Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M08-225 - MATTRESS DEPOT
MATTRESS DEPOT 16901 SOUTHCENTER PY STE 101 M08 -225 Parcel No.: 2623049011 Address: 16901 SOUTHCENTER PY TUKW Suite No: Tenant: Name: MATTRESS DEPOT Address: 16901 SOUTHCENTER PY , TUKWILA WA Owner: Name: OCM ESCROW ADMINISTRATION Address: 1717 MAIN ST 8TH FL- ESCROW , DALLAS TX Contact Person: Name: KEO TORRE Address: 727 S KENYON ST , SEATTLE WA Contractor: Name: EVERGREEN REFRIGERATION LLC Address: 727 S KENYON ST , SEATTLE WA Contractor License No: EVERGRL954R2 Value of Mechanical: $20,000.00 Type of Fire Protection: Furnace: <100KBTU 0 >100K BTU 0 Floor Furnace 0 Suspended/Wall/Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System.... 0 Air Handling Unit <10,000 CFM 0 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 1 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial/Industrial 0 doc: IMC -10/06 Cityllf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us MECHANICAL PERMIT Permit Number: Issue Date: Permit Expires On: DESCRIPTION OF WORK: USING EXISTING ROOFTOP HVAC UNIT INSTALL DUCTWORK, DIFFUSSERS. INSTALL EXHAUST FANS IN RESTROOM EQUIPMENT TYPE AND QUANTITY * *continued on next page ** M08 -225 Phone: Phone: 206 -763 -1744 Phone: 206 763 -1744 Expiration Date: 01/06/2010 M08 -225 09/19/2008 03/18/2009 Fees Collected: $395.00 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP/1,750,000 BTU 0 Fire Damper 0 Diffuser 14 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 Printed: 09 -19 -2008 Permit Center Authorized Signature: Print Name: doc: I MC -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: M08 -225 Issue Date: 09/19/2008 Permit Expires On: 03/18/2009 L0 JQ(L T 2 J Date: "L — t 4 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perfo ance of work. I am uthorized to sign and obtain this mechanical permit. Signature: Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M08 -225 Printed: 09 -19 -2008 Parcel No.: 2623049011 Address: Suite No: Tenant: 16901 SOUTHCENTER PY TUKW MATTRESS DEPOT 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: M08 -225 ISSUED 09/09/2008 09/19/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: ** *FIRE DEPARTMENT CONDITIONS * ** 12: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 13: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 14: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 15: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) doc: Cond -10/06 M08 -225 Printed: 09 -19 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us 16: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 17: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 18: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 19: An electrical perrnit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 20: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 21: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 22: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond - 10/06 * *continued on next page ** M08 -225 Printed: 09 -19 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doc: Cond -10/06 c?,,,L, 5, .4/t,-.0e/Z,c9/-1..--. Date: (9�d M08 -225 Printed: 09 -19 -2008 7 Mail Address: 'fie Oa Sir a d.Gt n fry 0( • C,�i AI Site Address: Vy q (1 Ace rim 'r2w -10-491 4 t. Mel De poi Property Owners Name: 0 C n•1 C vrr s-- 14461 n t s flu fit") Tenant Name: Mailing Address: 11 1 rev 'fl r+, C> U frt City Name: ¥; U Mailing Address: 1 '- 7 5- la I'-vv, ompany Name: Mailing Address: Contact Person: /7 PPf •C 4 1 — E -Mail Address: Contractor Registration Number: Contact Person: E -Mail Address: CITY OF TUKWI Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Q:\ Applications \Forms- Applications On Line13 -2006 - Mechanical Permit Application.doc Revised: 4 -2006 bh MECHANICAL PERMIT APPLICATION v .& V ' 1 6/..9 ti01 fb r1 z-? S- 'Y0M1 s 4 VEt P-z E -Mail Address: `O S I Z Mechanical Permit No. . Project .No: (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** King Co Assessor's Tax No.: 2L1 30 q'Q 1 j Suite Number: 4& T PER$ON� 'j' ,s a T.`T: V�t^:,:r» sNiti;`R t J- r'4h.. r ". ni°T . ±7; wh do contact when your permit is read to y , "i�' `rY` .{ ''��,. �,�, �i' ,w j7! " • -5., j Ki 1 :F! Day Telephone: 2.4» - -? it ._ 17 4 L/ City Fax Number: MECHANI A JJC 1 . ►CTORSINEORMATI LLC, City Day Telephone: Fax Number: City Day Telephone: Fax Number: New Tenant: Ei .... Yes .No ir State Floor: 1 0 1 7f ca State Zip - 1,c it ° - 743 - a� State Zip 6 , 1 -- 11 4 1 4 1 Zato -- 7 tt' 3• 2,1 G1 Expiration Date: k / 4- / / Zip F. REG . -All plans m sAbVc et st m NArcha bo tir Re ors Company Name: Mailing Address: City Day Telephone: Fax Number: State State Zip ENGINEER OF RECORD: All plans must be wet"stainped by Engineer of Record} • Company Name: Mailing Address: Zip 2ontact Person: Page 1 of 2 Unit Type: Qty, Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace<100K BTU 0 Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser 4,4 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct 1 b I � Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator — Comm/Ind Other Mechanical Equipment Valuation of Project (contractor's bid price): $ ■ Pa) ° Scope of Work (please provide detailed information): Z.vj ) } `t - C't hc, v H- le-e 1 +fj/!/dl\ l-7`'( - h ) sj 9 1 t v� Use: Residential: New .... ❑ Commercial: New .... ❑ Signature: Print Name: Date Application Accepted: 9 J(/ 4-14p-v- viik i c µ l BUILDING OWNE ; OR AU 11 RIZED AGENT: Q: Applications\Forms- Applications On Lin&3 -2006 - Mechanical Permit Application.doc Revised: 0 -2006 bh Replacement .... ❑ Replacement .... Indicate type of mechanical work being installed and the quantity below: (4e/i ex r� 1 �Z J pc (-I " i ‘ct-J . ( . G i'1 e, r Fuel Type: Electric ❑ Gas ....D Other: .PE RM PLI ATIO p ll��i to ll;perthi ip ]thns applicati ' i , ti.a/�,� n:. ?.k.iYT ' E { `.i= 3.'p:•c`>;..i 4c4�i, .i. , Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Mailing Address: "1 S - h- fu, .}, Date: R / Day Telephone: SO. Z t o '7— H City State Zip Date Application Expires: 3--9 -05 Staff Initials: Page 2 of 2 1 Receipt No.: R08 -03192 Initials: WER User ID: 1655 City of Tukwila Payee: EVERGREEN REFRIGERATION Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206431 -3665 Web site: http://www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 003287 395.00 ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES RECEIPT Parcel No.: 2623049011 Permit Number: M08 -225 Address: 16901 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 09/09/2008 Applicant: MATTRESS DEPOT Issue Date: Account Code Current Pmts 000.322.102.00.0 316.00 000/345.830 79.00 Total: $395.00 Payment Amount: $395.00 Payment Date: 09/09/2008 11:19 AM Balance: $0.00 - • +.- rn Inrt doc: Receiot -06 Printed: 09 -09 -2008 Project Type o- pect / /* - / Address: 5 i S . / g Date Called: r Special Instructions: Da a Wanted: 1 .– S- d . p.m. Requester: Phone No: INSPECTION RECORD INSPE ON N0. R Lain a copy with permit ' I rd � P RMIT NO. CITY OF TUKWILA BUILDING DIVISION t r- (206)431 -3670 6300 Southcenter Blvd., #100, Tukwila, WA 98188 COMMENTS: 1 4)/01,74 ao,o 7g3/49-7 IDatej 3- 5 Approved per applicable codes. Corrections required prior to approval. T REINSPECTION FEE RE o UIREI Prior to inspection, fee must be p- t 6300 Southcenter Blv ' ., Suite 00. Call to schedule reinspection. Rece °.t No.: (Date: 1 Project: 4 ��e.. / .fJT Type of Inspection: / � . )-4.. � /� ,{� / ��/ c C 4" Ad ress: Date Called: Special Instructions: / Date Wanted: _ Request CL7i,. p.m. Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION PERMIT NO. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -360 Approved per applicable codes. Corrections required prior to approval. COMMENTS: /44 it Inspector: Dat v rr $60.00 REINS ECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 1 Receipt No.: 'Date: 4:t3 Receipt No.: �FU�+. 5h11M+.Ai �Ah1s.lffiA/3.a.��1.v INSPECTION RECORD Retain a copy with permit 'Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspec'or: 'Date: ~Vy ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. a a - e.wlkY! Type of Infsppecction: 1 2 . • / Pro' ct: (( 0 ---- Ad ` ( S 6 0 Ad . //� ` Date Called: Special Instructions: i / e Wanted: -3 - a Requester: Phone No: 4:t3 Receipt No.: �FU�+. 5h11M+.Ai �Ah1s.lffiA/3.a.��1.v INSPECTION RECORD Retain a copy with permit 'Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspec'or: 'Date: ~Vy ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. a a - e.wlkY! COMMENTS: TL ;s WAS Cf a 1 J, LAY-6 ") [)r M T d . ` CV " 'rim-4/t S f /t4c) 22- At 44 e4 10 - ST Phone No _ S ( 2,34 — 2 3 f1 i ,LI) 0 S P-i `-1 -- ( (- c - . u e1,c 1 A Project: Type of Inspecti n: OAn Cd r Address: s� v' SC �� Date Called: Special Instructions: Q L S I 4 � + ` fl 0 Date Wanted: �/ � t7 "2 �" or p.m. Requester: Phone No _ S ( 2,34 — 2 3 f1 r E1 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Corrections required prior to approval. Inspector: Date: / 0 2 ® $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Pro �1 gyp \�il 5 i Type of nspection l � v.. "\. " i Address: Date Called: Special Instructions: / Date Wanted, ,^ V i^ - , 1 68. a.m p.m. . Requester: Phone No: INSPECTION RECORD Retain a copy with permit .1 /L1 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300.Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 -ee-3 Approved per applicable codes. Corrections required prior to approval. COMMENTS: AeAJ‘ c.ei\N Inspector: I i » r $60.00 REINSPECTION P REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: (Date: Project: n #01/5 / 4) Type f Inspection: ) 7 / ( X. L' S al PI Address /L / D / 502/74eln hie,- Date Called: Special Instructions: / / Date Wanted: 4. �a.m Requester: . • Phone No: .0d'' -3/g2 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3 U Approved per applicable codes. COMMENTS: Inspe Dr s, z_ (c ❑ Corrections required prior to approval: $60.00 REINSPECTION FEE REQUIRED. Prior to Inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: COMMENTS 1 Type of Ins ` � (f� c,-;. f fro. f� f 2 Address: ; ,. Suite #: ' Contact Person: f.,. r u i trri , hI(p4 R• Pr _ "' R e S" K, i I t t° t t .1 A) 9 ` "S; , i -f !° `�.._. � ! fi e..... Proect: J f' 1 Type of Ins ` � (f� c,-;. f fro. f� f 2 Address: ; ,. Suite #: ' Contact Person: f.,. r Special Instructions: Occupancy Type: Phofie No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre- Fire: Permits: Occupancy Type: INSPECTION NUMBER 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT App'Foved per applicable codes. PERMIT NUMBERS ri Corrections required prior to approval. Inspector: Date: iH rs.. $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 Project: M u ++„ 53 -}-4 De ffo Type of Inspection: FA F (/ A rc t, /-1\-1c, I Address: / p q o ) 5.� k 1 ,, 1- N Suite #: Contact Person: 1Zyc,., Sty- c'i 14 Special Instructions: Phone No.: )-u`ti- )o 13/1 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: ,4 t6 t— r � (e , ,Ac. v Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER East, Tukwila, Wa. 98188 206- 575 -4407 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT PERMIT NUMBERS Corrections required prior to approval. COMMENTS: O /k Inspector: ,a1, Date: Hrs.: $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 , T.F.D. Form F.P. 113 We get (dings built. STRUCTURAL ENGINEERS Engineers Northwest Inc., P.S. MO8 zzs STRUCTURAL CALCULATIONS FOR NEW MECHANICAL UNITS FILE co AT / " 7,71;! NO. SOUTH CENTER RETAIL BUILDING -t , 16901 South Center Parkway Tukwila WA 98188 Jose Parada, PE /SE Nawzad Ahmed September 2, 2008 ENW Project No. 88- 067007 CODE: 2006 IBC / ASCE 7 -05 0 CODE FOR E COMPS CE APPRO SEP 1 8 2008 , ®kwih LION RECEIVED SEP 09 PERMIT CENTER Al o 6869 Woodlawn Avenue NE • Seattle, WA 98115 206.525.7560 • fax 206.522.6698 www.enwseattle.com ENW • • • ENGINEERS NORTHWEST, INC., P.S. — STRUCTURAL ENGINEERS PROJECT # PROJECT , SUBJECT LL 2-S P C D L- 9 6869 WOODLAwN AVE. N. E., #205, SEATTLE, WA 98115 (206) 525--7560 FAX (206) 522-6698 / DATE ADD - riot.) 1 "pc Lorr,it,•:.-,.-5 BY —4 2,2_. PMEINcr 1 ..c6 cb 1.0 10cutiArDonl 0 - F,:f L. 1 /—P;.`; tz^ SHEET 2.- OF 1 5 Nk"L re I 1 (1- ro li, FS•r ',)56 2 PSE • • ENW ENGINEERS NORTHWEST, INC., P.S. - STRUCTURAL ENGINEERS 6869 WOODLAWN AVE. N. E., #205, SEATTLE, WA 98115 (206) 525 -7560 FAX (206) 522-6698 PROJECT # 8 )00 -- 00 PROJECT GOUT L 1 , l� -1 P\ t DATE l T 112-33 SUBJECT NA AUGI - T NO SHEET 3 OF 15 10 `-)1U 0 8.S T N ETuk k -c _Gp, / 1- (YSc 12@E ) 64 / X 3O /, U f 2 ct_ I?OO F C.v(21) 0No rill 7L'� 1c3 HI GJI PSF 2' YSC 1 Q 2�� k ILL ►4 = 29 12s� 16 1-12,c 3 PS - UNIT wr, 120I 1 I lc, y (1\ L 1 3 C� U N I T �1 ! I DcI(0 16 p OF Cu2>3 1t5 11, C LO�lokil��r = $recvle - rm eLU E - IL t I7 roT L izs - q- lb By r C `I 2 s ^ 1 • • IEINJM ENGINEERS NORTHWEST, INC., P.S. ~ STRUCTURAL ENGINEERS PROJECT # D O (0 PROJECT Sc11 Cs(? C, P" �t L SUBJECT ti Mi Lo 14 1NCr P CbNEC19L NOTES ( SH AT Z( 21-IF V4 (DC./x-) (b _2400 CSO Cmi\rri svE 2 M6M6a5 ; 2y1 Ve) (DF /cF) Cab - 21400 PST) ® �0 3A X 2 - 7- GL13 Wog (2 ' (3s.2-S ) _ 4123 PLF *ILL = (25 PSF) (3S ,25 = 43434,25. PLF • ( 3 At X 2 4 GL.Q 423 PI;.- w,.L = `2s PSF-) C 35.25) Sbl ,2S Pty 6869 WOODLAWN AVE. N. E., #205, SEATTLE, WA 98115 (206) 525 FAX (206) 522 P-►4z COAST tG+oj1 SPP kJ Tie \JibTr+ 3s.2S SPAM - Z3- -o" TRIP wicT■ = 35.25 DATE 2 f 2g f wv e 6 SHEET 4 1 OF 15 BY N R — RTV\ \NE\CINT ( y (0 PS) (9 - 4 YFl) = 2O 1_ Z i PL.F- spt - o \ /ti' (Poor„ L.EF"T) RTA = ( 2, PS (y) -4 3/6 s 14)9 ,y 1 PLF (, SPRN = 1 1/2_" Mt0 se/ Rev: 580004 User. KW-0808898, Ver 5.8.0, 1- Dec -2003 (c)1983 -2003 ENERCALC Engineering Software Description 6 3/4 X 27 GLB General Information 6.75x27 Section Name Beam Width Beam Depth Member Type Bm Wt. Added to Loads Load Dur. Factor Beam End Fixity Wood Density 6.750 in 27.000 in GluLam 1.250 Pin -Pin 34.000 pcf Full Length Uniform Loads Center Left Cantilever Right Cantilever Trapezoidal Loads #1 DL © Left DL Right Summary Span= 30.00ft, Beam Width = 6.750in x Depth = 27.in, Ends are Pin -Pin Max Stress Ratio 0 1 Maximum Moment 151.6 k -ft Allowable 176.6 k -ft Max. Positive Moment Max. Negative Moment Max © Left Support Max @ Right Support Max. M allow fb 2,218.71 psi Fb 2,583.76 psi Deflections Center Span... Deflection ...Location ...Length /Defl Camber ( using 1.5 * D. @ Center @ Left @ Right Stress Calcs Bending Analysis Ck 19.865 Cv 0.866 @ Center @ Left Support @ Right Support Shear Analysis Design Shear Area Required Fv: Allowable Bearing @ Supports Max. Left Reaction Max. Right Reaction Dead Load -0.427 in 15.000 ft 843.6 L.Defl) 0.640 in 0.000 in 0.000 in Le Rb DL DL DL 221.20 #/ft 221.20 # /ft 423.00 #/ft #/ft #/ft LL Left LL @ Right 151.64 k -ft 0.00 k -ft 0.00 k -ft 0.00 k -ft 176.58 fv 142.42 psi Fv General Timber Beam Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined 300.00 psi Center Span Left Cantilever Right Cantilever Douglas Fir, 24F - V4 Fb Base Allow Fv Allow Fc Allow E at 15.000 ft at 0.000 ft LL LL LL Scope : Reactions... Left DL Right DL 5.498 ft 6.254 Max Moment 151.64 k -ft 0.00 k -ft 0.00 k -ft Left Support 25.94 k 86.479 in2 300.00 psi 20.44 k 20.21 k Total Load -1.233 in 15.000 ft 292.05 Sxx 820.125 in3 CI 0.995 Sxx Req'd 704.25 in3 0.00 in3 0.00 in3 Right Support 25.96 k 86.519 in2 300.00 psi Title : SOUTH CENTER RETAIL Job # 88-067007 Dsgnr: NA Date: 9:45AM, 28 AUG 08 Description : REPLACING TWO MECHANICAL UNITS 881.30 #/ft #/ft #/ft #/ft #/ft 30.00 ft ft ft 2,400.0 psi 240.0 psi 650.0 psi 1,800.0 ksi Maximum Shear * 1.5 Allowable Shear: 7.22 k 6.99 k Left Cantilever... Deflection ...Length/Defl Right Cantilever... Deflection ...Length/Defl Lu Lu Lu Start Loc End Loc 26.0 k 54.7 k @ Left 20.44 k @ Right 20.21 k Camber: @ Left 0.000 in @ Center 0.640 in @ Right 0.000 in Dead Load Total Load 0.000 in 0.000 in 0.0 0.0 Bearing Length Req'd Bearing Length Req'd Area 182.250 in2 Allowable fb 2,583.76 psi 2,596.88 psi 2,596.88 psi 4.658 in 4.607 in 2.67 ft 0.00 ft 0.00 ft 0.000 ft 1.042 ft Page 1 southctr -reta i I.ecw: Calculations Beam Design OK Max 20.44 k Max 20.21 k 0.000 in 0.000 in 0.0 0.0 5 m 15 • Rev. 580004 User. KW -0606898, Ver 5.8.0, 1- Dec -2003 (c)1983 -2003 ENERCALC Engmeenng Software Description 6 3/4 X 27 GLB General Timber Beam M, V, & D @ Specified Locations Center Span Location = Right Cant. Location = Left Cant. Location = 0.00 ft 0.00 ft 0.00 ft Moment 0.00 k -ft 0.00 k -ft 0.00 k -ft Title : SOUTH CENTER RETAIL Job # 88-067007 Dsgnr: NA Date: 9:45AM, 28 AUG 08 Description : REPLACING TWO MECHANICAL UNITS Scope : Shear 20.44 k 0.00 k 0.00 k Page 2 southctr -reta d. ecw:Calculanons Deflection 0.0000 in 0.0000 in 0.0000 in (i o IS • • 1304 -30 #ift llldffillffiffiffiffiffiffiffiffiffikilffil1 1304-30" 221.20 #!ft 1 1 221.20 #/ft 4 30.00 ft Mmax = 151.63 k -ft Dmax = - 1.2326 in Rmax = 20.436 k Rmax = 20.213 k Vmax( left = 20.436k Vmax@a rt = 20.213k of 15 Rev: 580004 User. KW -0606898, Ver 5.8.0, 1 -Dec -2003 (c)19832003 ENERCALC Engineering Software Description 6 3/4 X 24 GLB General Information Section Name Beam Width Beam Depth Member Type Bm Wt. Added to Loads Load Dur. Factor Beam End Fixity Wood Density Full Length Uniform Loads Center Left Cantilever Right Cantilever Trapezoidal Loads #1 DL @ Left DL @ Right @ Center @ Left Support © Right Support Shear Analysis Design Shear Area Required Fv: Allowable Bearing @ Supports Max. Left Reaction Max. Right Reaction 8.75x24 Max Stress Ratio Maximum Moment Allowable Max. Positive Moment Max. Negative Moment Max @ Left Support Max @ Right Support Max. M allow fb 2,392.29 psi Fb 2,643.38 psi Deflections Center Span... Deflection ...Location ...Length /Defl Camber ( using 1.5 * D.L. D @ Center @ Left @ Right [ Stress Calcs Bending Analysis Ck 19.865 Le Cv 0.885 Rb DL DL DL 6.750 in 24.000 in GluLam 1.250 Pin -Pin 34.000 pcf 184.40 #/ft 184.40 #/ft Dead Load -0.454 in 13.608 ft 714.4 efl) ... 0.680 in 0.000 in 0.000 in 5.498 ft 5.896 Max Moment 129.18 k -ft 0.00 k -ft 0.00 k -ft @ Left Support 24.03 k 80.097 in2 300.00 psi 18.63 k 18.92 k Code Ref: 1997/2001 NOS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined 423.00 #/ft #/ft #/ft LL @ Left LL @ Right Summary Span= 27.00ft, Beam Width = 6.750in x Depth = 24.in, Ends are Pin -Pin 0.905 : 1 129.2 k -ft 142.7 k -ft 129.18 k -ft 0.00 k -ft 0.00 k -ft 0.00 k -ft 142.74 fv 151.00 psi Fv 300.00 psi General Timber Beam Center Span Left Cantilever Right Cantilever Douglas Fir, 24F - V4 Fb Base Allow 2,400.0 psi Fv Allow 240.0 psi Fc Allow 650.0 psi E 1,800.0 ksi at 13.716 ft at 0.000 ft Total Load -1.206 in 13.500 ft 268.57 LL LL LL Reactions... Left DL Right DL Title : SOUTH CENTER RETAIL Job # 88-067007 Dsgnr: NA Date: 2:17PM, 1 SEP 08 Description : REPLACING TWO MECHANICAL UNITS Scope : Sxx 648.000 in3 CI 0.995 Sxx Req'd 586.45 in3 0.00 in3 0.00 in3 @ Right Support 24.46 k 81.540 in2 300.00 psi #/ft #/ft Left Cantilever... Deflection ...Length /Defl Right Cantilever... Deflection ...Length /Defl Bearing Length Req'd Bearing Length Req'd 27.00 ft Lu ft Lu ft Lu 881.30 #/ft #/ft #/ft Start Loc End Loc Area 162.000 in2 Allowable fb 2,643.38 psi 2,655.48 psi 2,655.48 psi 12.980 ft 20.021 ft Page soulhcV-retail.ecw:Calculations ns 2.67 ft 0.00 ft 0.00 ft Beam Design OK Maximum Shear * 1.5 24.5 k Allowable 48.6 k Shear: @ Left 18.63 k @ Right 18.92 k Camber: @ Left 0.000 in @ Center 0.680 in @ Right 0.000 in 6.73 k Max 18.63 k 7.02 k Max 18.92 k Dead Load Total Load 0.000 in 0.000 in 0.0 0.0 0.000 in 0.000 in 0.0 0.0 $ or- 15 4.246 in 4.312 in • Rev: 580004 User. KW -0606898, Ver 5.8.0, 1 -Dec -2003 (c)1983 -2003 ENERCALC Engineering Software Description 6 3/4 X 24 GLB Query Values M, V, & D @ Specified Locations © Center Span Location = @ Right Cant. Location = @ Left Cant. Location = 0.00 ft 0.00 ft 0.00 ft Scope : General Timber Beam of IS Moment 0.00 k -ft 0.00 k -ft 0.00 k -ft Title : SOUTH CENTER RETAIL Job # 88-067007 Dsgnr: NA Date: 2:17PM, 1 SEP 08 Description : REPLACING TWO MECHANICAL UNITS Page 2 southctr - retail. ecw:Calculations Shear 18.63 k 0.00 k 0.00 k Deflection 0.0000 in 0.0000 in 0.0000 in • • m3" w i, i; i; ni .i:iu;u 1 _ -7,k x� iI ? i'.:.,_l..L ... �i_N �Aa {: 1 '- i Rmax = 18.629 k Vmax I§ left = 18.629 k ^ ^ IiII.IlilII;I ^^ ^ ^- 27.00 ft Mmax = 129.18 k -ft Dmax = - 1.2063 in Rmax = 18.917 k Vmax R= 18.917k 10 of 15 E N\ T ENGINEERS NORTHWEST, INC., P.S. — STRUCTURAL ENGINEERS PROJECT # SUBJECT ( 67,00 - 007 - (a x 31 Vz. GLB tiN0L - (I2 P O5 -2 s') w : (25 Ps c) 3S, 25') PROJECT 50�7 CTE, ETA IL. 6869 WOODLAWN AVE. N. E., #205, SEATTLE, WA 98115 (206) 5257560 FAX (206) 522-6698 N to llk G -13 \N (T L\? ELF <E,.25 (mac 19,`1 ic. 47 TPiS ' i iprr1 35..25 3G)' -0" { 1 DATE c{ 111200 SHEET 11 OF 15 BY N Rev: 580004 User: KW- 0606898, Ver 5.8.0, 1-Dec -2003 (c)1983 -2003 ENERCALC Engineering Software Description General Information Full Len Center Left Cantilever Right Cantilever Point Loads Dead Load 20,436.0 Ibs Live Load Ibs ...distance 42.000 ft Summary Max Stress Ratio Maximum Moment Allowable Max. Positive Moment Max. Negative Moment Max @ Left Support Max @ Right Support Max. M allow fb 1,580.22 psi Fb 2,495.53 psi Deflections Center Span. Deflection ...Location ...Length /Deft Camber ( using 1.5 * D. @ Center @ Left @ Right 6.75x31.5 GLB Section Name 6.75)(31.5 Beam Width 6.750 in Beam Depth 31.500 in Member Type GluLam Bm Wt. Added to Loads Load Dur. Factor Beam End Fixity Wood Density th Uniform Loads DL DL DL 1.250 Pin -Pin 34.000 pcf 18,917.0 Ibs lbs -6.000 ft Dead Load 0.587 in 18.289 ft 735.5 L. Defl ) ... 0.881 in 0.795 in 0.832 in Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined 423.00 #/ft 423.00 #/ft 423.00 #/ft Center Span Left Cantilever Right Cantilever Douglas Fir, 24F - V8 Fb Base Allow 2,400.0 psi Fv Allow 240.0 psi Fc Allow 650.0 psi E 1,700.0 ksi Ibs Ibs 0.000 ft Scope General Timber Beam LL LL LL Span= 36.00ft, Left Cant= 6.00ft, Right Cant= 6.00ft, Beam Width = 6.750in x Depth = 31.5in, Ends are Pin -Pin 0.633 : 1 -147.0 k -ft 232.1 k -ft 92.87 k -ft at - 131.13 k -ft at - 137.88 k -ft - 147.00 k -ft 232.14 fv Fv 177.46 psi 300.00 psi 17.904 ft Total Load -0.527 in 17.904 ft 819.57 36.000 ft Reactions... Left DL Right DL Title : SOUTH CENTER RETAIL Job # 88-067007 Dsgnr: NA Date: 2:39PM, 1 SEP 08 Description : REPLACING TWO MECHANICAL UNITS Ibs Ibs 0.000 ft 36.00 ft Lu 6.00ft Lu 6.00ft Lu 881.30 #/ft 881.30 #/ft 881.30 #/ft Maximum Shear * 1.5 Allowable Shear: 30.02 k Left Cantilever... Deflection ...Length /Defl Right Cantilever... Deflection ...Length /Defl Ibs Ibs 0.000 ft Ibs Ibs 0.000 ft Page 1 southctr-retail.ecw:Calculations 2.67 ft 2.67 ft 2.67 ft Beam Design OK 37.7 k 63.8 k @ Left 26.78 k @ Right 28.30 k Camber: @ Left 0.795 in @ Center 0.881 in @ Right 0.832 in 32.05 k Max 51.61 k Max 53.64 k Ibs Ibs 0.000 ft Dead Load Total Load -0.530 in -0.636 in 271.6 226.4 -0.555 in -0.658 in 259.5 219.0 12. of 15 • Rev: 580004 User. KW -0606898, Ver 5.8.0, 1- Dec-2003 (c)1983 -2003 ENERCALC Engineering Software Description Stress Calcs Bending Analysis Ck 19.306 Cv 0.837 @ Center @ Left Support @ Right Support Shear Analysis Design Shear Area Required Fv: Allowable Bearing @ Supports Max. Left Reaction Max. Right Reaction 6.75x31.5 GLB Le Rb Query Values M, V, & D @ Specified Locations @ Center Span Location = @ Right Cant. Location = @ Left Cant. Location = 5.498 ft 6.755 Max Moment 131.13 k -ft 137.88 k -ft 147.00 k -ft @ Left Support 35.45 k 118.180 in2 300.00 psi 51.61 k 53.64 k 0.00 ft 0.00 ft 0.00 ft Scope : General Timber Beam Sxx 1,116.281 in3 Area 212.625 in2 CI 0.994 Sxx Read 630.57 in3 663.02 in3 706.85 in3 @ Right Support 37.73 k 125.775 in2 300.00 psi Bearing Length Req'd Bearing Length Req'd Moment - 137.88 k -ft - 137.88 k -ft - 137.88 k -ft Title : SOUTH CENTER RETAIL Job # 88-067007 Dsgnr: NA Date: 2:39PM, 1 SEP 08 Description : REPLACING TWO MECHANICAL UNITS Allowable ft) 2,495.53 psi 2,495.53 psi 2,495.53 psi 11.764 in 12.225 in Shear 24.13 k 24.13 k 24.13 k 13 of 15 Page 2 southctr- retail.ecw: Calculations Deflection 0.0000 in 0.0000 in 0.0000 in • 18917.0 Ibs 20436. O Ibs . I .II ^_^ � I 1I ,3°4 n- 6.00 ft 36.00 ft 1304.30#/ft 1111 l l 130430 Mmax = 131.13 k -ft Dmax = - 0.5271 in Mmax cQ left = - 137.88 k -ft Mmax ® right = - 146.99 k -ft Rmax= 51.612k Rmax= 53.637k Vmax © left = 26.781 k Vmax @ rt = 28.300 k Defl © left end = 0.6359 in Defl @ right end = 0.6576 in 14 OP 15 6.00 ft • ENW ENGINEERS NORTHWEST, INC., P.S. — STRUCTURAL ENGINEERS PROJECT # q 6 1- PROJECT CIE YYL SUBJECT - c LA E-cl,c_ (8E.MAvcc ; I8,12 14- PIST7N6- co NA/c 6869 WOODLAWN AVE. N. E., #205, SEATTLE, WA 98115 (206) 525-7560 FAX (206) 522-6698 0,46 t..:57 .0. (S i 0,6 clAocie_ 0 _ 7( /' orYr" , 07(9 (t_) c - DATE SHEET By 15 OF 15 \S . .5 . /5/-7 , Cv 1 t , Ell r›<1 Cooling Equipment Schedule Equip. ID Brand Name' Model No.' Capacity Btu/h Total CFM OSA CFM or Econo? SEER or EER IPLV Location RTU -1 AMERICAN STANDARD YSC102E 102070 3400 680 11.2EER 121500 ROOF RTU -2 AMERICAN STANDARD YSC120E 118000 4000 800 10.6EER 162000 ROOF x60492 M O 822 S PERM!! VtIV I t Heating Equipment Schedule Equip. ID Brand Name' Model No.' Capacity Btu/h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency RTU -1 AMERICAN STANDARD YSC102E 121500 3400 680 150000 121500 81.000 RTU -2 AMERICAN STANDARD YSC120E 162000 4000 800 200000 162000 81.000 x60492 M O 822 S PERM!! VtIV I t Fan Equipment Schedule Equip. ID Brand Name' Model No.' CFM SP' HP /BHP Flow Control Location of Service EF-1,2 BROAN QTR110 90 0.20 71W Applicant Name: BATHROOMS � �� Applicant Address: 727 S Kenyon St. RECE E 206 - 763 -1744 ��� �� x60492 M O 822 S PERM!! VtIV I t Project Info Project Address souht Center Retail Suite 101 and 105 Date 9/9/2008 16901 Southcentar Parkway For Building Dept. Use t"^ Tukwila, WA Applicant Name: Evergreen Refrigeration � �� Applicant Address: 727 S Kenyon St. Applicant Phone: 206 - 763 -1744 ��� �� Mechanical• Summary 1 I MECH -SUM 2006 Washington State Nonresidential Energy Code Compliance Forms Project Description Briefly describe mechanical system type and features. ❑ Includes Plans Compliance Option 2006 Washington State Nonresidential Energy Code Compliance Form Install (2) rooftop packaged HVAC units,and ( r r... Include documentation requiring compliance with bommissioning req rements,SEon11 B6.2GG8 Simple System 0 Complex System 0 Systems An ysis c (See Decision Flowchart (over) for qualifications. Use separate MEC - SUtfort Revised July 2007 Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. 'If available. 2 As tested according to Table 14 -1A through 14 -1G. 3 If required. ° COP, HSPF, Combustion Efficiency, or AFUE, as • 11 a vaIIaulc. na icaicu awtlla "gmbipf(W stitg. 'lgorwid-riso ,^." ('n '� °�Y' aif,tiaii,tirif n1 uI /IF as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). System Description See Section 1421 for full description of Simple System qualifications. If Heating/Cooling or Cooling Only: ❑ Constant vol? ❑ Split system? ❑ Air cooled? ./ Packaged sys? ❑ <20,000 Btuh? ❑ Economizer included? If Heating Only: 9 Y <5000 cfm . ❑ cfm? <70 /o outside air? ❑ <70% • Mechanical Summary (back) I MECH -SUM Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. Simple System Allowed (section 1420) otal Ca.. wo economize <240,000 Btuh or 10 %? Heating Only 2006 Washington State Nonresidential Energy Code Compliance Form Reference Section 1421 Heating/Cooling or Cooling Only Reference \ Section 1423, Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. Mechanical Permit Plans 2008 Washington State Nonresidential Energy Code Compliance Forms Checklist ' MECH -CI1K Revised July 2007 Project Address Souht Center Retail Suite 101 and 105 !Date 9/9/2008 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability Code I I Required on Plans Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency Mi 1411.1 Combustion htg. Indicate intermittent ignition, flue/draft damper & jacket loss 1412 HVAC controls 1412.1 Temperature zones Indicate locations on plans Mi 1412.2 Deadband control Indicate 5 degree deadband minimum Mi 1412.3 Humidity control Indicate humidistat 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types Mi 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage Mi 1412.4.2 Optimum Start Indicate optimum start controls 1412.5 Heat pump control Indicate microprocessor on thermostat schedule 1412.6 Combustion htg. Indicate modulating or staged control 1412.7 Balancing Indicate balancing features on plans Mi 1412.8 Ventilation Control Indicate demand control ventilation for high - occupancy areas 1422 Thermostat interlock Indicate thermostat interlock on plans 1423 Economizers Equipment schedule 1413 Air economizers 1413.1 Air Econo Operation Indicate 100% capability on schedule 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb 1413.2 Water Econo Doc Indicate clg load & water.econoe & clg tower performance 1413.3 Integrated operation Indicate capability for partial cooling 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems 1414.1 Duct sealing Indicate sealing necessary Mi 1414.2 Duct insulation Indicate R -value of insulation on duct Mi 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Completion Requirements 1416.2.1 Commissioning Provide commissioning plan 1416.2.2 -3 Sys.Bal & Func.Test Indicate air and water system balancing & functional testing 1416.2.4 Commissioning Indicate O &M manuals, record drawings, staff training 1416.2.5 Comm. Report Indicate requirements for prelim. & final commissioning report Mi 1434 Separate air sys. Indicate separate systems on plans Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer Mi SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. 1441 Elec. water heater Indicate R -10 insulation under tank 1442 Shut -off controls Indicate automatic shut -off 1443 Pipe Insulation Indicate R -value of insulation on piping 1452 Heat Pump COP Indicate minimum COP of 4.0 1452 Heater Efficiency Indicate pool heater efficiency 1453 Pool heater controls Indicate switch and 65 degree control 1454 Pool covers Indicate vapor retardant cover 1454 Pools 90+ degrees Indicate R -12 pool cover 2006 Washington State Nonresidential Energy Code Compliance Form • • • 2006 Washington State Nonresidential Energy Code Compliance Form ` If "no" is circled for any question, provide explanation: 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Permit Plans Checklist MECH-CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified 4 . 1 ting conditions not less than the values shown in Table 14-1A through 14 -1G. If a ationally recognized certification program exists for a product covered in Tables 14-1A through 14-1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings 225,000 Btu/h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings > 225,000 Btu/h (65 kW), including electric fumaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be fumished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Coo ing Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu/h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a iii uilding shall be considered as a separate zone. 12.2 Deadband Controls: When used to control both comfort heating and ooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or altemate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual off-hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief enings shall be equipped with normally open (fails to open upon loss of power) mpers. These dampers shall remain closed until activated by the fire alarm stem or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings 1412.8 Ventilation Controls for High - Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu/h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246- 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu/h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, EF CAE < 50 gal storage 0.58 0.71 50 to 70 gal storage 0.57 0.71 > 70 gal storage 0.55 0.70 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Permit Plans Checklist MECH-CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified 4 . 1 ting conditions not less than the values shown in Table 14-1A through 14 -1G. If a ationally recognized certification program exists for a product covered in Tables 14-1A through 14-1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings 225,000 Btu/h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings > 225,000 Btu/h (65 kW), including electric fumaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be fumished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Coo ing Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu/h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a iii uilding shall be considered as a separate zone. 12.2 Deadband Controls: When used to control both comfort heating and ooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or altemate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual off-hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief enings shall be equipped with normally open (fails to open upon loss of power) mpers. These dampers shall remain closed until activated by the fire alarm stem or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings 1412.8 Ventilation Controls for High - Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu/h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246- 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu/h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, „ ,a.,,, „,29, INAMV gg,$14tg,N411 gjOpnti.al.Energy.Code Campliance.Farm -- - , -... _.__. _ ... -. - -. -. -- -. outlets in the first story and levels below the first story of buildings duct runs are considered building envelope until they, . three or more stories in height. 1. connect to the heating or cooling equipment, or 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply 2. are isolated from the exterior with an automatic shut -off damper complying air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum with Section 1412.4.1. start controls shall be designed to automatically adjust the start time of an HVAC Once outside air ducts meet the above listed requirements, any runs within system each day to bring the space to desired occupied temperature levels conditioned space shall comply with Table 14 -5 requirements. mediately before scheduled occupancy. The control algorithm shall, as a Other ducts and plenums shall be thermally insulated per Table 14 -5. inimum, be a function of the difference between space temperature and occupied Exceptions: etpoint and the amount of time prior to scheduled occupancy. 1. Within the HVAC equipment. 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start-up, set 2. Exhaust air ducts not subject to condensation. up, and defrost conditions. These controls shall anticipate need for heat and use 3. Exposed ductwork within a zone that serves that zone. compression heating as the first stage of heat. Controls shall indicate when 1415 Piping Systems supplemental heating is being used through visual means (e.g., LED indicators). 1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14 -6. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment Exception: Piping installed within unitary HVAC equipment. with a capacity over 225,000 Btu/h shall have modulating or staged combustion Water pipes outside the conditioned space shall be insulated in accordance with control. 000 Washington State Plumbing Code (WAC 51 -26) EXCEPTIONS: 1. Boilers. 2. Radiant heaters. 1416 Completion Requirements (Refer to NREC Section 1416 and the Building 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have Commissioning Guidelines, published by the Building Commissioning Association, a means for balancing, including but not limited to, dampers, temperature and for complete text and guidelines for building completion and commissioning pressure test connections and balancing valves. requirements.) • 03 -02 -2008 KEO TORRE 727 S KENYON ST SEATTLE WA 98108 RE: Permit No. M08 -225 16901 SOUTHCENTER PY TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 04/29/2009 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, J f r Marshall, Pe Technician xc: Permit File No. M08 -225 Jim Haggerton, Mayor epartment of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206 - 431 -3665 ACTIVITY NUMBER: M08 -225 DATE: 09 -09 -08 PROJECT NAME: MATTRESS DEPOT SITE ADDRESS: 16901 SOUTHCENTER PY SUITE 101 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: BlJl .'' g ISl Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete TUES/THURS ROUTING: Please Route Documents/routing slip.doc 2 -28 -02 • PERMIT C ORD COPY PLAN REVIEW /ROUTING SLIP C REVIEWER'S INITIALS: S'u u/ q Fire Prevention Structural Incomplete APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Structural Review Required n Planning Division n Permit Coordinator DUE DATE: 09 -11 -08 Comments: Permit Center; Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: No further Review Required DATE: DUE DATE: 10-09-08 Not Approved (attach comments) n DATE: Not Applicable n Perniit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 TRAVELERS CAS Et SURETY CO 104667361 01/01/2006 Until Cancelled 01/06/2006 $12,000.00 01/03/2006 Name Role Effective Date Expiration Date EVERGREEN REFRIGERATION LLC PARTNER /MEMBER 12/22/2005 Amount PATTON, DAVID PARTNER /MEMBER 01/06/2006 PATTON, RODGER PARTNER /MEMBER 01/06/2006 PATTON, MATTHEW PARTNER /MEMBER 01/06/2006 Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date CONTINENTAL Untitled Page General /Specialty Contractor A business registered as a construction contractor with LEtI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company EVERGREEN REFRIGERATION LLC 2067631744 727 S KENYON ST SEATTLE WA 98108 KING LIMITED LIABILITY COMPANY UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 602512953 ACTIVE EVERGRL954R2 CONSTRUCTION CONTRACTOR 1/6/2006 1/6/2010 EVERGI "201 D7 GENERAL UNUSED Business Owner Information Bond Information Insurance Information • Page 1 of 2 https: / /fortress.wa. gov /lni/bbip/Detail. aspx ?License= EVERGRL954R2 09/19/2008 SYMBOL LEGEND SYMBOL ABBY. DESCRIPTION K. AIRFLOW CFM DUCT SECTION SUPPLY r MOTOR HP DUCT SECTION - RETURN /EXHAUST COOLING HEATING RECTANGULAR DUCT y TOTAL TOTAL SEER ROUND DUCT INPUT OUTPUT AI =LIE FLEXIBLE DUCT 1 _ _ MVD MANUAL VOLUME DAMPER UNIT BDD BDD BACKDRAFT DAMPER © MD MOTORIZED DAMPER FD FIRE DAMPER 4 _....___o FSD FIRE /SMOKE DAMPER (120V POWER REQ.) --K4 BTUH CEILING RADIATION DAMPER so SD SMOKE DETECTOR 0 T THERMOSTAT ® s SENSOR -- Ft -- - - - R R REFRIGERANT LINES - -C-- - - - G G NATURAL GAS LINES 680 01. #1 102,070 CEILING DIFFUSER (SUPPLY) 11.2 pa 121,500 81% CEILING DIFFUSER (RETURN /EXHAUST) 30 21.9 EXHAUST FAN (CEILING MOUNTED) 945 IFI 115 1096 INLINE FAN II1/E RECEIVED PROPELLER FAN icP O 9 Egn SIDEWALL DIFFUSER PERMIT CENTER AMERICAN STANDARD IIII ��/��(,,,I 10 _ i f 0.5" 800 1 fI #1 DUCT FITTING - -- B.O.J. 12' 2 200,000 DATUM 81% 0 30 UNIT TAG 35 Q 36 DUCT RISER PACKAGED HEAT PUMP EQUIPMENT SCHEDULE MARK MANE. MODEL TONS. AIRFLOW CFM SP INS MIN. OSA CFM MOTOR HP DRIVE # COOLING HEATING ELECTRICAL WEIGHT TOTAL TOTAL SEER EER INPUT OUTPUT AI =LIE VOLTS PHASE M.C.A. MOP UNIT ECON CURB WEIGHT BTUH BTUH BTUH V (A) (A) LBS LBS LBS LBS RTU 1 AMERICAN STANDARD YSC102E 8.5 3,400 0.5" 680 2 #1 102,070 - -- 11.2 150,000 121,500 81% 460 30 21.9 25 945 36 115 1096 RTU 2 AMERICAN STANDARD YSC120E 10 4,000 0.5" 800 3 #1 118,000 - -- 10.6 200,000 162,000 81% 460 30 26.5 35 1050 36 115 1201 EXHAUST FAN SCHEDULE MARK MANE. MODEL CFM S.P. VOLTS PHASE Hp/A NOTES EF 1,2 BROAN QTR110 90 0.2" 115 1 71 W LOCATED ON CEILING RT 1 8.5 TO 6b s OCCUPANT LOAD 10 TON I.-EX T CFM (TYP 1 GENERAL NOTES VICINITY MAP SCALE UGC: ropy Permit No mar review approval is subject to errors and cm #^g,;r Approval of construction documents does not author :co the violation of any adopted code or ord na !cc. t C' of approved Fiolr Copy and conditions is ackno it&is d: By Date: City of Tukwila BUILDING DIVISION 0 e c 97aiil c aI I� ��10�:1rir✓�,I yiumbing Iol Gas Piping 72y Itt n m ^tr�n .rl hr�IS ?!I oIlflQ [1 T'1_'f"ii 'nS will rrluim 1 nail/ r* RbV1t'VED FOR ¢ CODE COMPLIANCE APPROVE SEP 1 8 2 `i Of ukwi1a gUT ING HVAC FLOOR PLAN SCALE : 1/8" = 1' -4" COMPLETION AND COMMISSIONING FOR MECHANICAL SYSTEMS RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER WA ENERGY CODE (WSEC) SECTION 1416.1. AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER PER WSEC SECTION 1416.2.4.1 ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCE REPORT SHALL BE PROVIDED TO THE OWNER PER WSEC SECTION 14516.2.2.1. FOR WAREHOUSES SEMIHEATED SPACES AND SIMPLE SYSTEMS (AS DEFINED IN WSEC SECTION 1421): HVAC CONTROL SYSTEMS SHALL BE TESTED, CALIBRATED AND ADJUSTED, SEQUENCES OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORD WITH SPECIFICATIONS AND APPROVED PLANS, AND A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE FILED WITH THE OWNER PER WSEC SECTION 1416.2.3.2. FOR ALL OTHER SYSTEMS: HVAC CONTROL SYSTEMS SHALL BE TESTED, CALIBRATED AND ADJUSTED, SEQUENCES OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORD WITH SPECIFICATIONS AND APPROVED PLANS PER WSEC SECTION 1416.2.3.2; NECESSARY TESTS SHALL BE IDENTIFIED PER WSEC SECTION 1416.2.3; A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED PRIORO TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY PER WSEC SECTION - 1416.2.5.1 AND A COMPLETE FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE FILED WITH THE OWNER PER WSEC SECTION 1416.2.5.2. 8" UP DUCTWORK NOT PUBLISHED. ALL RIGHTS RESERVED. THE DRAWING AND SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF EVE- RGREEN REFRIGERATION INC. NO PART THEREOF SHALL BE REPRODUCED, COPIED, ADAPTED. DISC- LOSED OR DISIRIBUTED TO OTHERS, SOLD, PUB- LISHED OR OTHERWISE USED WITHOUT THE PRIOR WRITTEN CONSENT OF AND APPROPRIATE COMPEN- SATION TO EVERGREEN REFRIGERATION INC. VISUAL CONTACT WITH THE ABOVE DRAWINGS OR SPECIFIC- ATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. CO C, Q 0 LU 0 V) Ca z ck 0 W 0 • El El El LO G 06 w w z w 0 0 REVISIONS NO DATE DRAWING DATE: SHEET: M ITEM 09/03/08 DWG. BY: GN CHK. BY: RB JOB NO.: 58019 DWG. FILE: 58019M1 1.1 ALL DUCT DIMENSIONS ON PLAN ARE CLEAR INSIDE DIMENSIONS, ADD 2" TO EACH DIMENSION TO OBTAIN OUTSIDE DIMENSION. ADD 4 "TO EACH DIMENSION IF DUCTWORK IS ON THE EXTERIOR OF BUILDING. 1.2 THE FIRST NUMBER ON ALL DUCT DIMENSIONS IS THE WIDTH AND THE SECOND NUMBER IS THE HEIGHT. 1.3 MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT RATING LESS THAN 50, PER IMC 602.2.1. 1.4 SEAL ALL TRANSVERSE JOINTS FOR DUCTWORK WITH STATIC PRESSURE BETWEEN 1/2 INCHES AND 2 INCHES. DUCTWORK WHICH IS DESIGNED TO OPERATE AT PRESSURES ABOVE 1/2 INCH WATER COLUMN STATIC PRESSURE SHALL BE SEALED IN ACCORDANCE WITH STANDARD RS -7. 1.5 ALL DUCT GAUGES PER SMACNA, IMC 603-4. 1.6 ALL DUCT SUPPORTS PER SMACNA, IMC 603 -10. 1.7 ATTACH D'FFUSERS AND GRILLES TO T -BAR GRID PER WA STATE & LOCAL CODES. 1.8 BALANCING DAMPERS ARE TO BE INSTALLED ON ALL BRANCH DUCTS OR DIFFUSERS. INSULATION 2.1 INSULATE OR LINE DUCTWORK PER WA. STATE ENERGY AND MECHANICAL CODES. 2.2 INSULATE REFRIGERANT & CONDENSATE PIPING PER STATE & LOCAL ENERGY CODES. GENERAL CONTRACTOR 3.1 GENERAL CONTRACTOR TO PROVIDE AND CUT OPENINGS FOR ALL ROOFTOP, CEILING, FLOOR, AND WALL PENETRATIONS, INCLUDING WEATHERPROOF SEALING AND FIRE PROOF LINING PER IMC & IBC. 3.2 GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATION AND DIMENSIONS WITH ERL BEFORE FRAMING OPENINGS. 3.3 GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING, AND PAINTING AS REQUIRED FOR MECHANICAL WORK. 3.4 GENERAL CONTRACTOR TO PROVIDE ADEQUATE STRUCTURAL SUPPORT AS REQUIRED FOR MECHANICAL WORK. 3.5 GENERAL CONTRACTOR TO PROVIDE ADEQUATE ENGINEERING AS REQUIRED FOR MECHANICAL WORK. 3.6 GENERAL CONTRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL MECHANICAL EQUIPMENT. 3.7 GENERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY ERL PROVIDE ALL CANT ;STRIPS AND CURB INSULATION, AND SEAL AGAINST LEAKS. 3.8 GENERAL CONTRACTOR TO PROVIDE ALL CUTTING AND PATCHING OF T -BAR CEILING AS REQUIRED FOR HVAC INSTALLATION. 3.9 GENERAL CONTRACTOR TO PROTECT ALL OPENINGS THROUGH FLOORS PROVIDED FOR DUCTWORK INSTALLATION IN ACCORDANCE WITH TABLE 601 OF INTERNATIONAL BUILDING CODE, WHERE REQUIRED BY SECTION 707 OF IBC. ELECTRICAL 4.1 ERL TO INSTALL ALL LOW VOLTAGE CONTROL WIRING, CONDUIT WILL BE PROVIDED BY ELECTRICAL CONTRACTOR. 4.2 ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL CONNECTIONS, DISCONNECTS, AND STARTERS FOR MECHANICAL EQUIPMENT. 4.3 ELECTRICAL CONTRACTOR TO VERIFY EQUIPMENT SIZES, LOADS AND LOCATIONS WITH ERL MECHANICAL PLAN AND WITH FIELD CONDITIONS. 4.4 ELECTRICAL CONTRACTOR TO INTERLOCK BATHROOM EXHAUST FANS WITH LIGHT SWITCH. 4.5 ERL TO PROVIDE 7 -DAY NIGHT SETBACK, PROGRAMMABLE TYPE T -STAT WITH CAPABILITY OF 5 °F DEADBAND. 4.6 ERL TO VERIFY FINAL LOCATION OF THERMOSTAT WITH CUSTOMER. 4.7 ELECTRICAL CONTRACTOR TO PROVIDE ELECTRICAL GCFI OUTLET WITHIN 25 FT OF EACH PIECE OF MECHANICAL EQUIPMENT. PLUMBING 5.1 PLUMBING CONTRACTOR TO FURNISH AND INSTALL ALL GAS PIPING FOR MECHANICAL EQUIPMENT PER CODE. 5.2 PLUMBING CONTRACTOR OFFSET VENTS 10 FEET MINIMUM FROM ALL HVAC FRESH AIR INTAKES OR 2' ABOVE HIGHEST POINT OF INTAKE, IMC 401.5.1. 5.3 CONDENSATE DRAINS FROM RTU BY ERI TO DRAIN WITHIN 12" OF UNIT. CONDENSATE DRAINS FOR AIR HANDLERS BY PLUMBER. ENERGY CODE COMPLIANCE 6.1 AT A MINIMUM, EACH FLOOR IS TO BE CONSIDERED A SEPARATE ZONE. VERIFY THERMOSTATIC CONTROL FOR EACH ZONE AS INDICATED ON PLANS. 6.2 OUTSIDE AIR INTAKES, EXHAUST OUTLETS, AND RELIEF OUTLETS SERVING CONDITIONED SPACES SHALL BE EQUIPPED WITH DAMPERS WHICH CLOSE AUTOMATIC' ALLY WHEN THE SYSTEM IS OFF OR UPON POWER FAILURE, PER WSEC SEC. 1412.4.1. 6.3 AIR ECONOiv1IZERS WHERE REQUIRED BY CODE ARE INDICATED BY THE EQUIPMENT SCHEDULE AT 100% CAPABILITY, CONTROL AND OPERATION OF THE ECONOMIZER SHALL COMPLY WITH WSEC SEC. 1423. MECHANICAL CODE COMPLIANCE 7.1 WHERE REQUIRED PROVIDE AUTOMATIC SHUTOFF ACTIVATED BY SMOKE DETECTORS IN EACH SYSTEM DELIVERING HEATING OR COOLING AIR IN EXCESS OF 2000 CFM. DETECTORS SHALL BE LOCATED IN THE MAIN RETURN AIR PER IMC 606. WA2004 #1 1 of 1 SHEETS