Loading...
HomeMy WebLinkAboutPermit PG08-013 - SABEY CORPORATION - DATA CENTERSABEY 3355 S 120 PL PGO8-O 13 Parcel No.: Address: Suite No: Cityif Tukwila B Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206- 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 1023049069 3355 S 120 PL TUKW PLUMBING /GAS PIPING PERMIT Permit Number: Issue Date: Permit Expires On: PG08 -013 01/25/2008 08/02/2008 Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: SABEY DATA CENTER 3355 S 120 PL , TUKWILA WA SABEY CORPORATION 12201 TUKWILA INTL BLVD 4THFL , SEATTLE WA CHRIS CORY 26307 112 ST E , BUCKLEY WA Contractor: Name: SPT MECHANICAL Address: PO BOX 886 , BOTHELL WA Contractor License No: SPTMEM *938BN Phone: Phone: 206 465 -3266 Phone: 206 - 240 -4730 Expiration Date: 01/26/2009 DESCRIPTION OF WORK: ROUGH IN NEW MEN AND WOMENS RESTROOM REVISION #1 RECEIVED FROM CHRIS CORY TO ADD BREAK ROOM SINK ON OUTSIDE WEST WALL OF RESTRROM AT SOUTHWEST CORNER Value of Plumbing /Gas Piping: Fees Collected: $20,000.00 $280.00 Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent dram Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals - Water Closet Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 FIXTURE TYPE AND QUANTITY Plumbing (cont.) 0 Building sewer and each trailer park sewer 0 0 Rain water system - per drain (inside bldg) 0 0 Water heater and/or vent 0 0 Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 2 grease interceptors 0 0 Repair or alteration of water piping and/or water 3 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 2 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 0 0 Medical gas piping (6 +) inlets /outlets 0 1 Gas Piping 1 Gas piping outlets (0 -5) 0 3 Gas piping outlets (6 +) 0 * *continued on next page ** doc: UPC -10/06 PG08 -013 Printed: 03 -20 -2008 City oltrukwila e Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: PG08 -013 Issue Date: 01/25/2008 Permit Expires On: 08/02/2008 Permit Center Authorized Signature: LAL-nv__,A32, Date: -- - 0 g I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or , - •erformance of work. I am authorized to sign and obtain this plumbing /gas piping permit. Signature: Print Name: ae.-tdd ill I Date: 3ba /S This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -10/06 PG08 -013 Printed: 03 -20 -2008 Parcel No.: 1023049069 Address: Suite No: CitAf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci:tukwila.wa.us 3355 S 120 PL TUKW PLUMBING /GAS PIPING PERMIT Permit Number: Issue Date: Permit Expires On: PG08 -013 01/25/2008 07/23/2008 Tenant: Name: Address: SABEY DATA CENTER 3355 S 120 PL , TUKWILA WA Owner: Name: SABEY CORPORATION Address: 12201 TUKVVILA INTL BLVD 4THFL , SEATTLE WA Contact Person: Name: CHRIS CORY Address: 26307 112 ST E , BUCKLEY WA Contractor: Name: SPT MECHANICAL Address: PO BOX 886 , BOTHELL WA Contractor License No: SPTMEM *938BN Phone: Phone: 206 465 -3266 Phone: 206 - 240 -4730 Expiration Date: 01/26/2009 DESCRIPTION OF WORK: ROUGH IN NEW MEN AND WOMENS RESTROOM Value of Plumbing /Gas Piping: Fees Collected: $20,000.00 $265.00 Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet - - Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 FIXTURE TYPE AND OUANTITY Plumbing (cont.) 0 Building sewer and each trailer park sewer 0 0 Rain water system - per drain (inside bldg) 0 0 Water heater and/or vent 0 0 Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 2 grease interceptors 0 0 Repair or alteration of water piping and/or water 3 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 2 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 0 0 Medical gas piping (6 +) inlets /outlets 0 0 Gas Piping 1 Gas piping outlets (0 -5) 0 3 Gas piping outlets (6 +) 0 * *continued on next page ** doc: UPC -10/06 PG08 -013 Printed: 01 -25 -2008 City ofTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site http: / /www.ci.tukwila.wa.us Permit Number: PG08 -013 Issue Date: 01/25/2008 Permit Expires On: 07/23/2008 Permit Center Authorized Signature: I hereby certify that I have read and e Date: o L f v Io ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied dfit , whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction ormance of work. I authorized to sign and obtain this plumbing /gas piping permit. Signature: -C Date: 1 ? o- Print Name: \ / vevJo . ��l�Iil ✓ T� This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -10/06 PG08 -013 Printed: 01 -25 -2008 Parcel No.: 1023049069 Address: Suite No: Tenant: • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206- 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 3355 S 120 PL TUKW SABEY DATA CENTER PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: PG08 -013 ISSUED 01/09/2008 01/25/2008 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed m compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. * *continued on next page ** doc: Cond -10!06 PGO8 -013 Printed: 01 -25 -2008 • e City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: Date: 10,%:5-- ordinances governing or local laws regulating doc: Cond -10/06 PG08 -013 Printed: 01 -25 -2008 CITY OF TUKWI• Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us 11111 Plumbing/Gas Permit No. 1K.,12- 01 S Project No. (For ofike,:nse only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in otder to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: Site Address: / 1ot±1 PL, s7e3b-e/ Dcc C--e/J4-t Property Owners Name: Si} be, 7 C of Mailing Address: / "Z- 2 0 / /,Jc Tenant Name: Suite Number: 102v)01-1- 10(44 New Tenant: Floor: 13 Yes ENo e.J / JS/ULl , 5c, 4' Seterne City State Zip CONTACT PERSON 2 ho do we contact when your permit isreadytoibelained • , • ,, Name: Mailing AddreSs: Z6 307 //? (2w7 Day Telephone: 206-1--/6_S-- LCZ/ey Civ State Zip E-Mail Address: (2_,40.5 Aeedic.,/wec, 1. Cok-t Fax Number.060 g Company Name: Mailing Address: Contact Person: 5 PT eho/Lii c c, I 1Z'7 2r- Ar 6/L iS e.--c-SP frfecifciAi 1 Cokt,, E-Mail Address: �r c5': $04e4 b./ Contractor Registration Number: C P T-144 6-m 9 3 S---Y A-) City State Day Telephone: a), e--/65--- & ‘„ Fax Number: 3 6.0 - / Expiration Date: 0E 212 101 Company Name: Mailing Address: Contact Person: E-Mail Address: Company Name: Mailing Address: Contact Person: E-Mail Address: City Day Telephone: Fax Number: State Zip OAApplicatio6sTorrns-Applicattons On Linel3-2006 - Plumbing-Gas Piping Permit Applicanon.doe Revised: 4=2006 bh City Day Telephone: Fax Number: State Zip Page 1 of 2 Valuation of Project (contractor's bid price): $ C ) () O C) Scope of Work (please provide detailed information): /2 T /t e<-✓ (Ai() n7 FN S Building Use (per Int'l Building Code): Occupancy (per Intl Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type: Qty Future Type: Qty -: Fixture Type: ;:.Qty . ::F.ixtur-e.Type:: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain 3 Sinks Dental unit, cuspidor Shower, single head trap Urinals i Dishwasher, domestic, with independent drain Lavatory -2 Water Closet S Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets /outlets for specific gas Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN Signature: AUTHOD AGENT: Print Name: d.-/20S LO(/ Mailing Address: Z 36 ? //2 ` 51— C/C1.6=>, wa. 3z/ City Date: 9-- 6 Day Telephone: ZO 6 -L/65 - 3 2-6 6 State Zip Date Application Accepted: 0,100,172, Date Application Expires: 011 opt i ti Staff Initials: bi...., Q:'\Applications\Forms- Applications On Line13 -2006 - Plumbing -Gas Piping Permi Application.doc Revised: 4 -2006 bh Page 2 of 2 Parcel No.: Address: Suite No: Applicant: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 1023049069 3355 S 120 PL TUKW SABEY DATA CENTER RECEIPT Permit Number: Status: Applied Date: Issue Date: PG08 -013 ISSUED 01/09/2008 01/25/2008 Receipt No.: R08 -00855 Initials: WER User ID: 1655 Payee: Payment Amount: $15.00 Payment Date: 03/20/2008 01:40 PM Balance: $0.00 SPECIAL PROJECTS TEAM MECHANICAL TRANSACTION LIST: Type Method Descriptio Amount Payment Check 5062 ACCOUNT ITEM LIST: Description 15.00 Account Code Current Pmts PLAN CHECK - NONRES PLUMBING - NONRES 000/345.830 000.322.103.00.0 3.00 12.00 Total: $15.00 5241 03/20 9710 TOTAL i.. (kw.. Reneint -OR Printed. 03- 20-2Of1R City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 1023049069 Address: 3355 S 120 PL TUI W Suite No: Applicant: SABEY DATA CENTER RECEIPT Permit Number: PG08 -013 Status: PENDING Applied Date: 01/09/2008 Issue Date: Receipt No.: R08 -00079 Initials: JEM User ID: 1165 Payment Amount: $265.00 Payment Date: 01/09/2008 01:08 PM Balance: $0.00 Payee: SPECIAL PROJECTS TEAM MECHANICAL INC TRANSACTION LIST: Type Method Description Amount Payment Check 5058 265.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES PLUMBING - NONRES 000/345.830 53.00 000.322.103.00.0 212.00 Total: $265.00 7033 01/09 9710 TOTAL 265.00 doc: Receiot -06 Printed: 01 -09 -2008 INSPECTION RECORD Retain a copy with permit INSPECT! N NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 -013 Project. SA../3 �I /)A7P c e'n 1 Type of Inspection: C,',u A p I a- - 1 i Address: �/.� 3 3. S S J;--1 "� J) 6 L PI_ Date Called: Special Instructions: / Date Wanted / a.m. 3 J - p.m. Requester: Phone No 7,0 (0 — 30-4 - SO (0 Z Approved per applicable codes. Ei Corrections required prior to approval. COMMENTS: Inspect Date ‹' _3 J -06 $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: !Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 P o8--dd 3 Project: 5/96 (i 2/97-4 _ � Type of Inspection: ' —vim Addres S/Za JJ Date Called: Special Instructions: Wanted/ Date Wanted/:: /// Q a.m: Requester: Ph 6 ne N 2 3vy 6667 ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: ,` A J",14( 1 57-11( vA P 2 A is-) ,, l to P c.,, t .1.;,'TZN. 1J d f .1 6-9 ,).1 0 - I , J", / J 1 rte ?` ��.v6t! Inspectlor: 4 \• . : C171 L 1Dat 4_ 6 ( $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a,copy with permit »4 d/3 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION le 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Pro ec - - 9 / -/A ( 'A/ Type of Inspection: / r' 41/9/1 - 1/1) '/›t n,7 A � Adds pe3ir l 2 P L Date Called: SpeciallInstructions: DateWanteed : a.m. — J ,L W G P.m. Requester: Phone No. /-2 44!) _ - 6C/ - 8 . C 7 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: p / A/4;f -e - 4t/ M-L1,/ re Inspectorijelt,t,� Date -3/ V 2 U El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee. -must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit Kle- 613 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: _SA g-tn prA (e4 .4 Type of Inspection: RoJ 6 4-- -r J pu .s. A C, Address: ( -g. 3317 50111 120 PL Date Called: Special Instructions: Date Wanted: 2 "4 SOS •„a,. ,n.; p.m. Requester: Phone No: ! ( o ' o' — 'O O 2— Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Inspect MIR $58.00 REINSPECTION FE REQUIRED. Prior o inspection, fee must be lvd., Suite 100. Call the schedule reinspection. Date: 2 - f o „, paid at 6300 Southcenter Receipt No.: Date: 4111ERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG08 -013 DATE: 01 -09 -08 PROJECT NAME: SABEY DATA CENTER SITE ADDRESS: 3355 S 120 PL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: BAng 'vision Public Works Fire Prevention n Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete Planning Division Permit Coordinator DUE DATE: 01-15-08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: Structural Review Required No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 02 -17-08 Approved ❑ Approved with Conditions I V I Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 • City of Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 'all, O Plan Check/Permit Number: PG-0F = O 13 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # J Revision # ! after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: _S E Y D.TA- c i-r R / 2 "`e FLook RE5TRooM Project Address: 33 5-5- - 1 aO ' PL U I< 1,,VI LAS Ar. Contact Person: C N Rr _ co Ay Phone Number: 2 0 6- 'f ('S- 3 2 6 6 Summary of Revision: ZNST L.L EAk RaoM Stuk Uh ours DE -' sr L'4LL OF RFSTRoo M SOuDI1WL —ST fORNER. R CENED ,(a / CIF Tt lteWILA AA A D c) C 1(tlla PERMIT Sheet.Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on 3- 10 -0 \applications\forms- applications on linekevision submittal rte,i• a- ttanne Look Up a Contractor, Electra or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. License Information License SPTMEM *938BN Licensee Name SPT MECHANICAL Licensee Type CONSTRUCTION CONTRACTOR UBI 602676285 Ind. Ins. Account Id VICE PRESIDENT Business Type CORPORATION Address 1 PO BOX 886 Address 2 City BOTHELL County KING State WA Zip 98011 Phone 2062404730 Status ACTIVE Specialty 1 PLUMBING Specialty 2 BOILER/STEAM FIT/PROC PIPING Effective Date 1/26/2007 Expiration Date 1/26/2009 Suspend Date Separation Date Parent Company SPECIAL PROJECTS TEAM MECH INC Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date BAGGOTT, TOM GORDON PRESIDENT 01/15/2007 CORY, ROBERT VICE PRESIDENT 01/15/2007 MILLER, KEN VICE PRESIDENT 01/15/2007 • Bond Information Bond Bond I Paged of 2 https: // fortress. wa. gov /lniIbbip /printer.aspx ?License= SPTMEM *938BN 01/25/2008 GENERAL NOTES 1. CONTRACTOR SHALL COMPLY WITH THE CURRENT "GENERAL CONDITIONS," AND BUILDING STANDARDS AS PROVIDED BY THE BUILDING OWNER. 2. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF DIFFERENT TRADES. 3. DO NOT SCALE DRAWINGS. CONTACT ARCHITECT FOR ANY MISSING DIMENSIONS. 4. CONTRACTOR INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE OWNER AND ARCHITECT FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWING ONLY WILL NOT SATISFY THIS REQUIREMENT. 5. ALL MODIFICATIONS, REQUIRING OWNER OR ARCHITECT APPROVAL WILL NOT BE VALID UNLESS AUTHORIZED IN WRITING BY OWNER AND /OR ARCHITECT. 6. WITHIN FIVE (5) BUSINESS DAYS OF START OF CONSTRUCTION, THE CONTRACTOR SHALL NOTIFY IN WRITING BOTH THE ARCHITECT AND OWNER OF ANY ITEMS WHOSE ESTIMATED DELIVERY TO THE SITE WOULD BE LATER THAN THAT REQUIRED FOR TIMELY INSTALLATION IN THE CONSTRUCTION SEQUENCE SUBSTITUTION OF ALTERNATE ITEMS WITH SHORTER LEAD TIMES, PAYMENT OF RUSH FABRICATION OR DELIVERY CHARGES OUT OF SEQUENCE INSTALLATION, OR DELAY OF INSTALLATION OPTIONS TO BE AT THE SOLE APPROVAL OF OWNER OR ARCHITECT. 7. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL WORK AND MATERIALS IN ACCORDANCE WITH THE LATEST LOCAL BUILDING CODES AND ORDINANCES. 8. CONTRACTOR SHALL VERIFY ALL FIELD DIMENSIONS AND CONDITIONS AND SHALL REPORT ANY CONFLICTS OR QUESTIONS FOR RESOLUTION BEFORE PROCEEDING WITH THE WORK. DO NOT SCALE THE DRAWINGS. 9. THE USE OF WORD "PROVIDE" SHALL ALWAYS MEAN, "FURNISH AND INSTALL, CONNECT, OR SECURE" AS REQUIRED. 10. ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURERS WRITTEN INSTRUCTIONS AND TRADE ASSOCIATES ACCEPTED STANDARDS. 11. CONTRACTOR SHALL PROVIDE A WRITTEN CONSTRUCTION SCHEDULE. THIS SCHEDULE SHALL INCLUDE DELIVERY LEAD TIMES OF CONSTRUCTION ITEMS, AND START AND COMPLETION DATES OF EACH PHASE, THE CONTRACTOR SHALL UPDATE AND PROVIDE SUCH SCHEDULE ON A BIWEEKLY BASIS. 12. WORK MUST BE SCHEDULED WITH THE BUILDING MANAGEMENT TO AVOID DISRUPTION TO THE TENANTS. 13. ACCESS TO AND FROM THE PROJECT SITE, SPECIAL CONDITIONS, NOISY WORK, TIMING OF WORK, INTERRUPTION OF MECHANICAL AND ELECTRICAL SERVICES, RELOCATION OF EXISTING EQUIPMENT, CASEWORK, FIXTURES, FITTINGS, ETC., MUST BE COORDINATED WITH THE BUILDING MANAGEMENT. 14. ADEQUATE CLEANUP, PROTECTION AND PLACEMENT OF ANY CEILING TILES AND /OR OTHER DISRUPTION TO THE ADJACENT TENANT IMPROVEMENTS MUST BE REPLACED BEFORE BUSINESS HOURS OF THAT TENANT IN ORDER THAT THE OCCUPANT WILL NOT BE INCONVENIENCED IN THE NORMAL CONTINUATION OF THEIR OFFICE HOURS. 15. EACH SUBCONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO ADJACENT WORK AND SHALL REPAIR SAID DAMAGE AT THEIR OWN EXPENSE. THIS INCLUDES ALL AREAS ON THE PREMISES SUCH AS: COMMON HALLWAYS, FREIGHT ELEVATOR VESTIBULES, ETC. 16. SCHEDULE THE USE OF THE ELEVATOR WITH BUILDING MANAGEMENT. 17. UPON COMPLETION OF ALL CONSTRUCTION, THE CONTRACTOR SHALL SUPPLY THE LANDLORD WITH ONE SET OF "RECORD" AS -BUILT DRAWINGS, 18. ALL MATERIALS TO BE NEW UON. 19. PATCH ALL DISTURBED AND /OR DAMAGED AREAS AS REQUIRED TO ACCOMPLISH NEW WORK AND AS REQUIRED FOR FINISHED APPEARANCE. 20. GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NECESSARY BACKING, BLOCKING, AND FRAMING FOR LIGHT FIXTURES, ELECTRICAL FIXTURES, CASEWORK AND ALL OTHER ITEMS REQUIRING IT. 21, CONTRACTOR TO COORDINATE ALL FIRE ALARM WORK WITH BUILDING OWNER. 22. ALL PAINT AND FINISH MATERIAL COLORS SHALL MATCH ARCHITECT'S CONTROL SAMPLES AND REQUIRE ARCHITECT'S REVIEW PRIOR TO INSTALLATION. SUBMIT TO ARCHITECT THREE (3) COPIES FOR REVIEW. 23. CONTRACTOR SHALL FURNISH SHOP DRAWINGS FOR REVIEW ON CABINETWORK, MILLWORK AND ANY OTHER SPECIAL ITEMS REQUIRING CUSTOM SHOP FABRICATION. SUBMIT TO ARCHITECT THREE (3) COPIES FOR REVIEW, 24. REPETITIVE FEATURES NOT FULLY SHOWN , OR NOTED ON THE DRAWINGS SHALL BE COMPLETELY PROVIDED AS IF DRAWN IN FULL. 25. THROUGHOUT THE DRAWINGS ARE ABBREVIATIONS WHICH ARE IN COMMON USE. THE UST OF ABBREVIATIONS PROVIDED IS NOT INTENDED TO BE A COMPLETE LIST. THE ARCHITECT WILL DEFINE THE INTENT OF ANY IN QUESTION. SYMBOLS ELEVATION REFERENCE SYMBOL U DETAIL ID D SHEET NO. SECTION REFERENCE SYMBOL DETAIL REFERENCE SYMBOL COLUMN AND /OR GRID LINE SYMBOL DIMENSION LINE: 0 O 20' - L ANGLE © AT CENTERLINE INDICATES FINISHED I SURFACES TO ALIGN DRAWING TITLE BAR TITLE o LJl.- I 1127 DOOR SYMBOL a ' s" FLOOR ELEVATION SYMBOLS (1 5 92' -0" +1' -0 NOMINAL FLOOR N � - ELEVATION HEIGHT (ABOVE /BELOW) BUILDING SPACE / ROOM ID OFFICE SPACE NAME DETAIL IDENTIFICATION DRAWING TITLE GRAPHICAL SCALE SPACE NUMBER DOCUMENT SHEET SYMBOL KEYED SHEET NOTES �- GLAZING SYMBOL REVISION NUMBER ARCH / INTERIOR ABBREVIATIONS BUILDING SUMMARY ADJ AFF ALT ALUM APC APPROX ARCH ACT AV BLDG BOT CAB CL CLG CLR COL CONC CONF DEMO DEPT DF DIA DIFF DIM DTL DW DWG EA EL ELEC ELEV EQ EQUIP EXT FA FD FE FEC FFE FIN FLUOR FLR FO FOIC FURR GA GC GL GWB HC HOW HM HR INCL INFO INSUL LAV LF MATL MAX MDF ADJUSTABLE ABOVE. FINISH FLOOR ALTERNATE ALUMINUM ACOUSTICAL PANEL CEILING APPROXIMATE ARCHITECTURAL ACOUSTICAL CEILING TILE AUDIO VISUAL BUILDING BOTTOM CABINET CENTER LINE CEILING CLEAR COLUMN - CONCRETE - CONFERENCE - DEMOLITION - DEPARTMENT - DRINKING FOUNTAIN - DIAMETER - DIFFUSER - DIMENSION - DETAIL - DISHWASHER - DRAWING - EACH - ELEVATOR - ELECTRICAL - ELEVATION - EQUAL -- EQUIPMENT - EXTERIOR - FIRE ALARM - FLOOR DRAIN - FIRE EXTINGUISHER - FIRE EXTINGUISHER CABINET - FINISH FLOOR ELEVATION - FINISH - FLUORESCENT - FLOOR - FACE OF -- FURNISHED BY OWNER, INSTALLED BY CONTRACTOR FTIC - FURNISHED BY TENANT, INSTALLED BY CONTRACTOR - FURRING - GAUGE -- GENERAL CONTRACTOR - GLASS GYPSUM WALLBOARD - HANDICAPPED - HARDWARE - HOLLOW METAL (STEEL FRAME) - HOUR - INCLUDED OR INCLUDING - INFORMATION - INSULATION - ,LAVATORY LINEAR FOOT - MATERIAL - MAXIMUM - MEDIUM DENSITY FIBERBOARD M ECH MEZZ MFR MIN MISC MTD MIL N/A N IC NTS OC OFF OPNG DVHD P PART PERF PERIM PERP PLAM PLYWD QTY (R) RA RCP REC REF REFR REL REV RM RO RTD SCHED SF SHT SIM SPEC SPKLR SPKR SQ STD STL STOR STRL STRUC SYMM TBD TEL TEMP THK TO TOS TYP UON UPS VCT VI F WI WC WD W/O MECHANICAL MEZZANINE MANUFACTURER MINIMUM MISCELLANEOUS MOUNTED METAL NOT APPLICABLE NOT IN CONTRACT NOT TO SCALE ON CENTER OFFICE OPENING OVERHEAD PAINT PARTITION PERFORATED PERIMETER PERPENDICULAR PLASTIC LAMINATE PLYWOOD QUANTITY RELOCATED RETURN AIR REFLECTED CEILING PLAN RECESSED REFERENCE REFRIGERATOR RELOCATE REVISION OR REVISED ROOM ROUGH OPENING RATED SCHEDULE SQUARE FEET /FOOT SHEET SIMILAR SPECIFICATION SPRINKLER SPEAKER SQUARE STANDARD STEEL STORAGE STRUCTURAL STRUCTURAL SYMMETRICAL TO BE DETERMINED TELEPHONE OR TELECOM TEMPERED THICKNESS TOP OF TOP OF SLAB TYPICAL UNLESS OTHERWISE NOTED UNINTERRUPTED POWER SUPPLY VINYL COMPOSITION TILE VERIFY IN FIELD WITH WATER CLOSET WOOD WITHOUT DEFINITIONS AND DIMENSIONS A. DEFINITIONS: 1. "TYPICAL" OR "TYP" INDICATES IDENTICAL COMPLETE SYSTEM FOR THE CONDITION NOTED. 2. "SIMILAR" OR "SIM." INDICATES COMPLETE SYSTEM AND COMPONENTS COMPARABLE TO THE CHARACTERISTICS FOR THE CONDITION NOTED. 3. "AS REQUIRED" INDICATES CONTRACTOR SHALL PROVIDE COMPONENTS REQUIRED TO COMPLETE THE NOTED SYSTEM AS INDICATED IN THE PROJECT DOCUMENTS. 4. "ALIGN" INDICATES ACCURATELY PROVIDE FINISH FACES OF MATERIALS IN STRAIGHT, TRUE, AND PLUMB RELATION ADJACENT MATERIALS. B. DIMENSIONS:. 1. DIMENSIONS ARE INDICATED TO THE FACE OF FINISHED SURFACE AT ALL NEW AND EXISTING CONSTRUCTION, CENTER OF COLUMNS OR GRID LINES UNLESS OTHERWISE NOTED. 2, ALIGNMENT OF PARTITIONS AND FINISHES AS SCHEDULED SHALL BE STRAIGHT, TRUE & PLUMB. DIMENSIONAL LAYOUT SHALL BE IN THE FOLLOWING PRIORITY ORDER, A. STRUCTURAL DRAWINGS B. LARGE SCALE DETAILS C, SMALL SCALE DETAILS D. ENLARGED PLANS AND SECTIONS E. FLOOR PLANS 3. MINIMUM DIMENSIONS FOR ACCESSIBILITY CLEARANCES AND BUILDING CODE REQUIREMENTS SHALL BE MAINTAINED. 4. FLOOR ELEVATIONS ARE INDICATED AT THE FACE OF THE STRUCTURAL SLAB, UNLESS OTHERWISE NOTED. 5. VERTICAL DIMENSIONS ARE INDICATED FROM THE FLOOR ELEVATION TO FACE OF FINISHED MATERIAL, UNLESS NOTED ABOVE FINISH FLOOR - "AFF ". 6. CEILING HEIGHTS ARE INDICATED FROM THE FLOOR ELEVATION TO THE FACE OF SUSPENDED ACOUSTIC CEILING GRID OR FACE OF FINISH MATERIAL FOR OTHER CEILING TYPES, UNLESS OTHERWISE NOTED. 7. DOCUMENTS ARE DRAWN DIAGRAMATICALLY, AND SCALED DIMENSIONS ARE APPROXIMATE. DIMENSIONS SHALL INDICATE REQUIRED SIZE, CLEARANCES, AND RELATIONSHIPS ARE INDICATED BY DIMENSIONS AS NOTED, 1. PROJECT ADDRESS: SABEY DATA CENTER INTERGATE EAST BUILDING 5 -2ND FLOOR 3355 SOUTH 120TH PLACE TUKWILA, WA 98168 2. APPLICABLE CODES & ORDINANCES: A BUILDING CODES INTERNATIONAL BUILDING CODE - 2006 B REGULATIONS & ORDINANCES NFPA C ACCESSIBILITY INTERNATIONAL BUILDING CODE - 2006 ICC /ANSI 117.1 ACCESSIBLE & USABLE BUILDINGS AND FACILITIES 3. GENERAL BUILDING DESCRIPTION: TYPE OF CONSTRUCTION: - ICC CONSTRUCTION TYPE IA FIRE RESISTIVE SYSTEM: SPRINKLERED OCCUPANCY TYPE: B (SERVER FARM) 4. FIRE RESISTIVE CONSTRUCTION REQUIREMENTS: SHAFT ENCLOSURES: 2 HOURS EXIT STAIR ENCLOSURES: 2 HOURS CORRIDORS: 1 HOUR 5, EXITS: APPROXIMATE AREA OF CONSTRUCTION: - 2,251 SQUARE FEET TOTAL APPROXIMATE SUITE AREA. - 185,465 SQUARE FEET OCCUPANT LOAD FACTOR: - 100 NUMBER OF TOTAL PROPOSED OCCUPANTS: - NO CHANGE NUMBER OF EXITS; - NO CHANGE MINIMUM EGRESS WIDTH .REQUIRED: - 3'8 ", 3'0" AT DOORS COMMON PATH OF TRAVEL: - 75' 6. PROJECT DESCRIPTION: CREATE WOMENS AND MEN'S RESTROOM AND JANITOR CLOSET. NEW PARTITIONS, DOORS AND FINISHES, 2004 STREET MAP FILE COPY Permit No. ► - = _ "� Plan review approval is subject to 01101s and omissions. Approval of construction documents does not authorize the violation of any adopted code or odinarllce. Receipt of approved Field Copy and conditions is By Date :, / ���� City of Tukwila BUILDING DIVISION LF .RATE PERMIT E EQUIRED FOR ilMechanicai [Electrical ❑ Plumbing ❑ Gas Piping City of Tukwila LBOILOII1G DIVISION REVISIONS No changes shall be made to the scope of work without prior appoval of . Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees TENANT: Sabey Data Center Intergate East 3355 South 120th Place Seattle, WA 98168 Tel: 206.243.0175 Fax: 206.243.0269 ATTN: JOHN SASSER ARCHITECT: Burgess Design, Inc. 1326 -- 5th Avenue, Suite 500 Seattle, Washington 98101 Tel: 206.587.7120 Fax: 206,587.7122 ATTN: KIP KOLODZIEJSKI EMAIL: kipk @burgessdesign,net BUILDING MANAGER: Sabey Intergate West 12201 Tukwila International Blvd, 4th Floor Seattle, WA 98168 Tel: 206,277.5212 Fax: 206.282.9951 ATTN: SANDRA SUSKIC STRUCTURAL ENGINEER: Engineers NW, Inc. 6869 Woodlawn Avenue, NE Seattle, WA 98115 Tel: 206.525.7560 ATTN: DAN LAKE EMAIL: danl @enwseattle.com GENERAL CONTRACTOR: Sabey Construction. ,' Intergate West 12201 Tukwila International Blvd. Fourth Floor Seattle, WA 98168 Tel: 206.281.8700 Fax: 206.281.9951 ATTN: GLENN PARRY EMAIL: glennp('sabey,com WA License: SABEYC1033KM HVAC CONTRACTOR: TBD ELECTRICAL CONTRACTOR: TBD DRAWING INDEX \ DRAWING ISSUED w 0 PROJECT TEAM r_ 0 N N x X X X x X x X x x GENERAL G.0.0 COVER SHEET / PROJECT INFORMATION G.0.1 PROJECT NOTES G.0.2 SITE PLAN ARCHITECTURAL / INTERIOR A.1.1 DEMOLITION PLAN A.2A.1 CONSTRUCTION PLAN A.2B.1 REFLECTED CEILING PLAN A.2C.1 EQUIPMENT/ ELECTRICAL/ FINISH PLAN A.9.1 DOOR SCHEDULE / DETAILS A.9.2 DETAILS A.9.3 ELEVATIONS/ DETAILS SPECIAL NOTE: STRUCTURAL CALCULATIONS REPORT SUBMITTED TO CITY UNDER SEPARATE COVER IN 8 -1/2" X 11" FORMAT. FLOOR PLATE N.T.S. NO CHANGE TO EXIT. RESTROOMS ARE IN ADDITION TO INITIAL RESTROOM REQUIRED UNDER THE ORIGINAL BUILDING PERMIT. FOR CODE COMP +NCE C�ir APPROVED JAN 1620 Of Tukwila BUILDING Dom:_: ION p! JAN 0 C 0 ;• \:,�lA P�ItC�all CENTER 1 0 P? A Tenant Improvement for: SABEY CORPORATION 12201 Tukwila International Blvd. Suite 400 Seattle, WA 98168 Tenant: SABEY DATA CENTER Intergate East, Building 5 -2ND FLOOR RR & CORR. 3355 South 120th Place Seattle, WA 98168 All reproduction & intellectual property rights reserved c 2006 Professional seal No. Issue Description REVIEW/ PERMIT 12/12/07 Drawn by: RW Reviewed by: KK Project No: 07- 5B07 -00 Date COVER SHEET / PROJECT INFORMATION Original drawing is 24" x 36 ". Scale entities accordingly if reduced G.0.0 PROJECT NOTES DMSION I -- GENERAL CONDITIONS 01010 SUMMARY OF WORK 1. GENERAL DESCRIPTION OF THE PROJECT: NON- STRUCTURAL INTERIOR TENANT IMPROVEMENT OF A COMMERCIAL OFFICE SUITE. 2. WHERE NO BUILDING STANDARDS EXIST FOR MATERIALS CALLED OUT AS "BUILDING STANDARD" ON THE PLANS, THE CONTRACTOR SHALL SO ADVISE BURGESS DESIGN WITHIN TEN (10) DAYS OF THE CONTRACTOR'S RECEIPT OF THE PLANS SO THAT BURGESS DESIGN MAY MAKE ALTERNATE SELECTIONS. 3. CONTRACTOR SHALL VERIFY ALL REQUIREMENTS OF EXACT SIZE AND QUANTITY OF EQUIPMENT FURNISHED BY THE TENANT, INCLUDING REQUIREMENTS FOR MECHANICAL AND ELECTRICAL SERVICES, AND IS RESPONSIBLE FOR ALL ROUGH -IN CONNECTIONS. EACH SUBCONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO ADJACENT WORK AND SHALL REPAIR SAID DAMAGE AT THEIR OWN EXPENSE. 4. FIRE /EMERGENCY SYSTEMS INCLUDE, BUT ARE NOT LIMITED TO, SPRINKLER MODIFICATIONS, FIRE EXTINGUISHER PLACEMENT, AUDIBLE ALARMS, SMOKE AND HEAT DETECTORS, STROBES, AND EXIT SIGN PLACEMENT. 5. MECHANICAL AND ELECTRICAL TO BE DESIGN BUILD UNDER SEPARATE PERMIT. 6. WORK NOT INCLUDED: CONTRACTOR SHALL PROVIDE THE FOLLOWING ITEMS DESCRIBED IN THE SPECIFICATIONS AND SHOWN ON THE PLANS EXCEPT FOR THE ITEMS INDICATED "N.I.C." (NOT IN CONTRACT), SUCH AS TELEPHONE AND DATA CABLES, OFFICE FURNITURE, EQUIPMENT AND MOBILE KITCHEN APPLIANCES. 7. CONTRACTOR TO PROVIDE ALL FIRE /EMERGENCY SYSTEMS AS REQUIRED BY ALL APPLICABLE CODES. FIRE /EMERGENCY SYSTEMS INCLUDE BUT NOT UMITED TO SPRINKLER MODIFICATIONS, FIRE EXTINGUISHERS, AUDIBLE ALARMS, STROBES, SPRINKLERS, SMOKE AND HEAT DETECTORS, AND EXIT SIGNS. 8. EVERY EXIT DOOR SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT, AND SHALL BE EQUIPPED WITH PANIC HARDWARE WHERE REQUIRED AND INDICATED. 9. ANY MATERIAL USED IN CONSTRUCTION SHALL MEET CURRENT FLAME CODE REGULATIONS, 10. ALL ELECTRICAL, PLUMBING AND MECHANICAL MATERIAL INSTALLATIONS SHALL COMPLY WITH THE BUILDING SHELL STANDARD SPECIFICATIONS. DMSION II - SITE WORK 02050 - DEMOLITION 1. FURNISH ALL LABOR, MATERIALS AND EQUIPMENT AS REQUIRED TO COMPLETE THE DEMOLITION AND REMOVAL OF ALL ITEMS LOCATED IN THE CONSTRUCTION AREAS. UPON COMPLETION OF ALL DEMOLITION WORK, ALL AREAS SHALL BE LEFT BROOM CLEAN. 2. DEMOLITION OF TELEPHONES, ELECTRICAL, VOICE /DATA AND PANELS ARE TO BE REMOVED BACK TO ORIGINATING SOURCE. DEMOLITION OF CORES AND RELATED CABELING TO BE REMOVED FROM TENANT SPACES BELOW. 3. DURING THE REMOVAL OF ANY ENVIRONMENTALLY HAZARDOUS MATERIALS, PROTECTION GUIDELINES SHOULD BE STRICTLY FOLLOWED BY CODE OR LOCAL GOVERNING AUTHORITY. 4. ALL EXISTING CONSTRUCTION ITEMS THAT INTERFERE WITH THE CONSTRUCTION NEGOTIATED BY THE PRICING PLAN / SPACE PLAN WITH WORK LETTER SHALL BE REMOVED, RELOCATED, OR KEPT FLUSH IN CEILING, WALL, OR FLOOR AS REQUIRED. 5. ALL DAMAGED AREAS SHALL BE PATCHED AS REQUIRED AND FINISHED TO MATCH EXISTING ADJACENT AREAS OR AS SPECIFIED TO PROVIDE A "LIKE -NEW FINISH ". 6. CONTRACTOR SHALL PROVIDE PLASTIC SHEETING OR OTHER APPROPRIATE BARRIER TO CONTROL DUST AND DEBRIS SUCH THAT IT DOES NOT AFFECT AREAS OUTSIDE THE AREA OF WORK. DMSION VI - ARCHITECTURAL CARPENTRY AND CASEWORK 06100 -- ROUGH CARPENTRY 1. ROUGH CARPENTRY TO INCLUDE ANY WOOD STUDS, FURRING, BLOCKING, ROUGH FRAMING, WOOD CURBS, BUCKS, NAILERS, BACKING, FIXTURE FRAMING, EQUIPMENT SUPPORTS, ETC. AS DETAILED. 06200 - FINISH CARPENTRY 1. FINISH CARPENTRY TO INCLUDE INSTALLATION OF ALL FIXTURES AND ASSOCIATED TRIMS, HARDWARE AND NOSINGS. 2. PROVIDE INTERIOR DOOR AND SIDELIGHT FRAMES AS SCHEDULED. 064Q0 - ARCHITECTURAL WOQPWORK AND CASEWORK 1. CABINET CONSTRUCTION: COMPLY WITH THE A.W.I. ARCHITECTURAL WOODWORK QUALITY STANDARDS FOR CUSTOM GRADE WORK, CABINETS SHALL BE FLUSH CONSTRUCTION. 2. PROVIDE PARTICLE BOARD, MED. DENSITY, WEIGHING <40 LB. /CU. FT., AT LEAST 3/4" THICK. 3. CABINET HARDWARE: FULL EXTENSION DRAWER GU DES, STAINLESS STEEL CABINET PULLS, US32D FINISH, AND CONCEALED DOOR HINGES, SHELF HARDWARE AND OTHER REQUIRED ITEMS, LION IN ELEVATIONS / DETAILS, 4. PLASTIC LAMINATE: HIGH - PRESSURE DECORATIVE LAMINATE SELECTED FROM WILSONART, NEVAMAR, PIONITE, AND FORMICA. LAMINATE TO BE GENERAL - PURPOSE GRADE .050" HORIZONTAL AND .030" VERTICAL. 5. INTERIOR CABINET SURFACES AND SHELVES TO BE OF PREFINISHED BOARD WITH POLYESTER OVERLAY. 6, SHELF EDGING TO BE VINYL. 7. SUBMIT SHOP DRAWING SUBMITTALS FOR ARCHITECT REVIEW. DIVISION VIII - DOORS AND WINDOWS 08210 - WOOD DOORS 1. PROVIDE AND INSTALL INTERIOR SUITE DOORS AS INDICATED ON DRAWINGS. 2. DOOR SCHEDULE SPECIFIES FINISH (BOTH SIDES OF DOOR) AND FRAME, UON, 3. DOORS SHALL BE PRE - MACHINED FOR HARDWARE PER HARDWARE SCHEDULE. 4. SUBMIT SHOP DRAWING SUBMITTALS FOR ARCHITECT REVIEW. 08710 FINISH HARDWARE 1. FINISH AND SPECIALTY HARDWARE INCLUDES ALL ACCESSORIES, TOOLS, AND FASTENERS REQUIRED FOR HARDWARE INSTALLATION AND MAINTENANCE. ITEMS NOT SPECIFICALLY MENTIONED, BUT NECESSARY TO COMPLETE THE WORK, SHALL BE FURNISHED MATCHING IN QUALITY AND FINISH OF SPECIFIED IN SIMILAR LOCATIONS. 2. PROVIDE ALL HARDWARE AS SPECIFIED PER THE HARDWARE SCHEDULE. 3. ALL LOCK SETS SHALL CONFORM TO THE BUILDING'S GRAND MASTER KEYING SYSTEMS. PROVIDE TWO (2) KEYS FOR EACH LOCK AND TWO (2) MASTER KEYS FOR THE SUITE. ALL KEYS TO BE TAGGED WITH ROOM NUMBERS. CONFIRM QUANTITY WITH BUILDING MANAGEMENT. 4. SUBMIT HARDWARE SCHEDULE WITH CATALOGUE CUT SHEETS FOR ARCHITECT REVIEW. 5. ALL DOORS SHALL HAVE A MINIMUM OF 1 -112 PAIR OF BUTT HINGES, ONE LATCHSET OR LOCK SET, AND ONE DOOR STOP TO MEET ACCESSIBIUTY REQUIREMENTS. 6. ALL HARDWARE SHALL BE COMMERCIAL GRADE. 7. PROVIDE CLOSERS PER HARDWARE SCHEDULE AND AT ALL RATED ASSEMBLIES. 08810 - GLASS 1. ALL GLASS AT SIDELIGHTS AND DOORS SHALL BE 1/4" TEMPERED SAFETY GLAZING, UON. 2. THIS PROJECT CONTAINS GLAZING THAT WILL BE SUBJECT TO FEDERAL GLAZING STANDARDS. GLAZING SUBCONTRACTOR SHALL BE RESPONSIBLE FOR ADHERENCE TO THE REQUIREMENTS. IF GLAZING SUBCONTRACTOR FINDS ANYTHING IN THE DOCUMENTS NOT IN COMPLIANCE WITH THE STANDARD, THEY SHALL BRING DISCREPANCIES TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. DMSION IX - FINISHES 0925Q GYPSUM DRYWALL AND METAL STUDS 1. INCLUDE NECESSARY MATERIALS, LABOR AND ACCESSORIES FOR THE INSTALLATION OF ALL PARTITIONS AS SHOWN IN THE PLANS. 2. "WALL SURFACES" MEAN ALL VERTICAL SURFACES INCLUDING COLUMNS WHERE EXPOSED, CONVECTOR OR RADIATOR ENCLOSURES, FASCIAS, RETURNS, PLYWOOD BACKBOARDS, ETC. 3. ALL PARTITION HEADS SHALL MATCH BUILDING STANDARD, UON. 4. WALLS SHOWN AUGNED WITH BASE BUILDING STRUCTURE SHALL BE FLUSH AND SMOOTH WITH BASE BUILDING STRUCTURE, UON. 5. SEISMIC BRACING: PROVIDE SEISMIC BRACING AS REQUIRED PER THE LATEST BUILDING CODES (NEW CONSTRUCTION ONLY) TO THE PARTITION HEADS AND CEIUNG GRID. 6. FRAMING STUDS: GALVANIZED STEEL STUDS PER CONSTRUCTION PLANS. PROVIDE WITH SHEET METAL BACKING WITHIN ALL WALLS RECEIVING CASEWORK (CABINETS, BOOKSHELVES, ETC.). VERIFY STUD SIZE MATCHES DOOR FRAMES IN STOCK IF APPLICABLE. 7. CONTRACTOR SHALL PROVIDE AND LOCATE ACCESS PANELS AS REQUIRED AFTER INSTALLATION OF MECHANICAL DUCTS, PLUMBING, AND ELECTRICAL WORK. FIRE RATE AS REQUIRED. 8. ALL DRYWALL TO BE 5/8" TYPE "X" UNLESS OTHERWISE NOTED. PROVIDE "M /R" TYPE DRYWALL WHERE REQUIRED BY CODE AND AT ALL TOILET ROOMS, AND BEHIND CERAMIC TILES, UON. 9. INSTALL CORNER BEADS AT ALL EXTERNAL CORNERS., INSTALL METAL EDGE TRIM WHENEVER EDGE OF GYPSUM BOARD WOULD OTHERWISE BE EXPOSED OR SEMI - EXPOSED. 10. PRIOR TO RECEIVING FINISH, ALL SURFACES SHALL BE PROPERLY PREPARED AS REQUIRED TO RECEIVE FINAL FINISHING AS SPECIFIED. 11. EXTEND ALL SOFFIT FRAMING TO STRUCTURE ABOVE. PROVIDE DIAGONAL BRACING AS NECESSARY. 12. PROVIDE FRAMING FOR SUSPENDED CEIUNG WITH SEISMIC BRACING IN ACCORDANCE WITH REQUIREMENTS OF APPLICABLE CODES AND AS SHOWN ON DRAWINGS. 13. USE ACOUSTICAL SEALANT AROUND ALL PIPES, DUCTS, CONDUIT, OUTLETS, SWITCHES ETC. ON BOTH SIDES OF CROSSING /PENETRATING WALLS WITH ACOUSTICAL INSULATION. PENETRATIONS OF FIRE -RATED WALLS SHALL BE PROTECTED BY APPLICABLE FIRE -RATED ASSEM BU ES. 09500 - CEILING SUSPENSION SYSTEMS. 1. PROVIDE NEW CEILING TILE, CEILING GRID AND ALL ACCESSORIES AS REQUIRED TO INSTALL SUSPENDED ACOUSTICAL CEILINGS AS INDICATED ON DRAWINGS. 2. PROVIDE SEISMIC BRACING AS REQUIRED BY CODE AT NEW CEILING WORK ONLY. 3. COORDINATE WORK WITH OTHER TRADES HAVING WORK IN THE CEILING AND THE TELEPHONE AND DATA CABLE COMPANIES WHEREVER THEIR RESPECTIVE WORK IS CONTIGUOUS. 4. PROVIDE CUTOUTS AND OTHER SPECIAL PROVISIONS IN ACOUSTICAL WORK AS REQUIRED FOR LIGHTING FIXTURES, REGISTERS, DIFFUSERS, SPRINKLERS, AND OTHER INSERTED ITEMS. 5. ALL CUTOUTS SHALL BE CENTERED WITHIN ACOUSTIC CEILING TILE, UON. 6. ALL MATERIALS SHALL HAVE CLASS 1 FLAME SPREAD RATING AND BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATION AND CODES. 7. ALL JOINTS IN THE TILE FIELD SHALL BE SQUARE, LEVEL AND PERFECTLY ALIGNED WITH EACH OTHER. 8. INSTALLED SUSPENDED CEIUNGS TO BE LEVEL WITHIN A TOLERANCE OF 1/8" IN 12' -0 ". ANCHOR AS REQUIRED. 09530 - ACOUSTICAL TREATMENT 1. PROVIDE ACOUSTICAL INSULATION BETWEEN FRAMING STUDS AND EXTENDING TWO FEET ON EACH SIDE OF PARTITION HEAD ABOVE CEILINGS FOR ALL WALLS NOTED PER PLANS. 2. NEW DEMISING WALL CONSTRUCTION TO HAVE SOUND BATT INSULATION BETWEEN FRAMING STUDS AND TWO FEET OF INSULATION ON EITHER SIDE OF THE PARTITION HEAD ABOVE CEILING GRID. 09650 - RESILIENT FLOORING 1. PROVIDE VCT, SHEET LINOLEUM, SHEET VINYL AND RUBBER BASE AS INDICATED IN DRAWINGS. COLOR AND MANUFACTURER PER FINISH SCHEDULE. 2. PROVIDE RUBBER- REDUCING STRIPS IN COLOR TO MATCH SPECIFIED BASE. REDUCING STRIPS TO OCCUR AT ALL AREAS OF FLOOR MATERIAL TRANSITION. 3. BASE TO BE INSTALLED IN LONGEST AVAILABLE, LENGTH WITH NO PIECE LESS THAN 12 ". NO JOINTS AT OUTSIDE CORNERS OR WITHIN 6" OF CORNERS. 4. PATCH, LEVEL AND PREPARE SUB FLOORING WITH CEMENTITOUS UNDERLAY PER MANUFACTURER'S WRITTEN INSTRUCTIONS IN AREAS TO RECEIVE NEW FLOORING. MAX. ALLOWABLE TOLERANCE = 1/4" OVER 10'. 5. UPON COMPLETION ALL WORK SHALL BE CLEANED AND ALL SPOTS OF ADHESIVE AND SURFACE STAINS REMOVED. 6. GENERAL CONTRACTOR SHALL APPLY FLOOR WAX TO NEW FLOORING AREAS PER MANUFACTURERS SPECIFICATION UON. 09650 - CARPET 1. PROVIDE COMMERCIAL GRADE CARPET AS INDICATED IN DRAWINGS. 2. CARPET TO BE INSTALLED AS INDICATED IN DRAWINGS. 3. PREPARE SUB FLOOR WITH LIGHT WEIGHT CONCRETE UNDERLAY WHERE REQUIRED TO PROVIDE APPROVED SUBSTRATE. MAX. ALLOWABLE TOLERANCE = 1/4" OVER 10'. 4: PROVIDE SEAMING DIAGRAMS FOR ARCHITECT'S REVIEW. 09900 - PAINTING AND STAIN 1. UNLESS OTHERWISE NOTED, PRIME ALL GWB WALL SURFACES AND PAINT WITH MINIMUM OF TWO (2) FINISH COATS OF BENJAMIN MOORE EGGSHELL, FINISH LATEX PAINT OR APPROVED EQUAL. PROVIDE FOR NUMBER OF PAINT COLORS AS • INDICATED IN DRAWINGS. 2. FINISH DOORS, DOOR FRAMES, AND SIDELIGHT FRAMES AS INDICATED IN DRAWINGS. A) PAINTED WOODWORK TO BE FINISHED WITH ONE (1) COAT PRIMER AND TWO (2) FINISH COATS. B) SEALED WOODWORK TO BE STAINED PER FINISH SCHEDULE AND SEALED WITH A COMMERCIAL GRADE CLEAR SATIN VARNISH. 3. PAINT FOR THE LIGHT SURFACES TO CONFORM TO THE REQUIREMENTS OF THE "ARCHITECTURAL SPECIFICATIONS MANUAL" (AWS) FOR PAINT SYSTEMS. LATEX PAINT: AWS SYSTEM 3 -B "CUSTOM" (2 COAT) GRADE LIGHT COLOR PAINT FINISH ON GYPSUM BOARD SURFACES. 4. PAINT FOR THE DARK SURFACES TO CONFORM TO THE REQUIREMENTS FOR THE "ARCHITECTURAL SPECIFICATIONS MANUAL" (AWS) FOR PAINT SYSTEMS. LATEX PAINT: AWS SYSTEM 3 -B "CUSTOM" (2 COAT) GRADE DEEP TONE PAINT FINISH ON GYPSUM BOARD SURFACES. 5. UPON COMPLETION OF WORK, REMOVE EXCESS PAINT, STAIN, VARNISH, ADHESIVE, CAULK, ETC. FROM ALL OTHER SURFACES THAT WERE NOT SPECIFIED TO RECEIVE SAME. 6. TOUCH -UP AND PATCH SURFACES AS REQUIRED AFTER THE COMPLETION OF WORK BY OTHER TRADES. 7. WHERE COLUMNS OCCUR IN AREAS SCHEDULED TO BE FINISHED, THEY SHALL RECEIVE THE SAME FINISH AS THE ROOM UON. DMSION XII - FURNISHINGS 12500 - WINDOW TREATMENT 1. ALL EXISTING INTERIOR AND PERIMETER MINI BLINDS TO BE BAGGED AND CLEANED TO LIKE -NEW CONDITION. 2. ALL PERIMETER GLAZING TO RECEIVE BLINDS AS INDICATED IN DRAWINGS. COORDINATE WITH BUILDING MANAGEMENT. 3. ALL INTERIOR SIDELIGHTS TO RECEIVE 1" MINI - BLINDS WHERE INDICATED IN DRAWINGS. 4. PROVIDE SAMPLE AND CUT SHEET TO ARCHITECT FOR REVIEW. DMSION XV - MECHANIC 15400 - PLUMBING 1. PROVIDE SUPPLY, WASTE AND VENT UN ES, VALVES, FITTINGS, ETC. REQUIRED FOR KITCHEN SINKS, DISHWASHER, REFRIGERATOR, AIR CONDITIONING UNIT(S), VENDING MACHINES, COFFEE MAKER, WATER HEATERS, ETC. 2. ALL FIXTURE INSTALLATIONS SHALL CONFORM TO THE AMERICANS WITH DISABILITIES ACT. 3. PROVIDE NEW PLUMBING FIXTURES AS SPECIFIED PER DRAWINGS. 4. PROVIDE HOT AND COLD WATER TO SINKS /DISHWASHERS. ?* 5. ALL NEW WATER HEATERS ARE TO BE INSTALLED WITH DRIP PAN CONNECTED TO WASTE UNE. 6_ ALL PLUMBING FIXTURES ARE TO BE INSTALLED TO MEET CURRENT GOVERNING LOCAL AND FEDERAL CODES. 7. CONTRACTOR PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 15500 - FIRE PROTECTION 1. FIRE PROTECTION SYSTEM PER BUILDING STANDARD, LOCAL REGULATIONS AND ORDINANCES. 2. PROVIDE ALL EMERGENCY LIGHTING, EXIT SIGNS, FIRE ALARM SPEAKERS, STROBES AND BELLS AS REQUIRED BY CODE. DESIGN AND INSTALL THE SAME IN COMPLIANCE WITH THE AMERICANS WITH DISABILITIES ACT. 3. PROVIDE SPRINKLERS, FIRE RATED DOORS AND FRAMES, FIRE EXTINGUISHERS, ETC. AS REQUIRED BY APPLICABLE LOCAL CODES AND. LAWS. 4. FIRE EXTINGUISHERS SHALL BE BY UNDERWRITER'S LABORATORY 2A -10BC 5 -LB, MULTIPURPOSE EXTINGUISHER WITH SQUEEZE -TYPE HANDLE AND FLEXIBLE DISCHARGE HOSE WITH VISIBLE PRESSURE GAUGE. 5. FIRE EXTINGUISHERS SHALL BE INSTALLED PER BUILDING STANDARD REQUIREMENTS, UON. 6. DESIGN BUILD FIRE PROTECTION DRAWINGS INDICATE: A. LAYOUT, LOCATION, AND SIZE OF SPRINKLER LINES AND HEADS. B. PRESSURE REQUIREMENTS. C. SPRINKLER HEAD SPECIFICATIONS. D. LOCATION OF FIRE PROTECTION RISERS AND WALL HYDRANTS 7. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 8. ALL SPRINKLER HEADS SHALL BE CENTERED IN ACOUSTICAL CEIUNG TILE, UON. 15800 - HEATING VENTILATING AND AIR CONDITIONING 1. PROVIDE BUILDING STANDARD HVAC SYSTEM. WITH ALL MATERIALS, LABOR AND ACCESSORIES FOR COMPLETE OPERATION OF SYSTEM. CONTRACTOR TO BALANCE HVAC SYSTEM AS REQUIRED. 2. DESIGN OF MECHANICAL TO BE PREPARED UNDER A SEPARATE PERMIT. 3, DESIGN BUILD MECHANICAL ENGINEERING DRAWINGS INDICATE: A. DUCTS, AIR MOVEMENT REQUIREMENTS, & SIZES OF GRILLES & REGISTERS. 4. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 5. HVAC CONTRACTOR TO CLEAN, REPAIR OR REPLACE SOILED OR DAMAGED HVAC GRILLS, FILTERS AND THERMOSTATS. 16000 - ELECTRICAL AND TELECOMMUNICATIONS 1. REUSE EXISTING ELECTRICAL AND DATA AS APPROPRIATE TO MEET THE TENANT'S REQUIREMENTS. REPLACE OUTLET COVERPLATES TO MATCH NEW FINISH IF APPLICABLE. 2. PROVIDE ALL WORK, EQUIPMENT AND LABOR FOR A COMPLETE AND OPERABLE ELECTRICAL SYSTEM. PROVIDE ELECTRICAL OUTLETS PER POWER AND DATA PLAN. 3. PROVIDE MUD RING FOR DATA AND COMMUNICATION AS SHOWN ON THE POWER AND DATA PLAN. EACH MUD RING TO HAVE A MINIMUM NUMBER OF WIRE PULLS AS INDICATED ON DRAWINGS. COORDINATE DATA CABLE CONFIGURATION WITH THE TENANT. 4. ALL OUTLETS AND MUDRINGS TO BE LOCATED AT 15" AFF TO THE CENTER LINE, LION. 5. WHERE MULTIPLE DEVISES OCCUR IN A SINGLE LOCATION, ALL DEVICES SHALL BE GANGED UON. 6. ALL ELECTRICAL OUTLETS WITHIN THE CODE REQUIRED DISTANCE FROM A SINK SHALL BE ON A GROUND FAULT INTERRUPTED CIRCUIT. 7. ALL WIRING DEVICES: SHALL BE BUILDING STANDARD EXCEPT: "ISOLATED GROUND" OUTLETS SHALL BE ORANGE, "HOSPITAL GRADE ISOLATED GROUND" OUTLETS SHALL BE ORANGE WITH A GREEN DOT, "EMERGENCY" OUTLETS SHALL BE RED, AND "DEDICATED" OUTLETS FOR "CLEAN CIRCUIT" FIXTURES SHALL BE GRAY (UNLESS BUILDING STANDARD DICTATES OTHERWISE). ALL COVERPLATES SHALL BE BUILDING STANDARD FINISH, UON. 8. PROVIDE SEPARATE CIRCUITS FOR TENANT'S EQUIPMENT (INCLUDING THE TELEPHONE SWITCH, COPIERS, . COMPUTERS, ETC.) WHEN NOTED ON THE CONSTRUCTION DOCUMENTS. 9. COORDINATE SCHEDULE WITH FURNITURE VENDOR FOR THE USE OF ELECTRICIANS DURING THE INSTALLATION OF TENANT'S NEW FURNITURE. 10. ALL ELECTRICAL WIRING, TELEPHONE AND COMPUTER CABLING, AND CONDUIT SHALL BE CONCEALED IN FLOORS, WALLS, OR CEILINGS. CABLING FOR VOICE AND DATA TO BE PROVIDED BY TENANT'S VENDORS AND SHALL BE COORDINATED BY THE BUILDING MANAGER. 11. THE CONTRACTOR IS TO COORDINATE WITH THE OWNER SUPPLIED FURNITURE SYSTEMS TO INCLUDE BUT NOT LIMITED TO: ELECTRICAL AND DATA WIRING LOCATIONS, J- BOX LOCATIONS, CONNECTIONS AND WALL MOUNTED REQUIREMENTS. 12. THE CONTRACTOR IS TO VERIFY EXISTING ABANDONED CORE DRILL LOCATIONS AND FILL AS REQUIRED WITH MATERIAL TO MEET CURRENT FLAME SPREAD REGULATIONS. LOCATIONS TO BE PREPARED TO . RECEIVE NEW FLOOR FINISH AS REQUIRED. 13. ARCHITECTURAL DRAWINGS INDICATE LOCATION ONLY OF DEVICES SHOWN. SWITCHING AND CIRCUITING SHALL BE INDICATED ON SEPARATE ELECTRICAL ENGINEERING AS -BUILT DRAWINGS AND SHALL MEET OWNER'S GUIDELINES. 14. ALL TELEPHONE, ELECTRICAL, COMMUNICATION AND SECURITY WORK SHALL BE COMPLETED IN ACCORDANCE WITH ALL APPUCABLE CODES. 15. DRAWINGS INDICATE ALL DIMENSIONS TO CENTERLINE OF TELEPHONE, ELECTRICAL, AND COMMUNICATION COVERPLATE: OUTLETS SHOWN GROUPED TOGETHER ON PLAN SHALL BE SET TO A MINIMUM DIMENSION BETWEEN EACH DEVICE. 16. BACK -TO -BACK OUTLETS ARE NOT PERMITTED.. OFFSET OUTLETS THE MINIMUM DIMENSION REQUIRED. 17. LOCATION OF ALL WALL MOUNTED POWER AND DATA DEVICES SHALL BE • FIELD REVIEWED BY THE ARCHITECT BEFORE INSTALLATION. 18. ELECTRICAL ENGINEER TO PROVIDE DESIGN /BUILD PACKAGE TO ARCHITECT FOR REVIEW PRIOR TO INSTALLATION. 19. THE LAYOUT DIAGRAMS COORDINATE LOCATION OF POWER & DATA DEVICES. • REFER TO DESIGN /BUILD DOCUMENTS FOR SCOPE, TECHNICAL LAYOUT AND SPECIFICATIONS FOR EACH DISCIPUNE. 20. ARCHITECTS DOCUMENTS INDICATE LOCATION AND RELATIONSHIP OF DEVICES. COORDINATE EXACT LOCATION WITH FURNITURE VENDOR. 21. COORDINATE POWER /DATA, FIRE SAFETY DEVICES & LIGHT FIXTURE MOUNTING LOCATIONS WITH INTERIOR ELEVATIONS, FINISHES & CASEWORK. 22. PROVIDE EXTENSION RINGS AND MOUNTING ACCESSORIES WHERE REQUIRED FOR POWER /DATA DEVICES AND LIGHT FIXTURES. COORDINATE WITH INTERIOR FINISHES AND CASEWORK. 23. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 16500 - LIGHTING 1. LOCATION OF SWITCHES SHALL BE SHOWN ON THE REFLECTED CEILING PLAN. ALL SWITCHES SHALL BE MOUNTED AT A MAXIMUM HEIGHT OF 48" A.F.F. TO • MEET THE LATEST ACCESSIBIUTY CODES AND REGULATIONS. 2. WHERE MULTIPLE SWITCHES OCCUR IN A SINGLE LOCATION, ALL SWITCHES SHALL BE GANGED UON. 3. DOWN UGHTS SHOWN IN THE CENTER OF CEILING TILE WITHOUT DIMENSIONS ARE TO BE LOCATED IN THE CENTER OF CEILING TILE, UON. 4. REUSE ALL EXISTING B/S FLUORESCENT FIXTURES AS NEEDED PER DESIGN LAYOUT AND TO MEET LOCAL ENERGY CODE COMPLIANCE. VERIFY OR PROVIDE NEW LAMPS AND REPLACE FAULTY BALLASTS. 5. DESIGN OF ELECTRICAL TO BE PREPARED UNDER A SEPARATE PERMIT AS A DESIGN BUILD PROJECT. PERMIT DRAWINGS TO BE REVIEWED AND APPROVED IN WRITING BY LANDLORD PRIOR TO COMMENCEMENT OF WORK. 6. ALL OFFICE AREAS LESS THAN 300 SQ. FT. ENCLOSED BY WALLS OR CEILING- HEIGHT PARTITIONS, AND ALL MEETING AND CONFERENCE ROOMS, SHALL BE EQUIPPED WITH OCCUPANCY SENSORS, PER CODE. 7, DESIGN BUILD ELECTRICAL ENGINEERING DRAWINGS INDICATE: A. CIRCUITING AND WIRING OF UGHT FIXTURES, AND SWITCHES. B. LIFE SAFETY EQUIPMENT. C. LOCATION OF REQUIRED EMERGENCY LIGHT FIXTURES, D. LIGHT FIXTURE SPECIFICATIONS 8. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. A Tenant Improvement for: SABEY CORPORATION 12201 Tukwila International Blvd. Suite 400 , Seattle, WA 98168 Tenant: SABEY DATA CENTER Intergate East, Building 5-WEST CORRIDOR 3355 South 120th Place Seattle, WA 98168 All reproduction & intellectual property rights reserved c 2006 REVIEWED FOR CODE COMPLIANCE APPROVED JAN l fi 2008 City Of Tukwila . BUILDING DIVISION Professional seal No. Issue Description REVIEW/ PERMIT Drawn by: RW Reviewed by: KK 'Project No: ,07- 5B03 -00 PROJECT NOTES Date 12/21/07 .97.0X r .JAN O I1.)LJ PIS:! ��flT BEN i EN Original drawing is 24' x 36 ". Scale entities accordingly if reduced G.0.1 I I L AREA OF WOR4 a I rC 8 MI SWEET 5 +0 m )fl W[ LEGAL DESCRIPTION: LOTS 1 THROUGH 8, INCLUSIVE, IN BLOCK 5 AND LOTS 1 THROUGH 8, INCLUSIVE AND LOTS 25 THROUGH 32, INCLUSIVE, IN BLOCK 6 OF "RIVERTON ". A REPEAT OF RIVERSIDE INTERURBAN TRACTS, AS PER PLAT RECORDED IN VOLUME 13 OF PLATS, PAGE 36, RECORDS OF KING COUNTY: TOGETHER WITH THAT PORTION OF VACATED 34TH AVE. S. VACATED BY ORDINANCE NO. 8689 ON OCTOBER 10, 1988 LYING BETWEEN SAID BLOCKS 5 AND 6: TOGETHER WITH THAT PORTION OF THE SOUTH 1/2 OF VACATED SOUTH 124TH STREET, THAT PORTION OF THE NORTH 1/2 OF VACATED SOUTH 125TH, STREET AND THAT PORTION OF THE EAST' 1/2 OF VACATED 34TH AVENUE SOUTH WHICH, PURSUANT TO KING COUNTY ORDINANCE NO, 8893, ATTACHED TO SAID PARCEL BY OPERATION OF LAW: EXCEPT THEREFROM THAT PORTION OF LOTS 1 AND 2 IN BLOCK 5 OF "RIVERTON ", A REPLAT OF PART OF RIVERSIDE INTERURBAN TRACTS, AS PER PLAT RECORDED IN VOLUME 13 OF PLATS, PAGE 36, RECORDS OF KING COUNTY, LYING WESTERLY OF A LINE DESCRIBED AS FOLLOWS: BEGINNING AT A POINT ON THE WESTERLY BOUNDARY OF SAID LOTS 1 AND 2, SAID POINT BEING .100, FEET DISTANT SOUTHERLY FROM THE NORTHWEST CORNER OF SAID LOT 1; THENCE NORTHEASTERLY TO A POINT ON THE NORTHERLY BOUNDARY OF SAID LOT 1, SAID POINT BEING 30 FEET DISTANT EASTERLY FROM THE NORTHWEST CORNER OF SAID LOT 1 AND THE END OF THIS LINE DESCRIPTION; AND EXCEPT THE SOUTH 30 FEET OF LOTS 8 AND 25 IN SAID BLOCK 6 CONVEYED TO KING COUNTY FOR SOUTH 125TH STREET BY DEED RECORDED UNDER RECORDING NO. 8810200800: AND EXCEPT THE EASTERLY 10 FEET OF LOTS 1 THROUGH 8 IN SAID BLOCK 6, CONVEYED TO THE CITY OF TUKWILA BY DEED RECORDED UNDER RECORDING NO. 9203260787: SITUATED IN THE CITY OF TUKWILA, COUNTY OF KING, STATE OF WASHINGTON. APN #— 102304 -9069. Drawn by: RW JAN 1 6 2008 3355 S. 120TH PL. °I I LI d�l SOUTH 124TH STAFF T A Tenant Improvement for: SABEY CORPORATION 12201 Tukwila International Blvd. Suite 400 Seattle, WA 98168 Tenant: SABEY DATA CENTER Intergate East, Building 5-2ND FLOOR RR & CORR. 3355 South 120th Place Seattle, WA 98168 All reproduction & intellectual property rights reserved c 2006 REVIEWED FOR CODE COMPLIANCE APPROVED City Of Tukwila BUILDIK DIWISIO.l Professional seal No. Issue Description REVIEW/ PERMIT Project No: 07- 5807 -00 Reviewed by: KK Date 12/12/07 SITE PLAN LEGAL DESCRIPTOR , f L, J RczHIA € cLtri Original drawing is 24 x 36 Scale entities accordingly if reduced G.0.2 DEMOLITION SYMBOLS EXISTING CONSTRUCTION TO BE REMOVED I T EXISTING CONSTRUCTION .TO REMAIN. GENERAL DEMOLITION NOTES 1. REFER TO CONSTRUCTION PLAN AND CEILING PLAN FOR EXTENT OF DEMOLITION. 2. SAVE AND STORE All LIGHT FIXTURES. EXIT SIGNS, DOORS as HARDWARE FOR RE —USE, UON. • 3. SAVE ALL EXISTING PLUMBING FIXTURES FOR RE —USE, UNLESS OTHERWISE NOTED. 4. REMOVE ALL TELEPHONE, ELECTRICAL, AND DATA OUTLETS. FIXTURES, PANELS, ETC FROM ALL DEMOLISHED PARTmONS. REMOVE ALL CORRESPONDING CABLES, CONDUIT, WIRING, ETC. ALL THE WAY BACK TO THE ORIGINATING SOURCE, UON. 5. RELOCATE SECURITY DEVICES AS REQUIRED. KEYED SHEET NOTES REMOVE EXISTING NON ADA COMPLIANT RAMP AND HANDRAIL ASSEMBLY. EXISTING RAMP, MAY BE DEMOLISHED, RELOCATED OR REMAIN IN PRESENT LOCATION. VERIFY WTTH BUILDING MANAGEMENT. . REMOVE EXISTING PARTITION. REMOVE EXISTING CEILING ASSEMBLY AND LIGHTING. SEE REFLECTED CEILING PLAN FOR EXTENT OF DEMO. PROVIDE SELECTIVE DEMOLITION OF EXISTING RAMP TO FACILITATE CONSTRUCTION. SALVAGE DOOR FOR MANAGEMENT COMPANY REUSE IN THE FUTURE. AREA PLAN u - ten i REVIEWED COMPLIANCE CODE C APPROVE 3 t\ ILDING DIVISION dhl I 0 • /_' I✓i -ivit i ;;t=Eu IF3 t► DEMOLITION PLAN 0 8' 16' T L - TI 24' C❑ MATCH LINE DN. t► 1/8" = 1'- 0" DEMOLITION PLAN n 0 8' 16' 24' MATCH LINE 1 /Et" = 1'- 0" A Tenant Improvement for SABEY CORPORATION 12201 Tukwila International Blvd. Suite 400 Seattle, WA 98168 Tenant: . SABEY DATA CENTER Intergate East, Building 5 -2ND FLOOR RR & CORR. 3355 South 120th Place Seattle, WA 98168 All reproduction & intellectual property rights reserved c 2006 Professional 'seal No. Issue Description Drown by: R.W REVIEW/ PERMIT 12/12/07 Project No: 07-- 5807 -00 Reviewed by: KK DEMOLITION PLAN Original drawing is 24' x 36 ". Scale entities accordingly if reduced A.1.1 Dote DEMOLITION SYMBOLS = = EXISTING CONSTRUCTION TO BE REMOVED EXISTING CONSTRUCTION TO REMAIN GENERAL DEMOLITION NOTES 1. REFER TO CONSTRUCTION PLAN AND CEILING PLAN FOR EXTENT OF DEMOLITION. 2, SAVE AND STORE ALL LIGHT FIXTURES, BUT SIGNS, DOORS & HARDWARE FOR RE —USE, UON. 3. SAVE ALL EXISTING PLUMBING FIXTURES FOR RE —USE, UNLESS OTHERWISE NOTED. 4, REMOVE ALL TELEPHONE, ELECTRICAL, AND DATA OUTLETS, FIXTURES, PANELS, ETC FROM ALL DEMOLISHED PARTITIONS. REMOVE ALL CORRESPONDING CABLES, CONDUIT, WIRING, ETC. ALL THE WAY BACK TO THE ORIGINATING SOURCE, UON. 5. RELOCATE SECURITY DEVICES AS REQUIRED. KEYED SHEET NOTES O1 REMOVE EXISTING NON ADA COMPLIANT RAMP AND HANDRAIL ASSEMBLY. 2 EXISTING RAMP MAY BE DEMOUSHED, RELOCATED OR REMAIN IN PRESENT LOCATION. VERIFY WITH BUILDING MANAGEMENT. O REMOVE EXITING PARTITION. 'q> REMOVE EXISTING CEILING ASSEMBLY AND LIGHTING. SEE REFLECTED CEILING PLAN FOR EXTENT OF DEMO. O PROVIDE SELECTIVE DEMOLITION OF EXISTING RAMP TO FACILITATE CONSTRUCTION. 0. SALVAGE DOOR FOR MANAGEMENT COMPANY REUSE IN THE FUTURE. AREA PLAN Lrzn REVIEWED FOR * i CODE COMPLIANCE APPROVED. JAN 1. 6 2CJ00 City Of Tukwila B _ ILDING DIVISION Clang-iv elk n -rte t D CITY (14;vvIA JAN JAN I✓i�t�l�l;k E` N IC1� t► E DEMOLITION PLAN P icilmonmill UP BC DN i MATCH LINE UP a DEMOLITION PLAN MATCH LINE 0 8' 16' 24' 1/8" = 1' 0" 0 8' 16' I 24' 1/8" — = 1 0 A Tenant Improvement for: SABEY CORPORATION 12201 Tukwila International Blvd. Suite 400 Seattle, WA 98168 ' . Tenant: SABEY DATA CENTER Intergate East, Building 5 -2ND FLOOR RR & CORR. 3355 South 120th Place Seattle, WA 98168 All reproduction & intellectual property rights reserved c 2006 Professional seal No. Issue Description Dote REVIEW/ PERMIT 12/12/07 Drown' by: RI Reviewed by: KK Project No: 07— SB07 -00 DEMOLITION PLAN ' Original drawing is 24" x 36 ". Scale entities accordingly if reduced A.1.1 r • • • • WOMENS ROOM • 205 • • • • o • • N • • • MENS I ROOM ▪ 2T1 ■ • • s • ■ • ■ 3 — c.- • - f, - /v\aP 5 /4'r< / — � : � n� 1�-�y ' C� %–cam c.. n T\• c ' r .tea 3 — f /Ott A- . ` ALL /* A co e 1 HR RATED CORRIDOR 19' -6 t •r■ ■ ■■ ■ ■ ■■ M all ■M EIN CONSTRUCTION PLAN 0 4' 8' @ MOST RESTRICTIVE OBSTRUCTION IN CORRIDOR 1 HR RATED CORRIDOR I 204 12' 1/8" = 1'- 0" N P1 a Q] a Ui a a a a N N • O a • hJ O a a a -tr a N z x U i CO a x a a U, a a N w a a ✓ a ✓ a a a Cr, N Cr, CO r a a cv 2 st i - 4 U- J J p W z a a a a a a a N x a w a 2 -a a y P- 0- C m Y 3EL o w flDcp2 WA3 -�- \/! i 'r plc N � ye ru SYMBOL LEGEND • EXISTING CONSTRUCTION TO REMAIN I • - 1 ONE -HOUR RATED NON- STRUCTURAL PARTITION TO UNDERSIDE AT STRUCTURE ABOVE. SEE L /A.9.2. mEszazzzl NON - STRUCTURAL PARTITION TO UNDERSIDE OF GRID. SEE K /A.9.2. NON- STRUCTURAL PARTITION TO UNDERSIDE OF STRUCTURE. SEE J /A.9.2. NEW CASEWORK / MILLWORK GENERAL NOTES 1. REFER TO PROJECT NOTES FOR CONSTRUCTION REQUIREMENTS. 2. GENERAL CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDMONS PRIOR TO COMMENCEMENT OF WORK. 3. ALL INTERIOR PARTITION, PENETRATIONS, AND OTHER OPENINGS IN THE BUILDING SHELL SHALL BE SEALED, GASKETED, OR WEATHER STRIPPED AS REQUIRED TO MEET PARTITION RATINGS. 4. WHERE PARTITION LAYOUT INTERSECTS EXISTING SHELL /CORE GYPSUM BOARD, REMOVE EXISTING CORNER BEADS AND OTHER ACCESSORIES, ALIGN FACE OF PARTITIONS, TAPE & • SAND SMOOTH FOR NEW FINISH. 5. PROVIDE PARTITION ANCHOR BRACKETS FOR ALL CASEWORK, FIXTURES, EQUIPMENT, & DEVICES MOUNTED ON OR ATTACHED TO PARTITIONS. 6. -ALL WOOD USED IN INTERIOR FRAMING IS TO BE FIRE- RETARDENT TREATED WOOD UNO. 7. DOORS AND CASED OPENINGS WITHOUT DIMENSIONS OR DETAILS ARE TO BE LOCATED 4" FROM ADJACENT WALL OR MATCH EXISTING SUITE STANDARD. 8. ALL RESTROOMS SHALL HAVE FLOOR DRAINS. 9. AU PLUMBING WALLS TO HAVE GREEN BOARD. 10. REPAIR EXISTING WALLS AS REQUIRED. KEYED SHEET NOTES a t EXISTING 1 HOUR RATED WALL- FLOOR TO STRUCTURE ABOVE. FOR ACCESS FLOOR RAMP INFORMATION SEE J /A.9.1 & L /A.9.1. 3O CONSTRUCT PARTAON IN SAME LOCATION. AREA PLAN REVIEWED FOR CODE COMPLIANCE APPROVED JAN 1. e 2008 City Of Tukwila Bu ILDIN a DIVISION . I r '� C JA'yi. 17'LIns:,..I I t► Professional seal No. Issue Description Drawn by: RW A Tenant Improvement for: SABEY CORPORATION 12201 Tukwila International Blvd. Suite 400 Seattle, WA 98168 Tenant: SABEY DATA CENTER Intergate East, Building 5 -2ND FLOOR RR & CORR. 3355 South 120th Place Seattle, WA 98168 All reproduction & intellectual property rights reserved c 2006 REVIEW/ PERMIT 12/12/07 Project No: 07– SB07 -00 Reviewed by: KK CONSTRUCTION PLAN Date Original drawing is 24" x 36 ". Scale entities accordingly if reduced A.2A.1 LIGHTING SUMMARY LTG —SUM 2004 Info _ Project Mdre INTERGATE EAST BUILDING 5 Date 12/12/07 3355 S 120TH PLACE For Building Department Uoe SEATTLE, WA 98168 Applicant Name: BURGESS DESIGN INC. Applicant Address: 1326 5TH AVE, SUITE 500 SEATTLE WA 98101 , Applicant Phone: 206.587,7120 Project Description 0 New Building 0 AddI on El Alteration Compliance Option 0 Prescriptive I J Lightrg Pow Allowance 0 Systeme Maids (See Codification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box) 0 No chc ges are being mode to the lighting 0 Less limn 60% of the Tatra are nee and instaued kitting wattage is not been' increased MAXIMUM ALLOWED LIGHTING WATTAGE (INTERIOR) Location (floor /room no Occupancy Description Mowed Watts per S.F ss Area in S.F. Mowed X Area - B RESTROOM, CORRIDOR .8 2,251 1,801 " From Table 15-1 (aer) — document of exceptions • token from footnotes Total Allowed Watts 1,801 PROPOSED LIGHTING WATTAGE (INTERIOR) (Way not exceed Tots Mowed Watts for Interior) Location (floor /room no.) Fixture Description Number of Fixtures Watts Fixture Watts Proposed -- RECESSED FLUORESCENT CAN LIGHT 15 32 480 SURFACE MOUNTED FLUORESCENT (2)41 13 96 1,248 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 1,728 1 Ii %Ar//IO i ' - iir :a v e r y A riWIAr r "'a 4 ;21E41 remmirgAin I/E I � � �� // Q -- o v' .. Fl I %Jl /!!i /I \� minamm vn' ■m�i7 � 9' -0" AFF 1 r „ VAN O//iI!/.ifi N EMIE rir A l/ mr4, - 4=§ or A wl A Al A N !` AAr.41 P glEME MI '//. IV Ari OMB PP"MA fbro A OrMi pr ACT 9' -0" AFF MENS ACT ROOM • ❑ 1' -5" 9' -0" AFF REFLECTED CEILING PLAN MATCH LINE 0 , = 1'- 0" 0 8' 16' 24' ❑ CEILING LEGEND LIGHTING SYMBOL N = NEW SYMBOL DESCRIPTION /SPEC NEW BUILDING STANDARD 2' X 4' FLUORESCENT FIXTURE, 3 TUBE. NEW GWB CEILING / SOFFIT REFER TO PLAN FOR CEILING HEIGHT, UON. REFER TO DETAIL C/ k9.1 NEW BUILDING STANDARD RECESSED FLUORESCENT CAN LIGHT FIXTURE COORDINATE FINAL LOCATION W/ CODE OFFICIAL EXISTING EXIT SIGN TO REMAIN. COORDINATE WITH CODE OFFICIAL. NEW EXIT SIGN: MATCH EXTG. BUILDING STANDARDS. CEILING LEGEND -• CONTROLS DESCRIPTION NEW SWITCH LOCATION. GENERAL RCP SHEET NOTES 1. REFER TO PROJECT. NOTES FOR CONSTRUCTION REQUIREMENTS. 2. ARCHITECTURAL REFLECTED CEILING PLANS INDICATE TYPE AND LOCATION OF LIGHT FIXTURES REFER TO DESIGN BUILD ELECTRICAL DRAWINGS AND DESIGN BUILD LIFE SAFETY FOR COMPLETE REFLECTED CEILING PLAN DESIGN. 3. LIGHT SWITCHES ARE SHOWN FOR LOCATION AND DESIGN INTENT ONLY. REFER TO ELECTRICAL DESIGN BUILD FOR SPECIFIC LOCATION AND SWITCHING DIAGRAMS. 4. UNLESS NOTED OTHERWISE, MULTIPLE SWITCH'S IN A SINGLE LOCATION SHALL BE GANGED IN A SINGLE BOX AND COVERED WITH A SINGLE COVERPLATE. 5. ELECTRICAL SUB - CONTRACTOR IS RESPONSIBLE FOR PROVIDING CUT SHEETS TO BUILDING MANAGEMENT FOR ALL FIXTURES DESIGNATED AS NEW. 6. CONTRACTOR IS RESPONSIBLE FOR ALL FIRE SPRINKLER DESIGN. RELOCATE OR ALTER ALL FIRE SPRINKLER HEADS AS NECESSARY. 7. CONTRACTOR IS RESPONSIBLE FOR ALL EMERGENCY PATHWAY LIGHTING PER THEIR DESIGN /BUILD CONTRACT. KEYED SHEET NOTES O PLACE DOWNLIGHT AS CLOSE TO BEING CENTERED OVER TOILET OR SINK AS POSSIBLE. 0. NOT USED. O NEW CEILING GRID, TILES AND LIGHTING, SEE PLAN FOR HEIGHT. SEE C /A.9.1. O MECHANICAL CONTRACTOR TO COORDINATE INSTALLATION OF ROOM EXHAUST, HEATING VENTILATION AND FIRE LIFE SAFETY. O. FULL CEILING TILE. O NO CHANGE IN THIS AREA 7O CEILING HEIGHT TRANSITION. SEE J /A9.1. <> CONTRACTOR SHALL ALIGN NEW GRID WITH EXISTING GRID. REVIE OMpLIANCE CODE C APPROVE JAN 1 2g10B Cary Of Tukwila BUILDING [VISO LIGHTING SUMMARY 2004 Energy Code Compliance. Form FRAMING PLAN 0 8' 16' 24' A4 wmp ffir ffir A ry AN E ms/ / / / / / / � A �/� N j rl�m 'l NoPA re A r A r A s�ricr� IOJllr i Er AN // /%/% A AF, sir iu ��G�11!!!�I% i//J' N Er A Er ,/ swAr Er E Am, %j liLl� I� rf/. • %G A E A FAME E `'�// V %% Gr ier , " Er Auk _Pr mm-- ErAwAm MATCH LINE 1/8" = 1' - Professional sect No. Issue 'Description A Tenant Improvement for. SABEY CORPORATION 12201 Tukwila International Blvd. Suite 400 Seattle, WA 98168 Tenant: .• SABEY DATA CENTER Intergate East, Building 5 -2ND FLOOR RR & CORR. 3355 South 120th Place Seattle, WA 98168 All reproduction & intellectual property rights reserved c 2006 • REVIEW/ PERMIT 12/12/07 Drawn by: RW Reviewed by: KK Project No: 07- SB07 --0O REFLECTED CEILING PLAN ciT! F.:'Ji •vfp-ti 0 I Ut_I\I l EF3 Dote Original drawing is 24" x 36 ". Scale entities accordingly if reduced A.2B.1 LIGHTING SUMMARY LTG —SUM _ 2004 Project Info Project kdress: INTERGATE EAST BUILDING 5 Date 12/12/07 3355 S 120TH PLACE For BuAding Deportment use . . SEATTLE, WA 98168 Applicant Name: • BURGESS DESIGN INC. Applicant Address: 1326 5TH AVE, SUITE 500 SEATTLE WA 98101 Applicant Phone: 206.587.7120 Project Description 0 New Buikling 0 Addition II Attmike Compliance Option 0 Prescriptive ' II Power. Allowance 0 (See thclification Checklist (over). indicate PrescripCne do LPA spaces clearly on plans.) Nteraticn Exceptions (check appropriate box) 0 No doges are being made to the lighting its Own 6ax of the fixtures are new and installed lotting wattage Is not Meng increased MAXIMUM ALLOWED UGHTING WATTAGE (INTERIOR) Location (flaw /room no Occupancy Description • Allowed Watts per S.F u` Area in S.F. Mowed X Area - B RESTROOM, CORRIDOR .8 2,251. 1,801 n From Table 15-1 (over) — document all exceptions taken from tootnotes Total Allowed Watts 1,801 PROPOSED UGI-ITING WATTAGE (INTERIOR) ' (slay not exceed To Allowed Watts for tnteriar) Location (flaw /room no.) Fixture Description Number of Fixtures. Watts Fbchue Watts Proposed - RECESSED FLUORESCENT CAN LIGHT 15 32 480 SURFACE MOUNTED FLUORESCENT (2'X4') 13 96 1,248 Total Proposed Watts may not exceed Total Mowed Watts for Interior Total Proposed Watts 1,728 CEILING LEGEND SYMBOL N N =NEW SYMBOL DESCRIPTION /SPEC NEW BUILDING STANDARD 2' X . 4' FLUORESCENT FIXTURE,; 3 TUBE. NEW GWB CEILING / SOFFIT REFER TO PLAN FOR CEILING HEIGHT, UON. REFER TO DETAIL C/ A.9.1 NEW BUILDING STANDARD RECESSED FLUORESCENT CAN UGHT FIXTURE LIGHTING f:A COORDINATE FINAL LOCATION W/ CODE OFFICIAL EXISTING EXIT SIGN TO REMAIN. COORDINATE WITH CODE OFFICIAL NEW EXIT SIGN: MATCH EXTG. BUILDING STANDARDS. CEILING LEGEND CONTROLS DESCRIPTION NEW SWITCH LOCATION. GENERAL RCP SHEET NOTES 1. REFER TO PROJECT NOTES FOR CONSTRUCTION REQUIREMENTS. 2. ARCHITECTURAL REFLECTED CEILING PLANS INDICATE TYPE AND LOCATION OF LIGHT FIXTURES REFER TO DESIGN BUILD ELECTRICAL DRAWINGS AND DESIGN BUILD LIFE SAFETY FOR COMPLETE , REFLECTED CEILING PLAN DESIGN. 3. LIGHT SWITCHES ARE SHOWN FOR LOCATION AND DESIGN INTENT ONLY. REFER TO ELECTRICAL DESIGN BUILD FOR SPECIFIC LOCATION AND SWITCHING DIAGRAMS. . 4. UNLESS NOTED OTHERWISE, MULTIPLE SWITCH'S IN A SINGLE LOCATION SHALL BE GANGED IN A SINGLE BOX AND COVERED WITH A SINGLE COVERPLATE, 5. ELECTRICAL SUB - CONTRACTOR IS RESPONSIBLE FOR PROVIDING CUT SHEETS TO BUILDING MANAGEMENT FOR ALL FIXTURES DESIGNATED AS NEW. 6. CONTRACTOR IS RESPONSIBLE FOR ALL ARE SPRINKLER DESIGN. RELOCATE OR ALTER ALL FIRE SPRINKLER HEADS AS NECESSARY. 7. CONTRACTOR IS RESPONSIBLE FOR ALL EMERGENCY PATHWAY LIGHTING PER THOR DESIGN/BUILD CONTRACT. KEYED SHEET NOTES O PLACE DOWNUGHT AS CLOSE TO BEING CENTERED OVER TOILET QR SINK AS POSSIBLE. Q NOT USED. O NEW CEILING GRID, TILES AND LIGHTING. SEE PLAN FOR HEIGHT. SEE C /A.9.1. 4O MECHANICAL CONTRACTOR TO COORDINATE INSTALLATION OF ROOM EXHAUST, HEATING VENTILATION AND FIRE UFE SAFETY. <:/ FULL CEILING TILE O NO CHANGE IN THIS AREA. . 7O CEILING HEIGHT TRANSITION. SEE J /A.9.1. . O CONTRACTOR SHALL ALIGN NEW GRID WITH DASTING GRID. City u1li1a BUILD114G P SIOI\ L LIGHTING SUMMARY 2004 Energy Code Compliance Form 205 IA 206 11 111111■ •1111 •1 A 0 ' r oxa A 1...,..., 4.4 w r--,, M //`r+ r#111, ir �wrra2/ . 4� ja cirrMI r $ :Ati u #� 010...1 : :an "'/ Et r W.4ra II r��r" MAjg WA, MN irArfte T wora 4 ammo AIM OS E 1111 MIME VESTIOU I 9' -0" AFF ACT NMI PAr rd ill I or J o p m • imv/I raiii weerczara Er AN rN N PrreArd f � Ir.�frci! M E Er Ai I'/, idl /AN! AN � U % l O �� / ri r " EV � N =1 r.A I/r N %/S! /r %1� , , 10 - 0 " AFF N : TYP. UP DN. a cD WOMENS ROOM ACT 9' -0" AFF MENS CT ROOM 0 1' -5" 3' -6" 9' -O" AFF REFLECTED CEILING PLAN 8' 16' 24' /, / / / /// Il MATCH LINE A CIA pome f%!��/�/ /� � my A Al Or • 1 I NM Mr A r r Ari OVA 0 1132 1 orwt Irmo We A � lwlEi Er Ar, rreAA ArA Er AN rAr Er m r irI F IN Er AN Or Brea Er A Ag or 41 Er ;A ,r ½ 2 li // l/ �� //1'//� rd=r4 FRAMING PLAN 0 8' 16' 24' . P. MATCH LINE TYR 1/8" = 1'- 0" A Tenant Improvement for: SABEY CORPORATION 12201 Tukwila International Blvd. Suite 400 Seattle, WA 98168 • . Tenant: . . SABEY DATA CENTER Intergate East, Building 5 -2ND FLOOR RR & CORR. 3355 South 120th Place Seattle, WA 98168 All reproduction & intellectual property rights reserved c 2006 Professional seal No. Issue Description Date Drawn by: RW REVIEW/ PERMIT 12/12/07 Project No: 07- SB07 ---00 Reviewed by: KK REFLECTED CEILING PLAN cm Original drawing is 24" x 36". Scale entities accordingly if reduced B • .. • , 7, 7 V N 4 01IM ■ ■ ■■■■■■■■ ■ ■■ r ■ MI ROOM • • • ■ ■ ■ ■ ■ • MEN'S ROOM • • 206 • • • ■ ■ ■ ■ I ■ Aft ■ ACCESSORIES SYMBOL SYMBOL <I.JR -1j Gam FIXTURE ADA- COMPLIANT LAVATORY FAUCET DELTA 3549 -WF HGMHDF JANITOR SINK FAUCET CHICAGO FAUCETS 540- 897SWXF COUNTER - MOUNTED SOAP DISPENSER BOBRICK B -8221 SURFACE- MOUNTED TOILET SEAT COVER DISPENSER BOBRICK B-4221 SURFACE - MOUNTED MULTI -ROLL TOILET TISSUE DISPENSER BOBRICK B -2740 SURFACE -- MOUNTED SANITARY NAPKIN DISPENSER BOBRICK 8- 435009 PARTITION MOUNTED, SANITARY NAPKIN DISPOSAL BOBRICK, B -270 SEMI - RECESSED PAPER TOWEL DISPENSER AND TRASH RECEPTACLE BOBRICK B -4394Y GRAB BAR @ 36' x 1 1/2' BOBRICK 6806 SERIES GRAB BAR @ 42 X 1 1/2" BOBRICK B -6806 SERIES OR SIMILAR. VERTICAL GRAB BAR @ 18 X 1 1/2" BOBRICK B -6806 SERIES TOWEL HOOK, BOBRICK B7677 OR SIMILAR EQUIPMENT FIXTURE ADA- COMPLIANT DRINKING FOUNTAIN ELKAY EBFATLR -8 (COMBINATION) ADA- COMPLIANT URINAL - AMERICAN STANDARD ALLBROOK URINAL 6541.132 MANUAL FLUSH VALVE- SLOAN ROYAL MODEL 186 -1 LOW CONSUMPTION ADA-- COMPLIANT TOILET- AMERICAN STANDARD AFWALL ELONGATED FLUSH VALVE TOILET 2257.103 MANUAL FLUSH VALVE - SLOAN ROYAL MODEL 111 LOW CONSUMPTION ADA COMPLIANT COUNTER MOUNTED LAVATORY MATCH BUILDING STANDARD JANITOR SINK MATCH EXISTING CONDITION, OR REUSE IF POSSIBLE KEYED SHEET NOTES O1 PROVIDE NEW POWER OUTLET, PLUMBING, AND WALL BRACING • FOR WALL HUNG DRINKING FOUNTAIN COMBINATION. O NEW VCT FLOORING, RUBBER BASE AND PAINT TO MATCH EXISTING FLOOR STANDARDS, UON, PROVIDE ELECTRIC STRIKE AND CARD READER FOR BUILDING MANAGEMENT CARD READER. COORDINATE WITH BUILDING MANAGEMENT, €:; PROVIDE ELECTRIC STRIKE AND CARD READER FOR TENANTS DOOR. COORDINATE WITH TENANT. O PROVIDE RESTROOM AND JANITOR CLOSET SIGNAGE. COORDINATE WITH BUILDING MANAGEMENT. 6O VERIFY RELOCATION REQUIREMENTS OF SECURITY, PHONE, CAMERA AND CARD READERS. GENERAL NOTES 1. REFER TO PROJECT NOTES FOR CONSTRUCTION REQUIREMENTS. 2. ELECTRICAL SUB - CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE WORKING CONDITION OF AIL EXISTING OUTLETS NOTED TO REMAIN. 3. ALL OUTLETS. SHOWN ARE APPROXIMATE. DUE TO HIDDEN CONDITIONS ADDMONAL P /P /D MAY EXIST BUT. NOT BE REFLECTED ON THE PLANS. 5, TOILET PARTITIONS SHALL BE HADRIAN FLOOR MOUNTED PARTITIONS, COLOR #603 ALMOND MATCH EXISTING BUILDING STANDARD 6. P -TRAP COVERS ARE WHITE, COORDINATE WITH BUILDING MANAGEMENT. 7. ALL PLUMBING FIXTURES ARE WHITE 8., ALL FAUCETS ARE TO BE POLISHED CHROME FINISH. 9. ALL RESTROOMS SHALL HAVE FLOOR DRAINS, MATCH EXISTING BUILDING STANDARD. 10. ALL TOILET SEATS SHALL BE OLSONITE 10CC • OR APPROVED EQUAL 11. EACH TOILET RECEIVES A TOILET SEAT COVER DISPENSER. BOBRICK B -4221, AND TOILET PAPER DISPENSER, BOBRICK B -2740, COORDINATE FINAL LOCATION WITH BUILDING MANAGEMENT. . 12. ALL WOMEN'S RESTR00M TOILETS TO RECEIVE SND -2, COORDINATE FINAL LOCATION WITH BUILDING MANAGEMENT. 13. VERIFY INSTALLATION REQUIREMENTS OF SURFACE MOUNT VERSUS RECESSED ACCESSORIES WITH ROOM CONDITIONS. 14, PROVIDE B/S CRACK SUSPENSION MEMBRANE AND WATERPROOFING @ ALL FLOORS AND DRAINS. 15. CLOTHES HOOKS FOR TOILET PARTITIONS: BOBRICK 13-7677, COORDINATE FINAL LOCATION WITH BUILDING MANAGEMENT. ELECTRICAL WALL MOUNTED DEVICES SYMBOL N GA SYMBOL ` B-1 I I cT -1 I CT-2 I CT -3 CT -4 I R -1 I lvcr I P -2 I DESCRIPTION DUPLEX OUTLET ( # DENOTES MOUNTING HT IN INCHES) CARD READER -- VERIFY ALL REQUIREMENTS WITH TENANT. DENOTES A NEW DEVICE DENOTES A GROUND FAULT INTERRUPT CIRCUIT - LOCATED AT SINKS. FINISH SPECIFICATIONS r4g-v. ;vIVClu I CODE COMPLIANCE MANUFACTURER BASE City Of Tukwila ROPPE CERAMIC TILE DALTILE FLOOR TILE DALTILE WALL TILE AMERICAN OLEAN ACCENT AMERICAN OLEAN ACCENT NORA ARMSTRONG BENJAMIN M00RE BENJAMIN MOORE BENJAMIN MOORE DESCRIPTION I JAN t F 20018 4'h COVED RUBBER BASE. 120' ROLLED I LD DIVJEQLI COLOR: MATCH BUILDING STANDARD TILE SPEC: BUFFSTONE jDK -147, SEAL PER MFR. RECOMMENDATIONS. GROUT COLOR: MATCH BUILDING STANDARD, W/ CLEAR GROUT SEAL. TRANSITION STRIP: MATCH BUILDING STANDARD TILE SPEC: GLAZED TILE CT. DOVE D -725, SEAL PER MFR. RECOMMENDATIONS. GROUT COLOR: MATCH BUILDING STANDARD, W/ CLEAR GROUT SEAL TRANSnTON STRIP: MATCH BUILDING STANDARD TILE SPEC: MATTE PARK ASPEN #54, SEAL PER MFR. RECOMMENDATIONS. GROUT COLOR: MATCH BUILDING STANDARD, W/ CLEAR GROUT SEAL. TRANSITION STRIP: MATCH BUILDING STANDARD TILE SPEC: MATTE CORAL #56, SEAL PER MFR. RECOMMENDATIONS. GROUT COLOR: MATCH BUILDING STANDARD, W/ CLEAR GROUT SEAL TRANSITION STRIP: MATCH BUILDING STANDARD RUBBER MATT FLOORING NORAMENT 925 COLOR: TBD VINYL COMPOSITION TILE 12" X 12" STANDARD EXCELON 1/4 TURNED. COLOR: MATCH EXISTING BUILDING STANDARDS OR CONDITIONS PAINT BUILDING ELEVATOR LOBBY AND HALLWAY GWB EGGSHELL FINISH COLOR: MATCH EXISTING BUILDING STANDARD RESTOOM/ SHOWER ROOM WALLS AND CEILING MATCH EXISTING BUILDING STANDARD FINISH TYPE COLOR: MATCH EXISTING METAL FRAME SEMI -GLOSS FINISH COLOR: MATCH EXISTING BUILDING STANDARD GENERAL FINISH NOTES 1. REFER TO ELEVATIONS AND DETAIL SHEETS. 2. CENTER TRANSITION BETWEEN MATERIALS UNDER DOOR PER DETAILS. 3, REFER TO G /A.9.3 FOR ENLARGED FLOOR PLAN, 4. CEILING GRID AND TILE - MATCH EXISTING CONDITIONS. P.,E F!VED I-, rI.A ,IAN D PL i:vli I (;Lz I tR 0 MINN ■■■■■■■ ■ ■■■ ■ ■rte 4' 8' 12' C 1 HR RATED CORRIDOR I 204 VCT-11 MATCH LINE UP DN. ELEVATOR VESTIBULE 201 ,NA EQUIPMENT/ ELECTRICAL/ FINISH PLAN 1/8" = 1'— 0" B El EQUIPMENT/ ELECTRICAL/ FINISH PLAN 0 4' 8' 12' MATCH LINE 1/8" = 1'— 0" A Tenant Improvement for. SABEY CORPORATION 12201 Tukwila International Blvd. Suite 400 Seattle, WA 98168 . Tenant: SABEY DATA CENTER Intergate East, Building 5-2ND FLOOR RR & CORR. 3355 South 120th Place Seattle, WA 98168 All reproduction & intellectual property rights reserved c 2006 Professional seal No. Issue Description Drawn 'by: RW Reviewed by: KK Project No: 07 SB07 -00 EQUIPMENT ELECTRICAL/ FINISH PLAN Date REVIEW/ PERMIT 12/12/07 Original drawing is 24" x 36 ". Scale entities accordingly if reduced A.2C.1 DOOR & HARDWARE GENERAL NOTES 1. SEE HARDWARE SPECIFICATIONS FOR HARDWARE, TYPES AND INSTALLATION. 2. DOOR WIDTH & HEIGHT ARE NOMINAL DIMENSIONS FROM JAMB TO JAMB AND FINISH FLOOR TO BOTTOM OF FRAME HEAD. REFER TO SPECIFICATIONS FOR CLEARANCES. 3. DOUBLE DOOR NOMINAL WIDTH INDICATES 2 DOOR LEAVES OF EQUAL WIDTH, U.O.N. 4. DOOR CONSTRUCTION SHALL PROVIDE ATTACHMENT OF ALL HARDWARE WITHOUT THROUGH — BOLTS. 5. DOOR / HARDWARE SHALL COMPLY WITH ALL APPLICABLE IBC & ACCESSIBILITY . REQUIREMENTS. DOOR SCHEDULE 202 203A 2036 205 206 DOOR S--0" 6' - 0" 6' —O" 3 ,_ 0 " 3' -0" 7' -0" V -0 T -O' 7 , -0 " A B B A HARDWARE GROUP HARDWARE GROUP G PAIRED ENTRY LOCKSET NON —RATED GROUP 2 SINGLE, STOREROOM LOCKSET NON —RATED GROUP 3 RESTROOM ENTRY DOOR TYPES 1 WIDTH I , A �( 2 1 1 3 HM HM HM . HM HM NR 20 MIN 20 MIN NR NR DOOR TO BE PAINTED TO MATCH WALL COLOR DOOR TO BE PANTED TO MATCH WALL COLOR DOOR TO BE PANTED TO MATCH WALL COLOR DOOR FINISH TO MATCH BUILDING STANDARD, REFER TO FLOOR 1 DOOR FINISH TO MATCH BUILDING STANDARD, REFER TO FLOOR 1 HARDWARE 1 ENTRY FUNCTION LOCKSET 2 PAIR HINGES 1 AUTOMATIC FLUSH BOLT 1 DUST PROOF STRIKE 1 ASTRAGAL — FULL — LENGTH 2 DOOR CLOSERS 1 COORDINATOR — FULL— LENGTH OR SEQUENCER 2 FLOOR— MOUNTED DOOR STOPS 1 SMOKE SEAL 1 STOREROOM FUNCTION LOCKSET 2 PAR HINGES 1 WALL— MOUNTED DOOR STOP 1 0—PULLS 1 PUSH PLATES 1 CLOSER PANTED HOLLOW METAL FRAME PANTED FLUSH S.C. HOLLOW METAL DOOR E = EXISTING, MATCH ALL EXISTING CONDITIONS REMARKS ACCESS CONTROL SYSTEM (BY OTHERS) SYSTEM SHALL COMPLY WITH INTERNATIONAL BUILDING CODE SECTION 1008.1.3.4 AND ANY LOCAL REQUIREMENTS. SEE EXAMPLE ON 3RD FLOOR, WIDTH B PANTED HOLLOW METAL FRAME FLUSH S.C. HOLLOW METAL DOOR 20 MINUTE RATED ASSEMBLY REVIEWED FOR CODE COMPLIANCE APPROVED JAN 1 Ei 20QB City Of Tukwila 3 ILDING .DIVISION J C?T: JAN 0 -zr1vit viv I ER A NOTE: uzn COORDINATE ANCHOR BRACKET LOCATIONS W/ CASEWORK & EQUIPMENT WHERE SCHEDULED, AND MANUF. MOUNTING INSTRUCTIONS A,9.1 NOTES: 1. TYPICAL ANCHOR BRACKET ASSEMBLY FOR HANDRAILS, GRAB BARS & TOILET ACCESSORY ANCHORAGES. 2. COORDINATE ANCHOR BRACKET LOCATION WITH ACCESSORY MANUFACURER MOUNTING INSTRUCTIONS. 12" VCT VCT -1 ADA RAMP ELEVATION PROVIDE MIN 25 GA STUDS & ANCHOR BRACKET ANCHORAGES. DOUBLE STUDS END OF PARTITIONS. 3-18 PAN HEAD SHT. MIL. SCREWS 6x16 GA UNPUNCHED STUD TRACK WITH FLANGES COPED AT VERTICAL STUDS. ATTACH TO TWO STUDS MIN. & EXTEND 6"MIN BEYOND MOUNTING POINT EACH DIRECTION. TYPICAL MTL, STUD ANCHOR BRACKET ANCHOR BRACKET: 6"X16ga UNPUNCHED STUD TRACK, ATTACH TO 3 STUDS MIN TYPICAL ANCHOR BRACKET FRAMING PROVIDE METAL TRANSITION STRIP FROM MATT TO VCT. R -1 FINISHED FLOOR NTS BOTTOM OF FINISHED CEILING NTS 1/4 " =1' -0" DEVICES SHOWN STACKED IN PLAN ARE TO ALIGN VERT. AS SHOWN BELOW M END OF RAMP 1 -1/2" 0 PAINTED TUBE STEEL HANDRAIL WITH SUPPORT 8' -0" O.C. BLOCK SOLID. RUBBER MATT FLOORING ACCESS FOR PROVIDE MAX SLOPE 1:12 p TRANSITION S 1 AT LOCATION AS DIMENSIONED ON PLAN; OR NEXT TO DOOR / OPENING AS DIMENSIONED BELOW FIRE ALARM STROBE FRAME WHERE OCCURS ROOM SIGNAGE, ETC, THERMOSTAT LIGHT & PROJECTION SCREEN SWITCHES, WALL MOUNTED OCCUPANCY SENSOR di LEI CARD READER WHERE OCCURS 1. LOCATED SWITCHPLATES, ELECTRICAL AND TELEPHONE WALL OUTLETS AT NEAREST STUD FROM SCALED LOCATION ON PLAN, UNLESS SPECIFICALLY DIMENSIONED ON PLAN, ELEVATION, OR LOCATION AS PER DIAGRAM ABOVE. 2. CENTER FIRE ALARM STROBES DIRECTLY ABOVE ARE EXTINGUISHER CABINETS WHERE BOTH OCCUR. GENERAL DEVICE ALIGNMENT ACT CEILING CO 1 D' -0" 1 2" HARDWARE LATCH FINISHED FLOOR TELEPHONE OUTLET ELECTRICAL OUTLET ETURN, TO PARTITION HANDRAIL REQURED ON BOTH SIDES VERTICAL OF ACT MATERIAL ACT CEILING 1 O'-0" NTS e B -1 4" RUBBER BASE CROSS RUNNER MAIN RUNNER DISTANCE FROM BRACING WIRES TO CROSS RUNNERS NOTE: PROVIDE ACT SUSPENSION GRID TO COMPLY WITH IBC SECTION 1621 MINIMUM STANDARD PER SECTION 9.6 ASCE7. VERIFY REQUIREMENTS WITH CITY OFFICIALS. w W 12 GA. BRACING WIRE WITH MINIMUM 4 TIGHT TURNS IN 1 1/2" BOTH ENDS OF WIR —TYP, ACT SEISMIC BRACING DIAGRAM L • 'Aa Q VERIFY IN FIELD INTERFACE SEA. 12 GA. VERTICAL HANGER WIRE AT 4'-0" EACH WAY WITH MINIMUM 3 TIGHT TURNS IN 1 1/2" BOTH ENDS OF WIRE A ti COLUMN FURRING. DETAIL VCT AS SCHEDULED ACCESS FLOOR PANEL IN UNDERSTRUCTURAL SYSTEM ACCESS FLOOR PEDESTAL ASSEMBLY ATTACH PER MANUFACTURES SPEC. DUSTING STRUCTURAL CONCRETE SEISMIC COMPRESSION STRUT 2 1/2" X 25 GA METAL STUDS ® 24" OC, TO 9' -9" MAX HEIGHT. STUDS TO BE INSTALLED TO 6" ABOVE GWB CEILING. BRACE STUDS TO STEEL COLUMN AS REQUIRED. DESIGNER TO COORDINATE STUD SIZE /SPACE IF GREATER HEIGHT IS REQ'D 1 LAYER 5/8" TYPE "X" G.W.B. ONE SIDE ONLY. G.W.B TO BE INSTALLED TO 6" ABOVE GWB CEILING. METAL RUNNER TRACK WITH POWER DRIVEN FASTENEERS © 24" OC .1" AR POCKET COLUMN CONFIGURATION MAY BE DIFFERENT N.13/151920115.11.141111 NTS, N.T.S. INTERFACE AF IS BASIS OF DESIGN. MATCH EXISTING CONDITIONS AND VERIFY MANUFACTURER HAS UL LISTING. TYPICAL ACCESS FLOORING DETAIL LJ - L I i N.T.S. A Tenant Improvement for SABEY CORPORATION 12201 Tukwila International Blvd. Suite 400 Seattle, WA 98168 Tenant SABEY DATA CENTER Intergate East, Building 5 -2ND FLOOR RR & CORR. 3355 South 120th Place Seattle, WA 98168 All reproduction & intellectual property rights reserved c 2006 . Professional seal No Issue Description ,REVIEW/ PERMIT 12/12/07 Drawn by: RW Reviewed by: KK Project No: 07- 5B07 --00 DOOR SCHEDULE / DETAILS Date Original 'drawing is 24" x 36 ". Scale 'entities accordingly if reduced A.9.1 HEAD DEATIL 1/4' v 1 0" 4" 8" 12" 1/2" 0" 4" 8" 12" 20' FLOOR TO FLOOR EXISTING CONCRETE /STEEL DECK. 1/2" CLR. 18 GA. CONT. VERT SLOTTED DEFLECTION TRACK w/ 1/4" 0 RAWL "ZAMAC" NAIL —IN FASTENERS ® 2' -0" (EMBED 1 -1/8" MIN.) BOTTOM OF STRUCTURE SEALANT ATTACH GWB TO METAL STUDS SEE STRUCTURAL A /A.9.2 LONG LEG TOP TRACK CEILING AS SCHEDULED 2 1/2' X 20 GA. METAL STUDS STUDS 0 24" OC, TO 12' -3" MAX. HEIGHT SEE M /A.9,2 FOR STRUCTURAL REQUIREMENTS. 1 LAYER OF 5/8" TYPE "X" GYP. BD. EA. SIDE OF METAL STUDS. INSULATION UON ON PLANS POWDER DRIVEN FASTENER 0 24 "oc SEE STRUCTURAL B/A.9.2 MET RUNNER TRACK SEALANT CONCRETE SLAB NTS NON -RATED FLOOR TO DECK PARTITION 3" = 1'-0 B - SILL DETAIL ' 0" 4'" 8" 12" BOTTOM OF STRUCTURE 4" 8" CONT. 20 GA. TRACK W/ 1/e 0 RAWL 7AMAC" NAIL —IN FASTENERS. 2"X2"X12" MIN. LEG AT STRUCTURE — ATTACH W 2 POWDER DRIVEN F ERS PER BRACE OR OTHER APPROVED METHOD PLENUM HEIGHT OF 5'-0" OR LESS 2 1/2 "x25 GA METAL STUD BRACING 0 8' -0" OC TO STRUCTURE DIRECTION ALTERNATE. PARTITIONS PERPENDICULAR TO PARTITION ACT AS BRACE PLENUM OF 5'-0" TO 10' -0" SHALL USE NESTED OR BACK TO BACK 3 -1/2" 25 GA. STEEL STUDS. ABOVE 10' -0" OR PLENUM. CONTACT ARCHITECT FOR ADDMONAL INFORMATION. MAX PARTITION WEIGHT 15Ibs. /P.S.F. SUSPENDED CEILING AS SCHEDULED VERIFY B/S HEAD CONDITION 3/8" CONT. FOAM SOUND ISOLATION TAPE TAPEABLE MET. TOP TRACK ATTACHED TO BRACING W/2 SELF— TAPJING SM. SCREWS 48 oc, 3/4 PIPE SLEEVES 2 1/2" X 25 GA METAL STUDS ' 24" OC, TO 14' —D" MAX. HEIGHT. 1 LAYER 5/8" TYPE "X" GYP. BD. EE.AA.. SIDE OF METAL STUDS POWDER DRIVEN FASTENER ® 24" OC MET. RUNNER TRACK SEALANT CONCRETE SLAB EXISTING CONCRETE SLAB NTS NON -RATED FLOOR TO CEILING PARTITION 3 " = I' -0" 12" v MAN DOOR OPENING DOUBLE 600 S 162 -33 0 MA DOOR JAMBS (TYP.) HEADER ELEVATION DOOR HEADER DETAIL HEADER SECTION BUILT —UP HDR 2 -600 S- 162 -33 W/ CONT TRACK T &B W/ #8 012 "0.C. IN 4 PLACES EXTEND WEBS ATTACH EA. SIDE EA. STUD WITH 3 #8. CONT. 20 GA. TRACK W. 2 #8 EA. STUD 0" 4" 8" BOTTOM OF STRUC FIRE RATED SEALANT ALL PENETRATIONS TO HAVE FIRE CAULKING 0 OR FIRE DAMPERS AS NECESSARY. NO VERTICAL PENETRATIONS OCCUR IN NEW CONSTRUCTION SLOTTED LONG LEG TOP TRACK SYSTEM, SUCH AS STEELER INC DFT DEFLECTION TRACK CEILING AS SCHEDULED SEE STRUCTURAL A/A.9.2 INSULATION WHERE NOTED ® WALL TYPE: ®oo JOINT COMPOUND BOTTOM TRACK, WITH POWER DRIVEN ATTACHMENT° SEE STRUCTURAL B/A:92 RATING NO.: UL U419 4" 8" 12" RATING NO.: UL U419 ONE -HOUR RATED PARTITION • NTS CHANNEL SHAPED, FABRICATED FROM MIN 25 MSG CORROSION — PROTECTED STEEL, MIN. WIDTH TO ACCOMMODATE STUD SIZE, WITH MIN. 1' LONG LEGS, ATTACHED TO FLOOR AND CEILING WITH FASTENERS 24" OC. MAX. CHANNEL SHAPED, FABRICATED FROM MIN, 25 MSG CORROSION- PROTECTED STEEL, MW WIDTH 2 -1/2" 2OGA, MIN 1-1/4" FLANGES AND 1/4 RETURN, SPACED 16" 00. STUDS TO BE CUT 3/8" TO 3/4' LESS THAN ASSEMBLY HEIGHT. SEE STRUCTURAL A /A.9.2. MINERAL WOOL BATTS OR GLASSFIBER WITH UL CLASSIFICATION MARKINGFRICTTON FITTED BETWEEN STUDS AND RUNNERS. MIN. THICKNESS 1 -1/2 ". GYPSUM PANELS WITH BEVELED, SQUARE OR TAPERED EDGES, APPUED VERTICALLY OR HORIZONTALLY. VERTICAL JOINTS CENTERED OVER STUDS AND STAGGERED ONE STUD CAVITY ON OPPOSITE SIDES OF STUDS. VERTICAL JOINTS IN ADJACENT LAYERS. (MULIILAYER SYSTEMS) STAGGERED ONE STUD CAVITY. HORIZONTAL JOINTS NEED NOT BE BACKED BY STEEL FRAMING. HORIZONTAL EDGE JOINTS AND HORIZONTAL BUTT JOINTS ON OPPOSITE SIDES OD STUDS NEED NOT BE STAGGERED. HORIZONTAL EDGE JOINTS AND HORIZONTAL BUTT JOINTS IN ADJACENT (MULTI — LAYERED SYSTEMS) STAGGERED A MIN OF 12 ". PROVIDE ONE LAYER TYPE'X' 5/8" THICK PER SIDE. TYPE S OR 5 -12 STEEL SCREWS USED TO ATTACH PANELS TO STUDS (ITEM 2) OR FURRING CHANNELS (ITEM 6). SINGLE LAYER SYSTEMS: 1" LONG FOR 1/2" AND 5/8" PANELS OR 1 -1/4" LONG FOR 3/4" THICK PANELS, SPACED 8 " OC. WHEN PANELS ARE APPLIED HORIZONTALLY, OR 8" OC. ALONG VERTICAL AND BOTTOM EDGES AND 12" OC. IN THE FIELD WHEN PANELS ARE APPLIED VERTICALLY. VINYL OR CASON, DRY OR PREMIXED JOINT COMPOUND APPUED IN TWO COATS TO JOINTS AND SCREW HEADS OF OUTER LAYERS. PAPER TAPE, NOM 2' WIDE, EMBEDDED IN FIRST LAYER OF COMPOUND OVER ALL JOINTS OF OUTER LAYER PANELS. PAPER TAPE AND JOINT COMPOUND MAY BE OMIIILO WHEN GYPSUM PANELS ARE SUPPLIED WITH A SQUARE EDGE. SEE D /A.9.2 FOR STRUCTURAL REQUIREMENTS, 12" 3" =1' -0" PER CALCULATIONS BY ENGINEERS NW DATED 12.12.07 1. STRUCTURAL REQUIREMENTS SUPERSEDE OTHER REQUIREMENTS. 2. ALL FULL HEIGHT STUDS 0 24" 0.C. MAX. W/ 2 #8 EA END OF SILL, 3. PROVIDE DOUBLE' STUDS @ ALL MAN. DOOR OPENINGS. 4. TOTAL SPAN OF STUDS SHALL BE NO MORE THAN 22-8" IN HEIGHT. 5; ALL PARTITIONS ARE NON— BEARING. 6. SEE CALCULATIONS FOR DESIGN CRITERIA. 7. PROVIDE DETAIL .0 /A.9.2 AT ALL DOORS W/ FULL HEIGHT WALLS. STRUCTURAL NOTES 0" 4" 8" 12" NTS REY--EV11ED FOR CODE COMPLIANCE APPROVED JAN 1 h 2008 City Of Tukwila 8 ILDING DIvISTN_ C UF,i\I 0 )!J A Tenant Improvement for: SABEY CORPORATION 12201 Tukwila Intemational Blvd. Suite 400 Seattle, WA 98168 Tenant: SABEY DATA CENTER Intergate East, Building 5-2ND FLOOR RR & CORR. 3355 South 120th Place Seattle, WA 98168 All reproduction & intellectual property rights reserved c 2006 Prafessiondl seal No. Issue Description REVIEW/ PERMIT 12/12/07 Drawn by: RW Reviewed by: KK Project No: 07- 5B07 -00 WALL DETAILS Date Original drawing is 24" x 36 ". Scale entities accordingly if reduced A.9.2 I71' F J iii '1 • ., IraMerragerigarmr,dmiffarar.gwrig ��, • ri d CT -4 ACCENT WALL TILE, CENTER OVER PLUMBING FIXTURES, TYP. CT -3 ACCENT WALL TILE. / ELEVATION RESTROOM �HJ u2n r CT-2 WALL TILE. RETURN CT -2 ON PERPENDICULAR WALL TO EXTEND ONE FULL TILE BEYOND NEW TOILET PARTITION NEW STALL PARTITIONS MIRROR S.S MIRROR CHANEL 2 X 2 ALUMINUM SUPPORT 0 SIDE AND BACK WALL INSTALL FLUSH WITH SURFACE OF CLEATS CT -1 0) N TYP. RESTROOM SINK AND COUNTER 39 " -41" <TPD CA B -2 > W.C. ,> ■ ■ ■_ ■�■■ ■■■ ■■ NUM. MN AX Z GB -3 21" L- 1 WALL — MOUNTED LIGHT FIXTURE, WHERE OCCURS 0 LAV: P =LAM SUPPORT 0 24" O.C. MAX 3/8 ' -0 " <161‘ NON HC ACCESSIBLE URINAL d w in 0 NON HC ACCESSIBLE W.C. PLUMBING FIXTURE ACCESSORY MOUNTING HT. N.T.S. V) PROVIDE & INSTALL MIRROR TO RUN LENGTH OF WALL. PROVIDE & INSTALL LAVATORY, COUNTERTOP, FAUCET, AND SOAP DISPENSERS, CT -2 WALL TILE AND COVED BASE PER FINISH SCHEDULE. HC ACCESSIBLE W.C. n O N) 8" MIN MIN DI PTH F 6" MAX TOE CLEARANCE TYPICAL ABBREVIATIONS AC CH GB PM SCD SD SND WOMENS ROOM MENS ROOM 306 305 ENLARGED FLOOR PLAN <TPD AE SSIBL! ACCESSIBLE COAT HOOK GRAB BAR PAPER TOWEL DISPENSER SEAT COVER DISPENSER SOAP DISPENSER SANITARY NAPKIN DISPOSAL SNV . SANITARY NAPKIN VENDOR TPD TOILET PAPER DISPENSER PTD/WR PAPER TOWEL DISP.IWASTE REC. ' 1/4" = 1' -0" I NOTE 1 I J Q O r) N 4 1 HR RATED CORRIDOR II 303 BUBBLER EWC EWC KEYED SHEET NOTES O PROVIDE FULL— HEIGHT BUILDING STANDARD MIRROR ALONG LENGTH OF COUNTERTOP AND STARTING ABOVE COUNTERTOP (BOTTOM MAX HEIGHT 40'). REFER TO ELEVATION A /A.9.2 FOR ADDMONAL INFORMATION 2O PROVIDE CT -2, CT -3, AND CT-4 AT PLUMBING WALLS, REFER TO ELEVATION FOR ADDITIONAL INFORMATION. 3� PROVIDE BULLNOSE WALL TILE AT TILE STOPPING POINT. O PROVIDE INSTANT —FLOR WATER HEATER S -80 AND ALL REQUIRED . ELECTRICAL AND PLUMBING. COORDINATE WITH BUILDING MANAGEMENT. PLASTIC LAMINATE COUNTERTOP, APRON AND SUPPORT BRACING. CONTRACTOR SHALL MODIFY AS REQUIRED FOR NEW LAYOUT. COORDINATE WITH BUILDING MANAGEMENT IF INVENTORY IS AVAILABLE FOR REUSE. O BUILDING STANDARD JANITOR FLOOR SINK. PROVIDE NEW FAUCET AND FRP WALL FINISH AT WET WALLS. 1. FOR CALLOUTS SEE A.2C.1 FIRE EXTINGUISHER CABINET REVIEWE. CODE COMPLIANCE A P P ROVED 3,N 16 TAB �� Cf Tukwila . BUILDING DIVISION ER A Tenant Improvement for: SABEY CORPORATION 12201 Tukwila International Blvd. Suite 400 Seattle, WA 98168 Tenant: SABEY DATA CENTER Intergate East, Building 5-2ND FLOOR RR & CORR. 3355 South 120th Place Seattle, WA 98168 • All reproduction & intellectual property rights reserved c 2006 Professional seal No. Issue Description REVIEW/ PERMIT 12/12/07 Drown by: RW Reviewed by: KK Project No: 07— SBO7 -00 ELEVATIONS / DETAILS Date Original drawing is 24 x 36 ". Scale entities accordingly if reduced A.9.3