTION TO EQUIPMENT, FURNISHED BY OTHERS, FROM THE PERSON FURNISHING THE EQUIPMENT. R. GUARANTEE AND MAINTAIN THE STABILITY OF WORK AND MATERIALS AND KEEP SAME IN PERFECT REPAIR AND CONDITION FOR THE PERIOD OF ONE (1) YEAR AFTER THE FINAL COMPLETION OF THE WORK AS EVIDENCED BY ISSUANCE OF THE FINAL CERTIFICATE BY THE ARCHITECT. S. DEFECTS OF ANY KIND DUE TO FAULTY WORK OR MATERIALS APPEARING DURING THE ABOVE MENTIONED PERIOD MUST BE IMMEDIATELY MADE GOOD BY THE CONTRACTOR AT HIS OWN EXPENSE TO THE ENTIRE SATISFACTION OF THE OWNER AND ARCHITECT AND ENGINEER. INCLUDE DAMAGE TO THE FINISH OR THE BUILDING RESULTING FROM THE ORIGINAL DEFECT OR REPAIRS. T. MAGNETIC STARTERS, DISCONNECTS, AND POWER WIRING PROVIDED BY THE ELECTRICAL CONTRACTOR, UNLESS OTHERWISE SPECIFIED. U. CONTROL AND INTERLOCK WIRING PROVIDED BY THE MECHANICAL CONTRACTOR, UNLESS OTHERWISE SPECIFIED. V. PROVIDE ONLY PRODUCTS FROM MANUFACTURERS WITH LOCAL REPRESENTATION THAT CAN PROVIDE COMPLETE COVERAGE, PARTS AND LABOR, FOR REPLACEMENT AND SERVICE OF THEIR PRODUCTS. PROVIDE ONLY EQUIPMENT THAT WILL FIT IN THE SPACE AVAILABLE AND BE COMPLETELY SERVICEABLE. BRING ANY CONFLICTS TO THE ENGINEER'S ATTENTION PRIOR TO ORDERING THE EQUIPMENT. W. COORDINATE /SCHEDULE ALL WORK WITH THE OWNER TO MINIMIZE ANY DISRUPTIONS. CONFINE ALL INTERRUPTIONS TO THE SMALLEST POSSIBLE AREA. PROVIDE TEMPORARY CONNECTIONS IF REQUIRED TO PROVIDE CONTINUITY OF SERVICE. X. INSPECT ALL AREAS AFFECTED BY THE INTERRUPTIONS AND RETURN ALL AUTOMATICALLY CONTROLLED EQUIPMENT, ELECTRICALLY OPERATED EQUIPMENT TO THE SAME OPERATING CONDITION PRIOR TO THE INTERRUPTION. Y. NO FIRE SPRINKLER OR FIRE ALARM SYSTEMS ARE TO REMAIN INACTIVE AT THE END OF THE WORK DAY. ASSURE THAT THE FIRE SPRINKLER OR FIRE ALARM SYSTEM IS OPERATIONAL AT THE END OF EACH WORK DAY. COORDINATE WITH THE OWNER. Z. PROVIDE NEW MATERIAL AND EQUIPMENT, UNLESS NOTED OTHERWISE. PROTECT EQUIPMENT AND THE FROM DAMAGE, DIRT AND HE WE ATHER. M. PROVIDE THE HIGHEST QUALITY WORKMANSHIP AND PERFORM ALL WORK ONLY BY SKILLED MECHANICS. INSTALL MATERIAL AND EQUIPMENT IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS, INSTRUCTIONS AND CURRENT STANDARDS. BB. THE ENGINEER RESERVES THE RIGHT TO REJECT MATERIAL OR WORKMANSHIP NOT IN ACCORDANCE WITH THE CONTRACT DOCUMENTS, BEFORE OR AFTER INSTALLATION. CC. ALL PIPING AND DUCTWORK SHALL BE RUN IN THE MOST DIRECT AND STRAIGHT MANNER POSSIBLE MAINTAINING PROPER GRADING. DD. IT IS THE INTENT OF THESE PLANS AND SPECIFICATIONS THAT MOST PIPING AND DUCTWORK BE CONCEALED. WHERE EXPOSED, RUN AS CLOSE TO CEILING AND /OR WALL AS POSSIBLE PARALLEL WITH ADJACENT STRUCTURAL OR ARCHITECTURAL ELEMENTS. EE. DO NOT INSTALL PIPING OR DUCTWORK IN ANY SWITCHGEAR, TRANSFORMER, ELEVATOR EQUIPMENT, TELEPHONE, OR ELECTRICAL EQUIPMENT ROOM, UNLESS IT IS A BRANCH SERVING THAT ROOM. FF. DO NOT INSTALL PIPING OR DUCTWORK ABOVE SWITCHBOARDS, PANELBOARDS, CONTROL PANELS, MOTOR CONTROL CENTERS, ETC. GG. ARRANGE WORK TO FACILITATE MAINTENANCE, REPAIR OR REPLACEMENT OF EQUIPMENT. PROVIDE ACCESS FOR DEVICES THAT REQUIRE MAINTENANCE. FOR CONCEALED DEVICES, VERIFY THAT ACCESS PANELS ARE PROPERLY LOCATED AND LABELED. HH. INSTALL MATERIAL AND EQUIPMENT IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN INSTRUCTIONS. II. PERFORM ALL CUTTING AND PATCHING NECESSARY TO WORK, UNLESS SPECIFICALLY DELEGATED TO THE GENERAL CONTRACTOR, OBTAIN SPECIAL PERMISSION FROM THE STRUCTURAL ENGINEER BEFORE CUTTING STRUCTURAL MEMBERS OR FINISHED MATERIAL. PERFORM ALL PATCHING IN SUCH A MANNER AS TO LEAVE NO VISIBLE TRACE AND RETURN THE AREA AFFECTED TO THE CONDITION OF UNDISTURBED WORK. PERFORM ALL PATCHING BY WORKERS EXPERIENCED, SKILLED, AND LICENSED FOR THE PARTICULAR TYPE OF WORK INVOLVED. INFERIOR WORK WILL NOT BE ACCEPTED. JJ. PATCH ALL HOLES LEFT AS A RESULT OF DEMOLITION OF MECHANICAL EQUIPMENT AND DEVICES. KK. DRILL ALL HOLES IN MASONRY WITH ROTARY DRILL. IMPACT TOOLS ARE NOT ALLOWED. CORE DRILL ALL HOLES IN MASONRY AND CONCRETE FOR MECHANICAL PENETRATIONS. PROVIDE AND DISPOSE OF ALL WATER REQUIRED FOR CORE DRILLING. COORDINATE WITH OTHER TRADES TO PREVENT DAMAGE FROM WATER. LL. PREVENT THE SPREAD OF DUST, DEBRIS, AND OTHER MATERIAL INTO ADJACENT AREAS. MM. REPLACE ALL CEILING TILES DAMAGED DURING INSTALLATION OF WORK, WITH NEW TILE. NN. REFINISH ALL MECHANICAL EQUIPMENT DAMAGED DURING SHIPPING AND /OR INSTALLATION TO ITS ORIGINAL CONDITION. REMOVE ALL RUST; PRIME, AND PAINT PER MANUFACTURER'S RECOMMENDATIONS FOR FINISH EQUAL TO ORIGINAL. 00. DO NOT USE HEATING, VENTILATING AND AIR CONDITIONING SYSTEMS PROVIDED IN THIS SCOPE OF WORK FOR TEMPORARY HEATING, VENTILATING AND AIR CONDITIONING DURING CONSTRUCTION. PP. PROTECT OPENINGS AND EQUIPMENT FROM OBSTRUCTION, BREAKAGE, MISUSE, DAMAGE OR BLEMISHES. PROTECT MATERIALS AND EQUIPMENT IMMEDIATELY UPON RECEIPT AT THE JOB SITE OR IMMEDIATELY AFTER THEY HAVE BEEN REMOVED FROM THEIR SHIPPING CONTAINERS. UNLESS NOTED OTHERWISE, KEEP THEM CLEAN AND UNDAMAGED UNTIL FINAL ACCEPTANCE OF THE ENTIRE PROJECT BY THE OWNER. WHEN A PORTION OF THE BUILDING IS OCCUPIED BY THE OWNER BEFORE SUBSTANTIAL COMPLETION OF THE ENTIRE PROJECT, MAKE ARRANGEMENTS TO TRANSFER RESPONSIBILITY FOR PROTECTION AND HOUSEKEEPING FOR THE OCCUPIED PORTION. QQ. PROTECT PIPE, DUCT AND EQUIPMENT OPENINGS WITH TEMPORARY PLUGS OR CAPS. KEEP OPENINGS COVERED UNTIL PERMANENT CONNECTIONS ARE COMPLETE. RR. CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO MECHANICAL EQUIPMENT, MATERIALS OR WORK UNTIL FINAL ACCEPTANCE OF THE ENTIRE PROJECT BY THE OWNER. KEEP THE PREMISES FREE FROM ACCUMULATION OF WASTE MATERIAL OR RUBBISH, CAUSED BY HIS EMPLOYEES OR WORK, AT ALL TIMES. REMOVE RUBBISH, TOOLS, SCAFFOLDING, AND SURPLUS MATERIALS FROM AND ABOUT THE BUILDING, AND LEAVE WORK AREAS "BROOM CLEAN" OR ITS EQUIVALENT UPON COMPLETION OF THE WORK. CLEAN MECHANICAL EQUIPMENT AND REMOVE TEMPORARY IDENTIFICATION. SS. IN CASE OF DISPUTE, THE OWNER WILL REMOVE THE RUBBISH AND CHARGE THE COST TO THE CONTRACTOR. TT. BEFORE START -UP, LUBRICATE, CHARGE, AND FILL SYSTEMS AS SPECIFIED AND ACCORDING TO MANUFACTURER'S INSTRUCTIONS. UU. CLEAN, DISINFECT, AND TEST ALL PLUMBING AND PIPING SYSTEMS, W. PERFORM TESTING, ADJUSTING AND BALANCING IN ACCORDANCE WITH THAT SECTION. WW. OPERATE EQUIPMENT AND SYSTEMS IN ALL THEIR OPERATING MODES, TO VERIFY PROPER OPERATION, PRIOR TO FINAL FIELD OBSERVATION AND OWNER INSTRUCTIONS. XX. ATTEND PRE - TESTING CONFERENCE AS SCHEDULED BY TESTING, ADJUSTING AND BALANCING CONTRACTOR. YY. PROVIDE ASSISTANCE TO TEST, ADJUSTING AND BALANCING CONTRACTOR BY MAKING ADJUSTMENTS TO SYSTEM AND SYSTEM COMPONENTS REQUIRED FOR ACHIEVING DESIGN PERFORMANCE. ZZ. IF ACCEPTABLE PERFORMANCE OF ANY TEST IS NOT ACHIEVED, MAKE THE NECESSARY CORRECTIONS AND THE TEST SHALL BE REPEATED UNTIL ACCEPTABLE PERFORMANCE IS ACHIEVED. MA. FULLY INSTRUCT THE OWNER'S DESIGNATED PERSONNEL IN THE OPERATION OF EACH MECHANICAL SYSTEM AT THE TIME IT IS PUT INTO SERVICE. PROVIDE INSTRUCTION USING COMPETENT INSTRUCTORS AND FACTORY TRAINED PERSONNEL. BBB. INCLUDE DOCUMENTATION OF INSTRUCTIONS IN THE OPERATION AND MAINTENANCE MANUALS. CCC. OBTAIN A WRITTEN STATEMENT FROM THE OWNER THAT HIS DESIGNATED PERSONNEL HAVE BEEN INSTRUCTED. DDD. SUBMIT COMPLETED BOUND OPERATION AND MAINTENANCE MANUALS TO OWNER INCLUDING SHOP DRAWINGS, WARRANTIES, TEST REPORTS, CERTIFICATIONS, TEST AND BALANCE REPORTS, SYSTEM EEE. ALL SUPPORTS SHALL BE FROM STRUCTURAL BEAMS AND JOISTS, NOT FROM FLOOR OR ROOF DECK ABOVE. • • 1 15025 DEMOLITION A. FURNISH LABOR, EQUIPMENT, AND MATERIALS REQUIRED FOR CUTTING, DEMOLITION, REMOVAL, PATCHING, AND RESTORATION WORK NECESSARY TO ACCOMPLISH AND COMPLETE ALL DEMOLITION, INCLUDING ANY RELOCATION OR REUSE OF EXISTING MATERIALS, EQUIPMENT, SYSTEMS, AS WELL AS THE DISPOSITION OF SALVAGED MATERIALS OR DEBRIS. B. ACCOMPLISH ALL WORK OF CUTTING, REMOVAL, DEMOLITION, RELOCATION, PATCHING, AND RESTORATION BY USING ONLY MECHANICS SKILLED IN THE TRADE REQUIRED. PROVIDE FOR THE SAFETY OF THE EXISTING BUILDING AND PERSONNEL, AS WELL AS FOR NEW CONSTRUCTION AS A RESULT OF WORK, PROCEDURES, OPERATIONS OR ACTIVITIES UNDER THIS CONTRACT. C. WHERE THE WORK OF REMOVALS, DEMOLITION, CUTTING AND SIMILAR WORK INVOLVES STRUCTURAL CONSIDERATIONS, CONSULT WITH STRUCTURAL ENGINEER. EXERCISE EXTREME CARE TO AVOID DAMAGE AND PRESERVE THE SAFETY OF THE STRUCTURE AND OF ALL PERSONNEL. PARTICULAR CARE MUST BE TAKEN WHERE THE DEMOLITION OR REMOVALS OCCUR ADJACENT TO OCCUPIED AREAS. D. UTILIZE COMPETENT AND QUALIFIED TECHNICAL ASSISTANCE TO DEVELOP SAFE METHODS AND TECHNIQUES TO ACCOMPLISH THE WORK, INCLUDING TEMPORARY SHORING AND SUPPORTS, METHODS OF REMOVAL AND OTHER CONSIDERATIONS. DESIGN AND PLACE ALL PERMANENT OR TEMPORARY SUPPORTS TO CARRY ALL LOADS DOWN TO SOUND BEARING. 15081 DUCTWORK INSULATION A. MATERIALS: CONFORM TO MAXIMUM FLAME SPREAD /SMOKE DEVELOPED RATING OF 25/50 IN ACCORDANCE WITH ASTM E84, NFPA 255 AND UL 723. B. CONFORM TO ASTM STANDARDS FOR "K" VALUE, MOISTURE VAPOR TRANSMISSION, MAXIMUM MOISTURE ABSORPTION, JACKET, INSULATING CEMENT, AND ADHESIVE. C. MANUFACTURER: SCHULLER- MANVILLE 800 SERIES SPIN -GLAS 1. GLASS FIBER (FLEXIBLE/RIGID): SCHULLER - MANVILLE 800 SERIES SPIN -GLAS. EQUIVALENT PRODUCTS: CERTAINTEED, KNAUF, OWENS- CORNING. 2. GLASS FIBER DUCT LINER, FLEXIBLE: SCHULLER - MANVILLE PERMACOTE LINACOUSTIC STANDARD. EQUIVALENT PRODUCTS: CERTAINTEED, KNAUF, OWENS - CORNING. 3. INSTALL IN ACCORDANCE WITH NAIMA NATIONAL INSULATION STANDARDS. D. EXHAUST AND RELIEF AIR DUCTS WITHIN 10 FT OF EXTERIOR OPENINGS: FLEXIBLE GLASS FIBER BLANKET - EXTERNAL: 1 -1/2 INCHES THICK. E. SUPPLY DUCTS - EXPOSED: NONE REQUIRED. 15083 PIPING INSULATION A. CONFORM TO MAXIMUM FLAME SPREAD /SMOKE DEVELOPED RATING OF 25/50 IN ACCORDANCE WITH ASTM E84, NFPA 255 AND UL 723. B. CONFORM TO ASTM STANDARDS FOR "K" VALUE, MOISTURE VAPOR TRANSMISSION, MAXIMUM MOISTURE ABSORPTION, JACKET, INSULATING CEMENT, AND ADHESIVE. C. MANUFACTURER:GLASS FIBER: SCHULLER-MANVILLE,CERTAINTEED, KNAUF, OWENS- CORNING. 1. CELLULAR FOAM: ARMSTRONG, HALSTEAD, IMCOAINOMACO, RUBATEX, ARMAFLEX 2000. D. INSTALL IN ACCORDANCE WITH NAIMA NATIONAL INSULATION STANDARDS. VERIFY THAT PIPING HAS BEEN TESTED BEFORE APPLYING INSULATION MATERIALS. VERIFY THAT SURFACES ARE CLEAN AND DRY, WITH FOREIGN MATERIAL REMOVED. E. CONTINUE INSULATION THROUGH WALLS, SLEEVES, PIPE HANGERS, AND OTHER PIPE PENETRATIONS. FINISH AT SUPPORTS, PROTRUSIONS, AND INTERRUPTIONS. F. BURIED PIPING: PROVIDE FACTORY FABRICATED ASSEMBLY WITH INNER ALL - PURPOSE SERVICE JACKET WITH SELF - SEALING LAP, AND ASPHALT IMPREGNATED OPEN MESH GLASS FABRIC, WITH ONE MIL THICK ALUMINUM FOIL SANDWICHED BETWEEN THREE LAYERS OF BITUMINOUS COMPOUND; OUTER SURFACE FACED WITH A POLYESTER FILM. G. SCHEDULE: INSULATION THICKNESS PER LOCAL CODE OR ASHRAE STANDARD 90.1 -1999, WHICHEVER IS MORE STRINGENT. 15100 PLUMBING PIPING A. SANITARY PIPING. 1. CAST IRON PIPE: ASTM A74 SERVICE WEIGHT, FITTINGS: CAST IRON, JOINTS: HUB- AND - SPIGOT, COMPRESSION TYPE WITH NEOPRENE GASKETS OR LEAD AND OAKUM. 2. CAST IRON PIPE: CISPI 301, HUBLESS, FITTINGS: CAST IRON, JOINTS: NEOPRENE GASKET AND STAINLESS STEEL CLAMP AND SHIELD ASSEMBLIES. 3. ABS PIPE (BELOW GRADE): ASTM D2661, FITTINGS: ABS, JOINTS: SOLVENT WELD. 4. COPPER TUBE (ABOVE GRADE): ASTM B88 TYPE "L ", HARD TEMPER ONLY. EXCEPT THESE MATERIALS SHALL NOT BE USED TO RECEIVE THE WASTES FROM URINALS NOR WASTES FROM WATER CLOSETS IN BATTERY, FITTINGS: CAST BRONZE, OR WROUGHT COPPER, JOINTS: SOLDER, GRADE 50B. B. WATER PIPING. 1. COPPER TUBING (BELOW GRADE): ASTM B88, TYPE "K" SOFT COPPER, FITTINGS: CAST COPPER ALLOY OR WROUGHT COPPER AND BRONZE, JOINTS: BCUP SILVER BRAZE. 2. COPPER TUBING (ABOVE GRADE): ASTM B88, TYPE "L" HARD DRAWN, FITTINGS: CAST COPPER ALLOY OR WROUGHT COPPER AND BRONZE, JOINTS: BCUP SILVER BRAZE. C. VERIFY THAT EXCAVATIONS ARE TO REQUIRED GRADE, DRY, AND NOT OVER- EXCAVATED. D. PREPARE PIPING CONNECTIONS TO EQUIPMENT WITH FLANGES OR UNIONS. E. PROVIDE NON - CONDUCTING DIELECTRIC CONNECTIONS WHEREVER JOINTING DISSIMILAR METALS. F. INSTALL VENT PIPING PENETRATING ROOFED AREAS TO MAINTAIN INTEGRITY OF ROOF ASSEMBLY. G. WHERE PIPE SUPPORT MEMBERS ARE WELDED TO STRUCTURAL BUILDING FRAMING, SCRAPE, BRUSH CLEAN, AND APPLY ONE COAT OF ZINC RICH PRIMER TO WELDING. H. PROVIDE SUPPORT FOR UTILITY METERS IN ACCORDANCE WITH REQUIREMENTS OF UTILITY COMPANIES. I. PREPARE EXPOSED, UNFINISHED PIPE, FITTINGS, SUPPORTS, AND ACCESSORIES READY FOR FINISH PAINTING. J. SLEEVE PIPES PASSING THROUGH PARTITIONS, WALLS AND FLOORS. K. USE GROOVED MECHANICAL COUPLINGS AND FASTENERS ONLY IN ACCESSIBLE LOCATIONS. L. PROVIDE UNIONS DOWNSTREAM OF VALVES AND AT EQUIPMENT OR APPARATUS CONNECTIONS. M. PROVIDE BRASS MALE ADAPTERS EACH SIDE OF VALVES IN COPPER PIPED SYSTEM. SOLDER ADAPTERS TO PIPE. N. ESTABLISH INVERT ELEVATIONS, SLOPES FOR DRAINAGE TO 1/4 INCH PER FOOT (SMALLER THAN 3 INCH PIPE), AND 1/8 INCH PER FOOT (3 INCHES AND LARGER) MINIMUM. MAINTAIN GRADIENTS. 0. SLOPE WATER PIPING MINIMUM 0.25 PERCENT AND ARRANGE TO DRAIN AT LOW POINTS. P. PROVIDE NEW SANITARY SEWER SERVICES. BEFORE COMMENCING WORK CHECK INVERT ELEVATIONS REQUIRED FOR SEWER CONNECTIONS, CONFIRM INVERTS AND ENSURE THAT THESE CAN BE PROPERLY CONNECTED WITH SLOPE FOR DRAINAGE AND COVER TO AVOID FREEZING. Q. PROVIDE SUPPORT AND EQUIPMENT REQUIRED TO CONTROL EXPANSION AND CONTRACTION OF PIPING. PROVIDE LOOPS, PIPE OFFSETS, AND SWING JOINTS, OR EXPANSION JOINTS WHERE REQUIRED. R. PROVIDE HANGERS IN QUANTITY AND SPACING REQUIRED TO SUFFICIENTLY SUPPORT PIPING. 15110 VALVES &PLUMBING SPECIALTIES A. MANUFACTURERS: 1. GATE VALVES (UP TO AND INCLUDING 2 "): STOCKHAM MODEL B -105, OR EQUIVALENT BY: a. HAMMOND, KITZ, MILWAUKEE, NIBCO, CRANE. 2. BALL VALVES (UP TO AND INCLUDING 2 "): APOLLO 77- 100/77 -200 SERIES, OR EQUIVALENT BY: a. HAMMOND, KITZ, MILWAUKEE, NIBCO, WATTS, CRANE. 3. SWING CHECK VALVES (UP TO AND INCLUDING 2- 1/2 "): STOCKHAM MODEL B -309/B -319, OR EQUIVALENT BY: a. HAMMOND, KITZ, MILWAUKEE, NIBCO, CRANE. 4. TEMP. AND PRESS. RELIEF VALVE (UP TO 80,000 BTU INPUT): WATTS 10L MODEL M7 5. WATER HAMMER ARRESTOR: WATTS SERIES 15 6. BACKFLOW PREVENTER: WATTS 9BD 7. VACUUM BREAKER: WATTS N36 - %" 8. PRESSURE REDUCING VALVE: WATTS SERIES U5 9. ATMOSPHERIC VACUUM BREAKER: WATTS SERIES 288A 10. HOSE END VACUUM BREAKER: WATTS SERIES 8 11. DIELECTRIC UNION: WATTS SERIES 3000 12. TRAP SEAL PRIMER VALVE: JOSAM 88250, OR EQUIVALENT BY: A. J.R. SMITH, WADE, ZURN B. INSTALL APPROVED POTABLE WATER PROTECTION DEVICES ON PLUMBING LINES WHERE CONTAMINATION OF DOMESTIC WATER MAY OCCUR; JANITOR ROOMS, FIRE SPRINKLER SYSTEMS, PREMISE ISOLATION. C. INSTALL WATER HAMMER ARRESTORS COMPLETE WITH ACCESSIBLE ISOLATION VALVE ON HOT AND COLD WATER SUPPLY PIPING WHERE REQUIRED BY CODE AND PER MANUFACTURERS RECOMMENDATIONS /REQUIREMENTS. D. INSTALL AIR CHAMBERS ON HOT AND COLD WATER SUPPLY PIPING TO EACH FIXTURE OR GROUP OF FIXTURES (EACH WASHROOM). FABRICATE SAME SIZE AS SUPPLY PIPE OR 3/4 INCH MINIMUM, AND MINIMUM 18 INCHES LONG. 15325 SPRINKLER SYSTEMS A. CONTRACTOR SHALL DESIGN AND CALCULATE THE NEW AND RENOVATION OF EXISTING PIPING SYSTEMS, INCLUDING PIPE SCHEDULE, LOCATION OF ALL VALVES, DEVICES, AND SPRINKLER HEADS. DESIGN SPRINKLER SYSTEM PIPING BASED ON HAZARD RATING AS OF THE MOST STRINGENT OF THE REGULATING AGENCIES RESPONSIBLE FOR THIS FACILITY, INCLUDING THE OWNER INSURANCE COMPANY REQUIREMENTS AND THE GOVERNING AUTHORITIES, FM OR AS DETERMINED BY LOCAL REQUIREMENTS. PERFORM WORK IN ACCORDANCE WITH NFPA 13. B. SUBMIT SHOP DRAWINGS, PRODUCT DATA, AND CALCULATIONS TO AUTHORITY HAVING JURISDICTION, AND OWNER'S INSURANCE UNDERWRITER FOR APPROVAL. SUBMIT PROOF OF APPROVAL TO ARCHITECT/ENGINEER. C. PROVIDE EXTRA SPRINKLERS UNDER PROVISIONS OF NFPA 13. D. PROVIDE SUITABLE WRENCHES FOR EACH SPRINKLER TYPE. E. PROVIDE METAL STORAGE CABINET FOR EXTRA SPRINKLERS LOCATED ADJACENT TO THE VALVE ASSEMBLY. F. SPRINKLER MANUFACTURERS: AUTOMATIC SPRINKLER OF AMERICA, RELIABLE AUTOMATIC SPRINKLER COMPANY, STAR SPRINKLER COMPANY, VIKING CORPORATION. G. INSTALL SYSTEM IN ACCORDANCE WITH NFPA 13. H. INSPECTOR'S TEST CONNECTION: FOR EACH SPRINKLER SYSTEM AND FOR EACH WATERFLOW ALARM DEVICE, WHERE MULTIPLE DEVICES OCCUR, PROVIDE AN INSPECTOR'S TEST ASSEMBLY. I. WATER CURTAINS AT NON -RATED OPENINGS: 1. INSTALL SPRINKLER HEADS ON 6 FOOT CENTERS TO PROVIDE A WATER CURTAIN AT NON -FIRE RATED DOORS AND WINDOWS. LOCATE SPRINKLER HEADS WITHIN 1 FOOT OF THE DOOR OR WINDOW ON BOTH SIDES OF THE DOOR AND WINDOW. 2. SPRINKLER HEADS ARE TO BE SUPPLIED FROM THE WET OVERHEAD SPRINKLER SYSTEM. 3. WATER CURTAIN SPRINKLER HEADS ARE TO BE CALCULATED AS A PART OF THE OVERHEAD WET SPRINKLER SYSTEM WITH A MINIMUM DESIGN DISCHARGE OF 3 GPM PER LINEAL FOOT WITH NO SPRINKLER DISCHARGING LESS THAN 15 GPM. MINIMUM PRESSURE AT A SPRINKLER HEAD IS TO BE 7 PSI. J. EXISTING FIRE PROTECTION SYSTEMS: 1. IN BUILDINGS WITH EXISTING FIRE PROTECTION SYSTEMS, THE CONTRACTOR SHALL CLOSELY COORDINATE HIS WORK WITH THE OWNER TO MINIMIZE DISRUPTION OF THAT SYSTEM. 2. NO FIRE PROTECTION SYSTEM IS TO REMAIN DEACTIVATED AT THE END OF THE WORK DAY UNLESS AGREED TO WITH THE PROPERTY OWNER, AND A SUITABLE FIRE PROTECTION SCHEME SUCH AS A MANNED FIRE WATCH, HAS BEEN IMPLEMENTED AND APPROVED BY THE OWNER. IT IS THE CONTRACTOR'S RESPONSIBILITY TO SEE THAT ALL FIRE PROTECTION SYSTEMS ARE FILLED, AND THE SYSTEM FUNCTIONAL BEFORE COMPLETING HIS WORK DAY. K. CENTER SPRINKLERS IN ONE DIRECTION ONLY IN CEILING TILE WITH LOCATION IN OTHER DIRECTION VARIABLE, DEPENDENT UPON SPACING AND COORDINATION WITH CEILING ELEMENTS. L. ENSURE REQUIRED DEVICES ARE INSTALLED AND CONNECTED AS REQUIRED TO FIRE ALARM SYSTEM. M. COORDINATE PIPING WITH STRUCTURAL, MECHANICAL PIPING AND DUCTWORK, AND ELECTRICAL WITHIN THE BUILDING. PIPING CONFLICTS BETWEEN SYSTEM SHALL BE REMOVED AND REPLACED AT NO COST TO THE OWNER. N. CONDUCT ALL APPLICABLE TESTS AS REFERENCED IN NFPA STANDARD 13. ALL NECESSARY TESTS SHALL BE CONDUCTED IN CONFORMANCE WITH REQUIREMENTS OF NFPA. 0. SPRINKLER HEAD LOCATIONS ARE FOR REFERENCE ONLY. THE FINAL LOCATIONS NEED TO BE INSTALLED PER CODE AND ARE THE RESPONSIBILITY OF THE CONTRACTOR WHO INSTALLS. P. TENANT FIRE SERVICE MAIN WITH BRANCH PIPING STUBBED INTO TENANT'S SPACE PROVIDED BY LANDLORD. LANDLORD'S SPRINKLER SYSTEM IS DESIGNED PER ORDINARY HAZARD GROUP 2 AND THE LATEST REQUIREMENTS OF NFPA -13. NO ISOLATION VALVES WILL BE PROVIDED OR PERMITTED. Q. CONTRACTOR SHALL CONNECT FIRE SPRINKLER SYSTEM TO LANDLORD SPRINKLER SYSTEM WITHIN THE DEMISED PREMISES USING APPROVED MECHANICAL FITTINGS. CONTRACTOR SHALL PROVIDE AND INSTALL ALL BRANCH PIPING AND SPRINKLERS REQUIRED TO COMPLETE THE SPRINLKER SYSTEM WITHIN THE TENANT SPACE. SPRINKLER SYSTEM DESIGNS SHALL BE BASED UPON THE REQUIREMENTS OF THE STATE OF WASHINGTON, CITY OF TUKWILA FIRE DEPARTMENT. TENANT SHALL ENGAGE THE SERVICES OF A LANDLORD PREFERED FIRE SPRINKLER CONTRACTOR TO DESIGN, PERMIT AND INSTALL TENANT'S FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH THE BASE BUILDING DESIGN SPECIFICATIONS. SPRINKLER LAYOUT AND PIPE SIZING SHALL BE HYDRAULICALLY DESIGNED ACCORDING TO ORDINARY HAZARD GROUP 2 AND THE LATEST REQUIREMENTS OF NFPA -13. TENANT SPACE SPRINKLER SYSTEM WITH 20 SPRINKLER HEADS OR LESS SHALL NOT REQUIRE HYDRAULLIC CALCULATIONS. 15410 PLUMBING FIXTURES AND EQUIPMENT A. MANUFACTURERS: 1. WATER CLOSETS; AMERICAN STANDARD, CRANE, ELJER, KOHLER. 2. LAVATORIES; AMERICAN STANDARD, CRANE, ELJER, KOHLER. 3. ELECTRIC WATER COOLERS; ELKAY, HALSEY TAYLOR, HAWS, OASIS. 4. SERVICE SINKS; FIAT, AMERICAN STANDARD, CRANE, ELJER, KOHLER. 5. FAUCETS (LAVATORIES): AMERICAN STANDARD, CRANE, ELJER, KOHLER, DELTA, MOEN, CHICAGO FAUCET, ZURN. FAUCETS (SERVICE SINKS -): FIAT, MUSTEE, STERN - WILLIAMS, SWAN, CHICAGO FAUCET, ZURN. 7. SEATS: BEMIS, BENEKE, CHURCH, OLSONITE, SPERZEL. 8. CARRIERS: JOSAM, JONESPEC, J.R. SMITH, WADE, ZURN. 9. INSULATION KITS: TRUEBRO, BROCAR, PLUMBEREX SPECIALTY PRODUCTS. 10. RECEPTORS (FLOOR DRAINS, ETC..) JOSAM, J.R. SMITH, WADE, ZURN. 11. FL 0 CLEANOUTS: JOSAM, J.R. SMITH, WADE, ZURN. - 0RIWALL 12. WATER HEATERS (TANK TYPE): A.Q. SMITH, RHEEMIRUUD, STATE. B. PROVIDE BRACKETS, BRACES OR REINFORCING ANGLES AS REQUIRED IN ALL PARTITIONS NOT SUFFICIENT IN THEMSELVES TO SUPPORT PLUMBING FIXTURES OR OTHER WALL -HUNG EQUIPMENT. C. INSTALL EACH FIXTURE WITH CHROME PLATED, 17 GAUGE TUBING TRAP WITH CLEANOUT, EASILY REMOVABLE FOR SERVICING AND CLEANING. D. INSTALL COMPONENTS LEVEL, PLUMB AND SECURE. E. INSTALL AND SECURE FIXTURES IN PLACE WITH WALL CARRIERS AND BOLTS. F. SEAL FIXTURES TO WALL AND FLOOR SURFACES WITH SEALANT, COLOR TO MATCH FIXTURE. G. MCUNT LEVER CONTROL FOR HANDICAPPED WATER CLOSETS ON WIDE SIDE OF TOILET STALL. H. INSULATE WASTE AND SUPPLIES FOR ALL HANDICAPPED FIXTURES. I. ROUGH -IN FIXTURE PIPING CONNECTIONS IN ACCORDANCE WITH MINIMUM SIZES INDICATED IN PLUMBING FIXTURE SCHEDULE ON DRAWINGS. J. REVIEW MILLWORK SHOP DRAWINGS. CONFIRM LOCATION AND SIZE OF FIXTURES AND OPENINGS BEFORE ROUGH -IN AND INSTALLATION. K. EXPOSED WATER PIPING CHROME PLATED BRASS. 15810 DUCTWORK A. PERFORM WORK IN ACCORDANCE WITH SMACNA - HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE, UNLESS MORE STRINGENT REQUIREMENTS ARE NOTED IN LOCAL CODES. B. GALVANIZED STEEL DUCTS: ASTM A525 AND ASTM A527 GALVANIZED STEEL SHEET, LOCK - FORMING QUALITY, HAVING G60 ZINC COATING OF IN CONFORMANCE WITH ASTM A90. C. INSULATED FLEXIBLE DUCTS: 1. MANUFACTURERS: FLEX -AIRE, FLEXMASTER, NORFLEX, THERMAFLEX, WIREMOLD. 2. TWO PLY VINYL FILM SUPPORTED BY HELICALLY WOUND SPRING STEEL WIRE; FIBERGLASS INSULATION; POLYETHYLENE VAPOR BARRIER FILM. PRESSURE RATING: 10 INCHES WG POSITIVE AND 1.0 INCHES WG NEGATIVE. MAXIMUM VELOCITY: 4000 FPM. TEMPERATURE RANGE: -10 DEGREES F TO 160 DEGREES F. D. FABRICATE AND SUPPORT IN ACCORDANCE WITH SMACNA HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE, UNLESS MORE STRINGENT REQUIREMENTS ARE NOTED IN LOCAL CODES. E. INSTALLATION - GENERAL: 1. INSTALL AND SEAL DUCTS IN ACCORDANCE WITH SMACNA HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE, UNLESS MORE STRINGENT REQUIREMENTS ARE NOTED IN LOCAL CODES. 2. SUPPORT DUCTWORK IN ACCORDANCE WITH SMACNA HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE, CHAPTER 4, HANGERS AND SUPPORTS. 3. PROVIDE FIRESTOP SYSTEMS FOR PIPE AND DUCT THROUGH-PENETRATIONS OF THE FOLLOWING FIRE- RESISTANCE -RATED ASSEMBLIES, INCLUDING BOTH EMPTY OPENINGS AND OPENINGS CONTAINING PENETRATING ITEMS: FLOOR AND CEILINGS, WALLS AND PARTITIONS, SMOKE BARRIERS, AND CONSTRUCTION ENCLOSED COMPARTMENTALIZED AREAS. 4. DUCT HANGERS SHALL NOT ATTACH TO BOTTOM CHORD OF STEEL JOIST OR METAL ROOF DECKING. ATTACH TO TOP CHORD OF STEEL JOIST. 5. CONNECT DIFFUSERS OR LIGHT TROFFER BOOTS TO LOW PRESSURE DUCTS DIRECTLY OR WITH 3 FEET MAXIMUM LENGTH OF FLEXIBLE DUCT HELD IN PLACE WITH STRAP OR CLAMP. F. PROTECTION: DURING CONSTRUCTION, PROVIDE TEMPORARY CLOSURES OF METAL OR TAPED POLYETHYLENE ON OPEN DUCTWORK TO PREVENT CONSTRUCTION DUST FROM ENTERING DUCTWORK SYSTEM. G. CLEANING: 1. CLEAN DUCT SYSTEM AND FORCE AIR AT HIGH VELOCITY THROUGH DUCT TO REMOVE ACCUMULATED DUST. TO OBTAIN SUFFICIENT AIR, CLEAN HALF THE SYSTEM AT A TIME. PROTECT EQUIPMENT WHICH MAY BE HARMED BY EXCESSIVE DIRT WITH TEMPORARY FILTERS, OR BYPASS DURING CLEANING. 2. CLEAN DUCT SYSTEMS WITH HIGH POWER VACUUM MACHINES. PROTECT EQUIPMENT WHICH MAY BE HARMED BY EXCESSIVE DIRT WITH FILTERS, OR BYPASS DURING CLEANING. 15820 DUCTWORK ACCESSORIES A. INSTALL ACCESSORIES IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS, NFPA 90A, AND FOLLOW SMACNA HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE. B. INSTALL CONTROL DAMPERS FURNISHED IN SECTION 15906. C. PROVIDE BACKDRAFT DAMPERS ON EXHAUST FANS OR EXHAUST DUCTS NEAREST TO OUTSIDE AND WHERE INDICATED. 15840 VARIABLE VOLUME BOX A. FURNISH ELECTRONICALLY CONTROLLED, FAN POWERED, SINGLE DUCT, VARIABLE VOLUME AIR DISTRIBUTION ASSEMBLIES WITH ATTENUATOR OF THE CAPACITIES LISTED ON VAV SCHEDULE. B. EACH ASSEMBLY SHALL BE PRESSURE INDEPENDENT. THAT IS, IT SHALL PROVIDE AIR FLOW REGULATION WITHIN +/- 50FPM, REGARDLESS OF DUCT PRESSURE FLUCTUATION, THROUGHOUT ITS ENTIRE RATED CFM RANGE. EACH ASSEMBLY SHALL RESET TO ANY AIR FLOW BETWEEN ZERO AND THE MAXIMUM CATALOGED CFM WITHOUT CHANGING ORIFICES OR OTHER PARTS. CFM LIMITERS WILL NOT BE ACCEPTED. C. AT AN INLET VELOCITY OF 2000 FPM, THE DIFFERENTIAL STATIC PRESSURE FOR ANY SIZE SHALL NOT EXCEED 0.15" WG FOR THE BASIC ASSEMBLY, OR 0.45" WITH THE SOUND ATTENUATOR ADDED. D. EACH BASIC ASSEMBLY SHALL CONTAIN AN ACOUSTICAL VORTEX SHEDDER. E. THE AIR DISTRIBUTION ASSEMBLY SHALL BE DESIGNED TO MAINTAIN ESSENTIALLY CONSTANT AIR FLOW REGARDLESS OF INLET FLOW VARIATIONS. A HARD DUCT ELBOW OF ANY ANGLE UP TO 90 DEGREES SHALL NOT ALTER THE MAXIMUM OR MINIMUM FACTORY AIR FLOW SETTING BY MORE THAN 10 %. F. THE ELECTRONIC AIR FLOW SENSOR SHALL BE INDEPENDENT OF DUCT AIR TEMPERATURES FROM 50 TO 120 F OVER A VELOCITY RANGE OF 0 -3000 FPM. G. THE ELECTRONIC CONTROLLER SHALL BE CALIBRATED AND THE FACTORY SET FOR THE MAXIMUM AND MINIMUM AIR FLOW RATES AS SCHEDULED. FIELD CALIBRATION AND READJUSTMENT SHALL BE PROVIDED FOR. THE CONTROLLER SHALL BE FITTED WITH AN EXTERNAL TERMINAL BOARD ON WHICH ALL FIELD CONNECTIONS ARE MADE. ALL TERMINALS SHALL BE CLEARLY LABELED. H. THE ELECTRONIC ROOM THERMOSTAT SHALL HAVE A SET POINT RANGE OF 65 TO 85 F AND A THROTTLING RANGE OF 2 F ± 20 %. I. THE ELECTRIC ACTUATOR SHALL EXERT POSITIVE FORCE IN BOTH THE OPENING AND CLOSING DIRECTIONS; SPRING RETURN TYPES WILL NOT BE ACCEPTED. THE ACTUATOR SHALL INCLUDE BUILT -IN LIMITS TO INTERRUPT THE CURRENT TO THE ACTUATOR AT THE STROKE LIMIT IN EACH DIRECTION. THE ACTUATOR SHALL BE ENERGIZED ONLY WHEN THE CONTROLLER SIGNALS A CHANGE IN DAMPER POSITION. THE ELECTRIC ACTUATOR SHALL BE VARIABLE SPEED, DC CONTROLLED. J. THE AIR DISTRIBUTION ASSEMBLY SHALL OPERATE ON A SINGLE OUTSIDE POWER SOURCE OF 6 WATTS, 60 HERTZ, 24 VOLTS AC + 15 %, -10 %. K. THE ASSEMBLY CASING SHALL BE CONSTRUCTED OF 20 GAUGE GALVANIZED STEEL, INTERNALLY LINED WITH 1 INCH, 1 -1/2 POUND DENSITY FIBERGLASS INSULATION WHICH COMPLIES WITH U.L.. -181 AND NFPA 90A. BOTTOM ACCESS PANEL FOR FAN SERVICE. L. THE DAMPER SHALL BE OF HEAVY GAUGE CONSTRUCTION WITH BLADES PIVOTED IN DELRIN SELF - LUBRICATING BEARINGS. THE BLADES SHALL SEAL WITH LESS THAN 2% LEAKAGE AT 3 INCHES SP, AS RATED BY AIR DIFFUSION COUNCIL TEST CODE 1062 R4. M. BASE BID SHALL BE AS MANUFACTURED BY TITUS, ALTERNATE ADD OR DEDUCT SHALL BE ACCEPTED AS MANUFACTURED BY CARNES. N. FAN SHALL BE CONSTRUCTED OF STEEL AND HAVE A FORWARD CURVED, DYNAMICALLY BALANCED WHEEL WITH DIRECT DRIVE MOTOR. TERMINALS SHALL INCLUDE GASKETTED BACKDRAFT DAMPER AT FAN DISCHARGE TO PREVENT PRIMARY AIRFLOW FROM FLOWING BACK THROUGH FAN SECTION. 15850 AIR OUTLETS AND INLETS A. GRILLES, REGISTERS AND DIFFUSERS: 1. MANUFACTURERS: ANEMOSTAT, KRUEGER, METALAIRE, NAILOR, PRICE, TITUS, TUTTLE & BAILEY. B. GOOSENECKS 1. FABRICATE IN ACCORDANCE WITH SMACNA HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE, OF MINIMUM 18 GAGE GALVANIZED STEEL. 2. MOUNT ON MINIMUM 12 INCH HIGH CURB BASE WHERE SIZE EXCEEDS 9 X 9 INCH. 15906 AUTOMATIC CONTROLS (VAV) A. THE TERMINAL UNIT MANUFACTURER SHALL PROVIDE PRESSURE INDEPENDENT ANALOG ELECTRONIC CONTROLS WHICH CAN BE RESET TO MODULATE AIRFLOW BETWEEN AND THE MAXIMUM CATALOGED CFM. B. THE TERMINAL UNIT SHALL INCORPORATE A MULTI - POINT, CENTER AVERAGING VELOCITY SENSOR. THE SENSOR MUST PROVIDE A MINIMUM DIFFERENTIAL PRESSURE SIGNAL OF 0.03 "WG AT AN INLET VELOCITY OF 500FPM. THE SENSOR MUST PROVIDE CONTROL SIGNAL ACCURACY OF +/ -5 %, WITH THE SAME INLET SIZE AT ANY INLET CONNECTION. C. THE VELOCITY CONTROLLER SHALL HAVE A CONSTANT 2 °F RESET SPAN REGARDLESS OF MINIMUM AND MAXIMUM AIR FLOW LIMITS. THE CONTROLLER SHALL ALLOW FLOW ADJUSTMENTS TO BE MADE AND MONITORED FROM MATCHED THERMOSTAT. IN ADDITION, THE THERMOSTAT SHALL PROVIDE A LIVE VELOCITY READOUT TERMINAL. THE THERMOSTAT SHALL HAVE CONCEALED COVER LATCHES AND TEMPERATURE SETPOINT SLIDERS TO PREVENT TAMPERING. VELOCITY CONTROLLER AND THERMOSTAT ARE BY TERMINAL MANUFACTURER. CONTROL DEVICES SHALL BE FACTORY SET FOR THE SCHEDULED MINIMUM AND MAXIMUM FLOW RATES. VELOCITY MEASURING POINTS WILL BE INTEGRATED WITH THE THERMOSTAT FOR FIELD BALANCING AIRFLOW. ALL PNEUMATIC TUBES SHALL BE UL LISTED FIRE RETARDANT (FR) TYPE. EACH TERMINAL SHALL BE EQUIPPED WITH LABELING SHOWING UNIT LOCATION, SIZE, AND MINIMUM AND MAXIMUM CFM SETPOINTS. E. THE TERMINAL MANUFACTURER SHALL PROVIDE A 24 VAC REVERSIBLE DAMPER ACTUATOR. THE ACTUATOR SHALL BE A DIRECT - COUPLED, SHAFT - MOUNTED TYPE WITHOUT EXTERNAL LINKAGES. A MAGNETIC CLUTCH AND LINKAGE RELEASE BUTTON SHALL BE INTEGRAL TO THE ACTUATOR. THE DAMPER SHALL BE FACTORY SET IN AN OPEN POSITION. F. THE TERMINAL MANUFACTURER SHALL PROVIDE A CLASS 2, 24 VAC CONTROL VOLTAGE _T TRANSFORMER WITH INTERNAL CURRENT LIMITING PROTECTION. ALL CONTROLS SHALL BE INSTALLED IN APPROVED NEMA 1 ENCLOSURE. ALL COMPONENTS MUST BE COMPATIBLE FOR USE WITH GROUNDED CONTROL CIRCUITS PER UL 1995. G. SEQUENCE OF OPERATION: VAV BOX: 1. COOLING CYCLE - OCCUPIED HOURS: UPON A RISE IN SPACE TEMPERATURE ABOVE THE OCCUPIED SETPOINT OF THE THERMOSTAT, THE VAV BOX SHALL MODULATE THE PRIMARY AIR AS REQUIRED TO MAINTAIN SPACE TEMPERATURE AT THE THERMOSTAT SETPOINT. FAN SHALL BE OFF. 2. HEATING CYCLE - OCCUPIED HOURS: UPON A DROP IN SPACE TEMPERATURE BELOW THE OCCUPIED HEATING SETPOINT OF THE THERMOSTAT, THE VAV BOX SHALL MODULATE TO DECREASE PRIMARY AIRFLOW DOWN TO THE MINIMUM AIRFLOW. FAN SHALL BE ON. 3. COOLING CYCLE - UNOCCUPIED HOURS: UPON A RISE IN NIGHT SETBACK SPACE TEMPERATURE ABOVE THE UNOCCUPIED COOLING SETPOINT OF THE THERMOSTAT, THE VAV BOX SHALL MODULATE AS REQUIRED TO MAINTAIN SPACE TEMPERATURE AT THE THERMOSTAT SETPOINT. FAN SHALL BE OFF. 4. HEATING CYCLE - UNOCCUPIED HOURS: UPON A DROP IN NIGHT SETBACK SPACE TEMPERATURE BELOW THE UNOCCUPIED HEATING SETPOINT OF THE THERMOSTAT, THE VAV BOX SHALL MODULATE TO DECREASE PRIMARY AIRFLOW DOWN TO THE MINIMUM AIRFLOW. CYCLE FAN TO MAINTAIN TEMPERATURE SET POINT. 15950 TESTING ADJUSTING, AND BALANCING A. WORK INCLUDES 1. TESTING, ADJUSTMENT, AND BALANCING OF NEW AND EXISTING AIR SYSTEMS. 2. MEASUREMENT OF FINAL OPERATING CONDITION OF HVAC SYSTEMS. B. SERVICES PROVIDED BY QUALIFIED PERSONNEL OF MECHANICAL CONTRACTOR OR INDEPENDENT QUALIFIED TESTING AND BALANCING AGENCY. C. PERFORM TOTAL SYSTEM BALANCE IN ACCORDANCE WITH AABC NATIONAL STANDARDS FOR FIELD MEASUREMENT AND INSTRUMENTATION, TOTAL SYSTEM BALANCE OR NEBB PROCEDURAL STANDARDS FOR TESTING, BALANCING AND ADJUSTING OF ENVIRONMENTAL SYSTEMS. D. VERIFY THAT SYSTEMS ARE COMPLETE AND OPERABLE BEFORE COMMENCING WORK. E. AIR HANDLING SYSTEMS: ADJUST TO WITHIN PLUS OR MINUS 5 PERCENT OF DESIGN FOR SUPPLY SYSTEMS AND PLUS OR MINUS 10 PERCENT OF DESIGN FOR RETURN AND EXHAUST SYSTEMS. ADJUST OUTSIDE AIR TO WITHIN 0 TO PLUS 10 PERCENT OF DESIGN. F. AIR OUTLETS AND INLETS: ADJUST TOTAL TO WITHIN PLUS 10 PERCENT AND MINUS 5 PERCENT OF DESIGN TO SPACE. ADJUST OUTLETS AND INLETS IN SPACE TO WITHIN PLUS OR MINUS 10 PERCENT OF DESIGN. G. ADJUST AIR HANDLING AND DISTRIBUTION SYSTEMS TO PROVIDE REQUIRED OR DESIGN SU .PL RETURN, OUTSIDE AIR, AND EXHAUST AIR QUANTITIES. H. SUBMIT COPIES OF T &B REPORT TO LANDLORD, OWNER, AND ENGINEER. 0 OLOO RECEIVED CITY OF TUKWILA JUL 18 2008 PERMIT CENTER DATE: JOB NO: 07/08/08 DRAWN: MDB CHECKED: SAC 10 u 08- 0196.004 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635 -5696 FAX: (817) 635 -5699 J � co i a � LL4 e 4:t I I- 0 0 p M M �D C7 ' � U f,\ HALLBERG ENGINEERING REVISIONS 1. LANDLORD REVISIONS - 07/10/08 MO- l88 SHEET NUMBER M3 713799 U 1 t .. � Mechanical/Electrical " Cr 1750 Commerce Court, White Bear Lake, MN 55110 (651) 748-1100 • Fax (651) 748-9370 MECHANICAL SPECIFICATIONS outhcenter Branch Relocation Permit I Bid Set -June 20, 2008 HANI 320 Strander Blvd, Tukwila WA Date: .:ODE COMPLIANCE APPROVED 13 1 ° 70H City Of 'N RA DING DDIV FILE COPY Permit NO. Plar review approval Is object to enure and anions. Approval of construction documents does not autheize ap e violation of 1/4 ,;t= o . R iPt BY City of Tukwila BUILDING DIVISION SEPARATE PERMIT REQUIRED FOR ! Mechanical Electrical E /Plumbing E Gas Piping City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. Gensler Architect 1524 Fifth Avenue Suite 300 Seattle WA 98101 Telephone: 206.654.2100 Facsimile: 206.654.2121 PROJECT DESCRIPTION SCALE: 1 : 1 SCALE: 1 /8" =1' -0" CONSTRUCTION OF A NEW ONE STORY BANK BRANCH BUILDING WITH DRIVE THRU CANOPY ON A RETAIL PAD PROJECT INFORMATION BUILDING ADDRESS: 320 STRANDER BLVD, TUKWILA WA BUILDING CODE: 2006 INTERNATIONAL BUILDING CODE(IBC); WITH WASHINGTON STATE AMMENDMENTS OCCUPANCY TYPE: B- OFFICE CONSTRUCTION TYPE: TYPE VA, FULLY SPRINKLERED BUILDING AREA PROPOSED: 7,451 SF (BUILDING) + 4,327 SF (EXT CANOPY) = 11,778 SF TOTAL BUILDING AREA -MAX: 36,167 SF TOTAL PER STORY PROJECT DATUM: FF EL =26' -6" FIRE PROOFING: NONE ZONING: TUKWILA URBAN CENTER (TUC) BUILDING HT- PROPOSED: SINGLE STORY; 20' -0" ABOVE GRADE AT ENTRY BUILDING HT -MAX: 115' -0" SHEETS M00.01 M00.02 MO2.01 MO2.02 M07.01 VICINITY MAP MECHANICAL MECHANICAL LEGEND, ABBREVIATIONS, NOTES & DRAWING INDEX SCHEDULES - MECHANICAL LEVEL 01 CONSTRUCTION PLAN MECHANICAL ROOF PLAN - MECHANICAL DETAILS - MECHANICAL MO' RECEIVED CITY OF TUKWILA JUL 18 2008 PERMIT CENTER SYMBOL xxxxxxx HWS HWR CHWS CHWR CDWS CDWR MPS MPS LPS HPC MPC LPC PC CR RD RS BBD SV I�l t v l A C�4 I OFM -1 VFMT1 PG PG 4T MV � y VB J I I G HP 4IHB FHB L VTR PG EJ FC 0 D R DESCRIPTION NEW WORK EXISTING WORK TO REMAIN EXISTING WORK TO BE REMOVED HEATING WATER SUPPLY HEATING WATER RETURN CHILLED WATER SUPPLY CHILLED WATER RETURN CONDENSER WATER SUPPLY CONDENSER WATER RETURN HIGH PRESSURE STEAM MEDIUM PRESSURE STEAM LOW PRESSURE STEAM HIGH PRESSURE CONDENSATE MEDIUM PRESSURE CONDENSATE LOW PRESSURE CONDENSATE PUMPED CONDENSATE CONDENSATE RETURN REFRIGERANT DISCHARGE REFRIGERANT SUCTION BOILER BLOW DOWN DIRECTION OF SLOPE DIRECTION OF FLOW STEAM VENT PIPE BALL VALVE SOLENOID CONTROL VALVE RELIEF VALVE, P&T RELIEF VALVE BUTTERFLY VALVE MOTORIZED BUTTERFLY VALVE GATE VALVE ANGLE GATE VALVE GLOBE VALVE ANGLE GLOBE VALVE CHECK VALVE PNEUMATIC CONTROL VALVE 2-WAY CONTROL VALVE 3 -WAY CONTROL VALVE NON -SLAM WAFER CHECK VALVE PRESSURE REDUCING VALVE (PRV) DIAPHRAM VALVE LOCK SHIELD VALVE NEEDLE VALVE QUICK OPENING VALVE QUICK CLOSING VALVE, FUSIBLE LINK SQUARE HEAD COCK STRAINER STRAINER WITH BLOW OFF STEAM TRAP AIR LINE AIR SEPARATOR ORIFACE FLOW METER VENTURE FLOW METER PRESSURE GAGE PRESSURE GAUGE WITH COCK AND SNUBBER THERMOMETER PUMP TEST TEE TEST TAP (PE IE'S PLUG) MANUAL AIR VENT AUTOMATIC AIR VENT VACUUM BREAKER VENT THRU ROOF PIPE GUIDE EXPANSION JOINT FLEXIBLE CONNECTOR UNION CAPPED OR PLUGGED TEE BLIND FLANGE, CAP CONCENTRIC REDUCER ECCENTRIC REDUCER EXPANSION LOOP VALVE ON RISE PIPE UP PIPE DOWN PIPE DROP /PIPE RISE TOP CONNECTION -- BRANCH LINE BOTTOM CONNECTION - BRANCH LINE PIPE ANCHOR TEE UP TEE DOWN PIPE SEISMIC BRACE GAS, LOW PRESSURE /HIGH PRESSURE HOSE BIBB GAS COCK CIRCUIT SE I I ER CENTER LINE SYMBOL (DOUBLE LINE) 12x6 VD SPD ED FD 1 Kim A NNW ' -1" BOD 1 OD B F q NECK SIZE -TAG -CFM El NECK SIZE- TAG -CFM NECK SIZE- TAG -CFM Cpl NECK SIZE -TAG -CFM ® NECK SIZE- TAG -CFM NECK SIZE- TAG -CFM ` 1 NECK SIZE - TAG -CFM L - 1 NECK SIZE - TAG -CFM 1 A ww�awMt� ]�• 11111111 < l i p > n lily I FSD AD /AP SIZE CFM TD DESCRIPTION FLEXIBLE CONNECTION FLEXIBLE DUCT RUNOUT TO DIFFUSER DUCT SIZE (WIDTH X DEPTH) DUCT THROUGH BEAM PENETRATION DUCT OFFSET (RISE OR DROP) VOLUME DAMPER SPLITTER DAMPER EXTRACTOR DAMPER FIRE, OR FIRE -SMOKE DAMPER SUPPLY DUCT UP SUPPLY DUCT DOWN EXHAUST DUCT UP EXHAUST DUCT DOWN RETURN DUCT UP RETURN DUCT DOWN CROSS SECTION OF SUPPLY DUCT CROSS SECTION OF EXHAUST AIR DUCT CROSS SECTION OF RETURN AIR DUCT CROSS SECTION OF ROUND DUCT DUCT ELBOW WITH TURNING VANES DUCT ELBOW WITHOUT TURNING VANES ACOUSTICAL LINING DUCT DIMENSION IS ID MOTORIZED DAMPER TRANSFER DUCT (WITH LINER) INDICATES 8'11" TO BOTTOM OF DUCT ROUND OR SQUARE CEILING SUPPLY DIFFUSER (SEE SCHEDULE) 4-WAY THROW UNLESS INDICATED OTHERWISE, ROUND OR SQUARE CEILING EXHAUST REGISTER (SEE SCHEDULE) ROUND OR SQUARE CEILING RETURN REGISTER (SEE SCHEDULE) ROUND OR SQUARE CEILING RETURN GRILLE (SEE SCHEDULE) ROUND OR SQUARE CEILING RETURN GRILLE (SEE SCHEDULE) ROUND OR SQUARE CEILING RETURN GRILLE (SEE SCHEDULE) WALL SUPPLY REGISTER (SEE SCHEDULE) WALL RETURN REGISTER (SEE SCHEDULE) LINEAR SLOT DIFFUSER, "A" INDICATES SIZE SUPPLY AIR LIGHT TROFFER DIFFUSER (TOP CONNECTION, SIDE CONNECTION) DUCT SMOKE DETECTOR ACCESS DOOR / ACCESS PANEL TEMPERATURE SENSING ELEMENT DETAIL 1, DRAWING M -1 SECTION A, DRAWING M-1 EQUIPMENT IDENTIFICATION HEAT PUMP UNIT #1 DELTA SYMBOL (SINGLE LINE) lii HEL___s L- 1 F --12x6 R � D - < ("`. I VD J SD S S /L ED FD FSD g.4 S 4 12x6 J a SIZE TD CFM S 8' -11 "BOD NECK SIZE -TAG -CFM NECK SIZE -TAG -CFM z NECK SIZE -TAG -CFM El NECK SIZE-TAG-CFM l NECK SIZE -TAG -CFM z NECK SIZE -TAG -CFM I NECK SIZE -TAG -CFM NECK SIZE-TAG-CFM A MV AC AD AF AFF AFMS AG AMU AMP AP APPROX ARCH AS AUTO B BBD BHP BHT BMCS BOD BOP BP BSMT BTU BTUH BV BYV C CA CAP CAV CC CEG CER CFM CFS CH CHV CL CLG CO COL CONC COND CONN CP CPF CR CRR CS CSD CTE CU FT CU IN CV CW D DBT DDC DEFL DGP DIA DIFF DN DP OPT DSD DV DWG DX (E) EA EAT) EAT ECON ED EDB EF EFF EJ EL ELEC EMS EQUIP ESP EWBT E EWT EXH EXPT EXT F FC FCU FD FF FLR FPM FPS FSD FT G GA GAL GALV GC GLV GN GPM GRD GV GX HB HC HD HOR HP HPC H PS HR HS HV HVAC HW HWR HWS HX HZ ID IN JB AIR AUTOMATIC AIR VENT AIR CONDITIONING OR AC UNIT ACCESS DOOR AFTER FILTER ABOVE FINISHED FLOOR AIR FLOW MEASURING STATION AIR GAP AIR HANDLING UNIT AMPERE ACCESS PANEL APPROXIMATELY ARCHITECT AIR SEPARATOR AUTOMATIC BOILER BOILER BLOW DOWN BRAKE HORSEPOWER BASEBOARD HEATER BUILDING MONITORING & CONTROL SYSTEM BOTTOM OF DUCT BOTTOM OF PIPE BACKFLOW PREVENTER BASEMENT BRITISH THERMAL UNIT BTU PER HOUR BALL VALVE OR BALANCING VALVE BUTTERFLY VALVE COMMON OR CONDUIT CONTROL AIR CAPACITY CONSTANT AIR VOLUME COOLING COIL CEILING EXHAUST GRILLE CEILING EXHAUST REGISTER CUBIC FEET PER MINUTE CUBIC FEET PER SECOND CHILLER CHECK VALVE CENTERLINE CEILING CLEANOUT COLUMN CONCRETE CONDENSATE CONNECTION CONTROL PANEL OR CONDENSATE PUMP CHEMICAL POT FEEDER CONDENSATE RETURN CEILING RETURN REGISTER CIRCUIT SETTER CEILING SUPPLY DIFFUSER CONNECT TO EXISTING CUBIC FEET CUBIC INCH CONSTANT VOLUME OR CONTROL VALVE COLD WATER DROP OR DRAIN DRY BULB TEMPERATURE DIRECT DIGITAL CONTROL DEFLECTION DATA GATHERING PANEL DIAMETER DIFFERENCE DOWN DIFFERENTIAL PRESSURE DEW POINT TEMPERATURE DUCT SMOKE DETECTOR DIAPHRAGM VALVE DRAWING(S) DIRECT EXPANSION EXISTING EXHAUST AIR OR EACH EXHAUST AIR DAMPER ENTERING AIR TEMPERATURE ECONOMIZER EXTRACTOR DAMPER ENTERING DRY BULB TEMPERATURE EXHAUST FAN EFFICIENCY EXPANSION JOINT ELEVATION ELECTRICAL ENERGY MANAGEMENT SYSTEM EQUIPMENT EXTERNAL STATIC PRESSURE ENTERING WET BULB TEMPERATURE ENTERING WATER TEMPERATURE EXISTING EXHAUST EXPANSION TANK EXTERNAL FAHRENHEIT OR FILTER FLEXIBLE CONNECTION FAN COIL UNIT FIRE DAMPER FINAL FILTER OR FINISHED FLOOR FLOOR FEET PER MINUTE FEET PER SECOND FIRE /SMOKE DAMPER FOOT OR FEET GAS GAUGE, GAGE GALLONS GALVANIZED GAS COCK GLOBE VALVE GENERAL NOTE GALLONS PER MINUTE GROUND GATE VALVE GENERAL EXHAUST HOSE BIB HEATING COIL HEAD HORIZONTAL HORSEPOWER OR HEAT PUMP HIGH PRESSURE CONDENSATE HIGH PRESSURE STEAM HOUR(S) HUMIDITY SENSOR HOSE VALVE HEATING, VENTILATING & AIR COND. HOT WATER HOT WATER RETURN HOT WATER SUPPLY HEAT EXCHANGER FREQUENCY (HERTZ) INSIDE DIAMETER INCH(ES) JUNCTION BOX KW KWH L LAT LBS LDB LF LPC LPS LWBT LWT MA MAD MAX MBH MCC MD MECH MER MFR MIN MPC MPS MV MVD N N A NC NIC NOp NPSH OR # NTS OA OAD OAT OBD OC OD OFM OSA OV PC PD PF PFF PG PH PHC PLBG POC PRESS PRV PS PSI A PSIG PV QTY RA RAD RD REQ'D REV. RF RH RHC RHT RM RPM RS S SA SAD S CFM SF SHC SN SP SPEC SQ IN ST STD STRUCT SV T TCP TD TDH TEMP TI TRG TS IT TX TXV (TYP) UG UON V VAV VB VD VEL VERT VFD VFM VOL VTR W/ W/O WBT WEG WG WP WRR WSR WT XFMR z KILOWATT KILOWATT HOUR LENGTH LEAVING AIR TEMPERATURE POUNDS LEAVING DRY BULB TEMPERATURE LINEAR FEET LOW PRESSURE CONDENSATE LOW PRESSURE STEAM LEAVING WET BULB TEMPERATURE LEAVING WATER TEMPERATURE MOTOR MIXED AIR MIXED AIR DAMPER MAXIMUM THOUSAND BTU PER HOUR MOTOR CONTROL CENTER MOTORIZED DAMPER MECHANICAL MECHANICAL EQUIPMENT ROOM MANUFACTURER MINIMUM MEDIUM PRESSURE CONDENSATE MEDIUM PRESSURE STEAM MANUAL VENT MOTORIZED VOLUME DAMPER NEW NOT APPLICABLE NORMALLY CLOSED NOT IN CONTRACT NUMBER OR NORMALLY OPEN NET POSITIVE SUCTION HEAD NOT TO SCALE OUTSIDE AIR OUTSIDE AIR DAMPER OUTSIDE AIR TEMPERATURE OPPOSED BLADE DAMPER ON CENTER OUTSIDE DIAMETER ORIFICE FLOW METER OUTSIDE AIR OUTLET VELOCITY PUMP OR PRESSURE OR POLE PUMPED CONDENSATE PRESSURE DROP PREFILTER PLUG FOR FUTURE PIPE GUIDE OR PRESSURE GAUGE PHASE (ELECTRICAL) PREHEAT COIL PLUMBING POINT OF CONNECTION PRESSURE PRESSURE REDUCING VALVE PRESSURE SENSOR POUNDS PER SQUARE INCH PSI ABSOLUTE PSI GAUGE PLUG VALVE QUANTITY RISERS OR RELOCATE OR RISE RETURN AIR RETURN AIR DAMPER REFRIGERANT DISCHARGE OR ROOF DRAIN REQUIRED REVISE OR REVISION OR REVOLUTIONS RETURN FAN RELATIVE HUMIDITY REHEAT COIL RADIANT HEATER ROOM REVOLUTIONS PER MINUTE REFRIGERANT SUCTION SUPPLY OR SLOPE SHOCK ABSORBER SEE ARCHITECTURAL DRAWINGS CFM, STANDARD CONDITIONS SMOKE DAMPER SUPPLY FAN SQUARE HEAD COCK (SHEET NOTE STATIC PRESSURE SPECIFICATIONS SQUARE INCH STRAINER OR SOUND TRAP SPLITTER DAMPER OR STANDARD STRUCTURAL STEAM VENT THERMOMETER OR THERMOSTAT TEMPERATURE CONTROL PANEL TRANSFER DUCT TOTAL DYNAMIC HEAD TEMPERATURE TENANT IMPROVEMENT TRANSFER GRILLE TEMPERATURE SENSOR TEST TAP OR TEST TEE TOILET EXHAUST THERMAL EXPANSION VALVE TYPICAL HEAT TRANSFER COEFFICIENT UNDERGROUND UNLESS OTHERWISE NOTED VENT OR VOLT OR VELOCITY VARIABLE AIR VOLUME VACUUM BREAKER VOLUME DAMPER VELOCITY VERTICAL VARIABLE FREQUENCY DRIVE VENTURI FLOW METER VOLUME VENT THROUGH ROOF WASTE OR WIDTH OR WATTS WITH WITHOUT WET BULB TEMPERATURE WALL EXHAUST GRILLE WATER GAUGE WORKING PRESSURE WALL RETURN REGISTER WALL SUPPLY REGISTER WEIGHT TRANSFORMER ZONE 1. CODES AND STANDARDS A. AMERICANS WITH DISABILITIES ACT, (ADA) B. BUILDING CODES ENFORCED BY THE AUTHORITY HAVING JURISDICTION IN WASHINGTON: 1. 2006 INTERNATIONAL BUILDING CODE (IBC) WITH STATE AMENDMENTS. 2. 2006 INTERNATIONAL MECHANICAL CODE (IMC) WITH STATE AMENDMENTS. 3. 2006 UNIFORM PLUMBING CODE (UPC) WITH STATE AMENDMENTS. 4. 2006 INTERNATIONAL FIRE CODE (IFC) WITH STATE AMENDMENTS 5. 2002 NATIONAL FUEL GAS CODE (NFGC) NFPA 54, WAC 51 -52 6. 2005 NATIONAL ELECTRICAL CODE (NEC) 7. 2004 WASHINGTON STATE ENERGY CODE, (WAC 51-11, WSEC) 8. WASHINGTON STATE VENTILATION AND INDOOR AIR QUALITY CODE WA 51 -13 (VIAQ) 2. OUTDOOR DESIGN CONDITIONS A. SUMMER: 83F DB /67F WB ( ASHRAE 0.5% TUKWILA, WA) B. WINTER: 24F (ASHRAE 99.4%, TUKWILA, WA) C, ELEVATION: 40 FT. 3. INDOOR DESIGN CONDITIONS A. ALL AREAS: 1. COOLING 72'F + / -2'F 2. HEATING 68'F + /-2•F B. EXCEPTIONS: 1. ELECTRICAL ROOMS: COOLING ONLY, 78T + / -2'F 2. ATM NER ROOMS: COOLING ONLY, 72'F + / -2'F C. HUMIDITY CONTROL: NONE 4. VENTILATION CRITERIA: A. ALL AREAS: 20 CFM /PERSON B. EXCEPTIONS: 1. RECEPTION AREA: 15 CFM /PERSON 2. WAITING AREA: 15 CFM /PERSON 3. LOBBY: 15 CFM /PERSON 4. CORRIDOR: 0.1 CFM /SQ. FT. 5. STORAGE: 0.1 CFM /SQ. FT. 6. SERVER /COMPUTER ROOMS: 0.15 CFM /SQ. FT, 5. EXHAUST TO OUTDOORS A. TOILET ROOMS: 75 CFM PER WATER CLOSET AND /OR URINALS 6. BUILDING ENVELOPE A. GLAZING: • GLASS /FRAME COMBINATION 1. TYPICAL VERTICAL: a. DESCRIPTION: DOUBLE PANE, LOW -E, THERMAL BREAK FRAME b. U = 0.38 (GLASS ONLY) G. U = 0.43 (WITH FRAME) d. SHADING COEFFICIENT = 0.45 B. WALL CONSTRUCTION: 1. DESCRIPTION: CONCRETE PANEL WITH R-21 BATT INSULATION, METAL STUDS 2. OVERALL U -VALUE = 0.04 C. ROOF: 1. DESCRIPTION: LIGHT COLORED MEMBRANE WITH R -38 INSULATION 2. OVERALL U- VALUE = 0.026 7. INTERNAL HEAT GAIN A. LIGHTING: 1. 1.0 W /SQ. FT. B. RECEPTACLE POWER: 1. 1.5 W /SQ. FT. C. OCCUPANTS: 1. 245 BTUH SENSIBLE BTUH LATENT D. ELECTRICAL TRANSFORMERS: 3% LOSS /50% DIVERSITY E. NER ROOM: 40 W /SQ. FT. F. ATM ROOMS: 25 W /SQ. FT. 8. OCCUPANCY CRITERIA: A. OPEN OFFICE: 1 PERSON /142,8 SQ, FT. B. CLOSED OFFICE: 2 PEOPLE C. RECEPTION AREA: 1 PERSON /16.7 SQ. FT. D. CONFERENCE ROOM: 1 PERSON /20 SQ. FT. E. LOBBY: 1 PERSON /33.3 SQ. FT. 9. DUCTWORK DESIGN CRITERIA A. ALL DUCTWORK: 0.08" W.G. /100 FT. MAX B. MEDIUM PRESSURE SUPPLY 1. 1500 FPM MAX ABOVE CEILING 2. 2000 FPM MAX IN SHAFT C. RETURN VELOCITY: 1500 FPM MAX D. EXHAUST VELOCITY: 1500 FPM MAX A" :; 1 8 2008 1. ALL WORK AND MATERIAL SHALL BE IN ACCORDANCE WITH DIVISION 21, 22, AND 23 SPECIFICATIONS. 2. AS -BUILT RECORD DOCUMENTS: AT PROJECT CLOSEOUT, CONTRACTOR SHALL SUBMIT DETAILED INSTALLATION DRAWINGS, CHANGE ORDERS AND SPECIFICATION CHANGES TO ARCHITECT FOR APPROVAL. REFER TO SPECIFICATIONS FOR ADDITIONAL DETAILS. 3. THE CONTRACTOR SHALL COORDINATE ALL ELECTRICAL CHARACTERISTICS WITH DIVISION 26 ELECTRICAL CONTRACTOR. ALL ELECTRICAL APPARATUS SERVING THE MECHANICAL EQUIPMENT SHALL FULLY COMPLY WITH ELECTRICAL AND CONTROL REQUIREMENTS. 4. OBTAIN WRITTEN PERMISSION OF ARCHITECT BEFORE PROCEEDING WITH ANY CUTTING OR PATCHING OF STRUCTURAL SYSTEMS. 5. PROVIDE THE MANUFACTURERS AND CODE REQUIRED CLEARANCES BETWEEN EQUIPMENT CONTROLS AND BEAMS, PIPES, DUCTS, LIGHT FIXTURES, CONDUITS, WALLS OR OTHER OBSTRUCTIONS, 6. WHERE APPLICABLE, THERMOSTATS SHALL BE ABLE TO: A. MAINTAIN SPACE TEMPERATURE SET POINTS FROM 55 DEGREES TO 85 DEGREES. B. SEQUENCE HEATING AND COOLING AND PROVIDE A 5 DEGREES DEADBAND IN WHICH NO HEATING OR COOLING IS PROVIDED TO THE SPACE. 7. INCLUDE AUTOMATIC SETBACK REQUIREMENTS AS STATED IN SECTION 1432 OF THE WASHINGTON STATE ENERGY CODE. 8. DURING ENTIRE CONSTRUCTION PERIOD, THE CONTRACTOR SHALL MAINTAIN ADEQUATE FIRE EXTINGUISHERS READY FOR USE IN CASE OF FIRE. 9. PROTECTION OF PUBLIC: THE CONTRACTOR SHALL PROTECT THE PUBLIC FROM INJURY DURING PROGRESS OF THE WORK BY POSTING WARNING SIGNS, GUARD LIGHTS AND BARRICADES. 10. FURNISH AND INSTALL MATERIALS, EQUIPMENT AND LABOR AS SHOWN AND AS NECESSARY FOR COMPLETE WORKABLE SYSTEMS. 11. RESTORE ALL DAMAGE RESULTING FROM YOUR WORK AND LEAVE PREMISES IN CLEAN CONDITION WHEN FINISHED WITH WORK. 12. NO PENETRATIONS ALLOWED IN DUCTS. 13. COMPLETION AND COMMISSIONING FOR MECHANICAL SYSTEMS, A. RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER WASHINGTON STATE ENERGY CODE (WSEC) SECTION 1416.1, B. AN OPERATING AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER PER WSEC SECTION 1416.2. C. ALL HVAC SYSTEMS SHALL BE BALANCED BY AN INDEPENDENT NEBB OR AABC CERTIFIED TAB AGENCY. A WRITTEN BALANCE REPORT SHALL BE PROVIDED TO THE OWNER PER WSEC SECTION 1416.3. D. HVAC CONTROL SYSTEMS SHALL BE TESTED, CALIBRATED AND ADJUSTED. SEQUENCES OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORD WITH SPECIFICATIONS AND APPROVED PLANS PER WSEC SECTION 1416.4.2, NECESSARY TESTS SHALL BE IDENTIFIED PER WSEC SECTION 1416.4.2.1. A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURE AND RESULTS SHALL BE PREPARED PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY PER WSEC SECTION 1416,4,2.2,1 AND 1416.4,2,3. A COMPLETE FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE FILED WITH THE OWNER PER WSEC SECTION 1416.4.2.2.2. E. A SINGLE LINE DIAGRAM SHOWING DISCREPANCIES BETWEEN (E) PLANS & SITE CONDITIONS (THERMOSTAT LOCATIONS, DUCT /GRILLE /EQUIPMENT LOCATIONS ETC) SHALL BE PROVIDED TO GLUMAC UPON COMPLETION OF CONSTRUCTION. M00.01 M00.02 MO2.01 MO2.02 M07.01 MECHANICAL LEGEND, ABBREVIATIONS, NOTES, AND DRAWING INDEX SCHEDULES - MECHANICAL LEVEL 01 CONSTRUCTION PLAN - MECHANICAL ROOF PLAN - MECHANICAL DETAILS - MECHANICAL ICAL D Kn T N ( - T r , / I I iI 1$'1 08 PERMIT CENTeR S �� t fet .0 } iE Southcenter Branch Relocation 320 Strander Blvd Tukwila, WA 98188 SERIAL NUMBER: NRSP VERSION: INCLUDES BULLETIN: Gensler Architecture, Design & Planning Worldwide r LU M A e ngineers for a sustainable future"' L .1 1325 Fourth Ave, Suite 1515 Seattle, WA 98101 1'. 206.262.1010 F. 206.262.9865 Rev Issue Date & Issue Description By Check 02/13/2008 Design Development MA / TM SPV / MAJ 04/30/2008 CD Owner Review MA / TM SPV 1 MAJ 06/20/2008 Permit / Bid Set MA I TM SPV / MAJ SeallSignature Project Name SEAL OF G ENGINEERING QUAUTY Proloke Dept Project Maragcr load Faginew Southcenter Branch Relocation Job No.: 507023GEN Contact: Michael Aliaga www.glumac.com WA0049 2.0 21A 1524 Fifth Avenue Suite 300 Seattle, WA 98101 Telephone 206.654.2100 Facsimile 206.654.2121 I EXPIRES 03-24-10 a 2 a. 0 LO co 0 N 0 N 0 0 I- 0 0 CO z w 47 0 r~ 0 tn 0 0 i r< 0 0 N Project Number 32.2177.089 Description Mechanical Legend, Abbreviations, Notes, and Drawing Index Scale M00.01 ? 2006 Gensler