HomeMy WebLinkAboutPermit M08-236 - WALGREENS REFRIGERATIONWALGREENS
REFRIGERATION
3716 S 144 ST
M08 -236
Parcel No.:
Address:
Suite No:
Tenant:
Name:
Address:
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Contractor:
Name:
Address:
doc: I MC - 10/06
1523049140
3716S144STTUKW
City(if Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
WALGREENS REFRIGERATION
3716 S 144 ST , TUKWILA WA
TUKWILA HOLDINGS LLC
845 106TH AVE NE #100 , BELLEVUE WA
PAUL BREWER
2002 N FREMONT , TACOMA WA
ALPINE REF & HEATING INC
PO BOX 7464 , TACOMA WA
Contractor License No: ALPINRH027L6
MECHANICAL PERMIT
DESCRIPTION OF WORK:
INSTALL AND PIPE 22 FT WALK -IN COOLER AND (4) DOOR FREEZER AND PIPE TO BOTH
UNITS.
Value of Mechanical: $13,000.00
Type of Fire Protection:
Furnace: <100K BTU
>100K BTU
Floor Furnace
Suspended/Wall/Floor Mounted Heater
Appliance Vent
Repair or Addition to Heat/Refrig /Cooling System....
Air Handling Unit <10,000 CFM
>10,000 CFM
Evaporator Cooler
Ventilation Fan connected to single duct
Ventilation System
Hood and Duct
Incinerator: Domestic
Commercial/Industrial
EQUIPMENT TYPE AND OUANTITY
0
0
0
0
0
0
0
1
0
0
0
0
0
0
* * continued on next page **
M08 -236
•
Permit Number:
Issue Date:
Permit Expires On:
Phone:
Phone: 253 377 -5247
Phone: 253 752 -4039
Expiration Date: 11/17/2009
M08 -236
10/14/2008
04/12/2009
Fees Collected: $316.25
International Mechanical Code Edition: 2006
Boiler Compressor:
0 -3 HP /100,000 BTU 1
3 -15 HP /500,000 BTU 0
15 -30 HP /1,000,000 BTU.. 0
30 -50 HP /1,750,000 BTU.. 0
50+ HP /1,750,000 BTU 0
Fire Damper 0
Diffuser 0
Thermostat 0
Wood/Gas Stove 0
Water Heater 0
Emergency Generator 0
Other Mechanical Equipment
Printed: 10 -14 -2008
Permit Center Authorized Signature:
doc: IMC -10/06
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
•
Permit Number: M08 -236
Issue Date: 10/14/2008
Permit Expires On: 04/12/2009
I hereby - at I have read and „ ed this permit and know the same to be true and correct. All provisions of law and ordinances
gove g this wor - - •li - hether specified herein or not.
ve authority to violate or cancel the provisions of any other state or local laws regulating
thorized to sign and obtain this mechanical permit.
Signatu Date:
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
M08 -236 Printed: 10 -14 -2008
Parcel No.: 1523049140
Address:
Suite No:
Tenant:
3716 S 144 ST TUKW
WALGREENS REFRIGERATION
1: ** *BUILDING DEPARTMENT CONDITIONS * **
S
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
PERMIT CONDITIONS
•
Permit Number:
Status:
Applied Date:
Issue Date:
M08 -236
ISSUED
09/19/2008
10/14/2008
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: Readily accessible access to roof mounted equipment is required.
6: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
7: Manufacturers installation instructions shall be available on the job site at the time of inspection.
8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila
Permit Center.
9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
11: ** *FIRE DEPARTMENT CONDITIONS * **
12: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the
following concerns:
13: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating
and/or adding sprinkler heads. (IFC 901.4)(Extend sprinlder protection to walk -in cooler.)
14: All new sprinkler systems and all modifications to existing sprinlder systems shall have fire department review and
approval of drawings prior to installation or modification. New sprinlder systems and all modifications to sprinkler
systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk
Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to
the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050)
15: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and
doc: Cond -10/06
M08 -236 Printed: 10 -14 -2008
#2051)
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
6
16: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of
such condition or violation.
17: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at
(206)575 -4407.
doc: Cond -10/06
* *continued on next page **
M08 -236 Printed: 10 -14 -2008
The gr
co
Signa
Print Name.
doc: Cond -10/06
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing
this work will be complied with, whether specified herein or not.
give authority to violate or cancel the provision of any other work or local laws regulating
M08 -236 Printed: 10 -14 -2008
Site Address: 37 L r4-444-- `'ll
Tenant Name:
Property Owners Name:
Mailing Address: 3sti 5 .
Name: l 'X/� I LO e C _
Mailing Address: 20,3.- 1 `J °r.e
E -Mail Address:
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
CITY OF TUKWIL
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http: / /www. ci. tukwila. wa. us
Mechanical Permit N {{�� o. ff^^ -050
Project No.
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
King Co Assessor's Tax No.:
Suite Number:
Ne Tenant:
City
State
'CONTACT PERSON' who do we contact when your permit is ready to be issued
Day Telephone: 3 - 3 �7 4
nivtA &A-- gwo
Cit State Zink
Fax Number:
I City State
Contact Person: 1A -Q,(�` 3 �(� � � Day Telep :2- 154 2 - :2- 154 2 - C r 03
E -Mail Address: , ` Fax Number:. 3 - j 44 0 39
Contractor Registration Number:0% e A LPI N t2146-2...7 Expiration Date: l — 1 ' Z — t '
;ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record
Company Name:
Mailing Address:
City
Day Telephone:
Fax Number:
`ENGINEER OF RECORD — All plans roust be wet stamped by Engineer of Record
Company Name:
Mailing Address:
Zip
Contact Person:
E -Mail Address:
Q:Wpplications\Forms- Applications On Line\3 -2006 = Mechanical Permit Application.doc
Revised: 4 -2006
bh
City
(For< office :use only)
teviozi - 1-02
.... Yes
State
Floor:
Zip
State
Zip
Day Telephone:
Fax Number:
Page 1 of 2
Unit Type:
Qty
Unit Type:
Qty
Unit Type:
Qty
: o filer /Compressor:
Qty
Furnace <100K BTU
Air Handling Unit >10,000
i
Fire Damper
P /100,000 BTU
Furnace>100K BTU
Evaporator Cooler
Diffuser .
3 -15 HP /500,000 BTU
Floor Furnace
Ventilation Fan Connected
to Single Duct
Thermostat
15 -30 HP /1,000,000 BTU
Suspended/Wall/Floor
Mounted Heater
Ventilation System
Wood /Gas Stove
30 -50 HP /1,750,000 BTU
Appliance Vent
Hood and Duct
Water Heater
50+ HP /1,750,000 BTU
Repair or Addition to
Heat/Refrig/Cooling
System
Incinerator - Domestic
Emergency
Generator
Air Handling Unit
<10,000 CFM
Incinerator — Comm /Ind
Other Mechanical
Equipment
i •
Valuation of Project (contractor's bid price): $
Sco e o f Work (please pro ide ailed information):
Zer— *
Use: Residential: New .... ❑ Replacement .... ❑
Commercial: New .... Replacement .... ❑
Fuel Type: Electric ❑ Gas Other:
Indicate type of mechanical work being installed and the quantity below:
Print Name:
I Date Application Accepted:
()Cellos
Q 1Applications\Forms- Applications On Line\3.2006 - Mechanical Permit Application.doc
Revised: 4 -2006
bh
City
4
4A
PERMIT°APPLICATION NOTES Applicalile permits in'this application
° 5 s61,?
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested
in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
E STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
Date:
oot [Avg
Day Telephone:
Mailing Address:
State
Date Application Expires:
Pie 1,f)
Staff Initials:
Zip
ef,„
Page 2 of 2
Receipt No.: R08 - 03305
ACCOUNT ITEM LIST:
Description
MECHANICAL - NONRES
PLAN CHECK - NONRES
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 1523049140 Permit Number: M08 -236
Address: 3716 S 144 ST TUKW Status: PENDING
Suite No: Applied Date: 09/19/2008
Applicant: WALGREENS REFRIGERATION Issue Date:
Initials: JEM Payment Date: 09/19/2008 01:07 PM
User ID: 1165 Balance: $0.00
Payee: ALPINE REFRIGERATION & HEATING, INC.
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 6176 316.25
Account Code Current Pmts
000.322.102.00.0 253.00
000/345.830 63.25
Total: $316.25
Payment Amount: $316.25
55 . C9 19 ')`0 (
TOTAL
doc: Receiot -06 Printed: 09 -19 -2008
Project:
C. ) 16 r e e.z■. f
Type of Inspecti n:
IMP -4,4A
ti �.�
Address:
3 Soj
/
s -
Date Called:
Special Instructions:
///
/
Date Wanted: O , 291.
O
p
Requester:
Phone No:
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
aa.
ARAB 23�
PERMIT NO.
(206)431 -3670
Approved per applicable codes. 0 Corrections required prior to approval.
COMMENTS:
InspectoC:
Date:
it) -Z °E
$60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
Project: !
( 1 (,f e eAJ
Type of Inspection:
f? , A
. `
Address:
3r71� 11 — �
Date Call
Special Instructions:
Date Wanted:
J - (17-4
am.
(1
Requester:
Phone No:
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
PERMIT NO.
(206)431 -3670
Approved per applicable codes. El Corrections required prior to approval.
COMMENTS:
7ia v PSG 4 `oc, cA v
Jq 0 ,j/
Inspect
(Date: /0
❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
I Date:
;(f
COMMENTS:
Type of Inspection: „.... :,-. ,
sef.tlfroA 1:, I _V-. .- / ,1 i
Address: 37/ 5
Suite #:
P
Contact Person:
Special Instructions:
6) 54 : el 14 je vi., ii,14 I -I(/' ,), C i , c<,
\--
Phone No.:
) fe., • rt' : eL3t. I
i
Pre-Fire:
Permits:
1.- .
r el z ) i?): A /I c.? 4
/
---) , A .4), o-:, ._.),...ii,
&....3.61cc-.1.,'
-th,_...... ..,--, ,--,-....-3 _ Pc-, t- ;
Project: 1- I i 5r e 9
Type of Inspection: „.... :,-. ,
sef.tlfroA 1:, I _V-. .- / ,1 i
Address: 37/ 5
Suite #:
P
Contact Person:
Special Instructions:
Hood & Duct:
Phone No.:
Needs Shift Inspection:
Sprinklers:
Fire Alarm: -
Hood & Duct:
/
Monitor:
i
Pre-Fire:
Permits:
/
Occupancy Type:
/
INSPECTION NUMBER
444 Andover Park East, Tukwila, Wa. 98188 206-575-4407
n Approved per applicable codes.
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA FIRE DEPARTMENT
Do7 - 077
m
-21t
PERMIT NUMBERS
Corrections required prior to approval.
Inspector: j
Hrs.:
Date: r
$80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Word/Inspection Record Form.Doc 1/13/06
T.F.D. Form F.P. 113
Room
Temp
Cond. Unit
Model
Compressor
Model
Unit
STUH*
Electrical"
Refrig.
Type
Connections
Receiver
Pump Down
Cap. 90 /o
Ship
Wt.
Base
Sizet
Voltage
MCA
MOP
RLA
LRA
Suction
Liquid
40
BSHX020VCC
ZS15K4E -TF5
17,600
200 - 230/60/3
14
20
9.3
55
R-22
7/8
5/8
29.4
400
C
40
BSHX030VCC
ZS21 K4E -TF5
24,300
200. 230/60/3
19
25
11.1
77
R-22
7/8
5/8
47.6
405
C
40
BSHX025VCC
ZS19K4E -TF5
21,400
200 - 230/60/3
16
20
9.7
63
R-22
7/8
5/8
29.4
405
C
40
BSHX050VCC
ZS38K4E -TF5
40,800
200. 230/60+3
30
45
21.4
123
R-22
7/8
5/8
47.6
420
C
40
BSHX050LCC
ZS38K4E -TF5
41,900
200. 230/60/3
32
50
21.4
123
R-22
7/8
5/8
47.6
560
D
40
BSHX060VCC
ZS45K4E -TF5
51,600
200-230/60/3
45
CO
23.9
156
R -22
7/8
5/8
47.6
520
D.,
40
BSHX075VCC
Z856K4E -TWC
62,100
208. 230/60/3
45
70
30.9
189
R -22
11/8
7/8
47.6
600
0
40
BSHX100VCC
ZS75K4E -TWC
84,900
200. 230/60/3
61
100
44.9
278
R-22
11/8
7/8
116.1
950
F
30
BSMX020VCN
ZS15K4E -TF5
15,600
200. 230/60/3
20
25
9.3
55
R-22
7/8
5/8
29.4
400
C
3)
BSMX040VCN
ZS30K4E -TF5
28,900
200. 230/603
36
40
15.0
99
R -22
7/8
1/2
41.5
510
C
30
BSMX025VCC
ZS19K4E -TF5
17,800
200-230/60/3
15
20
9.7
63
R-22
7/8
5/8
29.4
405
C
30
BSMX030VCC
ZS21 K4E -TF5
20,100
200. 230(60/3
19
25
11.1
77
R-22
7/8
5/8
47.6
400
C
30
BSMX050VCC
ZS38K4E -TF5
34,800
200 - 230/60/3
46
90
21.4
123
R -22
7/8
5/8
47.6
420
C
30
BSMX050LCC
ZS38K4E -TF5
35,900
200. 230/60/3
45
50
21.4
123
R -22
7/8
5/8
47.6
550
D
36
BSMX050VCN
ZS38K4E -TF5
34,800
200. 234
45
50
21.4
123
R -22
7/8
5/8
47.6
520
C
30
BSMX050VCK
ZS38K4E -TF5
35,900
200. 230/60
45
50
21.4
123
R-22
7/8
5/8
47.6
550
D
30
BSMX060VCC
ZS45K4E -TF5
42,500
200. 230
45
60
23.9
156
R-22
7/8
5/8
47.6
600
D
30
BSMX060VCN
ZS45K4E -TF5
42,500
200.230/60/3
45
CO
23.9
15•
R-22
7/8
5/8
47.6
600
D
30
BSMX075VCC
ZS56K4E -TWC
51,400
208- 230/60/3
45
70
30.9
189
R-22
1 1/8
7/8
47.6
600
D
30
BSMX100VCC
ZS75K4E -TWC
74,100
200. 230/60 /3
76
100
44.9
278
R-22
11/8
7/8
47.6
950
F
-10
BSI1030VCC
ZFO9K4E -TF5
10,700
200 - 230/60/3
23
30
11.1
77
- R-404A
7/8
1/2
25.6
405
C
-10
BSL2040VCC
ZF13K4E -TF5
15,000
200. 230/60/3
32.
40
15.0
99
R-404A
7/8
1/2
41.5
410
C
WG-4A, R51 R2201 CC
ZS38K4E -TF5
38,000
200 - 230/60/3
96
110
21.4
123
R-22
7/8
1/2
342
1630
W
25
ZS38K4E -TF5
32,000
200. 230
21.4
123
R-22
7/8
1/2
342
W
-10
ZF13K4E -TF5
17,000
200- 230/60/3
15.0
99
R-404A
7/8
1/2
29.7
W
-10
ZF13K4E -TF5
17,000
200. 230/60/3
15.0
99
R-404A
7/8
1/2
29.7
W
WG -4AD, R51 82201 CD
35
ZS38K4E -TF5
38,000
200- 230/60/3
96
110
21.4
123
R -22
7/8
1/2
342
1630
W
25
ZS38K4E -TF5
32,000
200. 230/60/3
21.4
123
R-22
7/8
1/2
342
W
-10
ZF13K4E -TF5
17,000
200 - 230"60/3
15.0
99
R-404A
7/8
1/2
29.7
W
-10
ZF13K4E -TF5
17,000
200. 230/60/3
15.0
99
R-404A
7/8
1/2
29.7
W
WG-4AH, R51R2201CK
35
ZS38K4E -TF5
38,000
200 - 230/60/3
100
110
21.4
123
R-22
7/8
1/2
342
1630
W
25
ZS38K4E -TF5
32,000
200. 230/60/3
21.4
123
R-22
7/8
1/2
34.2
W
-10
ZF13K4E -TF5
17,000
200. 230/60/3
15.0
99
R-404A
7/8
1/2
29.7
W
-10
ZF13K4E -TF5
17,000
200. 230/60/3
15.0
99
R-404A
7/8
1/2
29.7
W
UNIT BASE SPECIFICATIONS
)< BASE "C"
BASE "D"
BASE "E"
BASE "W"
.. (1) Locking Latch This Side For Pad)
(Padlock By Others)
35 -1/4"
r 34'
Piping
Connections
I 29 -7/16' Sadal I r' Plates
518' Diameter Mounting Holes
Electrical Connections (Inside Weather Hood)
(1) Locking latch This Side For Padlock
(Padlock By Others
41 -3/8'
r 40 -1/8'
Air Row
35-1/4'
Piping Connections
Nomenclature And Serial
35 Number Plates
5/8' Dia. Mounting Holes
Electrical Connections (Inside Weather Hood)
( 1) Locking Latch This Side For Padlock
L Provided By Others)
Electrical Connections
(Inside Weather Hood)
51'
49- 11/16'
�- 32- 15/16')
5/8' Die. Mounting Holes
Nomenclature & Serial N
Plates Located On Outside
Electrical Box Cover
PLUMBIN CONNECTIONS
LEFT EN
38 -3/4'
2' 5/8' DIA. MOUNTING H
- 44 -3/4' WIDTH
42 -1/2"
Piping
Connections
46-1/2'
45-9/16"
28 -1/4'
Air Flow
1a1/
7 -1
REVIEWED FOR
CODE COMPLIAN
APPROVED
OCT 0 7 2008
34 -1/4" 30" ( 34 -1/4°
•
q 5/8' DIA. MOUNTING HOLES
108' LENGTH
SECTION 5 CONDENSING UNITS AND REFRIGERATION SYSTEMS
Air Flow
(4)1.117 Dia. lifting
42 -1 /2'
Q5/8' Die. Mounting Holes
- 45-1 /2'
(4)1.1/2' Dia. rating Hales
42 -1 /2'
518' Dia. Mounting Holes
41 - 7/8'
L ( 1/rola.taegr
3e -3/
@518 Dia. Mounting Holes
42-3/4'
ELECTRICAL,
RIGHT END
Air Flow
f-
Air Flow
Condensing Unit Specifications
• BTUN based on 90 Deduct 7% for each 10 degree rise over 90°F.
"MCA does not include evaporator amps for room temperature 35°Fand above.
t See page 21 for base sizes.
RECEIVED
CITY OF TUKWLA
OCT 0 6 2008
PERMIT CENTER
CONTINUED ON NEXT PAGE
INCOMPLETE
LTR#
AA OS $
21 SECTION 5 CONDENSING UNITS AND REFRIGERATION SYSTEMS 19
COOLER DIMENSIONS
W
I L
Ba.2
V.S
Cs
DEW
JS
CS
BE46
us
10d
MOOS
Ss
BBC'
MDOR
7s
B-?
CONDENSING UNIT WEIGHTS
3 HORSEPOWER
505
LBS
5 HORSEPOWER
520
LBS
MOWER
wW OLER W /PRODUCT DOORS)
1225
LBS
OPEN FRONT COOLER)
S
DOOR DETAILS
O STEEL RAIN GUARD, DORBIN lOtA, AT EXTERIOR FRAMES.
O2 SEE CONSTRUCTION DRAWING FOR LINTEL DESCRIPTION.
O ELASTIC SEALANT. CAULK AT HEAD AND JAMBS. COLOR TO MATCH
FRAME (TYPICAL).
0 FILL HEAD AND JAMB WITH MORTAR.
O CONTINUOUS SHIM BEHIND DRYWALL
O SALES AREA SIDE OF FRAME TO BE TIGHT AGAINST WALL.
O WALL MATERIAL. SEE FLOOR PLAN /ELEVATION.
O SET ANCHORS PER MANUFACTURER'S SPECIFICATIONS.
O CERAMIC TILE BULLNOSE TRIM B" X 5/16" THICK.
1D WHERE JAMB MEETS FLOOR, CAULK ALL SIDES.
11 AIR CURTAIN UNIT; HEAT ELEMENT WHERE APPUCABLE.
O TYPICAL JAMB AT MASONRY
1 I/2' -
1/2'
AA
1 15/1fi y�y�yl 1/16"
11 'n ' "IIII
O TYPICAL METAL FRAME
I 1/2" -
SILL
KEYED NOTES
LEVEL
LEVEL �
NOTE ADJUST
t1E912 DISCHARGE NOZZLE
2S TOWARDS
EXTERIOR
SLOPED RECESSED
THRESHOLD TO
RECEIVE ROLL-UP
DOOR
2 ROLLING STEEL DOOR DETAILS
SCALE 1 1/2' -1' -O"
I2 TO UN AIR CURTAIN UNIT VERTICAL SUPPORT RODS; EACH END. FASTENED
O 1/8" BENT STEEL PLATE, FULL HEIGHT, W/ 1/8' X 2' X B' JAMB
STRAPS AT 32" O.C. VERTICALLY. SEAL ALL AROUND.
14 JAMB GUIDES. SILL AND WEATHERSTRIP BY DOOR CONTRACTOR.
15 ALUMINUM THRESHOLD. SEE HARDWARE SCHEDULE, DOOR "J ".
HOOD FOR COILING DOOR A CHAIN DRNE.
VERTICAL WOOD REINFORCING AT JAMBS.
BRUSH TYPE WEATHERSTRIP.
DOOR BOTTOM BRACKET IN OPEN -DOOR POSITION TO CLEAR AIR
CURTAIN UNIT. PROVIDE STOP AT JAMB
UNISTRUT SUPPORT FASTENED TO AIR CURTAIN UNIT.
WALL BRACKETS TO LATERALLY SUPPORT AIR CURTAIN. ALLOW FOR
CLEARANCE OF MANUAL PULL CHAIN.
AIR CURTAIN ELECTRICAL
MANUAL PULL CHAIN GUIDE.
16
19
4" FRAME PERMITTED
O TYPICAL HEAD AT MASONRY
1 1/2" = 1' -0"
cD
*OW O
6 1/4
JAMB AT 7" (NOM,}'
O STUD WALL (HEAD" SIMILAR)
1 1/2" - 1' -0'
,TIILET RDOM DOOR
JAMB AT 5" (NOM.) . .
OSTUD
WALL (HEAD SIMILAR) OTYPICAL SILL DETAILS
1 I I /2 " = 1 . -0 " 1 1 'I, 1/2" - 1' -0 '•,
TYPICAL METAL FRAME DIMENSIONS
NOTE: ALL METAL FRAMES ARE WELDED
A - 4 3/4" AT 4" (NOM.) MASONRY WALL
A = 5 3/4" AT 6' (NOM.) OR THICKER MASONRY WALL
A 5 3/4" AT 5" STUD WALL
A - 8 1/4' AT 7' STUD WALL (SPECIAL ORDER - ALLOW 6
WEEK DELIVERY)
NOTE: BOTTOM
OF OVERHEAD
DOOR HOOD TO
BE 1' -0' ABOVE
OVERHEAD DOOR
WALL OPENING
HEIGHT.
mE
El FVATION
3' -6 3/4'
CURBS RH CROSS AISL
GOOLE ONLY
.....„„..........„7.. LINE OF COOLER /FREEZER BELOW
3' -6 3/4'
WC -3 AND WO -A UNIT
• 00
3�V
G
o rnK
'PLAN
SCALE 1 " -1' -0"
NQIEs COORDIRATE JOLT SPACING TO
CLEAR LADDER AND ROOF.SCUTTLE.
O.S.HA LADDER CLEARANCES'MUST BE
MET -NO OBSTRUCTIONS IN AREAS, BELOW
ROOF HATCH. •
•
PROVIDE SAFTY CAGE IF LADDER EXCEEDS
20' -0" IN HEIGHT.
PLAN,.'- ROOF CURBS
LAbOER & SEUTTLE'-. QETAIL
O SECTION
SCALE 1 I/2 " -1' -O'
� SECTION
1 1/2' 1' -0"
KEYEP NOTES
• VERIFY INCREASED
CLEARANCE W/
LOCAL BUILDING
CODES.
ROOF DECK.
._PREFAB METAL CURB WITH WOOD
(2 -X 6) NAILER. TOP OF RAIL TO BE
/� LEVEL:.
�'/ 2 -PLY FECT'.FLASHING.
CONDENSING UNIT. SEE ENGINEERING
D.
O PIPE CHASE (REFRIGERANT LINE
PORTAL SHALL OTED OVER
CENTER OF COOL ER L /FREEZER CA ON
COOLER /FREEZER SIDE OF SALES
WALL). SEE 5/M2.1 MID /OR 3/A1.4).
KEYED NOTES
0 ROOF SCUTTLE - 2' -6" X 3' -0" TYPE "5" WITH
(ADDER -UP" SAFETY POST MODEL 2 BY BILCO
CO. SECURE SCUTTLE 10 ROOF STRUCTURAL
STEEL WITH THRU BOLTS ACCORDING TO
MANUFACTURER'S DIRECTIONS. HINGE PINS ARE
TO BE WELDED NON- R2MOVEABLE.
O STANDARD 1" FIBER CANT. BUILT UP ROOFING,
AND COUNTER FLASHING (AS REQUIRED).
0 3 -1/2" K 3 -1/2" K 1/4' ANGLED WELDED
FRAME. EXTEND AND SECURE TO BUILDING
ROOF STRUCTURE AS REQUIRED.
0 2 -1/2' X 3/B' FLAT STEEL. BAR SIDE RAILS.
AND 1" a STEEL RUNGS PUNCHED INTO RAILS
12' CENTERS AND WELDED. RUNGS ARE TO BE
KNURLED OR DIMPLED TREATED TO MINIMIZE
SLIPPING AND ARE TO OE FREE OF SHARP
EDGES.
0 PROVIDE 2 -1/2" X 3 /P." THICK FIAT BENT
STEEL BRACKETS AT MAX. 4' -0" CENTERS.
ANGLE
WELD TO FRAM SIDE E. RAILS WELD TOP TO STEEL
O AT METAL STUD WALL, PROVIDE 1 -1/2' C.R.
STEEL REINFORCING CHANNELS WITH WELDED
,3'8 THRU BOLTS TO RECEIVE BRACKETS.
:CUT STUD FLANGES TO RECEIVE RENFORCING
CHANNNEL. AT MASONRY. FASTEN BRACKETS
"WITH MQLLY, 3�6" gN 5 CHOR 2 -3/ TS. HEAD" "RED HD" OR
O PROVIDE'.2-1/2" X 2 -I /2" X 3/16' WELDED
CLIP ANGLES SECURED TO CONCRETE FLOOR
WITH '0 X 2 -3/4" WEDGE 'RED HEAD' OR
'-'MOLLY ANCHOR BOLTS.
FRP WALL PANELS, FLOOR TO ROOF.
.OASLEETED FAT €NER.
17, "5 ROUS(1 PINE. ..NAILER TREATED WITH
CUPRINOL'••
I1 WOOD NAILER "FASTENSC TO ROOF DECK:
THICKNESS TO MATCH 19P OF ROOF DECK
INSULATION.
NON -SUP METAL LANDING SUSPENDED FROM ROOF.
GUARD RAIL
NOT USED
Z ¢ 1a , Q r� ! r , e. e,, ri .
FACILITIES PLANNING. DESIGN, & ENGINEERING
106 WILMOT ROAD
DEERFIELD, IL 60015 -5105
NOTE
DE DRAWING IS PROPERTY OP THE WNGfEEI COMPANY. R
IS MEANT FOR REFER ONLY. ANY OTHER 115E OR
REPRODUCTION N PART OR IN TOTAL IS PROMOTED WITHOUT
AUTHOR/ETON FROM THE WHEN COMPANY.
PROJECT TYPE
TURNKEY PROJECT:
WALGAEE D DRAWINGS AND BPEDffICATION5 ARE INTENDED
TO SNOW ONLY WALGREENS' OHJTERIA RQUIRE6@ITS, ALL
ARCHITECTURAL STRUCTURAL, MECHANICAL. AND ELECTRICAL
ENGINEERING SHALL FOLLOW THS CRITERIA., AND BE PROVIDED
BY LANDLORDS ARCHITECT HTECT AND ENGINEER. R. ALL
CCNSTRUCTDNI WORK BY LNDLCRDB' CONTRACTOR UNLESS
NOTED OT ERWOSE
RECEIVED
CITY OF TUKWILA
OCT 0 6 2008
PERMIT CENTER
ND.
FEB. 2007
DATE
CADD PLOT:
VOID PLOT:
SUPERSEDES
PLAN DATED:
REV. FROM FISCAL 2006 CRITERIA
DESCR IPTICN
COAST
REVISIONS
CERTIFICATION AND SEAL
I HEREBY CERTIFY THAT THIS
PLAN AND SPECIRCJRDN
WAS PREPARED BY ME OR
UNDER MY DIRECT
SUPERVISION AND THAT I AM
A DULY REGISTERED
ARCHITECT OR ENGINEER
UNDER THE LAWS OF THE
STATE OF )0000000( AS
BKWIFED BY MY HAND AND
SEAL
THESE COPYRIGHTED
DRAWINGS ARE TO BE USED AS
iEEERFNI[f ONLY. "IS THE
RESPONSIBILITY OF THE
UCENSED PROFESSIONAL TO
GENERATE PLANS,
DENIMS, SECTIONS, AND
ADDITIONAL DETAYS BASED
ON THE JOB SPECIFIC MOUE
PLAN (D1). MISUSE OF THESE
DRAWINGS IN ANY WAY MAY
RESULT IN LEGAL ACRONL
CRITERIA FEBRUARY 2007
NAME
WALG N STORE
CRITERIA DRAWINGS
114'-0' X 130'-0'
DRAWING TITLE
ROOF CURB/DOOR DETAILS
SCALE: AS NOTED
DRAWN BY:
JAM.
DATE FLDNi_
REVIEWED BY:
ROYCE
DRAWING NO.
A4.5
OF DWGS.
045 -00207
COPWOOMPOZIO NBONa
1
N
1
4"
s c
OCI
DIRECTIONAL SYMBOL
SHOWN FOR DRAWING
ORIENTATION ONLY
CV
00
10 5/16"
10 5/16"
u_
CD
CD
CD
N. S. F.
LISTED
CONSTRUCTION
1/2"
3' 7 13/16"
1"f
3'-6" "
W57GL
6F
W92
OC_. 0_L ER_
GL
E1HX0090VA
W46F I W46F Cl 1
W92GL
20' -4 15/16"
2G
24 GA. WG BEIGE GALVANIZED STEEL
WALL PANEL PLAN
NOTE: CONDENSATE DRAIN LINES BY OTHERS. WALGREENS SPECIFIES
COPPER ONLY WITH CLEAN OUT ACCESS IN BOTH COOLER AND FREEZER.
WALGREENS SPECIFIES THAT DRAIN LINE HEATER BE PROVIDED BY REFRIGERATION
CONTRACTOR. IT SHOULD BE 6W — 7W PER FOOT AND EITHER 110 V. OR 208/230 V.
WRAPPED SPIRAL AROUND PIPE ON 1" CENTERS AND PROPERLY INSULATED.
X
C7
N
U
W57GL
W92GL
OPENING ONLY FOR (9)
26 "x73" ANTHONY
MODEL 101 GLASS DOORS
20' -4 15/16"
W92GL
T
C0
W57GT 1 W92GT 1 W92GT
0
CV
U
8 1/8"
SOUTH WALL ELEVATION
FINISHED DRYWALL OPENING FOR GLASS
DOORS TO BE MINIMUM 20' -11" x 7' -0 ".
ALLOW 1" MINIMUM CLEARANCE ALL AROUND WALK —IN.
PROPRIETARY INFORMATION
THIS DRAWING IS THE PROPERTY OF MASTER —BILT
PRODUCTS. IT CONTAINS PROPRIETARY INFORMATION
AND IS DISCLOSED IN CONJUNCTION WITH THE UNDER—
STANDING THAT IT WILL NOT BE REPRODUCED OR
COPIED, DIRECTLY OR INDIRECTLY, AND IS NOT TO BE
USED IN WHOLE OR IN PART TO ASSIST IN MAKING OR
TO FURNISH ANY INFORMATION FOR THE MAKING OF
DRAWINGS OR PRINTS OF APPARATUS EMBODYING
FEATURES, DATA OR INFORMATION DERIVED IN ANY
MANNER FROM THIS DRAWING WITHOUT THE EXPRESS
WRITTEN CONSENT OF MASTER —BILT PRODUCTS.
NOTE: THESE MATERIALS ARE ALSO PROTECTED
UNDER COPYRIGHT LAW AND TREATIES.
L
10 1 /4"
10 1 /4"
FLAME SPREAD 25
SMOKE DENSITY 440
GALVALUME DOOR TRIM
(700 -17111 & 700- 17112)
f
bo
1T
c0
CID
FACTORY MUTUAL RESEARCH TESTED
ASTM E84 -94 TEST METHOD
CORE INSULATION TESTED 4" THICK
REPORT J.I.3136A5.AM REPORT J.I.OB2A6.AM
FLAME SPREAD 25
SMOKE DENSITY 175
These Numerical Values Are Not Intended To Reflect
Hazards Presented Under Actual Fire Conditions
Approval Requires Mechanical Through— Fastening
From Interior To Exterior Panel Skin.
6' -9" i'2' -11 ".e-
EAST WALL ELEVATION
REFRIGERATION
UNITS
BSHX025VCC
2:ElHX0090VA
BSLZ040VCC
22' -1 1/2"
ROOF PANEL PLAN
INT.
FIN.
r
P e r ^r j!
SPECIFICATIONS
F. NONE
4" URETHANE FOAM
DOOR OPNG:36" x 78"
i
� F "�' E P
Ir �a `7 COP
NOTE: ALLOW 1 INCH MINIMUM CONSTRUCTION CLEARANCE ALL AROUND WALK —IN.
ALLOW 2 INCH MINIMUM CONSTRUCTION CLEARANCE ABOVE WALK —IN.
SIZE W:9' -8" L:22' -1.5" H:8'—
R: 26 GA. STUCCO GALVALUME
W:26 GA. STUCCO GALVALUME
F: NONE
EXT R: 26 GA. STUCCO GALVALUME
FIN. W: 26 GA. STUCCO GALVALUME
ROOF LOAD = ** PSF (MAX. LL + DL)
ACCESSORIES:
(1) 1094 DOOR CLOSER
(1) 3" DIAMETER DIAL THERMOMETER
(15) TUBES GRAY BUTYL CAULKING
(6) TUBES GRAY SILICONE CAULKING
(12) 3/8" X 8" NYLON BOLTS W /NUTS & WASHERS
(1) MODULARM 75 —B TEMP ALARM
ELECTRICAL DATA:
V39RV098 — 115/60/1 PH 1.97 AMPS (cooler)
BSHX025VCC 200- 230/60/3
MCA: 16
MOP: 20
RLA: 9.7
LRA: 63
COOLER EVAP. COILS:
(2) E1HX009OVA — 115/60/1 PH 2.0 FAN AMPS EA.
DEERFIELD, IL
TUKWILA, WA
DWG BY: PR
REVIEWED FOR
CODE COMPLIANCE
APPROVED
CKD BY: f
OCT 0 7 2008
VAI
Of Tuk iila
BUILDING DIVISION
RECEIVED
CITY OF T1JL`
SEP 19 '1008
PERMIT CENTER
WHEN FACING THE INTERIOR OF THE WALL
PANEL, ALL VERTICAL LATCH ACCESS HOLES
SHOULD BE ON THE LEFT SIDE OF THE PANEL
MI MASTEI-111 T ®
Refrigeration Solutions
WALGREEN CO. V #059204
REF: STORE #10995
DATE: 9/11/08
DWG NO:
58352
PG N0:
1 of 1
SCALE: 3/16 " =1'
September 23, 2008
Paul Brewer
2002 North Fremont
Tacoma, WA 98406
Dear Mr. Brewer,
Sincerely,
writ (kci
Brenda Holt
Permit Coordinator
Enclosures
File: M08 -236
•
CI of f 7iY
Department of Community Development
RE: Letter of Incomplete Application # 1
Development Permit Application M08 -236
Walgreens — 3716 South 144 Street
This letter is to inform you that your permit application received at the City of Tukwila Permit Center on September 19,
2008 is determined to be incomplete. Before your application can continue the plan review process the following items
from the following department needs to be addressed:
Building Department: Allen Johannessen at 206 433 -7163 if you have any questions concerning the
attached comments.
Please address the comment above in an itemized format with applicable revised plans, specifications, and/or other
documentation. The City requires that two (2) sets of revised plans, specifications and/or other documentation be
resubmitted with the appropriate revision block.
In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have
enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by
a messenger service.
If you have any questions, please contact me at the Permit Center at (206) 431 -3670.
PAPermit Center\Incomplete Letters\2008\M08 -236 Incomplete Ltr 111.DOC
jem
•
Jim Haggerton, Mayor
Jack Pace, Director
6300 Southcenter Boulevard, Suite #100 ° Tukwila, Washington 98188 o Phone: 206- 431 -3670 0 Fax: 206 - 431 -3665
•
Determination of Completeness Memo
Date: September 23, 2008
Project Name: Walgreens Refrigeration
Permit #: M08 -236
Plan Review: Allen Johannessen, Plans Examiner
Tukwila Building Division
Allen Johannessen, Plan Examiner
The Building Division has deemed the subject permit application incomplete. To assist the applicant in
expediting the Department plan review process, please forward the following comments.
(GENERAL NOTE)
PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size).
(If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped,
not copied.)
1. Please provide manufacture specifications for the refrigeration units to be place on the roof. Specks shall
include the weight of the units.
2. Provide details for the roof curbs and identify how the units shall be secured to the curb. Show how the
roofing is sealed around the curbs.
Should there be questions concerning the above requirements, contact the Building Division at 206 - 431 -3670.
No further comments at this time.
ACTIVITY NUMBER: M08 '(p DATE: 10 -06 -08
PROJECT NAME: WALGREENS
SITE ADDRESS: 3716 S 144 ST
Original Plan Submittal
Response to Correction Letter #
X Response to Incomplete Letter # 1
Revision # after Permit Issued
DEPARTMENTS: I /I
B i t;J ng :'vision
Public Works
Complete
Comments:
APPROVALS OR CORRECTIONS:
Documents/routing slip.doc
2 -28 -02
PERMIT COORD COPY el
PLAN REVIEW /ROUTING SLIP
Fire Prevention
Structural
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Incomplete
TUES/THURS ROU NG:
Please Route Structural Review Required
REVIEWER'S INITIALS:
Approved ❑ Approved with Conditions
Notation:
REVIEWER'S INITIALS:
n
Planning Division
n Permit Coordinator ❑
DUE DATE: 10-07-08
Not Applicable n
Permit Center Use Only
INCOMPLETE LETTER MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
LETTER OF COMPLETENESS MAILED:
No further Review Required
DATE:
DUE DATE: 11-04-08
Not Approved (attach comments) n
DATE:
C
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
ACTIVITY NUMBER: M08 - 236 DATE: 09 - -
PROJECT NAME: WALGREENS REFRIGERATION
SITE ADDRESS: 3716 S 144 ST
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # after Permit Issued
DEPARTMENTS:
I�
B !vision
Public Works
� PERMIT COORD COPY «
PLAN REVIEW /ROUTING SLIP
hvv(i 14A
Fire Prevention
Structural
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
Incomplete
TUES/THURS ROUTING:
Please Route Structural Review Required
REVIEWER'S INITIALS:
APPROVALS OR CORRECTIONS:
Documents/routing slip.doc
2 -28 -02
Ti
n Permit Coordinator
DUE DATE: 09-23 -08
Not Applicable n
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: s)..)
Departments determined incomplete: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials:
No further Review Required
DATE:
DUE DATE: 10-21-08
Approved Approved with Conditions n Not Approved (attach comments) n
Notation:
REVIEWER'S INITIALS:
DATE:
Planning Division
n
U
n
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through
the mail, fax, etc.
Date: 1D/610g Plan Check/Permit Number: M08-236
• Response to Incomplete Letter # 1
❑ Response to Correction Letter #
❑ Revision # after Permit is Issued
❑ Revision requested by a City Building Inspector or Plans Examiner
Project Name: WALGREENS
Project Address: 3716 South 144 Street
Contact Person: Paul Brewer Phone Number: ;253 - c37 7 -6?-47
Summary of Revision:
Sheet Number(s): AO
"Cloud" or highlight all areas of revision including date of revision
ci OF SILA
OCT 0 6 2008
PERMIT CENTER
Received at the City of Tukwila Permit Center by:
„kr Entered in Permits Plus on
\applications \forms- applications on line\revision submittal
Created: 8 -13 -2004
Revised:
Name
Role
Effective Date
Expiration Date
JONES, SIEGHILD I
Cancel
Date
01/01/1980
Bond
Amount
COLUCCI, RANDY
4
01/01/1980
SRS1022351
JONES, TANJA
Until
Cancelled
01/01/1980
Bond
Bond
Company
Name
Bond
Account
Number
Effective
Date
Expiration
Date
Cancel
Date
Impaired
Date
Bond
Amount
Received
Date
4
RLI INS
CO
SRS1022351
06/26/2004
Until
Cancelled
$6,000.00
06/17/2004
3
GULF INS
CO
S U43424
11/05/2001
Until
Cancelled
06/26/2004
$6,000.0011
/07/2001
2
INS
CO
SU43424
SU43424
06/26/2001
11/05/2001
$4,000.00
07/05/2001
1
AMERICAN
RELIABLE
SU43424
06/26/1998
06/26 /2001
$4,000.00
Untitled Page
•
•
General /Specialty Contractor
A business registered as a construction contractor with LEtI to perform construction work
within the scope of its specialty. A General or Specialty construction Contractor must
maintain a surety bond or assignment of account and carry general liability insurance.
Business and Licensing Information
Name ALPINE REF Ft
HEATING INC UBI No. 601789061
Phone 2537524039 Status ACTIVE
Address PO BOX 7464 License No. ALPINRH027L6
Suite /Apt. License Type CONSTRUCTION CONTRACTOR
City TACOMA Effective Date 6/26/1998
State WA Expiration Date 11/17/2009
Zip 98407 Suspend Date
County PIERCE Previous
License
Business
Type
Parent
Company
CORPORATION Next License
Associated
License
Specialty 1 COMMERCIAL /INDUSTRIAL /REFRIG
Specialty 2 UNUSED
Business Owner Information
Bond Information
https: / /fortress.wa. gov /lni/bbip/Detail. aspx ?License= ALPINRH027L6
Page 1 of 2
10/14/2008
■
MSC429696
73'-11
10'-2
MS2475120---BP2S
MSC427296
GENERAL STOCK
MS3096120
MS429696-5S
26939
CO226939 CO226934
8
PLANK O
FLOORING
El 936
#
FE &
PANEL
SECURITY C :INET
MS3096120
El 936
E1936
E1936
E1936
E1936
• 1
El 936
E1936
ir H II
I 111 II
II H 1111
111 10 • - 5"
7 -0" 11 17 8 1 -5"
5 -0" MI • 11111
RI
II H II
II H II
IIP 10 I
IN IN IN
El 936
TRAINING
22X36
CABS
.rt maw= NE in El
Z1/4 MOM Ili MO IN
Ell •11111111111•1•11
OFFIC
E1936
8
El 936
8
El 936
.
6 )AJ
feez
T'
-41VIINMIII•IiiNSaiea
CZ
P
SECURITY LEVEL 4
PLEASE INCLUDE THE FOLLOWING SECURITY MEASURES:
1. INTERNAL-16CAMERA CCTV WITH PTZ AND DVR.
2. 2 INCREMENTAL PVMS ($1500)
HRP LOCKING PACKAGE($2000)
LLw
cn co
z 0
z 0
< 0
ce <
0 LL :E
0
R Li
z z
o cL
PF
W O 0
-J 0
01- z
04 0 <
< <
x ( f )
Lil
*A.D.A DOOR CLEARANCES
*ACCESSIBLE REQUIREMENTS1VIA VARY
WITH LOCAL JURISDICTIONS '
APPROACH TO DOOR SVV1N
- .Nussommurisseirsomm ax
TOTAL BY LINEAL FOOTAGE
FRONT WALL SHELVING (INCLUDE 54" HIGH WALL AT PHOTO)
COSMETIC WALL SHELVING
REMAINING WALL SHELVING (BACK & SIDE WALL, RX SEATING)
BACK GONDOLAS
FRONT GONDOLAS
HALLMARK SHELVING
COSMETIC GONDOLAS
COOLERS
FREEZERS
INCLUDE CART SECURITY
S
SENIOR VICE PRESIDENT
FACILITIES DEVELOPMENT
SENIOR VICE PRESIDENT
STORE OPERATIONS
VICE PRESIDENT
STORE OPERATIONS
REVIEWED BY:
FOR REFERENCE ONLY: SEE CONTRACT
DOCUMENTS FOR DETAILED SITE PLAN
EXECUTIVE APPROVAL
HANDAL
HASTY
to
oti.fsmintd■
875 LN. FT.
51 LN. FT.
66 LN. FT.
60 LN. FT.
336 LN. FT.
213 LN. FT.
95 LN. FT.
24 LN. FT.
20 LN. FT.
10 LN. FT.
DATE
1-22-07
1-22-07
C.E
9.19.06 9.18.06
1
oluN "u" DOWNTOWN CHECKOUT LANE #
SIGN "CA" CALIFORNIA ACCESSIBILITY SIGN (9'-6" TO
BOTTOM OF SIGN)
PHARMACY DEPARTMENT:
REFER TO FIXTURE PLAN FOR REQUIRED SIGNS
SIGN "J" PICK UP PRESCRIPTIONS
SIGN "K" DROP OFF PRESCRIPTIONS
SIGN "Q" CONSULTATION WINDOW
SIGN "TX" T. A. S.
SIGN "ADA" SYMBOL OFACCESSIBILITY
ATTACH SIGNS TO UNDERSIDE OF CASED OPENINGS.
REFER TO FIXTURE PLAN FOR SIGN LOCATION.
PROVIDE (2) HOLLOW WALL ANCHORS PER SIGN.
SCREW THREADED EYEBOLT INTO ANCHOR. HANG
SIGNS FROM EYEBOLTS WITH "S" HOOKS.
GENERAL SALES AREA:
1. PLEASE PROVIDE PROPER A.D.A. CLEARANCES
ON BOTH SIDES OF ALL DOORS
2. MIRROR ON REAR WALL
3. COSMETIC CORNICE
4. SALES AREA CORNICE (FIXTURE MOUNTED)
5. PHOTO CORNICE (FIXTURE MU) UNLESS NOTED)
6. CARPET TILES & DESIGN LINKS FURNISHED AND
INSTALLED BY WALGREENS (WHEN SHOWN)
7. MASTER-BILT REACH-IN REFRIGERATION:
(PROVIDE 2" AIR SPACE BETWEEN COOLERS
AND FREEZERS)
OPEN FRONT, MEDIUM TEMP. COOLERS
(ADD 2" AT EACH END, FOR END pAkELS)
A. MD-06: 6'-0'W X 42 7/8"D
B. MD-08: 8'40W X !42716"D
MODEL TEL-ENDLESS REACH-IN FREEZERS
(ADD 2" AT EACH END, FOR END PANELS)
C. TEL-4-24: 100 1/4"W X 37 3/4"D X 80"H
D. TAF-48HD: 52"W X 35 3/4"D X 81.5"H
E. SMB-580 WINE COOLER: 70"W X 32"D X 76.5"H
8. MASTER-BILT WALK-IN COOLER: PROVIDE
9 #1000R COOLMASTER DOORS
26 3/4" X 73" EACH AND
4 #100FR FREEZEMASTER DOORS
26 3/8" X 73" EACH BY ANTHONY
A. DOOR(S): FOR EACH DOOR PROVIDE
(7) 'D BEV-O-FLOW GRAVITY
SHELVES; UPPER (5) WITH SLIDES
AND LOWER (2) WITH ROLLERS
COMPLETE WITH UPRIGHTS
B. 9 DOOR(S): FOR EACH DOOR PROVIDE
360 B-O-F NYLA-LITE SHELVING SYSTEM
C. DOOR(S): 'D ROLLER CONVEYOR
AT FLOOR LEVEL
D. 4 DOOR(S): FOR EACH DOOR PROVIDE
27"D ANTHONY SHELVES
E. DOOR(S): FOR EACH DOOR PROVIDE
(2) 27"D ANTHONY SHELVES AND (4)
36"D MERCHANDISER SHELVES
F. DOOR(S): 'D DOUBLE DECK
ROLLER CONVEYOR
9. ICE CHEST BY VENDOR
10. CART RAILS W/ DISPLAY SHELF & SLAT WALL ABOVE
11. PROVIDE A 6"H BLACK VINYL BASE AT ALL
CHECKOUTS
12. ELECTRONIC ARTICLE SURVEILLANCE SYSTEM
PHARMACY DEPARTMENT:
13. PATIENT SEATING AREA: (4) SEATS
14. PROVIDE ELECTRIC FOR FUTURE ROBOTICS
15. COMPUTER TERMINAL
15A: INTERCOM PLUS TERMINAL
15C: TRAINING TERMINAL (IN TRAINING ROOM)
16. RX SINK AND CABINET
17. CRX CABINET
18. RX REFRIGERATOR
19. PROVIDE A CARPETED FLOOR WITH A RUBBER
RUNNER. RX UNDERCOUNTER INSERTS:
#1 - RX 3 DRAWER VIAL INSERT
#2 - RX 3 DRAWER FILE INSERT
#3 - RX OPEN INSERT
#4 - RX CONSULTATION COUNTER UNIT
#5 - RX PRINTER INSERT
#6 - RX 5 DRAWER FILE INSERT
#7 - RX OPEN INSERT WITH CPU SHELF
#8 RX OPEN CABINET
#9 - RX 10 DRAWER FILE CABINET
OFFICE:
20. PROVIDE TILED FLOOR & VINYL WALLCOVERING
21. UNDER COUNTER SHELF UNIT
22. PRINTER
23. LATERAL FILE
24. OFFICE COMPUTE
24A: P.O.S. TERMI
24B: AS400 TERMI
24C: OFFICE P.C.
25. TILL LOCKER
26. SAFE
27. TV & VCR (IN TRAI
STOCKROOM:
28. NEST-A-FLEX coTyoRCitY f Tukwila
29. GRAVITY CONVEY R Taw_
30, POWER ROLLER C NV PIVISIQL
- --
31, SEE ARCHITECTURAL DRAWINGS FOR EXACT
LOCATION & POSITIONING OF COMPACTORS
31A: TRASH COMPACTOR
31B: BALER
31C: CARDBOARD COMPACTOR
EMPLOYEE ROOM:
32. EMPLOYEE LOCKERS: (1) 48W COAT LOCKER W/
PERFORATED DOORS, (6) 6 TIER BOX LOCKERS &
(2) ADA LOCKERS W/ SAFETY VIEW DOORS
33. 5'-0"W X 2=2"ID EMPLOYEE COUNTER W/ (1) CABINET
34. EMPLOYEE ROOM REFRIGERATOR
(PROVIDE 32" CLEARANCE WHEN NEXT TO COUNTER)
35. EMPLOYEE ROOM SINK (IN COUNTER)
36. 4 MIRROR CENTERED ON WALL ABOVE COUNTER
MISCELLANEOUS:
37. "E" - ELECTRICAL OUTLET FOR FUTURE USE
38. VENDOR RACKS: REMOVE BASE DECK & SHOES;
(END PANEL TO REMAIN)
39. PROVIDE OPENING FOR ONE-WAY GLASS
(SEE INTERIOR ELEVATION FOR LOCATION)
40. NEWSPAPER RACK BY VENDOR
41. PICTURE CARE PLUS TERMINAL
FIXTURE LEGEND
1818 36 66 *
D. W. H.
G
GONDOLA
(EA. SIDE)
GE 18 39 *
GONDOLA D. W. H.
END
WS
. WALL
SHLVG
*DOES N'
,ABEINIII■11111SMIIIVAIMININSIk9P.IMENINNwine, MIGEMI1119■011.011,70SW
GENERAL NOTES
18 36 84 *
a W. H.
s REVIEWED FOR
CODE COMPLIANCE
AL APPROVED
INC ROO 07 200
ALL OTHER FIXTURES
ARE TYPICALLY
CALLED OUT DEPTH BY
WIDTH. EXAMPLE:
DT 30 48
DISPLAY D. W.
TABLE
INCLUDE STANDARDS, WOOD GROUNDS
OR FINISHED END PANELS
TYPE
NEW LOCATION II
NEW LOCATION
EXIST'G BLDG
REMODEL 111 LIQUOR EI OTHER
DEPARTMENT
GEN-
SALES
NO.
FOOD
MART
RX
WAIT'G
1 HOUR
PHOTO
2ND
FLOOR
NEW
EXIST'G
NEW
EXIST'G
NEW
EXIST'G
NEW
EXIST'G
NEW
TOTAL NEW
CADD PLOT:
10995-D1-06-17AUG07
VOID PLOT:
10995-D1-05-30MAR07
- SUPERSEDES
PLAN DATED:
PROJECT DA,
GENERAL ALES
PHARMACY
1 HOUR PHOTO
SQUARE FOOT AREA SUMMARY
SALES
5650
900
723
204
TOTAL EXST'G
TOTAL AREA: FIRST FLOOR
TOTAL AREA: OTHER LEVELS
GROSS AREA INCLUDING ALL
DEPARTMENTS & ALL LEVELS:
RX SHELVING LINEAL FEET:
I HEREBY CERTIFY THAT THIS
PLAN AND SPECIFICATION
WAS PREPARED BY ME OR
UNDER MY DIRECT
SUPERVISION AND THAT I AM
A DULY REGISTERED
ARCHITECT OR ENGINEER
UNDER THE LAWS OF THE
STATE OF WASHINGTON AS
SIGNIFIED BY MY HAND AND
SEAL.
REVISIONS
CERTIFICATION AND SEAL
STORE NUMBER 10995
RECEIVED
CITY OF TUKWILA
SEP 1 9 2000
PERMIT CENTER
PROJECT NAME
WALGREENS STORE
(NWC) HWY 99 & 144 ST
TUKWILA, WASHINGTON
DRAWING TITLE
FIXTURE FLOOR PLAN
SCALE: 1/8"=v-0"
DRAWN BY:
S.SLOWINSKI
DATE: 10/17/06
REVIEWED BY:
L. CUMMINGS
TA
:3111 FOOD MART
SECURITY LEVEL 4
MI 24 HOUR STORE El
SERVICE TOTAL TOTAL
EXIST'G NEW
1021 7,713
OF
DRAWING NO.
DI
DWGS.
..11•1•101•11■..1.=
900
95 LN.FT.
723
LIQUOR
BSMT
the
of a
EXIST'G
EXIST'G
NEW
EXIST'G
NEW
EXIST'G
435
7,912 1042 1168 9,975
gt
inn o
roved F
evislc
-
uty LIKvInia
ri• ft rilti101 M
L.A..4/ I La." g #I w
+ t, gt
•ti Oijt orior ao royal of
_PralPrir
s wi require a
inn OVIP.W fees.
3finfoldr
t
Ant" ess,7",
'VOW riaks
or rtlinnor.
talons is acknorAccioz
Mechanical
ectricai
DATE BY DESCRIPTION
CONST
204
435
9,975 SQ.FT.
0 SQ.FT.
9,975 SQ.FT.
J