Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M08-262 - WILBUR-ELLIS
WILBUR ELLIS 16300 CHRISTENSEN RD M08 -262 Parcel No.: 2523049078 Address: Suite No: 16300 CHRISTENSEN RD TUKW Tenant: Name: WILBUR -ELLIS Address: 16300 CHRISTENSEN RD , TUKVVILA WA Owner: Name: BRCP RIVERVIEW PLAZA LLC Address: 248 HOMER AVE , PALO ALTO CA Contact Person: Name: KEO TORRE Address: 727 S KENYON ST , SEATTLE WA Contractor: Name: EVERGREEN REFRIGERATION LLC Address: 727 S KENYON ST , SEATTLE WA Contractor License No: EVERGRL954R2 DESCRIPTION OF WORK: INSTALL (2) VAV BOXES, DUCTING, GRILLES, AND DIFFUSERS. Value of Mechanical: $9,000.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC -10/06 CitAf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT EQUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 0 0 0 0 0 0 0 0 * * continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 763 -1744 Phone: 206 763 -1744 Expiration Date: 01/06/2010 M08 -262 11/24/2008 05/23/2009 Fees Collected: $271.25 International Mechanical Code Edition: 2006 Boiler Compressor: 0-3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 2 M08 -262 Printed: 11 -24 -2008 Permit Center Authorized Signature: governing this work will be complie doc: IMC -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us ,cuu whether specified herein or not. • Permit Number: M08 -262 Issue Date: 11/24/2008 Permit Expires On: 05/23/2009 Date: I (1 71 '1 1D1) I hereby certify that I have read and x• ed this permit and know the same to be true and correct. All provisions of law and ordinances The granting of this permit does not pr - e to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the peance o w rk. I am authorized to sign and obtain this mechanical permit. Signature: Date: 1 / Z ` / Cr Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M08 - 262 Printed: 11 -24 -2008 Parcel No.: 2523049078 Address: 16300 CHRISTENSEN RD TUKW Suite No: Tenant: WILBUR -ELLIS 1: ** *BUILDING DEPARTMENT CONDITIONS * ** doc: Cond - 10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS * *continued on next page ** S Permit Number: M08 -262 Status: ISSUED Applied Date: 11/03/2008 Issue Date: 11/24/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents_shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. M08 -262 Printed: 11 -24 -2008 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Print Name: • Date: 11 1 Z / (-A- M08-262 Printed: 11 -24 -2008 Site Address: Tenant Name: Property Owners Name: 13 (LC IP 04 Mailing Address: Z H z km-e r /'rvt . Name: Mailing Address: - 1 - 2 l (.;. ' 4 4 ' ,6 "'"t )3 -Mail Address: it et 6 E(gn) Y49 Company Name: Mailing Address: —7 Z 1 3 �4 �^! G✓1 Contact Person: �L �� ('w t' E -Mail Address: Contractor Registration Number: Company Name: Mailing Address: Contact Person: E -Mail Address: Company Name: Mailing Address: _.,ntact Person: E -Mail Address: CITY OF TUKWIL#"4 Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.citukwila.wa.us MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** t ,3C)O UvtSknste) ! buy- nits R (D cv-e, co.t,eo eei yip L-G C Fk/ e6hLcfSN Q: Applications'Forms- Applications On Line \3-2006 - Mechanical Permit Application.doc Revised. 4 -2006 bh Mechanical reeffilt No. A 4, 2 Project No. (For office use only) King Co Assessor's Tax No.: 2cZ 3o 4 '1 (77 L Lt� Vei no-0 City Suite Number: State Floor: New Tenant: D .... Yes ..No c1 43G1 Zip CONTACT PERSON - who do e contact when your permit is ready to be issued Day Telephone: -Lvt-- k 3 — (1 ` WilL City State Zip Fax Number: -7 -(-"C" -71 3 7'1 MECHANICAL CONTRACTOR INFORMATION ,- City City Day Telephone: Fax Number: City Day Telephone: Fax Number: 1r1c State Zip Day Telephone: Fax Number: 7,4./ t, y Z Expiration Date: ARCHITECT OF RECORD - All plan must be wet stamped by, Archite of Record State Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record State Zip Page I of 2 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood /Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator — Comm /Ind Other Mechanical Equipment Z v . f s Valuation of Project (contractor's bid price): $ , (Ai Scope of Work (please provide detailed information): i i fl- .; I / (Z ) VY'' k'-- e j, d i- c'f -L--- uve v 1 2 S ate-► . Use: Residential: New .... ❑ Replacement .... Commercial: New .... Replacement .... Fuel Type: Electric ❑ Gas ....E Other: Indicate type of mechanical work being installed and the quantity below: PERMIT APPLICATION NOTES -- Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF P RJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Print Name: Mailing Address: BUILDING OW h OR `t OR : AGENT: / Signature: / Date: / `� / • zl L) ! U 3 Date Application Accepted: 7-L 5 t hjO (. (t Q:\Applicationa\Forma- Applications On Line \3 -2006 - Mechanical Permit Application.doc Revised: 4-2006 bh Date Application Expires: City Day Telephone: Z/i(v _ - hi `'/ State Zip Staff Initials: Page 2 of 2 Parcel No.: 2523049078 Permit Number: M08 -262 Address: 16300 CHRISTENSEN RD TUKW Status: PENDING Suite No: Applied Date: 11/03/2008 Applicant: WILBUR -ELLIS Issue Date: Receipt No.: Initials: User ID: R08 -03669 JEM 1165 I�1 City of Tukwila Payee: EVERGREEN REFRIGERATION, LLC ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 003522 271.25 RECEIPT Account Code Current Pmts 000.322.102.00.0 217.00 000/345.830 54.25 Total: $271.25 Payment Amount: $271.25 Payment Date: 11/03/2008 12:36 PM Balance: $0.00 doc: Receiot -06 Printed: 11 -03 -2008 Project: 1 W , tou � S Ty of Inspection: )- INA i Address: 1 ca. 3 v 0 kte' tNs,1 Date Called: Special Instructions: Date Wanted: t Requester: Phone No! Z ! 035)- INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: -el loo pt.,f ( eE__ ' P Inspecto C 6)-}Akik--/ Date: ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd:, Suite 100. Call to schedule reinspection. Receipt No.: !Date: Proje4t: i / / i r ALL c Type of Inspection: d /`� ' j / Address: /-3 C> dACZS ,PALVN at Gf Special Instructions: Date Wanted: / "" 7 — — / a. . p.m. Requester: INSPECTION RECORD Retain a copy with permit INSPECTION N0. CITY OF TUKWILA BUILDING DIVISION R 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. EI Corrections required prior to approval. COMMIENTS: Date: P74Z-Z6Z PERMIT NO. 0 0 REINSPECTION EE REQUI ' D. Prior to inspection, fee must be at 6300 Southcente Blvd., Suy e 100. Call to schedule reinspection. pt No.: / 'Date: Heating Equipment Schedule Equip. ID Brand Name' Model No.' Capacity Btu/h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency' VAV -91- 4A PRICE FDVS Applicant Phone: 3010 CODE VAV-S1- 49 PRICE FDVS 4012 CV OF TU RECEIVE S Y IMILA NOV 2 0 NOV O a einnR � pi (9 1 0._ 210 de FERMI T CUTER ty Of TuktiBa Pdf T f 17'1TA111 rid a a%I Cooling Equipment Schedule Equip. ID Brand Name' Model No.' Capacity Btu/h Total CFM OSA CFM or Econo? SE �j� ```` or E ++`�` pp..��� Rat b`RP9_ a+ atior CUP PLIANCE Applicant Name: Evergreen Refrigeration Applicant Address: 727 9 Kenyon St. Applicant Phone: 206 - 763 -1744 CODE APPROVED NOV 2 0 � pi (9 1 0._ 210 de ty Of TuktiBa Pdf T f 17'1TA111 rid a a%I Fan Equipment Schedule Equip. ID Brand Name' Model No.' CFM Sp' HP /BHP Flow Control Location of Service Applicant Name: Evergreen Refrigeration Applicant Address: 727 9 Kenyon St. Applicant Phone: 206 - 763 -1744 pi (9 1 0._ 210 de Project Info Project Address Wilbur Ellis Date 10/29/2008 1600 Christenson Road For Building Dept. Use Tukwila, WA Applicant Name: Evergreen Refrigeration Applicant Address: 727 9 Kenyon St. Applicant Phone: 206 - 763 -1744 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Summary MECH -SUM 2006 Washington State Nonresidential Energy Code Compliance Forms Project Description Briefly describe mechanical system type and features. ❑ Includes Plans Install (2) Variable air volume boxes. FIE COPY Include documentation requiring compliant with requirements, Section 1416. r Revised July 2007 Compliance Option Q Simple System 0 Complex System O Systems Analysis (See Decision Flowchart (over) for dualifications. Use Separate fv1ECH &.complex systems.) ,„ Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. 'If available. 2 As tested accord ng to Table 14-1A through 14-1G. 3 If required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as • a • II all vaI,aUlC. /-* ICJ LCU al.l.V11511VA b I Mg nii9L 12P1 ?v r": 1 , uIn. I N.y, Li 1U kJ , as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). System Description See Section 1421 for full description of Simple System qualifications. If Heating/Cooling or Cooling Only: ❑ Constant vol? ❑ Split system? ❑ Air cooled? .i Packaged sys? ❑ <20,000 Btuh? ❑ Economizer included? If Heating Only: ❑ <5000 cfm? ❑ <70% outside air? • • • 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Summary (back) MECH -SUM Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. Simple System r Allowed (section 1420) otal Ca.. wo economize <240,000 Btuh or 10 %? Heating Only Reference Section 1421 Heating/Cooling or Cooling Only Yes Reference Section 1423 Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. Mechanical 2006 Washington State Permit Plans Checklist ME -CHK Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address Wilbur Ellis 'Date 10/29/2008 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency Ml 1411.1 Combustion htg. Indicate intermittent ignition, flue/draft damper & jacket loss 1412 HVAC controls 1412.1 Temperature zones Indicate locations on plans Ml 1412.2 Deadband control Indicate 5 degree deadband minimum Ml 1412.3 Humidity control Indicate humidistat 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types Ml 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage Ml 1412.4.2 Optimum Start Indicate optimum start controls 1412.5 Heat pump control Indicate microprocessor on thermostat schedule 1412.6 Combustion htg. Indicate modulating or staged control 1412.7 Balancing Indicate balancing features on plans Ml 1412.8 Ventilation Control Indicate demand control ventilation for high - occupancy areas 1422 Thermostat interlock Indicate thermostat interlock on plans 1423 Economizers Equipment schedule 1413 Air economizers 1413.1 Air Econo Operation Indicate 100% capability on schedule 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb 1413.2 Water Econo Doc Indicate clg load & water econoe & clg tower performance 1413.3 Integrated operation Indicate capability for partial cooling 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems 1414.1 Duct sealing Indicate sealing necessary Ml 1414.2 Duct insulation Indicate R -value of insulation on duct Ml 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Completion Requirements 1416.2.1 Commissioning Provide commissioning plan 1416.2.2 -3 Sys.Bal & Func.Test Indicate air and water system balancing & functional testing 1416.2.4 Commissioning Indicate O &M manuals, record drawings, staff training 1416.2.5 Comm. Report Indicate requirements for prelim. & final commissioning report Ml 1434 Separate air sys. Indicate separate systems on plans Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer Ml SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. 1441 Elec. water heater Indicate R -10 insulation under tank 1442 Shut -off controls Indicate automatic shut -off 1443 Pipe Insulation Indicate R -value of insulation on piping 1452 Heat Pump COP Indicate minimum COP of 4.0 1452 Heater Efficiency Indicate pool heater efficiency 1453 Pool heater controls Indicate switch and 65 degree control 1454 Pool covers Indicate vapor retardant cover 1454 Pools 90+ degrees Indicate R -12 pool cover 2006 Washington State Nonresidential Energy Code Compliance Form • • • 2006 Washington State Nonresidential Energy Code Compliance Form If "no" is circled for any question, provide explanation: 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Permit; Plans Checklist MECH -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Mechanical - General Requirements aa 4 11.1 General: Equipment shall have a minimum performance at the specified ing conditions not less than the values shown in Table 14-1A through 14-1G. If a tionally recognized certification program exists for a product covered in Tables 14-1A through 14-1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings > 225,000 Btu /h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings > 225,000 Btu/h (65 kW), including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Coo ing Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu/h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a w ilding shall be considered as a separate zone. 12.2 Deadband Controls: When used to control both comfort heating and ooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu/h) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) a mpers. These dampers shall remain closed until activated by the fire alarm stem or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings 1412.8 Ventilation Controls for High - Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu/h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246 - 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu/h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, EF CAE < 50 gal storage 0.58 0.71 50 to 70 gal storage 0.57 0.71 > 70 gal storage 0.55 0.70 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Permit; Plans Checklist MECH -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Mechanical - General Requirements aa 4 11.1 General: Equipment shall have a minimum performance at the specified ing conditions not less than the values shown in Table 14-1A through 14-1G. If a tionally recognized certification program exists for a product covered in Tables 14-1A through 14-1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings > 225,000 Btu /h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings > 225,000 Btu/h (65 kW), including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Coo ing Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu/h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a w ilding shall be considered as a separate zone. 12.2 Deadband Controls: When used to control both comfort heating and ooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu/h) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) a mpers. These dampers shall remain closed until activated by the fire alarm stem or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings 1412.8 Ventilation Controls for High - Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu/h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246 - 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu/h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, ,. 4, „Y v oal lo 1 Iv tv 1 Gcou) ..29 -QA IOX4 019p ,$mtgl14gugir pntial_Energy..Code Carop'ianm.Fnrm __.._..., _... _.__. _..._. outlets in the first story and levels below the first story of buildings duct runs are considered building envelope until they, three or more stories in height. 1. connect to the heating or cooling equipment, or 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply 2. are isolated from the exterior with an automatic shut-off damper complying air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum with Section 1412.4.1. start controls shall be designed to automatically adjust the start time of an HVAC Once outside air ducts meet the above listed requirements, any runs within system each day to bring the space to desired occupied temperature levels conditioned space shall comply with Table 14 -5 requirements. mediately before scheduled occupancy. The control algorithm shall, as a Other ducts and plenums shall be thermally insulated per Table 14 -5. nimum, be a function of the difference between space temperature and occupied Exceptions: setpoint and the amount of time prior to scheduled occupancy. 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include 1. Within the HVAC equipment. microprocessor controls that minimize supplemental heat usage during start-up, set- 2. Exhaust air ducts not subject to condensation. up, and defrost conditions. These controls shall anticipate need for heat and use 3. Exposed ductwork within a zone that serves that zone. compression heating as the first stage of heat. Controls shall indicate when 1415 Piping Systems supplemental heating is being used through visual means (e.g., LED indicators). 1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14-6. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment Exception: Piping installed within unitary HVAC equipment. with a capacity over 225,000 Btu/h shall have modulating or staged combustion Water pipes outside the conditioned space shall be insulated in accordance with control. 000 Washington State Plumbing Code (WAC 51 -26) EXCEPTIONS: 1. Boilers. 2. Radiant heaters. 1416 Completion Requirements (Refer to NREC Section 1416 and the Building 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have Commissioning Guidelines, published by the Building Commissioning Association, a means for balancing, including but not limited to, dampers, temperature and for complete text and guidelines for building completion and commissioning pressure test connections and balancing valves. requirements.) • • November 17, 2008 Keo Torre 727 S Kenyon St Seattle WA 98108 RE: CORRECTION LETTER #1 Development Permit Application Number M08 -262 Wilbur -Ellis —16300 Christensen Rd Dear Mr. Torre, This letter is to inform you of corrections that must be addressed before your mechanical permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Fire Department. At this time the Building Department has no comments. Fire Department: Alan Metzler at 206 575 -4407 if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted throuRh the mail or by a messenger service. If you have any questions, please contact me at (206) 433 -7165. Sincerely, ifer rshall it Technician enc File: M08 -262 • Guy of Tukwila Department of Community Development Jack Pace, Director P:\Pemrit Center\Correction Letters \2008 W08 -262 Correction Ltr #1.DOC jem Jim Haggerton, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Project Name: Wilbur Ellis 16300 Christensen Rd Permit File No.: M08 -262 Date: November 13, 2008 S • FIRE DEPARTMENT REVIEW COMMENTS Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575 -4407 1. Per telephone conversation with Mr. Keu Torre on November 13, 2008 the CFM ratings of the VAV boxes are incorrectly noted on both the plans and the Mechanical Summary. 2. Please submit corrected revisions. DEPARTMENTS: Building Division Public Works Complete Comments: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28-02 � PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M08 -262 DATE: 11 - - PROJECT NAME: WILBUR - ELLIS SITE ADDRESS: 16300 CHRISTENSEN RD Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11-20-08 Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Fire ILreventlon Incomplete ❑ 1110 0 DATE: DATE: Planning Division Permit Coordinator Not Applicable TUES/THURS RO TING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: Not Approved (attach comments) ❑ Permit Center Use Only • ° ,:ti::,': r .. ; ,.. =:: �... INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DUE DATE: 12-18-08 Permit Center (lie Only • CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: IPPERMIT COORD COPY • PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M08-262 DATE: 11-03-08 PROJECT NAME: WILBUR-ELLIS SITE ADDRESS: 16300 CHRISTENSEN RD X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEP RTMENTS: Pr' (' Building Division 161 Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: dedithrit V 116 Fire Prevention Structural Incomplete El - : 41 "- -- :t r ilre.` 17 .., 1 " ,-- • ; ; • C Permit CenterUse,00 • • - ' • '- --' • P... . • : i;$fiffcrPk;:$.'s INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS R UTING: Please Route Structural Review Required No further Review Required El REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2-28-02 Permit Center Use Only CORRECTION LETTER MAILED: Ott Departments issued corrections: Approved Approved with Conditions r , Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Planning Division Permit Coordinator Bldg 0 Fire' Ping 0 PW 0 Staff Initials: LI DUE DATE: 11-04-08 Not Applicable LI DUE DATE: 12-02-08 DATE: Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 11/ ( � City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Plan Check/Permit Number: M08 -262 ❑ Response to Incomplete Letter # • Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Wilbur -Ellis Project Address: 16300 Christensen Rd Contact Person: t I u✓✓-e, Phone Number: env OF n ,� NOV 1 2008 PERMIT CENTER - zol- -163 - 11 '4 Summary of Revision: /4 II ('6Uve -, S h gut %9e-e 1 me. e( 60., Pk y (, kw( tti (j n I j 01 1‹,44/ be q WI liw iedireA. , leg (I) f {K-t . c-44 1 ^- 4 f a LI-e 01c wel . Sheet Number(s): 114 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on 1 i I vim \applications\forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Name Role Effective Date Expiration Date EVERGREEN REFRIGERATION LLC PARTNER /MEMBER 12/22/2005 Bond Amount PATTON, DAVID PARTNER /MEMBER 01/06/2006 104667361 PATTON, RODGER PARTNER /MEMBER 01 /06/2006 PATTON, MATTHEW PARTNER /MEMBER 01 /06/2006 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 TRAVELERS CAS a 104667361 01/01/2006 Until Cancelled $12,000.00 01/03/2006 Untitled Page • Business Owner Information • Page 1 of 2 General /Specialty Contractor A business registered as a construction contractor with LEtI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type LIMITED LIABILITY COMPANY Parent Company EVERGREEN REFRIGERATION LLC 2067631744 727 S KENYON ST SEATTLE WA 98108 KING UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 602512953 ACTIVE EVERGRL954R2 CONSTRUCTION CONTRACTOR 1/6/2006 1/6/2010 EVERGI*201 D7 GENERAL UNUSED Bond Information https: // fortress .wa.gov /lni/bbip/Detail. aspx ?License= EVERGRL954R2 11/24/2008 20' -0" LUGGAGE D "ROP: OFF 103_] PHONE ROOM PRIVATE OFFICE 1 109 I QV A13 I � AIL N ��.\ 10" N N U'. J «U WORK STATION 8 X 8 WORK X T A A TION 20'— /1 EXISTING VAV LARGE CONF. RM PRIVATE OFFICE PRIVATE OFFICE RECEPTION AREA [1011 EXISTING VAV E 20'-- ff 106 TRAI ING MAIL /COPY ROOM 113 CATERING 1 WORK STATION WORK STATION 8X8 REMOVE ANY RETURN GRILLL IN THIS ROOM LINE VOLTAGE COOLING T -STAT PROVIDE BY ERL INSTALLED BY OTHERS 8 X 8 115 1 20' -0" PHASE 2 STORAGE 107_ PRIVATE CF IC - 126'! WORK STATION 8 X 8 WORK STATION 8 X 8 N WORK STATION 8X8 SCALE : 1/8" = 1' -0" 400 CFM WORK STATION 8 X 8 128 WORK STATION 8 k 8 119 I 120I I WORK STATION 8X8 WORK STATION 8 X 8 PRIVATE OFFICE 20 -0" WORK STATION 8 X 8 1211 WORK STATION 8X8 122 I SCALE : 1/8" = 1' -0" HVAC FIRST FLOOR PLAN 20' -0" Il U PRIVATE OFFICE 1 212 1 In BREAK ROOM 253 213 20'- PRIVA E--- OFFICE WORK STATION 8 X 8 131 WORK STATION 8X8 130 133 I COFFEE 123 123 I 134 SCS. MICR. OFFIC.E (E) 1 124 I PRIVATE OFFICE 214 I 252 WORK STATION 6 X 8 2511 WORK STATION 6 X 8 R &D NETWORK LAB HVAC SECOND FLOOR PLAN WORK STATION 8 X 8 137 WORK STATION 8 X 8 136 I WORK STATION 8X8 129 WORK STATION 8X8 125 ] WORK STATION WORK STATION 8X8 8X8 132j 135 UI PRIVATE OFFICE 215 20'- PHASE 21 PRIVATE OFFICE 216 CLOSET 175 I WORK STATION 6 X 8 249 I WORK STATION 6 X 8 248 I PRIVATE OFFICE 138 APPL. NOR. OFFIC. (E) PROG. MNG OFFICE (E) 20' \R WORK STATION 7x9 46 Jf WORK STA TON 6 X 8 234 WORK STATION 8 X 8 235 WORK STATIO 8 APPL. MNGR. OFFICE (E) 139 Fl WORK STATION 8 X 8 1 220 WORK STATION 8 X 8 219 WORK STATION 8 X 8 1 21,8 I WORK STATION • 7x9 244 I WORK STATION 7x9 245 WORK STATION 8 X 8 172 WORK STATION 8 X 8 171 WORK STATION 8X8 1 169 ] E WORK S ION 8 X 8 233 WORK STATION 8 X 8 236 WORK STATION n 8 X 8 167 20'- DEV. MNGR OFFICE (E) I 140 I 1 223 I WORK STATION WORK STATION 8 X 8 8 X 8 _ 226 WORK STATION WORK STATION 8 X 8 8 X 8 WORK STATION 8 X 8 237 1 222 I I 221 WORK STATION 7x9 [ 242] WORK STATION 7x9 1 243 I WORK STATION 8X8 166 ] WORK STATION 8 X 8 1 238 IT OFFICE (E) 141 I- 225 WORK STATION WORK STATION 8 X 8 8 X 8 1 224 ] 143 142 165 CLOSET 239 WORK STATION 7x9 • WORK STATION 7x9 WORK STATION 8X8 I 240 I 241 WORK STATION 6X8 WORK STATION 8 X8 20'- 1/ BREAK ROOM 170 WORK STATION WORK STATION 8X8 8X8 WORK STATION WORK STATION 8X8 8X8 228 WORK STATION WORK STATION 8X8 8X8 227 I WORK STATION 6X8 146 WORK STATION 8 X 8 I 145 I CNC OFFICE (E) 144 229 WORK STATION 8 X 8 164 I ti WORK STATION 8X8 1 149 I [ 232 I 2311 1 230 I FILE ROOM 148 I WORK STATION 8 X 8 1 163 I 20' -0" WORK STATIO 8X8 162 PHASE 1 PRIVA"vE OFFICE 0 150 EXISTING \'AV - cc SERVER ROOM 160 ORK STATION 8X8 [T51 20' -0" LARGE CONE, RM 161 L J WORK STATION 8 X 8 0 1 153 E N ©V 2 ()Z�U�7 ODE COMPLIANCE City BA U NG kwila SION WORK STATION 8X8 WORK STATION 8x8 EXISTING VAV WORK STATION 8X8 ddb 1 155 MOVE 156 E 20' -0" 158 157 WORK STATION 8X8 RECEIVED CITY OF TUKWILA NOV 1 . g 2008 PERMIT CENTER [ 159 I E WORK STATION 8X8 XISTING VAV E WORK STAT ON 8x8 0 en 0 I 0 to NOTE: ALL NEW DIFFUSERS ARE TO BE TITUS MCD OR EQUIVALENT MOB 2 w w w w w w co 0) I NOT PUBLISHED. ALL .RIGHTS RESERVED. THE DRAWING AND SPECIFICATIONS. IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF EVE- RGREEN REFRIGERATION INC. NO PART THEREOF SNAIL DE REPRODUCED, COPIED, ADAPTED. DISC- LOSED OR DISTRIBUTED TO OTHERS, SOLD. PUB- LISHED OR OTHERWISE USED WITHOUT THE PRIOR WRITTEN CONSENT OF AND APPROPRIATE COMPEN- SATION TO EVERGREEN REFRIGERATION INC. VISUAL CONTACT WITH THE ABOVE DRAWINGS OR SPECIFIC- ATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. CO CD Q Cu Cu W W ® a ® a N w 5 w w CO (/7 CD z 0 b Z z 0 IR- a U I— -5 Oo z O Q REVISIONS NO DATE ITEM SHEET: 11/04/08 DRAWING DATE: DWG. BY: GN CHK. BY: • JS JOB NO.: 58080 DWG. FILE: CO #1 10/16/08 58080M1 -- 0 M2 2 O F 2 SHEETS SYMBOL SYMBOL ABBV. LEGEND DESCRIPTION a RD DUCT SECTION SUPPLY ri DUCT SECTION - RETURN /EXHAUST RECTANGULAR DUCT ROUND DUCT FLEXIBLE DUCT L MVD MANUAL VOLUME DAMPER lip BDD BDD BACKDRAFT DAMPER 8 1 MD MOTORIZED DAMPER 1- REVISIONS FD FIRE DAMPER ITEM ! 11 FSD FIRE /SMOKE DAMPER (I20V POWER REQ•) 11/19/08 GEN. REV., CEILING RADIATION DAMPER SD SD SMOKE DETECTOR T flLVL rtLsWL. THERMOSTAT CITY OF TUKWILA SENSOR FIDV 19 zoo REFRIGERANT LINES IFT CENTER Q S R R -° R G NATURAL GAS LINES G G OBI CEILING DIFFUSER (SUPPLY) CEILING DIFFUSER (RETURN /EXHAUST) DRAWING DATE: EXHAUST FAN (CEILING MOUNTED) .Li 1 Q I GN INLINE FAN CHK. BY: ©g JS PROPELLER FAN I 58080 SIDEWALL DIFFUSER DWG. FILE: LEI 58080M1 - DUCT FITTING CORRECTION I SHEET: )3.O. J. 12'� I OF DATUM LT R# UNIT TAG f a z DUCT RISER T 1 4 o o Lu p C N Q 0 D- r RD RVI W ,,- -... 2 CO .1 8 co co 1- REVISIONS NO DATE ITEM ! 11 11/04/08 CO #1. 11/19/08 GEN. REV., X DRAWING DATE: 10/16/08 .Li DWG. BY: GN CHK. BY: JS JOB NO.: 58080 DWG. FILE: 58080M1 - I SHEET: I OF 2 NpFT 405 Ir VM Nak SCALE : NONE Paz it fortr0 VICINITY MAP Black >,Tr4i m a swa q V1S1 VUYM h.k -.L. 11 N'. fq' f i biy 11i 1: 2 I1 IY 21i{ al 7i i MARK VAV -S1-4A VAV -S1 -4B MANF. PRICE PRICE MODEL SCHEDULE OF VAV BOXES FAN HP 1/4 1/4 INLET INS 10 10 MAX MIN ELECTRIC HEATER CFM CFM VOLTS 600 0 480 1600 0 480 PHASE MOP 15 15 WEIGHT LBS 88 88 MODEL SP -A250 MARK HTF 1 MANF. GREENHECK A HEAT TRANSFER FAN SCHEDULE CFM 250 S.P. 0 COMPLETION AND COMMISSIONING FOR MECHANICAL SYSTEMS RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER WA ENERGY CODE (WSEC) SECTION 1416.1. AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER PER WSEC SECTION 1416.2.4.1 ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCE REPORT SHALL BE PROVIDED TO THE OWNER PER WSEC SECTION 14516.2.2.1. FOR WAREHOUSES SEMIHEATED SPACES AND SIMPLE SYSTEMS AS DEFINED IN n C 0 1 2 :'� �� -• ■. C , ADJUSTED, SEQUENCES OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORD WITH SPECIFICATIONS AND APPROVED PLANS, AND A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE FILED WITH THE OWNER PER WSEC SECTION 1416.2.3.2. FOR ALL OTHER SYSTEMS: HVAC CONTROL SYSTEMS SHALL BE TESTED, CALIBRATED AND ADJUSTED, SEQUENCES OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORD WITH SPECIFICATIONS AND APPROVED PLANS PER WSEC SECTION 1416.2.3.2; NECESSARY TESTS SHALL BE IDENTIFIED PER WSEC SECTION 1416.2.3; A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE REPARED PRIOR TO IS UANCE OF A FINAL CER TIFICATE O OCCUP NC ER W EC „Quo_ 1416.2.5.1 AND A COMPLETE FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE FILED WITH THE OWNER PER WSEC SECTION 1416.2.5.2. VOLTS 115 PHASE 1 F E L Permit No. Dat (1 - 1,-( Hp /A 0.8 A 01` o at :7 iv Isvila 7 1).X Onlia0N NOTES LOCATED ON CEILING 2 Pier rovlkw approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any,:dopted code or ordinanco. Receipt of approved Field C py and c Miens is ac °u o y ledoed: I By of 10 ' C APPRO N � 1 Z, % !!F I u i \a � SO , 13 r SEPARATE PERMIT REQUIRED FOR: 0 Mechanical �l�tectrical ILambing Gas Piping City of Tukwila � BIUILDIING D I IO des sh�lll hbe m ado of work without prior a to v I of Tukwila Building i of NOTE: Revisions will require � Division. _�. `ate may include u new pion submittal --- �- •---.� _ a �.� d rail pla,ivv feel DUCTWORK 1.1 GENERAL NOTES ALL DUCT DIMENSIONS ON PLAN ARE CLEAR INSIDE DIMENSIONS, ADD 2" TO EACH DIMENSION TO OBTAIN OUTSIDE DIMENSION. ADD 4 "TO EACH DIMENSION IF DUCTWORK IS ON THE EXTERIOR OF BUILDING. 1.2 THE FIRST NUMBER ON ALL DUCT DIMENSIONS IS THE WIDTH AND THE SECOND NUMBER IS THE HEIGHT. 1,3 MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT RATING LESS THAN 50, PER IMC 602.2.1. 1.4 SEAL ALL TRANSVERSE JOINTS FOR DUCTWORK WITH STATIC PRESSURE BETWEEN 1/2 INCHES AND 2 INCHES. DUCTWORK WHICH IS DESIGNED TO OPERATE AT PRESSURES ABOVE 1/2 INCH WATER COLUMN STATIC PRESSURE SHALL BE SEALED IN ACCORDANCE WITH STANDARD RS -7. 1.5 ALL DUCT GAUGES PER SMACNA, IMC 603-4. 1.6 ALL DUCT SUPPORTS PER SMACNA, IMC 603 -10. 1.7 ATTACH DIFFUSERS AND GRILLES TO T -BAR GRID PER WA STATE & LOCAL CODES. 1.8 BALANCING DAMPERS ARE TO BE INSTALLED ON ALL BRANCH DUCTS OR DIFFUSERS. INSULATION 2.1 INSULATE OR LINE DUCTWORK PER WA. STATE ENERGY AND MECHANICAL CODES. 2.2 INSULATE REFRIGERANT & CONDENSATE PIPING PER STATE & LOCAL ENERGY CODES. GENERAL CONTRACTOR 3.1 GENERAL CONTRACTOR TO PROVIDE AND CUT OPENINGS FOR ALL ROOFTOP, CEILING, FLOOR, AND WALL PENETRATIONS, INCLUDING WEATHERPROOF SEALING AND FIRE PROOF LINING PER IMC & IBC. 3.2 GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATION AND DIMENSIONS WITH ERL BEFORE FRAMING OPENINGS. 3.3 GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING, AND PAINTING AS REQUIRED FOR MECHANICAL WORK. 3.4 GENERAL CONTRACTOR TO PROVIDE ADEQUATE STRUCTURAL SUPPORT AS REQUIRED FOR MECHANICAL WORK. 3.5 GENERAL CONTRACTOR TO PROVIDE ADEQUATE ENGINEERING AS REQUIRED FOR MECHANICAL WORK. 3.6 GENERAL CONTRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL MECHANICAL EQUIPMENT. 3.7 GENERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY ERL PROVIDE ALL CANT STRIPS AND CURB INSULATION, AND SEAL AGAINST LEAKS. 3.8 GENERAL CONTRACTOR TO PROVIDE ALL CUTTING AND PATCHING OF T -BAR CEILING AS REQUIRED FOR HVAC INSTALLATION. 3.9 GENERAL CONTRACTOR TO PROTECT ALL OPENINGS THROUGH FLOORS PROVIDED FOR DUCTWORK INSTALLATION IN ACCORDANCE WITH TABLE 601 OF INTERNATIONAL BUILDING CODE, WHERE REQUIRED BY SECTION 707 OF IBC. ELECTRICAL 4.1 ERL TO INSTALL ALL LOW VOLTAGE CONTROL WIRING, CONDUIT WILL BE PROVIDED BY ELECTRICAL CONTRACTOR. 4.2 ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL CONNECTIONS, DISCONNECTS, AND STARTERS FOR MECHANICAL EQUIPMENT. 4.3 ELECTRICAL CONTRACTOR TO VERIFY EQUIPMENT SIZES, LOADS AND LOCATIONS WITH ERL MECHANICAL PLAN AND WITH FIELD CONDITIONS. 4.4 ELECTRICAL CONTRACTOR TO INTERLOCK BATHROOM EXHAUST FANS WITH LIGHT SWITCH. 4.5 ERL TO PROVIDE 7 -DAY NIGHT SETBACK, PROGRAMMABLE TYPE T -STAT WITH CAPABILITY OF 5 °F DEADBAND. 4.6 ERL TO VERIFY FINAL LOCATION OF THERMOSTAT WITH CUSTOMER. 4.7 ELECTRICAL CONTRACTOR TO PROVIDE ELECTRICAL GCFI OUTLET WITHIN 25 FT OF EACH PIECE OF MECHANICAL EQUIPMENT. PLUMBING 5.1 PLUMBING CONTRACTOR TO FURNISH AND INSTALL ALL GAS PIPING FOR MECHANICAL EQUIPMENT PER CODE. 5.2 PLUMBING CONTRACTOR OFFSET VENTS 10 FEET MINIMUM FROM ALL HVAC FRESH AIR INTAKES OR 2' ABOVE HIGHEST POINT OF INTAKE, IMC 401.5.1. 5.3 CONDENSATE DRAINS FROM RTU BY ERI TO DRAIN WITHIN 12" OF UNIT. CONDENSATE DRAINS FOR AIR HANDLERS BY PLUMBER. ENERGY CODE COMPLIANCE 6.1 AT A MINIMUM, EACH FLOOR IS TO BE CONSIDERED A SEPARATE ZONE. VERIFY THERMOSTATIC CONTROL FOR EACH ZONE AS INDICATED ON PLANS. 6.2 OUTSIDE AIR INTAKES, EXHAUST OUTLETS, AND RELIEF OUTLETS SERVING CONDITIONED SPACES SHALL BE EQUIPPED WITH DAMPERS WHICH CLOSE AUTOMATICALLY WHEN THE SYSTEM IS OFF OR UPON POWER FAILURE, PER WSEC SEC. 1412.4.1. 6.3 AIR ECONOMIZERS WHERE REQUIRED BY CODE ARE INDICATED BY THE EQUIPMENT SCHEDULE AT 100% CAPABILITY, CONTROL AND OPERATION OF THE ECONOMIZER SHALL COMPLY WITH WSEC SEC. 1423. MECHANICAL CODE COMPLIANCE 7.1 WHERE REQUIRED PROVIDE AUTOMATIC SHUTOFF ACTIVATED BY SMOKE DETECTORS IN EACH SYSTEM DELIVERING HEATING OR COOLING AIR IN EXCESS OF 2000 CFM. DETECTORS SHALL BE LOCATED IN THE MAIN RETURN AIR PER IMC 606. U co N N. LL. NOT PUBLISHED. ALL RIGHTS RESERVED. THE DRAWING AND SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTI OF EVE- RGREEN REFRIGERATION INC. NO PART THEREOF SHALL BE REPRODUCED. COPIED, ADAPTED, DISC- LOSED OR DISTRIBUTED TO OTHERS, SOLD, PUB- LLSHED OR OTHERWISE USED WITHOUT THE PRIOR WRITTEN CONSENT OF AND APPROPRIATE COMPEN- SATION TO EVERGREEN REFRIGERATION INC. VISUAL CONTACT WITH THE ABOVE DRAWINGS PR SPECIFIC- ATIONS SHALL CONSTITUTE CONCLUSIVE, EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. 00 sID 0 0 Iii D D z Q U I- V] 0 Ct U 0 LI, F- U? 0 `' z I � ~ J Z EL U} D W > p 0 ix 0 a. eL Q III W D lI W D Q CONSTRUCTION DRAVVINGS AS BUILT DRAWINGS