Loading...
HomeMy WebLinkAboutPermit M08-196 - DIGITAL FORESTThis record contains information which is exempt from public disclosure pursuant to the Washington State Public Records Act, Chapter 42.56 RCW as identified on the Digital Records Exemption Log shown below. M08 -196 Digital Forest 12101 Tukwila International Boulevard RECORDS DIGITAL D- ) EXEMPTION LOG THE ABOVE MENTIONED PERMIT FILE INCLUDES THE FOLLOWING REDACTED INFORMATION Page # tode Exemption = 8rlef Explanatory DeSclriptiop �t�tutel ule The Privacy Act of 1974 evinces Congress' intent that social security numbers are a private concern. As such, individuals' social security Personal Information — numbers are redacted to protect those Social Security Numbers individuals' privacy pursuant to 5 U.S.C. sec. 5 U.S.C. sec. DR1 Generally — 5 U.S.C. sec. 552(a), and are also exempt from disclosure 552(a); RCW 552(a); RCW under section 42.56.070(1) of the Washington 42.56.070(1) 42.56.070(1) State Public Records Act, which exempts under the PRA records or information exempt or prohibited from disclosure under any other statute. Redactions contain Credit card numbers, debit card numbers, electronic check numbers, credit 13 Personal Information — expiration dates, or bank or other financial RCW DR2 Financial Information — account numbers, which are exempt from 42.56.230(5) RCW 42.56.230(4 5) disclosure pursuant to RCW 42.56.230(5), except when disclosure is expressly required by or governed by other law. DIGITAL FOREST 12101 TUKWILA INTERNATIONAL BL CANCELLED 10-13-08 M08 -196 Parcel No.: 0923049031 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: Value of Mechanical: $17,164.00 Type of Fire Protection: doc: IMC -10/06 CityNf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila. 12101 TUKWILA INTERNATIONAL BL TUKW DIGITAL FOREST 12101 TUKVVILAINTERNATIONAL BL , TUKWILAWA INTERNATIONAL GATEWAY WEST 12201 TUKWILA INTERNATIONAL BLVD , SEATTLE WA JARED SHEEKS 7717 DETROIT AVE SW , SEATTLE WA MACDONALD /MILLER FAC SOL INC PO BOX 47983 , SEATTLE, WA Contractor License No: MACDOFS980RU Furnace: <100K BTU 0 >100K BTU 0 Floor Furnace 0 Suspended/Wall/Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System.... 0 Air Handling Unit <10,000 CFM 0 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 0 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial/Industrial 0 MECHANICAL PERMIT EQUIPMENT TYPE AND QUANTITY * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 - 768 -3806 Phone: 206- 768 -4180 Expiration Date: 12/31/2008 DESCRIPTION OF WORK: DUCTWORK UPGRADE; INSTALL THREE DUCT BRANCHES CONNECTING INTOP EXISTING SUPPLY PLENUM. INSTALL FIRE/SMOKE DAMPERS AT EACH PLENUM CONNECTION. INSTALL FLEX DUCT CONNECTING TO DIFFUSERS M08 -196 08/11/2008 02/07/2009 Fees Collected: $372.50 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 3 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 M08 -196 Printed: 08-11 -2008 Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction performance of yvork. I am authorized to sign and obtain this mechanical permit. Signature: Print Name: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us n Permit Number: MO8 -196 Issue Date: 08/11/2008 Permit Expires On: 02/07/2009 Date: U- 1 t 4 o v Date: Dell / / o 'er This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC - 10/06 M08 -196 Printed: 08-11 -2008 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Parcel No.: 0923049031 Permit Number: M08 -196 Address: 12101 TUKWILA INTERNATIONAL BL TUKW Status: ISSUED Suite No: Applied Date: 07/28/2008 Tenant: DIGITAL FOREST Issue Date: 08/11/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ** *FIRE DEPARTMENT CONDITIONS * ** 9: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 10: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 11: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 12: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 13: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 14: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 15: These plans were reviewed by Inspector 0700. If you have any questions, please call Tukwila Fire Prevention Bureau at doc: Cond -10/06 M08 -196 Printed: 08 -11 -2008 (206)575 -4407. doc: Cond -10/06 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us * *continued on next page ** • M08 -196 Printed: 08-11 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doc: Cond -10/06 Date: mac-di J /OS( M08 -196 Printed: 08-11 -2008 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://wwwci.tukwila.wa.us w TUKWILA w Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: 0 q 2 309 ei 3 O Site Address: 1 3-lot ft w it h 1isi ki cir tZ A, IUD Suite Number: 4 1/ 0 Floor: Tenant Name: \ Ca 1 - 0..\ co e s+ - ^ D A , C p,cr i-t/ Property Owners Name: 7) i I al FOres + Mailing Address: Z! O 1 \ i,,. v ►kA ✓tt"C• ✓1 0 •1 - tg » 0 3 W D `� *.a rL a•. Li 1 / $ V. State Zip Name: SW/ - e e}` SV \<-S Mailing Address: - 1 - 1 1 1 10ekl `ci A Lit E -Mail Address: GENERAL CONTRACTOR (Contractor Infer nation for Mechanical (p ;4)`for Plumbing and Gas.P ping(pg ARCHITECT OF RECORD - a. ENGINEER OF `F Q,1■pplications\POrms- Applications On I.ine\3 -2006 - Permit Application.doc Revise& 44006 bh City Imped by Archit New Tenant: a State s to State Yes 1 ❑..No Day Telephone: (7.0(...) ? 65C 3 %d C. 5 w Se: .e L f\ 9 t O C7 City State Zip Fax Number: Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: � �� p"r`ton Date: Zip ans must be Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: z p Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: ''`�.F tax Number: Zip Page 1 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler/Compressor: Qty Furnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 3 0-3 HP/100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser 3-15 HP/500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15-30 HP/1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30-50 HP/1,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+11P/1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator — Comm/Ind Other Mechanical Equipment MECHANICAL PERMIT INFORMATION - 206-431-3670 MECHANICAL CONTRACTOR INFORMATION Company Name: AA. Ot PAAlltr Mailing Address: — in ekr 41 Contact Person: 3 kiUL S Sw aaatt, City wA ci v i c:1(o State hp Day Telephone: ) to4i - .3S( 0(z Fax Number: Expiration Date: 1 31 — E-Mail Address: Contractor Registration Number: IA 1t,73 0 P S 9 tZ,c) Valuation of Project (contractor's bid price): $ 1 1 ) 4:P9 — Scope of Work (please provide detailed information): SRL) rk (),_9 b rovil2 ins-I '1 duck r-o.eNti-Le...t C vl bPLP_C+rrIl r\4" -e,k■thr‘ stA ePui \ ne■ ,1 f-- Go r■-k- mi‘ PVC CCP–A—Ct co fvelf 3 Use: Residential: New .... 0 Replacement .... 0 Commercial: New .... 0 Replacement .... Fuel Type: Electric t Gas ....0 Other: Indicate type of mechanical work being installed and the quantity below: Q, ApplicationsIFonns•Applications On LineO-2006 - Permit Appliestionsloe Revised: 4-2006 bh Page 4 of 6 PERMIT API'LICATION N licable to all Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDIN OWNER I • HORIZED AGENT: Signature: Date: --- /l / O1 Print Name: A2.t,W �0 1 1 /� Day Telephone. - -) 7 6 cZ V.I.") Q Mailing Address: — 1 - 1 1 \ �R.�CY-ri 1� A ti & S W a_G∎'fr ,q 1 1 - )44 i 2 j ©to City State Zip Date Application Expires: -) - 0 Date Application Accepted: Q: Applications0Porma•Appliutions On r.ine13.2006- Permit Appiieation.doc Revised: 4 -2006 bh Staff Initials: , Page 6 of 6 Payee: MACDONALD MILLER ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www. ci. tukwila. wa. us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1807 372.50 RECEIPT Parcel No.: 0923049031 Permit Number: M08 -196 Address: 12101 TUKWILA INTERNATIONAL BL TUKW Status: PENDING Suite No: Applied Date: 07/28/2008 Applicant: DIGITAL FOREST Issue Date: Receipt No.: R08 - 02762 Payment Amount: $372.50 Initials: WER Payment Date: 07/28/2008 01:47 PM User ID: 1655 Balance: $0.00 Account Code Current Pmts 000.322.102.00.0 298.00 000/345.830 74.50 Total: $372.50 5367 07/28 9710 TOTAL 372.50 doc: Receiot -06 Printed: 07 -28 -2008 J' October 21, 2008 Dear Ms. Doll: City of Tukwila Department of Community Development Jack Pace, Director Darla Doll MacDonald Miller PO Box 47983 7717 Detroit Avenue SW Seattle, WA 98146 -7983 RE: Permit Fee Refund Enclosed is a check in the amount of $238.40 which equals 80% of the permit fee paid for the project located at 12101 Tukwila International Bl, Tukwila, Washington. Per your request, your permit has been cancelled. If you have any questions, please feel free to contact our office at 206 - 431 -3670. Sincerely, Brenda Holt, Permit Coordinator encl Permit File No. M08 -196 H:\Documents\L.etters\M08 -196 - refund letter.doc bh Jim Haggerton, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 r. ...:;;-`,:,'::„..,,, , &P:O..NU.R413ER;. ,. f ..e -.-.,;;,- `- .. -- '-::;:!.. -' ,s., OESCRiF : ',..... ,: ,;'..i.` . Y. , ' ' '-!'..,...;*, - ,7 ...- , . ..? 102008303 10/15/2008 *** ****** 238 40 . 80% REF. PERMIT M08-196 238.40 CITY OF TUKWILA, WA 98188-2544 *rt ' THE FACE OF THIS DOCUMENT HAS A•COLORED BACKGROUND =NOT A WHITE.,BACKGROUND`'Z' PAY CITY OF .TUKWILA 6200 Southcenter Boulevard TukwilalA/A 98188-2544 • Two Hundred Thirty•Eight•Dollars and Fcirty Cents • TO THE MACDONALD MILLER FAC SOLUTIONS ' ORDER PO BOX 47983 7717 DETROIT AV SW OF • SEATTLE, WA 98146-7983 ACCOUNTS PAYABLE CHECK PLEASE DETACH BEFORE DEPOSITING .•• . PAYABLE THROUGH U.S. BANK . . • 151 Andover Park East • • Tukwila. WA 98183 THE BACK OF THIS DOCUMENT HAS AN ARTIFICIALINATERMARICHOLD ATANANGLE 19-10 1250 Memo October 14, 2008 To: Laurie Anderson From: Brenda Holt Re: M08 -196 Xc: File No. M0 8-196 H:1Documentsletters\MO8 -196 - refund memo.doc bh Please refund the following fees to MacDonald Miller. The property owner elected to not have MacDonald Miller do the work. Permit Fee (80 %) $238.40 Please make the check out to them and I will forward it to them: MacDonald Miller PO Box 47983 Seattle, WA 98106 City of Tukwila Permit Center Niq6 ariaioo 1A 17 -21� Doll — 7(3 -9'aD 77 l f. of Ave- cJ She W4 e I ' DfO A4U Bob 8eyi e ctcid I/)7)/o0 - l9� Du. e -6 cle` Sct,e o n e✓ b6 P�°9e+ 2 (ec -fed 40 ND lAY Jet:( u S. (ea Se C-04-AA ce. 'Plea re y (ee s AkJocct.e4 im,/o/quwc 007 i rA/1/1 " 4 )146-1 10 -13 -09 RECSVED clTV OF TUKWILA OCT 13 2O13 PERMIT CENTER ACTIVITY NUMBER: M08 -196 DATE: 07 -28 -08 PROJECT NAME: DIGITAL FOREST SITE ADDRESS: 12101 TUKWILA INTERNATIONAL BL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS' B [ riding i• 'vision Complete Comments: Ij Documents/routing slip.doc 2 -28 -02 • • PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Public Works ❑ 0'100 PrW li 1 Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Incomplete Approved 1 1 Approved with Conditions 1 Notation: REVIEWER'S INITIALS: n Planning Division Permit Coordinator DUE DATE: 07 -29 -08 Not Applicable Permit Center.Use Only' • a . `' ..'' INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping El PW ❑ Staff Initials: TUES/THURS RO ING: Please Route Structural Review Required ❑ No further Review Required DATE: DUE DATE: 08-26-08 Not Approved (attach comments) n DATE: Permit Center Use Only' • CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Name Role Effective Date Expiration Date TURLEY, DOUGLAS CHIEF EXECUTIVE OFFICER 02/13/2008 Bond Amount TURLEY, DOUGLAS CHIEF OPERATING OFFICER 02/13/2008 023006951 SIGMUND, FREDRIC PRESIDENT 12/31/2002 HACK, RICHARD SECRETARY 02/13/2008 KOPET, TYLER TREASURER 12/31/2002 LOVELY, STEVE C VICE PRESIDENT 12/31/2002 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 LIBERTY MUTUAL INS CO 023006951 12/11/2002 Until Cancelled $12,000.00 12/31/2002 Untitled Page General /Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. MACDONALD /MILLER FAC SOL INC Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type CORPORATION Parent Company MACDONALD /MILLER FAC SOL INC 2067684180 PO BOX 47983 SEATTLE WA 98106 KING UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Separation Date Previous License Next License Associated License Specialty 1 Specialty 2 602254260 ACTIVE MACDOFS980RU CONSTRUCTION CONTRACTOR 12/31/2002 12/31/2008 DIVCOI *988RC GENERAL UNUSED Business Owner Information Bond Information Insurance Information I Company I • I Effective I Expiration ICancelllmpairedl Page 1 of 2 Received https: // fortress .wa.gov /lni/bbip/Detail.aspx ?License= MACDOFS980RU 08/11/2008 DUCT LEGEND DESCRIPTION SYMBOL DESCRIPTION SYMBOL BARE SHEETMETAL ROUND SHEETMETAL WRAPPED W/ INSULATION (2 ") 120W 14/12 SOUNDLINE SHEETMETAL (1" LINING) CLEANROOM QUALITY DUCTWORK 14/12 C 14 12 S SHEETMETAL WRAPPED W/ INSULATION (2 ") BARE FLAT OVAL SHEETMETAL 14/12 14/12 W BARE ROUND SHEETMETAL FLAT OVAL FLAT SHEETMETAL W/ INSULATION (2 ") 14 /fi 20 4 EXPOSED QUALITY SHEETMETAL DUCTBOARD (1" FIBERGLASS) 14/12 DB 14 12 0 EXAMPLE OF NEW EXAMPLE OF NOT IN CONTRACT (NIC) 14/72 ..__..._ 14 12 EXAMPLE OF DEMO FLEX DUCT EXAMPLE OF EXISTING FLEX CONNECTOR 14 %'12 co O 0 cs,1 (• 3� 0 - L LL Plar review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and + itions is acknowledged: By . r Date: O X 1) City of Tukwila BU]LDINO DIVISION ......_______,...,.......____ REVI No changes shall be made to the scope of work without prior approval of Tukwila Building Division. N OTE: Revisions will require a new plan submittal and may include additional plan review fees. 1 YetvibivL FOR CODE COMPLIANCE. AP µ 4DVED AUG - ?O City Of Tukwila y 3 1 y ,q � D x y SEPARATE PERMIT REQUIRED FOR: D echanical el ectrical (Plumbing ['Gas Piping City of Tukwila BUILDING DIVISION ABBV FULL NAME A AC AFF AL BDD BOB BOD BOTT BTU BTUH BWG BWR C CAP CC CFM CHWR CHWS COMB CONN CWR CWS DB DIFF DMPR DN EC EGC EER ELEV EMS COMPRESSED AIR LINE AIR CONDITIONING UNIT ABOVE FINISHED FLOOR ALUMINUM BACKDRAFT DAMPER BOTTOM OF BEAM BOTTOM OF DUCT BOTTOM BRITISH THERMAL UNITS BRITISH THERMAL UNITS PER HOUR BOTTOM WALL GRILLE BOTTOM WALL REGISTER CONDENSATE CAPACITY CONTROLS CONTRACTOR CUBIC FEET PER MINUTE CHILLED WATER RETURN CHILLED WATER SUPPLY COMBUSTION CONNECT CONDENSER WATER RETURN CONDENSER WATER SUPPLY DUCT BOARD DIFFUSER DAMPER DOWN ELECTRICAL CONTRACTOR EGGCRATE ENERGY EFFICIENCY RATIO ELEVATION ENERGY MANAGEMENT SYSTEM SYMBOL DESCRIPTION- POWERED 1 1/2 HOUR VERTICAL COMBINATION FIRE /SMOKE FSD Yz GREENHECK FSD 212 (2000 FPM) OR EQUAL GREENHECK FSD 312 (3000 FPM) OR EQUAL HFSD rFSD FSD HFSD MD AD SD ` � . SMOKE DAMPER GREENHECK SMD 202 OR EQUAL SMOKE CONTROL MOTORIZED DAMPER GREENHECK SMD 301 OR EQUAL SCD SC INTERLOCK WITH FIRE ALARM BY ELECTRICAL CONTRACTOR GENERAL NOTES: COMBINATION FIRE /SMOKE DAMPER REQUIREMENTS (UNLESS OTHERWISE NOTED): - CLASS II - 165° FUSIBLE LINK - FAIL - CLOSE, 120V ACTUATOR - ACTUATOR BY MECHANICAL CONTRACTOR, WIRING BY ELECTRICAL CONTRACTOR - INTERLOCK TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR NAME TITLE TM0.01 SCHEDULES - HVAC TM2.04 4TH FLOOR PLAN - HVAC TM6.01 DETAILS - HVAC TITLE PROJECT ENGINEER ACCOUNT EXECUTIVE SHEET METAL FOREMAN 1 1/2 HOUR HORIZONTAL COMBINATION FIRE /SMOKE GREENHECK FSD 212 (2000 FPM) OR EQUAL GREENHECK FSD 3 (3000 FPM) OR EQUAL 1 1/2 HOUR TUNNEL CORRIDOR COMBINATION FIRE /SMOKE GREENHECK CFSD 212 -1 OR EQUAL 3 HOUR VERTICAL COMBINATION FIRE /SMOKE GREENHECK FSD 231 OR EQUAL 3 HOUR HORIZONTAL COMBINATION FIRE /SMOKE GREENHECK FSD 231 OR EQUAL MOTORIZED CONTROL DAMPER GREENHECK VCD -23 OR EQUAL ACCESS DOOR 18" x 18" MINIMUM THROUGH BUILDING CONSTRUCTION BY GENERAL CONTRACTOR NAME JARED SHEEKS STEVE FLINK LARRY HARBISON HVAC ABBREVIATIONS ABBV FULL NAME ESP EXTERNAL STATIC PRESSURE EXH EXHAUST EXTR EXTRACTOR FAC FIRE ALARM CONTRACTOR FD FIRE DAMPER FLA FULL LOAD AMPS FOB FLAT ON BOTTOM FOT FLAT ON TOP FSD FIRE SMOKE DAMPER G GAS LINE GALV GALVANIZED GC GENERAL CONTRACTOR GPM GALLONS PER MINUTE GR GRILLE GWB GYPSUM WALL BOARD HG HOT GAS LINE HP HORSE POWER HWR HOT WATER RETURN HWS HOT WATER SUPPLY ID INSIDE DIMENSION INT INTERLOCK LIQ LIQUID LINE M -M MACDONALD- MILLER MBH ONE THOUSAND BTUH MC MECHANICAL CONTRACTOR MCA MINIMUM CIRCUIT AMPACITY MD MOTORIZED DAMPER MIN MINIMUM MT MOUNT MUA MAKE -UP AIR NOM NOMINAL DAMPER LEGEND SYMBOL FD FIFD FD HFD 13 -�-- FD BDD BAR DRAWING SHEET INDEX NAME TITLE CONTACT LIST COMPANY MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER SCOPE OF WORK ABBV FULL NAME OSA OUTSIDE AIR OBD OPPOSED BLADE DAMPER OD OUTSIDE DIMENSION RA RETURN AIR REG REGISTER (GRILLE WITH DAMPER) REQ'D REQUIRED RIO ROUGH IN ONLY SA SUPPLY AIR SCD SD SL SM SP SS SSSC STL TOS TV TWG 'MR TYP UND VD VFD SMOKE CONTROL DAMPER SMOKE DAMPER SOUND LINING SHEET METAL STATIC PRESSURE START /STOP SOLID STATE SPEED CONTROLLER STEEL SUB SUCTION LINE SUSP SUSPENDED T'STAT THERMOSTAT TC TEMPERATURE CONTROL TOD TOP OF DUCT TOP OF STEEL TURN VANES TOP WALL GRILLE TOP WALL REGISTER TYPICAL UNLESS NOTED OTHERWISE VOLUME DAMPER VARIABLE FREQUENCY DRIVE VOLTAGE PHASE & DUCT DIAMETER DESCRIPTION -NON POWERED 1 1/2 HOUR CURTAIN STYLE VERTICAL FIRE DAMPER GREENHECK DFD 150 OR EQUAL 1 1/2 HOUR CURTAIN STYLE HORIZONTAL FIRE DAMPER GREENHECK DFD 150 (HORIZONTAL MOUNT) OR EQUAL 3 HOUR CURTAIN STYLE VERTICAL FIRE DAMPER GREENHECK DFD 350 OR EQUAL 3 HOUR CURTAIN STYLE HORIZONTAL FIRE DAMPER GREENHECK DFD 350 (HORIZONTAL MOUNT) OR EQUAL CEILING RADIATION DAMPER GREENHECK CRD -2 OR EQUAL BACKDRAFT DAMPER GREENHECK WD 330 (VERT) OR WD -100 (HORIZONTAL) OR EQUAL BAROMETRIC RELIEF DAMPER (.05 OPNG PRESSURE SHOWN) RUSKIN CBD2 NO SUBSTITUTE ALLOWED VOLUME DAMPER SHOP FABRICATED, W/ LOCKING QUADRANT FIRE DAMPER REQUIREMENTS: - BLADES our 0= AIRSTREAM ON MEDIUM PRESSURE DUCTS - 165 F FUSIBLE LINK - CLASS II PHONE NUMBER 206 - 768 -3806 253 -680 -3172 206- 768 -4294 E -MAIL iKpst.sheeks@macmiller.com steve.iEnk macmiller.com larry.harbisann macmiller.com DC -3 DUCTWORK UPGRADE: PROVIDE AND INSTALL 3 NEW DUCT BRANCHES IN DC -3 CONNECTING INTO EXISTING SUPPLY PLENUM. INSTALL FIRE /SMOKE DAMPER AT EACH PLENUM CONNECTION. CONNECTION TO FIRE SURPRESSION SYSTEM IS BY FIRE ALARM CONTRACTOR. INSTALL FLEXIBLE DUCT CONNECTING SUPPLY BRANCHES TO DIFFUSERS ABOVE SERVER RACKS. AIR BALANCE NEW AIR OUTLETS. HVAC GENERAL NOTES 1. THE HVAC SYSTEM FOR THIS PROJECT IS BASED ON THE FOLLOWING CRITERIA: ROOF "U" VALUE (BTUH /S.F. °F) = N/A WALL "U" VALUE (BTUH /S.F. °F) = N/A FLOOR "U" VALUE (BTUH /S.F. "F) = N/A GLASS "U" VALUE (BTUH /S.F. °F) = N/A GLASS SHADE COEFF. = N/A LIGHTING (WATTS /S.F.) = N/A MISC. EQUIP. (WATTS /S.F.) = N/A PEOPLE DENSITY (S.F. /PERSON) = N/A COOLING INDOOR DESIGN TEMP (°F) = N/A COOLING OUTDOOR DESIGN TEMP ( °F) = N/A HEATING INDOOR DESIGN TEMP ( °F) = N/A HEATING OUTDOOR DESIGN TEMP ( °F) = N/A 2. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OE1 SET WHICH MAY BE REQUIRED. THE FIVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. 3. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2006 EDITIONS OF THE INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE AND STATE AND LOCAL CODES AND ORDINANCES. 4. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 6 OF THE 200:1 IMO AND WITH CURRENT SMACNA STANDARDS. EARTHQUAKE BRACE ALL DUCTS 28" DIA AND LARGER WHICH ARE SUSPENDED MORE THAN 12" BELOW STRUCTURAL_ SYSTEM. 5. JOINTS OF MEDIUM AND HIGH VELOCITY DUCT SYSTEMS SHALL BE SEALED WITH GASKETS OR LISTED MASTIC TYPE DUCT SEALANT. 6. DUCTS SHALL BE INSULATED AS INDICATED ON PLANS, PER 2006 WSEC. - DUCT WRAP, WHERE INDICATED, SHALL BE 1 1/2" 0.75 LB /CU FT FIBERGLASS DUC I INSULATION WITH A FACTORY APPLIED REINFORCED ALUM. FOIL VAPOR BARRIER (R -4.2 MIN.). - SOUND LINING, WHERE INDICATED, SHALL BE 1" 1.5 LB /CU FT FIBERGLASS DUCT LINING COATED TO PREVENT FIBER EROSION AT VELOCITIES UP TO 6000 FPM (R-4.2 MIN.). - DUCT BOARD, WHERE INDICATED, SHALL BE 1" RIGID FRK FACED EL 475 FIBERGLAS DUCT BOARD SYSTEM, UL 181 LISTED AS A CLASS 1 AIR DUCT (R-4.3 MIN.). 7. FLEX DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER, 1 1/2" FIBERGLASS INSULATION, AND NON - PERFORATED INTERIOR LINER WITH WIRE HELIX. DUCT SHALL BE A UL 181 LISTED CLASS 1 AIR DUCT. FLEX DUCTS SHALL ONLY BE USED ' 'HERE SHOWN AND SHALL NOT EXCEED 8' IN LENGTH UNLESS NOTED OTHERWISE. 8. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SEC [ION 1621 OF THE 2006 IBC. 9. PROVIDE FIRE DAMPERS, SMOKE DAMPERS AND FIRE /SMOKE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.5 OF THE 2006 IBC. PROVIDE CEILING FIRE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.6.2 OF THE 2006 IBC. INSTALL FIRE DAMPERS SMOKE DAMPERS AND FIRE /SMOKE DAMPERS IN ACCORDANCE WITH THE MANUFACTURERS INSTRUC TIONS, THE TERMS OF THEIR LISTING, AND THE REQUIREMENT OF THE CODE. 10.PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 11 .PROVIDE RETURN DUCT SMOKE DETECTOR AUTOMATIC SHUT DOWN OF ALL NEW HEATING, COOLING, OR VENTILATION EQUIPMENT MOVING IN EXCESS OF 2000 CFM IN ACCORDANCE WITH SECTION 606 OF THE 2006 IMC. POWER AND INTERLOCK WIRING WITH THE BUILDING FIRE ALARM SYSTEM IS BY THE ELECTRICAL CONTRACTOR. 12, HVAC EQUIPMENT, VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNL ESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRAC FOR, 13.HEAT TRACING OF PIPING, WHERE INDICATED, SHALL BE PROVIDED AND INSTALLED BY THE HVAC CONTRACTOR. THE HVAC CONTRACTOR IS TO COORDINATE THE HEAT TRACE POWER WIRING WITH THE ELECTRICAL CONTRACTOR. 14.MOTOR STARTERS NOT LISTED AS BEING PROVIDED IN THE FIVAC EQUIPMENT SCHEDULES ARE TO BE PROVIDED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. 15. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER. RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM, INCLUDING SIZES, AND THE TERMINAL AIR AND WATER DESIGN FLOW RATES. 16.OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE: 'SUBMITTAL DATA, NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY, HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INF +)RMATION AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM, 17.COMMISSIONING IS REQUIRED ON THIS PROJECT IN ACCORD WITH WASHINGTON STATE ENERGY CODE (WSEC) SECTION 1416 AND WITH LEED NC -2.1 FUNDAMENTAL BUILDING SYSTEMS COMMISSIONING AND ADDITIONAL COMMISSIONING. 18.A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED IND FILED WITH THE OWNER. 19.FOR ALL "SEALED AIR TIGHT" SHAFTS OR ROOMS, THE FOLLOWING MUST OCCUR: - ALL VERTICAL JOINTS INSIDE THE SHAFT SHOULD BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT, INCLUDING THE SHAFT CORNERS (BY GC). - TOP AND BOTTOM WALL TRACKS SHOULD BE CAULKED ALONG THEIR ENTIRE LENGTH (BY GC). ANY FLOOR DECKING PERPENDICULAR TO THE SHAFT SHOULD BE CAULKED. FILLING WITH ROCK WOOL OR FIRESAFING ( "MONOCOAT ") IS NOT ACCEPTABLE (BY GC). - ANY PENETRATIONS OF THE SHAFT CONSTRUCTION (DUCTWORK, CONDUIT, PIPING') SHOULD BE SEALED WITH FIRE CAULKING ON BOTH SIDES OF THE PENETRATION. - USE SECTION 909.5 OF THE 2006 IBC FOR MAXIMUM ALLOWABLE LEAKAGE AREA, FOLLOWING THE GUIDELINES FOR SMOKE BARRIER CONSTRUCTION. - ALL DOORS MUST BE PROVIDED WITH TIGHT FITTING GASKETS, AND OPEN AGAING T THE DIRECTION OF ROOM /SHAFT PRESSURE. 20.DAMPERS USED FOR OUTDOOR AIR INTAKE, EXHAUST, OR RELIEF SHALL HAVE THE FOLLOWING MAXIMUM LEAKAGE RATES AT 1" W.G. (PER AMCA STANDARD 500): MOTORIZED DAMPERS: 10 CFM /S.F. GRAVITY DAMPERS: 20 CFM /S.F. (40 CFM /,.F. FOR DAMPERS SMALLER THAN 24 INCHES IN EITHER DIMENSION). 21.OUTSIDE AIR INTAKE, EXHAUST, AND RELIEF DAMPERS SERVING CONDITIONED SPACES MUST BE MOTORIZED (FAIL CLOSED) PER WSEC 1412.4.1, EXCEPT AS ALLOWED BY WSEC. 22.RETURN AIR SHAFTS TO BE CONSTRUCTED BY THE G.C. TO WITHSTAND A MINIMUM 20 PSF DIFFERENTIAL PRESSURE ACROSS THE WALL. DIFFERENTIAL PRESSURE IS BASED UPON THE MAXIMUM STATIC PRESSURE CAPABILITY OF FAN SYSTEMS SUBJECT TO AUTOMATIC DAMPER CLOSURE. 23.PRESSURIZATION SHAFTS SHALL BE CONSTRUCTED BY THE G.C. AS FOLLOWS: - SHAFTS SERVED BY PRESSURIZATION FANS RATED UP TO 1" STATIC PRESSURE 10 BE CONSTRUCTED TO WITHSTAND 10 PSF DIFFERENTIAL PRESSURE. - SHAFTS SERVED BY PRESSURIZATION FANS RATED BETWEEN 1 -2.5" STATIC PRESSURE TO BE CONSTRUCTED TO WITHSTAND 20 PSF DIFFERENTIAL PRESSURE. - FOR SHAFTS SERVED BY PRESSURIZATION FANS RATED ABOVE 2.5" STATIC PRESSURE, CONTACT MECHANICAL ENGINEER. APN # 0923049309 LEGAL DESCRIPTION LEGAL DESCRIPTION: BEGIN NW CORNER OF NE 1/4 OF SE 1/4 TH S 89 -16 -35 E 100 FT TH 5 24 -13 -53 E 567.42 FT TO POINT OF BEGINNING TH N 66 -35 -01 E 120.47 FT TH N 20 -23 -23 W 27.58 FT TH N 65 -32 -34 E 165 FT TO POINT ON WLY RAN LINE OF PRIMARY STATE HIGHWAY NO 1 (SR 99) SOUTH 118TH ST TO JCT SSH NO 1 -K APPROVED JULY 23, 1957 TH FOLLOWING SAID WLY RJW LINE 5 24 -27 -26 E 110.84 FT TH FOLLOWING SAID WLY RAN LINE N 65- 32••54 E 10 FT TH FOLLOWING SAID WLY RIM'/ LINE 5 24 -27 -26 E 200 FT TH FOLLOWING SAID WLY RAN LINE N 65 -32 -34 E 20 FT TH FOLLOWING SAID WLY RAN LINE S 24 -27 -26 E 126 FT TH FOLLOWING SAID WLY R/W LINE ALONG ARC OF 2805 FOOT RADIUS NON TANGENT CURVE TO RIGHT CENTER BEARING 5 65 -32 -34 W THRU C/A OF 0 -12 -18 DISTANCE OF 10.03 FT TH 8 65 -30 -25 W 199.33 FT TH N 22-47-01 W 21.44 FT TH S 63- 32-48 W 62.13 FT TH S 65 -46 -07 W 58.17 FT TH N 24 -13 -53 W 402.19 FT TO POINT OF BEGINNING LOT C OF CITY OF TUKWILA BOUNDARY LINE ADJUSTMENT NO L98 -0033 RECORDING NO 9810059013 12101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA VICINITY MAP Mob - lib E D 008 �NTEF MacDonald-Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206- 763 -9400 Fax: 206-767-6773 Www.macmiiier.com WA Lic No: MACOOFS980RU DIGITAL FOREST DATA CENTER EXPANSION DC -3 DUCT LAYOUT 12101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA SCHEDULES & NOTES HVAC 1 ENGINEER: J SHEEKS CHECKED BY: B GEZON CAD: J SHEEKS LAST REVISED: 07 -25 -08 DATE PLOTTED: 07 -25 -08 ISSUE DATE: DRAWING NUMBER: 0- 1490 - 7386578 -00 - 00 ISSUED FOR PERMIT SHEET NUMBER: TM I dr)1 CO 0 0 0 c 0 0 0) C`d cts, C 01 1 A c D 1 1.5 Fr 1 4 1-1 r L 2 ) 1 FIRE/SMOKE DAMPER ------ -- ------- : 111 — 1 - „ ----- ---------- - --- - --- ----------------- [ I I \—/ \ \ .„ ----- _ ----- N L.. I I t 3 '1 I — - f1 - ,,/ 11 , „, —..... i il . - ...., 1 I ty --1 ,:,- ,--- --.„ :-„: \/ e 11 / ''. N ,, \ 1! „ \ '1 \ 11 • 71 \II r •-•••• --- It , 1 t. ,.... tk'''''''' --------------------------------- tttt _,.. -------- 3 11 __- - 1, " 4 ---- ------- ------ SCALE: 1 2 = 4 1 • , : I (1 (0 I ISOMETRIC VIEW - HVAC I "t 2 i . --- „I A l 44 0 4 SA", BALANCING DAMPER I* 4*4 42"x28" FIRE SMOKE DAMPER 32"x28" FIRE SMOKE DAMPER RUSKIN TYPE FSD36 RUSKIN TYPE FSD36 INTERLOCK TO FIRE SURPRESSION SYSTEM INTERLOCK TO FIRE SURPRESSION SYSTEM I BY FIRE ALARM CONTRACTOR BY FIRE ALARM CONTRACTOR ,_„„.. - . -- „, ' 111 .7 11 t 11--1 117 -. , --- „=....:z111117- --- --- ---- ------- -------- -------- - -- - - r -- . FUTURE I , \ .F. (.5) 1 ---, 1 ,_ i 1 , r —I I . ,)- .f 1 : 1 L : I i t t , F7f."- 1 - 1 1 I t r -..,‘,...-.- _.___, „ 22"x48" EGGCRATE GRILLES 1950 CFM TYPICAL SEE TM6.01 8s6 FLEX DUCT THERMAFLEX S—TL 22"x48" DIFFUSER FSD BLANK— FF BETWEEN CABINETS 1 180 • FLEX (TYPICAL) THERMAELEX S—TL AISLE SEPARATION CURTAIN CONSTRUCTED OF HEAVY WEIGHT PLASTIC EXTEND FROM TOP OF DIFFUSER CAN TO 24" BELOW DECK .,111 • 3 (4) 5 kW CABINETS & (8) 10 kW CABINETS 111 ------ 1 I 11 11 1 t; FUTURE RETURN DROP (12) 5 kW CABINETS I (TYP 2) i SCALE: 1 8 = 1 —0 --. - -- -- --- ----- --- ----------- . . ----- --------------- -- ^ .....„„.„„„.,,, / [d I -,-"-- 2 1 1 1 r t, s'),:', III / 1, 111 -------- -'' --- 1 / '''', / t, ', ,,,, i t• t \ /3 .1 SUPPLY DROP INTO PLENUM 22"x48" EGGCRATE GRILLES 1200 CFM TYPICAL SE 14 6.01 _ (, 0 C4.4 71- 1 4 1 40 i 1 Fbu , N C 4 mis Spry**, cs 4- 3440 ot ,, 1 .de.ve,leifee( 04- (2 use CP-s.S C.,. pet- 5.00titiok) etter,3 z 4TH FLOOR PLAN - HVAC II -7 !M`t1'. 1 I . 1 , 7 ) --r,t.t .4. .." / 111 , ■ V -,,, T - -I IN r . 11 11 I 7.5 ••• I r 1T • • B A 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206-763-9400 Fax: 206-767-6773 www.rnacmiller.corn WA Lk No: MACDOFS980RU REVISIONS: DATE DIGITAL FOREST DATA CIINTER EXPANSION DC-3 DUCT LAYOUT 12101 TUKWILA INTL BLVD TU MI _A, WA MacDonald-Miller FACILITY SOLUTIONS 4TH FLOOR PLAN — HVAC ENGINEER: LAST REVISED: J SLEEKS 07-25-08 CHECKED BY: DATE PLOTTED: B GEZON 07-25-08 CAD: ISSUE DATE: D IKERD DRAWING NUMBER: C-1490-7386578-00 NOT ISSUED FOR CONSTRUCTION SHEET NUMBER: RECEIVED JUL 2 4 2008 PERMIT CENTEF 0 r.r) 0 0 z uJ z SCALE: NO SCALE SCALE: NO SCALE ,-- VOLUME DAMPER 180 COLLAR 2 LAYERS PERF PLATE PERFORATIONS ON 3/16" STAGGERED CENTERS 22 "x48" EGGCRATE GRILLE DIFFUSER DETAIL SIDE CONNECTION N o SCALE DETAILS - HVAC 180 FLEX DUCT SQUARE BAFFLE PLATE CENTERED BELOW SUPPLY DUCT 2 LAYERS PERF PLATE 1/8"o PERFORATIONS ON 3/16" STAGGERED CENTERS 22" x48" EGGCRATE GRILLE LIGHTS --- 20" x48" EGGCRATE GRILLE NO SCALE ELEVATION AT SERVE NO SCALE CONICAL TAP •. U.w EammI. mi.i•iAmEN• 1' -10" MAIN DUCT 180 COLLAR / 3' -3 / mimmilmmlnigIMMEMIIMI •i■ i •• � • ■ •• y . u • 11•∎• morns mEMI ■ NNE MMEN E •: ::: EINE . ■......■gi _.. g 111111 . .... 11111111111111111 4. EIi , mm4iNE MO rpm ■■■. N■ NI NINNIN .•;•• u:• ■ .■■ u ■ ■ u• ■■ ■ m a r r ii ■ . MEd • ■ ■ ■■■■ ■• i•u ■∎••∎•∎i■uiu.. I ■1 ■ i■i• I u. ►N E T :••• N� •u■ ■■ =••∎∎•∎∎•=g■ 2 uu .■ • ■•• s•U•M l ■�■■ l ■ ■ ■3 ■■■ NE N on NNE mg 1U .• .■.alp.: ■..A•.■ ■■■ u ■•■• ■u•■ ••■ ■. • ■ .iiui..... .g •s E •... 3 ..•N. Mir Ell RI E M•gi ....■■■ • al U■■■• • • 1 9111111111111.1•1 0 5 VOLUME DAMPER i(LvatyvtAi ruk CODE COMPLIANCE ti PPRov . AUG - 8 6Firl CIS Of Tukwila BUILDING DIVISION _ 22" x22" BAFFLE PLATE ATTACHED TO TOP PERE DIFFUSER DETAIL - TOP CONNECTION R CO/1zr Al 2 4 2008 PERMIT CENTS MacDonald-Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206- 763 -9400 Fax: 206 - 767 -6773 www.macrniller.corn WA Lic No: NIACDOFS980RU DETAILS HVAC ENGINEER: J SHEEKS CHECKED BY: B GEZON CAD: P MILLER LAST REVISED: 07 -25 -08 DATE PLOTTED: 07 -25 -08 ISSUE DATE: DRAWING NUMBER: C 1490 - 7386578 -00 ISSUED FOR PERMIT REVISIONS: DATE DIGITAL FOREST DATA CENTER EXPANSION DC -3 DUCT LAYOUT 12101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA