Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M08-268 - GAMEFLY
GAMEFLY 12783 GATEWAY DR M08 -268 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: doc: IMC -10/06 2716000060 12783 GATEWAY DR TUKW MIKE NELSEN 899 WEST MAIN , AUBURN WA Value of Mechanical: $4,000.00 Type of Fire Protection: Citylif Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us GAMEFLY 12783 GATEWAY DR , TUKWILA WA RREEF AMERICA REIT II CORP/ PO BOX 4900 #207 , SCOTTSDALE AZ SEATTLE MECHANICAL 5805 -A GLENWOOD AV , EVEREIT WA Contractor License No: SEATTM *932PP DESCRIPTION OF WORK: PROVIDE NEW 1 TON DUCTLESS SPLIT SUSTEM A/C ONLY FOR NEW SERVER ROOM Furnace: <100K BTU 0 >100K BTU 0 Floor Furnace 0 Suspended/Wall/Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat /Refrig /Cooling System.... 0 Air Handling Unit <10,000 CFM 1 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 0 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial/Industrial 0 MECHANICAL PERMIT EQUIPMENT TYPE AND QUANTITY * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 253- 939 -9495 Phone: 425 231 -3123 Expiration Date: 10/17/2009 M08 -268 12/03/2008 06/01/2009 Fees Collected: $215.38 International Mechanical Code Edition: 2006 Boiler Compressor: 0-3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15-30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment M08 - 268 Printed: 12 -03 -2008 Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied The granting of this permit does not pres construction h- • - ormance • Signature: Print Name: doc: IMC -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us th, Permit Number: M08 -268 Issue Date: 12/03/2008 Permit Expires On: 06/01/2009 Date: tit 0,1 ed this permit and know the same to be true and correct. All provisions of law and ordinances hether specified herein or not. e to give authority to violate or cancel the provisions of any other state or local laws regulating authorized to sign and obtain this mechanical permit. Date: /'/V This permit shall become and void ' ' work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M08 -268 Printed: 12 -03 -2008 Parcel No.: 2716000060 Address: 12783 GATEWAY DR TUKW Suite No: Tenant: GAMEFLY 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: M08 -268 Status: ISSUED Applied Date: 11/06/2008 Issue Date: 12/03/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. * *continued on next page ** doc: Cond -10/06 M08 -268 Printed: 12 -03 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. doc: Cond -10/06 M08 -268 Date: el e ordinances governing or local laws regulating Printed: 12 -03 -2008 • CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 littp.-/Avww.ci.tukwila.wa.us rE y L y O � CATi� Site Address: 12783 gateway drive. Tenant Name: GAMEFLY Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Property Owners Name: RREEF PROPERTY MGMT. Mailing Address: 12720 GATEWAY DRIVE, SUITE 200 TUKWILA WA. 98168 Zip ,, � ' x" > Ft d t .7 TITERS ON who do we contact when your,permit.1s readyto be Issued Name: Mike Nelsen Mailing Address: 899 west main Auburn wa. E -Mail Address: seattlemechanical @msn. corn NTRACTORINFORMATI �:: >,� ..ra >;�•< n - :x.:•*.'t�r a .> a . ,-,�, y ws"s' rP.: �sxcr ca {3;��Lw. Qd � A (C ontractorinformadon foc (pg 4),for Plumbing sud.Gas Piping Company Name: Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: :ARCHITECT OFx`-RECO g�i:i .�•'.•Y. ;•rJ�"�"�'S7r l.`:k '� i'rriiek: 9 ' , �i D —All plans, must be wet stamped by chl of Reco�rd g: 9 1) - 3'a c r = .:: ' . — , : <.r 1 ,i.:t . 1!'a 44t H Company Name: On up 1, Mailing Address: j °f I L A j it (M' Or. Contact Person: 'O r& 1 E -Mail Address: P;+ w-sY cFv'k4.$ aav YEA �'GZ•`f3t -�' NL�., �i c'T' '`"'tJt.Y es?t� •-k :i^'^s vii + "1 ENGINEER�OFaREC . All plans must`.bewet stamped-by Engineer ofsRecord,•*' N o'-. t gg s rat y (r r t 7. "rN- 0W ?n5". 4 . L1•° §:"T a'?',^.. Wa+��!'; �' ;r Ce tiC".l z'cC `• ,.., t.'S^ ^ s"tl+ ..:t.'',.. - 'S .:'n'': a.". "+BF,''.,v Company Name: Mailing Address: Contact Person: E -Mail Address: Q:Wpplications\Forms- Applications On Lin&3 -2006 - Permit Application.doc Revised: 9 -2006 bh King Co Assessor's Tax No.: 2716000060- 0060 -08 Suite Number: Floor: New Tenant: © Yes ❑..No City Day Telephone: 253 939 - 9495 City State Fax Number: 253- 939 -9260 ..5ek l4— City Day Telephone: State State Zip Zip City Day Telephone: Fax Number: Expiration Date: state tp ' Fax Number: Zip State City Day Telephone: Fax Number: Page 1 of6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: _ Qty Fumace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM 1 Incinerator — Comm/Ind MECHANICAL PE_RN 206 = 43 13670- rt,'S:!'W ricak. rtJT.. ` ° k4 i.-'�t.`�.Si�rZS.y!3v�'�. ": . aaroo'�'%:, �:' ^Ail... .57,7; tr- MECHANICAL CONTRACTOR INFORMATION Company Name: IECS INC Mailing Address: 899 WEST MAIN AUBURN WA. 98001 Zip Contact Person: TERRY COURSE E -Mail Address: SEATTLE MEHCANICAL Fax Number: 253 939 - 9260 Contractor Registration Number: IECS * * * 04 4QL Expiration Date: 11/13/ 08 Valuation of Mechanical work (contractor's bid price): $ 4, 000 Provide new 1 ton ductless Split system A/C only Scope of Work (please provide detailed information): for new server room. Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... © Replacement .... ❑ Fuel Tvpe: Electric ❑ Gas....❑ Other: Indicate type of mechanical work being installed and the quantity below: Q: ApplicationsWorms- Applications On Line'3 -2006 - Permit Application.doc Revised: 9 -2006 bh City State Day Telephone: 253 939 - 9495 Page 4 of 6 PERT IIT APPL ICA` N NOTES AppLcale allpermi s t n pphcation Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER .. , / ,k11.J 'HORIZED AGENT: Signature: Print Name: V ( PO Mailing Address: C J Gi 4-r F Gi / t'\ Q:WpplicationsWonns- Applications On Line43 -2006 - Permit Application.doc Revised: 9- 2006 bh Day Telephone: City Date: / 1114)1} � � l i f y is civcoi State Zip Date Application Accepted: 1 9 , I Date Application Expires: Staff Initials: w 1 Page 6 of 6 Parcel No.: 2716000060 Address: 12783 GATEWAY DR TUKW Suite No: Applicant: GAMEFLY Receipt No.: R08 -03857 Payee: IECS, INC. ACCOUNT ITEM LIST: Description MECHANICAL - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Initials: JEM Payment Date: 12/03/2008 09:50 AM User ID: 1165 Balance: $0.00 TRANSACTION LIST: Type Method Descriptio Amount Payment Check 43041 172.30 Account Code Current Pmts 000.322.102.00.0 172.30 Total: $172.30 Permit Number: M08 -268 Status: APPROVED Applied Date: 11/06/2008 Issue Date: Payment Amount: $172.30 0131 12/03 9707 TOTAL 172.30 doc: Receiot -06 Printed: 12 -03 -2008 Payee: IECS ACCOUNT ITEM LIST: Description don! HAnAint -(1R PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 2716000060 Permit Number: M08 -268 Address: 12783 GATEWAY DR TUKW Status: PENDING Suite No: Applied Date: 11/06/2008 Applicant: GAMEFLY Issue Date: Receipt No.: R08 -03695 Payment Amount: $43.08 Initials: WER Payment Date: 11/06/2008 09:53 AM User ID: 1655 Balance: $172.30 TRANSACTION LIST: Type Method Descriptio Amount Payment Check 42866 43.08 RECEIPT Account Code Current Pmts 000/345.830 43.08 Total: $43.08 Printp.d 11- (1R -2nnA t Projec: G- � 1�r Typ f Inspection: /oar- - /ern 1 . Address; �� / gyp y Date Called: Special Instructions: //2 A a- rv/ / fi. s .— .07403'7 - o I D/2 anti v4 25 i Q a. q� Requester: P hone No 20 6- - 2 5 s - aoW $_ INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 pprov , per applicable codes. Corrections required prior to approval. COMMENTS: a 11 II) i'0 Inspector: I Date:/ 2 a„ i erg o d ❑ $60.00 REINSPE ► ION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Project: D ��� Type o section: �� / 4 th• — Address: 2 F3X9 Date Cal S ecial Instructions: 4 Date Wanted: ._ e' v r a.m� p.m. Requester: Phone No: INSPECTION NO. INSPECTION RECORD Retain a copy with permit /4, 24V PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 8- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ( -3670 pproved per applicable codes. El Corrections required prior to approval. COMMENTS: Date' d r El $58.00 REINSPECTIO(FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: (Date: A MITSUBISHI ELECTRIC HVAC Advanced Products Division SUBMITTAL DATA:, MS -Ai 2WA:& mutIm-iwg try r ,,,12 000„ 8iu/ h,131 1L1,:PiMOUtiTEQAIR- C0NDIT10NING SYSTEM Notes: Job Name: GAME FLY Purchaser: IECS. INC Submitted to: IECS INC Ci Of Tukwila Unit Designation: SERVER ROOM AC GENERAL FEATURES • Limited warranty: one year on parts and defects and six years on compressor • Compact side discharge outdoor unit • Zone control • Wireless remote controller • Automatic fan speed control • Quiet operation — both indoor and outdoor units • Auto restart following a power outage • Self check function — onboard diagnostics • Advanced microprocessor control Rated capacity 12,000 Btu /h SEER 13.0 Total input 690 Power supply 115V, 1 phase, 60 Hz Voltage Indoor - Outdoor L1 -N 115V, 1 Phase, 60 Hz Indoor - Outdoor 2 -N 115V, 1 Phase, 60 Hz Indoor - Remote Controller wireless Indoor unit MCA 1 2 A Fan motor 0.95 F.L.A. Airflow (Low- Medium -High) 222 - 286 -406 Dry CFM 198 - 254 -363 Wet CFM Sound level (Lo- M1- M2 -Hi) 33 -38 -45 dB(A) DIMENSIONS INCHES MM W 30`- -11/16 780 D 8 -1/4 210 H 11 -3/4 299 Weight (lbs/Kg) 23 / 10 Field drain pipe size I.D. (inches /mm) 1/2 / 12.7 octVit OMPLIAIVCE CODE C APPROVED NOV 18 2008 RILE C Loc TUKWILA WA.' Engineer: ¥1 05 2,4)6 For ❑ Reference ❑ Approval ['Construction Schedule No.: AC -1 , FCU -1 Remote Controller Indoor Unit: MS -Al2WA mksUgrm. Split - ductless A/C and Heat Pumps Date 10/21/2008 Outdoor Unit: MU Al2WA Outdoor Unit Compressor Rotary R.L.A. 10.82 L. R A. 56 MCA 16 Breaker size 20 A Fan motor F L.A. Sound level 52 dB(A) DIMENSIONS INCHES MM W 31 -1/2 800 D 11 -1/4 286 H 21 -5/8 550 Weight (lbs /Kg) 96 / 44 Refrigerant type R410A Refrigerant pipe size O.D. (inches /mm) liquid side 1/4 / 6.35 gas side 1/2 / 12.7 Max. refrigerant pipe length (ft/m) 65 / 20 Max. refrigerant pipe height difference (ft/m) 35 / 11 Connection method flared NOTES: Test conditions based on ARI 210 Rating conditions (cooling) indoor: D.B. 80 °F. W.B. 67 °F outdoor: D.B. 95 °F, W.B. 75 °F. Operating range Low ambient operation o 10 °FDB is possible by installing a Low Ambient Head Controller, Part No. ICM326HM1 RECE WED Nov 06 2008 PEHMIT CENTEF Indoor intake air temp. Outdoor intake air temp. Cooling Maximum 95 °FDB, 71 °FWB 115 °FDB Minimum 67 °FDB, 57 °FWB 67 °FWB A MITSUBISHI ELECTRIC HVAC Advanced Products Division SUBMITTAL DATA:, MS -Ai 2WA:& mutIm-iwg try r ,,,12 000„ 8iu/ h,131 1L1,:PiMOUtiTEQAIR- C0NDIT10NING SYSTEM Notes: Job Name: GAME FLY Purchaser: IECS. INC Submitted to: IECS INC Ci Of Tukwila Unit Designation: SERVER ROOM AC GENERAL FEATURES • Limited warranty: one year on parts and defects and six years on compressor • Compact side discharge outdoor unit • Zone control • Wireless remote controller • Automatic fan speed control • Quiet operation — both indoor and outdoor units • Auto restart following a power outage • Self check function — onboard diagnostics • Advanced microprocessor control Rated capacity 12,000 Btu /h SEER 13.0 Total input 690 Power supply 115V, 1 phase, 60 Hz Voltage Indoor - Outdoor L1 -N 115V, 1 Phase, 60 Hz Indoor - Outdoor 2 -N 115V, 1 Phase, 60 Hz Indoor - Remote Controller wireless Indoor unit MCA 1 2 A Fan motor 0.95 F.L.A. Airflow (Low- Medium -High) 222 - 286 -406 Dry CFM 198 - 254 -363 Wet CFM Sound level (Lo- M1- M2 -Hi) 33 -38 -45 dB(A) DIMENSIONS INCHES MM W 30`- -11/16 780 D 8 -1/4 210 H 11 -3/4 299 Weight (lbs/Kg) 23 / 10 Field drain pipe size I.D. (inches /mm) 1/2 / 12.7 octVit OMPLIAIVCE CODE C APPROVED NOV 18 2008 RILE C Loc TUKWILA WA.' Engineer: ¥1 05 2,4)6 For ❑ Reference ❑ Approval ['Construction Schedule No.: AC -1 , FCU -1 Remote Controller Indoor Unit: MS -Al2WA mksUgrm. Split - ductless A/C and Heat Pumps Date 10/21/2008 Outdoor Unit: MU Al2WA Outdoor Unit Compressor Rotary R.L.A. 10.82 L. R A. 56 MCA 16 Breaker size 20 A Fan motor F L.A. Sound level 52 dB(A) DIMENSIONS INCHES MM W 31 -1/2 800 D 11 -1/4 286 H 21 -5/8 550 Weight (lbs /Kg) 96 / 44 Refrigerant type R410A Refrigerant pipe size O.D. (inches /mm) liquid side 1/4 / 6.35 gas side 1/2 / 12.7 Max. refrigerant pipe length (ft/m) 65 / 20 Max. refrigerant pipe height difference (ft/m) 35 / 11 Connection method flared NOTES: Test conditions based on ARI 210 Rating conditions (cooling) indoor: D.B. 80 °F. W.B. 67 °F outdoor: D.B. 95 °F, W.B. 75 °F. Operating range Low ambient operation o 10 °FDB is possible by installing a Low Ambient Head Controller, Part No. ICM326HM1 RECE WED Nov 06 2008 PEHMIT CENTEF DIMENSIONS: MS -Ai 2WA & MU -AI 2WA MS -Al2WA PERFORM CER /VFIEO 30 -11/16 C SD - MS -Al2WA / MU -Al2WA - A - 200606 -A ® MITSUBISHI ELECTRIC / HVAC 2006 MU -Al2WA u) N Air in handle N 7/8 IIIII I IIIIIIIIIIIIIIIIIIII IIIIIIIIIIII 11111 11111111111 111111111 IIIIIIIIIIII 111111111111111111111111111 111111111111 1111111111111111 1111111111111111111111 IIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIII 5-15/18 15 -3/4 b Air out 1-29/32 19 -11/16 Drainage hole ( 1 -5/8 1 -9/16 31 -1/2 29/32 11-1/4 17/32 Liquid pipe Gas pipe 2 -23/32 MITSUBISHI ELECTRIC HVAC Advanced Products Division Mitsubishi Electric & Electronics USA, Inc. 3400 Lawrenceville Suwanee Rd Suwanee, GA 30024 Tele: 678- 376 -2900 • Fax: 800 - 889 -9904 Toll Free: 800 - 433 -4822 ( #3 ) www.mehvac.com Specifications are subject to change without notice. EX. FULL WEIGHT INSULATED DEMISING WALL 12'X12' f 12'Xi2' - . ti,8mv. rve•i• .;ca 9'X 12' 7 NEW STATIC GUARD VCT SERVER 6N I ec t 11 claw A.6.....iptavaarzikzwaum ( NEW "MR SLIM" MITSUBISHI WALL NVAC 18' -1 1/8" sx: E v System Model Numbers Indoor Unit Outdoor Units MS -A09WA MU -A09WA MS -Al2WA MU -Al2WA HVAC Guide Specifications Ductless Mini - splits MS Section 15700 — Mechanical HVAC Capacity Range: 0.75 to 1 Ton Nominal Mitsubishi Electric Model Number: MS (wall- mount) Cooling only system with wireless remote controller Part 1 - General 1.01 System Description The air conditioning system shall be a Mitsubishi Electric MS split system series. The system shall consist of a slim silhouette, compact, wall mounted indoor fan coil section with wireless remote controller and a slim silhouette horizontal discharge outdoor unit with constant speed compressor, charged with R410A refrigerant. 1.02 Quality Assurance a) The units shall be tested by a Nationally Recognized Testing Laboratory (NRTL)) and bear the ETL label. b) All wiring shall be in accordance with the National Electrical Code (N.E.C.). c) The units shall be rated in accordance with Air - conditioning Refrigeration Institute's (ARI) Standard 210 and bear the ARI Certification label. d) The units shall be manufactured in a facility registered to ISO 9001 and IS014001 which are a set of standards applying to environmental protection set by the International Standard Organization (ISO). e) A pressure charge of R410A refrigerant sufficient for 25 feet of refrigerant tubing shall be provided in the condensing unit. f) A dry air holding charge shall be provided in the indoor section. g) System efficiency shall meet or exceed 13.0 SEER. 1.03 Delivery, Storage and Handling a) Unit shall be stored and handled according to the manufacturer's recommendation. b)The wireless controller shall be shipped inside the carton with the indoor unit and able to withstand 105 °F storage temperatures and 95% relative humidity without adverse effect. Part 2 - Warranty 2.01 The units shall have a manufacturer's parts and defects warranty for a period one (1) year from the date of the original installation. The compressor shall have a warranty of 6 years from date of installation. If, during this period, any part should fail to function properly due to defects in workmanship or material, it shall be replaced or repaired at the discretion of the manufacturer. This warranty does not include labor. System Model Number Cooling Capacity Btuth TPW SEER CFM (Hi) MS -A09WA 9500 870 13 335 MS -Al2WA 12000 1070 13 406 2.02 Manufacturer shall have over 25 years of continuous experience in the U.S. market. Part 3 - Performance 3.01 Each system shall perform in accordance with the ratings shown in the table below. 3.02 Cooling performance shall be based on 80 °F DB, 67 °F WB (26.7 °C DB, 19.4 °C WB) for the indoor unit and 95 °F DB, 75 °F WB (35 °C DB, 23.9 °C WB) for the outdoor unit: TPW = Total Power Watts. Part 4 — Product 4.0 Indoor Unit General a) The indoor unit shall be factory assembled, wired and run tested. Contained within the unit shall be all factory wiring, internal piping, control circuit board and fan motor. b) The unit shall have a self - diagnostic function, 3- minute time delay mechanism, an auto restart function, an emergency operation function and a test run switch. c) Indoor unit and refrigerant pipes shall be charged with dry air before shipment from the factory. 4.01 Unit Cabinet a) The casing shall have a white finish. b) Multi directional drain and refrigerant piping offering four (4) directions for refrigerant piping and two (2) directions for draining shall be standard. c) There shall be a separate installation plate which secures the unit firmly to the wall. 4.02 Fan a) The indoor unit fan shall be an assembly with a line -flow fan direct driven by a single motor. b) The fan shall be statically and dynamically balanced and run on a motor with permanently lubricated bearings. c) A manual adjustable vertical guide vane shall be provided with the ability to change the airflow from side to side (left to right). d) An integral, motorized air sweep flow louver shall provide an automatic change in airflow by directing the air up and down to provide for uniform air distribution. e) The indoor unit fan motor shall operate in three (3) selectable speeds, High, Medium and Low. 4.03 Filter Return air shall be filtered by means of easily removed Catechin air filter and an anti - allergy enzyme filter — blue bellows type. 4.04 Coil a) The indoor unit (evaporator) coil shall be of nonferrous construction with smooth, pre- coated aluminum fins on copper tubing. b) Tubing shall have inner groves for high efficiency heat exchange c) All tube joints shall be brazed with PhosCopper or silver alloy. d) The coil shall be pressure tested at the factory. e) A sloped condensate pan and drain with extension hose shall be provided under the coil. 4.05 Electrical a) The electrical power of the unit, supplied from the outdoor unit shall be 115 volts, 1 phase, 60 hertz. The system shall be capable of satisfactory operation within voltage limits of 103 volts to 127 volts. b) The unit shall be equipped with Mitsubishi Electric's micro - processor control system directing indoor and outdoor unit coordinated operation by two polarity sensitive control wires. c) The indoor unit shall not have any supplemental electrical heat elements. 4.06 Control a) This system shall have a wireless remote controller to perform input functions necessary to operate the system. The controller shall consist of a Power On/Off switch, Mode Selector, Temperature Setting, Timer Control, Fan Speed Select and Auto Vane Selector. b) Temperature changes shall be by 1°F increments with a range of 65 °F to 87 °F. c) There shall be a 24 hour On/Off timer. d) The unit shall have an emergency operation mode to allow operation without the remote controller. e) The microprocessor located in the indoor unit shall have the capability of sensing return air temperature and indoor coil temperature, receiving and processing commands from the wireless remote controller, providing emergency operation and controlling the outdoor unit. f) The control voltage between the indoor unit and the outdoor unit shall be 115 volts, AC. g) The system shall be capable of automatic restart when power is restored after power interruption. h) The control system shall control the operation of the air sweep louvers, as well as provide on/off and system/mode function switching. 4.07 Outdoor Unit General The outdoor unit is designed specifically for use with MS series indoor units. These units are equipped with a circuit board that interfaces to the MS indoor unit circuit board. The outdoor unit shall be completely factory assembled, internally piped and wired. Each unit shall be run tested at the factory. 4.08 Unit Cabinet a) The casing shall be fabricated from zinc coated steel, bonderized with an electrostatically applied, thermally bonded, acrylic or polyester powder coating for corrosion protection. b) Case and mounting feet shall be as follows: The MS -A09WA base shall be of Aluminum- Zinc - Magnesium alloy coated steel, with welded mounting feet. feet. The base for the MS -Al2WA shall have a galvanized steel base with welded mounting 4.09 Fan a) The unit shall be furnished with a direct drive propeller type fan, statically and dynamically balanced for smooth and quiet operation. b) The fan motor shall have inherent protection, be equipped with permanently lubricated bearings. The fan motor shall be mounted and isolated for quiet operation. c) The fan shall be provided with a raised guard to prevent contact with moving parts. d) The outdoor unit shall have horizontal discharge airflow. 4.10 Coil a) The condenser coil shall be of nonferrous construction with pre- coated aluminum strake fins on copper tubing. b) The coil shall be protected with an integral metal guard. c) Refrigerant flow from the condenser shall be controlled by means of a metering orifice. 4.11 Compressor a) The compressor shall be a Mitsubishi Electric high performance, hermetic, rolling piston, rotary type. b) Compressor shall be mounted using rubber isolating bushings to avoid the transmission of vibration. c) Compressor shall be protected by an automatic over current relay and a thermal overload switch 4.12 Operation a) The outdoor unit shall have an accumulator. b) The outdoor unit must have the ability to operate with a maximum height difference of 35 feet between indoor and outdoor units. c) The unit shall have a maximum refrigerant tubing length of 65 feet between indoor and outdoor units without the need for line size changes, traps or additional oil. d) The unit shall be pre- charged for a maximum of 25 feet of refrigerant tubing. 4.13 Electrical a) The electrical power of the system shall be 115 volts, 1 phase, 60 hertz. The unit shall be capable of satisfactory operation within voltage limits of 103 volts to 127 volts. b) The outdoor unit shall be controlled by the microprocessor located in the indoor unit. The control voltage between the indoor unit and the outdoor unit shall be 115 volts, AC. Mr. Slim MS Series Guide Specification ©2007 Mitsubishi Electric / HVAC System Model Numbers Indoor Unit Outdoor Units MS -A09WA MU -A09WA MS -Al2WA MU -Al2WA HVAC Guide Specifications Ductless Mini - splits MS Section 15700 — Mechanical HVAC Capacity Range: 0.75 to 1 Ton Nominal Mitsubishi Electric Model Number: MS (wall- mount) Cooling only system with wireless remote controller Part 1 - General 1.01 System Description The air conditioning system shall be a Mitsubishi Electric MS split system series. The system shall consist of a slim silhouette, compact, wall mounted indoor fan coil section with wireless remote controller and a slim silhouette horizontal discharge outdoor unit with constant speed compressor, charged with R410A refrigerant. 1.02 Quality Assurance a) The units shall be tested by a Nationally Recognized Testing Laboratory (NRTL)) and bear the ETL label. b) All wiring shall be in accordance with the National Electrical Code (N.E.C.). c) The units shall be rated in accordance with Air - conditioning Refrigeration Institute's (ARI) Standard 210 and bear the ARI Certification label. d) The units shall be manufactured in a facility registered to ISO 9001 and ISO14001 which are a set of standards applying to environmental protection set by the International Standard Organization (ISO). e) A pressure charge of R410A refrigerant sufficient for 25 feet of refrigerant tubing shall be provided in the condensing unit. f) A dry air holding charge shall be provided in the indoor section. g) System efficiency shall meet or exceed 13.0 SEER. 1.03 Delivery, Storage and Handling a) Unit shall be stored and handled according to the manufacturer's recommendation. b)The wireless controller shall be shipped inside the carton with the indoor unit and able to withstand 105 °F storage temperatures and 95% relative humidity without adverse effect. Part 2 - Warranty 2.01 The units shall have a manufacturer's parts and defects warranty for a period one (1) year from the date of the original installation. The compressor shall have a warranty of 6 years from date of installation. If, during this period, any part should fail to function properly due to defects in workmanship or material, it shall be replaced or repaired at the discretion of the manufacturer. This warranty does not include labor. System Model Number Cooling Capacity Btu/h TPW SEER CFM (Hi) MS -A09WA 9500 870 13 335 MS -Al2WA 12000 1070 13 406 2.02 Manufacturer shall have over 25 years of continuous experience in the U.S. market. Part 3 - Performance 3.01 Each system shall perform in accordance with the ratings shown in the table below. 3.02 Cooling performance shall be based on 80 °F DB, 67 °F WB (26.7 °C DB, 19.4 °C WB) for the indoor unit and 95 °F DB, 75 °F WB (35 °C DB, 23.9 °C WB) for the outdoor unit: TPW = Total Power Watts. Part 4 — Product 4.0 Indoor Unit General a) The indoor unit shall be factory assembled, wired and run tested. Contained within the unit shall be all factory wiring, internal piping, control circuit board and fan motor. b) The unit shall have a self - diagnostic function, 3- minute time delay mechanism, an auto restart function, an emergency operation function and a test run switch. c) Indoor unit and refrigerant pipes shall be charged with dry air before shipment from the factory. 4.01 Unit Cabinet a) The casing shall have a white finish. b) Multi directional drain and refrigerant piping offering four (4) directions for refrigerant piping and two (2) directions for draining shall be standard. c) There shall be a separate installation plate which secures the unit firmly to the wall. 4.02 Fan a) The indoor unit fan shall be an assembly with a line -flow fan direct driven by a single motor. b) The fan shall be statically and dynamically balanced and run on a motor with permanently lubricated bearings. c) A manual adjustable vertical guide vane shall be provided with the ability to change the airflow from side to side (left to right). d) An integral, motorized air sweep flow louver shall provide an automatic change in airflow by directing the air up and down to provide for uniform air distribution. e) The indoor unit fan motor shall operate in three (3) selectable speeds, High, Medium and Low. 4.03 Filter Return air shall be filtered by means of easily removed Catechin air filter and an anti - allergy enzyme filter — blue bellows type. 4.04 Coil a) The indoor unit (evaporator) coil shall be of nonferrous construction with smooth, pre- coated aluminum fins on copper tubing. b) Tubing shall have inner groves for high efficiency heat exchange c) All tube joints shall be brazed with PhosCopper or silver alloy. d) The coil shall be pressure tested at the factory. e) A sloped condensate pan and drain with extension hose shall be provided under the coil. 4.05 Electrical a) The electrical power of the unit, supplied from the outdoor unit shall be 115 volts, 1 phase, 60 hertz. The system shall be capable of satisfactory operation within voltage limits of 103 volts to 127 volts. b) The unit shall be equipped with Mitsubishi Electric's micro - processor control system directing indoor and outdoor unit coordinated operation by two polarity sensitive control wires. c) The indoor unit shall not have any supplemental electrical heat elements. 4.06 Control a) This system shall have a wireless remote controller to perform input functions necessary to operate the system. The controller shall consist of a Power On/Off switch, Mode Selector, Temperature Setting, Timer Control, Fan Speed Select and Auto Vane Selector. b) Temperature changes shall be by 1 °F increments with a range of 65 °F to 87 °F. c) There shall be a 24 hour On/Off timer. d) The unit shall have an emergency operation mode to allow operation without the remote controller. e) The microprocessor located in the indoor unit shall have the capability of sensing return air temperature and indoor coil temperature, receiving and processing commands from the wireless remote controller, providing emergency operation and controlling the outdoor unit. 0 The control voltage between the indoor unit and the outdoor unit shall be115 volts, AC. g) The system shall be capable of automatic restart when power is restored after power interruption. h) The control system shall control the operation of the air sweep louvers, as well as provide on/off and system/mode function switching. 4.07 Outdoor Unit General The outdoor unit is designed specifically for use with MS series indoor units. These units are equipped with a circuit board that interfaces to the MS indoor unit circuit board. The outdoor unit shall be completely factory assembled, internally piped and wired. Each unit shall be run tested at the factory. 4.08 Unit Cabinet a) The casing shall be fabricated from zinc coated steel, bonderized with an electrostatically applied, thermally bonded, acrylic or polyester powder coating for corrosion protection. b) Case and mounting feet shall be as follows: The MS -A09WA base shall be of Aluminum- Zinc - Magnesium alloy coated steel, with welded mounting feet. feet. The base for the MS -A 1 2WA shall have a galvanized steel base with welded mounting 4.09 Fan a) The unit shall be furnished with a direct drive propeller type fan, statically and dynamically balanced for smooth and quiet operation. b) The fan motor shall have inherent protection, be equipped with permanently lubricated bearings. The fan motor shall be mounted and isolated for quiet operation. c) The fan shall be provided with a raised guard to prevent contact with moving parts. d) The outdoor unit shall have horizontal discharge airflow. 4.10 Coil a) The condenser coil shall be of nonferrous construction with pre- coated aluminum strake fins on copper tubing. b) The coil shall be protected with an integral metal guard. c) Refrigerant flow from the condenser shall be controlled by means of a metering orifice. 4.11 Compressor a) The compressor shall be a Mitsubishi Electric high performance, hermetic, rolling piston, rotary type. b) Compressor shall be mounted using rubber isolating bushings to avoid the transmission of vibration. c) Compressor shall be protected by an automatic over current relay and a thermal overload switch 4.12 Operation a) The outdoor unit shall have an accumulator. b) The outdoor unit must have the ability to operate with a maximum height difference of 35 feet between indoor and outdoor units. c) The unit shall have a maximum refrigerant tubing length of 65 feet between indoor and outdoor units without the need for line size changes, traps or additional oil. d) The unit shall be pre - charged for a maximum of 25 feet of refrigerant tubing. 4.13 Electrical a) The electrical power of the system shall be 115 volts, 1 phase, 60 hertz. The unit shall be capable of satisfactory operation within voltage limits of 103 volts to 127 volts. b) The outdoor unit shall be controlled by the microprocessor located in the indoor unit. The control voltage between the indoor unit and the outdoor unit shall be 115 volts, AC. Mr. Slim MS Series Guide Specification 02007 Mitsubishi Electric / HVAC ACTIVITY NUMBER: M08 -268 PROJECT NAME: GAMEFLY SITE ADDRESS: 12783 GATEWAY DR X Original Plan Submittal Response to Correction Letter # DEPARTMENTS: I GI +,�p� �I 104 JI ,� 4 `f 1 B I ng ivision LE Fire Prevention Public Works Complete Documents/routing slip.doc 2 -28 -02 PEt• : MIT COORD COPY • PLAN REVIEW /ROUTING SLIP ❑ Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Incomplete DATE: 11 -06 -08 Response to Incomplete Letter # Revision # After Permit Issued Planning Division DUE DATE: 11 -11 -08 DATE: Not Applicable Comments: TUES/THURS RO TING: Please Route Structural Review Required ❑ No further Review Required Permit CenteriUse OM . '. ` `, � �' ' �:c ' : s '"" • • Y a .�tr+7• q x.:'::� iS •• y ' . � kyAa•. ' •. • ,_>.v • rid .-_ �•x�i' -'-' :r. Y . •..'�J- '.'.h�` x'e�Slo�.dcySk { : i,}�ie . { "yR�'n•S�.r��..:.• � erh��' :' .:L.v +ti..''• �.u'i.'': INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DUE DATE: 12 -09 -08 Approved ❑ Approved with Conditions 4 Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Pe►initCeiite� ?!%se {On'1 ' ".., . - •!• •Fi `• 7'• • Y ,;, f3e•, =':yc: � .. .. � v., ., - x . � :} ''a• . r _• r: ' ;•.ti ry.'� '"n :' <!: • "'-3 F •'.. � . . CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Bond Company Policy Effective Expiration Cancel Impaired Bond Amount Received Insurance Name Number Date Date Date Date Amount Date FEDERATED 2 MUTUAL 9821065 08/01/2008 08/01/2009 $1,000,000.00 06/16/2008 INS 1 CBIC C11SH5647 10/08/2007 10/08/2008 $1,000,000.00 10/17/2007 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 CBIC SH5647 10/08/2007 Until Cancelled $6,000.00 10/17/2007 Name Role Effective Date Expiration Date YATSUK, ROMAN OWNER 10/17/2007 Untitled Page General /Specialty Contractor A business registered as a construction contractor with Lai to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company SEATTLE MECHANICAL 4252313123 5805 -A GLENWOOD AVE EVERETT WA 98203 SNOHOMISH INDIVIDUAL UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 602771144 ACTIVE SEATTM*932PP CONSTRUCTION CONTRACTOR 10/17/2007 10/17/2009 HTG /VENT /AIR CONDITIONING UNUSED Business Owner Information Bond Information Insurance Information • I Page 1 of 1 https: / /fortress.wa. gov /lni/bbip/Detail. aspx ?License= SEATTM* 932PP 12/03/2008 E uipment Schedule (new) Tag _ Make Model CFM Cooling Heating OA CFM V /Ph SOUND RATING UNIT WEIGHT EER Net BTU'S AFUE db's AC-1 13 SEER 12,000 208/1 52 96 MITSUBISHI MS-Al2WA 400 208/1 45 23 N. SYSTEM DE$CRIPTI.OIN PROVIDE NEW MITSUBISHI MR SLIM WALL MOUNTED SPLIT SYSTEM NC FOR NEW SERVER ROOM. 89'-3" ( M q r� ® _. 78' —1 7/8" NORTH FLOOR P AN SCALE: 1/16"= l' -0" 10-13-08 REV TEN. 10 -24 -08 LEGEND FOUR -PLEX OUTLET : DUPLEX OUTLET F1 NOT USED 4 3 /B'LAG BOLTS INTO SLEEPER TO HOLD DOWN CONDENSER TO SLEEPERS NEW 4X4 WOOD SLEEPER T ROOF EXISTING WALL NEW STEEL STUD WALL TO UNDERSIDE OF CEILING W/ SOUND INSULATION EXISTING WALL TO BE REMOVED. NEW DOOR EXISTING DOOR WALL TELEPHONE OUTLET AND DATA, MUDRING, CONDUIT AND PULL STRING ONLY. EXHAUST FAN J -BOX FOR POWER AND /OR PHONE ILLUMINATED EXIT SIGN W/ PATHWAY LIGHTING & BATTERY BACKUP I RECESSED 2X4 -2 TUBE FLUORESCENT 66 WATT LIGHT FIXTURE W/ PARABOLIC LENSE RECESSED 2X2 -2 TUBE FLUORESCENT 66 WATT LIGHT FIXTURE W/ PARABOLIC LENSE SURFACE MOUNT 2 TUBE FLUORESCENT 66 WATT LIGHT FIXTURE 0 RECESSED COMPACT FLUORESCENT LIGHT FIXTURE, 32 WATTS E EXISTING N NEW D DEDICATED SWITCH WALL TYPES (SI =SOUND INSULATE) 2 3- 1/2'X25 GA. STL. STUD 0 24' O.C. TO ACOUSTICAL CEILING, GYP. BD. BOTH SIDES 3 NOT USED ENERGY CODE NOTES 1) HEAT IS VIA GAS, NO ELECTRIC HEAT ALLOWED 2) PROVIDE VAPOR ON ALL WALL TO THE WARM SIDE 3) CAULK AND SEAL ALL OPENINGS TO OUTSIDE OR UNHEATED SPACES INCLUDING WEATHER- STRIPPING AT ALL EXTERIOR DOORS. 4 MAXIMUM ALLOWABLE LOAD FOR SWITCH IS 80% OF 20 AMP CIRCUIT. PROVIDE DUAL LEVEL SWITCHING IN ALL ROOMS ADJACENT TO EXTERIOR 5) WINDOWS 6) NO CHANGE TO EXTERIOR ENVELOPE 4X12 PERLINS NEW AC ONDENSER MINI SPLIT CONDESER ROOF DETAIL NTS TWO 3/8' LAG BOLTS FOR EACH SLEEPER TO PERLINS BELOW. KLvityvl:lil rut( CODE COMPLIANCE APPROVED NOV 1 8 2003 City Of Tukwila ItDIN _DIVI rON MO82 2198 RECEWFT NOV 06 2008 PERMIT CENTER w o 0 U, c 03 0 0 0 w I a)CD N 0) 0) I I CID a) 0) z Q Zz �- o o Z 0 et co D Q) : 0J<rn ;() l cn �-�-I H .F4 U) Ro 1> qz.2, z C E- Cf) z 0 r14 E ceD M - NOR1H SITE PLAN VICINITY MAP AR =A OF WOR 1 ) 2) 3) 4) 5) 6) LEGAL DESCRIPTION 6 GATEWAY CORPRETE CENTER TAX ID. NUMBER 2716000060-0060-08 SCOPE OF WORK CONSTRUCT NEW NONBEARING WALLS. BUILDING ENVELOPE NOT CHANGED. BUILDING & SIT'E STATISTICS BUILDING CODE: IBC 2004 - ZONING: C /LI -TYPE OF CONSTRUCTION: V -B SPRINKLERED - OVERALL BUILDING FOOTPRINT: 41,077 S.F. - TENANT AREA THIS PERMIT WAREHOUSE: 8,268 S.F. OFFICE: 2,127 S.F. TOTAL: 11,395 S.F. OCCUPANCY GROUP: S -1 & B ENERGY CODE NOTES HEAT IS VIA GAS, NO ELECTRIC HEAT ALLOWED -NO CHANGE TO ENVELOPE PROVIDE VAPOR ON ALL WALL TO THE WARM SIDE , CAULK AND SEAL ALL OPENINGS TO OUTSIDE OR UNHEATED SPACES INCLUDING WEATHER- STRIPPING AT ALL EXTERIOR DOORS. MAXIMUM ALLOWABLE LOAD FOR SWITCH IS 80% OF 20 AMP CIRCUIT PROVIDE DUAL LEVEL SWITCHING IN ALL ROOMS ADJACENT TO EXTERIOR WINDOES LESS THAN 60% OF THE FIXTURES ARE NEW INSTALLED WATTAGE NOT INCREASED AND SPACE USE NOT CHANGED, ALTERATION EXPANSION t(LV1.0\id) rUK CODE COMPLIANCE APPROVED NOV 1 82l1B Of Tukwila YN5 DIVISION- s hall bema detothe �i oh ithou - of work �► t prior approval Division. Tukwila Building � new plan tees. submittal Ho : y nl ude additional P Revisions Will require Ian r and may incl FCtm Permit No. AAQ? 5 Ilr review approval Is subject to errors and omissions Approval of construction documents does not authorize. the violation of any adopted code or ordinance. Ftece.ipt 01 approved Field Copy and conditions is_actsrto lected: By Date: City o1 Tukwila F31JILDING D "v SI N MO8 RECEIVED NOV 016 2008 PERMIT CENTER 0 03 O oo 4 U, T 2 U LO O co rn rn I I P 0) 0) L z 0 o ? W a CO S j 0 0 C 0