Loading...
HomeMy WebLinkAboutPermit M08-207 - METRO COMPONENT SUPPLY AND SOUTHMETRO COMPONENT SUPPLY & SOUTH BASE 12000 EAST MARGINAL WAY S EXPIRED 08 -28 -09 M08 -207 Parcel No.: 7340600421 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: CityOf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 12000 EAST MARGINAL WY S TUKW METRO COMPONENT SUPPLY & SOUTH BASE 12000 EAST MARGINAL WAYS , TUKWILA WA KING COUNTY 500 K C ADMIN BLDG , SEATTLE WA Contact Person: Name: GERRIE JACKSON Address: 201 S JACKSON ST KSC -TR -0431 , SEATTLE WA Contractor: Name: RCNW Address: PO BOX 188 , RENTON, WA Contractor License No: RCNW *CN978L6 MECHANICAL PERMIT DESCRIPTION OF WORK: INSTALL ROOF MOUNTED COMPRESSOR, DUCT WORK AND CONTROLS Value of Mechanical: $15,790.00 Type of Fire Protection: SPRINKLERS Furnace: <100K BTU 0 >100K BTU 0 Floor Furnace 0 Suspended/Wall/Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System.... 0 Air Handling Unit <10,000 CFM 0 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 0 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial/Industrial 0 doc: IMC - 10/06 EQUIPMENT TYPE AND QUANTITY * *continued on next page ** Permit Number: M08 -207 Issue Date: 09/02/2008 Permit Expires On: 03/01/2009 Phone: Phone: 206 - 684 -1334 Phone: (425)254 -9999 Expiration Date: 06/26/2009 Fees Collected: $350.00 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment M08 -207 Printed: 09 -02 -2008 Permit Center Authorized Signature: b City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • Permit Number: M08 -207 Issue Date: 09/02/2008 Permit Expires On: 03/01/2009 Date: 9 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the ;j ormance of work. I1 am authorized to sign and obtain this mechanical permit. Q Signature: � N/ 7 . k. o - '' -- � Date: l ° - cl� Print Name: f \/ /c, cI S S N( This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -10/06 M08 -207 Printed: 09 -02 -2008 Parcel No.: 7340600421 Address: Suite No: Tenant: 12000 EAST MARGINAL WY S TUKW METRO COMPONENT SUPPLY & SOUTH BASE 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: M08 -207 ISSUED 08/15/2008 09/02/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Cond - 10/06 * *continued on next page ** M08 -207 Printed: 09 -02 -2008 Signature: ® • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Print Name: 1E \ // < cS ,4/ doc: Cond -10/06 M08 -207 Date: — ordinances governing or local laws regulating Printed: 09 -02 -2008 SITE LOCATION King Co Assessor's Tax No.: 7340600421 Site Address: 12000 East Marginal Way S Suite Number: Floor: Tenant Name: Metro Component Supply (a South RAgP New Tenant: ❑ Yes ]..No Property Owners Name: King County Metro Mailing Address: 201 South Jackson St KSG -TR- -0 431 CONTACT PERSON - who do we contact when your permit is ready to be issued Name: Mailing Address: 201 S Jackson St BSC -TB -0431 E -Mail Address: GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Nam' Mailing Address: Contact Person: E -Mail Address: Company Name: Mailing Address: Company Name: Mailing Address: CITY OF TUKUVIL.A Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.cltukwila.wa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print** Gerrie Jackson gerrie . j ackson(aki ngcnunty . gnv Road Construction Northwest, Inc 2500 East Valley Road #C3 Renton WA 98057 City Day Telephone: Fax Number: Expiration Date: Peter J. Kenney Contractor Registration Number: RCNW * C N 9 7 8 L 6 Arai Jackson Ellison Murakami LLP lim■••■••■•■■■•■ii Building Permit No. D - L( 03 Mechanical Permit No. MVO- 20 7 Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Soattle, W� 98104 Day Telephone: (206) 684-1334 Seattle, WA 98104 Zip City Fax Number: (206) 684 Zip (425) State 254 -9999 (425) 254 -1334 ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record 2300 7th Avenue Seattle WA 98121 City Contact Person: Ben Dayo t Day Telephone: (206) E- MailAddress: bdayot @araijackson.com Fax Number: (206) 323 - 8518 ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record 1 CDT F r 4200 194th Street SW Suite 200 Lynnwood WA 98036 city Contact Person: Jon Della Day Telephone: (425) 672-1071 E-Mail Address: Fax Number: Q: AppliWionz Worms.Applicatiom On Lme13 -2006 - PumitApplcation.doc Revised 9-2006 bh State Zip Page l of 6 BUILDING PERMIT INFO ION — 206 -431 -3670 Valuation of Project (contractor's bid price): $ $ 66.210 Existing Building Valuation: $ Scope of Work (please provide detailed information): Remodel and expand Chief's office Remove: existing windos and CMU; partition walls, doors & casework; suspended ceilingLtile, portions of floor tile: AC wall unit Install: metal stud walls; insulation; GWB; windows; doors and niches, new roof; ceiling tile; fire sprinklers; roof mounted compressor Will theliS - ack ?l e t t ' iva 1 E .. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard Compact Handicap: Will there be a change in use? ❑ Yes ❑ No If `yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: Ei Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8 - 1/2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department Q: WppiicNiomWams- Apptications On Line \3-2006 - ?emit Appfic tion.doc Revised 9 -2006 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1" Floor 382 197 II N B 2 2nd Floor 3`d Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFO ION — 206 -431 -3670 Valuation of Project (contractor's bid price): $ $ 66.210 Existing Building Valuation: $ Scope of Work (please provide detailed information): Remodel and expand Chief's office Remove: existing windos and CMU; partition walls, doors & casework; suspended ceilingLtile, portions of floor tile: AC wall unit Install: metal stud walls; insulation; GWB; windows; doors and niches, new roof; ceiling tile; fire sprinklers; roof mounted compressor Will theliS - ack ?l e t t ' iva 1 E .. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard Compact Handicap: Will there be a change in use? ❑ Yes ❑ No If `yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: Ei Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8 - 1/2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department Q: WppiicNiomWams- Apptications On Line \3-2006 - ?emit Appfic tion.doc Revised 9 -2006 bh Page 2 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor. Qty Fumace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Fumace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30-50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Q/ T Other Mechanical Equipment H t Pump 1 Air Handling Unit <10,000 CFM Incinerator — Comm/Ind G11 O MECHANICAL PERMIT INFORMATION - 206-431-3670 MECHANICAL CONTRACTOR INFORMATION Company Name: will be subbed out Mailing Address: cit Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number Expiration Date: Valuation of Mechanical work (contractor's bid price): $ $ 1 5, 790 (engineers estimate) Scope of Work (please provide detailed information): T n s t a l l r nn f mn t 1 n t P d n nmp r e s s n r, duct work and contt:ols Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ® Replacement .... ❑ Fuel Type: Electric 10 Gas ....0 Other: Indicate type of mechanical work being installed and the quantity below: • State zip QMpplicationeTamt- Applications Ou Linc\3 -2006 - Permit Applicetiondoc Revised: 9 -2006 bh Page4of6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE R AUTHORIZED AGENT: Signature: : �/ Z Print Name: Gerrie Jackson Date: Day Telephone: (206) 684 - 1334 MailingAddress: 201 South Jackson St. KSC -TR -0431, Seattle. WA 98104 City State zip Date Application Expires: — r —0 6 1 Date Application Accepted S t s -_ D g QWpplicationt inns-Applications On Line O-2006 - Permit Apptication.doc Revised: 9-2006 bb Staff Initials: Page 6 of 6 1 Parcel No.: 7340600421 Permit Number: M08 -207 Address: 12000 EAST MARGINAL WY S TUKW Status: APPROVED Suite No: Applied Date: 08/15/2008 Applicant: METRO COMPONENT SUPPLY & SOUTH BASE Issue Date: Receipt No.: R08 -03116 Initials: WER User ID: 1655 Payee: KING COUNTY TRANSACTION LIST: Type Method Descriptio Amount MECHANICAL - NONRES City of Tukwila ACCOUNT ITEM LIST: Description Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Payment Check 4601 280.00 RECEIPT Account Code Current Pmts 000.322.102.00.0 280.00 Total: $280.00 Payment Amount: $280.00 Payment Date: 09/02/2008 02:36 PM Balance: $0.00 63( , )9/03 1 707 TOTAL 1 6.1.5) doc: Receiot -06 Printed: 09 -02 -2008 Parcel No.: 7340600421 Permit Number: M08 -207 Address: 12000 EAST MARGINAL WY S TUKW Status: PENDING Suite No: Applied Date: 08/15/2008 Applicant: METRO COMPONENT SUPPLY & SOUTH BASE Issue Date: Receipt No.: R08 -02964 Initials: WER Payment Date: 08/15/2008 11:31 AM User ID: 1655 Balance: $280.00 Payee: KING COUNTY TRANSACTION LIST: Type Method Descriptio Amount ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us Payment Check 4590 70.00 RECEIPT Account Code Current Pmts 000/345.830 70.00 Total: $70.00 Payment Amount: $70.00 6176 08/15 7716 TOTAL 70.00 doc: Receiot -06 Printed: 08-15 -2008 GERRIE JACKSON 201 S JACKSON ST KSC -TR -0431 SEATTLE WA 98104 City qf Tukwila RE: Permit No. M08 -207 12000 EAST MARGINAL WY S TUKW Dear Permit Holder: Based on the above, you are hereby advised to: The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. -or- Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician 1› File: Permit File No. M08 -207 Jim Haggerton, Mayor Department of Community Development Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 08/28/2009. 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period. 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. In the event you do not call for an inspection and /or receive an extension prior to 08/28/2009, your permit will become null and void and any further work on the project will require a new permit and associated fees. 6300 Southcenter Boulevard. Suite #100 • Tukwila. Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 March 3, 2009 Gerrie Jackson King County Dept of Transportation 201 S Jackson St, M/S KSC -TR -0431 Seattle, WA 98104 -3856 RE: Request for Extensions Development Permit No. D08 -403 Mechanical Permit No. M08 -207 Metro Component & Supply (South Base) Dear Ms. Jackson, City of Tukwila Department of Community Development Jack Pace, Director This letter is in response to your written request for an extension to Permit Numbers D08 -403 and M08 -207. The Building Official has reviewed your letter and considered your request to extend the above referenced permits. The City of Tukwila Building Division will be extending your permits an additional 180 days from the original date of expiration, August 28, 2009. If you should have any questions, please contact our office at (206) 431 -3670. Sincerely, ifer Marshall it Technician File: Permit Nos. D08 -403 & M08 -207 P:\Permit Center\Extension Letters\Pemiits\2008\D08 -403 Permit Extension.doc jem Jim Haggerton, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 King County Department of Transportation Transit Division Design & Construction Section 201 South Jackson Street, M/S KSC -TR -0431 Seattle, WA 98104 -3856 Fax: (206) 684 -1900 February 26, 2009 Mr. Bob Benedicto Building Official City of Tukwila 6300 Southcenter Boulevard, Suite 100 Tukwila, Washington 98188 -2544 South Base Component Supply Shop Chief s Office Remodel 12000 East Marginal Way South Permit Nos. D08 -403 and M08 -207 Dear Mr. Benedicto: By this letter King County Metro is requesting a 180 day extension of the above permits. Due to budget issues for Metro Transit, the project was put on hold. We hope that the authorization to move forward with construction will be given in the next few months. If you have any questions, please feel free to call me at (206) 684 -1334 or our Project Manager, Ken Madden at (206) 684- 1374. Gerrie Jackson, SR/WA Real Property Agent ExP oi©i 6,4 6 IT*1 RECEIVED Cmr OF TUKWILA FEB 26 2009 Penuz CENTER 02 -02 -2009 GERRIE JACKSON 201 S JACKSON ST KSC -TR -0431 SEATTLE WA 98104 RE: Permit No. M08 -207 12000 EAST MARGINAL WY S TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a fmal inspection by the City of Tukwila Building Division. Per the International Building Code and/or the Intemational Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or fmal inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 03/01/2009 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician xc: Permit File No. M08 -207 city of Tukwila Department of Community Development Jack Pace, Director Jim Haggerton, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 ACTIVITY NUMBER: M08 -207 PROJECT NAME: METRO COMPONENT SUPPLY SITE ADDRESS: 12000 EAST MARGINAL WAY S X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # After Permit Issued DEP RTM NTS: ding Division Public Works ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Please Route Documents/routing slip.doc 2 -28-02 PLAN REVIEW /ROUTING SLIP TUES/THURS RO TING: i MIA Ott Fire Prevention Structural Review Required Structural n Permit Coordinator Incomplete ❑ Planning Division DUE DATE: 08 -19 -08 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required C REVIEWER'S INITIALS: DATE: DUE DATE: 09 -16 -08 APPROVALS OR CORRECTIONS: Approved IT Approved with Conditions [A Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 EMPLOYERS MUTUAL CASUALTY CO S311677 06/25/2003 Until Cancelled 06/26/2003 11/15/2005 $12,000.00 06/26/2003 Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 1 ALASKA NATIONAL INS CO 03FLS30854 06/24/2003 Until Cancelled 06/26/2003 11/15/2005 $2,000,000.00 06/26/2003 Name Role Effective Date Expiration Date KANYER, JEFFREY PRESIDENT 06/26/2003 KENNEY, PETER VICE PRESIDENT 06/26/2003 CHASE, TODD VICE PRESIDENT 06/26/2003 11/15/2005 Untitled Page General /Specialty Contractor A business registered as a construction contractor with LBtI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company RCNW 4252549999 PO BOX 188 RENTON WA 98057 KING CORPORATION UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License MCCANTE979K3 Next License Associated License Specialty 1 GENERAL Specialty 2 UNUSED 602286010 ACTIVE RCNW*CN978L6 CONSTRUCTION CONTRACTOR 6/26/2003 6/26/2009 Business Owner Information Bond Information Insurance Information • Page 1 of 1 https: // fortress .wa.gov /lni/bbip/Detail. aspx ?License= RCNW *CN978L6 09/02/2008 King County HIEFS FFICE REM MI ■It ; L kr 44 i. I ' 1,1 I ' "A.,••••••••+:i'". "•;• t',1 Department of Transportation Transit Dvision I— REVISIONS No changes shall be made to thf scorp of work without prior approval of Tukwila Building Division. ! will roquire a new elm sOmittal -., Prlrlf. !Ian r Plat- roview approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Fie! opy and comitions is acknowledged: AUGUST 11, 2008 FILE COPY Permit By Date: ',..)EPARATE PERMIT REQUIRED FOR: 0 Mechanical Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION MOB 207 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 2 2 2 08 City 0 tj kwila BUILDING DIYISICIN DEL City of Tukwila I on I k iL RECEIVED AUG 15 2009 PERMIT CENTER DRAWING NO: G1.00 SHEET NO: OF 0 1 25 .d 11 1n 11Iu' .nIIn1111111III11 A 12t7thPI KENT RENTON AUBURN ' 124Lri s (PROJECT BUILDIN WITHIN SITE) REVISION PROJE VICINIT hPI 1 i MAPLE VALLEY BLACK DIA •ND PRESTON APP'D FALL CITY 22rd St CONTRACTOR STAGING AREA SNOOUALM ARCHITECTURAL SYMBOLS MATERIAL SYMBOLS WALL TYPES REGISTERE A R �M STATE OF WASHINGTON KEY NOTES REVISION SYMBOL ROOM IDENTIFICATION OFFICE- ROOM NAME WALL TYPE NO. NOTE NUMBER ITEM LETTER ROOM NO. COMPACTED EARTH SAND GRAVEL OR CRUSHED ROCK WOOD -ROUGH (Sc CONTINUOUS WOOD - BLOCKING PLYWOOD GYPSUM WALLBOARD BATT INSULATION RIGID INSULATION CONCRETE CMU STEEL WOOD FINISH DRAWN: BP CHECKED: RECOMMENDED: IBIS NO: WORK REQUEST: CONTRACT NO: SITE LOCATION NO: ONE INCH AT FULL SIZE i 1.. IF NOT ONE INCH, SCALE ACCORDINGLY King County Department of Transportation PROJECT DATA PROJECT SITE ADDRESS: 12200 EAST MARGINAL WAY SOUTH TUKWILA, WA 98168 BUILDING USE: SEISMIC ZONE: 3 PROPERTY ZONING: PROPOSED WORK: REPAIR FACILITY FOR METRO VEHICLE FLEET KING COUNTY: MP INTERIOR REMODEL AND ADDITION TO CHIEFS OFFICES. kEVIEWEEi FOR CODE COMPLIANCE APPROVED AUG 2 2 2008 1 City Of Tuk wil a piNG DIVISIO DRAWING NO: SHEET NO: OF 02 25 SEA TTLE VASHON ISLAND A A SECTION DES MOINES . dI11111111 YI 1111 1 5 SCALE: 1 " =1' -O" VICINITY MAP NOT TO SCALE NOT TO SCALE A3.01 01 LOCATION MAP TYPICAL SECTION AND DETAIL REFERENCING SYSTEM (1) THE SECTION IS CUT ON DRAWING A101: SECTION LETTER ELEVATION LETTER DRAWING ON WHICH SECTION /ELEVATION APPEARS. (2) ON DRAWING A105 THIS SECTION IS IDENTIFIED: SECTION LETTER ,/ DRAWING ON WHICH SECTION A1.OY WAS TAKEN. (3) DETAILS ARE CROSS - REFERENCED IN A SIMILAR MANNER, EXCEPT THAT DETAILS ARE IDENTIFIED BY NUMBERS RATHER THAN BY LETTERS. DATE GENERAL PROJECT NOTES CONSTRUCTION OF THIS PROJECT SHALL BE IN COMPLIANCE WITH ALL APPLICABLE CODES, ORDINANCES AND REGULATIONS. CONTRACTOR SHALL VERIFY SIZES AND LOCATIONS OF ALL OPENINGS FOR MECHANICAL EQUIPMENT, ELECTRICAL EQUIPMENT, OWNER SUPPLIED EQUIPMENT, AND OTHER EQUIPMENT, AS WELL AS SHOP DRAWINGS AS REVIEWED BY THE KING COUNTY PROJECT REPRESENTATIVE (KCR) BEFORE PROCEEDING WITH WORK. CUTTING: CUT EXISTING CONSTRUCTION USING METHODS LEAST LIKELY TO DAMAGE ELEMENTS RETAINED OR ADJACENT CONSTRUCTION. PATCHING: RESTORE EXPOSED FINISHES OF PATCHED AREAS AND EXTEND FINISH RESTORATION INTO RETAINED ADJOINING CONSTRUCTION IN A MANNER THAT WILL ELIMINATE EVIDENCE OF PATCHING AND REFINISHING. IF A PORTION OF A PAINTED SURFACE IS PATCHED AND REPAIRED, REPAINT ENTIRE SURFACE TO NEAREST NATURAL HORIZONTAL AND VERTICAL BREAKS IN WALL SURFACE. MATCH EXISTING FINISH AND COLOR OR AS DIRECTED BY THE KCR. 5. ALL DIMENSIONS ARE FROM FACE OF CONCRETE AND /OR FACE OF STUD AND CENTERLINE OF COLUMNS, UNLESS NOTED OTHERWISE. 6. EACH INSTALLER SHALL BE RESPONSIBLE FOR VERIFICATION AND COORDINATION WITH OTHER INSTALLERS TO SECURE COMPLIANCE OF DRAWING AND SPECIFICATIONS CONCERNING THE ACCURATE LOCATION OF STRUCTURAL MEMBERS AND OPENINGS FOR MECHANICAL, ELECTRICAL AND MISCELLANEOUS EQUIPMENT. DO NOT SCALE DRAWINGS. THE CONTRACTOR SHALL USE DIMENSIONS AS SHOWN AND ACTUAL FIELD MEASUREMENT. NOTIFY THE KCR OF ANY DISCREPANCIES. 8. GENERAL CONTRACTOR TO COORDINATE ALL TRADES. 0 arai jackson ellison murakami LLP ARCHITECTURE 1 URBAN DESIGN 1 INTERIORS 2300 seventh avenue seattle, washington 98121 phone: 206.323.8800 fax: 206.323.8518 internet: www.araijackson.com BP ABBREVIATIONS A.B. ACOUS. A.F.F. ARCH. BLDG. BLKG. B.O. C.J. C.L. CLG. CLR. C.M.U. COL. CONC. CONT. CPT. CTR. DEMO. DIA. DIM. DN. DR, DTL. DWG. EA. E.J. EL. ELEC. EQ. EQUIP. BUILDING BLOCKING BOTTOM OF EACH EXPANSION JOINT ELEVATION ELECTRICAL EQUAL EQUIPMENT (E), EXIST. EXISTING EXT, EXTERIOR F.E.C. FF. FIN. FL. F.O. F.O.F. F.O.S. F. GA. GAUGE GALV. GALVANIZED GL. GLASS DESIGNED: AT ANCHOR BOLT ACOUSTICAL ABOVE FINISH FLOOR ARCHITECTURAL CONTROL JOINT CENTERLINE CEILING CLEAR CONCRETE MASONRY UNIT COLUMN CONCRETE CONTINUOUS CARPET CENTER DEMOLISH, DEMOLITION DIAMETER DIMENSION DOWN DOOR DETAIL DRAWING FIRE EXTINGUISHER CAB. FINISH FLOOR FINISH FLOOR FACE OF FACE OF FINISH FACE OF STUDS FOOT OR FEET PROJECT MANAGER: KEN MADDEN APPROVED: H.M. HORIZ HSS INSUL. IN. INCL. I NT. KCR MAX. MECH. MTL. MFR. MIN. MISC. N.I.C. N.T.S. O.C. O.F. OPNG. OPP. PLYWD. PT. PL. R.D. REF. REQD. RM. SCHED SECT. S.F. SHT, SHTHG. SIM. SPECS. STL. STOR. VERT. VFY. W/ W/O CALE: AS INDICATED HOLLOW METAL HORIZONTAL HOLLOW STEEL SECTION INSULATION INCH INCLUDING) INTERIOR KING COUNTY REPRESENTATIVE MAXIMUM MECHANICAL METAL MANUFACTURE R MINIMUM MISCELLANEOUS NOT IN CONTRACT NOT TO SCALE ON CENTER OVER FLOW OPENING OPPOSITE PLYWOOD PAINT PLATE ROOF DRAIN REFERENCE REQUIRED ROOM TYP. TYPICAL U.N.O SCHEDULE SECTION SQUARE FEET SHEET SHEATHING SIMILAR SPECIFICATIONS STEEL STORAGE UNLESS NOTED OTHERWISE VERTICAL VERIFY WITH WITHOUT SHEET INDEX SHEET 1 2 3 4 5 6 7 8 9 10 11 12 13 14 DWG NO. 01.00 01.01 A1.00 A1.01 A2.00 A3.00 A3.01 A3.02 50.01 51.01 52.01 52.02 52.03 M0.01 15 M0.02 SCHEDULES 16 M1.01 17 M2.01 PARTIAL PLANS, ELEVATIONS, AND DETAILS E0.01 ELECTRICAL SYMBOLS, LEGEND AND ABBREVIATION 19 E1.01 DEMOLITION FLOOR PLAN - POWER AND LIGHTING 20 E1.02 DEMOLITION FLOOR PLAN - COMMUNICATION AND DATA 21 E1.03 FLOOR PLAN - POWER AND LIGHTING 22 E1.04 SITE AND ROOF PLAN POWER 23 E1.05 FLOOR PLAN - COMMUNICATION AND DATA 24 E6.01 ONE -LINE DIAGRAM 18 25 E . SCHEDULES M O 2O 7 0 METRO TRANSIT DIVISION COMPONENT SUPPLY CENTER CHIEFS OFFICES REMODEL GI- HRAL PROW -CT CT \OT1- S DATA DESCRIPTION COVER SHEET GENERAL NOTES / PROJECT DATA CODE ANALYSIS / DEMOLITION PLAN FLOOR PLAN / REFLECTED CEILING PLAN ELEVATIONS / WALL SECTIONS / SCHEDULES D ETAILS DETAILS DETAILS GENERAL NOTES FLOOR PLAN / ROOF PLAN DETAIL SHEET DETAIL SHEET DETAIL SHEET ' LEGEND, ABBREVIATIONS, NOTES, 2006 SEC, SCHEDULES AND INDEX FLOOR PLAN - MECHANICAL DEMOLITION AND NEW RECEIVED AUG 15 2000 PERMIT CENTER DATE: 8/11/08 MECHANICAL LEGEND GENERAL NOTES 2006 WSEC COMPLIANCE GENERAL ABBREVIATIONS 1 . THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON DRAWINGS, DIAGRAMS, AND AS DESCRIBED IN SPECIFICATIONS. 2. INSTALL ALL MECHANICAL WORK AS HIGH AS POSSIBLE, TIGHT TO STRUCTURE ABOVE 3. THE MECHANICAL PLANS ARE DIAGRAMMATIC IN NATURE AND DO NOT ATTEMPT TO SHOW ALL REQUIRED OFFSETS. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR CONSTRUCTION DETAILS. 4. ITEMS NOTED "TYPICAL" OR "TYP" ON ANY SHEET APPLY TO THAT PARTICULAR SHEET. 5. COORDINATE WITH SPECIFICATIONS. 6. PROVIDE NEC CODE MINIMUM HORIZONTAL AND VERTICAL WORKING CLEARANCES FOR ALL ELECTRICAL PANELS AND EQUIPMENT. OFFSET MECHANICAL WORK AS REQUIRED. 7. COORDINATE ALL MECHANICAL WORK WITH THAT OF OTHER TRADES TO INSURE PROPER INTERFACE OF THEIR WORK WITH THE WORK OF THIS CONTRACTOR, PROVIDE COORDINATED SHOP DRAWINGS PRIOR TO FABRICATION AND INSTALLATION. 8. ALL DUCTWORK SIZES SHOWN ARE INSIDE CLEAR. ADD APPROPRIATE DIMENSION FOR INSULATION OR DUCT LINER TO OBTAIN "TOTAL" DUCT SIZE. 9. INSTALL FIRE DAMPERS AT ALL LOCATIONS WHERE DUCTS PENETRATE FIRE RATED WALLS. DAMPER FIRE RATING SHALL BE 1 -1/2 HOUR UNLESS NOTED OTHERWISE, COORDINATE DAMPER ACCESS WITH GENERAL CONTRACTOR AND ELECTRICAL CONNECTIONS WITH ELECTRICAL CONTRACTOR. 10. REFER TO ARCHITECTURAL PLANS AND ELEVATIONS FOR EXACT LOCATION OF ALL GRILLES. 11. PROVIDE TRANSITIONS AS REQUIRED TO CONNECT DUCTWORK TO FANS AND OTHER MECHANICAL EQUIPMENT. 12. PROVIDE GRILLE FRAMES COMPATIBLE WITH ARCHITECTURAL WALL TYPE. REFER TO ARCHITECTURAL PLANS FOR WALL TYPE. 13. COORDINATE EXACT LOCATIONS OF ALL ROOM THERMOSTATS AND /OR ROOM TEMPERATURE SENSORS WITH ROOM EQUIPMENT AND PROJECT REPRESENTATIVE PRIOR TO INSTALLATION. 14. PROVIDE A VOLUME DAMPER FOR EACH SUPPLY, RETURN AND EXHAUST OPENING AND IN BRANCHES WHERE THREE OR MORE OPENINGS ARE ASSOCIATED WITH THE BRANCH AND ELSEWHERE AS NOTED ON THE DRAWINGS OR SPECIFICATIONS. 15. PROVIDE 1" THICK DUCT LINER IN ALL RECTANGULAR SUPPLY AIR DUCTWORK DOWNSTREAM OF AIR TERMINAL UNITS UNLESS NOTED OTHERWISE. 16. PROVIDE 1" THICK DUCT LINER IN ALL RECTANGULAR RETURN AIR AND TRANSFER AIR DUCTWORK UNLESS NOTED OTHERWISE. 1. HVAC EQUIPMENT SHALL HAVE MINIMUM PERFORMANCE AT SPECIFIED RATING CONDITIONS NOT LESS THAN THE VALUES INDICATED IN TABLE 14-1A THROUGH 14-10 AND 1411.1 OF THE WSEC AND AS INDICATED ON THE CONTRACT DOCUMENTS. 2. PROVIDE DEADBAND BETWEEN HEATING /COOLING SPACE SENSOR SETPOINTS OF 5 DEGREES AS REQUIRED BY REQUIRED BY SECTION 1412.2 OF THE WSEC OR AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES. 3. HVAC SYSTEMS SHALL BE EQUIPPED WITH AUTOMATIC CONTROLS CAPABLE OF ACCOMPLISHING SETBACK OR SHUTDOWN DURING UNOCCUPIED PERIODS AS REQUIRED BY SECTION 1412.4 OF THE WSEC AND AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES. . ALL DUCTWORK SHALL COMPLY WITH SMACNA STANDARDS FOR CONSTRUCTION OF GALVANIZED DUCTWORK. ALL DUCTWORK SHALL BE SEALED AS REQUIRED BY SECTION 1414.1 OF THE WSEC. DUCT TAPE NOT ALLOWED. DUCTWORK STATIC PRESSURE AND SEAL CLASS: WATER COLUMN SEAL CLASS SYMBOL DESCRIPTION AC AIR CONDITIONING UNIT AMP AMPERE INDICATES NEW WORK HEAVY LINE ASME AMERICAN SOCIETY OF LIGHT LINE INDICATES EXISTING WORK MECHANICAL ENGINEERS OR BACKGROUND BHP BRAKE HORSEPOWER BRNZ BRONZE CENTERLINE ' CD CONDENSATE DRAIN / / / / //r EXISTING WORK TO BE REMOVED CFH CUBIC FEET PER HOUR PIPELINE NORMAL DIRECTION OF FLOW CFM CUBIC FEET PER MINUTE ■ - CLG CEILING /COOLING 1 KEY NOTE CALLOUT CO CLEANOUT COMM COMMUNICATION AA REVISION CALLOUT COMPR COMPRESSOR f2 TO 2 INCHES SEAL TRANSVERSE JOINTS 5. ALL DUCTWORK SHALL BE INSULATED AS REQUIRED BY SECTION 1414.2 OF THE WSEC AND AS DESCRIBED IN SECTION 15081 OF THE PROJECT MANUAL. (110 i GOND CONDENSER /CONDENSATE PLUMBING FIXTURE OR DRAIN CALLOUT, CW COLD WATER SEE SCHEDULE CU CONDENSING UNIT DB DRY BULB /DECIBLE POINT OF CONNECTION DCCI DURA COATED CAST IRON DN DOWN DUCT TYPE LOCATION R -VALUE SUPPLY /RETURN NOT WITHIN CONDITIONED SPACE R -7 (INCLUDE APPROVED WEATHERPROOF BARRIER) EF -1 EQUIPMENT CALLOUT, SEE SCHEDULE DWG DRAWING CD2 -300 DIFFUSER OR GRILLE CALLOUT, SEE SCHEDULE EF EXHAUST FAN EG EXHAUST GRILLE N.....,., VOLUME FLOW RATE (CFM), NONE INDICATED ELEC ELECTRICAL FOR TRANSFER GRILLE ELEV ELEVATOR EMERG EMERGENCY DIFFUSER OR GRILLE TYPE ESP EXTERNAL STATIC PRESSURE AiLk DETAIL CALLOUT: F FAHRENHEIT SUPPLY WITHIN CONDITIONED SPACE R -3.3 6. SUPPLY AIR TEMPERATURES SHALL BE AUTOMATICALLY RESET AS REQUIRED IN SECTION SUPPLUPPL AND 1432.2.2 OF THE WSEC OR AUTOMATICALLY DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES. 7 • SIMULTANEOUS HEATING AND COOLING TO INDIVIDUAL ZONES SHALL BE PROHIBITED AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES EXCEPT WHERE PERMITTED IN SECTION 1435, EXCEPTIONS 1 THROUGH 4 OF THE WSEC. 8. INDIVIDUAL ZONE TERMINAL UNITS AND HVAC SYSTEMS SERVING PORTIONS OF THE BUILDING HAVING LESS THAN 24 HOUR OPERATION SHALL BE SHUT OFF DURING UNOCCUPIED PERIODS AS REQUIRED BY SECTION 1432.1 OF THE WSEC AND AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES. 9. MOTOR EFFICIENCY SHALL NOT BE LESS THAN THE MINIMUM CALLOUTS PER TABLE 14 -4 AND SECTION 1437 OF THE WSEC FOR FULL LOAD EFFICIENCIES. 10. RECORD DRAWINGS SHALL BE PROVIDED TO THE OWNER WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE AS REQUIRED BY SECTION 1416.1 OF THE WSEC, THE DRAWINGS SHALL INDICATE THE LOCATION AND PERFORMANCE DATA OF EQUIPMENT, GENERAL CONFIGURATION OF DUCTWORK AND PIPING DISTRIBUTION SYSTEMS, INCLUDING FLOW RATES AS A MINIMUM. 11. OPERATION AND MAINTENANCE MANUALS SHALL BE PROVIDED TO THE OWNER AS REQUIRED BY SECTION 1416.2 OF THE WSEC. PROVIDE ON ELECTRONIC DISK. AS A MINIMUM, THE MANUALS SHALL INCLUDE: 1. SUBMITTAL DATA. 2. OPERATION AND MAINTENANCE DATA FOR EQUIPMENT. 3. NAMES AND ADDRESSES OF SERVICE AGENCIES. 4. HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION. 5. NARRATIVE OF HOW SYSTEM IS INTENDED TO OPERATE. 12. HVAC SYSTEMS SHALL BE BALANCED AS REQUIRED BY SECTION 1416.3 OF THE WSEC. 13. COMMISSIONING SHALL BE PROVIDED AND A REPORT OF COMMISSIONING BE SUBMITTED TO THE OWNER AS REQUIRED BY SECTION 1416.4 OF THE WSEC. M 1.01 INDICATES DETAIL NUMBER FD FLOOR DRAIN /FIRE DAMPER FDC FIRE DEPARTMENT CONNECTION SHEET NUMBER WHERE DETAIL IS DRAWN FLR FLOOR FPM FEET PER MINUTE A/M2.01 ELEVATION REFERENCE FT FEET /FOOT GAR GARAGE GW GARAGE WASTE VENTILATION HB HOSE BIBS HP HORSEPOWER DOUBLE SINGLE DESCRIPTION IE INVERT ELEVATION (BELOW TOP 4 1,.. a.-17- EXHAUST AIR DUCT - TURNING UP OF LEVEL 1 SLAB) TOWARD +.------1 OR IN INCH EXHAUST AIR DUCT - TURNING DOWN KW KILOWATT OR AWAY met TRANSITION LBS POUNDS LF LINEAL FOOT ... 1 ,�, MAX MAXIMUM r MBH BRITISH THERMAL UNIT PER --�- - 1 TURNING VANES IN RECTANGULAR DUCT TURN �• HOUR (THOUSAND) MECH MECHANICAL MIN MINIMUM 90° ELBOW (RADIUS = 1.5 x ELBOW DIAMETER) NC NOISE CRITERIA ORD OVERFLOW ROOF DRAIN RECTANGULAR BRANCH CONNECTION ORWL OVERFLOW RAIN WATER LEADER DRAWING INDEX .. t t WITH 45° TAPER PD PRESSURE DROP PWR POWER EV EvvED FOR M0.01 LEGEND, ABBREVIATIONS, GENERAL NOTES, 2006 WSEC COMPLIANCE AND DRAWING INDEX M0.02 SCHEDULES M1.01 FLOOR PLAN - MECHANICAL DEMOLITION AND NEW M2.01 PARTIAL PLANS, ELEVATIONS AND DETAILS RECEIVE ' AUG 15 2000 v 10 8..... 207 PERMIT CENTER CODE COMPLIANCE APPROVED AUG 2 2 2008 . 2 VOLUME DAMPER RH RELATIVE HUMIDITY RD ROOF DRAIN 1 .----1--- RM ROOM + GRILLE (SIDEWALL) RPM REVOLUTIONS PER MINUTE RWL RAIN WATER LEADER City Of Tukwila 'IT: Z--T---i MOTORIZED CONTROL DAMPER SMACNA SHEET METAL AND AIR CONDITIONING CONTRACTORS' NATIONAL ASSOCIATION SP STATIC PRESSURE /STANDPIPE EQUIPMENT SPD SPEED BUILDIN [MISIQk SPEC SPECIFICATION SYMBOL DESCRIPTION TEMP TEMPERATURE 0 THERMOSTAT OR TEMPERATURE SENSOR TYP TYPICAL 41 CEILING DIFFUSER (FOUR -WAY AIRFLOW) UH UNIT HEATER 01--- RETURN GRILLE WITH BOOT VENT/VOLT VEL VELOCITY W WASTE /WATT PLUMBING AND PIPING WB WET BULB WC WATER COLUMN SYMBOL DESCRIPTION WG WATER GAGE WSEC WASHINGTON STATE ENERGY CODE - A COMPRESSED AIR l PIPE TURNING UP OR TOWARD i s PIPE TURNING DOWN OR AWAY i �• p iu►\a$ D . wA o �I,� 9918 6 4 GISTY.��� ro�va� � 0 arai Jackson ellison murakami LLP ARCHITECTURE I URBAN DESIGN I INTERIORS 2300 seventh avenue Seattle, Washington 98121 p 800 phone: 023 23 e : 2. 8 Internet: www.araijackson.com DESIGNED: J MD --._ PROJECT MANAGER: KEN MADDEN SCALE: NONE �.. a , METRO TRANSIT COMPONENT SUPPLY CHIEFS OFFICES L EGEND ABBREVIATIONS l NOTES 2006 AND D RA\AI DIVISION CENTER REMODEL W I N G INDEX , DATE: 8/11/08 DRAWN: (:DI APPROVED: SITE LOCATION N ONE INCH AT FULL SIZE 1" - C d 1 N G I N E E R S 4200 194th St SW, suite 200 Lynnwood A 98036 , \1 T 425.672.1071 F 425.778.8709 www.CDI King County Department of Transportation CHECKED: RCG IBIS NO: WORK REQUEST: DRAWING NO: Mc�.01 RECOMMENDED: CONTRACT NO: _ No. REVISION BY APP'D DATE I. IF NOT ONE INCH, SCALE ACCORDINGLY SHEET N0: OF 1 25 EXPIRES -21 -zoos HEAT PUMPS - SPLIT SYSTEM MARK LOCATION AC -1 CD2 RM 139A TYPE RM 139A /ROOF MOD CORE CAPACITY FLOW: GPM CAPACITY TYPE DUCTED 10 NOM FACE SIZE: IN TYPE NOM CLG: TONS 1.5 CAPACITY MOTOR RPM 3,500 NET CLG: BTUH 19,100 75 100 DISCH: IN SEER 15 RECEIVER CAPACITY: GAL 0.5 HTG CAP: BTUH 12,300 3/4 ELECTRICAL HTG COP 3.40 MOTOR HP (EA) 1/40 REFRIGERANT R -410A WEIGHT: LBS 6 MCD CONNECTIONS SUCTION LINE: IN 5/8 [1, 2, 3] MODEL 2EC -SPT LIQUID LINE: IN 3/8 [1, 2, 3] DRAIN: IN 3/4 INDOOR SECTION LOCATION RM 139A /ROOF AIRFLOW: CFM [7] 200 ESP: IN WG 0.3 MOTOR HP 1/4 ELEC HEAT: KW 4.8 FILTER TYPE DISPOSABLE WEIGHT: LBS 111 VOLT/PHASE 208/1 FLA 1.4 L.R. AMPS 3.1 OUTDOOR SECTION CU - 1 LOCATION ROOF WEIGHT: LBS 239 VOLT /PHASE 208/1 MCA 12.0 BASIS OF DESIGN MANUFACTURER TRANE MODEL (INDOOR) 4TEC3F18 MODEL (OUTDOOR) 4TWX5018 NOTES [1 - 6] PUMPS - CONDENSATE MARK LOCATION SERVES CP -1 CD2 RM 139A TYPE AC - 1 MOD CORE CAPACITY FLOW: GPM 1 STEEL TDH: FT 10 NOM FACE SIZE: IN TYPE DESCRIPTION INLINE CAPACITY MOTOR RPM 3,500 8x8 DISCH PRESS: PSIG 75 100 DISCH: IN 3/4 MAX SP: IN WG RECEIVER CAPACITY: GAL 0.5 MAX NECK VEL: FPM INLET: IN 3/4 ELECTRICAL VOLT /PHASE 115/1 MOTOR HP (EA) 1/40 TITUS OPER WEIGHT WEIGHT: LBS 6 MCD BASIS OF DESIGN MANUFACTURER LITTLE GIANT [1, 2, 3] MODEL 2EC -SPT NOTES [1, 2, 3] CEILING DIFFUSERS MARK CD1 CD2 TYPE DESCRIPTION MOD CORE MOD CORE MATERIAL STEEL STEEL NOM FACE SIZE: IN 24x24 24x24 CAPACITY NECK SIZE: IN 6x6 8x8 MAX FLOW: CFM 100 200 MAX SP: IN WG 0.05 0.05 MAX NECK VEL: FPM 400 500 MAX NC: [2] 15 15 BASIS OF DESIGN MANUFACTURER TITUS TITUS MODEL MCD MCD NOTES [1, 2, 3] [1 2, 3] EXHAUST GRILLES MARK EG -1 TYPE DESCRIPTION LOUVERED MATERIAL STEEL CAPACITY DUCT SIZE: IN 12x10 MAX FLOW: CFM 200 MAX SP: IN WO 0.02 MAX CORE VEL: FPM 300 MAX NC: — BASIS OF DESIGN MANUFACTURER TITUS MODEL 350RL NOTES [ 1 2, 3 No. REVISION BY AP P' D DATE EXPIRES 5 -21 -2009 NOTES: 1. REFER TO ELECTRICAL DRAWINGS FOR DISCONNECT SWITCHES. 2. PROVIDE EQUIPMENT SUPPORT STAND FOR ROOF MOUNTED OUTDOOR UNIT, REFER TO ARCHITECTURAL DRAWINGS. 3. ROUTE CONDENSATE DRAIN TO NEAREST LAVATORY TAILPIECE DRAIN, SEE PLANS. 4. PROVIDE WITH MICROPROCESSOR THERMOSTATIC PROGRAMMABLE CONTROLLER. 5. HANG INDOOR UNIT FROM EXISTING STRUCTURE ABOVE CEILING SPACE WITH SPRING VIBRATION ISOLATION. 6. INTERLOCK AC-1 WITH EXISTING ROOFTOP UNIT AC -102 TO PREVENT SIMULTANEOUS HEATING AND COOLING. 7. UNIT SET ON LOW SPEED. 0 arai jackson ellison murakami LLP ARCHITECTURE 1 URBAN DESIGN 1 INTERIORS 2300 seventh avenue seattle, washington 98121 phone: 206.323.8800 fax: 206.323.8518 Internet: www.araijackson.com C;Di ENGINEERS 4200 - 194th St SW, Suite 200 Lynnwood, WA 98036 T 425.672.1071 F 425.778.8769 www.CDiENGINEERS.com DESIGNED: JMD DRAWN: CDi CHECKED: RCG RECOMMENDED: PROJECT MANAGER: KEN MADDEN APPROVED: IBIS NO: WORK REQUEST: CONTRACT NO: REVIEWED FUR CODE COMPLIANCE APPROVED AUG 2 2 1008 City Of Tukwila BUILDING DIVISION SCALE: NONE SITE LOCATION NO: NOTES: 1. PROVIDE GRILLES WITH BORDER STYLES THAT ARE COMPATIBLE WITH ADJACENT CEILING SYSTEMS, REFER TO ARCHITECTURAL PLANS. 2. NC BASED ON OCTAVE BANDS 2- 7 SOUND POWER LEVELS MINUS A ROOM ABSORPTION OF 10 DB, MEASURED PER ASHRAE 70 -91. 3. PROVIDE ATTACHED PLENUM. SEE DETAIL 2 ON M2.01. NOTES: 3. PROVIDE DIFFUSERS WITH BORDER STYLES THAT ARE COMPATIBLE WITH ADJACENT CEILING SYSTEMS. REFER TO ARCHITECTURAL PLANS. NC BASED ON OCTAVE BANDS 2 - 7 SOUND POWER LEVELS MINUS A ROOM ABSORPTION OF 10 DB, MEASURED PER ASHRAE 70 -91. PROVIDE ATTACHED PLENUM, INTERNALLY LINED WITH 1" DUCTLINER. SEE DETAIL 1 ON M2.01. NOTES: 1. REFER TO ELECTRICAL DRAWINGS FOR DISCONNECT SWITCH. 2. PROVIDE WITH SHUT OFF ALARM 3. HANG FROM STRUCTURE ABOVE. ONE INCH AT King County FULL SIZE I. Department of Transportation IF NOT ONE INCH, SCALE ACCORDINGLY M o8 2 o7 METRO TRANSIT DIVISION COMPONENT SUPPLY CENTER CHIEFS OFFICES REMODEL SCHEDULES ECEIV D AUG 15 2008 PERMIT CENTER DATE: 8/11/08 DRAWING NO: MO.O2 SHEET NO: OF 1 5 25 No. CD2 -200 EG1 -135 8x6 -- EG1 -135 EG1 -200 10x6 �-- 6x8 5 12x10 12x12 UP AND DN 10x10 10 "0 REVISION SUPPLY AND EXHAUST OVERHEAD FROM AC -102 FLOOR PLAN - MECHANICAL SCALE: %4 " =1' -O" KEY NOTES: O TYPICAL 24x24 CEILING SUPPLY DIFFUSER. 02 TYPICAL 12x10 CEILING EXHAUST GRILLE. • RELOCATED EXISTING COMPRESSED AIR VALVE STATIONS. CONNECT TO NEW COMPRESSED AIR PIPING. 04 NEW COMPRESSED AIR PIPING EXPOSED ON WALL. REFER TO ELEVATIONS ON M2.01. Q NEW SUPPLY AND EXHAUST DUCTWORK IN CEILING SPACE. CONNECT TO EXISTING DUCT DROPS, IN CEILING SPACE. • NEW SPACE THERMOSTAT TO EXISTING AC -102 ON ROOF. INSULATED DX SUCTION AND LIQUID LINES UP, SECURED TO WALL, TO ROOF. REFER TO PARTIAL ROOF PLAN ON M2.01 FOR CONTINUATION. 0 y4 COPPER CONDENSATE DRAIN UP. REFER TO PARTIAL FLOOR PLAN ON M2.01 FOR CONTINUATION. 0 EXTEND EXISTING FIRE SPRINKLER SYSTEM FOR FULL COVERAGE PER NFPA -13. 10 REFER TO STRUCTURAL AND ARCHITECTURAL DRAWINGS FOR DUCT CONFIGURATION THROUGH OPENING. CD2 -150 BY APP'D DATE B /M2.0 �11�1111ff /% 8 0 . T \/ i 6 "0 8x6 EG1 -135 EXPIRES 5 -21 -2009 PROJECT NORTH CD1 -50 EG1 -45 4x6 8 "0 2300 seventh avenue Seattle, washington 98121 phone: 206.323.8800 fax: 206.323.8518 Internet: www.araijackson.com (TYP) LOW PRESSURE CON PRESSED AIR RISER MAIN RISER 1 A (TYP) 0 arai jackson ellison murakami LLP ARCHITECTURE 1 URBAN DESIGN 1 INTERIORS CDi ENGINEERS 4200 - 194th St SW, Suite 200 Lynnwood, WA 98036 T 425.672.1071 F 425.778.8769 www.CDiENGINEERS.com 12x12 UP AND DN 0 THROUGH WALL AIR CONDITIONER .,�. a r iii m' ��..�.� Issmor migiAlrzoi.cmar.T.101 DESIGNED: JMD DRAWN: CDi CHECKED: RCG RECOMMENDED: PROJECT MANAGER: KEN MADDEN APPROVED: IBIS NO: WORK REQUEST: CONTRACT NO: 12 "% COMPRESSED AIR DROPS AND QUICK DISCONNECT STATIONS SD -10x1 Q. AT 240 CFM EACH EG -10x10 AT 240 CFv EACH 10 "0 SUPPLY AND EXHAUST OVERHEAD FROM EXISTING AC -102 ' Nrol' SCALE: %4 " =1' -0" KEY NOTES: 0 EXISTING THROUGH WALL AIR CONDITIONER TO BE REMOVED. INFILL CMU WALL TO MATCH EXISTING. 0 REMOVE EXISTING COMPRESSED AIR LINE AND DROPS ON WALL TO STATION OUTLETS. SALVAGE STATION OUTLETS, VALVING AND DISCONNECT ASSEMBLIES FOR RELOCATION. CAP PIPE DURING NEW ROOM CONSTRUCTION. 0 REMOVE EXISTING SUPPLY DIFFUSERS AND DUCTWORK BACK TO SUPPLY DUCT DROP THROUGH DECK. 04 REMOVE EXISTING EXHAUST AIR GRILLES AND DUCTWORK BACK TO EXHAUST DUCT DROP THROUGH DECK. EXISTING AIR BALANCE CFM READINGS. SCALE: SITE LOCATION NO: ONE INCH AT FULL SIZE IF NOT ONE INCH, SCALE ACCORDINGLY King County Department of Transportation EG -10x10 AT 240 CFM EACH 0 I mo— CAP PROJECT FLOOR PLAN - MECHANICAL DEMOLITION NORTH i MO SJ O7 3 /4" METRO TRANSIT DIVISION COMPONENT SUPPLY CENTER CHIEFS OFFICES REMODEL LOW PRESSURE COMPRESSED AIR RISER CODE REVIEWED FOR .. VAIN RIS R COMPLIANCE APPROVED AUG 2 2 2008 Cir df Tukwila SI BUILDING DIVI QN. FLOOR PLAN — MECHANICAL DEMOLITION AND NEW RECEIVED AUG 15 200€ PEFIMIT CENTER BUILDING KEY PLAN DATE: 8/11/08 DRAWING NO: M1.01 SHEET NO: OF 16 25 No. CHIEF'S OFFICE REMODEL BELOW INSULATED DX SUCTION AND LIQUID. LINES DN IN HOOD Vii■ Agra va CU -1 REVISION KEY NOTES: 0 SECURE TO CURB. REFER TO ARCHITECTURAL FOR CURB DETAILS. PARTIAL ROOF PLAN - HVAC SCALE: 1/16"=1'— 0" 3 /4 " CD OVER DOOR �- ---___ 1. WEATHER HOOD, 5EE, s I ' 3 /4 "CD DN, SEE M1.01 FOR CONT KEY NOTES: @1 3/ COPPER CD DOWN IN WALL TO 1" AIR GAP FITTING CONNECTED TO LAVATORY WASTE TAIL PIECE. PROVIDE AIR GAP 12x12 ACCESS DOOR ON WALL BELOW LAVATORY. CONDENSATE DRAIN 10' ABOVE FINISHED FLOOR ON WALL. 0 PATCH, REPAIR AND INSTALL NEW TILE TO MATCH EXISTING. PARTIAL FLOOR PLAN - PLUMBING SCALE: 1/16"= BY APP'D PROJECT NORTH PROJECT NORTH DATE PIPE AND CONDUIT THROUGH DUCT HOOD HOOD FLASHING AT ROOF BY OTHERS Y2" CONTROL CONDUIT LIQUID 5 /8" SUCTION 3/ ELECTRIC CONDUIT DIFFUSER (TYP) EXPIRES 5- 212009 3/ COMPRESSED AIR SECURED TO WALL WITH UNISTRUT U —BOLT SYSTEM l NOTES: 1. INSTALL REFRIGERATION PIPING PER MANUFACTURERS RECOMMENDATION. 2. PROVIDE SEISMIC BRACING PER REQUIREMENTS 0 arai Jackson ellison murakami LLP ARCHITECTURE 1 URBAN DESIGN 1 INTERIORS 2300 seventh avenue seattle, washington 98121 phone: 206.323.8800 fax: 206.323.8518 internet: www.araijackson.com SUPPORT, SEE 10 "o 6 A3.02 14x14 0 AIR CONDITIONING UNIT SYSTEM (3 SCALE: NONE COMPRESSED AIR VALVE STATION 36" ABOVE FINISHED FLOOR (TYP) 9 (TYP) • ELEVATION (B SCALE: ! 4 " =1' -0" M1.01 CDIENGINEERS 4200 - 194th St SW, Suite 200 Lynnwood, WA 98 036 T 425.672.1071 F 425.778.8769 www.CDIENG1NEERS.com • DESIGNED: JMD DRAWN: CDi CHECKED: RCG M2.01 RECOMMENDED: 3 44" BRANCH LINE TO VALVE STATIONS ELEVATIO\ SCALE: %4 " =1' -0" APPROVED: IBIS NO: WORK REQUEST: CONTRACT NO: FLEX DUCT (TYP) VIBRATION ISOLATORS (TYP) REFER TO SPECIFICATION SECTION 15241 /2" ROD (TYP) 3 /4" CONDENSATE DRAIN /TRAP ROUTE TO NEAREST WASTE, TERMINATE WITH AIR —GAP FITTING REFER TO PLANS FOR RETURN / CONFIGURATION COMPRESSED AIR MAIN CONDUIT • PROJECT MANAGER: KEN MADDEN CONNECT TO EXISTING 3 /4" M1 .01 SITE LOCATION NO: SCALE: AS NOTED ONE INCH AT FULL SIZE 1„ H IF NOT ONE INCH, SCALE ACCORDINGLY 3 /4" COMPRESSED AIR SECURED TO WALL WITH UNISTRUT U —BOLT SYSTEM • • COMPRESSED AIR VALVE STATION King County Department of Transportation METRO TRANSIT DIVISION COMPONENT SUPPLY CENTER CHIEFS OFFICES REMODEL PARTIAL PLANS, ELEVATIONS AND DETAILS SHEET METAL DIFFUSER CAP 1" SOUNDLINING, INSIDE CLEAR DIMENSIONS SAME SIZE AS DIFFUSER NECK CEILING DIFFUSER SHEET METAL CAP 1" SOUNDLINING, INSIDE CLEAR DIMENSIONS SAME SIZE AS GRILLE CEILING GRILLE CEILING DIFFUSER SCALE: NONE CEILING GRILLE SCALE: NONE X108 -207 i REVIEWED FOR - CODE COMPLIANCE APPROVED AUG 2 2 2008 City Of Tukwila �'L.pINGi. VrSIQN SHEET METAL STUB DUCT DUCT STRAP FLEXIBLE DUCT CEILING, T —BAR SHOWN, SEE ARCHITECTURAL CEILING PLAN BRANCH DUCT MINIMUM M2.01 CEILING, T —BAR SHOWN, SEE ARCHITECTURAL CEILING PLAN (2 M2.01 RECEIVE AUG 15 2000 PERMIT CENTER DRAWING NO: M2.01 DATE: 8/11/08 SHEET NO: OF 17 25