Permit M08-228 - DIGITAL FOREST - UPS ROOM
DIGITAL FOREST UPS ROOM 12101 TUKWILA INTERNATIONAL BL EXPIRED 03 -28 -09 M08 -228 Parcel No.: 0923049031 Address: Suite No: 12101 TUKWILA INTERNATIONAL BL TUKW Tenant: Name: DIGITAL FOREST, UPS ROOM Address: 12101 TUKWILA INTERNATIONAL BL, STEE 410 , TUKWILA WA Owner: Name: INTERNATIONAL GATEWAY WEST Address: 12201 TUKWILA INTERNATIONAL BLVD , SEATTLE WA Contact Person: Name: JARED SHEEKS Address: 7717 DETOIT AV SW , SEATTLE WA Contractor: Name: MACDONALD /MILLER FAC SOL INC Address: PO BOX 47983 , SEATTLE, WA Contractor License No: MACDOFS980RU DESCRIPTION OF WORK: INSTALL (1) 15 -TON PACKAGE ROOFTOP A/C UNIT, SUPPLY DUCTWORK, AND TIE INTO EXISTING DUCTWORK. INSTALL (1) BACKDRAFT DAMPER. INSTALL (1) MOTORIZED CONTROL DAMPER. Value of Mechanical: $17,742.00 Type of Fire Protection: Furnace: <100K BTU 0 >100K BTU 0 Floor Furnace 0 Suspended/Wall/Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System.... 0 Air Handling Unit <10,000 CFM 1 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 0 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial/Industrial 0 doc: IMC-10/06 Cit.* Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT EQUIPMENT TYPE AND QUANTITY * *continued on next page ** • Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 768 -3806 Phone: 206 - 768 -4180 Expiration Date: 12/31/2008 M08 -228 09/29/2008 03/28/2009 Fees Collected: $372.50 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 2 M08 -228 Printed: 09 -29 -2008 Permit Center Authorized Signature: Signature: doc: IMC -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • Permit Number: M08 -228 Issue Date: 09/29/2008 Permit Expires On: 03/28/2009 Date: C ign 1,P I hereby certify that I have read and $xanvned this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be compile wig., whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction ore performance of work. I am authorized to sign and obtain this mechanical permit. Print Name: 4 Tit A. .� e- Date: cF c lay This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M08 -228 Printed: 09 -29 -2008 Parcel No.: 0923049031 Address: Suite No: Tenant: 12101 TUKWILA INTERNATIONAL BL TUKW DIGITAL FOREST, UPS ROOM 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 5: Readily accessible access to roof mounted equipment is required. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 12: ** *FIRE DEPARTMENT CONDITIONS * ** doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: M08 -228 ISSUED 09/12/2008 09/29/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 15: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the M08 -228 Printed: 09 -29 -2008 0 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 16: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 17: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 18: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 19: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 20: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 21: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 22: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 23: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond - 10/06 * *continued on next page ** M08 -228 Printed: 09 -29 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: doc: Cond -10/06 1 ,9,44,_ ■ Date: 69 / do ordinances governing or local laws regulating M08 -228 Printed: 09 -29 -2008 King Co Assessor's Tax No.: (0 9 ) y 4 30$ Site Address: 1 Z 1 0 ( '(,,, \L A ,...) i \ 0 '1,,rAyi /t't_ 1 o v■ c1 i 1V A Suite NumbeP 1 / 0 Floor: i) iP 5 UM Tenant Name: — 0 \. 1 i - } - c,A ov� e._g{- - L) e 5 6 - N . New Tenant: ❑ Yes �..No Property Owners Name: 1D i C ; - c.5. V--o'r i .t- Mailing Address: l Z-1 D 1 "Tuli--k.-) , \ A .1 (.2 C.0 f ) u —'i )a Name: jape. SU) SIZAAtte. c f Q(L , City State Zip Fax Number: Mailing Address: - 1 - 1 1Q, "t irb E -Mail Address: GENERAL CONTRACTOR =INFORMATIO: (Contractor Info(matiodfor Mechanical (pg 4)),for Plambing an Company Name: Mailing Address: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukvvila.wa.us ENGINEER OF "RECORD - All plans Inns QAApphcanonsV'orms.Applrcaaens On Line \3.2006 - Permit Application.doc Revised: 4 -2006 bh Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Contact Person: E -Mail Address: Contractor Registration Number: ARCHITECT OF RECORD - All plans ' mast be wet stamped by Architectaof Recoi Contact Person: E -Mail Address: Contact Person: E -Mail Address: City City v� A State Day TelephontEZ-d-) /C4 31 (1(y State Day Telephone: Fax Number: -- 'Rpir on Date: Company Name: Mailing Address: City Day Telephone: Fax Number: State Company Name: Mailing Address: City Day Telephone: Number: State Zip Zip Zip Page 1 of 6 L Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace> 100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator 4 Air Handling Unit <10,000 CFM ) — Comm/Ind omm Other Mechanical Equipment MECHANICAL PERMIT INFORMATION - 206 -431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: OA c 1 0 r\a,1 y\ ei Mailing Address: — 1 - 1 "1 "CD A V Contact Person: YG-- f -..L� S E -Mail Address: Contractor Registration Number: i\ \ tt O PS 9 $D Ku Valuation of Project (contractor's bid price): $ 1 - -- )q 2- J Scope of Work (please provide detailed information): s - �' <7 1) ) IC � b Qom. � - o (? c -F 4. A C uL . �� `"'' Li ct.u. c, -- e r1 \-.) �' X s n a, c r k_ . n t) Use: Residential: Commercial: Fuel Type: Electric New .... ❑ New ... ❑ Indicate type of mechanical work being installed and the quantity below: O'Applicntions.Forms- Applications On L4n0-2006. Yemtit Application,doc Revised: 4 -2006 bh Sw w+A gglo(c. City State Zip Day Telephone: C L) t=) i„c — ck 0 L. Fax Number: b — 3 Expiration Date: 1 a.-" 31 —' Replacement .... ❑ Replacement ....1S1 Gas .... Other: Page 4 of 6 BUILDING Signature: Date Application Accepted: PERMIT APPLICATION NOTES — Applicable to all permits in this Application' Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. THORIZED AGENT: Print Name: D Vk Day Telephone: C � c -) Mailing Address: ' 1 \ ' .kro It PRA-R. S 1,4.J •CN t 2( 0 0/0 tc-I 9'1 QdApplivetionaV'orma- Applications Oa LS11 0.2006 - Permit APRlication.doc Revised: 4 -2006 bh Date: City State Zip Date Application Expires: a 112 01 Staff Initials: / 1 Page 6 of 6 Parcel No.: 0923049031 Permit Number: M08 -228 Address: 12101 TUKWILA INTERNATIONAL BL TUKW Status: PENDING Suite No: Applied Date: 09/12/2008 Applicant: DIGITAL FOREST, UPS ROOM Issue Date: Receipt No.: R08 -03242 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Initials: JEM Payment Date: 09/12/2008 11:43 AM User ID: 1165 Balance: $0.00 Payee: MACDONALD- MILLER FACILITY SOLUTIONS, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1858 372.50 ACCOUNT ITEM LIST: Description rtnn: Rarnint -f1R MECHANICAL - NONRES PLAN CHECK - NONRES Account Code Current Pmts 000.322.102.00.0 298.00 000/345.830 74.50 Total: $372.50 Payment Amount: $372.50 7221 09/12 ?707 TCTAL Printarl • (1A- 12 -2flOA Steve Flink Ac�° unt itAB -------- MicD'onald- Miller Facility Solutions 2500 South Holgate ' r - Tacoma, WA 98402 Mr. Flink: Sincerely, Ben Fisher Project Engineer Poggemeyer Design Group Phone: (425) 827 -5995 Fax: (425) 828 -4850 Enclosed: SK -1 CC: Poggemeyer File POGGEMEYER DESIGN GROUP titViE�� O NCE CODE APPROVED SEP 2 4 2008 City Of itukviiia RE: Digital Forest UPS Room RTU, Roof Capacity Verification for Proposed HVAC Unit Installation We have reviewed the loading effects of the proposed Trane Voyager TCD -180 mechanical unit, which has a maximum operating weight of 2,000 lbs., which will be located on the roof of Intergate West Building "C" between grids A -B, bay 2 -3, as shown per attached sketch SK -1. The unit shall be installed with the accessory-roof curb in order to more effectively distribute the weight of the structure to the two joists. Our review of the proposed HVAC unit included analysis of gravity loads and possible seismic lateral loading, as determined per the International Building Code (2006 Edition) and the ASCE 7 -05 codes. We have determined that the roof has sufficient capacity to support the loading demands imposed by the proposed unit. Please feel free to call me at (425) 827 -5995 for any further question or clarifications. August 22 2008 RECEIVED CITY OF TUKWILA SEP: 12 `2008 PERMIT CENTER mos- 1_21 512 6th Street South, Suite 202 I Kirkland, Washington 98033 I P 425.827.5995 I www.poggemeyer.com a OGGEMEYE'. ".. IGN GROUP Cons,�,1 {alseers � No i :. r . ion 512 6th Street So. ite 20" • Kirkland, WA 9ou33 (425) 827 —'' "9 • FAX ( 4850 Made by BSF Date 8/1 2/08 Job No. 8035 Checked by Date Sheet No. SK - Description TRANE VOYAGER TCD -180 HVAC ATTACHMENT Job Name DIGITAL FOREST ROOF TO ROOF AT INTERGATE WEST BLDG C 200E ° a' .. ° . of .. ° ,. �, ... ®.. ' 9_ � 4 1 . , TAV - 1 ,MI , sub A "<:,& r, � = I � W■ III Ni — ' E • 7 0 I ' ; _I 1 1 117 H A UNIT ENLARGED AREA UPS ROOM AT Q 15'— OMEN TRANE HVAC UVIT TTACHMNT TO RCOF PER MANUFACTUPER BLDG C ROOF PLAN ' -11" 0'— TRANS _ VOYAGGER. � u; ; TCD. = 180 >4 z ; .; (20 L'_BS): ROOF ARE HVAC OVER UPS ROOM o SCALE: 1/8" = 1' -0" N SCALE: NTS 3'— 0 8035— S1.0'WG POGGEMEYER DESIGN GROUP CONSULTING ENGINEERS 512 Sixth Street South, Suite 202 • Kirkland, WA 98033 425 827 -5995 • Fax 425 828 -4850 i i i i Made by 135r � Date Z 0 8 $ I Job No. Checked by Date Sheet No. Description U94 1 "Vir Job Name D I A- t•1'l/.�I - i°ID A. eSr e,GNe. ^+t lc- De i tt pi GA o7fs e r f NJtG Gteon06 "T �AeJ Jb7 C4M— ie , igo EK-!N`1(i pF,S(tn fo11.4a Cgf( It ' ) ZtP < 14/fblf rAo,t6 1 -I t . ($.3 -1 fa. l3. • 66 t. 1 g.3 - Voyager TCD Items: AC-1 Oty 1 Tees: AC-1 V3020001:1T:30PM etc. 2. ' � b• ft, -0 0• a p ' Sos • W e C ILP / z r loAO (o rA 6te-%Rtd 5 0 A tt .qhM ± 0.2-4vs Wp t'e ‘ - 0.111 5 01- 0.0)6 DOWNFLOW ISOMETRIC-PACKAGED COOLING WITH ELECTRIC HEAT OIghh Fonal A =1 .o re, ` l•�•So4 If•L . 1 l 9 (0411-y.) p O. i • Wr / $loll (t`'t'^)) TRANE )2' OM HOLE (UNIT CONTROL WIRE) PE (k J c T r'. . POGGEMEYER DESIGN GROUP CONSULTING ENGINEERS 512 Sixth Street South. Suite 202 • Kirkland. WA 98033 (425) 827 -5995 • Fax (425) 828 -4850 Made by 7.51- S[a Date 41ttiioe Job No. Checked by Date Sheet No. Description OPh (1.110M tt.AJh v Job Name pi A NT)gv F-,s w,1 �i ff A 14 pzer(Ari o.LSO� tut tP' TrALIA is f F wet to.Lti HOti4tfw r ockno AT g QR9. OF w= q1'' Q ° Iva" k- gro" �Illb< (1000 ") - (letoP)(3G") t (t to -I2C 4,41:. ' ( ti °IUD (1 i yop lieu Fr ?(" t I oW" ) '2 i — (ni'*X 6q14): f it q((° 04.1e9 vp Me 6a�o,h - ( - br." VPLI 104 Mai uktf1 c tioo vPUt •rr I ife r, µRX Ovw 5°lD pvw r( ( X00 41 /Farr D65t4u --$ r oa- e S fen, fart D tti4c r 4NeRWn- I evy° ( 2`7O /ivbr� 1 0 t t o•^^►"' J pj y i f (00 It POW N POGGEMEYER DESIGN GROUP f Made by D Date a J Job No. Checked by D Date S Sheet No. Description v4 s P- 4t9M rt JnrL Job Name pmt Pow-4r e e,gtc ^4.Lvf 4 aJ l ' t 04 e tc ( lc OEC* 6 k A-I I t( ne n ( 11 (, . ttiva 1456 wu'- C 4it,co) 'y4" 6K. 194 I) tide t,os EA. NI KvWf 1 114 (701 wed ylOE Lift fS it'T VI d G. Cot A- ktA.--4AAA. VA t.v6S t >w M- r Ny t / % (Ice S Pi - art I:l ai c -C* t. F ('t''-' q vurvv a P) t VrJ I poNM t.vM X �,t�Meys Lgco 46F ? t1NIf $ '(v{o PPF. - I5 F S '5L /tose.s:r• Poor* Demo A ooavPrt13 \J11(44,? f1 (i11 a.t. 4f n ,.r s 1a1•ti a 1O'n. GoftQ° Yq3 fur u4E 14A4 - *i$4 eur (her f t 0 ' 2C (' r) % 5 r' ' Gr) ?XO f(X- F po JDlyt4 MOB 466 merettcq G �1.G9 • Linf4I Loads: LC 1, LC- DESIGN Results for LC 1, LC- DESIGN Member Bending Moments (k -ft) Reaction units are k and k -ft oggemeyer Design Group BSF .X - .493k/ft 4.8 4.8 -23.4 Design Load Diagram Aug 12, 2008 at 11:52 AM 16K4 TEST.r2d Beam. ryMI Shape: RE4X4 Material: gen_Conc3NW _ength: 19.5 ft I Joint: N1 J Joint: N2 LC 1: LC- DESIGN Code Check: 0.000 (bending) Report Based On 97 Sections fa ksi 26.362 at 9.75 ft ksi - 26.362 at 9.75 ft ksi A k V 4.807 at O ft -4.807 at 19.5 ft k - 23.433 at 9.75 ft k -ft D - 23.829 at 9.75 ft in Loads: LC 2, LC- PROPOSED Results for LC 2, LC- PROPOSED Member Bending Moments (k -ft) Reaction units are k and k -ft oggemeyer Design Group BSF -13.8 PROPOSED LOAD CASE Aug 12, 2008 at 11:52 AM 16K4 TEST.r2d Beam: MI Shape: RE4X4 Material: gen_Conc3NW _ength: 19.5 ft I Joint: N1 J Joint: N2 LC 2: LC- PROPOSED Code Check: 0.000 (bending) Report Based On 97 Sections fa ksi 15.502 at 8.938 ft - 15.502 at 8.938 ft ksi A k V 3 459 at 0 ft -2.625 at 19.5 ft k -13.78 at 8.938 ft k -ft - 14.176 at 9.547 ft in Voyager TCD Items: AC -1 Qty: 1 Tags: AC -1 6/30/2008 1:17:30 PM 50 1 /8" 6 5/8" DOWNFLOW CONDENSATE DRAIN CONN 1" NPT 4 1/4" 25 1/2" L 4 1/4" 106 11/16" SERVICE GAUGE PORT ACCESS 18 11/16" 22 1/7' THROUGH THE BASE ELECTRICAL (SEE ACCESSORY SHEET Digital Forest TI 26 7/16" DOWNFLOW - PENATRATION 70 13/16" 2" DIA HOLE (UNIT POWER WIRE) DOWNFLOW ISOMETRIC - PACKAGED COOLING WITH ELECTRIC HEAT 62 7/16" RETURN 54 11/16" SUPPLY TRAM" 7/8" DIA. HOLE (UNIT CONTROL WIRE) TOPSS Dimension Drawing ALL ELHTS AND DIIENSDNS ARE APPROXPIATE. CERTFED PRNTS ARE AVAIABLE UPON REQUEST. Page: 1 GENERAL Tons: 15 Unit Operating Voltage Range: 414 -506 Unit Hertz: 60 Unit Primary Voltage: 460 Unit Phase: 3 Unit Secondary Voltage: - EER: 9.9 Standard Motor Oversized Motor Field Installed Oversized Motor Minimum Circuit Ampacity: 39.0 Minimum Circuit Ampacity: 42.0 Minimum Circuit Ampacity: N / A Maximum Fuse Size: 50.0 Maximum Fuse Size: 50.0 Maximum Fuse Size: N / A Maximum (HACR) Circuit Breaker: 50.0 Maximum (HACR) Circuit Breaker: 50.0 Maximum (HACR) Circuit Breaker: N / A HEATER Heater kW Rating: N / A Standard Motor with Heat Stage N / A Oversized Motor Field Installed Oversized Motor Minimum Circuit Ampacity: N / A Minimum Circuit Ampacity: N / A Minimum Circuit Ampacity: N / A Maximum Fuse Size: N / A Maximum Fuse Size: N / A Maximum Fuse Size: N / A Maximum (HACR) Circuit Breaker: N / A Maximum (HACR) Circuit Breaker: N / A Maximum (HACR) Circuit Breaker: N / A COMPRESSOR OUTDOOR MOTOR Circuit #1 Circuit #2 Number: 1 Number: 1 1 Horsepower: .50 Horsepower: 9.3 5.1 Motor speed (RPM): 1,100 Phase: 3 3 Phase: 3 Rated Load Amps: 16.3 10.0 Full Load Amps: 1.6 Locked Rotor Amps: 113.0 63.0 Locked Rotor Amps: 3.8 INDOOR MOTOR Standard Motor Oversized Motor Field Installed Oversized Motor Number: 1 Number: 1 Number: N / A Horsepower: 3.0 Horsepower: 5.0 Horsepower: N / A Motor Speed (RPM): 1,740 Motor Speed (RPM): 3,450 Motor Speed (RPM): N / A Phase: 3 Phase: 3 Phase: N/A Full Load Amps: 4.8 Full Load Amps: 7.6 Full Load Amps: N / A Locked Rotor Amps: 40.5 Locked Rotor Amps: 54.9 Locked Rotor Amps: N / A POWER EXHAUST ACCESSORY FILTERS REFRIGERANT (Field Installed Power Exhaust) Type: R -22 Horsepower: N / A Type Throwaway Factory Charge Motor Speed (RPM): N / A Fumished: YES Phase: N / A Number: 2 / 4 Circuit #1: 17.5 lb Full Load Amps: N / A Recommended Size: 20" x 20" x 2" / 20" x 25" x 2" Locked Rotor Amps: N / A Circuit #2: 9.5 lb Voyager TCD items: AC -1 Qty: 1 Tags: AC -1 6/30/2008 1:17:31 PM Digital Forest TI ELECTRICAL / GENERAL DATA NOTES: 1. Maximum (HACR) Circuit Breaker sizing is for installations In the United States only. 2. Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions. 3. Value does not include Power Exhaust Accessory. 4. Value includes oversized motor. 5. Value does not include Power Exhaust Accessory. 6. EER is rated at ARI conditions and in accordance with DOE test procedures. TOPSS Dimension Drawing ALLW ELHTS AND DE1 ENSDNS ARE APPROXIMATE. CERTFED PRINTS ARE AVAIABLE UPON REQUEST. Page: 2 Voyager TQD items: AC -1 Qty: 1 Tags: AC -1 6/30/2008 1:17:31 PM 50 1/8" 6 5/8" DOWNFLOW CONDENSATE DRAIN CONN 1" NPT SINGLE POINT POWER ENTRY 4 1/4" 48 3/8" 106 11/16" SERVICE GAUGE PORT ACCESS Digital Forest TI 70 13/16" 2" DIA HOLE (UNIT POWER WIRE) DOWNFLOW ISOMETRIC - PACKAGED COOLING WITH ELECTRIC HEAT J 62 7/16" RETURN 54 11/16" SUPPLY 0 4 1/4" L 18 11/16" 22 1/2" 26 7/16" DOWNFLOW - PENATRATION elft maw 7/8" DIA. HOLE (UNIT CONTROL WIRE) TOPSS Dimension Drawing ALL ELHTS AND DIMENSDNS ARE APPROXIMATE. CERTFED PRINTS ARE AVAIABLE UPON REQUEST. Page: 3 ACCESSORY WEIGHTS ECONOMIZER 65.0 Ib MOTORIZED OUTSIDE AIR DAMPER MANUAL OUTSIDE AIR DAMPER HEATER OVERSIZED MOTOR 5.0 Ib HIGH STATIC DRIVE HIGH EFFICIENCY MOTOR (FIOPS) THROUGHT THE BASE ELECTRICAL (FIOPS) UNIT MOUNTED CIRCUIT BREAKER (FIOPS) UNIT MOUNTED DISCONNECT (FIOPS) POWERED CONVENIENCE OUTLET (FIOPS) HINGED DOORS (FIOPS) TOOL -LESS HAIL GUARD (FIOPS) POWER EXHAUST ROOF CURB 205.0 Ib BASE UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITIY' SHIPPING NET O 547.0 Ib © 234.0 Ib (E) LENGHT (F) WIDTH 1866.0 lb 1498.0 Ib O 358.0 Ib DO 359.0 Ib 42• • 28" Voyager TCD Items: AC -1 Qty: 1 Tags: AC -1 6/30/2008 1:17:32 PM CORNER WEIGHT Digital Forest TI MINE' INSTALLED ACCESSORIES NET WEIGHT DATA RIGGING AND CENTER OF GRAVITY NOTE: 1. CORNER WEIGHTS ARE GIVEN FOR INFORMATION ONLY. 2. TO ESTIMATE SHIPPING WEIGHT OF OPTION /ACCESSORIES ADD 5 LBS TO NET WEIGHT. 3. NET WEIGHT OF OPTIONAL ACCESSORIES SHOULD BE ADD TO UNIT WEIGHT WHEN ORDERING FACTORY INSTALLED ACCESSORIES. 4. WEIGHTS FOR OPTIONS NOT LISTED ARE < 5 LBS. 5. WEIGHT ARE OF BASE UNIT ONLY. FOR TOTAL WEIGHT, 10 DIGIT FACTORY INSTALLED OPTION (ECONOMIZER AND /OR OVERSIZED MOTOR OR FIOP /ACCESSORY WEIGHT MUST BE ADDED. TOPSS Dimension Drawing ALLW ELHTS AND D]IENSDNS ARE APPROXIMATE. CERTFED PRNTS ARE AVA1ABLE UPON REQUEST. Page: 4 Voyager TCD items: AC -1 Qty: 1 Tags: AC -1 6/30/2008 1:17:33 PM CLEARANCE 68" UNIT OUTLINE CLEARANCE 60" Digital Forest TI CLEARANCE 36" DOWNFLOW - PACKAGED COOLING WITH ELECTRIC HEAT CLEARANCE CLEARANCE 48" 62 1/2" DOWNFLOW- PACKAGED COOLING WITH ELECTRIC ROOF OPENING CLEARANCE A TRAIN" W TOPSS Dimension Drawing ALLW ELHTS AND DE ENSDNS ARE APPROXIMATE. CERTFED PRNTS ARE AVALABLE UPON REQUEST. Page: 5 Voyager TQD !tams: AC -1 Qty: 1 Tags: AC -1 6/30/2008 1:17:33 PM 66 Digital Forest TI 101 7/8" ACCESSORY -ROOF CURB 14 1/16" ACCESSORY - DOWNFLOW DUCT CONNECTIONS TRAiVE" TOPSS Dimension Drawing ALL ELHTS AND D31 ENSDNS ARE APPR0XMIATE. CERTFED PRNTS ARE AVAIABLE UPON REQUEST. Page: 8 2" zt 'ft1 �5I" 6 7 1 13/16" — - 113/16" 20 7/8" 1," 17 1/8" = 28 1/2" —� 1" 1" 1 63" 5/8" r. 7 RETURN 55 SUPPLY 1/2" L 11 1 n 9 1 / 4 1 " Voyager TQD !tams: AC -1 Qty: 1 Tags: AC -1 6/30/2008 1:17:33 PM 66 Digital Forest TI 101 7/8" ACCESSORY -ROOF CURB 14 1/16" ACCESSORY - DOWNFLOW DUCT CONNECTIONS TRAiVE" TOPSS Dimension Drawing ALL ELHTS AND D31 ENSDNS ARE APPR0XMIATE. CERTFED PRNTS ARE AVAIABLE UPON REQUEST. Page: 8 Voyager TCD Items: AC -1 Qty: 1 Tags: AC -1 6/30/2008 1:17:35 PM Digital Forest TI TRAM' N TOPSS Dimension Drawing ALL ELHTS AND D]M ENSDNS ARE APPROXt1ATE. CERTFED PRNTS ARE AVAILABLE UPON REQUEST. Page: 7 Dimensional Data Figure 9. Cooling with Optional Electric Heat and Gas /Electric Models - 12 -17 Tons Standard Efficiency; 12 Tons High Efficiency * All dimensions are in Inches /millimeters. "1/2 NPT Gas Connection = (Y_C Models only); 2" Electrical Connection: Single Point Power When Heat Installed (T_C Models only.) FILTER ACCESS DOOR HORIZONTAL OOWNFLOW CONDENSATE DRAIN CONN 1" (25.4MM) NPT SINGLE POINT POWER ENTRY .50 (12.3MM) NPT GAS INLET (VC'180 -H - .75 (19.05MM) NPT) (YC'210 -H - .75 (19.05MM) NP 71 5/8" 1819.28MM 106 11/16" 2709.87MM VC' MODELS ONLY 107 5/16' 2725.74MM 70 13/16' 1798.64MM 2' (50.80MM) DIA HOLE (UNIT POWER WIRE) 50 1/8" 1273.18MM 7l8' (22.23MM) DIA. HOLE (UNIT CONTROL WIRE) SERVICE GAUGE PORT ACCESS 116 RT- PRCO24 -EN 02 -02 -2009 JARED SHEEKS 7717 DETOIT AV SW SEATTLE WA 98106 RE: Permit No. M08 -228 12101 TUKWILA INTERNATIONAL BL TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 03/28/2009 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician xc: Permit File No. M08 -228 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 DEPARTMENTS: B il• ngD'YJSt'on Public Works Comments: Documents/routing slip.doc 2 -28-02 • PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M08 -228 DATE: 09 - - PROJECT NAME: DIGITAL FOREST, UPS ROOM SITE ADDRESS: 12101 TUKWILA INTERNATIONAL BL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued 611 AN 141 Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUT NG: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 09-16-08 Not Applicable ❑ No further Review Required DATE: DUE DATE: 10-14-08 Not Approved (attach comments) DATE: Planning Division Permit Coordinator n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Name Role Effective Date Expiration Date TURLEY, DOUGLAS CHIEF EXECUTIVE OFFICER 02/13/2008 Bond Amount TURLEY, DOUGLAS CHIEF OPERATING OFFICER 02/13/2008 023006951 SIGMUND, FREDRIC PRESIDENT 12/31/2002 HACK, RICHARD SECRETARY 02/13/2008 KOPET, TYLER TREASURER 12/31 /2002 LOVELY, STEVE C VICE PRESIDENT 12/31/2002 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 LIBERTY MUTUAL INS CO 023006951 12/11/2002 Until Cancelled $12,000.00 12/31/2002 Insurance Company Name policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 7 TRAVELERS INDEMNITY DTCO526D7513INDO7 12/31 /200712/31 /2008 $1,000,000.00 12/21 /2007 Untitled Page General /Specialty Contractor A business registered as a construction contractor with LEtI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County MACDONALD /MILLER FAC SOL INC 2067684180 PO BOX 47983 SEATTLE WA 98106 KING Business Type CORPORATION Parent Company UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 602254260 ACTIVE MACDOFS980RU CONSTRUCTION CONTRACTOR 12/31/2002 12/31/2008 DIVCOEC188LC GENERAL UNUSED Business Owner Information Bond Information Insurance Information • • https: / /fortress.wa. gov /lni/bbip/Detail. aspx ?License= MACDOFS980RU Page 1 of 2 09/29/2008 f=e) MacDonald- Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206 - 763 -9400 Fax: 206 - 767 -6773 www•macmiller.com WA Lic No: MACDOFS980RU T i.. k !WAS' 3616 a ' ' s GI ST � 1�c, S �ONAL A 1 EXPIRES: 07 -06 -10 1 1/2 HOUR CURTAIN STYLE VERTICAL FIRE DAMPER GREENHECK DFD 150 OR EQUAL 1 1/2 HOUR CURTAIN STYLE HORIZONTAL FIRE DAMPER tf � � a s vk., �xi,. x .roc - . '•- MAR 2 8 2009 k VIEWED FOR _ - - DE COMPLIANCE - APPROVED - - SEP 2 4 2008 - City Of Tukwila ' - - II-DIN PIVIS RECEIVED CITY OF TUKWILA - SEP, 12 2008 - PERMIT CENTER - REVISIONS: DATE DIGITAL FOREST DATA CENTER EXPANSION RTU -1 ADDITION 12101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA SCHEDULES & NOTES - HVAC GREENHECK CFSD 212 -1 OR EQUAL FSD 3 HOUR VERTICAL COMBINATION FIRE /SMOKE ENGINEER: LAST REVISED: J SHEEKS 09 -12 -08 CHECKED BY: DATE PLOTTED: B CEZON 09 -12 -08 CAD: ISSUE DATE: J SHEEKS DRAWING NUMBER: c 1 490 - 7386578 -00 -00 ISSUED FOR PERMIT SHEET NUMBER: T MO.O1 DAMPER LEGEND SYMBOL DESCRIPTION- POWERED SYMBOL DESCRIPTION -NON POWERED 1 1/2 HOUR VERTICAL COMBINATION FIRE /SMOKE FSD 40 FD HFD FD • HFD • FD • BDD 1 1/2 HOUR CURTAIN STYLE VERTICAL FIRE DAMPER GREENHECK DFD 150 OR EQUAL 1 1/2 HOUR CURTAIN STYLE HORIZONTAL FIRE DAMPER GREENHECK FSD 212 (2000 FPM) OR EQUAL GREENHECK FSD 312 (3000 FPM) OR EQUAL 1 1/2 HOUR HORIZONTAL COMBINATION FIRE /SMOKE HFSD 400 GREENHECK OR GREENHECK DFD 150 (HORIZONTAL MOUNT) OR EQUAL 3 HOUR CURTAIN STYLE VERTICAL FIRE DAMPER FSD 212 (2000 FPM) EQUAL GREENHECK FSD 312 (3000 FPM) OR EQUAL TFSD 4> 1 1/2 HOUR TUNNEL CORRIDOR COMBINATION FIRE /SMOKE GREENHECK DFD 350 OR EQUAL 3 HOUR CURTAIN STYLE HORIZONTAL FIRE DAMPER GREENHECK CFSD 212 -1 OR EQUAL FSD 3 HOUR VERTICAL COMBINATION FIRE /SMOKE GREENHECK DFD 350 (HORIZONTAL MOUNT) OR EQUAL CEILING RADIATION DAMPER GREENHECK FSD 231 OR EQUAL HFSD © 3 HOUR HORIZONTAL COMBINATION FIRE /SMOKE GREENHECK CRD -2 OR EQUAL BACKDRAFT DAMPER GREENHECK FSD 231 OR EQUAL SMOKE DAMPER BAR 05 I GREENHECK WD 330 (VERT) OR WD -100 (HORIZONTAL) OR EQUAL $\\ BAROMETRIC RELIEF DAMPER (.05 OPNG PRESSURE SHOWN) SD GREENHECK SMD 202 OR EQUAL MD © MOTORIZED CONTROL DAMPER BUSKIN CBD2 NO SUBSTITUTE ALLOWED VOLUME DAMPER GREENHECK VCD -23 OR EQUAL SMOKE CONTROL MOTORIZED DAMPER GREENHECK SMD 301 OR EQUAL SHOP FABRICATED, W/ LOCKING QUADRANT SCD 4 0 INTERLOCK WITH FIRE ALARM BY ELECTRICAL CONTRACTOR ACCESS DOOR AD > 18" x 18" MINIMUM THROUGH BUILDING CONSTRUCTION BY GENERAL CONTRACTOR GENERAL NOTES: COMBINATION FIRE /SMOKE DAMPER REQUIREMENTS (UNLESS OTHERWISE NOTED): - CLASS II - 165° FUSIBLE LINK - FAIL - CLOSE, 120V ACTUATOR - ACTUATOR BY MECHANICAL CONTRACTOR, WIRING BY ELECTRICAL CONTRACTOR - INTERLOCK TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR FIRE DAMPER REQUIREMENTS: - BLADES OUT OF AIRSTREAM ON MEDIUM PRESSURE DUCTS - 165 F FUSIBLE LINK - CLASS 11 DUCT LEGEND DESCRIPTION SYMBOL DESCRIPTION SYMBOL BARE SHEETMETAL EXH FAN ROUND SHEETMETAL WRAPPED W/ INSULATION (2 ") EER/ IPLV 1 4/1 2 1 20W NOTES CFM SOUNDLINE SHEETMETAL (1" LINING) QTY CLEANROOM QUALITY DUCTWORK QTY 1 4/1 2 SL 1 4/1 2 0 HP VOLT /PH SHEETMETAL WRAPPED W/ INSULATION (2 ") AC -1 BARE FLAT OVAL SHEETMETAL 75 14/12 W 14/12& 2 BARE ROUND SHEETMETAL 2 FLAT OVAL FLAT SHEETMETAL W/ INSULATION (2 ") 6 120 14/128W 460/3 EXPOSED QUALITY SHEETMETAL 1 DUCTBOARD (1" FIBERGLASS) AAON RN -070 1 4/1 2 Q 14/12 DB 2 2 EXAMPLE OF NEW 1000 EXAMPLE OF NOT IN CONTRACT (NIC) - ___.I `tI2 1 4/1 2 3/4 EXAMPLE OF DEMO 460/3 FLEX DUCT 7000 x x x x x x x x x x x x x x EXAMPLE OF EXISTING 70 FLEX CONNECTOR 2 1 4/12 j i 1000 2 1 PACKAGED ELECTRIC AIR CONDITIONING SCHEDULE UNIT NO. MFG & MODEL NO. NOM TONS SUPPLY FAN OA CFM EXH FAN COND FAN EER/ IPLV ELECTRICAL WT LBS NOTES CFM ESP QTY HP QTY HP QTY HP VOLT /PH MCA AC -1 TRANS SXHFC75 75 2 2 20 6 1 460/3 11000 1 AC -2 AAON RN -070 70 25000 2 2 15 1000 2 3 6 3/4 9.4/10.1 460/3 15 7000 1 AC -3 AAON RN -070 70 25000 2 2 15 1000 2 3 6 3/4 9.4/10.1 460/3 157 7000 1 AC -4 AAON RN -070 70 25000 2.0 2 15 1000 2 3 6 3/4 9.4/10.1 460/3 157 7000 1 AC -5 AAON RN -070 70 25000 2.0 2 15 1000 2 3 6 3/4 9.4/10.1 460/3 157 7000 2 RTU -1 TRANE TFD -180 15 6000 1.0 1 5 200 - - 2 1/2 9.9/10.2 460/3 42 2000 3 NOTES: 1. EXISTING ROOFTOP AIR CONDITIONING UNIT TO REMAIN. 2. FUTURE ROOFTOP PACKAED AIR CONDITIONING UNIT. 3. NEW ROOFTOP PACKAGED AIR CONDITIONING UNIT WITH THE FOLLOWING FEATURES /ACCESSORIES: R -22 REFRIGERANT (2) SCROLL COMPRESSORS 100% ECONOMIZER WITH BAROMETRIC RELIEF ACCESSORY (CANFAB 6107 -EC). RETURN AIR SMOKE KE DETE C T R - CONNECTION T O FIRE ALARM SYSTEM BY ELECTRICAL NTRA U S O C O O S S CONTRACTOR FACTORY MOUNTED DISCONNECT - ELECTRICAL CONNECTION BY ELECTRICAL CONTRACTOR rj a SEPARATE N PERMIT REQUIRED tfiechanic r'Etectrica plumbing yeas piping City of - T DOING DIVISION REVISIONS No changes shall be made to © h el of scope cif work without prior app Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. Permit No. / Yy�R �t Mar review approval is suhl q I�g S. ,_ .-- .. t f f 8.7tructsor3 documents dDeS c.b ' � �' of approved t :field Copy the violation of any adopted coda or „, g �,. •i and conditions is acV.o� " :.: td: By + � � , Date: O l t i O0 Ti.Q' z 4 a ETW N DI ISIO S HVAC ABBREVIATIONS ABBV FULL NAME ABBV FULL NAME ABBV FULL NAME A AC AFF AL BDD BOB BOD BOTT BTU BTUH BWG BWR C CAP cC CFM CHWR CHWS COMB CONN CWR CWS DB DIFF DMPR DN EC EGC EER ELEV EMS COMPRESSED AIR LINE AIR CONDITIONING UNIT ABOVE FINISHED FLOOR ALUMINUM BACKDRAFT DAMPER BOTTOM OF BEAM BOTTOM OF DUCT BOTTOM BRITISH THERMAL UNITS BRITISH THERMAL UNITS PER HOUR BOTTOM WALL GRILLE BOTTOM WALL REGISTER CONDENSATE CAPACITY CONTROLS CONTRACTOR CUBIC FEET PER MINUTE CHILLED WATER RETURN CHILLED WATER SUPPLY COMBUSTION CONNECT CONDENSER WATER RETURN CONDENSER WATER SUPPLY DUCT BOARD DIFFUSER DAMPER DOWN ELECTRICAL CONTRACTOR EGGCRATE ENERGY EFFICIENCY RATIO ELEVATION ENERGY MANAGEMENT SYSTEM ESP EXH EXTR FAC FD FLA FOB FOT FSD G GALV GC GPM GR GWB HG HP HWR HWS ID I NT LIQ M -M MBH MC MCA MD MIN MT MUA NOM EXTERNAL STATIC PRESSURE EXHAUST EXTRACTOR FIRE ALARM CONTRACTOR FIRE DAMPER FULL LOAD AMPS FLAT ON BOTTOM FLAT ON TOP FIRE SMOKE DAMPER GAS LINE GALVANIZED GENERAL CONTRACTOR GALLONS PER MINUTE GRILLE GYPSUM WALL BOARD HOT GAS LINE HORSE POWER HOT WATER RETURN HOT WATER SUPPLY INSIDE DIMENSION INTERLOCK LIQUID LINE MACDONALD - MILLER ONE THOUSAND BTUH MECHANICAL CONTRACTOR MINIMUM CIRCUIT AMPACITY MOTORIZED DAMPER MINIMUM MOUNT MAKE -UP AIR NOMINAL OSA OBD OD RA REG REQ'D RIO SA SCD SD SL SM SP SS SSSC STL SUC SUSP T'STAT THERMOSTAT TC TOD TOS TV TWG TAR TYP UND VD VFD OUTSIDE AIR OPPOSED BLADE DAMPER OUTSIDE DIMENSION RETURN AIR REGISTER (GRILLE WITH DAMPER) REQUIRED ROUGH IN ONLY SUPPLY AIR SMOKE CONTROL DAMPER SMOKE DAMPER SOUND LINING SHEET METAL STATIC PRESSURE START /STOP SOLID STATE SPEED CONTROLLER STEEL SUCTION LINE SUSPENDED TEMPERATURE CONTROL TOP OF DUCT TOP OF STEEL TURN VANES TOP WALL GRILLE TOP WALL REGISTER TYPICAL UNLESS NOTED OTHERWISE VOLUME DAMPER VARIABLE FREQUENCY DRIVE VOLTAGE PHASE & DUCT DIAMETER NAME TITLE TM0.01 SCHEDULES -HVAC TM2.04 4TH FLOOR PLAN - HVAC TM2.05 ROOF FLOOR PLAN - HVAC CONTACT LIST TITLE PROJECT ENGINEER ACCOUNT EXECUTIVE SHEET METAL FOREMAN NAME JARED SHEEKS STEVE FLINK LARRY HARBISON DRAWING SHEET INDEX COMPANY NAME TITLE MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER PHONE NUMBER 206 -768 -3806 253 -680 -3172 206-768 -4294 E - MAI L jared.sheeks(G,macmiller.com steve.flink @macmiller.com larry.harbison @macmiller.com SCOPE OF WORK UPS ROOM ROOFTOP UNIT ADDITION: PROVIDE AND INSTALL (1) 15 TON TRANE VOYAGER PACKAGED ROOFTOP AIR CONDITIONER. MOUNT UNIT ON FACTORY CURB. INSTALL ASSOCIATED SUPPLY AND RETURN DUCTWORK WITH SUPPLY DUCTWORK TO TIE INTO EXISTING DUCTWORK. INSTALL (1) COUNTER - BALANCED BACKDRAFT DAMPER IN SUPPLY DROP FROM RTU. INSTALL (1) MOTORIZED CONTROL DAMPER IN EXISTING SUPPLY DUCTWORK TO PREVENT BACKFLOW WHEN RTU -1 IS OPERATING. INTERLOCKING OF DAMPER WITH SUPPLY FAN OF RTU IS BY CONTROLS CONTRACTOR. CONTROL OF ROOFTOP UNIT IS BY CONTROLS CONTRACTOR. HVAC GENERAL NOTES 1. THE HVAC SYSTEM FOR THIS PROJECT IS BASED ON THE FOLLOWING CRITERIA: ROOF "u" VALUE (BTUH /S.F. ° F) = N/A WALL "U" VALUE (BTUH /S.F. ° F) = N/A FLOOR "U" VALUE (BTUH /S.F. °F) = N/A GLASS "U" VALUE (BTUH /S.F. °F) = N/A GLASS SHADE COEFF. = N/A LIGHTING (WATTS /S.F.) = N/A MISC. EQUIP. (WATTS /S.F.) = N/A PEOPLE DENSITY (S.F./PERSON) = N/A COOLING INDOOR DESIGN TEMP (°F) = N/A COOLING OUTDOOR DESIGN TEMP ( °F) = N/A HEATING INDOOR DESIGN TEMP ( °F) = N/A HEATING OUTDOOR DESIGN TEMP ( °F) = N/A 2. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. MATERIALS METHODS AND INSTALLATION SHALL COMPLY WITH THE PR VI T E 2 ED T 3. I O SONS OF H 006 I IONS OF THE INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE AND STATE AND LOCAL CODES AND ORDINANCES. 4. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 6 OF THE 2006 IMC AND WITH CURRENT SMACNA STANDARDS. EARTHQUAKE BRACE ALL DUCTS 28" DIA AND LARGER WHICH ARE SUSPENDED MORE THAN 12" BELOW STRUCTURAL SYSTEM. 5. JOINTS OF MEDIUM AND HIGH VELOCITY DUCT SYSTEMS SHALL BE SEALED WITH GASKETS OR LISTED MASTIC TYPE DUCT SEALANT. 6. DUCTS SHALL BE INSULATED AS INDICATED ON PLANS, PER 2006 WSEC. - DUCT WRAP, WHERE INDICATED, SHALL BE 1 1/2" 0.75 LB /CU FT FIBERGLASS DUCT INSULATION WITH A FACTORY APPLIED REINFORCED ALUM. FOIL VAPOR BARRIER (R -4.2 MIN.). - SOUND LINING, WHERE INDICATED, SHALL BE 1" 1.5 LB /CU FT FIBERGLASS DUCT LINING COATED TO PREVENT FIBER EROSION AT VELOCITIES UP TO 6000 FPM (R-4.2 MIN.). - DUCT BOARD, WHERE INDICATED, SHALL BE 1" RIGID FRK FACED El 475 FIBERGLASS DUCT BOARD SYSTEM, UL 181 LISTED AS A CLASS 1 AIR DUCT (R-4.3 MIN.). 7. FLEX DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER, 1 1/2" FIBERGLASS INSULATION, AND NON - PERFORATED INTERIOR LINER WITH WIRE HELIX. DUCT SHALL BE A UL 181 LISTED CLASS 1 AIR DUCT. FLEX DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 8' IN LENGTH UNLESS NOTED OTHERWISE. 8. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 1621 OF THE 2006 IBC. 9. PROVIDE FIRE DAMPERS, SMOKE DAMPERS AND FIRE /SMOKE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.5 OF THE 2006 IBC. PROVIDE CEILING FIRE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.6.2 OF THE 2006 IBC. INSTALL FIRE DAMPERS SMOKE DAMPERS AND FIRE /SMOKE DAMPERS IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS, THE TERMS OF THEIR LISTING, AND THE REQUIREMENTS OF THE CODE. 10.PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 11.PROVIDE RETURN DUCT SMOKE DETECTOR AUTOMATIC SHUT DOWN OF ALL NEW HEATING, COOLING, OR VENTILATION EQUIPMENT MOVING IN EXCESS OF 2000 CFM IN ACCORDANCE WITH SECTION 606 OF THE 2006 IMC. POWER AND INTERLOCK WIRING WITH THE BUILDING FIRE ALARM SYSTEM IS BY THE ELECTRICAL CONTRACTOR. 12.HVAC EQUIPMENT, VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. 13.HEAT TRACING OF PIPING, WHERE INDICATED, SHALL BE PROVIDED AND INSTALLED BY THE HVAC CONTRACTOR. THE HVAC CONTRACTOR IS TO COORDINATE THE HEAT TRACE POWER WIRING WITH THE ELECTRICAL CONTRACTOR. 14.MOTOR STARTERS NOT LISTED AS BEING PROVIDED IN THE HVAC EQUIPMENT SCHEDULES ARE TO BE PROVIDED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. 15. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER. RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM, INCLUDING SIZES, AND THE TERMINAL AIR AND WATER DESIGN FLOW RATES. 16.OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE: SUBMITTAL DATA, NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY, HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM. 17.COMMISSIONING IS REQUIRED ON THIS PROJECT IN ACCORD WITH WASHINGTON S - ATE ENERGY CODE (WSEC) SECTION 1416 AND WITH LEED NC -2.1 FUNDAMENTAL BUILDING SYSTEMS COMMISSIONING AND ADDITIONAL COMMISSIONING. 18. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER. 19. FOR ALL "SEALED AIR TIGHT" SHAFTS OR ROOMS, THE FOLLOWING MUST OCCUR: - ALL VERTICAL JOINTS INSIDE THE SHAFT SHOULD BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT, INCLUDING THE SHAFT CORNERS (BY GC). - TOP AND BOTTOM WALL TRACKS SHOULD BE CAULKED ALONG THEIR ENTIRE LENGTH (BY GC). - ANY FLOOR DECKING PERPENDICULAR TO THE SHAFT SHOULD BE CAULKED. FILLING WITH ROCK WOOL OR FIRESAFING ( "MONOCOAT ") IS NOT ACCEPTABLE (BY GC). - ANY PENETRATIONS OF THE SHAFT CONSTRUCTION (DUCTWORK, CONDUIT, PIPING) SHOULD BE SEALED WITH FIRE CAULKING ON BOTH SIDES OF THE PENETRATION. - USE SECTION 909.5 OF THE 2006 IBC FOR MAXIMUM ALLOWABLE LEAKAGE AREA, FOLLOWING THE GUIDELINES FOR SMOKE BARRIER CONSTRUCTION. - ALL DOORS MUST BE PROVIDED WITH TIGHT FITTING GASKETS, AND OPEN AGAINST THE DIRECTION OF ROOM /SHAFT PRESSURE. 20.DAMPERS USED FOR OUTDOOR AIR INTAKE, EXHAUST, OR RELIEF SHALL HAVE THE FOLLOWING MAXIMUM LEAKAGE RATES AT 1" W.G. (PER AMCA STANDARD 500): MOTORIZED DAMPERS: 10 CFM /S.F. GRAVITY DAMPERS: 20 CFM /S.F. (40 CFM /S.F. FOR DAMPERS SMALLER THAN 24 INCHES IN EITHER DIMENSION). 21.OUTSIDE AIR INTAKE, EXHAUST, AND RELIEF DAMPERS SERVING CONDITIONED SPACES MUST BE MOTORIZED (FAIL CLOSED) PER WSEC 1412.4.1, EXCEPT AS ALLOWED BY WSEC. 22.RETURN AIR SHAFTS TO BE CONSTRUCTED BY THE G.C. TO WITHSTAND A MINIMUM 20 PSF DIFFERENTIAL PRESSURE ACROSS THE WALL. DIFFERENTIAL PRESSURE IS BASED UPON THE MAXIMUM STATIC PRESSURE CAPABILITY OF FAN SYSTEMS SUBJECT TO AUTOMATIC DAMPER CLOSURE. 23.PRESSURIZATION SHAFTS SHALL BE CONSTRUCTED BY THE G.C. AS FOLLOWS: SHAFTS SERVED BY PRESSURIZATION FANS RATED UP TO 1" STATIC PRESSURE TO BE CONSTRUCTED TO WITHSTAND 10 PSF DIFFERENTIAL PRESSURE. - SHAFTS SERVED BY PRESSURIZATION FANS RATED BETWEEN 1 -2.5" STATIC PRESSURE TO BE CONSTRUCTED TO WITHSTAND 20 PSF DIFFERENTIAL PRESSURE. - FOR SHAFTS SERVED BY PRESSURIZATION FANS RATED ABOVE 2.5" STATIC PRESSURE, CONTACT MECHANICAL ENGINEER. APN # 0923049309 LEGAL DESCRIPTION LEGAL DESCRIPTION: BEGIN NW CORNER OF NE 1/4 OF SE 1/4 TH S 89 -16 -35 E 100 FT TH S 24 -13 -53 E 567.42 FT TO POINT OF BEGINNING TH N 66 -35 -01 E 120.47 FT TH N 20 -23 -23 W 27.58 FT TH N 65 -32 -34 E 165 FT TO POINT ON WLY R/W LINE OF PRIMARY STATE HIGHWAY NO 1 (SR 99) SOUTH 118TH ST TO JCT SSH NO 1 -K APPROVED JULY 23, 1957 TH FOLLOWING SAID WLY RNV LINE 5 24 -27 -26 E 110.84 FT TH FOLLOWING SAID WLY R/W LINE N 65 -32 -34 E 10 FT TH FOLLOWING SAID WLY R/W LINE S 24 -27 -26 E 200 FT TH FOLLOWING SAID WLY R/W LINE N 65 -32 -34 E 20 FT TH FOLLOWING SAID WLY R/W LINE S 24 -27 -26 E 126 FT TH FOLLOWING SAID WLY R/W LINE ALONG ARC OF 2805 FOOT RADIUS NON TANGENT CURVE TO RIGHT CENTER BEARING S 65 -32 -34 W THRU C/A OF 0 -12 -18 DISTANCE OF 10.03 FT TH S 65 -30 -25 W 199.33 FT TH N 22 -47 -01 W 21.44 FT TH S 63 -32-48 W 62.13 FT TH 5 65 -46 -07 W 58.17 FT TH N 24 -13 -53 W 402.19 FT TO POINT OF BEGINNING LOT C OF CITY OF TUKWILA BOUNDARY LINE ADJUSTMENT NO L98 -0033 RECORDING NO 9810059013 12101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA SITE MAP NO SCALE MOg ��2g Q 0 a l a 00 rr) r-. 1 (1) 0 z w 0 a (!) TD z O 00 0 0 NEW CONTROL DAMPER L r EXISTING SUPPLY DUCTWORK 2.6/_54SL --5U PLY — UP IsTO ROy'F�f"OP: , UNI --- QU NTffR\ BALANCED KIN CBD -2, ISOMETRIC VIEW - HVAC SCALE: 1/2" = 1 -0" NEW MOTORIZED DAMPER GREENHECK VCD -23, FAIL OPEN INTERLOCK WITH RTU SUPPLY FAN (Y OTHERS) CONNECT TO EXISTING DUCT WITH ANGLE TAP 62/18SL RETURN DUCT UP TO ROOFTOP UNIT RETURN DUCT UP TO ROOFTOP UNIT COUNTER— BALANCED BACKDRAFT DAMPER SUPPLY DUCT UP TO ROOFTOP UNIT m.. (5) SCALE: 1 8 —0 4TH FLOOR PLAN HVAC (7.5 - r i 1 EX L_ ( A ey tog IAN'S CODE COMPLIANCE APPROVE SEP 2 4 2t1n Qty O uMtla BUI D 1 MAR 2 8 2009 RECEIVED CITY OF TUKWILA SEP 12 2008 PERMIT CENTER fr1OB CZ) MacDonald- Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206 - 763 -9400 Fax: 206 -767 -6773 www.macmiller.com WA Lic No: MACDOFS980RU 1 EXPIRES: 07 -06 -08 REVISIONS: DATE DIGITAL FOREST DATA CENTER EXPA \SIO\ RTU-1 ADDITIO\ 12101 TUKWILA INTL BLVD TUKWILA, WA 4TH FLOOR PLAN HVAC ENGINEER: LAST REVISED: J SHEEKS 09 -12 -08 CHECKED BY: DATE PLOTTED: B GEZON 09 -12 -08 CAD: ISSUE DATE: D IKERD DRAWING NUMBER: C- 1 490 - 7386342 -00 ISSUED FOR PERMIT SHEET NUMBER: TM2.04 0 0 0 N 2 N to Do M r-. z U) 0 z w 0 0 U- V) N) z 0 H w 0 Li J ft 0 A- M co N) w z W J 0 U 00 0 0 Ex's --- MAKE-UP AIR UNIT 26"0 DN 260 N HVU- 1 } (EXISTING) ACU-1 EXI ST ING ) NEW CONDENSATE LINE \ TO ROOF DRAIN 1Y2" PVC ' I 11 t EXIS 3/4"NPCW, CONNEC4 HUMT IFIER (TYP.) EXISTING SCREENWALL 1 1 \ I / I / I / 420 3/4"NPCW FROM - BELOW ROOF ---------- 48"0 NPCW ON THE ROVF. PROM D \ HEAT TAPE, INSUOTION `Y. WEATHER-PROO- JACKET 48"0 Dh„ EXITING ELECTRICAL PANELS \\ [7J r,..... ----- -------- il ( 3 ) EXISTING) ___ -{ Cu -1 1 (RELOCATED) r - CU-1] V ( EXISTING) 4 ) [11 __ ----- \ 1 \ 4 T. --- - EF- (EXISTING) FAG 3 I (EXISTING) AHU-3 (EXISTING) ROOF PLAN - HVAC SCALE: 1/8" =1 ROOFTOP STEEL SUPPORT rT STRUCTURE (SEE STRUCT DRAWINGS) (6 AFIU-12. EXISTI --- ---- _„ ITT ( 7 ) 7.5) 8"0 DU yr UP THRUf ROOF TO ROE CAP EF-2) MAR 2 6 2009 M '8 22 B RECEIVED CITY OF TUKWILA SEP 1 2 2008 PERMIT CENTER MacDonald-Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206-763-9400 Fax: 206-767-6773 www.macmiller.com WA Lic No: MACDOFS980RU I EXPIRES: 07-06-08 r REVISIONS: DATE DIGITAL FOREST DATA CENTER EXPANSION RTU-1 ADDITION 12101 TUKWILA INTERNATIONAL BLVD TUKWILA. WA ROOF PLAN HVAC ENGINEER: J SHEEKS CHECKED BY: B GEZON CAD: P MILLER LAST REVISED: 09-12-08 DATE PLOTTED: 09 - 1 2-08 ISSUE DATE: DRAWING NUMBER: • 1 49 0 - 7 38 6 342 - 00 ISSUED FOR PERMIT SHEET NUMBER: TM2.05 0 0 1-- 0 0 eL in I (.0 (0 N) 1- 1 (f) 0 0 0 z 0 0 u to CC z 0 U) LLI 0 LL b -C_D (NI v) co . . (Li z uJ 0