HomeMy WebLinkAboutPermit M08-190 - BANK OF AMERICABANK OF AMERICA
320 STRANDER BL
M08 -190
Parcel No.: 6364200010
Address:
Suite No:
Tenant:
Name:
Address:
Owner:
Name:
Address:
320 STRANDER BL TUKW
CitAf Tukwila
BANK OF AMERICA
320 STRANDER BL , TUKWILA WA
WESTFIELD PROPERTY TAX DEPT
PO BOX 130940 , CARLSBAD CA
Contact Person:
Name: BRIAN VAN STIPDONK
Address: 1200 6 AV, STE 500 , SEATTLE WA
Value of Mechanical: 155,900.00
Type of Fire Protection:
Furnace: <100K BTU 0
>100K BTU 0
Floor Furnace 0
Suspended/Wall/Floor Mounted Heater 0
Appliance Vent 0
Repair or Addition to Heat/Refrig /Cooling System.... 0
Air Handling Unit <10,000 CFM 5
>10,000 CFM 0
Evaporator Cooler 0
Ventilation Fan connected to single duct 1
Ventilation System 0
Hood and Duct 0
Incinerator: Domestic 0
Commercial/Industrial 0
doc: IMC -10/06
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tuicwila.wa.us
Contractor:
Name: OKITSU CONSTRUCTION INC.
Address: 1428 WHITWORTH AV S , RENTON WA
Contractor License No: OKITSCI959L8
MECHANICAL PERMIT
EQUIPMENT TYPE AND OUANTITY
* * continued on next page **
M08 -190
Permit Number:
Issue Date:
Permit Expires On:
Phone:
Phone: 206 654 -2129
Phone: 206 714 -9969
Expiration Date: 06/28/2009
DESCRIPTION OF WORK:
MECHANICAL FOR NEW STAND ALONE BUILDING: PACKAGED ROOFTOP UNITS WITH GAS HEAT.
EACH UNIT WILL INCLUDE SUPPLY FAN, GAS FURNACE, DIRECT EXPANSION (DX), COOLING
COIL, MERV 8 FILTERS, AND FULL AIR -SIDE ECONOMIZER.
M08 -190
12/09/2008
06/07/2009
Fees Collected: $1,726.25
International Mechanical Code Edition: 2006
Boiler Compressor:
0 -3 HP /100,000 BTU 0
3 -15 HP /500,000 BTU 0
15 -30 HP /1,000,000 BTU.. 0
30 -50 HP /1,750,000 BTU.. 0
50+ HP /1,750,000 BTU 0
Fire Damper 0
Diffuser 0
Thermostat 5
Wood/Gas Stove 0
Water Heater 0
Emergency Generator 0
Other Mechanical Equipment
Printed: 12 -09 -2008
Permit Center Authorized Signature:
doc: IMC -10/06
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Permit Number: M08 -190
Issue Date: 12/09/2008
Permit Expires On: 06/07/2009
Date: () 'V 0
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permi does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the perfo ance / f work. I am authorized to sign and obtain this mechanical permit.
Signature: 0 Date: 1 / 61 - 9-
Print Name:
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
M08 -190 Printed: 12 -09 -2008
Parcel No.: 6364200010
Address:
Suite No:
Tenant:
doc: Cond -10/06
BANK OF AMERICA
1: ** *BUILDING DEPARTMENT CONDITIONS * **
11: ** *FIRE DEPARTMENT CONDITIONS * **
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
320 STRANDER BL TUKW
PERMIT CONDITIONS
Permit Number:
Status:
Applied Date:
Issue Date:
M08 -190
ISSUED
07/18/2008
12/09/2008
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: Readily accessible access to roof mounted equipment is required.
6: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
7: Manufacturers installation instructions shall be available on the job site at the time of inspection.
8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila
Permit Center.
9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
12: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned
in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051)
13: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be
equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the
air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors
shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the
manufacturer's installation instructions. (IMC 606.1, 606.2.1)
14: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051)
15: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051)
M08 -190 Printed: 12 -09 -2008
doc: Cond -10/06
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
17: Local U.L. central station supervision is required. (City Ordinance #2051)
* * continued on next page **
16: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire
Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC
104.2)
18: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and
#2051)
19: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70)
20: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed
description of intended use.
21: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of
such condition or violation.
22: These plans were reviewed by Inspector 0700. If you have any questions, please call Tukwila Fire Prevention Bureau at
(206)575 -4407.
M08 -190 Printed: 12 -09 -2008
Signature:
Print Name:
doc: Cond -10/06
4 00 9 .A e y
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating
construction or the performance of work.
Date: / 4 q - q8
M08 -190 Printed: 12 -09 -2008
SITE LOCATION
!
Site Address:
Tenant Name:
Property Owners Name:
Mailing Address: g
CITY OF TUKWILA
Community Development Department
Permit Center
6300 caL;thcenter Blvd., Suite 100
Tukwila, WA 98188
i'ato:.Ywww el, tukwilawa.24
r cp,NTACT,PERSON --iiho do4e ctin6ct %s:lien .oar erieli • " d r 6' • . - •-• • t .4 - ' • - '''''''. ''''
1 ...„:,:. ,. ...,,„..,, .., .:.., . _:. 0:. p S I ey. o be Issud.t . .. .4... . . r p.. . ..
r .,. . .., .'. . , , - . ' -.: • ' . .-. .. , !:P ' - u....
Name: 3(11 4, pel ie Day Telephone: 2_04 (Tft Zi Z.1
Mailing Address: t2;.)0 41/ AVC .,/i 4 ,<, 5 el 4-t k
t..,A
; City State ziapi
I ••••• — V L6.5 If" C-fh'''''' V , Fax Number:
E-Mail Address:
1 MECTIANICAL.CONTRA.crogINFoRiviAltoN --, ‘: -- , ..... ,., .r.. ' lei3,
I. :4.— " '' ' l'• ' ' + ,7 ' ■ ' ,;1 a ' .. r ' ' '', ' • 4 ., ' ' , ' '' . ' ..
,.:
Company Name:
Mailing Address:
T 0
Contact Person:
E-Mail Address:
Contractor Registration Number:
Company Name:
4 ) 1 .App 1 ■estions ,, Forrns-Applications Oa Line:3.204e - Mechanical Paint! Application 4,,c
v.5ed
hit
• or
MECIIA.NICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print* *
4rAndse thi
C
z
:
JO'N
1d5 j A 9
City late
1.-iSzt161.te__
ZOO 1 AIC 3.1 500
Mailing Address: t
ENGINEER OF RECORtc.:-0piaiii nii.tt be vykstaid byEritinei-0
e
I7 • • • - •
Nteehaiii0.2.1 Permit No.
Project No MV
or o co ris:e only)
••••••■••••■■■■■
_ • ..
••
np• • - • •• • '7:: '
, • . •
• • _
King Co Assessor's Tax No.:
Suite Number:
New Tenant: /c1 .... Yes D..fo
City
Day Telephone:
Fax Number:
Expiration Date:
State
ARCOITECT. OF RECORif-ifAIIplaiis..muit .-Aife'l Record
'
Z i p
Zi
City State Zip
Contact Person: r: 0 OVA
, Day Telephone: X 6- ( 2.1
E-Mail Address: . rt e V 6D, tig e Fax Number:
Company' Name:
Mailing Address: 1)2-T A AVN Ave_ t, e Icic" .eel-i-f-ft LiA, cit id I
City
State Zip
.
Contact Person: l -fryirA Al ‹)e, . Day Telephone: ZO C. 24,2, 010
E-Mail Address: I'M 1 31 , j ‘( 3 limn 4.L..,g....b-N Fax Number: ZO C. 2z (II:CT
Page 1 of 2
Date Application Accepted: a
J
Date Application Expires:
Qty
Sl tf f Initials:
(�
11
Qty
Ot t (3 I 9 �
Unit Type:
Qty
nit Type:
Qty
-Unit T e
Yp .
Qty
Boi1erlComp'ressor:
Qty
Furnacc<100K UTU
Air andling nit > I0,000
CFM
I
Fire Damper
0-3 HP 100,000 BTU
/
Furnace >l01K B'fU
I$I
Eva orator ' oler
WJJ
D ' iser
p .r ,
-15'1IPt500,000 B'1i.
1!
F1oorFurnace
Ventilation Fan Connected
to Single Duct
Thermostat
15- 301IP /1,000, 13
Suspended/lrall/Floor
Mounted heater
MI
Ventilation System
Hood and Duct
)
Val
Wood/Gas Stove
Water' Heater
I
30 -50 HP!1.750,0001311J
50* II:/1,750,0 STU
f
101
Ap Vent
Repair or Addition to
Hent/RefrigiCooling
System
(
nctnerator - Domestic
Y'
Y'
Emergency
Generator
T
r Air Handling Unit
<10,000 CFM
Incinerator — Comm /Ind
,�
Other Mechanical
Equipment
Valuation of Project (contractor's bid price): s 100
Scope of Work (please ravide detailed information): Tile l „! # } } be p�^;� t CO
I'{i t4r-e
� "mi
' L, i r---5; liy e (yy t' .of.
Use: Residential: New ....❑ Replacement ....
Commercial: New ... Replacement .... ❑
BUILDING 0
Signature:
Print N
Mailing Address:
Fuel Type: Electric ❑ G
Fgt.: APV;ICATI a „ -fit
AUTHORIZE
0 1APplienti nsW.rru.Applie, ism on Uno3.a006 • f,leehatrcal Permit Applka[bn don
ItsvlaN 4 "2(Kl,
th
Other
Indicate type of mcchanicai work being installed and the quantity below:
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
.Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
1 he Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested
in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS. APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
Date:
69 /
Day Te leh
p one: `1!v V0 �'— Q Vb
r0 c74 4 /0° 3
City state Zip
Page 2of2
n....• pprcr c_rm
RECEIPT NO: R08 -02643
Initials: JEM
User ID: 1165
Payee: GENSLER
SET ID: S000001082
SET TRANSACTIONS:
Set Member Amount
EL08 -1018
HMO8 19Q
PG08 -210
TOTAL:
TRANSACTION LIST:
Type Method
Payment
ACCOUNT ITEM LIST:
Description
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: //www.ci.tukwila.wa.us
4,340.00
1,726.25
582.00
6,648.25
ELECTRICAL PERMIT - NONR
ELECTRICAL PLAN - NONRES
GAS - NONRES
MECHANICAL - NONRES
PLAN CHECK - NONRES
PLUMBING - NONRES
Description
Check 110577
SET RECEIPT
TOTAL:
Payment Date: 07/18/2008
Total Payment: 6,648.25
SET NAME: Tmp set/Initialized Activities
Amount
6,648.25
6,648.25
Account Code Current Pmts
000.322.101.00.0 3,472.00
000.345.832.00.0 868.00
000.322.103.00.0 90.00
000.322.102.00.0 1,381.00
000/345.830 421.25
000.322.103.00.0 416.00
TOTAL: 6,648.25
017 07/18 9716 TOTAL 66/03.25
Proje � ar aitACl•JTYP?Off��3
do : S14
Address: '2 ` S lq A-k Z r
�--/
Date eS _ A `^ 4
Special Instructions:
03 tS 9C` O ('Z'
� A ' 8 ``' A
`.+
Date Wanted: ,- f? ij 9
/ (
rape
p.m.
Requester:
Phone No:
2Q - ' 5
) 7
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION le-
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
nee �r l.� � � (-eX-
I
SJ P rbJ - A. 44-
Afpf o _
ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
4
COMMENTS:
Type of Inspection:
)- -I, /
4 ,I
h,xv/ , 1.7 4 7-A / / - fv. 9 xi ,-. .-
2/4,; & a1/ ide, 17k' dai¢a 7'G S PC.v'°
4
/2 , ‘> A-
1- / -
d,%.,5/,-'7' %/19---e--
- ,2/# i0
Requester:
Phone No:
_ 0C- ;f..?-z
Ne
--� ..
N
Proj ct:
. Ate. of 4,9G47»'4
Type of Inspection:
)- -I, /
Address:
3L0 Sr1?Al/Op
a
Date Called:
Special Instructions:
Date Wanted:
2 _ 6 9
p.m.
Requester:
Phone No:
_ 0C- ;f..?-z
G/
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
lnsp
r:
INSPECTION RECORD
Retain a copy with permit
m0,° - /9v
PERMIT NO.
I4
(206)431 -3670
El Approved per applicable codes. Corrections required prior to approval.
D>re---: 2 ._
$60.00 REINSPECTION FE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter B vd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
COMMENTS:,
d
Type cA Ins ectii n:
Adcirrei :n sTrQ
( r c(- 76^-S MA
a fr • - 0 (-r
,S , ) -P Act ,r4
(1
AW /4 It Bo: (6Q,,,
----- ti i. 1 t
_St
( e C-1 t hel.
g
Requester:
_
Phone No:
/AO I0- '71°3
-
25
.-----., f\
1 (
Pro e t: 31-
d
Type cA Ins ectii n:
Adcirrei :n sTrQ
StiA
Date Called:
Special Instructions:
/
Date Wanted:
-5-
g
Requester:
Phone No:
/AO I0- '71°3
-
25
INSPECTION RECORD
Retain a copy with permit
M0$
rERMIT NO.
CITY OF TUKWILA BUILDING DIVISION (
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36
INSPECTION NO.
A pproved per applicable codes. Corrections required prior to approval. 7
r V `Date: -eV'Oy
El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Inspect'; r:
Receipt No.:
Date:
COMMENTS: p 4 .
�/}
..„ RAI b - •../ / 4 1 / 1 04 g O 7' At ' _ 4 5
e ' ¢fir sr Cif s %rte .. i s i so„/ /¢ Q a ; A l .& c
Address:
.3Lo •S T,Qit a/vQ
Date Called:
)
/?- -- -9 -0.- 09 - / / �}','- /�t/er-
7
- � '
�v
' A/ D Tie' % ,�aaa� /�f /" /.%7 Ai L / Q
Requester:
/ r4
! /
AtA
.4,ve z , r/mur/ tor✓ i ;e2r --
.
f1 /).\\,
2ro ct:
li A,t/K v F #1,v/'e --
Type of Inspection:,
AZ rn,C 4 --/iv
Address:
.3Lo •S T,Qit a/vQ
Date Called:
Special Instructions:
Date Wanted:
— / 8_. dq
p.m.
Requester:
Phone No:
Ok 06 -7.13 _2.5.4.,y,
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
A. El per applicable codes.
Corrections required prior to approval.
e pector
I Date., ^ ,
k
.00 REINSPECTION FEE R EQUIRED. Prior to inspection, fee must be
aid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
ceipt No.:
Date:
i
Project:
v /9-
Type of Inspe tion:
/.Z e� /5i —
Address:
37- D S T /2AN�,x,-
Date Called:
f
Special Instructions:
Date Wanted:
5-- 5
— 0 , s
a.m.
p.m.
Requester:
Phone No:
/hee—/F0
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Approved per applicable codes. Ei Corrections required prior to approval.
COMMENTS: p
/20t,t7 --`•./ - 4,,hir.d.,,z/Ariaikttes
V
i/1
j L
l
0 .00 REINSPECTION F REQ RED. Prior to inspection, must be
. id at 6300 Southcenter :,vd., uite 100. Call to schedule reinspection.
f Re eipt No.:
Date:
MEMORANDUM
Date: August 1, 2008
To: Barry Zimmerman
Company Gensler
1200 Sixth Avenue, Suite 500
Seattle, WA 98101
206 -654 -2129
C:
Narrative:
End of Narrative
1601 Fifth Avenue, Suite 900 • Seattle, Washington • 98101
(206) 623 -0717 Phone (206) 624-3775 FAX
,LAS Gs- creativity:I results J relationships !'
A EOFFMAN
Project: B of A South Center
3XX Strander BI
Tukwila WA
Project No.: 08040 ptmi. e
From: Arvind Nerurkar
1. Permit #M08 -190
Regarding item 1 in the Determination of Completeness Memo, Structural framing members
supporting mechanical units at the roof have been determined to adequately resist gravity and
lateral induced loads. See attached supporting calculations on sheet MF -7 and detail 1 on sheet
MF -8 for further clarification.
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 18 2008
City Of Tukwila
BUILDING DIVISION
INCOMPLETE
LTR # �_
11O9. 190
RECEIVED
AUG 052008
PERMIT CENTER
s-
CH Eex Zoo; •g`i 4 g Mui-i vAia
R2
C v'tog -S Cyst
Y Ig 210 1 65 2 5 S6
v1141 2 100 /(z + /44
v.l1L t- 3A- pLF
1 4412 = • 5l).? Lev' r'-i
v� L 11
ui/ F 1 v 312
LATE RA-L
P
9U
L65
= S.g3 FLt=
IR ?1,1. ■/M■ <
1 f
If
T ` 903 x 49 zoite3 utk= 6(9%1-
I 03E 3/ SDS ScRiv -13
ecA cca
t . t4q
r■
\- . .;p 1
0 0 :1sb 2t00 (
S.Z
uloR_,FT
A COFFMAN
N G I N E E R S
prole« 5 F A < , i) L,NTI sa
location (i/ K �,(i t / w { A
client 61
by d
date k
checked
date
sheet no
F -
job no.
6t646
(4) If u 3 / SD
EA Cok.N C:k
l3l aC k k nJG1
A S k A TK?
0 )4 LeA AN k c,4 L //DD F
A
A x 4 6 t 3 LIC.tNG —,
>4� to , Eb�zr S
ALCOFFM�4N
N G I N E E R S
Project /),:: l4 So v rF /6_,Ai C PZ..
location (✓ vi A-
dient en r ,jZ
by S4
date (t /
checked
date
sheet no.
MF -
job no.
O4
•.b
MINE
36 c9'A
6PRP�G 78
(3
4 4• cm46
Ce
qe.
fic5
Figure 18.
Roof Curb
* All dimensions are In Inches /millimeters.
Dimensional Data
csl Nb
Cooling with Optional Electric Heat and Gas /Electric Models - 6-10 Tons
Standard and High Efficiency
C(411:4431,4,_ q '`'c 06.
Ie. r
f
89 7/8' 4 a .
(scsomm) ) . Op
ALL FLANGES 1 1/4" (31 MM)
Figure 19. Cooling with Optional Electric Heat and Gas /Electric Models
6-10 Tons - Downflow Duct Connections Field Fabricated
* All dimensions are in Inches /millimeters.
(RTU -R.2.
O,p y
RT- PRCO25 -EN 125
Cooling Equipment Schedule
Equip.
ID
Brand Name'
Model No.'
Capacity
Btu/h
Total CFM
OSA CFM
or Econo?
SEE�ZIC
�l�
Kopp,
�l! ctl o n
Tukwilla, WA 98188
Applicant Name:
clumac, Michael Aliaga
�
COP
CITY
p����
I
Applicant Phone:
206- 262 -8375 r
Ali .
MOt
Jill
A
i v
1 8
8
vutiviIT CENTER
CO
Of 75 ��a
,',
Fan Equipment Schedule
Equip.
ID
Brand Name'
Model No.'
CFM
SP'
HP /BHP
Flow Control
Location of Service
Equip.
ID
Tukwilla, WA 98188
Applicant Name:
clumac, Michael Aliaga
�
COP
CITY
RECEIVEC
VF i UKW1L.PI
/NS
Applicant Phone:
206- 262 -8375 r
Ali .
MOt
Jill
18 2C08
Heating
Equipment Schedule
Brand Name'
Model No.'
Capacity
Btu/h
Total CFM
OSA cfm
or Econo?
it „pi
Input Btuh
t1 Div
Output Btuh
Efficiency`
Equip.
ID
Tukwilla, WA 98188
Applicant Name:
clumac, Michael Aliaga
�
COP
CITY
RECEIVEC
VF i UKW1L.PI
/NS
Applicant Phone:
206- 262 -8375 r
Ali .
Jill
18 2C08
vutiviIT CENTER
Project Info
.
Project Address
BoA- Southcenter Branch Relocation
Date
320 Strander Blvd.
For Building Dept. Use
Tukwilla, WA 98188
Applicant Name:
clumac, Michael Aliaga
�
COP
Applicant Address:
1325 4th Ave. Seattle, WA 98101
/NS
Applicant Phone:
206- 262 -8375 r
Ali .
II. £ Y Y••I
Mechanical Summary
►•Y - •-Y - _Y • .• •11} . • 11
MECH -SUM
2006 Washington State Nonresidential Energy Code Compliance Forms
Project Description
Briefly describe mechanical
system type and features.
Indudes Plans
Building will be conditioned with packaged rooftop,lmitwi full a
economizers.
Drawings must contain notes requireing compliance with commissioning requirements - Section 1416
•
Revised July 2007
Compliance Option
Q Simple System 0 Complex System O Systems Analysis
(See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.)
Equipment Schedules
The following information is required to be incorporated with the mechanical equipment schedules on the
plans. For projects without plans, fill in the required information below.
'If available. 2 As tested according to Table 14 -1A through 14-1G. 3 If required. ` COP, HSPF, Combustion Efficiency, or AFUE, as applicable.
5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS).
System Description
If Heating/Cooling
51
Constant vol?
Q Air cooled? 5 Packaged sys? ■ <20,000 Btuh?
See Section 1421 for full description of
Simple System
or Cooling Only:
Split system?
•
Q Economizer included?
qualifications.
If Heating Only:
9 M
�
5000 cfm?
<5000
� <70 /o outside air?
<70%
1,. 1 • 1 1• 01 • \•1 - 11 "1 • _1 • ••- •11} .1: • 11
, Mechanical Summary (back)
MECH -SUM,
Decision Flowchart
Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex
System or Systems Analysis Options must be used.
( START )
otal Ca
wo economize
<240,000 Btuh
or 10 %?
Heating Only
Reference
Section 1421
Heating/Cooling
or Cooling Only
Simple System
# Allowed
(section 1420)
I Reference
Section 1423
Complex Systems
I Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex
Systems requirements are applicable to this project.
Mechanical Permit Plans Checklist
2006 Washington State Nonresidential Energy Code Compliance Forms
MECH -CHK
Revised July 2007
Project Address BoA-Southcenter Branch Relocation
'Date
The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the
Washington State Nonresidential Energy Code.
Applicability
(yes, no, n.a.)
Code
Section
Component
Information Required
Location
on Plans
Building Department
Notes
HVAC REQUIREMENTS (Sections 1401 -1424)
1411
Equipment performance
yes
1411.4
Pkg. elec. htg.& clg.
List heat pumps on schedule
M00.02
yes
1411.1
Minimum efficiency
Equipment schedule with type, capacity, efficiency
moo. 02
n.a.
1411.1
Combustion htg.
Indicate intermittent ignition, flue/draft damper & jacket loss
1412
HVAC controls
yes
1412.1
Temperature zones
Indicate locations on plans
MO2.01
yes
1412.2
Deadband control
Indicate 5 degree deadband minimum
Moo .01
n.a.
1412.3
Humidity control
Indicate humidistat
yes
1412.4
Automatic setback
Indicate thermostat with night setback and 7 diff. day types
Moo .02
n.a.
1412.4.1
Dampers
Indicate damper location and auto. controls & max. leakage
yea
1412.4.2
Optimum Start
Indicate optimum start controls
M00.02
n.a.
1412.5
Heat pump control
Indicate microprocessor on thermostat schedule
n.a.
1412.6
Combustion htg.
Indicate modulating or staged control
yes
1412.7
Balancing
Indicate balancing features on plans
MO2.01
1412.8
Ventilation Control
Indicate demand control ventilation for high - occupancy areas
n.a.
1422
Thermostat interlock
Indicate thermostat interlock on plans
yes
1423
Economizers
Equipment schedule
M00.02
1413
Air economizers
yes
1413.1
Air Econo Operation
Indicate 100% capability on schedule
Moo .02
n.a.
1413.1
Wtr Econo Operation
Indicate 100% capacity at 45 degF db & 40 deg F wb
n.a.
1413.2
Water Econo Doc
Indicate clg load & water econoe & clg tower performance
yes
1413.3
Integrated operation
Indicate capability for partial cooling
M00.02
n.a.
1413.4
Humidification Indicate direct evap or fog atomization w/ air economizer
1414
Ducting systems
yes
1414.1
Duct sealing
Indicate sealing necessary
M00.02
yes
1414.2
Duct insulation
Indicate R -value of insulation on duct
Moo . 02
yes
1415.1
Piping insulation
Indicate R -value of insulation on piping
m00.02
1416
Completion Requirements
yes
1416.2.1
Commissioning
Provide commissioning plan
Moo . 01
yes
1416.2.2 -3
Sys.Bal & Func.Test
Indicate air and water system balancing & functional testing
M00.01
yes
1416.2.4
Commissioning
Indicate O &M manuals, record drawings, staff training
M00.01
yes
1416.2.5
Comm. Report
Indicate requirements for prelim. & final commissioning report
M00.01
yes
1434
Separate air sys.
Indicate separate systems on plans
MO2.01
yes
Mechanical
Summary Form
Completed and attached. Equipment schedule with types,
input/output, efficiency, cfm, hp, economizer
M00.02
SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454)
1440
Service water htg.
n.a.
1441
Elec. water heater
Indicate R -10 insulation under tank
yes
1442
Shut -off controls
Indicate automatic shut -off
P00.1
yes
1443
Pipe Insulation
Indicate R -value of insulation on piping
P00. 1
n.a.
1452
Heat Pump COP
Indicate minimum COP of 4.0
yes
1452
Heater Efficiency
Indicate pool heater efficiency
M00.02
n.a.
1453
Pool heater controls
Indicate switch and 65 degree control
n.a.
1454
Pool covers
Indicate vapor retardant cover
n.a.
1454
Pools 90+ degrees
Indicate R -12 pool cover
2006 Washinton State Nonresidential Energy Code Compliance Form
2006 Washin•ton State Nonresidential Ener. Code Corn liance Form
Mechanical Permit Plans
Checklist
MECH CHK
2006 Washington State Nonresidential Energy Code Compliance Forms
Revised July 2007
Mechanical - General Requirements
1411.1 General: Equipment shall have a minimum performance at the specified
rating conditions not less than the values shown in Table 14-1A through 14-1G. If a
nationally recognized certification program exists for a product covered in Tables
14-1A through 14-1G, and it includes provisions for verification and challenge of
equipment efficiency ratings, then the product shall be listed in the certification
program.
Gas -fired and oil -fired forced air furnaces with input ratings? 225,000 Btu/h (65
kW) and all unit heaters shall also have an intermittent ignition or interrupted device
(IID), and have either mechanical draft (including power venting) or a flue damper. A
vent damper is an acceptable alternative to a flue damper for furnaces where
combustion air is drawn from the conditioned space. All furnaces with input ratings >
225,000 Btu/h (65 kW), including electric furnaces, that are not located within the
conditioned space shall have jacket losses not exceeding 0.75% of the input rating.
1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions
and procedures when available. Where no applicable procedures exist, data shall
be furnished by the equipment manufacturer.
1411.3 Combination Space and Service Water Heating: For combination space
and service water heaters with a principal function of providing space heat, the
Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard
124 -1991. Storage water heaters used in combination space heat and water heat
applications shall have either an Energy FActor (EF) or a CAE of not less than the
following:
1411.4 Packaged Electric Heating and Coo ing Equipment: Packaged electric
equipment providing both heating and cooling with a total cooling capacity greater
than 20, Btu/h shall be a heat pump.
Exception: Unstaffed equipment shaelters or cabinets used solely for
personal wireless service facilities.
1412 Controls
1412.1 Temperature Controls: Each system shall be provided with at least one
temperature control device. Each zone shall be controlled by individual thermostatic
controls responding to temperature within the zone. At a minimum, each floor of a
building shall be considered as a separate zone.
1412.2 Deadband Controls: When used to control both comfort heating and
cooling, zone thermostatic controls shall be capable of a deadband of at least 5
degrees F within which the supply of heating and cooling energy to the zone is shut
off or reduced to a minimum.
Exceptions:
1. Special occupancy, special usage, or code requirements where
deadband controls are not appropriate.
2. Buildings complying with Section 1141.4, if in the proposed building
energy analysis, heating and cooling thermostat setpoints are set to
the same temperature between 70 degrees F and 75 degrees F
inclusive, and assumed to be constant throughout the year.
3. Thermostats that require manual changeover between heating and
cooling modes.
1412.3 Humidity Controls: If a system is equipped with a means for adding
moisture, a humidistat shall be provided.
1412.4 Setback and Shut - Off: HVAC systems shall be equipped with automatic
controls capable of accomplishing a reduction of energy use through control setback
or equipment shutdown during periods of non -use or alternate use of the spaces
served by the system. The automatic controls shall have a minimum seven -day
clock and be capable of being set for seven different day types per week It must
retain programming and time for a power loss of 10 hours and include an accessible
manual override of up to 2 hours.
Exceptions:
1. Systems serving areas which require continuous operation at the
same temperature setpoint.
2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may
be controlled by readily accessible manual off -hour controls.
3. Systems controlled by an occupant sensor that is capable of shutting
the system off when no occupant is sensed for a period of up to 30
minutes.
4. Systems controlled solely by a manually operated timer capable of
operating the system for no more than two hours.
1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving
conditioned spaces shall be equipped with dampers which dose automatically when
the system is off or upon power failure. Stair shaft and elevator shaft smoke relief
openings shall be equipped with normally open (fails to open upon loss of power)
dampers. These dampers shall remain dosed until activated by the fire alarm
system or other approved smoke detection system.
Exceptions:
1. Systems serving areas which require continuous operation.
2. Combustion air intakes.
3. Gravity (nonmotorized) dampers are acceptable in buildings less
than 3 stories in height.
4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief
outlets in the first story and levels below the first story of buildings
1412.8 Ventilation Controls for High - Occupancy Areas: Demand control
ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design
occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are
served by systems with one or more of the following:
a. An air -side economizer,
b. Automatic modulating control of the outdoor air damper, or
c. A design outdoor airflow greater than 3000 cfm.
Exceptions:
1.Systems with energy recovery complying with Section 1436.
2. Multiple -zone systems without direct - digital control of individual zones
communicating with a central control panel.
3. Systems with a design outdoor airflow less than 1200 cfm.
4. Spaces where the supply airflow rate minus any makeup or outgoing
transfer air requirement is less than 1200 cfm.
1413 Air Economizers
1413.1 Operation: Air economizers shall be of automatically modulating outside and
return air dampers to provide 100 percent of the design supply air as outside air to
reduce or eliminate the need for mechanical cooling. Water economizers shall be
capable of providing the total concurrent cooling load served by the conneted
terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F
dry- bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and
internal load shall be the same as those used for peak load calculations, except for
the outside temperatures.
Exception: Water economizers using air- cooled heat rejection equipment
may use a 35 ° F dry-bulb outside air temperature for this calculation. This
exception is limited to a maximum of 20 tons per building.
1413.2 Documentation: Water economizer plans submitted for approval shall
include the following information:
1. Maximum outside air conditions for which economizer is sized to provide
full cooling.
2. Design cooling load to be provided by economizer at this outside air
condition.
3. Heat rejection and terminal equipment performance data including model
number, flow rate, capacity, entering and leaving temperature in full
economizer cooling mode.
1413.3 Integrated Operation: Air economizers shall be capable of providing partial
cooling even when additional mechanical cooling is required to meet the remainder
of the cooling load.
Exceptions:
1. Individual, direct expansion units that have a rated capacity less than
65,000 Btu/h and use nonintegrated economizer controls that
preclude simultaneous operation of the economizer and mechanical
cooling.
2. Water - cooled water chillers with waterside economizer.
1413.4 Humidification: If an air economizer is required on a cooling system for
which humidification equipment is to be provided to maintain minimum indoor
humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative
media or fog atomization type).
Exceptions:
1. Health care facilities where WAC 246 - 320 -525 allows only steam
injection humidifiers in ductwork downstream of final filters. 1412.6
Combustion Heating Equipment Controls: Combustion heating
equipment with a capacity over 225,000 Btu/h shall have modulating
or staged combustion control.
2. Systems with water economizer
3. 100% outside air systems with no provisions for air recirculation to the
central supply fan.
4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a
building's air economizer capacity as measured in cfm. This refers to
the system cfm serving rooms with stand alone or duct mounted
humidifiers.
1414 Ducting Systems
1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch
water column static pressure shall be sealed in accordance with Standard RS-18.
Extent of sealing required is as follows:
1. Static pressure: 1/2 inch to 2 inches; seal transverse joints.
2. Static pressure: 2 inches to 3 inches; seal all transverse joints and
longitudinal seams.
3. Static pressure: above 3 inches; seal all transverse joints, longitudinal
seams and duct wall penetrations.
Duct tape and other pressure sensitive tape shall not be used as the primary
sealant where ducts are designed to operate at static pressures of 1 inch W.C. or
greater.
1414.2 Insulation: Ducts and plenums that are constructed and function as part of
the building envelope, by separating interior space from exterior space, shall meet all
applicable requirements of Chapter 13. These requirements include insulation
installation, moisture control, air leakage, and building envelope insulation levels.
Unheated equipment rooms with combustion air louvers must be isolated from the
conditioned space by insulating interior surfaces to a minimum of R -11 and any
exterior envelope surfaces per Chapter 13. Outside air ducts serving individual
supply air units with less than 2,800 cfm of total supply air capacity shall be insulated
to a minimum of R -7 and are not considered building envelope. Other outside air
duct runs are considered building envelope until they,
EF
CAE
< 50 gal storage
0.58
0.71
50 to 70 gal storage
0.57
0.71
> 70 gal storage
0.55
0.70
2006 Washin•ton State Nonresidential Ener. Code Corn liance Form
Mechanical Permit Plans
Checklist
MECH CHK
2006 Washington State Nonresidential Energy Code Compliance Forms
Revised July 2007
Mechanical - General Requirements
1411.1 General: Equipment shall have a minimum performance at the specified
rating conditions not less than the values shown in Table 14-1A through 14-1G. If a
nationally recognized certification program exists for a product covered in Tables
14-1A through 14-1G, and it includes provisions for verification and challenge of
equipment efficiency ratings, then the product shall be listed in the certification
program.
Gas -fired and oil -fired forced air furnaces with input ratings? 225,000 Btu/h (65
kW) and all unit heaters shall also have an intermittent ignition or interrupted device
(IID), and have either mechanical draft (including power venting) or a flue damper. A
vent damper is an acceptable alternative to a flue damper for furnaces where
combustion air is drawn from the conditioned space. All furnaces with input ratings >
225,000 Btu/h (65 kW), including electric furnaces, that are not located within the
conditioned space shall have jacket losses not exceeding 0.75% of the input rating.
1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions
and procedures when available. Where no applicable procedures exist, data shall
be furnished by the equipment manufacturer.
1411.3 Combination Space and Service Water Heating: For combination space
and service water heaters with a principal function of providing space heat, the
Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard
124 -1991. Storage water heaters used in combination space heat and water heat
applications shall have either an Energy FActor (EF) or a CAE of not less than the
following:
1411.4 Packaged Electric Heating and Coo ing Equipment: Packaged electric
equipment providing both heating and cooling with a total cooling capacity greater
than 20, Btu/h shall be a heat pump.
Exception: Unstaffed equipment shaelters or cabinets used solely for
personal wireless service facilities.
1412 Controls
1412.1 Temperature Controls: Each system shall be provided with at least one
temperature control device. Each zone shall be controlled by individual thermostatic
controls responding to temperature within the zone. At a minimum, each floor of a
building shall be considered as a separate zone.
1412.2 Deadband Controls: When used to control both comfort heating and
cooling, zone thermostatic controls shall be capable of a deadband of at least 5
degrees F within which the supply of heating and cooling energy to the zone is shut
off or reduced to a minimum.
Exceptions:
1. Special occupancy, special usage, or code requirements where
deadband controls are not appropriate.
2. Buildings complying with Section 1141.4, if in the proposed building
energy analysis, heating and cooling thermostat setpoints are set to
the same temperature between 70 degrees F and 75 degrees F
inclusive, and assumed to be constant throughout the year.
3. Thermostats that require manual changeover between heating and
cooling modes.
1412.3 Humidity Controls: If a system is equipped with a means for adding
moisture, a humidistat shall be provided.
1412.4 Setback and Shut - Off: HVAC systems shall be equipped with automatic
controls capable of accomplishing a reduction of energy use through control setback
or equipment shutdown during periods of non -use or alternate use of the spaces
served by the system. The automatic controls shall have a minimum seven -day
clock and be capable of being set for seven different day types per week It must
retain programming and time for a power loss of 10 hours and include an accessible
manual override of up to 2 hours.
Exceptions:
1. Systems serving areas which require continuous operation at the
same temperature setpoint.
2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may
be controlled by readily accessible manual off -hour controls.
3. Systems controlled by an occupant sensor that is capable of shutting
the system off when no occupant is sensed for a period of up to 30
minutes.
4. Systems controlled solely by a manually operated timer capable of
operating the system for no more than two hours.
1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving
conditioned spaces shall be equipped with dampers which dose automatically when
the system is off or upon power failure. Stair shaft and elevator shaft smoke relief
openings shall be equipped with normally open (fails to open upon loss of power)
dampers. These dampers shall remain dosed until activated by the fire alarm
system or other approved smoke detection system.
Exceptions:
1. Systems serving areas which require continuous operation.
2. Combustion air intakes.
3. Gravity (nonmotorized) dampers are acceptable in buildings less
than 3 stories in height.
4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief
outlets in the first story and levels below the first story of buildings
1412.8 Ventilation Controls for High - Occupancy Areas: Demand control
ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design
occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are
served by systems with one or more of the following:
a. An air -side economizer,
b. Automatic modulating control of the outdoor air damper, or
c. A design outdoor airflow greater than 3000 cfm.
Exceptions:
1.Systems with energy recovery complying with Section 1436.
2. Multiple -zone systems without direct - digital control of individual zones
communicating with a central control panel.
3. Systems with a design outdoor airflow less than 1200 cfm.
4. Spaces where the supply airflow rate minus any makeup or outgoing
transfer air requirement is less than 1200 cfm.
1413 Air Economizers
1413.1 Operation: Air economizers shall be of automatically modulating outside and
return air dampers to provide 100 percent of the design supply air as outside air to
reduce or eliminate the need for mechanical cooling. Water economizers shall be
capable of providing the total concurrent cooling load served by the conneted
terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F
dry- bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and
internal load shall be the same as those used for peak load calculations, except for
the outside temperatures.
Exception: Water economizers using air- cooled heat rejection equipment
may use a 35 ° F dry-bulb outside air temperature for this calculation. This
exception is limited to a maximum of 20 tons per building.
1413.2 Documentation: Water economizer plans submitted for approval shall
include the following information:
1. Maximum outside air conditions for which economizer is sized to provide
full cooling.
2. Design cooling load to be provided by economizer at this outside air
condition.
3. Heat rejection and terminal equipment performance data including model
number, flow rate, capacity, entering and leaving temperature in full
economizer cooling mode.
1413.3 Integrated Operation: Air economizers shall be capable of providing partial
cooling even when additional mechanical cooling is required to meet the remainder
of the cooling load.
Exceptions:
1. Individual, direct expansion units that have a rated capacity less than
65,000 Btu/h and use nonintegrated economizer controls that
preclude simultaneous operation of the economizer and mechanical
cooling.
2. Water - cooled water chillers with waterside economizer.
1413.4 Humidification: If an air economizer is required on a cooling system for
which humidification equipment is to be provided to maintain minimum indoor
humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative
media or fog atomization type).
Exceptions:
1. Health care facilities where WAC 246 - 320 -525 allows only steam
injection humidifiers in ductwork downstream of final filters. 1412.6
Combustion Heating Equipment Controls: Combustion heating
equipment with a capacity over 225,000 Btu/h shall have modulating
or staged combustion control.
2. Systems with water economizer
3. 100% outside air systems with no provisions for air recirculation to the
central supply fan.
4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a
building's air economizer capacity as measured in cfm. This refers to
the system cfm serving rooms with stand alone or duct mounted
humidifiers.
1414 Ducting Systems
1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch
water column static pressure shall be sealed in accordance with Standard RS-18.
Extent of sealing required is as follows:
1. Static pressure: 1/2 inch to 2 inches; seal transverse joints.
2. Static pressure: 2 inches to 3 inches; seal all transverse joints and
longitudinal seams.
3. Static pressure: above 3 inches; seal all transverse joints, longitudinal
seams and duct wall penetrations.
Duct tape and other pressure sensitive tape shall not be used as the primary
sealant where ducts are designed to operate at static pressures of 1 inch W.C. or
greater.
1414.2 Insulation: Ducts and plenums that are constructed and function as part of
the building envelope, by separating interior space from exterior space, shall meet all
applicable requirements of Chapter 13. These requirements include insulation
installation, moisture control, air leakage, and building envelope insulation levels.
Unheated equipment rooms with combustion air louvers must be isolated from the
conditioned space by insulating interior surfaces to a minimum of R -11 and any
exterior envelope surfaces per Chapter 13. Outside air ducts serving individual
supply air units with less than 2,800 cfm of total supply air capacity shall be insulated
to a minimum of R -7 and are not considered building envelope. Other outside air
duct runs are considered building envelope until they,
III , WWI ,, ,. .2Q.06 Washington S tatalloziresidential- Energy .Gode Eornplianee•Form- -- .._..., _.. -.
outlets in the first story and levels below the first story of buildings duct runs are considered building envelope until they,
three or more stones in height. 1. connect to the heating or cooling equipment, or
1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply
air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum
start controls shall be designed to automatically adjust the start time of an HVAC
system each day to bring the space to desired occupied temperature levels
immediately before scheduled occupancy. The control algorithm shall, as a
minimum, be a function of the difference between space temperature and occupied
setpoint and the amount of time prior to scheduled occupancy.
1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include
microprocessor controls that minimize supplemental heat usage during start-up, set-
up, and defrost conditions. These controls shall anticipate need for heat and use
compression heating as the first stage of heat. Controls shall indicate when
supplemental heating is being used through visual means (e.g., LED indicators).
1412.6 Combustion Heating Equipment Controls: Combustion heating equipment
with a capacity over 225,000 Btu/h shall have modulating or staged combustion
control. 000
EXCEPTIONS: 1. Boilers. 2. Radiant heaters.
1412.7 Balancing: Each air supply outlet or air or water terminal device shall have
a means for balancing, including but not limited to, dampers, temperature and
pressure test connections and balancing valves.
2. are isolated from the exterior with an automatic shut-off damper complying
with Section 1412.4.1.
Once outside air ducts meet the above listed requirements, any runs within
conditioned space shall comply with Table 14-5 requirements.
Other ducts and plenums shall be thermally insulated per Table 14 -5.
Exceptions:
1. Within the HVAC equipment.
2. Exhaust air ducts not subject to condensation.
3. Exposed ductwork within a zone that serves that zone.
1415 Piping Systems
1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14.6.
Exception: Piping installed within unitary HVAC equipment.
Water pipes outside the conditioned space shall be insulated in accordance with
Washington State Plumbing Code (WAC 51 -26)
1416 Completion Requirements (Refer to NREC Section 1416 and the Building
Commissioning Guidelines, published by the Building Commissioning Association,
for complete text and guidelines for building completion and commissioning
requirements.)
05 -04 -2009
BRIAN VAN STIPDONK
1200 6 AV, STE 500
SEATTLE WA 98101
RE: Permit No. M08 -190
320 STRANDER BL TUKW
Dear Permit Holder:
Thank you for your cooperation in this matter.
Sincerely,
Bill Rambo
Permit Technician
xc: Permit File No. M08 -190
Guy of Tukwila
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division.
Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the
provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not
commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or
abandoned at any time after the work is commenced for a period of 180 days.
Based on the above, you are hereby advised to:
Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection.
This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if
the project should be considered abandoned.
If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for
additional periods not exceeding 90 days each. Extension requests must be in writing and provide satisfactory reasons why
circumstances beyond the applicants control have prevented action from being taken.
In the event you do not call for the above inspection and receive an extension prior to 06/07/2009 , your permit will become null and
void and any further work on the project will require a new permit and associated fees.
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
12 -03 -2008
BRIAN VAN STIPDONK
1200 6 AV, STE 500
SEATTLE WA 98101
Dear Permit Applicant:
RE: Permit Application No. M08 -190
320 STRANDER BL TUKW
Department of Community Development
Jim Haggerton, Mayor
Jack Pace, Director
In reviewing our current permit application files, it appears that your permit application applied for on 07/18/2008 , has not been
issued by the City of Tukwila Permit Center. Per the International Building Code and/or the International Mechanical Code, every
permit application not issued within 180 days from the date of application shall expire by limitation and become null and void. Your
permit application expires on 01/14/2009 .
If you choose to pursue your project, a written request for extension of your application addressed to the Building Official,
demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 01/14/2009. If it is
determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date.
In the event we do not receive your written request for extension, your permit application will become null and void and your project
will require a new permit application, plans and specifications, and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
r Marsh • 1
Technician
xc:
Permit File No. M08 -190
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
J .
July 22, 2008
Brian VanStipdunk
1200 Sixth Avenue, Suite 500
Seattle, WA 98101
RE: Letter of Incomplete Application # 1
Development Permit Application M08 -190
Bank of America — Strander BI
Dear Mr. Van Stipdunk,
This letter is to inform you that your permit application received at the City of Tukwila Permit Center on July 18, 2008 is
determined to be incomplete. Before your application can continue the plan review process the following items from the
following department needs to be addressed:
Building Department: Allen Johannessen at 206 433 -7163 if you have any questions concerning the
attached comments.
Please address the comment above in an itemized format with applicable revised plans, specifications, and /or other
documentation. The City requires that two (2) sets of revised plans, specifications and/or other documentation be
resubmitted with the appropriate revision block.
In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have
enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by
a messenger service.
If you have any questions, please contact me at the Permit Center at (206) 431 -3670.
Brenda Holt
Permit Coordinator
Enclosures
File: M08 -190
Department of Community Development Jack Pace, Director
P: \Permit Center\Incomplete Letters\2008\M08 -190 Incomplete Ltr # 1.DOC
jem
•
Jim Haggerton, Mayor
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
•
Determination of Completeness Memo
Date: July 22, 2008
Project Name: Bank of America
Permit #: M08 -190
Plan Review: Allen Johannessen, Plans Examiner
Tukwila Building Division
Allen Johannessen, Plan Examiner
The Building Division has deemed the subject permit application incomplete. To assist the applicant in
expediting the Department plan review process, please forward the following comments.
(GENERAL NOTE)
PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size).
(If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped,
not copied.)
1. New mechanical equipment to be installed on the roof exceeding 400 pounds shall require an engineer's
analysis for the roof structure with calculations to show the roof structural members are sufficient for the
combined loads imposed by all the mechanical equipment. Provide specific details with the engineer's
calculations. In addition, details shall show how units secure to the curbs to resist wind and seismic loads.
All engineer's documents shall be original wet stamped and signed by the engineer. (IMC 106.3.1, 301.12,
Section 302, IBC 1606.2)
Should there be questions concerning the above requirements, contact the Building Division at 206 - 431 -3670.
No further comments at this time.
ACTIVITY NUMBER: M08-190 DATE: 08-05-08
PROJECT NAME: BANK OF AMERICA
SITE ADDRESS: '1e0 STRANDER BL
Original Plan Submittal X Response to Incomplete Letter # 1
Response to Correction Letter #
Revision # After Permit Issued
DEP RTM NT • , 0
ill ding Division
Public Works El
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
PERMIT COORD COPY 41
PLAN REVIEW/ROUTING SLIP
. • . , ,
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials:
Please Route
Documents/routing slip.doc
2-28-02
TUES/THURS RO TING:
APPROVALS OR CORRECTIONS:
Fire Prevention
Structural
Incomplete
Structural Review Required
LI
n
Planning Division
LI Permit Coordinator
DUE DATE: 08-07-08
Not Applicable
LI No further Review Required
LI
REVIEWER'S INITIALS: DATE:
DUE DATE: 09-04-08
LI
LI
Approved 0 Approved with Conditions 0 Not Approved (attach comments) n
Notation:
REVIEWER'S INITIALS: DATE:
Peimit Center Use Only '•
• .: •••• -
.• .
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials:
ACTIVITY NUMBER: M08 -190 DATE: 07 -18 -08
PROJECT NAME: BANK OF AMERICA
SITE ADDRESS:
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # after Permit Issued
DEPARTMENTS:
to
Public Works
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
Please Route
Permit Center Use Only
INCOMPLETE LETTER MAILED: � LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg V Fire ❑ Ping ❑ PW ❑ Staff Initial
TUES/THURS ROUTING:
n
REVIEWER'S INITIALS:
APPROVALS OR CORRECTIONS:
PLAN REVIEW /ROUTING SLIP
r o5
Structural
Incomplete
Structural Review Required
Approved 1 Approved with Conditions
Notation:
REVIEWER'S INITIALS:
Documents/routing slip.doc
2 -28 -02
"'PERMIT COORD COPY Eli
�(pr7 c. 1. S.06
Fire Prevention IN Planning Division
DATE:
DATE:
Permit Coordinator
No further Review Required
Not Approved (attach comments)
n
DUE DATE: 07-22-08
Not Applicable ❑
DUE DATE: 08-19-08
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through
the mail, fax, etc.
Date: 'I J a Plan Check/Permit Number: M08-190
• Response to Incomplete Letter # 1 _
❑ Response to Correction Letter #
❑ Revision # after Permit is Issued
❑ Revision requested by a City Building Inspector or Plans Examiner
Project Name: BANK OF AMERICA
Project Address: 3XX Strander B1
Contact Person: Brian VanStipdonk
Summary of R vision:
la AV
RECEIVED
OITVS TUKWILA
AUG 0.5' HOS
Sheet Number(s):
"Cloud" or highlight all areas of revision including date o revisio
Received at the City of Tukwila Permit Center by:
Entered in Permits Plus on e-s- -U 8
\applications\forms- applications on line\revision submittal
Created: 8 -13 -2004
Revised:
Phone Number:
PERMIT CENTER
Bond
Bond
Company
Name
Bond
Account
Number
Effective
Date
Expiration
Date
Cancel
Date
Impaired
Date
Bond
Amount
Received
Date
2
AMERICAN
CONTRACTORS
INDEM CO
100018683
02/17/2007
Until
Cancelled
$12,000.00
02/26/2007
1
ACCREDITED
SURETY It CAS
CO
10034059
06/27/2005
Until
Cancelled
02/17/2007
$12,000.0006/28
/2005
Name
Role
Effective Date
Expiration Date
OKITSU, RODNEY STERLING
AGENT
06/28/2005
Amount
OKITSU, RODNEY STERLING
PRESIDENT
06/28/2005
CPP1002918
Insurance
Company
Name
Policy
Number
Effective
Date
Expiration
Date
Cancel
Date
Impaired
Date
Amount
Received
Date
5
WESTERN
NATIONAL
ASSUR CO
CPP1002918
10/13/200810/13
/2009
$1,000,000.0010
/13/2008
4
OHIO CAS
INS CO
BL053526359
08/13/200708/13
/2009
$1,000,000.0008
/11/2008
Untitled Page
General /Specialty Contractor
A business registered as a construction contractor with L&I to perform construction work
within the scope of its specialty. A General or Specialty construction Contractor must
maintain a surety bond or assignment of account and carry general liability insurance.
Business and Licensing Information
Name
Phone
Address
Suite /Apt.
City
State
Zip
County
Business Type
Parent
Company
OKITSU CONSTRUCTION
INC
2067149969
1428 WHITWORTH AVE S
RENTON
WA
98055
KING
CORPORATION
UBI No.
Status
License No.
License Type
Effective Date
Expiration Date
Suspend Date
Previous License
Next License
Associated
License
Specialty 1
Specialty 2
602515973
ACTIVE
OKITSCI959L8
CONSTRUCTION
CONTRACTOR
6/28/2005
6/28/2009
OKITSC*030R3
GENERAL
UNUSED
Business Owner Information
Bond Information
Insurance Information
S
•
Page 1 of 2
https: // fortress .wa.gov /lni/bbip/Detail. aspx ?License= OKITSCI959L8
12/09/2008
FAN SCHEDULE
TAG
DESIGN
BASIS
LOCATION
AREA /SYSTEM
SERVED
TYPE
DRIVE
FAN
ELECTRICAL CHARACTERISTICS
NOM UNIT
•IZE (LxWxH, IN
OPERATING
WT (LBS)
NOTES
AIRFLOW
(CFM)
ESP
(IN WC)
RPM
RPM
VOLT/
PH
BHP
MOTOR
(HP)
STARTER
FUSED DISC
UNIT VOL
CONTROL
POWER
SOURCE
PTS OF
CONN
DIV 23
DIV 26
DIV 23
DIV 26
AEF -R.1
GREENHECK CSP
ATM ROOM
ATM ROOM
CEIUNG
DIRECT
380
0.5
1070
24x24
115/1
-
217 W
1 THUR 5
-
X
-
CONSTANT
NORMAL
ONE (1)
14x18x14
40
1
TITUS 25RL
SIDEWALL RETURN GRILLE
SEE DRAWING
1/2* SPACING, 30 DEGREE DEFLECTION
Y T
WHITE
1 THRU 6
S ■ EEL
G
TTTUS 355ZRS
EXHAUST GRILLE
SEE DRAWING
1/2" SPACING, 0 DEGREE DEFLECTION
ALUMINUM
WHITE
WHITE
1 THRU 6
1 THRU 6
H
TITUS MLR -39
LINEAR SLOT RETURN
4' LONG
2 -SLOT, 1" WIDTH
STEEL
Heat pump control
REF -R.2
CANFAB
ROOF
RTU -R.2 - POWER EXHASUTER
DOWNBLAST
BELT
4000
0.2
902
1750
208/3
Balancing
Indicate balancing features on plans
VFD
-
--
NM VFD BY DIV 15
NORMAL
ONE (1)
48x36x24
400
1,4
REF -R.3
CANFAB
ROOF
RTU -R.3 - POWER EXHASUTER
DOWNBLAST
BELT
790
0.4
865
1750
208/3
1413
VFD
,,
1413.1
VFD BY DIV 15
NORMAL
ONE (1)
42x30x22
300
1,4
Mr Econo Operation
Indicate 100% capacity at 45 degF db & 40 deg F w b
JC /RESTROOM /BREAKROOM
DOWNBLAST
BELT
730
0.5
1193
1725
1110131111
0.11
Integrated operation
-
-
X
IIII CONSTANT
NORMAL
ONE (1)
24 DIAx24
60
1 THRU 3
TEF -R.1
GREENHECK GB
ROOF
Indicate sealing necessary
M00.02
Y „„
1414.2
Duct insulation
Indicate R -value of insulation on duct
111111111.1111.11111111111111
Y „
11111111111111M
Piping insulation
Indicate R -value of insulation on piping
m00.02
r ` ^
1416
Completion Requirements
NOTES:
IN COMPLIANCE Wff-1 MECHANICAL AND ELECTRICAL CODE REQUIRED WORKING CLEARANCES. 4. PROVIDE WITH ROOFTOP UNIT, SEE RTU SCHEDULE.
ROOF CURB.
MOTORIZED DAMPER.
1416.2.1
Commissioning
5/20/2008 8:30
1. INSTALL
2. PROVIDE
3. PROVIDE
DIFFUSER SCHEDULE
TAG
DESIGN BASIS
DESCRIPTION
MODULE SIZE
FACE
MATERIAL
COLOR
- -
NOTES
A
TITUS OMNI
CEILING DIFFUSER
24x24
SQUARE PLAQUE
STEEL
WHITE
1 THUR 5
B
TITUS ML -38 W/ MPI -38
LINEAR SLOT DIFFUSER
4' LONG WI INSULATED PLENUM
2 -SLOT, 3/4" WIDTH
PTS OF
CONN
WHITE
1 THUR 5
S 1 EEL
C
TITUS 272RS
SIDEWALL SUPPLY GRILLE
SEE DRAWING
3/4" SPACING, DOUBLE DEFLECTION
STEEL
WH ITE
1 THUR 5
D
ACCUTHERM THERMA-FUSER
CEIUNG DIFFUSER -VAV
24x24
SQUARE PLAQUE
STEEL
WHITE
1 THUR 5
E
TITUS 50F
RETURN /EXHAUST GRILLE
SEE DRAWING
1/2 x 1/2 x 1/2 EGGCRATE
ALUMINUM CORE, ALUMINUM BORDER
WHITE
1 THRU 6
F
TITUS 25RL
SIDEWALL RETURN GRILLE
SEE DRAWING
1/2* SPACING, 30 DEGREE DEFLECTION
Y T
WHITE
1 THRU 6
S ■ EEL
G
TTTUS 355ZRS
EXHAUST GRILLE
SEE DRAWING
1/2" SPACING, 0 DEGREE DEFLECTION
ALUMINUM
WHITE
WHITE
1 THRU 6
1 THRU 6
H
TITUS MLR -39
LINEAR SLOT RETURN
4' LONG
2 -SLOT, 1" WIDTH
STEEL
Heat pump control
Indicate microprocessor on thermostat schedule
NOTES:
CONDENSATE PUMP, COORDINATE 1/8 HP 120V/1PH CONNECTION WITH DIV 26. 4. ROUTE REFRIGERANT LINES IN WALL. 7. PROVIDE 100% ECONOMIZER WITH MIXING BOX AND DELUXE MA CONTROLLER
PUMPED CONDENSATE TO JANITOR'S CLOSET MOP SINK. 5. INSTALL UNIT PER MANUFACTURER'S SPECIFICATIONS.
EQUIVALENT LENGTH OF REFRIGERANT LINES TO BE 100 FEET. 6. ROVIDE HFC REFRIGERANTS; R -410A
4/17/2008 8:17
1. PROVIDE
2. PROUTE
3. MAXIMUM
Combustion htg.
Indicate modulating or staged control
NOTES:
NC TO BE 35. 5. REVIEW ARCHITECTURAL REFLECTED CEILING PLANS FOR BORDER TYPES.
TOTAL PRESSURE TO BE 0.1 W.G. 6. SIZE DUCT BRANCH CONNECTION PER GRILLE SIZE . INDICATED ON PLAN.
CLEAR ANODIZED FINISH.
COLOR WM-I ARCHIECT.
4/17/2008 8:17
1. MAX
2. MAX
3. PROVIDE
4. COORDINATE
SPLIT SYSTEM HEAT PUMP UNIT SCHEDULE
TAG
FCU -1.1
DESIGN
BASIS
MITSUBISHI MSZ -A15
LOCATION
ATM
AREA
SERVED
ATM
SUPPLY
CFM
640
COOLING
COOLING
SEER
-
ELECTRICAL CHARACTERISTICS
NOM UNIT
SIZE (LxWxH, IN)
OPERATING
WT (LBS)
NOTES
TOTAL
MBH
36
TOTAL
MBH
4O
VOLT/
PH
208/1
LOAD
MCA
MEMINIESI
MOCP
STARTER
FUSED DISC
UNIT VOL
CONTROL
POWER
SOURCE
PTS OF
CONN
DIV 23
X
DIV 26
-
DIV 23
-a-
DIV 26
X
CONSTANT
NORMAL
TWO (2)
31x60x14
130
1 THRU 5, 7
CU -R.1
MITSUBISHI PUMY -P36
ROOF
ATM
-
36
40
16
208/1
26
40
X
-
M00.01
x
CONSTANT
NORMAL
ONE (1)
38x14x54
320
3 THRU 6
Y T
412.4
Automatic setback
Indicate thermostat w ith night setback and 7 diff. day types
Mo o . 0
n a „.
1412.4.1
Dampers
Indicate damper location and auto. controls & max. leakage
m00 . 0
Y „
1412.4.2
Optimum Start
Indicate optimum start controls
n a. „
1412.5
Heat pump control
Indicate microprocessor on thermostat schedule
NOTES:
CONDENSATE PUMP, COORDINATE 1/8 HP 120V/1PH CONNECTION WITH DIV 26. 4. ROUTE REFRIGERANT LINES IN WALL. 7. PROVIDE 100% ECONOMIZER WITH MIXING BOX AND DELUXE MA CONTROLLER
PUMPED CONDENSATE TO JANITOR'S CLOSET MOP SINK. 5. INSTALL UNIT PER MANUFACTURER'S SPECIFICATIONS.
EQUIVALENT LENGTH OF REFRIGERANT LINES TO BE 100 FEET. 6. ROVIDE HFC REFRIGERANTS; R -410A
4/17/2008 8:17
1. PROVIDE
2. PROUTE
3. MAXIMUM
LOUVER/RELIEF VENT SCHEDULE
TAG
DESIGN
BASIS
LOCATION
AREA SERVED
DUCT SIZE
(IN)
NOM UNIT
SIZE (DIAxH, IN)
AIRFLOW
(CFM)
OPERATING
WT (LBS)
NOTES
GRV-R.1
GREENHECK GRSI -18
ROOF
ATM ROOM
18
36DIAx12
3900
70
1 THRU 4
GRV-°-R.2
GREENHECK GRSR -18
ROOF
CHILLER ROOM
18
36DIAx12
2000
30
1 THRU 4
n a
1411.1
Combustion htg.
Indicate intermittent ignition, flue /draft damper & jacket loss
1412
HVAC controls
NOTES:
FAIL OPEN 24V MOTORIZED BACKDRAFT DAMPER. 3. PROVIDE GALVANIZED BIRDSCREEN.
12" HIGH ROOF CURB. 4. PROVIDE 0.5" THICK HOOD INSULATION.
4/23/2008 12:19
1. PROVIDE
2. PROVIDE
NONRESIDENTIAL ENERGY CODE COMPLIANCE SCHEDULE
COMPONENT
INFORMATION
THERMOSTAT DEADBAND CONTROL
5' F.
THERMOSTAT AUTOMATIC
SETBACK
NIGHT SETBACK AND 7 DIFFERENT DAY TYPES
COMPLY WITH STANDARD RS 18.
SEALING DUCTWORK
STATIC PRESSURE: 1/2" TO 3" ; SEAL TRANSVERSE JOINTS AND
LONGITUDINAL SEAMS
STATIC PRESSURE: ABOVE 3" ; SEAL TRANSVERSE JOINTS,
LONGITUDINAL SEAMS, AND DUCT WALL PENETRATIONS
DUCT INSULATION
SUPPLY AND RETURN
NOT WITHIN CONDITIONED SPACE: R -7
OUTSIDE AIR INTAKE
WITHIN CONDITIONED SPACE: R-7
SUPPLY AND RETURN, OUTSIDE
AIR INTAKE
NOT WITHIN CONDITIONED SPACE; IN CONCRETE, IN GROUND: R -5.3
SUPPLY WITH SUPPLY AIR TEMP.
< 55' F. OR >105' F.
WITHIN CONDONED SPACE: R -3.3
PIPE INSULATION
PIPING SHALL BE THERMALLY INSULATED IN ACCORDANCE WITH
WASHINGTON STATE ENERGY CODE, 2006 EDITION, TABLE 14 -6
yes „
3 /15/2006 1
Project Info
Project Address BANK OF AMERICA
Date 3.5.08
320 STRANDER BLVD.
For Building Dept. Use
TUKWILA, WA 98188
Applicant Name: GLUMAC
Applicant Address: 1325 4TH AVE STE 1515, SEATTLE, WA 98101
Applicant Phone: 206,262.1010
Compliance Option
0 Simple System • Complex System Q Systems Analysis a
(See Decision Flowchart (over) for qualifications. Use separate MECH- SUMfor simple & complex systems.)
Mechanical Permit Plans Checklist K
MECH -CHK
Project Address
BANK OF AMERICA - TUKWILA
Date
3.5.08
The follow ing information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the
Washinnton State Nonresidential Fnerav Code.
Applicability
(yes, no, n.a.)
Code
Section
Component
Information Required
Location
on Flans
Building Department
Notes
HVAC REQUIREMENTS (Sections 14014424)
1411
Equipment performance
yes „
1411.4
Pkg. elec. htg.& clg,
List heat pumps on schedule
M00-02
yes „
1411.1
Mnimum efficiency
Equipment schedule with type. capacity, efficiency
Mo 0. 02
n a
1411.1
Combustion htg.
Indicate intermittent ignition, flue /draft damper & jacket loss
1412
HVAC controls
Y '
1412.1
Temperature zones
Indicate locations on plans
MO2.01
y ,,
1412.2
leadband control
Indicate 5 degree deadband minimum
M00.01
n.a. .r
1412.3
Humidity control
Indicate humidistat
Y T
412.4
Automatic setback
Indicate thermostat w ith night setback and 7 diff. day types
Mo o . 0
n a „.
1412.4.1
Dampers
Indicate damper location and auto. controls & max. leakage
m00 . 0
Y „
1412.4.2
Optimum Start
Indicate optimum start controls
n a. „
1412.5
Heat pump control
Indicate microprocessor on thermostat schedule
n.a. w
1412.6
Combustion htg.
Indicate modulating or staged control
Y- es „
1412.7
Balancing
Indicate balancing features on plans
MO2.01
n.a. ,„
1412.8
Ventilation Control
Indicate demand control ventilation for high- occupancy areas
n.e. -s
1422
Thermostat interlock
Indicate thermostat interlock on plans
Y
1423
Economizers
Equipment schedule
M00.02
1413
Air economizers
,,
1413.1
Air Econo Operation
Indicate 100% capability on schedule
Moo . 02
n a „
1413.1
Mr Econo Operation
Indicate 100% capacity at 45 degF db & 40 deg F w b
n.a. „,
1413.2
Water Econo Doc
Indicate clg load & w ater econoe & clg tow er performance
yes
1413.3
Integrated operation
Indicate capability for partial cooling
M00.02
n a r
1413.4
Humidification Indicate direct evap or fog atomization w I air economizer
1414
Ducting systems
Yes
1414.1
Duct sealing
Indicate sealing necessary
M00.02
Y „„
1414.2
Duct insulation
Indicate R -value of insulation on duct
MO 0. 02
Y „
1415.1
Piping insulation
Indicate R -value of insulation on piping
m00.02
r ` ^
1416
Completion Requirements
Y ,,,
1416.2.1
Commissioning
Provide commissioning plan
m00.01
yes „,
1416.2.2 -3
Sys.Bat & Func.Test
Indicate air and w ater system balancing & functional testing
MO 0.01
yes .' ,
1416.2.4
Commissioning
Indicate O &M manuals, record draw ings, staff training
M00.01
yes -
1416.2.5
Comm. Report
Indicate requirements for prelim. & final commissioning report
MOO. 01
Separate air sys.
Indicate separate systems on plans
MO2.01
Y 1434
yes
- "
Mechanical
Summary Form
Completed and attached. Equipment schedule w ith types,
input /output, efficiency, cfm, hp, economizer
Moo . o 2
AREA SERVED
WEST
LOBBY
SOUTH
O
NER
NOM
CAPACITY (TONS)
4
10
3
4
3
SUPPLY
AIR FLOW
(CFM)
1620
4000
1320
1760
1200
ESP
(IN WG)
0.75
1 .0
0.8
1.0
0.5
OSA
INTAKE
(CFM)
360
1260
665
610
COOLING
TOTAL SENS
(MBH (MBH)
48.35
35.2
107.1
99.8
44.8
41.7
44.7
42.3
EAT
(DB /WB)
73/63
76/62
77/65
74/61
LAT
(DB /WB)
55/54
58/57
56/55
HEATING
INPUT
(MBH)
80
200
80
120
OUTPUT
(MBH)
64
162
64
96
EAT
(DB /WBI
59
46
59
108
AFUE
) ( %)
80
80
80
80
EER/
SEER
VOLT/
PH
MEIN
ELECTRICAL CHARACTERISTICS
208/3
208/3
LOAD MOCP
(MCA)
55.9
60
20.9
30
28.3
40
20.9
30
STARTER
DIV 23
MEM
X
X
0
MEM
DIV 26
FUSED DISC
DIV 23
X
X
X
DIV 26
MINIM
UNIT VOL
CONTROL
CONSTANT
CONSTANT
CONSTANT
CONSTANT
CONSTANT
POWER
SOURCE
NORMAL
NORMAL
NORMAL
NORMAL
NORMAL
PTS OF
CONN
ONE (1)
ONE (1)
ONE (1)
ONE (1)
ONE (1)
NOM UNIT
SIZE
(LxWxH, IN)
70x45x38
108x72x50
70x45x38
70x45x38
70x45x38
UNIT
WEIGHT
(LB)
800
2100
800
800
800
TAG
RTU-R.1
RTU -R.2
RTU -R.3
RTU -R.4
RTU R.5
DESIGN
BASIS
TRANE YHC
TRANE YHC
TRANE YHC
TRANE YHC
TRANE THC
LOCATION
ROOF
ROOF
ROOF
ROOF
ROOF
NOTES:
1. INSTALL IN COMPLIANCE WITH MECHANICAL AND ELECTRICAL CODE REQUIRED WORKING CLEARANCES.
2. PROVIDE PREMIUM EFFICIENCY MOTORS ON ALL FANS.
3. ALL UNITS TO BE HIGH EFFICIENCY.
4. PROVIDE SMOKE DETECTORS ON THE RETURN.
PACKAGED ROOFTOP AIR CONDITIONING UNIT SCHEDULE
5. PROVIDE THROUGH- THE -CURB ELECTRICAL CONNECTION.
6. PROVIDE HFC REFRIGERANTS; R407C, or R - 410
7. PROVIDE POWER EXHAUST WITH 100% MODULATING ECONOMIZER, SEE FAN SCHEDULE.
8. PROVIDE 100% ECONOMIZER WITH BAROMETRIC RELIEF.
. _ t �,.. ;)I� PU. I
Au 6 2658
Em - f I,akkvwita
SION
NOTES
1,2,3,5,6,8
1 THRU 7
1 THRU 7
1,2,3,5,6,8
1,2,3,5,6,8
Project Description
Briefly describe mechanical
system type and features.
Includes Plans
PROJECT IS A NEW BRANCH BANK. HVAC SYSTEM CONSISTS OF MULTIPLE
PACKAGED ROOFTOP GAS /ELECTRIC UNITS WITH 100% ECONOMIZERS & A
DUCTLESS SPLIT SYSTEM HEAT PUMP TO SERVE THE FRONT VESTIBULE.
Draw ings must contain notes requireing compliance w ith commissioning requirements - Section 1 416
RECEIVED
CITY OF TUKWILA
JUL 18 2008
PERMIT CENTER
4f'
(Description
I Scale
SeallSignature
Producfcn Copt
Project Number
32.2177.089
Schedules - Mechanical
? 2006 Gensler
z �'
1325 Fourth Ave, Suite 1515
Seattle, WA 98101
1'. 206.262.1010 F. 206.262.9865
M00.02
S outheenter Branch
Relocation
320 Strander Blvd
Tukwila, WA 98188
SERIAL NUMBER:
NRSP VERSION:
INCLUDES BULLETIN:
Gensler
Architecture, Design & Planning
Worldwide
G U MAC
engineers for a sustainable future"'
L
1 Rev Issue Date & Issue Description By Check
02/13/2008 Design Development MA / TM SPV / MAJ
04/30/2008 • CD Owner Review MA / TM SPV / MAJ
06/20/2008 Permit I Bid Set MA 1 TM SPV / MAJ
SEAL OF
q €NGR&EIING
QUALITY
av
WO
I Project Name
Southcenter Branch Relocation
51
FA
Job No.: 507023GEN
Contact: Michael Aliaga
www.glumac.com
WA0049
2.0
21A
[DrnrRes 03-24 -10
1 524 Fifth Avenue
Suite 300
Seattle, WA 98101
Telephone 206.654.2100
Facsimile 206.654.2121
CENTRAL
�8 �I
- ii RTU —R.
6 "—A 120
E\
26x20
16x12
NON
111 Ilk
III;
14x14
12
6 " —D; -110
FCU -1.1
CONTROLLER
14x10
6 " —A -120
24x. ---E -190
:1 12 " —B -220
6x6 —F -80
III HMI IMO ■�
12x6 —B -240 C)
12`' - B -240
viR( \11
VE
1008
CD 12x6 —B -240
1
A08.02
6 " —A -100
24x1
0
8 " —A
8 "--A -220
(TYP 14)
16x16 —E --1300
nnlirlrrrnrl Fr rnr . rrrmrnu
6 "--A -100
10 " —A-300
24x 6---E -150
RTU —R.3
14x14—E-600
14x12
14x12
KIUT -K.5
Scale
I Seal /Signature
I Project Number
32.2177.089
Description
? 2006 Gensler
1325 Fourth Ave, Suite 1515
Seattle, WA 98101
T. 206.262.1010 F. 206.262.9865
# �� rr�� }S y
tb� :23 x :AY L '� h iGA
S outhcen ter Branch
Relocation
320 Strander Blvd
Tukwila, WA 98188
SERIAL NUMBER: WA0049
NRSP VERSION: 2.0
INCLUDES BULLETIN: 21A
Gensler
C i l_U IrYA engineers r
en ineers for a sustainable future
Rev Issue Date & Issue Description By Check
02/13/2008 Design Development MA / TM SPV 1 MAJ
04/30/2008 CD Owner Review MA 1 TM SPV / MAJ
06/20/2008 Permit / Bid Set MA 1 TM SPV / MAJ
Project Engineer
Project Name
Southcenter Branch Relocation
Level 01 Construction Plan - Mechanical
Job No.: 507023GEN
Contact: Michael Aliaga
www.glumac.com
1524 Fifth Avenue
Suite 300
Seattle, W.A. 98101
Telephone 206.654.2100
Facsimile 206.654.2121
EXFIRES 03 ---24 10
ATM 12x10
1 / (j�x8— E-215
�`(F 6
120
a
0
110
a' i1-S
MO7.a1
R$
DUCT
-E
CE
C
ilk I
(TYP)
CE
VAULT
12x12 —E --380
12x10
12x10—E-200
"0 UP TO
RV —R.2
6 "---A -200
. I rrrTrrMEI =TIE=
6 " —A -120
\/A, LT
LC 6 6Y
" —A--80
SCALE: 1/4"— Q"
108
6"
6 " —A -160
LEVElARt TRUCTION PLAN - MECHANICA
8 " —A 300
T
mrlrm Tarn ran r irrrrn nlrrr l
8x8
WC
R
(ri
(TYP)
R<
V
18x10 —C -60
24x14 —E -1200
C.5
GENERAL NOTES
A. COORDINATE ALL MECHANICAL WORK WITH THE
ARCHITECTURAL, STRUCTURAL, AND ELECTRICAL
PLANS.
SHEET NOTES cip
OUTLINE OF ROOFTOP EQUIPMENT ABOVE.
2. DUCTWORK UP TO PACKAGED ROOFTOP UNIT. SEE
MO2.02. TRANSITION DUCT AS REQUIRED UP TO
SUPPLIED RTU.
. 12x12 UP TO EXHAUST FAN ON ROOF. FOR
CONT. SEE MO2.02
4. RS 84 RL UP TO CONDENSER ON ROOF.
5. DSD IN DUCT RISER FURNISHED BY DIV. 26 AND
INSTALLED BY DIV. 23.
6. SECURITY GRILLE LOCATION. SEE DETAIL
7 /MO7.01
7. MAINTAIN CLEARANCE FOR EQUIPMENT ACCESS PER
LOCAL CODE AND MANUFACTURE'S INSTRUCTIONS.
8. PROVIDE OFFSET TO STEP IN STRUCTURE (COORD
W/ ARCH AND STRUC).
9. COORDINATE SOFFIT CONSTRUCTION WITH ARCH.
10. ROUTE 6 "0 DUCT TO PRINTER CABINET AND
BALANCE TO 100 CFM.
11. HVAC EMERGENCY SHUTDOWN BUTTON. ACTIVATION
SHALL SHUTDOWN ALL MECHANICAL SYSTEMS.
COORDINATE WITH CONTROLS AND ELECTRICAL.
RECEIVED
CITY OF TUKWILA
JUL 18 2008
PERMIT CENTER
(6)
LLLLIUnuul U W1 L1 Iil:l 1119 LL1L1 Lu.tmV ■IL1L9 L1L1L- I MUM 9LL19
ROOF PLAN - MECHANICAL
SCALE: 1 /8 " -1' -0"
III 1.111111111INIIIIIII
IIIIIIIIIIIIIIIIII I I I 111111111111111111111111111111111111
8'
16'
- — t
GENERAL NOTES
A. COORDINATE ALL MECHANICAL WORK WITH THE
ARCHITECTURAL, STRUCTURAL, AND ELECTRICAL
PLANS.
SHEET NOTES GD
1. MAINTAIN EQUIPMENT CLEARANCES PER
MANUFACTURER'S INSTRUCTIONS.
2. REFRIGERANT LINES DOWN TO FCU.
3. PROPOSED LOCATION OF VFD. (COORD WITH
DIV 26).
RECEIVED
(r - v nF TUKWILA
, I I I 1 8 2008
RMiY CENTER
er
l� r <
Southcenter Branch
Relocation
320 Strander Blvd
Tukwila, WA 98188
SERIAL NUMBER: WA0049
NRSP VERSION: 2.0
INCLUDES BULLETIN: 21A
Gensler
Architecture, Design & Planning
Worldwide
C LU NIAC
engineers for a sustainable future'
L
1325 Fourth Ave, Suite 1515
Seattle, WA 98101
'1'. 206.262.1010 F. 206.262.9865
Rev Issue Date & Issue Description By Check
02/13/2008 Design Development MA / TM SPV / MAJ
04/30/2008 CD Owner Review MA I TM SPV / MAJ
06/20/2008 Permit / Bid Set MA I TM SPV / MAJ
SeallSignature
I Project Name
r
q DOEAING
QUALITY
Production Dept
Pro' Manager
Pmpd Engineer
Southcenter Branch Relocation
Project Number
32.2177.089
Description
Roof Plan - Mechanical
I Scale
MO2.02
? 2006 Gensler
B V s ty x
g4 X7 a`
Job No.: 501023G> N
Contact: Michael Aliuga
www.giumac.com
1524 Fifth Avenue
Suite 300
Seattle, WA 98101
Telephone 206.654.2100
Facsimile 206.654.2121
EXPIRES 03-24-10
1
MAN
R.C. PAD, BOLT
THRU LEVEL PAD
(TYP. OF 4)
6" EQUIPMENT
RAILS
NOTE:
EXTERIOR GAS LINE TO HAVE 3/4" ARMAFLEX INSULATION WRAPPED
WRAPPED W/ ALUMINUM JACKETING AND VAPOUR SEALED.
CONDENSER UNIT DETAIL
SCALE: NONE
CONDENSING
UNIT
ON ROOF
REFRIGERANT PIPING SCHEMATIC
SCALE: NONE
l
EMIR
aanr; ±urnr;,n;► nfitittlitt
WALL — FOR TYPE
REFER TO ARCH.
DRAWINGS
1/4" MIN. GAP —
FILL W/ CAULKING
PIPE SUPPORT AT 48" OC
(MAX), NEOPRENE COLLAR
CLAMPED TO STRUT.
PROVIDE 6" LONG SADDLE
AROUND INSULATION. (TYP)
TRAP AS REQUIRED BY
EQUIPMENT MANUFACTURER
LIQUID LINE SOLENOID
VALVE, SPORLAN
#ME— SERIES
1/2 "MIN. CLEARANCE
— TYPICAL ALL
AROUND
1/2" DEEP MASTIC SEAL
TYP. BOTH SIDES
GYPSUM VERMICULITE
OR PERLITE INSULATION
ALL AROUND
NOTE:
CU
REFRIGERANT LIQUID LINE
REFRIGERANT SUCTION LINE
INSULATED ENTIRE LENGTH
WITH ALUMINUM JACKET
EXTERIOR TO BUILDING.
RL X
NOTE: SIZE REFRIGERANT PIPING PER MANUFACTURER'S RECOMMENDATIONS.
SLEEVE
ti j/jl /jiMA ....:.
,r
><
RS-}
a
•
•
•
•
3/4" GAS & 3/8" LIQUID
REFRIGERANT LINES
TO FC-1
GROUND LEVEL
REFRIGERANT VALVE (TYP)
FILTER DRIER, SPORLAN
#C— SERIES WITH
#RCW— SERIES CORE. VERIFY
USE WITH EQUIPMENT
MANUFACTURER.
VIBRASORBER VIBRATION
ISOLATOR (TYP)
SIGHT GLASS, SPORLAN
SA— SERIES
THERMAL EXPANSION VALVE,
SPORLAN #OVE— SERIES, WITH
EQUALIZER. VERIFY USE WITH
EQUIPMENT MANUFACTURER.
DX
COIL
1/4" GAP ALL AROUND
CAULKING ALL
AROUND
22GA RETAINING
RING
1 //fv1IN.OVERLAP
STAINLESS STEEL
DUCT BAND
MASTIC SEAL
INSULATION
(IF REQUIRED)
Y. DUCT OR PIPE
I SULATION
( REQUIRED)
22 GA. RETAINING
FRAME OR RING
BOTH SIDES OF WALL
WHEN WALL IS HOLLOW,
USE 22 GA SHEET METAL
SLEEVE TO CONTAIN
INSULATION
1. IF WALL IS FIRE RATED THE PACKING & SEALING MATERIALS AND SYSTEM
INSTALLATION SHALL BE APPROVED BY THE FIRE MARSHALL.
2. COORDINATE SIZE & LOCATION OF PENETRATION WITH ARCHITECT AND /OR
STRUCTURAL ENGINEER.
DUCT OR PIPE
WALL PENETRATION - TYPICAL
SCALE: NONE
AS
REQUIRED
8"
MINIMUM
12"
MINIMUM
PIPING SIZE AS
INDICATED ON PLANS
NOTE:
SCALE: NONE
ADDITIONAL SUPPORTS
AS REQUIRED.
SHEETMETAL BOOT
WITH 1" ACOUSTICAL
LINING.
SUPPLY
DIFFUSER
SCALE: NONE
12"
MINIMUM
ti 4r4
4 10 .4
ROOF PENETRATION DETAIL
20 GAUGE SHEET METAL HOOD
WITH 1-1/2" DUCT LINER
INSIDE.
SHEET METAL OR FLEX—TUBE
COLLAR SEALED WATERTIGHT
SECURE WITH #10 SCREWS (2
PER SIDE).
SLOPE PIPES AWAY
FROM HOOD.
ROOFING BY ROOFING
CONTRACTOR.
3" CANT STRIP.
1. REFER TO ARCHITECTURAL PLANS FOR ROOF CONSTRUCTION.
2. ALL EDGES SHALL BE ROLLED AND TURNED DOWN, SHARP EDGES WILL NOT
BE ACCEPTED.
3. SEAL AS REQUIRED TO MAKE ALL JOINTS AND PENETRATIONS WATERTIGHT.
6 "MIN.
CONICAL TAP
ACOUSTICAL FLEX DUCT
S.M. DUCT
CEILING
SUPPLY AIR ACOUSTICAL BOOT DETAIL
UNIT
UNION
CONDENSATE DRAIN
LINE WITH 3" TRAP
1" HIGH STUB OPEN
TO ATMOSPHERE
5
2 1 /4" HILTI KIWK
FLEX SCREWS PER
HOLD DOWN CLIP
16 GAUGE "5" HOLD DOWN
CLIP, 6" LONG, 4—PER UNIT
(ONE PER SIDE)
INSULATION
COUNTER FLASHING BY
MECHANICAL CONTRACTOR.
FLASHING
ROOFING
ROOF
BLOCKING —
"M CANTS
3"MIN
SCALE: NONE
1/2" DIA STAINLESS
STEEL BARS. WELD AT
EACH INTERSECTION
2"x1/4" STAINLESS STEEL
FLAT BAR FRAME ASSEMBLY
NOTE:
SCALE: NONE
DUCT
NOTE: COORDINATE EXACT ROOF CONSTRUCTION MEANS AND METHODS
WITH ARCHITECTURAL AND STRUCTURAL PLANS.
1. SIZE & LOCATION SHOWN ON PLANS
2. ALL WELDED CONSTRUCTION
3. USE FOR VERTICAL OR HORIZONTAL INSTALLATION
SECURITY GRILLE
UNIT BASE RAIL
1/2" X 2" NEOPRENE
GASKET
2 0 1/4" HILTI KWIK
FLEX SCREWS PER
HOLD DOWN CLIP
16 GAUGE
METAL ROOF CURB
4 "X FRT DF#1
LEVELING BLOCK.
SHAPE TO LEVEL
UNIT.
3" FLEXIBLE DUCT
CONNECTION
ROOF CURB DETAIL - WOOD ROOF
1/2" THRU BOLT, LOCK
WASHER AND NUT AT 24" O.C.
2" ON CENTERS
IN BOTH DIRECTIONS
SECURE TO DUCT
OR STRUCTURE,
WITH SELF TAPPING
SECURITY FASTENERS
5" ON CENTER.
DUCT OR STRUCTURE
PLUG WELD FLUSH
TO SURFACE (TYP.)
FRESH AIR
WEATHERHOOD
FACTORY ROOF
CURB
SCALE: NONE
1/2" X 2" NEOPRENE
PAD ALL AROUND
1/4" HEX HEAD LAG
BOLT INTO CURB
(2 PER SIDE).
ROOF
DUCT
r
3" MIN
BLOCKING
S .A.
SCALE: NONE
rI
ROOF EXHAUST FAN
r
CONDENSATE DRAIN
D
R.A.
DUCT THRU ROOF
REFER TO MANE. FOR SIZE
FLEXIBLE
CONNECTION
ROOFTOP UNIT DETAIL
N
WOOD
2
07.01
EXHAUST FAN
NOTE: REFER TO ARCHITECTURAL PLANS FOR ADDITIONAL INFORMATION.
Arm
t
1�1 a
A
its,‘
INSULATION
ROOF
ROOFING BY ROOFING
CONTRACTOR
2" MIN HIGH FIRE
TREATED DOUGLAS
FIR #1 LEVELING
BLOCK. SHAPE TO
LEVEL UNIT.
BACKDRAFT DAMPER
18 GAUGE STEEL
CURB (8" HIGH MIN),
CANTS AND COUNTER
FLASHING BY MECHANICAL
CONTRACTOR.
1/2" THRU BOLT, WASHER
AND LOCKNUT (2 PER
SIDE) THRU 2" X 4" FLAT
BLOCKING AT PERIMETER.
NAIL WITH 16d NAILS AT
6" OC TO FRAMING.
Seal /Signature
SEAL OF
q ENGINEERING
QUAIJTY
Producton Copt
I Project Name
Southcenter Branch Relocation
Project Number
32.2177.089
ay;
EXPIRES 03 -24 -10
OPEN VENT TO ATMOSPHERE
WITH PERFORATED (MINIMUM OF
FOUR 1/8" HOLES) COPPER
CAP. CAP SHALL BE
REMOVABLE.
1% SLOPE (MIN)
TRAP DEPTH SHALL BE
3" MINIMUM OR 1"
GREATER THAN THE
TOTAL STATIC PRESSURE
OF THE SUPPLY FAN
(IN.WG.), WHICHEVER IS
GREATER.
NOTES:
CAPACITY SIZE
UP TO 20 TONS 3/4"
SCALE: NONE
MINIMUM 1" ABOVE FLOOD
RIM OF DRAIN PAN.
UNIT WITH COIL
DRAIN PAN
DIELECTRIC UNION
. TYPE "L" OR "M" COPPER
TUBING WITH WROUGHT
COPPER FITTINGS.
1. CONDENSATE PIPE TERMINATION SHALL BE LOCATED A MINIMUM OF 1" ABOVE
THE FLOOD RIM OF AN APPROVED TRAPPED RECEPTOR, LANDSCAPING AREA OR
OTHER LOCATION AS APPROVED BY THE AUTHORITY HAVING JURISDICTION.
2. ALL INTERIOR CONDENSATE DRAIN PIPING ABOVE CEILINGS SHALL BE INSULATED.
3. PROVIDE PIPE SUPPORTS AS REQUIRED TO MAINTAIN MINIMUM 1% SLOPE.
4. INSTALL TRAP PARALLEL TO UNIT, IF POSSIBLE.
5. MINIMUM CONDENSATE PIPE SIZES SHALL BE PER THE FOLLOWING TABLE
UNLESS LARGER SIZE IS SHOWN ON PLANS OR AS REQUIRED BY AUTHORITY
HAVING JURISDICTION AND /OR LOCAL BUILDING CODE REQUIREMENTS.
COOLING COIL CONDENSATE TRAP
USE 45' THROAT
AT TAP
SQUARE ELBOW WITH
TURNING VANES
ALLOWABLE IF DUCT
VELOCITY IS LESS THAN
1500 FPM
NOTE:
CENTERLINE RADIUS
EQUALS 1.5 TIMES "W".
NO T.V.'S REQ'D.
UNLESS OTHERWISE
NOTED
15' TYP.
30' MAX. W/
PRIOR APPROVAL
PROVIDE REDUCER
UPSTREAM OF
BRANCH INLET
SIZE OF DUCT DROP
TO MATCH NECK SIZE
OF GRILLE (TYPICAL)
SEE DETAILS.
NO T.V.'S REQ'D. ON
DUCT SIZES LESS THAN
16x10 IF DUCT VELOCITY
IS LESS THAN 1500 FPM.
USE RADIUS ELBOW IF
VELOCITY EXCEEDS 1500 FPM.
SPIN —IN FITTING
W /VD OR 45'
OVAL TAP
PROVIDE REDUCER
0 CONNECTION TO
GRILLE WHERE
BRANCH DUCT IS
OVERSIZED.
SEE DETAILS.
1. PROVIDE DUCT LINER & /OR EXTERNAL DUCT INSULATION AS NOTED ON
PLANS OR IN SPECIFICATIONS.
2. PROVIDE HANGERS AND SEISMIC BRACING PER SMACNA AND CODE
REQUIREMENTS.
10' MAX.
LENGTH. IF
OVER 10'
INCREASE ONE
DUCT SIZE.
TYPICAL LOW PRESSURE RETURN/
EXHAUST DUCT INSTALLATION DETAIL
SCALE: NONE
ROUND SHEET
METAL DUCT LESS
THAN 10' LONG
FLEX CONN.
5' MAX LENGTH
W /ONE 90' BEND
REDUCER TO MATCH
DIFFUSER NECK SIZE
IF BRANCH DUCT IS
OVERSIZED. LOCATE
AT CONNECTION TO
DIFFUSER.
ROUND SHEET METAL
DUCT. IF OVER 10'
LG. INCREASE ONE
DUCT SIZE
VD
TYPICAL ROUND
NECK DIFFUSER.
SEE DETAILS.
FLEX CONN.
5' MAX LENGTH
W /ONE 9O' BEND
CONICAL
SPIN —IN
FITTING
WITH V.D.
VD
TURNING VANES
REQUIRED ON
RECTANGULAR
DUCT SYSTEM
ELBOWS
SQ. TO ROUND
TRANSITION
VD
REDUCER
15' TYPICAL
30' MAX. W /PRIOR
APPROVAL
TYPICAL SQ. NECK
DIFFUSER. SIZE
OF DUCT DROP TO
MATCH DIFFUSER
NECK SIZE.
SEE DETAILS.
PLENUM
ROUND DUCT
<
5' MAX. LENGTH
DOWNSTREAM OF
REDUCER W/
ONE 90' BEND
TRANS.
FLEX
VD
N
45' OVAL
TAP OR
CONICAL
SPIN —IN
FITTING
SPLITTER DAMPER
WHERE SHOWN. DO
NOTE: NOT USE ON VAV
SYSTEMS
1. PROVIDE DUCT LINER & /OR EXTERNAL DUCT INSULATION AS NOTED ON RECEIVED
PLANS OR IN SPECIFICATIONS. CITY OF TUKWILA
2. PROVIDE HANGERS AND SEISMIC BRACING PER SMACNA AND CODE
REQUIREMENTS. JUL 1 8 2008
TYPICAL LOW PRESSURE SUPPLY
,'T CENT,
DUCT INSTALLATION DETAIL
SCALE: NONE
1325 Fourth Ave, Suite 1515
Seattle, WA 98101
'1'. 206.262.1010 F. 206.262.9865
Description
Details - Mechanical
!Scale
443
M07.01
? 2005 Gensler
R A 0
Southcenter Branch
Relocation
320 Strander Blvd
Tukwila, WA 98188
SERIAL NUMBER: WA0049
NRSP VERSION: 2.0
INCLUDES BULLETIN: 21A
Gensler
Architecture, Design & Planning
Worldwide
C «iiLU IVIPC r
engineers for a sustainable future's
Job No.: 507023G1;'N
Contact: Michael Aliaga
www.glumac.com
Rev Issue Date & Issue Description
L J
1524 Fifth Avenue
Suite 300
Seattle, WA 98101
Telephone 206.654.2100
Facsimile 206.654.2121
By Check
02/13/2008 Design Development MA / TM SPV / MAJ
04/30/2008 CD Owner Review MA / TM SPV I MAJ
06/20/2008 Permit 1 Bid Set MA / TM SPV / MAJ