Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M08-259 - COMMITTEE FOR A BETTER KING COUNTY
COMMITTEE FOR A BETTER KING COUNTY 3415 S 116 ST SUITE 109 M08 -259 Parcel No.: 1023049043 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: 3415 S 116 ST TUKW Contact Person: Name: TERRY COURSE Address: 899 W MAIN , AUBURN WA Contractor: Name: SEATTLE MECHANICAL Address: 5805 -A GLENWOOD AV , EVEREIT WA Contractor License No: SEATTM *932PP DESCRIPTION OF WORK: PROVIDE AND INSTALL NEW 4 TON GAS /ELECTRIC ROOF TOP UNIT, WITH NEW DUCTWORK AND DIFFUSERS Value of Mechanical: $12,000.00 Type of Fire Protection: COMMITTEE FOR A BETTER KING COUNTY 3415 S 116 ST - SUITE 109 , TUKWILA WA TTA/E PROPERTY TAX DEPT 207 PO BOX 4900 , SCOTTSDALE AZ Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial CitAf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT EQUIPMENT TYPE AND OUANTITY 0 0 0 0 0 0 1 0 0 0 0 0 0 0 * *continued on next page ** I Permit Number: Issue Date: Permit Expires On: Phone: Phone: 253 - 939 -9595 Phone: 425 231 -3123 Expiration Date: 10/17/2009 M08 -259 12/03/2008 06/01/2009 Fees Collected: $305.00 International Mechanical Code Edition: 2006 Boiler Compressor: 0-3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment doc: IMC-10/06 M08 -259 Printed: 12 -03 -2008 Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie Signature. Print Name: This permit shall or abandoned for • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us x- wit • Permit Number: M08 -259 Issue Date: 12/03/2008 Permit Expires On: 06/01/2009 Date: r; , 'V °1 ed thi permit and know the same to be true and correct. All provisions of law and ordinances , whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or authorized to sign and obtain this mechanical permit. Date: Veg come null an oid if the work is not commenced within 180 days from the date of issuance, or if the work is suspended eriod of 180 days from the last inspection. doc: IMC-10/06 M08 -259 Printed: 12 -03 -2008 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS • Parcel No.: 1023049043 Permit Number: M08 -259 Address: 3415 S 116 ST TUKW Status: ISSUED Suite No: Applied Date: 10/29/2008 Tenant: COMMITTEE FOR A BETTER KING COUNTY Issue Date: 12/03/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Cond - 10/06 * * continued on next page ** M08 -259 Printed: 12 -03 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. doc: Cond -10/06 Date: ) /( CJ M08 -259 Printed: 12 -03 -2008 SITE LOCATI ;A:. ,= 7X764W t' € lf4.; �d: =.H+n n:l - �i✓ . Site Address: 3415 S 116TH . Tenant Name: COMMITTEE FOR A BETTER KING CO. Property Owners Name: RREEF PROPERTY MGMT. Mailing Address: 12720 GATEWAY DRIVE, SUITE 200 TUKWILA WA. 98168 Zip Name: TERRY COURSE • CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 ht tp: / /www. ci. tukwila. wa. us Mailing Address: 899 west main Auburn wa. E -Mail Address: seattlemechanical@msn.com Contact Person: E -Mail Address: Contractor Registration Number: 14: •X'y4f.Vt _ :Y {� {P�,'T.'.y .�ifiY.Y t F. or.ofce. Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: 000480003 10)-30 to 1 i 3 Suite Number: 109 Floor: New Tenant: © Yes ❑ .. No • City State 11 �}- ..a ' w+d �T ?CSC. .ell. N t"J+•t :. „3.a,,t,nar 'A"y,::a -�' 'ACT P ERSON who do we contact whenyour_ permit is ready,.to be Issued g4P-igatSOPR:�,, ."_` .W., '�4'_'E.'e`,:f t i i[<�,?q,,.�i r"� •'V 'Al§ x4:41 .a 1 . y W : W :TV rte.' ,.;- tY Y�+.�.. t� 'idz .�•... �. �::. �t� Day Telephone: City State Fax Number: 253- 939 -9260 GE NERAL CQNTRACTOR (Contr=actor Information for Mech nical'(pg 4j for, Plumbing nd ?Gas Piping (pg Company Name: Mailing Address: City Day Telephone: Fax Number: Expiration Date: State vy�" G k ci•'ric4vrx i. .' k: A . t >E7 t� M�+ t v.? ��:� ARCHI TECT;OF RECO Alliplans must be''wet stamped•byoArcbkect of Recc ord t$ t,, r. �" i' ♦ ' t�• '.'.t' •;' : °z�4'i d7 v'cg� frr�"u.' •r�!!:. +.- - t; ,,s17 e Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: State State Zip Zip Zip � K .�xrTg �:' k= �EZiE?i;'.<:k �` L."EA'da � "` ' '%,`nb.- �' ^ew:: ' ' .3 ->+ : k^' n'"i `.; : �? E RD - ` ;All plans :must be wet stamped°by of Record ?aat' x ° a�h�` � t 4,? a kdE�, n w w x s iia gnA3t 2 1'a47tSW ct.`":a•. Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Q:\ApplicationsTFonna- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Zip Page 1 of 6 Unit Type: Qty • Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM 1 Incinerator — Comm/Ind Contact Person: TERRY COURSE rM CHXN tc- Atitki iNif RMA`TI 206 =431 3670 1= igi S�a ; �e?i3+: Asti: +, '. , +�z'. .eS� J- ` '. ° ,•✓ —' i :sLv'% = r �*$ 4 M.w. d ` FS MECHANICAL CONTRACTOR INFORMATION Company Name: IECS INC Mailing Address: 899 WEST MAIN AUBURN WA. 98001 Zip E-Mail Address: SEATTLE MEHCANICAL Contractor Registration Number: IECS * * * 044QL Valuation of Mechanical work (contractor's bid price): $ 12,000 Scope of Work (please provide detailed information): PROVIDE AND INSTALL NEW 4 TON GAS /ELECTRIC ROOF TOP UNIT. WITH NEW DUCTWORK AND DIFFUSERS. Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... [ Replacement .... ❑ Fuel Type: Electric ❑ Gas....® Other: Indicate type of mechanical work being installed and the quantity below: Q:Wpplications\Ponns- Applications On Line\3 -2006 - Permit Application.doc Revised: 9-2006 bh City State Day Telephone: 253 939 - 9495 Fax Number: 253 939 - 9260 Expiration Date: 11 /13 / 08 Page 4 of 6 BUILDING 0 Signature: Print Name: Mailing Address: , - �+� -, r , ,xi�+� is, i .;' JF �57ta.�'; . r••�:' Z {4'tv� °Cr' +•c- ,. a RNIIT APPLICATIONaNOTESt��Applica> ile � to � all�pelrmltssinithlstappLcation 3* r tac c a' '�" sn z tT z -r �*�.�3:ic4r�• .rf`.r'�• {'„�..:'�2h�t, Ku��i!'£ � ��-.�� r.,�.ri: t`.r:"s':rg •cxkow ~k *.`z s3rr >_mtiS,. Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. ORIZED AGENT: ,L)/ ►ki g`1 �✓-��' /G,f Date: 1/ ? 2dCS/ Day Telephone: u (fr. U"— City S tate I Date Application Accepted: Date Application Expires: Staff Initials: i Q:Wpplications'Fonns- Applications On Line\3.2006 • Permit Application.doc Revised: 9.2006 bh Page 6 of 6 Receipt No.: R08 -03642 Initials: User ID: Payee: WER 1655 IECS ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 42823 305.00 RECEIPT Parcel No.: 1023049043 Permit Number: M08 -259 Address: 3415 S 116 ST TUKW Status: PENDING Suite No: Applied Date: 10/29/2008 Applicant: COMMITTEE FOR A BETTER KING COUNTY Issue Date: Account Code Current Pmts 000.322.102.00.0 244.00 000/345.830 61.00 Total: $305.00 • Payment Amount: $305.00 Payment Date: 10/29/2008 11:33 AM Balance: $0.00 1 af 2- doc: Receiot -06 Printed: 10 -29 -2008 Projec t .0 imiat: tile Bek-eflq T of Inspecti . Address: i -i. Date Called: Special Instructions: Date Wanted: ' Z '4..• D a/ a 4p.m. Requester: Phone No: Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 AA i* , PERMIT NO. (206)431 -3670 Corrections required prior to approval. COMMENTS: I f)C ILA i a Le` PiA`. p c @AY Inspectc , , Date: / ? EJ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: i�; COMMENTS: • i Add i 5 i g- E 0 1 6 2e P.(- Pf /t r l ` e t IA Ali e 1 AAke. r I� r r4 Date Wanted: � � � a .m1 /Z O p.m Requester: 1 r C /)#' .e. • Ca I2 j f iv - r t A d Project: Type of In Rectio Add i 5 // 6 6--- Date Calledr ,'�� 4 Lie Special Instructions: : 00.„0 „. 1°.°..----- Date Wanted: � � � a .m1 /Z O p.m Requester: P hone ii0 2-.C-C —0045 INSPECTION NO. Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 60.00 REINSPECTION FEE REQ( IRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: M O' -25 PERMIT NO. (206)431 -3670 Date: C - -Or Corrections required prior to approval. CT ENGINEERING INC Struotural Engineers 180 Nickerson Street Suite 302 Seattle, WA 98109 208.285.4512 (V) 208.285.0818 (F) NEW MECH UNIT EXPIRES 5/12/09 J J U' #12 x 21/2" WOOD SCREW @ 24 "OC 3/4"0 LAG SCREW ® 24 "0C PENETRATE BEAM BELOW 4" MIN 4x6 EXISTING 4X16 @ 8' OC PARTIAL FRAMING PLAN NEW HVAC UNIT WITH CURB 520 # MAX NEW 4X8 AT SIDE W /LUS46 HANGER N TS EXISTING PURLIN ® 8' OC EXISTING GLB SECTION A 257 KtV1tWt) pp CC pp NCE MPPROED- ?„.. NOV 14 2008 Of Tukwila B I1.DIN DMSI I N #12 TEK SCREW 18 "0C 0 UNIT TO CURB CURB BY MECH. CONTRACTOR 4x P.T. SLEEPER RIPPED TO LEVEL UNIT clo EXISTING " 1X8 W /LUS46 2x STIFFENERS HANGER EA HEAD OFF W /4x8 END RECEIVED OCT 2 9 2008 PERMIT CENTER PROJECT: GATEWAY N SUITE 9, BUILDING 5 RTU CLIENT: PRECISION BUILDERS JOB NO: 08211 DATE: 09/20/08 SHEET: S -1 CT ENGINEERING Structural Engineers INC STRUCTURAL CALCULATIONS FOR Gateway N. Suite 109, Building 5 New Roof Top Unit GENERAL CONTRACTOR PRECISION BUILDERS MECHANICAL CONTRACTOR SEATTLE MECHANICAL 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285-4512(V) (206) 285- 0618(F) Project: Ga k,w I ct,l H. a /o I N C l &1a 5 1 2 Client: Pre CA /v-YV /3 tJ / CIO rs Structural Engineers 464 Date: g Page Number: d ` 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285 -4512 FAX: (206) 285-0618 111 QuJ cwt 5F 7D �3�U•r► d o Carlo S-6 5. Zv V citac,L, c6,4) y , (, (p 7) / I � / 1 a - 1 - ; 2 K. p5C. .3 ` 0.3. . t 135'. f 23, .fie l fin, = r / $ - . 3� X 13 � i - l r . Z = Z d / '( 2.0 7 hic)(1e8D Project: Client: Structural Engineers 6 / S I ", i /c1 S pfzig&i5toio f-) d 47e R Tu Date: ! 7-0 -6 Page Number: S 2i 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285 -4512 FAX: (206) 285-0618 1BC2006 (1613), ASCE 7 -05 CHAPTER 11, 12, 13 SEISMIC DESIGN CRITERIA Response Spectral Acc. (0.2 sec) $ = 150.90 %g = 1.5099 Figure 22 -1 through 22 -14 Response Spectral Acc.( 1.0 sec) $ = 52.10 %g �).521g Figure 22 -1 through 22 -14 G� wa N `� r,�-. I `/ Soil Site Clas D 0 Table 2r ' Default = D ( � / t Site Coefficient F, = 1.000 Table 11.4 -1 �t Site Coefficient F.= 1.500 Table 11.4 -2 C! Max Considered Earthquake Acc. $, = F,.S, = 1.509 1.4-1) I ak- 1 i Loi-i = t 2? . Max Considered Earthquake Acc. $„ = FS = 0.782 (11 Building Occupancy Categories Design Category Consideration: Seismic Design Category for 0.1 sec Seismic Design Category for 1.0sec st < .75g Since Ta <.8Ts (see below), SDC = 12.8 Equivalent lateral force procedure B, Standard flexible Diaphragm - V with dist. between seismic Table 11.6 -1 Table 11.6 -2 Section 11.6 Control (exception of Section 11 6 does not apply) Comply with Seismic Design Category D T- R30t2.2.1.1 D D NA D Seismic Force Resisting Systems C, = 0.02 Building ht. 11, = 25 C.= 1.400 Approx Fundamental period, j = coo' Calculated T shall not exceeds Cu.Ta 0.8Ts = 0.8(S /S is structure Regular 8S 5 stories 9 Response Spectral Am( 0.2 sec) $= 1.500g F,= 1.00 5% Damped Design 5 = 2 /a(F,.S,) A. BEARING WALL SYSTEMS 1. Special reinforced concrete shear walls I Yes I -1 (R5/ ) a 2.5 1 1.0 z = 20 ft Max Fp= 1.6SDSbWp Min F = 0.3S Fp = 0.503 Wp 12.11.1 Structural Walls and Their Anchorage F = 0 IRC, Seismic Design Category= D2 x = 0.75 T- 12.8 -2 ft Limited Building Height (ft) =160 for S of 0.521g Table 12.8 -1 = 0.224 12.8 -7 T = .266 Sec For Ts T For T > For 5, t 0.6g Response Modification Coef. R = 5 Table - 12.2 -1 Over Strength Factorfl„ = 2 foot note g Importance factor Is 1 Table 11.5 -1 Seismic Base Shear V = C. W C,= WI =0.201 or need not to exceed, C, = S o' N/A (R/I).T or C.= T-T- - 0.283 C, shall not be less than = 0.01 Min C, = 0.5S,UR N/A Use C, = 0.201 Design base shear V = 0.201 W Control =0.313 USe 0.313 I - I sec. = 0.417 Control (exception of Section 11.6 does not apply) 12.8.1.3 Max Ss 5 1.5g = 1.000g (11.4-3) (12.8 -2) (12.8 -3) (12.8 -4) (12.8-5) (12.8.6) 12.14 Simplified Seismic base shear' 1. Special reinforced concrete shear walk 5% Damped Design SDS = 1.006 SDC = D F = 1.1 For two-story building V = FS = 0.221 W R 13.3 Seismic Demands on Nonstructural Components F p = 0.4a +2zJh) (13.3 -1) SDS= 1.006 R = 6 h =20ft = 1.610Wp = 0.302Wp Table 1 -1 S = I , o� resisting system >4011 G 1 ( 2 rD - m u Co Limitations: P R =5 T- 13.5 -1 or 13.6 -1 13.1.3 Fp = 0.503 Wp (13.3 -2) (13.3-3) 12.11.2 Anchorage of Concrete or Mason - . al Wa llgflexible diaphragm) or F = 400S = 402 shall bet 280 #/ft F = 0 . 8 Sosl(W,) (12.11.1) = 0.805Wp Max Seismic Load E. = flD t 0.2S (12.4.4), (12.4.5), (12.4,6), (12.4.7) Where fl, =2 0.2S = 0.202(0) Deflection Amplification factor G,= 5 Nonbuilding structures, Section 11 Response Modification Coef. R = 3 T- 15.4 -1 or T- 15.4 -2 Importance factor I= 1 15.4.1.1 For flexible nonbuilding, C = S = 0.335 Min C, = 0.03 (15.4 -1) or C,= 0.8 S,UR = 0.139 (15.4 -2) V =0.335W For rigid nonbuilding, C, = 0.3 S I (15.45) = 0.300W T -122 -1 T- 12.14 -I z87 S3 MD z .Vo g M/ I'-61/8" CONTROL BOX/ (460) BURNER 1 �AL CE55 I = I + I INDOOR FAN MOTOR Y BLOWER ACCESS PANEL ri 0' -4 3/16'7 (106.3] F - _I b oo o /0 0 0 6 UNIT STWEIGHTiT LB KG -C WEIGHT LB R1V KG W / LB WEIGHT KG (A) LB KG CORNER LB WEIGHT KG CORNER LB KG CORNER LB WEIGHT KG PANEL LENGTH 48T__004 460 209 50 22.7 90 40.9 140 63.5 105 47.6 159 72.1 56 25.4 1' -10 3/8" (568.0] 48T__005 470 213 I I f 142 64.4 106 48.1 162 73.5 60 27.2 I' -10 3/8' (568.0] 48T__006 490 222 + t i 150 68.0 119 52.2 160 72.6 65 29.5 1' -0 3/8" (315.0] THREADED CONDUIT SIZE WIRE USE REO'D HOLE SIZES (MAX ) 1/2 ACC. 7/8 "(22.2] I/2' 240 7/8 "(22.27 3/4" 1 1/4" (001,003) (002 / 004)POWER. POWER. 1 1/8'[28.4] 1 3/4 "(44.4) (003) 1/2 FPT GAS 1 1/4"(31.8] (004) 3 /4 "FPT GAS 1 5/8"[41.3] 48TM NOTES, 1. DIMENSIONS IN C ] ARE IN MILLIMETERS. 2. 0 CENTER OF GRAVITY. DIRECTION OF AIR FLOW. 4. ON VERTICAL DISCHARGE UNITS, DUCTWORK TO BE ATTACHED TO ACCESSORY ROOF CURB ONLY. FOR HORIZONTAL DISCHARGE UNITS FIELD SUPPLIED FLANGES SHOULD BE ATTACHED TO HORIZONTAL DISCHARGE OPENINGS, AND ALL DUCTWORK SHOULD BE ATTACHED TO THE FLANGES. S. MINIMUM CLEARANCE (LOCAL CODES OR JURISDICTION MAY MR CORNtyR a. BETWEEN UNIT, FLUE SIDE AND COMBUSTIBLE SURFACES, b. \ g3g6�TTIIN., 18 IN. W g A � CCES S( S p O � RY C F L LUE �I D E I NSC DEFLECTOR. 1 CURB) O INGHI T BOTTOM OF BlIE IL BLE USING SURFACES (WHEN NOT USING CURB) 0 INCHES. c. CONDENSER COIL, FOR PROPER AIR FLOW, 36 INCHES ONE SIDE, 12 INCHES THE OTHER. THE SIDE GETTING THE GREATER CLEARANCE 15 OPTIONAL. d. OVERHEAD, 60 INCHES TO ASSURE PROPER CONDENSER FAN OPERATION. e. BETWEEN UNITS, CONTROL BOX SIDE 42 IN. PER NEC. F. BETWEEN UNIT AND UNGROUNDED SURFACES, CONTROL BOX SIDE, 36 IN. PER NEC. 9. BETWEEN UNIT AND BLOCK OR CONCRETE WALLS AND OTHER GROUNDED SURFACES. CONTROL BOX SIDE, 42 IN. PER NEC. h. HORIZONTAL SUPPLY AND RETURN END, 0 INCHES WHEN THE ALTERNATE CONDENSATE DRAIN IS USED. 6. WITH THE EXCEPTION OF THE CLEARANCE FOR THE CONDENSER COIL AND COMBUSTION SIDE AS STATED IN NOTE •So, b, AND c, A REMOVABLE FENCE OR BARRICADE REQUIRES NO CLEARANCE. 7. UNITS MAY BE INSTALLED ON COMBUSTIBLE FLOORS MADE FROM W000 OR CLASS A, B, OR C ROOF COVERING MATERIAL IF SET ON BASERAIL. LEFT SIDE 3 -9" (1144] 8. THE VERTICAL CENTER OF GRAVITY IS 1'- 6'(457] UP FROM CORNER THE BOTTOM OF THE BASE RAIL. ELECTRICAL CORNER 'D DISCONNECT LOCATION BOTTOM OF UNIT 0' -4 9/16" TYP 3' 5 3/16' (115.8] 0' -2 9/16' (10467 (E5) LEFT S IDE 0' -3 13/16' (971 FLUE MOOD C / 2' -9 5/16" (846.5] Ii - ■I- 1' -4 5/16' (414.5] 0' -6 S /8' (168.2] II �II SEE NOTE 88 SEE BOTTOM POWER CHART(ELEC. ONLY) REAR 3' 1 1/2' (952.5] CONDENSER COIL COMPRESSOR ACCESS COVER 33 IIDA p E� II 0 (117] /4• II N ARASE NIN6T/ I 2' -0 1/4 2'- /2' (616] 1 >♦ 1 EVAPORATOR (622] COIL ' 15/16' (49] 0[4839. / 0 -1�1 /) 1 2' I _i 0' -3 S /I6" C96.0� (99.4] FRONT 0' -3 (906] 6' -1 11/16" [1 B72] OUTSIDE AIR' 2' -9 3 /B' (848] F/ ECONOMISERIV AND POWER EXHAUST ECONOMISER IV HOOD SUPPLY -AIR' OPENING VERTICAL '-0 1/6 (306] 1" ro S /2' [114] 0 3/8' (10) 0' -ii 7 /B' (301.6) BOTTOM POWER CHART, THESE HOLES REO'D FOR USE WITH ACCESSORY PACKAGES - CRBTMPWROO1A0I, 2A01, 3A01, OR 4A01 • - SELECT EITHER 3/4 OR 1 1/4 FOR POWER, DEPENDING ON WIRE SIZE. CORNER 'B p -2' t I1 /16' e0' [81-3 7 3/16- 1 (652] 1' -5 1/4" (438] F/ ECONOMISER IV RETURN -AIR OPENING (2.78] VERTICAL 0' -10 15/16" `Y4`•"' RETURN AIR r0' -5 3/8' 11137) } RIGHT SIDE 1 0 -2 9/16' (65] 1' - ( 5 45) ) f '"''"`VV 3/4 a* SUPPLY AIR 0 -5 7/16' (138] 0'-3 CORNER 'C' [ 1' -5 5/16" 439.7] 0' -7 1/4' (184] . -10 13/1•' 0274.6] j -- NNW A CONNECTION SIZES 13/B' DIA. (35] FIELD POWER SUPPLY HOLE 2' DIA. (51] POWER SUPPLY KNOCK -OUT 2 1/2' DIA. (64) POWER SUPPLY KNDCK-0UT 7/8' DIA. (22] FIELD CONTROL WIRING MOLE 3/4' -14 NAT CONDENSATE DRAIN I/2' - 14 NPT GAS CONNECTION VIEW S -S BLOCKOFF PANEL II II RETURN II AI OPENING II MORI- II ZONTAL II 7' II (177.8] II II 1'-8 1/4' (514) FILTER ACCESS PANEL (DISPOSABLE FILTERS) 0 0'-0 7/16%11.11 VERTICAL 0 " -4 1/16" ECONOMISERIV [103.2) W/ POWER EXHAUST FILTER ACCESS PANEL (DISPOSABLE FILTERS) 2' -1 1 /16' (652.5] )' -B 1/4' (514] OUTSIDE AIR O'- 0 7/8' (22 2] t 11111111111111M u. 2 (746.2] t 7/16 FORK TRUCK SLOTS 0' -5 3/4' Noma ' -1 IS/16' / � % 0' -S 11/16' 0' -8 ' / // U67 / 1658.61 4 (214] BAROMETRIC RELIEF DISCHARGE (144.3) BURNER ACCESS 0'-2 I /4'OIA OUT IDE / PANEL (57) OF PANEL `SUPPLY AIR RETURN AIR FRONT (TYP 8 PLACES) R I GHT S I E STD. CONDENSATE DRAIN Yw wt,ts.a r„ s_potte. 44. Gu,4 off CA cn ffw V/ V/ co O O 0) ESQUIP Product Data NEW ROOFTOP UNIT RTU -1 FELE COPY Copyright 2004 Carrier Corporation WEATHERMAKER® 48TM004 -028 WEATHERMASTER® 48HJ004 -028 Single- Package Rooftop Units Gas Heating/Electric Cooling KttV1tW ) t VO°2Si NOV 14 2008 Standard - Efficiency (TM) units meet minimum ASHRAE 90.1 ener- gy efficiency requirements. High - Efficiency (HJ) units well exceed ASHRAE 90.1 energy efficiency requirements. Gas heating with electric cooling rooftop units offer: • Pre - painted galvanized steel cabinet for long life and quality appearance • Commercial strength base rails with built -in rigging capability • Convertible design for vertical or hori- zontal supply /return (004-014 only) • Non - corrosive, sloped condensate drain pan, meets ASHRAE 62 (IAO) • Two -inch return -air filters • A wide assortment of factory- installed options available, including high- static drives that provide additional performance range • Optional factory- installed COBRATM energy recovery unit (option on 48HJ004 -014 units only) • Factory- installed PremierLinkT"' digital communicating controls — Factory installed optional gear driven EconoMi$er IV (vertical return for sizes 004 -012 only) for use with standard rooftop unit controls (includes CO2 sensor control capability) • Factory installed optional gear driven EconoMi$er2 (vertical return only) for use with PremierLink DDC controls (includes 4 to 20 mA actuator for demand control ventilation) • Humidi- MiZerTM adaptive dehumidi- fication system (48HJ004 -014) • MoistureMi$erTM dehumidification package Heat Options • Exclusive integrated gas control board with diagnostics • AlumagardTM heat exchanger coating • Induced -draft fan for gas combustion • Tubular, dimpled heat exchangers • Natural gas • LP conversion kits • Low NOx (size 004 -006 only) • Optional stainless steel heat exchangers. Form 48H,T -6PD K CE Ci Of Tukwila BWLD NCB DMSION Model number nomenclature (cont) 48 - Packaged Rooftop Electric Cooling/ Natural Gas Heat NJ - Constant Volume, High Efficiency Heat Options: 49 States D - Low Heat E - Medium Heat F - High Heat S - Low Heat / Stainless Steel R - Med Heat / Stainless Steel T - High Heat / Stainless Steel California Compliant G - Non NOx Low Heat (3 Ph, Single Stg) H - Non NOx Medium Heat (3 Ph, Single Stg) K - Non NOx High Heat (3 Ph, Single Stg) L - Low NOx Low Heat (Single Stg) M - Low NOx Medium Heat (Single Stg) N - Low NOx High Heat (Single Stg) Nominal Capacity -Tons 004 - 3 Tons 005 - 4 Tons 006 - 5 Tons 007 - 6 Tons 008 - 7- 1/2Tons 009 - 8-1/2 Tons 012 - 10 Tons 014 - 12- 1/2Tons Example: 48 NJ D T _ Controls and Sensors* Standard Unit - - None G - Hinged Access Panels H - Hinged Panels & PremierUinkv" Control N - Novar ETM3051 Control* P - PremierLink DDC Control R - Novar E1743051 & Hinged Panels' COBRA"' Energy Recovery Unit B - COBRA Unit & Std. RTU Controls C - COBRA Unit & Hinged Access Panels D - COBRA Unit & Hinged Panels & PremierLink Control E - COBRA Unit & PremierUnk Control LEGEND Al — Aluminum Cu — Copper DDC — Direct Digital Controls E-Ctd — E- Coated FIOP — Factory- Installed Option 'Contact factory for availability and applications. tRefer to 48HJ Price Pages, Quote Builder software or contact your local Carrier Representative for FIOP code table. NOTE: Hinged Access Panels include: Filter Panel, Control Box Panel, Fan Motor Panel, Compressor Panel. ENERGY STAR 48HJ004-012 UNITS ARE ENERGY STAR QUALIFIED 8 Quality Assurance Certified to ISO 9001:2000 48HJ004 -014 008 P M F 8 - Voltage 1 - 575-3-60 3 - 208/230 -1-60 5 - 208/230 -3-60 6 - 460-3-60 Coil Protection Options (fin/tube) Standard Unit - - AVCu Cond & AVCu Evap B - Cu/Cu Cond & Cu /Cu Evap C - Cu/Cu Cond & AVCu Evap E - E-Coat Al/Cu Cond & E-Coat AVCu Evap F - E-Coat Al/Cu Cond & AVCu Evap G - E-Coat Cu/Cu Cond & Al/Cu Evap ✓ - Al/Cu Pre -Coat Cond Fin & Al/Cu Evap COBRA"' Energy Recovery Unit H - 82AQ060 Al/Cu Supply & Exhaust /AVCu Cond & Evap J - 82AQ100 Al/Cu Supply & Exhaust / AVCu Cond & Evap K - 62AQ200 Al/Cu Supply & Exhaust / AVCu Cond & Evap . L - 62A0300 AVCu Supply & Exhaust / AVCu Cond & Evap M - 62AQ060 Cu/Cu Supply & Exhaust / Cu/Cu Cond & Evap N - 62AQ100 Cu /Cu Supply & Exhaust / Cu/Cu Cond & Evap P - 82AQ200 Cu /Cu Supply & Exhaust / Cu/Cu Cond & Evap O - 62AQ300 Cu /Cu Supply & Exhaust /Cu /Cu Cond & Evap R - 62AQ060 Cu /Cu Supply & Exhaust / Al /Cu Cond & Evap S - 82AQ100 Cu /Cu Supply & Exhaust /Al/Cu Cond & Evap T - 62AQ200 Cu /Cu Supply & Exhaust /Al/Cu Cond & Evap W - 62AQ300 Cu/Cu Supply & Exhaust /Al/Cu Cond & Evap X - 62A0060 E-Ctd AVCu Supply,Std. AVCu Exhaust / E -Ctd AVCu Cond & Std. Al /Cu Evap Y - 62AQ100 E-Ctd AVCu Supply,Std. AVCu Exhaust / E-Ctd AVCu Cord & Std. Al /Cu Evap Z - 82AQ200 E-Ctd Al /Cu Supply,Std. AVCu Exhaust / E-Ctd AVCu Cond & Std. Al/Cu Evap 1 - 62AQ300 E-Ctd Al/Cu Supply,Std. AVCu Exhaust / E -Ctd AVCu Cond & Std. AVCu Evap 2 - 62AQ060 E-Ctd AVCu Supply & Exhaust / E-Ctd Al/Cu Cond & Std. AVCu Evap 3 - 62AQ100 E-Ctd Al/Cu Supply & Exhaust / E-Ctd AVCu Cond & Std. Al/Cu Evap 4 - 62AQ200 E-Ctd Al /Cu Supply & Exhaust / E-Ctd AVCu Cond & Std. AVCu Evap 5 - 62AQ300 E-Ctd AVCu Supply & Exhaust / E-Ctd AVCu Cond & SW. AVCu Evap 8 - 62AQ060 E-Ctd AVCu Supply & Exhaust / E-Ctd AVCu Cond & Evap 7 - 62AQ100 E-Ctd AVCu Supply & Exhaust / E-Ctd Al/Cu Cond & Evap 8 - 62AQ200 E-Ctd AVCu Supply & Exhaust / E-Ctd Al/Cu Cond & Evap 9 - 82AQ300 E -Ctd Al /Cu Supply & Exhaust / E -Ctd Al/Cu Cond & Evap - HA Factory- Installed Options'!" Indoor Motor Options - - Standard Motor & Drive H - Humidi- MIZer"" & High Static Indoor Motor J - Humidi- MIZer, Cu/Cu with High -Static Motor K - E- coated Humidi -MIZer with High -Static Indoor Motor M - High -Static Indoor Motor COBRAtm f,' ,, aeergy receren UNIT 48HJ NOMINAL TONS COOLING (Btuh) TOTAL kW SEER. EER SOUND RATING ( decibels) IPLVt. 004 3 36,000 3.2 13.0 11.2" 76 N/A 005 4 46,000 4.1 13.0 11.1" 76 N/A 006 5 61,000 5.5 13.0 11.0" 80 N/A 007 6 73,000 6.7 - 11.0 80 N/A 008 7 90,000 8.2 - 11.0 82 11.6 009 81 /2 103,000 8.9 - 11.6 82 12.8 012 10 120,000 10.9 - 11.0 84 11.4 014 12.5 138,000 14.4 - 9.6 86 10.3 UNIT 48HJ INPUT CAPACITY OUTPUT CAPACITY TEMPERATURE RISE (°F) MINIMUM HEATING AIRFLOW (CFM) EFFICIENCY let Stage 2nd Stage 1st Stage 2nd Stage AFUE ( %) Steady State ( %) E/R004 72,000 - 58,000 - 25 -55 1004 82.8% 82.0 F/7'004 115,000 - 90,000 - 55 -85 1002 80.0% 80.0 1 D/S005 72,000 - 58,000 - 25 -55 1004 82.8% 82.0 E/R005 115,000 - 92,000 - 35-65 1320 81.0% 81.0 F/T005 150,000 - 118,000 - 50-80 1396 80.4% 80.0 D /S006 72,000 - 58,000 - 25 -55 1004 82.8% 82.0 E/R006 115,000 - 92,000 - 35-65 1327 81.0% 81.0 F/T006 150,000 - 118,000 - 50-80 1314 80.4% 80.0 UNIT 48HJ INPUT CAPACITY OUTPUT CAPACITY TEMPERATURE RISE (°F) MINIMUM HEATING AIRFLOW (CFM) EFFICIENCY 1st Stage 2nd Stage 1st Stage 2nd Stage AFUE ( %) Steady State ( %) M004 60,000 - 50,000 - 20-50 930 80.2% 81 .2 N004 90,000 - 74,000 - 30-60 1150 81.0% 81.4 L005 60,000 - 50,000 - 20-50 930 80.2% 81 .2 M005 90,000 - 74,000 - 30-60 1150 81.0% 81.4 N005 120,000 - 101,000 - 40-70 . 1340 80.7% 82.4 L006 60,000 - 50,000 - 20-50 930 80.2% 81.2 M006 90,000 - 74,000 - 30-60 1150 81.0% 81.4 N006 120,000 - 101,000 - 40-70 1340 80.7% 82.4 ARI* capacity ratings (cont) LEGEND EER - Energy Efficiency Ratio IPLV - Integrated Part -Load Value SEER - Seasonal Energy Efficiency Ratio 'Air - Conditioning & Refrigeration Institute. .Applies only to units with capacity of 65,000 Btuh or less. "ARI does not require EER ratings for unit with capacity below 65,000 Btuh. For these units, the EER rating at ARI standard conditions is provided for informa- tion only ttThe IPLV is not applicable to single- compressor units. NOTES: 1. Rated in accordance with ARI Standard 210 -94 or 360 -93. 2. Ratings are net values, reflecting the effects of circulating fan heat. 3. Ratings are based on: Cooling Standard: 80 F db, 67 wb indoor entering -air temperature and 95 F db outdoor entering -air temperature. IPLV Standard: 80 F db, 67 F wb indoor entering -air temperature and 80 F db outdoor entering -air temperature. AFUE - Annual Fuel Util'zation Efficiency NOTE: Capacities for stainless steel heat exchanger units (S /R/T) are the same as standard units (D /E/F). 14 ARP CAPACITY RATINGS - 48HJ004 -014 HEATING CAPACITIES AND EFFICIENCIES - 48HJ004 -014 208/230 -1-60 - SINGLE -STAGE GAS HEAT 208/230 -1-60 - SINGLE -STAGE GAS HEAT - LOW NOx 4. All 48HJ004-014 units are in compliance with ASHRAE 90.1 2001 Energy Standard for minimum SEER and EER requirements. Refer to state and local codes or visit the following website' http: / /solstice.crest.org/efficiency/ bcap to determine if compliance with this standard pertains to a given geo- gaphical area of the United States. Physical data HJE/F/H/K/M/N/S/R/T004 3 530 15 50 115 1 42 1...22 3500 1 /4-825 180 1...10 x 10 1200 1.20 2.40 48 56 680 -1044 1075 -1455 Ball 2100 1.9/2.9 2.8/3.8 '/2 5 /8 4.5 4.5 1...A...36 1...A...39 10.0 -12.4 65 65 5 6 3 3V2 826 1233 5 /8 2...15 5.5 1...17 3.9 HJD/E/F /G/11/K/L/M/N/S/R/T005 4 540 23 50 115 1...22 3500 180 Centrifugal Type, Belt Drive 1...10 x 10 1600 • 1.20 2.40 48 56 770 -1165 1075 -1455 Ball 2100 1.9/2.0 2.8/3.8 1 /2 5 /e 4.0 4.0 1...A...36 1...A...39 10.0 -12.4 70 65 5 6 3 3 936 1233 5 /8 Enhanced Copper Tubes, Alumin 2...15 5.5 2...17 3.9 HJD/E/F /G/H/IU JM/N/S/R/T006 5 560 25 50 115 Scroll 1 1 53 50 R -22 AcutrolTM Metering Device 5 -8 10-2 10-0 12 -5 18-8 20-5 Propeller 1...22 4100 1 /4...1100 320 Enhanced Copper Tubes, Aluminum Lanced Fins 1...17 2...17 2...17 14.6 16.5 16.5 1...10 x 10 2000 1.30/2.40* 2.90 48/56' 56 1035 -1460 1300 -1685 Ball 2100 2.4/3.4 3.4/4.4 5 /8 5 /8 4.0 4.5 1....4...40 1...A...40 14.7 -15.5 75 60 6 5 3 3 1248 1396 5 /8 urn Double -Wavy Fins 4...15 5.5 2...17 3.9 BASE UNIT 48 NOMINAL CAPACITY OPERATING WEIGHT (lb) Unit Humidi- MIZerT" Adaptive Dehumidification System EconoMi$er IV Roof Curb COMPRESSOR Ouantity Oil (oz) REFRIGERANT TYPE Expansion Device Operating Charge (lb -oz) Standard Unit Unit With Humidi -Mizer Adaptive Dehumidification System CONDENSER FAN Quantity. Diameter (in.) Nominal Cfm Motor Hp...Rpm Watts Input (Total) CONDENSER COIL Rows...Fins/in. Total Face Area (sq ft) EVAPORATOR FAN Quantity...Size (In.) Nominal Cfm Maximum Continuous Bhp Std HI- Static Motor Frame Size Std Hi- Static Fan Rpm Range Std HI- Static Motor Bearing Type Maximum Fan Rpm Motor Pulley Pitch Diameter A/B (In.) Std HI- Static Nominal Motor Shaft Diameter (in.) Std HI- Static Fan Pulley Pitch Diameter (in.) Std HI- Static Belt - Type...Length (in.) Std Hi- Static Pulley Center Line Distance (in.) Speed Change per Full Pulley Turn n of Std Movable Pulley Maximum ( Full Hi-Static Std Turns from Closed Position HI-Static Factory Setting - Full Turns Open Std Hi-Static Factory Speed Setting (rpm) Std HI-Static Fan Shaft Diameter at Pulley (in.) EVAPORATOR COIL Standard Unit Rows...Fins/in. Total Face Area (sq ft) Unit with Humidi-Mizer Adaptive Dehumidification System Rows...Fins/in. Total Face Area (sq ft) 48HJ LEGEND Bhp - Brake Horsepower 'Single phase/three phase. tlndicates automatic reset. "60,000 and 72,000 Btuh heat input units have 2 burners. 90,000 and 120,000 Btuh heat input units have 3 burners. 115,000 Btuh heat input units and 150,000 Btuh Heat input units have 3 burners. ttAn LP kit is available as an accessory. Kit may be used at elevations as high as 2000 ft. If an LP kit is used with Low NOx units, the Low NOx baffle must be removed and the units will no longer be classified as Low NOx units. HJD/E/F/S/ R/T007 6 635 29 50 115 1 60 12- 8 23-14 1...22 4100 '/4...1100 320 2...17 21.3 1...10x 10 2400 2.40 2.90 56 56 1119 -1585 1300 -1685 Ball 2100 2.4/3.4 3.4/3.4 5 /e T /e 4.0 4.5 1...A...38 14.7 -15.5 95 60 5 5 3 3 1305 1396 5 /8 4...15 7.3 2...17 5.2 IlThree -phase standard models have heating inputs as shown. Single -phase standard models have one -stage heating with heating input values as follows: HJD005- 006,HJE004 - 72,000 Btuh HJE005- 006,HJF004 - 115,000 Btuh HJF005-006 - 150,000 Btuh "'California compliant three -phase models. tttCalifornia SCAQMD compliant low NO models have combustion products that are controlled to 40 nanograms per joule or less. NOTE: Capacities for stainless steel heat exchanger units (S /R/T) are the same as standard units (D /E/F). 119 BASE UNIT 48 HJE/F /H/K/NVWS/R/T004 HJD/E/F /G/H/K/UM/N/S/R/T005 HJD/E/F /G/H/K/UM/N/S/R/T006 HJD/E/F /S/R/T007 FURNACE SECTION Rollout Switch Cutout Temp (F )t Burner Orifice Diameter (in....drill size)'* Natural Gas — Std Liquid Propane — Alttt Thermostat Heat Anticipator Setting (amps) 208/230/460/575 v First Stage Second Stage Gas Input (Btuh) First Stage/Second Stage Efficiency (Steady State) ( %) Temperature Rise Range Manifold Pressure (in. wg) Natural Gas — Std Liquid Propane — Alt}t Maximum Static Pressure (in. wg) Field Gas Connection Size (in.) 195 HJE .113..33 HJF .113...33 — HJH .113...33 HJK .113...33 — HJM .102...38 HJN .102...38 — HJE .089...43 HJF .089...43 — HJH .089...43 HJK .089...43 - HJM .082...45 HJN .082...45 — .14 .14 HJEII 50,000/ 72,000 HJFII 82,000/115,000 — HJH"' —/ 72,000 HJK "'— /115,000 — HJMttt —1 60,000 HJNttt —/ 90,000 — HJE 82.8 HJF 80 — HJH82 HJK 80 — HJM 80.2 HJN 81 - HJE 25 -55 HJF 55 -85 — HJH 25 -55 HJK 55 -85 — HJM 20 -50 HJN 30-60 — 3.5 3.5 1.0 1 /2 195 HJD .113..33 HJE .113...33 HJF .129...30 HJG .113...33 HJH .113...33 HJK .129..30 HJL .102...38 HJM .102...38 HJN .116...32 HJD .089...43 HJE .089...43 HJF .104...37 HJG .089...45 HJH .089...45 HJK .102...38 HJL .082...45 HJM .082...45 HJN .094...42 .14 .14 HJDII 50,000/ 72,000 HJEII 82,000/115,000 HJFII 120,000/150,000 HJG "' —/ 72,000 HJH "' — /115,000 HJK*** — /150,000 HJLttt —/ 60,000 HJMttt --/ 90,000 HJNttt -- /120,000 HJD 82.8 HJE 81 HJF 80.4 HJG82 HJH 81 HJK 80 HJL 80.2 HJM 81 HJN 80.7 HJD 25 -25 HJE 35-65 HJF 50-80 HJG 25 -55 HJH 35 -65 HJK 50-80 HJL 20-50 HJM 30-60 HJN 40-70 3.5 3.5 1.0 1 /2 195 HJD .113...33 HJE .113...33 HJF .129...30 HJG .113...33 HJH .113...33 HJK .129..30 HJL .102...38 HJM .102...38 HJN .116...32 HJD .089...43 • HJE .089...43 HJF .104..37 HJG .089...43 HJH .089...43 HJK .104...37 HJL .082...45 HJM .082...45 HJN .094...42 .14 .14 HJDII 50,000/ 72,000 HJEII 82,000/115,000 HJFII 120,000/150,000 HJG "' —1 72,000 HJH"' -1115,000 HJK*** —/150,000 HJLttt —/ 60,000 HJMttt - 90,000 HJNttt — /120,000 HJD 82.8 HJE 81 HJF 80.4 HJG82 HJH 81 HJK 80 HJL 80.2 HJM 81 HJN 80.7 HJD 25 -55 HJE 35 -65 HJF 50-80 HJG 25 -55 HJH 35 -65 HJK 50-80 HJL 20-50 HJM 30-60 HJN 40-70 3.5 3.5 1.0 1 /2 195 HJD .113...33 HJE .113...33 HJF .129...30 — — — — — — HJD .089...43 HJE .089...43 HJF .104..37 — - — — — — .14 .14 HJD 50,000/ 72,000 HJE 82,000/115,000 HJF 120,000/150,000 — — — — — — HJD 82 HJE 81 HJF 80 — — — — - — HJD 25 -55 HJE 35 -65 HJF 50-80 — — — — — — 3.5 3.5 1.0 1 /2 HIGH - PRESSURE SWITCH (psig) Standard Compressor Internal Relief Cutout Reset (Auto.) 450 ± 50 428 320 LOSS-OF- CHARGE SWITCH/LOW- PRESSURE SWITCH (Liquid Line) (psig) Cutout Reset (Auto.) 7 ± 3 22 ± 5 FREEZE PROTECTION THERMOSTAT Opens (F) Closes (F) 30 ± 5 45 ± 5 OUTDOOR -AIR INLET SCREENS Cleanable. Screen quantity and size varies with option selected. RETURN -AIR FILTERS Quantity...Size(in.) Throwaway 2...16x25x2 I 4...16x16x2 Physical data 48HJ (cont) LEGEND Bhp — Brake Horsepower 'Single phase /three phase. tlndicates automatic reset. "60,000 and 72,000 Btuh heat input units have 2 burners. 90,000 and 120,000 Btuh heat input units have 3 burners. 115,000 Btuh heat input units and 150,000 Btuh Heat input units have 3 burners. ttAn LP kit is available as an accessory. Kit may be used at elevations as high as 2000 ft. If an LP kit is used with Low NOx units, the Low NOx baffle must be removed and the units will no longer be classified as Low NOx units. 120 y IlThree -phase standard models have heating inputs as shown. Single -phase standard models have one -stage heating with heating input values as follows: HJD005 -006,HJE004 — 72,000 Btuh HJE005 -006,HJF004 — 115,000 Btuh HJF005-006 — 150,000 Btuh "'California compliant three -phase models. tttCalifornia SCAQMD compliant low NO models have combustion products that are controlled to 40 nanograms per joule or less. NOTE: Capacities for stainless steel heat exchanger units (S /R/T) are the same as standard units (D /E/F). UNIT STD. LB KG `:CO LB KG W /PRE WEIGHT LB KG CORNER LB WEIGHT KG CORNER LB WEIGHT KG CORNER LB KG CORNER LB WEIGHT KG "J" FT -IN. MM 48HJ.004 530 240 50 22.7 90 40.9 127 57.6 122 55.3 138 62.6 143 64.9 2' -9 5/16" 846.5 48HJ•005 540 245 129 58.5 124 56.2 141 64.0 146 66.2 48HJ.006 560 254 134 60.8 129 58.5 146 66.2 151 68.5 + i 48HJ•007 635 288 f - t 152 68.9 147 66,7 165 74.8 171 77.5 3' -5 5/16' 1050 CONTROL BOX /COMPRESSOR/ BURNER ACCESS PANEL M. O i THREADED EEEE INDOOR FAN MOTOR B BLOWER ACCESS PANEL b CONDUIT SIZE SIZES (MAX.) i 7 /8' ACC. -_ -_- rr ' C J� f-0'-3 (91 . 5/16' [91.0] 1' -2 [376.6] _ = �I g©© o l0 100E BOTTOM POWER CHART, THESE HOLES REO'D FOR USE WITH ACCESSORY PACKAGES - CRBTMPWRDO1A01, 2A01, 3A01, OR 4A01 THREADED WIRE REO'D HOLE CONDUIT SIZE USE SIZES (MAX.) 1/2' ACC. 7/8"[22.2] 1/2' 24V 7/8'[22.2) 3/4' (001,003) POWER. 1 1/8"[28.41 1 1/4' (002 004)POWER. 1 3/4 (003) 1/2 FPT GAS 1 1/4'[31.8] (004) 3/4 'FPT GAS 1 5/8 '[41.31 • - SELECT EITHER 3/4' OR 1 1/4' FOR POWER, DEPENDING ON WIRE SIZE. 48 HJ NOTES, 1. DIMENSIONS IN [ ] ARE IN MILLIMETERS. 2. • CENTER OF GRAVITY. REAR 0 DIRECTION OF AIR FLOW. FILTER /ECONOMIZER ACCESS PANEL 4. ON VERTICAL DISCHARGE UNITS, DUCTWORK TO BE ATTACHED CONDENSER COIL TO ACCESSORY ROOF CURB ONLY. FOR HORIZONTAL DISCHARGE UNITS FIELD SUPPLIED FLANGES SHOULD BE ATTACHED TO HORIZONTAL DISCHARGE OPENINGS, AND ALL DUCTWORK SHOULD BE ATTACHED TO THE FLANGES. CORNER 'A' 2' 7 1/2' 1 3/4' S MINIM PREVAIL). CLEARANCE (LOCAL CODES OR JURISDICTION MAY i (800] d-[45] a. BETWEEN UNIT, FLUE SIDE AND COMBUSTIBLE SURFACES / f T ('�A 36 IN.,18 IN. WHEN USING ACCESSORY FLUE DISCHARGE DEFLTR, / b. BOTTOM OF UNIT TO COMBUSTIBLE SURFACES (WHEN NOT USING LEFT I I CURB) 1 INCH. S I DE ' BOTTOM OF 0E RAIL TO COMBUSTIBLE SURFACES (WHEN NOT I USING SERB) ) 0 INCHES. c. CONDENSER COIL, FOR PROPER AIR FLOW, 36 INCHES �I ONE SIDE, 12 INCHES THE OTHER. THE SIDE GETTING THE GREATER CLEARANCE IS OPTIONAL. M I d. OVERHEAD, 60 INCHES TO ASSURE PROPER CONDENSER FAN 11 OPERATION. 3 -9 I I e. BETWEEN UNITS, CONTROL BOX SIDE, 42 IN. PER NEC. [1144] �2' -0 1/4' / i E F. BETWEEN UNIT AND UNGROUNDED SURFACES, CONTROL BOX SIDE, 36 IN. PER NEC. I [616] / 0' -5 3/4 _ ALT. CONDENSATE g. BETWEEN UNIT AND BLOCK OR CONCRETE WALLS AND OTHER ,] I / [1471-- DRAIN OPENING GROUNDED SURFACES, CONTROL BOX SIDE, 42 IN. PER NEC. I / / IN BASEPAN h. HORIZONTAL SUPPLY AND RETURN END, 0 INCHES WHEN THE ALTERNATE CONDENSATE DRAIN 15 USED. \\ 6. WITH THE EXCEPTION OF THE CLEARANCE FOR THE CONDENSER 1 -9. 0 -1 7/8% fi'o- O' -1 15/16' COIL AND COMBUSTION SIDE AS STATED IN NOTE 450, b, [533] [49] [48.0] AND c, A REMOVABLE FENCE OR BARRICADE REQUIRES NO I ' -11 1/2" 0' -3 5/16" ljc CLEARANCE. I 0' �9 [290] 198.4] 7. UNITS MAY BE INSTALLED ON COMBUSTIBLE FLOORS MADE / 8 FROM WOOD OR CLASS A, B, OR C ROOF COVERING MATERIAL SEE BOTTOM POW R SEE NOTE 48 IF SET ON BASE RAIL. CHART(ELEC. ONLY) _ CORNER - 0" 2' -11 11/16' 0' -3 1/16' B. THE VERTICAL CENTER OF GRAVITY IS l' -6 - [457) UP FROM [906; [79]"' FROM THE BOTTOM OF THE BASE RAIL. [31-O 6 11/16" 0' -3 13/16' [1872] BOTTOM OF UNIT 1' -7 3/16' [487.4 O' -4 9/16' I 3' S 3/16' [115.8] TYP [1046] ) 0' -2 9/16' ELECTRICAL (65) LEFT S IDE D LOCAT ON [97] FACTORY SUPPLIED B FLUE HOOD 1 1' -4 5/16' [414.5] EVAPORATOR COIL r t OUTSIDE AIR 5 + 2' -9 3/8" [848] a 4 5 F/ ECONOMIHERIV AND 0 POWER EXHAUST -e. ' 14] ECONOM I BER IV HOOD 2' -1 11 /16' [652] RETURN AIR OPENING VERTICAL FRONT CORNER 'B 1 1 SUPPLY AIR 1 OPENING I VERTICAL 1 A 1' -5 1/4' [4381 FOR ECONOMIBERIV ■0' -3 3/16' R I GHT S IDE [811 1 \ I SUPPLY AIR OPENING \I I HORIZONTAL I RETURN AIR OPENING HORI- ZONTAL 7' [177.8] 0 1/16' o- [81) I -3 3/16 CORNER 'C' [306] 1' -5 S /16' [439.7] D' -0 3/8' p' -11 7 /B' (301.6] 0' -5 7/16' [138] 0' -5 3/8' 1 [137] FILTER ACCESS PANEL (DISPOSABLE FILTERS) 0' -10 15/16' 4e2E3 RETURN AIR [278] i L0' -2 9/16" [65] i' -5 3/4" SUPPLY AIR (451] ""ff BLOCKOFF PANEL 0 -7 1/4' [184] ' - 10 13/1.' [274.6) A C 0 CONNECTION SIZES 1 3/8' DIA. (35] FIELD POWER SUPPLY HOLE 2" DIA. (51] POWER SUPPLY KNOCK -OUT 1 3/4' DIA. (44] CHARGING PORT HOLE 7 /B' DIA. (22] FIELD CONTROL WIRING HOLE 3/4' 14 NPT CONDENSATE DRAIN 1/2' 14 NPT GAS CONNECTION 2 1/2 DIA. C64] POWER SUPPLY KNOCK -OUT l' -8 1/4' (514] 2' -1 1/16' [652.5] 0' -6 5 /B' [168.2] q L 2[3/8 7 6 ` T 3/"� 2' -1 15/16 0 -B 7/16 .FORK TRUCK SLOTS 0' -5 " / 1464 ] [658.6] (144.3] [214] 0' -2 1/4 "DIA OUT IDE SUPPLY AIR RETURN AIR FRONT (TYP 8 PLACES) OF PANEL RIGHT SIDE E STD. CONDENSATE DRAIN VIEW 5 - 5 1'6 1/2' [470] 0' -0 7/16'[11.1] VERTICAL O' -4 1 /16' ECONOMIBERIV [103.2] W/ POWER EXHAUST FILTER ACCESS PANEL (DISPOSABLE FILTERS) 1' -B 1/4 OUTSIDE AIR 0'- 0 7/8' [22 2] 0 -5 11/16' BAROMETRIC RELIEF DISCHARGE [514] ROOFCURB ACCFSSORY A UNIT SIZE CRRFCURBOOlAO1 1 -2 (356] 48HJ004-007 CRRFCURBOO2A01 2 -0 [610] 48HJ CONNECTOR PKG. ACC CRBTMPWR001 A01 CRBTMPWR002A01 CRBTMPWR003A01 CRBTMPWR004AO1 1' -9 11/16' [551] I I C • C C406] 0 ALT DRAIN HOLE 1 3/4'[44.5] GAS 3/4' 119] NPT 1/2 [12.7)APT 3/4'[19)NPT 0' -0 1/4'[7] POWER 3/4' (19] NPT 1 1/4 [31.7) 3/4'C19)NPT 1 1/4'[31.7] CONTROL 1/2"[12.7]NPT O ACCESSORY PWR 1/2'[12.7)NPY C76) d [ C76) d8 0' -0 7/16' C111 (BOLT HEADS) 1♦ I C I \ / A I % I 1 1 " -1 7/16" 1 C341) B SUPPLY AIR OPENING X 1'-7 13 [504 0' -3' C76] 0' -0 7/16' A I [11] [914) (BOLT HEADS) J 11 A / - rC��--� \ / / / t. RETURN AIR OPENING 1: 334 '1 B' 7 NOTES. 1. ROOFCURB ACCESSORY IS SHIPPED DISASSEMBLED. 2. INSULATED PANELS. 3. DIMENSIONS IN [ ] ARE IN MILLIMETERS. 4. ROOFCURBt GALVANIZED STEEL. S (FLANGESUOII DUCTTRESTRON CURB) 6. SE —DICE CLEARANCE 4 FEET ON EACH SIDE. (FIELD �(J SUPPLIED) 7. DIRECTION OF AIR FLOW. 8. CONNECTOR PACKAGES CRBTMPWROO1A01 AND 2A01 ARE FOR THRU- THE -CURB TYPE GAS. PACKAGES CRBTMPWR003A01 AND 4A01 ARE FOR THE THRU - THE - BOTTOM TYPE GAS CONNECTIONS. 0' - 9/16' [115.5] I I I I I I I 2' -7 5/8" I I C803] I I I I I I I -- - 0 -0 7/16' " REF (BOLT HEADS) A U I SUPPLY AIR RETURN AIR - , VIEW "A -A" HEAD OF BOLT TO BE ON INSIDE OF FLANGE 0' -1 7/8' [48) , - 0 7/16' n VIEW 'B" (BOLT HEADS) A J/ (TYP. ALL CORNERS) GASKET (SUPPLIED WITH CURB) [76) ROOFING FELT (FIELD SUPPLIED) OPENING FOR BASEPAN ENTRY CANT STRIP SERVICE (SEE NOTE .8) (FIELD SUPPLIED] 0' -2 1/2' ROOFING MATERIAL [64) (FIELD SUPPLIED) [152] INSIDE) 3' -0 15/16' [938) 0 (117 1 I RIGID INSULATION I (FIELD SUPPLIED) I I I I GAS SERVICE PLATE (SEE NOTE .8) ∎ • • 11 I • SEE VIEW "8%ad∎ ■ UNIT NAIL TYPICAL (4) SIDES COUNTER FLASHING (FIELD SUPPLIED) 0' -3 1/4' [83] 1 -4 13/16' C427] (INSIDE) 0' -0 1/4' C6.3] 5' -7 1/8' [17051 SECTION - C —C SCALE 1,4 SEE NOTE .2 0' -7 1/16" C179) (INSIDE) NOTES CAMBRIDGEPORT SURE -LOCK' CORNER FASTENING DEVICE 15 ACCEPTABLE ALTERNATE CONSTRUCTION. Te Air Ent Condenser (Edb) Air Entering Evaporator - Cfm/BF 900/0.14 1200/0.17 1500/0.20 Air Entering Evaporator - Ewb (F) 72 67 62 72 67 62 72 67 62 72 TC 41.9 38.7 35.7 43.5 40.8 37.7 44.8 41.8 39.0 75 SHC 20.4 25.2 29.7 21.8 28.2 33.8 23.3 30.7 37.0 35.7 kW 2.19 2.16 2.12 2.21 2.18 2.15 2.23 2.19 2.16 3.53 TC 40.7 37.5 34.5 42.1 39.3 36.4 43.5 40.4 37.6 85 SHC 19.9 24.7 29.2 21.5 27.7 33.2 23.2 30.3 36.4 60.2 kW 2.46 2.42 2.39 2.47 2.44 2.41 2.50 2.45 2.42 52.8 TC 39.3 36.1 33.1 40.8 ' ',37481 34.9 42.0 38.9 36.1 95 SHC 19.5 24.1 28.4 21.1 i27121 32.5 22.8 29.9 35.6 TC kW 2.75 2.71 2.66 2.77 .2:73, 2.69 2.79 2.74 2.71 65.6 TC 37.7 34.6 31.7 39.3 36.2 33.4 40.1 37.2 34.7 105 SHC 18.8 23.5 27.8 20.7 26.6 31.8 22.1 29.3 34.7 L4!45,, kW 3.06 3.02 2.98 3.09 3.04 3.01 3.10 3.06 3.03 57.7 TC 36.0 33.0 29.7 37.4 34.5 31.5 38.1 35.5 33.2 115 SHC 18.3 22.9 26.7 19.9 26.1 30.9 21.3 28.7 33.2 38.4 kW 3.41 3.36 3.31 3.43 3.39 3.34 3.44 3.41 3.37 5.06 TC 34.2 31.3 27.8 35.6 32.7 29.4 36.3 33.6 31.9 125 SHC 17.6 22.2 25.8 19.4 25.4 29.4 20.8 28.0 31.8 31.0 kW 3.78 3.73 3.66 3.80 3.76 3.71 3.81 3.78 3.75 Temp (F) Air Condenser (Edb) Air Entering Evaporator - Cfm/BF 1500/0.08 1750/0.09 2000/0.11 2500/0.13 Air Entering Evaporator - Ewb (F) 72 67 62 72 67 62 72 67 62 72 67 62 TC 70.8 65.4 58.5 72.5 67.3 61.1 73.0 68.4 62.8 74.8 70.3 64.8 75 SHC 34.1 42.7 49.9 35.7 45.5 54.2 36.8 48.0 57.8 39.6 53.0 63.4 kW 3.53 3.49 3.44 3.55 3.50 3.46 3.55 3.51 3.47 3.57 3.54 3.48 TC 68.9 63.2 55.3 70.5 65.1 57.9 72.2 66.4 60.2 73.2 68.1 62.9 85 SHC 33.5 41.8 48.4 35.0 44.8 52.8 37.0 47.6 56.8 39.3 52.5 62.4 kW 3.98 3.94 3.87 4.00 3.96 3.90 4.03 3.97 3.92 4.04 3.99 3.94 TC 66.8 60.6 52.4 68.3 ' 62:5 54.3 69.3 63.8 56.6 71.2 65.6 60.6 95 SHC 32.8 40.7 47.0 34.5 43:8 51.1 36.0 46.7 55.0 39.1 51.8 60.5 kW 4.48 4.43 4.35 4.50 L4!45,, 4.37 4.51 4.46 4.40 4.55 4.48 4.44 TC 64.3 57.7 49.9 65.9 59.8 51.7 66.9 61.1 54.1 68.4 62.8 58.4 105 SHC 32.0 39.6 45.8 33.7 42.8 49.7 35.3 45.7 53.5 38.4 51.0 58.4 kW 5.03 4.96 4.87 5.05 4.99 4.90 5.06 5.00 4.93 5.08 5.02 4.98 TC 61.5 54.8 47.3 62.8 56.7 49.1 64.0 58.2 51.6 65.4 59.9 56.1 115 SHC 31.0 38.4 44.5 32.5 41.6 48.2 34.4 44.6 51.6 37.4 50.0 56.1 kW 5.61 5.55 5.46 5.62 5.58 5.49 5.65 5.60 5.52 5.67 5.61 5.57 TC 58.7 51.6 44.5 59.9 53.4 46.2 60.8 54.9 49.0 62.2 56.8 53.5 125 SHC 30.0 37.2 43.1 31.7 40.4 46.2 33.3 43.4 48.9 36.4 48.9 53.4 kW 6.27 6.19 6.09 6.28 6.21 6.13 6.29 6.24 6.17 6.31 6.27 6.22 Performance data 48HJ 48HJ004 (3 TONS) Temp (F) Air Ent Condenser (Edb) 75 85 95 105 115 125 48HJ006 (5 TONS) COOLING CAPACITIES - STANDARD UNITS bdb = tedb TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW 72 54.0 26.1 2.81 52.2 25.4 3.20 50.7 24.9 3.64 48.8 24.3 4.12 46.5 23.4 4.64 43.8 22.5 5.19 67 50.7 32.7 2.80 48.9 32.0 3.19 46.9 31.1 3.61 44.5 30.2 4.09 41.1 28.9 4.59 37.5 27.4 5.13 62 44.2 37.5 2.76 41.9 36.4 3.15 39.5 35.0 3.57 36.7 33.6 4.03 34.3 32.4 4.53 32.4 31.5 5.05 Air Entering Evaporator - Cfm/BF Air Entering Evaporator - Ewb (F) 72 55.9 27.6 2.83 54.1 26.9 3.22 51.9 26.1 3.65 49.8 25.3 4.12 47.7 24.9 4.65 45.1 24.1 5.20 67 52.2 35.1 2.81 50.4 34.5 3.20 ` 33 X3:62,1 46.2 32.8 4.09 43.3 31.8 4.62 39.0 30.2 5.15 62 47.7 41.8 2.78 45.9 40.8 3.17 43.5 39.6 3.60 40.7 38.2 4.06 37.0 36.3 4.55 33.8 33.7 5.09 72 56.4 28.2 2.83 54.5 27.5 3.22 52.5 26.8 3.65 50.2 26.0 4.12 48.0 25.4 4.64 45.3 24.7 5.19 67 52.8 36.2 2.80 51.0 35.7 3.20 48.9 34.7 3.62 46.7 33.9 4.09 44.4 33.4 4.63 40.1 31.9 5.17 62 49.1 43.8 2.79 47.2 42.8 3.18 45.2 41.8 3.60 42.1 40.3 4.07 38.5 38.3 4.56 35.4 35.4 5.11 72 58.1 30.2 2.84 55.3 28.6 3.22 53.9 28.8 3.67 51.5 27.9 4.14 48.9 27.1 4.65 46.3 26.5 5.20 67 54.5 39.5 2.82 52.3 38.5 3.20 50.1 37.5 3.63 48.2 37.4 4.11 45.7 36.9 4.63 42.6 35.9 5.19 1200/0.17 1450/0.19 1600/0.21 2000/0.24 Standard Ratings LEGEND BF - Bypass Factor Edb - Entering Dry Bulb Ewb - Entering Wet Bulb kW - Compressor Motor Power Input SHC - Sensible Heat Capacity (1000 Btuh) Gross TC - Total Capacity (1000 Btuh) Gross NOTES: 1. Direct interpolation is permissible. Do not extrapolate. 2. The following formulas may be used: sensible capacity (Btuh) 1.10xcfm thwb = Wet -bulb temperature corresponding to enthalpy of air leaving evaporator coil (hn.th) hnvb = he,„b total capacity (Btuh) 4.5 x cfm Where: h.b = Enthalpy of air entering evaporator coil. 3. The SHC is based on 80 F edb temperature of air entering evapo- rator coil. Below 80 F edb, subtract (corr factor x cfm) from SHC. Above 80 F edb, add (corn factor x cfm) to SHC. Correction Factor = 1.10 x (1 - BF) x (edb - 80). 62 50.6 47.5 2.79 48.7 46.6 3.18 46.7 45.6 3.61 44.7 44.4 4.08 42.0 42.0 4.60 38.8 38.8 5.15 147 0o 48HJ005 (4 TONS) - STANDARD MOTOR (BELT DRIVE)' Airflow (Cfm) 1200 1300 1400 1500 1600 1700 1800 1900 2000 48HJ005 (4 TONS) - STANDARD MOTOR (BELT DRIVE Airflow (Cfm) 1200 1300 1400 1500 1600 1700 1800 1900 2000 48HJ005 (4 TONS) - HIGH- STATIC MOTOR (BELT DRIVE)' Airflow (Cfm) 1200 1300 1400 1500 1600 1700 1800 1900 2000 48HJ005 (4 TONS) - HIGH- STATIC MOTOR (BELT DRIVE)' (cont) Airflow (Cfm) 1200 1300 1400 1500 1600 1700 1800 1900 2000 FAN PERFORMANCE - VERTICAL DISCHARGE UNITS (cont) ) (cont) LEGEND Bhp - Brake Horsepower Watts - Input Watts to Motor 'Motor drive range: 770 to 1185 rpm. All other rpms require field - supplied drive. LEGEND Bhp - Brake Horsepower Watts - Input Watts to Motor *Motor drive range: 1075 to 1455 rpm. All other rpms require field - supplied drive. Refer to page 188 for general Fan Performance Data notes. NOTES: 1. Boldface indicates field- supplied drive is required. 2. Maximum continuous bhp is 1.20. Refer to page 188 for general Fan Performance Data notes. NOTES: 1. Boldface indicates field- supplied drive is required. 2. Maximum continuous bhp is 2.40. 0.2 Rpm 666 701 737 773 810 847 885 923 962 Bhp 0.26 0.31 0.36 0.42 0.49 0.57 0.66 0.75 0.85 Watts 257 306 361 422 491 567 652 745 847 0.4 Rpm 778 810 842 875 909 943 978 1014 1049 Bhp 0.37 0.43 0.49 0.57 0.65 0.73 0.83 0.94 1.05 Watts 367 426 491 564 643 730 826 930 1043 External Static Pressure (in. wg) 0.6 Rpm 871 901 931 963 994 1027 1060 1093 Bhp 0.47 0.54 0.62 0.70 0.79 0.89 1.00 1.11 Watts 471 540 616 699 790 888 994 1109 0.8 Rpm 952 981 1010 1040 1070 1101 1133 Bhp 0.57 0.65 0.74 0.84 0.94 1.05 1.16 Watts 572 651 738 831 932 1040 1157 Rpm 1025 1053 1081 1110 1140 1170 1.0 Bhp 0.67 0.76 0.86 0.96 1.08 1.20 Watts 670 760 856 960 1070 1189 1.2 Rpm 1093 1119 1147 1175 Bhp 0.77 0.87 0.98 1.09 Watts 767 866 972 1086 1.4 Rpm 1155 1181 1208 Bhp 0.87 0.98 1.09 Watts 861 970 1086 External Static Pressure (in. wg) 1.6 Rpm 1213 1239 Bhp 0.96 1.08 Watts 955 1073 1.8 Rpm 1268 1294 Bhp 1.05 1.18 Watts 1047 1175 Rpm 1321 2.0 Bhp 1.14 Watts 1137 0.2 Rpm 666 701 737 773 810 847 885 923 962 Bhp 0.26 0.31 0.36 0.42 0.49 0.57 0.66 0.75 0.85 Watts 257 306 361 422 491 567 652 745 847 0.4 Rpm 778 810 842 875 909 943 978 1014 1049 Bhp 0.37 0.43 0.49 0.57 0.65 0.73 0.83 0.94 1.05 Watts 367 426 491 564 643 730 826 930 1043 External Static Pressure (In. wg) 0.6 Rpm 871 901 931 963 994 1027 1060 1093 1127 Bhp 0.47 0.54 0.62 0.70 0.79 0.89 1.00 1.11 1.24 Watts 471 540 616 699 790 888 994 1109 1233 0.8 Rpm 952 981 1010 1040 1070 1101 1133 1165 1198 Bhp 0.57 0.65 0.74 0.84 0.94 1.05 1.16 1.29 1.42 Watts 572 651 738 831 932 1040 1157 1283 1417 Rpm 1025 1053 1081 1110 1140 1170 1200 1231 1263 1.0 Bhp 0.67 0.76 0.86 0.96 1.08 1.20 1.32 1.46 1.61 Watts 670 760 856 960 1070 1189 1316 1453 1598 1.2 Rpm 1093 1119 1147 1175 1204 1233 1262 1293 1323 Bhp 0.77 0.87 0.98 1.09 1.21 1.34 1.48 1.63 1.79 Watts 767 866 972 1086 1207 1336 1473 1620 1776 1.4 Rpm 1155 1181 1208 1235 1263 1292 1321 1350 1380 Bhp 0.87 0.98 1.09 1.22 1.35 1.49 1.64 1.79 1.96 Watts 861 970 1086 1209 1340 1480 1627 1784 1950 External Static Pressure (in. wg) 1.6 Rpm 1213 1239 1265 1292 1320 1348 1376 1405 1434 Bhp 0.96 1.08 1.21 1.34 1.48 1.63 1.79 1.96 2.13. Watts 955 1073 1199 1332 1472 1622 1779 1946 2123 1.8 Rpm 1268 1294 1320 1346 1373 1401 1428 1457 1486 Bhp 1.05 1.18 1.32 1.46 1.61 1.77 1.94 2.12 2.31 Watts 1047 1175 1310 1452 1603 1762 1930 2106 2293 Rpm 1321 1346 1371 1397 1424 1451 1479 . 1506 2.0 Bhp 1.14 1.28 1.43 1.58 1.74 1.91 2.09 2.28 Watts 1137 1275 1419 1572 1732 1901 2078 2265 165 UNIT 48HJ UNIT PHASE MAXIMUM CONTINUOUS BHP* MAXIMUM OPERATING WATTS` UNIT VOLTAGE MAXIMUM AMP DRAW 004 Single 1.20 1000 208/230 4.9 Three 1.20 1000 208/230 4.9 460 2.2 2120 ` 575 2.2 005 Single 1.20 1000 208/230 4.9 Three 1.20 1000 208/230 4.9 460 2.2 575 2.2 006 Single 1.30 1650 208/230 10.1 Three 2.40 2120 208/230 6.7 460 3.0 575 3.0 007 Three 2.40 2120 208/230 6.7 460 3.0 575 3.0 008,009 Three 2.90 2615 208/230 8.6 460 3.9 575 3.9 012 Three 3.70 3775 208/230 12.2 460 5.5 575 5.5 014 Three 5.25 4400 208/230 17.3 460 8.5 575 8.5 UNIT 48HJ UNIT PHASE MAXIMUM CONTINUOUS BHP' MAXIMUM OPERATING WATTS* UNIT VOLTAGE MAXIMUM AMP DRAW 004 Three 2.40 2120 208/230 6.7 460 3.0 575 3.0 005 Three 2.40 2120 208/230 6.7 460 3.0 575 3.0 006 Three 2.90 2615 208/230 8.6 460 3.9 575 3.9 007 Three 2.90 2615 208/230 8.6 460 3.9 575 3.9 008,009 Three 4.20 3775 208/230 12.2 460 5.5 575 5.5 012 Three 5.25 4400 208/230 17.3 460 8.5 575 8.5 Performance data 48HJ (cont) LEGEND Bhp - Brake Horsepower 'Extensive motor and electrical testing on these units ensures that the full horsepower and watts range of the motors can be utilized with confidence. Using the fan motors up to the ratings shown in this table will not result in nuisance tripping or premature motor failure. Unit warranty will not be affected. 212 EVAPORATOR -FAN MOTOR PERFORMANCE - STANDARD MOTOR - 48HJ004 -014 EVAPORATOR -FAN MOTOR PERFORMANCE - HIGH - STATIC MOTORS - 48HJ004 -014 LEGEND Bhp - Brake Horsepower *Extensive motor and electrical testing on these units ensures that the full horsepower and watts range of the motors can be utilized with confidence. Using the fan motors up to the ratings shown in this table will not result in nuisance tripping or premature motor failure. Unit warranty will not be affected. UNIT 48HJ ARI RATING (decibels) A- WEIGHTED (db) OCTAVE BANDS 63 125 250 500 1000 2000 4000 8000 004,005 76 76.0 55.9 66.0 64.0 66.2 68.4 64.5 61.7 57.3 006,007 80 80.0 59.1 68.9 68.7 71.9 74.0 68.9 65.7 59.0 008,009 82 82.0 62.2 69.3 71.5 74.7 76.2 72.9 68.7 61.5 012 84 84.0 64.6 71.1 73.3 76.9 77.6 73.7 70.6 63.7 014 86 86.0 63.7 69.9 72.5 78.2 81.1 77.3 73.3 66.8 015,017 88 87.6 90.8 88.7 86.4 84.3 83.5 78.4 75.6 66.8 020 -024 82 81.7 90.2 84.8 80.7 79.0 77.6 71.4 66.7 60.7 028 85 84.9 90.0 86.3 83.6 82.9 80.3 74.9 71.4 66.5 FAN PERFORMANCE USING ACCESSORY POWER EXHAUST (48HJ015,017) 0.3 0.2 - 0.1- 3500 4000 4500 CFM 5000 OUTDOOR SOUND POWER (TOTAL UNIT) LEGEND ARI - Air Conditioning and Refrigeration Institute NOTE: Indoor sound power is available in Carrier's Electronic Catalog Program (ECAT) for specific operating parameters. (1,10), 219 00 2 U NIT U H T NOMINAL VOLTAGE (V-Ph-Hz) VOLTAGE RANGE COMPRESSOR (each OFM (each) IFM COMBUSTION FAN MOTOR POWER SUPPLY' MINIMUM UNIT DISCONNECT SIZEt Min Max Qty RLA LRA FLA FLA FLA MCA MOCP" FLA LRA 004 (3 Tons) 208/230 -1 -60 187 254 1 16.0 88.0 0.7 4.9 .60 25.6/25.6 30/30 25/25 101/101 208/230 -3-60 187 254 10.3 77.0 0.7 4.9 .60 18.5/18.5 25/25 18/18 90/90 460 -3-60 414 508 5.1 39.0 0.4 2.2 .30 9.0 20 9 46 575 -3-60 518 632 42 31.0 0.4 22 .30 7.3 20 7 37 005 • (4 Tons) - 208/230 -1 -60 187 254 1 23.7 126.0 0.7 4.9 .60 35.2/35.2 45/45 34/34 139/139 208/230 -3-60 187 254 13.5 93.0 0.7 4.9 .60 22.5/22.5 30/30 22/22 106/106 460 -3-60 414 508 6.4 46.5 0.4 2.2 .30 10.6 20 10 54 575 -3-60 518 632 6.4 40.0 0.4 2.2 .30 10.1 20 10 46 006 (5 Tons) 208/230 -1 -60 187 254 1 28.8 169.0 1.5 8.8 .60 46.3/46.3 60 /60 45/45 216/216 208/230 -3-60 187 254 17.3 123.0 1.5 5.8 .60 28.9/28.9 35/35 28/28 168/168 460 -3-60 414 508 9.0 62.0 0.8 2.6 .30 14.7 20 14 84 575 -3-60 518 632 7.1 50.0 0.8 2.6 .30 11.6 20 11 68 007 (6 Tons) 208/230 -3-60 187 254 1 20.5 156.0 1.4 5.8 .60 32.8/32.8 40/40 32/32 200/200 460 -3-60 414 508 9.6 75.0 0.6 2.6 .30 15.2 20 15 97 575 -3-60 518 632 7.7 56.0 0.6 2.6 .30 12.2 20 12 74 008 (7'/2 Tons) 208/230 -3-60 187 254 2 12.4 88.0 1.4 7.5 .60 38.2/38.2 45/45 40/40 242/242 460-3-60 414 508 6.4 44.0 0.7 3.4 .30 19.2 25 20 121 575 -3-60 518 632 4.8 34.0 0.7 3.4 .30 14.6 20 15 95 009 (81/2 Tons) 208/230 -3-60 187 254 2 13.4 105.0 1.4 7.5 .60 40.2/40.2 45/45 42/42 276/276 460-3-60 414 508 7.4 55.0 0.7 3.4 .30 21.5 25 23 143 575 -3-60 518 632 6.4 44.0 0.7 3.4 .30 18.2 20 19 115 012 (10 Tons) 208/230 -3-60 187 254 2 17.6 125.0 1.4 10.6 .60 53/53 60 /60 56/56 341/341 460 -3-60 414 508 8.3 62.5 0.7 4.8 .30 24.9 30 26 171 575 -3 -60 518 632 6.3 50.0 0.7 4.8 .30 19.1 25 20 136 014 (12 Tons) 208/230 -3-60 187 254 2 19.0 156.0 1.4 15.0 .60 60.6/60.6 70/70tt 64/64 426/426 460 -3 -60 414 508 9.0 75.0 0.7 7.4 .30 29.1 35 31 207 575 -3-60 518 632 7.4 54.0 0.7 7.4 .30 23.7 30 25 154 POWER EXHAUST PART NO. MCA (230 v) MCA (460 v) MCA (575 v) MOCP (for separate power source) CRPWREXH021A01 N/A 0.68 N/A 15 CRPWREXH022A01 3.4 N/A 1.32 15 CRPWREXH023A01 N/A 1.4 N/A 15 CRPWREXH028A01 1.7 N/A 0.68 15 CRPWREXH029A01 N/A 0.7 N/A 15 CRPWREXH030A01 1.6 N/A 0.64 15 Electrical data 48HJ LEGEND FLA - Full Load Amps HACR - Heating, ir Conditioning and Refrigeration IFM - Indoor (Evaporator) Fan Motor LRA - Locked Rotor Amps MCA - Minimum Circuit Amps MOCP - Maximum Overcurrent Protection NEC - National Electrical Code OFM - Outdoor (Condenser) Fan Motor RLA - Rated Load Amps UL - Underwriters' Laboratories 48HJ004 -014 STANDARD MOTOR UNITS (WITHOUT ELECTRICAL CONVENIENCE OUTLET) The values listed in this table do not include power exhaust. See table at right for power exhaust requirements. tUsed to determine minimum disconnect per NEC. **Fuse or HACR circuit breaker. ttFuse only. NOTES: 1. In compliance with NEC requirements for multimotor and combination load equipment (refer to NEC Articles 430 and 440), the overcurrent protective device for the unit shall be fuse or HACR breaker. The UL, Canada units may be fuse or circuit breaker. 2. Electrical data based on 95 F ambient outdoor -air temperature * 10% voltage. 3. Unbalanced 3 -Phase Supply Voltage Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use the following formula to determine the percent of voltage imbalance. 220 = 100 x max voltage deviation from average voltage average voltage Example: Supply voltage is 460 -3-60. A B c AB = 452 v BC =464v AC = 455 v Average Voltage = 452 + 464 + 455 3 1371 3 = 457 Determine maximum deviation from average voltage. AB) 457- 452 =5v BC) 464 - 457 = 7 v AC) 457 - 455 = 2 v US Maximum deviation is 7 v. Determine percent of voltage imbalance. % Voltage Imbalance = 100 x 457 = 1.53% POWER EXHAUST ELECTRICAL DATA This amount of phase imbalance is satisfactory as it is below the maximum allowable 2 %. IMPORTANT: If the supply voltage phase imbalance is more than 2 %, contact your local electric utility company immediately. N/A - Not available NOTE: If a single power source is to be used, size wire to include power exhaust MCA and MOCP. Check MCA and MOCP when power exhaust is powered through the unit. Determine the new MCA including the power exhaust using the following formula: MCA New = MCA unit only + MCA of Power Exhaust For example, using a 48HJD006 - - -5 unit with MCA = 28.9 and MOCP = 35, with CRPWREXH030A01 power exhaust. MCA New = 28.9 amps + 1.6 amps = 30.5 amps If the new MCA does not exceed the published MOCP, then MOCP would not change. The MOCP in this example is 35 amps and the MCA New is below 35; therefore the MOCP is acceptable. If "MCA New" is larger than the published MOCP, raise the MOCP to the next larger size. For separate power, the MOCP for the power exhaust will be 15 amps per NEC. Load Express: Load Calculation Software Load Express: Load Calculation Software By: Seattle Mechanical General Job r �4 Job Description: Building Owner: Program User: Comments: Program was Run: Dataset Name: gwn 109 Seattle Mechanical 10/21/200.tt 2:40:33 PM C: \CDS \LOADEXP \DATA \STE 109.LE • Alternative 1 Alt1 Geographical Data Location: Weather File: Latitude: Elevation: Seattle, Washington Seattle, Washington 47 deg 386 ft Design Data Summer Dsn Dry Bult Summer Dsn Wet Bul Winter Design Dry Bu Density -Sp Heat Prod Design Simulation per MO92 FELE COPY 80.0 deg F 64.0 deg F 26.0 deg F 1.0988 Btu - min /(hr -ft3 -F) Apr To Nov • KKVIEWVtD FUR CODE COMPLIANCE APPROVED NOV 14 2008 Of Tukwila ItDIN D SIION Version 2.2 Title Page Building Peak Data Month /Hour: Jul Cooling Capacity: 48.2 Cooling Sensible: 38.9 Sensible Heat Ratio (SH Heating Capacity -55.4 / 15 Mbh Mbh 0.887 Mbh RECEWED OCT 2920 PERMIT CENTER Load Express: Load Calculation Software Version 2.2 Zone /Air Handler Descriptions Alternative - 1 Alt1 Zone /Air Handler Descriptions Air Handler Type Description 1 CONSTANT AHU1 Zone Type Description 1 Commercial Retail Zone1 Load Express: Load Calculation Software Alternative 1 Alt1 General Job Data Weather Location: Seattle, Washington Weather Region: Northwest Clg Simulation Start Month: Apr Clg Simulation End Month: Nov Zone Data Alternative Number: 1 Zone Number: 1 Floor Width: 74 ft Floor Length: 18 ft Ceiling Height: 10 ft Fir-to-Fir Height: 24 ft No. of Dup Zones: 1 Ceiling U- Factor: 0.05 Btu /(hr- F -ft2) Floor Calculation Type: Slab -On -Grade Floor Loss Coefficient: 0.73 Btu /(hr -F -ft) Floor Perimeter Length186.00 ft W H ft ft ROOF 1 74 x 18 PART 1 75 x 10 PART 2 75 x 10 PART 3 18 x 10 PART 4 18 x 10 Type Steel Deck, 5" Ins Frame, 0.75" gypsum board Frame, 0.75" gypsum board Frame, 0.75" gypsum board Frame, 0.75" gypsum board 1 -2 Story Office Building Opening Time: 8 am Building Closing Time: 6 pm Building Direction: 0 Clg Sensible SF: 10.00 Cooling Dry Bulb: Relative Humidity: Heating Dry Bulb: People Density: People Activity: People Sensible Load: People Latent Load: Misc. Equip. Type: Misc. Equip. Sensible Load Misc. Equip. Latent Load: Misc. Equip. Sensible to RV Lighting Intensity: Lighting Type: ecessed fluorescent, not vented 0.05 Light 0.39 0.39 0.39 0.39 0 RA 72 deg F 50 % 70 deg F 100 ft2 /pers General Office Space 210 Btuh /pers 255 Btuh /pers Microcomputers 350.00 Watt/pers 0.00 Watt/ft2 0 Btuh 1.20 Watt/ft2 North No 0 0 0 0 0 0 80 80 80 80 Clg Latent SF: 10 Htg Sensible SF: 10 People Diversity: 100 % Bldg Simulation Type: Cooling and Heating Ballast Factor: 1.00 % Percent Light to RA: 0 % Vent Type: General Office Space Vent Cool Design: 20.00 cfm /pers Vent Heat Design: 20.00 cfm /pers Supply Cool Design: 0 cfm Supply Heat Design: 0 cfm Infiltration Type: Pressurized, Average Construction Infilt. Cooling Desigi 0.30 ach /hr Infilt. Heating Desigi 0.30 ach /hr Room Exhaust: 0.00 cfm U- Factor Color Percent ( %) Direction Susp Ceil Tilt Cool Adj Heat Adj Dimension % Glass Shading Coeff Spc Temp Spc Temp deg F deg F 0 45 45 45 45 0.00 0.00 0.00 0.00 0.00 Version 2.2 Zone Input Data Shading Load Express: Load Calculation Software Air Handler Input Alternative 1 Air Handler 1 Fan Configuration: Fan & Motor Efficiency: Cooling Supply Air Temp: Heating Supply Air Temp: Minimum Relative Humidity: Supply Fan Static Pressure: Return Fan Static Pressure: CONSTANT AHU1 Draw 56.00 % 55.00 deg F 0.00 deg F 40 % 2.50 in H2O 2.00 in H2O Supply Duct Location: Supply Duct Insulation: Supply Duct Temp Rise: Return Duct Insulation: Return Duct Temp Rise: Terminal Type: Total Cool Airflow: Total Heat Airflow: Zone(s) Connected: Return Air R4 Duct Insulation 0.3 deg F TD R4 Duct Insulation 0.3 deg F TD CONSTANT 0 cfm 0 cfm 1 Load Express: Load Calculation Software versio2.2 Peak Load Information Alternative 1 Design Heating: Airflow (cfm) Space Total Heating Coil Total Outside % O.A Sensible Sensible Entering Leaving Humidification Air Handler ft/Type Btuh Btuh DB DB Btuh BLDG BLOCK - 33,403.40 - 55,435.80 - 7,149.5 BLDG PEAK - 33,403.40 - 55,435.80 - 7,149.5 1 CONSTANT 1,829.51 266.40 14.56 - 33,403.40 - 55,435.80 62.95 86.62 - 7,149.5 Design Cooling: Airflow (cfm) Cooling Cooling Coil Total Outside % OA Total Sensible S.H.R. Entering Leaving ft2/ton cfm/ton cfml t2 Total Air Handler #/Type Btuh Btuh DB WB DB WB tons BLDG BLOCK 48,215.70 42,784.70 0.89 331.51 4.0 BLDG PEAK 48,215.70 42,784.70 0.89 331.51 4.0 1 CONSTANT 1,829.51 266.40 14.56 48,215.70 42,784.70 0.89 74.63 60.72 53.07 51.32 331.51 455.3 1.4 4.0 Building Peak Load Components Mo/Hr: Bldg 7/15 Air Hand 1 7/15 Zone 1 7/15 Solar Cooling (Btuh) Heating (Btuh) Cond Internal OA+Inf Misc Total Cond OA +Inf Misc Total 7,676.6 25,830.9 4,467.9 5,857.0 43,832.4 - 27,146.8 - 16,099.9 - 7,149.5 - 50,396.2 7,676.6 25,830.9 4,467.9 5,857.0 43,832.4 - 27,146.8 - 16,099.9 - 7,149.5 - 50,396.2 7,676.6 25,830.9 4,467.9 5,857.0 43,832.4 - 27,146.8 - 16,099.9 - 7,149.5 - 50,396.2 Load Express: Load Calculation Software Psychrometric State Points - Alternative 1 AIt1 Zone 1 Dry Bulb Wet Bulb Temp Diff. Zone1 ( deg F ) ( deg F ) ( deg F ) Space 72.0 59.5 Zone Return Air Heat Pickup 0.3 Return Fan 1.3 Return Air 73.6 60.1 Outdoor Air 80.0 64.0 Return /Outdoor Air Mix 74.6 60.7 Blow Through Fan 0.0 Entering Coil 74.6 60.7 Leaving Coil 53.1 51.3 Draw Through Fan 1.6 Supply Duct Heat Gain 0.3 Supply Air 55.0 52.1 Percent Outside Air Space Sensible Heat Ratio (SHR) Coil Airflow 16.02 % 0.900 1,663 cfm Version 2.2 Psychrometrics Load Express: Load Calculation Software Sensible Load Profile (Mbh) Alternative 1 Alt1 Version 2.2 Sensible Load Profile Hour 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Air Hand 1 10 9 9 8 8 8 8 27 29 31 34 35 37 38 39 39 39 38 18 16 14 13 12 11 Bldg 10 9 9 8 8 8 8 27 29 31 34 35 37 38 39 39 39 38 18 16 14 13 12 11 Zone 1 10 9 9 8 8 8 8 27 29 31 34 35 37 38 39 39 39 38 18 16 14 13 12 11 Load Express: Load Calculation Software Peak Load Summary - Alternative 1 Air Hand 1 AHU1 Areas ( ft2 ) Floor: SlabOnG /ExFIr: Roof: Skylight: Wall: Wall Glass: Partition: 1,332.0 186.0 1,332.0 0.0 0.0 0.0 1,860.0 Alt1 Space Sens Load Spc Sens Ld W /Sfty Fctr Cool Airflow Cool Airflw W /Sfty Fctor Cooling Check Cool Check W /Sfty Fctr Heat Airflow Heat Airfiw W /Sfty Fctr 31,068.3 Btuh 34,175.2 Btuh 1,663 cfm 1,830 cfm 1.25 cfm /ft2 1.37 cfm /ft2 1,663 cfm 1,830 cfm Version 2.2 Peak Load Summary Heating Coil Peak Outside Air: OADB: 26 Cooling Coil Peak Peaked at Time: Mo /Hr: 7 / 15 Outside Air: OADB: 80 WB: 64 RELHUM: 41.8% Cooling Coil Peak Heating Coil Peak Total Load Sens Load Percnt of Tot Peak Tot Sens Percnt of Tot ( Btuh) ( Btuh ) ( %) ( Btuh) ( %) ENVELOPE LOADS Solar Skylight Solar 0.00 0.00 0.00 Glass Solar 0.00 0.00 0.00 Sub Total 0.00 0.00 0.00 0.00 0.00 Conducted Skylight 0.00 0.00 0.00 Roof 1,932.93 1,932.93 - 3,223.44 Glass 0.00 0.00 0.00 Wall 0.00 0.00 0.00 Partition 5,743.68 5,743.68 - 17,949.00 SlabOnG /ExFIr 0.00 0.00 - 5,974.32 Sub Total 7,676.61 7,676.61 17.51 - 27,146.80 53.87 INTERNAL LOADS Lights 5,003.57 5,003.57 0.00 People 6,002.74 2,606.14 0.00 Misc 14,824.60 14,824.60 0.00 Sub Total 25,830.90 22,434.30 58.93 0.00 0.00 MISC LOADS Outside Air 3,574.36 2,341.81 - 12,879.90 Humidification 0.00 0.00 - 7,149.52 Infiltration 893.59 585.45 - 3,219.99 Sup. Fan Heat 2,969.98 2,969.98 0.00 Ret. Fan Heat 2,375.99 2,375.99 0.00 Duct Heat Pkup 1,096.53 1,096.53 0.00 Exhaust Heat - 585.49 - 585.49 0.00 Sub Total 10,325.00 8,784.27 23.56 - 23,249.40 46.13 OV /UNDR Sizing 0.00 0.00 0.00 Grand Total 43,832.40 38,895.10 - 50,396.20 W /Safety Factor 48,215.70 42,784.70 - 55,435.80 Load Express: Load Calculation Software Peak Load Summary - Alternative 1 Air Hand 1 AHU1 Areas ( ft2 ) Floor: SlabOnG /ExFIr: Roof: Skylight: Wall: Wall Glass: Partition: 1,332.0 186.0 1,332.0 0.0 0.0 0.0 1,860.0 Alt1 Space Sens Load Spc Sens Ld W /Sfty Fctr Cool Airflow Cool Airflw W /Sfty Fctor Cooling Check Cool Check W /Sfty Fctr Heat Airflow Heat Airfiw W /Sfty Fctr 31,068.3 Btuh 34,175.2 Btuh 1,663 cfm 1,830 cfm 1.25 cfm /ft2 1.37 cfm /ft2 1,663 cfm 1,830 cfm Version 2.2 Peak Load Summary Heating Coil Peak Outside Air: OADB: 26 Cooling Coil Peak Peaked at Time: Mo /Hr: 7 / 15 Outside Air: OADB: 80 WB: 64 RELHUM: 41.8% Load Express: Load Calculation Software Version 2.2 Peak Load Summary Peak Load Summary - Alternative 1 Alt1 Bldg 1 Areas ( ft2 ) Floor: 1,332.0 SlabOnG /ExFIr: 186.0 Roof: 1,332.0 Skylight: 0.0 Wall: 0.0 Wall Glass: 0.0 Partition: 1,860.0 Heating Coil Peak Outside Air: OADB: 26 Cooling Coil Peak Peaked at Time: Mo /Hr: 7 / 15 Outside Air: OADB: 80 WB: 64 RELHUM: 41.8% Cooling Coil Peak Heating Coil Peak Total Load Sens Load Percnt of Tot Peak Tot Sens Percnt of Tot ( Btuh) ( Btuh ) (%) ( Btuh) ( %) ENVELOPE LOADS Solar Skylight Solar 0.00 0.00 0.00 Glass Solar 0.00 0.00 0.00 Sub Total 0.00 0.00 0.00 0.00 0.00 Conducted Skylight 0.00 0.00 0.00 Roof 1,932.93 1,932.93 - 3,223.44 Glass 0.00 0.00 0.00 Wall 0.00 0.00 0.00 Partition 5,743.68 5,743.68 - 17,949.00 SlabOnG / ExFlr 0.00 0.00 - 5,974.32 Sub Total 7,676.61 7,676.61 17.51 - 27,146.80 53.87 INTERNAL LOADS Lights 5,003.57 5,003.57 0.00 People 6,002.74 2,606.14 0.00 Misc 14,824.60 14,824.60 0.00 Sub Total 25,830.90 22,434.30 58.93 0.00 0.00 MISC LOADS Outside Air 3,574.36 2,341.81 - 12,879.90 Humidification 0.00 0.00 - 7,149.52 Infiltration 893.59 585.45 - 3,219.99 Sup. Fan Heat 2,969.98 2,969.98 0.00 Ret. Fan Heat 2,375.99 2,375.99 0.00 Duct Heat Pkup 1,096.53 1,096.53 0.00 Exhaust Heat - 585.49 - 585.49 0.00 Sub Total 10,325.00 8,784.27 23.56 - 23,249.40 46.13 OV /UNDR Sizing 0.00 0.00 0.00 Grand Total 43,832.40 38,895.10 - 50,396.20 W /Safety Factor 48,215.70 42,784.70 - 55,435.80 Load Express: Load Calculation Software Version 2.2 Peak Load Summary Peak Load Summary - Alternative 1 Alt1 Bldg 1 Areas ( ft2 ) Floor: 1,332.0 SlabOnG /ExFIr: 186.0 Roof: 1,332.0 Skylight: 0.0 Wall: 0.0 Wall Glass: 0.0 Partition: 1,860.0 Heating Coil Peak Outside Air: OADB: 26 Cooling Coil Peak Peaked at Time: Mo /Hr: 7 / 15 Outside Air: OADB: 80 WB: 64 RELHUM: 41.8% ' Load Express: Load Calculation Software Peak Load Summary - Alternative 1 Zone 1 Zone1 Areas ( ft2 ) Floor: SlabOnG /ExFIr: Roof: Skylight: Wall: Wall Glass: Partition: 1,332.0 186.0 1,332.0 0.0 0.0 0.0 1,860.0 Alt1 Space Sens Load Spc Sens Ld W /Sfty Fctr Cool Airflow Cool Airflw W /Sfty Fctor Cooling Check Cool Check W /Sfty Fctr Heat Airflow Heat Airflw W /Sfty Fctr 31,068.3 Btuh 34,175.2 Btuh 1,663 cfm 1,830 cfm 1.25 cfm /ft2 1.37 cfm /ft2 1,663 cfm 1,830 cfm Version 2.2 Peak Load Summary Heating Coil Peak Outside Air: OADB: 26 Cooling Coil Peak Peaked at Time: Mo /Hr: 7 / 15 Outside Air: OADB: 80 WB: 64 RELHUM: 41.8% Cooling Coil Peak Heating Coil Peak Total Load Sens Load Percnt of Tot Peak Tot Sens Percnt of Tot ( Btuh) ( Btuh ) ( %) ( Btuh) ( %) ENVELOPE LOADS Solar Skylight Solar 0.00 0.00 0.00 Glass Solar 0.00 0.00 0.00 Sub Total 0.00 0.00 0.00 0.00 0.00 Conducted Skylight 0.00 0.00 0.00 Roof 1,932.93 1,932.93 - 3,223.44 Glass 0.00 0.00 0.00 Wall 0.00 0.00 0.00 Partition 5,743.68 5,743.68 - 17,949.00 SlabOnG / ExFIr 0.00 0.00 - 5,974.32 Sub Total 7,676.61 7,676.61 17.51 - 27,146.80 53.87 INTERNAL LOADS Lights 5,003.57 5,003.57 0.00 People 6,002.74 2,606.14 0.00 Misc 14,824.60 14,824.60 0.00 Sub Total 25,830.90 22,434.30 58.93 0.00 0.00 MISC LOADS Outside Air 3,574.36 2,341.81 - 12,879.90 Humidification 0.00 0.00 - 7,149.52 Infiltration 893.59 585.45 - 3,219.99 Sup. Fan Heat 2,969.98 2,969.98 0.00 Ret. Fan Heat 2,375.99 2,375.99 0.00 Duct Heat Pkup 1,096.53 1,096.53 0.00 Exhaust Heat - 585.49 - 585.49 0.00 Sub Total 10,325.00 8,784.27 23.56 - 23,249.40 46.13 OV /UNDR Sizing 0.00 0.00 0.00 Grand Total 43,832.40 38,895.10 - 50,396.20 W /Safety Factor 48,215.70 42,784.70 - 55,435.80 ' Load Express: Load Calculation Software Peak Load Summary - Alternative 1 Zone 1 Zone1 Areas ( ft2 ) Floor: SlabOnG /ExFIr: Roof: Skylight: Wall: Wall Glass: Partition: 1,332.0 186.0 1,332.0 0.0 0.0 0.0 1,860.0 Alt1 Space Sens Load Spc Sens Ld W /Sfty Fctr Cool Airflow Cool Airflw W /Sfty Fctor Cooling Check Cool Check W /Sfty Fctr Heat Airflow Heat Airflw W /Sfty Fctr 31,068.3 Btuh 34,175.2 Btuh 1,663 cfm 1,830 cfm 1.25 cfm /ft2 1.37 cfm /ft2 1,663 cfm 1,830 cfm Version 2.2 Peak Load Summary Heating Coil Peak Outside Air: OADB: 26 Cooling Coil Peak Peaked at Time: Mo /Hr: 7 / 15 Outside Air: OADB: 80 WB: 64 RELHUM: 41.8% ACTIVITY NUMBER: M08 -259 DATE: 10 -29 -08 PROJECT NAME: COMMITTEE FOR A BETTER KING COUNTY SITE ADDRESS: 3415 S 116 ST - SUITE 109 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: 0 11 17-0 ng Division Public Works Complete Comments: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 • PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP L4. Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Planning Division ❑ Permit Coordinator DUE DATE: 10-30-08 Not Applicable 'Permit Cell ler'USe'Onl y vs: +{,,; .. s .. ? , :n • :;; rLw�,Se e; ,} dr;,..,�� " '.i Lr�?'.' , ;•i ; y tij :, INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS RO T ING: Please Route Structural Review Required ❑ No further Review Required DATE: DUE DATE: 11-27-08 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Bond Company Policy Effective Expiration Cancel Impaired Bond Amount Received Insurance Name Number Date Date Date Date Amount Date FEDERATED 2 MUTUAL 9821065 08/01/2008 08/01/2009 $1,000,000.00 06/16/2008 INS 1 CBIC C11SH5647 10/08/2007 10/08/2008 $1,000,000.00 10/17/2007 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 CBIC SH5647 10/08/2007 Until Cancelled $6,000.00 10/17/2007 Name 'Role Effective Date Expiration Date YATSUK, ROMAN OWNER 10/17/2007 Untitled Page General /Specialty Contractor A business registered as a construction contractor with LI:tI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company SEATTLE MECHANICAL 4252313123 5805 -A GLENWOOD AVE EVERETT WA 98203 SNOHOMISH INDIVIDUAL UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 602771144 ACTIVE SEATTM *932PP CONSTRUCTION CONTRACTOR 10/17/2007 10/17/2009 HTG /VENT /AIR CONDITIONING UNUSED Business Owner Information Bond Information Insurance Information I or Page 1 of 1 https: / /fortress.wa. gov /lni/bbip/Detail.aspx ?License= SEATTM* 932PP 12/03/2008 ITY SIT v N.T.S. P MAP ENERGY CODE NOTES 1) HEAT IS VIA GAS, NO ELECTRIC HEAT ALLOWED -NO CHANGE TO ENVELOPE 2) PROVIDE VAPOR ON ALL WALL TO THE WARM SIDE 3) CAULK AND SEAL ALL OPENINGS TO OUTSIDE OR UNHEATED SPACES INCLUDING WEATHER -- STRIPPING AT ALL EXTERIOR DOORS. 4 MAXIMUM ALLOWABLE LOAD FOR SWITCH IS 80% OF 20 AMP CIRCUIT. ) PROVIDE DUAL LEVEL SWITCHING IN ALL ROOMS ADJACENT TO EXTERIOR WINDOWS 5) BUILDING &SITE STATISTICS TAX PARCEL NUMBER: BUILDING CODE: TENEN I AREA: CONSTRUCTION: OCCUPANCY GROUP: ZONE: AREA OF WORK: - BUILDING AREA TOTAL BUILDING AREA= 27,750 S.F. - TENANT AREA AFTER IMPROVEMENTS: SUITE 109 OFFICE= 3,838 S.F. WAREHOUSE= 4,162 S.F. TOTAL= 8,000 S.F. - OCCUPANT LOAD: SUITE 109 OFFICE= WAREHOUSE TOTAL= SCOPE OF WORK: : Lp. \RI\TE PERMIT REQUIRED FOR: [ Mechanical *Electrical plumbing liGas Piping City of Tukwila 614..C; IN DIVISION 1023049043 2006 IBC W/ WA STATE AMENDMENTS SUITE 109 8,000 S.F. V-B FULLY SPRINKLED RED B OFFICE; S -1 STOR. C /LI (COMMERCIAL / LIGHT INDUSTRIAL) 1,100 S.F. 3,838 S.F. / 100= 38 OCC. (1 EXIT- TRAVEL DISTANCE) 4,162 S.F. / 500= 8 (1 EXIT) 46 OCCUPANTS INSTALLING NEW OFFICE TENANT IMPROVMENTS W/ INTERIOR NON- BEARING PARTITIONS, AND SUSP. ACOUSTIC CEILING LEGAL DESCRIPTION 102304 43 LOT 2 OF CITY OF TUKWILA SHORT PLAT NO 90 -2 -SS RECORDING NO 9003121482 SD SHORT PLAT DAF - POR OF GOV LOT 3 & OF SE 1/4 OF NE 1/4 OF SEC 09 -23 -04 TGW POR OF GOV LOT 6 & OF SW 1/4 OF NW 1/4 OF SECTION 10 -23 -04 - BAAP 70 FT RGT OF ENGR STA H 556 +57,3 BEING A PT ON NELY MGN SHEET 1 OF 7 FOR R/W SR 99 S 118TH ST TO JUNCTION SSH NO 1 -K APPROVED JULY 23, 1957 SD PT BEING PT OF TANGENCY OF CURVE THRU POINT BEARING N 42--02 -03 E 748.51 FT TH SELY ALG SD MGN & SAID CURVE THRU C/A OF 04 -26 -56 ARC DISTANCE OF 58.12 FT TH N 41 -57 -30 E 499.81 FT TH N 15 -27 -21 E 75,56 FT TO FOB TH S 74 -32 -39 E 21289 FT TH S 78 -39 -54 E 128,28 FT TH S` 81 -20 -44 E 447,24 FT TAP OF CURVE CONCAVE TO N TH ELY ALG SD CURVE RAD OF 170 FT THRU C/A OF 15 -51 -28 ARC DIST OF 47.05 FT TH N 82 -47 -48 E 101.13 FT TO WLY MGN OF POR OF SECTION 9 CONDEMNED IN SUPERIOR COURT CAUSE NO 646697 TH S 07 -08 -23 E 544,81 FT ALONG WESTERLY MARGIN TO A LN 60 FT N OF & PLW ENGR B -LINE AS SHOWN ON SHEET 1 OF 7 FOR R/W SR 99 SOUTH 118TH ST TO JUNCTION SSH 1-K APPROVED JULY 23, 1957 TH N 88 -10 - 42 W 630.87 FT TAP 60 FT RGT OF ENGR STA B 548 +00 SAID R/W PLANS TH N 79 -41 -19 W 35921 FT TAP 70 FT RGT OF ENGR STA H 551 +64,4 SD PT ALSO BEING PT OF CUVE CONCAVE TO NORTH RAD PT BEARING N 10 -18 -41 E 748,51 FT TH NWLY ALG SD CURVE THRU C/A OF 30 -03 -04 ARC DISTANCE OF 392.59 FT TH N 41 -57 -30 E 499.81 FT TH N 15 -27 -21 E 75,56 FT TO PUB revi w approval Is sublect to error; and cm!ssiona. /.p -r,,v.,., of construction documents deco net authorize t �c violation of any adopted code or ardinanc ^. t1ecc►pt 0` approved Field Copy and conditions is acknovAcdocd: City of Tukwila BU DING DPJ S!ON REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan revipw fees. MB25? RtVItYVtU I CODE COMPLIANCE APPROVED OV 1 4 2008 f Tukwila PIVI$ION RECEIVED OCT 2 92008 PERMIT cENTEF M un in Csi Ld 0 t o G I W IA _co z LCC uo CO <as OhTJ I T J C c• Equipment Schedultyley.1) Heating Tag Make Model CFM Cooling OA CFM V /Ph SOUND RATTNJO KNIT WEIGHT EER Net BTU`S db's RTU-1 CARRIER 48HJ005 1600 11.1 46,000 72,000 82.8% 300 460/3 76 , 540 unit with economiser Seven day programmable thermostat w /night setback I BUILDING ENVELOPE, ENTIRE SPACE IS HEATED AND COOLED USED PERSCRIPTIVE ON NEW SPACES WALL TYPES 1 er X 20 GA STEEL STUD 24' Q.C. TO ROOF STRUCTURE (2V APPROX.) WITH 5I6' GYP. BD. EACH SIDE W/ R -19 INSULATION FULL HEIGHT W/ VAPOR BARRIER OF WARM SIDE. PROVIDE DEFLECTION HEAD TRACK 2. 3 519" X 25 GA. STEEL STUD 0 24' O.C. TO 6' ABOVE CEILING GRID ow AFF) WITH 519' GYP. BO. EACH SIDE WI SOUND INSULATION. DOOR SCHEDULE (MATCH EXISTING) (LEVER HANDLE ON NEW DOORS) ( RE-USE EXISTING IF POSSIBLE) E Ex. DOORS, NO CHANGES 1,3 NEW 3.O' X 9'-0" S.C. WOOD (STAINE)) WITH WOOD JAMB (STAINED), 2 PAIR BUTTS, LOCKSET, WEATHERSTRIP, CLOSER,WALL STOP, THRESHOLD. 2 NEW 3'-0' X T'-0" S.0 WOOD DOOR (STAINED) WITH WOOD JAMB ( STAINED), 2 PAIR BUTTS, LATCHSET, SOUND GASKETS, WALL STOP, THRESHOLD. ROOM SCHEDULE 1 FLOOR: NEW CARPET BASE: NEW RUBBER BASE WALL: NEW GYP. BD. PAINT CEILING: NEW SUSPENDED ACOUSTICAL CEILING AT + 9' AFF WITH R-30 INSULATION 2 FLOOR: NEW VCT BASE: NEW RUBBER BASE WALL: NEW GYP. BD. PAINT CEILING: NEW SUSPENDED ACOUSTICAL CEILING AT +9' AFF WITH R-30 INSULATION INO NEW MECH UNIT #12x2'."W000 SCREW a 24 "OC Wo LAO SCREW a 24 "0C PENETRATE BEAM BELOW 4" MIN (EXPIRES S /t2/09 LEGEND EXISTING DOOR EXISTING 4X16 0 8' OC PARTIAL FRAMING NEW HVAC UNIT WITH CURB 520 # MAX EXISTING X8 W /LUS4O 2x STIFFENERS HANGER EA HEAD OFF W /4x6 ENO EXISTING Pl1RLIN o 8' OC EXISTING OLB SECTION A N TS PROJECT: GATEWAY N SUITE 9, BUILDING 5 RTIJ CLIENT: PRECISION BUILDERS HVAC CURB DETAIL NTS Structural Enpinssr• 160 Nickerson Street Suite SO2 Seattle, 1fA %SIMU 209205.4512 (V) 008.295_09 & (F) EXISTING WALL NEW STEEL STUD WALL TO UNDERSIDE OF CEILING mil/ EX. STEEL STUD WALL, BLOW IN SOUND INSULATION CAULK AT BASE, FURR WALL INSIDE EXISTING WALL OR DOOR TO BE REMOVED. NEW DOOR #12 TEIC SCREW 0 18 "0C 0 UNIT TO CURB CURD BY MECH. CONTRACTOR 4x P.T. SLEEPER I iPPEO TO LEVEL UNIT JOB NO: 08211 DATE: 09/20/08 SHEET: S -1 FOUR —PLEX OUTLET : DUPLEX OUTLET j WALL TELEPHONE OUTLET, MUDRING, CONDUIT AND PULL STRING ONLY. NEW OPEN OFFICE NORTH NEW OFFICE HVAC PLAN SCALE: 1/8" = i' -o" SCALE: 1 /8" = 1' -O" NEW HVAC: ADD 4 TON HVAC UNIT FOR NEW SPACE EXITING: OFFICE: OCCUPANT LOAD IS 38, WITH COMMON PAT OF TRAVEL UNDER 100 LF (1014.3 EXCEPTION 1) , SINGLE EXIT PER 1015. WAREHOUSE ALSO MEETS THE ABOVE. RENTABLE OFFICE: WAREHOUSE: TOTAL SF EXPANDED OFFICE 3,838 S.F. 4,162 S.F. 8,000 S.F. v DRIVE IN DOOR •DOCK HIGH DOOR Return air diffuser Supply diffuser Exhaust far EXISTING Thermostat Damper Vertical duct SUITE 125 OOF HATCH NEW ROOF TOP UNIT SUITE 109 HVAC LEGEND • -0 f 24 1 NORTH NEW ROOF TOP UNIT ROOF PLAN SCALE: 1/32" _ 50" 112' ELEVATION VIEW SOUTH NTS MIEBEDIBMIEIDE PROVIDE NEW 4TON GAS/ELECTRIC ROOF TOP UNIT WITH NEW WITH DUCTWORK AND DIFFUSERS FOR ADDED OFFICE SPACE. NO8 2S' • KtVitNI iw rUK CODE COMPLIANCE APPROVED NOV 1 4 2008 City Of Tukwila B !WIN AjVISION RECE:Air; OCT 29 2008 PERMIT CEN f - t) w 0 to to to 0 1 CO Q f+ N 0 2 v LO u7 z 0 a. 0 z E=+ E0 cn c4 o t-I E 4,1 .,„ 0.„ coo Z CO < L 3 0 v 0 4F' COMMITTEE FOR A BETTER KING COUNTY 3415 S 116 ST SUITE 109 M08 -259 Parcel No.: 1023049043 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: 3415 S 116 ST TUKW Contact Person: Name: TERRY COURSE Address: 899 W MAIN , AUBURN WA Contractor: Name: SEATTLE MECHANICAL Address: 5805 -A GLENWOOD AV , EVEREIT WA Contractor License No: SEATTM *932PP DESCRIPTION OF WORK: PROVIDE AND INSTALL NEW 4 TON GAS /ELECTRIC ROOF TOP UNIT, WITH NEW DUCTWORK AND DIFFUSERS Value of Mechanical: $12,000.00 Type of Fire Protection: COMMITTEE FOR A BETTER KING COUNTY 3415 S 116 ST - SUITE 109 , TUKWILA WA TTA/E PROPERTY TAX DEPT 207 PO BOX 4900 , SCOTTSDALE AZ Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial CitAf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT EQUIPMENT TYPE AND OUANTITY 0 0 0 0 0 0 1 0 0 0 0 0 0 0 * *continued on next page ** I Permit Number: Issue Date: Permit Expires On: Phone: Phone: 253 - 939 -9595 Phone: 425 231 -3123 Expiration Date: 10/17/2009 M08 -259 12/03/2008 06/01/2009 Fees Collected: $305.00 International Mechanical Code Edition: 2006 Boiler Compressor: 0-3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment doc: IMC-10/06 M08 -259 Printed: 12 -03 -2008 Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie Signature. Print Name: This permit shall or abandoned for • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us x- wit • Permit Number: M08 -259 Issue Date: 12/03/2008 Permit Expires On: 06/01/2009 Date: r; , 'V °1 ed thi permit and know the same to be true and correct. All provisions of law and ordinances , whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or authorized to sign and obtain this mechanical permit. Date: Veg come null an oid if the work is not commenced within 180 days from the date of issuance, or if the work is suspended eriod of 180 days from the last inspection. doc: IMC-10/06 M08 -259 Printed: 12 -03 -2008 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS • Parcel No.: 1023049043 Permit Number: M08 -259 Address: 3415 S 116 ST TUKW Status: ISSUED Suite No: Applied Date: 10/29/2008 Tenant: COMMITTEE FOR A BETTER KING COUNTY Issue Date: 12/03/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Cond - 10/06 * * continued on next page ** M08 -259 Printed: 12 -03 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. doc: Cond -10/06 Date: ) /( CJ M08 -259 Printed: 12 -03 -2008 SITE LOCATI ;A:. ,= 7X764W t' € lf4.; �d: =.H+n n:l - �i✓ . Site Address: 3415 S 116TH . Tenant Name: COMMITTEE FOR A BETTER KING CO. Property Owners Name: RREEF PROPERTY MGMT. Mailing Address: 12720 GATEWAY DRIVE, SUITE 200 TUKWILA WA. 98168 Zip Name: TERRY COURSE • CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 ht tp: / /www. ci. tukwila. wa. us Mailing Address: 899 west main Auburn wa. E -Mail Address: seattlemechanical@msn.com Contact Person: E -Mail Address: Contractor Registration Number: 14: •X'y4f.Vt _ :Y {� {P�,'T.'.y .�ifiY.Y t F. or.ofce. Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: 000480003 10)-30 to 1 i 3 Suite Number: 109 Floor: New Tenant: © Yes ❑ .. No • City State 11 �}- ..a ' w+d �T ?CSC. .ell. N t"J+•t :. „3.a,,t,nar 'A"y,::a -�' 'ACT P ERSON who do we contact whenyour_ permit is ready,.to be Issued g4P-igatSOPR:�,, ."_` .W., '�4'_'E.'e`,:f t i i[<�,?q,,.�i r"� •'V 'Al§ x4:41 .a 1 . y W : W :TV rte.' ,.;- tY Y�+.�.. t� 'idz .�•... �. �::. �t� Day Telephone: City State Fax Number: 253- 939 -9260 GE NERAL CQNTRACTOR (Contr=actor Information for Mech nical'(pg 4j for, Plumbing nd ?Gas Piping (pg Company Name: Mailing Address: City Day Telephone: Fax Number: Expiration Date: State vy�" G k ci•'ric4vrx i. .' k: A . t >E7 t� M�+ t v.? ��:� ARCHI TECT;OF RECO Alliplans must be''wet stamped•byoArcbkect of Recc ord t$ t,, r. �" i' ♦ ' t�• '.'.t' •;' : °z�4'i d7 v'cg� frr�"u.' •r�!!:. +.- - t; ,,s17 e Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: State State Zip Zip Zip � K .�xrTg �:' k= �EZiE?i;'.<:k �` L."EA'da � "` ' '%,`nb.- �' ^ew:: ' ' .3 ->+ : k^' n'"i `.; : �? E RD - ` ;All plans :must be wet stamped°by of Record ?aat' x ° a�h�` � t 4,? a kdE�, n w w x s iia gnA3t 2 1'a47tSW ct.`":a•. Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Q:\ApplicationsTFonna- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Zip Page 1 of 6 Unit Type: Qty • Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM 1 Incinerator — Comm/Ind Contact Person: TERRY COURSE rM CHXN tc- Atitki iNif RMA`TI 206 =431 3670 1= igi S�a ; �e?i3+: Asti: +, '. , +�z'. .eS� J- ` '. ° ,•✓ —' i :sLv'% = r �*$ 4 M.w. d ` FS MECHANICAL CONTRACTOR INFORMATION Company Name: IECS INC Mailing Address: 899 WEST MAIN AUBURN WA. 98001 Zip E-Mail Address: SEATTLE MEHCANICAL Contractor Registration Number: IECS * * * 044QL Valuation of Mechanical work (contractor's bid price): $ 12,000 Scope of Work (please provide detailed information): PROVIDE AND INSTALL NEW 4 TON GAS /ELECTRIC ROOF TOP UNIT. WITH NEW DUCTWORK AND DIFFUSERS. Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... [ Replacement .... ❑ Fuel Type: Electric ❑ Gas....® Other: Indicate type of mechanical work being installed and the quantity below: Q:Wpplications\Ponns- Applications On Line\3 -2006 - Permit Application.doc Revised: 9-2006 bh City State Day Telephone: 253 939 - 9495 Fax Number: 253 939 - 9260 Expiration Date: 11 /13 / 08 Page 4 of 6 BUILDING 0 Signature: Print Name: Mailing Address: , - �+� -, r , ,xi�+� is, i .;' JF �57ta.�'; . r••�:' Z {4'tv� °Cr' +•c- ,. a RNIIT APPLICATIONaNOTESt��Applica> ile � to � all�pelrmltssinithlstappLcation 3* r tac c a' '�" sn z tT z -r �*�.�3:ic4r�• .rf`.r'�• {'„�..:'�2h�t, Ku��i!'£ � ��-.�� r.,�.ri: t`.r:"s':rg •cxkow ~k *.`z s3rr >_mtiS,. Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. ORIZED AGENT: ,L)/ ►ki g`1 �✓-��' /G,f Date: 1/ ? 2dCS/ Day Telephone: u (fr. U"— City S tate I Date Application Accepted: Date Application Expires: Staff Initials: i Q:Wpplications'Fonns- Applications On Line\3.2006 • Permit Application.doc Revised: 9.2006 bh Page 6 of 6 Receipt No.: R08 -03642 Initials: User ID: Payee: WER 1655 IECS ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 42823 305.00 RECEIPT Parcel No.: 1023049043 Permit Number: M08 -259 Address: 3415 S 116 ST TUKW Status: PENDING Suite No: Applied Date: 10/29/2008 Applicant: COMMITTEE FOR A BETTER KING COUNTY Issue Date: Account Code Current Pmts 000.322.102.00.0 244.00 000/345.830 61.00 Total: $305.00 • Payment Amount: $305.00 Payment Date: 10/29/2008 11:33 AM Balance: $0.00 1 af 2- doc: Receiot -06 Printed: 10 -29 -2008 Projec t .0 imiat: tile Bek-eflq T of Inspecti . Address: i -i. Date Called: Special Instructions: Date Wanted: ' Z '4..• D a/ a 4p.m. Requester: Phone No: Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 AA i* , PERMIT NO. (206)431 -3670 Corrections required prior to approval. COMMENTS: I f)C ILA i a Le` PiA`. p c @AY Inspectc , , Date: / ? EJ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: i�; COMMENTS: • i Add i 5 i g- E 0 1 6 2e P.(- Pf /t r l ` e t IA Ali e 1 AAke. r I� r r4 Date Wanted: � � � a .m1 /Z O p.m Requester: 1 r C /)#' .e. • Ca I2 j f iv - r t A d Project: Type of In Rectio Add i 5 // 6 6--- Date Calledr ,'�� 4 Lie Special Instructions: : 00.„0 „. 1°.°..----- Date Wanted: � � � a .m1 /Z O p.m Requester: P hone ii0 2-.C-C —0045 INSPECTION NO. Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 60.00 REINSPECTION FEE REQ( IRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: M O' -25 PERMIT NO. (206)431 -3670 Date: C - -Or Corrections required prior to approval. CT ENGINEERING INC Struotural Engineers 180 Nickerson Street Suite 302 Seattle, WA 98109 208.285.4512 (V) 208.285.0818 (F) NEW MECH UNIT EXPIRES 5/12/09 J J U' #12 x 21/2" WOOD SCREW @ 24 "OC 3/4"0 LAG SCREW ® 24 "0C PENETRATE BEAM BELOW 4" MIN 4x6 EXISTING 4X16 @ 8' OC PARTIAL FRAMING PLAN NEW HVAC UNIT WITH CURB 520 # MAX NEW 4X8 AT SIDE W /LUS46 HANGER N TS EXISTING PURLIN ® 8' OC EXISTING GLB SECTION A 257 KtV1tWt) pp CC pp NCE MPPROED- ?„.. NOV 14 2008 Of Tukwila B I1.DIN DMSI I N #12 TEK SCREW 18 "0C 0 UNIT TO CURB CURB BY MECH. CONTRACTOR 4x P.T. SLEEPER RIPPED TO LEVEL UNIT clo EXISTING " 1X8 W /LUS46 2x STIFFENERS HANGER EA HEAD OFF W /4x8 END RECEIVED OCT 2 9 2008 PERMIT CENTER PROJECT: GATEWAY N SUITE 9, BUILDING 5 RTU CLIENT: PRECISION BUILDERS JOB NO: 08211 DATE: 09/20/08 SHEET: S -1 CT ENGINEERING Structural Engineers INC STRUCTURAL CALCULATIONS FOR Gateway N. Suite 109, Building 5 New Roof Top Unit GENERAL CONTRACTOR PRECISION BUILDERS MECHANICAL CONTRACTOR SEATTLE MECHANICAL 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285-4512(V) (206) 285- 0618(F) Project: Ga k,w I ct,l H. a /o I N C l &1a 5 1 2 Client: Pre CA /v-YV /3 tJ / CIO rs Structural Engineers 464 Date: g Page Number: d ` 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285 -4512 FAX: (206) 285-0618 111 QuJ cwt 5F 7D �3�U•r► d o Carlo S-6 5. Zv V citac,L, c6,4) y , (, (p 7) / I � / 1 a - 1 - ; 2 K. p5C. .3 ` 0.3. . t 135'. f 23, .fie l fin, = r / $ - . 3� X 13 � i - l r . Z = Z d / '( 2.0 7 hic)(1e8D Project: Client: Structural Engineers 6 / S I ", i /c1 S pfzig&i5toio f-) d 47e R Tu Date: ! 7-0 -6 Page Number: S 2i 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285 -4512 FAX: (206) 285-0618 1BC2006 (1613), ASCE 7 -05 CHAPTER 11, 12, 13 SEISMIC DESIGN CRITERIA Response Spectral Acc. (0.2 sec) $ = 150.90 %g = 1.5099 Figure 22 -1 through 22 -14 Response Spectral Acc.( 1.0 sec) $ = 52.10 %g �).521g Figure 22 -1 through 22 -14 G� wa N `� r,�-. I `/ Soil Site Clas D 0 Table 2r ' Default = D ( � / t Site Coefficient F, = 1.000 Table 11.4 -1 �t Site Coefficient F.= 1.500 Table 11.4 -2 C! Max Considered Earthquake Acc. $, = F,.S, = 1.509 1.4-1) I ak- 1 i Loi-i = t 2? . Max Considered Earthquake Acc. $„ = FS = 0.782 (11 Building Occupancy Categories Design Category Consideration: Seismic Design Category for 0.1 sec Seismic Design Category for 1.0sec st < .75g Since Ta <.8Ts (see below), SDC = 12.8 Equivalent lateral force procedure B, Standard flexible Diaphragm - V with dist. between seismic Table 11.6 -1 Table 11.6 -2 Section 11.6 Control (exception of Section 11 6 does not apply) Comply with Seismic Design Category D T- R30t2.2.1.1 D D NA D Seismic Force Resisting Systems C, = 0.02 Building ht. 11, = 25 C.= 1.400 Approx Fundamental period, j = coo' Calculated T shall not exceeds Cu.Ta 0.8Ts = 0.8(S /S is structure Regular 8S 5 stories 9 Response Spectral Am( 0.2 sec) $= 1.500g F,= 1.00 5% Damped Design 5 = 2 /a(F,.S,) A. BEARING WALL SYSTEMS 1. Special reinforced concrete shear walls I Yes I -1 (R5/ ) a 2.5 1 1.0 z = 20 ft Max Fp= 1.6SDSbWp Min F = 0.3S Fp = 0.503 Wp 12.11.1 Structural Walls and Their Anchorage F = 0 IRC, Seismic Design Category= D2 x = 0.75 T- 12.8 -2 ft Limited Building Height (ft) =160 for S of 0.521g Table 12.8 -1 = 0.224 12.8 -7 T = .266 Sec For Ts T For T > For 5, t 0.6g Response Modification Coef. R = 5 Table - 12.2 -1 Over Strength Factorfl„ = 2 foot note g Importance factor Is 1 Table 11.5 -1 Seismic Base Shear V = C. W C,= WI =0.201 or need not to exceed, C, = S o' N/A (R/I).T or C.= T-T- - 0.283 C, shall not be less than = 0.01 Min C, = 0.5S,UR N/A Use C, = 0.201 Design base shear V = 0.201 W Control =0.313 USe 0.313 I - I sec. = 0.417 Control (exception of Section 11.6 does not apply) 12.8.1.3 Max Ss 5 1.5g = 1.000g (11.4-3) (12.8 -2) (12.8 -3) (12.8 -4) (12.8-5) (12.8.6) 12.14 Simplified Seismic base shear' 1. Special reinforced concrete shear walk 5% Damped Design SDS = 1.006 SDC = D F = 1.1 For two-story building V = FS = 0.221 W R 13.3 Seismic Demands on Nonstructural Components F p = 0.4a +2zJh) (13.3 -1) SDS= 1.006 R = 6 h =20ft = 1.610Wp = 0.302Wp Table 1 -1 S = I , o� resisting system >4011 G 1 ( 2 rD - m u Co Limitations: P R =5 T- 13.5 -1 or 13.6 -1 13.1.3 Fp = 0.503 Wp (13.3 -2) (13.3-3) 12.11.2 Anchorage of Concrete or Mason - . al Wa llgflexible diaphragm) or F = 400S = 402 shall bet 280 #/ft F = 0 . 8 Sosl(W,) (12.11.1) = 0.805Wp Max Seismic Load E. = flD t 0.2S (12.4.4), (12.4.5), (12.4,6), (12.4.7) Where fl, =2 0.2S = 0.202(0) Deflection Amplification factor G,= 5 Nonbuilding structures, Section 11 Response Modification Coef. R = 3 T- 15.4 -1 or T- 15.4 -2 Importance factor I= 1 15.4.1.1 For flexible nonbuilding, C = S = 0.335 Min C, = 0.03 (15.4 -1) or C,= 0.8 S,UR = 0.139 (15.4 -2) V =0.335W For rigid nonbuilding, C, = 0.3 S I (15.45) = 0.300W T -122 -1 T- 12.14 -I z87 S3 MD z .Vo g M/ I'-61/8" CONTROL BOX/ (460) BURNER 1 �AL CE55 I = I + I INDOOR FAN MOTOR Y BLOWER ACCESS PANEL ri 0' -4 3/16'7 (106.3] F - _I b oo o /0 0 0 6 UNIT STWEIGHTiT LB KG -C WEIGHT LB R1V KG W / LB WEIGHT KG (A) LB KG CORNER LB WEIGHT KG CORNER LB KG CORNER LB WEIGHT KG PANEL LENGTH 48T__004 460 209 50 22.7 90 40.9 140 63.5 105 47.6 159 72.1 56 25.4 1' -10 3/8" (568.0] 48T__005 470 213 I I f 142 64.4 106 48.1 162 73.5 60 27.2 I' -10 3/8' (568.0] 48T__006 490 222 + t i 150 68.0 119 52.2 160 72.6 65 29.5 1' -0 3/8" (315.0] THREADED CONDUIT SIZE WIRE USE REO'D HOLE SIZES (MAX ) 1/2 ACC. 7/8 "(22.2] I/2' 240 7/8 "(22.27 3/4" 1 1/4" (001,003) (002 / 004)POWER. POWER. 1 1/8'[28.4] 1 3/4 "(44.4) (003) 1/2 FPT GAS 1 1/4"(31.8] (004) 3 /4 "FPT GAS 1 5/8"[41.3] 48TM NOTES, 1. DIMENSIONS IN C ] ARE IN MILLIMETERS. 2. 0 CENTER OF GRAVITY. DIRECTION OF AIR FLOW. 4. ON VERTICAL DISCHARGE UNITS, DUCTWORK TO BE ATTACHED TO ACCESSORY ROOF CURB ONLY. FOR HORIZONTAL DISCHARGE UNITS FIELD SUPPLIED FLANGES SHOULD BE ATTACHED TO HORIZONTAL DISCHARGE OPENINGS, AND ALL DUCTWORK SHOULD BE ATTACHED TO THE FLANGES. S. MINIMUM CLEARANCE (LOCAL CODES OR JURISDICTION MAY MR CORNtyR a. BETWEEN UNIT, FLUE SIDE AND COMBUSTIBLE SURFACES, b. \ g3g6�TTIIN., 18 IN. W g A � CCES S( S p O � RY C F L LUE �I D E I NSC DEFLECTOR. 1 CURB) O INGHI T BOTTOM OF BlIE IL BLE USING SURFACES (WHEN NOT USING CURB) 0 INCHES. c. CONDENSER COIL, FOR PROPER AIR FLOW, 36 INCHES ONE SIDE, 12 INCHES THE OTHER. THE SIDE GETTING THE GREATER CLEARANCE 15 OPTIONAL. d. OVERHEAD, 60 INCHES TO ASSURE PROPER CONDENSER FAN OPERATION. e. BETWEEN UNITS, CONTROL BOX SIDE 42 IN. PER NEC. F. BETWEEN UNIT AND UNGROUNDED SURFACES, CONTROL BOX SIDE, 36 IN. PER NEC. 9. BETWEEN UNIT AND BLOCK OR CONCRETE WALLS AND OTHER GROUNDED SURFACES. CONTROL BOX SIDE, 42 IN. PER NEC. h. HORIZONTAL SUPPLY AND RETURN END, 0 INCHES WHEN THE ALTERNATE CONDENSATE DRAIN IS USED. 6. WITH THE EXCEPTION OF THE CLEARANCE FOR THE CONDENSER COIL AND COMBUSTION SIDE AS STATED IN NOTE •So, b, AND c, A REMOVABLE FENCE OR BARRICADE REQUIRES NO CLEARANCE. 7. UNITS MAY BE INSTALLED ON COMBUSTIBLE FLOORS MADE FROM W000 OR CLASS A, B, OR C ROOF COVERING MATERIAL IF SET ON BASERAIL. LEFT SIDE 3 -9" (1144] 8. THE VERTICAL CENTER OF GRAVITY IS 1'- 6'(457] UP FROM CORNER THE BOTTOM OF THE BASE RAIL. ELECTRICAL CORNER 'D DISCONNECT LOCATION BOTTOM OF UNIT 0' -4 9/16" TYP 3' 5 3/16' (115.8] 0' -2 9/16' (10467 (E5) LEFT S IDE 0' -3 13/16' (971 FLUE MOOD C / 2' -9 5/16" (846.5] Ii - ■I- 1' -4 5/16' (414.5] 0' -6 S /8' (168.2] II �II SEE NOTE 88 SEE BOTTOM POWER CHART(ELEC. ONLY) REAR 3' 1 1/2' (952.5] CONDENSER COIL COMPRESSOR ACCESS COVER 33 IIDA p E� II 0 (117] /4• II N ARASE NIN6T/ I 2' -0 1/4 2'- /2' (616] 1 >♦ 1 EVAPORATOR (622] COIL ' 15/16' (49] 0[4839. / 0 -1�1 /) 1 2' I _i 0' -3 S /I6" C96.0� (99.4] FRONT 0' -3 (906] 6' -1 11/16" [1 B72] OUTSIDE AIR' 2' -9 3 /B' (848] F/ ECONOMISERIV AND POWER EXHAUST ECONOMISER IV HOOD SUPPLY -AIR' OPENING VERTICAL '-0 1/6 (306] 1" ro S /2' [114] 0 3/8' (10) 0' -ii 7 /B' (301.6) BOTTOM POWER CHART, THESE HOLES REO'D FOR USE WITH ACCESSORY PACKAGES - CRBTMPWROO1A0I, 2A01, 3A01, OR 4A01 • - SELECT EITHER 3/4 OR 1 1/4 FOR POWER, DEPENDING ON WIRE SIZE. CORNER 'B p -2' t I1 /16' e0' [81-3 7 3/16- 1 (652] 1' -5 1/4" (438] F/ ECONOMISER IV RETURN -AIR OPENING (2.78] VERTICAL 0' -10 15/16" `Y4`•"' RETURN AIR r0' -5 3/8' 11137) } RIGHT SIDE 1 0 -2 9/16' (65] 1' - ( 5 45) ) f '"''"`VV 3/4 a* SUPPLY AIR 0 -5 7/16' (138] 0'-3 CORNER 'C' [ 1' -5 5/16" 439.7] 0' -7 1/4' (184] . -10 13/1•' 0274.6] j -- NNW A CONNECTION SIZES 13/B' DIA. (35] FIELD POWER SUPPLY HOLE 2' DIA. (51] POWER SUPPLY KNOCK -OUT 2 1/2' DIA. (64) POWER SUPPLY KNDCK-0UT 7/8' DIA. (22] FIELD CONTROL WIRING MOLE 3/4' -14 NAT CONDENSATE DRAIN I/2' - 14 NPT GAS CONNECTION VIEW S -S BLOCKOFF PANEL II II RETURN II AI OPENING II MORI- II ZONTAL II 7' II (177.8] II II 1'-8 1/4' (514) FILTER ACCESS PANEL (DISPOSABLE FILTERS) 0 0'-0 7/16%11.11 VERTICAL 0 " -4 1/16" ECONOMISERIV [103.2) W/ POWER EXHAUST FILTER ACCESS PANEL (DISPOSABLE FILTERS) 2' -1 1 /16' (652.5] )' -B 1/4' (514] OUTSIDE AIR O'- 0 7/8' (22 2] t 11111111111111M u. 2 (746.2] t 7/16 FORK TRUCK SLOTS 0' -5 3/4' Noma ' -1 IS/16' / � % 0' -S 11/16' 0' -8 ' / // U67 / 1658.61 4 (214] BAROMETRIC RELIEF DISCHARGE (144.3) BURNER ACCESS 0'-2 I /4'OIA OUT IDE / PANEL (57) OF PANEL `SUPPLY AIR RETURN AIR FRONT (TYP 8 PLACES) R I GHT S I E STD. CONDENSATE DRAIN Yw wt,ts.a r„ s_potte. 44. Gu,4 off CA cn ffw V/ V/ co O O 0) ESQUIP Product Data NEW ROOFTOP UNIT RTU -1 FELE COPY Copyright 2004 Carrier Corporation WEATHERMAKER® 48TM004 -028 WEATHERMASTER® 48HJ004 -028 Single- Package Rooftop Units Gas Heating/Electric Cooling KttV1tW ) t VO°2Si NOV 14 2008 Standard - Efficiency (TM) units meet minimum ASHRAE 90.1 ener- gy efficiency requirements. High - Efficiency (HJ) units well exceed ASHRAE 90.1 energy efficiency requirements. Gas heating with electric cooling rooftop units offer: • Pre - painted galvanized steel cabinet for long life and quality appearance • Commercial strength base rails with built -in rigging capability • Convertible design for vertical or hori- zontal supply /return (004-014 only) • Non - corrosive, sloped condensate drain pan, meets ASHRAE 62 (IAO) • Two -inch return -air filters • A wide assortment of factory- installed options available, including high- static drives that provide additional performance range • Optional factory- installed COBRATM energy recovery unit (option on 48HJ004 -014 units only) • Factory- installed PremierLinkT"' digital communicating controls — Factory installed optional gear driven EconoMi$er IV (vertical return for sizes 004 -012 only) for use with standard rooftop unit controls (includes CO2 sensor control capability) • Factory installed optional gear driven EconoMi$er2 (vertical return only) for use with PremierLink DDC controls (includes 4 to 20 mA actuator for demand control ventilation) • Humidi- MiZerTM adaptive dehumidi- fication system (48HJ004 -014) • MoistureMi$erTM dehumidification package Heat Options • Exclusive integrated gas control board with diagnostics • AlumagardTM heat exchanger coating • Induced -draft fan for gas combustion • Tubular, dimpled heat exchangers • Natural gas • LP conversion kits • Low NOx (size 004 -006 only) • Optional stainless steel heat exchangers. Form 48H,T -6PD K CE Ci Of Tukwila BWLD NCB DMSION Model number nomenclature (cont) 48 - Packaged Rooftop Electric Cooling/ Natural Gas Heat NJ - Constant Volume, High Efficiency Heat Options: 49 States D - Low Heat E - Medium Heat F - High Heat S - Low Heat / Stainless Steel R - Med Heat / Stainless Steel T - High Heat / Stainless Steel California Compliant G - Non NOx Low Heat (3 Ph, Single Stg) H - Non NOx Medium Heat (3 Ph, Single Stg) K - Non NOx High Heat (3 Ph, Single Stg) L - Low NOx Low Heat (Single Stg) M - Low NOx Medium Heat (Single Stg) N - Low NOx High Heat (Single Stg) Nominal Capacity -Tons 004 - 3 Tons 005 - 4 Tons 006 - 5 Tons 007 - 6 Tons 008 - 7- 1/2Tons 009 - 8-1/2 Tons 012 - 10 Tons 014 - 12- 1/2Tons Example: 48 NJ D T _ Controls and Sensors* Standard Unit - - None G - Hinged Access Panels H - Hinged Panels & PremierUinkv" Control N - Novar ETM3051 Control* P - PremierLink DDC Control R - Novar E1743051 & Hinged Panels' COBRA"' Energy Recovery Unit B - COBRA Unit & Std. RTU Controls C - COBRA Unit & Hinged Access Panels D - COBRA Unit & Hinged Panels & PremierLink Control E - COBRA Unit & PremierUnk Control LEGEND Al — Aluminum Cu — Copper DDC — Direct Digital Controls E-Ctd — E- Coated FIOP — Factory- Installed Option 'Contact factory for availability and applications. tRefer to 48HJ Price Pages, Quote Builder software or contact your local Carrier Representative for FIOP code table. NOTE: Hinged Access Panels include: Filter Panel, Control Box Panel, Fan Motor Panel, Compressor Panel. ENERGY STAR 48HJ004-012 UNITS ARE ENERGY STAR QUALIFIED 8 Quality Assurance Certified to ISO 9001:2000 48HJ004 -014 008 P M F 8 - Voltage 1 - 575-3-60 3 - 208/230 -1-60 5 - 208/230 -3-60 6 - 460-3-60 Coil Protection Options (fin/tube) Standard Unit - - AVCu Cond & AVCu Evap B - Cu/Cu Cond & Cu /Cu Evap C - Cu/Cu Cond & AVCu Evap E - E-Coat Al/Cu Cond & E-Coat AVCu Evap F - E-Coat Al/Cu Cond & AVCu Evap G - E-Coat Cu/Cu Cond & Al/Cu Evap ✓ - Al/Cu Pre -Coat Cond Fin & Al/Cu Evap COBRA"' Energy Recovery Unit H - 82AQ060 Al/Cu Supply & Exhaust /AVCu Cond & Evap J - 82AQ100 Al/Cu Supply & Exhaust / AVCu Cond & Evap K - 62AQ200 Al/Cu Supply & Exhaust / AVCu Cond & Evap . L - 62A0300 AVCu Supply & Exhaust / AVCu Cond & Evap M - 62AQ060 Cu/Cu Supply & Exhaust / Cu/Cu Cond & Evap N - 62AQ100 Cu /Cu Supply & Exhaust / Cu/Cu Cond & Evap P - 82AQ200 Cu /Cu Supply & Exhaust / Cu/Cu Cond & Evap O - 62AQ300 Cu /Cu Supply & Exhaust /Cu /Cu Cond & Evap R - 62AQ060 Cu /Cu Supply & Exhaust / Al /Cu Cond & Evap S - 82AQ100 Cu /Cu Supply & Exhaust /Al/Cu Cond & Evap T - 62AQ200 Cu /Cu Supply & Exhaust /Al/Cu Cond & Evap W - 62AQ300 Cu/Cu Supply & Exhaust /Al/Cu Cond & Evap X - 62A0060 E-Ctd AVCu Supply,Std. AVCu Exhaust / E -Ctd AVCu Cond & Std. Al /Cu Evap Y - 62AQ100 E-Ctd AVCu Supply,Std. AVCu Exhaust / E-Ctd AVCu Cord & Std. Al /Cu Evap Z - 82AQ200 E-Ctd Al /Cu Supply,Std. AVCu Exhaust / E-Ctd AVCu Cond & Std. Al/Cu Evap 1 - 62AQ300 E-Ctd Al/Cu Supply,Std. AVCu Exhaust / E -Ctd AVCu Cond & Std. AVCu Evap 2 - 62AQ060 E-Ctd AVCu Supply & Exhaust / E-Ctd Al/Cu Cond & Std. AVCu Evap 3 - 62AQ100 E-Ctd Al/Cu Supply & Exhaust / E-Ctd AVCu Cond & Std. Al/Cu Evap 4 - 62AQ200 E-Ctd Al /Cu Supply & Exhaust / E-Ctd AVCu Cond & Std. AVCu Evap 5 - 62AQ300 E-Ctd AVCu Supply & Exhaust / E-Ctd AVCu Cond & SW. AVCu Evap 8 - 62AQ060 E-Ctd AVCu Supply & Exhaust / E-Ctd AVCu Cond & Evap 7 - 62AQ100 E-Ctd AVCu Supply & Exhaust / E-Ctd Al/Cu Cond & Evap 8 - 62AQ200 E-Ctd AVCu Supply & Exhaust / E-Ctd Al/Cu Cond & Evap 9 - 82AQ300 E -Ctd Al /Cu Supply & Exhaust / E -Ctd Al/Cu Cond & Evap - HA Factory- Installed Options'!" Indoor Motor Options - - Standard Motor & Drive H - Humidi- MIZer"" & High Static Indoor Motor J - Humidi- MIZer, Cu/Cu with High -Static Motor K - E- coated Humidi -MIZer with High -Static Indoor Motor M - High -Static Indoor Motor COBRAtm f,' ,, aeergy receren UNIT 48HJ NOMINAL TONS COOLING (Btuh) TOTAL kW SEER. EER SOUND RATING ( decibels) IPLVt. 004 3 36,000 3.2 13.0 11.2" 76 N/A 005 4 46,000 4.1 13.0 11.1" 76 N/A 006 5 61,000 5.5 13.0 11.0" 80 N/A 007 6 73,000 6.7 - 11.0 80 N/A 008 7 90,000 8.2 - 11.0 82 11.6 009 81 /2 103,000 8.9 - 11.6 82 12.8 012 10 120,000 10.9 - 11.0 84 11.4 014 12.5 138,000 14.4 - 9.6 86 10.3 UNIT 48HJ INPUT CAPACITY OUTPUT CAPACITY TEMPERATURE RISE (°F) MINIMUM HEATING AIRFLOW (CFM) EFFICIENCY let Stage 2nd Stage 1st Stage 2nd Stage AFUE ( %) Steady State ( %) E/R004 72,000 - 58,000 - 25 -55 1004 82.8% 82.0 F/7'004 115,000 - 90,000 - 55 -85 1002 80.0% 80.0 1 D/S005 72,000 - 58,000 - 25 -55 1004 82.8% 82.0 E/R005 115,000 - 92,000 - 35-65 1320 81.0% 81.0 F/T005 150,000 - 118,000 - 50-80 1396 80.4% 80.0 D /S006 72,000 - 58,000 - 25 -55 1004 82.8% 82.0 E/R006 115,000 - 92,000 - 35-65 1327 81.0% 81.0 F/T006 150,000 - 118,000 - 50-80 1314 80.4% 80.0 UNIT 48HJ INPUT CAPACITY OUTPUT CAPACITY TEMPERATURE RISE (°F) MINIMUM HEATING AIRFLOW (CFM) EFFICIENCY 1st Stage 2nd Stage 1st Stage 2nd Stage AFUE ( %) Steady State ( %) M004 60,000 - 50,000 - 20-50 930 80.2% 81 .2 N004 90,000 - 74,000 - 30-60 1150 81.0% 81.4 L005 60,000 - 50,000 - 20-50 930 80.2% 81 .2 M005 90,000 - 74,000 - 30-60 1150 81.0% 81.4 N005 120,000 - 101,000 - 40-70 . 1340 80.7% 82.4 L006 60,000 - 50,000 - 20-50 930 80.2% 81.2 M006 90,000 - 74,000 - 30-60 1150 81.0% 81.4 N006 120,000 - 101,000 - 40-70 1340 80.7% 82.4 ARI* capacity ratings (cont) LEGEND EER - Energy Efficiency Ratio IPLV - Integrated Part -Load Value SEER - Seasonal Energy Efficiency Ratio 'Air - Conditioning & Refrigeration Institute. .Applies only to units with capacity of 65,000 Btuh or less. "ARI does not require EER ratings for unit with capacity below 65,000 Btuh. For these units, the EER rating at ARI standard conditions is provided for informa- tion only ttThe IPLV is not applicable to single- compressor units. NOTES: 1. Rated in accordance with ARI Standard 210 -94 or 360 -93. 2. Ratings are net values, reflecting the effects of circulating fan heat. 3. Ratings are based on: Cooling Standard: 80 F db, 67 wb indoor entering -air temperature and 95 F db outdoor entering -air temperature. IPLV Standard: 80 F db, 67 F wb indoor entering -air temperature and 80 F db outdoor entering -air temperature. AFUE - Annual Fuel Util'zation Efficiency NOTE: Capacities for stainless steel heat exchanger units (S /R/T) are the same as standard units (D /E/F). 14 ARP CAPACITY RATINGS - 48HJ004 -014 HEATING CAPACITIES AND EFFICIENCIES - 48HJ004 -014 208/230 -1-60 - SINGLE -STAGE GAS HEAT 208/230 -1-60 - SINGLE -STAGE GAS HEAT - LOW NOx 4. All 48HJ004-014 units are in compliance with ASHRAE 90.1 2001 Energy Standard for minimum SEER and EER requirements. Refer to state and local codes or visit the following website' http: / /solstice.crest.org/efficiency/ bcap to determine if compliance with this standard pertains to a given geo- gaphical area of the United States. Physical data HJE/F/H/K/M/N/S/R/T004 3 530 15 50 115 1 42 1...22 3500 1 /4-825 180 1...10 x 10 1200 1.20 2.40 48 56 680 -1044 1075 -1455 Ball 2100 1.9/2.9 2.8/3.8 '/2 5 /8 4.5 4.5 1...A...36 1...A...39 10.0 -12.4 65 65 5 6 3 3V2 826 1233 5 /8 2...15 5.5 1...17 3.9 HJD/E/F /G/11/K/L/M/N/S/R/T005 4 540 23 50 115 1...22 3500 180 Centrifugal Type, Belt Drive 1...10 x 10 1600 • 1.20 2.40 48 56 770 -1165 1075 -1455 Ball 2100 1.9/2.0 2.8/3.8 1 /2 5 /e 4.0 4.0 1...A...36 1...A...39 10.0 -12.4 70 65 5 6 3 3 936 1233 5 /8 Enhanced Copper Tubes, Alumin 2...15 5.5 2...17 3.9 HJD/E/F /G/H/IU JM/N/S/R/T006 5 560 25 50 115 Scroll 1 1 53 50 R -22 AcutrolTM Metering Device 5 -8 10-2 10-0 12 -5 18-8 20-5 Propeller 1...22 4100 1 /4...1100 320 Enhanced Copper Tubes, Aluminum Lanced Fins 1...17 2...17 2...17 14.6 16.5 16.5 1...10 x 10 2000 1.30/2.40* 2.90 48/56' 56 1035 -1460 1300 -1685 Ball 2100 2.4/3.4 3.4/4.4 5 /8 5 /8 4.0 4.5 1....4...40 1...A...40 14.7 -15.5 75 60 6 5 3 3 1248 1396 5 /8 urn Double -Wavy Fins 4...15 5.5 2...17 3.9 BASE UNIT 48 NOMINAL CAPACITY OPERATING WEIGHT (lb) Unit Humidi- MIZerT" Adaptive Dehumidification System EconoMi$er IV Roof Curb COMPRESSOR Ouantity Oil (oz) REFRIGERANT TYPE Expansion Device Operating Charge (lb -oz) Standard Unit Unit With Humidi -Mizer Adaptive Dehumidification System CONDENSER FAN Quantity. Diameter (in.) Nominal Cfm Motor Hp...Rpm Watts Input (Total) CONDENSER COIL Rows...Fins/in. Total Face Area (sq ft) EVAPORATOR FAN Quantity...Size (In.) Nominal Cfm Maximum Continuous Bhp Std HI- Static Motor Frame Size Std Hi- Static Fan Rpm Range Std HI- Static Motor Bearing Type Maximum Fan Rpm Motor Pulley Pitch Diameter A/B (In.) Std HI- Static Nominal Motor Shaft Diameter (in.) Std HI- Static Fan Pulley Pitch Diameter (in.) Std HI- Static Belt - Type...Length (in.) Std Hi- Static Pulley Center Line Distance (in.) Speed Change per Full Pulley Turn n of Std Movable Pulley Maximum ( Full Hi-Static Std Turns from Closed Position HI-Static Factory Setting - Full Turns Open Std Hi-Static Factory Speed Setting (rpm) Std HI-Static Fan Shaft Diameter at Pulley (in.) EVAPORATOR COIL Standard Unit Rows...Fins/in. Total Face Area (sq ft) Unit with Humidi-Mizer Adaptive Dehumidification System Rows...Fins/in. Total Face Area (sq ft) 48HJ LEGEND Bhp - Brake Horsepower 'Single phase/three phase. tlndicates automatic reset. "60,000 and 72,000 Btuh heat input units have 2 burners. 90,000 and 120,000 Btuh heat input units have 3 burners. 115,000 Btuh heat input units and 150,000 Btuh Heat input units have 3 burners. ttAn LP kit is available as an accessory. Kit may be used at elevations as high as 2000 ft. If an LP kit is used with Low NOx units, the Low NOx baffle must be removed and the units will no longer be classified as Low NOx units. HJD/E/F/S/ R/T007 6 635 29 50 115 1 60 12- 8 23-14 1...22 4100 '/4...1100 320 2...17 21.3 1...10x 10 2400 2.40 2.90 56 56 1119 -1585 1300 -1685 Ball 2100 2.4/3.4 3.4/3.4 5 /e T /e 4.0 4.5 1...A...38 14.7 -15.5 95 60 5 5 3 3 1305 1396 5 /8 4...15 7.3 2...17 5.2 IlThree -phase standard models have heating inputs as shown. Single -phase standard models have one -stage heating with heating input values as follows: HJD005- 006,HJE004 - 72,000 Btuh HJE005- 006,HJF004 - 115,000 Btuh HJF005-006 - 150,000 Btuh "'California compliant three -phase models. tttCalifornia SCAQMD compliant low NO models have combustion products that are controlled to 40 nanograms per joule or less. NOTE: Capacities for stainless steel heat exchanger units (S /R/T) are the same as standard units (D /E/F). 119 BASE UNIT 48 HJE/F /H/K/NVWS/R/T004 HJD/E/F /G/H/K/UM/N/S/R/T005 HJD/E/F /G/H/K/UM/N/S/R/T006 HJD/E/F /S/R/T007 FURNACE SECTION Rollout Switch Cutout Temp (F )t Burner Orifice Diameter (in....drill size)'* Natural Gas — Std Liquid Propane — Alttt Thermostat Heat Anticipator Setting (amps) 208/230/460/575 v First Stage Second Stage Gas Input (Btuh) First Stage/Second Stage Efficiency (Steady State) ( %) Temperature Rise Range Manifold Pressure (in. wg) Natural Gas — Std Liquid Propane — Alt}t Maximum Static Pressure (in. wg) Field Gas Connection Size (in.) 195 HJE .113..33 HJF .113...33 — HJH .113...33 HJK .113...33 — HJM .102...38 HJN .102...38 — HJE .089...43 HJF .089...43 — HJH .089...43 HJK .089...43 - HJM .082...45 HJN .082...45 — .14 .14 HJEII 50,000/ 72,000 HJFII 82,000/115,000 — HJH"' —/ 72,000 HJK "'— /115,000 — HJMttt —1 60,000 HJNttt —/ 90,000 — HJE 82.8 HJF 80 — HJH82 HJK 80 — HJM 80.2 HJN 81 - HJE 25 -55 HJF 55 -85 — HJH 25 -55 HJK 55 -85 — HJM 20 -50 HJN 30-60 — 3.5 3.5 1.0 1 /2 195 HJD .113..33 HJE .113...33 HJF .129...30 HJG .113...33 HJH .113...33 HJK .129..30 HJL .102...38 HJM .102...38 HJN .116...32 HJD .089...43 HJE .089...43 HJF .104...37 HJG .089...45 HJH .089...45 HJK .102...38 HJL .082...45 HJM .082...45 HJN .094...42 .14 .14 HJDII 50,000/ 72,000 HJEII 82,000/115,000 HJFII 120,000/150,000 HJG "' —/ 72,000 HJH "' — /115,000 HJK*** — /150,000 HJLttt —/ 60,000 HJMttt --/ 90,000 HJNttt -- /120,000 HJD 82.8 HJE 81 HJF 80.4 HJG82 HJH 81 HJK 80 HJL 80.2 HJM 81 HJN 80.7 HJD 25 -25 HJE 35-65 HJF 50-80 HJG 25 -55 HJH 35 -65 HJK 50-80 HJL 20-50 HJM 30-60 HJN 40-70 3.5 3.5 1.0 1 /2 195 HJD .113...33 HJE .113...33 HJF .129...30 HJG .113...33 HJH .113...33 HJK .129..30 HJL .102...38 HJM .102...38 HJN .116...32 HJD .089...43 • HJE .089...43 HJF .104..37 HJG .089...43 HJH .089...43 HJK .104...37 HJL .082...45 HJM .082...45 HJN .094...42 .14 .14 HJDII 50,000/ 72,000 HJEII 82,000/115,000 HJFII 120,000/150,000 HJG "' —1 72,000 HJH"' -1115,000 HJK*** —/150,000 HJLttt —/ 60,000 HJMttt - 90,000 HJNttt — /120,000 HJD 82.8 HJE 81 HJF 80.4 HJG82 HJH 81 HJK 80 HJL 80.2 HJM 81 HJN 80.7 HJD 25 -55 HJE 35 -65 HJF 50-80 HJG 25 -55 HJH 35 -65 HJK 50-80 HJL 20-50 HJM 30-60 HJN 40-70 3.5 3.5 1.0 1 /2 195 HJD .113...33 HJE .113...33 HJF .129...30 — — — — — — HJD .089...43 HJE .089...43 HJF .104..37 — - — — — — .14 .14 HJD 50,000/ 72,000 HJE 82,000/115,000 HJF 120,000/150,000 — — — — — — HJD 82 HJE 81 HJF 80 — — — — - — HJD 25 -55 HJE 35 -65 HJF 50-80 — — — — — — 3.5 3.5 1.0 1 /2 HIGH - PRESSURE SWITCH (psig) Standard Compressor Internal Relief Cutout Reset (Auto.) 450 ± 50 428 320 LOSS-OF- CHARGE SWITCH/LOW- PRESSURE SWITCH (Liquid Line) (psig) Cutout Reset (Auto.) 7 ± 3 22 ± 5 FREEZE PROTECTION THERMOSTAT Opens (F) Closes (F) 30 ± 5 45 ± 5 OUTDOOR -AIR INLET SCREENS Cleanable. Screen quantity and size varies with option selected. RETURN -AIR FILTERS Quantity...Size(in.) Throwaway 2...16x25x2 I 4...16x16x2 Physical data 48HJ (cont) LEGEND Bhp — Brake Horsepower 'Single phase /three phase. tlndicates automatic reset. "60,000 and 72,000 Btuh heat input units have 2 burners. 90,000 and 120,000 Btuh heat input units have 3 burners. 115,000 Btuh heat input units and 150,000 Btuh Heat input units have 3 burners. ttAn LP kit is available as an accessory. Kit may be used at elevations as high as 2000 ft. If an LP kit is used with Low NOx units, the Low NOx baffle must be removed and the units will no longer be classified as Low NOx units. 120 y IlThree -phase standard models have heating inputs as shown. Single -phase standard models have one -stage heating with heating input values as follows: HJD005 -006,HJE004 — 72,000 Btuh HJE005 -006,HJF004 — 115,000 Btuh HJF005-006 — 150,000 Btuh "'California compliant three -phase models. tttCalifornia SCAQMD compliant low NO models have combustion products that are controlled to 40 nanograms per joule or less. NOTE: Capacities for stainless steel heat exchanger units (S /R/T) are the same as standard units (D /E/F). UNIT STD. LB KG `:CO LB KG W /PRE WEIGHT LB KG CORNER LB WEIGHT KG CORNER LB WEIGHT KG CORNER LB KG CORNER LB WEIGHT KG "J" FT -IN. MM 48HJ.004 530 240 50 22.7 90 40.9 127 57.6 122 55.3 138 62.6 143 64.9 2' -9 5/16" 846.5 48HJ•005 540 245 129 58.5 124 56.2 141 64.0 146 66.2 48HJ.006 560 254 134 60.8 129 58.5 146 66.2 151 68.5 + i 48HJ•007 635 288 f - t 152 68.9 147 66,7 165 74.8 171 77.5 3' -5 5/16' 1050 CONTROL BOX /COMPRESSOR/ BURNER ACCESS PANEL M. O i THREADED EEEE INDOOR FAN MOTOR B BLOWER ACCESS PANEL b CONDUIT SIZE SIZES (MAX.) i 7 /8' ACC. -_ -_- rr ' C J� f-0'-3 (91 . 5/16' [91.0] 1' -2 [376.6] _ = �I g©© o l0 100E BOTTOM POWER CHART, THESE HOLES REO'D FOR USE WITH ACCESSORY PACKAGES - CRBTMPWRDO1A01, 2A01, 3A01, OR 4A01 THREADED WIRE REO'D HOLE CONDUIT SIZE USE SIZES (MAX.) 1/2' ACC. 7/8"[22.2] 1/2' 24V 7/8'[22.2) 3/4' (001,003) POWER. 1 1/8"[28.41 1 1/4' (002 004)POWER. 1 3/4 (003) 1/2 FPT GAS 1 1/4'[31.8] (004) 3/4 'FPT GAS 1 5/8 '[41.31 • - SELECT EITHER 3/4' OR 1 1/4' FOR POWER, DEPENDING ON WIRE SIZE. 48 HJ NOTES, 1. DIMENSIONS IN [ ] ARE IN MILLIMETERS. 2. • CENTER OF GRAVITY. REAR 0 DIRECTION OF AIR FLOW. FILTER /ECONOMIZER ACCESS PANEL 4. ON VERTICAL DISCHARGE UNITS, DUCTWORK TO BE ATTACHED CONDENSER COIL TO ACCESSORY ROOF CURB ONLY. FOR HORIZONTAL DISCHARGE UNITS FIELD SUPPLIED FLANGES SHOULD BE ATTACHED TO HORIZONTAL DISCHARGE OPENINGS, AND ALL DUCTWORK SHOULD BE ATTACHED TO THE FLANGES. CORNER 'A' 2' 7 1/2' 1 3/4' S MINIM PREVAIL). CLEARANCE (LOCAL CODES OR JURISDICTION MAY i (800] d-[45] a. BETWEEN UNIT, FLUE SIDE AND COMBUSTIBLE SURFACES / f T ('�A 36 IN.,18 IN. WHEN USING ACCESSORY FLUE DISCHARGE DEFLTR, / b. BOTTOM OF UNIT TO COMBUSTIBLE SURFACES (WHEN NOT USING LEFT I I CURB) 1 INCH. S I DE ' BOTTOM OF 0E RAIL TO COMBUSTIBLE SURFACES (WHEN NOT I USING SERB) ) 0 INCHES. c. CONDENSER COIL, FOR PROPER AIR FLOW, 36 INCHES �I ONE SIDE, 12 INCHES THE OTHER. THE SIDE GETTING THE GREATER CLEARANCE IS OPTIONAL. M I d. OVERHEAD, 60 INCHES TO ASSURE PROPER CONDENSER FAN 11 OPERATION. 3 -9 I I e. BETWEEN UNITS, CONTROL BOX SIDE, 42 IN. PER NEC. [1144] �2' -0 1/4' / i E F. BETWEEN UNIT AND UNGROUNDED SURFACES, CONTROL BOX SIDE, 36 IN. PER NEC. I [616] / 0' -5 3/4 _ ALT. CONDENSATE g. BETWEEN UNIT AND BLOCK OR CONCRETE WALLS AND OTHER ,] I / [1471-- DRAIN OPENING GROUNDED SURFACES, CONTROL BOX SIDE, 42 IN. PER NEC. I / / IN BASEPAN h. HORIZONTAL SUPPLY AND RETURN END, 0 INCHES WHEN THE ALTERNATE CONDENSATE DRAIN 15 USED. \\ 6. WITH THE EXCEPTION OF THE CLEARANCE FOR THE CONDENSER 1 -9. 0 -1 7/8% fi'o- O' -1 15/16' COIL AND COMBUSTION SIDE AS STATED IN NOTE 450, b, [533] [49] [48.0] AND c, A REMOVABLE FENCE OR BARRICADE REQUIRES NO I ' -11 1/2" 0' -3 5/16" ljc CLEARANCE. I 0' �9 [290] 198.4] 7. UNITS MAY BE INSTALLED ON COMBUSTIBLE FLOORS MADE / 8 FROM WOOD OR CLASS A, B, OR C ROOF COVERING MATERIAL SEE BOTTOM POW R SEE NOTE 48 IF SET ON BASE RAIL. CHART(ELEC. ONLY) _ CORNER - 0" 2' -11 11/16' 0' -3 1/16' B. THE VERTICAL CENTER OF GRAVITY IS l' -6 - [457) UP FROM [906; [79]"' FROM THE BOTTOM OF THE BASE RAIL. [31-O 6 11/16" 0' -3 13/16' [1872] BOTTOM OF UNIT 1' -7 3/16' [487.4 O' -4 9/16' I 3' S 3/16' [115.8] TYP [1046] ) 0' -2 9/16' ELECTRICAL (65) LEFT S IDE D LOCAT ON [97] FACTORY SUPPLIED B FLUE HOOD 1 1' -4 5/16' [414.5] EVAPORATOR COIL r t OUTSIDE AIR 5 + 2' -9 3/8" [848] a 4 5 F/ ECONOMIHERIV AND 0 POWER EXHAUST -e. ' 14] ECONOM I BER IV HOOD 2' -1 11 /16' [652] RETURN AIR OPENING VERTICAL FRONT CORNER 'B 1 1 SUPPLY AIR 1 OPENING I VERTICAL 1 A 1' -5 1/4' [4381 FOR ECONOMIBERIV ■0' -3 3/16' R I GHT S IDE [811 1 \ I SUPPLY AIR OPENING \I I HORIZONTAL I RETURN AIR OPENING HORI- ZONTAL 7' [177.8] 0 1/16' o- [81) I -3 3/16 CORNER 'C' [306] 1' -5 S /16' [439.7] D' -0 3/8' p' -11 7 /B' (301.6] 0' -5 7/16' [138] 0' -5 3/8' 1 [137] FILTER ACCESS PANEL (DISPOSABLE FILTERS) 0' -10 15/16' 4e2E3 RETURN AIR [278] i L0' -2 9/16" [65] i' -5 3/4" SUPPLY AIR (451] ""ff BLOCKOFF PANEL 0 -7 1/4' [184] ' - 10 13/1.' [274.6) A C 0 CONNECTION SIZES 1 3/8' DIA. (35] FIELD POWER SUPPLY HOLE 2" DIA. (51] POWER SUPPLY KNOCK -OUT 1 3/4' DIA. (44] CHARGING PORT HOLE 7 /B' DIA. (22] FIELD CONTROL WIRING HOLE 3/4' 14 NPT CONDENSATE DRAIN 1/2' 14 NPT GAS CONNECTION 2 1/2 DIA. C64] POWER SUPPLY KNOCK -OUT l' -8 1/4' (514] 2' -1 1/16' [652.5] 0' -6 5 /B' [168.2] q L 2[3/8 7 6 ` T 3/"� 2' -1 15/16 0 -B 7/16 .FORK TRUCK SLOTS 0' -5 " / 1464 ] [658.6] (144.3] [214] 0' -2 1/4 "DIA OUT IDE SUPPLY AIR RETURN AIR FRONT (TYP 8 PLACES) OF PANEL RIGHT SIDE E STD. CONDENSATE DRAIN VIEW 5 - 5 1'6 1/2' [470] 0' -0 7/16'[11.1] VERTICAL O' -4 1 /16' ECONOMIBERIV [103.2] W/ POWER EXHAUST FILTER ACCESS PANEL (DISPOSABLE FILTERS) 1' -B 1/4 OUTSIDE AIR 0'- 0 7/8' [22 2] 0 -5 11/16' BAROMETRIC RELIEF DISCHARGE [514] ROOFCURB ACCFSSORY A UNIT SIZE CRRFCURBOOlAO1 1 -2 (356] 48HJ004-007 CRRFCURBOO2A01 2 -0 [610] 48HJ CONNECTOR PKG. ACC CRBTMPWR001 A01 CRBTMPWR002A01 CRBTMPWR003A01 CRBTMPWR004AO1 1' -9 11/16' [551] I I C • C C406] 0 ALT DRAIN HOLE 1 3/4'[44.5] GAS 3/4' 119] NPT 1/2 [12.7)APT 3/4'[19)NPT 0' -0 1/4'[7] POWER 3/4' (19] NPT 1 1/4 [31.7) 3/4'C19)NPT 1 1/4'[31.7] CONTROL 1/2"[12.7]NPT O ACCESSORY PWR 1/2'[12.7)NPY C76) d [ C76) d8 0' -0 7/16' C111 (BOLT HEADS) 1♦ I C I \ / A I % I 1 1 " -1 7/16" 1 C341) B SUPPLY AIR OPENING X 1'-7 13 [504 0' -3' C76] 0' -0 7/16' A I [11] [914) (BOLT HEADS) J 11 A / - rC��--� \ / / / t. RETURN AIR OPENING 1: 334 '1 B' 7 NOTES. 1. ROOFCURB ACCESSORY IS SHIPPED DISASSEMBLED. 2. INSULATED PANELS. 3. DIMENSIONS IN [ ] ARE IN MILLIMETERS. 4. ROOFCURBt GALVANIZED STEEL. S (FLANGESUOII DUCTTRESTRON CURB) 6. SE —DICE CLEARANCE 4 FEET ON EACH SIDE. (FIELD �(J SUPPLIED) 7. DIRECTION OF AIR FLOW. 8. CONNECTOR PACKAGES CRBTMPWROO1A01 AND 2A01 ARE FOR THRU- THE -CURB TYPE GAS. PACKAGES CRBTMPWR003A01 AND 4A01 ARE FOR THE THRU - THE - BOTTOM TYPE GAS CONNECTIONS. 0' - 9/16' [115.5] I I I I I I I 2' -7 5/8" I I C803] I I I I I I I -- - 0 -0 7/16' " REF (BOLT HEADS) A U I SUPPLY AIR RETURN AIR - , VIEW "A -A" HEAD OF BOLT TO BE ON INSIDE OF FLANGE 0' -1 7/8' [48) , - 0 7/16' n VIEW 'B" (BOLT HEADS) A J/ (TYP. ALL CORNERS) GASKET (SUPPLIED WITH CURB) [76) ROOFING FELT (FIELD SUPPLIED) OPENING FOR BASEPAN ENTRY CANT STRIP SERVICE (SEE NOTE .8) (FIELD SUPPLIED] 0' -2 1/2' ROOFING MATERIAL [64) (FIELD SUPPLIED) [152] INSIDE) 3' -0 15/16' [938) 0 (117 1 I RIGID INSULATION I (FIELD SUPPLIED) I I I I GAS SERVICE PLATE (SEE NOTE .8) ∎ • • 11 I • SEE VIEW "8%ad∎ ■ UNIT NAIL TYPICAL (4) SIDES COUNTER FLASHING (FIELD SUPPLIED) 0' -3 1/4' [83] 1 -4 13/16' C427] (INSIDE) 0' -0 1/4' C6.3] 5' -7 1/8' [17051 SECTION - C —C SCALE 1,4 SEE NOTE .2 0' -7 1/16" C179) (INSIDE) NOTES CAMBRIDGEPORT SURE -LOCK' CORNER FASTENING DEVICE 15 ACCEPTABLE ALTERNATE CONSTRUCTION. Te Air Ent Condenser (Edb) Air Entering Evaporator - Cfm/BF 900/0.14 1200/0.17 1500/0.20 Air Entering Evaporator - Ewb (F) 72 67 62 72 67 62 72 67 62 72 TC 41.9 38.7 35.7 43.5 40.8 37.7 44.8 41.8 39.0 75 SHC 20.4 25.2 29.7 21.8 28.2 33.8 23.3 30.7 37.0 35.7 kW 2.19 2.16 2.12 2.21 2.18 2.15 2.23 2.19 2.16 3.53 TC 40.7 37.5 34.5 42.1 39.3 36.4 43.5 40.4 37.6 85 SHC 19.9 24.7 29.2 21.5 27.7 33.2 23.2 30.3 36.4 60.2 kW 2.46 2.42 2.39 2.47 2.44 2.41 2.50 2.45 2.42 52.8 TC 39.3 36.1 33.1 40.8 ' ',37481 34.9 42.0 38.9 36.1 95 SHC 19.5 24.1 28.4 21.1 i27121 32.5 22.8 29.9 35.6 TC kW 2.75 2.71 2.66 2.77 .2:73, 2.69 2.79 2.74 2.71 65.6 TC 37.7 34.6 31.7 39.3 36.2 33.4 40.1 37.2 34.7 105 SHC 18.8 23.5 27.8 20.7 26.6 31.8 22.1 29.3 34.7 L4!45,, kW 3.06 3.02 2.98 3.09 3.04 3.01 3.10 3.06 3.03 57.7 TC 36.0 33.0 29.7 37.4 34.5 31.5 38.1 35.5 33.2 115 SHC 18.3 22.9 26.7 19.9 26.1 30.9 21.3 28.7 33.2 38.4 kW 3.41 3.36 3.31 3.43 3.39 3.34 3.44 3.41 3.37 5.06 TC 34.2 31.3 27.8 35.6 32.7 29.4 36.3 33.6 31.9 125 SHC 17.6 22.2 25.8 19.4 25.4 29.4 20.8 28.0 31.8 31.0 kW 3.78 3.73 3.66 3.80 3.76 3.71 3.81 3.78 3.75 Temp (F) Air Condenser (Edb) Air Entering Evaporator - Cfm/BF 1500/0.08 1750/0.09 2000/0.11 2500/0.13 Air Entering Evaporator - Ewb (F) 72 67 62 72 67 62 72 67 62 72 67 62 TC 70.8 65.4 58.5 72.5 67.3 61.1 73.0 68.4 62.8 74.8 70.3 64.8 75 SHC 34.1 42.7 49.9 35.7 45.5 54.2 36.8 48.0 57.8 39.6 53.0 63.4 kW 3.53 3.49 3.44 3.55 3.50 3.46 3.55 3.51 3.47 3.57 3.54 3.48 TC 68.9 63.2 55.3 70.5 65.1 57.9 72.2 66.4 60.2 73.2 68.1 62.9 85 SHC 33.5 41.8 48.4 35.0 44.8 52.8 37.0 47.6 56.8 39.3 52.5 62.4 kW 3.98 3.94 3.87 4.00 3.96 3.90 4.03 3.97 3.92 4.04 3.99 3.94 TC 66.8 60.6 52.4 68.3 ' 62:5 54.3 69.3 63.8 56.6 71.2 65.6 60.6 95 SHC 32.8 40.7 47.0 34.5 43:8 51.1 36.0 46.7 55.0 39.1 51.8 60.5 kW 4.48 4.43 4.35 4.50 L4!45,, 4.37 4.51 4.46 4.40 4.55 4.48 4.44 TC 64.3 57.7 49.9 65.9 59.8 51.7 66.9 61.1 54.1 68.4 62.8 58.4 105 SHC 32.0 39.6 45.8 33.7 42.8 49.7 35.3 45.7 53.5 38.4 51.0 58.4 kW 5.03 4.96 4.87 5.05 4.99 4.90 5.06 5.00 4.93 5.08 5.02 4.98 TC 61.5 54.8 47.3 62.8 56.7 49.1 64.0 58.2 51.6 65.4 59.9 56.1 115 SHC 31.0 38.4 44.5 32.5 41.6 48.2 34.4 44.6 51.6 37.4 50.0 56.1 kW 5.61 5.55 5.46 5.62 5.58 5.49 5.65 5.60 5.52 5.67 5.61 5.57 TC 58.7 51.6 44.5 59.9 53.4 46.2 60.8 54.9 49.0 62.2 56.8 53.5 125 SHC 30.0 37.2 43.1 31.7 40.4 46.2 33.3 43.4 48.9 36.4 48.9 53.4 kW 6.27 6.19 6.09 6.28 6.21 6.13 6.29 6.24 6.17 6.31 6.27 6.22 Performance data 48HJ 48HJ004 (3 TONS) Temp (F) Air Ent Condenser (Edb) 75 85 95 105 115 125 48HJ006 (5 TONS) COOLING CAPACITIES - STANDARD UNITS bdb = tedb TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW 72 54.0 26.1 2.81 52.2 25.4 3.20 50.7 24.9 3.64 48.8 24.3 4.12 46.5 23.4 4.64 43.8 22.5 5.19 67 50.7 32.7 2.80 48.9 32.0 3.19 46.9 31.1 3.61 44.5 30.2 4.09 41.1 28.9 4.59 37.5 27.4 5.13 62 44.2 37.5 2.76 41.9 36.4 3.15 39.5 35.0 3.57 36.7 33.6 4.03 34.3 32.4 4.53 32.4 31.5 5.05 Air Entering Evaporator - Cfm/BF Air Entering Evaporator - Ewb (F) 72 55.9 27.6 2.83 54.1 26.9 3.22 51.9 26.1 3.65 49.8 25.3 4.12 47.7 24.9 4.65 45.1 24.1 5.20 67 52.2 35.1 2.81 50.4 34.5 3.20 ` 33 X3:62,1 46.2 32.8 4.09 43.3 31.8 4.62 39.0 30.2 5.15 62 47.7 41.8 2.78 45.9 40.8 3.17 43.5 39.6 3.60 40.7 38.2 4.06 37.0 36.3 4.55 33.8 33.7 5.09 72 56.4 28.2 2.83 54.5 27.5 3.22 52.5 26.8 3.65 50.2 26.0 4.12 48.0 25.4 4.64 45.3 24.7 5.19 67 52.8 36.2 2.80 51.0 35.7 3.20 48.9 34.7 3.62 46.7 33.9 4.09 44.4 33.4 4.63 40.1 31.9 5.17 62 49.1 43.8 2.79 47.2 42.8 3.18 45.2 41.8 3.60 42.1 40.3 4.07 38.5 38.3 4.56 35.4 35.4 5.11 72 58.1 30.2 2.84 55.3 28.6 3.22 53.9 28.8 3.67 51.5 27.9 4.14 48.9 27.1 4.65 46.3 26.5 5.20 67 54.5 39.5 2.82 52.3 38.5 3.20 50.1 37.5 3.63 48.2 37.4 4.11 45.7 36.9 4.63 42.6 35.9 5.19 1200/0.17 1450/0.19 1600/0.21 2000/0.24 Standard Ratings LEGEND BF - Bypass Factor Edb - Entering Dry Bulb Ewb - Entering Wet Bulb kW - Compressor Motor Power Input SHC - Sensible Heat Capacity (1000 Btuh) Gross TC - Total Capacity (1000 Btuh) Gross NOTES: 1. Direct interpolation is permissible. Do not extrapolate. 2. The following formulas may be used: sensible capacity (Btuh) 1.10xcfm thwb = Wet -bulb temperature corresponding to enthalpy of air leaving evaporator coil (hn.th) hnvb = he,„b total capacity (Btuh) 4.5 x cfm Where: h.b = Enthalpy of air entering evaporator coil. 3. The SHC is based on 80 F edb temperature of air entering evapo- rator coil. Below 80 F edb, subtract (corr factor x cfm) from SHC. Above 80 F edb, add (corn factor x cfm) to SHC. Correction Factor = 1.10 x (1 - BF) x (edb - 80). 62 50.6 47.5 2.79 48.7 46.6 3.18 46.7 45.6 3.61 44.7 44.4 4.08 42.0 42.0 4.60 38.8 38.8 5.15 147 0o 48HJ005 (4 TONS) - STANDARD MOTOR (BELT DRIVE)' Airflow (Cfm) 1200 1300 1400 1500 1600 1700 1800 1900 2000 48HJ005 (4 TONS) - STANDARD MOTOR (BELT DRIVE Airflow (Cfm) 1200 1300 1400 1500 1600 1700 1800 1900 2000 48HJ005 (4 TONS) - HIGH- STATIC MOTOR (BELT DRIVE)' Airflow (Cfm) 1200 1300 1400 1500 1600 1700 1800 1900 2000 48HJ005 (4 TONS) - HIGH- STATIC MOTOR (BELT DRIVE)' (cont) Airflow (Cfm) 1200 1300 1400 1500 1600 1700 1800 1900 2000 FAN PERFORMANCE - VERTICAL DISCHARGE UNITS (cont) ) (cont) LEGEND Bhp - Brake Horsepower Watts - Input Watts to Motor 'Motor drive range: 770 to 1185 rpm. All other rpms require field - supplied drive. LEGEND Bhp - Brake Horsepower Watts - Input Watts to Motor *Motor drive range: 1075 to 1455 rpm. All other rpms require field - supplied drive. Refer to page 188 for general Fan Performance Data notes. NOTES: 1. Boldface indicates field- supplied drive is required. 2. Maximum continuous bhp is 1.20. Refer to page 188 for general Fan Performance Data notes. NOTES: 1. Boldface indicates field- supplied drive is required. 2. Maximum continuous bhp is 2.40. 0.2 Rpm 666 701 737 773 810 847 885 923 962 Bhp 0.26 0.31 0.36 0.42 0.49 0.57 0.66 0.75 0.85 Watts 257 306 361 422 491 567 652 745 847 0.4 Rpm 778 810 842 875 909 943 978 1014 1049 Bhp 0.37 0.43 0.49 0.57 0.65 0.73 0.83 0.94 1.05 Watts 367 426 491 564 643 730 826 930 1043 External Static Pressure (in. wg) 0.6 Rpm 871 901 931 963 994 1027 1060 1093 Bhp 0.47 0.54 0.62 0.70 0.79 0.89 1.00 1.11 Watts 471 540 616 699 790 888 994 1109 0.8 Rpm 952 981 1010 1040 1070 1101 1133 Bhp 0.57 0.65 0.74 0.84 0.94 1.05 1.16 Watts 572 651 738 831 932 1040 1157 Rpm 1025 1053 1081 1110 1140 1170 1.0 Bhp 0.67 0.76 0.86 0.96 1.08 1.20 Watts 670 760 856 960 1070 1189 1.2 Rpm 1093 1119 1147 1175 Bhp 0.77 0.87 0.98 1.09 Watts 767 866 972 1086 1.4 Rpm 1155 1181 1208 Bhp 0.87 0.98 1.09 Watts 861 970 1086 External Static Pressure (in. wg) 1.6 Rpm 1213 1239 Bhp 0.96 1.08 Watts 955 1073 1.8 Rpm 1268 1294 Bhp 1.05 1.18 Watts 1047 1175 Rpm 1321 2.0 Bhp 1.14 Watts 1137 0.2 Rpm 666 701 737 773 810 847 885 923 962 Bhp 0.26 0.31 0.36 0.42 0.49 0.57 0.66 0.75 0.85 Watts 257 306 361 422 491 567 652 745 847 0.4 Rpm 778 810 842 875 909 943 978 1014 1049 Bhp 0.37 0.43 0.49 0.57 0.65 0.73 0.83 0.94 1.05 Watts 367 426 491 564 643 730 826 930 1043 External Static Pressure (In. wg) 0.6 Rpm 871 901 931 963 994 1027 1060 1093 1127 Bhp 0.47 0.54 0.62 0.70 0.79 0.89 1.00 1.11 1.24 Watts 471 540 616 699 790 888 994 1109 1233 0.8 Rpm 952 981 1010 1040 1070 1101 1133 1165 1198 Bhp 0.57 0.65 0.74 0.84 0.94 1.05 1.16 1.29 1.42 Watts 572 651 738 831 932 1040 1157 1283 1417 Rpm 1025 1053 1081 1110 1140 1170 1200 1231 1263 1.0 Bhp 0.67 0.76 0.86 0.96 1.08 1.20 1.32 1.46 1.61 Watts 670 760 856 960 1070 1189 1316 1453 1598 1.2 Rpm 1093 1119 1147 1175 1204 1233 1262 1293 1323 Bhp 0.77 0.87 0.98 1.09 1.21 1.34 1.48 1.63 1.79 Watts 767 866 972 1086 1207 1336 1473 1620 1776 1.4 Rpm 1155 1181 1208 1235 1263 1292 1321 1350 1380 Bhp 0.87 0.98 1.09 1.22 1.35 1.49 1.64 1.79 1.96 Watts 861 970 1086 1209 1340 1480 1627 1784 1950 External Static Pressure (in. wg) 1.6 Rpm 1213 1239 1265 1292 1320 1348 1376 1405 1434 Bhp 0.96 1.08 1.21 1.34 1.48 1.63 1.79 1.96 2.13. Watts 955 1073 1199 1332 1472 1622 1779 1946 2123 1.8 Rpm 1268 1294 1320 1346 1373 1401 1428 1457 1486 Bhp 1.05 1.18 1.32 1.46 1.61 1.77 1.94 2.12 2.31 Watts 1047 1175 1310 1452 1603 1762 1930 2106 2293 Rpm 1321 1346 1371 1397 1424 1451 1479 . 1506 2.0 Bhp 1.14 1.28 1.43 1.58 1.74 1.91 2.09 2.28 Watts 1137 1275 1419 1572 1732 1901 2078 2265 165 UNIT 48HJ UNIT PHASE MAXIMUM CONTINUOUS BHP* MAXIMUM OPERATING WATTS` UNIT VOLTAGE MAXIMUM AMP DRAW 004 Single 1.20 1000 208/230 4.9 Three 1.20 1000 208/230 4.9 460 2.2 2120 ` 575 2.2 005 Single 1.20 1000 208/230 4.9 Three 1.20 1000 208/230 4.9 460 2.2 575 2.2 006 Single 1.30 1650 208/230 10.1 Three 2.40 2120 208/230 6.7 460 3.0 575 3.0 007 Three 2.40 2120 208/230 6.7 460 3.0 575 3.0 008,009 Three 2.90 2615 208/230 8.6 460 3.9 575 3.9 012 Three 3.70 3775 208/230 12.2 460 5.5 575 5.5 014 Three 5.25 4400 208/230 17.3 460 8.5 575 8.5 UNIT 48HJ UNIT PHASE MAXIMUM CONTINUOUS BHP' MAXIMUM OPERATING WATTS* UNIT VOLTAGE MAXIMUM AMP DRAW 004 Three 2.40 2120 208/230 6.7 460 3.0 575 3.0 005 Three 2.40 2120 208/230 6.7 460 3.0 575 3.0 006 Three 2.90 2615 208/230 8.6 460 3.9 575 3.9 007 Three 2.90 2615 208/230 8.6 460 3.9 575 3.9 008,009 Three 4.20 3775 208/230 12.2 460 5.5 575 5.5 012 Three 5.25 4400 208/230 17.3 460 8.5 575 8.5 Performance data 48HJ (cont) LEGEND Bhp - Brake Horsepower 'Extensive motor and electrical testing on these units ensures that the full horsepower and watts range of the motors can be utilized with confidence. Using the fan motors up to the ratings shown in this table will not result in nuisance tripping or premature motor failure. Unit warranty will not be affected. 212 EVAPORATOR -FAN MOTOR PERFORMANCE - STANDARD MOTOR - 48HJ004 -014 EVAPORATOR -FAN MOTOR PERFORMANCE - HIGH - STATIC MOTORS - 48HJ004 -014 LEGEND Bhp - Brake Horsepower *Extensive motor and electrical testing on these units ensures that the full horsepower and watts range of the motors can be utilized with confidence. Using the fan motors up to the ratings shown in this table will not result in nuisance tripping or premature motor failure. Unit warranty will not be affected. UNIT 48HJ ARI RATING (decibels) A- WEIGHTED (db) OCTAVE BANDS 63 125 250 500 1000 2000 4000 8000 004,005 76 76.0 55.9 66.0 64.0 66.2 68.4 64.5 61.7 57.3 006,007 80 80.0 59.1 68.9 68.7 71.9 74.0 68.9 65.7 59.0 008,009 82 82.0 62.2 69.3 71.5 74.7 76.2 72.9 68.7 61.5 012 84 84.0 64.6 71.1 73.3 76.9 77.6 73.7 70.6 63.7 014 86 86.0 63.7 69.9 72.5 78.2 81.1 77.3 73.3 66.8 015,017 88 87.6 90.8 88.7 86.4 84.3 83.5 78.4 75.6 66.8 020 -024 82 81.7 90.2 84.8 80.7 79.0 77.6 71.4 66.7 60.7 028 85 84.9 90.0 86.3 83.6 82.9 80.3 74.9 71.4 66.5 FAN PERFORMANCE USING ACCESSORY POWER EXHAUST (48HJ015,017) 0.3 0.2 - 0.1- 3500 4000 4500 CFM 5000 OUTDOOR SOUND POWER (TOTAL UNIT) LEGEND ARI - Air Conditioning and Refrigeration Institute NOTE: Indoor sound power is available in Carrier's Electronic Catalog Program (ECAT) for specific operating parameters. (1,10), 219 00 2 U NIT U H T NOMINAL VOLTAGE (V-Ph-Hz) VOLTAGE RANGE COMPRESSOR (each OFM (each) IFM COMBUSTION FAN MOTOR POWER SUPPLY' MINIMUM UNIT DISCONNECT SIZEt Min Max Qty RLA LRA FLA FLA FLA MCA MOCP" FLA LRA 004 (3 Tons) 208/230 -1 -60 187 254 1 16.0 88.0 0.7 4.9 .60 25.6/25.6 30/30 25/25 101/101 208/230 -3-60 187 254 10.3 77.0 0.7 4.9 .60 18.5/18.5 25/25 18/18 90/90 460 -3-60 414 508 5.1 39.0 0.4 2.2 .30 9.0 20 9 46 575 -3-60 518 632 42 31.0 0.4 22 .30 7.3 20 7 37 005 • (4 Tons) - 208/230 -1 -60 187 254 1 23.7 126.0 0.7 4.9 .60 35.2/35.2 45/45 34/34 139/139 208/230 -3-60 187 254 13.5 93.0 0.7 4.9 .60 22.5/22.5 30/30 22/22 106/106 460 -3-60 414 508 6.4 46.5 0.4 2.2 .30 10.6 20 10 54 575 -3-60 518 632 6.4 40.0 0.4 2.2 .30 10.1 20 10 46 006 (5 Tons) 208/230 -1 -60 187 254 1 28.8 169.0 1.5 8.8 .60 46.3/46.3 60 /60 45/45 216/216 208/230 -3-60 187 254 17.3 123.0 1.5 5.8 .60 28.9/28.9 35/35 28/28 168/168 460 -3-60 414 508 9.0 62.0 0.8 2.6 .30 14.7 20 14 84 575 -3-60 518 632 7.1 50.0 0.8 2.6 .30 11.6 20 11 68 007 (6 Tons) 208/230 -3-60 187 254 1 20.5 156.0 1.4 5.8 .60 32.8/32.8 40/40 32/32 200/200 460 -3-60 414 508 9.6 75.0 0.6 2.6 .30 15.2 20 15 97 575 -3-60 518 632 7.7 56.0 0.6 2.6 .30 12.2 20 12 74 008 (7'/2 Tons) 208/230 -3-60 187 254 2 12.4 88.0 1.4 7.5 .60 38.2/38.2 45/45 40/40 242/242 460-3-60 414 508 6.4 44.0 0.7 3.4 .30 19.2 25 20 121 575 -3-60 518 632 4.8 34.0 0.7 3.4 .30 14.6 20 15 95 009 (81/2 Tons) 208/230 -3-60 187 254 2 13.4 105.0 1.4 7.5 .60 40.2/40.2 45/45 42/42 276/276 460-3-60 414 508 7.4 55.0 0.7 3.4 .30 21.5 25 23 143 575 -3-60 518 632 6.4 44.0 0.7 3.4 .30 18.2 20 19 115 012 (10 Tons) 208/230 -3-60 187 254 2 17.6 125.0 1.4 10.6 .60 53/53 60 /60 56/56 341/341 460 -3-60 414 508 8.3 62.5 0.7 4.8 .30 24.9 30 26 171 575 -3 -60 518 632 6.3 50.0 0.7 4.8 .30 19.1 25 20 136 014 (12 Tons) 208/230 -3-60 187 254 2 19.0 156.0 1.4 15.0 .60 60.6/60.6 70/70tt 64/64 426/426 460 -3 -60 414 508 9.0 75.0 0.7 7.4 .30 29.1 35 31 207 575 -3-60 518 632 7.4 54.0 0.7 7.4 .30 23.7 30 25 154 POWER EXHAUST PART NO. MCA (230 v) MCA (460 v) MCA (575 v) MOCP (for separate power source) CRPWREXH021A01 N/A 0.68 N/A 15 CRPWREXH022A01 3.4 N/A 1.32 15 CRPWREXH023A01 N/A 1.4 N/A 15 CRPWREXH028A01 1.7 N/A 0.68 15 CRPWREXH029A01 N/A 0.7 N/A 15 CRPWREXH030A01 1.6 N/A 0.64 15 Electrical data 48HJ LEGEND FLA - Full Load Amps HACR - Heating, ir Conditioning and Refrigeration IFM - Indoor (Evaporator) Fan Motor LRA - Locked Rotor Amps MCA - Minimum Circuit Amps MOCP - Maximum Overcurrent Protection NEC - National Electrical Code OFM - Outdoor (Condenser) Fan Motor RLA - Rated Load Amps UL - Underwriters' Laboratories 48HJ004 -014 STANDARD MOTOR UNITS (WITHOUT ELECTRICAL CONVENIENCE OUTLET) The values listed in this table do not include power exhaust. See table at right for power exhaust requirements. tUsed to determine minimum disconnect per NEC. **Fuse or HACR circuit breaker. ttFuse only. NOTES: 1. In compliance with NEC requirements for multimotor and combination load equipment (refer to NEC Articles 430 and 440), the overcurrent protective device for the unit shall be fuse or HACR breaker. The UL, Canada units may be fuse or circuit breaker. 2. Electrical data based on 95 F ambient outdoor -air temperature * 10% voltage. 3. Unbalanced 3 -Phase Supply Voltage Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use the following formula to determine the percent of voltage imbalance. 220 = 100 x max voltage deviation from average voltage average voltage Example: Supply voltage is 460 -3-60. A B c AB = 452 v BC =464v AC = 455 v Average Voltage = 452 + 464 + 455 3 1371 3 = 457 Determine maximum deviation from average voltage. AB) 457- 452 =5v BC) 464 - 457 = 7 v AC) 457 - 455 = 2 v US Maximum deviation is 7 v. Determine percent of voltage imbalance. % Voltage Imbalance = 100 x 457 = 1.53% POWER EXHAUST ELECTRICAL DATA This amount of phase imbalance is satisfactory as it is below the maximum allowable 2 %. IMPORTANT: If the supply voltage phase imbalance is more than 2 %, contact your local electric utility company immediately. N/A - Not available NOTE: If a single power source is to be used, size wire to include power exhaust MCA and MOCP. Check MCA and MOCP when power exhaust is powered through the unit. Determine the new MCA including the power exhaust using the following formula: MCA New = MCA unit only + MCA of Power Exhaust For example, using a 48HJD006 - - -5 unit with MCA = 28.9 and MOCP = 35, with CRPWREXH030A01 power exhaust. MCA New = 28.9 amps + 1.6 amps = 30.5 amps If the new MCA does not exceed the published MOCP, then MOCP would not change. The MOCP in this example is 35 amps and the MCA New is below 35; therefore the MOCP is acceptable. If "MCA New" is larger than the published MOCP, raise the MOCP to the next larger size. For separate power, the MOCP for the power exhaust will be 15 amps per NEC. Load Express: Load Calculation Software Load Express: Load Calculation Software By: Seattle Mechanical General Job r �4 Job Description: Building Owner: Program User: Comments: Program was Run: Dataset Name: gwn 109 Seattle Mechanical 10/21/200.tt 2:40:33 PM C: \CDS \LOADEXP \DATA \STE 109.LE • Alternative 1 Alt1 Geographical Data Location: Weather File: Latitude: Elevation: Seattle, Washington Seattle, Washington 47 deg 386 ft Design Data Summer Dsn Dry Bult Summer Dsn Wet Bul Winter Design Dry Bu Density -Sp Heat Prod Design Simulation per MO92 FELE COPY 80.0 deg F 64.0 deg F 26.0 deg F 1.0988 Btu - min /(hr -ft3 -F) Apr To Nov • KKVIEWVtD FUR CODE COMPLIANCE APPROVED NOV 14 2008 Of Tukwila ItDIN D SIION Version 2.2 Title Page Building Peak Data Month /Hour: Jul Cooling Capacity: 48.2 Cooling Sensible: 38.9 Sensible Heat Ratio (SH Heating Capacity -55.4 / 15 Mbh Mbh 0.887 Mbh RECEWED OCT 2920 PERMIT CENTER Load Express: Load Calculation Software Version 2.2 Zone /Air Handler Descriptions Alternative - 1 Alt1 Zone /Air Handler Descriptions Air Handler Type Description 1 CONSTANT AHU1 Zone Type Description 1 Commercial Retail Zone1 Load Express: Load Calculation Software Alternative 1 Alt1 General Job Data Weather Location: Seattle, Washington Weather Region: Northwest Clg Simulation Start Month: Apr Clg Simulation End Month: Nov Zone Data Alternative Number: 1 Zone Number: 1 Floor Width: 74 ft Floor Length: 18 ft Ceiling Height: 10 ft Fir-to-Fir Height: 24 ft No. of Dup Zones: 1 Ceiling U- Factor: 0.05 Btu /(hr- F -ft2) Floor Calculation Type: Slab -On -Grade Floor Loss Coefficient: 0.73 Btu /(hr -F -ft) Floor Perimeter Length186.00 ft W H ft ft ROOF 1 74 x 18 PART 1 75 x 10 PART 2 75 x 10 PART 3 18 x 10 PART 4 18 x 10 Type Steel Deck, 5" Ins Frame, 0.75" gypsum board Frame, 0.75" gypsum board Frame, 0.75" gypsum board Frame, 0.75" gypsum board 1 -2 Story Office Building Opening Time: 8 am Building Closing Time: 6 pm Building Direction: 0 Clg Sensible SF: 10.00 Cooling Dry Bulb: Relative Humidity: Heating Dry Bulb: People Density: People Activity: People Sensible Load: People Latent Load: Misc. Equip. Type: Misc. Equip. Sensible Load Misc. Equip. Latent Load: Misc. Equip. Sensible to RV Lighting Intensity: Lighting Type: ecessed fluorescent, not vented 0.05 Light 0.39 0.39 0.39 0.39 0 RA 72 deg F 50 % 70 deg F 100 ft2 /pers General Office Space 210 Btuh /pers 255 Btuh /pers Microcomputers 350.00 Watt/pers 0.00 Watt/ft2 0 Btuh 1.20 Watt/ft2 North No 0 0 0 0 0 0 80 80 80 80 Clg Latent SF: 10 Htg Sensible SF: 10 People Diversity: 100 % Bldg Simulation Type: Cooling and Heating Ballast Factor: 1.00 % Percent Light to RA: 0 % Vent Type: General Office Space Vent Cool Design: 20.00 cfm /pers Vent Heat Design: 20.00 cfm /pers Supply Cool Design: 0 cfm Supply Heat Design: 0 cfm Infiltration Type: Pressurized, Average Construction Infilt. Cooling Desigi 0.30 ach /hr Infilt. Heating Desigi 0.30 ach /hr Room Exhaust: 0.00 cfm U- Factor Color Percent ( %) Direction Susp Ceil Tilt Cool Adj Heat Adj Dimension % Glass Shading Coeff Spc Temp Spc Temp deg F deg F 0 45 45 45 45 0.00 0.00 0.00 0.00 0.00 Version 2.2 Zone Input Data Shading Load Express: Load Calculation Software Air Handler Input Alternative 1 Air Handler 1 Fan Configuration: Fan & Motor Efficiency: Cooling Supply Air Temp: Heating Supply Air Temp: Minimum Relative Humidity: Supply Fan Static Pressure: Return Fan Static Pressure: CONSTANT AHU1 Draw 56.00 % 55.00 deg F 0.00 deg F 40 % 2.50 in H2O 2.00 in H2O Supply Duct Location: Supply Duct Insulation: Supply Duct Temp Rise: Return Duct Insulation: Return Duct Temp Rise: Terminal Type: Total Cool Airflow: Total Heat Airflow: Zone(s) Connected: Return Air R4 Duct Insulation 0.3 deg F TD R4 Duct Insulation 0.3 deg F TD CONSTANT 0 cfm 0 cfm 1 Load Express: Load Calculation Software versio2.2 Peak Load Information Alternative 1 Design Heating: Airflow (cfm) Space Total Heating Coil Total Outside % O.A Sensible Sensible Entering Leaving Humidification Air Handler ft/Type Btuh Btuh DB DB Btuh BLDG BLOCK - 33,403.40 - 55,435.80 - 7,149.5 BLDG PEAK - 33,403.40 - 55,435.80 - 7,149.5 1 CONSTANT 1,829.51 266.40 14.56 - 33,403.40 - 55,435.80 62.95 86.62 - 7,149.5 Design Cooling: Airflow (cfm) Cooling Cooling Coil Total Outside % OA Total Sensible S.H.R. Entering Leaving ft2/ton cfm/ton cfml t2 Total Air Handler #/Type Btuh Btuh DB WB DB WB tons BLDG BLOCK 48,215.70 42,784.70 0.89 331.51 4.0 BLDG PEAK 48,215.70 42,784.70 0.89 331.51 4.0 1 CONSTANT 1,829.51 266.40 14.56 48,215.70 42,784.70 0.89 74.63 60.72 53.07 51.32 331.51 455.3 1.4 4.0 Building Peak Load Components Mo/Hr: Bldg 7/15 Air Hand 1 7/15 Zone 1 7/15 Solar Cooling (Btuh) Heating (Btuh) Cond Internal OA+Inf Misc Total Cond OA +Inf Misc Total 7,676.6 25,830.9 4,467.9 5,857.0 43,832.4 - 27,146.8 - 16,099.9 - 7,149.5 - 50,396.2 7,676.6 25,830.9 4,467.9 5,857.0 43,832.4 - 27,146.8 - 16,099.9 - 7,149.5 - 50,396.2 7,676.6 25,830.9 4,467.9 5,857.0 43,832.4 - 27,146.8 - 16,099.9 - 7,149.5 - 50,396.2 Load Express: Load Calculation Software Psychrometric State Points - Alternative 1 AIt1 Zone 1 Dry Bulb Wet Bulb Temp Diff. Zone1 ( deg F ) ( deg F ) ( deg F ) Space 72.0 59.5 Zone Return Air Heat Pickup 0.3 Return Fan 1.3 Return Air 73.6 60.1 Outdoor Air 80.0 64.0 Return /Outdoor Air Mix 74.6 60.7 Blow Through Fan 0.0 Entering Coil 74.6 60.7 Leaving Coil 53.1 51.3 Draw Through Fan 1.6 Supply Duct Heat Gain 0.3 Supply Air 55.0 52.1 Percent Outside Air Space Sensible Heat Ratio (SHR) Coil Airflow 16.02 % 0.900 1,663 cfm Version 2.2 Psychrometrics Load Express: Load Calculation Software Sensible Load Profile (Mbh) Alternative 1 Alt1 Version 2.2 Sensible Load Profile Hour 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Air Hand 1 10 9 9 8 8 8 8 27 29 31 34 35 37 38 39 39 39 38 18 16 14 13 12 11 Bldg 10 9 9 8 8 8 8 27 29 31 34 35 37 38 39 39 39 38 18 16 14 13 12 11 Zone 1 10 9 9 8 8 8 8 27 29 31 34 35 37 38 39 39 39 38 18 16 14 13 12 11 Load Express: Load Calculation Software Peak Load Summary - Alternative 1 Air Hand 1 AHU1 Areas ( ft2 ) Floor: SlabOnG /ExFIr: Roof: Skylight: Wall: Wall Glass: Partition: 1,332.0 186.0 1,332.0 0.0 0.0 0.0 1,860.0 Alt1 Space Sens Load Spc Sens Ld W /Sfty Fctr Cool Airflow Cool Airflw W /Sfty Fctor Cooling Check Cool Check W /Sfty Fctr Heat Airflow Heat Airfiw W /Sfty Fctr 31,068.3 Btuh 34,175.2 Btuh 1,663 cfm 1,830 cfm 1.25 cfm /ft2 1.37 cfm /ft2 1,663 cfm 1,830 cfm Version 2.2 Peak Load Summary Heating Coil Peak Outside Air: OADB: 26 Cooling Coil Peak Peaked at Time: Mo /Hr: 7 / 15 Outside Air: OADB: 80 WB: 64 RELHUM: 41.8% Cooling Coil Peak Heating Coil Peak Total Load Sens Load Percnt of Tot Peak Tot Sens Percnt of Tot ( Btuh) ( Btuh ) ( %) ( Btuh) ( %) ENVELOPE LOADS Solar Skylight Solar 0.00 0.00 0.00 Glass Solar 0.00 0.00 0.00 Sub Total 0.00 0.00 0.00 0.00 0.00 Conducted Skylight 0.00 0.00 0.00 Roof 1,932.93 1,932.93 - 3,223.44 Glass 0.00 0.00 0.00 Wall 0.00 0.00 0.00 Partition 5,743.68 5,743.68 - 17,949.00 SlabOnG /ExFIr 0.00 0.00 - 5,974.32 Sub Total 7,676.61 7,676.61 17.51 - 27,146.80 53.87 INTERNAL LOADS Lights 5,003.57 5,003.57 0.00 People 6,002.74 2,606.14 0.00 Misc 14,824.60 14,824.60 0.00 Sub Total 25,830.90 22,434.30 58.93 0.00 0.00 MISC LOADS Outside Air 3,574.36 2,341.81 - 12,879.90 Humidification 0.00 0.00 - 7,149.52 Infiltration 893.59 585.45 - 3,219.99 Sup. Fan Heat 2,969.98 2,969.98 0.00 Ret. Fan Heat 2,375.99 2,375.99 0.00 Duct Heat Pkup 1,096.53 1,096.53 0.00 Exhaust Heat - 585.49 - 585.49 0.00 Sub Total 10,325.00 8,784.27 23.56 - 23,249.40 46.13 OV /UNDR Sizing 0.00 0.00 0.00 Grand Total 43,832.40 38,895.10 - 50,396.20 W /Safety Factor 48,215.70 42,784.70 - 55,435.80 Load Express: Load Calculation Software Peak Load Summary - Alternative 1 Air Hand 1 AHU1 Areas ( ft2 ) Floor: SlabOnG /ExFIr: Roof: Skylight: Wall: Wall Glass: Partition: 1,332.0 186.0 1,332.0 0.0 0.0 0.0 1,860.0 Alt1 Space Sens Load Spc Sens Ld W /Sfty Fctr Cool Airflow Cool Airflw W /Sfty Fctor Cooling Check Cool Check W /Sfty Fctr Heat Airflow Heat Airfiw W /Sfty Fctr 31,068.3 Btuh 34,175.2 Btuh 1,663 cfm 1,830 cfm 1.25 cfm /ft2 1.37 cfm /ft2 1,663 cfm 1,830 cfm Version 2.2 Peak Load Summary Heating Coil Peak Outside Air: OADB: 26 Cooling Coil Peak Peaked at Time: Mo /Hr: 7 / 15 Outside Air: OADB: 80 WB: 64 RELHUM: 41.8% Load Express: Load Calculation Software Version 2.2 Peak Load Summary Peak Load Summary - Alternative 1 Alt1 Bldg 1 Areas ( ft2 ) Floor: 1,332.0 SlabOnG /ExFIr: 186.0 Roof: 1,332.0 Skylight: 0.0 Wall: 0.0 Wall Glass: 0.0 Partition: 1,860.0 Heating Coil Peak Outside Air: OADB: 26 Cooling Coil Peak Peaked at Time: Mo /Hr: 7 / 15 Outside Air: OADB: 80 WB: 64 RELHUM: 41.8% Cooling Coil Peak Heating Coil Peak Total Load Sens Load Percnt of Tot Peak Tot Sens Percnt of Tot ( Btuh) ( Btuh ) (%) ( Btuh) ( %) ENVELOPE LOADS Solar Skylight Solar 0.00 0.00 0.00 Glass Solar 0.00 0.00 0.00 Sub Total 0.00 0.00 0.00 0.00 0.00 Conducted Skylight 0.00 0.00 0.00 Roof 1,932.93 1,932.93 - 3,223.44 Glass 0.00 0.00 0.00 Wall 0.00 0.00 0.00 Partition 5,743.68 5,743.68 - 17,949.00 SlabOnG / ExFlr 0.00 0.00 - 5,974.32 Sub Total 7,676.61 7,676.61 17.51 - 27,146.80 53.87 INTERNAL LOADS Lights 5,003.57 5,003.57 0.00 People 6,002.74 2,606.14 0.00 Misc 14,824.60 14,824.60 0.00 Sub Total 25,830.90 22,434.30 58.93 0.00 0.00 MISC LOADS Outside Air 3,574.36 2,341.81 - 12,879.90 Humidification 0.00 0.00 - 7,149.52 Infiltration 893.59 585.45 - 3,219.99 Sup. Fan Heat 2,969.98 2,969.98 0.00 Ret. Fan Heat 2,375.99 2,375.99 0.00 Duct Heat Pkup 1,096.53 1,096.53 0.00 Exhaust Heat - 585.49 - 585.49 0.00 Sub Total 10,325.00 8,784.27 23.56 - 23,249.40 46.13 OV /UNDR Sizing 0.00 0.00 0.00 Grand Total 43,832.40 38,895.10 - 50,396.20 W /Safety Factor 48,215.70 42,784.70 - 55,435.80 Load Express: Load Calculation Software Version 2.2 Peak Load Summary Peak Load Summary - Alternative 1 Alt1 Bldg 1 Areas ( ft2 ) Floor: 1,332.0 SlabOnG /ExFIr: 186.0 Roof: 1,332.0 Skylight: 0.0 Wall: 0.0 Wall Glass: 0.0 Partition: 1,860.0 Heating Coil Peak Outside Air: OADB: 26 Cooling Coil Peak Peaked at Time: Mo /Hr: 7 / 15 Outside Air: OADB: 80 WB: 64 RELHUM: 41.8% ' Load Express: Load Calculation Software Peak Load Summary - Alternative 1 Zone 1 Zone1 Areas ( ft2 ) Floor: SlabOnG /ExFIr: Roof: Skylight: Wall: Wall Glass: Partition: 1,332.0 186.0 1,332.0 0.0 0.0 0.0 1,860.0 Alt1 Space Sens Load Spc Sens Ld W /Sfty Fctr Cool Airflow Cool Airflw W /Sfty Fctor Cooling Check Cool Check W /Sfty Fctr Heat Airflow Heat Airflw W /Sfty Fctr 31,068.3 Btuh 34,175.2 Btuh 1,663 cfm 1,830 cfm 1.25 cfm /ft2 1.37 cfm /ft2 1,663 cfm 1,830 cfm Version 2.2 Peak Load Summary Heating Coil Peak Outside Air: OADB: 26 Cooling Coil Peak Peaked at Time: Mo /Hr: 7 / 15 Outside Air: OADB: 80 WB: 64 RELHUM: 41.8% Cooling Coil Peak Heating Coil Peak Total Load Sens Load Percnt of Tot Peak Tot Sens Percnt of Tot ( Btuh) ( Btuh ) ( %) ( Btuh) ( %) ENVELOPE LOADS Solar Skylight Solar 0.00 0.00 0.00 Glass Solar 0.00 0.00 0.00 Sub Total 0.00 0.00 0.00 0.00 0.00 Conducted Skylight 0.00 0.00 0.00 Roof 1,932.93 1,932.93 - 3,223.44 Glass 0.00 0.00 0.00 Wall 0.00 0.00 0.00 Partition 5,743.68 5,743.68 - 17,949.00 SlabOnG / ExFIr 0.00 0.00 - 5,974.32 Sub Total 7,676.61 7,676.61 17.51 - 27,146.80 53.87 INTERNAL LOADS Lights 5,003.57 5,003.57 0.00 People 6,002.74 2,606.14 0.00 Misc 14,824.60 14,824.60 0.00 Sub Total 25,830.90 22,434.30 58.93 0.00 0.00 MISC LOADS Outside Air 3,574.36 2,341.81 - 12,879.90 Humidification 0.00 0.00 - 7,149.52 Infiltration 893.59 585.45 - 3,219.99 Sup. Fan Heat 2,969.98 2,969.98 0.00 Ret. Fan Heat 2,375.99 2,375.99 0.00 Duct Heat Pkup 1,096.53 1,096.53 0.00 Exhaust Heat - 585.49 - 585.49 0.00 Sub Total 10,325.00 8,784.27 23.56 - 23,249.40 46.13 OV /UNDR Sizing 0.00 0.00 0.00 Grand Total 43,832.40 38,895.10 - 50,396.20 W /Safety Factor 48,215.70 42,784.70 - 55,435.80 ' Load Express: Load Calculation Software Peak Load Summary - Alternative 1 Zone 1 Zone1 Areas ( ft2 ) Floor: SlabOnG /ExFIr: Roof: Skylight: Wall: Wall Glass: Partition: 1,332.0 186.0 1,332.0 0.0 0.0 0.0 1,860.0 Alt1 Space Sens Load Spc Sens Ld W /Sfty Fctr Cool Airflow Cool Airflw W /Sfty Fctor Cooling Check Cool Check W /Sfty Fctr Heat Airflow Heat Airflw W /Sfty Fctr 31,068.3 Btuh 34,175.2 Btuh 1,663 cfm 1,830 cfm 1.25 cfm /ft2 1.37 cfm /ft2 1,663 cfm 1,830 cfm Version 2.2 Peak Load Summary Heating Coil Peak Outside Air: OADB: 26 Cooling Coil Peak Peaked at Time: Mo /Hr: 7 / 15 Outside Air: OADB: 80 WB: 64 RELHUM: 41.8% ACTIVITY NUMBER: M08 -259 DATE: 10 -29 -08 PROJECT NAME: COMMITTEE FOR A BETTER KING COUNTY SITE ADDRESS: 3415 S 116 ST - SUITE 109 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: 0 11 17-0 ng Division Public Works Complete Comments: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 • PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP L4. Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Planning Division ❑ Permit Coordinator DUE DATE: 10-30-08 Not Applicable 'Permit Cell ler'USe'Onl y vs: +{,,; .. s .. ? , :n • :;; rLw�,Se e; ,} dr;,..,�� " '.i Lr�?'.' , ;•i ; y tij :, INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS RO T ING: Please Route Structural Review Required ❑ No further Review Required DATE: DUE DATE: 11-27-08 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Bond Company Policy Effective Expiration Cancel Impaired Bond Amount Received Insurance Name Number Date Date Date Date Amount Date FEDERATED 2 MUTUAL 9821065 08/01/2008 08/01/2009 $1,000,000.00 06/16/2008 INS 1 CBIC C11SH5647 10/08/2007 10/08/2008 $1,000,000.00 10/17/2007 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 CBIC SH5647 10/08/2007 Until Cancelled $6,000.00 10/17/2007 Name 'Role Effective Date Expiration Date YATSUK, ROMAN OWNER 10/17/2007 Untitled Page General /Specialty Contractor A business registered as a construction contractor with LI:tI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company SEATTLE MECHANICAL 4252313123 5805 -A GLENWOOD AVE EVERETT WA 98203 SNOHOMISH INDIVIDUAL UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 602771144 ACTIVE SEATTM *932PP CONSTRUCTION CONTRACTOR 10/17/2007 10/17/2009 HTG /VENT /AIR CONDITIONING UNUSED Business Owner Information Bond Information Insurance Information I or Page 1 of 1 https: / /fortress.wa. gov /lni/bbip/Detail.aspx ?License= SEATTM* 932PP 12/03/2008 ITY SIT v N.T.S. P MAP ENERGY CODE NOTES 1) HEAT IS VIA GAS, NO ELECTRIC HEAT ALLOWED -NO CHANGE TO ENVELOPE 2) PROVIDE VAPOR ON ALL WALL TO THE WARM SIDE 3) CAULK AND SEAL ALL OPENINGS TO OUTSIDE OR UNHEATED SPACES INCLUDING WEATHER -- STRIPPING AT ALL EXTERIOR DOORS. 4 MAXIMUM ALLOWABLE LOAD FOR SWITCH IS 80% OF 20 AMP CIRCUIT. ) PROVIDE DUAL LEVEL SWITCHING IN ALL ROOMS ADJACENT TO EXTERIOR WINDOWS 5) BUILDING &SITE STATISTICS TAX PARCEL NUMBER: BUILDING CODE: TENEN I AREA: CONSTRUCTION: OCCUPANCY GROUP: ZONE: AREA OF WORK: - BUILDING AREA TOTAL BUILDING AREA= 27,750 S.F. - TENANT AREA AFTER IMPROVEMENTS: SUITE 109 OFFICE= 3,838 S.F. WAREHOUSE= 4,162 S.F. TOTAL= 8,000 S.F. - OCCUPANT LOAD: SUITE 109 OFFICE= WAREHOUSE TOTAL= SCOPE OF WORK: : Lp. \RI\TE PERMIT REQUIRED FOR: [ Mechanical *Electrical plumbing liGas Piping City of Tukwila 614..C; IN DIVISION 1023049043 2006 IBC W/ WA STATE AMENDMENTS SUITE 109 8,000 S.F. V-B FULLY SPRINKLED RED B OFFICE; S -1 STOR. C /LI (COMMERCIAL / LIGHT INDUSTRIAL) 1,100 S.F. 3,838 S.F. / 100= 38 OCC. (1 EXIT- TRAVEL DISTANCE) 4,162 S.F. / 500= 8 (1 EXIT) 46 OCCUPANTS INSTALLING NEW OFFICE TENANT IMPROVMENTS W/ INTERIOR NON- BEARING PARTITIONS, AND SUSP. ACOUSTIC CEILING LEGAL DESCRIPTION 102304 43 LOT 2 OF CITY OF TUKWILA SHORT PLAT NO 90 -2 -SS RECORDING NO 9003121482 SD SHORT PLAT DAF - POR OF GOV LOT 3 & OF SE 1/4 OF NE 1/4 OF SEC 09 -23 -04 TGW POR OF GOV LOT 6 & OF SW 1/4 OF NW 1/4 OF SECTION 10 -23 -04 - BAAP 70 FT RGT OF ENGR STA H 556 +57,3 BEING A PT ON NELY MGN SHEET 1 OF 7 FOR R/W SR 99 S 118TH ST TO JUNCTION SSH NO 1 -K APPROVED JULY 23, 1957 SD PT BEING PT OF TANGENCY OF CURVE THRU POINT BEARING N 42--02 -03 E 748.51 FT TH SELY ALG SD MGN & SAID CURVE THRU C/A OF 04 -26 -56 ARC DISTANCE OF 58.12 FT TH N 41 -57 -30 E 499.81 FT TH N 15 -27 -21 E 75,56 FT TO FOB TH S 74 -32 -39 E 21289 FT TH S 78 -39 -54 E 128,28 FT TH S` 81 -20 -44 E 447,24 FT TAP OF CURVE CONCAVE TO N TH ELY ALG SD CURVE RAD OF 170 FT THRU C/A OF 15 -51 -28 ARC DIST OF 47.05 FT TH N 82 -47 -48 E 101.13 FT TO WLY MGN OF POR OF SECTION 9 CONDEMNED IN SUPERIOR COURT CAUSE NO 646697 TH S 07 -08 -23 E 544,81 FT ALONG WESTERLY MARGIN TO A LN 60 FT N OF & PLW ENGR B -LINE AS SHOWN ON SHEET 1 OF 7 FOR R/W SR 99 SOUTH 118TH ST TO JUNCTION SSH 1-K APPROVED JULY 23, 1957 TH N 88 -10 - 42 W 630.87 FT TAP 60 FT RGT OF ENGR STA B 548 +00 SAID R/W PLANS TH N 79 -41 -19 W 35921 FT TAP 70 FT RGT OF ENGR STA H 551 +64,4 SD PT ALSO BEING PT OF CUVE CONCAVE TO NORTH RAD PT BEARING N 10 -18 -41 E 748,51 FT TH NWLY ALG SD CURVE THRU C/A OF 30 -03 -04 ARC DISTANCE OF 392.59 FT TH N 41 -57 -30 E 499.81 FT TH N 15 -27 -21 E 75,56 FT TO PUB revi w approval Is sublect to error; and cm!ssiona. /.p -r,,v.,., of construction documents deco net authorize t �c violation of any adopted code or ardinanc ^. t1ecc►pt 0` approved Field Copy and conditions is acknovAcdocd: City of Tukwila BU DING DPJ S!ON REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan revipw fees. MB25? RtVItYVtU I CODE COMPLIANCE APPROVED OV 1 4 2008 f Tukwila PIVI$ION RECEIVED OCT 2 92008 PERMIT cENTEF M un in Csi Ld 0 t o G I W IA _co z LCC uo CO <as OhTJ I T J C c• Equipment Schedultyley.1) Heating Tag Make Model CFM Cooling OA CFM V /Ph SOUND RATTNJO KNIT WEIGHT EER Net BTU`S db's RTU-1 CARRIER 48HJ005 1600 11.1 46,000 72,000 82.8% 300 460/3 76 , 540 unit with economiser Seven day programmable thermostat w /night setback I BUILDING ENVELOPE, ENTIRE SPACE IS HEATED AND COOLED USED PERSCRIPTIVE ON NEW SPACES WALL TYPES 1 er X 20 GA STEEL STUD 24' Q.C. TO ROOF STRUCTURE (2V APPROX.) WITH 5I6' GYP. BD. EACH SIDE W/ R -19 INSULATION FULL HEIGHT W/ VAPOR BARRIER OF WARM SIDE. PROVIDE DEFLECTION HEAD TRACK 2. 3 519" X 25 GA. STEEL STUD 0 24' O.C. TO 6' ABOVE CEILING GRID ow AFF) WITH 519' GYP. BO. EACH SIDE WI SOUND INSULATION. DOOR SCHEDULE (MATCH EXISTING) (LEVER HANDLE ON NEW DOORS) ( RE-USE EXISTING IF POSSIBLE) E Ex. DOORS, NO CHANGES 1,3 NEW 3.O' X 9'-0" S.C. WOOD (STAINE)) WITH WOOD JAMB (STAINED), 2 PAIR BUTTS, LOCKSET, WEATHERSTRIP, CLOSER,WALL STOP, THRESHOLD. 2 NEW 3'-0' X T'-0" S.0 WOOD DOOR (STAINED) WITH WOOD JAMB ( STAINED), 2 PAIR BUTTS, LATCHSET, SOUND GASKETS, WALL STOP, THRESHOLD. ROOM SCHEDULE 1 FLOOR: NEW CARPET BASE: NEW RUBBER BASE WALL: NEW GYP. BD. PAINT CEILING: NEW SUSPENDED ACOUSTICAL CEILING AT + 9' AFF WITH R-30 INSULATION 2 FLOOR: NEW VCT BASE: NEW RUBBER BASE WALL: NEW GYP. BD. PAINT CEILING: NEW SUSPENDED ACOUSTICAL CEILING AT +9' AFF WITH R-30 INSULATION INO NEW MECH UNIT #12x2'."W000 SCREW a 24 "OC Wo LAO SCREW a 24 "0C PENETRATE BEAM BELOW 4" MIN (EXPIRES S /t2/09 LEGEND EXISTING DOOR EXISTING 4X16 0 8' OC PARTIAL FRAMING NEW HVAC UNIT WITH CURB 520 # MAX EXISTING X8 W /LUS4O 2x STIFFENERS HANGER EA HEAD OFF W /4x6 ENO EXISTING Pl1RLIN o 8' OC EXISTING OLB SECTION A N TS PROJECT: GATEWAY N SUITE 9, BUILDING 5 RTIJ CLIENT: PRECISION BUILDERS HVAC CURB DETAIL NTS Structural Enpinssr• 160 Nickerson Street Suite SO2 Seattle, 1fA %SIMU 209205.4512 (V) 008.295_09 & (F) EXISTING WALL NEW STEEL STUD WALL TO UNDERSIDE OF CEILING mil/ EX. STEEL STUD WALL, BLOW IN SOUND INSULATION CAULK AT BASE, FURR WALL INSIDE EXISTING WALL OR DOOR TO BE REMOVED. NEW DOOR #12 TEIC SCREW 0 18 "0C 0 UNIT TO CURB CURD BY MECH. CONTRACTOR 4x P.T. SLEEPER I iPPEO TO LEVEL UNIT JOB NO: 08211 DATE: 09/20/08 SHEET: S -1 FOUR —PLEX OUTLET : DUPLEX OUTLET j WALL TELEPHONE OUTLET, MUDRING, CONDUIT AND PULL STRING ONLY. NEW OPEN OFFICE NORTH NEW OFFICE HVAC PLAN SCALE: 1/8" = i' -o" SCALE: 1 /8" = 1' -O" NEW HVAC: ADD 4 TON HVAC UNIT FOR NEW SPACE EXITING: OFFICE: OCCUPANT LOAD IS 38, WITH COMMON PAT OF TRAVEL UNDER 100 LF (1014.3 EXCEPTION 1) , SINGLE EXIT PER 1015. WAREHOUSE ALSO MEETS THE ABOVE. RENTABLE OFFICE: WAREHOUSE: TOTAL SF EXPANDED OFFICE 3,838 S.F. 4,162 S.F. 8,000 S.F. v DRIVE IN DOOR •DOCK HIGH DOOR Return air diffuser Supply diffuser Exhaust far EXISTING Thermostat Damper Vertical duct SUITE 125 OOF HATCH NEW ROOF TOP UNIT SUITE 109 HVAC LEGEND • -0 f 24 1 NORTH NEW ROOF TOP UNIT ROOF PLAN SCALE: 1/32" _ 50" 112' ELEVATION VIEW SOUTH NTS MIEBEDIBMIEIDE PROVIDE NEW 4TON GAS/ELECTRIC ROOF TOP UNIT WITH NEW WITH DUCTWORK AND DIFFUSERS FOR ADDED OFFICE SPACE. NO8 2S' • KtVitNI iw rUK CODE COMPLIANCE APPROVED NOV 1 4 2008 City Of Tukwila B !WIN AjVISION RECE:Air; OCT 29 2008 PERMIT CEN f - t) w 0 to to to 0 1 CO Q f+ N 0 2 v LO u7 z 0 a. 0 z E=+ E0 cn c4 o t-I E 4,1 .,„ 0.„ coo Z CO < L 3 0 v 0 4F'