Loading...
HomeMy WebLinkAboutPermit M08-226 - VACANT SPACEVACANT SPACE 16901 SOUTHCENTERPY STE 105 M08.-226 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: EVERGREEN REFRIGERATION LLC Address: 727 S KENYON ST , SEATTLE WA Contractor License No: EVERGRL954R2 DESCRIPTION OF WORK: INSTALL (1) PACKAGE HVAC UNIT, (1) EXHAUST FAN FOR RESTROOM, DUCTWORK .AND DIFFUSERS. Value of Mechanical: $20,000.00 Type of Fire Protection: Furnace: <100K BTU 1 >100K BTU 0 Floor Furnace 0 Suspended/Wall/Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System.... 0 Air Handling Unit <10,000 CFM 0 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 1 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial/Industrial 0 doc: IMC-10/06 Cityif Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us 2623049011 16901 SOUTHCENTER PY TUKW VACANT SPACE 16901 SOUTHCENTER PY , TUKWIILA WA OCM ESCROW ADMINISTRATION 1717 MAIN ST 8TH FL- ESCROW , DALLAS TX 'CEO TORRE 727 KENYON ST , SEATTLE WA MECHANICAL PERMIT EQUIPMENT TYPE AND QUANTITY * * continued on next page ** M08 -226 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 - 763 -1744 Phone: 206 763 -1744 Expiration Date: 01/06/2010 M08 -226 09/19/2008 03/18/2009 Fees Collected: $395.00 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 12 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 09 -19 -2008 Signature: Print Name: doc: IMC -10/06 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Center Authorized Signature: Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this pe t does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the per' of work.) am authorized to sign and obtain this mechanical permit. 5,¢41 4,,9e&So/' Permit Number: M08 -226 Issue Date: 09/19/2008 Permit Expires On: 03/18/2009 Date: ` —( f ° This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M08 -226 Printed: 09 -19 -2008 Parcel No.: 2623049011 Address: 16901 SOUTHCENTER PY TUKW Suite No: Tenant: VACANT SPACE 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: M08 -226 Status: ISSUED Applied Date: 09/09/2008 Issue Date: 09/19/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: ** *FIRE DEPARTMENT CONDITIONS * ** 12: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 13: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 14: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 15: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) doc: Cond -10/06 M08 -226 Printed: 09 -19 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 17: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 18: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 19: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 20: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 21: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 22: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** doc: Cond -10/06 M08 -226 Printed: 09 -19 -2008 Signature: Print Name: S4 PT A/P e09 2 ,50 /t/ doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Date: M08 -226 Printed: 09-19 -2008 Site Address: CITY OF TUKWI Community Developmen ' epartment Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Name: pvLt.. Mailing Address: "1 1 5 - >fi „ /tM Mailing Address: 11-7 S• b•N-'-iivrt S 4 Contact Person: A PP(aC O1 n E -Mail Address: Contractor Registration Number: Company Name: Mailing Address: Contact Person: E -Mail Address: Company Name: Mailing Address: *ontact Person: E -Mail Address: Q:\Applications\Forms- Applications On Line3-2006 - Mechanical Permit Application. doe Revised: 4 -2006 bh MECHANICAL PERMIT APPLICATION Mechanical' Project No. r 11(O- 2L(p m><t No. . .. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** t c, g 0 564t ce ►1 d' Tenant Name: !'AN 4/■ ivc \ )�'q vti�-- S pat C P Property Owners Name: o G " rS G v tr•- i d Nt a n j f 7 Mailing Address: (1 1 1 PIA 41 ci 114 City • , P,�E,,,,,RSONC- who•do ° we t ctintact when your:permit,is resdy'toaie +is §ueci" • : ` R p t ...a } t "X' ^ , .. ;•�.• .. •rr p 't . v7.7 + 317`{ • emu' Cvt:OA ec4,n (+v ffC , ce Mail Address: M :,. ECHANICALONTRAO OR`INFORMA�TION =£ f e y r . . � r a - �' l��w.t+� �a� 1 °; ;,; -fir �'.t - 4a } ' s , rz ? - °d eedX ;"� s- � � ompanyName: 54 et {/!itor LL G VI:t.0 LL 1 ,f Li P-Z King Co Assessor's Tax No.: Suite Number:444f la Day Telephone: so., — i Co 7 — 1 7 4 N City Fax Number: City New Tenant: .... Yes La..No State Zip - 6 — ?' ) - - 3 'I 2&Z 30'1 to 11 T7` State Floor: 104- 47 /c , a LNr' I P/ State Zip Day Telephone: - z'A- — Z lP " � -17 y Fax Number: 7,0( -- 7 ( e 7— Z 7 Expiration Date: ` / r / 1 �,..._ �];. 7n,i ,�:• •' 3^rV i" �Xl'F"' " "sv�.7 � "Ra d4" •' <u.ru:saXrGu :TECT'.OF'RECORD - _ All -clans must :be:wetatamned:bv.•Archetect:of Recor4 -n.. City Day Telephone: Fax Number: State ENGINEER OF RECORD - All'plans. must bewet :stamped by Engineer of Record`• : . City Day Telephone: Fax Number: State Zip Zip Zip Page 1 of 2 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace<100K BTU it I Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser `X.. 1,44 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct 1 1 T hermostat 15 -30 HP /1,000,000 BTU Suspended /Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP/1,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator – Comm/Ind Other Mechanical Equipment Valuation of Project (contractor's bid price): $ � t ' Scope of Work (please provide detailed information): "7--✓1 )4 1 (. ) log GW.tyed itJ - vi - G vn Ifs (Z1 - c1.110 +14-rn cjvC -Fww� 1 yviilkl a 4v • 12eeGti 124- q / Pi M'v c-t , ( -1-111 Q kI i e Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ❑ Replacement .... Fuel Type: Electric ❑ Gas Other: Indicate type of mechanical work being installed and the quantity below: Value of Construction – In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review – Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE : OR AU I� 1 Signature: Print Name: Mailing Address: f Date Application Accepted: `1-1 RIZED AGENT: Q \Appiication,Forms- Applications On Line\3 -2006 - Mechanical Permit Application.doc Revised. 4-2006 bh ce Date Application Expires: Date: R / / Day Telephone: SO. 61-11,411 S S4, l"'- `I Cit State Zip Staff Initials: Page 2 of 2 Parcel No.: 2623049011 Permit Number: M08 -226 Address: 16901 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 09/09/2008 Applicant: VACANT SPACE Issue Date: Receipt No.: R08 - 03194 Initials: WER User ID: 1655 Payee: EVERGREEN REFRIGERATION TRANSACTION LIST: Type Method Descriptio Amount Payment Check 003287 395.00 ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Account Code Current Pmts 000.322.102.00.0 316.00 000/345.830 79.00 Total: $395.00 Payment Amount: $395.00 Payment Date: 09/09/2008 11:26 AM Balance: $0.00 doc: Receiot -06 Printed: 09 -09 -2008 Project: 1 �4ali SPA(' Type of Inspection: y=-("J A r Address 1 6 (Sens- ir+et4.P Date Called: Special Instructions: Date Wanted: 3--5—e) 0. Requester: Phone No 2_,a6 X2.3 r L/ 4 CTION RECORD Retain a copy with permit INSPECT! O. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 COM NTS: ;,.k /.fit fl4 4`" I•�/ .�/ Date: • NSPECTION FEE go RED. Prior to inspection, fee must be 300 Southcenter Blvd.) Suite 100. Call to schedule reinspection. Date: Approved per applicable codes. LJ Corrections required prior to approval. g2U PERMIT NO. (206)431 -3670 .1 • • ,.i, mob...._, . _ 4 \.:5,:,2,,!4 - =-- - x-;41 ProjQ t: V >9 Type of Inion: i 1 N A Address: 1 la C I O 1 c eu +1►4 r Date Called: . Special Instructions: j Date Wanted:' 2. — 3---o 9 p.m. Requester: r. Phone No: _ 2_06-2'3g-231g • • INSPECTION RECORD Retain a copy with permit INSPE ON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ► 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 J Approved per applicable codes. qAr e Corrections required prior to approval.. ■' CO ENTS: 41.4/ — carpi f 4 4.44...., 1 .00 REINSPECTION FEE id at 6300 Southcenter Btv. Date: 1-3 ED. Prior to inspection, fee must be ite 100. Call to schedule reinspection. Rectipt No.: 'Date: COMMENTS: jt-} L/ - . 1 / ?0/0 .. /./ — fl/ ' ) i as �i1", /, :nr/ ` 41, Adie.!9 _ ,...5 / *I o e....e ....5")7/r/— icitAiiV — 4) ,,... /f , , ,, I . P .0 co- 45 A a i iv .6 ri-' I- iili-e f „ c ) /W ? /N, " itveaf ‘,4, -- AlF.0-o c rr ,-/4 h/ - A/�r (4 Special Instructions: /n' f G)/ ?" 49/7 / ? & /7�y Date Wanted: — 2 j — c7 Project: Type of Inspection: Address: /6 9 / / 4'f.A4 t , Date Called: Special Instructions: /n' f G)/ ?" 49/7 / ? & /7�y Date Wanted: — 2 j — c7 P.M. Requester: o: Phone No: c/ INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 14 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. Corrections required prior to approval. Inspector a. Date: 2 4 . 1 5 .00 REINSPECTION F REQUIR i. Prior to inspection, fee must be id at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Project: Ty e of I r_,; a tion: _.. Address: 1 (ALO ( -5 I P J4 Date Cal - : /k._.— Special Instructions: (! 03 141_5 � v r 1. r S SC PAJ l� a Wanted: a.m. `R 7 - (p - © � p:m. Requester: f 6 J m A b eg Phone No: / 234 — INSPECTION RECORD Retain a copy with permit PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING.bIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. EI Corrections required prior to approval. COMMENTS: 4 d' 630L. v D El $60.00 REINSPECTION E REQ IRED. Prior to inspection, fee must be paid at 6300 Southcent Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Jyk COMMENTS: Type of Inspction: c' (7 f `-. t ' i k- L / Address: / t - - , Suite #: Contact Person: , e' t 4_ 1 Special Instructions: 114c; ( 1 - --,- , ;,..)t- L 0 1,:: _4-.47 1 i'• c pt cr Ai 4- '' L (1 iti 64-1 7 Kir ( - C --, e - . ,1 ; i r „ ,.,/ Project: ,... , k , 4 '`.. S *, ! .. , I Type of Inspction: c' (7 f `-. t ' i k- L / Address: / t - - , Suite #: Contact Person: , e' t 4_ 1 Special Instructions: iti Phorie No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre-Fire: Permits: Occupancy Type: INSPECTION NUMBER 2 Appfoved per applicable codes. Word/Inspection Record Form.Doc INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT 1/13/06 PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206-57 ri Corrections required prior to approval. Inspector: Date: ? / H $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 ENW • e get ildings built. STRUCTURAL ENGINEERS Engineers Northwest Inc., P.S. 0 n08 Zz b STRUCTURAL CALCULATIONS FOR R�u"dti NEW MECHANICAL �'Tg AT SOUTH CENTER RETAIL BUILDING 16901 South Center Parkway Tukwila WA 98188 Jose Parada, PE /SE Nawzad Ahmed 'Mid' 3 3/ September 2, 2008 ENW Project No. 88- 067007 CODE: 2006 IBC / ASCE 7 -05 • FP 7,7 CdPV REVIEWED FOR ► CODE COMPLIANCE ' APPROVED SEP 18 2808 CI i Of Tu iia BUILDING DIVISION RECEIVED SEP 09 as PERMIT CENTER • 6869 Woodlawn Avenue NE • Seattle, WA 98115 206.525.7560 • fax 206.522.6698 www.enwseattle.com /o" 0 3� G C,cA'4 x /8 g I (. iz ") < /8' o "� /J L/¢- n5 I /4.col f/4:0 J '3 7'- 0 •I c • /8'- o" r 5 • 3y2 LEAGE/ Co 3 j4 5 /8 ° COX PLYLJ'A, SEE Nore PO e)LOCKING 1 Co 0" Nom I3(0216 "� �•, �0 TON 2Tu) • /¢ . pcc. S Co ` ' Z 7 3 /42' ) [ S 3 • • F. 7 A G . F 81/ UC � J 0 0 �-N L v VP') —0 r rat u r-7 _ ENW • PROJECT # (./7 • SUBJECT LL Dt-- ENGINEERS NORTHWEST, INC., P.S. – STRUCTURAL ENGINEERS PROJECT .�. c.)../T1-i C-7{ , MAu ADD -r ioi I.ZooF 1:7ro w.>5 By NF 6869 WOODLAWN AVE. N. E., #205, SEATTLE, WA 98115 (206) 525 -7560 FAX (206) 522-6698 DATE 7 ( 7:7-1* f< • t yi L _ - C SHEET 2- OF 1 5 — 2,2- ( I ..' 5 /8 " cps rt waa n - 1,0 10S0L T))N --$ 0 TJ L 7 / ,/ 1,0 sgg4Nlk f ■onc - --I■!> I e ce, CEIL—I1,1 fr roTIA L 11 N vS� 1 2 PSF EN\V ENGINEERS NORTHWEST, INC., P.S. - STRUCTURAL ENGINEERS 6869 WOODLAWN AVE. N. E., #205, SEATTLE, WA 98115 (206) 525-7560 FAX (206) 522-6698 PROJECT # F3b0 G PROJECT EOu * DATE 1 71- 1 200 SUBJECT 1 u (n� ��? MD y « ■ 1 ∎ J SHEET ,n 3 OF 15 T11 1 1 / L A D\ H U- BY NIA • o — C - oni BTU as TON ET(A (YSc 12Q €> A : L.-. 11 /" X `3O 1 /6" UNiT Wr, £ooF curzt I3 (02 - G-1 PS5 2c . Sc, if' P.c = 29 ,S CE ci �YSC Iozrr� 1�5-3- Ih y2,S3 P- - c c 120 1 IBS I Lj 'u I V) (R,Rorn 1..\c \o y 2 e t- SC0 C-" 1b V NIT Ali- I oc'I 16 KooF cu2b 1\ Ib [C01JOMIFtz_ 131412s",c.,Emc Io t 6 - 1OT L lb C y 2s (p_c,ci ; �) • • ENW ENGINEERS NORTHWEST, INC., P.S. — STRUCTURAL ENGINEERS 6869 WOODLAWN AVE. �� N. E., #205, SEATTLE, WA 98115 (206) 525-7560 FAx (206) 522-6698 / PROJECT # c1 t� C9� Dof PROJECT SO✓ (-1i FAT rtL DATE Si 20 (2-0° c0 D SUBJECT PLra G&JEZA NOTES (SH LET j( WDL • (0 x 2 4 G a ►.IV^^' MitA GL' LOAD %NG- SIMP1E "RN ', Do°G -LAS "P R. COAST C J '24F \j4 CAN MEM66n ; 2L (bF /ce) (Pb =2iloo Psi) ® (o 3 /4 )( 2 - 7- CTL8 SPP 1J -ow -TRW V11DTH 35.25 ■ (F7.. P4 (35,2S ) _ 423 PLF (2S Pce) ,15 _ . C d131.25 PLF SP Ool = 2 —0 TRIB wiorn = 35.25' (Dq (Ft, =2.400 E&j> SHEET '1 OF 15 BY N(- RTV\ wE \ Cj- A V (46,1 PSF) 4Yg,) - Z.OI -ZI ?LE SP kN - C V2 (c-fom LEFT) vJDL 42P (35,2 = 423 PL WLL . `25 PsF-- � 35.25) _ Sb1,25 Pl- RTU _ (42,25 Ps -4 > i ,L1 i PLF � SPP\I _ 7' —v ' / c rr_ _ C� mt0 sPAN o f �� Rev: 580004 User. KW- 0808898, Ver 5.8.0, 1- Dec -2003 (c)1983 -2003 ENERCALC Engineering Software Description 6 3/4 X 27 GLB General Information Section Name Beam Width Beam Depth Member Type Bm Wt. Added to Loads Load Dur. Factor Beam End Fixity Wood Density Full Length Uniform Loads Center Left Cantilever Right Cantilever 6.75x27 DL DL DL 6.750 in 27.000 in GluLam 1.250 Pin -Pin 34.000 pcf 423.00 #/ft #/ft #/ft Tra ezoidal Loads #1 DL @ Left DL Right Summary 221.20 #/ft 221.20 #/ft LL @ Left LL © Right Span= 30.00ft, Beam Width = 6.750in x Depth = 27.in, Ends are Pin -Pin Max Stress Ratio Maximum Moment Allowable 0.859 : 1 151.6 k -ft 176.6 k -ft at 15.000 ft at 0.000 ft Max. Positive Moment 151.64 k -ft Max. Negative Moment 0.00 k -ft Max @ Left Support 0.00 k -ft Max @ Right Support 0.00 k -ft Max. M allow 176.58 fb 2,218.71 psi fv 142.42 psi Fb 2,583.76 psi Fv 300.00 psi Deflections Center Span... Deflection ...Location ...Length/Deft Camber ( using 1.5' D.L. Defl ) ... @ Center 0.640 in @ Left 0.000 in @ Right 0.000 in Stress Calcs Bending Analysis Ck 19.865 Cv 0.866 Center Left Support @ Right Support Shear Analysis Design Shear Area Required Fv: Allowable Bearing @ Supports Max. Left Reaction Max. Right Reaction Le Rb Dead Load -0.427 in 15.000 ft 843.6 5.498 ft 6.254 Max Moment 151.64 k -ft 0.00 k -ft 0.00 k -ft @ Left Support 25.94 k 86.479 in2 300.00 psi Scope : General Timber Beam Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Center Span Left Cantilever Right Cantilever Douglas Fir, 24F - V4 Fb Base Allow Fv Allow Fc Allow E Total Load -1.233 in 15.000 ft 292.05 LL LL LL Reactions... Left DL Right DL Title : SOUTH CENTER RETAIL Job # 88-067007 Dsgnr: NA Date: 9:45AM, 28 AUG 08 Description : REPLACING TWO MECHANICAL UNITS #/ft #/ft 30.00 ft Lu ft Lu ft Lu 2,400.0 psi 240.0 psi 650.0 psi 1,800.0 ksi 881.30 #/ft #/ft #/ft Left Cantilever... Deflection ...Length /Defl Right Cantilever... Deflection ...Length /Deft Start Loc End Loc Maximum Shear * 1.5 Allowable Shear: Sxx 820.125 in3 Area 182.250 in2 CI 0.995 Sxx Req'd 704.25 in3 0.00 in3 0.00 in3 @ Right Support 25.96 k 86.519 in2 300.00 psi 20.44 k Bearing Length Req'd 4.658 in 20.21 k Bearing Length Req'd 4.607 in 2.67 ft 0.00 ft 0.00 ft 0.000 ft 1.042 ft Page 1 southctr- retail.ecw: Calc ulations Beam Design OK 26.0 k 54.7 k @ Left 20.44 k © Right 20.21 k Camber: © Left 0.000 in @ Center 0.640 in @ Right 0.000 in 7.22 k 6.99 k Allowable fb 2,583.76 psi 2,596.88 psi 2,596.88 psi Max 20.44 k Max 20.21 k Dead Load Total Load 0.000 in 0.000 in 0.0 0.0 0.000 in 0.000 in 0.0 0.0 5 •F %5 • Rev. 580004 User. KW -0806898, Ver 5.8.0, 1- Dec -2003 (c)1983 -2003 ENERCALC Engineering Software Description 6 3/4 X 27 GLB M, V, & D @ Specified Locations Center Span Location = Right Cant. Location = Left Cant. Location = 0.00 ft 0.00 ft 0.00 ft General Timber Beam Moment 0.00 k -ft 0.00k-ft 0.00 k -ft Title : SOUTH CENTER RETAIL Job # 88- 067007 Dsgnr: NA Date: 9•45AM, 28 AUG 08 Description : REPLACING TWO MECHANICAL UNITS Scope : I. of 4S Page 2 southctr -reta i I.ecw: Calculations Shear 20.44 k 0.00 k 0.00 k Deflection 0.0000 in 0.0000 in 0.0000 in • • - of 5 1304 30#. 11in;; ii ,iuin;i,inffin,in,n.uin;u,130430 _ 221.20 #!ft 221.20 #!ft 30.00 ft Mmax = 151.63 k -ft Dmax = - 1.2326 in Rmax = 20.436 k Rmax = 20.213 k Vmax @ left = 20.436 k Vmax @ rt = 20.213k Rev: 580004 User. KW -0606898, Ver 5.8.0, 1 -Dec -2003 (c)1983 -2003 ENERCALC Engineering Software Description 6 3/4 X 24 GLB General Information Section Name Beam Width Beam Depth Member Type Bm Wt. Added to Loads Load Dur. Factor Beam End Fixity Wood Density Full Length Uniform Loads Center Left Cantilever Right Cantilever Trapezoidal Loads #1 DL @ Left DL @ Right Summary @ Center @ Left Support @ Right Support Shear Analysis Design Shear Area Required Fv: Allowable Bearing @ Supports Max. Left Reaction Max. Right Reaction 6.75x24 Max Stress Ratio Maximum Moment Allowable Max. Positive Moment Max. Negative Moment Max @ Left Support Max @ Right Support Max. M allow fb 2,392.29 psi Fb 2,643.38 psi [eflections ry -.> Center Span... Deflection ...Location ...Length /Deft Camber ( using 1.5 * D.L. @ Center © Left @ Right [Stress Calcs Bending Analysis Ck 19.865 Le Cv 0.885 Rb DL DL DL 6.750 in 24.000 in GluLam 1.250 Pin -Pin 34.000 pcf 184.40 #/ft 184.40 #/ft 423.00 #/ft LL #/ft LL #/ft LL Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined LL @ Left LL @ Right Span= 27.00ft, Beam Width = 6.750in x Depth = 24.in, Ends are Pin -Pin 0.905 : 1 129.2 k -ft 142.7 k -ft 129.18 k -ft 0.00 k -ft 0.00 k -ft 0.00 k -ft 142.74 fv 151.00 psi Fv 300.00 psi Dead Load -0.454 in 13.608 ft 714.4 Defl) 0.680 in 0.000 in 0.000 in 5.498 ft 5.896 Max Moment 129.18 k -ft 0.00 k -ft 0.00 k -ft @ Left Support 24.03 k 80.097 in2 300.00 psi 18.63 k 18.92 k Scope : General Timber Beam Center Span Left Cantilever Right Cantilever Douglas Fir, 24F - V4 Fb Base Allow Fv Allow Fc Allow E at 13.716 ft at 0.000 ft Total Load -1.206 in 13.500 ft 268.57 Reactions... Left DL Right DL Sxx 648.000 in3 CI 0.995 Sxx Req'd 586.45 in3 0.00 in3 0.00 in3 @ Right Support 24.46 k 81.540 in2 300.00 psi Title : SOUTH CENTER RETAIL Job # 88-067007 Dsgnr: NA Date: 2:17PM, 1 SEP 08 Description : REPLACING TWO MECHANICAL UNITS #/ft #/ft Bearing Length Req'd Bearing Length Req'd 27.00 ft ft ft 2,400.0 psi 240.0 psi 650.0 psi 1,800.0 ksi 881.30 #/ft #/ft #/ft Maximum Shear * 1.5 Allowable Shear: 24.5 k 48.6 k @ Left 18.63 k @ Right 18.92 k Camber: @ Left 0.000 in @ Center 0.680 in @ Right 0.000 in 6.73 k 7.02 k Left Cantilever... Deflection ...Length /Deft Right Cantilever... Deflection ...Length /Defl Lu Lu Lu Start Loc End Loc Dead Load 0.000 in 0.0 0.000 in 0.0 Area 162.000 in2 Allowable fb 2,643.38 psi 2,655.48 psi 2,655.48 psi 4.246 in 4.312 in 2.67 ft 0.00 ft 0.00 ft 12.980 ft 20.021 ft Page 1 southctr- retaiLecw: Calculations Beam Design OK Max 18.63 k Max 18.92 k Load 0.000 in 0.0 0.000 in 0.0 8 oL 15 • Rev: 580004 User. KW -0606898, Ver 5.8.0, 1- Dec -2003 (c)1983.2003 ENERCALC Engineering Software Description 6 3/4 X 24 GLB uery Values M, V, & D @ Specified Locations @ Center Span Location = @ Right Cant. Location = @ Left Cant. Location = 0.00 ft 0.00 ft 0.00 ft General Timber Beam Moment 0.00 k -ft 0.00 k -ft 0.00 k -ft Title : SOUTH CENTER RETAIL Job # 88 -067007 Dsgnr: NA Date: 2:17PM, 1 SEP 08 Description : REPLACING TWO MECHANICAL UNITS Scope : of IS Page 2 southctr -retai I. ecw:Calculations Shear 18.63 k 0.00 k 0.00 k Deflection 0.0000 in 0.0000 in 0.0000 in • • 1304 .30 - 1#A N^ Rmax = 18.629 k Vmax ® left = 18.629 k 184.40 #/ft Mmax = 129.18 k -ft Dmax = - 1.2063 in 184.40 #/ft Rmax = 18.917 k Vmax (drt = 18.917k • • • ENW ENGINEERS NORTHWEST, INC., P.S. - STRUCTURAL ENGINEERS PROJECT # 0(o1 PROJECT , DO-T11 CTE. kETP SUBJECT e 3/4 X 31 Vz. GL! x,12 P) 35 ,2s (25 PSF (3S, 25 6869 WOODLAWN AVE. N. E., #205, SEATTLE, WA 98115 (206) 5257560 FAX (206) 522-6698 \ \J t^k (,1 6 LOAD I\K7 L\23 KS:- ,q, .ZS to -O' srmi = 48' -0" TR�B U.J jb1' 3.2S 4 P, 20,t-136 K y CL-t I DATE c{ 1' f 2-COY SHEET 11 OF 15 BY N Rev: 580004 User: KW-0606898, Ver 5.8.0, 1-Dec -2003 (c)1983 -2003 ENERCALC Engineering Software Description 6.75x31.5 GLB General Information Section Name 6.75x31.5 Beam Width 6.750 in Beam Depth 31.500 in Member Type GluLam Bm Wt. Added to Loads Load Dur. Factor Beam End Fixity Wood Density Full Len s th Uniform Loads Center DL Left Cantilever DL Right Cantilever DL [Point Loads Dead Load Live Load ...distance L Summary Max. Positive Moment Max. Negative Moment Max @ Left Support Max @ Right Support Max. M allow fb 1,580.22 psi Fb 2,495.53 psi 1.250 Pin -Pin 34.000 pcf 20,436.0 Ibs 18,917.0 Ibs Ibs lbs 42.000 ft -6.000 ft Max Stress Ratio 0.633 : 1 Maximum Moment -147.0 k -ft Allowable 232.1 k -ft Deflections Center Span... Dead Deflection 0.587 in ...Location 18.289 ft ...Length /Deft 735.5 Camber ( using 1.5 * D.L. Defl ) ... @ Center 0.881 in @ Left 0.795 in @ Right 0.832 in 423.00 #/ft 423.00 #/ft 423.00 #/ft 92.87 k -ft - 131.13 k -ft - 137.88 k -ft - 147.00 k -ft 232.14 fv 177.46 psi Fv 300.00 psi General Timber Beam Center Span Left Cantilever Right Cantilever Douglas Fir, 24F - V8 Fb Base Allow Fv AIIow Fc Allow E Ibs Ibs 0.000 ft at 17.904 ft at 36.000 ft Total Load -0.527 in 17.904 ft 819.57 LL LL LL Reactions... Left DL Right DL Title : SOUTH CENTER RETAIL Job # 88-067007 Dsgnr: NA Date: 2:39PM, 1 SEP 08 Description : REPLACING TWO MECHANICAL UNITS Scope : Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Ibs Ibs 0.000 ft Left Cantilever... Deflection ...Length /Defl Right Cantilever... Deflection ...Length /Defl 36.00 ft Lu 6.00 ft Lu 6.00ft Lu 2,400.0 psi 240.0 psi 650.0 psi 1,700.0 ksi 881.30 #/ft 881.30 #/ft 881.30 #/ft Span= 36.00ft, Left Cant= 6.00ft, Right Cant= 6.00ft, Beam Width = 6.750in x Depth = 31.5in, Ends are Pin -Pin Maximum Shear * 1.5 Allowable Shear: @ Left @ Right Camber: @ Left @ Center @ Right 30.02 k 32.05 k Ibs Ibs 0.000 ft Max Max Page 1 southctr- retail.ecw: Calculations 2.67 ft 2.67 ft 2.67 ft Ibs Ibs 0.000 ft Beam Design OK 37.7 k 63.8 k 26.78 k 28.30 k 0.795 in 0.881 in 0.832 in 51.61 k 53.64 k it oG 15 Ibs Ibs 0.000 ft Dead Load Total Load -0.530 in -0.636 in 271.6 226.4 -0.555 in -0.658 in 259.5 219.0 Rev: 580004 User. KW -0606898, Ver 5.8.0, 1- Dec-2003 (c)1983 -2003 ENERCALC Engineering Software Description 6.75x31.5 GLB Stress Calcs Bending Analysis Ck 19.306 Le Cv 0.837 Rb @ Center @ Left Support @ Right Support Shear Analysis Design Shear Area Required Fv: Allowable Bearing @ Supports Max. Left Reaction Max. Right Reaction Query Values M, V, & D @ Specified Locations @ Center Span Location = @ Right Cant. Location = @ Left Cant. Location = 5.498 ft 6.755 Max Moment 131.13 k -ft 137.88 k -ft 147.00 k -ft @ Left Support 35.45 k 118.180 in2 300.00 psi 51.61 k 53.64 k 0.00 ft 0.00 ft 0.00 ft Scope : General Timber Beam Sxx 1,116.281 in3 CI 0.994 Sxx Req'd 630.57 in3 663.02 in3 706.85 in3 @ Right Support 37.73 k 125.775 in2 300.00 psi Title : SOUTH CENTER RETAIL Job # 88-067007 Dsgnr: NA Date: 2:39PM, 1 SEP 08 Description : REPLACING TWO MECHANICAL UNITS Bearing Length Req'd Bearing Length Req'd Moment - 137.88 k -ft - 137.88 k -ft - 137.88 k -ft Area 212.625 in2 Allowable lb 2,495.53 psi 2,495.53 psi 2,495.53 psi 11.764 in 12.225 in Shear 24.13 k 24.13 k 24.13 k i3 oL 15 Page 2 southctr - retail. ecw: Calcu lations Deflection 0.0000 in 0.0000 in 0.0000 in • 18917.0 Ibs 30430 — Illl�llllllllill :;I;II;IIIIIIIILI 3°43- p .. n#ift Mmax © left = - 137.88 k -ft Rmax = 51.612 k Vmax ® left = 26.781 k Defl ® left end = 0.6359 in Mmax = 131.13 k -ft Dmax = - 0.5271 in IH aF 15 20436.00 Ibs 1304.30 #/ft 1 1 1 1304.30 ##ft Mmax © right = - 146.99 k -ft Rmax = 53.637 k Vmax (4) rt = 28.300 k Defl © right end = 0.6576 in • • • ENW ENGINEERS NORTHWEST, INC., P.S. - STRUCTURAL ENGINEERS PROJECT # ' N D taq 4 PROJECT � o' 1 (r'( 67E. r L SUBJECT z x g- r3o Lrs C (E)Efj¢A116" 6tvIc,I4.- RoAE fl ctc n.s� 6869 WOODLAWN AVE. N. E., #205, SEATTLE, WA 98115 (206) 525 -7560 FAX (206) 522 -6698 X(sr7N6- (oNN c Co �, z, ,. ° (L-) cam' 0.71(' 0,1S" ( 3ecr /cn/ G - ,54ir -7 E.S. mac- e' , O� �Ji�l= E, Et\/T i.JIgTNS W ` /4 '' . / t_ ca DATE 9/ 2 1 2 . 457dJ SHEET { S OF 15 BY N I� 0 TOP Cooling Equipment Schedule Equip. ID Brand Name' Model No.' Capacity Btu/h Total CFM OSA CFM or Econo? SEER or,_ R IPLV Location RTU-1 AMERICAN STANDARD YSC102E 102070 3400 68 / _` d IAi ROOF RTU-2 AMERICAN STANDARD YSC120E 118000 4000 8 0 10.¢, R 162000 oz.... REC rvi SEP p g g p iO MP PERMIT utn i ' d8 Heating Equipment Schedule � fr 1 a' v ' Equip. ID Brand Name' Model No.' Capacity Btu/h Total CFM OSA cfm or Econo? '-.. Input Btuh 'Ou t , tuh Efficiency RTU -1 AMERICAN STANDARD YSC102E 121500 3400 680 150000 121500 81.000 RTO -2 AMERICAN STANDARD YSC12OE 162000 4000 800 200000 162000 81.000 REC rvi SEP p g g p iO MP PERMIT utn Fan Equipment Schedule Equip. ID Brand Name' Model No.' CFM SPA HP /BHP Flow Control Location of Service EF -1,2 BROAN QTR110 90 0.20 71W BATHROOMS REC rvi SEP p g g p iO MP PERMIT utn Project Info Project Address Souht Center Retail Suite 101 and 105 Date 9/9/2008 16901 Southcenter Parkway For Building Dept. Use Tukwila, WA Applicant Name: Evergreen Refrigeration Applicant Address: 727 g Kenyon St. Applicant Phone: 206 -763 -1744 2006 Washington State Nonresidential Energy Code Compliance Form ,Mechanical, Summary MECH -SUM 2006 Washington State Nonresidential Energy Code Compliance Forms Project Description Briefly describe mechanical system type and features. ❑ Includes Plans Install (2) rooftop packaged HVAC units and (2) rooftop exhuast fans. FE MC Ito A Include documentation requiring compliance with com Issioni g' Tequiterwas , Section 1416. Compliance Option QQ Simple System O Complex System O Systems Analysis • •• • - • • - ,• - - - ,, (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. 'If available. 2 As tested according to Table 14 -1A through 14 -1G. 3 If required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as Revised July 2007 TEF, II avauauio. na icaiou .i3RQV ')imbicOnvi5USail\howidanSti94, &off a applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Permit PI'ans Ch�'ecklist 2006 Washington State Nonresidential Energy Code Compliance Forms MECH Project Address Souht Center Retail Suite 101 and 105 (Date 9/9/2008 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. .Information Required HVAC, REQUIREMENTS (Sections 1401 -1424) 1 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency 1411.1 Combustion htg. Indicate intermittent ignition, flue/draft damper & jacket loss 1412 HVAC controls Revised July 2007 Applicability Code (yes, no, n.a.) Section IComponent I I Location Building Department on Plans I Notes 1411 Equipment performance 1 M1 1 1411.4 Pkg. elec. htg.& clg. (List heat pumps on schedule Optimum Start 1412.1 Temperature zones Indicate locations on plans Mi 1412.2 Deadband control Indicate 5 degree deadband minimum M1 1412.3 Humidity control Indicate humidistat MI. 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage 1412.4.2 Indicate optimum start controls M1 1412.5 Heat pump control Indicate microprocessor on thermostat schedule 1412.6 Combustion htg. Indicate modulating or staged control 1412.7 Balancing Indicate balancing features on plans 1412.8 Ventilation Control Indicate demand control ventilation for high - occupancy areas 1422 Thermostat interlock Indicate thermostat interlock on plans 1423 Economizers M1 Equipment schedule 1413 Air economizers 1413.2 1413.1 Air Econo Operation Indicate 100% capability on schedule 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb Water Econo Doc Indicate clg load & water.econoe & clg tower performance 1413.3 Integrated operation Indicate capability for partial cooling 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems 1 M1 M1 1414.1 Duct sealing Indicate sealing necessary 1414.2 Duct insulation Indicate R -value of insulation on duct 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Completion Requirements Commissioning 1416.2.1 Commissioning Provide commissioning plan 1416.2.2 -3 Sys.Bal & Func.Test Indicate air and water system balancing & functional testing 1416.2.4 Indicate O &M manuals, record drawings, staff training Mechanical Summary Form Completed and attached. Equipment schedule with types, IMi efficiency, input/output, SERVICE! WATER HEATING AND HEATED POOLS (Sections 1440 -1454) Service water htg. 1416.2.5 Comm. Report Indicate requirements for prelim. & final commissioning report Mi 1434 Separate air sys. Indicate separate systems on plans 1440 1441 1442 1443 1452 1452 1453 1454 Elec. water heater Shut -off controls Pipe Insulation Heat Pump COP Heater Efficiency Pool heater controls Pool covers 1454 Pools 90+ degrees Indicate R -10 insulation under tank Indicate automatic shut -off Indicate R -value of insulation on piping Indicate minimum COP of 4.0 Indicate pool heater efficiency Indicate switch and 65 degree control Indicate vapor retardant cover Indicate R -12 pool cover 2006 Washington State Nonresidential Energy Code Compliance Form ; Mechanical Perrn,it Plans ,Checklist MECH ! 2006 Washington State Nonresidential Energy Code Compliance Forms 'Revised July 2007 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified Sting conditions not less than the values shown in Table 14-1A through 14 -1G. If a .rationally recognized certification program exists for a product covered in Tables 14 -1A through 14-1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings > 225,000 Btu/h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable altemative to a flue damper for fumaces where combustion air is drawn from the conditioned space. All furnaces with input ratings > 225,000 Btu/h (65 kW), including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be fumished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Cooling Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu/h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a huilding shall be considered as a separate zone. 112.2 Deadband Controls: When used to control both comfort heating and .tooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or altemate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu/h) or Less may be controlled by readily accessible manual off-hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) impers. These dampers shall remain closed until activated by the fire alarm ./stem or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stones in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings 1412.8 Ventilation Controls for High- Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and intemal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. • 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu/h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246- 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu/h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, EF CAE < 50 gal storage 0.58 0.71 50 to 70 gal storage 0.57 0.71 > 70 gal storage 0.55 0.70 2006 Washington State Nonresidential Energy Code Compliance Form ; Mechanical Perrn,it Plans ,Checklist MECH ! 2006 Washington State Nonresidential Energy Code Compliance Forms 'Revised July 2007 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified Sting conditions not less than the values shown in Table 14-1A through 14 -1G. If a .rationally recognized certification program exists for a product covered in Tables 14 -1A through 14-1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings > 225,000 Btu/h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable altemative to a flue damper for fumaces where combustion air is drawn from the conditioned space. All furnaces with input ratings > 225,000 Btu/h (65 kW), including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be fumished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Cooling Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu/h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a huilding shall be considered as a separate zone. 112.2 Deadband Controls: When used to control both comfort heating and .tooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or altemate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu/h) or Less may be controlled by readily accessible manual off-hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) impers. These dampers shall remain closed until activated by the fire alarm ./stem or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stones in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings 1412.8 Ventilation Controls for High- Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and intemal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. • 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu/h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246- 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu/h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, (�(��/�� Gntial_Eaer Code Camplianca.Form _ _ _..., - ._. - _ . ..._. __•- - __ _ • . -T. u�a�i ����+��' �'u�v��< cur u�QitlFS !l�i.LL" l`f1, 11a`7C��Y duct run considered building envelope until they, outlets in the first story and levels below the first story of buildings 1. connect cons considered to the heating or cooling equipment, th, or • three or more stories in height. are isolated from the exterior with an automatic shut -off damper complying 141214.2 Optimum Start Controls: Heating and cooling systems with design supply 2. with Section 1412.4.1. air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum start controls shall be designed to automatically adjust the start time of an HVAC Once outside air ducts meet the above listed requirements, any runs within system each day to bring the space to desired occupied temperature levels conditioned space shall comply with Table 14 -5 requirements. •-nmediately before scheduled occupancy. The control algorithm shall, as a Other ducts and plenums shall be thermally insulated per Table 14 -5. iinimum, be a function of the difference between space temperature and occupied Exceptions: setpoint and the amount of time prior to scheduled occupancy. 1. Within the HVAC equipment. 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include s n ducts ucts ot subject to condensation. microprocessor controls that minimize supplemental heat usage during start-up, set - 2. Exhaus2. Exhaust Exhaust air ductwork ot ts a zone that serves that zone. up, and defrost conditions. These controls shall anticipate need for heat and use S compression heating as the first stage of heat. Controls shall indicate when 1 415 Piping Systems supplemental heating is being used through visual means (e.g., LED indicators). 1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14-6. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment Exception: Piping installed within unitary HVAC equipment. with a capacity over 225,000 Btu/h shall have modulating or staged combustion Water pipes outside the conditioned space shall be insulated in accordance with control. 000 Washington State Plumbing Code (WAC 51 -26) EXCEPTIONS: 1. Boilers. 2. Radiant heaters. 1416 Completion Requirements (Refer to NREC Section 1416 and the Building 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have Commissioning Guidelines, published by the Building Commissioning Association, a means for balancing, including but not limited to, dampers, temperature and for complete text and guidelines for building completion and commissioning pressure test connections and balancing valves. requirements.) ACTIVITY NUMBER: M08 -226 X Original Plan Submittal Response to Correction Letter # DATE: 09 -09 -08 PROJECT NAME: VACANT SPACE SITE ADDRESS: 16901 SOUTHCENTER PY SUITE 105 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: BU1QA' ivision Public Works Complete Comments: REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28-02 �ERMIT COORD COPY PLAN REVIEW/ROUTI ► I ALUt/ 6 1-1 2 -08 Fire Prevention Structural Incomplete n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) G SLIP Planning Division Permit Coordinator DUE DATE: 09 -11 -08 TUES/THURS R TING: Please Route Structural Review Required n No further Review Required DATE: Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DUE DATE: 10 -09 -08 Approved ❑ Approved with Conditions i Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit CenterUse•Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 TRAVELERS CAS It SURETY CO 104667361 01/01/2006 Until Cancelled 01/06/2006 $12,000.00 01/03/2006 Name Role Effective Date Expiration Date EVERGREEN REFRIGERATION LLC PARTNER /MEMBER 12/22/2005 Amount PATTON, DAVID PARTNER /MEMBER 01/06/2006 PATTON, RODGER PARTNER /MEMBER 01/06/2006 PATTON, MATTHEW PARTNER /MEMBER 01/06/2006 Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date CONTINENTAL Untitled Page General /Specialty Contractor • A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type LIMITED LIABILITY COMPANY Parent Company EVERGREEN REFRIGERATION LLC 2067631744 727 S KENYON ST SEATTLE WA 98108 KING UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 602512953 ACTIVE EVERGRL954R2 CONSTRUCTION CONTRACTOR 1/6/2006 1/6/2010 EVERGI "201 D7 GENERAL UNUSED Business Owner Information Bond Information Insurance Information Page 1 of 2 https: / /fortress.wa. gov /lni/bbip/Detail. aspx ?License= EVERGRL954R2 09/19/2008 SYMBOL LEGEND SYMBOL ABBV. DESCRIPTION . 0 S.P. DUCT SECTION SUPPLY Fea Hp/A DUCT SECTION - RETURN /EXHAUST SOUTHCENTER RETAIL ##101 & ##105 RECTANGULAR DUCT 16901 SOUTHCENTER PARL'''AY TU ICI LA, WA 98188 ROUND DUCT EF 1,2 BROAN FLEXIBLE DUCT 90 MVD MANUAL VOLUME DAMPER L ! BDD BDD BACKDRAFT DAMPER © MD MOTORIZED DAMPER FD FIRE DAMPER ____, 4 FSD FIRE /SMOKE DAMPER (120V POWER REQ.) CEILING RADIATION DAMPER sD SD SMOKE DETECTOR 0 T THERMOSTAT S SENSOR - - R R REFRIGERANT LINES -- - - -R -- - - -G G NATURAL GAS LINES rte' CEILING DIFFUSER (SUPPLY) rar CEILING DIFFUSER (RETURN /EXHAUST) a EXHAUST FAN (CEILING MOUNTED) CF INLINE FAN lh.t1 T•rn ., el nano JEa u 15 i uuu PROPELLER FAN r,r.T]IIAIT r'ENITPF \ I f A L.1 nr ,. SIDEWALL DIFFUSER DUCT FITTING DATUM t TA CP,Ar UNIT TAG B.O.J. 1 2' 2" ✓E9 FP 2 It DUCT RISER EXHAUST FAN SCHEDULE MARK MANF. MODEL CFM S.P. VOLTS PHASE Hp/A NOTES SOUTHCENTER RETAIL ##101 & ##105 COVER SHEET 16901 SOUTHCENTER PARL'''AY TU ICI LA, WA 98188 EF 1,2 BROAN QTR110 90 0.2" 115 1 71 W LOCATED ON CEILING NOT PUBLISHED. ALL RIGHTS RESERVED. THE DRAWING AND SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF EVE- RGREEN REFRIGERATION INC. NO PART THEREOF - SHALL BE REPRODUCED, COPIED, ADAPTED. DISC- LOSED OR DISTRIBUTED TO OTHERS, SOLD, PUB- LISHED OR OTHERWISE USED WITHOUT THE PRIOR WRITTEN CONSENT OF AND APPROPRIATE COMPEN- SATION TO EVERGREEN REFRIGERATION INC. VISUAL CONTACT WITH THE ABOVE DRAWINGS OR SPECIFIC- ATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. I I I I I I I I I I SOUTHCENTER RETAIL ##101 & ##105 COVER SHEET 16901 SOUTHCENTER PARL'''AY TU ICI LA, WA 98188 illPrisrPL Illvtt-adiiiiiIiiiiiiiiiiiii m In 1.96Laro m 4 11111 iilinillilliPir II 6� 1 ii 1 0 1111 mow film li oplimii__Nal IN mu murilmrion Ell II El num NM I 11 1 onimmoillwAriall 11111 11111111 11 III 1111 6h1111111111111 MEL - 1111110111111111 111111 mom m � 111 i Ingsale 1 RE tan oil nom III IMP iv 11111111; Mill In 1 x; 1 0 4 w 6 1 Ili 1IUI `III 111 11111111111111111111111 MI II 111111111111111114 1111 IIiIIIII illiIIIIl 11 1111 Ild1111611111111111 A; 1111111 11111 IN VICINITY MAP SCALE NONE pan 7 Permit No. lar review approval Is aub oct to eau and crr! zs! n s. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Rec ;tpt of approved Fiel, Copy and cfitions is acknowledged: By D ate•_ rrinrrri�r City of Tukwila BU L!) NC DiViSION 1, IS ( c� i� InNS No r7;h..''Tt7O sh I!! be mprlrn to rh" ^r^rn Of 1,A. 7rk '.ti +itl CI!f prior • Tukwila w ,I imn/ ..I ,)El'"'r'tRl TI . % t' 'fvii 1 .1 kEQU RE D FOR: 0 MechiAnical L EElectrical [Plumbing Gas Piping City of Tukwila pIVISION HVAC FLOOR PLAN SCALE : 1/8" = 1 1_ 0 Al MARK RTU 1 RTU 2 MANF. AMERICAN STANDARD AMERICAN STANDARD MODEL YSC102E YSC120E TONS. 8.5 8" UP 10 AIRFLOW CFM 3,400 4,000 SP INS 0.5" 0.5" MIN. OSA CFM PACKAGED HEAT PUMP EQUIPMENT SCHEDULE 680 800 MOTOR HP DRIVE #1 #1 COOLING SEER TOTAL BTUH 102,070 118,000 EER 11.2 10.6 INPUT BTUH 150,000 200,000 HEATING OUTPUT BTUH 121,500 162,000 AFUE 81% 81% VOLTS V 460 460 COMPLETION AND COMMISSIONING FOR MECHANICAL SYSTEMS RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER WA ENERGY CODE (WSEC) SECTION 1416.1. AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER PER WSEC SECTION 1416.2.4.1 ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCE REPORT SHALL BE PROVIDED TO THE OWNER PER WSEC SECTION 14516.2.2.1. FOR WAREHOUSES SEMIHEATED SPACES AND SIMPLE SYSTEMS LAS DEFINED IN WSEC SECTION 1421): HVAC CONTROL SYSTEMS SHALL BE TESTED, CALIBRATED AND ADJUSTED, SEQUENCES OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORD WITH SPECIFICATIONS AND APPROVED PLANS, AND A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE FILED WITH THE OWNER PER WSEC SECTION 1416.2.3.2. FOR ALL. OTHER SYSTEMS: HVAC CONTROL SYSTEMS SHALL BE TESTED, CALIBRATED AND ADJUSTED, SEQUENCES OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORD WITH SPECIFICATIONS AND APPROVED PLANS PER WSEC SECTION 1416.2.3.2; NECESSARY TESTS SHALL BE IDENTIFIED PER WSEC SECTION 1416.2.3; A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY PER WSEC SECTION 1416.2,11 AND A COMPLETE FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE FILED WITH THE OWNER PER WSEC SECTION 1416,2.5.2. PHASE 30 30 ELECTRICAL M.C.A. (A) 21.9 26.5 MOP (A) 25 35 UNIT LBS 945 1050 ECON LBS WEIGHT 36 36 CURB LBS 115 115 TOTAL WEIGHT LBS 1096 1201 DUCTWORK GENERAL NOTES 1.1 ALL DUCT DIMENSIONS ON PLAN ARE CLEAR INSIDE DIMENSIONS, ADD 2" TO EACH DIMENSION TO OBTAIN OUTSIDE DIMENSION. ADD 4 "TO EACH DIMENSION IF DUCTWORK IS ON THE EXTERIOR OF BUILDING. 1.2 THE FIRST NUMBER ON ALL DUCT DIMENSIONS IS THE WIDTH AND THE SECOND NUMBER IS THE HEIGHT. 1.3 MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT RATING LESS THAN 50, PER IMC 602.2.1. 1.4 SEAL ALL TRANSVERSE JOINTS FOR DUCTWORK WITH STATIC PRESSURE BETWEEN 1/2 INCHES AND 2 INCHES. DUCTWORK WHICH I5 DESIGNED TO OPERATE AT PRESSURES ABOVE 1/2 INCH WATER COLUMN STATIC PRESSURE SHALL BE SEALED IN ACCORDANCE WITH STANDARD RS -7. 1.5 ALL DUCT GAUGES PER SMACNA, IMC 603 -4. 1.6 ALL DUCT SUPPORTS PER SMACNA, IMC 603 -10. 1.7 ATTACH DIF =USERS AND GRILLES TO T -BAR GRID PER WA STATE & LOCAL CODES. 1.8 BALANCING DAMPERS ARE TO BE INSTALLED ON ALL BRANCH DUCTS OR DIFFUSERS. INSULATION 2.1 INSULATE OR LINE DUCTWORK PER WA, STATE ENERGY AND MECHANICAL CODES. 2.2 INSULATE REFRIGERANT & CONDENSATE PIPING PER STATE & LOCAL ENERGY CODES. GENERAL CONTRACTOR 3.1 GENERAL CONTRACTOR TO PROVIDE AND CUT OPENINGS FOR ALL ROOFTOP CEILING, FLOOR, AND WALL PENETRATIONS, INCLUDING WEATHERPROOF SEALING AND FIRE PROOF LINING PER IMC & IBC. 3.2 GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATION AND DIMENSIONS WITH ERL BEFORE FRAMING OPENINGS. 3.3 GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING, AND PAINTING AS REQUIRED FOR MECHANICAL WORK. 3.4 GENERAL CONTRACTOR TO PROVIDE ADEQUATE STRUCTURAL SUPPORT AS REQUIRED FOR MECHANICAL WORK. 3.5 GENERAL CONTRACTOR TO PROVIDE ADEQUATE ENGINEERING AS REQUIRED FOR MECHANICAL WORK. 3.6 GENERAL CONTRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL MECHANICAL_ EQUIPMENT. 3.7 GENERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY ERL PROVIDE ALL CANT STRIPS AND CURB INSULATION, AND SEAL AGAINST LEAKS. 3.8 GENERAL CONTRACTOR TO PROVIDE ALL CUTTING AND PATCHING OF T -BAR CEILING AS REQUIRED FOR HVAC INSTALLATION. 3.9 GENERAL CONTRACTOR TO PROTECT ALL OPENINGS THROUGH FLOORS PROVIDED FOR DUCTWORK INSTALLATION IN ACCORDANCE WITH TABLE 601 OF INTERNATIONAL BUILDING CODE, WHERE REQUIRED BY SECTION 707 OF IBC. ELECTRICAL 4.1 ERL TO INSTALL ALL LOW VOLTAGE CONTROL WIRING, CONDUIT WILL BE PROVIDED BY ELECTRICAL CONTRACTOR. 4.2 ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL CONNECTIONS, DISCONNECTS, AND STARTERS FOR MECHANICAL EQUIPMENT. 4.3 ELECTRICAL CONTRACTOR TO VERIFY EQUIPMENT SIZES, LOADS AND LOCATIONS WITH ERL MECHANICAL PLAN AND WITH FIELD CONDITIONS. 4.4 ELECTRICAL CONTRACTOR TO INTERLOCK BATHROOM EXHAUST FANS WITH LIGHT SWITCH. 4.5 ERL TO PROVIDE 7 -DAY NIGHT SETBACK, PROGRAMMABLE TYPE T -STAT WITH CAPABILITY OF 5 °F DEADBAND. 4.6 ERL TO VERIFY FINAL LOCATION OF THERMOSTAT WITH CUSTOMER. 4.7 ELECTRICAL CONTRACTOR TO PROVIDE ELECTRICAL GCFI OUTLET 1MTHIN 25 FT OF EACH PIECE OF MECHANICAL EQUIPMENT. PLUMBING 5.1 PLUMBING CONTRACTOR TO FURNISH AND INSTALL ALL GAS PIPING FOR MECHANICAL EQUIPMENT PER CODE. 5.2 PLUMBING CONTRACTOR OFFSET VENTS 10 FEET MINIMUM FROM ALL HVAC FRESH AIR INTAKES OR 2' ABOVE HIGHEST POINT OF INTAKE, IMC 401.5.1. 5.3 CONDENSATE DRAINS FROM RTU BY ERI TO DRAIN WITHIN 12" OF UNIT. CONDENSATE DRAINS FOR AIR HANDLERS BY PLUMBER. ENERGY CODE COMPLIANCE 6.1 AT A MINIMUM, EACH FLOOR IS TO BE CONSIDERED A SEPARATE ZONE. VERIFY THERMOSTATIC CONTROL FOR EACH ZONE AS INDICATED ON PLANS. 6.2 OUTSIDE AIR INTAKES, EXHAUST OUTLETS, AND RELIEF OUTLETS SERVING CONDITIONED SPACES SHALL BE EQUIPPED WITH DAMPERS WHICH CLOSE AUTOMATICALLY WHEN THE SYSTEM IS OFF OR UPON POWER FAILURE, PER WSEC SEC. 1412.4.1. 6.3 AIR ECONOM.ZERS WHERE REQUIRED BY CODE ARE INDICATED BY THE EQUIPMENT SCHEDULE AT 100% CAPABILITY, CONTROL AND OPERATION OF THE ECONOMIZER SHALL COMPLY WITH WSEC SEC. 1423. MECHANICAL CODE COMPLIANCE 7.1 WHERE REQUIRED PROVIDE AUTOMATIC SHUTOFF ACTIVATED BY SMOKE DETECTORS IN EACH SYSTEM DELIVERING HEATING OR COOLING AIR IN EXCESS OF 2000 CFM. DETECTORS 13HALL BE LOCATED IN THE MAIN RETURN AIR PER IMC 606. WA2004 #1 U sarni w *21 V '1 z a z ci) uJ 0) 0