Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG08-008 - SEATTLE CHOCOLATES
SEATTLE C 1180 AND OCOLATES VER PK W PGO8-008 Parcel No.: 3523049085 Address: Suite No: Cityif Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PLUMBING /GAS PIPING PERMIT 1180 ANDOVER PK W TUKW Permit Number: Issue Date: Permit Expires On: PG08 -008 12/01/2008 05/30/2009 Tenant: Name: Address: SEATTLE CHOCOLATES 1180 ANDOVER PK W , TUKWILA WA Owner: Name: DANELLIE LLC Address: 4664 95TH AVE NE , YARROW POINT WA Contact Person: Name: AMY BECKNER Address: 1180 ANDOVER PK W , TUKWILA WA Contractor: Name: BARKER PLUMBING & CONSTRUCTION Address: 15914 SE 166 PL , RENTON WA Contractor License No: BARKEPC001L2 Phone: Phone: 425 - 264 -2714 Phone: Expiration Date: 06/30/2009 DESCRIPTION OF WORK: RENEWAL OF PERMIT NO: PG07 -048. INSTALL EXISTING DISHWASHER, (1) 3- COMPARTMENT SINK, (2) FLOOR DRAINS, (2) LAV SINKS, (2) 4- STATION GANG HANDWASH BASINS, (6) FLOOR SINKS. EXTEND GAS LINE TO NEW 100 -GAL WATER HEATER. INCLUDES ADDING SEWAGE/EFFLUENT PUMP INCLUDES ADDING CERTIFIED BACKFLOW DEVICE ON CHILLED WATER SYSTEM Value of Plumbing /Gas Piping: Fees Collected: $6,500.00 $388.00 Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 FIXTURE TYPE AND QUANTITY Plumbing (cont.) 0 Building sewer and each trailer park sewer 0 0 Rain water system - per drain (inside bldg) 0 1 Water heater and/or vent 0 0 Industrial waste treatment interceptor, including 1 its trap and vent, except for kitchen type 0 grease interceptors 1 0 Repair or alteration of water piping and/or water 2 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 2 Medical gas piping system serving (1 -5) 2 inlets /outlets for a specific gas 0 2 Medical gas piping (6 +) inlets /outlets 0 4 Gas Piping 1 Gas piping outlets (0 -5) 1 2 Gas piping outlets (6 +) 0 * *continued on next page ** doc: UPC -10/06 PG08 -008 Printed: 12 -01 -2008 City ofTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: PG08 -008 Issue Date: 12/01/2008 Permit Expires On: 05/30/2009 Permit Center Authorized Signature: Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the p - orman - . f work. I am authorized to sign and obtain this plumbing /gas piping permit. l / p� Signature: Al - 411101/ Date: ` ! CO Print Name: 2_ g/6 ba This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -10/06 PG08 -008 Printed: 12 -01 -2008 Parcel No.: 352304908S Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 1180 ANDOVER PK W TUKW SEATTLE CHOCOLATES PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: PG08 -008 ISSUED 01/08/2008 12/01/2008 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. * *continued on next page ** doc: Cond -10/06 PG08 -008 Printed: 12 -01 -2008 i City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: 1--c91-'t 3 / 6 Date: la I' I 0 g doc: Cond -10/06 PG08 -008 Printed: 12 -01 -2008 CITY OF TUKWIL, Community Developme Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.citukwila.wa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Site Address: i r t ) , 4 , h - , - - Pa-iA- bile S Tenant Name: j £4 g74C Voce 7L Property Owners Name: Jam C. King Co Assessor's Tax No.o Mailing Address: 1-/‘ ro y 7554 kr, /Lt£ Name: Suite Number: Floor: New Tenant: Yes Ei ..No C24MP8E f C_ Mailing Address: 4e 05C / / 2' /X il &Je SSE E -Mail Address: /(,/ / C' I � 5"ee Cite CO. Co /1? Company Name: Mailing Address: Contact Person: E -Mail Address: 1 Z5/0 13014 Li. ,U£ 0o-n ��e3 wow, og Pam Sow Yet -re-4J ,4 City Day Telephone: eat. awe City Fax Number: State 98oe y Zip 4e5- 753 -4 `I 6 tJ A ?eve State Zip 2, rMMn a( Contractor Registration Number: 4JIRIMAi V2 2.516 / City Day Telephone: Fax Number: Expiration Date: /69 9go3y State Zip yzs 92/ d 7q7 4z5 r-zo /9 31, 6,-- 2y -zoo 7 Company Name: Mailing Address: Contact Person: E -Mail Address: !'s . Company Name: Mailing Address: Contact Person: E -Mail Address: City Day Telephone: Fax Number: State Zip Q:Wpplications\Forms- Applications On LineU -2006 - Permit Application.doc Revised: 9 -2006 bh City Day Telephone: Fax Number: State Zip Page 1 of 6 Valuation of Project (contractor's bid pry j: $ Scope of Work (please provide detailed information): Existing ..lding Valuation: $ Will there be new rack storage? ❑.... Yes .. No If yes, a separate permit and plan submittal will be required. PLANNING DIVISION: Single family building footprint . ea of the foundation of all structures, plus any decks over 1 ' ches and overhangs greater than 18 inches) *For an Accessory dwelling, ovide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide docum tation that shows that the principal owner lives in one of the dwellings as hi ' r her primary residence. Number of Parking S Is Provided: Standard: Compact: Handicap: Will there be a ch e in use? ❑ Yes ❑ No If "yes ", explain: FIRE PRO TION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 -1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:\Applications\Fonns- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Page 2 of 6 PLI,MBING AND GAS PIPING CONTRACTOR INFORMATION 3"-/ - - /944.74:-11,1 Mailing Address: 70 ; Bc, S' Q 2 Rio v i 0 Company Name: Contact Person: E -Mail Address: n 01`%) f Contractor Registration Number: , IV k 'P C O3 ) L 2 Perni,l .fit o 7- ©V 8 City Day Telephone: Fax Number: C4) n, 9g-0S State Zip /125- G e7 -7511:4 /125-2Z6- 26 E-7 Expiration Datefr 30-07 Valuation of Plumbing work (contractor's bid price): $ Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): 4 1KP PC n.cf 196 (71- Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type; Qty , Future Type ;; Qty Fiixi►re Type Qty . .Fixture Type :; Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain 2 Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic / Floor drain / Sinks 2- Dental unit, cuspidor Shower, single head trap Urinals 4- Dishwasher, domestic, with independent drain / Lavatory iv Water Closet Building sewer or trailer park sewer Rain water system - per drain (inside building) Water heater and /or vent Additional medical gas inlets /outlets - six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors / Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets /outlets for specific gas Q:Wpplications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Page 5 of 6 — Applial; a to`ialli ' ermits�i "" '" `�icatio r " `.� nthis �catio'io �'" Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER Signature: ZED AGENT: Print Name: Mailing Address: Date: /IVO Cr Day Telephone:? 5 , 7 S3 - 0E City w/ L/��A �'�/ Date Application Accepted: �l � � � Date Application Expires: 01-1171 in Staff Initials: nom.^ / /vVv Q:\Applications\Forms- Applications On Line13 -2006 - Permit Applieation.doc Revised: 9 -2006 bh Page 6 of 6 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http:/lwww.ci.tukwila.wa.us Parcel No.: 3523049085 Address: 1180 ANDOVER PK W TUKW Suite No: Applicant: SEATTLE CHOCOLATES RECEIPT Permit Number: PG08 -008 Status: PENDING Applied Date: 01/08/2008 Issue Date: Receipt No.: R08 -00054 Payment Amount: $123.00 Initials: JEM Payment Date: 01/08/2008 10:42 AM User ID: 1165 Balance: $41.00 Payee: SEATTLE CHOCOLATE COMPANY TRANSACTION LIST: Type Method Description Amount Payment Check 15546 123.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts GAS - NONRES PLUMBING - NONRES 000.322.103.00.0 46.00 000.322.103.00.0 77.00 Total: $123.00 6969 01/08 9710 TOTAL 123.00 doc: Receiot -06 Printed: 01 -08 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http.• / /www.ci.tukwila.wa.us Parcel No.: 3523049085 Address: 1180 ANDOVER PK W TUKW Suite No: Applicant: SEATTLE CHOCOLATES RECEIPT Permit Number: PG08 -008 Status: APPROVED Applied Date: 01/08/2008 Issue Date: Receipt No.: R08 -03847 Initials: WER User ID: 1655 Payment Amount: $101.00 Payment Date: 12/01/2008 02:17 PM Balance: $0.00 Payee: SEATTLE CHOCOLATES TRANSACTION LIST: Type Method Descriptio Amount Payment Check 17053 101.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLUMBING - NONRES 000.322.103.00.0 101.00 Total: $101.00 0046 12/01 9707 TOTAL 101°00 doc: Receiot -06 Printed: 12 -01 -2008 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit PERMIT NO. (206)431 -3670 Pro e h e. A i Type of Inspection: F I 1 fJuac Address: ' 7/ J liAkilkViig vv Date Called: Special Instructions: h � - 1-a,15 10<a Date ` � t1�� � O O Requester: : Q Phone N //o� 3B 2vV— 1 — 3 z) 5 Approved per applicable codes. Corrections required prior to approval. COMMENTS: GI (RG1 h- ,, co,'crtic . �w ca e,-,r... 1 z- C -r. l p ,, ?607- o - CJA. S. ,A vvc.. u^vla..ikJ _ Nat '.C)0 fi 14 (..11- U--) AT. Z N CSC T.� s-1 k- d� /el.ee rs e , f % "---A-. �oc'w.t -- Narmi, 1gAe Icit.11A \ ?VIA...A PPr- AytroJe� ? Ltr� (� Ac=. . - 1 A-7-‘,(Q•INL. „Er r , / ,.. \ Date: Iz, /vS Jae .00 REINSPECTION FEE REQUIRE . Prior to inspection, fee must be d at 6300 Southcenter Bl ., Suite 100. Call to schedule reinspection. Receipt No.: (Date: November 5, 2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Attention: Dave Larson, Senior Plans Examiner Regarding: Seattle Chocolates — Building Division Review Memo Permit #: PG08 -008 Dear Dave, Please find attached our responses to the review comments. Comment (1) The two interior grease traps and the 3 -comp sink are shown without venting on the waste and vent riser diagram. Please provide manufacturers listing and install specs for the grease traps and revise this plan as necessary or verify that venting is not required. Response: Added vents to plan and riser, see Sheet P1.0. Comment (2) At 2 fixtures units per gallon of flow from the ejector pump times 22 gallons per minute equals 44 fixture units. See Section 703.2 UPC. Per Table 7 -5 UPC a maximum of 35 fixture units is allowed into a 3 inch horizontal drainage pipe. Response: Added DFU count to riser, total DFU = 25, Revised the 3" gravity grease waste line to forced main note to label piping, see Sheet P1.0. On behalf of HARGIS ENGINEERS, Scott Mechanical DS /nb R: \08 \08165 \Seattle Chocolates Plan Review Response 110508.doc H A R G I S 600 Stewart Street Suite 1000 Seattle, WA 98101 t 206.448.3376 f 1206.448.4450 w 1 hargia.biz ENGINEERS • • Tukwila Building Division Dave Larson, Senior Plan Examiner Building Division Review Memo Date: October 30, 2008 Project Name: Seattle Chocolates Permit #: PG08 -008 Plan Review: Dave Larson, Senior Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. The two interior grease traps and the 3 -comp sink are shown without venting on the waste and vent riser diagram. Please provide manufacturers listing and install specs for the grease traps and revise this plan as necessary or verify that venting is not required. 2. At 2 fixture units per gallon of flow from the ejector pump times 22 gallons per minute equals 44 fixture units. See section 703.2 UPC. Per Table 7 -5 UPC a maximum of 35 fixture units is allowed into a 3 inch horizontal drainage pipe. Should there be questions conceming the above requirements, contact the Building Division at 206- 431 -3670. No further comments at this time. • Page 1 July 7, 2008 • City of Tukwila • Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Amy Beckner Seattle Chocolates 1180 Andover Pk W Tukwila WA 98188 RE: Request for Extension Development Permit No. D07 -174 Electrical Permit No. EL08 -073 Plumbing /Gas Piping Application No. PG08 -008 Seattle Chocolates —1180 Andover Pk W Dear Ms. Beckner, This letter is in response to your written request for an extension to Permit Nos. D07 -174 and EL08 -073 and Application No. PG08 -008. The Building Official has reviewed your letter and considered your request to extend the above referenced permits and application. The City of Tukwila Building Division will be extending the expiration date through July 31, 2008 only. Any further extensions will be discussed and decided upon at the proposed meeting the week of July 21st. If you should have any questions, please contact our office at (206) 431 -3670. Sincerely, V\A fer Marshall it Technician P:\Permit Center\Extension Letters\Permits\2007\D07 -174 Pemrit Extension.doc Page 1 of 1 jem 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206 - 431 -3665 July 3, 2008 Bob Benedicto, Building Official City of Tukwila Department of Community Development 6300 Southcenter Blvd., Ste 100 Tukwila, WA 98188 ILIF-t7 -oco RE: nRCEIVED ...cry OF Itilat JUL 03 2008 PERMIT CEa\iru, 7 Permit #s D07-174, EL08-073 and Application # PG08-008 Request for Extension accvytc: o t Mr. Benedicto, lr"st- /1 tuvci ( 1:4)14 l'evt 0.40 1-4,7 t-r:a, 1?-4:2;10k I am writing to request an extension of time on the above-referenced permits and application. PG08-008 (exp. 7/6/08): we are working with a new plumbing contractor to resolve the issues raised in Correction Letter #1, and plan to have the required documentation submitted by the end of July. D07-174 (exp. 7/15/08): active, pending a meeting with your office and our arphiteGt-regarding the issues raised in Correction Letter #1 to Revision #1. We hope to schedule this meeting "--) with your office for the week of July 21€4. MtL 44c: 4 EL08-073 (exp. 7/16/08): the bulk of the work covered by this permit is complete, and our electrical contractor is currently working to resolve any potential issues that may remain. We plan to request the final inspection on this permit by the end of July. We are working actively with your department as well as our contractors to resolve these issues in as timely a manner as possible. However, they will not be resolved prior to the above-stated expiration dates. Thank you in advance for your time and assistance in this matter. If you have any questions, please feel free to contact me. Amy Beckner Office Manager r7g.\--t-E,Np -ZA/ 4)1t.i. '11:717ct47 i)t4vIti:r1HCt (1-.)r.rtvo Seattle Chocolate Company 1180 Andover Park West • Seattle, Washington 98188 • (425) 264-2800 • Fax: (425) 264-2811 • Toll Free: (800) 334-3600 www.seattlechocolates.com 6�� 06 -05 -2008 AMY BECKNER 1180 ANDOVER PK W TUKWILA WA 98188 • City qf Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director RE: Permit Application No. PG08 -008 1180 ANDOVER PK W TUKW Dear Permit Applicant: In reviewing our current permit application files, it appears that your permit application applied for on 01/08/2008 , has not been issued by the City of Tukwila Permit Center. Per the Uniform Plumbing Code and/or International Fuel Gas Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and void. Your permit application expires on 07/06/2008 . If you choose to pursue your project, a written request for extension of your application addressed to the Building Official, demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 07/06/2008. If it is determined that an extension is granted, your application will be extended one time only, for an additional 180 days from the expiration date. In the event we do not receive your written request for extension, your permit application will become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, fer Marshall t Technician xc: Permit File No. PG08 -008 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206- 431 -3665 • City of Tukwila Jim Haggerton, Mayor January 15, 2008 Department of Community Development Jack Pace, Director Niel Campbell 6601 — 128th Avenue SE Bellevue, WA 98006 RE: CORRECTION LETTER #1 Plumbing /Gas Piping Application Number PG08 -008 Seattle Chocolates —1180 Andover Pk W Dear Mr. Campbell, This letter is to inform you of corrections that must be addressed before your plumbing permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Public Works Department has no comments. Building Department: Allen Johannessen, at 206 433 -7163 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sipcerely, Brenda Holt Permit Coordinator encl xc: File No. PG08 -008 P:\Permit Center \Correction Letters\2008\PG08 -008 Correction Ltr # 1.DOC wer 6300 Southcenter Boulevard-, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Tukwila Building Division Allen Johan�nessen, Plan Examiner Building Division Review Memo Date: January 14, 2008 Project Name: Seattle Chocolates Permit #: D08 -008 Plan Review: Allen Johannessen, Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Plumbing plans provided, including the description for new scope of work noted on the permit application, do not accurately illustrate all plumbing work for this permit or the expired plumbing permit (PG07 -048). Provide new plans that clearly illustrate or identifies all plumbing that has been completed. Provide a plumbing as -built plan prior to new plumbing work. Plans shall show sufficient clarity to identify all new plumbing systems since the beginning of this buildings upgrading for Seattle Chocolates: (IBC 106.1:1) 2. In addition to item #1 identify where the sewage ejector pump shall be installed with sufficient details. (IBC 106.1.1) NOTE: Below is the scope of work shown for the previous expired permit. PG07 -048 (expired permit) INSTALL EXISTING DISHWASHER, (1) 3- COMPARTMENT SINK, (2) FLOOR DRAINS, (2) LAV SINKS, (2) 4- STATION GANG HANDWASH BASINS, (6) FLOOR SINKS. EXTEND GAS LINE TO NEW 100 -GAL WATER HEATER. REVISION NO. 1 INCLUDES ADDING SEWAGE/EFFLUENT PUMP REVISION NO. 2 INCLUDES ADDING CERTIFIED BACKFLOW DEVICE ON CHILLED WATER SYSTEM Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. • PERMIT COORD COPY � PLAN REVIEW /ROUSING SLIP ACTIVITY NUMBER: PG08 -008 PROJECT NAME: SEATTLE CHOCOLATE CO DATE: 11 -06 -08 SITE ADDRESS: 1180 ANDOVER PK W Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 2 Revision # After Permit Issued DEPARTMENTS: �I Building Division n Public Works Fire Prevention Structural Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete ❑ DUE DATE: 11-11-08 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS R TING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved U Notation: REVIEWER'S INITIALS: Approved with Conditions DUE DATE: 12-09-08 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 oP ERINIT COORD COPY s PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG08 -008 DATE: 10 -22 -08 PROJECT NAME: SEATTLE CHOCOLATES SITE ADDRESS: 1180 ANDOVER PK W Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Lion Building !vision Public Works 1 1 n Fire Prevention Structural a Planning Division ❑ Permit Coordinator 1g1 DETERMINATION O COMPLETENESS: (Tues., Thurs.) DUE DATE: 0-23-08 Complete Comments: Incomplete n Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ LETTER OF COMPLETENESS MAILED: Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: nNo further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11-20-08 Approved 1 1 Approved with Conditions n Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only i CORRECTION LETTER MAILED: 0 " 3 0' 0 8 Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: ""Y\ Documents/routing slip.doc 2 -28-02 • PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG08 -008 PROJECT NAME: SEATTLE CHOCOLATES SITE ADDRESS: 1180 ANDOVER PK W DATE: 01 -08 -08 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEP RTMENTS: Bu I Diviisi6n' Public Works Fire Prevention Structural Planning Division nPermit Coordinator n n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete WI Incomplete Comments: DUE DATE: 01-10-08 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: n APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions r 1 Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DUE DATE: 02-07-08 DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 • • City of Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 1 -(o_pg Plan Checic/Permit Number: ta+t- 046 -001, ❑ Response to Incomplete Letter # Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: ��•ccy� c�.l ear �o Project Address: ) Mac, ese pp 1g %?. vc.- e...l -1 1L%'-, vj 4 Contact Person: 5v_, — Phone Number: 2 4115 (4,1 Summary of Revision: sae A -Tnpg.p P H.s c1n►.;�- NOV 0 �r LA TER Sheet Number(s): "Cloud" or highlight all areas of revision including date of re ision Received at the City of Tukwila Permit Center by- Entered in Permits Plus on applications\forms- applications on Iine\revision submittal Created: 8 -13 -2004 • • City of Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: (0 - 22- o n Plan Check/Permit Number: P -A _ -00 oN) ❑ Response to Incomplete Letter # D-----Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: �� �=�—m _-t- c° 1—I (-3 cn Project Address: 1143ca A-A.1 vir Contact Person: bcus--G c T Phone Number: '2c�e, ¢ 3 tp e 4-7--f Summary of Revision: C a-t.i �r 1 RECEIVED V OF TUKWILA OCT 2 2 2000 Sheet Number(s): "Cloud" or highlight all areas of revision including date of revisio Received at the City of Tukwila Permit Center by: 12-- Entered in Permits Plus on 10 ' \applications\forms- applications on line\revision submittal Created: 8 -13 -2004 Untitled Page • • General /Specialty Contractor A business registered as a construction contractor with Lai to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip BARKER PLUMBING ft CONSTRUCTION 4252262687 604 SHELTON AVE NE RENTON WA 98056 County KING Business Type INDIVIDUAL Parent Company UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 602032138 ACTIVE BARKEPC001L2 CONSTRUCTION CONTRACTOR 6/22/2000 6/30/2009 BARKEPC062B4 GENERAL UNUSED Business Owner Information Name Role Effective Date Expiration Date BARKER, RANDY L OWNER 01/01/1980 Bond Amount WINSLOW, BOBBI OWNER 06/25/2002 11/13/2002 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 HARTFORD FIRE INS CO 52BSBCE0351 04/04/2003 Until Cancelled $12,000.00 04/24 /2003 2 HARTFORD FIRE INS CO 01BSBAR6132 04/04/200104/04 /2003 $4,000.00 04/16/2001 1 OLD REPUBLIC SURETY CO WW6109662404/04/2000Untd Cancelled 04/01 /2001 $4,000.00 Insurance Information Page 1 of 2 Insurance Company Name policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 8 OHIO CAS INS CO BH00853376639 06/20/2006 06/20 /2009 $1,000,000.00 05 /21/2008 7 OHIO CAS INS 53376639 06/20/2005 06/20 /2006 $1,000,000.00 06 /30/2005 https: // fortress .wa.gov /lni/bbip/Detail.aspx ?License= BARKEPC001 L2 12/01/2008 KEYED NOTES: 0 0 • NOT • PROVIDE LABEL " • R ED M ' PUMPED G BOVE FLOOR) PROVIDE LABEL "FORCED MAIN ". • NOT USED • 1-1/2" VENT PIPE UP. • NOT USED L`1 2" VENT PIPE DN. $ 2" WASTE PIPE UP. • 2" VENT PIPE UP. 01 2" WASTE PIPE DN. 11 NOT USED 12 NOT USED 13 NOT USED 14 3" WASTE PIPE 15 3" WASTE PIPE UP. 16 NOT USED 17 3" VENT PIPE UP. 18 TRAP PRIMER AND 3/8" PRIMER LINE TO FLOOR DRAIN DN. IG. A OVE FLOOR) 3" GRAVITY WASTE (40) VERTICAL DFU DFU EA. 2" STAND PIPE 3 DFU CO 8 DFU 19 DFU FLOW CONTROL 22 DFU TOTAL CLEANING TATI 2 DFU 2FU 3 —COMP 2 DFU LAV 2 DFU CI DUPLEX PUMP SYSTEM "ZOELLER WASTE —MATE 22 GAL. CYCLE. 20 GPM AT 18' OF HEAD" 20 EXIST. SUMP PUMP TO REMAIN. 21 WASHING MACHINE DRAIN BOX 2" STAND PIPE 2 60# GREASE TRAP USED AS A CHEMICAL TREATMENT BATH TO BREAK DN. CHOCOLATE, PRIOR TO DRAINING TO UNDERGROUND PLUMBING SYSTEM. MSDS #6411, 2— BUTOXYETHANOL PROPRIETARY SURFACTANT BLEND 2 WATER. SUMP PUMP CONTROL PANELS COMPLETE WITH ALARM LIGHT' AND ANNUNCIATOR 1, GENERAL NOTES: 1. ALL WORK SHOWN IS EXISTING. THIS DRAWING DOCUMENTS THE EXISTING GENERAL FIELD ROUTING OF PLUMBING PIPING THAT WAS VISIBLE FOR REVIEW. 2. ALL PLUMBING WORK SHALL CONFORM TO LOCAL AUTHORITY HAVING JURISDICTIONS REQUIREMENTS, INCLUDING THE CITY OF TUKWILA AMENDMENTS PLUMBING LEGEND: FD FS GT GI LS DW CO LAV VTR 1-1/2" 1--1 /2" - ,-- 2 „ 1--1 /2" r � FLOOR DRAIN FLOOR SINK GREASE TRAP GREASE INTERCEPTOR LOUNGE SINK DISH WASHER CLEAN OUT LAVATORY (WASH STATION) VENT THROUGH ROOF ii SUMP W /DUPLEX PUM WITH CHECK AND GATE VA TO EXIST. BLACK WATER PUMP STATION (EXISTING) 1 000 GAL. EXTERIOR GREASE INTERCEPTOR WASTE AND VENT RISER DIAGRAM GREASE SYSTEM' SCALE: NTS —1 /2" 1 —1 /2" '1000 GAL. EXTERIOR GREASE INTERCEPTOR FIRST FLOOR PLUMBING PLAN SCALE: 1/16" = 1' —O" , P1.0 f SCALE: 1 /8" = LOUNGE SINK (TYP. OF 2) FIRST FLOOR PLUMBING PLAN —0 3" VTR 3 SCALE: 1/8" = 1' -0" MEZZANINE FLOOR PLUMBING PLAN FZLEI ropy Permit No Mar review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Fie d Co y __conditions is acknowlctiged: By Date: , l i U Cy oTukwila BUILDING D V SIO REVISIONS' No changes shall be made to tho scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal 1 and may include additional plan review fees. DISH WASHER CONNECTION FS 2 —COMP SERVICE SINK CLEANING STATI N KtV iiVV W r'U K CODE COMPI ANCE APPROVED NOV 2 5 Zane City Of Tu BJ1 P R ..L CORRECTION LTR# : : : : : : ::........ SEPARATE REQUIRE[ i echa lff Electric 0 plumbic 0 Gas Pif City of Tul E3UILDING DI DERM1T ? FOR: lical al ig ing :wile VISION 0 ESC 1< REV. RELEASE PERMIT SET CORRECTIONS PROJECT NO. HARGIS PROJECT NO. DRAWN BY CHECKED BY APPROVED BY SHEET TITLE MEZZANINE PLUMBING FLOOR PLAN SHEET NUMBER RECEIVED CITY OF TUKWILA NOV 0 6 2Q08 PERMIT CENTER DATE 10/22/08 11/06/08 P1.0 08165 06165 DS RC RC LEVEL 1 -