HomeMy WebLinkAboutPermit D06-132 - Alside - Storage RacksALSIDE 6701 GLACIER ST D06 -132 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 7888900091 Address: 6701 S GLACIER ST TUKW Suite No: Tenant: Name: ALSIDE Address: 6701 S GLACIER ST, TUKWILA WA Owner: Name: GRUBMAN WILLIAM I Phone: Address: 9536 WILSHIRE BLVD #310, BEVERLY HILLS CA Contact Person: Name: MICHAEL O'BRIEN Phone: 425 557 -0712 Address: 5837 221 PL S, ISSAQUAH WA Contractor: Name: NEW WEST CONSTRUCTION INC Phone: 425 -557 -0712 Address: 5837 221ST. PL SE, ISSAQUAH, WA Contractor License No: NEWWECI110CP Expiration Date:09/21/2006 DESCRIPTION OF WORK: INSTALL STORAGE RACKS IN EXISTING WAREHOUSE SPACE. PARTIAL NEW RACKS, MOST RACKS RELOCATED FROM PREVIOUS SPACE. Value of Construction: $0.00 Type of Fire Protection: Type of Construction: Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N doc: Devperm DEVELOPMENT PERMIT Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N ** Continued Next Page ** Permit Number: D06 -132 Issue Date: 05/18/2006 Permit Expires On: 11/14/2006 Fees Collected: Uniform Building Code Edition: Occupancy per UBC: $375.06 D06 -132 Printed: 05- 18-2006 City of Tukwila Permit Center Authorized Signature: Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constructjon or the ormance of work. I am authorized to sign and obtain this development permit. Date: S/I 8 J. Signature: Print Name: KYHN This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last Inspection. doe: Devperm 006 -132 Printed: 05 -18 -2006 doc: Conditions Tukwila City of Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 7888900091 Address: 6701 S GLACIER ST TUKW Suite No: Tenant: ALSIDE 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 7: ** *FIRE DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS Permit Number: D06-132 Status: ISSUED Applied Date: 04/13/2006 Issue Date: 05/18/2006 2: No changes shall be made to the approved plans unless approved by the design professional In responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: All electrical work shall be inspected and approved under a separate permit Issued by the Washington State Department of Labor and Industries (206/248- 6630). 6: VALIDITY OF PERMIT: The Issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 9: The total number of fire extinguishers required for an extra hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,000 sq. ft. of area. The extinguishers) should be of the "all purpose" (4A 40 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 10: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's Installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the Installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 11: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to Indicate the locations of the extinguishers. (IFC 906.6) 12: Extinguishers shall be located In conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed Indicates the need for placement away from normal paths of travel. (IFC 906.5) D06 -132 Printed: 05 -18 -2006 tukwila City of Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 13: Fire extinguishers require monthly and yearly Inspections. They must have a tag or label securely attached that indicates the month and year that the Inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly Inspections of the fire extinguisher(s) are not accomplished or the Inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4-4) 14: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 15: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from Inside the tenant space. (IFC Chapter 10) 16: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 17: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 18: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs In cases where the exit or the path of egress travel is not Immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor Is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever Is less, from the nearest visible exit sign. (IFC 1011.1) 19: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT' shall have letters having a width not less than 2 Inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established In section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT' shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 20: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 21: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress Is occupied. The means of egress illumination level shall not be less than 1 foot-candle (11 lux) at the floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 22: Aisles in sprinkiered buildings shall be a minimum of 44 Inches (1118 mm) wide. Aisles shall be a minimum of 96 inches (2438 mm) wide in high -piled storage areas exceeding 2,500 square feet (232 m in area, that area accessible to the public and designated to contain high - hazard commodities. Aisles shall be a minimum of 96 inches (2438 mm) wide in areas accessible to the public where mechanical stocking methods are used. (IFC 2306.9.1.1) 23: The required aisle width shall extend from floor to ceiling. Rack structural supports and catwalks are allowed to cross aisles at a minimum height of 6 feet 8 inches (2032 mm) above the finished floor level, provided that such supports do doc: Conditions D06 -132 Printed: 05-18 -2006 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 not interfere with fire department hose stream trajectory. (IFC 2306.9.2) 24: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 25: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 26: Maintain fire alarm system audible /visual notification. Addition /relocation of walls or partitions may require relocation and /or addition of audible /visual notification devices. (City Ordinance #2051) 27: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 28: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 29: Nominal 6" transverse flue spaces between loads and at rack uprights shall be maintained in single row, double row, and multiple row racks. Random variations In the width of flue spaces or in their vertical alignment shall be permitted. (NFPA 13- 12.3.1.13) 30: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors In sprinklered areas of buildings. (IFC 315.2.1) 31: Vinyl siding storage not to exceed 15 ft. total height. 32: Foam insulation storage(Group A plastic) not to exceed 5 ft. total height measured from the floor. 33: Contact The Tukwila Fire Prevention Bureau to witness all required Inspections and tests. (City Ordinances #2050 and #2051) 34: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 35: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doe: Conditions * *continued on next page ** D06 -132 Printed: 05- 18-2006 doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Date: s/1 &'O 6 Print Name: It'/Pm Q 11.6£ 006 -132 Printed: 05-18 -2006 CITY OF TUKWILA..." Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print'* Site Address: 67 01 5. Ct 4 c i pP l l Tenant Name: A L S ih a Property Owners Name: WI 1 Q M 6k1 Mailing Address: '7 3 E$ W /L I WIRE LM S ulam 3/0 /0 ' [Y �ll� s CQ / 0 2 /2 (y ,State Zip Day Telephone: q26 5-57,- 0 1 �5 AQ uAk tA %o27 Coy t / State Zi E -Mail Address: M vls RAEN e nom/ S E P ✓1 ca c b4 7 Fax Number: ZS ^ 537 – 071$ Name: M ' 4 - 0! 13 nt le t - Q RCi-ii Mailing Address: 1 R s 7 n i A FL 'S Building Permit No. Mechanical Permit No Pltunbirigloas Permit No Public Works Permit No Project No. (For Qrae use only) King Co Assessor's Tax No.: 78 Suite Number. —' Floor: I Sr New Tenant: g.... Yes ❑ ..No GENERAL CONTRACTOR INFORMATION – (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg Company Name: IU1 LtJ (A i S`t" Cn&4,S`r RU CTl tW NO Mailing Address: S R 37 , Zz) st PL eSt. 1 s Aq oill 1A)A 913o;7 Cit State Zip Contact Person: TZ)CCo telat Day Telephone: 4 /.24 -- - i cy 0712- E -Mail Address: R - rap p�' t�. i EU)W X75 ✓CCES, GOk Fax Number: yZ 5 - ,S3 7 - n7/6 Contractor Registration Number: Expiration Date: [ARCHITECT OF RECORD — Ail plans must be wet stamped by Architect of Record Company Name: Mailing Address: Contact Person: E -Mail Address: Company Name: Mailing Address: City Contact Person: Day Telephone: E - Mail Address: Fax Number: QMpplicatimulporms-Applicetio u On Line\ -2006 - Parma Applica ondoc Revised: 42006 N' City Day Telephone: Fax Number: State Zip F E$GINE RECORD - All plans must be wet stamped by Engineer of Record State Zip Page I of 6 Valuation of Project (contractor's bid price): $ ), on c O Scope of Work (please provide detailed information): SPAc,&_. - fl RI1Ai- MPtw &4cK Q: Appliations\Fmms- Applications On Line \3 -2006 - Penult Appliation.doc Revised: 4-2006 nn Existing Building Valuation: $ Lo CA PACP Will there be new rack storage? .Yes ❑ .. No (If yes, a separate permit and plan submittal will be required) Provide All Building Areas in Square Footage Below_- r Floor Floors Basement Accessory Structures Attached Garage Detached Gauge Attach Croon hed Carport Covered Deck recovered Deck Existing Interior Remodel Addition to Existing Structure Type of Construction per IBC Type of Occupancy per IBC PLANNING DIVISION: Single - family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ ....Yes ❑ ..No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 0.. Sprinklers ❑..Automatic Fire Alarm ❑..None ❑ . Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ ..Yes ❑ -No If "yes", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets. SEPTIC SYSTEM: On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 PERMIT APPLICATION NOTE - Applicable to all permits in this a ieation Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW R UT }) AAGEN t� Signature: 4L 6 1�./v� ---te /ti60/7 Fo&. OtD,V Date: 5 03 D�p Print Name: / CPA A, 046 Day Telephone: V2 5 - �j S - 07/2- Mailing Address: S 37 - 224 st FZ S.E ! SSA) °i41 -r w46 9$ %�� City State Zi Date Application Expires: 10 (2) 'cte I Date Application Accepted: Q: Appauuoawmae- Applications On taneV -2006- Permit Application doe Revised: 42006 bb Page 6 of 6 Fixture Type:. Qty . Fixture Typ -• .Qty Fixture Ty w . , Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking foun or water cooler (per head) Wash foun -;- Gas piping outlets Bidet - Food -waste grinder, commercial Recep • , indirect wash Clothes washer, domestic Floor drain Si Dental unit, cuspidor Shower, single head trap inals Dishwasher, domestic, with independent drain Lavatory ater Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treatin equipment . ' epair or alteration drainage or vent pi .•ng Medical gas piping system serving one to five inlets/outlets for specific gas Additional medical •.L inlets/outlets — six more PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Day Telephone: Fax Number: Contractor Registration Number: Expiration Date: f Contact Person: E -Mail Address: Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Indicate type of plumbing fixtures and/or g piping outlets being installed and the u -tt City below: Q■pplicationsWoane- Applications On Line 3 -3006 -Pamir Applimion doc Revised: 4-2006 bit Page 5 of 6 Payee: ALSIDE TRANSACTION LIST: Type Method Description Amount ACCOUNT ITEM LIST: Description Current Pmts City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE 000/322.100 000/345.830 000/386.904 RECEIPT Parcel No.: 7888900091 Permit Number: D06 -132 Address: 6701 S GLACIER ST TUKW Status: PENDING Suite No: Applied Date: 04/13/2006 Applicant: ALSIDE Issue Date: Receipt No.: R06 -00500 Payment Amount: 375.06 Initials: JEM Payment Date: 04/13/2006 03:04 PM User ID: 1165 Balance: $0.00 Payment Check 465689 375.06 Account Code 224.58 145.98 4.50 Total: 375.06 4515 04/13 9716 TOTAL 375.06 doc: Receipt Printed: 04-13 -2006 Project: Type of Inspection: Address. 7W c_)4. Date ailed: Special Date Wanted: 2— a . P equester. Phone No: INSPECTION RECORD INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION F- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-36 V k proved - per - a plicable codes. COMMENTS: 'Lriza- El $58.11 *EINSPECTION #E REQUI ED. Prior o inspection, fee must be paid at 6300 Southcent r Blvd.. Suite 100. Call the schedule reinspection. r eceipt No.: IDate: Retain a copy with permit Corrections required ptiararoyal. Project: A h . r� Si p� Type of Inspection: f a' >,r Date Ca le _ / Address: / � y// 77 /✓ r , Special instructions: Date Wanted: �� a.m. p.m. Requesteer:: z � Phone No v0-C 7-9/ - 9 /l/ INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 60 c 6,r7 /10') -S ri Ave, f7 /a a SP Allis r/4 , /ham, t el 7P Ail / ic p % 0 $58.00 REINSPECTION � REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Cal the schedule reinspection. (Receipt No.: IDate: 1 Project: 1 S;.l� Type of Inspection: t fO , /- 41 Addre �7 Date Called: Special Instructions: (0o 25T9/ Date Wanted: > a l`24, a7 Requester Ere( /3 Phone No 2 /7 s 297 — Y6/ INSPECT N NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 COMMENTS: l� R� .v r ,f ( r % r�o. »(a e !i-e4 pia / s fit 4r dt rc, r.S'- .Z, 0 • 44 / El Approyed per applicable codes. `Receipt No.: (Date: INSPECTION RECORD Retain a copy with permit $58.b0 REINSPECTION PtE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. (206)431 -3¢7 ,Corrections required prior to approval. Project: Au4 1ot:5 t I Type of Inspection: ' a Reis it / RAG a l7N4 c- Address: G 90 i 5. Suite #: GLAG,E-yf Contact Person: (Rq ,/2, Special Instructions: Occupancy Type: Phone No.: gic 1T /- 47 / Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: 3 INSPECTION NUMBER Approved per applicable codes. Word /Inspection Record Form.Doc INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT 12/2/05 Do 1 PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 — corrections required prior to approval. COMMENTS: — Et cr 46 MVO) A'/- - / r/A4 *iA-rr t/-y -erne e- 1 Zr our /DE tF 6 hi rx rr tan — /4.'4! l i NsA C OX Inspector: i /Z Date: /he �O Hrs.: "I ❑ $80.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 444 Andover Park East. Call to 'schedule reinspection. Receipt No.: Date: T.F.D. Form F.P. 85 , 07/23/2007 18:22 704- 549 -4946 FAX MESSAGE DATE: Monday, July 23, 2007 NO. OF PAGES: 9 ATTN: MESSAGE: Thanks, CHASE EQUIPMENT CO. 118 WEST STREETSBORO ROAD #213 HUDSON OH 44235 TEL. 330 - 650.3881 FAX. 330-342-9501 Ch24fS, Terry L. Yonker Chase Equipment Co. UNIVERSITY COURTYARD ` PAGE 01/09 RECEIVED DEC 0 5 2007 PERMIT CENTEF LEVELS =2 HI =90 h+. H2.84w PANELS = LIVE LOAD =2000 lbs. FRAME HEIGHT = 180 Ia. W2 W1�20001bs. W2 =MOO lb s. H Y1 =54k Y2 =54i Y3 = St i' H2 WI Y3 Y 2 FRAME DEPTH = 48 in. BEAM LENGTH - 108 iw. SEISMIC CATEGORY = (Fa =1, Ss =1.537) TYPE - SINGLE ROW .� Ht --.- Yt / - L MAN(1FACTURER = 1TXRE ' 'l.4---- L L — '-f 0 ''I' ( COLUMN BEAM 0 Level 1 CONNECTOR Q. Level 1 OK 3xSx14ga Steel = 55000 psi Stress x=72% OK StepBeam 41/42.75 "x16ga Steel P. 55000 psi Max Static Capacity = 3667 lb. Stress = 55% OK THREE PIN CONNECTOR Stress = SPY. COLUMN BACKER BEAM @ Level 2+ CONNECTOR Q Level 2+ None Stress n OK StepBeam 4"s2.75 "xl6ga Max Static Capacity =3667 lb. Stress = 55% OK THREE PIN CONNECTOR Stress = 30% BRACING SLAB & SOIL HORIZONTAL OK 1 In X I X 14CtA Stress= 16% DIAGONAL OK 1 1/2 X 1 X 140A . Stress =57% Slab = 5' X 2000 psi Ranforeed OK Soil Bearing Pressure : 1000 psf Slab Puncture Stress = ' . Slab nan *ts = 34% BASF PLATE ANCHORS 3.125 In X 4.5 in X 0.125 in Steel a 36000 psi MBase = 0 in. lb. OK - • • .1 - • Trubolt 0.5 Dia. X 2.25 Kn. , . d. OK Pullout Capacity = 580 lbs. Shear Capacity = 1190 lbs, No. Of Anchors =1 per Base Plate or ... ed _. .. Anchor Stuns = 6% NOTES: Design based on 200316C for sip code 98188 vi/Fr 1.0 & Ss= 1.337. Design loading is 2,0009/level. ` Cele- ear - 07/23/2007 18:22 704- 549 -4946 Jul 20 07 07:45a Car MATERIAL HANDLINO ENGINEERING TEL: (909)869.0989 FAX: (909)869 - 0981 161 A7IANTIC STREET.POMONA_ CA 91768 COMPONENTS & SPECWICA'TlON.S : t ype 194-9 ANALYSIS PER SECTION 2210 OF THE 2000 IBC SITE CLASS = D UNIVERSITY COURTYARD 5099690961 PAGE 02/09 P . PROJECT Alside Supply Center WA. 98188 ibc FOR Chase Equipment (Terry Y.) SHEET NO. I i CALCULATED BY ny obi DA'Z'E 7/19/2007 COM1'ONEWX S & SPECIFTCATXONS : Type 194-10 ANALYSIS PER SECTION 2210 OF THE 2000 IBC SITE CLASS - D . H1 W 2 wI- 130011 W2 =1300 lbs_ Yl - Si t Y2 = Sl i LEVE - 2 HZ • 36 u =461x. F PANELS - 2 LIVE WAD a 1500 lbs. FRAME HEIGHT -120 i . H T WI . Y2 FRAME DEPTH =.48 in. BEAM LENGTH- 51 in. SEISMIC CATEGORY "+ D (Fa a 1, Ss a 1337) TYPE - SINGLE ROW HI H vt MANUFACTURER - I'I'YPE 'I--- L - "' 0 - 4 s L VAIN fl n Level 1 ON s ' @ Level OK 3x1- 5/8x13ga Steel - 55000 psi Stress r41%" OK StepBeam 4 "x2.75"x16ga Steel - 55000 psi Max Static Capacity - 8206 lb. Stress - 15% OX THREE PIN CONNECTOR Stress = 28% COLUMN BACKER BEAM @ Level 2+ CONNECTOR @ Level 2+ None Stress - OK StepBea.a 4 "s2.75"x16ga Max Static Capacity - 8206 lb. Stress - 187E OK THREE PIN CONNF,CTOR Stress - 9% BRACING SLAB & SOIL HORIZONTAL OK 11/2 X 1 X 14GA Stress =14% DIAGONAL OK 1 1/2 X 1 X 14(3A Stress - 44% Slab - 5" X 2000 psi Reinforced OK Soil Bearing Pressure c 1000 psf Slab Puncture Stress - 24% Slab 4% BASE PLATE ANCHORS 3,125 in X4.5 MX 0.125 Steels 36000 psi MBasc - 0 hi. lb. tress - (1% OK d Ttttbolt 05 Dia. X 2.25 Ml Pullout Capacity - 580 lbs. Shear Capacity - 1190 Ibs No. Of Anchors - I per Ba (or approved eau Anchor Stress - 4 . Embd. OK late NOTES: Design based on 2003 IBC for zip code 98188 w/ Fa- 1.0 & Sr 1337. Design loading is 1,50Oii/level. N o CtUvale 07/ 18:22 704 - 549 -4946 UNIVERSITY COURTYARD Jul 20 07 07:45a 1 4SEIZMIC MATERIAL HANDLING ENGINEERING TEL : (909)869 - 0989 FAX : (909)869 0981 61 ATLANTTC STRE ET. POMONA. CA 917 90905303/31 DATE 7/1 PAGE 03/09 p.3 PROJECT Alside Supply Center WA 98188112 FOR Chase Equipment (Terry Y.) SLEET NO. 2 /g CALCULATED BY to obi LEVELS -2 H1 -soils W2 w1 =28W0lb: 60 - - YI=5�i 1i2 = in. 1 w2 :2150 (r \ Y2 =5)i PANELS ' LIVE LOAD = 2800 lbs. H2 Y2 FRAME HEIGHT =120 in. H ? WI FRAME DEPTH ■ 48 in. - BEAM LENGTH = 108 in. Y1 SEISMIC CATEGORY D Ht (Fa • I, S: a ].337) TYPE • - SINGLE ROW .� ?"� J MANUFACTURER - ITYPE L "' D COLUMN BEAM (P} Level 1 CONNECTOR @ Levet 1 OK OK OK 3x1- 5/8x13ga StepBeam 4 "1¢.75 "xl6ga THREE PIN CONNECTOR Steel as 55000 psi Steel - 55000 psi Stress - 73% Stress -96% Max Static Capacity - 3667 lb. Stress - 76% COLUMN BACKER BEAM ® Level 2+ CONNECTOR @ Level 2+ OK OK stepper= 4"1(2,75'5cl6ga THREE PIN CONNECTOR None Max Static Capacity = 3667 Ib. Stress to 28%. Stress - Stress - 76% . BRACING SLAB & SOIL HORIZONTAL OK DIAGONAL OK Slab+• 5' X 2000 psi kdnfbrced OK Soil Bearing Pressure - 1000 psf 1 1/2 X I X 140A 1 1/2 XI X 140A Slab Puncture Stress - 49•/ Stress ■ 25 - 79% Slab Bending-6lres6aL 46V. BASE PLATE ANCHORS OK Ramset/Redbe bolt 0.5 flit X 225 Mn. OK 3.125 to X 4.5 in X 0.125 in Pullout Capacity - 580 lbs. Steel "" 36000 psi Shear Capacity - 1190 lbs. MBase - 0 in. lb. o. Of Anchors -1 per Base Plate Stress - 0% (or approved equal) b Stress - 11% NOTES: Design based on 2003 IBC for zip code 98188 w/ Fa- 1.0 & Ss= 1.337. Design loading reduced to 2,8004/Ievet 07/23/2007 18:22 704- 549 -4946 Jul 20 07 07:450 SEIZMIC MATERIAL HANDLING ENGINEERING TEL :4909)869 - 0989 FAX : (909)869 - 0981 161 ATLANTIC STREET. POMONA. CA 91768 COMPONENTS & SPECIFICATIONS : Twig 194-7 ANALYSIS PER SECTION 2210 OF THE 2000 IBC SITE CLASS UNIVERSITY COURTYARD 9098690981 D PAGE 04/09 p. PROJECT Abide Supply Cadet WA 98188 the FOR Chase Equipment (Terry Y.) SHEET NO. 3 / CALCULATED BY m, obi DATE 7/19/2007 07/23/2007 18:22 704- 549 -4946 Jul 20 07 07:450 SEIZMIC MATERIAL HANDLING ENGINEERING TEL :4909)869 - 0989 FAX : (909)869 - 0981 161 ATLANTIC STREET. POMONA. CA 91768 COMPONENTS & SPECIFICATIONS : Twig 194-7 ANALYSIS PER SECTION 2210 OF THE 2000 IBC SITE CLASS UNIVERSITY COURTYARD 9098690981 D PAGE 04/09 p. PROJECT Abide Supply Cadet WA 98188 the FOR Chase Equipment (Terry Y.) SHEET NO. 3 / CALCULATED BY m, obi DATE 7/19/2007 COMPONENTS & SPECIFICATIONS, : Time 194-3 ANALYSIS PER SECTION 2210 OF THE 2000 IBC SITE CLASS • D LEVELS =3 HIa46ia. H2 a36 in. PANELS • 2 11138 in. LIVE LOAD • ISOO Ibs. FRAME HEIGHT =120 in. FRAME DEPTH = 48 in. BEAM LENGTH- 51 in. W3 WI 0150014. W2- 1300 W3 - I500Itn. Yt =Sli Y2=51 H3 ir wz Y2 H H2 uv 1 H Y1 SEISMIC CATEGORY • D (1 awl, Ss =1.337) TYPE - SINGLE ROW Ht ,l N 4- O MANUFACTURER = 1TYPE -I' L COLUMN BEAM Iii Level I CONNECTOR ® Level 1 OK 3x1- 5/8x13ga Steel - 55000 psi Stress =62% OK StepBearn 4•x2.751/416ga Steel • 55000 psi Max Static Capacity - 8206 lb, Strew =18X. OK THREE PIN CONNECTOR Stress • 42% COLUMN BACKER BEAM () Level 2+ CONNECTOR ® Level 2+ None Stets • OX StepBeam 4'5C 75"x16ga Max Static Capacity Is 8206 lb. Stress =18% OK THREE PIN CONNECTOR Stress = 2070 BRACING SLAB & SOIL • HORIZONTAL OK 1 1/2X 1 X 14GA Stress • 217• �+—'--. DIAGONAL OK 1/Z X 1 X 14GA ss = 66% Slab • 5" X 2000 psi Reinforced OK Soil Bearing Pressure = 1 000 psf Slab Puncture S Slab B i ress = • ASE PLATE I ANCHORS OK 3.125 is X 4,5 in X 0.125 is Steil vs 36000 psi Meese • 0 in. lb. Stress • 0• Ram : -• Trubolt 0.5 Die. X 2.25 Mta. E Pullout Capacity - 580 lbs. Shear Capacity • 1190lbs. No. Of Anchors • 1 per Base P e (or aooroved eaual) _ Pbd. OK NOTES: Design based on 2003 IBC for sip code 98188 w/ Fe= 1.0 & Ss = 1.337. Design loading la 1,5000/level, N ° ine 07/23/2007 18:22 704- 549 -4946 UNIVERSITY COURTYARD Jul 20 07 07:46a E M IC MATERIAL HANDLING ENGINEERING TEL ; (909)869.0989 FAX : (909)869.0981 61 ATLANTIC STREET. POMONA. C 9 176 9096690981 PAGE 05/09 p.5 PROJECT Abide Supply Center WA 98188 the FOR Chase Equipment (Terry Y) SHEET NO. 4 /9 CALCULATED BY m. obi DATE 719/2007 COMPONENTS & SPECIFICATIONS : Tvoe 194-8 • ANALYSIS PER SECTION 22I0 OF THE 2000 IBC SITE CLASS - A LEVELS =♦ H1 = 401x. HI -20 in. PANELS - H3 X30 i. 114 -DO i». LIVE LOAD - 1300 lbs. FRAME HEIGHT = 120 in. w4 W1 =1300 W2 n15001W W3 =t300 W4 150016.. t Yl -5t: H4 w 3 �c� Y2 I Y2 =51 H3 W2 H dr H FRAME DEPTH -48 in. sum LENGTH- 108 in. SEISMIC CATEGORY - D (Fa • I, Ss - 1.337) - SINGLE ROW H2 -' so l W t Y1 Jc . D MANUFACTURER - ITYPE .4 -- L COLUMN BEAM 0 Level l CONNECTORt (R) Level I OK 34 5/8x13ga Steel • 55000 psi Stress •75% OK StepBeam 4 "x2.75 "xl6ga Steel - 55000 psi Max Static Capacity" 3667 lb. Stress - 41% OK THREE PIN CONNECTOR Stress = 47% COLUMN BACKER BEAM (6 Level 2+ CONNECTOR t4) Level 2+ • None Stress - OIC StepBear 4 "x2.75 "xl6ga Max Static Capacity ; 3667 lb. Stress • 41% OK THREE PIN CONNECTOR Stress -23% BRACING SLAB & SOIL HORIZONTAL OK DIAGONAL OK 1 12XIX14GA 11/2XIX14GA Stress - 28% Stress - 89% Slab - 5" X 2000 psi Reinforced OK Soil Bearing Pressure • 1000 psf ...'l -52% Slab Beading Stress >• OK 3.125 in X 4.5 in X 0.125 in Steel - 36000 psi Maze • 0 in. lb. Stress - 0" e Trubolt 0.5 Dia. X 2.25 Min. Bmbd. OK Pullout Capacity = 580 lbs. Shear Capacity -1190 lbs. No. Of Anchors • 1 per Base Platt . r... . vtd -• Anchor Stress - 13% NOTES: Design • 98188 w/ Pa- 1.0 & Ss- 1.337. - Design loading is 1,5000/level. . -.. zip code 1vO C 67/23/2667 18:22 704- 549 -4946 Jul 20 07 07:46a u ��IZ • UNIVERSITY COURTYARD 9098690981 PROJECT FOR SHEET NO. CALCULATED BY DATE MATERIAL HANDLNG ENGINEERING TEL : (909)869 FAX : (909)869 0981 61 ATLANTIC STREET. POMONA. CA 91768 PAGE 06/09 P.6 Alside Supply Center WA 98188 lbc Chas Equipment (Tony Y.) 5 m. obi 7/19/2007 COMPONENTS do SPECIFICATIONS : Tyre 194-6 ANALYSIS PER SECTION 2210 OF THE 20001BC • SITE CLASS = D LEVELS -4 Hl = 30 in 112 =30 in. PANELS - 2 143 = 30 in. H4 = 30 in. W 4 - WI *1500 lbs. W2 =1500 lbs. W3 =1500 lbs . W4 =1500 lb. Yt=sli Y2 =Sli 1•44 i w3 — 'Y2 I LIVE LOAD =1500 lbs. FRAME HEIGHT = 120 in. H7 H w 2 WI FRAME DEPTH • 43 in. BEAM LENGTH= 511a. (Fa 1, Ss -137) = D (FA•!, Ss -1337) TYPE = SINGLE!ROW N. d r 1 1.41 ,l H VI MANUFACTURER = !TYPE 4 L o -4 COJLTIM(1•T BEAM ® Level 1 CONNECTOR ® Level 1 OK 3x1- 5/8xI3ga Steel - 55000 psi Stress - 60% OK StepBeanr 4 "x2,755t16ga Steel • 55000 psi Max Static Capacity • 8206 lb. OK THREE PIN CONNECTOR Stress • 40% • "i ri` : A eY / • : "r ® Isvel 2h CO N OR ® el 74. Nose Stress at OK Stepfeata 4"x2.75"x16ga Max Static Capacity - 82061b. Stress • 18% OK THREE PIN CONNECTOR Stress • 25% ' BRACING SLAB & SOIL HORIZONTAL OK 1 1/2 X 1 X 14GA Stress - 23% DIAGONAL OK 1 I/2 X 1 X 14GA Stress - 89% Slab • 5" X 2000 psi Reinforced OK Soil Bearing Pressure • 1000 psf Slab Puncture Stress • 52% Slab $eadev.Stre s Ely. Yr� Tr,,' ANCRORS 3.125 in X 4.5 in X 0.125 in Steel - 36000 psi MBase - 0 in. lb. Stress • 0% OK ead Trubolt 0,5 Diu X 2.25 Mn. d. OK Pullout Capacity = 580 lbs. Shear Capacity • 1190 lbs. o. Of Anchors - 1 per Base P (or approved tonal) Str • NOTES: Design bas on for sip code 98188 •r/ Fat- 1.0 & Ss - 1337. Design loading Is 1,500)i/ltvel N 0 I/V� A i 07/23/2007 18:22 704- 549 -4946 UNIVERSITY COURTYARD Ju1 20 07 07:46a E t c MATERIAL HANDLING ENGINEERING TEL : (909)869 - 0989 FAX : (909)869.0981 161 ATLANTIC STREET. POM ONA. CA 91768 9090550901 DATE 7/19 PAGE 07/09 p.7 PROJECT Alside Supply Center WA 98188 ibc FOR Chase Equipment (Terry Y.) SHEET NO. 6/3 CALCULATED BY in an COMPONENTS & SPECIFICATIONS ; Tips 19412 ANALYSIS PER SECTION 2210 OF THE 2000 IBC SITE CLASS = D LEVELS -3 Ht =401n. 112 PI4O ie. PANELS =2 113a40,n LTV'E LOAD -2000 lbs. FRAMENP.IGHT -120 in. FRAM$ DEPTH= 481 W. SEAM LENGTH = 19S ha. 'NS W1 020001bs. W2 M0001bs W3=2000li Yl = Sri Y2 s Sr i H3 W2 Y2 H H2 w t Yt SEISMIC CATEGORY (Fa =1, )C (Fa 3: •1.337) TYPE = SE IGLE ROW Ht I 4.----- L D 4 MANUFACTURER =1TYPE "' COLUMN BEAM ® Level 1 CONNECTOR ® Level I OK 3x1- 5/8x13ga Steel = 55000 psi Stress -13% OK StepBeam 4" x2.75"xl6ga Steel ■ 55000 psi Max Static Capacity • 3667 lb. tress = 55% OK THREE PIN CONNECTOR Stress - 55% t L s BA a� R BEAM 04 Level 2+ CO A t ' ® Level 2+ None Stress = OK StepSeam 4'x2.75 "xl6ga Max StatiC Capataty - 3667 lb. Stress = 55% OK THREE PIN CONNECTOR Stress - 32% BRACING • SLAB & SOIL HORIZONTAL OK 1 1/2 X I X 14GA Stress = 28Y. DIAGONAL OK 1 1!2 X 1 X 14GA tress = 8794 Slab = 5^ X 2000 psi Reinforced OK Soil Bearing Pressure = 1000 psf Slab Puncture Stress = 52Y. Slab Bending,Sugss-31% _...ms 4.34.aia.in.YaBa AN 41i • R 3.125 in X 4.5 is X 0.125 in Steel - 36000 psi MBase = 0 It lb. Stress - 0% OK - a ead Trubolt 0.5 Dia. X 225 Min. - .. Pullout Capacity = 580 lbs. Shear Capacity = 1190 lbs. No. Of Anchors = 1 per Base Plate (or approved Anchor Stress - 13% OK NOTES: Design bas • • p code 98188 w/ Fa= 1.0 k Ss= 1.337. Design Imam is VV„ ' i 2.0008 �'�, /v O 07/23/2007 18:22 704 549 - 4946 UNIVERSITY COURTYARD Jul 20 07 07:46a . Stwt;;17 . MATERIAL HANDLING ENGINEERING TEL : (9091869 - 0989 FAX : (909)869 - 0981 161 ATLANTIC STREET_ POMONA CA 91768 9098690981 DATE 7/19/200 PAGE 08/09 p.8 PROJECT Alside Supply Center WA 98188 ibe FOR Chase Equipment (Terry Y.) MET NO. 7/3? CALCULATED BY Tn. COMTONKNTS & SPECIFICATIONS : Tyne 194-1 ANALYSIS PER SECTION 22I0 OF THE 2000 IBC ° SITE CLASS - D LEVELS - H] =62 in. H2 3018 PANELS - 2 H3 -30 In. LIVE LOAD - 15001bx. FRAME HEIGHT -120 in. FRAME DEPTH = 48 iu. SEAM LENGTH - SR in. SEISMIC CATEGORY =1C (>!n - X. Ss =X.337) TYPE - SINGLE ROW , W9 WI- 15o01bs W3 =1560 5001bs. 1bs. - 13 Y2-51i - F W2 r2 H -'s-- w t H2 H1 YI ,l ` 0 -* MANUFACTURER - mat 'f—"""' L COLUMN BtA111 a@ Level 1 CONNECTOR ® Level 1 OK 3x1- 5/8x13ga Steel = 55000 psi Stress a81% OK StepBearn 4"x2.75'x16ga Steel = 55000 psi Max Static Capacity= 8206 lb. Stress= I8% OK THREE PIN CONNECTOR Stress = SO% COLUMN BACKER BEAM rg3 Level 2+ CONNECTOR ® Level 2+ None Stress a OK StepBeun 4'275"x16ga Max Static Capacity = 8206 ID. Stress • 18% OK THAE6 PRN CONNECTOR Stress -15% BRACING SLAB & SOIL HORIZONTAL OK DIAGONAL ' OK 1 1/2X 1 X 14OA 1 1/2 X 1 X 14GA Stress = 21'/. Stress •• 66•/. Slab = 5" X 2000 psi Reinforced OK Soil Bearing Pressure - 1000 psf Slab Puncture Stress = 40% S1 : -.•" . ' • -.. -34% ASE PLATE : . a : '�` 3.115 in X4.5 is X 0.125 in Steel - 36000 psi MBasn = 0 in. lb. Stress is 0% OK r ' ..1 cad Ttubolt 0.5 Dia. X2,25 Ir _ - - . d. Pullout Capacity = 580 lbs. Shear Capacity =1190 lbs. No. Of Anchors = 1 per Base Plate (or avvroved aqua Anchor Stress a 8% OK NOTES: Design based on 2003 r zip code 981.88 w/ flay 1.0 & • 1.337. Design loading is 1,5001//level, , 0 0 c kt 07/23/2007 18:22 704 549 - 4946 Jul. 20 07 07:47a MATERIAL HANDLING ENGINEERING TEL : (909)869 - 0989 FAX: (909)869 . 0981 141 ATLANTIC STREET. POMONA. CA 9176E UNIVERSITY COURTYARD 9038530581 PROJECT TOR MEET NO. CALCULATED EY DATE PAGE 09/09 p. Abide Supply Center WA 98188 ibc Chase Equipment (Terry Y.) 8 / g m_ obi 7/19/2007 SEIZMIC MATERIAL HANDLING ENGINEERING EST. 1985 STORAGE RACKS STEEL SHELVING SEISMIC ANALYSIS ALASKA INDIANA OHIO DRIVE -IN RACKS MOVABLE SHELVING STRUCTURAL DESIGN ARIZONA KANSAS OKLAHOMA CANTILEVER RACKS STORAGE TANKS CRY APPROVALS CALIFORNIA MICHIGAN OREGON MEZZANINES MODULAR OFFICES STATE APPROVALS COLORADO MINNESOTA PENNSYLVANIA CONVEYORS GONDOLAS PRODUCT TESTING CONNECTICUT MISSOURI TEXAS CAROUSELS BOOKSTACKS FIELD INSPECTION GEORGIA MONTANA UTAH PUSHBACK RACKS FLOW RACKS SPECIAL FABRICATION IDAHO NEVADA VIRGINIA RACK BUILDINGS FOOTINGS PERMITTING SERVICES ILLINOIS NEW MEXICO WASHINGTON WISCONSIN SEISMIC ANALYSIS OF SELECTIVE IRACK FOR SEATTLE, WA 98188 JOB # 06 -0515A ReA CODEC so norwto MA1 121006 �►Lr of kwiia N FILE COPT Pe i t No. ALSIDE SUPPLY CENTER 161 ATLANTIC STREET • POMONA • CA al TAR • TCI • tono`neo -^O°° CAV•InflO f#S nnn. RECEIVED CITY OF TUKWILA APR 13 2 PERMIT CENTER to 132- E M IC MATERIAL HANDLING ENGINEERING TEL : (909)869 - 0989 FAX : (909)869 - 0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE ALSIDE SUPPLY CENTER CHASE EQUIPMENT CO. 2 MC 4/3/2006 TABLE OF CONTENTS & SCOPE PARAMETERS COMPONENTS & SPECIFICATIONS LOADS & DISTRIBUTION LONGITUDINAL ANALYSIS COLUMN BEAM BEAM TO COLUMN BRACING OVERTURNING BASE PLATE SLAB & SOIL TABLE OF CONTENTS THE STORAGE RACKS ARE PREFABRICATED AND ARE TO BE FIELD ASSEMBLED ONLY, WITHOUT ANY FIELD WELDING. 2 3 SCOPE: THIS ANALYSIS OF THE STORAGE SYSTEM IS TO DETERMINE ITS COMPLIANCE WITH THE APPROPRIATE BUILDING CODES WITH RESPECT TO STATIC AND SEISMIC FORCES. 4 12 13 14 15 17 18 19 20 21 rit MATERIAL HANDLING ENGINEERING TEL : (909)869 - 0989 FAX : (909)869 - 0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE ALSIDE SUPPLY CENTER CHASE EQUIPMENT CO. 3 MC 4/3/2006 THE STORAGE RACKS CONSIST OF SEVERAL BAYS, INTERCONNECTED IN ONE OR BOTH DIRECTIONS, WITH THE COLUMNS OF THE VERTICAL FRAMES BEING COMMON BETWEEN AND ADJACENT BAYS. THE ANALYSIS WILL FOCUS ON A TRIBUTARY BAY TO BE ANALYSED IN BOTH THE LONGITUDINAL AND TRANSVERSE DIRECTION. STABILITY IN THE LONGITUDINAL DIRECTION IS MAINTAINED BY THE BEAM TO COLUMN MOMENT RESISTING CONNECTIONS, WHILE BRACING ACTS IN THE TRANSVERSE DIRECTION. LEGEND 1. COLUMN 2. BEAM 3. BEAM TO COLUMN 4. BASE PLATE S. HORIZONTAL BRACING 6. DIAGONAL BRACING 7. BACK TO BACK CONNECTOR TRANSVERSE �TRIBUTARY AREA LONGITUDINAL *ACTUAL CONFIGURATION SHOWN ON COMPONENTS & SPECIFICATIONS SHEET COMPONENTS & SPECIFICATIONS : Time 194-9 2 WI =200016x. Y1 =54 in Y2 = 54 in Y3 = 54 in ANALYSIS PER SECTION 2208 OF THE 2003 LEVELS = 2 H1=90 in H2-84 in. PANELS = 3 IBC W �c-- Y3 I �` I I W2 =2000 lbs LIVE LOAD = 2000 lbs. 1-12 FRAME HEIGHT = 180 in. H }_ W H Y2 \ FRAME DEPTH = 48 in. BEAM LENGTH= 108 in. HI ZONE = D (Fa =1, Ss = 1.337) TYPE = SINGLE ROW 1 Yi L \ ._. •f I —A t --- I- L D - COLUMN BEAM @ Level 1 CONNECTOR @ Level l OK OK OK 3x3x14ga StepBeam 4 "x2.75 "xl6ga THREE PIN CONNECTOR Steel = 55000 psi Steel = 55000 psi Stress = 72% Stress =55% Max Static Capacity = 3667 lb. Stress = 55% COLUMN BACKER BEAM @ Level 2+ CONNECTOR @ Level 2+ OK OK StepBeam 4 "x2.75 "x 16ga THREE PIN CONNECTOR Max Static Capacity = 3667 lb. Stress = 30% Stress = 55% BRACING SLAB & SOIL HORIZONTAL OK DIAGONAL OK Slab = 5" X 2000 psi OK Soil Bearing Pressure = 1000 psf 11/2 X 1 X 14GA 1 1/2 X 1 X 14GA Slab Puncture Stress = 30% Stress = 16% Stress = 57% Slab Bending Stress = 24% BASE PI ,ATE ANCHORS OK Ramset/Redhead Trubolt 0.5 Dia. X 2.25 Min. Embd. OK 7 in X 5 in X 0.375 in Pullout Capacity = 580 lbs. Steel = 36000 psi Shear Capacity = 1190 lbs. MBase = 5833 in. lb. No. Of Anchors = 2 per Base Plate Stress = 42% Anchor Stress = 8% MATERIAL HANDLING ENGINEERING TEL : (909)869 0989 FAX : (909)869 0981 161 ATLANTIICTREET, POMON A 9176 PROJECT . FOR SHEET NO. CALCULATED BY DATE ALSIDE SUPPLY CENTER CHASE EQUIPMENT CO. 4 MC 4/31200 COMPONENTS & SPECIFICATIONS : Tyne 194-10 ANALYSIS PER SECTION 2208 OF THE 2003 IBC LEVELS = 2 HI =46 in. H2 =36 in. PANELS = 2 LIVE LOAD = 1500 lbs. FRAME HEIGHT = 120 in. H W2 W1=1500lbs. W2=1500 lbs. \ .. Y1 =5l in Y2 -51 in H2 T I W1 Y2 H \ FRAME DEPTH = 48 in. BEAM LENGTH= 51 in. ZONE = D (Fa =1, Ss =1337) TYPE = SINGLE ROW H1 Y1 l I I L T"" D -7 i COLUMN BEAM @ Level 1 CONNECTOR @ Level I OK 3x1- 5 /8xI3ga Steel = 55000 psi Stress =26% OK StepBeam 4'x2.75 "x16ga Steel = 55000 psi Max Static Capacity = 8206 lb. Stress =18% OK THREE PIN CONNECTOR Stress = 18% COLUMN BACKER BEAM @ Level 2+ CONNECTOR @ Level 2+ OK StepBeam 4'x2.75 "x16ga Max Static Capacity = 8206 lb. Stress =18% OK THREE PIN CONNECTOR Stress = 9% BRACING SLAB & SOIL HORIZONTAL OK 1 1/2 X I X 14GA Stress = 14% DIAGONAL OK 1 1/2 X1 X 14GA Stress = 44% Slab = 5" X 2000 psi OK Soil Bearing Pressure = 1000 psf Slab Puncture Stress =18% Slab Bending Stress = 8% BASE PLA TE ANCHORS OK 7 in X 5 in X .375 in Steel = 36000 psi MBase = 3852 in. lb. Stress = 29% Ramset/Redhead Trubok 0.5 Dia. X 225 Min. Embd. OK Pullout Capacity = 580 lbs. Shear Capacity = 1190 lbs. No. Of Anchors = 2 per Base Plate Anchor Stress = 3% € MATERIAL HANDLING ENGINEERING TEL : (909)869 - 0989 FAX : (909)869 - 0981 61 ATT ANTIC STREET. POMONA CA 9176 PROJECT FOR SHEET NO. CALCULATED BY DATE ALSIDE SUPPLY CENTER CHASE EQUIPMENT CO. 5 MC COMPONENTS & SPECIFICATIONS : Tyne 194-7 ANALYSIS PER. SECTION 2208 OF THE 2003 IBC LEVELS = 2 HI =60 in. H2 =6D in. PANELS = 2 LIVE LOAD = 3200 lbs. FRAME HEIGHT = 120 in. H W 2 WI —3200 lbs. W2= 3200lbs. Y1= 51 in Y2 =5lip - H2 W1 Y2 L H FRAME DEPTH = 48 in. BEAM LENGTH= 108 in. ZONE = D (Fa =1, Ss =1.337) TYPE = SINGLE ROW H1 Y1 I' COLUMN BEAM ® Level 1 CONNECTOR @ Level 1 OK 3xI 5/8x13ga Steel = 55000 psi Stress =86% OK StepBeam 4 "x2.75 "xl6ga Steel = 55000 psi Max Static Capacity = 3667 lb. Stress = 87% OK THREE PIN CONNECTOR Stress = 69% COLUMN BACKER BEAM @ Level 2+ CONNECTOR @ Level 2+ OK StepBeam 4 "x2.75 "xl6ga Max Static Capacity = 3667 lb. Stress = 87% OK THREE PIN CONNECTOR Stress = 32% BRACING SW & SOIL HORIZONTAL OK 1 1/2 X 1 X 14GA Stress = 29% DIAGONAL OK 1 1/2 X 1 X 14GA Stress = 90% Slab = 5" X 2000 psi OK Soil Bearing Pressure = 1000 psf Slab Puncture Stress = 41% Slab Bending Stress = 43% BASE PLATE ANCHORS OK 7 in X 5 in X 0.375 in Steel = 36000 psi MBase = 5833 in. lb. Stress = 50% Ramset/Redhead Trubolt 0.5 Dia. X 2.25 Min. Embd. OK Pullout Capacity = 580 lbs. Shear Capacity = 1190 lbs. No. Of Anchors = 2 per Base Plate Anchor Stress = 8% MATERIAL HANDLING ENGINEERING TEL : (909)869 - 0989 FAX : (909)869 - 0981 61 ATLANTIC STREET. PO ON CA 9176 PROJECT FOR SHEET NO. CALCULATED BY DATE ALSIDE SUPPLY CENTER CHASE EQUIPMENT CO. 6 MC 4/3/2006 COMPONENTS & SPECIFICATIONS : Type 194-3 ANALYSIS PER SECTION 2208 OF THE 2003 IBC LEVELS = HI =46 in. H2 =36 in. PANELS =2 H3 =38 in. LIVE LOAD = 1500lbs. FRAME HEIGHT = 120 in. FRAME DEPTH = 48 in. BEAM LENGTH= 51 in. ZONE = D (Fa =1, Ss =1337) TYPE = SINGLE ROW \ W9 W1 =1500 Ibs. W2 =1500lbs. W3 =15001bs. Y1 =51 in Y2 =51 in H3 H H2 H1 T \ W2 Y2 W 1 H Yi \ COLUMN BEAM @ Level 1 CONNECTOR @ Level 1 OK 3x1- 5/8x13ga Steel = 55000 psi Stress =40% OK StepBeam 4 "x2.75 "xl6ga Steel = 55000 psi Max Static Capacity = 8206 lb. Stress = 18% OK THREE PIN CONNECTOR Stress = 28% COLUMN BACKER BEAM @ Level 2+ CONNECTOR @ Level 2+ OK StepBeam 4 "x2.75 "xl6ga Max Static Capacity = 8206 lb. Stress = 18% OK THREE PIN CONNECTOR Stress = 20% BRACING SLAB & SOIL HORIZONTAL OK 1 1/2 X 1 X 14GA Stress = 21% DIAGONAL OK 1 1/2 X1 X 14GA Stress = 66% Slab = 5" X 2000 psi OK Soil Bearing Pressure = 1000 psf Slab Puncture Stress = 29 Slab Bending Stress = 23% BASE P1,ATF ANCHORS OK 7 in X 5 in X .375 in Steel = 36000 psi MBase = 5778 in. lb. Stress = 43% Ramset/Redhead Trubolt 0.5 Dia. X 2.25 Min. Embd. OK Pullout Capacity = 580lbs. Shear Capacity = 1190 lbs. No. Of Anchors = 2 per Base Plate Anchor Stress = 5% r $Ea C MATERIAL HANDLING ENGINEERING TEL : (909)869 - 0989 FAX : (909)869 - 0981 CSTREET P N CA9PL PROJECT FOR SHEET NO. CALCULATED BY DATE ALSIDE SUPPLY CENTER CHASE EQUIPMENT CO. 7 MC 413/2006 COMPONENTS & SPECIFICATIONS : Tvoe 194-8 ANALYSIS PER SECTION 2208 OF THE 2003 IBC LEVELS = H = 20 in. H2 =20 in. PANELS = H3 =30 in. H4 =30 in. LIVE LOAD =1500 lbs. FRAME HEIGHT = 120 in. W4 - WI =1500 lbs. W2 =1500 lbs. W3— ISOOlbs. W4 =1500 lbs. YI = Sl in Y2 = 51 in H4 H3 H I W 3 Y2 T W2 4. H FRAME DEPTH = 48 in. BEAM LENGTH= 108 in. ZONE = D (Fa =1, Ss = 1.337) TYPE = SINGLE ROW H2 I Wi Y1 H1 `l \ \ 4 --- L — + D — 11' COLUMN BEAM @ Level 1 CONNECTOR @ Level 1 OK 3x1- 5 /8xl3ga Steel = 55000 psi Stress =53% OK StepBeam 4 "x2.75 "xl6ga Steel = 55000 psi Max Static Capacity = 3667 lb. Stress = 41% OK THREE PIN CONNECTOR Stress = 33% COLUMN BACKER BEAM @ Level 2+ CONNECTOR @ Level 2+ OK StepBeam 4 "x2.75 "xl6ga Max Static Capacity = 3667 lb. Stress = 41% OK THREE PIN CONNECTOR Stress = 23% BRACING SLAB & SOIL HORIZONTAL OK 1 1/2 X 1 X 14GA Stress = 28% DIAGONAL OK 1 1/2 X 1 X 14GA Stress = 89% Slab = 5" X 2000 psi OK Soil Bearing Pressure = 1000 psf Slab Puncture Stress = 39% Slab Bending Stress = 39% BASE PLATE ANCHORS OK 7 in X 5 in X 0.375 in Steel = 36000 psi MBase = 5833 in. lb. Stress = 49% Ramset/Redhead Ttubolt 0.5 Dia. X 2.25 Min. Embd. OK Pullout Capacity = 580 lbs. Shear Capacity = 1190 lbs. No. Of Anchors = 2 per Base Plate Anchor Stress = 8% _ SEIL� ZM�C MATERIAL HANDLING ENGINEERING TEL : (909)869 - 0989 FAX : (909)869 - 0981 161 ATLANTI STRE ET. POMONA. CA 9176 PROJECT FOR SHEET NO. CALCULATED BY DATE ALSIDE SUPPLY CENTER CHASE EQUIPMENT CO. 8 MC 4/3/2006 COMPONENTS & SPECIFICATIONS ; Time 194-6 ANALYSIS PER SECTION 2208 OF THE 2003 IBC \ LEVELS = 4 H1 =30 in. H2 =30 in. PANELS = 2 H3 =30 in. 114 =30 in. LIVE LOAD = 1500 lbs. FRAME HEIGHT = 120 in. W4 WI= 1500lbs. W2=1500 lbs. W3= 1500lbs. W4 —1500 lbs. Y1 =51 in Y2 = 51 in H4 W3 Y2 H3 H W2 H N FRAME DEPTH = 48 in. BEAM LENGTH= 51 M. H2 Wi Y1 ZONE = D (Fa =1, Ss = 1.337) TYPE = SINGLE ROW '.. I H1 Ni. 4-- L --4 D COLUMN BEAM @ Level 1 CONNECTOR @ Level 1 OK 3x1- 5 /8x13ga Steel = 55000 psi Stress =43% OK StepBeam 4 "x2.75 "xl6ga Steel = 55000 psi Max Static Capacity = 8206 lb. Stress =18% OK THREE PIN CONNECTOR Stress = 28% COLUMN BACKER BEAM @ Level 2+ CONNECTOR @ Level 2+ OK StepBeam 4 "x2.75 "xl6ga Max Static Capacity = 8206 lb. Stress =18% OK THREE PIN CONNECTOR Stress = 25% BRACING SLAB & SOIL HORIZONTAL OK 1 1/2 X I X 14GA Stress = 28% DIAGONAL OK 11/2 XI X I4GA Stress = 89% Slab = 5" X 2000 psi OK Soil Bearing Pressure = 1000 psf Slab Puncture Stress = 39% Slab Bending Stress = 39% BASF. PI ATE ANCHORS OK 7 in X 5 in X .375 in Steel = 36000 psi MBase = 4902 in. lb. Stress = 45% RamseURedhead Trubolt 0.5 Dia. X 2.25 Min. Embd. OK Pullout Capacity = 580 lbs. Shear Capacity = 1190 lbs. No. Of Anchors = 2 per Base Plate Anchor Stress = 8% SEiLS ZMIC MATERIAL HANDLING ENGINEERING TEL : (909)869 - 0989 FAX : (909)869 - 0981 PROJECT FOR SHEET NO. CALCULATED BY DATE ALSIDE SUPPLY CENTER CHASE EQUIPMENT CO. 9 MC COMPONENTS & SPECIFICATIONS ' : Tvne 194-12 ANALYSIS PER SECTION 2208 OF THE 2003 IBC LEVELS =3 HI =40 in. H2 =40 in. PANELS = 2 H3 n.40 in. LIVE LOAD = 2000 lbs. FRAME HEIGHT = 120 in. FRAME DEPTH = 48 in. BEAM LENGTH= 108 in. ZONE = D (Fa =1, Ss = 1337) TYPE = SINGLE ROW W 3 - WI .n2000 lbs. W2 = 2000lbs. W3 =2000 lbs. - Yl =5]in Y2 = 51 in H3 w 2 Y2 H H2 H1 \ w 1 H Y1 \ COLUMN BEAM ® Level 1 CONNECTOR ® Level 1 OK 3x1 5/8x13ga Steel = 55000 psi Stress =51% OK StepBeam4 "x2.75 "x16ga Steel = 55000 psi Max Static Capacity = 3667 lb. Stress = 55% OK THREE PIN CONNECTOR Stress = 41% COLUMN BACKER BEAM ® Level 2+ CONNECTOR @ Level 2+ OK StepBeam 4 "x2.75 "xl6ga Max Static Capacity = 3667 lb. Stress = 55% OK THREE PIN CONNECTOR Stress = 32% BRACING SLAB & SOIL HORIZONTAL OK 1 1/2 X I X 14GA Stress = 28% DIAGONAL OK 1 1/2 X 1 X 14GA Stress = 87% Slab = 5" X 2000 psi OK Soil Bearing Pressure = 1000 psf Slab Puncture Stress = 38% Slab Bending Stress = 39% BASK PL ANCHORS OK 7 in X 5 in X 0.375 in Steel = 36000 psi MEase = 5833 in. lb. Stress = 49% Ramset/Redhead Trubolt 0.5 Dia. X 2.25 Min. Embd. OK Pullout Capacity = 580 lbs. Shear Capacity = 1190 lbs. No. Of Anchors = 2 per Base Plate Anchor Stress = 8% SELLS ZIIC MATERIAL HANDLING ENGINEERING TEL : (909)869 - 0989 FAX : (909)869 - 0981 161 ATLANTIC STREET. POMONA. CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE ALSIDE SUPPLY CENTER CHASE EQUIPMENT CO. 10 MC 4/3/2006 COMPONENTS & SPECIFICATIONS : Tyne 194-1 ANALYSIS PER SECTION 2208 OF THE 2003 IBC LEVELS =3 H1=62 in. H2 =28 in. PANELS = H3 =30 in. LIVE LOAD = 1500 lbs. FRAME HEIGHT = 120 in. W 3 W1= 15001bs. W2 =1500 lbs. W3 =1500lbs. H N Y1 =51 in Y2 = 51 in H3 H T \ I W2 Y2 W I H2 FRAME DEPTH = 48 in. BEAM LENGTH= 51 in. - ZONE = D (Fa =1, Ss =1.337) H1 TYPE - SINGLE ROW Y1 N \ L \ II4- '' I' L 'I D '�( COLUMN BEAM @ Level 1 CONNECTOR @ Level 1 OK 3x1- 5/8x13ga Steel = 55000 psi Stress =58% OK StepBeam 4"x2.75"xl6ga Steel = 55000 psi Max Static Capacity = 8206 lb. Stress = 18% OK THREE PIN CONNECTOR Stress = 36% COLUMN BACKER BEAM @ Level 2+ CONNECTOR @ Level 2+ OK StepBeam 4 "x2.75 "x l6ga Max Static Capacity = 8206 lb. Stress = 18% OK THREE PIN CONNECTOR Stress =15% BRACING SLAB & SOIL HORIZONTAL OK 11/2 X 1 X 14GA Stress = 21% DIAGONAL OK 1 1/2 X 1 X 14GA Stress = 66% Slab = 5" X 2000 psi OK Soil Bearing Pressure = 1000 psf Slab Puncture Stress = 30% Slab Bending Stress = 24% RASE PLATE ANCHORS OK 7 in X 5 in X 0.375 in Steel = 36000 psi MBase = 5833 in. lb. Stress = 44% Ramset/Redhead Trubolt 0.5 Dia. X 2.25 Min. Embd. OK Pullout Capacity = 580 lbs. Shear Capacity = 1190 lbs. No. Of Anchors = 2 per Base Plate Anchor Stress = 5% MATERIAL HANDLING ENGINEERING TEL : (909)869 - 0989 FAX : (909)869 - 0981 6LATLANTIC STREET. POMONA. CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE ALSIDE SUPPLY CENTER CHASE EQUIPMENT CO. 11 MC 4/3/2006 LATERAL FORCE DISTRIBUTION h IN LEVEL WEIGHT LB HEIGHT IN W X H LB -IN Fi (LONG) Fi (TRANS) 90 1 2,000 90 180,000 156 156 84 2 2,000 174 348,000 301 301 - 3 - - - - - - 4 - - - - - 5 - - - - - - 6 - - - - - - 7 - - - - - - 8 - - - - - - 9 - - - - - - 1 0 - - - - - - 11 - - - - - - 12 - - - - - - 13 - - - - - 174 ] E - 528,000 456 LB 456 LB MATERIAL HANDLING ENGINEERING TEL: (909) 869 -0989 • FAX: (909) 869 -0981 161 ATLANTIC AVENUE • POMONA, CA 91768 PROJECT ALSIDE SUPPLY CENTER FOR CHASE EQUIPMENT CO. SHEET NO. 12 CALCULATED BY MC DATE 4/3/2006 LOADS & DISTRIBUTION: Type 194-9 LIVE LOAD PER SHELF (BASED ON CLIENT SUPPLIED DATA) = wLL DEAD LOAD PER SHELF = wDL SEISMIC BASE SHEAR BASED ON SECTION 2208 OF THE 2003 IBC WHERE LATERAL FORCES ARE IN ACCORDANCE WITH SECTION 2.7.3 OF THE 1997 RMI & ASCE 7 -02: V = Cs • Ip * Wtotal AND Cs = 2.5 *Ca/R AND Wtotal = (0.667wLL + wDL) SOIL PROFILE TYPE = D Sos = 2 /3 *Fa *Ss AND Fa= 1, Ss =1.337 Ca = S <= PER SECTION 9.14.6.3 ASCE 7 -02 = 0.357 1p = 1.00 Rw (LONGITUDINAL) = 4 Rw (TRANSVERSE) = 4 wDL = 100 LB HEIGHT= 1801N WIDTH= 108 IN DEPTH= 48 IN LONGITUDINAL DIRECTION: Vlong = [2.5 *0.357* 1 *(0.667 *4000 LB +200 LB) /4]/1.4 = 456 LB Fi= V Whi/EWh TRANSVERSE DIRECTION: Vtrans = (2.50.3571(0.6674000 LB +200 LB) /4]/1.4 = 456 LB Fi= V Whi/EWh TOTAL FRAME LOAD = 4200 LB LEVELS h, f AXIAL LOAD MOMENT Mconn 1 2 88 84 78 150 2,100 1,050 14,231 6,300 12,130 5,015 Etc " MATERIAL HANDLING ENGINEERING TEL : (909)869 - 0989 FAX : (909)869 - 0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE ALSIDE SUPPLY CENTER CHASE EQUIPMENT CO. 13 MC 4/3/2006 LONGITUDINAL ANALYSIS: Type 194 -9 THE ANALYSIS IS BASED ON THE PORTAL METHOD, WITH THE POINT OF CONTRA FLEXURE OF THE COLUMNS ASSUMED AT MID- HEIGHT BETWEEN BEAMS, EXCEPT FOR THE LOWEST PORTION, WHERE THE BASE PLATE PROVIDES ONLY PARTIAL FIXITY, THE CONTRA FLEXURE IS ASSUMED TO OCCUR CLOSER TO THE BASE. (OR AT THE BASE FOR PINNED CONDITION, WHERE THE BASE PLATE CANNOT CARRY MOMENT). MUOFer + M = M cnnn'R' + M Corm'L! M C 'R' ` M Conn'L' Mconn • 2 = MURRer + MLower ( Mur + M er 1 — 2 ) + MLncs Vcol = V 2 s MBaae = 5833 in/lb = 228 lbs SAMPLE CALC. Mt_t = (Vcor ' h T ) — MBase = (228 Ibs X 88 in) - 5833 in/lb = 14,231 in/lb MEnj+ = 1865 in/lb Mn -n FRONT ELEVATION €IC " MATERIAL HANDLING ENGINEERING TEL : (909)869 - 0989 FAX : (909)869.0981 161 ATLANTIC STREET. POMONA. CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE ALSIDE SUPPLY CENTER CHASE EQUIPMENT CO. 14 MC 4/3/2006 COLUMN ANALYSIS : Type 194 -9 ANALYZED PER AISI AND THE 2003 IBC. SECTION PROPERTIES BASED ON THE EFFECTIVE SECTION. P = 2100 lbs M = 14231 in/lb K • L R K Y L Y — IX 54in / I.08in R = 50 Axio! 112E Fe (k-1/ Max� Pn = Aeff • F„ P =ac P P F exure 1.2 X 88in / 1.326in 79.6 Since : P P a 0.15 a Myeild = M =S • F = Max = M S2f Pcr = n (KI)Max _ / 1 1 1- CIc P x - ( Pcr) 45.9 KSI = 24773 lbs / 1.92 = 0.16 = 41415 /1.67 K Max R 79.6 F 28 KS( 2 Since: F >F F = 55 KSI X [l - 55 KSI / (4 X 45.90714KS1)j F „ =F —' J ll 4 . F J = 38.5 KSI = 0.643 in ^2 X 38.5 KSI = 24773 lbs 12902 lbs Check :P + ' 51.33 P Max 0.753 In ^3 X 55000 PSI = 41415 in/lb 24799 in/lb (3.14159) ^2 X 29500 KSI / (105.6in.) ^2 = 29503 lbs _ (11(I - (1.92 X 21001b / 29503 1b)))/`-1 = 0.86 (2100 lb / 12902 lb) + (0.85 X 14231 in/lb / 24799 in/lb X 0.86) = 0.73 < 1.33 (55 %) -01 14-- C SECTION PROPERTIES A : 3 i B : 3 in C t : 0.075 in Aeff : 0.643 in” Ix : 1.13 in ^4 Sx : 0.753 in^3 Rx :1.326 in Iy : 0.7492 in" Sy : 0.493 in ^ 3 Ry : 1.08 in Kx : 1.2 Lx : 88 in Ky :1 Ly : 54 in Fy : 55 KS1 E : 29500 KSI S2c: 1.92 of : 1.67 Cmx : 0.85 Cb : I MATERIAL HANDLING ENGINEERING TEL : (909)869 - 0989 FAX : (909)869 - 0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE ALSIDE SUPPLY CENTER CHASE EQUIPMENT CO. 15 MC 4/3/2006 BEAM ANALYSIS : Type 194 -9 BEAM TO COLUMN CONNECTIONS PROVIDE ADEQUATE MOMENT CAPACITY TO STABLIZE THE SYSTEM, ALTHOUGH IT DOES NOT PROVIDE FULL FIXITY. THUS, THE BEAMS WILL BE ANALYSED ASSUMING PARTIAL END FIXITY. FOR THE COMPUTATION OF BEAM TO COLUMN MOMENT CAPACITY, THE PARTIAL END FIXITY MOMENT OF THE BEAM WILL BE ADDED TO THE LONGITUDINAL FRAME MOMENT FOR THE ANALYSIS OF THE EFFECTIVE MOMENT FOR PARTIALLY FIXED BEAM For a simply supported beam, the max moment at the center is given by WE ' /s An assumption of partial fixity will decrease this maximum moment by the following method. Percentage of End Fixity = 20% MCenter = MCenter(Simple ends) - 6 *MCenter(Fixed ends) W1 /8 —(O •N? /12)= 0.108•W1 Reduction Coefficient (i = 0.108/0.125 = 0.867 Mcenrer = / .W1 =0.867 .W12/8 MEnds =ft • M ir (FixedEnds) = W1 0.2 = 0.0167 .W1 EFFECTIVE DEFLECTION FOR PARTIALLY FIXED BEAM For a simply supported beam, the max deflection at the center is given byswt' /384 El . An assumption of partial fixity will decrease this maximum deflection by the following method. LiveLoad llvl = 2000 lbs 5W1 liMar 384• DeadLoad /lvl =41b /ft X 2 X (108/12 = Mcenrer = 0.108* 3)7 M Ends = 0.0167* Wl F = 0.6 • Fy 33000 PSI FB = 33000 PSI =12121 in/lb = 1865 in/lb 72 lbs 4 = 0.2 Mends Mcerter(senpie) Meaner Pomp . .lIlaulll hIIlIIIIIlillun�e. .I �II�P' �11I., - L ,, L jeVALREAM FROVTVEW ALLOWABLE AND ACTUA BENDING MOMENT AT EACH LEVEL * Fe M Armw,se mrc = S ■ F, +1.33 M Se . rc = M c m Ms�;e =W12/8 M Allow,Static = Sx AI impact = Msrm,e • 1.125 Level M S a ;c impact M A ._ Ms„;�� MAllow,Seisnic Result 1 2 12121 12121 13636 13636 24618 24618 12130 5015 32824 32824 GOOD GOOD 1 � SEIZM C MATERIAL HANDLING ENGINEERING TEL : (909)869 - 0989 FAX : (909)869 - 0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE ALSIDE SUPPLY CENTER CHASE EQUIPMENT CO. 16 MC 4/3/2006 BEAM ANALYSIS : Type 194 -9 MAXIMUM STATIC LOAD PER LEVEL DEPENDS ON: 1. MAXIMUM MOMENT CAPACITY Fb = M /S x • ( 2 /8) FBE — S s FBEff • 16 •S x Max.Weight /1v1= a / = ((33000 X 16 X 0.746) / (0.867 X 108)) X 0.875 = 3667 Ibs/Ivl 2. MAXIMUM ALLOWABLE DEFLECTION know = L/180 = 0.6 In 5Wl" __ A 384. E•I Max.Weight / Ivl = 384 • E • Ix • A All' L3 5 -40 = ((384 X 29000000 X 1.589 X 0.6) / (5 - (4 X 0.2))) X 108A3 = 4013 lbs/Ivl MAXIMUM ALLOWABLE LIVE LOAD PER LEVEL = 36671bs/Ivl j = 1.589 inA4 ,S = 0.746 inA3 F,, =55000 PSI a(impactCoefficient) = 0.875 Q =0.867 B = 0.2 L(Length) = 108 in Step = 1.625 in Top Width =1.875 in BeamStress = 55% L = 108 in Beam Thickness = 0.0598 i BeamDepth = 4 in Bottom Width = 2.75 in SEIL� ZMIC MATERIAL HANDLING ENGINEERING TEL : (909)869 0989 FAX : (909)869 - 0981 161 ATLANTIC STREET, POMONA, CA 91768 BEAM TO COLUMN ANALYSIS : T i e 194 -9 • To Cs ` •N APACI DEPE DSO HE 1. SHEAR CAPACITY OF PIN PinDiameter =0.4381n. F = 55000 PSI Asuear = Diameter • 4 PShear = 0.4 •Ashear = 0.4 X 55000 X 0.1507 in^ = 2. BEARING CAPACITY OF PIN ColumnThickness = 0.075 F = 65000PSI S2 = 2.22 a = 2.22 Bearing 0.1507 in ^2 = a • F • Dia. • Col.Thickness /S2 3. MOMENT CAPACITY OF BRACKET EdgeDist . =1.0 In. PinSpacing = 2 In F = 55000 PSI C P, +P +P T = 0.179 In. S cut' = 0.127/n 16880in lb > 12130m -lb WING PARAMETERS: = P + P (2.5/4.5)+ P (5/4.5) PROJECT ALSIDE SUPPLY CENTER FOR CHASE EQUIPMENT CO. SHEET NO. 17 CALCULATED BY MC DATE 4/3/2006 3315 lbs P1 P3 r = 2.22 X 65000 X 0.438 X 0.075 / 2.22 = 2135 lbs M capanry = S cny • F Bending = 0.127 In ^3 X .66 X Fy 4610 in -lb C • d = Mc = 1.667 P, • d d = EdgeDist/2 = 0.5 Pap = ,010,/( • = 4610 /(1.667X0.5)= 5531 lbs MINIMUM VALUE OF P1 GOVERNS • = 2135 M ann -Allow = [P, *4.5] +[P, *(2.5/4.5 *2.5] +[P, *(5/4.5) *.5] *1.33 OK = PIX1.667 3" : AT LEVEL 1 /2' a• 1-3/8^ S MATERIAL HANDLING ENGINEERING TEL : (909)869 - 0989 FAX : (909)869 - 0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE ALSIDE SUPPLY CENTER CHASE EQUIPMENT CO. 18 MC 4/3/2006 TRANSVERSE ANALYSIS: BRACING: Type 194 -9 IT IS ASSUMED THAT THE LOWER PANEL RESISTS THE FRAME SHEAR IN TENSION AND COMPRESSION. IF HORIZONTAL AND DIAGONAL MEMBERS ARE THE SAME, ANALYSIS WILL BE DONE ON THE DIAGONAL MEMBER AS IT WILL GOVERN. DIAGONAL BRACING : COMPRESSION MEMBER Ldiag = V(L — 6) + (D —(2 • BCoI )) = 63.8" Vdiag = Vtrans • LDiag k•1 rMin II Fe ( k � rMin F 2 F 2v F„ — Fe S2c =1.92 P = P fth Brace Stress d VDiag P a = 693 lbs (1 X 63.7809)/(0.316) = 201.8 In = 7025.7 PSI = 27500 = 7025.7 PSI P„ = Area • F„ = 17561bs = 915 lbs = 0.76 < 1.33 (57 %) t 1 C V $OF ELEVATION Panel Height (L) _ Panel Depth (D) _ Column Depth (B) = Clear Depth (d) = (D - 2•B) = 54 In 48 In 3 In 42 SEIL ZMIC MATERIAL HANDLING ENGINEERING TEL : (909)869 - 0989 FAX : (909)869 - 0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO, CALCULATED BY DATE ALSIDE SUPPLY CENTER CHASE EQUIPMENT CO. 19 MC 4/3/2006 OVERTURNING ANALYSIS : Tyne 194-9 FULLY LOADED Total Shear = 456 lbs M = V Mow = 456 X 146 X 1.15 M„ = E(W +.85wDL).d /2 M„ 1 ( M ow —M st � 1tin = d _ (4000 +(.85 X 200)) X 48/2 TOP SHELF LOADED Shear = 244 lbs M V op • Ht • 1.15 Mow = 244X 174X 1.15 M = E(W +wDL).d /2 M = (2000 + (.85 X 200)) X 48 /2 _ l(Movt — Mst) PUPUi d = 76562 in/lb = 100080 in/lb (76562 - 100080) / 48 - 490 lbs. Puplift <= 0 No Up Lift = 48836 in/lb = 52080 in/lb = (48836 - 52080) / 48 _ -68 lbs. Puplift<=0 No up Lift ANCHORS No. of Anchors : 2 Pull Out Capacity : 580 Lbs. Shear Capacity : 1190 Lbs. COMBINED STRESS Fully Loaded = (0 / 580 X 2)» ((456 /2)/(1190 X 2)) = 0.02 Top Shelf Loaded = (0 / (580 X 2))+ ((244 /2)/(1190 X 2)) = 0.01 USE 2 Ramset/Redhead Trubolt 0.5 Din. X 2.25 Min. Embd. Anchors per BasePlate. Pup1ft w I Fs At F 3 trit F2 CROSS AISLE ELEVATION F4 F5 MATERIAL HANDLING ENGINEERING TEL : (909)869 - 0989 FAX : (909)869 - 0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE ALSIDE SUPPLY CENTER CHASE EQUIPMENT CO. 20 MC 4/3/2006 BASE PLATE ANALYSIS : Type 194 - 9 THE BASE PLATE WILL BE ANALYZED WITH THE RECTANGULAR STRESS RESULTING FROM THE VERTICAL LOAD P, COMBINED WITH THE TRIANGULAR STRESSES RESULTING FROM THE MOMENT Mb (IF ANY). THERE ARE 3 CRITERIA IN DETERMINING Mb. THEY ARE 1. MOMENT CAPACITY OF THE BASE PLATE, 2. MOMENT CAPACITY OF THE ANCHOR BOLTS, AND 3. Vcol'h/2 (FULL FIXITY). Mb IS THAT SMALLEST VALUE OBTAINED FROM THE 3 CRITERIA ABOVE. Pcot = 2100 lbs M = 5833 in/lb P P cor A D•B (� M b J6 = D•B216 { 2 b {{ fb2 = B Jb Jbl — i — fb2 1•t2 S Bas e = 1. 6 F ((Ba4E = .75F y -1.33 Jb M b F D S Base • F ease ANCHOR TENSION T _ M Base P Cot • b d n • d 60 PSI = 142.8 PSI = 81.63 PSI = 61.22 PSI wb, 6, Mb = 2 = ' a + bl +.6742] 1 yf b = 351.28 in/lb = 0.02 in /cb = 36000 PSI Base Plate Width (B) Base Plate Depth (D) Base Plate Thickness (t) = 0.42 <= 1 OK No. of Anchors Resisting Tension (n) = 1 EMo T• d2= M Bae — ( = 0 NEGATIVE, THEREFORE NO TENSION = 7 in = Sin = 0.375 in b bl Fv (base) 4 = 3 in = 2 in = 36000 PSI I V I t b1 b — bl T 4_ Danchort SEiL IC " MATERIAL HANDLING ENGINEERING TEL : (909)869 - 0989 FAX : (909)869 - 0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE ALSIDE SUPPLY CENTER CHASE EQUIPMENT CO. 21 MC 4/3/2006 SLAB AND SOIL : Type 194 -9 THE SLAB WILL BE CHECKED FOR PUNCTURE STRESS. IF NO PUNCTURE OCCURS, IT WILL BE ASSUMED TO DISTRIBUTE THE LOAD OVER A LARGER AREA OF SOIL AND WILL ACT AS A FOOTING. PUNCTURE Pswuc = 2100 lbs P = (1.2.P +1.0•(M 0 ,Id)) * = F = 2• fc l l A,,,,, =KB +2 I +(W +- I]•2•t J v Pm � 111 l ))) Fu A puncl • F punc, SLAB TENSION P .144 1.33. f soi, L = 4soN B= B•W +t b— L —B 2 wb „•b Acne= 2 _ 144.2 1• Sconc = 6 F ro= = 5017: f b = M Conn Fb S conc ' F conc OK M _ = 0.3 76562.4 in-lb 4527 lbs 89.44 PSI 170 sq. in. = 490 sq. in. = 22.14 in = 10.92 in = 5.61 in = 145 in-lb = 4.17 cb. in. = 145.34 PSI = 0.24 * (EQ 16 -19) SEC. 1605.4 P B = 7 i W = 5 in Frame Depth d = 48 in CONCRETE fb t 0 = 2000 PSI = 5 in = 0.65 SOIL (soil = 1000 PSF ASSOCIATED MATERIALS® C O N P OR A i E 0 ATTENTION: AL METZLER, SR. FIRE INSPECTOR TUKWILA FIRE DEPARTMENT Fat cop Permit N Inspector Metzler' ►� r Per your request in your e-mail to me dated 3/22 attached is the, specificatigmsheets for.lhe and insulation products that we will be inventorying in the space: at 6701 S_ Glacier Street Additionally, below, please find the other information•that you requested. • " Warehouse ceiling height: 25'1" to the underside of the roof deck and 22' cfeai:'iinder•the glu -lam. . .... Product Storage: If you have any questions, please don't hesitate to contact me at my office 330 - 922 - 7600. Regards, Refer to the rack elevation blue jrint -that shows what inp.terial, and how the material will be stored in the racks and l ori fopf the racks. The top deck of the racks will be at 10' and any product that is stored at this 10' level will either be boxed vinyl material, or metal rolled coil on a 4' x 4' pallet at a maximum per pallet height of approx. 4'. We may also stack metal ladders and stages at this 1111' level as well not to exceed approx. 3'. All palletized insulation products will be floor - stacked, one pallet high. The height of these pallets range from 3' to 8'. MB) FOR ,Q CODE COMPLIANCE �J soeonlicp Ryan George MAC 12 2006 Real Estate and Facilities Project Man er Associated Materials Incorporated yOfTukwita RIITLnTNC MINIM 3773 State Road / PO Box 2010 / Akron, Ohio 44309 1 330.929.1811 r A is ide / Gentek / Revere / Alpine / Preservation / Ultra Guard RECEIVED CITY OF TUKWILA APR 1 3 2136 PERMIT CENTEN d ekliSda s First On America's Ho December 9, 2005 RE: Alside Vinyl Siding, Soffit and Accessories To Whom It May Concern: The data listed below is a typical Alside siding compound. This information was obtained from Alside Research and Development office. PVC Resin 80 -90% Acrylic Processing Aids 0 -3% Acrylic Impact Modifier 3 -6% PVC Tin Stabilizer 1 -3% Calcium Stearate Fusion Promoter 0 -3% Lubricants (Waxes, Etc.) 1-4% Titanium Dioxide 8 -10% Sincerely, Nicholas D. Thompson Technical Representative 3773 STATE ROAD • P.O. BOX 2010 • AKRON, OHIO 44309 • (330) 929 -1811 yr RECYCLED alside Home Siding - Product Specification and Profiler Page 1 of 5 SBZ1 PSI& ESI 0 SBCCI PUBLIC SAFETY TESTING AND EVALUATIO INC. 900 Montclair Road, Suite A; Birmingham, Alabama 35213 -1206 a Participating Member of the NES, Inc. Evaluation Reports are the opinion of the Committee on Evaluation, based on the findings, and do not constitute or imply an approval or acceptance by any local community. The Committee, in review of the data submitted, finds that in their opinion the product, material, system, or method of construction specifically identified in this report conforms with or is a suitable alternate to that specified in the Standard and International Codes, SUBJECT TO THE LIMITATIONS IN THIS REPORT. The Committee on Evaluation has reviewed the data submitted for compliance with the Standard Building Code© and the International One and Two Family Dwelling Code and submits to the Building Official or other authority having jurisdiction the following report. The Committee on Evaluation, SBCCI PST & ES1 and its staff are not responsible for any errors or omissions to any documents, calculations, drawings, specifications, tests or summaries prepared and submitted by the design professional or preparer of record that are listed in the Substantiating Data Section of this report. Portions of this report were previously included in Evaluation Reports #93148, #9 632, #9632A, and #96326. Copyrighted 2000 SBCCI PSI & ESI REPORT NO.: 9632C EXPIRES: See current SBCCI PSI & ESI EVALUATION REPORT LISTING CATEGORY: EXTERIOR FINISHES SUBMITTED BY: ALSIDE DIVISION OF ASSOCIATED MATERIALS, INC. 3773 STATE ROAD CUYAHOGA FALLS, OHIO 44223 REVIEWED FOR CODE COMPLIANCE soeonuco MAY 12 2006 Tukwila CA Y �� �tt t%tuT CtfM C'tS 1. PRODUCT TRADE NAME Alside Premium Vinyl Siding 2. SCOPE OF EVALUATION Weather and wind resistance 3. USES Alside Premium Vinyl Siding is used as an exterior siding and soffit material for Type VI construction. rrow RECEIVED CITY OF TUKWILA APR 13 2006 PERMIT CENTER pup-- 132 http: / /intranet. alside .com /tssg/ArchitecturalSpecs /reports /sbcci.htm 3/23/2006 alside Home Siding - Product Specification and Profiler Page 2 of 5 4. DESCRIPTION Alside Premium Vinyl Siding is manufactured from solid, rigid polyvinyl chloride (PVC) compound, complying with the requirements of ASTM D 3679 -91a. The horizontal and vertical lap vinyl sidings are for use as an exterior finish. The minimum thickness of all siding and soffit styles is 0.035 inches (0.9 mm). Alside Premium Vinyl Siding is available in a variety of colors and wood -grain textures with matching inside and outside corner posts, trim, and moldings. A horizontal soffit in a matching color is also available. Soffit material is available in a vented design. Refer to Table 1 for siding /soffit characteristics and profiles for each siding /soffit style. 5. INSTALLATION 5.1 General All the siding styles are designed to be installed over solid sheathing (structural or non - structural) with furring being used on uneven walls or masonry surfaces. The siding is hung with aluminum or other corrosion resistant fasteners located in the middle of the siding's nail slot and shall not be drawn tight. The manufacturer's published installation instructions shall be strictly adhered to and copies available at all times on the jobsite during installation. 5.2 WInd Resistance Assemblies Alside Premium Vinyl Siding has an allowable negative wind loading of 30 psf (1436 Pa) when applied as follows: Nominal 2" x 4" (51 mm x 102 mm) wood studs on 16" (406 mm) centers is sheathed on the exterior with 1/2" (13mm) gypsum board using 2" (51 mm) drywall screws on 8" (203 mm) centers. A second exterior layer of 5/8" (1 6 mm) CDX plywood sheathing is applied using 8d coated "sinker" nails on 8' (203 mm) centers. The vinyl siding is then attached using 1 3/4 (44mm) aluminum ring nails every 16" (406 mm) on the vinyl nailing strip. 6. SUBSTANTIATING DATA 6.1 Manufacture's discriptive literature and installation instructions. 6.2 Associated Materials Inc.'s drawings on horizontal vinyl siding. 6.3 Wind loading tests, prepared by National Certified Testing Laboratories, Report Nos. NCTL- 210 - 1615 -4, NCTL- 210 - 1615 -5, & NCTL- 210 - 1615 -6, dated November 10, 1994, signed by Michael E. Lane. 6.4 Test report on physical properties fo vinyl siding, prepared by Architectural Testing Inc., Report No. ATI- 11421, dated September 17, 1993, signed by Jon Hill and David G. Moyer. 6.5 Test reports on wind loading tests of vinyl siding in accordance with ASTM D 5209 -91, prepared by Architectural Testing Inc. Report No. Date 01- 32591.04 November 1, 1998 http: // intranet. alside. com /tssg/ ArchitecturalSpecs /reports/sbcci.htm 3/23/2006 . Alside Home Siding - Product Specification and Profiler Page 3 of 5 01- 33614.01 01- 33614.03 01- 34403.02 01- 34404.01 01- 34579.03 signed by Jay Leader and Allen N. 7. CODE REFERENCES Standard Building Code -1999 Edition Section 103.7 Alternate Materials and Methods Section 708.2 Section 1403.1 Section 1403.9 Section 2308.2 International One and Two Family Dwelling Code -1998 Edition Section 108 Alternate Materials and Systems Section 703 Exterior Covering 8. COMMITTEE FINDINGS January 4, 1999 January 4, 1999 June 6, 1999 June 1, 1999 June 1, 1999 Reeves, P.E. Concealed Installation General - Veneered Walls Rigid Vinyl Bracing of Exterior Stud Walls The Committee on Evaluation in review of the data submitted finds that, in their opinion, the Alside Premium Vinyl Siding as described in this report conforms with or is a suitable alternate to that specified in the Standard Building Code and the International One and Two Family Dwelling Code or Supplements thereto. 9. LIMITATIONS 9.1 This Evaluation Report and the installation instructions, when required by the building official, shall be submitted at the time of permit application. 9.2 Siding shall be used on Type VI construction only. 9.3 Siding shall be installed only on exterior walls covered by a solid sheathing (structural or non - structural) 9.4 All siding and accessories must be fastened to studs or other solid nailing surfaces or nail -base sheathing must be used. 9.5 Alside Premium Vinyl Siding shall be installed by an Alside Division of Associated Materials' authorized contractor. 10. IDENTIFICATION All Alside Premium Vinyl Siding Panels and Accessories covered by this report shall bear the manufacturer's name and /or trademark, the model number, the SBCCI Public Safety Testing and Evaluation Services, Inc. initials (SBCCI PST & ESI) or seal, and the number of this report for field identification. This identification may appear on the panel or on the shipping cartons. http: / /intranet. alside. com /tssg/ ArchitecturalSpecs /reports/sbcci.htm 3/23/2006 &lside Home Siding - Product Specification and Profiler Page 4 of 5 Table I THE FOLLOWIHG MATERIALS ARE DISTRIBUTED AS ALSIDE AND GUARD - ALL VINAL SIDINGS PRODUCT PRODUCT DESCRIPTION NAME Charter Oak Horizontal Double 4 1/2" Charter Oak Conquest Conquest Conquest Double 4" Double 5" Dutch Lap 4" Dutch Lap 5" Double 4 1/2" Dutch Lap 4 1/2" Sears Greenbriar III Williamsport Colonial Clapboard Siding Horizontal Double 4 1/2" Dutch Lap Siding Horizontal Double 4 1/2" Clapboard Siding Horizontal Double 4 1/2" Dutch Lap Siding Horizontal Triple 3" Siding 9" ODYSSEY PLUS SERIES Horizontal Double 4 "' 6 „ Clapboard Siding Horizontal Double 5 "' Clapboard Siding Horizontal Double 4" Dutch Lap Siding Horizontal Double 5" Dutch Lap Siding CENTER LOCK SERIES Horizontal Double 4 1/2" Clapboard Siding Horizontal Double 4 1/2" Dutch Lap Siding Horizontal Double 4 1/2" Clapboard Siding HISTORICAL COLLECTION Horizontal Triple 3" Clapboard Siding Horizontal 6 %" Beaded Clapboard Siding ALPHA SERIES Double 4" Horizontal Double 4" 8" Clapboard Siding Dutch Lap 4" Horizontal Double 4" Dutch 6 „ Lap Siding SOFFITS EXPOSURE 9 " 9 " 9 " 9 " 1 0" 8" 10" 9 " 9 " 9" 9 " 6 1/2" PRODUCT THICKNESS .046" PRODUCT LENGTH 12' -1" .046" 12' -1" .040" 12' -1" .040" 12' -1" .040" 12' -1" .044" 12'-6" .044" 12' -0" .044" 12' -O" .044" 12' -O" .042" 12 -1" .042" 12 -1" .044" 12 -1" .044" 12' -1" .044" 12'-4" .040" 12-6" .040" 12-6" http: / /intranet. alside .com /tssg/ArchitecturalSpecs /reports /sbcci.htm 3/23/2006 - • • -.Asside Home Siding - Product Specification and Profiler Super Span Heavy Gauge Premium Vinyl Soffit Series E and 2T Premium Vinyl Grained Soffit -12" Charter Oak Soffit Greenbriar Beaded Soffit V- Grooved Super Span Soffit, Aerated or Non - Aerated 11. PERIOD OF ISSUANCE V- Grooved Premium Soffit, Aerated or Non - Aerated V- Grooved Reinforced Lock Soffit, Aerated or Non - Aerated V- Grooved Beaded Soffit, Aerated or Non - Aerated SEE CURRENT SBCCI PST 8 ESI EVALUATION REPORT LISTING FOR STATUS OF THIS EVALUATION REPORT. 10" .044" 12' -0" 12" .040" 12'-6" 10" .042" 12' -0" 8" .044" 12'-6" For information on this report contact: Woods McRoy, P. E. 205/599 -9800 REPORT NO. 9632C Page 5 of 5 http: / /intranet. alside. com /tssg/ ArchitecturalSpecs /reports/sbcci.htm 3/23/2006 May US U6 05:46p FAX MESSAGE SUBJECT: MESSAGE: Ken, CHASE EQUIPMENT CO. 118 WEST STREETSBORO ROAD #213 HUDSON OH 44236 TEL. 330450 -3681 FAX. 330- 342 -9501 DATE: Tuesday, May 09, 2006 NO. OF PAGES: 3 ATTN: Mr. Ken Nelson, Senior Plan Examiner Tukwila Building Division Permit Application D06 -132 Pursuant to your Review Memo dated April 24, 2006 concerning the Ramset Trubott Anchor Bolts, please see the accompanying pa is- of the ICC Evaluation Report No. ER -137F2 for the spE c anchoo and copy of the ICC NOTE "Al! of the evaluation reports that?nay be ► downloaded from this web site are valid, although some have re -examination dates that have passed. In the case of the latter, the reports are currently undergoing re- examination as required by ICC -ES Rules of Procedure ". So, apparently the original evaluation under the UBC is still considered valid until re- examination and new ICC rules to take effect in 2007. We hope that this information is satisfactory and meets with your approval. Sincerely, Chase Equipment Terry L. Yonker Chase Equipment Co. cc: Mr. Ryan George - AMI- Alside p. 2 RECEIVED MAY 10 2006 PERMIT CENTER CORRECTION LTR# ANCHOR DIAMETER RaarA11A11011 TORQUE Mstaeolaterr d'.n2ace pal re n4aaapd t o *A.000Doe Aelun Meer Teslw Mw Ts.bn Steer 'Stn imESes teamed bsp.earh lam, YR n aRped Was � Without iraphrhe a s p.dr.m 11 4': 4 8 Embus/ 1 t h 295 150 350 445 225 350 475 240 350 "62 2 1 525 265 420 825 410 420 825 410 420 24 565 280 R25 410 825 410 3 /E 25 0@ 420 210 580 560 280 655 710 355 790 3 870 435 1,030 1,485 740 1,035 1,530 765 1,125 4 3.200 600 1,485 740 1,530 765 112 55 1.760 41/4 1.165 580 1,810 2.410 1.205 1,810 2,705 1.355 2,040 6 1.335 665 2,410 1.205 2,705 1.355 1/4 . 90 15 /4 1.645 820 1,780 1.795 900 1,780 2.430 1,215 2.405 51/4 1,645 820 2,400 3.730 1.865 2,975 4,095 2,045 3.130 7 1,765 880 3.755 1,880 4.095 2,045 3 /43 175 3 1,780 890 2,530 2,710 1,355 3,430 3.325 1,665 3,995 6 2,745 1.375 5,080 4,425 2210 5.935 5.065 2.530 5,935 10 2,745 1,375 4.470 2.235 5,895 2.950 7 6, 250 3 2380 1,1913 3,290 3.685 1,840 4,145 4,355 2.180 4,790 6 14 3,665 1,835 5220 5.235 2,620 7.200 6.090 3.045 7200 3.665 1,e3S 3580 2,790 6,090 3.045 1 300 41/2 3,485 1,745 4.020 5,045 2,520 5.705 5,295 2,650 6.120 7 3,650 1,825 7.170 5,995 3,000 9.485 8,315 4,160 9.520 9 4.675 2,340 6,635 3,315 8,315 4,160 1 500 5 4,535 2.270 5.820 6.595 3.303 7.365 8.410 4,205 8,445 8 6,835 3.413 8,770 10,825 5.410 11,065 11385 5,695 12,640 I0 9,035 4,515 11.385 5.695 14.075 7,040 EOLT I11ASIETER (MEM ANCHOR OM ere,.,,, °i ma ya Sena) DESCRIERS:* &SP Ohsncv Iteeconat e• OIlS. MIn Ma. Wester' bbd Pass/ Mlaewable Rowan �Ma wanah9 Lad Socha) la Allowelake Species &t ire t.o.at w a *SS bAmbn •aro fa Sheer UM. UM. 'aS,- ` � p o a OAS lrTesb, t75 ter SS" ',1/4 /m 10/32 1/ 3 3 115 /16 i 3 /e 9/16 11/ 2 13/s 5 2 : I /2 11/16 2 3 1 7 3 /b "62 2 4 2 Oho 43/5 �3I 51 /I6 31 4 1 3l/ 5 23/4 17 May 09 06 05:48p Page 3 of 7 Chase Equipment TABLE 2—RECOMMENDED SPACING AND EDGE DISTANCE REQUIREMENTS FOR I1W RAMSET )RED HEAD SELF - DRILLING ANCHOR' ForS1: I inch 25.4 ILincr iivapoletion may be used for intermediate spacing and edge distances, TABLE 3-41W RAMSETIRED HEAD TRUBOLT WEDGE ANCHOR ALLOWABLE SHEAR AND TENSION VALUES (pountffi) p.3 ER -7372 For SI: 1 inch a 25.4 nun, I p6 - 6.891tPa, I Ibf • ft » 1355 SLR N • m, 1 Ibf•' 4.45 N. 1 Tlte tabulated shearadtensil vahasare foram-hors hNmiledin taoaraggregam concrete-having the designated ultimate compressive strength at the time ofInnen :lion 2 The holes are tilled with bits complying with ANSI 821215-I994. The bit diameter equals the anther diameter. 'Them tension values are o phcnblc only ,then the anchor we Stalled with spacial inspection as sad font, in Section 2.5. hbc minimum concrete titian is 1 times One embedment depth, or the embedment depth plus three time the anchor diameter, whichever is greater. SAllowa,le atstic loads may be Mused etc -third for earthquake or wind (SAW= in accordance with Section 161233 of the code. No further increase is allowed. 6 77re anthers are i/heNamd a &glows: IIum ICC -ES: Evaluation Reports Page I of 2 Ust Reports Search Reports CSI List Appiicalian, tnfo iai Guidelines f,'•... Lahslfdsptsifc ;s Comm{tt ufactu crAudits Evaluation Reports http:// www. icc- es. otg /Evaluation_Reports/index.shtml Download and Install the tree Adobe Acrobat Reader. 4LI Read er ; about us I FAQs I site map I contact I help • Complete list of evaluation reports • Search for a specific report • Reports arranged by CS1 (Construction Specifications Institute) category • Most recent reports /expirations • Legacy reports converted to new ICC -ES evaluation reports • Evaluation Report Index PLEASE NOTE: All of the evaluation reports that may be downloaded from this web site are valid, although some have re- examination dates that have passed. In the case of the latter, the reports are currently undergoing re- examination as required by ICC -ES Rules of Procedure. Home I Evaluation Reports I Application Info I Criteria /Guidelines I labs /Inspections Committee Meetings i QC Manuals I Manufacturer Audits Our parent company, the International Code Council Contact Us Ci 2006 ICC Evaluation Service, Inc. 5/9/2006 eusiue name owing - rrvuuei opecufcauvu anti rainier rage . v. v PRINTED JANUARY, 1995 Editorial Revision: January, 1997 B 0 C A RESEARCH REPORT NO. 93 -42 BOCA EVALUATION SERVICES, INC. ASSOCIATED MATERIALS, INC. P.O. BOX 2010 AKRON, OH 44309 1.0 DESCRIPTION OF EVALUATION 2.0 DESCRIPTION AND USE OF PRODUCT 2.1 GENERAL DESCRIPTION 2.2 INSTALLATION http: / /intranet. alside. com/ tssg/ ArchitecturalSpecs /reports/jan1995.htm A Participating Member of the NES, Inc. FILE COPY DIVISION 07 - THERMAL AND MOISTURE PROTECTION SECTION 07460 - SIDING ALSIDE AND GUARD -ALL VINYL SIDINGS I �REVIEWED d000ni MAY 12 2006 Clt Of Tukwila IT IP nr » ^ " lam I This report evaluates the use of Alside and Guard -All horizontal and vertical sidings and horizontal soffits as exterior weather - resistant coverings on all types of construction through a review of the manufacturer's literature; installation instructions; and physical, weathering and radiant heat exposure testing results. Alside and Guard -All horizontal and vertical lap vinyl sidings are manufactured from solid, rigid polyvinyl chloride (PVC) compound. complying with the requirements of ASTM D3679 -91a, for use as an exterior weather covering. The minimum thickness of all siding and soffit styles shall be 0.035 inch (0.9 mm). Alside and Guard -All vinyl sidings are available in a variety of colors and wood -grain textures with matching inside and outside corner posts, trim and moldings. A horizontal soffit in a matching color is also available. Soffit material is available in a vented design. Refer to Table I at the end of this report for siding/soffit characteristics and profiles for each siding/soffit style. Par L32 3/23/2006 'sslor s. 2rize 'Pt RECEIVED CITY OF TUKWILA ANrl 13 2006 r'ERMIT CENTER ntstue nuuie oiuui% - oyci:uivuuvii ravu.ci The installation of the Alside and Guard -All vinyl sidings shall be in accordance with the Vinyl Siding Institute's Rigid Vinyl Siding Applications Instructions by a contractor authorized by Associated Materials, Inc., and shall be subject to the limitations stated in this report. When attaching vinyl siding to concrete, masonry, or other nonnailable substrates, wood furring strips, nominal size of 1 inch by 3 inches (25 mm by 75 mm), are attached to the substrate at 16 inches (400 mm) on center. Wood furring strips shall be fastened to the substrate with fasteners of sufficient size and spacing to withstand the design wind load. The type of wood furring strips used and the type, size, and spacing of the furring strip fasteners shall be selected to ensure proper anchorage of the furring to the substrate to for allow proper fastening of the siding. 3.0 CODE ANALYSIS OF SUBMITTED INFORMATION The following data were submitted by the proponent for demonstration of compliance with the respective code sections listed above each item of information. The basis is the BOCA National Building Code /1993. 3.1 WEATHER PROTECTION Code Section 1403.3 Weather resistance: This code section requires that exterior wall coverings be weather resistant and properly attached to resist wind and rain. INFORMATION SUBMITTED: Test report data from Architectural Testing, Inc., Report NumberAT1- 11421, dated September 17, 1993, indicate that Alside and Guard -All vinyl sidings have been tested to determine that resistance to weather, fading, and impact is in accordance with the requirements of ASTM D3679 -91a. 3.2 MATERIALS Code Section 1405.3 Materials: This code section states in Table 1405.3 that the minimum thickness of rigid PVC siding shall be 0.035 inch (0.9 mm). Code Section 14053.3 Rigid PVC siding: This code section states that rigid PVC siding shall conform to the requirements of ASTM D3679- 91a. J. 0461 L VS V http: / /intranet. alside. com /tssg/ ArchitecturalSpecs /reports/jan1995.htm 3/23/2006 rusrue mane awing - rruuucr apccun uuuu guru rruurcr INFORMATION SUBMITTED: Test report data from Architectural Testing, Inc., Report Number ATI- 11421, dated September 17, 1993, indicate that Alside and Guard -All vinyl sidings have a minimum thickness of 0.040 inch (1 mm) and are manufactured with materials that conform to the requirements of ASTM D3679 -91a. WIND LOAD Code Section 1611.8 Building components and cladding: This code section states that the building components and cladding shall be designed for external pressures caused by the basic wind speed. INFORMATION SUBMITTED: Test reports from National Certified Testing Laboratories, Report Numbers NCTL -2 10- 1615 -4, NCTL -2 10- 1615 -5, and NCTL- 210 -1615- 6, dated November 10, 1994, indicated that the maximum allowable wind design pressure shall not exceed 46.9 pounds per square foot (229 kilograms per square meter). Testing was performed that was equivalent to the requirements of ASTM D3679-91a. 3.4 RADIANT HEAT TEST Code Section 1406.2.1 Radiant heat exposure: This code section states that combustible exterior wall finish on buildings other than Type 5 construction shall be tested for exposure to radiant heat. Alside and Guard -All vinyl sidings were tested for radiant heat exposure in accordance with Section 1406.2.1 of the BOCA National Building Code /1993. INFORMATION SUBMITTED: Test results of radiant heat tests performed by Southwest Research Institute, Report Number 01- 4890 -030, dated November 8, 1993, show that the Alside and Guard -All vinyl sidings conform to the requirements for an unrestricted installation in accordance with Section 1406.2.1.3.1. 4.0 INSTRUCTIONS TO THE CODE OFFICIAL Alside and Guard -All vinyl sidings have been evaluated for compliance with the 1993 editions of the BOCA National Codes. This report is limited to the application and products as stated herein. This evaluation is based solely upon information provided to BOCA Evaluation Services, Inc., by Associated Materials, Inc. and has not been independently verified. BOCA -ES intends that the report be used by the . as., http: / /intranet. alside. com /tssg/ ArchitecturalSpecs /reports/janl995.htm 3/23/2006 Aisiae home swung - rroauct specincauon ana rromer code official to determine that Alside and Guard -All vinyl siding complies with those code requirements specifically addressed in Section 3.0 of this report, provided that this product is installed in accordance with the following limitations: Limitations 4.1 This report is subject to annual certification. Reports that are not certified shall not be used or referred to. In order to determine the status of certification of this report, contact BOCA Evaluation Services, Inc., or visit our web site at www.boca- es.com/ --boca -es to view the monthly listing of current reports. 4.2 Alside and Guard -All horizontal and vertical sidings and horizontal soffits shall be installed in accordance with this report and the manufacturer's installation instructions. 4.3 Evaluation of the wall assembly on which Alside and Guard -All vinyl sidings are applied is outside the scope of this report. Exterior wood frame walls shall have wind bracing which conforms to Section 2305.7 of the BOCA National Building Code /1993. 4.4 Buildings on which the siding and accessories are installed shall be adequately braced in accordance with the BOCA National Building Code /1993. 4.5 Vinyl sidings shall not be installed over combustible backing surfaces, except on buildings of Type 5 construction. Backing surfaces for the vinyl siding shall conform to Section 1405.2.1 for rigidity, stability, and weather resistance. Buildings of Types 1, 2, 3, and 4 construction which require wood furring strips for the attachment of the siding shall have the furring strips installed in accordance with the manufacturer's instructions as required to provide fastening of the vinyl siding at a maximum spacing of 16 inches on center (400 mm). Wood furring strips, nominal size of 1 inch by 3 inches (25 mm by 75 mm), shall be attached to the substrate at a maximum of 16 inches (400 mm) on center and shall be fastened to the substrate with fasteners of sufficient size and spacing to withstand the design wind load. The type of wood furring strip used and the type, size, and spacing of the furring strip fasteners shall be specified and selected to ensure proper anchorage of the furring to the substrate to allow for proper fastening of the siding. 4.6 The areas where furring strips are used shall be firestopped in accordance with Section 720.6.1. 4.7 Alside and Guard -All horizontal and vertical sidings and horizontal soffits shall be limited to 40 feet (12.19 meters) in height above grade when installed on buildings of Type 1, 2, 3, or 4 construction. 4.8 Alside and Guard -All vinyl sidings shall be limited to 10 percent of the total exterior wall surface when the fire separation distance is less ragc'1 vi u http: / /intranet. alside. com/ tssfi/ ArchitecturalSpecs /reports/jan1995.htm 3/23/2006 Aistae Home swung - rroauct specmcauon ana rronter rage a of o than 5 feet (1.524 meters). 4.9 Alside and Guard -All vinyl sidings shall be Limited to installation in applications where the negative design wind pressure does not exceed 46.9 pounds per square foot (229 kilograms per square meter). 4.10 Face nailing of the vinyl siding panels is prohibited. Nailing of the siding shall be through either prepunched or field punched nail slots. 4.11 "Cut edges" of vinyl siding that result from the necessary cutting to fit around an opening in a wall such as a door or window, or into a gable end of the building shall be field punched to provide snap locks, and shall be slid into the appropriate receiving trim piece which has been previously nailed into position. 4.12 The use of foam plastic insulation boards behind the vinyl siding is outside the scope of this report. The use of the foam plastic insulation boards will require the submittal of additional information to the code official. 4.13 Thermal expansion provisions shall be provided by the installer of the vinyl siding. 5.0 INFORMATION REQUIRED ON CONSTRUCTION DOCUMENTS To aid in the use of this report, the following represents the minimum level of information to be reflected on construction documents in order to determine compliance with this research report. 5.1 The language "See BOCA Evaluation Services, Inc., Research Report No. 93 -42." 5.2 The building construction type. 53 The fire separation distance between the building and the lot line. 5.4 The height above grade for the vinyl siding installed on the building. 5.5 The wind design pressure values - positive and negative -used in the design of this building. 5.6 The area of total exterior wall and area of vinyl siding for a fire separation distance of 5 feet (1.524 meters) or less. 5.7 The product manufacturer's name, product model name and code, and the thickness of the vinyl siding and soffit to be used on the building. http: / /intranet. alside. com/ tssg/ ArchitecturalSuecs /renorts/ian1995.htm 3/23/2006 nisiae nome arung - rrouuet apecnicauun Lulu runner 5.8 The description of substrate materials and attachment method to the building. 5.9 The manufacturer shall provide the user of this report with complete instructions on the proper installation of Alside and Guard -All horizontal and vertical sidings and horizontal soffits. These instructions shall be available on the jobsite during the entire installation. 6.0 IDENTIFICATION All Alside and Guard -All horizontal and vertical sidings and horizontal soffits manufactured in accordance with this research report shall be marked at the plant with the identifying language, "See BOCA Evaluation Services, Inc., Research Report No. 93 -42." Reference to this research report is limited to the identification as described herein. In addition to the identification referencing the BOCA Evaluation Services, Inc., Research Report, Alside and Guard -All horizontal and vertical sidings and horizontal soffits described in Section 2.0 of this report shall bear the manufacturers name and/or trademark, the manufacturer's address, the compound class number of the vinyl used in the siding, a statement that the siding is in compliance with ASTM D3679 -91a, and the name of the testing agency. This identification shall be on the back of each siding piece or on each shipping carton. • First On America's Homes 1 agc V u1 1! http: / /intranet. alside. com/ tssg/ ArchitecturalSpecs /reports/ianl995.htm 3/23/2006 _ _ . _.-•• . ..., GENERAL SPECIFICATIONS FILE COPY Permit NO. ALSIDE PREMIUM VINYL SIDING CONFORMS TO ALL OF THE gr(717IREMENTS- ESTABLISHED IN THE MOST RECENT VERSION OF ASTM•SPBGIEWth'DQN D3679,, _._ DEVELOPED COOPERATIVELY WITH THEINDUSTRY AND PUBLISHED BY THE . ,.� AMERICAN SOCIETY FOR TESTING AND IJ�ATERIALS. . • c..:. . ALSIDE MAINTAINS RIGOROUS PRODUCTION QUALITY CONTROL STANDARDS TO ASSURE THAT PREMIUM VINYL SIDING WILL PERFORM AS INTENDED USE. L_ MATERIALS PROPERTIES ONSideSe First On America's Homes ARCHITECTURAL SPECIFICATIONS ALSIDE PREMIUM VINYL SIDING ODYSSEY PLUS DOUBLE 5" CLAPBOARD Page 1 of 3 ALSIDE PREMIUM VINYL SIDING IS PRODUCED FROM POLY(VINYL CHLORIDE)(PVC) COMPOUNDS MEETING THE REQUIREMENTS OF ASTM D 3679 FOR COMPOUND CLASS NUMBER 2 MATERIALS. TYPICAL COMPOUND PROPERTIES IMPACT STRENGTH @ 74° F IMPACT STRENGTH @ 32° F TENSILE STRENGTH MODULUS OF ELASTICITY IN TENSION DEFLECTION TEMPERATURE UNDER LOAD TYPICAL SIDING PROPERTIES LENGTH WIDTH THICKNESS WARP 3.86 ft.lbf/in of notch (ASTM D256) 2.4 ft.lbf/in of notch ( 5718 psi. (ASTM D6 399,800 psi. (ASTM 12 ft.± 1/8 in. 10 in. ± 1/8 in. 0.044 in. nominal 0.0 in. (ASTM D3679) http: / /intranet.al side. com/ tssg/ SidingSpecifications /OdSPlus.html 8) CODE COMPLIANCE 638) InnonU!D 186.8 °.F (ASTM D64 :) MAY 12 2006 ILIA e_ City Of Tukwila a� ITt_nTNC nWT Inn+ CITY RECEIVED TUKWIL4 APR 13 2006 PERMIT CENTER t7OI32- 3/23/2006 . ...a ,..vuv.• ., a.aayWatu HEAT SHRINKAGE IMPACT RESISTANCE WEATHERABILITY COEFFICIENT OF LINEAR EXPANSION GLOSS (75° GLOSSMETER) SURFACE DISTORTION EIRE RESISTANCE PROPERTIES AVERAGE TIME OF BURNING AVERAGE EXTENT OF BURNING FLAME SPREAD SMOKE DENSITY IGNITION PROPERTIES C O D E I, ALSIDE PREMIUM VINYL SIDING IS LISTED BY THE FOLLOWING CODE WRITING ORGANIZATIONS UNIFORM BUILDING CODE - ICBO EVALUATION SERVICES STANDARD BUILDING CODE - SBCCI PST & ESI NATIONAL BUILDING CODE - BOCA EVALUATION SERVICES FEDERAL HOUSING AUTHORITY - MEETS REQUIREMENTS OTHER TESTING: UNDERWRITER'S LABORATORIES ® - FILE R14214 http: / /intranet. alside. com/ ssg/ SidingSpecifications /OdSPlus.html 1.34% (ASTM D3679) 101 in -lb (ASTM D4226, PROC.A.H.25) NO SURFACE OR STRUCTURAL DEFECTS SUCH AS PEELING, CRACKING, CHIPPING, ETC. WHEN TESTED AS PRESCRIBED IN ASTM D3679. 3.53 X 10 - 5 in. /in. ° F (ASTM D696) 30° (ASTM D 3679) NO DISTORTION AT 120° F (ASTM D 3679) Page 2 of 3 <5 sec. (ASTM D635) <5 mm. (ASTM D635) 15 (ASTM E84) >500 (ASTM E84) SELF IGNITION DID NOT OCCUR. AT 680° F, SAMPLE BEGAN TO SMOLDER AND CONTINUED UNTIL CONSUMED. (ASTM D1929) 3123/2006 i �14F/WalLL ODYSSEY PLUS DOUBLE 5" CLAPBOARD A. INTERLOCKED PANEL WIDTH 10.0001.030 8. BOTTOM PANEL 6.0001.030 C. CENTER BUTT HEIGHT .84311120 D. BOTTOM BUTT HEIGHT 5981.020 E. BUTT HOOK LENGTH 288 +.030 •.000 F. PROFILE PANEL RADIUS 2028' G. NAIL STRIP EDGE TO LOCK 51111130 HALAL SLOTS CENTER .2501.020 J. NAIL BLOT HOLES .156 X 1.010 K. END NOTCHING 2.000'1.125 L LOCK HEIGHT .5101.020 WALL THICKNESS EXPOSED - .044 ±1002 WALL THICKNESS HANGER - .044(WO WEIGHT PER FOOT -283 LBS. OVERALL LENGTH —mot lir WEEP HOLE - .125 GIA.± .010 WARP - .12GIPANEL NANCENSER -1r A SCII& n A•5erito s Homes Page 3 of 3 http: / /intranet. alside. com /tssg/ SidingSpecifications /Od5Plus.html 3/23/2006 GENERAL SPECIFICATIO S First On America's Homes ARCHITECTURAL SPECIFICATIONS ALSIDE PREMIUM VINYL SIDING CONQUEST DOUBLE 4 %" CLAPBOARD ALSIDE PREMIUM VINYL SIDING CONFORMS TO ALL OF THE REQUIREMENTS ESTABLISHED IN THE MOST RECENT VERSION OF ASTM SPECIFICATION D3679, DEVELOPED COOPERATIVELY WITH THE INDUSTRY AND PUBLISHED BY THE AMERICAN SOCIETY FOR TESTING AND MATERIALS. ALSIDE MAINTAINS RIGOROUS PRODUCTION QUALITY CONTROL STANDARDS TO ASSURE THAT PREMIUM VINYL SIDING WILL PERFORM AS EXPECTED FOR ITS INTENDED USE. MATERIALS PROPERTIES Page 1 of 3 ALSIDE PREMIUM VINYL SIDING IS PRODUCED FROM POLY(VINYL CHLORIDE)(PVC) COMPOUNDS MEETING THE REQUIREMENTS OF ASTM D 3679 FOR COMPOUND CLASS NUMBER 2 MATERIALS. TYPICAL, COMPOTINT) PROPERTIES IMPACT STRENGTH @ 74° F IMPACT STRENGTH @ 32° F TENSILE STRENGTH MODULUS OF ELASTICITY IN TENSION DEFLECTION TEMPERATURE UNDER LOAD TYPICAL SIDING PROPERTIES LENGTH WIDTH THICKNESS WARP 3.86 ft.lbf/in of notch (ASTM D256) 2.4 ft.lbf/in of notch (ASTM D256) 5718 psi. (ASTM D638) 399,800 psi. (ASTM D638) 186.8° F (ASTM D648) 12 ft. 1 in. ± 1/8 in. 9 in. ± .030 in. 0.040 in. nominal 0.0 in. (ASTM D3679) http: / /intranet. alside. com/ tssg/ SidingSpecifications/CongD4.html 3/71 / 90 1) 4 vwlYuvJ� LV41-lV T iiL lapin) ant HEAT SHRINKAGE IMPACT RESISTANCE WEATHERABILITY COEFFICIENT OF LINEAR EXPANSION GLOSS (75° GLOSSMETER) SURFACE DISTORTION FIRE RESISTANCE PROPERTIES AVERAGE TIME OF BURNING AVERAGE EXTENT OF BURNING FLAME SPREAD SMOKE DENSITY IGNITION PROPERTIES CODE 1 JSTINGS 25 °/35° (ASTM D 3679) NO DISTORTION AT 120° F (ASTM D 3679) ALSIDE PREMIUM VINYL SIDING IS LISTED BY THE FOLLOWING CODE WRITING ORGANIZATIONS UNIFORM BUILDING CODE - ICBO EVALUATION SERVICES STANDARD BUILDING CODE - SBCCI PST & ESI NATIONAL BUILDING CODE - BOCA EVALUATION SERVICES FEDERAL HOUSING AUTHORITY - MEETS REQUIREMENTS OTHER TESTING: UNDERWRITER'S LABORATORIES ® - FILE R14214 Page 2 of 3 0.93% (ASTM D3679) 101 in -lb (ASTM D4226, PROC.A.H.25) NO SURFACE OR STRUCTURAL DEFECTS SUCH AS PEELING, CRACKING, CHIPPING, ETC. WHEN WHEN TESTED AS PRESCRIBED IN ASTM D3679. 3.53 X 10 - 5 in. /in. ° F (ASTM D696) <5 sec. (ASTM D635) <5 mm (ASTM D635) 15 (ASTM E84) >500 (ASTM E84) SELF IGNITION DID NOT OCCUR. AT 680° F, SAMPLE BEGAN TO SMOLDER AND CONTINUED UNTIL CONSUMED. (ASTM D 1929) http: / /intranet. alside. com/ tssg/ SidingSpecifications/CongD4.html 3/23/2006 '.+V11quCaL LVLLULV Y 1/L 1i1411UUWV CONQUEST DOUBLE 4-112" CLAPBOARD L1 k E A. INTERLOCKED PANEL WIDTH 9.O00f.030 N. BOTTOM PANEL 4.600.021 C. CENTER BUT HEIGHT .653*020 D. BOTTOM MITT HEIGHT .511&310 E. BUTT ROOK LENGTH .440 +.030 •.000 F. P1IORLE PANEL RAOIOS 308111 L OAO. STRIP TOE TO LOCKk625 .030 11. NAIL SLOTS CENTER 250 ±.082 .1. NAIL SLOT HOLES .1SO X f.010 K. END VOICING LOW ±..125 1. LOCK INERT 97#.060 WALL7111MM EXPOSED -JSI0 WALL1111CCN SS BANDER -fl PINO WEIGHT FIR FOOL - 1115 L88. OVERALL LEWD - 12'$•t tD' VEEP IOU - .1250IAtJ11D WARP - .1237MIEL NILLCENTER - 15 - JKAKSDTS I � ENLARDEO VIEW K I>ot a Ama4cis Hames rage .5 or s http: / /intranet. alside. com/ tssg/ SidingSpecifications /CongD4.html 3/23/2006 1L11Mt1VY 1T ? L&J 1 UV1111. GENERAL SPECIFICATIONS MATERIA! S PROPERTIES TYPICAL, COMPOUND PROPERTIES IMPACT STRENGTH @ 74° F IMPACT STRENGTH @ 32° F TENSILE STRENGTH MODULUS OF ELASTICITY IN TENSION DEFLECTION TEMPERATURE UNDER LOAD TYPICAL SIDING PROPERTIES LENGTH WIDTH THICKNESS WARP First On America's Homes a ARCHITECTURAL SPECIFICATIONS ALSIDE PREMIUM VINYL SIDING ALLIANCE T4 SOFFIT ALSIDE PREMIUM VINYL SOFFIT CONFORMS TO ALL OF THE REQUIREMENTS ESTABLISHED IN THE MOST RECENT VERSION OF ASTM SPECIFICATION D3679, DEVELOPED COOPERATIVELY WITH THE INDUSTRY AND PUBLISHED BY THE AMERICAN SOCIETY FOR TESTING AND MATERIALS. ALSIDE MAINTAINS RIGOROUS PRODUCTION QUALITY CONTROL STANDARDS TO ASSURE THAT PREMIUM VINYL SOFFIT WILL PERFORM AS EXPECTED FOR ITS INTENDED USE. ALSIDE PREMIUM VINYL SOFFIT IS PRODUCED FROM POLY(VINYL CHLORIDE)(PVC) COMPOUNDS MEETING THE REQUIREMENTS OF ASTM D 3679 FOR COMPOUND CLASS NUMBER 2 MATERIALS. 3.86 ft.lbf/in of notch (ASTM D256) 2.4 ft.lbf/in of notch (ASTM D256) 5718 psi. (ASTM D638) 399,800 psi. (ASTM D638) 186.8° F (ASTM D648) 12 ft.± 1/4 in. 12 in. ± 1/8 in. 0.040 in. nominal 0.0 in. (ASTM D3679) http: / /intranet.alside .com/tssg/SidingSpecifications /Alliance %20T4.HTML rage 1 or 4 3/23/2006 HEAT SHRINKAGE IMPACT RESISTANCE WEATHERABILITY COEFFICIENT OF LINEAR EXPANSION GLOSS (7? GLOSSMETER) SURFACE DISTORTION VENTILATION 7 SQUARE INCHES NET FREE OPEN AREA PER LINEAR FOOT. EIRE RESISTANCE PROPERTIES AVERAGE TIME OF BURNING AVERAGE EXTENT OF BURNING FLAME SPREAD SMOKE DENSITY IGNITION PROPERTIES C IDF I JSTINGS 0.93% (ASTM D3679) 101 in -lb (ASTM D4226, PROC.A.H.25) NO SURFACE OR STRUCTURAL DEFECTS SUCH AS PEELING, CRACKING, CHIPPING, ETC. WHEN TESTED AS PRESCRIBED IN ASTM D3679. 3.53 X 103 in. /in. ° F (ASTM D696) 35° (ASTM D 3679) NO DISTORTION AT 120° F(ASTM D 3679) <5 sec. (ASTM D635) <5 mm. (ASTM D635) 15 (ASTM E84) >500 (ASTM E84) SELF IGNITION DID NOT OCCUR. AT 680° F, SAMPLE BEGAN TO SMOLDER AND CONTINUED UNTIL CONSUMED (ASTM D 1929) ALSIDE PREMIUM VINYL SOFFIT IS LISTED BY THE FOLLOWING CODE WRITING ORGANIZATIONS UNIFORM BUILDING CODE - I030 EVALUATION SERVICES STANDARD BUILDING CODE - SBCCI PST & ESI NATIONAL BUILDING CODE - BOCA EVALUATION SERVICES FEDERAL HOUSING AUTHORITY - MEETS REQUIREMENTS OTHER TESTING: UNDERWRITER'S LABORATORIES ® - FILE R14214 rage z oI 4 http: / /intranet. alside .com /tssg/SidingSpecifications /Alliance %20T4.HTML 3/23/2006 • - - -- -- - • ...-j • ... - . ALLIANCE T4 12" SOFFIT A. INTERLOCKED PANEL WIDTH 12.000 ± 0.030 B. CEP1IER&TDP r'ANEL = 4.000 ± 0.030 I I . CENTER SUIT 1-EIGHT = 0.500 ± 1020 - D. BOTTOM BUTT HEIGHT = 0.450 t .020 E. BUTT HOOK LENGTH = 0.412 +0.033 -0.000 r. PROF:LE PANEL RADIUS = 31.486" C. NAIL STRIP EDGE TO LOCK 0.500 ± 0.060 IL NAIL SLOTS CENTER = 0.250 ± 0.062 :. LOCK HEIGHT = 0.350 t 0.030 J. NAI_ SLOT HOLES = 0.155 X 1.010 WALL THICKNESS EXPOSED -.040 + .002 -.001 WALL THICKNESS HANGER s.040 (MIN) WEKJHT PER FOOT =.385 LOS. OVERALL LENGTH r12' -C t 1/3" FLIP UNIFORM = .500 MAX. WARP - .125 NAIL CENTER - - = 16 Firs. On Amettes limes • http: / /intranet. alside .com /tssg/SidingSpecifications /Alliance %20T4.HTML rage a or 4 3/23/2006 GENERAL SPECIFICATIONS First On America's Homes ARCHITECTURAL SPECIFICATIONS ALSIDE PREMIUM VINYL SIDING ALLIANCE T4 CENTER VENT SOFFIT ALSIDE PREMIUM VINYL SOFFIT CONFORMS TO ALL OF THE REQUIREMENTS ESTABLISHED IN THE MOST RECENT VERSION OF ASTM SPECIFICATION D3679, DEVELOPED COOPERATIVELY WITH THE INDUSTRY AND PUBLISHED BY THE AMERICAN SOCIETY FOR TESTING AND MATERIALS. ALSIDE MAINTAINS RIGOROUS PRODUCTION QUALITY CONTROL STANDARDS TO ASSURE THAT PREMIUM VINYL SOFFIT WILL PERFORM AS EXPECTED FOR ITS INTENDED USE. MATERIALS PROPERTIES Page 1 of 4 ALSIDE PREMIUM VINYL SOFFIT I5 PRODUCED FROM POLY(VINYL CHLORIDE)(PVC) COMPOUNDS MEETING THE REQUIREMENTS OF ASTM D 3679 FOR COMPOUND CLASS NUMBER 2 MATERIALS. TYPICAL COMPOUND PROPERTIES IMPACT STRENGTH @ 74° F IMPACT STRENGTH @ 32° F TENSILE STRENGTH MODULUS OF ELASTICITY IN TENSION DEFLECTION TEMPERATURE UNDER LOAD TYPICAT, SIDING PROPERTIES LENGTH WIDTH THICKNESS WARP 3.86 ft.lbf/in of notch (ASTM D256) 2.4 ft.lbf/in of notch (ASTM D256) 5718 psi. (ASTM D638) 399,800 psi. (ASTM D638) 186.8° F (ASTM D648) 12 ft.± 1/4 in. 12 in. ±1 /8in. 0.040 in. nominal 0.0 in. (ASTM D3679) http: / /intranet.al side. com /tssg/ SidingSpecifications /AllianceT4CVENT.HTML 3/23/2006 HEAT SHRINKAGE IMPACT RESISTANCE WEATHERABILITY CODR LISTINGS COEFFICIENT OF LINEAR EXPANSION GLOSS (75° GLOSSMETER) SURFACE DISTORTION AVERAGE TIME OF BURNING AVERAGE EXTENT OF BURNING FLAME SPREAD SMOKE DENSITY IGNITION PROPERTIES OTHER TESTING: UNDERWRITER'S LABORATORIES ® - FILE R14214 0.93% (ASTM D3679) 101 in -lb (ASTM D4226, PROC.A.H.25) NO SURFACE OR STRUCTURAL DEFECTS SUCH AS PEELING, CRACKING, CHIPPING, ETC. WHEN TESTED AS PRESCRIBED IN ASTM D3679. 3.53 X 10 - 5 in. /in. ° F (ASTM D696) 35° (ASTM D 3679) NO DISTORTION AT 120° F(ASTM D 3679) VENTILATION 2.3 SQUARE INCHES NET FREE OPEN AREA PER LINEAR FOOT. FIBERESISTANCE PROPERTIES ALSIDE PREMIUM VINYL SOFFIT IS LISTED BY THE FOLLOWING CODE WRITING ORGANIZATIONS UNIFORM BUILDING CODE - ICBO EVALUATION SERVICES STANDARD BUILDING CODE - SBCCI PST & ESI NATIONAL BUILDING CODE - BOCA EVALUATION SERVICES FEDERAL HOUSING AUTHORITY - MEETS REQUIREMENTS http: / /intranet. alside. com/ tssg/ SidingSpecifications /AllianceT4CVENT.HTML rage L of 4 <5 sec. (ASTM D635) <5 mm. (ASTM D635) 15 (ASTM E84) >500 (ASTM E84) SELF IGNITION DID NOT OCCUR. AT 680° F, SAMPLE BEGAN TO SMOLDER AND CONTINUED UNTIL CONSUMED. (ASTM D1929) 3/23/2006 ALLIANCE T4 1 SOFFIT A. INTERLOCKED PANEL WIDTN 12.000 f 1).030 B. CEh1ER&TDP PANEL = 4,000 ± 0.030 C. CENTER BUTT ! SIGHT = 0.500 i 0.020 D. BOTTOM BUTT HEIGHT = 0.450 i .020 E. BUTT HOOK LENGTH = 0.412+0.030 -0.0X F. PROF:LE PANEL RADIUS = 31.466" C. NAIL STRP EDGE TO LOCK 0.500 ± M060 NAIL SLOTS CENTER = 0.250 ± 0.052 :. LOCK HEGHT = 0350 t 0.030 J. NAIL SLOT HOLES = 0.156 X 1.010 NAIL THICKNESS EXPOSED -.040 + .002 -.001 WALL THICKNESS HANGER -.040 411N) WEIGHT PER FOOT =385 LSS. OVERALL LEITH 612` -B" t 1/5" FLW UNIFORM = .500 MAX. WARP - .125 Mt. CENTER - - 16 d alliSidelliC rIrst On l4reco's Names http: / /intranet.al side. com/ tssg/ SidingSpecifications /AllianceT4CVENT.HTML rage .1014 3/23/2006 l.1 14.. 11c11 /Y111 ♦ 111'1 31)1111 ra c 1 U1 J GENERAT, SPECIFICATIONS F irst On America's Homes ARCHITECTURAL SPECIFICATIONS ALSIDE PREMIUM VINYL SIDING 2T PREMIUM 12" SOFFIT ALSIDE PREMIUM VINYL SOFFIT CONFORMS TO ALL OF THE REQUIREMENTS ESTABLISHED IN THE MOST RECENT VERSION OF ASTM SPECIFICATION D3679, DEVELOPED COOPERATIVELY WITH THE INDUSTRY AND PUBLISHED BY THE AMERICAN SOCIETY FOR TESTING AND MATERIALS. ALSIDE MAINTAINS RIGOROUS PRODUCTION QUALITY CONTROL STANDARDS TO ASSURE THAT PREMIUM VINYL SOFFIT WILL PERFORM AS EXPECTED FOR ITS INTENDED USE. MATERIALS PROPERTIES ALSIDE PREMIUM VINYL SOFFIT IS PRODUCED FROM POLY(VINYL CHLORIDE)(PVC) COMPOUNDS MEETING THE REQUIREMENTS OF ASTM D 3679 FOR COMPOUND CLASS NUMBER 2 MATERIALS. TYPICAL COMPOUND PROPERTWS IMPACT STRENGTH @ 74° F IMPACT STRENGTH @ 32° F TENSILE STRENGTH MODULUS OF ELASTICITY IN TENSION DEFLECTION TEMPERATURE UNDER LOAD TYPICAL SOFFIT PROPERTIES LENGTH WIDTH THICKNESS WARP 186.8° F (ASTM D648) 12 ft.+ 1/4 in. 12 in. ± 1/8 in. 0.040 in. nominal 0.0 in. (ASTM D3679) http: / /intranet. alside. com /tssg/ SidingSpecifications /2TSoffit.html 3.86 ft.lbf/in of notch (ASTM D256) 2.4 ft.lbf/in of notch (ASTM D256) 5718 psi. (ASTM D638) 399,800 psi. (ASTM D638) 3/23/2006 r. . r .. VYYW.I . 11131 LJVl111. HEAT SHRINKAGE IMPACT RESISTANCE WEATHERABILITY COEFFICIENT OF LINEAR EXPANSION GLOSS (75° GLOSSMETER) SURFACE DISTORTION AVERAGE TIME OF BURNING AVERAGE EXTENT OF BURNING FLAME SPREAD SMOKE DENSITY IGNITION PROPERTIES CODE LISTINGS OTHER TESTING: UNDERWRITER'S LABORATORIES ® - FILE R14214 0.93% (ASTM D3679) 101 in-lb (ASTM D4226, PROC.A.H.25) NO SURFACE OR STRUCTURAL DEFECTS SUCH AS PEELING, CRACKING, CHIPPING, ETC. WHEN TESTS AS PRESCRIBED IN ASTM D3679. 3.53 X 103 in. /in. ° F (ASTM D696) VENTILATION 7 SQUARE INCHES NET FREE OPEN AREA PER LINEAR FOOT. FIRE RESISTANCE PROPERTIES 35° (ASTM D 3679) NO DISTORTION AT 120° F(ASTM D 3679) rage 2 Ot 3 <5 sec. (ASTM D635) <5 mm. (ASTM D635) 15 (ASTM E84) >500 (ASTM E84) SELF IGNITION DID NOT OCCUR. AT 680° F, SAMPLE BEGAN TO SMOLDER AND CONTINUED UNTIL CONSUMED (ASTM D 1929) ALSIDE PREMIUM VINYL SIDING IS LISTED BY THE FOLLOWING CODE WRITING ORGANIZATIONS UNIFORM BUILDING CODE - ICBO EVALUATION SERVICES STANDARD BUILDING CODE - SBCCI PST & ESI NATIONAL BUILDING CODE - BOCA EVALUATION SERVICES FEDERAL HOUSING AUTHORITY - MEETS REQUIREMENTS http: / /intranet. alside. com/ tssg/ SidingSpecifications /2TSoffit.html 3/23/2006 - - - . ............... • .,...... [Return 7 T Soffit 12" A. INTERLOCKED PANEL WIDTH = 12.000 ±,030 B. CENTER &TOP PANEL = 4.000 +.030 C. CENTER BUTT HEIGHT= .500 ± .020 D. BOTTOM BUTT HEIGHT= .460 ± .020 E. BUTT HOCK LENGTH = .412 +.030 -.000 F. PROFILE PANEL RADIUS = 31.5" WALL THICKNESS EXPOSED =.440 +,002 -_pO1 WALL 71 HANGER —,o40 (lANN) WEIGHT PER FOQ1 — ,380 LBS, OVERALL LENGTH - i2'-6' ± 1 /e' http: / /intranet. alside. com/ tssg/ SidingSpecifications /2TSoffit.html rage 3 Or J 3/23/2006 LIILiILCI VMS. JU111L VICIuLCLL) rage 1 01 J ALSIDE PREMIUM VINYL SIDING CHARTER OAK REINFORCED LOCK PREMIUM VINYL SOFFIT (AERATED) GENERAL SPECIFICATIONS 1St® First On America's Homes ARCHITECTURAL SPECIFICATIONS ALSIDE PREMIUM VINYL SOFFIT CONFORMS TO ALL OF THE REQUIREMENTS ESTABLISHED IN THE MOST RECENT VERSION OF ASTM SPECIFICATION D4477, DEVELOPED COOPERATIVELY WITH THE INDUSTRY AND PUBLISHED BY THE AMERICAN SOCIETY FOR TESTING AND MATERIALS. ALSIDE MAINTAINS RIGOROUS PRODUCTION QUALITY CONTROL STANDARDS TO ASSURE THAT PREMIUM VINYL SOFFIT WILL PERFORM AS EXPECTED FOR ITS INTENDED USE. MATERIALS PROPERTIES ALSIDE PREMIUM VINYL SOFFIT IS PRODUCED FROM POLY(VINYL CHLORIDE)(PVC) COMPOUNDS MEETING THE REQUIREMENTS OF ASTM D 4477 FOR COMPOUND CLASS NUMBER 2 MATERIALS. TYPICAL COMPOUND PROPERTIES IMPACT STRENGTH @ 74° F IMPACT STRENGTH @ 32° F TENSILE STRENGTH MODULUS OF ELASTICITY IN TENSION DEFLECTION TEMPERATURE UNDER LOAD TYPICAL SOFFIT PROPERTIES LENGTH WIDTH THICKNESS WARP 3.86 ft.lbf/in of notch (ASTM D256) 2.4 ft.lbf/in of notch (ASTM D256) 5718 psi. (ASTM D638) 399,800 psi. (ASTM D638) 186.8° F (ASTM D648) 12ft.f %in. loin. ± 1/8 in. 0.042 in. nominal 0.0 in. (ASTM D3679) http: / /intranet. alside. com /tssg/ SidingSpecifications /COSFT.HTML 3/23/2006 t.,1lal LC1 % MR JUILIt �HefateuJ HEAT SHRINKAGE IMPACT RESISTANCE WEATHERABILITY COEFFICIENT OF LINEAR EXPANSION GLOSS (75° GLOSSMETER) VENTfI,ATION NET FREE OPEN AREA FIRE RESISTANCE PROPERTIES AVERAGE TIME OF BURNING AVERAGE EXTENT OF BURNING FLAME SPREAD SMOKE DENSITY IGNITION PROPERTIES CODE 1 JSTINGS 35° (ASTM D 3679) 3.2 SQUARE INCHES/FOOT ALSIDE PREMIUM VINYL SOFFIT IS LISTED BY THE FOLLOWING CODE WRITING ORGANIZATIONS UNIFORM BUILDING CODE - ICBO EVALUATION SERVICES STANDARD BUILDING CODE - SBCCI PST & ESI NATIONAL BUILDING CODE - BOCA EVALUATION SERVICES FEDERAL HOUSING AUTHORITY - MEETS REQUIREMENTS OTHER TESTING: UNDERWRITER'S LABORATORIES ® - FILE R14214 http: / /intranet.al side. com/ tssg/ SidingSpecifications/COSFT.HTML 0.93% (ASTM D3679) 101 in -lb (ASTM D4226, PROC.A.H.25) NO SURFACE OR STRUCTURAL DEFECTS SUCH AS PEELING, CRACKING, CHIPPING, ETC. WHEN TESTED AS PRESCRIBED IN ASTM D3679. 3.53 X 10 "5 in. /in. ° F (ASTM D696) rage L 01 <5 sec. (ASTM D635) <5 mm. (ASTM D635) 15 (ASTM E84) >500 (ASTM E84) SELF IGNITION DID NOT OCCUR. AT 680° F, SAMPLE BEGAN TO SMOLDER AND CONTINUED UNTIL CONSUMED (ASTM D1929) 3/23/2006 •-#110.1 wi van uUiiau VW's:Ucu) [Return] —4 1 F �+ - - CHARTER OAK SOFFIT REINFORCED LOCK B --) C A WAIL THICKNESS - 0.010• NOMINAL WEIGHT PER FOOT - 0.445 LE. DYERALL LENGTH -12' t 114" RAIL CENTERS - 18' A. INTERLOCKED PANEL WIDTH - 10.000 "± 0.030" B. FACE WIDTH - 3.000° ± 0.030" C. REVEAL GAP WIDTH - 0.300" ± 0.020" D. LOCK HEIGHT - 0.700" ±0.020" E. TOTAL PROFILE THICKNESS - 0.740" ±0.010" F. HOOK LENGTH r 0.460 "± 0.03D" G. NAILING STRIP WIDTH - 0.625" ± 0.030" H. NAIL SLOT OFFSET - 0.250 "± 0.020" Aside n America's Ibmes rage . or 5 http: / /intranet. alside. com /tssg/ SidingSpecifications /COSFT.HTML 3/23/2006 �naner uax oonu r v erucat owing ARCHITECTURAL SPECIFICATIONS GENERA', SPECIFICATIONS M s i de_® First On America's Homes ALSIDE PREMIUM VINYL SIDING CHARTER OAK REINFORCED LOCK PREMIUM VINYL SOFFIT/VERTICAL SIDING ALSIDE PREMIUM VINYL SOFFIT/VERTICAL SIDING CONFORMS TO ALL OF THE REQUIREMENTS ESTABLISHED IN THE MOST RECENT VERSION OF ASTM SPECIFICATION D4477, DEVELOPED COOPERATIVELY WITH THE INDUSTRY AND PUBLISHED BY THE AMERICAN SOCIETY FOR TESTING AND MATERIALS. ALSIDE MAINTAINS RIGOROUS PRODUCTION QUALITY CONTROL STANDARDS TO ASSURE THAT PREMIUM VINYL SOFFIT/VERTICAL SIDING WILL PERFORM AS EXPECTED FOR ITS INTENDED USE. MATERIALS PROPERTIES ALSIDE PREMIUM VINYL SOFFIT/VERTICAL SIDING IS PRODUCED FROM POLYVINYL CHLORIDE)(PVC) COMPOUNDS MEETING THE REQUIREMENTS OF ASTM D 4477 FOR COMPOUND CLASS NUMBER 2 MATERIALS. TYPICAL COMPOUND PROPERTIES IMPACT STRENGTH @ 74° F IMPACT STRENGTH @ 32° F TENSILE STRENGTH MODULUS OF ELASTICITY IN TENSION DEFLECTION TEMPERATURE UNDER LOAD TYPICAL SOFFIT/VERTICAL SIDING PROPERTIES LENGTH WIDTH THICKNESS WARP 3.86 ft.lbf/in of notch (ASTM D256) 2.4 ft.lbf/in of notch (ASTM D256) 5718 psi. (ASTM D638) 399,800 psi. (ASTM D638) 186.8° F (ASTM D648) 12 ft. ±'Ain. loin. ± 1/8 in. 0.042 in. nominal 0.0 in. (ASTM D3679) http: / /intranet.al side. com/ tssg /SidingSpecifications/COVert.HTML ragc 1 vi 3/23/2006 a.uattci van uUaatt i v ciut.at utulug HEAT SHRINKAGE IMPACT RESISTANCE WEATHERABILITY COEFFICIENT OF LINEAR EXPANSION GLOSS (75° GLOSSMETER) FIRE RESISTANCE PROPERTIES AVERAGE TIME OF BURNING AVERAGE EXTENT OF BURNING FLAME SPREAD SMOKE DENSITY IGNITION PROPERTIES CODE LISTINGS OTHER TESTING: UNDERWRITER'S LABORATORIES ® - FILE R14214 0.93% (ASTM D3679) 101 in-lb (ASTM D4226, PROC.A.H.25) NO SURFACE OR STRUCTURAL DEFECTS SUCH AS PEELING, CRACKING, CHIPPING, ETC. WHEN TESTED AS PRESCRIBED IN ASTM D3679. 3.53 X 10 - 5 in. /in. ° F (ASTM D696) 35° (ASTM D 3679) <5 sec. (ASTM D635) <5 mm. (ASTM D635) 15 (ASTM E84) >500 (ASTM E84) SELF IGNITION DID NOT OCCUR. AT 680° F, SAMPLE BEGAN TO SMOLDER AND CONTINUED UNTIL CONSUMED. (ASTM D 1929) ALSIDE PREMIUM VINYL SOFFITNERTICAL SIDING IS LISTED BY THE FOLLOWING CODE WRITING ORGANIZATIONS UNIFORM BUILDING CODE - ICBO EVALUATION SERVICES STANDARD BUILDING CODE - SBCCI PST & ESI NATIONAL BUILDING CODE - BOCA EVALUATION SERVICES FEDERAL HOUSING AUTHORITY - MEETS REQUIREMENTS ra6c L vi .3 http: / /intranet. alside. com /tssg/ SidingSpecifications /COVert.HTML 3/23/2006 ........... .... ay..... .... u•..a 1./auL1L5 Rturn] CHARTER OAK VERTICAL REINFORCED LOCK A B -•-I N C A. INTERLOCKED PANEL WIDTH - 10.000 "± 0.030" B. FACE WIDTH = 3.000" ± 0.030" C. REVEAL GAP WIDTH = 0.300" ± 0.020" D. LOCK HEIGHT = 0.700" ±0.020" E. TOTAL PROFILE THICKNESS = 0.740" ±0.010" F. HOOK LENGTH = 0.450 "± 0.030° G. NAILING STRIP WIDTH = 0.625° ± 0.030" H. NAIL SLOT OFFSET = 0.250 "± 0.020" ■ALLTHICKPIESS - tow NOMINAL WEIGHT PEA FOOT - 0,415 tss. OVERAU. LENGTH - 12t0't1i4' NAIL CENTERS - W L 0 -a•-I G .. First On America's Homes Cagy J 01 J http: / /intranet. alside. com/ tssg/ SidingSpecifications/COVert.HTML 3/23/2006 \.Laltc1 Va& AL t.lapuualu &mum* r asc 1 u1 Y GENERAL SPECIFICATIONS ciAk First On America's Haines ARCHITECTURAL SPECIFICATIONS ALSIDE PREMIUM VINYL SIDING CHARTER OAK XL CLAPBOARD SIDING ALSIDE PREMIUM VINYL SIDING CONFORMS TO ALL OF THE REQUIREMENTS ESTABLISHED IN MOST RECENT VERSION OF ASTM SPECIFICATION D3679, DEVELOPED COOPERATIVELY WITH THE INDUSTRY AND PUBLISHED BY THE AMERICAN SOCIETY FOR TESTING AND MATERIALS. ALSIDE MAINTAINS RIGOROUS PRODUCTION QUALITY CONTROL STANDARDS TO ASSURE THAT PREMIUM VINYL SIDING WILL PERFORM AS EXPECTED FOR ITS INTENDED USE. MATERIALS PROPERTIES ALSIDE PREMIUM VINYL SIDING IS PRODUCED FROM POLY(VINYL CHLORIDE)(PVC) COMPOUNDS MEETING THE REQUIREMENTS OF ASTM D 3679 FOR COMPOUND CLASS NUMBER 2 MATERIALS. TYPICAL COMPOUND PROPERTIES IMPACT STRENGTH @ 74° F IMPACT STRENGTH @ 32° F TENSILE STRENGTH MODULUS OF ELASTICITY IN TENSION DEFLECTION TEMPERATURE UNDER LOAD TYPICAL, SIDING PROPERTIES LENGTH WIDTH THICKNESS WARP 3.86 ft.lbf/in of notch (ASTM D256) 2.4 ft.lbf/in of notch (ASTM D256) 5718 psi. (ASTM D638) 399,800 psi. (ASTM D638) 186.8° F (ASTM D648) 16ft.8in.f' bin. 9 in. ±1 /8 in. 0.046 in. nominal 0.0 in. (ASTM D3679) http: / /intranet. alside. com /tssg/ SidingSpecifications /COXLCL.html 3/23/2006 %,tuutct vats AS. t,ittpuuaiu oiuutg HEAT SHRINKAGE IMPACT RESISTANCE WEATHERABILITY COEFFICIENT OF LINEAR EXPANSION GLOSS (75° GLOSSMETER) SURFACE DISTORTION CANTILEVER SAG ANGLED SAG CENTER SAG END SAG FIRE RESISTANCE PROPERTIES AVERAGE TIME OF BURNING AVERAGE EXTENT OF BURNING FLAME SPREAD SMOKE DENSITY IGNITION PROPERTIES CODE TISTINGS OTHER TESTING: 0.17% (ASTM D3679) 101 in -1b (ASTM D4226, PROC.A.H.25) NO SURFACE OR STRUCTURAL DEFECTS SUCH AS PEELING, CRACKING, CHIPPING, ETC. WHEN TESTED AS PRESCRIBED IN ASTM D3679. 3.53 X 10 - 5 in. /in. ° F (ASTM D696) 30° (ASTM D 3679) NO DISTORTION AT 120 ° F (ASTM D 3679) 13" WHEN CLAMPED W/72" OF THE PANEL OVERHANGING THE SUPPORT POINT 431/4" WITH FULCRUM POSITIONED 27" HORIZONTALLY AND 42" VERTICALLY FROM THE SUPPORT POINTS 21/4" WITH TEN FEET BETWEEN SUPPORT POINTS 431/4" WITH CENTER SUPPORT <5 sec. (ASTM D635) <5 mm. (ASTM D635) 15 (ASTM E84) >500 (ASTM E84) SELF IGNITION DID NOT OCCUR. AT 680° F, SAMPLE BEGAN TO SMOLDER AND CONTINUED UNTIL CONSUMED (ASTM D1929) ALSIDE PREMIUM VINYL SIDING IS LISTED BY THE FOLLOWING CODE WRITING ORGANIZATIONS UNIFORM BUILDING CODE - ICBO EVALUATION SERVICES STANDARD BUILDING CODE - SBCCI PST & ESI NATIONAL BUILDING CODE - BOCA EVALUATION SERVICES FEDERAL HOUSING AUTHORITY - MEETS REQUIREMENTS r agc c 01 "r http: / /intranet. alside. com /tssg/SidingSpeci fications /COXLCL.htm1 3/23/2006 t, ualldl Val. AL l-1 UlVVaiU J lulllg UNDERWRITERS LABORATORIES ® - FILE R14214 OAK X CLAPBOARD http: / /Intranet. alside. com /tssg/ SidingSpecifications /COXLCL.html . - r 3/23/2006 ciuci i.uun uuuuic Y 1/h t.,tapuuaiu ragc 1 ui 3 GENERAL SPECIFICATIONS CFirst On America's Homes ARCHITECTURAL SPECIFICATIONS ALSIDE PREMIUM VINYL SIDING CENTER LOCK DOUBLE 4%" SIDING ALSIDE PREMIUM VINYL SIDING CONFORMS TO ALL OF THE REQUIREMENTS ESTABLISHED IN THE MOST RECENT VERSION OF ASTM SPECIFICATION D3679, DEVELOPED COOPERATIVELY WITH THE INDUSTRY AND PUBLISHED BY THE AMERICAN SOCIETY FOR TESTING AND MATERIALS. ALSIDE MAINTAINS RIGOROUS PRODUCTION QUALITY CONTROL STANDARDS TO ASSURE THAT PREMIUM VINYL SIDING WILL PERFORM AS EXPECTED FOR ITS INTENDED USE. MATERIALS PROPERTIES ALSIDE PREMIUM VINYL SIDING IS PRODUCED FROM POLY(VINYL CHLORIDE)(PVC) COMPOUNDS MEETING THE REQUIREMENTS OF ASTM D 3679 FOR COMPOUND CLASS NUMBER 2 MATERIALS. TYPICAL COMPOUND PROPERTIES IMPACT STRENGTH @ 74° F IMPACT STRENGTH @ 32° F TENSILE STRENGTH MODULUS OF ELASTICITY IN TENSION DEFLECTION TEMPERATURE UNDER LOAD TYPICAL, SIDING PROPERTIES LENGTH WIDTH THICKNESS WARP 3.86 ft.lbf/in of notch (ASTM D256) 2.4 ft.lbf/in of notch (ASTM D256) 5718 psi. (ASTM D638) 399,800 psi. (ASTM D638) 186.8° F (ASTM D648) 12 ft. 1 in. ±1 /bin. 9 in. ± .030 in. 0.044 in. nominal 0.0 in. (ASTM D3679) http: / /intranet. alside. com/ tssg/ SidingSpecifications /CTRLKD4.HTML 3/23/2006 1iG11Ua LUUK LUUUIV Y 1/L ldapUU2UU rage L 1.11 J HEAT SHRINKAGE IMPACT RESISTANCE WEATHERABILITY COEFFICIENT OF LINEAR EXPANSION GLOSS (75° GLOSSMETER) SURFACE DISTORTION FIRE RESISTANCE PROPERTIES AVERAGE TIME OF BURNING AVERAGE EXTENT OF BURNING FLAME SPREAD SMOKE DENSITY IGNITION PROPERTIES CODE LISTINGS ALSIDE PREMIUM VINYL SIDING IS LISTED BY THE FOLLOWING CODE WRITING ORGANIZATIONS UNIFORM BUILDING CODE - ICBO EVALUATION SERVICES STANDARD BUILDING CODE - SBCCI PST & ESI NATIONAL BUILDING CODE - BOCA EVALUATION SERVICES FEDERAL HOUSING AUTHORITY - MEETS REQUIREMENTS OTHER TESTING: UNDERWRITER'S LABORATORIES ® - FILE R14214 http: / /intranet. alside. com/ tssg/ SidingSpecifications /CTRLKD4.HTML 0.93% (ASTM D3679) 101 in-lb (ASTM D4226, PROC.A.H.25) NO SURFACE OR STRUCTURAL DEFECTS SUCH AS PEELING, CRACKING, CHIPPING, ETC. WHEN TESTED AS PRESCRIBED IN ASTM D3679. 3.53 X 10 - 5 in. /in. ° F (ASTM D696) 25 °/35° (ASTM D 3679) NO DISTORTION AT 120° F (ASTM D 3679) <5 sec. (ASTM D635) <5 mm. (ASTM D635) 15 (ASTM E84) >500 (ASTM E84) SELF IGNITION DID NOT OCCUR. AT 680° F, SAMPLE BEGAN TO SMOLDER AND CONTINUED UNTIL CONSUMED (ASTM D1929) 3/23/2006 �enicr ;.uCC I /011010 air_, , iapnoaru htt intranet.alside. com/ tssg /SidingSpeciiicationsiCTRLKD4 1-117\ II, 1006 rreseIvaLlon uouoie 4 -1/L rremnlm vmyl outing GENERAL SPECIFICATIONS First On America's Hcnnes ARCHITECTURAL SPECIFICATIONS ALSIDE PREMIUM VINYL SIDING PRESERVATION DOUBLE 4 -1/2" SIDING ALSIDE PREMIUM VINYL SIDING CONFORMS TO ALL OF THE REQUIREMENTS ESTABLISHED IN THE MOST RECENT VERSION OF ASTM SPECIFICATION D3679, DEVELOPED COOPERATIVELY WITH THE INDUSTRY AND PUBLISHED BY THE AMERICAN SOCIETY FOR TESTING AND MATERIALS. ALSIDE MAINTAINS RIGOROUS PRODUCTION QUALITY CONTROL STANDARDS TO ASSURE THAT PREMIUM VINYL SIDING WILL PERFORM AS EXPECTED FOR ITS INTENDED USE. MATERIALS PROPERTIES rage 1 01 3 ALSIDE PREMIUM VINYL SIDING IS PRODUCED FROM POLYVINYL CHLORIDE)(PVC) COMPOUNDS MEETING THE REQUIREMENTS OF ASTM D 3679 FOR COMPOUND CLASS NUMBER 2 MATERIALS. TYPICAL COMPOUND PROPERTIES IMPACT STRENGTH @ 74° F IMPACT STRENGTH @ 32 F TENSILE STRENGTH MODULUS OF ELASTICITY IN TENSION DEFLECTION TEMPERATURE UNDER LOAD TYPICAL SIDING PROPERTIES LENGTH WIDTH THICKNESS WARP 3.86 ft.lbf/in of notch (ASTM D256) 2.4 ft.lbf/in of notch (ASTM D256) 5718 psi. (ASTM D638) 399,800 psi. (ASTM D638) 186.8° F (ASTM D648) 12 ft. 1 in. ± 0.25 in. 9 in. ± 0.030 in. 0.050 in. + 0.002 in. - 0.001 in. 0.0 in. (ASTM D3679) http: / /intranet. alside. com /tssg/ SidingSpecifications /PreservationCL.html 3/23/2006 r sv°Clvluluu LVUUlc Y - 1 /G rlcuu Wll v idyl OIUU% ragc z. to J HEAT SHRINKAGE IMPACT RESISTANCE WEATHERABILITY COEFFICIENT OF LINEAR EXPANSION GLOSS (75° GLOSSMETER) SURFACE DISTORTION FIRE RESISTANCE PROPERTIES AVERAGE TIME OF BURNING AVERAGE EXTENT OF BURNING FLAME SPREAD SMOKE DENSITY IGNITION PROPERTIES CODE LISTINGS OTHER TESTING: UNDERWRITER'S LABORATORIES ® - FILE R14214 0.17% (ASTM D3679) 101 in -lb (ASTM D4226, PROC.A.H.25) NO SURFACE OR STRUCTURAL DEFECTS SUCH AS PEELING, CRACKING, CHIPPING, ETC. WHEN TESTED AS PRESCRIBED IN ASTM D3679. 3.53 X 10 - 5 in. /in. ° F (ASTM D696) 30° (ASTM D 3679) NO DISTORTION AT 120 ° F (ASTM D 3679) <5 sec. (ASTM D635) <5 mm. (ASTM D635) 15 (ASTM E84) >500 (ASTM E84) SELF IGNITION DID NOT OCCUR. AT 680° F, SAMPLE BEGAN TO SMOLDER AND CONTINUED UNTIL CONSUMED. (ASTM D1929) ALSIDE PREMIUM VINYL SIDING IS LISTED BY THE FOLLOWING CODE WRITING ORGANIZATIONS UNIFORM BUILDING CODE - ICBO EVALUATION SERVICES STANDARD BUILDING CODE - SBCCI PST & ESI NATIONAL BUILDING CODE - BOCA EVALUATION SERVICES FEDERAL HOUSING AUTHORITY - MEETS REQUIREMENTS http: / /intranet. alside. com/ tssg/ SidingSpecifications /PreservationCL.html 3/23/2006 11GJGl VQLlVll LVUUW 't 1( 11C11111.1111 V 111)'1 Jilting [Return] f age J W J http: / /Intranet. alside. com/ tssg/ SidingSpecifications /PreservationCL html 3/23/2006 ✓vWY w IJYLLVY • •I LLY cis 13 1 J&115 GFNFRAL SPECIFICATIONS MATFRIAI S PROPERTIES TYPICAL, COMPOUND PROPERTIES IMPACT STRENGTH @ 74° F IMPACT STRENGTH ® 3r F TENSILE STRENGTH MODULUS OF ELASTICITY IN TENSION DEFLECTION TEMPERATURE UNDER LOAD TYPICAL VERTICAL SIDING PROPERTIES LENGTH WIDTH THICKNESS WARP ■ Illi On America's Hcxnes ARCHITECTURAL SPECIFICATIONS ALSIDE PREMIUM VINYL SIDING BOARD & BATTEN VERTICAL SIDING ALSIDE PREMIUM VINYL VERTICAL SIDING CONFORMS TO ALL OF THE REQUIREMENTS ESTABLISHED IN THE MOST RECENT VERSION OF ASTM SPECIFICATION D4477, DEVELOPED COOPERATIVELY WITH THE INDUSTRY AND PUBLISHED BY THE AMERICAN SOCIETY FOR TESTING AND MATERIALS. ALSIDE MAINTAINS RIGOROUS PRODUCTION QUALITY CONTROL STANDARDS TO ASSURE THAT PREMIUM VINYL VERTICAL SIDING WILL PERFORM AS EXPECTED FOR ITS INTENDED USE. ALSIDE PREMIUM VINYL VERTICAL SIDING IS PRODUCED FROM POLY(VINYL CHLORIDE)(PVC) COMPOUNDS MEETING THE REQUIREMENTS OF ASTM D 4477 FOR COMPOUND CLASS NUMBER 2 MATERIALS. 186.8° F (ASTM D648) http: / /intranet. alside. com/ tssg/SidingSpecificationsBB.HTML 3.86 ft.lbf/in of notch (ASTM D256) 2.4 ft.lbf/in of notch (ASTM D256) 5718 psi. (ASTM D638) 399,800 psi. (ASTM D638) 10 ft. ± 0.125 in. 7.0 in. ± 0.050 in. 0.050 in. + 0.002 in. - 0.001 in. 0.0 in. (ASTM D3679) rage 1 of s 3/23/2006 4.•••••••• • .......... ••1..1.116 HEAT SHRINKAGE IMPACT RESISTANCE WEATHERABILITY COEFFICIENT OF LINEAR EXPANSION GLOSS (7? GLOSSMETER) FIEFLRESISTANCF PROPERTIES AVERAGE TIME OF BURNING AVERAGE EXTENT OF BURNING FLAME SPREAD SMOKE DENSITY IGNITION PROPERTIES CODE LISTINGS 35° (ASTM D 3679) ALSIDE PREMIUM VINYL VERTICAL SIDING IS LISTED BY THE FOLLOWING CODE WRITING ORGANIZATIONS UNIFORM BUILDING CODE - ICBO EVALUATION SERVICES STANDARD BUILDING CODE - SBCCI PST & ESI NATIONAL BUILDING CODE - BOCA EVALUATION SERVICES FEDERAL HOUSING AUTHORITY - MEETS REQUIREMENTS OTHER TESTING: UNDERWRITER'S LABORATORIES ® - FILE R14214 0.93% (ASTM D3679) 101 in -lb (ASTM D4226, PROC.A.H.25) NO SURFACE OR STRUCTURAL DEFECTS SUCH AS PEELING, CRACKING, CHIPPING, ETC. WHEN TESTED AS PRESCRIBED IN ASTM D3679. 3.53 X 10 - 5 in. /in. ° F (ASTM D696) rage L 01J <5 sec. (ASTM D635) <5 mm. (ASTM D635) 15 (ASTM E84) >500 (ASTM E84) SELF IGNITION DID NOT OCCUR. AT 680° F, SAMPLE BEGAN TO SMOLDER AND CONTINUED UNTIL CONSUMED. (ASTM D1929) http: / /intranet. alside. com /tssg/SidingSpecificationsBB.HTML 3/23/2006 BOARD & \' -1■ C- 1--1 -0:122 DESH INTFRTOCKED PANE WIDTH 7,000 ± 0.050 B. PANEL WIDTP 8.336 ± (IWO 0. BIM WIDTH. .500 ± 0.070 9: BUTT TIEIGHT 0.520 ± 0.020 F HIM HOOK LENGTH 0,443 I+ 0,030 F. PROFILE 2IPAKI, :FIAT .028 C. WIISNCER 7.63 ± ,030 H. HANGER HE** 0.440 ± .030 I. NAIL SLOTS CENTER 0250 ± 0,22 J. NAIL SLOT HOI 0.156 X 0.070 WALL ;THICK EXPOSED =(L050 4-03)02 0,001' WALL THICKNESS RANGER -0.050 WE C-I-1/ PER FOOT -0.375 OVEN I. I ENGIN = 10' 1: C125 1 http://iniranct.alside.comitssgiSidingSpeciticationsiBB.HTMI. rift Or Amerial llomes k I 1 200( ........b 1 •vow• UIIVV111VQISV11 CALL 11V111G1 ASTM E84 SURFACE BURNING CHARACTERISTICS TEST DATA SHEET Client: ALSIDE Date & Time: 05 -25 -1995 14:51:57 Project Number: 99825 -214 Test Number. 2 Material Identification: RESIDENTIAL VINYL SIDING PANEL, 94V5CC 2 LENGTHWIDE INTERLOCKING PIECES, 12' FLAME (4 PIECES TOTAL IN TUNNEL) SUPPORTED BY CHICKEN WIRE AND RODS Test Red Specimen Oak. Time To Ignition (min:sec): 00:14 00:52 Time To Max Flame Spread (min:see): 04:12 Max. Flame Spread (ft): 2.4 Max. Temperature (Deg.F.): 483 Time To Max Temperature (min:sec) : 09:54 Time To 980 Degrees F (min:sec): Flame Spread x Tine Area (mingft): Smoke x Time Area (min *%S): Temperature x Tune Area (min'Deg.F): Unrounded Flame Spread Index: Unrounded Smoke Developed Index: Total Fuel Consumed (cubic feet): 45.10 Temperature X Time Area for GRC Board (min*Deg.F): 5196 Engineer: ETL Testing Laboratories FLAME SPREAD INDEX: _ 10 SMOKE DEVELOPED INDEX: 490 http: / /intranet. alside. com /tssg/Architectu ralSpecs/reports/et11995.htm FILE COPY Permit No. LONG, INTERIOR FACEEXPLOSED:i'Qni 01111581p • ;2t .1: n/a 20 476 4242 10.16 489.10 880 REVIEWED FOR CODE COMPLIANCE annonuco 9 ' MAY 12 2006 City Of Tukwila 111 ITLr1T!`!r_ !M iTcyfirk rage 1ot RECEIVED CITY OF TUKWILA APR 13 2706 PERMIT CENTER 3/23/ June 16, 2005 Mr. Dave Campbell, General Counsel Abide 3373 Stale Road C4"ryehuga Fits', OH. 44309 Dear Dave, PI � tD e. - rrts ..-. As you know, FM Global has been your pfoperty .insurance carrier for twenty years now. We know that Alside's supply centers store vinyl siding and accessories and also vinyl w+ntiows We-at at have not tested every one of your products, but we do consider your finished products to be Class 2 commodities for our insurance purposes.._ L.. We also know that it is your corporate practice to store your finished products in wire — mesh deck racking at heights of 10 feet in some instances, but not to exceed 25 feet in all others. Please let me know if you have any additional questions regarding your product classification or storage practices. ha REVIEWED F(3R Je ; .1 ovich COMPLINCE A ount Manager e pteonsrc0 MAY 12 2006 Factory Mutual Insurance Company Great Northern Corporate Center 25050 Country Club Boulevard, Suite 400 North Olmsted, OH 44070 USA T 216 362 4820 F: 216 362 4825 www.fmglobaLcom FILE COPY Per!n ?t No. RECEIVED CITY OF TUKWILA APR 1 3 7195 PERMIT CENTER Pag\-;1??32- December 5, 2005 Re: Material Safety Data Sheets (MSDS's) To Whom It May Concern: Pursuant to your recent request, we have enclosed a copy of an advisory letter regarding Material Safety Data Sheets. Please note that many building materials are "articles" and would not expose employees to health hazards under normal conditions of use. Alside Siding products, as well as Alside Vinyl Windows and Window Accessories, are articles and do not require Material Safety Data Sheets, as per the Code of Federal Regulations, 29CFR 1910.1200 (b)(6)(v) and defined in 29CFR 1910.1200 (c). Should you require any additional assistance, please contact me at 330/922 -2389. Sincerely, Nicholas D. Thompson, CSI Technical Service Representative Enc: Advisory Letter Circd. Federal Regulations 29CFR1910 TO OUR VALUED BUILDING PRODUCTS CUSTOMERS: Associated Materials Incorporated is committed to providing accurate health and safety information on the products that we manufacture or distribute. We have a program to continually review our products to determine which products require Material Safety Data Sheets (MSDS) and to revise our Material Safety Data Sheets to provide the most current information available. Most products manufactured by Associated Materials Incorporated are "articles" and would not expose employees to health hazards under normal conditions of use or in a foreseeable emergency. We do not provide Material Safety Data Sheets for these "articles ". Other products are not "articles" and must have a Material Safety Data Sheet, according to regulations of the Occupational Safety and Health Administration (OSHA). For all such items manufactured by Associated Materials Incorporated, a MSDS is prepared and provided to our distributors. When Associated Materials Incorporated distributes products made by others, we ensure that Material Safety Data Sheets, and updated information, are provided to other distributors and employers. As a retail distributor to commercial customers, we will provide a Material Safety Data Sheet upon request. We strive to improve the ways in which we communicate safety information and product safety information, so that it is clear and complete. Material Safety Data Sheets and safety information are under ongoing review and will be updated as needed. We appreciate your continued business and assure you that we will take the steps necessary to provide Material Safety Data Sheets where needed. NOTE: Material Safety Data Sheets, their need, and applicability are discussed in the Code of Federal Regulations, Title 29, Part 1019, Subpart Z, Section 1910.1200. 29cfr1910.1200(b) (1) This section requires chemical manufacturers or importers to assess the hazards of chemicals which they produce or import, and all employers to provide information to their employees about the hazardous chemicals to which they are exposed, by means of a hazard communication program, labels and other forms of warning, material safety data sheets, and information and training. In addition, this section requires distributors to transmit the required information to employers. (Employers who do not produce or import chemicals need only focus on those parts of this rule that deal with establishing a workplace program and communicating information to their workers. Appendix E of this section is a general guide for such employers to help them determine their compliance obligations under the rule). 29cfr1910.1200(b) (6) This section does not apply to: 29cfr1910.1200(b) (6) (v) Articles (as that term is defined in paragraph (c) of this section); 29cfr1910.1200(c) Definition. Article means a manufactured item other than a fluid or particle: (i) which is formed to a specific shape or design during manufacture; (ii) which has end use function(s) dependent on whole or in part upon its shape or design during end use; and (iii) which under normal conditions of use does not release more than very small quantities, e.g., minute or trace amounts of a hazardous chemical (as determined under paragraph (d) of this section), and does not pose a physical hazard or health risk to employees. C ISidelial First On America's Homes Alside Vinyl Siding, Soffit and Accessories Alside's vinyl siding, soffit and accessories are made. principally of the same PVC (polyvinyl chloride) resin compounds, meeting the established requirements of ASTM D3679 for compound class number 2 and 3. These materials are used primarily in exterior cladding applications. These products have been tested at Underwriters Laboratories, Inc. in accordance with ASTM Standard E84 - Test Method for Surface Burning Characteristics of Building Materials with the following results: (vinyl siding, soffit and accessories — standard colors) Flame Spread 15 Smoke Development over 500 (vinyl siding, soffit and accessories — architectural color collection) Flame Spread 20 Smoke Development over 500 dkiisidem First On Homes First On America's Homes TEST CRITERIA Impact Strength @74°F Impact Strength @32°F Tensile Strength Modulus of Elasticity Deflection Temperature tDenotes Average C. Fire Resistance Properties: Average Time of Burning Average Extent of Burning Flame Spread Spoke Density Ignition Properties 3773 STATE ROAD • P.O. BOX 2010 • AKRON. 01110 44309 • (330) 920 -1811 PART 2 PRODUCTS 2.01 Manufacturer A. Material to be supplied by Alside, Division of Associated Materials Incorporated, Cuyahoga Falls, Ohio (800)922 -6009 or otherwise approved as equal by the architect prior to the bid date. 2.02 Materials A. Vinyl siding shall conform to all of the requirements established by ASTM Specification D3679 -96, developed in cooperation with the industry and published by the American Society for Testing and Materials. Manufacturer Shall maintain rigorous production quality control standards to assure that Premium Vinyl Siding will perform as expected for its intended use. Vmyl siding shall be VSI certified B. Typical Conipound Properties - Vinyl siding is produced from Poly Vinyl Chloride (PVC) Compounds meeting the requirements of ASTM D3679 for compound class number 2 materials with the following manufacturing and product specifications: TYPICAL PROPERTIES 3.86 ft lb /in of notch (ASTM D256)t 2.4 ft lb /in of notch (ASTM D256)t 5718 psi (ASTM D638)t 399,800 psi (ASTM D638)t 186.8 °F (ASTM D648)t <5 sec (ASTM D635) <5mm (ASTM D635) 15 (ASTM E84) >500 (ASTM E84) Self Ignition did not occur. At 680T sample began to smolder and continued until consumed. (ASTM D1929) d o Fast O nAmerica's Homes November 28, 2005 RE: Alside Vinyl Siding, Soffit and Accessories To Whom It May Concern: 3773 STATE ROAD • P.O. BOX 2010 • AKRON, OHIO 44309 • (330) 929 -1811 Alside vinyl siding, soffit and accessories contains O% plasticizers. Should you have any questions or require additional information, feel free to contact me at (330)922 -2389. Sincerely, &kt.4 \ilr- Nicholas D. Thompson Technical Representative Me* RECYCLED tH[RYtL l.t Fran ' 111,T1 V Fullback - Insulated' Vinyl Siding - Features and Properties Page 1 of 3 Fullback Features & Properties Product Features Bask uses Vinyl siding backing, to Improve strength and thermal properties , Product attr1bUes and charectarlstcs 1 Expandable polystyrene (EPS) foam Insulation treated with **re retardant. Selection criteria • contains no FFCs, HC or formaidehyda • Nearly Identical coefficient of expansion as vinyl aiding. • Moisture parable (Fullback is not a vapor barrier). Applicable standards, related reijerences �• • ASTM 0238 Standard Test Method for Steady -Slate Thermal Periomprce Of Byliding. L • Assemblies by Means of a Guarded Hot Sox. • • ASTM C272 F r Standard Test Method for Water Absorption id Core Materials for Structure: Sandwich Cdnslxudions. • °? • ASTM C303 Standard Test Method for Dimensions end Density of Preformed Block- -Type Thermal Insulation. ' • ASTM C578 Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation. • ASTM 03679 - Standard Specification for Rigid Poly (Vinyl Chloride) (PVC) Siding. • ASTM E98 -Standard Test Method for Heat and Visible Smoke Release Rates for Products. ` • UL Classified." 1 • a�l biding, and Ofotection Mtcunns • , ThermoWat 100.ecpitlrefoot mi. m} • EassPaat: 2 � - p cartons. , T • do cad be stored outdoors. , • Weigh tom f FWlbOdc bags to preNent movement due b wind. i • • WariaMys lifetime, on stnictural integrdy and thermal performance. Availability Local dealers. Cost • Contact local dealers far pricing. • Tits proe pays for itself Sayegh savkgs in healing costs by Increasing the Insulating val x of the wall, as Weil es reducing the Incidence of Mechanical damage by proViding additional ' structural support to the awing penis. CITY OF RECEIVED • product Properties. . . APR 1 3 2006 Matarlai; compositi m, and design • Material: Expanded polystyrene (EPS), boated with lire retardant PERMIT CENTER • Density:1.016rcu hroirl /nmlresskie oam.com/ptofes$ionalaffea r®s:php tt t'd 2260££101 • LI9tSLS902 - 1) Press Pa - r zt x r7 x g4('1,4its) FILE po...r,rt No. CODE CO PIN CE eoloo ucp MAY 22006 Oily Of uk*il&; RIITI IITN nnngTfN cl ': 301thiszk ad th 9002- ▪ Fullback - Insulated Vinyl Siding - Features and Properties • Flame spread / smoke developed: A / 175. • Water Abeor{ition: leas than 4% by volume. • Thermal Expanaton:.000035 IndVinch/deg F (.000083 mm/mm•deg C). • Insulating Values: Siding Profile 373 ( D-4" (100mm) ' 3.3 (0.60) D-4.5" (112mm) 3.7 (0.70) 0.5' (125mm) 3.4 (0.74) D-4" (100mm) clutch Lap 3.6 0.67) D-4.5" (112mrrr) Dutch Lap 4.0 (0.70) D - 5'(125nnn) L;p 4.0 76) Trip14 3" (75mm 3,7 0 N, • FOOmn9 1 Snaps, ma rind dimensions , • Skiing Profiles; To Match siding manufacture(* prole*. I I • Starter Sip'. BesyStert® strip ensures sufficient speed between the siding panel and the Sal substrate to accommodate ThermoWell panels. • Corner Posts: FasyPest® Inserts fit behind aiding comer posts. i Preapproved siding manufacturers: • Alcoa Building Product* • Abide Vinyl Siding • CertainTped • "Crane PerforjnanceSiding • Oentek Building Products, • Heartland • Mastic • Napco • Norandex Inc. • Owens • • �rce Mdterials CCarporati % • Roiiex dorpoyton tan' n' Ming Products e ' Vertomf, Ink: • Vytec i • Wo vertne vinyl Siding Manufacturing size tolerance: • Thickness: +/ -1/32 Inch (0.8mm). • Width: +/- 1/16 Inch (14mm). • Length: M- M16 Inch (4.6mm). I ; Colors and texbrrss Cam. Product Placement Panel Sizes: Fullback: , • Length: 4 ft (1200mm) k)ng. • Width: 27 to (675 to 800mm) depending on profile. EbsyPbit 45 Mch (1200mm) long. EasyStart: k 6 in ( ) lo^g. In$taIIeton, erection Install FasyStaf starter strip to siding manufacturer's instructions. Starter strip Is required to s httn: // progressive foam .com /professionals/features.php TI/2 69L226e£E:01 LT9TSLS902 Page 2 of 3 3/22/06 30ISbti:1a4 at:ST 9002- 22 -2kiN Fullback - Insulated Vinyl Siding - Features and Propertics siding a sufficient distance from the wall to allow insertion of Fullback panels. Allow minimum 311, inch (gmm) space between starter rep and adjoining skiing accessories Install Easyfost Inserts undervinyl siding comer poets: Instal vinyl siding In swordanoe with eking manufactures instructions, Inserting Fullback Is behind each course immediately prior to nailing. Nail siding in position through the Fullback , il5 behind. Cutfulibeck panels using a sharp, thin -blade knife. Butt adjoining Failbacktpanals together leaving so gap (panels compress suRidendyto absorb expansion withhjut buckling). Corporate Idertpficatlon Progressive Fein Technologies. Inc. 8753 Chestnut Ridge Road Beach City. 01144608 Tel: 330,756,3200 Fax: 330.756.3706 Toll Free: 1800;860.3626 Ea!: klfoCprdgrossryefoam,00m Website:hthg10r .tu.Mbagk;eom Technical $en4ces Available ' Field Installatorj technical dupport Installer training! Classification and Filing Mastarformet: 07469 - Siding Insulation UNFonnat 82010 - Exterior Wails I bttp : / /progressivefoam.com/pro fessionals/features.php TT/£"d 8b9L 'E:OL LT9TSLS902 F Progressive Foem Technologies. inn. 8753 Chestnut Nkee Rd Roach City, Si 4160e 1.800 Be , 326 Page 3 of 3 3/22/06 30IS Pd:410SA 8T:ST 96132 -22-W4 F ULaL1.4 .•Y , t v r t y_ •rot ; F rim CJ!tevr% a flail ■A!K Fullback - Insulated Vinyl Siding - Fullback Performs well M fires Page 1 of 2 Grads 66 ' Nanfnal Density • ldaxbimuin Thlekness Inc =- • 1.0 1.0 1.o htto:// vrmtressivefoam .com/professionals/tech/firc.php TT/tr'd 8t+91 260£ .01 1T9TSLS902 Atio l ri s sun RPck tn chart ' • Fullback Performs well In fires The Fullback Thermal Support System was designed to perform well in lire situations. Extensi tests by independent laboratories confirm exaedant performance when exterior wads contairib Fullback are sxposed to a radiant heat source (as from a nearby burning building) and from op4n flame. The expanded poly$tyrene used in our thermal support system is manufactured containing a fire retardant. This greatly reduces the products contribution to a fire. In adddion, the Marmot support system completely Els the hodew void riat exists behind '. conventional vinyl and aluminum siding products. Since there are no sir pockets, the thermal support systeni'completely eliminates the 'chimney effect' that can contribute to the tlammabldjy,of oth erSing systems. (, . sai mess and sags eXbOSedild aw from tie mune of heat ' Nab. . rt I Pismo Retardant Fullback Thermal Support Systems ere molded using only' modified grades of expandable polystyrene and therefore contains flame retardant designed U decressb ftemmablllty due 10 accidental Ignition from a small flame source. The expanded polystyrene manufactured tram th rae materiels is routinely tested under UL specifications to insure Mat that m.et or exceed the requirements of the nation's building codes and appkwble mdustrlal, artiest and slate requirements. Flame Spread end Smoke developed Ratings . The national binding codes require foam plastic Insulation used in the walls of residential construction to have a flame spread of not more than 75 and a smoke developed of not mom en 450. Huntsman Chemical torperadon EPS grade 54 and 86 beads used to manufacture the Futibalc tamely of products produce the following ASTM E-84 test results. 145 175 2.0 10 120 2.0 2 15 125 2.0 4 20 165 2.0 ' S 20 155 Grade 54 Nominal Density Maximum filcknes. Flsmetpread rating Smdke- Developed ing st nches FS SD 11 1 5 40 1.0 2 5 100 1.0 4 5 160 1.0 5 6 200 1.5 1 5 110 1.5 2 5 130 1.5 . 4 6 145 1.5 6 5 145 1.75 1 b 70; 3/22/06 30ISd:I.O 4 8T:ST 9802- 22-mew 41I/All "I_rrO.: .II:M F 2 v - F S. A 3 t L 6 A[ K. Fullback - Insulated Vinyl Siding - Fullback Performs well in fires Page 1 of 2 1, : r. BOok to chart 'r • ' r II Or: i . ,� :� pa' 'we F'utnfsck Performs wall In fires i The Fullback *ierma] Suppat5ystem was designed to perform well In are tis:ations. Esoanaivl fasts by Independent Iabdraloiles COMM exceastd performance when exterior walls contain, Fullback are e$poeed to 0 iediant heat source (as Spin a nearby burning building) and from opt n , flame. The expanded poI Styrene used hour thermal support system manufactured contain lg 0 fire retardant. T rs greatly reduces the producrt conelbuaon to a Bre. I In addition, the Ihemml support system Completely tats the hollow irold fist exists behind • conventional vinyl and aluminum siding products. Slake there ere no sir pockets, the thermal 'i support system completely eliminates the *chimney effect* that can contribute to the flammablli♦y of other siding systems. When exposed b an open flame or a high radiant heat source, the EPS gimpy melts and laps away from the source of heat Remo Retardant Fullback Magna: onymoQIIedl ar expandable . po ne a apnatns flame retard* designed to deMessellammabaaydue b tai Ignition troth a small flame Wogs florpanmd 9PhiraOlted ttaml � N ro etpt�tat" ' ' f0 insure 1+10 . or exceed Iremarts c4 the nation's .bult % codes and tlx Shut. Pod state 111191. *PIT it 21. I i The nation:al Miming codee'esquIre foam plastic Insulation 'used In the wake 01 residential consbuction to have a flame sensed of not more Man 75 and a smoke Toped of not more Vien Huntsman Chetnical Cerebration EPS grade 54 and 88 beads used to manufacture the Fuebak - far* of produets produce die following ASTICE teSt Mutt , Grade 86 Nominal Venally 1.0 1.0 1.0 1.0 2.0 2.0 2.0 2.0 Miaxirnum Thickness "Rana-spiead Sting Smoka4evotoeor Pa Ilnchas) • (FM) (SOD 1 • . . - - 10 145 2 10 175 5. 15. • ; ;120. �1 6. ii. 125 1651 igg; • - 165' htto : //prq¢ ssive Ara. D/Drofe630nals/tecb/fitc.PhP TT/b'd :q.l. . , r i'T9SSL r JJ k ing Grade 54 i Nominal Docility Maximum Thickness ' Flarne.t prsad rating Smoke-Developed aging 5b nches FS S0 1.r r 1 5 40 10 2 5 k 1 100 1.0 I 4 5 160 1.0 r. 5 6 200 1.5 1 6 110 1.5 2 5 130 1.5 4 5 145' 1.6 5 5 . 145 1.75 1 5 70 3/22/06 �5is :tI ts :9aez -dd.] Fullback - Insulated Vinyl Siding - Fullback Performs well in fires 1.75 1.75 1.75 Fullback Fl a nMabilhy Characteristics terg 2 4 5 5 5 200 200 ;200 '165 (75'Cl 720'F (380t) 880'F(470`0 Prukossive Foan( Technologies, kit 0753 Chestnut Ridge Rd Beach Chy. OK 44808.1100.8601en Recommended!max'mum Otte temperature Melting point -M a thenmoplasdc. polystyrene does not exhibit a true melting point. It will begin b soften at about 21YF mot) and, as rare heat Is applied, melting occurs. Flash tgninon temperature -The lowest Initial temperature of sir passing around a molded sample of EPS at which a sufficient amount of combustible gas is evolved t0 be ignited (ASTM 01929). Self ignition temmperature - The lowest initial temperature of air paseiing around the specimen M which, in the absence of an Ignition source, the self-heating properties of Fullback lead b ignition or ignition occurs of itself. (ASTM 01029) Thermal Santa The terra " henitat banter refers to a fire resistant covering or coating which separates ESP the building interior. Common* used thermal barriers, altaubject to building'code approval, gypsum or cement plasterd, pertte board, spray $rpaed-0stlubse. mineral trier or gypsum and select s. For your guidance, model blinding codes often pacify Zenner barriers provide 15 min of protection in a fire. b all cases, design and instigation should comply current building requirements. r , Combustibility Fullback Them al Support materlhl pars must be considered combustible when directly I e,a osed tonne of sufficient Intensty and heat. Tfidrefore, neither should be stored nor installed near open flame or 14niton eoWCes. n ids mils, doh 11 Page 2 of 2 htt&/ proaressivefoam .controfessionals/toelt/Sre.Php 3/22/06 TTeS'd Bb91.2260££r01 hL29TSLS902 - 30IS18410214 8T.ST "9082 -22 -MAW Foodaervice and Food Packaging Building Products egg Packaging Building Products >'Residential > Siding Underlayment > GreenGuard® Fanfold Siding Underlayment > greenGuard® $P Siding Underlayment > GreenGuard® XP14 Siding Underlay R.xSOft. - Fanfold ■ GreenGuard® XP14 Wing underlayment = 1/41n. x4 ft. x .ems I r ,. In residing I 7 �� , aPplication5 GreenGuard® 4t XP14 is - j 3 • : _ installed over the old wood siding. By Installing GreenGuard® Underlaymeht over the old' siding, a 'smooth I'eVel installation surface clan be achie red. GreenGuard® XP14 Skiing Underlayment is our "best" value 1/4" thick Fanfold Siding Underlayment. It is made of Extruded Polystyrene foam (XPS) with extra tough , flexible plastic facers on both sides, perfelated to II w moistdre'vapor to escape. The XP series feature? the advanced cut- and -fold hinge for the best layflar iterformancJ. f his product easily bends around comers, with e *Cetledt'te514tance wracking, denting and tearing. One side Is printed with grid lines for easy' alignmlent and hutting. Ali Of these features combine for the fastest, easiest installation available. GreenGuard® XP14 Sk1(ng.Underlayhierlt provides a Al' k 50' continbous air and moisture bdrrier and provides the low moisture absorption that is typical of XPS. (Also available as FP series, with a perforated reflective facer on one side for enhanced thermal performance under recommended installation guidelines.) Nut 4- 617e q Xbt Name 1 1 GreenGuard® XP14 Siding Underlayment - .1/4 In. x 4 R. x 50 ft. - Fantail For more InforWlation on specific product recommendations an ant - 1/4 In. x 4 Pege 1of2 -Product Prop a ties - Value' ' . AsTM - CS1e 075• F Mean Temperature (•P- ? -New) Nominal Thickness (incaos) 1/4 -inch ASTM -12 1777 Water Vapor Transmission Rate (g/ma/24 hrs) AVM . E 96, Proc. A Fire Characteristics' ASTM • a 84 / UL 723 (Flame Spread/Smoke Oevelo Water Absorption , AST11 - C 272 (max, % by Volume) Squares per Bundle s per Pallet Pallets sie "per ` aek . • 1lC1/41r9 St. Fanfold l:o ' d) 1.7 25/250 2.0 2.0 90.0 SKU XP14 limitations, 'radon htm:/%o activoartners .uactiv.com/productcataleg/ Rooms/ DisplayPages /LayoutInitiatVroduct -... '3/22/06 TTi9'd 6b9L2260££.O1 LT9TSLS902 BOISle :Mid 6T •ST 9002 -22 -Mi14 contact your PACTIV Building Products Representat 1- 800 -241 -4402 Or, Click !! g to fill out our on -line Information request brm. t Specimens are aged and tested In accordance with the FTC 'R -value Rule' (16 CFR, Part 460). 2 Those numerical flame spread and smoke ratings are not intended to reiflect hazards presented this material under actual fire conditions. Cpre only data. I These products ;Mould not be used,sp an exposed interior surface M buildings where people are, mper� to be pre An approved fire . protection barrier, such as %' gypsum wallboard or equivaientmaterial must be ad to separate foam Mettle lnsulatioi i from the Interior of such buildings. Applicable he and buntline codes must be lb Slncc foam sheathings building codes. All assemblies should be evaluated for effectiveness and location of vapor retarders to avoid coed damage to structures (see ASHRAE Handbook of Fundamental$). 'cation and subsequent Warning: Foam: :,plastic Insulation will Ignite If exposed to fire of sufficient heat and Intensity, t foam Insulation from exposure to open flame or other Ignition sources during shipment, storage, and Installation. 1 Storage and Mdndiaap: Whon stored outdoors, all material Mould be Protected from exposure to beet sunlight using an opaque light - colored tarp or the original packaging. Material that has been unwrapped should be refully rewrapped. Pactiv Building * believes the information and recommendations herein to be accurate and Pliable. However, since use conditions $e not within lidcontroi, Partly does not guarantee results hoe use of such produc s or other Information herein and dlhclalms all IWblity from any resulting damage or loss. NO WARRANTY, EXPRESS OR IMPUED, IS GIVEN AS TO THE MERCHANrABILTrY, FITNESS FOR PA TICUTAR PURPOSE, OR OTHERWISE WITH RESPECT TO THE PRODUCTS REFERRED TO. Page 2 of 2 http : / /pactivpartner .pactiv.gom/productcatalog/ Rooms/ DisplayPagcs /Layoutinitiarkkoduct=... 3/22/06 TS'L'd 2260££ :O1 LT9TSLS962 30ITtJ:I.U8J 6T:ST 9062- 22 -211W PAGTI :.a ^ ?" 'F(3r, '",c'.r;, Foadseraice and Paelenlging Building Products *gg Packaging Building Products > Residential > Siding Underlayment > GreenGuard90 Fanfold Siding Underlayment > GreenGuard® XP Siding Underlayment > GreenGuerdS )(PP32 Siding tinder% ft. x 50 It. - Fanfold, Meek .1 -side GreenGuard® XFP38 Siding Underlayment - 3/8 in. x 4 ft. x -10 ft. - Fanfold, Reflective 1 -side L C Name GreenGua ® XFP38 Siding Underlayment - 3/8 In. x 4 ft. x 50 ft. - Fanf 1d, Reflective 1 -side Greeneis c( srtfbdtf'teyt In residing applications GreenGuard® XFP38 Is installed , . _ f over the old wood ' . siding: Sy instanlM'g undertayment over th&oid Siding Installa'tibh surface tan be achlevtA: GreenGuard® XFP38 Siding Underlayment Is our "best" value 3/8" thick Fanfold Siding Underlayment with a reflett)ve facer on one side for improved thermal performance. It is made of Extruded Polystyrene kern (XPS) with flexible plastic facers on both skips; that Is perforated to alidVt for ' • moisture vapor to escape. The XFP series features ' the advanced cut- ancl4fold hinge for the best LaVflat performance for the easiest installation available. This product easily bends around corners, with excellent resistance to cracking, denting and tearing. One side .is !prInted With grid, lines for ,alignment and . cutting. GreenGuar ® XFP38 Siding Underlayment provides a 4' x 50' ntlnuous air and moisture barrier arid provides,th low m0l*ture absorption typical eftPS. 1 Specimens ai c aged and tested In accordance with the FTC It-value Rub' (16 CPR, Part 460). Page 1 of 2 )tlMt -3/6 in. x 4 Produ 3 Properties R- Values 3.6 AST! - C 51e 075° F Mean Tempera ire VFelt h /atu) +Khes) 3/8- Nominal Thickness Arm 0 1777 i Water Vapor Transitiisslon Rate (g/ma/24 his) , { . ASTM - E 96, Proc. A Fire Characteristics ASTM - E 84 / UL 723 i (Flame Spread/Smoke bevelopady Water Absorption ASTM - t.272 (mx .% Squafes per 6u ndl � Square §per Pallet Pallets per Truck n 0 2.0 60.0 15 For more Information en specific product recommendations and 1 fnitatIons, contac PACTIV Building Products Representative , 1- 800 -241 -4402 Or, click to fill out our on -line information req lest form. httn•// nnetivnarme mactivcom/nroductcatalog/ Roo) ns/ DispiayPagcs /Layoutlnitial'„Ptoduct 3/22/06 11'B'd 8b9L2260££:01 LT912LS902 + 30I9lli:kL2f4 6T.ST 9002 -22 -ass Page 2 of 2 System *.valued ere calculated In a cCordanee whh Hs `ASHRAE Handbook of Fundamentals" usidp' j } re uniform pp de spate. The R -valde at thls product It/stalled Without' a lair Spate le #S. ` . ... " - I z These numerical Name spread and smoke ratings are not Intended to reflect hazards presented by this material under ach conditions. Cole only data. These products should not b$ used as an exposed Interior surface In buildings where people are expected to be present. An fire protection barrier, Such t4s K• gypsum wallboard or equivalent material must be used to separa e foam OHMIC IosulatIor Interior of such buildings. Applicable fire and building codes must be foaowed. Since foam sheathings are nenstructural, they must be installed over adequately braced framing In accordance with local h codes. All assemblies should be evaluated for effectiveness and location of vapor retarders to avoid conden lotion and subsequent c structures (sea A$HRAE Handbook of Fundamentals). 1j Warning: Foam plastic ksufatIon will Ignite If exposed to fire of sufncknt heat and intensity. Protay teem Insulation from e to open fame or other ignition sources during shipment, stonige, and instelNtbn, Storage and Handling: When stored outdoors, all material should be protected from exposure to s lrect sunlight usino an C tight-colored tarp or the original packaging. Material that has been unwrapped should be carefully 'd Pactly Building Prpducts believes the lnfgrmatlon retommendadona�reln to be aciculate and However, lento u conditions are net within Is control, Iatfhd does t guarantee multi from use of such products or t lta i ikmtatloii berek all b ddsdalms aabt wtfran any routing. damaged 4bsa. N I I, ' NO WARRANTY, EXPRESS OR IMPLIED, IS DIVER AS TO THE MERCHANTABIUTV, FITNESS PPR PM CU AR :PURPOSE; OR OTHERWISE WIT4 RESPECT TO THE PRODUCTS REFERRED TO. I http:// pactivpartutrs. pacdv. com/ productcatalog/ Rooms/DisplayPagcs/Layoutlnitial. ' coduct -... 3/22/06 TI/6'd Str9L2260E'£:01 LT9TSLS9@2 3QIS0.ia4.02.0 90@2- 22 -&t4 i-1 Pn TIV 1, c`% Foodservice and Food Packaging Building Products Itgg Packaging > .., > GreenGuard® RainDrop® Housewrep - 9 ft. x 150 R. Roll 9 'x4 . GreenGuafd® Rainurop® Housewrap - 9 ft. x 150 ft. Roll New apd Innovative! GreenGuard® RainDrop® approaches me ' the area of '. inolstta management in two ways. First, as a barrier, It has typical housewrap moisture 'and air penetration resistance, But, It Is unique lh that It also 'designed as a drainage plant. Whet siding Is install&d l aver GreenGuard®ia RainDrop®, channels remain fbr'water to 'drain aWarfrom the surface and, with the water gone the surface moisture dissipates through nOrmal drying by evaporation New GreenGuard® RalnDrop® Is a woven, peiforpted'wrap that provides exceptional tear resistance a}proaching that of dar "orlglhaf green tough Stuff" it • " GreenGuard® Lassie Wrap. in'addititfi4;' GreenGuard® RainOrop®i breathes to allow moisture veor to escape from the wall cavity. The 9' x 15d' roll Ia a' good mix between lightweight find minimal roll changes. Bath roll weighs approximately 20 pounds. Use GreenGuard® T255UL Contractor Tape with this product for best tape adhesion to the uneven surlbce. Name GreenGuard® RalnDrop® Housewrap - 9 ft. x 150 ft. ikoll Product Terlsile,Strengthl MYNA- D 662 - ,, Water Resistances Omuta) A3TM - 0 779 Trapezoid Tearing' Strength' abs./In.,MO/rD) AS174 - D 1117 Water Vapor Permeance (Fsrm) 10 ASTM • 996, Proc. A (75 °F, 50 %R.H.) Water Vapor Transmission Rate (g/m tin) ASTM • E 96, Proc. A Weight • 05. /1000 sq. R.) A511 -0 3776 Rolls per Pallet Pallet Size Pallets per Truck Burst Strength (psi) ASTM. -D751 Fire Characteristics? PSTMMJJ.. e 8 (game Spree d /Smoke Dever d) 4 Nominal ), $gGBrG p`eel :n4 Page t of 2 Properties ' 56 /30Ibs, /Ir al >.60 25/41 Ibsfir 73.0 19.0 155 psi • 0/15 Login I o r 015 t. 1350 40 43 In x 109 1 20 F r For more htformation on specific product recommepdations and limitations; conta PACTiv'Btliiding Products Representative. http:// paclivpartners .pactiv.eom/productcatalog/ Rooms/ DisplaYFages /LayoutInitial?Praduet =... 3/22/06 IT/OT's 8t.9L2260££:01 LT9TSLS902 30IS1U:4t21d 02•ST 9002 -22 -8M TT/TT'd 1 Machine ThreCttert/Cross Direction a These numerical flame spniad and smoke ratings are not intended to reflect haiards presented condltiOns. 3 The model building code agendas (BOCA, ICBO, and sseco anew ter water resistance testing In coordance with either A MTCC-127. Typically, woven housewraPs Ore tested In accordance with ASTM 0779, while norw-wovin housewrePS are tests accordance with AATCC-127. 4 In this pardculpr test method MD and TD designations represent the orientation In which the test the opposite direction. Therefore, the actual tear strength for MD and PM are reversed. CemPlion0a: HUD/FHA DU-13 Equivalent to Glide P Paper, Type 15, ASTM E 1677 Type 1 (S Systems) ASTM ti 226. Type 1 (Spedflcatlon for Pelt Building Paper/Roofing Paper). WARNING: Like ntost commerdally available plastic housewrap material, GreenGuard Housewraps exposed to Borne or other ignition sources. Pactiv Building FrOducts berkives the Information and reconmendadons herein to be accurate and are not within Its Control, PactIv dots not guarantee results from use of such products or other info from any resulting damage or loss. ; • • . P40 WARRANTY, fiXPRESS OR IMPLIED, IS gavels As To THE MERCHANTABILITY, FThiNESS POI( IM ; WITH RESPECT TO THE PRODUCSTB falleititEn to. , • , 1 t pi. . •1•- I! ; i • , . A 1-800-241-4402 Or, clicklmu to fill out our onallni information req Mit form. • tr. Page 2 of 2 s o ' thb meted& under acb. amples were taken with clficatien for Ale Retard( e combustible and shot liable. However, since u nation herein and discla Cul.AR PURPOSE, OR . 1 ;4;1' '4 to. 4 http://pactivpartners.pactiv.com/pmductcataloWRooms/DisplayPages/LayoutinitialWtoduct=... 3/22/06 W9/226022.01 LIgisissee 331Sii:W08.4 02.ST [ 9002-22-8M IF 1 4 • 11 -06 -2007 MICHAEL O'BRIEN 5837 221 PL S ISSAQUAH WA 98027 RE: Permit No.1206 -132 6701 S GLACIER ST TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be In wrtinn and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 12/18/2007 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, xc: Permit File No. D06 -132 Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 -431 -3670 • Fax: 206-431-3665 06-04 -2007 MICHAEL OBRIEN 5837 221 PL S ISSAQUAH WA 98027 RE: Permit No. D06 -132 6701 S GLACIER ST TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a f:mal inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not conunenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in wrttlne and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 07/25/2007 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, er Marshall, Permit Technician xc: Perna File No. D06 -132 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206- 431 -3665 01-02 -2007 MICHAEL O'BRIEN 5837 221 PL S ISSAQUAH WA 98027 RE: Permit No. D06 -132 6701 S GLACIER ST TUKW Dear Permit Holder. In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Pa the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such pennit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206-431 -2451 to schedule for the next or final inspection This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be bt writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 02/05/2007 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, xc: Permit File No. D06-132 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206 - 431 -3665 November 21, 2006 Craig Christensen Alside Supply Center 601 S Glacier St Tukwila WA 98188 RE: Request for Extension Development Permit No.,D06 -131 Alside — 601 S Glacier St Dear Mr. Christensen: This letter is in response to your written request for an extension to Permit No. D06 -132. The Building Official has reviewed your letter and considered your request to extend the above referenced permit. The City of Tukwila Building Division will be extending the expiration date of your permit 90 days from the date of your request (through February 2, 2007). If you should have any questions, please contact our office at (206) 431 -3670. Sincerely, shall it�7 ecllnician File: Permit No. D06 -132 City of Tukwila AkikcM Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director P:Vennifer%Extereion Lettcn\Permits \D06-132 Permit Extemion.doc Page 1 of 1 jem 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 -431 -3670 • Fax: 206 -431 -3665 8701 South Glacier St. Tukwila WA • 98188.425- 2914181 • Fax: 4252914185 • 800- 778 -2323 114 7 -2006 City of Tukwila: Department of Community Development 6300 Southcenter Blvd Suite#100 Tukwila, WA 98188 Dear City of Tukwila: Subject : Permit # D06 -132 We request an extension of the time given us to complete necessary work. The egress lighting installed requires additional lights and the contractor is not available to complete the work until December. We request a 90 day extension to allow time for the work to be completed. Thank you for your consideration. JAG \term ctet4 oft peie /1 -13 -00 Sincerely, C _ ig Christensen Operations Manager Alside RECEIVED NOV 0 9 2006 DE VELOPMENT 6-i ` H 12-O 1C r n .1110 RECYCLED 10 -03 -2006 MICHAEL O'BRIEN 5837 221 PL S ISSAQUAH WA 98027 RE: Permit No. D06 -132 6701 S GLACIER ST TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days front the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or fast inspection;: or if . the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 11/14/2006, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, sc: Permit File No. D06 -132 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 -431 -3670 • Fax: 206 -431 -3665 May 4, 2006 Michael O'Brien 5837 221 P1 SE Issaquah, WA 98027 RE: CORRECTION LETTER #1 Development Permit Application Number D06 -132 Alside — 6701 S Glacier St Dear Mr. O'Brien: This letter is to inform you of corrections that must be addressed before your development permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building and Department. At this time the Fire, Planning, and Public Works Departments have no comments. Buildine Department: Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 433 -7165. encl File No. D06 -132 City of Tukwila Department of Community Development Steve Lancaster, Director P:VennifenCorrection Letters \2006'D06 -132 Correction Ltr #I.DOC jem Ken Nelsen, at 206 431 -3677, if you have questions regarding the attached memo. Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431.3690 • Fax: 206-431-3665 Building Division Review Memo Date: April 24, 2006 Project Name: Alside, permit applications Application #: D06 -132 Plan Reviewer. Ken Nelsen, Senior Plans Examiner No further comments at this time. Tukwila Building Division Ken Nelsen, Sr. Plan Examiner An initial architectural Building Division plan review has been conducted on the subject permit application. Please address the following comments with revised plans and /or other applicable documentation. 1. General Notes on the Engineering plan sheet prepared by Seizmic Material Handling Engineering, correctly references the design criteria using the 2003 IBC. However, note number 5 references anchor Ramset thruboft ICC evaluation report number ER -1372. The noted ER report was approved under the old UBC and is no longer applicable for the "no special inspection" also shown in note number 6. Provide an updated anchor bolt ER report to the required anchor application, or provide general notes requiring special inspection of the bolts. 2. The installation of the new rack storage layout requires that a new Egress Illumination path must be identified on the plans showing compliance with I.B.C. Section 1006. The intended egress path may be identified as a single illuminated route of travel between the required exterior exit access doors. Additionally, the performance of the required illumination system described in I.B.C. Section 1006.4 must be specified in the general notes or otherwise shown on the plans. ACTIVITY NUMBER: D06 -132 DATE: 05 -17 -06 PROJECT NAME: ALSIDE SITE ADDRESS: 6701 S GLACIER ST Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision# 1 'BEFORE' Permit Issued DEPARTMENTS: g (- t Building Division NI PERMIT COOrIi, ',0r r �, PLAN REVIEW /ROUTING SLIP Fire Prevention Public Works ❑ Structural ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ Comments: Documents/routing slip.doc 2 -28-02 REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: DATE: Planning Division DUE DATE: 054 8-06 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required ❑ DATE: DUE DATE: 06 -15 -06 Approved Approved with Conditions Not Approved (attach comments)❑ Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D06 -132 PROJECT NAME: ALSIDE SITE ADDRESS: 6701 S GLACIER ST Original Plan Submittal X Response to Correction Letter # 1 DATE: 05 -10 -06 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: �� . , �?� 19(1 BLl Division Public Works Comments: Approved ❑ Notation: Documents/routing slip.doc 2 -28-02 ,., PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP APPROVALS OR CORRECTIONS: REVIEWER'S INITIALS: Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUT NG: Please Route Structural Review Required REVIEWER'S INITIALS: Approved with Conditions ❑ Permit Coordinator ❑ Planning Division DUE DATE: 05-11-06 No further Review Required DATE: DUE DATE: 06-0$-06 Not Approved (attach comments) ❑ DATE: Not Applicable ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DEP RTMENTS: ¢A 4'' Bu ding Division Public Works ❑ Complete Comments: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28-02 we PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D06 -132 PROJECT NAME: ALSIDE SITE ADDRESS: 6701 S GLACIER ST DATE: 04 -13 -06 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUJING: Please Route Structural Review Required REVIEWER'S INITIALS: Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg'A, Fire ❑ Ping ❑ PW ❑ Staff Initials: ✓" 611 AWu `f Fire Prevention Structural Incomplete ❑ Planning Division ❑ Permit Coordinator ❑ DUE DATE: 04 -18-06 Not Applicable ❑ No further Review Required DATE: E DUE DATE: 05 -16 -06 Revision No. 1 Date I Received I Staff Initials i Staff i I Date Initials I Issued - I . Staff Initials Summary of Revision: eQ li - cam Received By: I Summary of Revision: re v ic e ( um Received By: Received By: Revision No. I Date Received I Staff Initials I Date Stair - Issued j Initials I Staff Initials Summary of Revision: I _. 1 1 1 Received By: Revision I No. Date Received ( Staff Initials I Date Issued I Staff Initials Summary of Revision: I _. 1 1 1 Summary of Revision: Summary of Revision: Received By: Revision Date No. Received Start Initials I Date Issued I Staff Initials 1 1 Summary of Revision: 1 Received By: Revision No. I Date Received I Staff Initials Date Issued I Staff Initials 1 Summary of Revision: Received By: PROJECT NAME: }\J4IIPE' PERM'` Site Address: @TA &LAC! -- Originh Date: REVISION LOG (pl print) (please print) (please print) please print pl ease pn • Date: 5/11/O 6 Summary of Revision: Created: 8-13 -2004 Revised; 60 /E13 39Vd City of Tukwila Department of Community Development 6300 Southceuter Boulevard, Suite 1100 Tukwila, Washington 48188 ?bone: 206-431-3670 Fax: 206431 -3665 Web site: /gtn: //www.ocrultwilawa.us Revision submittals must be submitted in person at the Permit Center. Revisions wilt not be accepted through the mail, fax, eta • Plan Check/PermitNumber: ❑ Response to Incomplete Letter 11 ❑ Response to Correction Letter # Revision # t = ermit is issued �J Revision requested by a City Building Inspector or Plans Examiner Project Name: [11.5 SUPPLY CEniTee. Project Address: C70( S. s Gl.aciE , R ST• Contact Person: M , ry s re ' e a Pkone Number: 4 33c asa - xz i 1FV 1trp afCc PLAN / C A7TAc PER Ti-W R EOiUFST (3F Ne LC.FN Skeet Number(s): "Cloud" or highlight all areas envision including date envision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on t"'I (a lapphcauonslfomcr•apphconons aolM Arevoion rubmmal , 312IS1V Steven M Mullet. Mayor Steve Lancaster, Director PO' - 13Z . MAY 1 7 2006 PERM"' CENTER LT9i5L590ZI ZZ:5T 900Z/50/50 Date: 5/1006 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206431 -3665 Web site: httn: //www.citukwila.waus Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mall, fan" eta ❑ Response to Incomplete Letter # • Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: ALstoe Project Address: 6701 5. G ac ( e2 ST • Contact Person: Mic.*nv=.- 0'159-tent Phone Number: Summary of Revision: 1 RIFF - -n, -ti+r ArTTRC- 1F0 now MCA; TS RQno.F«i TiiE fl)D trt•PWtS tN ■tmtQ IF ITT 12- i7Arf0 yfraitrr Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: CAAMOndt 117 (ta Entered in Permits Plus on I f ID /000 lapplicauomltonns- applications on line4evuion submittal Created: 8-13 -2004 Revised: Plan Check/Permit Number: D O (V - 132_ Steven M Mullet, Mayor Steve Lancaster, Director INICENE0 err Of TUKWU.A MAY 1 0 2006 PERMIT CENTER License Information License NEWWECI110CP Licensee Name NEW WEST CONSTRUCTION INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601127226 Verify Workers Comp Premium Status Ind. Ins. Account Id Business Type CORPORATION Address 1 5837 221ST PL SE Address 2 City ISSAQUAH County KING State WA Zip 98027 Phone 4255570712 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 2/17/1989 Expiration Date 9/21 /2006 Suspend Date Separation Date Parent Company Previous License Next License Associated License Look Up a Contractor, Electri ^'an or Plumber License Detail Home 4 Safety !; Claims 6: Insurance Workplace Rights Trades & Licensing 1 Find a Law or Rule ! Get a Form or Publication Look Up a Contractor, Electrician or Plumber PrintrLErifndly Version Topic Index I Contact Info Page 1 of 3 General/Specialty Contractor +A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment Iof account and carry general liability insurance. https: // fortress .wa.gov /lni/bbip/Detail.aspx ?License =NEW WECI110CP 05/18/2006 x x x x x x