Loading...
HomeMy WebLinkAboutPermit M08-271 - PITA PITPITA PIT 381 STRANDER BL M08 -271 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: 381 STRANDER BL TUKW Contractor License No: PLATEM *008PU Value of Mechanical: $10,000.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial Citylif Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PITA PIT 381 STRANDER BL , TUKVVILA WA GREG BROWN PO BOX 143 , ENUMCLAW WA PLATEAU MECHANICAL PO BOX 143 , ENUMCLAW WA MECHANICAL PERMIT DESCRIPTION OF WORK: INSTALL TYPE I HOOD WITH DUCTWORK AND HVAC DUCT DISTRIBUTION EQUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 0 0 0 0 0 1 0 0 * *continued on next page ** • Permit Number: Issue Date: Permit Expires On: Phone: Phone: 360 -802 -4396 Phone: 360 802 -4396 Expiration Date: 10/30/2010 M08 -271 11/26/2008 OS/19/2009 Fees Collected: $282.50 International Mechanical Code Edition: 2006 Boiler Compressor: 0-3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 8 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment doc: IMC-10/06 M08 -271 Printed: 11 -26 -2008 Permit Center Authorized Signature: Signature: Print Name: doc: I MC -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us r c • Permit Number: M08 -271 Issue Date: 11/26/2008 Permit Expires On: 05/19/2009 Date: 0-62 1/17/ I hereby certify that I have read and ed - permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the erf; j�� . ce of work. I am authorized to sign and obtain this mechanical permit. Date: ! l CO��u This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M08 -271 Printed: 11 -26 -2008 Parcel No.: Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 381 STRANDER BL TUKW PITA PIT 1: ** *BUILDING DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS • Permit Number: M08 -271 Status: ISSUED Applied Date: 11/12/2008 Issue Date: 11/26/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 6: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: A Type 1 hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Each required commercial kitchen exhaust hood and duct system required by section 610 of the International Fire Code to have a Type 1 hood shall be protected with an approved automatic fire - extinguishing system installed in accordance with this code. (IFC 610.2, IFC 904.2.1 and IFC 904.11) Automatic fire - extinguishing systems shall comply with UL 300 or other equivalent standards and shall be installed in accordance with the requirements of the listing. (NFPA 96, 10.2.3) doc: Cond -10/06 M08 -271 Printed: 11 -26 -2008 S City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 14: Type I hood systems shall be designed and installed to automatically activate the exhaust fan whenever cooking operations occur. The activation of the exhaust fan shall occur through an interlock with the cooking appliances, by means of heat sensors or by means of other approved methods. (IMC 507.2.1.1) 15: U.L. central station supervision is required. (City Ordinance #2050) • 16: All new automatic fire - extinguishing systems and all modifications to existing automatic fire - extinguishing systems shall have fire department review and approval of drawings prior to installation or modification. 17: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 18: An electrical permit from the City of Tukwila Building Department Permit Center (206 - 431 -3670) is required for this project. 19: Portable fire extinguishers shall be provided within a 30 -foot (9144 mm) travel distance of commercial -type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. (IFC 904.11.5) 20: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 21: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 22: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4-3, 4 -4) 23: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 24: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 25: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** doc: Cond -10/06 M08 -271 Printed: 11 -26 -2008 Signature: Print Name: • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. 7 re gro-uszfri . Date: / f doc: Cond -10/06 M08 -271 Printed: 11 -26 -2008 Site Address: Tenant Name: CITY OF TUKWIL, Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.cLtukwila.wa.us Property Owners Name: ✓3 Z F .J' Mailing Address: 1 5'.a Name: C EC- (31 Mailing Address: P - ga,k I `l 3 E -Mail Address: T A + m e .1. L ¥cc a d 1. Company Name: Mailing Address: Company Name: Mailing Address: Contact Person: E -Mail Address: MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** B1 5TRAl.I R Peru S' , \ J ( L L 1 tZ 15 Po.,( P N�PLCha ., 1 H'3 iZ O t3 LW Contact Person: 6/ cc\ G E -Mail Address: plG e L t'45 �c) O o 1 Contractor Registration Number: ? I A 4 * 003 Pv C A Mechanical Permit No. Project No. S O S ~ l SO (For -office use only) King Co Assessor's Tax No.: a (0 2 3cd 9 p Co '-( Suite Number: New Tenant: ! 4 6 n City Day Telephone: 3 (' o -o ' ti 3 9 nvvt -+c \aw City Fax Number: 3(4 Ex) uW'c I mo«,, City Day Telephone: Fax Number: Expiration Date: City State State Fc3a /U /31 i o 8- 7- ? Floor: .... Yes [] ..No 9 �1oS 8 Zip �i$o2 2 Zip Li35c, State Zip 3(06 FO• 4 /3 9 (0 3 (6C - o 1 y39b cJ �s 1$O 75 State Zip Day Telephone: y e s 39 I °� 3.). 1 Fax Number: y . 5 t .2 75 Company Name: Mailing Address: (()1 0 Contact Person: E -Mail Address: ?ltt5t ,, NVer Q: W pplications\Forms- Applications On LineU.2006 - Mechanical Permit Application.doc Revised: 4 -2006 bh 51/4,;c. Say City Day Telephone: Fax Number: 1 , ( ofts, 0 State 61(,) Zip '63 ? 877 3c)3 7 71 8333 Page 1 of 2 Unit Type:, Qty Unit Type: Qty Un tType: . �� Boi,Cer: /Compressor.: Qty Furnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Fumace>100K BTU Evaporator Cooler Diffuser B 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct I Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator — Comm/Ind Other Mechanical Equipment Valuation of Project (contractor's bid price): $ Id r)a0 Scope of Work (please provide detailed information): IN s "TALL T T p e aN Q ►�cyfl- , i T 1 1 n a(u c - o r \ C a ,, ,, d l i•AV A C r u u c T O t A5 - r 2 r e3 (..) 5) 0 Use: Residential: New .... Replacement .... Commercial: New .... Replacement .... 0 Fuel Type: Electric Gas .... Indicate type of mechanical work being installed and the quantity below: °PERMIT APPLICATION NOTES- Applicable'to all permits in this application 4. q z - c ti � C` 0, ar„d [�6a.. bra . ,, ':a D ow^ � Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER Q,i�ED AGENT: Signature: 1 Print Name: l`zee r Bfowh Mailing Address: et). ), 1 3 Date Application Expires: Date Application Accepted: 11_1) - -0g/ Q:1 Applications\Forms- Applications On Linel3.2006 - Mechanical Permit Application.doc Revised: 4-2006 bh Other: Date: // / .2J6 Y Day Telephone: %d 80;2 V3 city 0--Jo‘ State 5'Soa a Zip Staff Initials: Gli Page 2 of 2 i Parcel No.: Address: 381 STRANDER BL TUKW Suite No: Applicant: PITA PIT Receipt No.: R08 -03743 Initials: WER User ID: 1655 Payee: PLATEAU MECHANICAL ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http : / /www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 4091 282.50 RECEIPT Account Code Current Pmts 000.322.102.00.0 226.00 000/345.830 56.50 Total: $282.50 Permit Number: M08 - 271 Status: PENDING Applied Date: 11/12/2008 Issue Date: Payment Amount: $282.50 Payment Date: 11/12/2008 02:08 PM Balance: $0.00 doc: Receiot -06 Printed: 11 -12 -2008 Projec , ^ p i I V t Type of jrtspectio n_ - NV Address: 3n 1 Stf �� ate Called: .--- Special Instructions: D 7 1 L, /1 - 6 ( Date Wanted: Requester: Phone 3 -307-61( D (I INSPECTION RECORD Retain a copy with permit PERMIT NO. p L . Md$ -2-7I INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 'Approved per applicable codes. Corrections required prior to approval. COMMENTS: I Inspecto Date: 2 1 _ 05 ❑ $60.00 REINSPECTION FEE REQUIRED Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: COMMENTS: Type of Ins ection: A. / / J ..„o f Address; J8/ ..._ 7fl — 3- ef1S ;/1 5M1( 4 :I - 11 r 4 .c 1... - ,1 ( � _. 7Th- w I � a A • 1) A) f-,,-,,a p.m. Requester: Phone No: a2s3e - 7 - Y66 Project;...-, � / ,- ..9 / Type of Ins ection: A. / ( , v Address; J8/ ..._ 7fl Date Called: Special Instructions: Date Wanted: D5 p.m. Requester: Phone No: a2s3e - 7 - Y66 -4* INSPECTI0ON0. Approved per applicable codes. Inspector INSPECTION RECORD Retain a copy with permit PERMIT NO. me-2 7// CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -870 Corrections required prior to approval. Date: ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: COMMENTS: g A-Vi Tt d o ti A LA .rr ,7i ` r - o d I d se 7 A- r - � -- G , a io ' i'p(.‘ ___ toff .4 2(A-- ) F f (JA-; (C SJir (ter Ak /kP 1 ,.---"Th Special Instructions: AJi. � - (-,, ea -P ,1 a re Date Wanted: , 1 2 I ' /, o V �� p.m. Requester: Project: ---- Type of Inspection ► Addsr . i � j _ 1� I l� ,, Date Called: ,.---"Th Special Instructions: Date Wanted: , 1 2 I ' /, o V �� p.m. Requester: Phone Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Nvog --2 PERMIT NO. (206)431 -3670 Corrections required prior to approval. Inspect Date: ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be . paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project Type of Inspection: Address 3 �k - - \ A aG Date clled: Special Instructions: Date Wanted: 0 9 1....— (RM.- p.m. Requester: Phone No: � 3-1 00 3 JNSPECTION RECORD V Retain a copy with permit INSPECTION NO. (Y1 Oa -27 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION + 6300 Southcenter Blvd., #1 00, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. Receipt No.: 'Date: $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Project: MA f a Typkj of Inspection:. �,u6h , n /ra .. . , Address: Xe 916k *,1 ./ Date Called: nal Instructions: Date Wanted: a.m. f Qr 4 p.m. quester: e/ Ph 3/31.g53 El Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTIO NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 r (206)431 -3670 Corrections required prior to approval. COMMENTS: Inspector: Date: ' -2-a - f t rr t sg, -e.-S a $60.00 REINSPECTION FEE REQ I ED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. R eceipt No.: 'Date: «1_ COMMENTS: Sprinklers: y Type of Inspection: /116e /1 . i ',L. Contact Person: Special Instructions: Occupancy Type: WI - 7 7 ) - i_:_..x / L 4, 7 c71 Pi 4) PI 0 / - (7 - ; ( 0 { c: l fri 4 VL • b ,--- i ,- - , -- L l / ) Al 1 .")// 1 /& - • "51-i pa Al 1'2i- tr- L- -- 67 icutii4iyr Ze.),41 .1.) - Project: d i---fp, gr. Sprinklers: y Type of Inspection: /116e /1 Address: .3,t)/ .'• r), Suite #: i ',L. Contact Person: Special Instructions: Occupancy Type: WI - 7 7 ) - Phone No.: Needs Shift Inspection: i-1/;trii 7 h 1 7 / Sprinklers: y Fire Alarm: / Hood & Duct: y Monitor: 4 (; . Pre-Fire: j,ii,' 7,0 ,q---r Permits: / Occupancy Type: WI - 7 7 ) - INSPECTION NUMBER Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Corrections required prior to approval. Date: Hrs.: P -.- Inspector: n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word/Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 COM ENTS: Fire Alarm: Hood & Duct: Address: ?' 5, pi Y - e. Suite #: Contact Person: Afr 1 Occupancy Type: Special Instructions: Phone No.: , 3 / 4 1/& 0 I 1-/00) __ AZ L .a , A,nr - h . 3t d t t 0 (' 61 r -/t✓L,t - t w ~ 7` _ -J c.:...> 0 rr 7 , .V ?{9? J : •! 1 1 /) W .' i;l ;:l,/ "1 -i.:2z- 77/f( t. - ‘> IC- .,... Project: /7r) P Type of Inspection: 1/9 - ijoo Fire Alarm: Hood & Duct: Address: ?' 5, pi Y - e. Suite #: Contact Person: Afr Permits: Occupancy Type: Special Instructions: Phone No.: , 3 / 4 1/& 0 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER Approved per applicable codes. INSPECTION RECORD Retain a copy with permit PER IT NUMBERS - S- 53 CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Corrections required prior to approval. Inspector: ;) wa 91- Date: 2 J j Hrs.: G` $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 MAYES TESTING ENGINEERS, INC. k. MTE NO: PROJECT: Address: T09003 PITA PIT — PLATEAU MECHANICAL 381 Strander Boulevard Tukwila, WA PERMIT NO: M08 -271 Page 1 Owner: Brent Palmer Architect: Will Harris Architects Engineer: Priest Engineering Contractor: Plateau Mechanical Date: 1 -5 -09 Weather: Overcast Inspection: Structural Steel Samples: N/A A MTE inspector arrived onsite for inspection of welding hood vent duct above the stove. Inspected seam welds on duct extension. Welding was inspected per AWS D1.3 and is acceptable per AWS visual acceptance criteria. To the best of our knowledge, all items inspected this date are in accordance with approved plans and specifications. cc: Greg Brown, Plateau Mechanical — Building Official. City of Tukwila FEB 0 3 2009 C OMMUNITY PEVELOPMENT INSPECTOR: Jonathan Peters Reviewed by• . Shaun W. Sevi • i ranch Manager Lynnwood Office 20225 Cedar Valley Road Suite 110 Lynnwood, WA 98036 ph 425.742.9360 fax 425.745.1737 Tacoma Office 10029 S. Tacoma Way Suite E -2 Tacoma, WA 98499 ph 253.584.3720 fax 253.584.3707 Portland Office 7911 NE 33rd Drive Suite 190 Portland, OR 97211 ph 503.281.7515 fax 503.281.7579 • Fire Barrier Duet Wra p 15A Duct Wrap Fire Protection Systems for Commercial Kitchen Grease and Chemical Fume Exhaust Ducts FILE' COPS KtvIttvtu rUtk Co DE CD"p APP" NOV 2 02 Product %Val a I Installation -- -Instructions BATTS AND BLANKETS EOM USE IN FIRE RESISTIVE DUCT ASSEMBLIES SEE UL DIRECTORY OF PRODUCTS CEPTIEFD FOP CANADA AND SEE UT F RE RESISTANCE DIRECTORY 9069 SSIP4 US C US DUCT WRAP MATERIALS TOR USE IN THROUGH- PENETRATION FIRE STOP SYSTEMS SEE UT DIRECTORY Cr °900'UCTS CERTIFIED TOM CANADA AND JI TIRE RESISTANCE DIRECTORY 9069 O GA Po ES 2161 Compliance Report 2132A flog - z:7 1 NFPA 96 Complies with Complies with Compliance International Standard 1998 Edition Mechanical Code Mechanical Code • RECEIVED NOV • 2. PERMIT CENTER Fire Resistive Rating Enclosure System Omega Point Lab. Duct System Design Nos. Through - Penetration System 1 or 2 hours 1 layer of 3M Fire Barrier GD 532 F 15A FS 557 W 1 Duct Wrap 15A , 3 in. GD 538 F 15A FS 558 F 1.5 in. x 48 in. x 20 ft. (38mm x 121 cm x 609 cm) (76 mm) perimeter and GD 547 F 15A FS 559 W longitudinal overlaps GD 548 F 15A FS 560 F GD 549 F 15A FS 561 F GD 556 F 15A FS 562 W GD 557 F 15A FS 563 W FS 578 F FS 579 W Product Unit Size Units/ ctn. Wt./ ctn. 3M Fire Barrier Duct Wrap 15A Roll 1.5 in.x 24 in. x 20 ft. (38mm x 60,9cm x 609 cm) 1 53 lbs. 24 kg 3M Fire Barrier Duct Wrap 15A Roll 1.5 in. x 48 in. x 20 ft. (38mm x 121 cm x 609 cm) 1 106 lbs. 48 kg 1. Product Description 3MTM Fire Barrier Duct Wrap 15A is a fire resistant wrap consisting of a patented inorganic blanket encapsulated with a scrim - reinforced foil. It is used to fire rate commercial kitchen grease ducts and is a proven alternative to 1 or 2 hour fire resistant rated shaft enclosures. This mold resistant * *, non - asbestos wrap contains a safer fiber construction* and installs easily because of its high flexibiltiy and strength. 3M Fire Barrier Duct Wrap 15A is a single layer fire resist- ant wrap that has passed the UL1978 test which sim- ulates a grease duct fire. With its excellent insulating capabilities, it is an ideal choice for tight spaces because it protects combustible constructions at zero clearance throughout the entire enclosure system. 3M Fire Barrier 1000 N /S, 1003 S/L and 2000+ Silicone Sealants used in combination 3M Fire Barrier Duct Wrap 15A provide an effective firestop when the duct penetrates fire rated walls and floors. Features • One layer wrap for grease ducts rated as a shaft alternative per UL 1978 • Zero clearance to combustibles throughout the entire enclosure system for congested spaces • High flexibility for installation ease • Foil encapsulated with unique center overlap seam for blanket protection, less dust, and high wrap strength • Safer fiber construction* • Mold resistant in accordance with ASTM C1338- 00 *Has been demonstrated to be soluble in the lungs according to EU guidelines 67/548/EWG, Note Q for bio persistence. * *Standard Test Method for Determining Fungi Resistance of Insulation Materials and Facings 2. Applications 3M Fire Barrier Duct Wrap 15A is an ideal fire resistive enclosure for commercial kitchen grease ducts. It is a proven performance alternative to a 1 or 2 hour fire resistant rated shaft enclosures and provides zero clearance to combustible construction throughout the entire enclosure system. 3M Fire Barrier 1000 N /S, 1003 S/L or 2000+ Silicone Sealant is used in combination with 3M Fire Barrier Duct Wrap 15A to firestop the duct when the duct penetrates fire rated floors and walls. 3. Availability Page 2 4. Typical Physical Properties Blanket Color: gray /green Weight: 1.38 lbs. /sq. ft. (6.73 kg /sq. m) 5. Performance 3M Fire Barrier Duct Wrap 15A has been tested in accordance with the following: ASTM C 411 ASTM C 51 ASTM C 1338 ASTM E 84 ASTM E 119 ASTM E 136 ASTM E 814 UL 1978 (Sections 12 & 13) Surface Burning Characteristics (ASTM E 84) Foil Encapsulated Blanket: Flame Spread: 0 Smoke Developed: 0 Blanket: Flame Spread: 0 Smoke Developed: 0 Thermal Conductivity Temperature °F ( °C) 500 (260) 1000 (537) 1500 (815) 1800 (982) Grease Duct Listings btu•in. /(hr.•ft 0.417 0.922 1.69 2.27 For technical data and properties of 3M Fire Barrier 1000 N /S, 1003 S/L and 2000+ Silicone Sealants see separate product data sheets available from your 3M representative or go to www.3m.com /firestop. Chemica Exhaust Fume Duct Listings Enclosure System 1 layer of 3M Fire Barrier Duct Wrap 15A , 3 in. (76 mm) perimeter and longitudinal overlaps Duct System CFD500F 15A CFD501F 15A dire Resistive Rating 1 or 2 hours Omega Point Lab. Chemical Through - Penetration System FS 557 W 15A/20A FS 558 F 15A/20A FS 559 W 15A/20A FS 560 F 15A/20A FS 561 F 15A FS 562 W 15A FS 563 W 15A FS 578 F 15A FS 579 F 15A Product Approvals ICC ES Compliance Legacy Report 2161 ICC ES Compliance Legacy Report 2132A New York City MEA; 147 -01 -M California State Fire Marshall; 2440 - 0941:110 Code Compliance 3M Fire Barrier Duct Wrap 15A complies with requirements of the following codes: NFPA 96, 1998 Edition 1997 Standard Mechanical Code 1998/2000 International Mechanical Code 1999 BOCA National Building Code 1999 Standard Building Code This is only a partial list of code compliance. For the latest code and approval information go to www.3m.com /firestop or speak to your authorized 3M distributor or sales representative at (800) 328 -1687. 6. Installation Techniques 3M Fire Barrier Duct Wrap 15A system should be installed in accordance with the following installation instructions. Material and Equipment • 3M Fire Barrier Duct Wrap 15A blanket, 1 -1/2 in. (38 mm) thick, 24 in. (60 cm) or 48 in. (121 cm) wide, 20 ft. (609 cm) standard length. The 48 in. (121 cm) wide blanket helps to minimize waste. • Aluminum foil tape. • Minimum 3/4 in. (19 mm) wide filament tape. • Carbon steel or stainless steel banding material, minimum 1/2 in. (12,7 mm) wide, minimum 0.015 in. (0,38 mm) thick, with steel banding clips. • Hand banding tensioner, crimping tool, and banding cutter. • Minimum 12 gauge copper - coated steel insulation pins; galvanized steel speed clips, minimum 1 -1/2 in. (38 mm) square or 1 -1/2 in. (38 mm) dia. round, or equivalent sized insulated cup -head pins; capacitor discharge stud gun. • Access door hardware: four galvanized steel thread rods, 1/4 in. (6 mm) diameter by 4 -1/2 in. to 5 in. long (114 mm to 127 mm) with 1/4 in. (6 mm) wing nuts and 1/4 in. (6 mm) washers: 4 in. (102 mm) long steel hollow tubing to fit threaded rods. • Minimum 4.0 lb. (1,8 kg) density mineral wool or scrap pieces of 3M Fire Barrier Duct Wrap 15A blanket • 3M Fire Barrier 1000 N /S, 1003 S/L or 2000+ Silicone Sealant. Storage The 3M Fire Barrier Duct Wrap 15A and 3M Fire Barrier 1000 N /S, 1003 S/L and 2000+ Silicone Sealants must be stored in a dry warehouse environment. Pallets should not be stacked. Preparatory Work: 3M Fire Barrier Duct Wrap 15A is installed with common tools, such as knives, banders and capacitor discharge guns for applying insulation pins. In order to install the duct firestop system, the surfaces of all the openings and penetrating items need to be clean, dry, frost free and free of dust. Method: To minimize waste, 3M Fire Barrier Duct Wrap 15A material should be rolled out tautly before measuring. General instructions for installing the 3M Fire Barrier Duct Wrap 15A include a one -layer wrap construction applied directly to the duct. The 3M Fire Barrier Duct Wrap 15A blanket is wrapped around the perimeter of the duct and is cut to a length to overlap itself not less than 3 in. (76 mm). The overlap made by adjacent blankets forms the "longitudinal" overlap. Aluminum foil tape is used to seal all cut edges of the blanket and any tears in the foil scrim. There are three (3) approved installation techniques for installing the 3M Fire Barrier Duct Wrap 15A (See Figures 1A-1D and Figures 2A -2D): 1. Telescoping 3 in. (76 mm) Overlap Wrap With the telescoping overlap wrap method, each blanket overlaps one adjacent blanket, and each blanket has one edge exposed and one edge covered by the next blanket as shown in Figure 1A and 1B. The visible edges of the perimeter overlaps all point in the same direction. 2. Checkerboard 3 in. (76 mm) Overlap Wrap With the 3 in. (76 mm) checkerboard overlap wrap method, blankets with both edges exposed alternate with blankets with covered edges, as shown in Figure 1 C. The visible edges of the perimeter overlaps alternate their directions and appear on every other blanket. 3. Butt Joint With Collar With the butt joint and collar method, adjacent blankets are butted tightly together and 6 in. (152 mm) wide collar of 3M Fire Barrier Duct Wrap is centered over the joint, overlapping each blanket by 3 in. (76 mm) minimum as shown in Figure 1 D. In all three overlap techniques the perimeter overlap can occur at any location on the duct. Page 3 The blanket is mechanically attached to the duct by steel banding or by welded insulation pins and clips for all three installation methods listed above. For Banding Only (See Figures 1A to 1D) Filament tape can be used to temporarily hold the blanket in place until the banding is applied. The steel banding is applied around the duct 1 -1/2 in. (38 mm) from each edge of the blanket, and maximum 10 -1/2 in. (26,7 cm) centers. The banding is placed around the material and tightened so as to sufficiently hold the 3M Fire Barrier Duct Wrap 15A in place against the duct, compressing the foil but not cutting the foil. Additional Pinning to Prevent Sagging of the Wrap: For Ducts 24 in. (60 cm) and larger in width, additional pins are needed to support the blanket on the bottom horizontal surface and on the outside face of a vertical duct run. Space pins a maximum of 10 -1/2 in. (26,7 cm) apart in the direction of the blanket width, and a maximum of 12 in. (30 cm) apart in the direction of the blanket length. Refer to paragraph below for more information on Mechanical Fastening with Pins. For Mechanical Fastening with Pins Only (See Figure 2A to 2D) Insulation pins are welded to the duct in the centers of the overlaps a minimum of 1 -1/2 in. (38 mm) from each edge of the blanket, and spaced a maximum of 10 -1/2 in. (26,7 cm) on center along perimeter overlap, and a maximum of 10 -1/2 in. (26,7 mm) on center along longitudinal overlaps. The blanket is impaled over the pins and held in place by galvanized speed clips. Insulation pins that extend beyond the blanket wrap shall be turned down to eliminate sharp points. Insulated cup -head pins can be used at the same spacing requirements of the insulation pins. NOTE: Support hangar systems do not need to be wrapped provided the hangar rods are at least a minimum of 3/8 in. (9,53 mm) diameter and spaced a maximum of 60 in. (152 cm) on center along the length of the duct. Use a minimum 2 in. x 2 in. x 1/4 in. (50 mm x 50 mm x 6,35 mm) steel angle steel support channel or SMACNA equivalent support system. Access Door Installation (See Figure 3) Four galvanized steel threaded rods, 1/4 in. diameter (6,35 mm) by 4 -1/2 in. to 5 in. long (114 mm to 127 mm) are welded to the duct at the corners of the door opening. Four steel tubes, each 3 in. (76 mm) long, are placed over the rods to act as protection for Page 4 the 3M Fire Barrier Duct Wrap 15A when fastening the door. Four insulation pins are welded to the door panel for installation of the blanket. One layer of 3M Fire Barrier Duct Wrap 15A is cut approximately the same size as the access panel and impaled over the insulation pins on the panel. It is essential that this layer tit tightly against the wrap surrounding the access door opening with no through openings. A second layer of 3M Fire Barrier Duct Wrap 15A is cut so as to overlap the first layer by a minimum of 1 in. (25,4 mm). The second layer is impaled over the pins and both layers are locked in place with galvanized speed clips. Pins that extend beyond the outer layer of 3M Fire Barrier Duct Wrap 15A shall be turned down to avoid sharp points on the door. The insulated door panel is placed over the threaded rods and held in place with washers and wing nuts. The details are shown in Figure 3. Penetrations (See Figures 4A to 4D) When the duct penetrates a fire rated wall, ceiling or floor, an approved firestop system must be employed. Figures 4A to 4D illustrate typical conditions. To firestop the wrapped duct, follow the installation parameters detailed in the following Omega Point Laboratories, Inc. systems: FS 557 W, FS 558 F, FS 559 W, FS 560 F, FS 561 F, FS 562 W, FS 563 W. Other Applications Refer to Figures 5, 6, 7, 8 and 9 for additional typical conditions. Z Maintenance No maintenance is required when installed in accor- dance with the 3M Installation Instructions. Once installed, if any section of the 3M Fire Barrier Duct Wrap 15A is damaged so that the blanket is dam- aged, the following procedures will apply: • The damaged section should be removed by cutting the steel banding or removing the clips holding it in place. • A new section of the same dimension should be cut from a roll of 3M Fire Barrier Duct Wrap 15A, either 24 in. (60,9 cm) or 48 in. (121 cm) wide. • The new section should be placed and fitted ensuring the same overlap that existed previously. • The steel banding should be placed around the material and tensioned so as to sufficiently hold the 3M Fire Barrier Duct Wrap 15A in place. • If the blanket has not been damaged but the foil has ripped, seal the rips with aluminum foil tape. • • • 8. Purchase Information 3M Fire Barrier products are available through a network of nationwide distributors. For information on where to buy, go to www.3m.com /firestop. 9. Safe Handling Information Consult Material Safety Data Sheet prior to handling and disposing of 3M Fire Barrier Duct Wrap 15A. Page 5 1. One Layer 3M Fire Barrier Duct Wrap 15A 2. Steel Banding 1/2 in. (13 mm) Wide Min. Typical 3. 3 in. (76 mm) Min. Longitudinal Overlap 4. 3 in. (76 mm) Min. Perimeter Overlap Figure 1A 3M Fire Barrier Duct Wrap 15A Commercial Kitchen Grease Duct Systems 1 or 2 Hour Shaft Alternative Zero Clearance to Combustibles Telescoping Wrap Technique With Banding For Ducts 24 inches (60,9 cm) or Less System integrity is limited by quality of installation. Page 6 1. One Layer 3M Fire Barrier Duct Wrap 15A 2. Steel Banding 1/2 in. (13 mm) Wide Min. Typical 3. 3 in. (76 mm) Min. Longitudinal Overlap 4. 3 in. (76 mm) Min. Perimeter Overlap 5. 6 in. (152 mm) Wide Collar Made From 3M Fire Barrier Duct Wrap 15A Alternate Collar: Prefabricated 3M Fire Barrier 20A Collar 6. Firmly Butted Joint • 3" (76 mm) 1-1/2" (38 mm) 3" (76 mm) 1 -1/2" (38 mm System integrity is limited by quality of installation. Figure 1B Telescoping Overlap Wrap Option Cross Sectional View 21" (53,3 cm) Typ. Figure 1C Checkerboard Overlap Wrap Option Cross Sectional View Figure 1D Butt Joint With Collar Option Cross Sectional View 6" (152 mm 3" (76 mm 1-1/2" (38 mm 0 3" (76 mm) 1-1/2" (38 mm) 3" (76 mm) 1/2" (38 mm) 1/2" (38 mm) Page 7 1. One Layer 3M Fire Barrier Duct Wrap 15A 2. 1 -1/2 in. Square (38 mm) or 1 -1/2 Dia. (38 mm) Galvanized Speed Clips 3. 3 in. (76 mm) Min. Longitudinal Overlap 4. 3 in. (76 mm) Min. Perimeter Overlap Page 8 Figure 2A 3M Fire Barrier Duct Wrap 15A Commercial Kitchen Grease Duct Systems 1 or 2 Hour Shaft Alternative Zero Clearance to Combustibles Telescoping Wrap Technique With Weld Pins Only System integrity is limited by quality of installation. 1. One Layer 3M Fire Barrier Duct Wrap 15A 2. 1 -1/2 in. Square (38 mm) or 1 -1/2 Dia. (38 mm) Galvanized Speed Clips 3. 3 in. (76 mm) Min. Longitudinal Overlap 4. 3 in. (76 mm) Min. Perimeter Overlap 5. 6 in. (152 mm) Wide Collar Made From 3M Fire Barrier Duct Wrap 15A Alternate Collar: Prefabricated 3M Fire Barrier 20A Collar 6. Firmly Butted Joint 3" (76 mm) 1-1/2" (38 mm) 3" (76 mm 1-1/2" (38 mm 0 System integrity is limited by quality of installation. Figure 2B Telescoping Overlap Wrap Option Cross Sectional View 21" (53,3 cm) Typ. Figure 2C Checkerboard Overlap Wrap Option Cross Sectional View Figure 2D Butt Joint With Collar Option Cross Sectional View 3" (76 mm) 1-1/2" (38 mm 21" (53,3 cm) Typ. 6" (152 mm) 3" (76 mm) 1-1/2" (38 mm) 3" (76 mm) 1 -1 /2" (38 mm) Page 9 1. Access Hole 2. 1/4 in. (6 mm) Dia. All Threaded Rods 3. Access Cover — 16 Gauge 4. Insulation Pins — Welded 5. First Layer 3M Fire Barrier Duct Wrap 15A Cut Same Size As Cover 6. Second Layer 3M Fire Barrier Duct Wrap 15A with 1 in. (25mm) Overlap On All Sides 7. Speed Clips 8. Aluminum Tape Covering All Exposed Edges 9. Spool Pieces For Threaded Rods 10. 1/4 in. (6mm) Diameter Wing Nuts System integrity is limited by quality of installation. Page 10 Figure 3 3M Fire Barrier Duct Wrap 15A Commercial Kitchen Grease Duct Systems 1 or 2 Hour Access Door System 1. Floor /Ceiling or Wall Assembly 2. Duct 3A. One Layer 3M Fire Barrier Duct Wrap 15A 3B Banding or Pinning 3C. Packing Material 3D. 3M Fire Barrier 1000 N /S, 1003 S/L or 2000+ Silicone Sealant For Wall Assembly Apply Sealant To Both Sides of Wall • System integrity is limited by quality of installation. Figure 4A 3M Fire Barrier Duct Wrap 15A Commercial Kitchen Grease Duct Systems 1 or 2 Hour Through Penetration Systems 4 -1/2 inch (11,4 cm) Concrete Floor or Wall 91 Omega Point Laboratories, Inc. Through Penetration Systems FS 560 F FS 562 W FS 578 F FS 579 W • 76 mm) 76 mm) Page 11 1A. Studs 1 B. Gypsum Wallboard 2. Duct 3A. One Layer 3M Fire Barrier Duct Wrap 15A 3B. Banding or Pinning 3C. Packing Material 3D. 3M Fire Barrier 1000 N/S or 2000+ Silicone Sealant Figure 4B 3M Fire Barrier Duct Wrap 15A Commercial Kitchen Grease Duct Systems 1 or 2 Hour Through Penetration Systems Fire -Rated Gypsum Wallboard System integrity is limited by quality of installation. Page 12 3" (76 mm (76 mm) Omega Point Laboratories, Inc. Through Penetration Systems FS 557 W FS 559 W 1. Floor /Ceiling or Wall Assembly 2. Duct 3A. One Layer 3M Fire Barrier Duct Wrap 15A — Terminated on Each Side of Floor or Wall Penetration. 3B Banding or Pinning 3C. Packing Material 3D. 3M Fire Barrier 1000 N /S, 1003 S/L or 2000+ Silicone Sealant For Wall Assembly Apply Sealant To Both Sides of Wall a • a System integrity is limited by quality of installation: Figure 4C 3M Fire Barrier Duct Wrap 15A Commercial Kitchen Grease Duct Systems 1 or 2 Hour Through Penetration Systems 4 -1/2 inch (11 cm) Concrete Floor or Wall /3" r r r Omega Point Laboratories, Inc. Through Penetration Systems FS 561 F FS 563 W FS 578 F FS 579 W (76 mm) " (76 mm) Page 13 1. Fire -rated Floor /Ceiling Assembly 2. Duct 3A. One Layer 3M Fire Barrier Duct Wrap 15A 3B Banding or Pinning 3C. Packing Material 3D. 3M Fire Barrier 1000 N /S, 1003 S/L or 2000+ Silicone Sealant Figure 4D 3M Fire Barrier Duct Wrap 15A Commercial Kitchen Grease Duct Systems 1 Hour Through Penetration Systems Fire -Rated Wood /Gypsum - Floor /Ceiling Assembly System integrity is limited by quality of installation. Page 14 Omega Point Laboratories, Inc. Through Penetration Systems FS 558 F 1. Concrete Slab 2. One Layer 3M Fire Barrier Duct Wrap 15A 3. Concrete Fasteners = Minimum 1/4 in. (6 mm) Dia. Steel Concrete Anchors 4. 1/8 in. (3mm) Thick x 2 in. -3in. (50mm - 76mm) Wide Bar Stock Perforated 12 in. (30 cm) O.C. 5. Duct 6. Banding 7. Banding Clips 3 " 76 Figure 5 3M Fire Barrier Duct Wrap 15A Commercial Kitchen Grease Duct Systems Suggested 1 or 2 Hour Three Sided Wrap A System integrity is limited by quality of installation- D Page 15 1. Concrete Slab 2. One Layer 3M Fire Barrier Duct Wrap 15A 3. Concrete Fasteners - Minimum 1/4 in. (6 mm) Dia. Steel Concrete Anchors 4. 1/8 in. (3 mm) Thick x 2 in. -3 in. (50 mm — 76 mm) Wide Bar Stock Perforated 12 in. (30 cm) O.C. 5. Duct 6. Banding 7. Banding Clips 3" (76 mm) Figure 6 3M Fire Barrier Duct Wrap 15A Commercial Kitchen Grease Duct Systems Suggested 1 or 2 Two Hour Two Sided Wrap System integrity is limited by quality of installation. Page 16 W 1. Hood 2. One Layer 3M Fire Barrier Duct Wrap 15A 3. 3 in. (76 mm) Minimum Overlap 4. Banding Figure 7 3M Fire Barrier Duct Wrap 15A Commercial Kitchen Grease Duct Systems 1 or 2 Hour Shaft Alternative Zero Clearance to Combustibles Suggested Exhaust Hood System integrity is limited by quality of installation. N/` i/ Page 17 1. Duct 2. Roof Assembly 3. Roof Flashing 4. Vent Flashing 5. One Layer 3M Fire Barrier Duct Wrap 15A 6. Firestopping System for Rated Roof Assemblies Only Figure 8 3M Fire Barrier Duct Wrap 15A Commercial Kitchen Grease Duct Systems 1 or 2 Hour Shaft Alternative Zero Clearance to Combustibles Suggested Roof Vent System integrity is limited by quality of installation. Page 18 1. One Layer 3M Fire Barrier Duct Wrap 15A 2. One Layer 3M Fire Barrier Duct Wrap 15A Overlapped At Base 3. Mechanical Fasteners and Washers 4. Duct 5. Rated Floor /Ceiling 6. Firestopping System 7. Banding 8. Support Channel Figure 9 3M Fire Barrier Duct Wrap 15A Commercial Kitchen Grease Duct Systems 1 or 2 Hour Shaft Alternative Zero Clearance to Combustibles Suggested Vertical Support 3" (76 mm) MIN. TYP. System integrity is limited by quality of installation. Page 19 Warranty and Limited Remedy. This product will be free from defects in material and manufacture for a period of ninety (90) days from date of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OR MERCHANTIBILITY OR FITNESS FOR A PARTICULAR PURPOSE. User is responsible for determining whether the 3M product is fit for a particular purpose and suitable for user's method of application. If this 3M product is proved to be defective within the warranty period stated above, your exclusive remedy and 3M's sole obligation shall be, at 3M's option, to replace or repair the 3M product or refund the purchase price of the product. Limitation of Liability. Except where prohibited by law, 3M will not be liable for any loss or damages arising from the use of this 3M product, whether direct, indirect, special, incidental or consequential, regardless of the legal theory asserted, including warranty, contract, negligence or strict liability. Building Safety Solutions Department 3M Center 223 -2S -24 St. Paul, MN 55144 -1000 Phone 800 - 328 -1687 Fax 888 - 362 -2737 www.3m.com/firestop Printed in U.S.A. Bolger 6080546 Co 3M 2006 98- 0400 - 5054 -8 (Aug. 2006) • ACTIVITY NUMBER: M08 -271 PROJECT NAME: PITA PIT SITE ADDRESS: 381 STRANDER BL X Original Plan Submittal Response to Correction Letter # DATE: 11 -12 -08 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: 1' �•1 L I C d in "i vision Complete Comments: Please Route Documents/routing slip.doc 2 -28 -02 �ERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP Public Works ❑ Structural 511 VWC , lI Fire Prevention DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11 -13-08 Incomplete Permit Ceiiter•:Use Only: INCOMPLETE LETTER MAILED: LETTER OF COMPLETENE MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Structural Review Required APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Planning Division ❑ Permit Coordinator Not Applicable ❑ No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE: 12-11-08 n Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: PermittCenter4gse-Oriiy �• CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 CBIC SC8314 10/30/2001 Until Cancelled $6,000.00 06/27/2001 1 CBIC 5C8314 10130/2000 10/30/2001 $4,000.00 /26/2007 Name Role Effective Date Expiration Date BROWN, GREGORY J OWNER 10/31/2000 Amount Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 6 LIBERTY NORTHWEST INS CORP BL053418428 10/30/200810/30 /2009 $1,000,000.0009 /23/2008 5 OHIO CAS INS CO BLO53418428 10/30/200510/30 /2008 $1,000,000.0009 /26/2007 Untitled Page General /Specialty Contractor A business registered as a construction contractor with Latl to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company PLATEAU MECHANICAL 3608024396 PO BOX 143 ENUMCLAW WA 98022 KING INDIVIDUAL UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 602075248 ACTIVE PLATEM *008PU CONSTRUCTION CONTRACTOR 10/31/2000 10/30/2010 HTG /VENT /AIR CONDITIONING UNUSED Business Owner Information Bond Information Insurance Information • Page 1 of 2 https: // fortress. wa. gov /lni/bbip/Detail. aspx ?License = PLATEM * 008PU 11/26/2008 Nv wa z EKb p w w I0Lw TC� duo! !@ E pN0'6 z w w zz a Wa G 2 z OFIZ n} x zw o t C kzhe z azIF �a z d� W ii ?, W6.0 z n w z a0 z.�zn • zzoa • w 14Wa K wo O g 4 1 6 pp bay® 0 0 T !z < C ✓ ▪ ?o 0 U F-Yl 0 Z g0o Wwt W o� W zoa W az� - 03 * • Z W - W 0 po 0 OPAR C is 1 0g°0 0 N U 0LO P Ca -U • r W� w( o� w o I�hO� W a d W Ct p 44 4( 3 ) U� wviK QFWIL Coo 0rz Z /p -§ Z 3 944 o z W 0 � U�h�► I ° zw D r y# 0 - 0 W T z FW�j a nF TYPE HOOD VENTLATOON SYSTEM] SEQUENCE OF OPERATION f-4vAc SEN RAL NOTES THE SUB - CONTRACTOR SHALL VISIT THE JOB SITE AND BECOME FAMILIARIZED WITH ALL REQUIREMENTS OF THE CONTRACT PRIOR TO SUBMISSION OF BID. THE SUB - CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER OF ANY CONFLICTS PRIOR TO BID OR START OF INSTALLATION. THE SUB- GONTRRGTOR SHALL ARRANGE FOR ALL INSPECTIONS WHEN THEY BEGOME DUE, AND SHALL NOT COVER ANY WORK UNTIL APPROVED BY THE INSPECTION AUTHORITY. ANY AND ALL FEES ASSOCIATED WITH THE MECHANICAL WORK, INCLUDING CONSTRUCTION AND INSPECTIONS SHALL BE PAID FOR BY THE SUB - CONTRACTOR IN ORDER TO DELIVER A COMPLETE AND FINISHED BUILDING, READY FOR OCCUPANCY AND 100% USAGE. THE SUBMISSION OF A PROPOSAL WILL 13E CONSTRUED AS EVIDENCE THAT THE SUB - CONTRACTOR HAS FAMILIARIZED HIMSELF /HERSELF WITH THE PLANS AND BUILDING SITE. CLAIMS MADE SUBSEQUENT TO THE PROPOSAL FOR MATERIALS AND LABOR BECAUSE OF DIFFICULTIES ENGOUNTERED, WILL NOT BE RECOGNIZED IF THEY COULD HAVE BEEN FORESEEN HAD PROPER EXAMINATION BEEN MADE. ANY COSTS DUE TO THE LACK OF COOPERATION AMONG TRADES SHALL BE BORNE BY THE SUB - CONTRACTOR. THE INFORMATION PRESENTED ON THESE DRAWINGS IS DIAGRAMMATIC IN NATURE. IT DOES NOT NECESSARILY REPRESENT ALL FITTINGS, HANGERS, ETC. FOR A COMPLETE WORKING SYSTEM. PROVIDE ALL MATERIALS AND LABOR FOR COMPLETELY FINISHED AND OPERATIONAL SYSTEMS. REFER TO LATEST ARCHITECTURAL DRAWINGS FOR EXACT WALL LOCATIONS, DIMENSIONS, AND PLUMBING FIXTURE LOCATIONS AND REQUIREMENTS. SUB - CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY ALTERATIONS REQUIRED BY THE OWNER, ARCHITECT, OR FIELD CONDITIONS. ALL EQUIPMENT SHALL BE NEW, SHALL COMPLY WITH APPLICABLE INDUSTRY STANDARDS, WITH SPEGIFIGATIONS ON DRAWINGS, AND ENERGY CODE COMPLIANCE CERTIFICATION AS ADOPTED BY THE STATE, AS WELL AS LOGAL JURISDICTIONAL BUILDING DEPARTMENT. SUBMIT DATA FOR APPROVAL PRIOR TO ORDERING EQUIPMENT. SUBMITTAL SHALL INCLUDE ENERGY CODE COMPLIANCE CERTIFICATION. SUB - CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR ALL EQUIP- MENT INCLUDING: FIXTURES SPECIFIED IN EQUIPMENT SCHEDULE ON DRAWINGS FOR REVIEW/APPROVAL (5) PAYS PRIOR TO BID. EQUIPMENT IS NOT TO BE ORDERED 1NI THOUT SUBMITTAL TO ARCHITECT/OWNER/ENGINEER. ALL SPACE HEATING SUPPLY AIR DUGTS SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH THE LATEST S.M.A.C.N.A. DUCT CONSTRUCTION STANDARDS AND BE INSULATED IN ACCORDANCE WITH APPLICABLE STATE AND LOCAL JURISDICTIONAL ENERGY CONSER- VATION STANDARDS AND THE LATEST EDITION INTERNATIONAL MECHANICAL CODE. ALL DUCT DIMENSIONS ARE CLEAR INSIDE DIMENSIONS. INCREASE LISTED DUCT SIZE TO ACCOMMODATE LINER. FLEX SHALL NOT EXCEED & FT. IN LENGTH AMP SHALL BE TYPE "I" FACTORY DUCT. PROVIDE WITH I IN. EXTERNAL INSULATION IF MAIN SUPPLY DUCT IS INSULATED. ALL SUPPLY RUN -OUTS TO HAVE MANUALLY ADJUSTABLE VOLUME DAMPERS WITH ABILITY TO LOCK IN PLAGE. THIS SUB- GONTRAGTOR SHALL INCLUDE IN HIS/HER BID THE COMPLETE COST FOR THE ELECTRICAL CONTRACTOR TO INTERLOCK EXHAUST FANS AS REQUIRED BY EQUIPMENT SCHEDULE. THIS SUB- GONTRAGTOR SHALL FIELD VERIFY 10 FT. MINIMUM CLEARANCE BETWEEN FRESH AIR INTAKE AND ALL VENTS OR EXHAUST OUTLETS. HALL THERMOSTATS FOR HEATING /COOLING UNITS TO BE AUTOMATIC CHANGEOVER TYPE AMP INSTALLED 4& IN. ABOVE FINISHED FLOOR. EXHAUST DUCTS THROUGH ROOF SHALL TERMINATE 12 IN. ABOVE ROOF DECK WITH APPROVED ROOF GAP. ALL ROOFTOP UNITS SUPPLYING MORE THAN 8000 CFM OF AIR SHALL BE EQUIPPED WITH A SMOKE DETECTOR IN THE MAIN RETURN AIR DUCT WHICH WILL SHUT THE POWER OFF TO THE UNIT WHEN SMOKE IS DETECTED, THIS SMOKE DETECTOR SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR AND WIRED BY THE MECHANICAL CONTRACTOR. IN BUILDINGS WHERE FIRE DETECTION OR ALARM SYSTEMS ARE PROVIDED, THE SMOKE DETECTOR SHALL BE WIRED BY THE ELECTRICAL CONTRACTOR AND SHALL BE SUPERVISED BY FIRE ALARM SYSTEM, SEE LATEST EDITI ❑N UNIFORM MECHANICAL CODE SECTION 608 FOR ADDITIONAL REQUIREMENTS, MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL REMOTE TEST SWITCH AND INDICATING LIGHT AT CEILING LOCATION BELOW ROOFTOP UNIT LOCATION. NORMAL OPERATING MODE THE MUA /HOOD EXH. FAN ASSEMBLY SHALL BE CONTROLLED BY A REMOTE CONTROL CONSOLE AS LISTED IN THE MUA UNIT EQUIPMENT SCHEDULE, THE CONSOLE SHALL BE MOUNTED ON THE OUTSIDE OF THE HOOD AND PROVIDE THE OPERATOR WITH THE FOLLOWING CONTROL OPTIONS! °BLOWER FAN - ON OR OFF °HEAT - ON OR OFF °COOLING (EVAP COOLER) - ON OR OFF °ADDITIONALLY, A ROOM THERMOSTAT SHALL CONTROL THE GAS VALVE IN THE MUA UNIT TO PROVIDE AN OVERRIDE OPTION FOR HEATING. THE HOOD EXHAUST FAN SHALL BE INTERLOCKED TO OPERATE WHEN THE MUA UNIT IS OPERATING. FIRE MODE IF THE FIRE DETECTION SYSTEM INDICATES THERE IS A FIRE, THE GAS -LINE SOLENOID SHALL SHUT OFF, THE HOOD EXHAUST SHALL OPERATE, AND THE MUA UNIT SHALL BE SHUT OFF, COORDINATION INSTALLATION IN ACCORDANCE WITH LATEST EDITION N,F,P,A, 96 AND COORDINATED WITH HOOD FIRE PROTECTION CONTRACTOR. MATERIAL COORDINATION SCHEDULE THE FOLLOWING ELECTRICAL COMPONENTS SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR. oMUA UNIT /HOOD EXHAUST FAN STARTERS AND DISCONNECTS oMUA/HOOD EXHAUST FAN REMOTE CONTROL CONSOLE °HEATING UNIT REMOTE CONTROL THERMOSTAT oGAS LINE SOLENOID SHUT -OFF VALVE oEVAP COOLER CONTROLS, FREEZESTAT, DRAIN AND FILL KIT °ELECTRICAL CONTRACTOR WILL INSTALL AND CONNECT STARTERS AND DISCONNECT SWITCHES, AND WILL INSTALL CONDUIT FOR CONTROL • WIRING. MECHAN I GAL L C ENE2 M- ) SUPPLY DIFFUSER - SEE SCHEDULE ON DRAWINGS. RETURN AIR GRILLE - SEE SCHEDULE ON DRAWINGS. EXISTING RETURN AIR GRILLE 0 THERMOSTAT SHALL HAVE LOCKING COVER IN ALL PUBLIC AREAS. MOUNT OUT OF DIRECT SUN, PROVIDE I IN. RIGID INSULATION BEHIND SHEET ROCK WHERE BACKED UP TO UNHEATED OR EXTERIOR HALLS. MANUAL BALANCING DAMPER - PROVIDE WHERE SHOWN, AT ALL RUN -OUTS TO AIR OUTLETS, AND AT ALL MAIN DUCT SPLITS. DAMPERS SHALL BE 'YQUN6 REGULATOR GO" MODEL &20 OR. EQUAL. INTERNAL ACOUSTIC LINING IN DUCTWORK WHERE NOTED ON DRAWINGS OR SPECIFICATIONS. PROVIDE INSULATION FOR ALL SUPPLY DUCTS FROM POINT OF CONNECTION AT UNIT TO ALL AIR OUTLETS. ALL DUCT DIMENSIONS ARE CLEAR INSIDE. FLEX SUPPLY SHALL BE FACTORY FABRICATED, GLASS I, VAPOR BARRIER, COMPLYING WITH N.F.P.A. QOA AND U.L. I &I. MAXIMUM & FT. LONG. PROVIDE TURNING VANES AT ALL CORNER BENDS IN ACCORDANCE WITH S.M.A.C.N.A. LOW VELOCITY DUCT MANUAL. TYPICAL DUCT TAKE -OFF WITH MANUAL VOLUME DAMPER. MARK DAMPER POSITION AFTER AIR BALANCE. EXISTING SUPPLY DIFFUSER MOTORIZED DAMPER HVAG TEST I NO AND ALAN° I NS RE.GU I REMENTS THE MECHANICAL CONTRACTOR SHALL EMPLOY THE SERVICES OF AN INDEPENDENT TEST AND BALANCE CONTRACTOR TO BALANCE THE HVAG SYSTEMS IN ACCORDANCE WITH THE DRAWINGS. HVAG SYSTEMS SHALL BE BALANCED IN ACCORDANCE WITH THE LATEST NEBB PROCEDURAL STANDARDS. THE BALANCING CONTRACTOR SHALL HAVE AT LEAST (3) THREE YEARS OF EXPERIENCE IN TESTING AND BALANCING. THE BALANCING REPORT SHALL CONTAIN ALL INFORMATION REQUIRED BY NESS PROCEDURAL STANDARDS FOR TESTING, ADJUSTING, AND BALANGINS. THE REPORT SHALL INCLUDE, BUT MAY NOT BE LIMITED TO THE FOLLOWING: A COMPLETE LIST OF BALANCING INSTRUMENTS AND THEIR LATEST CALIBRATION DATES 15 TO BE INCLUDED IN THE FINAL REPORT. BLOWER: MOTOR HP, VOLTAGE, AMPERAGE (NAMEPLATE AND ACTUAL) RPM, BELT MAKE/MODEL, SHEAVE MAKE/MODEL. UNIT: MAKE/MODEL/SERIAL NUMBER, FILTER TYPE/SIZE/QUANTITY, FINAL BALANCED DAMPER POSITIONS. AIR INLETS AND OUTLETS: DESIGN/PRELIMINARY/FINAL GFM'S (EXCLUDES RETURN GRILLES). ALL MANUAL SINGLE BLADE DAMPERS SHALL BE SECURED IN THEIR FINAL BALANCED POSITIONS WITH A SHEET METAL SCREW THRU THE DAMPER HANDLE. ALL COMPONENTS SHALL BE BALANGED TO WITHIN +/- 10% OF DESIGN GEM REQUIREMENTS. KITCHEN GREASE HOODS! A SHORTRIDGE VELGRID (OR SIMILAR DEVICE CAPABLE OF AVERAGING VELOCITIES AT SEVERAL POINTS SIMULTANEOUSLY), SHALL BE UTILIZED TO MEASURE VELOCITY AT THE FACE OF THE HOOD. A GRID DIAGRAM OF THE HOOD FACE, NOTING VELOCITIES AT ALL SECTIONS SHALL BE INCLUDED IN THE BALANCE REPORT. 506.3.12.1 Termination above the roof. Exhaust outlets that terminate above the roof shall have the discharge opening located not less than 40 inches (1016 mm) above the roof surface. PROVIDE FIRE RESISTANT DUCT WRAP AT THE TYPE I HOOD DUCTS TO PROVIDE A MINIMUM I HOUR RATING. DUCT WRAP TO COMPLY WITH Ant NFPA I LOCAL CODES. PROVIDE PRODUCT SUCH Ae 3M OR EQUAL. Is' MN. FROM UNPROTECTED COMBUSTABLES. PRMECTED COM5USTABLES. SPECIAL INSPECTIONS FOR TYPE I HOOD & DUCT (RE: IBC 1704.13 Special Cases) Type I hood and ducts shall be inspected by a special inspection agency. Grease duct and grease hootl test shall comply with 2006 IMC 506.3.3.1 Grease Duct Test per Washington State Amendments, and IMC 507.7.1 Hood joints, seams and penetrations for Type I hoods. 2006 IMC 507.2.1.1 OPERATION. Type I Hood systems shall be designed and installed to automatically activate the exhaust fan whenever cooking operations occur. The activation of the exhaust fan shall occur through an interlock with the cooking appliance, by means of heat sensors or by means of other approved methods. 508.1 MAKEUP AIR. For mechanical makeup air systems, the exhaust and makeup air systems shall be electrically interlocked to insure that makeup air is provided when ever the exhaust system is in operation. Makeup air intake opening locations shall comply with Sections 401.4 and 401.4.1. \COMPENSATING HOOD EP-Is HINGED ACCESS VENTED ROOF CURB 6' MIN 10 Ft. MIN. HOOD t2 TAIL GREASE DUCT TO 13E FAI3RICATED IS GA. MSG STEEL OR 18 Ga. MSG STAINLESS STEEL WITH CONTINUOUS .1ELDED SEAMS. CEILING FLASH SOLID AT CEILNC AND WALLL IF LESS THAN 12'. 48' MAX FLOOR SF -1 KCV1tbvtu rUK CODE COMPLIANCE APPROVED City Of Tukwila ItDING DIVISION NOV 2 0 201 13 MECHANICAL M ENGiINEERS w EL.ECTRICAL 6909 South Holly Circle, Suite 304 EriGliewe,001, Cn1c Goal® e0112 Ph! (303) 773 -8773 Fax: (303) 779 -8333 REVISIONS WILL HARRIS ARCHITECTS 2151 E. Beaver Lake Dr. SE Sammamish, WA 98075 Ph: (425) 391-2321 Fax (425) 391 -2750 BY u RECEIVED w NOV 12 2008 PERMIT CENTEF DATE 08/06/08 SCALE DRAWN JoB 0812AC SHEET AS NOTED 2 OF 2 SHEETS OUTSIDE AIR REQUIREMENT SCHEDULE LOCATION SPACE CFM REQ'D TOTAL CFM REQUIRED KITCHEN 4 PEOPLE 20 /PERSON 80 DINING 20 PEOPLE 20 /PERSON 400 480 TOTALS AIR BALANCE SCHEDULE UNIT SUPPLY AIR FLOW (CFM) RETURN AIR FLOW (CFM) 1600 OUTSIDE AIR FLOW (CFM) ISI• EXHAUST AIR FLOW (CFM) BUILDING PRESSURE (CFM) RTU 2000 • +400 SF -1 800 0 800 0 +810 EF -1 0 0 0 900 —900 EF -2 0 0 0 75 -75 TOTALS RESULTING BUILDING PRESSURIZATION: +225 CFM q` E0OW W mow- WW7Z PZC OUO- z COO zE W zz WIZ" a2z Oiz gEq 0} I ZW rite, W Z UZ S< �8 a olio Ile zF' z Z z o6 W � Qa o ©WJa ci a z a mo O WWZNN 8 Z U 3QC; N W h3 } jw0 41a a w isig QOp U 0 U z L C o Iu Z tN U ] Z0 0 D. Z W z0 .- 0 W °w z_ � pL D Z }}q WW Y.W - LdQz Z W Lz e 1 F0 0Q3 I a h 0000 � W WAS W � y0 p,. YJ a Z 00W U� IppI����11 a � U oQaa g WWC o�=d Co 0 z�oW p ? m 0 0 W � af 17H -I arw �EI1M1I� 24/8 PN IO "4) 10 "4) I4 "4 GP -I 300 GFM RC -1 24X1 12 "4) 4 2/12 16/16 PUGT UP TO RTU G[7 -1 350 GFM RTU -1 — ROOFTOP UNIT EXISTING 5 TON RTU. 100 MBH HEATING 2000 CFM 10 "4' 10 "i4' M EQUIPMENT SP-I 350 GFM SD-1 350 GFM EF - 2 -- EXHAUST FAN GREENHECK MODEL SP —B90 DIRECT DRIVE, TOILET EXHAUST FAN, 75 CFM @ 0,250' SR 50 WATT MOTOR, 120/1/60, INTERLOCK WITH LIGHT SWITCH. PROVIDE WI ROOF DISCHARGE CAP SF -1 — SUPPLY FAN CAPTIAVE AIR SUPPLY FAN MODEL SFB90 -0HD, 810 CFM @ 0,70' SR BOTTOM DISCHARGE, 1/3 HP MOTOR, 120V/1/60, EF -1 — EXHAUST FAN CAPTIVE AIRE MODEL DU5OHFA, BELT DRIVE, UPBLAST KITCHEN HOOD FAN, 960 CFM @ 1' SP, 1/2 HP MOTOR, 6,3 FLA, 120V /1/60, PROVIDE W/ VENTED ROOF CURB. DH -1 -- DUCT HEATER INLINE MARKEL HF SERIES OPEN C ❑IL ELEMENT DUCT HEATER 8 KW 208V, 1PH, 12 "4' EF -I (ON ROOF) q00 GFM SF -I (ON ROOF) &,O GFM CD-1 - CEILING DIFFUSER TITUS MODEL TMS LOUVERED FACE DIFFUSER, FRAME TYPE 1, WHITE, 24x24 FACE, CFM AND NECK SIZE AS NOTED ON DRAWING; PROVIDE BALANCE DAMPER, CD -2 — CEILING DIFFUSER TITUS MODEL TMS LOUVERED FACE DIFFUSER, FRAME TYPE 3, GYP. BRD, CLG, 6' ROUND NECK, WHITE, 12x12 FACE, CFM AS NOTED ON DRAWING, WITH BALANCE DAMPER, RG -1 — RETURN AIR GRILLE TITUS MODEL 50F EGGCRATE GRILLE, FRAME TYPE 1. WHITE, 24x14 FACE, 1/2x1/2 ALUMINUM GRILLE. TG-1 — TRANSFER GRILLE TITUS MODEL 301RL LOUVERED FACE GRILLE, FRAME TYPE 1, WHITE, 14x24 FACE. SD -1 — SUPPLY DIFFUSER TITUS MODEL TMRA ROUND LOUVERED FACE DIFFUSER, FRAME TYPE 1. 10' ROUND NECK, WHITE, 20' DIA, FACE, CFM AS NOTED ON DRAWING. WITH' BALANCE DAMPER, HOOD - HOOD -1 -- TYPE I CAPTIVE AIRE MODEL 4824ND- 2 —PSP — F 48'x48' W/ PERE, SUPPLY PLENUM. q/q DUGT UP TO EF -I SCALE: 1/2 HAS I GAL = I t 5P-1 300 GFM ALA 2f 4 RETURN GTUPTORTU 6 "4) UP THRU ROOF TERMINATE Hi ROOF GAP Q - GO-2 15 GFM EF -2 c15 GFM O a KtV1 y1/I:U r it CODE COMPLIANCE APPROVED GD -I 215 GFM NOV 2 0 2008 City Of Tukwila BUILDIN ; DIVISION MO& 211 P WWI? 016001116iMiliiillailelp oG�1C MECHANICAL M ENGINEERS M ELECTRICAL 6909 South Holly Circle, Suite 304 Englewood, Cc:lor0 do 80112 Phi (303) 773 -6773 Fox; 6303) 7798333 SCALE DRAWN <I[ > 0 -z ill NI, 0 1 0 .66 H RECEIVEL u NOV 12 ZO08 w o PEWIT CENTER Q.. DATE 08/06/08 AS NOTED J05 0812AG SHEET OM OP 2 SHEETS REVISIONS BY WILL HARRIS ARCHITECTS 2151 E. Beaver Lake Dr. SE Sammamish, WA 98075 Ph: (425) 391 -2321 Fax (425) 391 -2750 q` E0OW W mow- WW7Z PZC OUO- z COO zE W zz WIZ" a2z Oiz gEq 0} I ZW rite, W Z UZ S< �8 a olio Ile zF' z Z z o6 W � Qa o ©WJa ci a z a mo O WWZNN 8 Z U 3QC; N W h3 } jw0 41a a w isig QOp U 0 U z L C o Iu Z tN U ] Z0 0 D. Z W z0 .- 0 W °w z_ � pL D Z }}q WW Y.W - LdQz Z W Lz e 1 F0 0Q3 I a h 0000 � W WAS W � y0 p,. YJ a Z 00W U� IppI����11 a � U oQaa g WWC o�=d Co 0 z�oW p ? m 0 0 W � af 17H -I arw �EI1M1I� 24/8 PN IO "4) 10 "4) I4 "4 GP -I 300 GFM RC -1 24X1 12 "4) 4 2/12 16/16 PUGT UP TO RTU G[7 -1 350 GFM RTU -1 — ROOFTOP UNIT EXISTING 5 TON RTU. 100 MBH HEATING 2000 CFM 10 "4' 10 "i4' M EQUIPMENT SP-I 350 GFM SD-1 350 GFM EF - 2 -- EXHAUST FAN GREENHECK MODEL SP —B90 DIRECT DRIVE, TOILET EXHAUST FAN, 75 CFM @ 0,250' SR 50 WATT MOTOR, 120/1/60, INTERLOCK WITH LIGHT SWITCH. PROVIDE WI ROOF DISCHARGE CAP SF -1 — SUPPLY FAN CAPTIAVE AIR SUPPLY FAN MODEL SFB90 -0HD, 810 CFM @ 0,70' SR BOTTOM DISCHARGE, 1/3 HP MOTOR, 120V/1/60, EF -1 — EXHAUST FAN CAPTIVE AIRE MODEL DU5OHFA, BELT DRIVE, UPBLAST KITCHEN HOOD FAN, 960 CFM @ 1' SP, 1/2 HP MOTOR, 6,3 FLA, 120V /1/60, PROVIDE W/ VENTED ROOF CURB. DH -1 -- DUCT HEATER INLINE MARKEL HF SERIES OPEN C ❑IL ELEMENT DUCT HEATER 8 KW 208V, 1PH, 12 "4' EF -I (ON ROOF) q00 GFM SF -I (ON ROOF) &,O GFM CD-1 - CEILING DIFFUSER TITUS MODEL TMS LOUVERED FACE DIFFUSER, FRAME TYPE 1, WHITE, 24x24 FACE, CFM AND NECK SIZE AS NOTED ON DRAWING; PROVIDE BALANCE DAMPER, CD -2 — CEILING DIFFUSER TITUS MODEL TMS LOUVERED FACE DIFFUSER, FRAME TYPE 3, GYP. BRD, CLG, 6' ROUND NECK, WHITE, 12x12 FACE, CFM AS NOTED ON DRAWING, WITH BALANCE DAMPER, RG -1 — RETURN AIR GRILLE TITUS MODEL 50F EGGCRATE GRILLE, FRAME TYPE 1. WHITE, 24x14 FACE, 1/2x1/2 ALUMINUM GRILLE. TG-1 — TRANSFER GRILLE TITUS MODEL 301RL LOUVERED FACE GRILLE, FRAME TYPE 1, WHITE, 14x24 FACE. SD -1 — SUPPLY DIFFUSER TITUS MODEL TMRA ROUND LOUVERED FACE DIFFUSER, FRAME TYPE 1. 10' ROUND NECK, WHITE, 20' DIA, FACE, CFM AS NOTED ON DRAWING. WITH' BALANCE DAMPER, HOOD - HOOD -1 -- TYPE I CAPTIVE AIRE MODEL 4824ND- 2 —PSP — F 48'x48' W/ PERE, SUPPLY PLENUM. q/q DUGT UP TO EF -I SCALE: 1/2 HAS I GAL = I t 5P-1 300 GFM ALA 2f 4 RETURN GTUPTORTU 6 "4) UP THRU ROOF TERMINATE Hi ROOF GAP Q - GO-2 15 GFM EF -2 c15 GFM O a KtV1 y1/I:U r it CODE COMPLIANCE APPROVED GD -I 215 GFM NOV 2 0 2008 City Of Tukwila BUILDIN ; DIVISION MO& 211 P WWI? 016001116iMiliiillailelp oG�1C MECHANICAL M ENGINEERS M ELECTRICAL 6909 South Holly Circle, Suite 304 Englewood, Cc:lor0 do 80112 Phi (303) 773 -6773 Fox; 6303) 7798333 SCALE DRAWN <I[ > 0 -z ill NI, 0 1 0 .66 H RECEIVEL u NOV 12 ZO08 w o PEWIT CENTER Q.. DATE 08/06/08 AS NOTED J05 0812AG SHEET OM OP 2 SHEETS