Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M08-240 - FIDELITY INVESTOR CENTER
FIDELITY INVESTOR CENTER 304 STRANDER BL M08 -240 Parcel No.: 6364200010 Address: Suite No: 304 STRANDER BL TUKW Cityf Tukwila Tenant: Name: FIDELITY INVESTOR CENTER Address: 304 STRANDER BL , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: STEVEN DESIMONE Address: 711 ATLANTIC AVE , BOSTON MA Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Contractor: Name: OKITSU CONSTRUCTION INC. Address: 1428 WHITWORTH AV S , RENTON WA Contractor License No: OKTTSCI959L8 MECHANICAL PERMIT DESCRIPTION OF WORK: MECHANICAL SCOPE FOR TENANT BUILD OUT OF THE FIDELITY SHELL & CORE Value of Mechanical: 130,000.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat /Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC -10/06 EQUIPMENT TYPE AND QUANTITY 0 0 0 14 0 0 0 0 0 0 0 0 0 0 * *continued on next page ** M08 -240 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 607 - 956 -3661 Phone: 206 714 -9969 Expiration Date: 06/28/2009 M08 -240 01/23/2009 07/22/2009 Fees Collected: $1,482.50 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 49 Thermostat 12 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 01 -23 -2009 Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this pe construction or the perf Signature: Print Name: doc: IMC -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us oes not c i , D:),,k y c ok -5L& Ltuiru, Permit Number: M08 -240 Issue Date: 01/23/2009 Permit Expires On: 07/22/2009 Date: l -.):1-og resume to give authority to violate or cancel the provisions of any other state or local laws regulating rk. I am authorized to sign and obtain this mechanical permit. Date: (' 3 o 1 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M08 -240 Printed: 01 -23 -2009 Parcel No.: 6364200010 Address: Suite No: Tenant: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 304 STRANDER BL TUKW FIDELITY INVESTOR CENTER 4: Readily accessible access to roof mounted equipment is required. PERMIT CONDITIONS 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. * *continued on next page ** Permit Number: Status: Applied Date: Issue Date: M08 -240 ISSUED 09/30/2008 01/23/2009 M08 -240 Printed: 01 -23 -2009 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • • City of Tukwila 5 . D'� Print Name: �� ` � ` doc: Cond -10/06 Date: M08 -240 Printed: 01 -23 -2009 SITE LOCATION Site Address: 131.u7. Suite Number: Floor: Tenant Name: ripe r,/ rat' / nt v �;sT M NT New Tenant: LxJ Yes ❑ ..No Property Owners Name: Wt A JTi FC -.-t, N rE tr l-L Mailing Address: l( go( 1 Ai it,.."--,0- l2( 81.ul> 1 1°ti rt.aZ. ,A-NS t s City CONTACT PERSON - who do we contact when your permit is ready to be issued Name: -STC N PF -31 MbN G Mailing Address: '7 i' I kTLA 41 IC_- / r .% . 'f E -Mail Address: 4pg6I PZDN C= TO aroNt'o . cO l Fax Number: GENERAL CONTRACTOR INFORMATION - (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) $1•1 'It O fl , 7-601 t /k ,/E h,,► X50 fkT L A as z) - City State Zip Day Telephone: ( Z o6 > 316 E -Mail Address: fkre-11- -. P -IGiY 8 t-Dti126 .Cdr Fax Number: (2b4) S$2 - ( t t{ Contractor Registration Number: 15"8 k-41 Company Name: Mailing Address: Contact Person: E -Mail Address: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: i www. ci. tukwil a. wa. us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Building Permit No. Mechanical Permit No. t40 9-.2 4-0 Plumbing/Gas Permit No. Public Works Permit No. Project No. POO(�l5 King Co Assessor's Tax No.: (For office use, only) 361--uo-uo ( 0 State `too Z5 Zip Day Telephone: C i/ 964 3 66/ F-tA ozu J State Zip (C/7) 3`t S 'ZS c) Expiration Date: 't 4- / 4 " ARCHITECT OF RECORD -All plans must be wet stamped by Architect of Record Company Name: G V•eoi2- MailingAddress: 0 41 seA-C.ON mil- V 7ttAgpFt,:ce- & I5 7 K 1W Oz-i4.8 State Zip Day Telephone: ( (7) 4:// - 57Cx� Fax Number: (6/7) C/9' - 57a/ Contact Person: f AB t,0 661I.1 A .. _+ r r —g a,, fCpI' tfi6 Q:Wpplications'Forms- Applications On Line\3.2006 - Permit Application.doc Revised: 9 -2006 bh Cati City ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: , 'b FA-MO S - -Ga r .s..> qv $oi Fr — o1V MA 67,24 x- "/ City State Zip Contact Person: P1A2i -- A Mt Le) Day Telephone: �i7) 315 -1 i3 Gg. E -Mail Address: KArM co ec 2.-L7- naa es , C.o' l Fax Number: (6'( 7) "-t4 - of 2z4 Page 1 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser I4 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat `i , 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor i ll Mounted Heater '�1 * Ventilation System Wood/Gas Stove 30-50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig /Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm/Ind MEGHANI'CAL PERMIT _INFORMATION' = X206-431 -3670 • MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $ (30 r)Co rep A Nr Scope of Work (please provide detailed information): gC - I J I Girt -- f J 1 L - — OF f i f7 &- r`f -5 tt JL - Low Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New ...X] Replacement .... ❑ Fuel Type: Electric Gas ....E Other: Indicate type of mechanical work being installed and the quantity below: Q:Wpplications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Page 4 of 6 PERMIT APPLICATION NOTES - Applicable to. in this application . • Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER AUTH RIZED AGENT: Signature: Date: 9 74 /' v Print Name: 17 W Off N l`s Mailing Address: '7 N t r-Nym. I Date Application Accepted: -30-o `� Q: Wpplications\Forms•Applications On Line\ -2006 - Permit Application.doc Revised: 9 -2006 bh Day Telephone: (di 7) L - 346) Bo` -e?Ni /.1, A- O City State Zip Date Application Expires: 3 -30-09 Staff Initials: (be I Page 6 of 6 Receipt No.: R09 - 00127 Payee: OKITSU CONSTRUCTION ACCOUNT ITEM LIST: Description MECHANICAL - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1828 1,186.00 RECEIPT Parcel No.: 6364200010 Permit Number: M08 -240 Address: 304 STRANDER BL TUKW Status: APPROVED Suite No: Applied Date: 09/30/2008 Applicant: FIDELITY INVESTOR CENTER Issue Date: Initials: WER Payment Date: 01/23/2009 09:24 AM User ID: 1655 Balance: $0.00 Account Code Current Pmts 000.322.102.00.0 1,186.00 Total: $1,186.00 Payment Amount: $1,186.00 1828 01/23 9707 TOTAL 1186°00 doc: Receiot -06 Printed: 01 -23 -2009 Parcel No.: 6364200010 Address: 304 STRANDER BL TUKW Suite No: Applicant: FIDELITY INVESTOR GROUP Receipt No.: R08 -03390 Payee: BNBUILDERS • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 36740 296.50 ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES RECEIPT Account Code Current Pmts 000/345.830 296.50 Total: $296.50 Permit Number: M08 - 240 Status: PENDING Applied Date: 09/30/2008 Issue Date: Payment Amount: $296.50 Initials: WER Payment Date: 09/30/2008 09:09 AM User ID: 1655 Balance: $1,186.00 ., +P7` Y;/3O x'707 TO 27o.50 doc: Receiot -06 Printed: 09 -30 -2008 COMMENTS: CI •.5",70 4Cp S'//icr 1)&21.>/U — Al O , /it- ) Arlides 047..e CI$ del/ e e Ai »f Pt Date Called: 3) 5F i4 Ay & ,Gi, 4;v - es- - ed . _Live of lei V 'j/ Special Instructions: V Pr i)-1 ( p/q, , e'-/ / d c eJ p.m. Requester: Project: / rl( /if4 /J/✓tsaov Type of Ins fiction: of / Ad ress: 76 9 .3 Date Called: Special Instructions: Date Wanted: `�' .L/ — / 7 — d c eJ p.m. Requester: Phone No: ,R.D6 --. X. :37/ 7 /7L by-2z, INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. 0 Corrections required prior to approval. spect r Date: 61 0.00 REINSPECTION FEE Prior to inspection, fee must be aid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: PERMIT NO. Project , / Type of Inspection: Address: I f Date Called: Special Instructions: • ` ; Date Wanted: .� — /Ur O ► Requester: Phone No: 2 c- 7 • INSPECTION RECORD Retain a copy with permit / -2i(e) PERMIT NO. INSPEC�LO NO. CITY OF TUKWILA BUILDING DIVISION eg 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. •y COMMENTS: • (specto5. 0 0 REINSPECTION FEE I14 f d U 1d att6300 Southcenter Blvd., Suit 1 J Reipt No.: Date. !Prior to inspection, fee must be 00. Call to schedule reinspection. Date: COMMENTS: p i i . / / y/9,-(/ 2 ,2f Arm s - ,Pd7, A — 4pticJc7 Address: , a lc ; /2 - tt .. -Is A J- -400/4/ Date Wanted: ,� -2 z Requester: Phone No: 2 - 7 3 ' 7 / 7 Proje �- 7—/r/ - /� / -- v v� Type of I, pection: / d)/ I i - PU Address: Date Called: • , Special Instructions: $ Date Wanted: ,� -2 z Requester: Phone No: 2 - 7 3 ' 7 / 7 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION - 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. Inspecto Receip 421 Corrections required prior to approval. S Dat 2- 3 EINSPECTION FEE'' EQUIRED. Prior to inspection, fee must be p - d 6300 Southcenter Blvd., Suite 1.0. Call i schedule reinspection. !Date: COMMEN . - Type Ad / Address: f ! 3 04 co fl ici p 9 /Pt 44. c,4 r .5;4 2 t21/%0'( 1...e.,g7 ., 6/ o i 44,, Z7,-. /... 0 41-0 3 . -- AO✓ce I' . 0 S 4; r ' Proj ^ L n rS Type Ad -, ctiQn: J Q Address: f ! 3 04 co fl ici Date Called: Special Instructions: Date Wanted: ca,na.: Z - Z c3 i D p.m. Requester: . Phone No: " 2 CO -'713 - 3 717 INSPECTION NO. IN RECORD Retain a copy with permit /1. o k -2o PERMIT NO. CITY OF TUKWILA BUILDING DIVISION F.- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per des. El Corrections required prior to approval. LI $60.00 RE PECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: IL AIRIEST Co., Inc. NOTES: Airtest Co Inc Preliminary Test and Balance Report FIRM: Airtest Co Inc PO Box 86 Issaquah, WA 98027 PHONE: 425 - 313 -0172 FAX: 425 - 313 -5735 PROJECT: Fidelity Investments - S. Seattle Branch 304 Strander Blvd. Seattle, WA 98188 DATE: 4/13/2009 PROJECT #: 09- 3005 -1 CONTACT: 7 10 Preliminary Test and Balance Report 1 of 12 ' .,t.System / ( .' .,1 s ed .:,;',,, j - --,-, .„--_ Area ry ,. ,,..--. „,,,, •`outhittyiie< , . aiiel/ -: , ‘,.,.! 6 I '.. % Diiigli' ,.. ,.*. '''CFM .. , .;.';: ..':.. , • ' '-.g.Rea - . . . . ,, • Deviation. SA-01 Conference 109 CD 8 RD 175 140 80.00 SA-02 Conference 109 CD 8 RD 175 140 80.00 SA-03 Conference 109 CD 8 RD 175 150 85.71 SA-04 Conference 109 CD 8 RD 175 140 80.00 SA-05 Utility RM 113 CD 6 RD 50 40 80.00 krIll ' ,ti` ;4i.,:,;,,,,- :.„.., .' . t ; ',''' 0 /...'‘ Totals'.- ' ;, , '05.c: .... .., :.;. I '' a .,....,.....6 5qe.: ,, t. • ri, ..,..:.: ;,.,: 'e4,1 ,v.,-. :...i. 7 et 750 -. .h 4 4 ., , ,,,..; .. • -...,-. ' ,,. ,, ;610.:', '.'. _ , !, ... .''.:: 81: -, ..,, . . 4. AIRTEST Co., Inc. Air Handling Unit Report PROJECT: Fidelity Investments - S. Seattle Branch LOCATION: Seattle, WA PROJECT #: 09-3005-1 SYSTEM/UNIT: Existing AREA: * Notes SYSTEM/UNIT: Existing / FB-01 AREA: Womens 134 Existing / FB-01 Supply Outlet Summary * Notes Airiest Co Inc DATE: 4/13/2009 CONTACT: Tested By: Jeff Kitt Test Date: April 08, 2009 !Existing / FB-01 10-Apr-09 Jeff Kitt VAV proportioned to available air flow, vfd at 100% Preliminary Test and Balance Report Tested By: Jeff Kitt Test Date: April 10, 2009 • Air Test - er Des. Fan/Heat CFM 750 CFM Act Fan/Heat CFM 610 CFM Design Primary Max CFM 750 CFM Actual Max Primary CFM 610 CFM Design Primary Min. CFM 225 CFM Actual Primary Min. CFM 230 CFM 2 of 12 VAV Type Series VAV Address 6 Box Inlet Size 10 RD K Factor 3.785 •I''' .,„ - .,.: , ' ;.; • : :; '..,::' '€ - " , {i"."'irf• - • 14, c-.... - :: ' ' , ,, vg a Fan Speed dj.© med AIRTEST Co., Inc. Air Handling Unit Report PROJECT: Fidelity Investments - S. Seattle Branch LOCATION: Seattle, WA PROJECT #: 09-3005-1 SYSTEM/UNIT: Existing AREA: * Notes SYSTEM/UNIT: Existing / FB-01 AREA: Womens 134 Existing / FB-01 Supply Outlet Summary * Notes Airiest Co Inc DATE: 4/13/2009 CONTACT: Tested By: Jeff Kitt Test Date: April 08, 2009 !Existing / FB-01 10-Apr-09 Jeff Kitt VAV proportioned to available air flow, vfd at 100% Preliminary Test and Balance Report Tested By: Jeff Kitt Test Date: April 10, 2009 • Air Test - er Des. Fan/Heat CFM 750 CFM Act Fan/Heat CFM 610 CFM Design Primary Max CFM 750 CFM Actual Max Primary CFM 610 CFM Design Primary Min. CFM 225 CFM Actual Primary Min. CFM 230 CFM 2 of 12 . v. e..,... ..�- r !System i Unit, ^ § t *'c� m y,� # . ,.., ' t`+. �° Y .. K,...cWr Area servedi' Y., y , �` $$ � . `ter Ft 1 �`:t ./� a..r �'4... . { S. ry'V l'rP.... .ruu., TOutlet Type r,' 3, JS-- ; : At .ah Y.-� r'�. 7. Size'14 W / , ri,7 r ti " D ,' ' k r .+lit . 'h P ".v > , W e Design ri r'cf. t ti 4 C FM, .rt.{6. ., Mt ;k. >` LF,P ' ,:Final pr ..3 , Reading .... :b � °i6 Final roF;' t ,- D evi a tio n ! .. _ . . ... SA -01 Office 105 CD 6 RD 115 105 91.30 SA -02 Office 106 CD 6 RD 115 105 91.30 SA -03 Office 107 CD 6 RD 115 105 91.30 SA-04 Hallway 112 CD 6 RD 30 30 100.00 SA -05 Hallway 116 LD 8 RD 75 70 93.33 SA -06 Womens 134 CD 6 RD 75 70 93.33 SA -07 Mens 132 CD 6 RD 75 80 106.67 . 1 � ' ;' ; Totals , r W i . g � • !r.' " t 600 445 65 . m'0, 94;, % 7 ,. x S / Unnit :`•'�„rk't" ry, ,. u , �,. a Area served . - ^t , s b ; M' ��ss n S ._ .y `. • ,p..tf xkc . . . Outiet Type y ur '� . ' ;' r z YSize !, � ? u ,LY TDesign »Fr ` a . CFM eee, . ', ° ¢1,F nal Reading Fr.:yr „ % Final t De SA -01 Fan Speed adj.@ med Office 120 CD 8 RD 130 140 107.69 SA -02 Hallway 116 LD 6 RD 60 60 100.00 SA -03 Office 123 CD 8 RD 160 150 93.75 • Y e `.' ' ' , r a 4 v" wt rG+ 7 . K . a4 T o tals r " � aV° ��' Y 35 q t` , ,..,.. re;;:,,,? Y !Ale 100 ° 1 h { ql r> ` Un' it Data:F ta� "�sfi VAV Type VAV Address Box Inlet Sae K Factor Series 10 8 RD 4.815 <`,1 s HK ; Test Da te" r ,rsii ' 9 1'.... ` ...YU t,. ...� Fan Speed adj.@ med �..,,� R�t •� sss� Unit Data 4 , DTs `,,' re: .. �fJ • . . w k' r :''':, , 0,./i nu :. ➢, �i'4{se", r.., . ^"x2 . .A., '"s. , VAV Type Series VAV Address 13 Box Inlet Size 8RD K Factor 2.667 <`,1 s HK � qq S v , TT est Data' , ''. ' :v. £ ki a :Wl `"1'fh -'S'V W -, r,t. -s;.•t ■ r'A!. >.r'.i.5 +{ ?S ?r r '. r , Fan Speed ADJ. @ MID AIRTEST Co., Inc. Air Handling Unit Report PROJECT: Fidelity Investments - S. Seattle Branch LOCATION: Seattle, WA PROJECT #: 09- 3005 -1 SYSTEM /UNIT: Existing / FB-02 AREA: Support 131 Existing / FB-02 Supply Outlet Summary * Notes SYSTEM /UNIT: Existing / FB-03 AREA: Support 131 Existing / FB-03 Supply Outlet Summary *Notes A /Kest Co Inc Preliminary Test and Balance Report DATE: 4/13/2009 CONTACT: Tested By: Jeff Kitt Test Date: April 10, 2009 irlest'Data Des. Fan/Heat CFM 600 CFM Act. Fan/Heat CFM 565 CFM Design Primary Max CFM 600 CFM Actual Max Primary CFM 565 CFM Design Primary Min. CFM 180 CFM Actual Primary Min. CFM 175 CFM Tested By: Jeff Kitt Test Date: April 06, 2009 FPS 4 Airlest Datai 4 • Des. Fan/Heat CFM 350 CFM Act Fan/Heat CFM 350 CFM Design Primary Max CFM 350 CFM Actual Max Primary CFM 350 CFM Design Primary Min. CFM 105 CFM Actual Primary Min. CFM 115 CFM 3 of 12 System'/ Unit ���•OU' r `� A _ s t r, a f 9 ti, r An3a Served } r5 j * N ;i ���; 4 'x }� ; S T$'Y C D rr � f v; �,I..1.0 t _ .. y Outlet i Type C X`�'`-0 �C E' A �3 x' 3 Size'LxW / 'R i Vi i. - ri a� : tr , d Design` , 1 t:,.,`. • T) '�'j Fy;' tk' .0 ,.!AA0 w.., ". k Final ' 74 7 : Readingm i'91 w ' 96 Final . ate' W S' De x SA -01 Office 124 CD 8 RD 160 135 84.38 SA -02 Office 125 CD 8 RD 160 140 87.50 SA -03 Office 128 CD 8 RD 160 135 84.38 SA-04 Office 127 CD 8 RD 160 145 90.63 ?4 �rti g, d�� Y i'l.I: n�^jZ�a �;#��('' y Iw i e i s a.Y', I�b'S:;Li'1 ,Y E.a.:F� -- �tlt °TS4J nVf4g:TOlOIS -,{ , x.t . " ' �,,.'} � K. f' .. i.. +l;F `i ww c : ',� �'c�. ?i Yt.. •1 �6 - ' 'f - c kA.t..r +,cif tJ� 4 i 5 &A 1�� IJ+. �.:t µ ., ± 87 %a dP'�.:n System, Un 4� n ' � c ,ca r. y�? � % A rea S erved; i em ` ; ' :: fix, ' �` ". :. .. ,. " SOutte d _ ' � SueLxW / i a rc. D� k rr � .. :n+ 'Alin y p � CFM P _ F .... x Y Reading . ... ' g'it Final' `' .. Deviation A .« ,, , z " SA -01 Office 117 CD 8 RD 125 130 104.00 SA -02 Office 118 CD 8 RD 125 130 104.00 SA -03 Office 119 CD 8 RD 125 130 104.00 ,'�x,5 r c t 4+? •.t'tT ... �r'� �� ar� °4 . t +�' a -S �'�,�':`` � s�� :.+ :r.,'2.°. t � � 1 t .c,. �9�.�s �f�, �: ,i �^�_a -4 a` t•F?� .b. _f. ,. ��,+�<.� i.7 ;x�ra t � a t��� ..., 1^ 3 90�� '� Y-r. ° �,:� ",.104 /o T�. .n� .. Y r ° " e w � p Umt Data 0;� , 6 'tea. C's - , RE r... tY ,,,g i '.∎ . . .: . Y _. _.. -' r VAV Type Series VAV Address 14 Box Inlet Size 8 RD K Factor 2.469 PFkk , , � ° *Nest Dat " " " ... • Fan Speed ADJ. @ MED. AIRIEST Co., Inc. Air Handling Unit Report PROJECT: Fidelity Investments - S. Seattle Branch LOCATION: Seattle, WA PROJECT #: 09- 3005 -1 SYSTEM /UNIT: Existing / FB-04 AREA: Support 131 Existing / FB-04 Supply Outlet Summary * Notes SYSTEM /UNIT: Existing / FB-05 AREA: Breakroom 130 Existing / FB-05 Supply Outlet Summary * Notes Aintest Co Inc Preliminary Test and Balance Report DATE: 4/13/2009 CONTACT: Tested By: Jeff Kitt Test Date: April 10, 2009 a iryTest JO Des. Fan/Heat CFM 375 CFM Act. Fan/Heat CFM 390 CFM Design Primary Max CFM 375 CFM Actual Max Primary CFM 390 CFM Design Primary Min. CFM 115 CFM Actual Primary Min. CFM 115 CFM Tested By: Jeff Kitt Test Date: April 10, 2009 irTest; Data Des. Fan/Heat CFM 640 CFM Act Fan/Heat CFM 555 CFM Design Primary Max CFM 640 CFM Actual Max Primary CFM 555 CFM Design Primary Min. CFM 195 CFM Actual Primary Min. CFM 190 CFM f Existing / FB-05 7 -Apr -09 Jeff Kitt VAV Proportioned to available air flow, vfd at 100 %. 4 of 12 i z �- .... . Urnt.Data, i x -'v Fv �"9+c xln..tr�Tt ^'• fi . �"•. J�a.A*... "'i .. ��.L"Fal�.`�r. +f'i' °'f.t�fit -. - .�'.� VAV Type Series VAV Address 15 Box Inlet Size 8 RD K Factor 2.561 PFkk y .!,.. . l4"" ` A na r ?� 4' 4 � T est Data X9•,1 an T F �� h ff�s -0 �a ..v ...i t'.3i •'.."I:4...J f j fq �, j: Fan Speed ADJ. @ MED AIRIEST Co., Inc. Air Handling Unit Report PROJECT: Fidelity Investments - S. Seattle Branch LOCATION: Seattle, WA PROJECT #: 09- 3005 -1 SYSTEM /UNIT: Existing / FB-04 AREA: Support 131 Existing / FB-04 Supply Outlet Summary * Notes SYSTEM /UNIT: Existing / FB-05 AREA: Breakroom 130 Existing / FB-05 Supply Outlet Summary * Notes Aintest Co Inc Preliminary Test and Balance Report DATE: 4/13/2009 CONTACT: Tested By: Jeff Kitt Test Date: April 10, 2009 a iryTest JO Des. Fan/Heat CFM 375 CFM Act. Fan/Heat CFM 390 CFM Design Primary Max CFM 375 CFM Actual Max Primary CFM 390 CFM Design Primary Min. CFM 115 CFM Actual Primary Min. CFM 115 CFM Tested By: Jeff Kitt Test Date: April 10, 2009 irTest; Data Des. Fan/Heat CFM 640 CFM Act Fan/Heat CFM 555 CFM Design Primary Max CFM 640 CFM Actual Max Primary CFM 555 CFM Design Primary Min. CFM 195 CFM Actual Primary Min. CFM 190 CFM f Existing / FB-05 7 -Apr -09 Jeff Kitt VAV Proportioned to available air flow, vfd at 100 %. 4 of 12 $System /Unit :, ; �, „,... x iT Area Served e x , !' t.i`' .. ; � ,fit . ,a� :t , •.x.. ?*a.. >1i.t'•"�' an• Outlet Typed j ' i r . ; , • A5•.4 1 _ :, •fi: iz S e LiW / , _` �.. >r�,a•�+ . D es-iiii ' CFM *" � . !hit Final A . s SReedmg ' t, -r ... , ,,,,,• % F aI s De Y . ..� .. _. SA -01 Hallway 116 LD 6 RD 75 65 86.67 SA -02 Support 131 CD 8 RD 185 155 83.78 SA -03 Hallway 122 LD 6 RD 70 60 85.71 SA-04 Breakroom 130 CD 15 x 15 255 210 82.35 SA -05 Hallway 122 LD 6 RD 70 60 85.71 SA -06 Office 129 CD 6 RD 95 80 84.21 SA -07 Office 128 CD 6 RD 110 90 81.82 `'�y" i ?,- ';7".� � ;� I{•a.���� ;t .T Otal3 . •5 ...� '�4..v'e � -}.7�. .'tea '.i �h' . 4 - '.� <.:.+�ry�;..: tkjy � r- t :, et# ?G• ,, , 72 t�•:,"F:>'m %'R rrd'.. `3r'3Y 84% �. Y System %.Unit . F ,. . , 4u , 3 d' " # . w N'�v? b W.tk� y ttr � 'a'; ' A rea Served`' ,`P :.U r � d ' 7 .�. ''4 -i ✓ xn� n r g ' u ai a � _.d k� � � ;rt s .. �+ .7.,d5C �r FOutl efT 7. �.} r ypeT :` SizeyLxW /� y .. {f . ; , ro , , " i i' �!��iS� a Desi n i f r'« . r 9 fat ;aaCFM A' p 't�'a ., e. f:t7.� r 'F ina l )? ; Reading r e. a . ....�.. � 1 96 Final ��`? q., r..` #. Deviatio ?i' . ....... ,.< SA -01 py' ,l ^,fig`.` vv55tt Operations 135 CD ,._ ' � . r l n1. r1.' x,'t! 3 ; Test D at a 4, ,,itl , « r 'fA;S r''..N:' • -Fb 'r 'T :`.k,: dR: 12 RD Fan Speed 450 365 81.11 SA -02 Operations 135 CD 12 RD 450 370 82.22 t ^ ffi n tq: -" 1x> r � h r+ «s�,�.* , t .y, TOtals ta' , a r +�4 ..t .. ... c 5, . 1. �r, rS x a. ;r y 900 ,as4;: #r'7 pck o , .St. :d 8 2% {,.,`� : K,; X b•: .• '''' ' 8 f; 3 s., . , s : e * t � U rnt Data N .dtYr l4 k �.. �,t�,°j .a kY'. \w., ,R �.A �: .,J�n���. VAV Type Series VAV Address 17 Box Inlet Size 10 RD K Factor 2.611 nrt Dat« ,;M ri -zf. `§J i VAV Type VAV Address Box Inlet Size K Factor Series 16 10 RD 3.412 py' ,l ^,fig`.` vv55tt "'t •+ � '-' r�.°< a'd :' .P 1 ,._ ' � . r l n1. r1.' x,'t! 3 ; Test D at a 4, ,,itl , « r 'fA;S r''..N:' • -Fb 'r 'T :`.k,: dR: Fan Speed adj.@ max '''' ' 8 f; 3 s., . , s : e * t � U rnt Data N .dtYr l4 k �.. �,t�,°j .a kY'. \w., ,R �.A �: .,J�n���. VAV Type Series VAV Address 17 Box Inlet Size 10 RD K Factor 2.611 3� Y -'',, ,.. .. . ?' � !.p :w ;x s :S ?r.1 _ _#` .,fTeSt Data Gq ,'I':s�.�,. ri -zf. `§J i Fan Speed ADJ. @ MAX AIR ZEST Co., Inc. Air Handling Unit Report PROJECT: Fidelity Investments - S. Seattle Branch LOCATION: Seattle, WA PROJECT #: 09- 3005 -1 SYSTEM /UNIT: Existing / FB-06 AREA: Breakroom 130 Existing / FB-06 Supply Outlet Summary * Notes SYSTEM /UNIT: Existing / FB-07 AREA: Operations 135 Existing / FB-07 Supply Outlet Summary * Notes Antest Co Inc Preliminary Test and Balance Report DATE: 4/13/2009 CONTACT: Tested By: Jeff Kitt Test Date: April 10, 2009 it Test'Data Des. Fan/Heat CFM 860 CFM Act. Fan/Heat CFM 720 CFM Design Primary Max CFM 860 CFM Actual Max Primary CFM 720 CFM Design Primary Min. CFM 260 CFM Actual Primary Min. CFM 255 CFM (Existing / FB-06 10- Apr -09 Jeff Kitt VAV proportioned to available air flow,vfd at 100% Tested By: Jeff Kitt Test Date: April 10, 2009 1. ;, Airjest,Data Des. Fan/Heat CFM 900 CFM Act Fan/Heat CFM 735 CFM Design Primary Max CFM 900 CFM Actual Max Primary CFM 735 CFM Design Primary Min. CFM 255 CFM Actual Primary Min. CFM 250 CFM (Existing / FB-07 7 -Apr -09 Jeff Kitt VAV Proportioned to available air flow, vfd at 100 %. 5 of 12 System / Unit � ' + Y s ;. i . ,, Are S erved. ` « ti a 's F ..e ..�'fi Outle Type I0-- :g.*4 Sze Wq / Des9j ' i CFM nal '� Fi Readm K 9aa 7�%F nal t�,Devi , ? SA -01 Managers Office 103 CD 8 RD 150 155 103.33 SA -02 Office 104 CD 6 RD 115 110 95.65 i , yv:� " x �:'t ?�zk� �„ },.3'i'Sn e�A ,:,.. . ' ,. ?��.�'`�' .� :�c t�+� Totals � i t 4 fi„ _�� -� ¢ �'��? �:�rr xi � �`'�3�.i 265, ��� �v :265;��`:, '2.,„„,,,:l09,„.,., �:: 9 f° VA .. s. �� Unit Dat !a 'acf j,l Y�4fi \-ww, •YS,�`. 4 ^s. _,. " a:,,. _,et `.... ` ` trC. �!i •R3: VAV Type VAV Address Box Inlet Size K Factor Series 18 12 RD 1.851 VAV Type VAV Address Box Inlet Size K Factor ,y �'J T ` v}� � Y r = fi '. S est`Data _3M?�� . : " �t0".., .r +Z .1..i, ,.. et. `1. :. Fan Speed ADJ. @ MED. Fan Speed NT..H3.: . °Unit Data, . ,<A+bp. K , VAV Type VAV Address Box Inlet Size K Factor Series 19 6 RD 2.896 Final°A Read ing. .,tea ., �. . .te a.. all Deviati 3 ::.. .,.. , $kitiiiijiiii Data . ..,.nx Hallway 108 Fan Speed adj.@ low 280 ystem %Unit$AreaSeed 4 G • • , -ti y u..! - 5= '::.. 1 Ou letTypei $ S , 52c e- , tf: SizeLu % 4°. .,4 D -� vT .... .:i§ . 'a Desig W.41 • i ? 5 ,... Final°A Read ing. .,tea ., �. . .te a.. all Deviati 3 ::.. .,.. , .:.53 _i�.?.a 1 cASt; , . SA -01 . ..,.nx Hallway 108 LD 10 RD 280 275 98.21 SA -02 Hallway 108 LD 10 RD 280 280 100.00 SA -03 Hallway 108 LD 10 RD 280 260 92.86 SA-04 Hallway 108 LD 10 RD 280 270 96.43 SA -05 Hallway 108 LD 10 RD 280 260 92.86 . s ' ; . .1.1700 - 1 ' J . tals- ° :1- ,.x. a -".Y +' ta71.;19,07 ... 1 .- aw969f°$.' . AIRTEST Co., Inc. Air Handling Unit Report PROJECT: Fidelity Investments - S. Seattle Branch LOCATION: Seattle, WA PROJECT #: 09- 3005 -1 SYSTEM/UNIT: Existing / FB AREA: Operations 135 Existing / FB-08 Supply Outlet Summary *Notes SYSTEM/UN/T: Existing / FB-09 AREA: Operations 135 Existing / FB-09 Supply Outlet Summary *Notes Aiftest Co Inc Preliminary Test and Balance Report DATE: 4/13/2009 CONTACT: Tested By: Jeff Kitt Test Date: April 10, 2009 rA iriTest Des. Fan/Heat CFM 1400 CFM Act. Fan/Heat CFM 1345 CFM Design Primary Max CFM 1400 CFM Actual Max Primary CFM 1345 CFM Design Primary Min. CFM 420 CFM Actual Primary Min. CFM 435 CFM Tested By: Ron Guidi Test Date: April 10, 2009 R =. IN Test • Des. Fan/Heat CFM 265 CFM Act. Fan/Heat CFM 265 CFM Design Primary Max CFM 265 CFM Actual Max Primary CFM 265 CFM Design Primary Min. CFM 80 CFM Actual Primary Min. CFM 80 CFM 8 of 12 --- ,-- ----•,,-; . .::-; •'• • '4l‘Q. ." "0'4 — •,.tiz • ''''''' ' 1-4*; .4 lOutHetTYpe. ' . " ' ` 4 *V ;,4'..... Siza Lx Wlt ' l' ..: u• • ,z• .. /sx-„. • - ye De s i g ii rf ;?. • i .4 ttl:-. CFNI .,, .4,1 ,,,,._ ,, 4 F . ,,ii33 4- 1 .1 4..fteadfn gp: ., . . .' Fi Deviation :14- ..., .......-. SA-01 Lobby 101 LD 8 LD 200 2 10 RD 280 240 s 85.71 SA-02 Lobby 101 LD 10 RD 280 260 92.86 SA-03 Lobby 101 LD 10 RD 280 240 85.71 SA-04 Lobby 101 LD 10 RD 280 230 82.14 SA-05 Lobby 101 LD 10 RD 280 260 .86 . I . A t 'i - '• , - --, '" v- r' 5 -*t4= 4- - -, *--3;Jotals‘.?, 7 '... tpge•kr NI , , „g . , .,C.c. `190".27 . _'" :, 4`.,. , 1 230 -'+.••"- - 1 i,.. , . pa 3 92 . , -.41. , ...t•ini —. , .%ii:/,...??...7:,..‘".- - q...lir!, 4 41 0 'i. 0, . •1*-. it Aqi,,-..t,;;9'..1..K..11:7i:ftei,-..:',.,14:&,,.'i.e.,•.,..,,..):?•,,..;'1',.' '';'`..7.4 A. 1 . I ...... V -/e . . . VAV Type VAV Address Box Inlet Size K Factor Series 20 12 RD 4.037 b , T" - r, - ,-- 1 -7 ,,i;p:i.: ' , -4' ii -`. .- f,.....‘ -'4‘• ..,-„ -- -- - • IiiiiiFt..- , V - k , i ; ' ,- .1.,ti.g . i 5 ..• . N ., , i'Aws• . - .y , ...14 , 4gt. - )q , ,,-* = .. .:•iltr'.h.f.,• a ',..,..t....,- • •..... , .. Fan Speed ADJ. @ MED. !c! .'",••,:' : - .- i:0:i ••: ,,, -:,-,. 4 ^-: i. 41 ,, ,r, li"' ...c. S VAV Type Series VAV Address 21 Box Inlet Size 6 RD K Factor 2.143 . ,.t ? , - ---'," ' -'''' ‘ A ' 1 r " i 4 , ; , ...t.f,iirt , :; --7.-"..:,44,...-....., A ::=--,...: , .,... Fan Speed adj.@ med - :. 2 :-.,....,.'%,,,' F.,.. ",..i,cf i r 'Biitern . itinft , ,-,. - Aeft rae,tv i ._ .. < 1 1- CnifletiTy`Wi, ' 'SSIze,' ,,14W . . ) ) ... ",* ' -6 T1, 431 :, „ „% F),^ili '..g - - :. 2 :-.,....,.'%,,,' F.,.. ",..i,cf i SA-01 T Transaction 101A L LD 8 8 RD 2 200 2 220 1 110.00 k a: Z s AIRTEST Co., Inc. Air Handling Unit Report PROJECT: Fidelity Investments - S. Seattle Branch LOCATION: Seattle, WA PROJECT #: 09 SYSTEM/UNIT: Existing / FB-10 AREA: Operations 135 Existing / FB-10 Supply Outlet Summary * Notes • SYSTEM/UNIT: Existing / FB-11 AREA: Operations 135 Existing / FB-11 Supply Outlet Summary * Notes Akest Co Inc Preliminary Test and Balance Report DATE: 4/13/2009 CONTACT: Tested By: Jeff Kitt Test Date: April 10, 2009 A i r Test Data 0‘" • Des. Fan/Heat CFM 1410 CFM Act. Fan/Heat CFM 1230 CFM Design Primary Max CFM 1410 CFM Actual Max Primary CFM 1230 CFM Design Primary Min. CFM 420 CFM Actual Primary Min. CFM 395 CFM !Existing / FB-10 8-Apr-09 Jeff Kitt VAV proportioned to available airllow,v1d at 100%. Tested By: Jeff Kitt Test Date: April 10, 2009 Test Datav''''' „.„ .". 't )4 • ' IN • ,•••, Des. Fan/Heat CFM 200 CFM Act. Fan/Heat CFM 220 CFM Design Primary Max CFM 200 CFM Actual Max Primary CFM 220 CFM Design Primary Min. CFM 60 CFM Actual Primary Min. CFM 55 CFM 7 of 12 S' iii).Utili'' ,.. rte , ,,,,,,..,,...-„,....,,,,, • ee -4 ' ' ', '^'.... 1 .:f ., v,... , ....;,. ..,,,. '.;.;.-.,...-.. ,...:.,!,.;,", „ -- -. 01,-9--pi,Ty ',,', •:' ',. . Sfi ..., e . : . Lii W D,: '.•:':;"-.'..::: . r ''. ' ::S. ....,' C!M ' I. :,.. -' ' "--- 7 : . z. . . n. . , . SA-01 Lobby 101 LD 10 RD 310 300 96.77 SA-02 Lobby 101 LD 10 RD 310 305 98.39 . SA-03 Lobby 101 . LD - 10 RD 310 290 93.55 SA-04 Lobby 101 . LD 10 RD 270 295 109.26 SA-05 Lobby 101 LD 8 RD 210 190 90.48 . _ "..T) '..8. e ''',;" 4: :. .... -5 Unit ''. , , 1..... , ..' ‘ , 1 ' - ' . , ..,..0 ' '' ',... VAV Type VAV Address Box Inlet Size K Factor Series 22 12 RD 2.569 ,...,'' Test Data Fan Speed ADJ. (4) MAX. AIRTEST Co., Inc. Air Handling Unit Report PROJECT: Fidelity Investments - S. Seattle Branch LOCATION: Seattle, WA PROJECT #: 09-3005-1 SYSTEM/UNIT: Existing / FB-12 AREA: Operations 135 Existing / FB-12 Supply Outlet Summary * Notes Alitest Co Inc Preliminary Test and Balance Report DATE: 4/13/2009 CONTACT: Tested By: Jeff Kitt Test Date: April 08, 2009 -.1 ir,Test Data Des. Fan/Heat CFM 1400 CFM Act. Fan/Heat CFM 1380 CFM Design Primary Max CFM 1400 CFM Actual Max Primary CFM 1380 CFM Design Primary Min. CFM 420 CFM Actual Primary Min. CFM 435 CFM 8 of 12 s , f Motor Data l. s ; } ' ., Fan RPM Design Variable RPM External SP Design 0.35 in. wc SP In Actual N/A in. wc SP Out Actual N/A in. wc Motor Manufacturer QUEACE Motor HP 0.125 HP Motor RPM 1600 RPM Motor Frame 48Y Motor Rated Volts 115 Volts Motor Phase 1 Motor Hertz 60 Hz Motor FL Amps 1.7 Amps Motor Service Factor Not Listed Final Operating Hz 118 Hz Motor Amps 1 1.20 Amps °�i Fina1 ` . . d:, :F . EG Drive Type Direct Drive 150 ' ; r A ir Test Data��'r , the.%. Sv.f..h. `i'4 •i3' "�n r... . ... -.w'n C' a RR. Y fv/1 Womens 134 Total Fan CFM Des. 375 CFM Total Fan CFM Act. 383 CFM Tot. GRD CFM Des. 375 CFM Tot. GRD CFM Act. 383 CFM 8 RD i z, ' J A�� j , � " r t. � U mt Data ;F 4 ° � � Ly Unit Location Roof Unit Serves Restrooms Unit Manufacturer Cook Model Number 90 ACEH 90C15DH Serial Number 033SC37510-00/0000701 Fan Type / Class BI /1 °6WE �. r » � , t c� . f $f� d . �Tr ;#'fir ,A ' Ny •. a e st Data ,i�' �?,�st' r �. Fan RPM Design Variable RPM External SP Design 0.35 in. wc SP In Actual N/A in. wc SP Out Actual N/A in. wc a.� �,yy `tE ,, a ,, ,,st D � y lf �.�.d.t?v�.�t�rf'e.+ ni�iS'.� -�.. •.^�,Vdv..::iat_..�.. rt.+ � Rh .Ina Final Operating Hz 118 Hz Motor Amps 1 1.20 Amps ' System Unit ' t,4 = y rea Serv ¢ i s 2 . "x . � °t r a � e � O Type y a t Size LJW /,�1 ` 4g D 3 s ' D j ^ r 49,!!!1„. l t 4 a Fin a J ,x1_ Readmg . r °�i Fina1 ` EA -01 Mens 132 EG 8 RD 150 150 100 EA -02 Womens 134 EG 8 RD 150 160 107 EA -03 EG 8X8 75 73 97 �� °w � . .t�ix.>. 'Rl..� `�`.�,• ���� �. ����+ C • , ,�<,'>:T O ta I i n'�'`y��; - -... .,.8" -V D.. e m -t"`�.. . A,. �: �"j. :5. ���i�5 f' :. r�. T "e l r y �� r t' " S+375� t, - ''' .,o�bt'... ek :. ' .., `� . `� i .. �.�. sr 10%:' '� AIRIEST Co., Inc. Fan Unit Report PROJECT: Fidelity Investments - S. Seattle Branch LOCATION: Seattle, WA PROJECT #: 09- 3005 -1 SYSTEM /UNIT: EF 1XM AREA: Roof EF-1XM Exhaust Inlet Summary * Notes Airiest Co Inc DATE: 4/13/2009 CONTACT: Tested By: Jeff Kitt Test Date: April 10, 2009 Preliminary Test and Balance Report 9 of 12 4 .� Umt Da w + tids 8i R}$S .r. ,.. {u�_ 'c s Motor Data ` $� -' < � Y h Te st Data i r a y • r"c' * •:'tie � ' {i y,H^:�b u'a '. ... N�•Ni�"' Le � .3Y :'�t�5e� r,t 4 .'4' ' ", , ' ?a wt> .... ,.,,� 3�F} y sk,,aElettncalTest Da ta,q .:.L d.- ^vF;, a':.KN' A. '..-. i.w .. vim. ?w','V .• Motor Manufacturer QUEACE Motor HP 0.125 HP Motor RPM 1600 RPM Motor Frame 48Y Motor Rated Volts 115 Volts Motor Phase 1 Motor Hertz 60 Hz Motor FL Amps 1.7 Amps Motor Service Factor Not Listed ,% Final' , Deviation EA -01 ��rtt '-y" ae P vT:,, ; S ataak° Breakroom 130 EG Drive Type Direct Drive 280 275 yy A Y f M .Ai Test Data q- .1.. 4 l - . 'Y• 3 '.! t Cl ^?, ,� - A e. c';S r —. ,.(., .< ?v... xr4,. Total Fan CFM Des. 280 CFM Total Fan CFM Act. 275 CFM Tot GRD CFM Des. 280 CFM Tot. GRD CFM Act 275 CFM w F !� 1 ,S' .,:.A ,. T ` T �+i v. M . 4 .� Umt Da w + tids 8i R}$S .r. ,.. {u�_ Unit Location Roof Unit Serves Breakroom Unit Manufacturer Cook Model Number 90 ACEH 90C15DH Serial Number 033SC37510-00/0002001 Fan Type / Class BI/1 < � Y h Te st Data i r a y • r"c' * •:'tie � ' {i y,H^:�b u'a '. ... N�•Ni�"' Le � .3Y :'�t�5e� r,t Fan RPM Design Variable RPM External SP Design 0.35 in. wc SP In Actual N/A in. wc SP Out Actual N/A in. wc 4 .'4' ' ", , ' ?a wt> .... ,.,,� 3�F} y sk,,aElettncalTest Da ta,q .:.L d.- ^vF;, a':.KN' A. '..-. i.w .. vim. ?w','V .• Motor Volts 1 119 Volts Motor Amps 1 1.30 Amps ;System'/ Unit . , ? w 1.4 fArea'Served<�':~ , +c ' '.A -1 . .. "; t535 iOutlet Type l`P Sas LxW / gu. k n sD , x ! ! Design, ,r21). r2 Fi I r ' :, Readmg .', ,% Final' , Deviation EA -01 Breakroom 130 EG 12 RD 280 275 98 51 -; i ; '; ..,,- -w f - �' 'Y• 3 '.! t Cl ^?, ,� - A e. c';S r —. ,.(., .< ?v... xr4,. w F !� 1 ,S' .,:.A ,. T ` T �+i v. M . T t ., �' 'e y 28t1. Y' )" �ns.27 t R 3 C 98 ° �is^ ._.. AIRTEST Co., Inc. Fan Unit Report PROJECT: Fidelity Investments - S. Seattle Branch LOCATION: Seattle, WA PROJECT #: 09 3005 - 1 SYSTEM /UNIT: EF -2XM AREA: Roof EF-2XM Exhaust Inlet Summary * Notes Airiest Co Inc DATE: 4/13/2009 CONTACT: Tested By: Jeff Kitt Test Date: April 10, 2009 Preliminary Test and Balance Report 10 of 12 S it'p.f . , -c- ` Motor D-,.'vi-.....a...). ;E 4.ti spa ,., ' 3 Siz LxW / � "! i CFM r�Read m g : Motor Manufacturer QUEACE Motor HP 0.125 HP Motor RPM 1600 RPM Motor Frame 48Y Motor Rated Volts 115 Volts Motor Phase 1 Motor Hertz 60 Hz Motor FL Amps 1.7 Amps Motor Service Factor Not Listed estDat ., . a':.$ ...�'�: .. 5ril'. .. �.i1 % ■Final i atin s: .. o EA-01 y� '< r a heave: Data o r , ;{(? � ° .' f '' Electrical Test Data e: , R r°+r;, , k :e + :sY f t .�L .1, '!„, ,., .,, e.,sa a re ::.o,1.aN • .,w:. Drive Type Direct Drive .,. Motor Volts 1 119 Volts Motor Amps 1 1.60 Amps '; r. � t 5?y, ,4'dv ra. m . -• r 4 7�w i r rTe stData -4 :' •Y' <x ., ' ` ?4 ` t , .t?: ...-f Total Fan CFM Des. 425 CFM Total Fan CFM Act. 450 CFM Tot. GRD CFM Des. 425 CFM Tot. GRD CFM Act. 450 CFM pt 'fire, Unit Data�f } r� 4 , i 7' 3� ,v : ,., , v.p..,ty...k r - � '5..'s 4.ti spa ,., ' Unit Location Roof Unit Serves Elec Room Unit Manufacturer Cook Model Number 90 ACEH 90C15DH Serial Number 033SC37510 Fan Type / Class BI /1 Siz LxW / � "! i CFM r�Read m g : ' Design ? estDat ., . a':.$ ...�'�: .. 5ril'. .. �.i1 % ■Final i atin s: .. o EA-01 Fan RPM Design Variable RPM External SP Design 0.35 in. wc SP In Actual N/A in. wc SP Out Actual N/A in. wc EG 12 RD .' f '' Electrical Test Data e: , R r°+r;, , k :e + :sY f t .�L .1, '!„, ,., .,, e.,sa a re ::.o,1.aN • .,w:. .;.,,'� .,. Motor Volts 1 119 Volts Motor Amps 1 1.60 Amps r ou r d 'r y :Totals:. .° � .i;� s : a€ rh , j .,.r' .. a / Unit ab � ' , ¢ rea Served }z° ; .�5 Outlet Typei Siz LxW / � "! i CFM r�Read m g : ' Design ? ,� • % ■Final i atin s: .. o EA-01 Electrical 121 EG 12 RD 425 450 106 .P� A K`�F�'. ° .: " r ou r d 'r y :Totals:. .° � .i;� s : a€ rh , j .,.r' .. ri a t x ,. .. a.t - "425 x-$ s .i?: e,,.,.ra _ . ' ` ?4 ` t , .t?: ...-f l06% �a, ....,..a - ,s.,: AIRTEST Cam. Inc. Fan Unit Report PROJECT: Fidelity Investments - S. Seattle Branch LOCATION: Seattle, WA PROJECT #: 09- 3005 -1 SYSTEM /UNIT: EF-3XM AREA: Roof EF-3XM Exhaust Inlet Summa * Notes Airiest Co Inc DATE: 4/13/2009 CONTACT: Tested By: Jeff Kitt Test Date: April 10, 2009 Preliminary Test and Balance Report 11 of 12 4 Motor Data ...;i Motor Manufacturer N/L Motor HP N/L HP Motor RPM N/L RPM Motor Frame N/L Motor Rated Volts 277 Volts Motor Phase 1 Motor Hertz 60 Hz Motor FL Amps 0.25 Amps Motor Service Factor N/L Unit Location Unit Serves Unit Manufacturer Model Number Serial Number Utility RM 113 Utility RM 113 G-Mark MUH0371 4104-0275-038 Data .. .„, , „ t.,1!:', .;-, . ... L • , — , 1 .•,',,- i:. , — , 0 -.'• ., . , ' V •-• ' ,,c?.s.,, ,,,..... ,• -4' -...1: Data ,-- .: ,,, .''' , 't " ' Test a . ,,t . ' '',. '''... Drive Type Direct Drive ;'.' 2 ■•',.:" . 1 ? Fan RPM Design SP In Actual SP Out Actual Ali Test biiL ,*r, 3',: ..: ' i'' r. '1:,st , . ■•■ ,. . , x. ':, ji... ''` : .., • .., .:' '—' Total Fan CFM Des. 350 CFM Tot. GRD CFM Des. 350 CFM AIRTEST Co., Inc. Fan Unit Report PROJECT: Fidelity Investments - S. Seattle Branch LOCATION: Seattle, WA PROJECT #: 09-3005-1 SYSTEM/UNIT: UH-1 AREA: Utility RM 113 * Notes Airiest Co Inc DATE: 4/13/2009 CONTACT: Tested By: Jeff Kitt Test Date: April 10, 2009 Preliminary Test and Balance Report 12 of 12 ...;i _.. Unit Location Unit Serves Unit Manufacturer Model Number Serial Number Utility RM 113 Utility RM 113 G-Mark MUH0371 4104-0275-038 i:. , — , 0 -.'• ., . , ' V •-• ' ,,c?.s.,, ,,,..... ,• -4' -...1: Data ,-- .: ,,, .''' , 't " ' Test a . ,,t . ' '',. '''... /,' ;'.' 2 ■•',.:" . 1 ? Fan RPM Design SP In Actual SP Out Actual N/L RPM N/A in. wc N/A in. wc AIRTEST Co., Inc. Fan Unit Report PROJECT: Fidelity Investments - S. Seattle Branch LOCATION: Seattle, WA PROJECT #: 09-3005-1 SYSTEM/UNIT: UH-1 AREA: Utility RM 113 * Notes Airiest Co Inc DATE: 4/13/2009 CONTACT: Tested By: Jeff Kitt Test Date: April 10, 2009 Preliminary Test and Balance Report 12 of 12 ACTIVITY NUMBER: M08 -240 DATE: 09 -30 -08 PROJECT NAME: FIDELITY INVESTOR CENTER SITE ADDRESS: 304 STRANDER BL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Building Div ision Complete Comments: � PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Public Works ❑ Structural 671 1/L ik 10 -1 Fire Prevention Incomplete Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10-02-08 Not Applicable n IJ.! INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Permit Cerifer'. -Use'O i4' Please Route Documents/routing slip.doc 2 -28-02 TUESITHURS ROUTING: Structural Review Required ❑ No further Review Required n REVIEWER'S INITIALS: DATE: DUE DATE: 10-30-08 Approved ❑ Approved with Conditions i Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Permit'Center'use "Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 AMERICAN CONTRACTORS INDEM CO 100018683 02/17/2007 Until Cancelled $12,000.00 02/26/2007 1 ACCREDITED SURETY Et CAS CO 10034059 06/27/2005 Until Cancelled 02/17/2007 $12,000.0006/28 /2005 Name Role Effective Date Expiration Date OKITSU, RODNEY STERLING AGENT 06/28/2005 Amount OKITSU, RODNEY STERLING PRESIDENT 06/28/2005 CPP1002918 Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 5 WESTERN NATIONAL ASSUR CO CPP1002918 10/13/200810/13 /2009 $1,000,000.0010 /13/2008 4 OHIO CAS INS CO BL053526359 08/13/200708/13 /2009 $1,000,000.0008 /11/2008 Untitled Page Page 1 of 2 General /Specialty Contractor A business registered as a construction contractor with LEtI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company OKITSU CONSTRUCTION INC 2067149969 1428 WHITWORTH AVE S RENTON WA 98055 KING CORPORATION UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 602515973 ACTIVE OKITSCI959L8 CONSTRUCTION CONTRACTOR 6/28/2005 6/28/2009 OKITSC*030R3 GENERAL UNUSED Business Owner Information Bond Information Insurance Information https: / /fortress.wa. gov /lni/bbip /Detail. aspx ?License = OKITS CI959L8 01/23/2009 DUCTWORK SINGLE LINE DOUBLE LINE SINGLE LINE DOUBLE LINE RECTANGULAR W D WxD SUPPLY DUCT RECTANGULAR W D WxD RETURN /EXHAUST DUCT W= WIDTH, D= DEPTH A W= WIDTH, D =DEPTH 10x6 10x6 ; ; (INCHES UNLESS NOTED - OTHERWISE) AS VIEWED DIA "0 DIA (INCHES UNLESS NOTED OTHERWISE) AS VIEWED DIA" 0 DIA ROUND SUPPLY DUCT ,. ` _ r ROUND RETURN EXHAUST , 1 0 o S ' ' (DIA = INSIDE DIAMETER) 1 ) DUCT (DIA = INSIDE DIAMETER) ' F RETURN /EXHAUST DUCT UP -..----Z1 SUPPLY DUCT UP HORIZONTAL OFFSET STANDARD RADIUS ELBOW (R = W) > �'�"� SUPPLY /RETURN /EXHAUST SUPPLY /RETURN /EXHAUST R I -W- I TAP TAKE 45' -OFF 45' TAKEOFF 45' TAKE -OFF TRANSITION TO ROUND RECTANGULAR WYE SUPPLY "^ 0,11 MIN Off 10x6 RECTANGULAR DUCT 6 ' TAKE -OFF 5 TO ROUND ' " S 6"o' 10x6 SQUARE BELLMOUTH TO ROUND CONNECTION CONNECTION SUPPLY /RETURN/ EXHAUST TAKE -OFF TO DIFFUSER /GRILLE HARD = CONVERGE 5 I RETURN /EXHAUST -� la ELBOW S , W/45' TAKE --OFFS U SUPPLY CEILING " LINEAR DIFFUSER FLEXIBLE DUCT (W /SHEETMETAL PLENUM, LINING & FOR BRANCH CONN. h --,� OPEN END DUCT I ^` EVERY 4' OF LINEAR.) 1 PLENUM BY LD MF'R ` 1N/ 1/2 "x1/2" WMS SP STATIC PRESSURE SENSOR "-__I I VD MANUAL VOLUME DAMPER SD DUCT MOUNTED SMOKE DETECTOR BACKDRAFT DAMPER — • BDD STANDARD 4 -WAY BLOW SUPPLY DIFFUSER 3 -WAY BLOW SUPPLY DIFFUSER OR 4 2 -WAY BLOW SUPPLY DIFFUSER C ONE -WAY BLOW SUPPLY DIFFUSER RETURN /EXHAUST GRILLE OR REGISTER r- -I TYPICAL SUPPLY LINEAR DIFFUSER UC 1/2" UNDERCUT DOOR - *J RETURN OR EXHAUST AIR FLOW —.- SUPPLY AIR FLOW South Seattle Branch 304 Strander Blvd, Seattle, WA 98188 Gensler A Issue -- 01 ENGINEERS Project Name 02006 Gensler Date & Issue Description By Check 07/02/08 KJL TPW ISSUED FOR CONSTRUCTION Richard D. Kimball Company, Inc Seaport Center 70 Fargo Street Suite 801 Boston, MA 02210 -1964 T 617-345 -9885 F 617 -345 -4226 W www.rdkengineers.cam 20080075 1 CAD File Name 20080075J-101.01 Description HVAC LEGEND, NOTES AND ABBREVIATIONS 133 Federal Street 5th Floor Boston MA 02110 Telephone 617.292.4400 Facsimile 617.292.4401 Fidelity Investor Center — SEATTLE BRANCH ABBREVIATIONS ENERAL AD ADD'L AFF ALT AMP AP ARCH ATC AVE BHP BI BTU BTU H CENT CF CFM CLG CO CONN CONTR D DB DEG DIA DIM DN DWG EA EAT ELEC ELEV ENT ESP EXH EXIST. EXT F FLA FLEX FPM FT GA GAL GALV GC GPM GYP HORIZ HP HR HTC HZ IN ISOL KW L LAT LB LF LRA MAX MBH MCA MECH MF'R MIN N/A NC NO NO. NTS ACCESS DOOR ADDITIONAL ABOVE FINISHED FLOOR ALTITUDE OR ALTERNATE AMPERE ACCESS PANEL ARCHITECT AUTOMATIC TEMPERATURE CONTROL AVERAGE BREAK HORSE POWER BACKWARDS INCLINE BRITISH THERMAL UNIT BTU PER HOUR CENTRIFUGAL CUBIC FEET CUBIC FEET PER MINUTE CEILING OR COOLING CARBON MONOXIDE CONNECTION CONTRACTOR DRAIN OR DEPTH DRY BULB TEMPERATURE DEGREE DIAMETER DIMENSION DOWN DRAWING EACH OR EXHAUST AIR ENTERING AIR TEMPERATURE ELECTRICAL ELEVATION ENTER EXTERNAL STATIC PRESSURE EXHAUST EXISTING EXTERNAL FAHRENHEIT FULL LOAD AMPS FLEXIBLE FEET PER MINUTE FEET GAUGE GALLONS GALVANIZED GENERAL CONTRACTOR GALLONS PER MINUTE GYPSUM HORIZONTAL HORSEPOWER OR HIGH POINT HOUR HEATING HERTZ (FREQUENCY, CYCLES PER SECOND) INCHES ISOLATION KILOWATT LENGTH LEAVING AIR TEMPERATURE POUND LINEAR FEET LOCKED ROTOR AMPS MAXIMUM THOUSAND BTUH MINIMUM CIRCUIT AMPS MECHANICAL MANUFACTURER MINIMUM NOT APPLICABLE NORMALLY CLOSED OR NOISE CRITERIA NORMALLY OPEN NUMBER NOT TO SCALE OA OUTSIDE AIR OPD OVER CURRENT PROTECTION DEVICE PD PRESSURE DROP PH PHASE POS PROVIDED BY OTHER SECTION PRESS PRESSURE PSI POUNDS PER SQUARE INCH PVC POLYVINYL CHLORIDE QTY QUANTITY R RADIUS RA RETURN AIR REQ'D REQUIRED RLA RUNNING LOAD AMPS RM ROOM RPM REVOLUTIONS PER MINUTE SAT SCH SDET SEN SF SP SPECS SQ SS SUP T TA TEMP TSTAT TON TYP UC V W W/ WB WC WG W/O WSA XM DUCT ACD BDD DI FF EA LD OA QED RA SA TA VD VAV WMS ECU H EF FB RTU UH VFD SATURATED AIR TEMPERATURE SCHEDULE SMOKE DETECTOR SENSIBLE SQUARE FEET STATIC PRESSURE SPECIFICATIONS SQUARE STAINLESS STEEL SUPPLY TEMPERATURE THROW AWAY TEMPERATURE THERMOSTAT 12,000 BTUH COOLING CAPACITY TYPICAL UNDERCUT DOOR VOLTS (ELECTRICAL) WIDTH OR WATT WITH WET BULB WATER COLUMN WATER GAUGE WITHOUT WIRE SIZE AMP EXISTING EQUIPMENT TO REMAIN AUTOMATIC CONTROL DAMPER BACKDRAFT DAMPER DIFFUSER EXHAUST AIR LINEAR DIFFUSER OUTSIDE AIR OPEN END DUCT RETURN AIR SUPPLY AIR THROW AWAY OR TRANSFER AIR VOLUME DAMPER VARIABLE AIR VOLUME SUPPLY AIR TERMINAL WIRE MESH SCREEN EQUIPMENT ACCU AIR COOLED CONDENSING UNIT CRAC COMPUTER ROOM AIR CONDITIONING UNIT DX DIRECT EXPANSION ELECTRIC CABINET UNIT HEATER EXHAUST FAN FAN BOX ROOF TOP UNIT UNIT HEATER VARIABLE FREQUENCY DRIVE PIPING CO CLEAN OUT M: \2006 \20080075— Fidelity Seattle, WA \Hvoc \20080075 HO1.01 HVAC LEGEND, NOTES & ABBREVIAfIONS.dwg [30x42] September 23, 2008 — 4:05pm cbutts DIAGRAM EQUIPMENT SYMBOLS r L L ROOFTOP UNIT ELECTRIC CABINET UNIT HEATER (DUCTED) COMPUTER ROOM AIR CONDITIONING UNIT ROOF MOUNTED AIR COOLED CONDENSER UNIT ROOF MOUNTED EXHAUST FAN FAN POWERED BOX W /ELEC HEAT VERTICAL UNIT HEATER CALLOUT SYMBOLS 0 O 0 SA(100) - RA(100) EA(100) CONNECT NEW TO EXISTING REVISION NUMBER TEMPERATURE SENSOR OR THERMOSTAT CARBON DIOXIDE SENSOR EQUIPMENT REQUIRING ELECTRICAL SERVICE, SEE SCHEDULE FOR PERFORMANCE REQUIREMENTS: S = SUPPLY A = SCHEDULED DIFFUSER. (100) = CFM TO BALANCE TO R = RETURN A = SCHEDULED GRILLE. (100) = CFM TO BALANCED TO E = EXHAUST A = SCHEDULED REGISTER /GRILLE (100) = CFM TO BALANCED TO SCHEDULED EQUIPMENT UNIT NUMBER TAG UNIT CAPACITY INFORMATION: DATA }- — CFM , TONS, GPM ETC, SEE SCHEDULE FOR PERFORMANCE REQUIREMENTS CONTROL POINT DESCRIPTOR LEGEND TAG ELEC ATC CONTRACTOR PROVIDED DDC POINT AND HARDWARE CONTROL DEVICE FURNISHED BY ELECTRICAL OR PLUMBING CONTRACTOR BUT INTERFACED TO DDC SYSTEM BY ATC CONTRACTOR ATC CONTRACTOR INTERFACE TO EQUIPMENT MANUFACTURER'S HARDWARE CONTROL ABBREVIATIONS AFM ASC ATC AIR FLOW MEASURING STATION APPLICATION SPECIFIC CONTROLLER AUTOMATIC TEMPERATURE CONTROL BDD BACKDRAFT DAMPER (ADJUSTABLE COUNTERWEIGHT) C CARBON DIOXIDE SENSOR CT CURRENT TRANSFORMER (STATUS FEEDBACK) DAT DISCHARGE AIR TEMPERATURE SENSOR DDC DIRECT DIGITAL CONTROL DSP DISCHARGE STATIC PRESSURE SENSOR EAD HOA LAT NC NO OAD OAE PAD RAD SAD SDET SP S/S T TR VFD EXHAUST AIR DAMPER HANDS -OFF AUTOMATIC SWITCH LEAVING AIR TEMPERATURE NORMALLY CLOSED (ON LOSS OF POWER) NORMALLY OPEN (ON LOSS OF POWER) OUTSIDE AIR DAMPER OUTSIDE AIR HUMIDITY SENSOR (FOR WET BULB READING) PRIMARY AIR DAMPER RETURN AIR DAMPER SUPPLY AIR DAMPER SMOKE DETECTOR STATIC PRESSURE SENSOR START /STOP TEMPERATURE SENSOR /THERMOSTAT TEMPERATURE SENSOR /THERMOSTAT (ROOM) VARIABLE FREQUENCY DRIVE SPEED REVOI E.15t6C- CODE PPR OVED OC1 1 2008 i FELE C Permit No. SEPARATE PERMIT REQUIRED FOR: a Mechanical (fEiectrical gelumbing as Piping City of Tukwila BUILDING DIVISION Plar review approval is subject to errors and omissions Approval of construction documents does not aulhorizE the violation of any adopted code or ordinance. Receip of approved Field C F an, c r +l cons is acknowledge( By Date: 0 City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. RECEIVED SEP 3 2110 PERMIT CENTER MO9 v+o II II II II SB(175 SB(175) 14x12 SB(175) SB(1 75) 24x16 14x10 SA(115) 20x12 20x12 SA(1 15) SA(1 15) SB(150) SA(30) Q SF(75) — 4' -0" 14x14 DUCT UP TO EF -1XM (375) EB(150) 50(450) 14x14 DUCT UP TO EF -2XM (280 SA(50) SC(1250) 30x12 36x16 EB(150) — rl 22x12 28x18 RA UP TO RTU -2XM 12x12 10x12 14x14 DUCT UP TO EF -3XM (425) j 16x14 CRAC -1XM 10x8 SA(75) SB(125) 8x18 RA UP RTU-1XM 10x10 RS. L UP THROUGH ROOF TO ACCU -1XM 24x21 SA UP TO RTU -2XM (4535) n 30x12 SA(95) - -20x12 4.OkW SB(185) 20x12 SB(125) ® RA( —) 12x10 14x10 SB EA(425) 10x10 SB(160) 14x14 0 SE(280) 7' -9" 7' -9" Q SE(280) 0 SE(280) 7' -9" 0 SE(280) 8' -6" 0 SE(280) 18' -3 "L ao SE(280) SE(280) M: \2008 \20080075— Fidelity Seattle, WA \Hvec \20080075 H02.01 HVAC PLAN 1ST FLR.dwg [30x42] September 23, 2008 — 4:05prn cbutts SE(280) SE(280) LF- SE(280) 3kW 10 "0 23' -3" 0 4' —O" RC( —) 8x8 J J 8x8 3kW r SG(250) SE(310) SE (310) r RA( —) SE(310) E —6"93 SB(130) J RA(—) 1 =f ( 4' -0" 28' —0" 0 3' -6" SE(210) 11'-3" SE(270) KEY NOTES O PROVIDE INSULATED BACK PLATE FOR PERIMETER MOUNTED T —STAT. 0 RUN 3/4" CONDENSATE DRAIN LINE TO SLOP SINK IN JANITOR'S CLOSET. • PROVIDE REMOTE BALANCING VOLUME DAMPER. REFER TO DETAIL HSM004 ON DRAWING H07.01. O CONTRACTOR TO PROVIDE EQUIVALENT OF 24 SQUARE INCH OF OPENING FOR HEAT TRANSFER OF AV EQUIPMENT TO CEILING PLENUM. PROVIDE 3' —O" INSULATED PLENUM BOX. • PROVIDE 2' —O" INSULATED PLENUM BOX. O SENSOR IS MOUNTED IN LINEAR RETURN GRILLE AND SHALL BE WIRED TO THE UNIT MOUNTED T —STAT, 0 PROVIDE ACCESS PANEL FOR ECUH -1. COORDINATE EXACT SIZE AND LOCATION WITH ARCHITECT & MANUFACTURER. O PROVIDE RETURN AIR BOOT. REFER TO DETAIL HSMO22 ON DWG H07.01. • CONNECT EXHAUST FAN TO LIGHTING CONTROL PANEL. REFER TO DWG H06.01 FOR CONTROL DIAGRAM. 11 BALANCE EXISTING EXHAUST FANS TO CONNECTED CFM AS SHOWN. Q CONNECT EXHAUST FAN TO NEW T —STAT AS SHOWN. REFER TO DWG H06.01 FOR CONTROL DIAGRAM. • CONFIRM FINAL LOCATION OF WALL MOUNTED CONTROLLER FOR ROOFTOP UNITS AND VAVS. O PROVIDE 4 -0" INSULATED PLENUM BOX. SHEET NOTES REVIEW FOK CODE COMPLIANCE APPROVED OCT 0 9 2008 City Of Tukwila B ILA ©Nip 1. REFER TO DRAWING H01.01 FOR LEGEND AND ABBREVIATIONS. 2. REFER TO DRAWING H09.01 FOR SPECIFICATIONS AND NOTES. 3. RTU -1 AND 2, ACCU -1, AND CRAC -1 ARE PROVIDED UNDER BASE BUILDING CONTRACT. CONTRACTOR TO CONNECT DUCTWORK /PIPING AS SHOWN. 4. CONTRACTOR SHALL FIELD CONFIRM ALL LINEAR DIFFUSER LENGTHS WITH ARCHITECT PRIOR TO INSTALLATION. 5, TAKE —OFFS TO DIFFUSERS SHALL BE SIZED TO MATCH DIFFUSER NECK SIZE UNLESS OTHERWISE NOTED. REFER TO DETAIL HSMO21 ON DRAWING H07.01. 6. PRIMARY AIR TAKE —OFFS TO FAN POWERED BOXES SHALL BE SIZED TO EQUAL PRIMARY AIR INLET SIZE. IF LENGTH OF DUCT TAKE —OFF EXCEEDS 10 FEET THEN REFER TO DETAIL HSM002 ON SHEET H07.01. 6. ACOUSTICAL SOUND LINING: MATERIALS AND INSTALLATION SHALL MEET THE FOLLOWING STANDARDS, AS APPLICABLE: NFPA -90A, UL723, NFPA -255; SMACNA DUCT LINER APPLICATIONS STANDARD; SMACNA MECHANICAL FASTENERS STANDARD; ADHESIVE AND SEE LANT COUNCIL: ADHESIVES STANDARD FOR DUCT LINER — ASC— A- 7001A; ASTM E -84 FIRE HAZARD CLASSIFICATIONS OF 25 FLAME SPREAD, 50 SMOKE DEVELOPED, AND 50 FUEL CONTRIBUTED. INTERNAL AIRFLOW DIMENSIONS ARE SHOWN FOR DUCTS, CONTRACTOR SHALL INCREASE DUCT SIZE FOR LINING. PROVIDE MINIMUM 1" THICK ACOUSTICAL LINING. TO MEET THE ENERGY CODE REQUIREMENTS FOR R5 INSULATION FOR SUPPLY AND RETURN DUCTWORK IN PLENUMS, PROVIDE EITHER 1 -1/2" THICK LINING OR 1" THICK LINING WITH MINIMUM 1/2" THICK EXTERIOR INSULL.4TION. SEAL ALL JOINTS WITH MANUFACTURER APPROVED MASTIC. USE SHEET METAL NOSING AT ALL RAW EDGES, LINING SHALL BE BY CERTAIN —TEED, KNAUF, OWENS CORNING, OR MANVILLE FOR THE FOLLOWING DUCTWORK: 1) SUPPLY, RETURN, AND EXHAUST AIR DUCTWORK, INCLUDING PLENUMS, FOR MINIMUM OF 20 FEET FROM ROOFTOP UNITS AND EXHAUST FANS, 2) ALL LOW PRESSURE DUCTWORK DOWNSTREAM OF FAN BOXES, 3) TRANSFER DUCTS. 7. DUCT INSULATION (EXTERNAL): INSULATION SHALL BE CERTAIN —TEED, KNAUF, MANVILLE, OR OWENS CORNING. MATERIALS SHALL MEET REQUIREMENTS OF ADHESIVE AND SEALANT COUNCIL STANDARDS AND SMACNA. DUCTWORK THAT IS LINED DOES NOT NEED EXTERNAL INSULATION EXCEPT FOR SUPPLY AND RETURN DUCTWORK LINED WITH ONLY 1" THICK LINING LOCATED IN PLENUMS. TO MEET THE ENERGY CODE R5 REQUIREMENT, ADD A MINIMUM 1/2" THICK EXTERIOR INSULATION TO THESE LINED DUCTS. INSULATE ALL SUPPLY AIR DUCTS AND PLENUMS. EXPOSED INSULATION SHALL BE RIGID FIBERGLASS INSULATION WITH ALUMINUM VAPOR BARRIER. t1O82LmIO FldeIily I IV VE TMENTS South Seattle Branch 304 Strander Blvd. Seattle, WA 98188 Gensler ENGINEERS IA Issue 01 Seal /Signature Project Name Fidelity Investor Center — SEATTLE BRANCH Project Number 20080075 CAD File Name 200800753-102.01 Description HVAC PLAN FIRST FLOOR 1Scale 1/4 "= 1 * -0• 01' 2' 4 8 H02.01 Q2006 Gensler 133 Federal Street 5th Floor Boston MA 02110 Telephone 617.292.4400 Facsimile 617.292.4401 Richard D. Kimball Company, Inc Seaport Center 70 Fargo Street Suite 801 Boston, MA 02210 -1964 T 617- 345 -9885 F 617 -345 -4226 W www.rdkengineers.com Date & Issue Description By 07/02/08 KJL ISSUED FOR CONSTRUCTION RECEWED SEP 3 2009 PERMIT CENTER Check TRW ECUH -1 RA FROM RM SA TO ROOM VESTIBU CEILING MOUNTED EL CTRIC CABINET UNIT HEATER: GENERAL 1. THE FAN AND ELECTRIC HEATING COIL SHALL BE CONTROLLED BY T -STAT MOUNTED IN RETURN GRILLE. CONTROL SEQUENCE 1. WHEN THE SENSOR LOCATED IN THE ASSOCIATED RETURN GRILLE SENSES A DROP IN SPACE TEMPERATURE BELOW SETPOINT (72T ADJ) THE FAN SHALL ENERGIZE AND THE ELECTRIC COIL SHALL STAGE ON /OFF AS REQUIRED UNTIL SENSOR IS SATISFIED FOR A PERIOD OF 5 MINUTES. m CEILING MOUNTED ECUH CONTROL SEQUENCE UH -1 T ) TO ROOM MECHANICAL ROOM CEILING MOUNTED ELECTRIC CABINET UNIT HEATER: GENERAL 1. THE FAN AND ELECTRIC HEATING COIL SHALL BE CONTROLLED BY A UNIT MOUNTED T -STAT. CONTROL SEQUENCE 1. WHEN THE UNIT MOUNTED T -STAT SENSES A DROP IN SPACE TEMPERATURE BELOW SETPOINT (50'F ADJ) THE FAN SHALL ENERGIZE AND THE ELECTRIC COIL SHALL STAGE ON /OFF AS REQUIRED UNTIL SENSOR IS SATISFIED FOR A PERIOD OF 5 MINUTES. 2. PROVIDE ALL SAFETIES AND INTEGRAL COMPONENTS NECESSARY IN ORDER TO COMPLETE THIS SEQUENCE OF OPERATION. D VERTICAL MOUNTED UH CONTROL SEQUENCE M: \2008\20080075- Fidelity Seattle, WA \Hvac \20080075 H06 01 HVAC CONTROL DIAGRAM.dwa [30x42] Septernber 23, 2008 - 4:05pm cbutts CRAC CONTROL SEQUENCE. A. GENERAL C. ALARMS FROM LAN RM TO LAN RM ACCU -XM ON ROOF 1. CRAC SHALL BE CONTROLLED, ON AN INDIVIDUAL BASIS BY A MANUFACTURER SUPPLIED PACKAGE CONTROL UNIT 2. THIS SEQUENCE APPLIES TO CRAC =XM. 3. UNIT SETPOINT SHALL BE ADJUSTABLE BY THE UNIT CONTROLLER. 4. ALL UNIT ALARMS SHALL BE DISPLAYED LOCALLY AND SPECIFIC ALARMS SHALL BE TRANSMITTED TO A MANUFACTURER SUPPLIED REMOTE MONITORING PANEL LOCATED IN THE LAN ROOM. B. INDIVIDUAL CRAC CONTROL 1. SPACE TEMPERATURE a. LOCAL TEMPERATURE SHALL BE SENSED BY THE UNIT'S RETURN AIR TEMPERATURE SENSOR. b. WHEN LOCAL TEMPERATURE RISES ABOVE THE SETPOINT OF 72'F(ADJUSTABLE) THE ROOF MOUNTED CONDENSING UNIT SHALL ENERGIZE. c. THE CRAC FAN SHALL RUN CONTINUOUSLY 24/7. a. ALARMS SHALL BE GENERATED BY THE FOLLOWING CONDITIONS. I. RETURN AIR TEMPERATURE ABOVE 80'F FOR LONGER THEN 5 MINUTES(ADJUSTABLE). ii. RETURN AIR TEMPERATURE BELOW 60'F FOR LONGER THEN 5 MINUTES.(ADJUSTABLE). iii LEAK DETECTOR ACTIVATION. D. OFF SITE MONITORING. THE ALARM PANEL SHALL HAVE A MODEM CONNECTION CAPABLE OF SENDING ALARM SIGNALS, VIA A INTERNET CONNECTION, TO AN OFF SITE MONITORING STATION. CRAC -XM CONTROL SEQUENCES EXHAUST FANS: GENERAL 1. THE EXHAUST FANS EF- 1XM,2XM SHALL BE RUN CONTINUOUSLY DURING BUILDING OCCUPIED HOURS. FAN CONTROL 1. THE FAN SHALL BE ACTIVATED VIA THE LIGHTING CONTROL PANEL. UPON ACTIVATION THE EXHAUST AIR DAMPER(EAD) SHALL OPEN AND THE FAN ENABLED. EXHAUST EXHAUST FAN CONTROL EF -1 XM,2XM BDD EXHAUST FANS: GENERAL FAN CONTROL EXHAUST BDD EF -3XM 1. THE EXHAUST FAN EF -3XM SHALL BE CONTROLLED VIA REVERSE ACTING SPACE MOUNTED THERMOSTAT. 1. THE FAN SHALL ACTIVATED WHEN SPACE THERMOSTAT SENSES A RISE IN TEMPERATURE ABOVE 85'F (ADJ). WHEN THE T -STAT IS SATISFIED FOR A PERIOD OF FIVE MINUTES THE FAN SHALL DEACTIVATE. D 0 EXHAUST FAN CONTROL GENERAL FAN CONTROL OCCUPIED HEATING CONTRQL OCCUPIED COOLING CONTROL UNOCCUPIED HEATING CONTROL UNOCCUPIED COOLING CONTROL 1. THERE SHALL BE NO UNOCCUPIED COOLING. UNOCCUPIED OVERRIDE D PRIMARY AIR SERIES FAN POWERED BOX WITH ELECTRIC HEATING CONTROL SEQUENCES SUPPLY AIR 1. FAN POWERED BOX SHALL BE CONTROLLED BY AN APPLICATION SPECIFIC CONTROLLER (ASC). COORDINATE OCCUPIED /UNOCCUPIED SCHEDULES WITH OWNER. ALL SETPOINTS SHALL BE ADJUSTABLE. ALL ACTUATORS SHALL BE ELECTRONIC. 2. ALL TEMPERATURES LISTED ARE FAHRENHEIT AND SHALL BE ADJUSTABLE. 3. OCCUPIED HEATING SETPOINT SHALL BE 69'F. OCCUPIED COOLING SETPOINT SHALL BE 5'F WARMER THAN HEATING SETPOINT. 4. ROOM TEMPERATURES SHALL BE SET BY A WALL MOUNTED ADJUSTABLE T -STAT. 5. MAXIMUM PRIMARY AIRFLOW IS SHOWN ON PLANS. MINIMUM PRIMARY AIRFLOW SHALL BE 30% OR AS SHOWN ON DRAWINGS 6. PROVIDE WALL - MOUNTED CONTROLLER BY RTU MANUFACTURER TO INTERLOCK FAN BOXES WITH ROOFTOP UNIT. 1. WHILE IN UNOCCUPIED MODE, FAN SHALL BE OFF WITH THE PRIMARY AIR DAMPER (PAD) CLOSED AND THE ELECTRIC HEATING COIL (EHC) OFF. 2. WHEN BOX IS STARTED IN OCCUPIED MODE, THE PAD SHALL OPEN TO MINIMUM AIRFLOW AND THE FAN SHALL START AND RUN CONTINUOUSLY. 1. UPON A CALL FOR HEATING FROM THE ROOM TEMPERATURE SENSOR (TR), THE PAD SHALL MODULATE TO ITS MINIMUM AIRFLOW AND THE EHC SHALL BE ENERGIZED IN STAGES AS REQUIRED TO MAINTAIN THE HEATING SETPOINT. THE REVERSE SHALL OCCUR ON A RISE IN SPACE TEMPERATURE. 1. UPON A CALL FOR COOLING FROM THE ROOM TEMPERATURE SENSOR (TR), THE PAD SHALL MODULATE BETWEEN MINIMUM AND MAXIMUM AIR FLOWS AS REQUIRED TO MAINTAIN THE COOLING SETPOINT WITH THE EHC OFF, MORNING WARM -UP. 1. FAN BOXES HAVE EITHER A TEMPERATURE SENSOR OR HARDWIRE TO RTU TO SIGNAL PAD TO OPEN 100% DURING MORNING WARM UP. REFER TO RTU SEQUENCES. 1. IF, WHEN THE UNIT IS OFF, THE ROOM TEMPERATURE FALLS BELOW 56'F, THE FB FAN SHALL START WITH THE PAD CLOSED AND EHC SHALL BE STAGED TO MAINTAIN A DISCHARGE AIR TEMPERATURE (DAT) BETWEEN 85 AND 90'F (ADJ). WHEN ROOM TEMPERATURE RISES ABOVE 60'F, THE EHC SHALL CYCLE OFF AND, AFTER A 1- MINUTE DELAY, THE FAN SHALL STOP. 1. BUTTON ON TR SHALL ALLOW 2 -HOUR (ADJ) OVERRIDE FROM UNOCCUPIED TO OCCUPIED CONTROL. WHEN ANY ROOM IS IN THIS OVERRIDE, THE CONTROL SYSTEM SHALL ENSURE THAT ENOUGH "UNOCCUPIED" ZONES ARE ALSO OVERRIDDEN SO THAT THE ASSOCIATED AIR HANDLER CAN OPERATE AT MINIMUM AIR FLOW IN THIS MODE. SAFETIES 1. WHEN THE ASSOCIATED RTU UNIT SMOKE DETECTOR IS ACTIVATED THE FAN BOX SHALL BE COMMANDED OFF. 2. PROVIDE ALL NECESSARY COMPONENTS, WIRING, SOFTWARE, PROGRAMMING, TO MAKE INTERLOCK WITH RTU AND COMPLETE ALL SEQUENCES NOTED. SERIES FAN POWERED BOX WITH ELECTRIC HEATING CONTROL SEQUENCES ROOF TOP UNIT CONTROLS: GENERAL FAN CONTROL RELIEF AIR OUTDOOR io AIR BDD (ADJUSTABLE) 1. ROOFTOP UNIT SHALL BE STARTED AND STOPPED VIA DEDICATED MICROPROCESSOR CONTROLLER, WALL MOUNTED IN SPACE. COORDINATE OCCUPIED/ UNOCCUPIED SCHEDULES WITH OWNER. ALL SETPOINTS SHALL BE ADJUSTABLE. 2. LOCAL HAND -OFF- AUTOMATIC SWITCH (H -O -A) FOR FANS SHALL OVERRIDE CONTROLLER START /STOP (S /S) COMMANDS. ALL HARDWIRED SAFETIES SHALL BE ACTIVE IN BOTH "H" AND "A" POSITIONS. ■ If 3. ALL TEMPERATURES LISTED ARE FAHRENHEIT. 4. PROVIDE APPROPRIATE ANTI- RECYCLE TIME DELAYS ON COMPRESSOR. 5. MINIMUM OUTSIDE AIR SHALL BE 780 CFM FOR RTU -1XM AND 540 CFM FOR RTU -2XM. 1. WHILE IN THE OFF MODE (OR ON SAFETY OR MANUAL DISCONNECT) RTU SUPPLY FAN SHALL BE OFF WITH THE OUTSIDE AIR DAMPER (OAD) AND POWERED EXHAUST DAMPER CLOSED, THE CONDENSING UNIT AND GAS HEATER OFF, AND THE RETURN AIR DAMPER (RAD) OPEN. 2. WHEN STARTED IN OCCUPIED MODE, THE RTU FAN SHALL START IN RECIRCULATION MODE (100% RETURN AIR) AT MINIMUM SPEED. 3. THE FAN VFD SHALL SLOWLY INCREASE IN SPEED TO MAINTAIN SETPOINT OF REMOTE DIFFERENTIAL PRESSURE SENSOR (DPS). INITIAL SETPOINT SHALL BE 1.25" W.G. WITH FINAL SETPOINT DETERMINED BY THE BALANCING CONTRACTOR TO BE AS LOW AS NEEDED TO PROVIDE FULL AIRFLOW TO THE MOST REMOTE TERMINAL BOXES WITH THEIR PRIMARY AIR DAMPERS AT LEAST 95% OPEN. 4. AFTER STARTUP, ONCE FAN OPERATION IS STABLE, THE OAD AND THE RAD SHALL SLOWLY OPEN TO MINIMUM OUTDOOR AIR POSITION. ©Dd ✓ /ii,ruD I NO ..s .ir rr. . ! ] RETURN AIR OCCUPIED HEATING CONTROL OCCUPIED COOLING CONTROL FAN CONTROL VFD OCCUPIED CO2 CONTROL PRIMARY AIR 1. THE DISCHARGE AIR TEMPERATURE SENSOR (DAT) SHALL ACTIVATE THE GAS FIRED HEATER IN ORDER TO MAINTAIN A MINIMUM SUPPLY TEMPERATURE OF 54F (ADJUSTABLE). 1. UPON A RISE IN DAT ABOVE THE COOLING SETPOINT THE COOLING CYCLE SHALL BE ACTIVATED. COOLING SETPOINT SHALL BE RESET AS WARM AS POSSIBLE (BETWEEN 55'F MINIMUM AND 60'F MAXIMUM) WITH THE FOLLOWING LIMITS: a) NO ROOM TEMPERATURE (FOR ALL ASSOCIATED FAN BOXES) IS MORE THAN 1'F ABOVE THE COOLING SETPOINT. b) THE DISCHARGE AIR DEW POINT IS NO MORE THAN 57'F. 2. THE FIRST MEANS OF MAINTAINING DISCHARGE AIR TEMPERATURE SHALL BE ACTIVATION OF THE ECONOMIZER. IF THE OUTSIDE AIR ENTHALPY, AS MEASURED BY THE OUTSIDE AIR ENTHALPY SENSOR IS BELOW THE RETURN AIR ENTHALPY, THE EXHAUST, OUTDOOR, AND RETURN AIR DAMPERS SHALL BE PROPORTION MODULATED TO 100% OUTDOOR AIR TO MAINTAIN SETPOINT. IF ADDITIONAL COOLING IS REQUIRED THE CONDENSING UNIT'S COMPRESSORS SHALL BE STAGED ON AS REQUIRED. DAT SHALL SHALL LIMIT SUPPLY AIR TEMPERATURE TO 55'F MINIMUM. 3. IF THE OUTSIDE AIR ENTHALPY RISES ABOVE THE SETPOINT THE ECONOMIZER SHALL BE POSITIONED TO PROVIDE MINIMUM VENTILATION AIR AND THE CONDENSING UNIT STAGED TO MAINTAIN ROOM COOLING SETPOINT TEMPERATURE. DAT SHALL LIMIT SUPPLY AIR TO 55' MINIMUM. GAS /ELECTRIC ROOFTOP UNIT CONTROL SEQUENCES (VAV) SERIES FAN POWERED BOX WITH ELECTRIC HEATING AND CO2 CONTROL SEQUENCES GENERAL SUPPLY AIR 1. FAN POWERED BOX SHALL BE CONTROLLED BY AN APPLICATION SPECIFIC CONTROLLER (ASC). COORDINATE OCCUPIED /UNOCCUPIED SCHEDULES WITH OWNER. ALL SETPOINTS SHALL BE ADJUSTABLE. 2. ALL TEMPERATURES LISTED ARE FAHRENHEIT AND SHALL BE ADJUSTABLE. 3. OCCUPIED HEATING SETPOINT SHALL BE 69'F. OCCUPIED COOLING SETPOINT SHALL BE 5'F WARMER THAN HEATING SETPOINT. 4. ROOM TEMPERATURES SHALL BE SET BY A WALL MOUNTED ADJUSTABLE T -STAT. 5. MAXIMUM PRIMARY AIRFLOW IS SHOWN ON DRAWINGS. MINIMUM PRIMARY AIR FLOW SHALL BE 30% OR AS SHOWN ON DRAWINGS. 6. PROVIDE WALL MOUNTED CONTROLLER BY RTU MANUFACTURER TO INTERLOCK FAN BOXES WITH ROOFTOP UNIT. WHILE IN UNOCCUPIED MODE, FAN SHALL BE OFF WITH THE PRIMARY AIR DAMPER (PAD) CLOSED AND THE ELECTRIC HEATING COIL (EHC) OFF. 2. WHEN BOX IS STARTED IN OCCUPIED MODE, THE PAD SHALL OPEN TO MINIMUM AIRFLOW AND THE FAN SHALL START AND RUN CONTINUOUSLY. 1. WHEN CO2 LEVEL AT SENSOR (C) RISES ABOVE 750 PPM THE CONTROLLER SHALL OVERRIDE THE COOLING SIGNAL TO THE PAD TO INCREASE PRIMARY AIR (UP TO MAXIMUM AIRFLOW) AS REQUIRED TO MAINTAIN THE CO2 LEVEL AT 750 PPM. 2. WHILE IN CO2 OVERRIDE THE ELECTRIC HEATING COIL SHALL MODULATE ON IN STAGES TO MAINTAIN THE SETPOINT. OCCUP ED HEATING CONTROL 1. UPON A CALL FOR HEATING FROM THE ROOM TEMPERATURE SENSOR (TR), THE PAD SHALL MODULATE TO ITS MINIMUM AIRFLOW (UNLESS IN CO2 OVERRIDE) AND THE ELECTRIC HEATING COIL (EHC) SHALL STAGE ON /OFF AS REQUIRED TO MAINTAIN THE HEATING SETPOINT. THE REVERSE SHALL OCCUR ON A RISE IN SPACE TEMPERATURE. OCCUPIED COOLING CONTROL 1. UPON A CALL FOR COOLING FROM THE ROOM TEMPERATURE SENSOR (TR), THE PAD SHALL MODULATE BETWEEN MINIMUM AND MAXIMUM AIR FLOWS AS REQUIRED TO MAINTAIN THE COOLING SETPOINT WITH THE ELECTRIC HEATING COIL OFF (UNLESS HEATING IS NEEDED DUE TO CO2 OVERRIDE), MORNING WARM -UP: 1. FAN BOXES HAVE EITHER A TEMPERATURE SENSOR OR HARDWIRE TO RTU TO SIGNAL PAD TO OPEN 100% DURING MORNING WARM UP. REFER TO RTU SEQUENCES. UNOCCUPIED H 'TING CONTROL 1. IF, WHEN THE UNIT IS OFF, THE ROOM TEMPERATURE FALLS BELOW 56'F, THE FB FAN SHALL START WITH THE PAD CLOSED AND EHC SHALL BE STAGED TO MAINTAIN A DISCHARGE AIR TEMPERATURE (DAT) BETWEEN 85 AND 90'F. WHEN ROOM TEMPERATURE RISES ABOVE 60'F, THE EHC SHALL CYCLE OFF AND, AFTER A 1- MINUTE DELAY, THE FAN SHALL STOP. UNOCCUPIED COOLING CONTQI 1. THERE SHALL BE NO UNOCCUPIED COOLING. UNOCCUPIED OVERRIDE SAFETIES 1. 2. BUTTON ON TR SHALL ALLOW 2 -HOUR (ADJ) OVERRIDE FROM UNOCCUPIED TO OCCUPIED CONTROL. WHEN ANY ROOM IS IN THIS OVERRIDE, THE CONTROL SYSTEM SHALL ENSURE THAT ENOUGH "UNOCCUPIED" ZONES ARE ALSO OVERRIDDEN SO THAT THE ASSOCIATED AIR HANDLER CAN OPERATE AT MINIMUM AIR FLOW IN THIS MODE. WHEN THE ASSOCIATED RTU UNIT SMOKE DETECTOR IS ACTIVATED THE FAN BOX SHALL BE COMMANDED OFF. PROVIDE ALL NECESSARY COMPONENTS, WIRING, SOFTWARE, PROGRAMMING, TO MAKE INTERLOCK WITH RTU AND COMPLETE ALL SEQUENCES NOTED. SERIES FAN POWERED BOX WITH ELECTRIC HEATING AND CO2 CONTROL SEQUENCES (CONF RM) C T GAS HEATER WARM -UP CONTROL SAFETIES ALARMS UNOCCUPIED CONTROL 1. REFER TO FAN BOX CONTROL SEQUENCE. 2. PROVIDE 2 HOUR UNOCCUPIED OVERRIDE TO START UNIT IN OCCUPIED MODE BASED ON SIGNAL FROM FAN BOX THERMOSTAT OVERRIDE BUTTON. IN THIS MODE THE CONTROLS SHALL ENSURE THAT ENOUGH "UNOCCUPIED" ZONES ARE ALSO OVERRIDDEN SO THAT THE UNIT OPERATES WITH AT LEAST 20% OF DESIGN AIR FLOW. RESET THE MINIMUM OUTDOOR AIRFLOW TO 20% OF SCHEDULED MINIMUM OUTDOOR AIRFLOW. 1. MICROPROCESSOR SHALL PROVIDE OPTIMUM START CAPABILITY. IF SPACE TEMPERATURE IS BELOW 65'F, WARM -UP SHALL BE DONE WITH RAD OPEN, OAD AND EAD CLOSED, AND GAS HEAT CONTROLLED BY DAT TO SUPPLY 90'F AIR. WHEN ROOM TEMPERATURE RISES TO 69'F, OCCUPIED MODE SHALL START. 1. THE FOLLOWING SAFETIES EACH WITH ITS OWN MANUAL RESET BUTTON, SHALL SHUT DOWN THE RTU VIA HARDWARE BEFORE H -O -A. a) WHEN ANY SMOKE DETECTOR (SDET) IS ACTIVATED THE UNIT SHALL SHUT DOWN. THE CONTROLLER SHALL COMMAND ALL FAN BOXES OFF. 1. IF THE SUPPLY OR RETURN FAN FAILS OR IF ANY UNIT SAFETY IS TRIPPED, THE CONTROLLER SHALL GIVE A DETAILED ALARM SIGNAL TO THE FONT END. 2. IF FILTER PRESSURE DROP EXCEEDS SETPOINT (INITIALLY 0.6 ") FOR TEN MINUTES, THE CONTROLLER SHALL GIVE A DETAILED ALARM SIGNAL TO THE FRONT END. Rev levy ei) f CODE COMPLIANC APPROVED ©�1 0 9 2008 ---oty Of TUl"W to %so B flOB2o ( SUPPLY ) AIR South Seattle Branch 304 Strander Blvd. Seattle, WA 98188 Gensler ENGINEERS IA Issue 01 1 Seal/Signature Project Name Fidelity Investor Center - SEATTLE BRANCH I Project Number 20080075 I CAD File Name 20080075106.01 I Description HVAC CONTROL DIAGRAM I Scale NTS H06.01 Q2006 Gensler Fidelity I IVVESTME VTS Date & Issue Description By 07/02/08 KJL ISSUED FOR CONSTRUCTION 133 Federal Street 5th Floor Boston MA 02110 Telephone 617.292.4400 Facsimile 617.292.4401 Richard D. Kimball Company, Inc Seaport Center 70 Fargo Street Suite 801 Boston, MA 02 21 0 -1 964 T 617- 345 -9885 F 617 -345 -4226 W www.rdkengineers.com RECEIVED 1SEP 3 0 zoos PERMIT CENTE:. Check TPW ATC NOTE: PROVIDE WALL MOUNTED CONTROLLER SIMILAR TO JCI "COMERCIAL COMFORT SYSTEMS" CAPABLE OF INTERLOCKING VAV FAN BOXES WITH RTU. CONTROLLER SHALL BE CAPABLE OF PROGRAMMING RTU AND FAN BOXES FOR OCCUPIED AND UNOCCUPIED MODE FOR 7 -DAYS. LOCAL THERMOSTATS SHALL BE CAPABLE OF 2 -HR OVERRIDE. ECUH -1 RA FROM RM SA TO ROOM VESTIBU CEILING MOUNTED EL CTRIC CABINET UNIT HEATER: GENERAL 1. THE FAN AND ELECTRIC HEATING COIL SHALL BE CONTROLLED BY T -STAT MOUNTED IN RETURN GRILLE. CONTROL SEQUENCE 1. WHEN THE SENSOR LOCATED IN THE ASSOCIATED RETURN GRILLE SENSES A DROP IN SPACE TEMPERATURE BELOW SETPOINT (72T ADJ) THE FAN SHALL ENERGIZE AND THE ELECTRIC COIL SHALL STAGE ON /OFF AS REQUIRED UNTIL SENSOR IS SATISFIED FOR A PERIOD OF 5 MINUTES. m CEILING MOUNTED ECUH CONTROL SEQUENCE UH -1 T ) TO ROOM MECHANICAL ROOM CEILING MOUNTED ELECTRIC CABINET UNIT HEATER: GENERAL 1. THE FAN AND ELECTRIC HEATING COIL SHALL BE CONTROLLED BY A UNIT MOUNTED T -STAT. CONTROL SEQUENCE 1. WHEN THE UNIT MOUNTED T -STAT SENSES A DROP IN SPACE TEMPERATURE BELOW SETPOINT (50'F ADJ) THE FAN SHALL ENERGIZE AND THE ELECTRIC COIL SHALL STAGE ON /OFF AS REQUIRED UNTIL SENSOR IS SATISFIED FOR A PERIOD OF 5 MINUTES. 2. PROVIDE ALL SAFETIES AND INTEGRAL COMPONENTS NECESSARY IN ORDER TO COMPLETE THIS SEQUENCE OF OPERATION. D VERTICAL MOUNTED UH CONTROL SEQUENCE M: \2008\20080075- Fidelity Seattle, WA \Hvac \20080075 H06 01 HVAC CONTROL DIAGRAM.dwa [30x42] Septernber 23, 2008 - 4:05pm cbutts CRAC CONTROL SEQUENCE. A. GENERAL C. ALARMS FROM LAN RM TO LAN RM ACCU -XM ON ROOF 1. CRAC SHALL BE CONTROLLED, ON AN INDIVIDUAL BASIS BY A MANUFACTURER SUPPLIED PACKAGE CONTROL UNIT 2. THIS SEQUENCE APPLIES TO CRAC =XM. 3. UNIT SETPOINT SHALL BE ADJUSTABLE BY THE UNIT CONTROLLER. 4. ALL UNIT ALARMS SHALL BE DISPLAYED LOCALLY AND SPECIFIC ALARMS SHALL BE TRANSMITTED TO A MANUFACTURER SUPPLIED REMOTE MONITORING PANEL LOCATED IN THE LAN ROOM. B. INDIVIDUAL CRAC CONTROL 1. SPACE TEMPERATURE a. LOCAL TEMPERATURE SHALL BE SENSED BY THE UNIT'S RETURN AIR TEMPERATURE SENSOR. b. WHEN LOCAL TEMPERATURE RISES ABOVE THE SETPOINT OF 72'F(ADJUSTABLE) THE ROOF MOUNTED CONDENSING UNIT SHALL ENERGIZE. c. THE CRAC FAN SHALL RUN CONTINUOUSLY 24/7. a. ALARMS SHALL BE GENERATED BY THE FOLLOWING CONDITIONS. I. RETURN AIR TEMPERATURE ABOVE 80'F FOR LONGER THEN 5 MINUTES(ADJUSTABLE). ii. RETURN AIR TEMPERATURE BELOW 60'F FOR LONGER THEN 5 MINUTES.(ADJUSTABLE). iii LEAK DETECTOR ACTIVATION. D. OFF SITE MONITORING. THE ALARM PANEL SHALL HAVE A MODEM CONNECTION CAPABLE OF SENDING ALARM SIGNALS, VIA A INTERNET CONNECTION, TO AN OFF SITE MONITORING STATION. CRAC -XM CONTROL SEQUENCES EXHAUST FANS: GENERAL 1. THE EXHAUST FANS EF- 1XM,2XM SHALL BE RUN CONTINUOUSLY DURING BUILDING OCCUPIED HOURS. FAN CONTROL 1. THE FAN SHALL BE ACTIVATED VIA THE LIGHTING CONTROL PANEL. UPON ACTIVATION THE EXHAUST AIR DAMPER(EAD) SHALL OPEN AND THE FAN ENABLED. EXHAUST EXHAUST FAN CONTROL EF -1 XM,2XM BDD EXHAUST FANS: GENERAL FAN CONTROL EXHAUST BDD EF -3XM 1. THE EXHAUST FAN EF -3XM SHALL BE CONTROLLED VIA REVERSE ACTING SPACE MOUNTED THERMOSTAT. 1. THE FAN SHALL ACTIVATED WHEN SPACE THERMOSTAT SENSES A RISE IN TEMPERATURE ABOVE 85'F (ADJ). WHEN THE T -STAT IS SATISFIED FOR A PERIOD OF FIVE MINUTES THE FAN SHALL DEACTIVATE. D 0 EXHAUST FAN CONTROL GENERAL FAN CONTROL OCCUPIED HEATING CONTRQL OCCUPIED COOLING CONTROL UNOCCUPIED HEATING CONTROL UNOCCUPIED COOLING CONTROL 1. THERE SHALL BE NO UNOCCUPIED COOLING. UNOCCUPIED OVERRIDE D PRIMARY AIR SERIES FAN POWERED BOX WITH ELECTRIC HEATING CONTROL SEQUENCES SUPPLY AIR 1. FAN POWERED BOX SHALL BE CONTROLLED BY AN APPLICATION SPECIFIC CONTROLLER (ASC). COORDINATE OCCUPIED /UNOCCUPIED SCHEDULES WITH OWNER. ALL SETPOINTS SHALL BE ADJUSTABLE. ALL ACTUATORS SHALL BE ELECTRONIC. 2. ALL TEMPERATURES LISTED ARE FAHRENHEIT AND SHALL BE ADJUSTABLE. 3. OCCUPIED HEATING SETPOINT SHALL BE 69'F. OCCUPIED COOLING SETPOINT SHALL BE 5'F WARMER THAN HEATING SETPOINT. 4. ROOM TEMPERATURES SHALL BE SET BY A WALL MOUNTED ADJUSTABLE T -STAT. 5. MAXIMUM PRIMARY AIRFLOW IS SHOWN ON PLANS. MINIMUM PRIMARY AIRFLOW SHALL BE 30% OR AS SHOWN ON DRAWINGS 6. PROVIDE WALL - MOUNTED CONTROLLER BY RTU MANUFACTURER TO INTERLOCK FAN BOXES WITH ROOFTOP UNIT. 1. WHILE IN UNOCCUPIED MODE, FAN SHALL BE OFF WITH THE PRIMARY AIR DAMPER (PAD) CLOSED AND THE ELECTRIC HEATING COIL (EHC) OFF. 2. WHEN BOX IS STARTED IN OCCUPIED MODE, THE PAD SHALL OPEN TO MINIMUM AIRFLOW AND THE FAN SHALL START AND RUN CONTINUOUSLY. 1. UPON A CALL FOR HEATING FROM THE ROOM TEMPERATURE SENSOR (TR), THE PAD SHALL MODULATE TO ITS MINIMUM AIRFLOW AND THE EHC SHALL BE ENERGIZED IN STAGES AS REQUIRED TO MAINTAIN THE HEATING SETPOINT. THE REVERSE SHALL OCCUR ON A RISE IN SPACE TEMPERATURE. 1. UPON A CALL FOR COOLING FROM THE ROOM TEMPERATURE SENSOR (TR), THE PAD SHALL MODULATE BETWEEN MINIMUM AND MAXIMUM AIR FLOWS AS REQUIRED TO MAINTAIN THE COOLING SETPOINT WITH THE EHC OFF, MORNING WARM -UP. 1. FAN BOXES HAVE EITHER A TEMPERATURE SENSOR OR HARDWIRE TO RTU TO SIGNAL PAD TO OPEN 100% DURING MORNING WARM UP. REFER TO RTU SEQUENCES. 1. IF, WHEN THE UNIT IS OFF, THE ROOM TEMPERATURE FALLS BELOW 56'F, THE FB FAN SHALL START WITH THE PAD CLOSED AND EHC SHALL BE STAGED TO MAINTAIN A DISCHARGE AIR TEMPERATURE (DAT) BETWEEN 85 AND 90'F (ADJ). WHEN ROOM TEMPERATURE RISES ABOVE 60'F, THE EHC SHALL CYCLE OFF AND, AFTER A 1- MINUTE DELAY, THE FAN SHALL STOP. 1. BUTTON ON TR SHALL ALLOW 2 -HOUR (ADJ) OVERRIDE FROM UNOCCUPIED TO OCCUPIED CONTROL. WHEN ANY ROOM IS IN THIS OVERRIDE, THE CONTROL SYSTEM SHALL ENSURE THAT ENOUGH "UNOCCUPIED" ZONES ARE ALSO OVERRIDDEN SO THAT THE ASSOCIATED AIR HANDLER CAN OPERATE AT MINIMUM AIR FLOW IN THIS MODE. SAFETIES 1. WHEN THE ASSOCIATED RTU UNIT SMOKE DETECTOR IS ACTIVATED THE FAN BOX SHALL BE COMMANDED OFF. 2. PROVIDE ALL NECESSARY COMPONENTS, WIRING, SOFTWARE, PROGRAMMING, TO MAKE INTERLOCK WITH RTU AND COMPLETE ALL SEQUENCES NOTED. SERIES FAN POWERED BOX WITH ELECTRIC HEATING CONTROL SEQUENCES ROOF TOP UNIT CONTROLS: GENERAL FAN CONTROL RELIEF AIR OUTDOOR io AIR BDD (ADJUSTABLE) 1. ROOFTOP UNIT SHALL BE STARTED AND STOPPED VIA DEDICATED MICROPROCESSOR CONTROLLER, WALL MOUNTED IN SPACE. COORDINATE OCCUPIED/ UNOCCUPIED SCHEDULES WITH OWNER. ALL SETPOINTS SHALL BE ADJUSTABLE. 2. LOCAL HAND -OFF- AUTOMATIC SWITCH (H -O -A) FOR FANS SHALL OVERRIDE CONTROLLER START /STOP (S /S) COMMANDS. ALL HARDWIRED SAFETIES SHALL BE ACTIVE IN BOTH "H" AND "A" POSITIONS. ■ If 3. ALL TEMPERATURES LISTED ARE FAHRENHEIT. 4. PROVIDE APPROPRIATE ANTI- RECYCLE TIME DELAYS ON COMPRESSOR. 5. MINIMUM OUTSIDE AIR SHALL BE 780 CFM FOR RTU -1XM AND 540 CFM FOR RTU -2XM. 1. WHILE IN THE OFF MODE (OR ON SAFETY OR MANUAL DISCONNECT) RTU SUPPLY FAN SHALL BE OFF WITH THE OUTSIDE AIR DAMPER (OAD) AND POWERED EXHAUST DAMPER CLOSED, THE CONDENSING UNIT AND GAS HEATER OFF, AND THE RETURN AIR DAMPER (RAD) OPEN. 2. WHEN STARTED IN OCCUPIED MODE, THE RTU FAN SHALL START IN RECIRCULATION MODE (100% RETURN AIR) AT MINIMUM SPEED. 3. THE FAN VFD SHALL SLOWLY INCREASE IN SPEED TO MAINTAIN SETPOINT OF REMOTE DIFFERENTIAL PRESSURE SENSOR (DPS). INITIAL SETPOINT SHALL BE 1.25" W.G. WITH FINAL SETPOINT DETERMINED BY THE BALANCING CONTRACTOR TO BE AS LOW AS NEEDED TO PROVIDE FULL AIRFLOW TO THE MOST REMOTE TERMINAL BOXES WITH THEIR PRIMARY AIR DAMPERS AT LEAST 95% OPEN. 4. AFTER STARTUP, ONCE FAN OPERATION IS STABLE, THE OAD AND THE RAD SHALL SLOWLY OPEN TO MINIMUM OUTDOOR AIR POSITION. ©Dd ✓ /ii,ruD I NO ..s .ir rr. . ! ] RETURN AIR OCCUPIED HEATING CONTROL OCCUPIED COOLING CONTROL FAN CONTROL VFD OCCUPIED CO2 CONTROL PRIMARY AIR 1. THE DISCHARGE AIR TEMPERATURE SENSOR (DAT) SHALL ACTIVATE THE GAS FIRED HEATER IN ORDER TO MAINTAIN A MINIMUM SUPPLY TEMPERATURE OF 54F (ADJUSTABLE). 1. UPON A RISE IN DAT ABOVE THE COOLING SETPOINT THE COOLING CYCLE SHALL BE ACTIVATED. COOLING SETPOINT SHALL BE RESET AS WARM AS POSSIBLE (BETWEEN 55'F MINIMUM AND 60'F MAXIMUM) WITH THE FOLLOWING LIMITS: a) NO ROOM TEMPERATURE (FOR ALL ASSOCIATED FAN BOXES) IS MORE THAN 1'F ABOVE THE COOLING SETPOINT. b) THE DISCHARGE AIR DEW POINT IS NO MORE THAN 57'F. 2. THE FIRST MEANS OF MAINTAINING DISCHARGE AIR TEMPERATURE SHALL BE ACTIVATION OF THE ECONOMIZER. IF THE OUTSIDE AIR ENTHALPY, AS MEASURED BY THE OUTSIDE AIR ENTHALPY SENSOR IS BELOW THE RETURN AIR ENTHALPY, THE EXHAUST, OUTDOOR, AND RETURN AIR DAMPERS SHALL BE PROPORTION MODULATED TO 100% OUTDOOR AIR TO MAINTAIN SETPOINT. IF ADDITIONAL COOLING IS REQUIRED THE CONDENSING UNIT'S COMPRESSORS SHALL BE STAGED ON AS REQUIRED. DAT SHALL SHALL LIMIT SUPPLY AIR TEMPERATURE TO 55'F MINIMUM. 3. IF THE OUTSIDE AIR ENTHALPY RISES ABOVE THE SETPOINT THE ECONOMIZER SHALL BE POSITIONED TO PROVIDE MINIMUM VENTILATION AIR AND THE CONDENSING UNIT STAGED TO MAINTAIN ROOM COOLING SETPOINT TEMPERATURE. DAT SHALL LIMIT SUPPLY AIR TO 55' MINIMUM. GAS /ELECTRIC ROOFTOP UNIT CONTROL SEQUENCES (VAV) SERIES FAN POWERED BOX WITH ELECTRIC HEATING AND CO2 CONTROL SEQUENCES GENERAL SUPPLY AIR 1. FAN POWERED BOX SHALL BE CONTROLLED BY AN APPLICATION SPECIFIC CONTROLLER (ASC). COORDINATE OCCUPIED /UNOCCUPIED SCHEDULES WITH OWNER. ALL SETPOINTS SHALL BE ADJUSTABLE. 2. ALL TEMPERATURES LISTED ARE FAHRENHEIT AND SHALL BE ADJUSTABLE. 3. OCCUPIED HEATING SETPOINT SHALL BE 69'F. OCCUPIED COOLING SETPOINT SHALL BE 5'F WARMER THAN HEATING SETPOINT. 4. ROOM TEMPERATURES SHALL BE SET BY A WALL MOUNTED ADJUSTABLE T -STAT. 5. MAXIMUM PRIMARY AIRFLOW IS SHOWN ON DRAWINGS. MINIMUM PRIMARY AIR FLOW SHALL BE 30% OR AS SHOWN ON DRAWINGS. 6. PROVIDE WALL MOUNTED CONTROLLER BY RTU MANUFACTURER TO INTERLOCK FAN BOXES WITH ROOFTOP UNIT. WHILE IN UNOCCUPIED MODE, FAN SHALL BE OFF WITH THE PRIMARY AIR DAMPER (PAD) CLOSED AND THE ELECTRIC HEATING COIL (EHC) OFF. 2. WHEN BOX IS STARTED IN OCCUPIED MODE, THE PAD SHALL OPEN TO MINIMUM AIRFLOW AND THE FAN SHALL START AND RUN CONTINUOUSLY. 1. WHEN CO2 LEVEL AT SENSOR (C) RISES ABOVE 750 PPM THE CONTROLLER SHALL OVERRIDE THE COOLING SIGNAL TO THE PAD TO INCREASE PRIMARY AIR (UP TO MAXIMUM AIRFLOW) AS REQUIRED TO MAINTAIN THE CO2 LEVEL AT 750 PPM. 2. WHILE IN CO2 OVERRIDE THE ELECTRIC HEATING COIL SHALL MODULATE ON IN STAGES TO MAINTAIN THE SETPOINT. OCCUP ED HEATING CONTROL 1. UPON A CALL FOR HEATING FROM THE ROOM TEMPERATURE SENSOR (TR), THE PAD SHALL MODULATE TO ITS MINIMUM AIRFLOW (UNLESS IN CO2 OVERRIDE) AND THE ELECTRIC HEATING COIL (EHC) SHALL STAGE ON /OFF AS REQUIRED TO MAINTAIN THE HEATING SETPOINT. THE REVERSE SHALL OCCUR ON A RISE IN SPACE TEMPERATURE. OCCUPIED COOLING CONTROL 1. UPON A CALL FOR COOLING FROM THE ROOM TEMPERATURE SENSOR (TR), THE PAD SHALL MODULATE BETWEEN MINIMUM AND MAXIMUM AIR FLOWS AS REQUIRED TO MAINTAIN THE COOLING SETPOINT WITH THE ELECTRIC HEATING COIL OFF (UNLESS HEATING IS NEEDED DUE TO CO2 OVERRIDE), MORNING WARM -UP: 1. FAN BOXES HAVE EITHER A TEMPERATURE SENSOR OR HARDWIRE TO RTU TO SIGNAL PAD TO OPEN 100% DURING MORNING WARM UP. REFER TO RTU SEQUENCES. UNOCCUPIED H 'TING CONTROL 1. IF, WHEN THE UNIT IS OFF, THE ROOM TEMPERATURE FALLS BELOW 56'F, THE FB FAN SHALL START WITH THE PAD CLOSED AND EHC SHALL BE STAGED TO MAINTAIN A DISCHARGE AIR TEMPERATURE (DAT) BETWEEN 85 AND 90'F. WHEN ROOM TEMPERATURE RISES ABOVE 60'F, THE EHC SHALL CYCLE OFF AND, AFTER A 1- MINUTE DELAY, THE FAN SHALL STOP. UNOCCUPIED COOLING CONTQI 1. THERE SHALL BE NO UNOCCUPIED COOLING. UNOCCUPIED OVERRIDE SAFETIES 1. 2. BUTTON ON TR SHALL ALLOW 2 -HOUR (ADJ) OVERRIDE FROM UNOCCUPIED TO OCCUPIED CONTROL. WHEN ANY ROOM IS IN THIS OVERRIDE, THE CONTROL SYSTEM SHALL ENSURE THAT ENOUGH "UNOCCUPIED" ZONES ARE ALSO OVERRIDDEN SO THAT THE ASSOCIATED AIR HANDLER CAN OPERATE AT MINIMUM AIR FLOW IN THIS MODE. WHEN THE ASSOCIATED RTU UNIT SMOKE DETECTOR IS ACTIVATED THE FAN BOX SHALL BE COMMANDED OFF. PROVIDE ALL NECESSARY COMPONENTS, WIRING, SOFTWARE, PROGRAMMING, TO MAKE INTERLOCK WITH RTU AND COMPLETE ALL SEQUENCES NOTED. SERIES FAN POWERED BOX WITH ELECTRIC HEATING AND CO2 CONTROL SEQUENCES (CONF RM) C T GAS HEATER WARM -UP CONTROL SAFETIES ALARMS UNOCCUPIED CONTROL 1. REFER TO FAN BOX CONTROL SEQUENCE. 2. PROVIDE 2 HOUR UNOCCUPIED OVERRIDE TO START UNIT IN OCCUPIED MODE BASED ON SIGNAL FROM FAN BOX THERMOSTAT OVERRIDE BUTTON. IN THIS MODE THE CONTROLS SHALL ENSURE THAT ENOUGH "UNOCCUPIED" ZONES ARE ALSO OVERRIDDEN SO THAT THE UNIT OPERATES WITH AT LEAST 20% OF DESIGN AIR FLOW. RESET THE MINIMUM OUTDOOR AIRFLOW TO 20% OF SCHEDULED MINIMUM OUTDOOR AIRFLOW. 1. MICROPROCESSOR SHALL PROVIDE OPTIMUM START CAPABILITY. IF SPACE TEMPERATURE IS BELOW 65'F, WARM -UP SHALL BE DONE WITH RAD OPEN, OAD AND EAD CLOSED, AND GAS HEAT CONTROLLED BY DAT TO SUPPLY 90'F AIR. WHEN ROOM TEMPERATURE RISES TO 69'F, OCCUPIED MODE SHALL START. 1. THE FOLLOWING SAFETIES EACH WITH ITS OWN MANUAL RESET BUTTON, SHALL SHUT DOWN THE RTU VIA HARDWARE BEFORE H -O -A. a) WHEN ANY SMOKE DETECTOR (SDET) IS ACTIVATED THE UNIT SHALL SHUT DOWN. THE CONTROLLER SHALL COMMAND ALL FAN BOXES OFF. 1. IF THE SUPPLY OR RETURN FAN FAILS OR IF ANY UNIT SAFETY IS TRIPPED, THE CONTROLLER SHALL GIVE A DETAILED ALARM SIGNAL TO THE FONT END. 2. IF FILTER PRESSURE DROP EXCEEDS SETPOINT (INITIALLY 0.6 ") FOR TEN MINUTES, THE CONTROLLER SHALL GIVE A DETAILED ALARM SIGNAL TO THE FRONT END. Rev levy ei) f CODE COMPLIANC APPROVED ©�1 0 9 2008 ---oty Of TUl"W to %so B flOB2o ( SUPPLY ) AIR South Seattle Branch 304 Strander Blvd. Seattle, WA 98188 Gensler ENGINEERS IA Issue 01 1 Seal/Signature Project Name Fidelity Investor Center - SEATTLE BRANCH I Project Number 20080075 I CAD File Name 20080075106.01 I Description HVAC CONTROL DIAGRAM I Scale NTS H06.01 Q2006 Gensler Fidelity I IVVESTME VTS Date & Issue Description By 07/02/08 KJL ISSUED FOR CONSTRUCTION 133 Federal Street 5th Floor Boston MA 02110 Telephone 617.292.4400 Facsimile 617.292.4401 Richard D. Kimball Company, Inc Seaport Center 70 Fargo Street Suite 801 Boston, MA 02 21 0 -1 964 T 617- 345 -9885 F 617 -345 -4226 W www.rdkengineers.com RECEIVED 1SEP 3 0 zoos PERMIT CENTE:. Check TPW HANGER STRAPS OR RODS MAX. DUCT DIA. HANGER MAX. SPACING FEET 20" ONE 1" x 22 GA. STRAP 10 36" ONE 1" x 18 GA. STRAP 10 60" TWO 3/8" DIA. RODS 10 84" TWO 1 /2" DIA. RODS 10 NOTES: 1. CONTROLLER WITH MOUNTING BRACKET FASTENED TO THE INSIDE OF PLENUM WITH ACCESS TO CONTROL SHAFT THROUGH THE OPENING OF THE DIFFUSER. 2. BCW CASING AND STAINLESS WIRE EXITS PLENUM THROUGH A 4" HOLE THEN PARALLELS THE FLEX BACK TO DAMPER AT BRANCH DUCT TAKEOFF. 3. MODEL NUMBERS BASED ON THE YOUNG REGULATORS COMPANY. BCW CASING AND STAINLESS WIRE / 50 FEET MAXIMUM 270 -275 LOCKING GEAR DRIVE CONTROLLER KIT WRENCH REMOTE VOLUME DAMPER CONTROL FOR SLOT DIFFUSER CONTROL HSM004 INDICATOR TO SHOW OPEN /CLOSE /BALANCED POSITION BUTTERFLY BLADE LOCKING QUADRANT TYPE W /NON- METALLIC SHAFT AND EXTERNAL SHAFT BEARING MOUNTS NOTES: 1. DAMPER SHALL BE MFR. OF SAME MATERIAL AS DUCTWORK 2. GAUGE OF DAMPER TO BE (2) GAUGES HEAVIER THAN DUCTWORK © D m ROUND VOLUME DAMPER BELOW 14 "0 - LOW PRESSURE HSM014 ROUND DUCT RECTANGULAR DUCT FLEX CONN RECTANGULAR DUCT WHEN HEIGHT DOES NOT ALLOW FLEX CONN, HARD -DUCT BUT BE SURE BRANCH IS 4" WIDER THAN COLLAR TO ALLOW ALIGNMENT OF TERMINAL WITHIN GRID WITHOUT FISHMOUTHING. DUCT WIDTH = 4" GREATER THAN NECK / COLLAR DIMENSION TO ALLOW FOR CONNECTION W/0 FISHMOUTHING LC1 MAX. OFFSET = 1" MAX OFFSET = 1" HARD CONNECTION WHERE ALIGNMENT & SPACE DICTATE ONLY L r I I NOTES: 1. THESE DETAILS ALLOW DUCTWORK TO BE PROVIDED BEFORE CEILING GRID IS INSTALLED THEN DIFFUSER /REGISTER CAN BE POSITIONED INTO GRID. 2. PROVIDE INSULATED TRANSITION ROUND TO SQUARE IF REQUIRED AT DIFFUSER. 3. PROVIDE NYLON TY -WRAP TOOL OR REUSABLE SS DRAW BAND PER SPECS. 4. FLEX DUCT SHALL NOT HAVE MORE THAN 1/2" SAG PER FOOT. 5. LENGTH OF FLEX DUCT SHALL NOT EXCEED 6' -0". 6. PROVIDE DUCT MOUNTED VOLUME DAMPER WHENEVER POSSIBLE. TRY TO AVOID NECK DAMPERS. RECTANGULAR DUCT FLEX CONN. REFER TO SPECS FOR INSULATED TYPE SUPPLY DIFFUSER REGISTER (TYP.) R =DEPTH OF DUCT L D TYPICAL SUPPLY DIFFUSER/ REGISTER DUCTWORK & CONNECTION HSMO17 AUXILIARY DRAIN PAN - MATERIAL SHALL BE GALVANIZED SHEET METAL. 3/4" PVC /COPPER CD. DRAIN. LEAK DETECTION \-- CABLE AROUND THE PERIMETER OF THE UNIT TACK WELD OR RIVET (IF RIVETED SEAL AIR TIGHT W/ WATER BASED SEALANT OR CAULK) SUPPORTS ONTO CRAC UNIT. AUXILIARY DRAIN PAN PAN SUPPORT (TYPICAL) NOTE: 1. AUXILIARY DRAIN PAN SHALL BE NOT LESS THAN 3" LARGER THAN THE UNIT AND WITH A MINIMUM DEPTH OF 1.5 INCHES. MINIMUM THICKNESS OF THE GALVANIZED PAN SHALL BE NOT LESS THAN 0.0276 -INCH. 2. PROVIDE DRAIN PAN FOR CRAC -XM. © ® AUXILIARY DRAIN AND ASSOCIATED SUPPORT HSM008 M: \2008 \20080075- Fidelity Seattle, WA \Hvac \20080075 H07.01 HVAC DETAILS.dwg [30x42] September 23, 2008 - 4:05pm cbutts SEE SPECS FOR SEALING AND USING NYLON TY-WRAP TIGHTENED WITH TY -WRAP TOOL OR REUSABLE SS DRAW BAND INTERNALLY INSULATED PLENUM WITH INTEGRAL (NOT FIELD FABRICATED) LINEAR DIFFUSER BY DIFFUSER MANUFACTURER (USE NON-INSULATED BOOT FOR APPLICATION, SEE SPEC) ADJUSTABLE VANES NOTES: 1. OFFSETS WITH FLEX DUCT SHALL NOT EXCEED 30' AND SHALL BE GRADUAL. OFFSETS IN EXCESS OF 30' SHALL BE HARD DUCTED. 2. FLEX DUCT SHALL NOT HAVE MORE THAN 1/2" SAG /FT. 3. FOR PERIMETER DIFFUSERS LOCATE DISTANCE FROM OUTSIDE WALL SHOWN ON ARCH PLANS. 4. CONNECTION TO MAIN DUCT SHALL BE HARD DUCT TRANSITION AND VOLUME DAMPER. 11I CEILING INSULATED FLEX CONN 1 FOOT MAX LENGTH D © LINEAR DIFFUSER CONNECTION HSM016 SEE NOTE 2 GALV. HANGER HANGER STRAP NOTES: 1. CUTTING AND PATCHING SHALL BE LIMITED TO A MINIMUM AS REQUIRED FOR PROPER INSTALLATION. 2. SUPPORTS SHALL BE SPACED AND SIZED AS PER SMACNA. D DUCT HANGER SUPPORT HSM008 LINED INLET SOUND DIVERTER (SEE PART PLAN) 1.5 D PLENUM AIR TA FILTER FLEX DUCT AS PER PLANS AND SPECIFICATIONS AIR VALVE 0 iiiiii NYLON TY -WRAP TIGHTENED WITH TY -WRAP TOOL OR SS DRAW BAND R =D 1.5 D ALT HEATING COIL LOCATION / / / / / / // / /// 6 ` / / / / / / / / / / /r// / / / / /// /_, iii ll%iiiIF __J 7 I FAN HEATING COIL (IF PROVIDED BY MANUFACTURER SEE SCHEDULE AND SPECIFICATIONS) 1 FAN CONTROL BOX FLEX CONNECTION (OUT OF AIRSTREAM) ALT HEATING COIL LOCATION PART PLAN (ELEV.) 3D MINIMUM 3 DUCT DIAMETERS OF STRAIGHT DUCT SUPPORT ROD RUBBER & SHEAR VIB ISOL FLEX CONNECTION (OUT OF AIRSTREAM) MINIMUM 3 DUCT DIAMETERS OF STRAIGHT DUCT NOTES: 1. BOXES WITH INTERNAL VIBRATION ISOLATORS MUST BE HARD DUCTED. 2. BOX SENSOR SHALL BE ORIENTED IN SAME PLANE AS ELBOW AND BE WITHIN 10' OF HORIZONTAL OR PER MANUFACTURER'S RECOMMENDATION. 3. FOR BOXES WHERE MANUFACTURER CAN NOT PROVIDE INTERNAL VIBRATION ISOLATORS USE FLEX DUCT AS SHOWN. LENGTH OF FLEX DUCT SHALL NOT EXCEED 12 ". 4. OFFSETS WITH FLEX DUCT SHALL NOT EXCEED 30' AND SHALL BE GRADUAL. OFFSETS IN EXCESS OF 30' SHALL BE HARD DUCTED. 5. FLEX DUCT SHALL NOT HAVE MORE THAN 1/2" SAG. 6. PROVIDE FLOW STRAIGHTENER IF STRAIGHT RUN CANNOT BE MAINTAINED. D m FAN BOX CONNECTIONS (SERIES) H0003 MINIMUM 16 GA. BAND HANGER RODS OVER 36" DIA. NOTES: 1. ALL SUPPORTS SHALL BE GALVANIZED STEEL FOR STEEL DUCT, STAINLESS STEEL FOR STAINLESS STEEL DUCT, OR ALUMINUM FOR ALUMINUM DUCT. 2. HANGERS MUST NOT DEFORM DUCT SHAPE. 3. ATTACHMENTS TO STRUCTURE SHALL BE PER SMACNA. LOAD RATED FASTENERS BAND SAME SIZE AS HANGER STRAP 36" DIA. & UNDER D ES ROUND METAL DUCT HANGERS HAS008 S PARTITION MAX. r 1/2" (TYP) NOTE 1 PIPE SLEEVE STEEL FRAME OF ANGLE 1- 1/4 "x1 -1/4 " x1/8" AROUND DUCT PERIMETER NOTE 1 DUCT PENETRATION SHOWN IS WHERE FIRE DAMPER IS NOT REQUIRED BY CODE. NOTES: 1. AT FIRE RATED PARTITIONS ADD ADDITIONAL LAYER OF FIRE SAFING INSULATION AROUND PENETRATIONS SO AS TO FILL CAVITY. 2. DUCT AND PIPE PENETRATIONS THROUGH CORRIDOR WALLS ABOVE THE CEILING ARE TO BE FIRE STOPPED AROUND THE PENETRATION. ©D DUCT & PIPE PENETRATIONS HPE001 NOTES: 1. SEE SPECIFICATION FOR HANGER SIZES. 111D PREFERRED METHOD: CEILING PLENUM 1" ACOUSTIC LINING N CEILING GRILLE SHEET METAL RETURN AIR BOOT (NO LINE OF SIGHT) • 1/2 W SUPPORT NUT MIN. 9 LB /CFT DENSITY RIGID INSULATION AT SHIELD 1� HEAVY DUTY CLEVII S HANGER (FOR 1/2" UP TO & INCLUDING 3" PIPE) GALVANIZED INSULATION SHIELD 12" LONG 7/7 - /7,, PIPE HANGER SUPPORT . 77 /L/1 7ZLL// L / /// _ r�fJ11 W 4 CEILING GRILLE ALTERNATE METHOD FOR LOW CEILING CLEARANCE ONLY: W SUPPORT STRAP W 1/ r/, 2 X W OR 3 FT MINIMUM CEILING L /JILL ///LLZILL /JILL //./ / / /Z / /// V _/ W CEILING O D ® RETURN AIR TRANSFER BOOT OPTIONS HAS001 DIRECT BOOT TERMINATION POINT AWAY FROM EQUIPMENT (NOISE) IN CEILING PLENUM AREA OF OPENING =AREA OF GRILLE ON BOTH SIDES W =WIDTH OF GRILLE AREA OF OPENING =1/2 AREA OF GRILLE ON BOTH ENDS, W =WIDTH OF GRILLE 1" ACOUSTICAL LINING NOTES: 1. CONTRACTOR SHALL PROVIDE RETURN AIR BOOTS FOR ALL RETURNS WHERE NOTED ON THE FLOOR PLANS. 2. CONTRACTOR SHALL POSITION BOOT SO THAT THE OPEN SIDE IS PERPENDICULAR TO THE NEAREST ROOM WALL. 3. IF SPACE RESTRICTS INSTALLATION AS DETAILED, SUBMIT PROPOSED ALTERNATIVE KEEPING NO LINE OF SIGHT BETWEEN GRILLE AND OPENINGS. 4. PROVIDE UNIT COST FOR EACH METHOD. HSMO22 EXPOSED EDGE OF DUCT LINER (TYP) SPRAY ADHESIVE TO SEAL EDGES. USE SAME ADHESIVE AS USED ON DUCT LINER FABRICATION BY DUCT LINER MANUFACTURER SPECIFIED. PROVIDE SHEET METAL NOSE PIECES FOR CLAMPING ENTIRE EDGE OF EXPOSED DUCT LINER. EDGE OF NOSE PIECES SHALL BE 1.5 INCHES WIDE MINIMUM SO THAT TAKE -OFF FITTING WILL SEAT PROPERLY. 0 D SEALING & SECURING EXPOSED DUCT LINER HSM003 VD PREFERRED TAKE -OFF FITTING BELLMOUTH BELLMOUTH MINI - BELLMOUTH CONNECTION MODEL BMD CONNECTION MODEL BMD W/ END FLAPS MODEL MBMD AIR FLOW BENT OVER DUCT SIZE 5" 6" 9" 10" 14" 16 " HOLE SIZE 8" 9" 10" 12" 13" 15" 17" 19" VD MINIMUM DUCT HEIGHT 9" * ALTERNATE TAKE -OFF FITTING 1" 1 12" 13" 14" 16" 20 DUCT SIZE 5 7" 8" 9" 12 " 14" 16" * ALTERNATE TAKE-OFF FITTING VD HOLE SIZE ALTERNATE ROUND BRANCH DUCT TAKE -OFFS DUCT HOLE MINIMUM HEH SIZE SIZE HEIGHT 6 x 4 7.5 x 5.5 7.5 10 x 4 11.5 x 5.5 7.5 16 x 4 17.5 x 5.5 7.5 24 x 4 25.5 x 5.5 7.5 6 x 5 7.5 x 6.5 8.5 10 x 5 11.5 x 6.5 8.5 16 x 5 17.5 x 6.5 8.5 24 x 5 25.5 x 6.5 8.5 6 x 6 7.5 x 7.5 9.5 10 x 6 11.5 x 7.5 9.5 16 x 6 17.5 x 7.5 9.5 24 x 6 25.5 x 7.5 9.5 8 x 8 9.5 x 9.5 11.5 16 x 8 17.5 x 9.5 11.5 24 x 8 25.5 x 9.5 11.5 10 x 10 11.5 x 11.5 13.5 16 x 10 17.5 x 11.5 13.5 24 x 10 25.5 x 11.5 13.5 7" 9" 9" 11" 11" 13" p MINIMUM HEIGHT SIZE SIZE 5" 6" 7" 9 "x 10- 9/16" 8" 9" x 12-1/8" 9" 9 "x 13 -11 16 "" 10" 9 "x 15 -1 /4" 12" 9 "x 18 - 3/8" 14" 9 "x 21 -1/2" 16" 9 "x 24 - 5/8" * ALTERNATE FITTING'S TO BE USED WHEN DUCT HEIGHT DOES NOT PERMIT THE USE OF THE FULL SIZE BELLMOUTH PREFERRED ALTERNATE TAKE -OFF FITTING TAKE -OFF FITTING PREFERRED RECTANGULAR BELL MOUTH FITTING MODEL RBMD AIR FLOW VD BRANCH * ALTERNATE TAKE -OFF FITTING OVAL- BELLMOUTH CONNECTION MODEL OVBMD VD MINIMUM DUCT DUCT HEIGHT SIZE 10" 10" 10" 10" 10" 10" 10" NOTES: ALL ROUND AND RECTANGULAR BELLMOUTH FITTINGS SHALL BE INCLUDED WITH THE FOLLOWING STANDARD FEATURES: 5" 5" x 10" 7" 6" 6" x 12" 8" x 8" 6 -1/2 " x 12" 8 2" 8-1/2" 9" 6 -1/2" x 14" 8 -1/2" 10" 6 -1/2" x 16" 8 -1/2" 12" 8-1/2" x 18" 10 -1/2" 14" 10" x 20" 12" 16" ALTERNATE 45' RECTANGULAR TAKE -OFF VD -� BRANCH _/\r- ALTERNATE RECTANGULAR BRANCH DUCT TAKE-OFF 1. NEOPRENE GASKET TO MINIMIZE AIR LEAKAGE. 2. PRE - DRILLED HOLES FOR QUICK MOUNTING. 3. CONSTRUCTED OF HEAVY GALVANIZED STEEL. 4. 26 GAUGE GALV. QUADRANT VOLUME DAMPER W/ TIGHT FITTING GASKETING TO MINIMIZE LEAKAGE AT DAMPER PIVOT POINTS. (FOR LOW PRESSURE DUCTWORK) * ALTERNATE TAKE -OFF FITTING STANDARD 45' RECTANGULAR TO ROUND BOOT CONNECTION MODEL 3300D V HOLE SIZE MINIMUM DUCT HEIGHT D TYPICAL DUCT TAKE -OFF HSMO21 PARTITION SEAL ALL AROUND MIN. 1.5 W MIN. 1/4 W 7 1.5 W J W -t J MIN. 1.5 W MIN. 1/4 W NOTES: 1. IF PARTITION IS FIRE RATED, PROVIDE FIRE DAMPER. 2. SEE PLANS FOR SIZE AND LOCATION OF RETURN AIR TRANSFER DUCTS. W =WIDTH OF DUCT STANDARD 1" ACOUSTICALLY LINED SHEET METAL OR FIBERGLASS - DUCTBOARD DUCT WITH MITERED RECTANGULAR ELBOW (NO VANES) REVIEWED EO CODE COM APPROVED OCT 0 9 1UOU City Of Tukwila B I'.. © >, .x,. ! INS D gi PLENUM TRANSFER DUCT HSM004 MAIN DUCT DUCT TAKE -OFF TAPERED CONNECTION 45' ANGLE(IF MAIN DUCT IS RECTANGULAR) OR CONICAL CONNECTION (IF MAIN DUCT IS ROUND) L =1/4 W; 4 "MIN - VD BRANCH DUCT > SUPPLY AIR <`-`-' RETURN /EXHAUST AIR D BRANCH TAKE -OFFS HSM001 CRAG DRAIN PAN �■ D CLEANOUT (TYP) DRAIN PIPE TO MATCH DRAIN OUTLET SIZE. ( 0 ) OVERSIZED LOOSE CAP LOCATED LEVEL WITH TOP OF DRAIN PAN. PIPE BELOW CAP SHALL HAVE FOUR Xi DEEP "V" SHAPED GROOVES TO ALLOW VISUAL OVERFLOW AND VENT FUNCTIONS. THIS DIMENSION IN INCHES MUST BE 1" GREATER THAN THE MAXIMUM FAN SUCTION STATIC PRESSURE IN INCHES W.C. (WITH DIRTY FILTERS, COILS, AND MAXIMUM AIR FLOW). cb> THIS DIMENSION IN INCHES MUST BE AT LEAST 1/2 OF (a). DRAW THRU UNIT CONDENSATE TRAP HPWO10 _ CE I ON Fidelity INVESTMENTS South Seattle Branch 304 Strander Blvd. Seattle, WA 98188 Gensler ENGINEERS L Issue 01 133 Federal Street 5th Floor Boston MA 02110 Telephone 617.292.4400 Facsimile 617.292.4401 Richard D. Kimball Company, Inc Seaport Center 70 Fargo Street Suite 801 Boston, MA 02210-1964 T 617- 345 -9885 F 617- 345 -4226 W www.rdkengineers.corn Date & Issue Description By Check 07/02/08 KJL TPW ISSUED FOR CONSTRUCTION Seal /Signature 1 Project Name 1 Project Number 20080075 CAD File Name 20080075) 107.01 Description HVAC DETAILS Scale NTS H07.01 Q2006 Gensler is Fidelity Investor Center - SEATTLE BRANCH RECEIVED ISEP 3 0 2008 PERMIT CENTI- SERIES FAN BOX SCHEDULE WITH ELECTRIC COIL TAG PRIMARY CFM RANGE PRIMARY INLET SIZE (IN.) DISCHARGE SIZE (IN.) AIRBORNE N.C. FAN DATA ELECTRIC COIL UNIT WEIGHT (LBS) MANUFACTURER AND MODEL NUMBER (AS STANDARD) REMARKS FULL SPEED FAN & 100% PRIMARY CFM EXT. S.P. MOTOR KW V PH STAGES W H S.P. O.P. HP V PH AMPS FB -1 225 -750 10" 11 11 36 33 750 0.35 1/4 277 1 2.0 5.0 480 3 2 81 JOHNSON CONTROLS TCS -EH 1011 SEE NOTES FB-- -2 180 -600 8 "o 11 11 36 34 600 0.35 1/6 277 1 1.0 2.0 277 1 1 78 JOHNSON CONTROLS TCS -EH 0806 SEE NOTES FB -3 105 -350 6 "0 11 11 37 30 350 0.35 1 /6 277 1 1.0 2.5 277 1 1 77 JOHNSON CONTROLS TCS -EH 0606 SEE NOTES FB -4 115-375 8 "0 11 11 37 30 375 0.35 1 /6 277 1 1.0 2.5 277 1 1 77 JOHNSON CONTROLS TGS -EH 0806 SEE NOTES FB -5 195 -640 8 "7i 11 11 31 27 640 0.35 1/4 277 1 2.0 4.0 480 3 2 81 JOHNSON CONTROLS TCS -EH 0811 SEE NOTES FB -6 260 -860 10 "o 11 11 32 30 860 0.35 1/4 277 1 2.0 3.0 480 3 2 81 JOHNSON CONTROLS TCS -EH 1011 SEE NOTES FB -7 255 -850 10 "0 11 11 36 33 900 0.35 1/4 277 1 2.0 3.0 480 3 2 81 JOHNSON CONTROLS TCS -EH 1011 SEE NOTES FB -B 420 -1 400 12 "0 11 11 37 30 1 400 0.35 1/2 277 1 3.6 9.0 480 3 3 79 JOHNSON CONTROLS ICS- EH 1218 SEE NOTES FB -9 80 -265 CO 11 11 37 30 265 0.35 1/6 277 1 1.0 1.0 277 1 1 77 JOHNSON CONTROLS TCS -EH 0606 SEE NOTES FB -10 420 -1410 12 "0 11 11 37 30 1410 0.35 1/2 277 1 3.6 9.0 480 3 3 79 JOHNSON CONTROLS TCS -EH 1218 SEE NOTES FB -11 60 -200 10 "0 11 11 22 20 200 0.35 1/6 277 1 1.0 0.75 277 1 1 77 JOHNSON CONTROLS TCS -EH 0606 SEE NOTES FB -12 420 -1400 12 % 11 11 37 30 1400 0.35 1/2 277 1 3.6 9.0 480 3 3 79 JOHNSON CONTROLS TCS -EH 1218 SEE NOTES 20 - 20 20 90 129 OFFICE 111 1 20 - 20 20 75 130 BREAK RM 206 6 120 - NOTES: 1. UNIT MOUNTED DISCONNECT (BY ELECTRICAL). 2. PROVIDE WALL MOUNTED CONTROL PACKAGE CAPABLE OF INTERLOCKING WITH FAN BOXES WITH RTU. 3. PROVIDE VIBRATION ISOLATION AS PER THESE SPECIFICATION. 4. PROVIDE PSC TYPE MOTOR. 5. PROVIDE ELECTRIC REHEAT IN STAGES AS SHOWN ON SCHEDULE. 6. PROVIDE (2) 1" THICK THROW AWAY FILTERS. 7. PROVIDE SINGLE POINT POWER CONNECTION. 8. PROVIDE UNIT MOUNTED ELECTRONIC SCR FAN SPEED CONTROLLER. VENTILATION SCHEDULE ROOM NUMBER SPACE DESIGNATION AREA (SOFT) CODE REQUIREMENTS DESIGN OA CFM RETURN AIR CFM EST. #PPL ( *1) GEM PER PERSON ( *2) EXHAUST CFM ( *3) REQUIRED CFM 100 VESTIBULE 45 NR NR NR NR NR NR 101 LOBBY 1211 - .05 /SF - 61 65 2745 101A TRANSACTION 207 2 20 - 40 40 175 103 MANAGER'S 163 1 20 12 "0 20 20 130 104 OFFICE 115 1 20 - 20 20 95 105 OFFICE 115 1 20 - 20 20 95 106 OFFICE 115 1 20 - 20 20 95 107 OFFICE 115 1 20 - 20 20 95 108 HALLWAY 337 - .05 /SF - 17 20 1380 109 CONFERENCE 380 30 20 - 600 600 465 110 STORAGE 17 NR NR NR NR NR NR 111 COAT 17 NR NR NR NR NR NR 112 HALLWAY 60 - .05 /SF - 3 5 25 113 UTILITY ROOM 72 NR NR NR NR NR NR 114 LAN RM 69 * EB 0 -225 8"0 24x24 EXHAUST 115 DIST 9 * * * * * * 116 HALLWAY 350 - .05 /SF - 18 20 1 117 OFFICE 111 1 20 - 20 20 105 118 OFFICE 111 1 20 - 20 20 105 119 OFFICE 111 1 20 - 20 20 105 120 OFFICE 111 1 20 - 20 20 110 121 ELECTRICAL 50 * * * * * * 122 HALLWAY 271 - .05 /SF - 14 15 125 123 OFFICE 111 1 20 - 20 20 140 124 OFFICE 111 1 20 - 20 20 140 125 OFFICE 111 1 20 - 20 20 140 126 OFFICE 111 1 20 - 20 20 140 127 OFFICE 111 1 20 - 20 20 140 128 OFFICE 111 1 20 - 20 20 90 129 OFFICE 111 1 20 - 20 20 75 130 BREAK RM 206 6 120 - 120 120 135 131 SUPPORT 200 3 60 - 60 60 125 132 MENS 200 .05 /SF 150 10 10 - 133 JANITOR'S 27 - .05 /SF 75 2 5 - 134 WOMENS 203 - .05 /SF 150 10 10 - 135 OPERATIONS 609 3 20 - 60 60 840 136 STORAGE 17 NR NR NR NR NR NR NOTES: NR NOT REQUIRED * ROOMS CONTAIN EQUIPMENT ONLY. THESE ARE NOT OCCUPIED SPACES. *1 BASED ON CODE REQUIRED FOR ESTIMATED MAX OCCUPANT LOAD. *2 CODE REQUIREMENT PER PERSON. *3 CODE REQUIRED EXHAUST. CODE REQUIRED VENTILATION AIR SUPPLY AND EXHAUST IS BASED ON 2006 SEATTLE MECHANICAL CODE SECTION 403 MECHANICAL VENTILATION TABLE 403.3 " REQUIRED OUTDOOR VENTILATION AIR' DIFFUSER, GRILLE & REGISTER SCHEDULE TAG SELECTION RANGE (CFM) NECK SIZE (IN.) OVERALL SIZE (IN.) SERVICE MOUNTING ACCESSORIES MANUFACTURER AND MODEL NUMBER (AS STANDARD) NC OR AIR PRESSURE DROP NOT TO EXCEED REMARKS SA 0 -125 6 "0 24x24 SUPPLY LAY -IN - TITUS PAS 30 SEE NOTES SB 126 -225 8"O 24x24 SUPPLY LAY -IN - TITUS PAS 30 SEE NOTES SC 0 -1250 15x15 24x24 SUPPLY LAY -IN - TITUS PAS 30 SEE NOTES SD 371 -450 12 "0 24x24 SUPPLY LAY -IN - TITUS PAS 30 SEE NOTES SE 76- 135/LF SEE DWG LINEAR SUPPLY BORDER 22 FBPI -20 -1 TITUS FL- 20- 1 -22 -JT 30 SEE NOTES SF 0-60/LE SEE DWG LINEAR SUPPLY SEE DWG 4. PROVIDE 2 -STAGE ELECTRIC HEATING COIL. TITUS ML -38 -48 2 SLOT 30 SEE NOTES SG 46-70/LE SEE DWG LINEAR SUPPLY BORDER 22 FBPI- 20-- -1 TITUS FL -20 -1 -22 -HT 30 SEE NOTES RA - - 24x24 RETURN LAY-IN - TITUS PAR 30 SEE NOTES RB 0- 1250 15x15 24x24 RETURN LAY -IN - TITUS PAR 30 SEE NOTES RC 46-70/LE SEE DWG LINEAR RETURN BORDER 22 - TITUS FLR- 20 -1 -22 30 SEE NOTES EA 226 -450 12 "0 24x24 EXHAUST LAY -IN - TITUS PAR 30 SEE NOTES EB 0 -225 8"0 24x24 EXHAUST LAY -IN - TITUS PAR 30 SEE NOTES NOTES: 1. PROVIDE TITUS INSULATED PLENUM ON SUPPLY LINEAR DIFFUSERS ONLY. 2. PROVIDE BLANK -OFF SECTIONS BETWEEN ACTIVE LINEAR FOR CONTINUOUS APPEARANCE. 3. REFER TO ARCHITECT'S PLAN FOR CONTINUOUS LINEAR RETURN AIR SLOTS FOR CORRIDOR AREAS. 4. COORDINATE FINISH W/ ARCHITECT. (DIFFUSER BORDER SHALL BE WHITE AND SLOT SHALL BE BLACK) 5. COORDINATE ALL BORDER TYPES WITH THE ARCHITECT'S FINAL CLNG GRID. 6. REFER TO DRAWINGS FOR LINEAR DIFFUSER LENGTHS. 7. PROVIDE MUD -IN TYPE BORDER FOR ALL LINEAR DIFFUSERS MOUNTED IN HARD GYP. CEILINGS. ELECTRIC CABINET & WALL HEATER SCHEDULE TAG LOCATION TYPE MOUNTING INPUT (kW) OUTPUT (MBH) AIR ELECTRIC SERVICE U WEIGHT ( Ds ) MANUFACTURER AND MODEL NUMBER (AS STANDARD) REMARKS CFM EAT (F) AMPS V PH ECUH -1 VESTIBULE HORIZ HUNG 3.0 10.2 250 75 95 12 277 1 120 0 -MARK CU935 SEE NOTES 1-7 UH -1 UTILITY RM VERT HUNG 3.0 10.2 350 75 102 11 277 1 27 Q- -MARK MUH03 -81 SEE NOTES 6 -9 NOTES: 1. UNIT MOUNTED DISCONNECT (BY ELECTRICAL). 2. PROVIDE TYPE C, CONCEALED CABINET, CASING W /FRONT & BACK DUCT COLLARS. 3, PROVIDE REMOTE MOUNTED TWO STAGE T -STAT. 4. PROVIDE 2 -STAGE ELECTRIC HEATING COIL. 5. PROVIDE UNIT WITH BOTTOM INLET AND TOP OUTLET CONFIGURATION. 6. PROVIDE VIBRATION ISOLATION AS PER THESE SPECIFICATIONS. 7. PROVIDE WHITE COLOR, COORDINATE WITH ARCHITECT. 8. PROVIDE WITH INTEGRAL T -STAT. 9. PROVIDE WHITE INTEGRAL DISCONNECT. M: \2008 \20080075- Fidelity Seattle, WA \Hvac \20080075 H08.01 HVAC SCHEDULES.dwg [30x42] September 23, 2008 - 4:05pm cbutts CODE COVIPLIAKE. APPROV oc_ 0 9 200 Ci f Tukwila IL©IN Gensler 1 Seal/Signature Project Name Project Number 20080075 1 CAD File Name 20080075_1108.01 Description HVAC SCHEDULES 1Scale NTS H08.01 02006 Gensler Fidelity INVESTMENTS South Seattle Branch 304 Strander Blvd. Seattle, WA 98188 ENGINEERS -- Issue Date & Issue Description By Check -- 01 07/02/08 KJL TPW ISSUED FOR CONSTRUCTION ti r Fidelity Investor Center - SEATTLE BRANCH 133 Federal Street 5th Floor Boston MA 02110 Telephone 617.292.4400 Facsimile 617.292.4401 Richard D. Kimball Company, Inc Seaport Center 70 Fargo Street Suite 801 Boston, MA 02210 -1964 T 617 -345 -9885 F 617 -345 -4226 W www.rdkengineers.com RECEIVFP ISEP 3 0 MA PERMIT CEN HVAC GENERAL NOTES 1. GENERAL NOTES APPLY TO ALL DRAWINGS. 2. THIS PROJECT INVOLVES CONSTRUCTION INSIDE AN EXISTING STRUCTURE. CONTRACTORS, BY SUBMITTING A BID, ARE DEEMED TO BE COMPLETELY FAMILIAR WITH THE EXISTING CONDITION OF THE BUILDING AS IT INFLUENCES THE WORK DESCRIBED. ABSOLUTELY NO CLAIMS FOR EXTRA COMPENSATION WILL BE CONSIDERED FOR EXISTING CONDITIONS VISIBLE OR REASONABLY INFERABLE FROM A CAREFUL EXAMINATION OF THE EXISTING BUILDING. 3. THIS CONTRACTOR SHALL INSPECT THE EXISTING FIELD CONDITIONS AT THE SITE AND THE "AS- BUILT' BASE BUILDING CONTRACT DOCUMENTS PRIOR TO THE START OF ANY WORK TO DETERMINE WHAT EFFECT THE EXISTING CONDITIONS WILL HAVE ON HIS WORK. POTENTIAL PROBLEM AREAS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND /OR ENGINEER IMMEDIATELY. 4. THIS CONTRACTOR SHALL CONNECT HIS WORK TO VARIOUS EXISTING DUCTWORK AND CONTROL SYSTEMS IN THE BASE BUILDING. THE NEW WORK SHALL BE COMPATIBLE WITH THE EXISTING SYSTEMS. LOCATION OF EQUIPMENT OR THE ROUTING OF THE VARIOUS SYSTEMS AS WELL AS OPENINGS IN FLOOR SLABS OR WALLS SHALL BE GOVERNED BY THE EXISTING CONDITIONS AS THEY APPEAR IN THE FIELD OR ON THE "AS- BUILT' DRAWINGS. 5. CARE SHALL BE TAKEN DURING THE INSTALLATION TO NOT DAMAGE OR INTERRUPT BUILDING SYSTEMS AND SERVICES THAT ARE ALREADY INSTALLED. DAMAGE TO SUCH SYSTEMS OR EQUIPMENT CAUSED BY THIS CONTRACTOR DURING INSTALLATION SHALL BE REPAIRED AND /OR REPLACED AT THIS CONTRACTOR'S EXPENSE TO THE COMPLETE SATISFACTION OF THE BUILDING OWNER. 6. SHUTDOWN OF EXISTING SYSTEMS FOR CONNECTION TO EXISTING SERVICES SHALL BE COORDINATED WITH THE CONSTRUCTION MANAGER OR GENERAL CONTRACTOR AND BUILDING OWNER. THIS CONTRACTOR SHALL SUBMIT REQUESTS, WHERE THEY AFFECT THE OPERATION OF THE BUILDING SYSTEMS, AT LEAST ONE WEEK IN ADVANCE OF ANY REQUIRED SHUTDOWN. THE ACTUAL SHUTDOWN PERIOD SHALL BE AS SHORT AS POSSIBLE AND AT A TIME MUTUALLY AGREEABLE TO THE BUILDING OWNER AND THE CONSTRUCTION MANAGER /GENERAL CONTRACTOR. 7. DRAWINGS ARE DIAGRAMMATIC, THEREFORE DETERMINE EXACT LOCATIONS OF SYSTEMS AND COMPONENTS IN FIELD. 8. ALL WORK SHALL BE COORDINATED WITH ALL TRADES INVOLVED. OFFSETS IN PIPING AND DUCTS INCLUDING DIVIDED DUCTS) AND TRANSITIONS AROUND OBSTRUCTIONS ( ) N _ SHALL BE PROVIDED AT NO ADDITIONAL COST TO THE OWNER. 9. VERIFY ALL EQUIPMENT CONNECTIONS WITH MANUFACTURER'S CERTIFIED DRAWINGS. VERIFY AND PROVIDE DUCT AND /OR PIPE TRANSITIONS TO FURNISHED EQUIPMENT. FIELD VERIFY AND COORDINATE ALL DIMENSIONS BEFORE FABRICATION. 10. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATIONS OF AIR TERMINAL DEVICES. 11. ALL MATERIALS AND EQUIPMENT UNLESS SPECIFICALLY INDICATED AS REUSED, SHALL BE NEW. 12. DUCTWORK SHALL NOT RUN ALONG FULL HEIGHT PARTITIONS. 13. ACCESS PANELS SHALL BE PROVIDED TO ALLOW FOR CLEANING OF COILS AND SERVICING OF DAMPERS, HEATERS, VALVES, AND ALL CONCEALED MECHANICAL EQUIPMENT. 14. THE INSIDE OF ALL DUCTWORK VISIBLE THROUGH A GRILLE OR DIFFUSER SHALL BE PAINTED FLAT BLACK. 15. INSTALL NEW ROOM THERMOSTATS AND SENSORS 4 FEET AFF OR AS DIRECTED OTHERWISE BY ARCHITECT. 16. WHEN SECTION OF DUCTWORK IS NOT LABELED FOR SIZE, THE LARGER SIZE INDICATED ON THE CONNECTED DUCT SHALL PREVAIL. SIZE OF DUCT RUN -OUTS TO DIFFUSER SHALL EQUAL DIFFUSER NECK SIZE. 17. THE FIRE PROOFING OF THE BUILDING STRUCTURE IS NOT TO BE REMOVED FOR THE INSTALLATION OF HANGERS, SUPPORTS, DUCTWORK, ETC. IF FIRE PROOFING IS DAMAGED, IT SHALL BE REPAIRED AT THE EXPENSE OF THE TRADE. M: \2008 \20080075- Fidelity Seattle, WA \Hvac \20080075 H09.01 HVAC SPEC.dwy [30x421 September 23, 2008 - 4:06pm cbutts PART 1 - GENERAL 1. GENERAL PROVISIONS: DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF WORK IN CONTRACT. 2. SCOPE: PERFORM WORK AND PROVIDE NEW MATERIAL AND EQUIPMENT AS SHOWN ON DRAWINGS AND AS SPECIFIED IN THIS SECTION OF THE SPECIFICATIONS. PROVIDE ALL COMPONENTS AND MATERIALS, WHETHER SPECIFICALLY SHOWN OR NOT, THAT ARE NECESSARY TO MAKE THE SYSTEMS COMPLETE AND FULLY OPERATIONAL AS INTENDED IN THE CONSTRUCTION DOCUMENTS. WORK SHALL INCLUDE, BUT NOT BE LIMITED TO: 1) THE DESIGN INTENT AS ILLUSTRATED ON THESE DRAWINGS, 2) ALL TESTING AND CERTIFICATIONS NECESSARY FOR COMPLIANCE INCLUDING ANY REQUIRED REMEDIAL ACTIONS AND RETESTING DUE TO FAILURE. 3. SITE VISIT: VISIT AND CAREFULLY EXAMINE SITE TO IDENTIFY EXISTING CONDITIONS THAT MAY AFFECT WORK OF THIS SECTION BEFORE SUBMITTING BID. NO EXTRA PAYMENT WILL BE ALLOWED FOR ADDITIONAL WORK CAUSED BY UNFAMILIARITY WITH SITE CONDITIONS THAT ARE VISIBLE OR READILY DISCERNED BY AN EXPERIENCED OBSERVER. 4. RELATED WORK: THE FOLLOWING WORK IS NOT INCLUDED IN THIS SECTION AND WILL BE PROVIDED UNDER OTHER SECTIONS: 1) TEMPORARY HEAT FOR USE DURING CONSTRUCTION AND TESTING UNLESS SPECIFICALLY NOTED IN OTHER SPECIFICATION SECTIONS, 2) PAINTING, EXCEPT AS SPECIFIED, 3) ELECTRICAL POWER WIRING TO ALL EQUIPMENT OTHER THAN AUTOMATIC TEMPERATURE CONTROL PANELS AND COMPONENTS, AND 4) DUCT MOUNTED SMOKE DETECTORS SHALL BE FURNISHED BY OTHERS FOR MOUNTING AND WIRING TO THE ATC SYSTEM UNDER THIS SECTION. 5. CODES, STANDARDS, AUTHORITIES AND PERMITS: CODES, LAWS AND ORDINANCES PROVIDE A BASIS FOR THE MINIMUM INSTALLATION CRITERIA. THESE DRAWINGS AND SPECIFICATIONS ILLUSTRATE THE SCOPE REQUIRED FOR THIS PROJECT, WHICH MAY EXCEED MINIMUM CODE, LAW AND STANDARDS CRITERIA. GIVE NOTICES, FILE PLANS, OBTAIN PERMITS AND LICENSES, PAY FEES AND BACKCHARGES AND OBTAIN NECESSARY APPROVALS FROM AUTHORITIES HAVING JURISDICTION AS REQUIRED FOR THE EXECUTION OF ALL WORK ASSOCIATED WITH THIS PROJECT. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST EDITIONS OF: 1) THE STATE BUILDING, ELECTRICAL, MECHANICAL, AND ENERGY CODES, 2) SMACNA, NFPA, ANSI /ASHRAE, ASME, UL, AND NEMA STANDARDS, 3) ALL OTHER APPLICABLE CODES, REGULATIONS, STANDARDS AND LAWS OF LOCAL, STATE AND FEDERAL , E_ ERAL GOVERNMENT AND OTHER AUTHORITIES HAVING JURISDICTION, AND 4) APPLICABLE BASE BUILDING STANDARDS AND SPECIFICATIONS. 6. INTERPRETATIONS OF DOCUMENTS: WHERE DRAWINGS OR SPECIFICATIONS DO NOT COINCIDE WITH MANUFACTURER'S RECOMMENDATIONS, OR ARE UNCLEAR AS TO INTENT, OR REQUIRED MATERIAL QUALITY, ADVISE THE ENGINEER IN WRITING BEFORE PROCEEDING WITH THE WORK. ALL COST FOR REWORK NECESSARY TO RESOLVE DISCREPANCIES SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. 7. REQUESTS FOR INFORMATION: ANY RFI FOR RESOLVING AN APPARENT CONFLICT OR UNCLARITY, OR A REQUEST FOR ADDITIONAL DETAIL, SHALL INCLUDE A SKETCH OR EQUIVALENT DESCRIPTION OF CONTRACTOR'S PROPOSED SOLUTION. 8. SUBMITTALS: PROVIDE SPECIFIED ITEMS AND EQUIPMENT UNLESS "EQUAL" OR "APPROVED EQUAL" IS EXPLICITLY INDICATED ON THE DRAWINGS. DEVIATIONS TO SPECIFIED ITEMS SHALL BE AT THE SOLE RISK OF THE CONTRACTOR, WHO SHALL BE RESPONSIBLE FOR ALL ASSOCIATED CHANGES TO THIS AND OTHER TRADES. REVIEW OF THE SHOP DRAWINGS BY THE ENGINEER SHALL NOT ABSOLVE THE CONTRACTOR FROM MEETING THE FULL DESIGN INTENT OF THE ASSOCIATED SYSTEM(S). SUBMITTALS SHALL INDICATE PRIOR REVIEW AND APPROVAL BY THE RESPONSIBLE CONTRACTOR. SUBMIT FOR REVIEW (6) SETS OF MANUFACTURER'S PRODUCT DATA FOR THE FOLLOWING ITEMS: 1) AIR DISTRIBUTION LAYOUT DRAWINGS AND DETAILS, 2) PIPING DISTRIBUTION LAYOUT DRAWINGS, COMPONENTS, AND DETAILS, 3) ALL EQUIPMENT, 4) CONTROL SCHEMATICS, COMPONENTS, AND SEQUENCES, INCLUDING TIE -IN TO THE EXISTING ROOFTOP UNIT CONTROL, 5) BALANCING REPORTS, 6) ALL TEST REPORTS, AND 7) ALL CERTIFICATES. ALLOW ENGINEER A MINIMUM OF 10 WORKING DAYS FOR PROCESSING AND REVIEW OF EACH SUBMISSION. 9. OPERATION AND MAINTENANCE DATA: SUBMIT (3) SETS OF OPERATING AND MAINTENANCE MANUALS PRIOR TO THE COMPLETION OF THE PROJECT. PROVIDE ON -SITE DEMONSTRATION OF ALL SYSTEMS TO OWNER AFTER SYSTEMS ARE FULLY OPERATIONAL. O&M MANUALS SHALL INCLUDE ALL COMPONENTS (DIFFUSERS, ETC.) AS WELL AS SYSTEM DESCRIPTIONS OF ALL SYSTEMS WITH FLOW DIAGRAMS, WIRING DIAGRAMS, WRITTEN WARRANTEES, RECOMMENDED SPARE PARTS AND ROUTINE MAINTENANCE REQUIREMENTS WITH RECOMMENDED INTERVALS FOR ALL MOVING EQUIPMENT AND CONTROLS. 10. RECORD DRAWINGS: CAD RECORD DRAWING FILES SHALL BE SUBMITTED AT THE COMPLETION OF THE PROJECT SHOWING THE "AS- BUILT CONDITION INCLUDING WORK INSTALLED AND ALL MODIFICATIONS OR ADDITIONS TO ORIGINAL DESIGN. OBTAIN THE AUTOCAD FILES FOR PREPARATION OF AS -BUILT DRAWINGS FROM THE ARCHITECT. THE ARCHITECT AND ENGINEER ARE NOT GRANTING ANY OWNERSHIP OR PROPERTY INTEREST IN THE CAD DRAWINGS BY THE DELIVERY OF THE CAD FILES. THE USE OF THE CAD FILES AND DRAWINGS ARE LIMITED FOR THE SOLE PURPOSE OF ASSISTING IN THE CONTRACTOR'S PERFORMANCE IN ITS CONTRACTUAL OBLIGATIONS WITH RESPECT TO THIS PROJECT. ANY REUSE AND /OR OTHER USE BY THE CONTRACTOR WILL BE AT THE CONTRACTOR'S SOLE RISK AND WITHOUT LIABILITY TO THE ARCHITECT AND ENGINEER. 11. WARRANTIES: WARRANTY INSTALLATION IN WRITING FOR ONE YEAR FROM DATE OF OWNER'S ACCEPTANCE OF CERTIFICATE OF SUBSTANTIAL COMPLETION. WHERE INDIVIDUAL EQUIPMENT SECTIONS SPECIFY LONGER WARRANTEES, PROVIDE THE LONGER WARRANTEE. REPAIR, REPLACE OR PROVIDE TEMPORARY ACCOMMODATIONS FOR DEFECTIVE MATERIALS, EQUIPMENT, WORKMANSHIP AND INSTALLATION THAT DEVELOP WITHIN 24 HOURS OF NOTIFICATION. WARRANTY SHALL INCLUDE A CONTACT PERSON (NAME AND 24 HOUR TELEPHONE NUMBER) FOR SERVICE REQUESTS. CORRECT DAMAGE CAUSED WHILE MAKING NECESSARY REPAIRS AND REPLACEMENTS UNDER WARRANTY PERIOD AT NO ADDITIONAL COST. 12. COORDINATION: CONFER WITH ALL OTHER TRADES RELATIVE TO LOCATION OF ALL APPARATUS AND EQUIPMENT TO BE INSTALLED AND SELECT LOCATIONS SO AS NOT TO CONFLICT WITH OR HINDER THE PROGRESS OF THE WORK OF OTHER SECTIONS. WORK INSTALLED THAT CREATES INTERFERENCE OR RESTRICTS ACCESS REQUIRED BY CODE (INCLUDING CLEARANCES TO ELECTRICAL COMPONENTS) OR TO CONDUCT MAINTENANCE AND /OR ADJUSTMENTS SHALL BE MODIFIED AT NO ADDITIONAL COST TO THE OWNER. 13. SUPPORTS: INCLUDE ALL STRUCTURAL STEEL SUPPORTS, HANGER BRACKETS, ETC., REQUIRED FOR THE EXECUTION OF THE WORK OF THIS SECTION. THE WELDS AND EDGES OF ALL BRACKETS SHALL BE FILED OR GROUND SMOOTH FOR PAINTING. HANGERS SHALL BE STEEL ANGLE IRON, CHANNEL OR STEEL ROD USED WITH APPROVED CLAMPS, INSERTS, ETC. ALL HANGERS SHALL BE GALVANIZED OR PAINTED WITH TWO COATS OF RUSTOLEUM PAINT BEFORE INSTALLATION. APPLY TOUCH -UP PAINT (ZINC GALVANIZING FOR GALVANIZED STEEL) AFTER INSTALLATION. 14. CUTTING AND PATCHING: INCLUDE ALL CORING, CUTTING, PATCHING AND FIREPROOFING NECESSARY FOR THE EXECUTION OF THE WORK OF THIS SECTION. STRUCTURAL ELEMENTS SHALL NOT BE CUT WITHOUT WRITTEN APPROVAL OF THE ARCHITECT. REPAIR AND PATCH AROUND THE WORK SPECIFIED HEREIN TO MATCH THE EXISTING ADJACENT SURFACES TO THE SATISFACTION OF THE ARCHITECT. FILL AND PATCH ALL OPENINGS OR HOLES LEFT IN THE EXISTING STRUCTURES BY THE REMOVAL OF EXISTING EQUIPMENT THAT IS PART OF THIS SECTION OF THE SPECIFICATIONS. PATCH AND SEAL ALL EXISTING OPENINGS IN DUCTWORK AND PIPING NOT UTILIZED FOR NEW LAYOUT. PROVIDE FIRE STOPPING TO MAINTAIN THE FIRE RATING OF THE FIRE RESISTANCE -RATED ASSEMBLY. ALL PENETRATIONS AND ASSOCIATED FIRE STOPPING SHALL BE INSTALLED IN ACCORDANCE WITH THE FIRE STOPPING MANUFACTURER'S LISTED INSTALLATION DETAILS AND BE LISTED BY UL OR FM. 15. HOISTING, SCAFFOLDING AND PLANKING: INCLUDE THE FURNISHING, SET -UP AND MAINTENANCE OF ALL HOISTING MACHINERY, CRANES, SCAFFOLDS, STAGING AND PLANKING AS REQUIRED FOR THE EXECUTION OF WORK FOR THIS SECTION. 16. SAFETY PRECAUTIONS: LIFE SAFETY AND ACCIDENT PREVENTION SHALL BE A PRIMARY CONSIDERATION. COMPLY WITH ALL OF THE SAFETY REQUIREMENTS OF THE OWNER AND OSHA THROUGHOUT THE ENTIRE CONSTRUCTION PERIOD OF THE PROJECT. FURNISH, PLACE AND MAINTAIN PROPER GUARDS AND ANY OTHER NECESSARY CONSTRUCTION REQUIRED TO SECURE SAFETY OF LIFE AND PROPERTY. 17. ACCESSIBILITY: ALL WORK PROVIDED UNDER THIS SECTION OF THE SPECIFICATION SHALL BE INSTALLED SO THAT PARTS REQUIRING PERIODIC INSPECTION, MAINTENANCE AND REPAIR ARE READILY ACCESSIBLE. WORK OF THIS TRADE SHALL NOT INFRINGE UPON CLEARANCES REQUIRED BY EQUIPMENT OF OTHER TRADES. 18. PROTECTION OF WORK AND PROPERTY: THIS CONTRACTOR SHALL BE RESPONSIBLE FOR THE CARE AND PROTECTION OF ALL WORK INCLUDED UNDER THIS SECTION UNTIL THE COMPLETION AND FINAL ACCEPTANCE OF THIS PROJECT. PROTECT ALL EQUIPMENT AND MATERIALS FROM DAMAGE FROM ALL CAUSES INCLUDING, BUT NOT LIMITED TO, FIRE, VANDALISM AND THEFT. ALL MATERIALS AND EQUIPMENT DAMAGED OR STOLEN SHALL BE REPAIRED OR REPLACED WITH EQUAL MATERIAL OR EQUIPMENT AT NO ADDITIONAL COST TO THE OWNER. PROTECT ALL EQUIPMENT, OUTLETS AND OPENINGS, AND ROOF PENETRATIONS WITH TEMPORARY PLUGS, CAPS AND COVERS. PROTECT WORK AND MATERIALS OF OTHER TRADES FROM DAMAGE THAT MIGHT BE CAUSED BY WORK OR WORKMEN UNDER THIS SECTION AND MAKE GOOD DAMAGE THUS CAUSED. DAMAGED MATERIALS ARE TO BE REMOVED FROM THE SITE; NO SITE STORAGE OF DAMAGED MATERIALS WILL BE ALLOWED. ANY DAMAGE TO EXISTING SYSTEMS AND EQUIPMENT CAUSED BY THIS CONTRACTOR DURING INSTALLATION SHALL BE REPAIRED AND /OR REPLACED AT THIS CONTRACTOR'S EXPENSE TO THE COMPLETE SATISFACTION OF THE BUILDING OWNER. 19. SEISMIC RESTRAINT REQUIREMENTS: PROVIDE SEISMIC RESTRAINTS AS REQUIRED IN ACCORDANCE WITH THE STATE BUILDING CODE. A REGISTERED PROFESSIONAL STRUCTURAL ENGINEER, LICENSED IN THE APPLICABLE STATE FOR THE PROJECT LOCATION, SHALL PREPARE THE SEISMIC RESTRAINT DESIGN AND CERTIFY THAT THE DESIGN IS IN COMPLIANCE WITH THE STATE BUILDING CODE REQUIREMENTS. 20. PROJECT CLOSEOUT: A CERTIFICATE OF COMPLETION SHALL BE ISSUED BY THE CONTRACTOR INDICATING THAT THE INSTALLATION IS IN CONFORMANCE WITH W TH THE CONSTRUCTION DOCUMENTS AND ALL APPLICABLE LOCAL, STATE AND FEDERAL STATUTES AND CODES. ALL SUBMITTALS, AS- BUILTS, O &M MANUALS, AND BALANCING REPORTS ARE TO BE PROVIDED, FOR ENGINEER'S REVIEW, PRIOR TO REQUEST FOR COMPLETION CERTIFICATES. IN ADDITION, AND ALSO PRIOR TO REQUEST FOR COMPLETION CERTIFICATES, ALL PUNCH LIST ITEMS MUST BE COMPLETED TO THE SATISFACTION OF THE ENGINEER. THE CONTRACTOR MUST VERIFY THAT ALL SEQUENCES OF OPERATIONS AND CONTROLS HAVE BEEN INCORPORATED AND ALL SYSTEMS AND EQUIPMENT ARE WORKING PER THE SPECIFIED SEQUENCES OF OPERATIONS. A BLANK CONTRACTOR'S CERTIFICATE FORM CAN BE FURNISHED BY RDK ENGINEERS UPON REQUEST. FINAL INSPECTION BY THE ENGINEER SHALL BE CONDUCTED AFTER RECEIPT OF THE CERTIFICATE OF COMPLETION. PREMATURE REQUESTS FOR FINAL INSPECTIONS THAT REQUIRE REINSPECTION OF DEFICIENT ITEMS WILL RESULT IN BACK CHARGES OF THE COSTS ASSOCIATED WITH THE REINSPECTION. PART 2 - PRODUCTS 1. DUCTWORK: MATERIAL, CONSTRUCTION, AND INSTALLATION SHALL MEET REQUIREMENTS OF MOST RECENT EDITIONS OF SMACNA HVAC DUCT CONSTRUCTION STANDARDS, EXCEPT FOR MORE STRINGENT REQUIREMENTS SPECIFIED OR SHOWN ON DRAWINGS. MEDIUM PRESSURE DUCTWORK BETWEEN FANS AND VOLUME BOXES SHALL BE BUILT TO 4" PRESSURE CLASS WITH SEAL CLASS A. UNLESS SPECIFIED OTHERWISE, ALL OTHER DUCTWORK SHALL BE BUILT TO 2" PRESSURE CLASS WITH SEAL CLASS B. PROVIDE FLEXIBLE CONNECTION ON ALL DUCTS CONNECTING TO FANS AND ROTATING EQUIPMENT. ALL DUCTS SHALL BE GROUNDED ACROSS FLEXIBLE CONNECTION WITH FLEXIBLE COPPER GROUNDING STRAPS. MAXIMUM LENGTH OF FLEXIBLE RUN -OUT TO DIFFUSERS SHALL BE 6 FEET. FOR LONGER RUN -OUTS, ADD RIGID DUCT. DUCTS SHALL BE CONSTRUCTED OF HOT DIPPED GALVANIZED STEEL UNLESS OTHERWISE NOTED. 2. VOLUME DAMPERS: PROVIDE MANUAL ADJUSTABLE VOLUME DAMPERS, WITH EXTENDED MOUNT, INDICATING AND LOCKING QUADRANTS ON EACH TAKE -OFF TO REGISTER, GRILLE, OR DIFFUSER (NOT ALL MAY BE SHOWN ON DRAWINGS). PROVIDE REMOTE BALANCING VOLUME DAMPERS FOR VOLUME DAMPERS NOT ACCESSIBLE VIA CEILING TILE. ACCEPTABLE MANUFACTURERS SHALL BE YOUNG REGULATORS OR APPROVED EQUAL. 3. DIFFUSERS, REGISTERS, AND GRILLES: PROVIDE DIFFUSERS, REGISTERS AND GRILLES FOR SUPPLY, RETURN, AND EXHAUST OUTLETS, OF SIZE, TYPE, AND DESIGN SHOWN ON DRAWINGS. DIFFUSER SIZES SHOWN ARE NECK SIZES; REGISTER AND GRILLE SIZE ARE NOMINAL. ACCEPTABLE MANUFACTURERS: TITUS OR KRUEGER AS PER FIDELITY STANDARDS. SOUND PRESSURE LEVELS ARE NOT TO EXCEED NC 30. 4. ACOUSTICAL SOUND LINING: MATERIALS AND INSTALLATION SHALL MEET THE FOLLOWING STANDARDS, AS APPLICABLE: NFPA -90A, UL723, NFPA -255; SMACNA DUCT LINER APPLICATIONS STANDARD; SMACNA MECHANICAL FASTENERS STANDARD; ADHESIVE AND SEALANT COUNCIL: ADHESIVES STANDARD FOR DUCT LINER - ASC- A- 7001A; ASTM E -84 FIRE HAZARD CLASSIFICATIONS OF 25 FLAME SPREAD, 50 SMOKE DEVELOPED, AND 50 FUEL CONTRIBUTED. INTERNAL AIRFLOW DIMENSIONS ARE SHOWN FOR DUCTS, CONTRACTOR SHALL INCREASE DUCT SIZE FOR LINING. PROVIDE MINIMUM 1" THICK ACOUSTICAL LINING. TO MEET THE ENERGY CODE REQUIREMENTS FOR R5 INSULATION FOR SUPPLY AND RETURN DUCTWORK IN PLENUMS, PROVIDE EITHER 1 -1/2" THICK LINING OR 1" THICK LINING WITH MINIMUM 1/2" THICK EXTERIOR INSULATION. SEAL ALL JOINTS WITH MANUFACTURER APPROVED MASTIC. USE SHEET METAL NOSING AT ALL RAW EDGES. LINING SHALL BE BY CERTAIN-TEED, KNAUF, OWENS CORNING, OR MANVILLE FOR THE FOLLOWING DUCTWORK: 1) SUPPLY, RETURN, AND EXHAUST AIR DUCTWORK, INCLUDING PLENUMS, FOR MINIMUM OF 20 FEET FROM ROOFTOP UNITS AND EXHAUST FANS, 2) ALL LOW PRESSURE DUCTWORK DOWNSTREAM OF FAN BOXES, 3) TRANSFER DUCTS. 5. DUCT INSULATION (EXTERNAL): INSULATION SHALL BE CERTAIN-TEED, KNAUF, MANVILLE, OR OWENS CORNING. MATERIALS SHALL MEET REQUIREMENTS OF ADHESIVE AND SEALANT COUNCIL STANDARDS AND SMACNA. DUCTWORK THAT IS LINED DOES NOT NEED EXTERNAL INSULATION EXCEPT FOR SUPPLY AND RETURN DUCTWORK LINED WITH ONLY 1" THICK LINING LOCATED IN PLENUMS. TO MEET THE ENERGY CODE R5 REQUIREMENT, ADD A MINIMUM 1/2" THICK EXTERIOR INSULATION TO THESE LINED DUCTS. INSULATE ALL SUPPLY AIR DUCTS AND PLENUMS. EXPOSED INSULATION SHALL BE RIGID FIBERGLASS INSULATION WITH ALUMINUM VAPOR BARRIER. 6. PIPE INSULATION: INSULATION SHALL BE FIBROUS GLASS INSULATION WITH FACTORY- APPLIED FIRE RETARDANT VAPOR BARRIER JACKET WITH K FACTOR OF AT LEAST 0.23 AT 75 DEG. F MEAN TEMPERATURE BY OWENS CORNING, CERTAIN -TEED, MANVILLE, OR KNAUF. ASTM E -84 FIRE HAZARD RATINGS SHALL BE 25 FLAME SPREAD, 50 SMOKE DEVELOPED AND 50 FUEL CONTRIBUTED. CONDENSATE DRAIN LINES, AND OUTDOOR LIQUID LINES SHALL BE INSULATED WITH 3/8" THICK RIGID CLOSED CELL FOAM INSULATION. 7. PIPE HANGERS AND SUPPORTS: PROVIDE PIPE STANDS, SUPPORTS, HANGERS, AND OTHER SUPPORTING APPLIANCES AS NECESSARY TO SUPPORT WORK REQUIRED BY CONTRACT DOCUMENTS. SPACING OF HANGERS SHALL BE INSTRUCTED IN ACCORDANCE WITH APPLICABLE BUILDING AND MECHANICAL CODES. SIZE OF HANGERS SHALL INCLUDE THE PIPE INSULATION WITH SHIELD. 8. VARIABLE VOLUME FAN BOXES: PROVIDE BOXES BY JCI, NAILOR, OR TITUS. ALL BOXES SHALL HAVE PRESSURE INDEPENDENT CONTROLLERS COMPATIBLE WITH THE CONTROL SYSTEM AND MULTI -POINT FLOW SENSORS. UNITS SHALL NOT DEVIATE FROM SET MINIMUM OR MAXIMUM FLOW SETTINGS BY MORE THAN 10 %, REGARDLESS OF INLET ANGLE. INLET VELOCITIES SHALL NOT EXCEED 2000 FPM. SOUND DATA SHALL BE CERTIFIED IN ACCORDANCE WITH ADC STANDARD 1062. BOX AIR LEAKAGE SHALL NOT BE MORE THAN 2% OF MAXIMUM AIRFLOW. PROVIDE INTEGRAL REHEAT COILS OF TYPE AND CAPACITY INDICATED ON DRAWINGS. 9. VIBRATION ISOLATION: PROVIDE VIBRATION ISOLATION FOR EACH PIECE OF ROTATING OR PISTON DRIVEN HVAC EQUIPMENT SHOWN ON THE DRAWINGS. ISOLATION MAY BE INTERNAL OR EXTERNAL TO THE EQUIPMENT AND SHALL PROVIDE AT LEAST 90% ISOLATION EFFICIENCY. ISOLATE THE FIRST THREE PIPE HANGER LOCATIONS FROM EQUIPMENT WITH 1" DEFLECTION COMBINATION SPRING AND NEOPRENE, NAI (NOVIA ASSOCIATION) MODEL "SNH" OR EQUIVALENT BY MASON INDUSTRIES OR KINETICS. INSTALLATION PRACTICES SHALL BE IN STRICT ACCORDANCE WITH THE RECOMMENDATIONS OF THE VIBRATION ISOLATION MANUFACTURER. 10. CABINET HEATERS AND UNIT HEATERS: PROVIDE CABINET UNIT HEATERS AND UNIT HEATERS OF THE TYPE AND CAPACITY SHOWN ON THE DRAWINGS. ACCEPTABLE MANUFACTURERS ARE Q -MARK, TRANE, MCQUAY, AAF, BRASCH, OR STERLING. PROVIDE THERMOSTATS AND ALL OPERATING AND SAFETY CONTROLS. 11. AUTOMATIC TEMPERATURE CONTROLS: PROVIDE COMPLETE SYSTEM OF AUTOMATIC TEMPERATURE CONTROLS BY JOHNSON, ANDOVER, OR SIEMENS. CONTROL SYSTEM SHALL BE CAPABLE OF PERFORMING ALL SEQUENCES OF OPERATION SHOWN ON THE DRAWINGS OR DESCRIBED IN THESE SPECIFICATIONS. INDIVIDUAL CONTROL COMPONENTS MAY NOT BE SHOWN ON CONTRACT DOCUMENTS, BUT ATC CONTRACTOR SHALL SUPPLY ALL COMPONENTS, CONTROL WIRING (INCLUDING POWER WIRING TO ALL PANELS, CONTROLLERS, TRANSFORMERS, ACTUATORS, ETC.), NECESSARY FOR A COMPLETE OPERABLE SYSTEM. COORDINATE WITH ELECTRICAL CONTRACTOR FOR LOCATION OF LINE VOLTAGE JUNCTION BOX IN EACH MECHANICAL AREA. ATC CONTRACTOR SHALL EXTEND WIRING FROM THESE BOX(ES) TO ALL CONTROL COMPONENTS AND SHALL BE RESPONSIBLE FOR ALL SYSTEM COMPONENTS, WHETHER HE SUBCONTRACTS ELECTRICAL AND OTHER WORK OR NOT. ALL WIRING SHALL COMPLY WITH THE REQUIREMENTS OF THE ELECTRICAL SECTION OF THESE SPECIFICATIONS. WIRING BETWEEN FIRE ALARM SYSTEM AND TEMPERATURE CONTROL SYSTEM, EXCEPT FOR DUCT MOUNTED SMOKE DETECTORS (FURNISHED BY THE ELECTRICAL CONTRACTOR), SHALL BE BY THE ATC CONTRACTOR. PART 3 - EXECUTION 1. INSTALLATION OF EQUIPMENT: INSTALL ALL ITEMS SPECIFIED UNDER PART 2 - PRODUCTS, ACCORDING TO THE MANUFACTURER'S REQUIREMENTS, SHOP DRAWINGS, AND DETAILS AS SHOWN ON THE DRAWINGS AND AS SPECIFIED. INSTALL ALL WORK SO THAT PARTS REQUIRING INSPECTION, REPLACEMENT, MAINTENANCE AND REPAIR SHALL BE READILY ACCESSIBLE. MINOR DEVIATIONS FROM THE DRAWINGS MAY BE MADE TO ACCOMPLISH THIS, BUT ANY SUBSTANTIAL CHANGE SHALL NOT BE MADE WITHOUT PRIOR WRITTEN OWNER APPROVAL. 2. IDENTIFICATION: ALL EQUIPMENT, PIPING, AND DUCTWORK PROVIDED UNDER THIS SECTION OF THE SPECIFICATIONS SHALL BE MARKED FOR EASE OF IDENTIFICATION PER OWNER'S OR INDUSTRY STANDARDS. 3. CLEANING: DUCTS SHALL BE THOROUGHLY CLEANED SO THAT NO DIRT OR DUST SHALL BE DISCHARGED FROM DIFFUSERS, REGISTERS, OR GRILLES, WHEN SYSTEM IS OPERATED. AFTER COMPLETION OF PROJECT, CLEAN EXTERIOR SURFACES OF ALL EQUIPMENT INCLUDED IN THIS SECTION, INCLUDING REMOVAL OF CONCRETE RESIDUE. AFTER COMPLETION OF PROJECT, REMOVE ALL CONSTRUCTION DEBRIS, TEMPORARY FACILITIES AND EQUIPMENT FROM WORK AREA. CLEAN WORK AREA TO PERMIT OCCUPATION. 4. TESTING AND INSPECTION: PROVIDE QUALIFIED PERSONNEL, EQUIPMENT, APPARATUS, AND SERVICES FOR TESTING AND INSPECTION OF MECHANICAL SYSTEMS. DO NOT COVER OR CONCEAL WORK BEFORE TESTING AND INSPECTION AND OBTAINING APPROVAL. REPORT ON INDUSTRY STANDARD REPORTING FORMS, SUBMITTED FOR APPROVAL IN ADVANCE. SUBMIT SIX COPIES OF TESTING REPORTS FOR APPROVAL. CONTRACTOR SHALL FURNISH ALL TEST MEDIUMS AND DISPOSE OF ALL TEST MEDIUMS AT AN APPROVED OFF SITE LOCATION AFTER TESTING IS COMPLETE. 5. START UP AND BALANCING: PROVIDE NEBB OR AABC CERTIFIED PERSONNEL, EQUIPMENT, APPARATUS, AND SERVICES FOR START-UP AND BALANCING OF MECHANICAL SYSTEMS TO PERFORMANCE DATA SHOWN IN SCHEDULES AND ON DRAWINGS, AS SPECIFIED, AND AS REQUIRED BY CODES, STANDARDS, REGULATIONS, AND AUTHORITIES HAVING JURISDICTION INCLUDING CITY INSPECTORS. AIR FLOWS SHALL BE BALANCED TO +/- 10% OF DESIGN. LEAKS, DAMAGE, AND DEFECTS DISCOVERED OR RESULTING FROM START -UP AND BALANCING SHALL BE REPAIRED OR REPLACED TO LIKE -NEW CONDITION WITH ACCEPTABLE MATERIALS. TESTS SHALL BE CONTINUED UNTIL SYSTEM OPERATES WITHOUT ADJUSTMENTS OR REPAIRS. REPORT DATA ON INDUSTRY STANDARD NEBB OR AABC REPORTING FORMS. AIR TERMINAL UNIT DATA SHALL INCLUDE ALL PRIMARY AIR FLOWS (MAXIMUM, MINIMUM AND HEATING). FAN POWERED BOXES SHALL INCLUDE ALL PRIMARY AIR FLOWS, FAN AIRFLOW, AND MOTOR DATA. SUBMIT SIX COPIES OF START -UP AND BALANCING REPORTS TO ARCHITECT FOR APPROVAL. HVAC SPECIFICATIONS MO8 io KEN/ ItVVED FOR CODE COMPLIANCE. APPROVE OCI 0 9 2008 City ©f rUI Nt ILDIN 8 h Seattle out � eatt e a c h 304 Strander Blvd. Seattle, WA 98188 Gensler ENGINEERS Issue 01 Seal /Signature Project Name Fidelity Investor Center ® SEATTLE BRANCH Project Number 20080075 CAD File Name 20080075J-109.01 Description H09.01 Q2006 Gensler F / A_I VESTMENTS Date & Issue Description By Check 07/02/08 KJL TPW ISSUED FOR CONSTRUCTION HVAC SPECIFICATIONS AND NOTES Scale NTS 133 Federal Street 5th Floor Boston MA 02110 Telephone 2� 2,4400 617. X Facsimile 617.292.4401 Richard D. Kimball Company, Inc Seaport Center 70 Fargo Street Suite 801 Boston, MA 02210 -1964 T 617 -345 -9885 F 617 - 345 -4226 W www.rdkengineers.com R CEI 'F SEP 3 0 2.000 PERMIT CENTE-.