Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M08-205 - DOUBLETREE SUITES
DOUBLETREE SUITES 16500 SOUTHCENTER PY M08 -205 Parcel No.: 6437300020 `Address: Suite No: Tenant: Name: Address: CO RA Tukwila 16500 SOUTHCENTER PY TUKW DOUBLETREE SUITES 16500 SOUTHCENTER PY , TUKWILA WA Owner: Name: CHA SOUTHCENTER LLC Address: 16500 SOUTHCENTER PKWY , SEATTLE WA Contact Person: Name: DAN MYERS Address: 911 WESTERN AV, STE 301 , SEATTLE WA Contractor: Name: WESTERN MECHANICAL SYSTEMS INC Address: 1911 SW CAMPUS DR #321 , FEDERAL WAY WA Contractor License No: WESTEMS921BG DESCRIPTION OF WORK: REPLACE (2) EXISTING CHILLERS (100 TON EACH) WITH (1) 176 TON CHILLER ON THE GROUND LEVEL. REPLACE (2) EXISTING CHILLED WATER CIRCULATION PUMPS (20 HP EACH) WITH (2) NEW 20 HP PUMPS WITH VFD. REPLACE (2) EXISTING 40 KW ELECTRIC UNIT HEATERS WITH (1) 399 MBH HYDRONIC BOILER SYSTEM. Value of Mechanical: 300,000.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic C onune rcial/Industrial doc: IMC -10/06 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT EQUIPMENT TYPE AND OUANTITY 0 0 0 0 0 1 0 0 0 0 0 0 0 0 * * continued on next page ** M08 -205 Permit Number: M08 -205 Issue Date: 10/15/2008 Permit Expires On: 04/13/2009 Phone: Phone: 206 515 -4004 Phone: 206 571 -3810 Expiration Date: 01/07/2010 Fees Collected: $3,020.00 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 1 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 10 -15 -2008 Permit Center Authorized Signature: I hereby certify that I have read and x governing this work will be complie wit The granting of this permit does not pr construction or the • -rformance of work. Signature: /Ny Print Name: doc: IMC -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us • Permit Number: M08 -205 Issue Date: 10/15/2008 Permit Expires On: 04/13/2009 Date: 1 o 1 l5 i,A ed this • ermit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. e to give authority to violate or cancel the provisions of any other state or local laws regulating authorized to sign and obtain this mechanical permit. Date: This permit shall become n>ili nd void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M08 -205 Printed: 10 -15 -2008 - Parcel No.: 6437300020 Address: ' Suite No: Tenant: doc: Cond - 10/06 16500 SOUTHCENTER PY TUKW DOUBLETREE SUITES 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 11: ** *FIRE DEPARTMENT CONDMONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: M08 -205 ISSUED 08/12/2008 10/15/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done m conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 13: Refrigeration units or systems having a refrigerant circuit containing more than 220 pounds of Group Al or 30 pounds of any other group refrigerant shall be provided with approved emergency signs, charts, and labels in accordance with the International Mechanical Code for the classification of refrigerants listed therein. 14: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. M08 -205 Printed: 10 -15 -2008 doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 15: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** M08 -205 Printed: 10 -15 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: 1�I / Date: / Print Name: doc: Cond -10/06 M08 -205 Printed: 10 -15 -2008 Tenant Name: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 help: un'ir.ci.tawilu.iru.us Name: " l'1'1ye t Company Name: r1'?Tt e— Company Name: Mailing Address: Contact Person: E -Mail Address: N/A Da fibter5 Q: Wpphcations\Fonns•Apph®tion8 On L eU -2006 - Permit Application.doc Revised: 9 -2006 bh Building Peri m f No. Pik : _Ai Par Mechanical Permit No. Plumbing/Gas Permit Public Works Permit No Project-No._ (For office use oily) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print" SITE LOCATION Site Address: /i3 (31t4r eeitfer i Ls)/ G.ii uiW ee Su; iS Property Owners Name: GMA 50017(CeA re-g i—e- Mailing Address: 6,500 �DI^• 1° ' Prkar Mailing Address: G} // ( kJers epV'l 11-v e— 't t)-fiP 30 E -Mail Address: O4 wt ® ('welt . C � Mailing Address: 2..o2- l 5 A4- t E -Mail Address: yht'ClQq . ; tkeravte, coY^'' Contractor Registration Number: Contact Person: E -Mail Address: Aeole(M & nvena_ King Co Assessor's Tax No.: b b.3 /300O2 00 2 Suite Number: riAkWi IA City Company Name: I110 4+Y X ✓1$- i Yl P.er lv1 Mailing Address:O( // W /- .�o 6t4 )•te 301 See -t+I e.)!� New Tenant: Floor: ❑ Yes D3[.. No State Day Telephone: 20 b • 31,1- Lbw Li City State State City State Day Telephone: • S(5' Fax Number: 7.D - I S ' gd'1(1 Zip CONTACT PERSON irho =do we contact when Yonr perniit pis ready to be issued Ste. -r-1-1 e_ LA i a 4� City State Zip Fax Number: 206 " 5 20 212 GENERAL CONTRACFOR INFORMATION (Contractor Information for 141eehanical (pg 4) for Plnmbmg and Gas Piping (pg 5)) - I Zip , C Contact Person: / liIi _ ! SoYC- Day Telephone: 421.. $(96 - (66 eP Fax Number: Expiration Date: ARCItITECT OF RECORD All( plans must be Wet sbunped b Architect of Record City Day Telephone: Fax Number: Zip ENGINEER OF RECORD. All plans .must be C tret stamped by Engineer of Record ge loy- Zip 400 L4- 2 n 1t Page 1 of 6 Unit ape: Qtt Unit Type: Qty Unit Type: Qtv Boiler /Compressor: Qtv Furnace<100K BTU Air Handling Unit - 10.000 CFM Fire Damper 0-3 HP /100,000 BTU Furnace -100K BTU Evaporator Cooler Diffuser 3 -15 HP 5110.000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP 1.000.001) BTU Suspended/Wall /Floor Mounted Heater Ventilation System Wood/Gas Stove 30-50 HP /I,750,000 BTU . Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System / / Incinerator - Domestic Other Mechanical Equipment Air Handling Unit 10.000 CFM Incinerator — Comm/Ind MECHANICAL PERMIT, INFORMATION — 206 -431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: Contact Person: kAgc(erh Me'Ct4 4%i GQ.I (S'C& W CAte4 ►, - 1-1 Motif P Je ($ E -Mail Address: Mp (V(sn . corn Contractor Registration Number: Valuation of Mechanical work (contractor's bid price): $ St tau • 9 Scope of Work (please provide detailed information): FeflAce -two e/Ct4tivi2 o k ti, — a/Q 4P 1 l . 6✓) 20 LAvlif 'P5 w i 14^ owe 4o Use: Residential: Fuel Type: Electric New . Commercial: New .... ❑ Replacement . Indicate type of mechanical work being installed and the quantity below: Q: Wpplications\Forms- Applications On LmeU -2006 - Permit Apphcation.doc Revised: 9 -2006 bh Z,&kc klaers ((op toy' e.t L4) c-0'1 +IA aeplace - fwd e) iS* &i Ckll(• 34')) ifetforijc boiler 4yfeteeti Replacement .... ❑ Q1 OA City State Zip Day Telephone: Z" 3 4 Fax Number: L Expiration Date: • on e OC L -for. c i^:(Ier- e Ike; cry rP,44^1)5 ✓ - ec, ?c ❑ Gas .... [ Other: Page 4 of 6 Fixture :Ty a :. :. T Qty ..Fixture F Type: Qi< F xture,T� ne Qri • F>itut+e Type: Qty. Bathtub or combination bath shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets j Bidet Food -waste grinder. commercial Receptor. indirect waste Clothes washer. domestic Floor drain Sinks Dental unit. cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and or vent Additional medical gas inlets outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent. except for kitchen type grease interceptors Repair or alteration of water piping and•or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas [iLUMEING AND GAS PIPING PERMIT INFORMATION - 206-431-3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Qtrrie AS MedAwn:c G ij-nac(t( Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: Valuation of Plumbing work (contractor's bid price): $ Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): Q:\Applications\Fonne- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh N /A 2)5 p0 r• tool tar ,kvcpv K a - axist;n1- He-k ir4 wow. C4 JAI Building Use (per Intl Building Code): Rte Occupancy (per Int'l Building Code): Grrvil IC- Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: City state Zip Day Telephone: Fax Number: Expiration Date: Plena Page 5 of 6 PE IT APPLICATION NOTES - AFpticable to WI permits i t us;appl catlas Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OR AU HORIZED AGENT: Signature: Date: cf / / /0, Print Name: I2.I t J71 Mailing Address: ' 1/ Al i-ft° 30 1 Q: WpphcstionsWotms- Appli atioms On Lme13 -2006 - Permit Apphcaaomdme Revised: 9 -2006 bh Day Telephone: sadifle Cit Loh 9�io S tate Zip I Date Application Accepted: 0 i 't -1p Date Application Expires: 1 Staff Initials: Page 6 of 6 Parcel No.: 6437300020 Permit Number: M08 -205 Address: 16500 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 08/12/2008 Applicant: DOUBLETREE SUITES Issue Date: Receipt No.: R08 - 02914 Initials: JEM User ID: 1165 City of Tukwila Payee: INVENTRIX ENGINEERING, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1989 3,020.00 ACCOUNT ITEM LIST: Description Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.citukwila.wa.us RECEIPT Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.0 PLAN CHECK - NONRES 000/345.830 Payment Amount: $3,020.00 Payment Date: 08/12/2008 03:21 PM Balance: $0.00 2,416.00 604.00 Total: $3,020.00 6016 08/12 9710 TOTAL 3020.00 doc: Receiot -06 Printed: 08-12 -2008 Pro'ect: e .�6 /.- -e' Sz #' S Type of In,_,pection: A- „......0. / Address: /c 5 A e'V , /b, ) Date Called: Special Instructions: e30 '......, Date Wanted: 4/-49 0 Ingo Requester: Phone No: 9.e6 - S 75" -522 v mde5 -.2o5 INSPECTION RECORD Retain a copy with permit INSPECTION NO. • NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3f 70 Approved per applicable codes. COMMENTS:a /1, _ „v _ 40,04trcc" . s Inspectdr: A Date: / REINSPECTION FEE F QUIRED! to inspection, fee must be at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Re - pt No.: !Date: Corrections required prior to approval. � N COMMENTS: P __ 0 P`rd\M d-,. c.uv / e eC , Addr 0 0 S I 1 Lo , .2) rt k —t.)9 4/J 9eCaIIed: 3 ZL N' 1 , t 1CS- e n,itN Special Instructions: '` ttt P o t O l` '# e l / "-C 5 1?l av l CX, Inc Je mx/ S (p2 o c . Phone No: ......, e t: Typ ..oflInsp li Addr 0 0 S I 1 Lo , �( c � 9eCaIIed: Special Instructions: a Wan CR. Requester: Phone No: PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. INSPECTION NO. ctor: tit. Rec - pt No.: INSPECTION RECORD Retain a copy with permit vV e0 -Corrections required prior to approval. D r f0.00 REINSP CTIO FEE RE UIRED. Prior to inspection, fee must be ' iid at 6300 Southcenter Blvd., uite 100. Call to schedule reinspection. 1Date: Project: Do v -e re. L VeS Type of Inspection: v M ee_ f'`. F Address: , Suite # #: � S u� S i„,_ L ( .7 _t Person: ke t 6-, c, in g ►,... Special Instructions: f Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: ..Occupancy Type: INSPECTION NUMBER 'I Approved per applicable codes. NSP ECTION: RECORD Retain a copy: with permit CITY OF TUKWILA:FIRE DEPARTMENT 444 Andover Park East, Tukwila,.Wa. 98188 206- 575 -4407 44 051- ao� PERMIT NUMBERS Corrections required prior to approval. COMMENTS: M er-t, oz-‹ Inspector: Date: 7_ Hrs.: / $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 06 -03 -2009 DAN MYERS 911 WESTERN AV, STE 301 SEATTLE WA 98104 RE: Permit No. M08 -205 16500 SOUTHCENTER PY TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 07/01/2009 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, - 1> oLQ Bill Rambo Permit Technician xc: Permit File No. M08 -205 Cij' of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 TNVENTRI ENGINEERING Al, Please see our responses to your review comments. End of Memo September 9, 2008 care ct,F Tomtit SEP 10 2008 To: Al Metzler From: Dan Myers Project: Double Tree Hotel Chiller Replacement Project Number: 819 (Feat # M4 -2°r) Re: Reponses to Fire Department Review Comments Copy To: File Comments: 1. Provide the quantities of R134a refrigerant (in lbs.) for each refrigerant circuit. 2. Is the area where chiller is located an outdoor or indoor area? Area is not labeled on plans. Please clarify. Responses: 1. The new chillers is a packaged equipment which contains the refrigerant within itself. Piping shown on the plans are chilled water piping. The amount of refrigerant R134a is 9501bs. 2. The chiller is located outside of the building, where the entire area is fully fenced. CORRECTION LTR# 911 Western Ave., Suite 301, Seattle, WA 98104 • P: 206.515.4004 • F: 206.515.2026 • www.inveng.com 4 4 August 28, 2008 Dan Myers 911 Western Avenue, Suite 301 Seattle, WA 98104 RE: CORRECTION LETTER #1 Mechanical Application Number M08 -205 Doubletree Suites —16500 Southcenter Py Dear Mr. Myers: This letter is to inform you of corrections that must be addressed before your plumbing permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Fire Department. At this time the Building Department has no comments. Fire Department: Al Metzler at 206 575 -4404 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not he accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Encl Brenda Holt Permit Coordinator xc: File No. M08 -205 • City of Tukwila Department of Community Development Jack Pace, Director P:\Pennit Center \Correction Letters\2008\M08 -205 Correction Ltr # 1.DOC wer • Jim Haggerton, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 a Fax: 206 - 431 -3665 Project Name: Doubletree Suites 16500 Southcenter Py Permit File No.: M08 -205 Date: August 28, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575 -4407 FIRE DEPARTMENT REVIEW COMMENTS 1. Provide the quantities of R134a refrigerant (in lbs.) for each refrigerant circuit. 2. Is the area where chiller is located an outdoor or indoor area? Area is not labeled on plans. Please clarify. ACTIVITY NUMBER: M08 -205 DATE: 09 -10 -08 PROJECT NAME: DOUBLETREE SUITES SITE ADDRESS: 16500 SOUTHCENTER PY Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: Building Division Public Works n n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROU NG: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28-02 •PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP 5t1 tuv 6 — k " In Fire Prevention Structural Incomplete n Permit Coordinator n DUE DATE: 09-11-08 Not Applicable E DATE: DUE DATE: 10-09-08 Approved n Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Planning Division n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: M08 - 205 DATE: 08 - - PROJECT NAME: DOUBLETREE SUITES SITE ADDRESS: 16500 SOUTHCENTER PY X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: � � r � 1Vt'" ni Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 7" Incomplete n Comments: Permit Center' Use Only ' INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documentslrouting slip.doc 2 -28 -02 PLAN REVIEW /ROUTING SLIP n • PERMIT COORD COPI• /1l d'wec / 4-o Fire Prevention Structural Planning Division ❑ Permit Coordinator DUE DATE: 08-14-08 Not Applicable ❑ No further Review Required DATE: n DUE DATE: 09-11 -08 Approved n Approved with Conditions n Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only' CORRECTION LETTER MAILED: Departments issued corrections: Ping ❑ PW ❑ Staff Initials: • Ag . Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 1 (ai ( Plan Check/Permit Number: M08-205 ❑ Response to Incomplete Letter # • Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: DOUBLETREE SUITES Project Address: 16500 Southcenter Py Contact Person: Dan Myers City of Tukwila \applications \forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.atulcwila.wa.us Phone Number: WV p� rinviu SEP10 MN PERMIT CENTEn ZO -fl - 'faf- Summary of Revision: PreAfae- ZG DellfA ieeQ frm; -t rev1> c .n rasporse he . Sheet Number(s): N �� "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: in Permits Plus on Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 WESTERN SURETY CO 70423303 12/11/2007 Until Cancelled $6,000.00 01/07/2008 Name Role Effective Date Expiration Date KACSO, OTTO PRESIDENT 01/07/2008 Amount KACSO, TRACI VICE PRESIDENT 01/07/2008 Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date CATLIN Untitled Page General /Specialty Contractor A business registered as a construction contractor with Lftl to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County WESTERN MECHANICAL SYSTEMS INC 2065713810 1911 SW CAMPUS DR #321 FEDERAL WAY WA 98023 KING Business Type CORPORATION Parent Company UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 602783205 ACTIVE WESTEMS921 BG CONSTRUCTION CONTRACTOR 1/7/2008 1/7/2010 KDMECI*OO8CJ PATRIGI927BN PLUMBING UNUSED Business Owner Information Bond Information Insurance Information • • Page 1 of 2 hops: // fortress. wa. gov /lni/bbip/Detail.aspx ?License= WESTEMS921 BG 10/15/2008 327,74' L 600.03' DOUBLE TREE HOTEL 502.3' SOUTHCENTER PARKWAY 561,0' PROJECT INFORMATION ADDRESS: 16500 SOUTHCENTER PARKWAY, TUKWILA WA 98188 PARCEL NUMBER: 6437300020 OWNER: DOUBLE TREE HOTEL PROJECT MANAGER: TRANE (MICHAEL JOYCE) CONTACT: 425 - 586 -1668 EMAIL: MICHAEL.JOYCE ©TRANE.COM MECHANICAL ENGINEER: INVENTRIX ENGINEERING (DAN MYERS) CONTACT: 206-515-4004 EMAIL: DANIELM©INVENG.COM PROJECT DESCRIPTION: 1. SCOPE OF ARCHITECTURAL WORK: NONE(NO BUILDING MODIFICATIONS) 2. SCOPE OF STRUCTURAL WORK: NONE(NO STRUCTURAL MODIFICATIONS) ALL NEW EQUIPMENT TO BE INSTALLED ON THE GROUND LEVEL 3. SCOPE OF CIVIL WORK: NONE(NO MODIFICATIONS TO EXISTING UNDERGROUND UTILITIES). 4. SCOPE OF MECHANICAL WORK: A. REPLACE TWO EXISTING 60 TON CHILLERS AND TWO CONSTANT SPEED CHILLED WATER CIRCULATION PUMPS WITH ONE 176 TON CENTRIFUGAL LIQUID CHILLER AND TWO VARIABLE SPEED CHILLED WATER CIRCULATION PUMPS TO IMPROVE THE EFFICIENCY OF THE CHILLER SYSTEM. B. REPLAC. TWO EXISTING 40KW ELECTRIC UNIT HEATERS WITH A HYDRONIC PREHEAT SYSTEM. THE NEW HYDRONIC PREHEAT SYSTEM CONSISiS OF ONE 399MBN GAS -FIRED BOILERS, ONE IN -LINE HEATING WATER RECIRCULATION PUMP AND ONE HEATING WATER COIL 5. REPLACE ALL EXISTING EQUIPMENT CONTROL DEVICES FOR THE ITEMS ABOVE WITH NEW DIRECT DIGITAL CONTROL SYSTEMS TO IMPROVE THE ENERGY EFFICIENCY Z Permit No. el-f- Pbr review approval Is sublact to orrcn T d onlIss?771 f,pprova# o{ construction documents doer,. not authori -ro the violation of any adopted codo or or na co Pcr 71 1 of approved Field Copy and conditions is ac'no ilc:.iNd: By .y (,e,(2 Gate: �r Tukwila 'LT RATE PE RiVip i Jc:QiUiRED FOR: C! Mechnical Air Elactrical . p as �'pin0 ukv iIa T 1 CODE RECEIVED CITY OF TUKWILA AUG 1 2 1008 PERMIT CENTER G . �vlOg- PERMIT SET J Z 111 W O W = U W Q W J a E. MI w � J m W � J o—J Dz U Date: Job No.: Drawn By: Checked by: Filename: Revisions: z z COVER SHEET G0.1 0 LCS LCO 0 C\ 08/12/08 822.00 DKM JKS SHEET 1 OF 6 LEGENDS GENERAL LINEWEIGHT LEGEND EXISTING TO REMAIN NEW WORK DEMOLITION FUTURE WORK GENERAL PLUMBING /PIPING LEGEND - -- - - DIRECTION OF FLOW FIRE PROTECTION LEGEND F DSP FDC FUEL LEGEND FOS FOR GF DF LP FV HYDRONICS LEGEND CWS CWR PCWS PCWR SCWS SCWR TCWS TCWR HWS HWR PHWS PHWR SHWS SHWR PC CD CDS CDR INDUSTRIAL LEGEND A ACT TM ARG H HE FIRE DRY STAND PIPE FIRE DEPARTMENT CONNECTION PIPE FUEL OIL SUPPLY FUEL OIL RETURN GASOLINE FUEL DIESEL FUEL PROPANE FUEL VENT CHILLED WATER SUPPLY CHILLED WATER RETURN PRIMARY CHILLED WATER SUPPLY PRIMARY CHILLED WATER RETURN SECONDARY CHILLED WATER SUPPLY SECONDARY CHILLED WATER RETURN TERTIARY CHILLED WATER SUPPLY TERTIARY CHILLED WATER RETURN HEATING WATER SUPPLY HEATING WATER RETURN PRIMARY HEATING WATER SUPPLY PRIMARY HEATING WATER RETURN SECONDARY HEATING WATER SUPPLY SECONDARY HEATING WATER RETURN PUMPED CONDENSATE CONDENSATE DRAIN CONDENSER WATER SUPPLY CONDENSER WATER RETURN AIR ACETYLN TRI -MIX ARGON HYDROGEN HELIUM LAB /MEDICAL LEGEND DW DI MA 02 CO2 N2 N20 VAC RO PLUMBING LEGEND IW ODL RDL SD SAN G SCW SHW DW ('F) LSP GW AR AR - -- KCWS KCWR REFRIGERANT LEGEND RS RR STEAM LEGEND HPS HPC MPS MPC LPS LPC STM DISTILLED WATER DEIONIZED WATER MEDICAL AIR OXYGEN CARBON DIOXIDE NITROGEN NITROUS OXIDE VACUUM REVERSE OSMOSIS DOMESTIC COLD WATER DOMESTIC HOT WATER DOMESTIC RECIRCULATED WATER VENT (ABOVE FLOOR) VENT (BELOW FLOOR) WASTE (ABOVE FLOOR) WASTE (BELOW FLOOR) INDIRECT WASTE (ABOVE FLOOR) OVERFLOW DRAIN LINE ROOF DRAIN LINE STORM DRAIN SANITARY SEWER NATURAL GAS (7" WC, UNLESS OTHERWISE NOTED) SOFT COLD WATER SOFT HOT WATER DEIONIZED WATER TEMPERED WATER AT T SHOWN LANDSCAPE SPRINKLER SUPPLY GREASE WASTE ACID RESISTANT WASTE ACID RESISTANT VENT KITCHEN CHILLED WATER SUPPLY KITCHEN CHILLED WATER RETURN REFRIGERANT PIPING SUPPLY REFRIGERANT PIPING RETURN HIGH PRESSURE STEAM HIGH PRESSURE STEAM CONDENSATE MEDIUM PRESSURE STEAM MEDIUM PRESSURE STEAM CONDENSATE LOW PRESSURE STEAM LOW PRESSURE STEAM CONDENSATE STEAM NOTE: SYMBOLS AND ABBREVIATIONS ON THE DRAWINGS SHALL BE INTERPRETED IN ACCORDANCE WITH THE LEGENDS WHEREVER APPLICABLE. NOT ALL SYMBOLS AND ABBREVIATIONS IN THE LEGENDS ARE NECESSARILY USED FOR THE PROJECT. ABBREVIATIONS GENERAL ABBREVIATIONS AFF AFG CI CFM CIRC CLG CP DIV DWG FPM FT GA IN MAX MFR MIN MNT NC GENERAL PLUMBING /PIPING ABBREVIATIONS CO CLEAN -OUT COIW COTE COTG FPWH GPM GTV ABOVE FINISH FLOOR ABOVE FINISH GRADE CAST IRON CUBIC FEET PER MINUTE CIRCULATION CEILING CHROME PLATED DIVISION DRAWING FEET PER MINUTE FEET GAUGE INCHES MAXIMUM MANUFACTURER MINIMUM MOUNT(ED) NORMALLY CLOSED CLEAN -OUT IN WALL CLEAN -OUT TO FLOOR CLEAN -OUT TO GRADE FREEZE PROOF WALL HYDRANT GALLONS PER MINUTE GAS TANK VENT GENERAL HVAC ABBREVIATIONS EXH EXHAUST AIR RA RETURN AIR ANNOTATIONS HYDRONICS ANNOTATION B -# BOILER NUMBER (BLR =1) PLUMBING ANNOTATION PLUMBING FIXTURE ITEM NUMBER P1) # "FD -# FLOOR DRAIN SIZE AND TYPE (2 "FD -1) REFRIGERANT ANNOTATION CU -# CONDENSER UNIT NUMBER (CU-1) STEAM ANNOTATION B -# BOILER NUMBER (BLR -1) HVAC ANNOTATION AH -# AIR HANDLING UNIT NUMBER (AH -1) AT -# ATTENUATOR NUMBER (AT -1) EF -# EXHAUST FAN NUMBER (EF -1) FH -# FUME HOOD NUMBER (FH -1) HR -# HEAT RECOVERY UNIT NUMBER (HR -1) L -# LOUVER NUMBER (L -1) SYMBOLS - CONT. HVAC SYMBOLS INTERNAL INSULATION aankvw/' FLEXIBLE DUCT FLEXIBLE CONNECTION UP DUCT OFFSET & DIRECTION (OR DOWN) ALUMINUM /STAINLESS STEEL DUCTWORK (AS SPECIFIED) TURNING VANES AIR SPLIT TAKEOFF VOLUME DAMPER STEAM SYMBOLS --LEI- TRAP SET (AS SPECIFIED) # INDICATES TRAP TYPE NO NORMALLY OPEN OBVD OPPOSED BLADE VOLUME DAMPER OSA OUTSIDE AIR PSI POUNDS PER SQUARE INCH PSF POUNDS PER SQUARE FOOT SP STATIC PRESSURE SS STAINLESS STEEL TYP TYPICAL VEL VELOCITY W/ WITH W /IN WITHIN W/0 WITHOUT WC WATER COLUMN 0 DIAMETER ro FLAT OVAL (E) EXISTING IE IW PRV RPBP REDUCED PRESSURE BACKFLOW PREVENTER SV SUMP VENT VTR VENT THRU ROOF SA ET -# EXPANSION TANK NUMBER (ET -1) # "FS -# FLOOR SINK SIZE AND TYPE (2 "FS -1) # "RD -# ROOF DRAIN SIZE AND TYPE (2 "RD -1) RC -# RF -# SF -# TU -# UH -# 1= 12 "x8" 24 "x18 "O cT-)/ Ei] INVERT ELEVATION INDIRECT WASTE PRESSURE REDUCING VALVE SUPPLY AIR ROOF COWL NUMBER (RC -1) RETURN FAN NUMBER (RF -1) SUPPLY FAN NUMBER (SF -1) AIR TERMINAL UNIT (TU -1) UNIT HEATER NUMBER (UH -1) SIDEWALL DIFFUSER LOUVER RECT. DUCT SIZE (WIDTHxDEPTH) CIRCULAR DUCT DIAMETER OVAL DUCT SIZE (WIDTHxDEPTH) DAMPER MOTOR OPERATOR DUCT SECURITY GRILLE FIRE, SMOKE OR FIRE /SMOKE DAMPER SYMBOLS GENERAL SYMBOLS C KEY NOTE GENERAL PLUMBING /PIPING SYMBOLS w ELBOW UP b ELBOW DOWN �+ TEE UP TEE DOWN b CONCENTRIC REDUCER /INCREASER ECCENTRIC REDUCER /INCREASER i i UNION RISE /DROP IN PIPE PIPE SLEEVE EXPANSION JOINT FLEXIBLE CONNECTION PIPE ANCHOR PIPE GUIDE CAP DETAIL NUMBER DETAIL REFERENCE �'' -SHEET NUMBER —THIS SHEET # MATCH LINE REFERENCE -- -- MATCHED SHEET # FIRE PROTECTION SYMBOLS cC FIRE DEPARTMENT CONNECTION (PEDESTAL) 4 FIRE HYDRANT 1)L1 POST INDICATOR VALVE 0441 FIRE HOSE RACK chi FIRE HOSE CABINET HYDRONICS SYMBOLS PLUMBING SYMBOLS HVAC SYMBOLS N THERMOMETER FLOOR /WALL PENETRATION FLOW SWITCH AUTOMATIC BALL DRIP THRUST RESTRAINT STRAINER PRESSURE SWITCH TWO -WAY CONTROL VAVLE THREE -WAY MODULATING CONTROL VALVE GAS VALVE ROOF DRAIN CLEAN -OUT (BELOW) CLEAN -OUT (FLUSH TO FLOOR OR GRADE) MANHOLE /DRYWELL FLOOR DRAIN NEW DUCTWORK EXISTING DUCTWORK DUCTWORK TO BE REMOVED RECT. SUPPLY DUCT (SECTION) RECT. RETURN DUCT (SECTION) RECT. EXHAUST DUCT (SECTION) ROUND SUPPLY DUCT (SECTION) ROUND RETURN DUCT (SECTION) ROUND EXHAUST DUCT (SECTION) sr CONNECTION TO EXISTING ( #" INDICATES EXISTING SIZE) _—SECTION NUMBER SECTION REFERENCE ~ -SHEET NUMBER CIRCULATING PUMP (POINTS IN DIRECTION OF FLOW) PRESSURE GAUGE D 1 VALVE (AS INDICATED OR SPECIFIED) BALL VALVE GLOBE VALVE VALVE IN RISER ANGLE VALVE CHECK VALVE PRESSURE & TEMPERATURE RELIEF VALVE PRESSURE REDUCING VALVE (POINTS TOWARDS LOW PRESSURE) SOLENOID VALVE VALVE W/TAMPER SWITCH HOSE BIBB /WALL HYDRANT HOSE BIBB (ELEVATION) CIRCUIT SETTER SERRATED COCK SPRINKLER HEAD (UPRIGHT) SPRINKLER HEAD (PENDANT) SPRINKLER HEAD (WET SIDE WALL) SPRINKLER HEAD (DRY SIDE WALL) GAUGE COCK SIGHT GLASS AUTOMATIC AIR VENT MANUAL AIR VENT VENTURI AIR SEPARATOR CONDENSATE TRAP FLOOR SINK WATER HAMMER ARRESTER VENT THRU ROOF DOWNSPOUT NOZZLE SANITARY CROSS SANITARY TEE WYE 0 THERMOSTAT /7 --__DIFFUSER SIZE DIFFUSER TYPE 10x10 -2 DIFFUSER OR REGISTER /GRILLE 250 INFORMATION CFM VALUE RECTANGULAR DIFFUSER ® RECTANGULAR REGISTER /GRILLE LINEAR DIFFUSER CIRCULAR DIFFUSER ,E COMPLIANCE APPR AYE SEP 1. 8 2Q88 Ut/ Of TukWlia EVISIOR RECEIVE CITY OF TUKWILA AUG 12100$ PERMIT CENTER PERMIT SET z z J Z W W O W = U W Q W I a � w W J Q' CO W M O 1-1 D Z U Date: Job No.: Drawn By: Checked by: Filename: Revisions: cD P Q OD cm Q )1 LCD erD OQ CD cD cD OD cD 0 UD QD C] cd 08/12/08 822.00 DKM JKS LEGENDS AND ABBREVIATIONS M/EO.i SHEET 2 OF 6 PIPING MATRIX SERVICE ID SERVICE DESCRIPTION LOCATION/ AREA OPERATING PRESSURE (PSIG) SIZE MATERIAL CONNECTION TYPE & FITTINGS SPEC REFERENCE FLANGES, , UNIONS & CPLGS CONNECTIONS MFR & MODEL ISOLATION VALVE TYPE ISOLATION VALVE RATING CHECK VALVE RATING BALANCE VALVE MFR & MODEL STRAINER MFR & MODEL PRESSURE GAUGE MFR & MODEL TEMPERATURE GAUGE MFR & MODEL TEST PROCEDURE NOTE: ISOLATE ALL EQUIPMENT PRIOR TO TESTING SEISMIC BRACING IMPORTANCE FACTOR NOTES MEDIA MINIMUM TEST PRESSURE MAXIMUM TEST PRESSURE MINIMUM DURATION CODE REFERENCE CHILLED WATER CHILLED WATER SUPPLY & RETURN ALL 12 2" AND SMALLER COPPER TUBE TYPE L CARBON�TEEL PIPE A53B ERW STANDARD WEIGHT 95 -5 SOLDER (CU) THREADED (STEEL) SEC 230901 C x C UNION (CU) Elkhart WROT 102 M.I. UNION (STEEL) Anvil Fig. 463 Class 150 300 psi WOG UNISOURCE UPCB (CU) UNISOURCE UPCS (STEEL) BALL 600 WOG @ 250 deg F (Milwaukee BA -350 or similar) solder, 200 psi WOG (Milwaukee 1509 or similar) Nibco 51710 or Gruvlok GBV -S MUELLER 351M 200 psi WOG Winters Model LF /Q700 Winters Model 91T WATER 150% OF OPERATING PRESSURE, NOT LESS THAN 100 PSIG MAX. ALLOWABLE TEST PRESSURE ANY COMPONENT OR 90% OF YIELD VOT LESS THAN 15 MINUTES, LOWER TO OPERATING PRESSURE FOR 24 HOURS AND PERFORM, VISUAL INSPECTION WITH NO LEAKS 2003 IMC, SECTION 1208 1.0 54 2 -1/2" AND LARGER CARBON STEEL PIPE A53B ERW STANDARD WEIGHT BUTTWELD OR GROOVED 150# WELD NECK FLANGE GROOVED FLANGE OR COUPLING UNISOURCE UPCS -FLG GRUVLOK SV21 BUTTERFLY 200 p si g, lu bod (Milwaukee ML223B or similar) 200 psi WOG, Flanged, Horizontal use only Gruvlok 7800 Series, 300 psig WOG (Milwaukee F- 2874 -M or similar) Gruvlok GBV -G Dezurik PEC plug valves, cast iron, 175 psig WOG for use on pump discharge) MUELLER 758 or MUELLER 165 200 psi WOG (2" to 12 ") 150 psi WOG (14" to 24 ") Gruvlok 758G HEATING HOT WATER HEATING HOT WATER SUPPLY & RETURN ALL 12 2" AND SMALLER COPPER TUBE TYPE L 95 -5 SOLDER (CU) THREADED (STEEL) SEC 230901 C x C UNION (CU) Elkhart WROT 102 M.I. UNION (STEEL) Anvil Fig. 463 Class 150 300 psi WOG UNISOURCE UPCB (CU) UNISOURCE UPCS (STEEL) BALL 600 WOG @ 250 deg F (Milwaukee BA -350 or similar) solder, 200 psi WOG (Milwaukee 1509 or similar) Nibco S1710 or Gruvlok GBV -S MUELLER 351M 200 psi WOG Winters Model LF /Q700 Winters Model 91T WATER 30% GLYCOL 150% OF OPERATING PRESSURE MAX. ALLOWABLE TEST PRESSURE ANY COMPONENT OR 90% OF YIELD VOT LESS THAN 15 MINUTES, LOWER TO OPERATING PRESSURE FOR 24 HOURS AND PERFORM A VISUAL INSPECTION WITH NO LEAKS ASME 831.9 1.0 2 -1/2" AND LARGER CARBON STEEL PIPE A53B ERW STANDARD WEIGHT BUTTWELD OR GROOVED 150# WELD NECK FLANGE, GROOVED FLANGE OR COUPLING UNISOURCE UPCS -FLG GRUVLOK SV21 BUTTERFLY 200 si lug body p g, g y (Milwaukee ML223B or similar) 200 psi WOG, Flanged, Horizontal use only Gruvlok 7800 Series, 300 psig WOG (Milwaukee F- 2974 -M or similar) Gruvlok GBV -G Dezurik PEC plug valves, cast iron, 175 psig WOG (for use on pump discharge) MUELLER 758 or MUELLER 165 200 sj WOG p (2" to 12 ") 150 psi WOG (14" to 24 ") Gruvlok 758G NOTES: GAS FIRED BOILERS B -# MFR MODEL # TYPE CAPACITY (MBH) EFF ( % ) MIN GAS PRESSURE ( WC) HEATING WATER ELECTRICAL COMB. AIR INTAKE PIPE DIA. ( ") EXHAUST FLUE DIA. ( ) SHIPPING WEIGHT (LBS) DIMENSIONS (W "XH "XL ") NOTES INPUT OUTPUT L WT ( °F) EWT ( °F) FLOW (GPM) V /PH /HZ MAX AMP DRAW 1 HAMILTON EVO DUO 399 CONDENSING BOILER 399.9 379.9 95 4 180 150 25.4 208/1/60 3.15 4 4 194 25X32X27 1,2,3,4 NOTES: 1. BOILER OUTPUT AND FLOW IS SIZED FOR 75% OF THE DESIGN CAPACITY. 2. PROVIDE WITH BOILER CONTROL PANEL WITH MODULATING BOILER BURNER CONTROL AND BOILER SEQUENCING PANEL. 3. PROVIDE WITH PVC EXHAUST VENT AND COMBUSTION AIR INTAKE PIPE ASSEMBLIES . 4. PROVIDE WITH REMOTE EMERGENCY SHUTDOWN SWITCHES. AIR COOLED CHILLERS CH - # MFR MODEL COP REFRIGERANTS NOMINAL CAPACITY (TONS) DESIGN PRESSURE (PSI) WATER FLOW (GPM) W EVAPORATOR DATA ELECTRICAL APPROX. WEIGHT (LBS) NOTES ET ( °F) W LT ( °F) # CIRCUITS FOULING FACTOR PRESSURE DROP (PSI) V /PH RLA MCA MAX FUSE 1 SMARDT A0610- 2K -5FV 2.88 R134A 176 190 422 54 44 3 0.0001 6.9 460/3 301 350 450 10180 2 SMARDT A0610- 2K -5FV 2.88 R134A 176 190 422 54 44 3 0.0001 6.9 460/3 301 350 450 10180 1750 NOTES: HVAC PUMPS PIPING SYSTEM P- # MFG MODEL # TYPE SERVICE FLOW (GPM) HEAD (') BHP EFF ( %) SUCTION SIZE ( ") DISCH SIZE ( ") MOTOR NOTES RPM HP V/0 1 BELL & GOSSETT 3G- SERIES 1510 BASE- MOUNTED CHILLED WATER 360 125 0.5 73 4 3 1750 20 460/3 1, 2 2 BELL & GOSSETT 3G- SERIES 1510 BASE - MOUNTED CHILLED WATER 360 125 73 4 3 1750 20 460/3 1, 2 3 BELL & GOSSETT 90- 1 -1/2A IN -LINE HEATING WATER 25.4 30 0.42 47.2 1.5 1.5 1750 0.75 120/1 NOTES 1. PROVIDE WITH INLET SUCTION DIFFUSER AND DISCHARGE TRIPLE DUTY VALVE. 2. MOTOR SHALL BE VFD RATED. PIPE & EQUIPMENT INSULATION SCHEDULE PIPING SYSTEM TEMP RANGE THERMAL COND MEAN RAT TEMP INSULATION MATERIAL INSULATION THICKNESS BY PIPE SIZE NOTES RUNOUTS TO 2" 1" AND LESS GREATER THAN 1" HEATING HOT WATER <200 0.24 -0.28 180 FIBERGLASS 0.5 1.5 1.5 1 CHILLED WATER 40 -55 0.24 -0.28 45 FIBERGLASS 0.5 0.5 1 1 NOTES: 1. RUNOUTS TO INDIVIDUAL TERMINALS NOT TO EXCEED 12 FEET IN LENGTH ENERGY CODE NOTES 1 SECTION 1411.1: ALL EQUIPMENT SHALL MEET THE MINIMUM EFFICIENCY REUIREMENTS LISTED ON TABLE 14 -1A THROUGH 14 -1G. SEE SCHEDULE FOR EQUIPMENT EFFICIENCIES. 3 SECTION 1416: PERFORM COMMISSIONING, TESTING AND BALANCING IN ACCORDANCE WITH WA STATE ENERGY CODE SECTION 14.16. � a � t .� 7 SECTION 1422: THERMOSTATS SHALL BE INTERLOCKED TO PREVENT SIMULTANWOUS HEATING AND COOLING. ig N:tf , �. e RECEIVED CITY OF TUKWILA AUG 121008 PERMIT CENTER PERMIT SET Revisions: 1-• J Z W W O W = U W Q W J 1.- w � -I IX OLLJ M o-J ci : 0 M0.2 k Date: 08/12/08 Job No.: 822.00 Drawn By: DKM Checked by: JKS Filename: SCHEDULES - MECHANICAL SHEET 3 OF 6 I; .1 SITE PLAN - MECHANICAL M1.0 = 0 cio.5 5ma , • 4 l_ r ,, PROVIDE PRESSURE REGULATOR CAPABLE OF IMAINTAINING 7" TO 11" WC OUTLET PRESSURE. WORK AREA. SEE ■■• MENEM 102 WORK AREA. SEE 1'5 '1 WORK AREA. SEE EXISTING GAS METER EXISTING GAS MAIN ROUTE 1-1/4" 0 FROM EXISTING GAS MAIN DOWN STREAM OF METER TO MECH ROOM 141. NEW GAS PIPING SHALL BE INSTALLED APPROXIMATELY 9`-0" AFF, AND ATTACHED SECURELY TO EXTERIOR WALL BY PIPE HANGERS OR CLAMPS. „-- GAS PIPING ON ROOF 1-1/4"DN. SEE M3.1 FOR CONTINUATION GENERAL NOTES: 1. EXISTING BUILDING LAYOUT SHOWN IS DIAGRAMMATIC AND MAY NOT BE ACCURATE. CONTRACTOR SHALL FIELD VERIFY EXISTING BUILDING LAYOUT PRIOR TO PERFORMING ANY WORK. RECEIVED CITY OF TUKVVILA AUlj 1 2 Z008 PERMIT CENTER PERMIT SET Date: Job No.: Drawn By: Checked by: Filename: Revisions: (.1 (r) SITE PLAN MECHANICAL & ELECTIRCAL M/E1.0 08/12/08 822.00 DKM JKS SHEET 4 OF 6 (E)PANEL - W TO REMAIN DEMO PLAN — MECH ROOM 141 F 1/4' = 1 -Q. DEMO PLAN — CHEF'S OFFICE i 1/4' = 1' -0` GENERAL NOTES: 1. EXISTING BUILDING AND MECHANICAL EQUIPMENT LAYOUTS SHOWN ARE DIAGRATIC AND MAY NOT BE ACCURATE. CONTRACTOR SHALL FIELD VERIFY EXISTING BUILDIGN AND EQUIPMENT CONDITIONS PRIOR TO PERFORMING ANY WORK. KEY NOTES: clJ EXISTING 40KW UNIT HEATERS AND ASSOCIATED CONTROL DEVICES TO REMAIN. DEMO EXISITNG LINE VOLTAGE WIRING FROM UNIT HEATER TO ASSOCIATED PANEL. I 1 , 1 1 1 1 1 1 1 I 1 1 , 1 1 1 1 1 1 1, 1, r' L 1 � I � I (1 1 I 1 1 1 1 1 1 1 I 1 1 1 1 1 1 1 1 1 1 1 1 1 I 1 1 1 1 1 1 1 11 1 DEMO PLAN — MECH ROOM 133 E = 1' -0' 0 J L GENERAL NOTES: 1. EXISTING BUILDING AND MECHANICAL EQUIPMENT LAYOUTS SHOWN ARE DIAGRATIC AND MAY NOT BE ACCURATE. CONTRACTOR SHALL FIELD VERIFY EXISTING BUILDIGN AND EQUIPMENT CONDITIONS PRIOR TO PERFORMING ANY WORK. 2. KEY NOTES: DEMO EXISTING CHILLER AND ASSOCIATED CONTROL DEVICES. MAINTAIN EXISTING CHILLER AND CONNECTED PIPING IN OPERATION UNTIL NEW CHILLER IS INSTALLED, TESTED AND READY TO BE CONNECTED TO EXISTING CWS AND CWR PIPING. ONCE NEW CHILLER AND CHILLED WATER PIPING IS COMPLETELY INSTALLED, DEMO EXISTING CHILLER AND ASSOCIATED CONTROL DEVICES. 0 DEMO EXISTING CHILLED WATER PUMP AND BRANCH PIPING AS TO ALLOW INSTALLATION OF NEW PUMPS AND PIPING ACCESSORIES. DISCONNECT POWER FEED TO PUMP PRIOR TO DEMOLITION OF PUMP. EXISTING JUNCTION BOX TO REMAIN. REMOVE POWER FEED TO EXISTING CHILLER. REMOVE EXISTING 400A CHILLER DISCONNECT SWITCH. EXISTING 400A CHILLER DISCONNECT TO REMAIN. DEMO EXISTING CHILLED WATER SUPPLY AND RETURN PIPING UP TO WALL PENETRATIONS. EXISTING WATER HEATER TO REMAIN. DEMO EXISTING CHILLED WATER SUPPLY AND RETURN RISERS. DEMO EXISTING CHILLED WATER SUPPLY AND RETURN PIPING. C B zaaa RECEIVED CITY OF TUKWILA AUU 1 21008 PERMIT CENTER PERMIT SET r Revisions: z z 1 = " 4: lc z e rn v c cn o Q a E c DEMO PLAN - MECHANICAL & ELECTRICAL M /E2.1 Date: 08/12/08 Job No.: 822.00 Drawn By: DKM Checked by: JKS Filename: SHEET 5 OF 6 '1 ` I I, ' 1 \ I\ 1 f , 1\ ; 0 i (E)PANEL - W TO REMAIN DEMO PLAN — MECH ROOM 141 F 1/4' = 1 -Q. DEMO PLAN — CHEF'S OFFICE i 1/4' = 1' -0` GENERAL NOTES: 1. EXISTING BUILDING AND MECHANICAL EQUIPMENT LAYOUTS SHOWN ARE DIAGRATIC AND MAY NOT BE ACCURATE. CONTRACTOR SHALL FIELD VERIFY EXISTING BUILDIGN AND EQUIPMENT CONDITIONS PRIOR TO PERFORMING ANY WORK. KEY NOTES: clJ EXISTING 40KW UNIT HEATERS AND ASSOCIATED CONTROL DEVICES TO REMAIN. DEMO EXISITNG LINE VOLTAGE WIRING FROM UNIT HEATER TO ASSOCIATED PANEL. I 1 , 1 1 1 1 1 1 1 I 1 1 , 1 1 1 1 1 1 1, 1, r' L 1 � I � I (1 1 I 1 1 1 1 1 1 1 I 1 1 1 1 1 1 1 1 1 1 1 1 1 I 1 1 1 1 1 1 1 11 1 DEMO PLAN — MECH ROOM 133 E = 1' -0' 0 J L GENERAL NOTES: 1. EXISTING BUILDING AND MECHANICAL EQUIPMENT LAYOUTS SHOWN ARE DIAGRATIC AND MAY NOT BE ACCURATE. CONTRACTOR SHALL FIELD VERIFY EXISTING BUILDIGN AND EQUIPMENT CONDITIONS PRIOR TO PERFORMING ANY WORK. 2. KEY NOTES: DEMO EXISTING CHILLER AND ASSOCIATED CONTROL DEVICES. MAINTAIN EXISTING CHILLER AND CONNECTED PIPING IN OPERATION UNTIL NEW CHILLER IS INSTALLED, TESTED AND READY TO BE CONNECTED TO EXISTING CWS AND CWR PIPING. ONCE NEW CHILLER AND CHILLED WATER PIPING IS COMPLETELY INSTALLED, DEMO EXISTING CHILLER AND ASSOCIATED CONTROL DEVICES. 0 DEMO EXISTING CHILLED WATER PUMP AND BRANCH PIPING AS TO ALLOW INSTALLATION OF NEW PUMPS AND PIPING ACCESSORIES. DISCONNECT POWER FEED TO PUMP PRIOR TO DEMOLITION OF PUMP. EXISTING JUNCTION BOX TO REMAIN. REMOVE POWER FEED TO EXISTING CHILLER. REMOVE EXISTING 400A CHILLER DISCONNECT SWITCH. EXISTING 400A CHILLER DISCONNECT TO REMAIN. DEMO EXISTING CHILLED WATER SUPPLY AND RETURN PIPING UP TO WALL PENETRATIONS. EXISTING WATER HEATER TO REMAIN. DEMO EXISTING CHILLED WATER SUPPLY AND RETURN RISERS. DEMO EXISTING CHILLED WATER SUPPLY AND RETURN PIPING. C B zaaa RECEIVED CITY OF TUKWILA AUU 1 21008 PERMIT CENTER PERMIT SET r Revisions: z z 1 = " 4: lc z e rn v c cn o Q a E c DEMO PLAN - MECHANICAL & ELECTRICAL M /E2.1 Date: 08/12/08 Job No.: 822.00 Drawn By: DKM Checked by: JKS Filename: SHEET 5 OF 6 ` i 1/4" = 1' -0" HEATING WATER COIL (E)RETURN DUCT BELOW B-1 GAS SHUT -OFF VALVE FLOOR PLAN - MECH__ROOM 141 ,-1 -1/4" UP. SEE M1.0 FOR CONTINUATION 1- 1 /4 "G. ROUTE PIPE AS HIGH AS POSSIBLE. FLOOR PLAN - CHEF'S OFFICE 1/4" = r-0" GENERAL NOTES 1. INSULATE ALL PIPING IN ACCORDANCE WITH WA STATE ENERGY CODE. 2. WEATHER PROOF ALL PIPE WALL PENETRATIONS WITH MECHANICAL SLEEVES. 3. THE INTENT OF THIS PLAN IS TO PROVIDE DIAGRAMATIC MECHANICAL EQUIPMENT LAYOUTS. IT IS CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY ALL VISIBLE EXISTING CONDITIONS PRIOR TO INSTALLING NEW MECHANICAL EQUIPMENT. 4. MAINTAIN SERVICE CLEARANCES REQUIRED BY EQUIPMENT MANUFACTURERS. 5. ALL GAS PIPING SHALL BE SIZED IN ACCORDANCE WITH UPC 2006, AND BOILER MANUFACTURER'S REQUIREMENTS. KEY NOTES \!J ROUTE GAS PIPING TO BOILER GAS SUPPLY INLET. • INSTALL BOILERS ON WALL WITH UNI -STRUT RACK PER BOILER MANUFACTURER'S RECOMMENDATION. 0 ROUTE 4" PVC VENT PIPE FROM BOILER OUTLET UP THROUGH ROOF AND TERMINATE WITH ONE 90' ELBOW. PROVIDE BIRD SCREEN AT END. BOILER FLUE VENT PIPING ASSEMBLY SHALL BE PROVIDED BY BOILER MANUFACTURER AND INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. ® ROUTE 4" PVC COMBUSTION AIR INTAKE PIPE FROM BOILER CONNECTION UP THROUGH ROOF AND TERMINATE WITH TWO 90` ELBOWS(PIPE OPENING SHALL FACE DOWNWARD TO ELIMINATE WATER INTRUSION). PROVIDE BIRDSCREEN AT END. COMBUSTION AIR INTAKE PIPING ASSEMBLY SHALL BE PROVIDE BY BOILER MANUFACTURER AND INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. 0 ROUTE 2" HWS & HWR DN AND TO BOILER SUPPLY AND RETURN WATER PIPING CONNECTIONS. 0 BOILER ELECTRICAL LOAD IS 3.15AMPS. FEEDER SHALL BE 2 #12, 1#12G TYPE THHN /THWN COPPER IN 3/4" EMT CONDUIT WITH 20A DISCONNECT AT BOILER. FEED FROM PANEL - W, CIRCUIT NO. 36 & 38. 0 PUMP ELECTRICAL LOAD IS 7.6AMPS. FEEDER SHALL BE 2 #12, 1 #12G TYPE THHN /THWN COPPER IN 3/4" EMT CONDUIT WITH 20A DISCONNECT AT PUMP. FEED FROM PANEL - W, CIRCUIT NO. 40 & 42. PROVIDE 20A, 208V, 2PHASE CIRCUIT BREAKER AT PANEL. KEY NOTES O UTILIZE AVAILABLE SAPRE CIRCUITS(CKT NO. 36, 38, 40 AND 42) ON EXISTING PANEL - W FOR NEW MECHANICAL EQUIPMENT, B-1 AND IN MEHCANICAL ROOM 141. (E)JUNCTION BOX FLOOR PLAN - MECH ROOM 133 IL 113.1 1/4" = 1'--0" GENERAL NOTES 1. INSULATE ALL PIPING IN ACCORDANCE WITH WA STATE ENERGY CODE. 2. WEATHER PROOF ALL PIPE WALL PENETRATIONS WITH MECHANICAL SLEEVES. 3. THE INTENT OF THIS PLAN IS TO PROVIDE DIAGRAMATIC MECHANICAL EQUIPMENT LAYOUTS. IT IS CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY ALL VISIBLE EXISTING CONDITIONS PRIOR TO INSTALLING NEW MECHANICAL EQUIPMENT, 4. MAINTAIN SERVICE CLEARANCES REQUIRED BY EQUIPMENT MANUFACTURERS. KEY NOTES CONNECT TO EXISTING CWS MAIN. CONNECT TO EXISTING CWR MAIN. PROVIDE 4" HOUSEKEEPING PAD UNDER PUMP. RECONNECT ELECTRICAL POWER FEED TO NEW PUMP. ROUTE FEEDER THROUGH VARIABLE FREQUENCY DRIVE. ANY NEW FEEDER REQUIRED SHALL BE 4 #10, 1 #10G TYPE THHN /THWN COPPER WIRE IN 3/4" EMT CONDUIT. PROVIDE NEW 400A FEEDER FROM EXISTING JUNCTION BOX TO NEW FUSED DISCONNECT. FEEDER SHALL BE 4 #600KCMIL, 1 #2G TYPE XHHW -2 IN 4" EMT CONDUIT. FUSED DISCONNECT SHALL BE 400A. ALL CONDUIT CLOSURES SHALL BE WEATHER - TIGHT. co vy 6 t . l : t lr i t) di & C P RECEIVED CITY OF TUKVVILA NW. 1 2 1008 PERMIT CENTER PERMIT SET 1 Date: Job No.: Drawn By: Checked by: Filename: Revisions: a) 0) 0 LCD cd H FLOOR PLAN - MECHANICAL & ELECTRICAL M /E3.1 08/12/08 822.00 DKM JKS SHEET6OF6