Loading...
HomeMy WebLinkAboutPermit M08-272 - MED DATAMED DATA 12101 TUKWILA INTERNATIONAL BL M08 -272 Parcel No.: 0923049031 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: 12101 TUKWILA INTERNATIONAL BL TUKW MED DATA 12101 TUKWILA INTERNATIONAL BL SUITE 300 , TUKWILA WA INTERNATIONAL GATEWAY WEST 12201 TUKWILA INTERNATIONAL BLVD , SEATTLE WA Contact Person: Name: BRYAN MOORMAN Address: PO BOX 2768 , ISSAQUAH WA Citylif Tukwila Contractor: Name: METRO AIR INC Address: 11021 128 PL NE , KIRKLAND, WA Contractor License No: METROAI995RC Value of Mechanical: $5,000.00 Type of Fire Protection: SPRINKLERS Furnace: <100K BTU 0 >100K BTU 0 Floor Furnace 0 Suspended/Wall/Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System.... 0 Air Handling Unit <10,000 CFM 0 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 0 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial/Industrial 0 doc: IMC-10/06 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT EQUIPMENT TYPE AND OUANTITY * * continued on next page ** • Permit Number: Issue Date: Permit Expires On: Expiration Date: 12/03/2009 DESCRIPTION OF WORK: REISSUE OF EXPIRED PERMIT M08 -062. ADD 5 DIFFUSERS AND DUCTWORK FOR NEW OFFICES Phone: Phone: 206- 427 -6036 Phone: 425 889 -8224 M08 -272 11/25/2008 05/24/2009 Fees Collected: $226.13 International Mechanical Code Edition: 2006 Boiler Compressor: 0-3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 5 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment M08 -272 Printed: 11 -25 -2008 Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie The granting of this permit does not pre construction or the performance o Signature: doc: IMC -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us • Permit Number: M08 -272 Issue Date: 11/25/2008 Permit Expires On: 05/24/2009 Date: 1, t Date: ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. e to give authority to violate or cancel the provisions of any other state or local laws regulating am authorized to sign and obtain this mechanical permit. /25 S' Print Name: R t^(fi This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M08 -272 Printed: 11 -25 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Parcel No.: 0923049031 Permit Number: M08 -272 Address: 12101 TUKWILA INTERNATIONAL BL TUKW Status: ISSUED Suite No: Applied Date: 11/13/2008 Tenant: MED DATA Issue Date: 11/25/2008 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Cond -10/06 * *continued on next page ** • M08-272 Printed: 11 -25 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Date: G I AP -0g doc: Cond -10/06 M08 -272 Printed: 11 -25 -2008 Site Address: 0-,1(3 \ TT,. k.w► // rp, ' 1 t1 -LAT i° I 31 J .4 . Tenant Name: M eI D0 61 Property Owners Name: jOL (2 r ? r r eji 0v', Let& y �£(�mn�t. ( Vet. L i lh F i r Mailing Address: Name: Mailing Address: E -Mail Address: 10 r - yewk iVlwt 1 $e rVl' --3 1 14 C.. G Company Name: Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: / E T P. 4 A I 4\ 5 g. c._ Company Name: Mailing Address: Contact Person: E -Mail Address: Company Name: /Li Mailing Address: Contact Person: E -Mail Address: CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.citukwila.wa.us y a tr\ co M r 444 to r o go >` 2/ 6� M- e-iro Air I \ Q -2-- . V - FL NE. E d t'<e . 5z riY ,r' m it T i`o . 4 \1 r Q (.01- kcik`• . Act 2a3 t S A S- e /1/ -tVA r-rei atm.\ S . Y\Gx �/A, t,�Q E144"1�1 . C:41 Q:1Applications\Forms- Applications On Linel3 -2006 - Mechanical Permit Application.doc Revised: 4 -2006 bh MECHANICAL PERMIT APPLICATION Mechanical Permit No. Proje No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** King Co Assessor's Tax No.: 092- (g c A C j Suite Number: 300 Floor: IS - 1 - p\ 1�t City New Tenant: ❑ .... Yes Er.No wA state Zip Day Telephone:( 2 4 -177 - Z034, 2 55.f IAA tk L AMA qa D City State Zip Fax Number: (r(? ?) 3 (l- '' S c State Zip City Day Telephone: iC Fax Number: Expiration Date: \->- ( 3 lO c. w q City Day Telephone: ,2 cif. Fax Number: a ()- C , State Zip 941 -(43c1 City Day Telephone: Fax Number: State Zip Page 1 of 2 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood /Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator — Comm /Ind Other Mechanical Equipment S ,p Su r f l r U �`!`T l Tj Valuation of Project (contractor's bid price): $ (% oO Scope of Work (please provide detailed information): (P—d ut6 ^ jo TC v"\ 4k(- CA)., - Ari dc. c Use: Residential: New .... 0 Replacement .... Commercial: New ....El Replacement .... [ T.1-,. Fuel Type: Electric 0 Gas ....0 Other: it/ /Q, Indicate type of mechanical work being installed and the quantity below: P--)( p dl.`�Zr I Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: *0.11.)1A1 _/ (/. • Print Name: /t/ qt". Mailing Address: Pr ° *2-7 t3 Date Application Accepted: Q:\ApplicationsWorms- Applications On Line13 -2006 - Mechanical Permit Application.doc Revised: 4.2006 bh Ar Kt it City Date: t t/ II iD 2' Day Telephone: Dc6, 4;."'7 6(/ -G State Zip Date Application Expires: Staff Initials: u A Page 2 of 2 i Receipt No.: R08 -03747 Initials: WER User ID: 1655 Payee: MMI SERVICES ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www. ci. tukwila. wa. us Payment Check 2247 150.68 TRANSACTION LIST: Type Method Descriptio Amount RECEIPT Parcel No.: 0923049031 Permit Number: M08 -272 Address: 12101 TUKWILA INTERNATIONAL BL TUKW Status: PENDING Suite No: Applied Date: 11/13/2008 Applicant: MED DATA Issue Date: Account Code Current Pmts 000.322.102.00.0 105.45 000/345.830 45.23 Total: $150.68 • Payment Amount: $150.68 Payment Date: 11/13/2008 11:11 AM Balance: $0.00 doc: Receiot -06 Printed: 11 -13 -2008 COMMENTS: Type of Inspection: Address: 8101 I Date Called: J l ? 4d: A weI i Md -0Z- Requester: Phone No: 11,60 Z ,SS ) 7 ) «,f 1 2(/1f1 1 / — ,(l 14 ? - - ( (- -fAl4 1 i Project;, Type of Inspection: Address: 8101 I Date Called: Special Instructions: Date Wante 1 - 2.. f a Z )65 Requester: Phone No: 11,60 Z ,SS INSPECTION RECORD Retain a copy with permit nloa -Z7Z PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ❑ Approved per applicable codes. [] Corrections required prior to approval. Insp- to R -c - 'pt No.: Date: Z 'Date: 60 I 0 REINSPECTION FEE RE r MIRED. • rior to inspection, fee must be pai at 6300 Southcenter Blvd., 9uite 10 . Call to schedule reinspection. ACTIVITY NUMBER: M08-272 DATE: 11-13-08 PROJECT NAME: MED DATA SITE ADDRESS: 12101 TUKWILA INTERNATIONAL BL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: 11 !vision Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: Documents/routing slip.doc 2-28-02 PERMIT COOR COPY • PLAN REVIEW/ROUTING SLIP Fire Prevention Structural Permit Coordinator Incomplete Structural Review Required APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 11-18-08 Permit CetitOtiseVoiji: . • • • : `:. • • • INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: El No further Review Required DATE: DUE DATE: 12-16-08 Not Approved (attach comments) DATE: Planning Division Not Applicable ri Perm, en er... se. n • . • 12 • .-• • ; 47 P.'N C ' .? "" -7.Fl e . . • • • • 4.... 1. : 7 4171 44' it••:&• Y ? .7 • CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 CBIC 5E0682 11/15/2001 Until Cancelled $6,000.00 12/03/2001 Name Role Effective Date Expiration Date SCHEFFLER, MICHAEL A PRESIDENT 12/03/2001 Amount HANLON, ASH T VICE PRESIDENT 12/03/2001 BK00953356859 Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 7 OHIO CAS INS CO BK00953356859 11 /15/200811 /15/2009 $1,000,000.00 11 /10/2008 6 OHIO CAS INS CO BL053356859 11/15/200511/15 /2008 $1,000,000.00 10/25/2007 5 HARTFORD CAS INS 52SBAPK9831 11/15/200311/15 /2005 $1,000,000.00 10/28/2004 Untitled Page General /Specialty Contractor A business registered as a construction contractor with L£tI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company METRO AIR INC UBI No. 4258898224 Status 11021 128TH PL NE KIRKLAND WA 98033 KING CORPORATION License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 602156865 ACTIVE METROAI995RC CONSTRUCTION CONTRACTOR 12/3/2001 12/3/2009 HTG /VENT /AIR CONDITIONING UNUSED Business Owner Information Bond Information Insurance Information • https: // fortress .wa.gov /lni/bbip/Detail. aspx ?License= METROAI995RC • Page 1of2 11/25/2008 Date: Dec 04, 2007 Time: 8:38am Soak_ 1- Drawing H.. e: - )G—Lintergate WestnMedData ExpansionnWorking DrawingsMerrnit SetiviD—P0-03.dwg Xrefs: MD—T02436 IW—AB-03 1111111111111111111111111111111111111111111111111111 Is ii II 11 F I . r-1-1 jt _ 1 III mmtls 111111111111111k MP' at • • • cic x ct'qic( • 01[7:M.1411.M.11=.-71M.- - Y 4 0- ----- tr C- • • • Mau tr t I sTh -7---1 2 a Th 51 5 1. a 11•1 .1.2111111■ C3 E3 0 KEY PLAN swim wootla MeadiSt nomen ebacti S1 16TH ST INTERGATE WEST BUILDING C 12101 TUKWILA INTERNATIONAL BLVD y TUKWILA, WA 98169 �(.P VICINITY MAP PROJECT INFORMATION REVISIONS INDICATED THUS A ACT ADJ AFF ALT ALUM APPROX BLDG BLKG B/S CAB CLR CLG CL COL COMM COMP CONST CONT CPT CT DIA DIM DR DW DWG E EA ELEC ELEC'L ELEV EXIST EXT FIN FLR FLUOR FR FT FURN GA GALV GD GL GWB HC HDW HM HT HVAC IN INCL INSUL INT JT 2 � ABBREVIATIONS r ACOUSTICAL CEILING TILE ADJACENT /ADJUSTABLE ABOVE FINISH FLOOR ALTERNATE ALUMINUM APPROXIMATELY AT BUILDING BLOCKING BUILDING STANDARD CABINET CLEAR/CLEARANCE CEILING CENTERLINE COLUMN COMMUNICATION COMPOSITION CONSTRUCTION CONTINUOUS CARPET CERAMIC OR CONCRETE TILE DIAMETER DIMENSION DOOR DISHWASHER DRAWING EXISTING, EAST EACH ELECTRIC ELECTRICAL ELEVATION (VIEW) EXISTING EXTERIOR FINISH FLOOR FLUORESCENT FIRE RATED FEET FURNISH/FURNISHINGS GAUGE GALVANIZED GARBAGE DISPOSAL GLASS /GLAZING GYPSUM WALL BOARD HOLLOW CORE HARDWARE HOLLOW METAL HEIGHT HEATING, VENTILATING, AIR CONDITIONING INCH INCLUDE INSULATION INTERIOR JOINT LL @TE LF MAX MECH MFR MIN MISC MTD MTL MW N N/A NIC NO NOM NTS OC OPNG OPP ORIG PERM PL PLAM PLYWD PR PTR R RB REF REINF REQ'D REV RM RO S SCHED SC SECT SIM SPEC SQ STD STL STOR SUSP TEL TYP UNO VCT VERT W W/ W/O WC WD WSBF EXISTING B/S ACOUSTICAL CEILING TILE AND TRACK TO REMAIN. NEW B/S ACOUSTICAL CEILING TILE AND TRACK AT 7' -10" AFF. EXISTING PENDANT LIGHT FIXTURES TO REMAIN. EXISTING PENDANT LIGHT FIXTURES TO BE REMOVED. EXISTING PENDANT LIGHT FIXTURES TO BE UPGRADED FOR EMERGENCY LIGHTING, IF NEEDED. EMERGENCY LIGHTING LAYOUT IS CONCEPTUAL ONLY. ELECTRICAL CONTRACTOR TO PROVIDE EMERGENCY LIGHTING DESIGN. NEW BIS 1'x8' PENDANT LIGHT FIXTURE FOR EMERGENCY LIGHTING. EMERGENCY LIGHTING LAYOUT IS CONCEPTUAL ONLY. ELECTRICAL CONTRACTOR TO PROVIDE EMERGENCY LIGHTING DESIGN. EXISTING BIS 7x4' FLUORESCENT LIGHT FIXTURE TO REMAIN. ICJ NEW BIS 2'x4' FLUORESCENT LIGHT FIXTURE. BY LANDLORD AT TENANTS EXPENSE LINEAL FOOT MAXIMUM MECHANICAL MANUFACTURER MINIMUM MISCELLANEOUS MOUNTED D METAL MICROWAVE OVEN NORTH, NEW NOT APPLICABLE NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE ON CENTER OPENING OPPOSITE ORIGINAL PERMANENT PLATE PLASTIC LAMINATE PLYWOOD PAIR PARTITION RADIUS, REMOVE, RELOCATE RUBBER BASE REFRIGERATOR REINFORCING REQUIRED REVISION /REVERSE ROOM ROUGH OPENING SOUTH SCHEDULE SOLID CORE SECTION SIMILAR SPECIFICATION SQUARE STANDARD STEEL STORAGE SUSPENDED TELEPHONE TYPICAL UNLES NOTED OTHERWISE VINYL COMPOSITION TILE VERTICAL WEST WITH WITHOUT WALLCOVERING WOOD WASHINGTON STATE BARRIER FREE NEW B/S 2'x4' FLUORESCENT LIGHT FIXTURE FOR EMERGENCY LIGHTING. SEE EMERGENCY LIGHTING NOTE ABOVE FOR MORE INFORMATION. t� EXISTING, U.N.O., B/S EXIT SIGN. (DIRECTIONAL WHERE SHOWN). REUSE EXISTING EXIT SIGNS WHENEVER POSSIBLE. (N = NEW) KA N EXISTING, U.N.O., B/S WALL LIGHT SWITCH (N = NEW). NOTES: 1, PRIOR TO INSTALLING ANY LIGHT FIXTURES ON THIS PROJECT, THE ELECTRICAL CONTRACTOR IS TO FIELD CHECK FOR ANY CONFLICTS WITH EXISTING MECHANICAL DUCT WORK, ELECTRICAL CONDUIT, PIPES, ETC. AT EVERY LIGHT FIXTURE LOCATION AS SHOWN ON THE REFLECTED CEILING PLAN. IF A CONFLICT EXISTS, THE ELECTRICAL CONTRACTOR IS TO NOTIFY THE GENERAL CONTRACTOR. THE GENERAL CONTRACTOR IS TO NOTIFY MS&A OF THE CONFLICT(S) SO A NEW LAYOUT CAN BE GENERATED. NO LIGHT FIXTURES ARE TO BE INSTALLED UNTIL ALL CONFLICTS ARE RESOLVED. 2. CONTRACTOR SHALL PROVIDE EMERGENCY PATHWAY LIGHTING, THE MEANS OF EGRESS ILLUMINATION SHALL NOT BE LESS THAN 1 FOOT - CANDLE (11 LUX) AT THE FLOOR LEVEL. 3. CONTRACTOR SHALL VERIFY LATERAL BRACING AT EXISTING CEILING GRID & UPGRADE TO CURRENT CODES AS NECESSARY, 4, CONTRACTOR TO UPGRADE AUDIBLE AND VISUAL ALARMS TO CURRENT CODES AS NECESSARY. 5. THERE SHALL BE 42" CLEAR SPACE IN FRONT OF THE PANEL SIDE OF V.A.V. BOXES. IF LIGHTING LAYOUT CREATES A CONFLICT, NOTIFY MS&A PRIOR TO ANY INSTALLATION, THIS IS TO INSURE NO FIELD REVISIONS WILL BE REQUIRED. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING ANY DAMAGED CEILING TILES AND GRID OR EXTENDING ACT CEILING OR GWB CEILING AS NECESSARY TO MATCH EXISTING AS REQUIRED. 7. DAYLIGHT ZONE CONTROL: ALL DAY LIGHTED AREAS AS DEFINED IN CHAPTER 12, BOTH UNDER OVERHEAD GLAZING AND ADJACENT TO VERTICAL GLAZING, SHALL BE PROVIDED WITH INDIVIDUAL CONTROLS, OR DAYLIGHT OR OCCUPANT SENSING AUTOMATIC CONTROLS, WHICH CONTROLS THE LIGHTS INDEPENDENT OF THE GENERAL LIGHTING AREA PER 1513.3 OF THE WASHINGTON STATE ENERGY CODE. 8. CONTRACTOR IS RESPONSIBLE FOR ALL ASPECTS OF FIRE SPRINKLERS DESIGN AND CONSTRUCTION. IN THE EVENT OF A CONFLICT REGARDING NEW LIGHTS, WALLS, SOFFITS, AND OTHER FIXTURES, THE SPRINKLER HEADS MUST BE MOVED, 9. COMMISSIONING REQUIREMENTS: FOR LIGHTING CONTROLS WHICH INCLUDE DAYLIGHT OR OCCUPANT SENSING AUTOMATIC CONTROLS, AUTOMATIC SHUTOFF CONTROLS, OCCUPANCY SENSORS, OR AUTOMATIC TIME SWITCHES, THE LIGHTING CONTROLS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES, COMPONENTS, EQUIPMENT AND SYSTEMS ARE CALIBRATED, ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER, DRAWING NOTES SHALL REQUIRE COMMISSIONING IN ACCORDANCE WITH THIS NOTE, SWEEP CONTROLERS ARE NOT BUILDING STANDARD, USE OCCUPANCY SENSORS AS REQUIRED. CEILING LEGEND & NOTES NA OCCUPANT LOAD: 5,899 USF 1 :100 = 59 OCCUPANTS 2 EXITS REQUIRED, 2 EXITS PROVIDED INT ERGATE WEST BUILDING C 12101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA 98169 ITE MAP 9 NOTE: 1. THIS IS NOT A REPRESENTATION OF A LEGAL SURVEY, 6" UNLESS OTHERWISE NOTED PATH OF EGRESS TRAVEL IS LESS THAN 100' -0" DOOR NUMBER TYPE OF DOOR A. NEW B/S 3' -0" WIDE x 7' -0" HIGH S.C. MAPLE WOOD DOOR WITH B/S STEEL FRAME. HARDWARE a. B/S LOCKSET b, B/S LATCHSET, EXISTING DOOR TO REMAIN. NOTES: 1. ALL NEW HARDWARE TO MEET ALL APPLICABLE LAWS, CODES AND STANDARDS FOR BARRIER FREE COMPLIANCE. 2, KEYING FUNCTIONS TO BE COORDINATED BY TENANT. 3. RE -USE EXISTING DOORS SCHEDULED FOR REMOVAL WHEREVER POSSIBLE. DOORS TO BE RE -USED ARE TO BE TOUCHED UP TO BRING INTO "LIKE NEW' CONDITION. 4, PROVIDE WALL STOPS (FLOOR STOPS WHERE REQUIRED) AT ALL INTERIOR DOORS. ACCESSIBILITY NOTES: 1, ICC /ANSI A117.1 -2003 SECTION 40424. DOOR THRESHOLDS: THRESHOLDS AT DOORWAYS SHALL BE 1/2 INCH MAXIMUM IN HEIGHT. 2. ICC /ANSI A117.1 -2003 SECTION 404.2.6. DOOR HARDWARE: HANDLES, PULLS, LATCH, LOCKS AND OTHER OPERABLE PARTS ON ACCESSIBLE DOORS SHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST TO OPERATE. OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34 INCHES MINIMUM AND 48 INCHES MAXIMUM ABOVE THE FINISH FLOOR. 3, 404,2,8 DOOR - OPENING FORCE: FIRE DOORS SHALL HAVE THE MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY. THE MAXIMUM FORCE FOR PUSHING OPEN OR PULLING OPEN DOORS OTHER THAN FIRE DOORS SHALL BE AS FOLLOWS: a. INTERIOR HINGED DOOR: 5.0 POUND (22.2 N.) b. SLIDING OR FOLDING DOOR: 5.0 POUND (22.2 N.) THESE FORCES DO NOT APPLY TO THE FORCE REQUIRED TO RETRACT LATCH BOLTS OR DISENGAGE OTHER DEVICES THAT HOLD DOOR IN A CLOSED POSITION. DOOR SCHEDULE ti LIT "rfrrn erer.,,A#W 4 "XS:4W AraAra 2 -4414 : Aii; /Ji 1/ /I�» I:/,! lie-„re, li fjL 4, 4 F AztA LONGEST DIAGONAL NORTH n ALIGN igt "N" i 0 91.104i *WNW Weems AWN T EXISTING CONSTRUCTION TO REMAIN EXISTING CONSTRUCTION TO BE DEMOLISHED c EXISTING FULL HEIGHT RELITE TO REMAIN, EXISTING PARTIAL HEIGHT RELITE TO REMAIN. NEW STANDARD TENANT PARTITION 'A'. SEE DETAIL 1/TI -2. NEW STANDARD TENANT PARTITION 'B'. SEE DETAIL 2/TI -2, NEW FULL HEIGHT RECITE: 3' -O° WIDE IN B/S MAPLE FRAME WITH SAFETY GLASS WHERE REQUIRED. HEIGHT TO MATCH THAT OF DOOR FRAMES. NEW BIS DEMISING PARTITION AT HEADER. SEE DETAIL 3/TI -2. NEW B/S FULL HEIGHT DEMISING PARTITION. SEE DETAIL 4/TI -2, nowilimom NEW BIS FULL HEIGHT PARTITION WALL TO MATCH EXISTING, CONSTRUCTION LEGEND NTS EXISTING, U.N,O., B/S WALL MOUNTED DUPLEX ELECTRICAL OUTLET EXISTING, U.N.O., B/S WALL MOUNTED VOICE /DATA OUTLET EXISTING, U.N.O,, BLANK FACE PLATE EXISTING POWER POLE NEW TO MATCH EXISTING B/S 2. ALL COMMUNICATIONS (VOICE / DATA) LINES TO BE ROUGH -IN ONLY (MUD RING W/ PULL WIRE). NA 10 ELECTRICAL LEGEND & NOTES a NOTES: 1, ALL OUTLETS TO BE MOUNTED 15" A.F,F, - TO BOTTOM OF OUTLET PER W.S,B,F, REQUIREMENTS U.N.O. NA SCOPE OF WORK: PARTIAL FLOOR TENANT IMPROVEMENT ON THE THIRD FLOOR OF AN EXISTING OFFICE SPACE. THE WORK CONSISTS OF DEMOLITION AND CONSTRUCTION OF PARTITIONS, DOORS, RELITES, CEILINGS, AND OTHER FEATURES. THERE IS NO STRUCTURAL OR CORE AND SHELL WORK. PROJECT ADDRESS: INTERGATE WEST - BUILDING C 12101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA 98168 PARCEL NUMBER: 092304 9309 N 1/4 OF SECTION 9 THE SOUTHEAST E 0 THE NORTHEAST 1/4 OF H 9, LEGAL DESCRIPTION: BEGINNING ON THE SOUTH LINE OF TOWNSHIP 23 NORTH, RANGE 4 EAST, WM, AT A POINT 150 FEET WEST OF THE WEST MARGIN OF STATE HIGHWAY NO.1 THENCE EAST 150 FEET TO SAID WEST MARGIN, THENCE NORTHWESTERLY ALONG SAID WEST MARGIN TO A POINT 60 FEET NORTH OF, MEASURED AT RIGHT ANGLES TO, SAID SOUTH LINE, THENCE CONTINUING NORTHWESTERLY ALONG SAID MARGIN 60 FEET; THENCE SOUTHWESTERLY TO THE TRUE POINT OF BEGINNING, ALSO BEGINNING AT THE NORTHWEST CORNER OF THE PARCEL LAST ABOVE DESCRIBED, THENCE EAST PARALLEL WITH THE SOUTH LINE OF SAID SUBDIVISION TO THE CENTERLINE OF STATE HIGHWAY NO 1, THENCE NORTHWESTERLY ALONG SAID CENTERLINE 380 FEET, THENCE WEST PARALLEL WITH SAID SOUTH LINE TO A POINT 150 FEET WEST OF THE WEST MARGIN OF STATE HIGHWAY NO 1, THENCE SOUTHEASTERLY TO THE POINT OF BEGINNING, EXCEPT THAT PORTION THEREOF LYING WITHIN STATE HIGHWAY NO 1, SITUATE IN THE CITY OF TUKWILA, COUNTY 0 KING, STATE OF WASHINGTON, ZONING: TYPE OF CONSTRUCTION: OCCUPANCY: AREA OF WORK: BUILDING CODE: FIRE CODE: PLUMBING CODE: ENERGY CODE: BARRIER -FREE CODE: TENANT SPACE PLANNER: GENERAL CONTRACTOR: C /LI II, SPRINKLERED, QUICK RELEASE SPRINKLER HEADS (IN ACCORDANCE WITH N F.PA 13 AND SECTIONS 903.3,1 .1 & 903.3.2). . B (OFFICE) APPROXIMATELY 5,899 SF IBC, 2006 EDITION IFC, 2006 EDITION UPC, 2006 EDITION WASHINGTON STATE ENERGY CODE, 2(06 EDITION AMERICAN NATIONAL STANDARD ICC / ANSI A117.1, 2003 EDITION MED DATA 9709 THIRD AVENUE NE, SUITE 301, SEATTLE, WA 98115 206 -529 -9742 (P), 206 -529 -9663 (F) EMAIL: jefflo @meddata.com CONTACT: JEFF LONEY BUILDING SABEY CORPORATION REPRESENTATIVE: 12201 TUKWILA INTERNATIONAL BLVD, 4TH FLR, TUKWILA, WA 98168 206- 281 -8700 (P), 206 - 282 -9951 (F) EMAIL: marcyj@sabey,com CONTACT: MARCY JENKINS MARVIN STEIN AND ASSOCIATES, LLC 2221 5TH AVENUE, SEATTLE, WA 98121 206-441 -1449 (P), 206. 4414361 (F) EMAIL: s,navarro@marvinstein,com CONTACT: STEVE NAVARRO TBD EMAIL: CONTACT: 1. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL WORKAND MATERIALS IN ACCORDANCE WITH ALL APPLICABLE CITY, COUNTY, AND LOCAL BUILDING AND FIRE CODES AS REQUIRED, 2. CONTRACTOR SHALL BE GOVERNED BY ALL CONDITIONS AS INDICATED IN CONTRACT DRAWINGS & SPECIFICATIONS FOR BUILDING. 3. CONTRACTOR SHALL VISIT JOB SITE AND VERIFY ALL FIELD DIMENSIONS AND CONDITIONS AND NOTIFY MS&A OF ANY DISCREPANCIES BEFORE PROCEEDING WITH WORK. 4. B/S INDICATES "BUILDING STANDARD" AS PROVIDED BY LANDLORD DRAWN AND /OR SPECIFIED IN BUILDING CONTRACT DOCUMENTS. 5. DIMENSIONS TO AND OF ELECTRICAL & TELEPHONE OUTLETS INDICATES MAXIMUM OF 6" FROM CENTERLINE OF ELECTRICAL OUTLET TO CENTERLINE OF TELEPHONE OUTLET. 6, CONTRACTOR TO OBTAIN ALL PERMITS AND APPROVALS, UNLESS NOTED OTHERWISE. 7. WALLS AND CEILINGS TO BE INDEPENDENTLY SUPPORTED, FOR SEISMIC CONDITIONS, IN BUILDING JURISDICTIONS WHERE APPLICABLE. 8. CONTRACTOR TO PROVIDE BLOCKING AT ALL WALL MOUNTED ITEMS. 9. CONTRACTOR SHALL ALIGN OR FURR ALL INTERIOR PARTITITONS SO THAT FINISHES REMAIN FLUSH IN ROOMS AND CORRIDORS REGARDLESS OF DIFFERENCES IN PARTITION WIDTHS. 10, CONTRACTOR TO PROVIDE LEVELING THROUGHOUT THE SPACE FOR PROPER INSTALLATION OF EQUIPMENT, PARTITIONS, DOORS, GLUE -DOWN CARPET, ETC, TOLERANCE OF 1/4' IN 10' -0" DIFFERENCE IS ACCEPTABLE, GENERAL NOTES NA E C Permit No Plar review approval is sub oct to errors end cm!! Approval of construction documents Goes not cut he violation of any adopted code or ordinanco. R TI -3 DEMOLITION/ CONSTRUCTION PLA TI -1 COVER SHEET AND NOTES TI -2 NOTES AND DETAILS TI -4 REFLECTED CEILING PLAN By TI -5 ELECTRICAL/ COMMUNICATIONS PLAN REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. 11 DRAWING INDEX Py approved Field Copy and conditions is ache o'wk Date. City of Tukwila BUILDING DIVISION SEPARATE PERMIT REQUIRED FOR: C1 Mechanical sif Electrical Plumbing [YGas Piping City of Tukwil r1 ! • INTERGATE WEST BUILDING C 12101 TUKWILA INTERNATIONAL BLVD. TUKWILA, WASHINGTON 98168 Marvin Ste ►sociates, LLC planning v design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 NO. TENANT: MED DATA RECEIVED EXPANSION NOV 132008 PERMIT CENTEF SHEET TITLE: THIRD FLOOR COVER SHEET AND NOTES REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESS PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS&A 2007. TI -1 OF