Loading...
HomeMy WebLinkAboutPermit PG08-021 - WESTFIELD SOUTHCENTER MALL - TEAVANATEAVANA 856 SOUTHCENTE MALL Parcel No.: 6364200010 Address: Suite No: Cityabf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PLUMBING /GAS PIPING PERMIT 856 SOUTHCENTER MALL TUKW Permit Number: Issue Date: Permit Expires On: PG08 -021 06/09/2008 12/06/2008 Tenant: Name: TEAVANA Address: 856 SOUTHCENTER MALL , TUKVVILA WA Owner: Name: WEA SOUTHCENTER LLC Address: 11601 WILSHIRE BLVD , LOS ANGELES CA Contact Person: Name: JAMES MOORE Address: 833 SE MAIN #242 , PORTLAND OR Contractor: Name: B & R PLUMBING INC Address: PO BOX 4069 , SPANAWAY WA Contractor License No: BRPLUI *099DF Phone: Phone: 503 - 577 -8859 Phone: 253 847 -5770 Expiration Date: 03/13/2010 DESCRIPTION OF WORK: TENANT IMPROVEMENT OF NEW MALL SPACE, 3 COMPARTMENT SINK, 3 HAND SINKS, 1 FLOOR DRAIN including INSTALLATTION OF A REDUCED PRESSURE PRINCIPLE ASSEMBLY (RPPA) AND A GREASE TRAP IN PLACE OF GREASE INTERCEPTOR. Value of Plumbing /Gas Piping: $9,000.00 Uniform Plumbing Code Edition: 2006 Fees Collected: $202.60 International Fuel Gas Code Edition: 2006 FIXTURE TYPE AND OUANTITY Plumbing Bathtub or combination bath/shower 0 Bidet 0 Clothes washer, domestic 0 Dental unit, cuspidor 0 Dishwasher, domestic, with independent drain 0 Drinking fountain or water cooler (per head) 0 Food -waste grinder, commercial 0 Floor drain 1 Shower, single head trap 0 Lavatory 0 Wash fountain Receptor, indirect waste 1 Sinks 3 Urinals 0 Water Closet 0 0 Plumbing (cont.) Building sewer and each trailer park sewer 0 Rain water system - per drain (inside bldg) 0 Water heater and /or vent 1 Industrial waste treatment interceptor, including its trap and vent, except for kitchen type grease interceptors 0 Repair or alteration of water piping and/or water treatment equipment 1 Repair or alteration of drainage or vent piping 0 Medical gas piping system serving (1 -5) inlets /outlets for a specific gas 0 Medical gas piping (6 +) inlets /outlets 0 Gas Piping Gas piping outlets (0 -5) 0 Gas piping outlets (6 +) 0 * *continued on next page ** doc: UPC -10/06 PG08 -021 Printed: 06-09 -2008 City lo Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: PG08 -021 Issue Date: 06/09/2008 Permit Expires On: 12/06/2008 Permit Center Authorized Signature: Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit dam- not presume to giv authority to violate or cancel the provisions of any other state or local laws regulating construction or the pe Signature: e of work. I . - au,- orized to sign and obtain this plumbing /gas piping permit. Date: - C Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -10/06 PG08 -021 Printed: 06-09 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: TEAVANA • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 856 SOUTHCENTER MALL TUKW PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: PG08 -021 ISSUED 01/17/2008 06/09/2008 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: ** *PUBLIC WORKS DEPARTMENT CONDITIONS * ** 14: Due to installation of a GREASE TRAP in place of a GREASE INTERCEPTOR applicant shall follow Westfield's Southcenter Grease Trap Maintenance Program dated January 30, 2008 and maintain a Grease Trap Log. 15: Reduced Pressure Principle Assembly (RPPA) shall be installed per manufacturers specifications. doc: Cond -10106 PG08 -021 Printed: 06-09 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: Date: U C� ordinances governing or local laws regulating doc: Cond -10/06 PG08 -021 Printed: 06-09 -2008 CITY OF TUKWI Community Developmen epartment Permit Center 6300 Southcenter Bli/d., Suite 100 Tukwila, WA 98188 httpLiwww.ci. tukwila.wa.us P AN 17 2008 pEs tvit ukiNTEh Plumbing/G/PPermit No. TGO ro 9 Project No. :•.- ..:„ (For office i:the .only) ... .. PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax **Please Print** SITE LOCATION Site Address: )S'(Q SOU-kit-CA41X- King Co Assessor's Tax No.: Tenant Name-M A\M.. Property Owners Name: L2 Mailing Address: Suite Number: Floor: C- \ C- City New Ten? : Yes E] ..No k vvkimul State Zip 'CONT._AC.T PERSON,,-7Whii,clo we contacti.whe*yourpermitis-.1reitlfio'be isfled — • Name: Mailing Address: Day Telephone: S.-0 c _774 Ki5 242_ r-Yr-k7 6172B il Address: CLate-b 4tir City State Zip E-Ma PLUM", fiVIN CO'°- .16V/1A% Fax Number' " ri-CG g 6 Company Name: Mailing Address: Contact Person: E-Mail Address: Contractor Registration Number: City State Zip Day Telephone: Fax Number: Expiration Date: ,SRCHFIVV) 4-1; Company Name: • Mailing Address: 141,„:A.Iliptans !gust bewetstampeaby irciitect of Record (gAkb) 2-Et City State Zi Contact Person: Day Telephone:-3 14 14) Fax Number: E-Mail Address: • s ".i..'..., --.,..,11,94.4401111,0:4210,0414-01.0(0)yg414eerF■Ofitee.Ord • it. ,.: • ... ...,c, , '''. ''.:':'::]:.Vii,i4::'!'4.-.7:'.,:4,1 - ' '''' ' • '. “ '''''' . -,',..-::;,. - — - --II] 4.), -.-',-2: - ' 7 "L ..q.A.T'AtItiftg, : -;e. _:. '‘..' ' ' ' ' ".,..geri."-T1:;W:-." ",'''-f ip;..th," ' ' . "7 -"Z• ;."' : ; " :' Company Name: Mailing Address: Contact Person: E-Mail Address: QAApplicationsTorms-Applic.ations On Line U-2006 - Plumbing-Gas Piping Permit Application.doc Revised: 4-2006 bh City Day Telephone: Fax Number: State Zip Page 1 of 2 Valuation of Project (contractor's bid price): $ CO Scope of Work (please provide detailed ' rmation): 3 Coves 3 Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: -6C.CriV344 Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type: Qty Fixture Types. Qty Fi tiire Type: Qty = Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste r M1 r�� �C� n Vi f 1 Clothes washer, domestic Floor drain 'C Sinks 3 l Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent I Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and /or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 international Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 N O UTHORIZED AG Signaturq!� \�... Print Name:L MOO Mailing Address: .C.>> Y� vL Date: )7 d� D y Telephone: t 7 rl l' S 5-9 2�4Z Porgy (11(— CCU] 3 City State Zip Date Application Accepted: Date Application Expires: 7 0 Staff Initials: ze I Q :\Applications\Forms- Applications On Line3-2006 - Plumbing -Gas Piping Perini Application.doc Revised: 4.2006 bh Page 2 of 2 Parcel No.: 6364200010 Address: Suite No: Applicant: TEAVANA City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 856 SOUTHCENTER MALL TUKW RECEIPT Permit Number: Status: Applied Date: Issue Date: PG08 -021 ISSUED 01/17/2008 06/09/2008 Receipt No.: R08 -02426 Initials: User ID: JEM 1165 Payment Amount: Payment Date: Balance: $60.00 07/07/2008 12:10 PM $0.00 Payee: B & R PLUMBING, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check ACCOUNT ITEM LIST: Description 2806 60.00 Account Code Current Pmts PLUMBING - NONRES 000.322.103.00.0 60.00 Total: $60.00 4498 07/07 9711 TOTAL 60.00 doc: Receiot -06 Printed: 07 -07 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: PG08 -021 Address: 856 SOUTHCENTER MALL TURIN Status: APPROVED Suite No: Applied Date: 01/17/2008 Applicant: TEAVANA Issue Date: Receipt No.: R08 -02024 Initials: BLH User ID: ADMIN Payment Amount: $167.60 Payment Date: 06/09/2008 11:22 AM Balance: $0.00 Payee: B & R PLUMBING INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 2792 167.60 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLUMBING - NONRES 000.322.103.00.0 167.60 Total: $167.60 3423 06/09 9711 TOTAL 167.60 rtnr.• RAr.Aint -OR Print' f OR- 04200R City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: PG08 -021 Address: 856 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 01/17/2008 Applicant: TEAVANA Issue Date: Receipt No.: R08 -00165 Initials: WER User ID: 1655 Payment Amount: $35.00 Payment Date: 01/17/2008 02:15 PM Balance: $167.60 Payee: PRECISION PERMIT SERVICE TRANSACTION LIST: Type Method Description Amount Payment Check 5386 35.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES .• p J: ";;d 1 „ 25r1 CG DEVLLOP ;'C J 000/345.830 35.00 Total: $35.00 7377 01/17 9710 TOTAL 713.99 doc: Receiot -06 Printed: 01 -17 -2008 INS ICTION RECORD • -� Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ' C 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 /-,68-021 Project: Type of Inspection: /2 A / / / — P / 1 1 5 7 ,909•/,9 Addrg5ss6 /714 // Date Called: Special Instructions: ` Date Wanted: 7% Si- d 8 a.m. Requester: 'Tsc A : JAA C I2((. Phone No: 7/ —61/' 37/7 /$ v ( ® Approved per applicable codes. Corrections required prior to approval. COMMENTS: I'lvr.. . -,5 r. ‘ r P k ek'F /a<— egr '! Cif :COW teh n 51,1",:t /. sit I. 1-4. 'Tsc A : JAA C I2((. • /$ v ( nspector: Date: ❑ $60.00'RtINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: _ O. _S. siA.ats,a,.a. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit 1,448 -62/ PERMIT NO. (206)431 -3670 Project: Type of Inspection- ., / 2 i I - Al )/r 6 ' / 4 9 t l j g i t 1 Address:, 0-6 17.7 )9I/ Date Called: _' Special Instructions: Date Wa nted: 6 -/7- e a.mY„ p.m. Requester: P /•d --'6 :77/7 7 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: 46/01 ❑ $60 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: bate: _ 1-1 _ _ .r a. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit /'',v °42/ PERMIT NO. (206)431 -3670 Project: Type of inspection: Address:// Date Called: Special Instructions: Date W nted: -- // - 4) c...., a CND" 5 Requester: Phone No .7G4 - C.`1- 7612 / Approved per applicable codes. El Corrections required prior to approval. COMMENTS: • n s pector: Date ❑ $60.0 INSPECTION FEE REQUIRED. Prior to inspection, fee must be paid 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 4 !Date: CROSS - CONNECTION SPECIALISTS, LLC P.O. Box 731933 Puyallup; WA 98373 BACKFLOW PREVENTION ASSEMBLY TEST REPORT NAME: Tal SERVICE ADDRESS: 11, J W cLQ _ _ t�(C�IJ -I-(u, W64- L 0 ` LOCATION: r \ o ( e S_ I Y\ (1.7-A C L (6 vv., .,, CROSS CONNECTION CONTROL FOR: -pre tiA (SQ-iuftC A. TYPE ASSEMBLY: K P_P I MANUFACTURER: (. ` S 'MODEL: l 1443 SIZE: 314 LINE PRESSURE IS. PS I ASSEMBLY IS: NEW ❑ EXISTING ❑ REPLACEMENT C OLD SERIAL # (253) 840 -2501 Fax: (253) 840 -0886 Cell: (253) 318 -3156 P -() SERIAL NO: / ► 2 3c 3 Pressure Drop Accross No. 1 Check Valve _ - U_. p( psid Relief Valve Opened— - - — p(_.p psid No. 1 Check: Closed tight Leaked ❑ No. 2 Check: Closed tight Leaked ❑ Minimum A/G present Yes - No XPassed Test: Yes /� No No. 1 Check: Closed tight ❑. Leaked ❑ No. 2 Check: Closed tight - ❑ Leaked ❑ Passed Test: Yes No -- psid psid Air Inlet: Opened psid Failed to open Check Valve-- - - psid Leaked Passed Test: Yes No Pressure Drop Accross No 1 Check Valve psid Relief Valve Opened _ psid No. 1 Check: Closed tight I 1 Leaked -- ❑ No. 2 Check: Closed tight Leaked ❑ Minimum A/G present Yes No Passed Test: Yes No No. 1 Check: Closed tight ❑ psid Leaked - - - - -- ❑ No. 2 Check: Closed tight - psid Leaked -- -- - ❑ Passed Test: Yes No Air Inlet: Opened psid Failed to open Check Valve: - psid Leaked - - 1 I Passed Test: Yes No Is this a proper installation? YES — NO Approved Assembly? YES / NO Water Service fou d QN OFF W ter Service left ON Confined Space (hSl Cka OtAk 4 tC- 1e S — I C x V& J (1 ct c Remarksi y •� // Air Gap Inspection: Supply Pipe Diameter: _ Separation Pass ❑ Fail ❑ Midwest 845 11040153 Test Equipment: Make Used Watts Model TK99E Serial# 243078 Calibration Date ❑ Midwest 844P 05021825 I CERTIFY THE ABOVE REPORT TO,. TRUE: Nancy Perry ( §na �1 B 2463 Date'') ( o S Initial Test By: Cert. No u Signature Repaired By: -- Cert. No PE:RRYNJ94909 Date Repair Test By: - -- - - - Cert. No - B2463 Date — - --- Signature �l 0 hh / . 7 07/20/07 06 -05 -2008 JAMES MOORE 833 SE MAIN #242 PORTLAND OR 97213 Ciy of Tula Jim Haggerton, Mayor Department of Community Development Jack Pace, Director RE: Permit Application No. PG08 -021 856 SOUTHCENTER MALL TUKW Dear Permit Applicant: In reviewing our current permit application files, it appears that your permit application applied for on 01/17/2008 , has not been . issued by the City of Tukwila Permit Center. Per the Uniform Plumbing Code and/or International Fuel Gas Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and void. Your permit application expires on 07/15/2008 . If you choose to pursue your project, a written request for extension of your application addressed to the Building Official, demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 07/15/2008. If it is determined that an extension is granted, your application will be extended one time only, for an additional 180 days from the expiration date. In the event we do not receive your written request for extension, your permit application will become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, fer Marshall 't Technician xc: Permit File No. PG08 -021 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 • PERMIT COORD COPY PLAN REVIEW /ROUTH ' G SLIP ACTIVITY NUMBER: PG08 -0021 PROJECT NAME: TEAVANA DATE: 6 -9 -08 SITE ADDRESS: 856 SOUTHCENTER MALL Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # X Revision # I After Permit Issued DEPARTMENTS: Sul g DFJ1sio TERM6 (NATION OF COMPLETENESS: (Tues., Thurs.) Fire Prevention Structural Complete Comments: Incomplete ❑ Planning Division ❑ Permit Coordinator ❑ DUE DATE: 6 -10 -08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS RO TING: Please Route Structural Review Required ❑ REVIEWER'S INITIALS: No further Review Required ❑ DATE: APPROVALS OR CORRECTIONS: DUE DATE: 7 -8-08 Approved Approved with Conditions 1111 Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28-02 PERMIT COORD COPY PLAN REVIEW /ROUTI G SLIP ACTIVITY NUMBER: PG08 -021 PROJECT NAME: TEAVANA SITE ADDRESS: 856 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DATE: 01 -17 -08 DEPARTMENTS: I✓2 Bul ng-Divlsion Public Wor, kw, 21114-0 Fire Prevention Structural n Planning Division Permit Coordinator RMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 01 -24-08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: nNo further Review Required DATE: n APPROVALS OR CORRECTIONS: Approved Notation: Approved with Conditions DUE DATE: 02 -21 -08 Not Approved (attach comments) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 PROJECT NAME: Teo vavut- SITE ADDRESS: rSb S .C- /441,11 ORIGINAL ISSUE DATE: to-q,or • PERMIT NO: 1C 0 02 REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS STAFF INI IALS T Summary of Revision: L( -9 -af -Ii-- 61-6 214 in Summary of Revision: ���19 [ i ? Q VA k -k /),-- 51 Cvi Q KV Received b% k /76 ,.,,¢,c,� REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) • City of Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 4/ leig Plan Check/Permit Number: P6' or -� D Z� El Response to Incomplete Letter # ❑ Response to Correction Letter # [' Revision # / after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: T.e.d vim-, Project Address: Y54; 6.6.2,- /17419-. -. /721/ 7 :l<LUi` 98'/ S-'i Contact Person: fl'1ii - ,/4. .. Phone Number: (2-v6 —4.e>7/ Summary of Revision: Rey, SAC- be {A.» '� r - /7 /41yi /raj %2r, — eg,;S.24.( it - 6; Pl4-r) — 4,45 , /v e, F ®u% em � \JUR Sheet Number(s): P /I) "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on lf' -1 \applications\forms- applications on Iine\revision submittal Created: 8 -13 =2004 Look Up a Contractor, Elects an or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. License Information License BRPLUI *099DF Licensee Name B & R PLUMBING INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601278647 Ind. Ins. Account Id #3 Business Type CORPORATION Address 1 P 0 BOX 4069 Address 2 City SPANAWAY County PIERCE State WA Zip 98387 Phone 2538475770 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 3/6/1991 Expiration Date 3/13/2010 Suspend Date Separation Date Parent Company Previous License BRPLUC* 132CZ Next License Associated License Business Owner Information Name Role Effective Date Expiration Date HOWARD, DEBRAH A Cancel Date 01/01/1980 Bond Amount TIBBITTS, JOHN B #3 01/01/1980 629946 HOWARD, RICK L Until Cancelled 01/01/1980 0 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #3 CBIC 629946 02/27/2002 Until Cancelled $12,000.00 03/08/2002 Page 1 of 3 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= BRPLUI *099DF 06/09/2008 Wstflefrf Southcenter T REASEI AP MAI IE,ON.CEI WSOI i4M ' `' ` '�" 'JANUARY 3072008 PURPOSE: The intent of this program is to provide maintenance guidelines for any new food -use retailer utilizing a grease trap in place of a grease interceptor so as to minimize health, safety and environmental concerns. POLICY: All new retailers utilizing a grease trap in place of a grease interceptor will be required to contract the services with a Landlord- required grease waste contractor. Each store will have their grease trap maintained (as per the details below) a minimum of every two months. Proof of service should be kept on -site as well as copied to the mall management office (directly from the contractor). There shall also be placed on -site (and available at Landlord's request), a grease trap maintenance log which the contractor will complete upon each bi- monthly service. PROCEDURE: Below is the procedure for grease trap cleaning and recycling to be provided by a required vendor (see sample proposal attached): 1. Removal of all waste from grease traps. 2. Contractor will utilize a portable pumping system when necessary. 3. The grease traps will be backfilled after cleaning to insure proper draining. 4. Contractor will not use any biodegradable or chemicals that might temporarily break up grease but lead to re- coagulating later on. 5. An inspection and service report will be left at each location. 6. Customers will be required to provide a regular cleaning schedule. 7. All customers will be contacted prior to each service. 8. Westfield will be included with a copy of the services by email or fax. at,114 8 ` COMPLIANCE Fines will be levied for non - compliance. If our Maintenance Engineers or contracted vendor is denied access to the space during the scheduled removal or during an emergency removal, a $100 fine for each instance will be levied for each occurrence. PG 08-021 Dear Andrew, Baker Commodities Inc. would like to thank you for consideration or our company: Our goal is to provide the best possible service for your grease trap needs. As per our conversation we can schedule and maintain all of your new locations needs. Services for the grease traps will include: • Removal of All Waste from the grease traps. • All waste is pumped into a holding tank on our trucks and then brought back to our plant for onsite recycling. • If trap is too far from the truck we use a portable pumping system. • This system is then wheeled back to the truck and pumped into our holding tank. • The grease traps will be backfilled after cleaning to insure proper draining. • Baker Commodities Inc. does not use, sell, handle, or recommend the use of chemicals and /or "bio- degradable" products. • Please advise the restaurant owners that you do not want these types of product used. • An inspection and service report will be left at each location. • Customers will be required to provide a regular cleaning schedule. • All customers will be contacted prior to each service. • Westfield will be included with a copy of the services by e-mail or fax. If you have any question or concerns please do not hesitate to give us a call @ 206 - 243 -7387 Thanks, Jim Hodge Baker Commodities Inc. Seattle Division BAKER COMMODITIES INC. NAY and Pni4... Waddwide P.O. Box 58368, Seattle, WA 98138 (206) 243-73 FAX (206) 243 -3412 CA-021 Grease Trap Log Retailer Name: Space Number: Contractor Signature Date Amount of Grease Removed Repairs /Remarks 1 PLUNGING GENERAL NOTES ALL PLUMBING WORK TO COMPLY WITH ALL APPLICABLE CODES AND LANDLORD CRITERIA. ALL HOT AND COLD PIPING AND FITTINGS SHALL BE INSULATED WITH 1/2" THICK SNAP ON FIBERGLASS INSULATION WITH CANVAS JACKET COVER COLD WATER PIPING INSULATION SHALL INCLUDE VAPOR BARRIER JACKET SEALED WITH CEMENT. STERILIZATION OF DOMESTIC WATER SYSTEM. BEFORE BEING PLACED IN SERVICE ALL WATER LINES SHALL BE CHLORINATED TO THE SATISFACTION OF THE ENGINEER IN ACCORDANCE WITH AWWA SPEC C60 -53T. PROVIDE ACCESSIBLE SHUT —OFF VALVES AT ALL PLUMBING FIXTURES. WATER VALVES TO BE JENKINS #476 OR EQUAL. INSTALL SHOCK ABSORBERS ON ALL HOT AND COLD WATER BRANCH LINES TO PLUMBING FIXTURES AND EQUIPMENT. SANITARY AND VENT PIPING SHALL BE SERVICE WEIGHT CAST IRON NO —HUB WITH CAST IRON FITTINGS WITH STAINLESS STEEL NO —HUB COUPLINGS NEOPRENE GASKET. NO PVC PIPING IS PERMITTED. SOLDER JOINT FITTINGS USING 95 -5 LEAD FREE SOLDER. WATER PIPING ABOVE GRADE SHALL CONSIST OF TYPE "L" HARD COPPER TUBING WITH WROUGHT COPPER FITTINGS USING SILVER SOLDER. INSTALL WATER METER AS REQUIRED BY APPLICABLE CODES, UTILITY COMPANY, AND LANDLORD REQUIREMENTS. ESCUTCHEONS: PROVIDE EXPOSED PIPING, BOTH BARE AND COVERED WITH CP CAST BRASS ESCUTCHEONS WHERE PASSING THROUGH FLOORS, CEILINGS, WALLS OR PARTITIONS. SUPPORT HORIZONTAL DRAINAGE PIPING AT LEAST EVERY 5' —O" OR AT EVERY HUB, COPPER TUBING EVERY 7' -0" AND STEEL PIPE EVERY 10' -0" WITH CLEVIS HANGER AND INSULATION PROTECTION SHIELDS. PIPING SHALL NOT BE SUPPORTED FROM BRIDGING OR OTHER PIPING. TEST PIPING AND PROVE TIGHT FOR AT LEAST TWO HOURS IN ACCORDANCE WITH REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION AND OR AS SPECIFIED, TEST SHALL BE PERFORMED IN THE PRESENCE OF THE TENANT REPRESENTATIVE AND LOCAL INSPECTOR TEST SHALL BE REPEATED IF NECESSARY UNTIL FINAL APPROVAL OF SYSTEM IS OBTAINED. TEST DRAINAGE AND VENT PIPING BY FILLING WITH WATER TO OVERFLOWING. WATER LEVEL TO REMAIN CONSTANT. TEST WATER PIPING WITH WATER 13 TIMES THE WORKING PRESSURE. ALL SANITARY SEWER LINES TO BE SLOPED AT MINIMUM 1/4" PER FOOT. ALL PLUMBING FLOOR PENETRATIONS MUST HAVE "LINK SEALS" INSTALLED BEFORE MEMBRANE IS INSTALLED. EXPOSED HORIZONTAL WATER PIPING SHALL BE INSTALLED IN ACCORDANCE WITH LOCAL HEALTH DEPT. CODE. PROVIDE WATER METER, REMOTE REGISTER READ IN CUBIC FEET, EASILY ACCESSIBLE TO MALL PERSONNEL LOCATE IN BATHROOM OR STOCK ROOM. INTERIOR GREASE TRAP SIZING DIMENSIONS OF EACH BOWL OF 3— COMPARTMENT SINK TOTAL CAPACITY OF 3—COMPARTMENT SINK (TOTAL OF 3 BOWLS) CAPACITY IN GALLONS (DIVIDE BY 231) ACTUAL DRAINAGE LOAD (75% OF TOTAL CAPACITY) FLOW RATE FOR 1 MINUTE FLOW RATE FOR 2 MINUTE 16 "x 19 "x 13.5" 16" x 19" x 13.5" 16" x 19" x 13.5" 12,312 CUBIC INCHES 53.3 GAL 40 GAL 40 GPM OR 80 LBS. 20 GPM OR 40 LBS. (2 LB. RETENTION = 1 GPM /FLOW) *ZURN GREASE INTERCEPTOR MODEL GT2700 -25 HANDLES 25 GPM AND PROVIDES 50 LBS. OF CAPACITY. LANDLORD NOTES ALL TENANTS ON THE GROUND FLOOR REQUIRING BELOW GRADE WORK SHALL COORDINATE WITH LANDLORD PRIOR TO ANY SLAB DEMOLITION. TENANT SHALL COORDINATE WITH LANDLORD TO PROVIDE OPPORTUNITY FOR SPECIAL INSPECTION AND PHOTOGRAPHIC DOCUMENTATION BY LANDLORD. OF BELOW GRADE WORK PRIOR TO THE COVERING UP OF SUCH WORK. TENANT SHALL BE RESPONSIBLE FOR RECONSTRUCTION AND PATCHING OF THE SLAB —ON —GRADE SYSTEM, INCLUDING GRAVEL LAYERS, VAPOR BARRIER, AND CONCRETE. 2. ALL FOOD SERVICE AND EXCESSIVE WATER USE TENANTS SHALL BE REQUIRED TO INSTALL A COLD WATER SUBMETER ASSEMBLY (REGISTERING IN GALLONS) WITH PRESSURE REGULATOR, GROUND JUMPER WIRE AND ALL FURTHER INSTALLATIONS AND CONNECTIONS, IN ACCORDANCE WITH ALL GIVEN REQUIREMENTS AT THE REAR PORTION OF THE TENANT SPACE IN A READILY ACCESSIBLE LOCATION, AT A MAXIMUM (48 ") ABOVE THE FINISHED FLOOR. 3 LANDLORD PROVIDED A CAPPED SANITARY VENT CONNECTION LOCATED WITHIN OR ADJACENT TO THE TENANT SPACE IN THE CEILING, VERIFY EXACT LOCATION IN FIELD. TENANT IS RESPONSIBLE TO EXTEND FROM THEIR SPACE TO POINT OF CONNECTION AT TENANT'S EXPENSE. 4. TENANT'S CONTRACTOR SHALL VERIFY POINTS OF CONNECTION FOR ALL VENT, SEWER, AND WATER PIPING WITH MALL MANAGEMENT BEFORE PROCEEDING WITH WORK. TENANT I5 RESPONSIBLE FOR EXTENDING PIPING FROM POINT OF EXISTING CONNECTIONS TO TENANT SPACE AT TENANT'S EXPENSE. 5. TENANT TO SUBMIT FOR CODE VARIANCE REGARDING GREASE TRAP INSTALLATION REQUIREMENTS. 0 WATER FILTER FOR ICE MACHINE AND HOT WATER MACHINE. LOCATE IN STOCK AREA IN EASILY ACCESSIBLE LOCATION. O EXTEND AND CONNECT NEW 3 SANITARY PIPING TO LANDLORD'S SANITARY UNE. VERIFY EXACT LOCATION, SIZE, DEPTH, AND DIRECTION OF FLOW. Q NEW WATTS MODEL #909 (OR EQUAL) RPZ BACK FLOW PREVENTER PROVIDED AND INSTALLED BY PLUMBING CONTRACTOR DOWNSTREAM OF WATER METER. ROUTE RELIEF VALVE PIPING TO MOP SINK, WITH CODE REQUIRED AIR GAP. COORDINATE EXACT LOCATION WITH LANDLORD. PLUMBING PLAN- WATER � WALE 1/4' 1-0 EXTEND AND CONNECT NEW 1 COLD WATER PIPING TO LANDLORD'S EXISTING COLD WATER VERIFY EXACT LOCATION AND SIZE. ADJUST PIPING AS REQUIRED PER ACTUAL LOCATION OF EXTEND AND CONNECT NEW 2" VENT PIPING TO LANDLORD'S EXISTING VENT SYSTEM. FIELD SIZE. 1/2" COLD WATER TO STOP VALVE WITH 3/8" OUTLET, THEN 3/8" COLD WATER TO WATER FILTER, THEN 1/2" FILTER WATER OUT TO STOP VALVE 1/4" OUTLET AND 1/2" OUTLET. ROUTE 1/4" FILTERED WATER PIPING FROM 1/4" FILTER WATER OUTLET TO 1/4" FITTING ON HOT WATER MACHINE. FIELD VERIFY LOCATION. FILTERED WATER STUB SHALL BE AT 48" A.F.F. ROUTE 1/2" FILTERED WATER PIPING FROM 1/2" FILTER WATER OUTLET TO 3/8" FITTING ON ICE MACHINE MACHINE. FIELD VERIFY LOCATION. NEW WALL MOUNTED HAND SINK. PROVIDE 1/2" COLD AND TEMPERED WATER PIPING. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. NEW 3 —COMP. SINK. PROVIDE 1/2" COLD AND 1/2" HOT WATER PIPING. ROUTE INDIRECT WASTE TO FLOOR SINK WITH CODE REQUIRED AIR GAP. FIELD VERIFY SIZE AND LOCATION. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. NEW MOP SINK. PROVIDE 1/2" COLD AND 1/2" HOT WATER PIPING. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. CONTRACTOR SHALL PROVIDE A 5' —O" RUBBER HOSE ACCESSORY FOR MOP SINK. NEW WATER HEATER. PROVIDE 3/4" COLD WATER INLET CONNECTION AND 3/4" HOT WATER OUTLET CONNECTION. ROUTE INDIRECT WASTE BELOW CEILING FROM TEMPERATURE & PRESSURE REDUCING VALVE AND DRAIN PAN TO MOP SINK WITH AIR GAP PER CODE. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. 13 NEW ICE MACHINE. ROUTE INDIRECT WASTE TO FLOOR SINK WITH AIR GAP PER CODE. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. 14 NEW ICE BIN. ROUTE INDIRECT WASTE TO FLOOR SINK WITH CODE REQUIRED AIR GAP. FIELD VERIFY SIZE AND LOCATION. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. © NEW BAR /HAND SINK. PROVIDE 1/2" COLD AND 1/2" TEMPERED WATER PIPING. ROUTE INDIRECT WASTE TO FLOOR SINK WITH CODE REQUIRED AIR GAP. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. PLUMBING KEYED NOTES 0 LINE IN CEILING SPACE BELOW. FIELD COLD WATER PIPING STUB—IN. VERIFY VERIFY EXACT LOCATION AND 1fi 17 18 19 20 21 3/4' •' K 3/4 � 1/2" ) NEW FLOOR SINK (TYPICAL OF 2). REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. NEW THERMOSTATIC MIXING VALVE. INFORMATION. NEW 3" WALL CLEAN OUT. REFER INFORMATION. NEW WATER SUBMETER SUPPLIED AND INSTALLED BY PLUMBING CONTRACTOR. COORDINATE EXACT TYPE AND LOCATION WITH LANDLORD. EXISTING FLOOR CLEAN —OUT. FIELD VERIFY EXACT LOCATION AND SIZE. NEW GREASE INTERCEPTOR RECESSED IN FLOOR. PROVIDE EXTENSIONS AS REQUIRED. SEE KITCHEN FIXTURE PLAN FOR ADDITIONAL INFORMATION. PLUMBING CONTRACTOR'S NOTES ALL OF THE PLUMBING /PIPING WORK IS NOT NECESSARILY SHOWN OR NOTED ON THESE DRAWINGS. THE CONTRACTORS SHALL VISIT THE JOB SITE AND FIELD VERIFY ALL EXISTING CONDITIONS RELATED TO THE WORK PRIOR TO BIDDING. THOSE ITEMS NOT SHOWN OR NOTED BUT WHICH ARE DEEMED NECESSARY FOR REMOVAL OR RELOCATION BY OWNER OR HIS REPRESENTATIVE SHALL BE PART OF HIS CONTRACT. THE SUBMISSION OF THE PROPOSALS SHALL BE CONSIDERED EVIDENCE THAT THE CONTRACTORS HAVE VISITED THE SITE. NO EXTRA PAYMENTS WILL BE ALLOWED THESE CONTRACTORS ON ACCOUNT OF EXTRA WORK MADE NECESSARY BY HIS FAILURE TO VISIT THE JOB SITE. THE PLUMBING CONTRACTOR IS RESPONSIBLE FOR BACK FLOW PREVENTION VALVES AS REQUIRED BY CODE. TEVANA STORES DO NOT HAVE ANY FOOD PREPARATION AND IS NOT CONSIDERED A FOOD OR BEVERAGE SHOP. THE BEVERAGE PREPARATION ACCOUNTS LESS THAN 10% OF THE SALES ON AVERAGE, AND I5 USED PRIMARYILY FOR CUSTOMERS TO FIND WHAT THEY WOULD LIKE FROM TEAVANA'S ASSORTMENT OF OVER 100 LOOSE TEAS. ALL BEVERAGES ARE SREVED IN DISPOSABLE CONTAINERS. 1 1/2" Plar review approval is subject to error. and cmiksiens. 1 1/2" 1 1/2"v Q Approval of construction documerft do- s euthorl the violation of am adopted code or or e,. 's '.-i r ' of approved Feld and ac'o'��: \-.3"V � � s 3/4" WASTE /VENT RISER DIAGRAM SCALE= N.T.S. 3/4" ` • 1/2 - • RE'/ SlONS No rhanries shall be made to th' scr)rA of work without prior approval of Tukwila Building Division. p °CTE: Revisions will require a new p+an subrni -ral and may include additional plan review fees 1 1 /2= .' • 1/2 466.• \�1' �I PLUMBING PLAN - WASTE/VENT C I WATER RISER DIAGRAM SCAB e4' -1-0' REFER TO PLUMBING FIXTURE SCHEDULE FOR ADDITIONAL TO SANITARY RISER DIAGRAM AND DETAIL FOR ADDITIONAL O By L1 1 /2 1 1/2 "V i WCO REVISION 081. ALE COPY Permit No. 2 2 r w co co CI U Q P100 FLOOR i f PENETRATION (TYPICAL) RECEIVED JUN 1 0 7008 TUKWILA PUBLIC WORKS J F�1 r 1 8 City of Tukwila BUILDING DIVISIM F T a;?nIB A JUN 09 2 :ENTFR CE PLUMBING FIXTURE SCHEDULE 0 PLUMBING SYMBOLS FIXTURE DATA CONNECTION DATA DESCRIPTION F.D. T.P.R.V. P.O.C. M.S. LAV. UR. W.C. A.F.F. B�.F.F. I '" I PLAN TAG FIXTURE g MFG. MODEL NO. SOIL SIZE VENT SIZE TRAP INDIRECT WASTE WATER COLD HOT TEMP. FILTER HAND WASH SINK - CI ;` Of Tukwila DROP—IN HAND SINK EUILDAGL R BAR SINK 0 FLOOR SINK 2 ZURN FD- 2377 —NH3 —H 3" 2" 3" - -- - -- - -- - -- 1/2 GRATE ® BACKFLDW PR 1 WAS GENERAL CONTRACTOR _ —_ TO FLOOR DRAIN 1.. _,• -- --- - -- RPZ BACKFLOW PREVENTER FOR MAIN SERVICE. ICE MACHINE 1 MANITOWOC S— SERIES 322 - -- ---- — 2 1/2" 1 3/4 TO F.S. - -- - -- -- " 3/8. MANITOWOC STORAGE BIN B -320, 1/2" INDIRECT TO F.S. O 3— COMPARTMENT SINK 1 EAGLE GROUP 414- 16 -3 -18 - -- - -- - -- TO FLOOR SINK 1/2" 1/2" --- W /DOUBLE DRAIN BOARD EAGLE GROUP SPRAYER 300719. 0 MOP SINK 1 UNIVERSAL STAINLESS MOP -20 -8 2" 2" 2" 1/2" 1/2" - -- - -- UNIVERSAL STAINLESS SERVICE FAUCET SF -8, HOSE END WITH 5' -0" HOSE, VACUUM BREAKER, AND UNIVERSAL STAINLESS MOP HANGER MH -3. ® THERMOSTATIC �/ MIXING VALVE 1 SYMMONS 5-130 —_— ___ —_- 3 / 4 " IN 3/4" IN 3/4" OUT ___ PROVIDE UNIONS AND HAMMOND #8501H FULL PORT BALL VALVE. / �'J TED WALL ND MATTED HA 1 ELKAY CHS1716C 1-1/2" / 1-1/2" / 1 -1/2" 1/2" - -- 1/2" - -- ELKAY FAUCET LK499 (INCLUDED WITH SINK) BAR SINK 1 ADVANCE DI -1 -25 - -- - -- - -- TO F.S. 1/2" 1/2" -- BAR SINKS CERTIFIED. ® HOT WATER MACHINE 1 BUNN H1OX - -- - -- - -- - -- - -- - -- 1/4" 10 WATER HEATER 1 RHEEM EGSP20 - -- --'— — __ 3/4" T &P TO M.S. 3/4" IN 3/4" OUT —__ - -- 19.9 — GA TEMPERATURE 40'F IN AND 140'F OUT 6 .000 WA TTS, 208V 1 PH, 98% EFFICIENCY RATING. 11 WALL CLEANOUT 1 *J.R. SMFFH 3" - -- - -- - -- - -- - -- - -- 12 WATER FILTER 1 MANITOWOC AR20000 - -- - -- - -- 1/2" IN _,_•— ___ 1/2" OUT PROVIDED BY OWNER, INSTALLED BY CONTRACTOR. @ NOT USED O. ICE BIN 1 MOLT INTERNATIONAL BIB-1418 - -- _ -- 1 -1/2" TO F.S. __— _ —_ —__ - -- 15 FLOOR CLEANOUT 1 *J.R. SMITH q" _ _ _ -- -- -- --- _ -- _ --- 16 DROP -IN HA NDSINK 1 ADVANCE TABCO DI -1 -5 ___ - --. ----_ 1-1/2" TO F.S. 1/2" --- 1/2" --- W /K -62 ADVANCE TABCO FAUCET SINK IS NSF CERTIFIED. INTERIOR IOR GREASE 1 *ZURN GT2700 -25 3 - -- - -- - -- - -- - -- - -- PROVIDED AND INSTALLED BY CONTRACTOR 21 FLOOR DRAIN 1 ZURN Z504- 3 —ZN —Y 3" 2" 3" - -- —•---- - -- © NEW 25 GPM VENTED FLOW CONTROL VALVE PROVIDED AND INSTALLED BY CONTRACTOR r * OR GENERAL NOTES: 1. REFER TO SHEET FIXTURE PLAN FOR FAUCETS, FURNISHING AND INSTALLATION RESPONSIBILITIES. 2. INSTALL FIXTURES, FITTINGS, AND ACCESSORIES PER MANUFACTURER'S INSTRUCTIONS. 3. INSTALL EACH FIXTURE WITH TRAP, LOOSE KEY STOPS, FLEXIBLE SUPPUES, REDUCERS, AND ESCUTCHEONS. APPROVED EQUAL PLUNGING GENERAL NOTES ALL PLUMBING WORK TO COMPLY WITH ALL APPLICABLE CODES AND LANDLORD CRITERIA. ALL HOT AND COLD PIPING AND FITTINGS SHALL BE INSULATED WITH 1/2" THICK SNAP ON FIBERGLASS INSULATION WITH CANVAS JACKET COVER COLD WATER PIPING INSULATION SHALL INCLUDE VAPOR BARRIER JACKET SEALED WITH CEMENT. STERILIZATION OF DOMESTIC WATER SYSTEM. BEFORE BEING PLACED IN SERVICE ALL WATER LINES SHALL BE CHLORINATED TO THE SATISFACTION OF THE ENGINEER IN ACCORDANCE WITH AWWA SPEC C60 -53T. PROVIDE ACCESSIBLE SHUT —OFF VALVES AT ALL PLUMBING FIXTURES. WATER VALVES TO BE JENKINS #476 OR EQUAL. INSTALL SHOCK ABSORBERS ON ALL HOT AND COLD WATER BRANCH LINES TO PLUMBING FIXTURES AND EQUIPMENT. SANITARY AND VENT PIPING SHALL BE SERVICE WEIGHT CAST IRON NO —HUB WITH CAST IRON FITTINGS WITH STAINLESS STEEL NO —HUB COUPLINGS NEOPRENE GASKET. NO PVC PIPING IS PERMITTED. SOLDER JOINT FITTINGS USING 95 -5 LEAD FREE SOLDER. WATER PIPING ABOVE GRADE SHALL CONSIST OF TYPE "L" HARD COPPER TUBING WITH WROUGHT COPPER FITTINGS USING SILVER SOLDER. INSTALL WATER METER AS REQUIRED BY APPLICABLE CODES, UTILITY COMPANY, AND LANDLORD REQUIREMENTS. ESCUTCHEONS: PROVIDE EXPOSED PIPING, BOTH BARE AND COVERED WITH CP CAST BRASS ESCUTCHEONS WHERE PASSING THROUGH FLOORS, CEILINGS, WALLS OR PARTITIONS. SUPPORT HORIZONTAL DRAINAGE PIPING AT LEAST EVERY 5' —O" OR AT EVERY HUB, COPPER TUBING EVERY 7' -0" AND STEEL PIPE EVERY 10' -0" WITH CLEVIS HANGER AND INSULATION PROTECTION SHIELDS. PIPING SHALL NOT BE SUPPORTED FROM BRIDGING OR OTHER PIPING. TEST PIPING AND PROVE TIGHT FOR AT LEAST TWO HOURS IN ACCORDANCE WITH REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION AND OR AS SPECIFIED, TEST SHALL BE PERFORMED IN THE PRESENCE OF THE TENANT REPRESENTATIVE AND LOCAL INSPECTOR TEST SHALL BE REPEATED IF NECESSARY UNTIL FINAL APPROVAL OF SYSTEM IS OBTAINED. TEST DRAINAGE AND VENT PIPING BY FILLING WITH WATER TO OVERFLOWING. WATER LEVEL TO REMAIN CONSTANT. TEST WATER PIPING WITH WATER 13 TIMES THE WORKING PRESSURE. ALL SANITARY SEWER LINES TO BE SLOPED AT MINIMUM 1/4" PER FOOT. ALL PLUMBING FLOOR PENETRATIONS MUST HAVE "LINK SEALS" INSTALLED BEFORE MEMBRANE IS INSTALLED. EXPOSED HORIZONTAL WATER PIPING SHALL BE INSTALLED IN ACCORDANCE WITH LOCAL HEALTH DEPT. CODE. PROVIDE WATER METER, REMOTE REGISTER READ IN CUBIC FEET, EASILY ACCESSIBLE TO MALL PERSONNEL LOCATE IN BATHROOM OR STOCK ROOM. INTERIOR GREASE TRAP SIZING DIMENSIONS OF EACH BOWL OF 3— COMPARTMENT SINK TOTAL CAPACITY OF 3—COMPARTMENT SINK (TOTAL OF 3 BOWLS) CAPACITY IN GALLONS (DIVIDE BY 231) ACTUAL DRAINAGE LOAD (75% OF TOTAL CAPACITY) FLOW RATE FOR 1 MINUTE FLOW RATE FOR 2 MINUTE 16 "x 19 "x 13.5" 16" x 19" x 13.5" 16" x 19" x 13.5" 12,312 CUBIC INCHES 53.3 GAL 40 GAL 40 GPM OR 80 LBS. 20 GPM OR 40 LBS. (2 LB. RETENTION = 1 GPM /FLOW) *ZURN GREASE INTERCEPTOR MODEL GT2700 -25 HANDLES 25 GPM AND PROVIDES 50 LBS. OF CAPACITY. LANDLORD NOTES ALL TENANTS ON THE GROUND FLOOR REQUIRING BELOW GRADE WORK SHALL COORDINATE WITH LANDLORD PRIOR TO ANY SLAB DEMOLITION. TENANT SHALL COORDINATE WITH LANDLORD TO PROVIDE OPPORTUNITY FOR SPECIAL INSPECTION AND PHOTOGRAPHIC DOCUMENTATION BY LANDLORD. OF BELOW GRADE WORK PRIOR TO THE COVERING UP OF SUCH WORK. TENANT SHALL BE RESPONSIBLE FOR RECONSTRUCTION AND PATCHING OF THE SLAB —ON —GRADE SYSTEM, INCLUDING GRAVEL LAYERS, VAPOR BARRIER, AND CONCRETE. 2. ALL FOOD SERVICE AND EXCESSIVE WATER USE TENANTS SHALL BE REQUIRED TO INSTALL A COLD WATER SUBMETER ASSEMBLY (REGISTERING IN GALLONS) WITH PRESSURE REGULATOR, GROUND JUMPER WIRE AND ALL FURTHER INSTALLATIONS AND CONNECTIONS, IN ACCORDANCE WITH ALL GIVEN REQUIREMENTS AT THE REAR PORTION OF THE TENANT SPACE IN A READILY ACCESSIBLE LOCATION, AT A MAXIMUM (48 ") ABOVE THE FINISHED FLOOR. 3 LANDLORD PROVIDED A CAPPED SANITARY VENT CONNECTION LOCATED WITHIN OR ADJACENT TO THE TENANT SPACE IN THE CEILING, VERIFY EXACT LOCATION IN FIELD. TENANT IS RESPONSIBLE TO EXTEND FROM THEIR SPACE TO POINT OF CONNECTION AT TENANT'S EXPENSE. 4. TENANT'S CONTRACTOR SHALL VERIFY POINTS OF CONNECTION FOR ALL VENT, SEWER, AND WATER PIPING WITH MALL MANAGEMENT BEFORE PROCEEDING WITH WORK. TENANT I5 RESPONSIBLE FOR EXTENDING PIPING FROM POINT OF EXISTING CONNECTIONS TO TENANT SPACE AT TENANT'S EXPENSE. 5. TENANT TO SUBMIT FOR CODE VARIANCE REGARDING GREASE TRAP INSTALLATION REQUIREMENTS. 0 WATER FILTER FOR ICE MACHINE AND HOT WATER MACHINE. LOCATE IN STOCK AREA IN EASILY ACCESSIBLE LOCATION. O EXTEND AND CONNECT NEW 3 SANITARY PIPING TO LANDLORD'S SANITARY UNE. VERIFY EXACT LOCATION, SIZE, DEPTH, AND DIRECTION OF FLOW. Q NEW WATTS MODEL #909 (OR EQUAL) RPZ BACK FLOW PREVENTER PROVIDED AND INSTALLED BY PLUMBING CONTRACTOR DOWNSTREAM OF WATER METER. ROUTE RELIEF VALVE PIPING TO MOP SINK, WITH CODE REQUIRED AIR GAP. COORDINATE EXACT LOCATION WITH LANDLORD. PLUMBING PLAN- WATER � WALE 1/4' 1-0 EXTEND AND CONNECT NEW 1 COLD WATER PIPING TO LANDLORD'S EXISTING COLD WATER VERIFY EXACT LOCATION AND SIZE. ADJUST PIPING AS REQUIRED PER ACTUAL LOCATION OF EXTEND AND CONNECT NEW 2" VENT PIPING TO LANDLORD'S EXISTING VENT SYSTEM. FIELD SIZE. 1/2" COLD WATER TO STOP VALVE WITH 3/8" OUTLET, THEN 3/8" COLD WATER TO WATER FILTER, THEN 1/2" FILTER WATER OUT TO STOP VALVE 1/4" OUTLET AND 1/2" OUTLET. ROUTE 1/4" FILTERED WATER PIPING FROM 1/4" FILTER WATER OUTLET TO 1/4" FITTING ON HOT WATER MACHINE. FIELD VERIFY LOCATION. FILTERED WATER STUB SHALL BE AT 48" A.F.F. ROUTE 1/2" FILTERED WATER PIPING FROM 1/2" FILTER WATER OUTLET TO 3/8" FITTING ON ICE MACHINE MACHINE. FIELD VERIFY LOCATION. NEW WALL MOUNTED HAND SINK. PROVIDE 1/2" COLD AND TEMPERED WATER PIPING. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. NEW 3 —COMP. SINK. PROVIDE 1/2" COLD AND 1/2" HOT WATER PIPING. ROUTE INDIRECT WASTE TO FLOOR SINK WITH CODE REQUIRED AIR GAP. FIELD VERIFY SIZE AND LOCATION. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. NEW MOP SINK. PROVIDE 1/2" COLD AND 1/2" HOT WATER PIPING. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. CONTRACTOR SHALL PROVIDE A 5' —O" RUBBER HOSE ACCESSORY FOR MOP SINK. NEW WATER HEATER. PROVIDE 3/4" COLD WATER INLET CONNECTION AND 3/4" HOT WATER OUTLET CONNECTION. ROUTE INDIRECT WASTE BELOW CEILING FROM TEMPERATURE & PRESSURE REDUCING VALVE AND DRAIN PAN TO MOP SINK WITH AIR GAP PER CODE. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. 13 NEW ICE MACHINE. ROUTE INDIRECT WASTE TO FLOOR SINK WITH AIR GAP PER CODE. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. 14 NEW ICE BIN. ROUTE INDIRECT WASTE TO FLOOR SINK WITH CODE REQUIRED AIR GAP. FIELD VERIFY SIZE AND LOCATION. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. © NEW BAR /HAND SINK. PROVIDE 1/2" COLD AND 1/2" TEMPERED WATER PIPING. ROUTE INDIRECT WASTE TO FLOOR SINK WITH CODE REQUIRED AIR GAP. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. PLUMBING KEYED NOTES 0 LINE IN CEILING SPACE BELOW. FIELD COLD WATER PIPING STUB—IN. VERIFY VERIFY EXACT LOCATION AND 1fi 17 18 19 20 21 3/4' •' K 3/4 � 1/2" ) NEW FLOOR SINK (TYPICAL OF 2). REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. NEW THERMOSTATIC MIXING VALVE. INFORMATION. NEW 3" WALL CLEAN OUT. REFER INFORMATION. NEW WATER SUBMETER SUPPLIED AND INSTALLED BY PLUMBING CONTRACTOR. COORDINATE EXACT TYPE AND LOCATION WITH LANDLORD. EXISTING FLOOR CLEAN —OUT. FIELD VERIFY EXACT LOCATION AND SIZE. NEW GREASE INTERCEPTOR RECESSED IN FLOOR. PROVIDE EXTENSIONS AS REQUIRED. SEE KITCHEN FIXTURE PLAN FOR ADDITIONAL INFORMATION. PLUMBING CONTRACTOR'S NOTES ALL OF THE PLUMBING /PIPING WORK IS NOT NECESSARILY SHOWN OR NOTED ON THESE DRAWINGS. THE CONTRACTORS SHALL VISIT THE JOB SITE AND FIELD VERIFY ALL EXISTING CONDITIONS RELATED TO THE WORK PRIOR TO BIDDING. THOSE ITEMS NOT SHOWN OR NOTED BUT WHICH ARE DEEMED NECESSARY FOR REMOVAL OR RELOCATION BY OWNER OR HIS REPRESENTATIVE SHALL BE PART OF HIS CONTRACT. THE SUBMISSION OF THE PROPOSALS SHALL BE CONSIDERED EVIDENCE THAT THE CONTRACTORS HAVE VISITED THE SITE. NO EXTRA PAYMENTS WILL BE ALLOWED THESE CONTRACTORS ON ACCOUNT OF EXTRA WORK MADE NECESSARY BY HIS FAILURE TO VISIT THE JOB SITE. THE PLUMBING CONTRACTOR IS RESPONSIBLE FOR BACK FLOW PREVENTION VALVES AS REQUIRED BY CODE. TEVANA STORES DO NOT HAVE ANY FOOD PREPARATION AND IS NOT CONSIDERED A FOOD OR BEVERAGE SHOP. THE BEVERAGE PREPARATION ACCOUNTS LESS THAN 10% OF THE SALES ON AVERAGE, AND I5 USED PRIMARYILY FOR CUSTOMERS TO FIND WHAT THEY WOULD LIKE FROM TEAVANA'S ASSORTMENT OF OVER 100 LOOSE TEAS. ALL BEVERAGES ARE SREVED IN DISPOSABLE CONTAINERS. 1 1/2" Plar review approval is subject to error. and cmiksiens. 1 1/2" 1 1/2"v Q Approval of construction documerft do- s euthorl the violation of am adopted code or or e,. 's '.-i r ' of approved Feld and ac'o'��: \-.3"V � � s 3/4" WASTE /VENT RISER DIAGRAM SCALE= N.T.S. 3/4" ` • 1/2 - • RE'/ SlONS No rhanries shall be made to th' scr)rA of work without prior approval of Tukwila Building Division. p °CTE: Revisions will require a new p+an subrni -ral and may include additional plan review fees 1 1 /2= .' • 1/2 466.• \�1' �I PLUMBING PLAN - WASTE/VENT C I WATER RISER DIAGRAM SCAB e4' -1-0' REFER TO PLUMBING FIXTURE SCHEDULE FOR ADDITIONAL TO SANITARY RISER DIAGRAM AND DETAIL FOR ADDITIONAL O By L1 1 /2 1 1/2 "V i WCO REVISION 081. ALE COPY Permit No. 2 2 r w co co CI U Q P100 FLOOR i f PENETRATION (TYPICAL) RECEIVED JUN 1 0 7008 TUKWILA PUBLIC WORKS J F�1 r 1 8 City of Tukwila BUILDING DIVISIM F T a;?nIB A JUN 09 2 :ENTFR CE PLUMBING SYMBOLS SAN. SANITARY SEWER LINE GREASE WASTE LINE VENT UNE GAS LINE COLD WATER LINE HOT WATER UNE TEMPERED WATER LINE FILTERED WATER LINE SHUT —OFF VALVE BACKFLOW PREVENTER VENT THRU ROOF CAST IRON COLD WATER HOT WATER TEMPERED WATER FILTER WATER FLOOR SINK F.D. T.P.R.V. P.O.C. M.S. LAV. UR. W.C. A.F.F. B�.F.F. I '" I FLOOR DRAIN TEMPERATURE PRESSURE RELIEF VALVE POINT OF CONNECTION MOP SINK LAVATORY URINAL WATER CLOSET N K VI W 1) FO ABOVE FINISHED FLOQTEDDE COMPLIA BELOW FINISHED FLOOR WATER METER I ' . PPS VE WATER HEATER ' FLOOR CLEAN OUT JUN 2 ( 2098 WALL CLEAN OUT A • HAND SINK . ' Cil — GW V _ — — — — — . - - • — — — _ — . - — - - — - . — - [74 N V.T.R. C.I. C.W. H.W. T.W. F.W. F.S. W.H. F.C.O. W.C.O. H.S. H.W.S. D.H.S. B.S. HAND WASH SINK - CI ;` Of Tukwila DROP—IN HAND SINK EUILDAGL R BAR SINK PLUNGING GENERAL NOTES ALL PLUMBING WORK TO COMPLY WITH ALL APPLICABLE CODES AND LANDLORD CRITERIA. ALL HOT AND COLD PIPING AND FITTINGS SHALL BE INSULATED WITH 1/2" THICK SNAP ON FIBERGLASS INSULATION WITH CANVAS JACKET COVER COLD WATER PIPING INSULATION SHALL INCLUDE VAPOR BARRIER JACKET SEALED WITH CEMENT. STERILIZATION OF DOMESTIC WATER SYSTEM. BEFORE BEING PLACED IN SERVICE ALL WATER LINES SHALL BE CHLORINATED TO THE SATISFACTION OF THE ENGINEER IN ACCORDANCE WITH AWWA SPEC C60 -53T. PROVIDE ACCESSIBLE SHUT —OFF VALVES AT ALL PLUMBING FIXTURES. WATER VALVES TO BE JENKINS #476 OR EQUAL. INSTALL SHOCK ABSORBERS ON ALL HOT AND COLD WATER BRANCH LINES TO PLUMBING FIXTURES AND EQUIPMENT. SANITARY AND VENT PIPING SHALL BE SERVICE WEIGHT CAST IRON NO —HUB WITH CAST IRON FITTINGS WITH STAINLESS STEEL NO —HUB COUPLINGS NEOPRENE GASKET. NO PVC PIPING IS PERMITTED. SOLDER JOINT FITTINGS USING 95 -5 LEAD FREE SOLDER. WATER PIPING ABOVE GRADE SHALL CONSIST OF TYPE "L" HARD COPPER TUBING WITH WROUGHT COPPER FITTINGS USING SILVER SOLDER. INSTALL WATER METER AS REQUIRED BY APPLICABLE CODES, UTILITY COMPANY, AND LANDLORD REQUIREMENTS. ESCUTCHEONS: PROVIDE EXPOSED PIPING, BOTH BARE AND COVERED WITH CP CAST BRASS ESCUTCHEONS WHERE PASSING THROUGH FLOORS, CEILINGS, WALLS OR PARTITIONS. SUPPORT HORIZONTAL DRAINAGE PIPING AT LEAST EVERY 5' —O" OR AT EVERY HUB, COPPER TUBING EVERY 7' -0" AND STEEL PIPE EVERY 10' -0" WITH CLEVIS HANGER AND INSULATION PROTECTION SHIELDS. PIPING SHALL NOT BE SUPPORTED FROM BRIDGING OR OTHER PIPING. TEST PIPING AND PROVE TIGHT FOR AT LEAST TWO HOURS IN ACCORDANCE WITH REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION AND OR AS SPECIFIED, TEST SHALL BE PERFORMED IN THE PRESENCE OF THE TENANT REPRESENTATIVE AND LOCAL INSPECTOR TEST SHALL BE REPEATED IF NECESSARY UNTIL FINAL APPROVAL OF SYSTEM IS OBTAINED. TEST DRAINAGE AND VENT PIPING BY FILLING WITH WATER TO OVERFLOWING. WATER LEVEL TO REMAIN CONSTANT. TEST WATER PIPING WITH WATER 13 TIMES THE WORKING PRESSURE. ALL SANITARY SEWER LINES TO BE SLOPED AT MINIMUM 1/4" PER FOOT. ALL PLUMBING FLOOR PENETRATIONS MUST HAVE "LINK SEALS" INSTALLED BEFORE MEMBRANE IS INSTALLED. EXPOSED HORIZONTAL WATER PIPING SHALL BE INSTALLED IN ACCORDANCE WITH LOCAL HEALTH DEPT. CODE. PROVIDE WATER METER, REMOTE REGISTER READ IN CUBIC FEET, EASILY ACCESSIBLE TO MALL PERSONNEL LOCATE IN BATHROOM OR STOCK ROOM. INTERIOR GREASE TRAP SIZING DIMENSIONS OF EACH BOWL OF 3— COMPARTMENT SINK TOTAL CAPACITY OF 3—COMPARTMENT SINK (TOTAL OF 3 BOWLS) CAPACITY IN GALLONS (DIVIDE BY 231) ACTUAL DRAINAGE LOAD (75% OF TOTAL CAPACITY) FLOW RATE FOR 1 MINUTE FLOW RATE FOR 2 MINUTE 16 "x 19 "x 13.5" 16" x 19" x 13.5" 16" x 19" x 13.5" 12,312 CUBIC INCHES 53.3 GAL 40 GAL 40 GPM OR 80 LBS. 20 GPM OR 40 LBS. (2 LB. RETENTION = 1 GPM /FLOW) *ZURN GREASE INTERCEPTOR MODEL GT2700 -25 HANDLES 25 GPM AND PROVIDES 50 LBS. OF CAPACITY. LANDLORD NOTES ALL TENANTS ON THE GROUND FLOOR REQUIRING BELOW GRADE WORK SHALL COORDINATE WITH LANDLORD PRIOR TO ANY SLAB DEMOLITION. TENANT SHALL COORDINATE WITH LANDLORD TO PROVIDE OPPORTUNITY FOR SPECIAL INSPECTION AND PHOTOGRAPHIC DOCUMENTATION BY LANDLORD. OF BELOW GRADE WORK PRIOR TO THE COVERING UP OF SUCH WORK. TENANT SHALL BE RESPONSIBLE FOR RECONSTRUCTION AND PATCHING OF THE SLAB —ON —GRADE SYSTEM, INCLUDING GRAVEL LAYERS, VAPOR BARRIER, AND CONCRETE. 2. ALL FOOD SERVICE AND EXCESSIVE WATER USE TENANTS SHALL BE REQUIRED TO INSTALL A COLD WATER SUBMETER ASSEMBLY (REGISTERING IN GALLONS) WITH PRESSURE REGULATOR, GROUND JUMPER WIRE AND ALL FURTHER INSTALLATIONS AND CONNECTIONS, IN ACCORDANCE WITH ALL GIVEN REQUIREMENTS AT THE REAR PORTION OF THE TENANT SPACE IN A READILY ACCESSIBLE LOCATION, AT A MAXIMUM (48 ") ABOVE THE FINISHED FLOOR. 3 LANDLORD PROVIDED A CAPPED SANITARY VENT CONNECTION LOCATED WITHIN OR ADJACENT TO THE TENANT SPACE IN THE CEILING, VERIFY EXACT LOCATION IN FIELD. TENANT IS RESPONSIBLE TO EXTEND FROM THEIR SPACE TO POINT OF CONNECTION AT TENANT'S EXPENSE. 4. TENANT'S CONTRACTOR SHALL VERIFY POINTS OF CONNECTION FOR ALL VENT, SEWER, AND WATER PIPING WITH MALL MANAGEMENT BEFORE PROCEEDING WITH WORK. TENANT I5 RESPONSIBLE FOR EXTENDING PIPING FROM POINT OF EXISTING CONNECTIONS TO TENANT SPACE AT TENANT'S EXPENSE. 5. TENANT TO SUBMIT FOR CODE VARIANCE REGARDING GREASE TRAP INSTALLATION REQUIREMENTS. 0 WATER FILTER FOR ICE MACHINE AND HOT WATER MACHINE. LOCATE IN STOCK AREA IN EASILY ACCESSIBLE LOCATION. O EXTEND AND CONNECT NEW 3 SANITARY PIPING TO LANDLORD'S SANITARY UNE. VERIFY EXACT LOCATION, SIZE, DEPTH, AND DIRECTION OF FLOW. Q NEW WATTS MODEL #909 (OR EQUAL) RPZ BACK FLOW PREVENTER PROVIDED AND INSTALLED BY PLUMBING CONTRACTOR DOWNSTREAM OF WATER METER. ROUTE RELIEF VALVE PIPING TO MOP SINK, WITH CODE REQUIRED AIR GAP. COORDINATE EXACT LOCATION WITH LANDLORD. PLUMBING PLAN- WATER � WALE 1/4' 1-0 EXTEND AND CONNECT NEW 1 COLD WATER PIPING TO LANDLORD'S EXISTING COLD WATER VERIFY EXACT LOCATION AND SIZE. ADJUST PIPING AS REQUIRED PER ACTUAL LOCATION OF EXTEND AND CONNECT NEW 2" VENT PIPING TO LANDLORD'S EXISTING VENT SYSTEM. FIELD SIZE. 1/2" COLD WATER TO STOP VALVE WITH 3/8" OUTLET, THEN 3/8" COLD WATER TO WATER FILTER, THEN 1/2" FILTER WATER OUT TO STOP VALVE 1/4" OUTLET AND 1/2" OUTLET. ROUTE 1/4" FILTERED WATER PIPING FROM 1/4" FILTER WATER OUTLET TO 1/4" FITTING ON HOT WATER MACHINE. FIELD VERIFY LOCATION. FILTERED WATER STUB SHALL BE AT 48" A.F.F. ROUTE 1/2" FILTERED WATER PIPING FROM 1/2" FILTER WATER OUTLET TO 3/8" FITTING ON ICE MACHINE MACHINE. FIELD VERIFY LOCATION. NEW WALL MOUNTED HAND SINK. PROVIDE 1/2" COLD AND TEMPERED WATER PIPING. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. NEW 3 —COMP. SINK. PROVIDE 1/2" COLD AND 1/2" HOT WATER PIPING. ROUTE INDIRECT WASTE TO FLOOR SINK WITH CODE REQUIRED AIR GAP. FIELD VERIFY SIZE AND LOCATION. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. NEW MOP SINK. PROVIDE 1/2" COLD AND 1/2" HOT WATER PIPING. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. CONTRACTOR SHALL PROVIDE A 5' —O" RUBBER HOSE ACCESSORY FOR MOP SINK. NEW WATER HEATER. PROVIDE 3/4" COLD WATER INLET CONNECTION AND 3/4" HOT WATER OUTLET CONNECTION. ROUTE INDIRECT WASTE BELOW CEILING FROM TEMPERATURE & PRESSURE REDUCING VALVE AND DRAIN PAN TO MOP SINK WITH AIR GAP PER CODE. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. 13 NEW ICE MACHINE. ROUTE INDIRECT WASTE TO FLOOR SINK WITH AIR GAP PER CODE. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. 14 NEW ICE BIN. ROUTE INDIRECT WASTE TO FLOOR SINK WITH CODE REQUIRED AIR GAP. FIELD VERIFY SIZE AND LOCATION. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. © NEW BAR /HAND SINK. PROVIDE 1/2" COLD AND 1/2" TEMPERED WATER PIPING. ROUTE INDIRECT WASTE TO FLOOR SINK WITH CODE REQUIRED AIR GAP. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. PLUMBING KEYED NOTES 0 LINE IN CEILING SPACE BELOW. FIELD COLD WATER PIPING STUB—IN. VERIFY VERIFY EXACT LOCATION AND 1fi 17 18 19 20 21 3/4' •' K 3/4 � 1/2" ) NEW FLOOR SINK (TYPICAL OF 2). REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. NEW THERMOSTATIC MIXING VALVE. INFORMATION. NEW 3" WALL CLEAN OUT. REFER INFORMATION. NEW WATER SUBMETER SUPPLIED AND INSTALLED BY PLUMBING CONTRACTOR. COORDINATE EXACT TYPE AND LOCATION WITH LANDLORD. EXISTING FLOOR CLEAN —OUT. FIELD VERIFY EXACT LOCATION AND SIZE. NEW GREASE INTERCEPTOR RECESSED IN FLOOR. PROVIDE EXTENSIONS AS REQUIRED. SEE KITCHEN FIXTURE PLAN FOR ADDITIONAL INFORMATION. PLUMBING CONTRACTOR'S NOTES ALL OF THE PLUMBING /PIPING WORK IS NOT NECESSARILY SHOWN OR NOTED ON THESE DRAWINGS. THE CONTRACTORS SHALL VISIT THE JOB SITE AND FIELD VERIFY ALL EXISTING CONDITIONS RELATED TO THE WORK PRIOR TO BIDDING. THOSE ITEMS NOT SHOWN OR NOTED BUT WHICH ARE DEEMED NECESSARY FOR REMOVAL OR RELOCATION BY OWNER OR HIS REPRESENTATIVE SHALL BE PART OF HIS CONTRACT. THE SUBMISSION OF THE PROPOSALS SHALL BE CONSIDERED EVIDENCE THAT THE CONTRACTORS HAVE VISITED THE SITE. NO EXTRA PAYMENTS WILL BE ALLOWED THESE CONTRACTORS ON ACCOUNT OF EXTRA WORK MADE NECESSARY BY HIS FAILURE TO VISIT THE JOB SITE. THE PLUMBING CONTRACTOR IS RESPONSIBLE FOR BACK FLOW PREVENTION VALVES AS REQUIRED BY CODE. TEVANA STORES DO NOT HAVE ANY FOOD PREPARATION AND IS NOT CONSIDERED A FOOD OR BEVERAGE SHOP. THE BEVERAGE PREPARATION ACCOUNTS LESS THAN 10% OF THE SALES ON AVERAGE, AND I5 USED PRIMARYILY FOR CUSTOMERS TO FIND WHAT THEY WOULD LIKE FROM TEAVANA'S ASSORTMENT OF OVER 100 LOOSE TEAS. ALL BEVERAGES ARE SREVED IN DISPOSABLE CONTAINERS. 1 1/2" Plar review approval is subject to error. and cmiksiens. 1 1/2" 1 1/2"v Q Approval of construction documerft do- s euthorl the violation of am adopted code or or e,. 's '.-i r ' of approved Feld and ac'o'��: \-.3"V � � s 3/4" WASTE /VENT RISER DIAGRAM SCALE= N.T.S. 3/4" ` • 1/2 - • RE'/ SlONS No rhanries shall be made to th' scr)rA of work without prior approval of Tukwila Building Division. p °CTE: Revisions will require a new p+an subrni -ral and may include additional plan review fees 1 1 /2= .' • 1/2 466.• \�1' �I PLUMBING PLAN - WASTE/VENT C I WATER RISER DIAGRAM SCAB e4' -1-0' REFER TO PLUMBING FIXTURE SCHEDULE FOR ADDITIONAL TO SANITARY RISER DIAGRAM AND DETAIL FOR ADDITIONAL O By L1 1 /2 1 1/2 "V i WCO REVISION 081. ALE COPY Permit No. 2 2 r w co co CI U Q P100 FLOOR i f PENETRATION (TYPICAL) RECEIVED JUN 1 0 7008 TUKWILA PUBLIC WORKS J F�1 r 1 8 City of Tukwila BUILDING DIVISIM F T a;?nIB A JUN 09 2 :ENTFR CE PLUMBING GENERAL NOTES ALL PLUMBING WORK TO COMPLY WITH ALL APPLICABLE CODES AND LANDLORD CRITERIA. ALL HOT AND COLD PIPING AND FITTINGS SHALL BE INSULATED WITH 1/2" THICK SNAP ON FIBERGLASS INSULATION WITH CANVAS JACKET COVER COLD WATER PIPING INSULATION SHALL INCLUDE VAPOR BARRIER JACKET SEALED WITH CEMENT. STERILIZATION OF DOMESTIC WATER SYSTEM. BEFORE BEING PLACED IN SERVICE ALL WATER LINES SHALL BE CHLORINATED TO THE SATISFACTION OF THE ENGINEER IN ACCORDANCE WITH AWWA SPEC C60 -53T. PROVIDE ACCESSIBLE SHUT -OFF VALVES AT ALL PLUMBING FIXTURES. WATER VALVES TO BE JENKINS #476 OR EQUAL. INSTALL SHOCK ABSORBERS ON ALL HOT AND COLD WATER BRANCH LINES TO PLUMBING FIXTURES AND EQUIPMENT. SANITARY AND VENT PIPING SHALL BE SERVICE WEIGHT CAST IRON NO -HUB WITH CAST IRON FITTINGS WITH STAINLESS STEEL NO -HUB COUPLINGS NEOPRENE GASKET. NO PVC PIPING IS PERMITTED. SOLDER JOINT FITTINGS USING 95 -5 LEAD FREE SOLDER. WATER PIPING ABOVE GRADE SHALL CONSIST OF TYPE "L" HARD COPPER TUBING WITH WROUGHT COPPER FITTINGS USING SILVER SOLDER. INSTALL WATER METER AS REQUIRED BY APPLICABLE CODES, UTILITY COMPANY, AND LANDLORD REQUIREMENTS. ESCUTCHEONS: PROVIDE EXPOSED PIPING, BOTH BARE AND COVERED WITH CP CAST BRASS ESCUTCHEONS WHERE PASSING THROUGH FLOORS, CEILINGS, WALLS OR PARTITIONS. SUPPORT HORIZONTAL DRAINAGE PIPING AT LEAST EVERY 5' -0" OR AT EVERY HUB, COPPER TUBING EVERY 7' -0" AND STEEL PIPE EVERY 10' -0" WITH CLEVIS HANGER AND INSULATION PROTECTION SHIELDS. PIPING SHALL NOT BE SUPPORTED FROM BRIDGING OR OTHER PIPING. TEST PIPING AND PROVE TIGHT FOR AT LEAST TWO HOURS IN ACCORDANCE WITH REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION AND OR AS SPECIFIED, TEST SHALL BE PERFORMED IN THE PRESENCE OF THE TENANT REPRESENTATIVE AND LOCAL INSPECTOR TEST SHALL BE REPEATED IF NECESSARY UNTIL FINAL APPROVAL OF SYSTEM IS OBTAINED. TEST DRAINAGE AND VENT PIPING BY FILLING WITH WATER TO OVERFLOWING. WATER LEVEL TO REMAIN CONSTANT. TEST WATER PIPING WITH WATER 13 TIMES THE WORKING PRESSURE. ALL SANITARY SEWER LINES TO BE SLOPED AT MINIMUM 1/4" PER FOOT. ALL PLUMBING FLOOR PENETRATIONS MUST HAVE "LINK SEALS" INSTALLED BEFORE MEMBRANE IS INSTALLED EXPOSED HORIZONTAL WATER PIPING SHALL BE INSTALLED IN ACCORDANCE WITH LOCAL HEALTH DEPT. CODE. PROVIDE WATER METER, REMOTE REGISTER READ IN CUBIC FEET, EASILY ACCESSIBLE TO MALL PERSONNEL. LOCATE IN BATHROOM OR STOCK ROOM. INTERIOR GREASE TRAP SIZING DIMENSIONS OF EACH BOWL OF 3- COMPARTMENT SINK TOTAL CAPACITY OF 3- COMPARTMENT SINK (TOTAL OF 3 BOWLS) CAPACITY IN GALLONS 53.3 GAL (DIVIDE BY 231) ACTUAL DRAINAGE LOAD (75% OF TOTAL CAPACITY) FLOW RATE FOR 1 MINUTE FLOW RATE FOR 2 MINUTE 16" x 19" x 13.5" 16" x 19" x 13.5" 16" x 19" x 13.5" 12,312 CUBIC INCHES 40 GAL 40 GPM OR 80 LBS. 20 GPM OR 40 LBS. (2 LB. RETENTION = 1 GPM /FLOW) *ZURN GREASE INTERCEPTOR MODEL GT2700 -25 HANDLES 25 GPM AND PROVIDES 50 LBS. OF CAPACITY. LANDLORD NOTES 1. ALL TENANTS ON THE GROUND FLOOR REQUIRING BELOW GRADE WORK SHALL COORDINATE WITH LANDLORD PRIOR TO ANY SLAB DEMOLITION. TENANT SHALL COORDINATE WITH LANDLORD TO PROVIDE OPPORTUNITY FOR SPECIAL INSPECTION AND PHOTOGRAPHIC DOCUMENTATION BY LANDLORD. OF BELOW GRADE WORK PRIOR TO THE COVERING UP OF SUCH WORK. TENANT SHALL BE RESPONSIBLE FOR RECONSTRUCTION AND PATCHING OF THE SLAB -ON -GRADE SYSTEM, INCLUDING GRAVEL LAYERS, VAPOR BARRIER, AND CONCRETE. 2. ALL FOOD SERVICE AND EXCESSIVE WATER USE TENANTS SHALL BE REQUIRED TO INSTALL A COLD WATER SUBMETER ASSEMBLY (REGISTERING IN GALLONS) WITH PRESSURE REGULATOR, GROUND JUMPER WIRE AND ALL FURTHER INSTALLATIONS AND CONNECTIONS, IN ACCORDANCE WITH ALL GIVEN REQUIREMENTS AT THE REAR PORTION OF THE TENANT SPACE IN A READILY ACCESSIBLE LOCATION, AT A MAXIMUM (48 ") ABOVE THE FINISHED FLOOR. 3. LANDLORD PROVIDED A CAPPED SANITARY VENT CONNECTION LOCATED WITHIN OR ADJACENT TO THE TENANT SPACE IN THE CEILING, VERIFY EXACT LOCATION IN FIELD. TENANT IS RESPONSIBLE TO EXTEND FROM THEIR SPACE TO POINT OF CONNECTION AT TENANT'S EXPENSE. 4. TENANT'S CONTRACTOR SHALL VERIFY POINTS OF CONNECTION FOR ALL VENT, SEWER, AND WATER PIPING WITH MALL MANAGEMENT BEFORE PROCEEDING WITH WORK. TENANT IS RESPONSIBLE FOR EXTENDING PIPING FROM POINT OF EXISTING CONNECTIONS TO TENANT SPACE AT TENANT'S EXPENSE. 5. TENANT TO SUBMIT FOR CODE VARIANCE REGARDING GREASE TRAP INSTALLATION REQUIREMENTS. n GO 00 MMT 0 0 PLUMBING PLAN- WATER eaus VC 1L0 1 char al Pin :. : Ga s pig City C f Tu < w ic il L i T. - IG D SOON PLUMBING KEYED NOTES 0 O WATER FILTER FOR ICE MACHINE AND HOT WATER MACHINE. LOCATE IN STOCK AREA IN EASILY ACCESSIBLE LOCATION. ® EXTEND AND CONNECT NEW 3" SANITARY PIPING TO LANDLORD'S SANITARY LINE. VERIFY EXACT LOCATION, SIZE, DEPTH, AND DIRECTION OF FLOW. O NEW WATTS MODEL #909 (OR EQUAL) RPZ BACK FLOW PREVENTER PROVIDED AND INSTALLED BY PLUMBING CONTRACTOR DOWNSTREAM OF WATER METER. ROUTE RELIEF VALVE PIPING TO MOP SINK, WITH CODE REQUIRED AIR GAP. COORDINATE EXACT LOCATION WITH LANDLORD. a4 EXTEND AND CONNECT NEW 1" COLD WATER PIPING TO LANDLORD'S EXISTING COLD WATER LINE IN CEILING SPACE BELOW. FIELD VERIFY EXACT LOCATION AND SIZE. ADJUST PIPING AS REQUIRED PER ACTUAL LOCATION OF COLD WATER PIPING STUB -IN. 0 EXTEND AND CONNECT NEW 2" VENT PIPING TO LANDLORD'S EXISTING VENT SYSTEM. FIELD VERIFY VERIFY EXACT LOCATION AND SIZE. O 1 /2" COLD WATER TO STOP VALVE WITH 3/8" OUTLET, THEN 3/8" COLD WATER TO WATER FILTER, THEN 1 /2" FILTER WATER OUT TO STOP VALVE 1 /4" OUTLET AND 1 /2" OUTLET. O ROUTE 1/4" FILTERED WATER PIPING FROM 1/4" FILTER WATER OUTLET TO 1/4" FITTING ON HOT WATER MACHINE. FIELD VERIFY LOCATION. FILTERED WATER STUB SHALL BE AT 48" A.F.F. O ROUTE 1/2" FILTERED WATER PIPING FROM 1/2" FILTER WATER OUTLET TO 3/8" FITTING ON ICE MACHINE MACHINE. FIELD VERIFY LOCATION. O NEW WALL MOUNTED HAND SINK. PROVIDE 1/2" COLD AND TEMPERED WATER PIPING. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. CI NEW 3 -COMP. SINK. PROVIDE 1/2" COLD AND 1/2" HOT WATER PIPING. ROUTE INDIRECT WASTE TO FLOOR SINK WITH CODE REQUIRED AIR GAP. FIELD VERIFY SIZE AND LOCATION. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. 0 NEW MOP SINK. PROVIDE 1/2" COLD AND 1/2" HOT WATER PIPING. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. CONTRACTOR SHALL PROVIDE A 5' -O" RUBBER HOSE ACCESSORY FOR MOP SINK. 12 NEW WATER HEATER. PROVIDE 3/4" COLD WATER INLET CONNECTION AND 3/4" HOT WATER OUTLET CONNECTION. ROUTE INDIRECT WASTE BELOW CEIUNG FROM TEMPERATURE & PRESSURE REDUCING VALVE AND DRAIN PAN TO MOP SINK WITH AIR GAP PER CODE. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. 13 NEW ICE MACHINE. ROUTE INDIRECT WASTE TO FLOOR SINK WITH AIR GAP PER CODE. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. 14 NEW ICE BIN. ROUTE INDIRECT WASTE TO FLOOR SINK WITH CODE REQUIRED AIR GAP. FIELD VERIFY SIZE AND LOCATION. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. 15 NEW BAR /HAND SINK. PROVIDE 1/2" COLD AND 1/2" TEMPERED WATER PIPING. ROUTE INDIRECT WASTE TO FLOOR SINK WITH CODE REQUIRED AIR GAP. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. 2 S 0 0 0 PLUMBING PLAN - WASTE/VENT El SCALE: 1/4? 1 16 NEW FLOOR SINK (TYPICAL OF 2). REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. 17 NEW THERMOSTATIC MIXING VALVE. REFER TO PLUMBING FIXTURE SCHEDULE FOR ADDITIONAL INFORMATION. 1$ 19 20 NEW 3" WALL CLEAN OUT. REFER TO SANITARY RISER DIAGRAM AND DETAIL FOR ADDITIONAL INFORMATION. NEW WATER SUBMETER SUPPLIED AND INSTALLED BY PLUMBING CONTRACTOR. COORDINATE EXACT TYPE AND LOCATION WITH LANDLORD. EXISTING FLOOR CLEAN -OUT. FIELD VERIFY EXACT LOCATION ANEYSIZE. NEW GREASE INTERCEPTOR RECESSED IN FLOOR. PROVIDE EXTENSIONS AS REQUIRED. SEE KITCHEN FIXTURE PLAN FOR ADDITIONAL INFORMATION. PLUMBING CONTRACTOR'S RTES ALL OF THE PLUMBING /PIPING WORK IS NOT NECESSARILY SHOWN OR NOTED ON THESE DRAWINGS. THE CONTRACTORS SHALL VISIT THE JOB SITE AND FIELD VERIFY ALL EXISTING CONDITIONS RELATED TO THE WORK PRIOR TO BIDDING. THOSE ITEMS NOT SHOWN OR NOTED BUT WHICH ARE DEEMED NECESSARY FOR REMOVAL OR RELOCATION BY OWNER OR HIS REPRESENTATIVE SHALL BE PART OF HIS CONTRACT. THE SUBMISSION OF THE PROPOSALS SHALL BE CONSIDERED EVIDENCE THAT THE CONTRACTORS HAVE VISITED THE SITE. NO EXTRA PAYMENTS WILL BE ALLOWED THESE CONTRACTORS ON ACCOUNT OF EXTRA WORK MADE NECESSARY BY HIS FAILURE TO VISIT THE JOB SITE. THE PLUMBING CONTRACTOR IS RESPONSIBLE FOR BACK FLOW PREVENTION VALVES AS REQUIRED BY CODE. TEVANA STORES DO NOT HAVE ANY FOOD PREPARATION AND IS NOT CONSIDERED A FOOD OR BEVERAGE SHOP. THE BEVERAGE PREPARATION ACCOUNTS LESS THAN 10% OF THE SALES ON AVERAGE, AND IS USED PRIMARYILY FOR CUSTOMERS TO FIND WHAT THEY WOULD LIKE FROM TEAVANA'S ASSORTMENT OF OVER 100 LOOSE TEAS. ALL BEVERAGES ARE SREVED IN DISPOSABLE CONTAINERS. FILE COPY Permit No Plar review approval is subject to errors and Approval of construsn doctunents does not the violation of any adopted code or ord lance. R of approved Fie _ and ��, , �% 'k alto I I/7V WASTE /VENT RISER DIAGRAM SCALE N.T.S. WATER FtlSER DIAGRAM �..ra PG0g..011 City of Tukwila BUILDING DIVISION P 6 - '7- FLOOR PENETRATION (TYPICAL) JAN 17 2008 P700 PLUNK FIXTURE & HEDUL.E 0 FIX URE DATA CONNECTION DATA PLAN TAG FIXTURE g MFG. MODEL NO. SOIL SIZE VENT SIZE TRAP INDIRECT WASTE • WATER DESCRIPTION COLD HOT TEMP. FILTER — - • • - - 0 FLOOR SINK 2 ZURN FD- 2377 -NH3 -H 3" 2" 3" - -- - -- - -- - -- 1/2 GRATE (D BACKFLOW PREVENTER 1 WATTS GENERAL CONTRACTOR ___ ___ ___ TO FLOOR DRAIN 1 " ___ ___ ___ RPZ BACKFLOW PREVENTER FOR MAIN SERVICE. O ICE MACHINE 1 MANITOWOC S- SERIES 322 - -- - -- --- (1)3 TO F.S. - -- - -- - -- 3/8" MANITOWOC STORAGE BIN B -320, 1/2" INDIRECT WA5 r L TO F.S. 4 3- COMPARTMENT SINK 1 EAGLE GROUP 414- 16 -3 -18 - -- - -- - -- TO FLOOR SINK 1/2" 1 /2" ___ W /DOUBLE DRAIN BOARD EAGLE GROUP SPRAYER 300719. ® UNIVERSAL V MOP SINK 1 STAINLESS MOP -20 -8 2 " 2 " 2" 1/2" 1/2" - -- - -- UNIVERSAL STAINLESS SERVICE FAUCET SF -8, HOSE END WITH 5' -0" HOSE, VACUUM BREAKER, AND UNIVERSAL STAINLESS MOP HANGER MH -3. 6 THERMOSTATIC MIXING VALVE 1 SYMMONS 5 -130 ___ 3/4 IN 3/4" IN 3/4 OUT ___ PROVIDE UNIONS AND HAMMOND #8501H FULL PORT BALL VALVE. �'J 0 WALL MOUNTED HAND SINK 1 ELKAY CHS1716C 1 -1/2" 1 -1/2" 1 -1/2" 1/2" - -- 1/2" - -- ELKAY FAUCET LK499 (INCLUDED WITH SINK) ® BAR SINK 1 ADVANCE TABCO DI -1 -25 - -- - -- - -- 1 -1/2" TO F.S. 1/2" - -- 1/2" - -- W /K -62 ADVANCE TABCO FAUCET BAR SINK IS NSF CERTIFIED. O HOT WATER MACHINE 1 BUNN H1OX - -- - -- - -- - -- - -- - -- 1/4" 1 D WATER HEATER 1 RHEEM EGSP20 - -- - -- - -- 3/4" 3/ S P 3 / 4 " 3/4" 3/4 _ - _ _....... 19.9 - GALLON, TEMPERATURE 40'F IN AND 140 "F OUT, 6,000 WATTS, 208V 1PH, 98% EFFICIENCY RATING. 11 WALL CLEANOUT 1 *J.R. SMITH 12 W A T E R FILTER 1 MANITOWOC AR20000 - -- - -- - -- 1/2" IN ___ ___ 1/2" OUT PROVIDED BY OWNER, INSTALLED BY CONTRACTOR. @ NOT USED 14 O ICE BIN 1 MOLI INTERNATIONAL BIB-1418 ___ ___ ___ 1 -1 2 TO F S. ___ - -- ___ __ _ 15 FLOOR CLEANOUT 1 *J.R. SMITH q" - -- - -- - -- - -- - -- - -- 16 DROP —IN HAN DSINK 1 ADVANCE TABCO p1 -1 -5 __ ___ ___ 1 -1/2" TO F.S. 1/2" - -- 1/2" - -- W /K -62 ADVANCE TABCO FAUCET SINK IS NSF CERTIFIED. ® INTERIOR GREASE TRA 1 *ZURN GT2700 -25 3 - -- --- --- - -- PROVIDED AND INSTALLED BY CONTRACTOR 21 DFLRAIOON R 1 ZURN Z504- 3 -ZN -Y 3" 2" 3" - -- - -- - -- - -- © NEW 25 GPM VENTED FLOW CONTROL VALVE PROVIDED AND INSTALLED BY CONTRACTOR * OR GENERAL NOTES: 1. REFER TO SHEET FIXTURE PLAN FOR FAUCETS, FURNISHING AND INSTALLATION RESPONSIBILITIES. 2. INSTALL FIXTURES, FITTINGS, AND ACCESSORIES PER MANUFACTURER'S INSTRUCTIONS. 3. INSTALL EACH FIXTURE WITH TRAP, LOOSE KEY STOPS, FLEXIBLE SUPPLIES, REDUCERS, AND ESCUTCHEONS. APPROVED EQUAL PLUMBING GENERAL NOTES ALL PLUMBING WORK TO COMPLY WITH ALL APPLICABLE CODES AND LANDLORD CRITERIA. ALL HOT AND COLD PIPING AND FITTINGS SHALL BE INSULATED WITH 1/2" THICK SNAP ON FIBERGLASS INSULATION WITH CANVAS JACKET COVER COLD WATER PIPING INSULATION SHALL INCLUDE VAPOR BARRIER JACKET SEALED WITH CEMENT. STERILIZATION OF DOMESTIC WATER SYSTEM. BEFORE BEING PLACED IN SERVICE ALL WATER LINES SHALL BE CHLORINATED TO THE SATISFACTION OF THE ENGINEER IN ACCORDANCE WITH AWWA SPEC C60 -53T. PROVIDE ACCESSIBLE SHUT -OFF VALVES AT ALL PLUMBING FIXTURES. WATER VALVES TO BE JENKINS #476 OR EQUAL. INSTALL SHOCK ABSORBERS ON ALL HOT AND COLD WATER BRANCH LINES TO PLUMBING FIXTURES AND EQUIPMENT. SANITARY AND VENT PIPING SHALL BE SERVICE WEIGHT CAST IRON NO -HUB WITH CAST IRON FITTINGS WITH STAINLESS STEEL NO -HUB COUPLINGS NEOPRENE GASKET. NO PVC PIPING IS PERMITTED. SOLDER JOINT FITTINGS USING 95 -5 LEAD FREE SOLDER. WATER PIPING ABOVE GRADE SHALL CONSIST OF TYPE "L" HARD COPPER TUBING WITH WROUGHT COPPER FITTINGS USING SILVER SOLDER. INSTALL WATER METER AS REQUIRED BY APPLICABLE CODES, UTILITY COMPANY, AND LANDLORD REQUIREMENTS. ESCUTCHEONS: PROVIDE EXPOSED PIPING, BOTH BARE AND COVERED WITH CP CAST BRASS ESCUTCHEONS WHERE PASSING THROUGH FLOORS, CEILINGS, WALLS OR PARTITIONS. SUPPORT HORIZONTAL DRAINAGE PIPING AT LEAST EVERY 5' -0" OR AT EVERY HUB, COPPER TUBING EVERY 7' -0" AND STEEL PIPE EVERY 10' -0" WITH CLEVIS HANGER AND INSULATION PROTECTION SHIELDS. PIPING SHALL NOT BE SUPPORTED FROM BRIDGING OR OTHER PIPING. TEST PIPING AND PROVE TIGHT FOR AT LEAST TWO HOURS IN ACCORDANCE WITH REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION AND OR AS SPECIFIED, TEST SHALL BE PERFORMED IN THE PRESENCE OF THE TENANT REPRESENTATIVE AND LOCAL INSPECTOR TEST SHALL BE REPEATED IF NECESSARY UNTIL FINAL APPROVAL OF SYSTEM IS OBTAINED. TEST DRAINAGE AND VENT PIPING BY FILLING WITH WATER TO OVERFLOWING. WATER LEVEL TO REMAIN CONSTANT. TEST WATER PIPING WITH WATER 13 TIMES THE WORKING PRESSURE. ALL SANITARY SEWER LINES TO BE SLOPED AT MINIMUM 1/4" PER FOOT. ALL PLUMBING FLOOR PENETRATIONS MUST HAVE "LINK SEALS" INSTALLED BEFORE MEMBRANE IS INSTALLED EXPOSED HORIZONTAL WATER PIPING SHALL BE INSTALLED IN ACCORDANCE WITH LOCAL HEALTH DEPT. CODE. PROVIDE WATER METER, REMOTE REGISTER READ IN CUBIC FEET, EASILY ACCESSIBLE TO MALL PERSONNEL. LOCATE IN BATHROOM OR STOCK ROOM. INTERIOR GREASE TRAP SIZING DIMENSIONS OF EACH BOWL OF 3- COMPARTMENT SINK TOTAL CAPACITY OF 3- COMPARTMENT SINK (TOTAL OF 3 BOWLS) CAPACITY IN GALLONS 53.3 GAL (DIVIDE BY 231) ACTUAL DRAINAGE LOAD (75% OF TOTAL CAPACITY) FLOW RATE FOR 1 MINUTE FLOW RATE FOR 2 MINUTE 16" x 19" x 13.5" 16" x 19" x 13.5" 16" x 19" x 13.5" 12,312 CUBIC INCHES 40 GAL 40 GPM OR 80 LBS. 20 GPM OR 40 LBS. (2 LB. RETENTION = 1 GPM /FLOW) *ZURN GREASE INTERCEPTOR MODEL GT2700 -25 HANDLES 25 GPM AND PROVIDES 50 LBS. OF CAPACITY. LANDLORD NOTES 1. ALL TENANTS ON THE GROUND FLOOR REQUIRING BELOW GRADE WORK SHALL COORDINATE WITH LANDLORD PRIOR TO ANY SLAB DEMOLITION. TENANT SHALL COORDINATE WITH LANDLORD TO PROVIDE OPPORTUNITY FOR SPECIAL INSPECTION AND PHOTOGRAPHIC DOCUMENTATION BY LANDLORD. OF BELOW GRADE WORK PRIOR TO THE COVERING UP OF SUCH WORK. TENANT SHALL BE RESPONSIBLE FOR RECONSTRUCTION AND PATCHING OF THE SLAB -ON -GRADE SYSTEM, INCLUDING GRAVEL LAYERS, VAPOR BARRIER, AND CONCRETE. 2. ALL FOOD SERVICE AND EXCESSIVE WATER USE TENANTS SHALL BE REQUIRED TO INSTALL A COLD WATER SUBMETER ASSEMBLY (REGISTERING IN GALLONS) WITH PRESSURE REGULATOR, GROUND JUMPER WIRE AND ALL FURTHER INSTALLATIONS AND CONNECTIONS, IN ACCORDANCE WITH ALL GIVEN REQUIREMENTS AT THE REAR PORTION OF THE TENANT SPACE IN A READILY ACCESSIBLE LOCATION, AT A MAXIMUM (48 ") ABOVE THE FINISHED FLOOR. 3. LANDLORD PROVIDED A CAPPED SANITARY VENT CONNECTION LOCATED WITHIN OR ADJACENT TO THE TENANT SPACE IN THE CEILING, VERIFY EXACT LOCATION IN FIELD. TENANT IS RESPONSIBLE TO EXTEND FROM THEIR SPACE TO POINT OF CONNECTION AT TENANT'S EXPENSE. 4. TENANT'S CONTRACTOR SHALL VERIFY POINTS OF CONNECTION FOR ALL VENT, SEWER, AND WATER PIPING WITH MALL MANAGEMENT BEFORE PROCEEDING WITH WORK. TENANT IS RESPONSIBLE FOR EXTENDING PIPING FROM POINT OF EXISTING CONNECTIONS TO TENANT SPACE AT TENANT'S EXPENSE. 5. TENANT TO SUBMIT FOR CODE VARIANCE REGARDING GREASE TRAP INSTALLATION REQUIREMENTS. n GO 00 MMT 0 0 PLUMBING PLAN- WATER eaus VC 1L0 1 char al Pin :. : Ga s pig City C f Tu < w ic il L i T. - IG D SOON PLUMBING KEYED NOTES 0 O WATER FILTER FOR ICE MACHINE AND HOT WATER MACHINE. LOCATE IN STOCK AREA IN EASILY ACCESSIBLE LOCATION. ® EXTEND AND CONNECT NEW 3" SANITARY PIPING TO LANDLORD'S SANITARY LINE. VERIFY EXACT LOCATION, SIZE, DEPTH, AND DIRECTION OF FLOW. O NEW WATTS MODEL #909 (OR EQUAL) RPZ BACK FLOW PREVENTER PROVIDED AND INSTALLED BY PLUMBING CONTRACTOR DOWNSTREAM OF WATER METER. ROUTE RELIEF VALVE PIPING TO MOP SINK, WITH CODE REQUIRED AIR GAP. COORDINATE EXACT LOCATION WITH LANDLORD. a4 EXTEND AND CONNECT NEW 1" COLD WATER PIPING TO LANDLORD'S EXISTING COLD WATER LINE IN CEILING SPACE BELOW. FIELD VERIFY EXACT LOCATION AND SIZE. ADJUST PIPING AS REQUIRED PER ACTUAL LOCATION OF COLD WATER PIPING STUB -IN. 0 EXTEND AND CONNECT NEW 2" VENT PIPING TO LANDLORD'S EXISTING VENT SYSTEM. FIELD VERIFY VERIFY EXACT LOCATION AND SIZE. O 1 /2" COLD WATER TO STOP VALVE WITH 3/8" OUTLET, THEN 3/8" COLD WATER TO WATER FILTER, THEN 1 /2" FILTER WATER OUT TO STOP VALVE 1 /4" OUTLET AND 1 /2" OUTLET. O ROUTE 1/4" FILTERED WATER PIPING FROM 1/4" FILTER WATER OUTLET TO 1/4" FITTING ON HOT WATER MACHINE. FIELD VERIFY LOCATION. FILTERED WATER STUB SHALL BE AT 48" A.F.F. O ROUTE 1/2" FILTERED WATER PIPING FROM 1/2" FILTER WATER OUTLET TO 3/8" FITTING ON ICE MACHINE MACHINE. FIELD VERIFY LOCATION. O NEW WALL MOUNTED HAND SINK. PROVIDE 1/2" COLD AND TEMPERED WATER PIPING. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. CI NEW 3 -COMP. SINK. PROVIDE 1/2" COLD AND 1/2" HOT WATER PIPING. ROUTE INDIRECT WASTE TO FLOOR SINK WITH CODE REQUIRED AIR GAP. FIELD VERIFY SIZE AND LOCATION. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. 0 NEW MOP SINK. PROVIDE 1/2" COLD AND 1/2" HOT WATER PIPING. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. CONTRACTOR SHALL PROVIDE A 5' -O" RUBBER HOSE ACCESSORY FOR MOP SINK. 12 NEW WATER HEATER. PROVIDE 3/4" COLD WATER INLET CONNECTION AND 3/4" HOT WATER OUTLET CONNECTION. ROUTE INDIRECT WASTE BELOW CEIUNG FROM TEMPERATURE & PRESSURE REDUCING VALVE AND DRAIN PAN TO MOP SINK WITH AIR GAP PER CODE. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. 13 NEW ICE MACHINE. ROUTE INDIRECT WASTE TO FLOOR SINK WITH AIR GAP PER CODE. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. 14 NEW ICE BIN. ROUTE INDIRECT WASTE TO FLOOR SINK WITH CODE REQUIRED AIR GAP. FIELD VERIFY SIZE AND LOCATION. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. 15 NEW BAR /HAND SINK. PROVIDE 1/2" COLD AND 1/2" TEMPERED WATER PIPING. ROUTE INDIRECT WASTE TO FLOOR SINK WITH CODE REQUIRED AIR GAP. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. 2 S 0 0 0 PLUMBING PLAN - WASTE/VENT El SCALE: 1/4? 1 16 NEW FLOOR SINK (TYPICAL OF 2). REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. 17 NEW THERMOSTATIC MIXING VALVE. REFER TO PLUMBING FIXTURE SCHEDULE FOR ADDITIONAL INFORMATION. 1$ 19 20 NEW 3" WALL CLEAN OUT. REFER TO SANITARY RISER DIAGRAM AND DETAIL FOR ADDITIONAL INFORMATION. NEW WATER SUBMETER SUPPLIED AND INSTALLED BY PLUMBING CONTRACTOR. COORDINATE EXACT TYPE AND LOCATION WITH LANDLORD. EXISTING FLOOR CLEAN -OUT. FIELD VERIFY EXACT LOCATION ANEYSIZE. NEW GREASE INTERCEPTOR RECESSED IN FLOOR. PROVIDE EXTENSIONS AS REQUIRED. SEE KITCHEN FIXTURE PLAN FOR ADDITIONAL INFORMATION. PLUMBING CONTRACTOR'S RTES ALL OF THE PLUMBING /PIPING WORK IS NOT NECESSARILY SHOWN OR NOTED ON THESE DRAWINGS. THE CONTRACTORS SHALL VISIT THE JOB SITE AND FIELD VERIFY ALL EXISTING CONDITIONS RELATED TO THE WORK PRIOR TO BIDDING. THOSE ITEMS NOT SHOWN OR NOTED BUT WHICH ARE DEEMED NECESSARY FOR REMOVAL OR RELOCATION BY OWNER OR HIS REPRESENTATIVE SHALL BE PART OF HIS CONTRACT. THE SUBMISSION OF THE PROPOSALS SHALL BE CONSIDERED EVIDENCE THAT THE CONTRACTORS HAVE VISITED THE SITE. NO EXTRA PAYMENTS WILL BE ALLOWED THESE CONTRACTORS ON ACCOUNT OF EXTRA WORK MADE NECESSARY BY HIS FAILURE TO VISIT THE JOB SITE. THE PLUMBING CONTRACTOR IS RESPONSIBLE FOR BACK FLOW PREVENTION VALVES AS REQUIRED BY CODE. TEVANA STORES DO NOT HAVE ANY FOOD PREPARATION AND IS NOT CONSIDERED A FOOD OR BEVERAGE SHOP. THE BEVERAGE PREPARATION ACCOUNTS LESS THAN 10% OF THE SALES ON AVERAGE, AND IS USED PRIMARYILY FOR CUSTOMERS TO FIND WHAT THEY WOULD LIKE FROM TEAVANA'S ASSORTMENT OF OVER 100 LOOSE TEAS. ALL BEVERAGES ARE SREVED IN DISPOSABLE CONTAINERS. FILE COPY Permit No Plar review approval is subject to errors and Approval of construsn doctunents does not the violation of any adopted code or ord lance. R of approved Fie _ and ��, , �% 'k alto I I/7V WASTE /VENT RISER DIAGRAM SCALE N.T.S. WATER FtlSER DIAGRAM �..ra PG0g..011 City of Tukwila BUILDING DIVISION P 6 - '7- FLOOR PENETRATION (TYPICAL) JAN 17 2008 P700 PLUMBING SYMBOLS SAN. SANITARY SEWER UNE GREASE WASTE LINE VENT UNE GAS LINE COLD WATER LINE HOT WATER LINE TEMPERED WATER LINE FILTERED WATER UNE SHUT -OFF VALVE BACKFLOW PREVENTER VENT THRU ROOF CAST IRON COLD WATER HOT WATER TEMPERED WATER FILTER WATER FLOOR SINK F.D. FLOOR DRAIN T.P.R.V. TEMPERATURE PRESSURE RELIEF VALVE P.O.C. POINT OF CONNECTION M.S. MOP SINK LAV. LAVATORY UR. URINAL W.C. WATER CLOSET _ A.F.F. ABOVE FINISHED FLOOR B.F.F. BELOW FINISHED FLOOR uM WATER METER _" 1 WATER HEATER F.C.O. FLOOR CLEAN OUT W.C.O. WALL CLEAN OUT' H.S. HAND SINK H.W.S. HAND WASH SINK D.H.S. DROP -IN HAND SINK B.S. BAR SINK - GW V - — - — - - • . -- - . - - - • - • • — - • • - - D❑ N V.T.R. C.I. C.W. H.W. T.W. F.W. F.S. PLUMBING GENERAL NOTES ALL PLUMBING WORK TO COMPLY WITH ALL APPLICABLE CODES AND LANDLORD CRITERIA. ALL HOT AND COLD PIPING AND FITTINGS SHALL BE INSULATED WITH 1/2" THICK SNAP ON FIBERGLASS INSULATION WITH CANVAS JACKET COVER COLD WATER PIPING INSULATION SHALL INCLUDE VAPOR BARRIER JACKET SEALED WITH CEMENT. STERILIZATION OF DOMESTIC WATER SYSTEM. BEFORE BEING PLACED IN SERVICE ALL WATER LINES SHALL BE CHLORINATED TO THE SATISFACTION OF THE ENGINEER IN ACCORDANCE WITH AWWA SPEC C60 -53T. PROVIDE ACCESSIBLE SHUT -OFF VALVES AT ALL PLUMBING FIXTURES. WATER VALVES TO BE JENKINS #476 OR EQUAL. INSTALL SHOCK ABSORBERS ON ALL HOT AND COLD WATER BRANCH LINES TO PLUMBING FIXTURES AND EQUIPMENT. SANITARY AND VENT PIPING SHALL BE SERVICE WEIGHT CAST IRON NO -HUB WITH CAST IRON FITTINGS WITH STAINLESS STEEL NO -HUB COUPLINGS NEOPRENE GASKET. NO PVC PIPING IS PERMITTED. SOLDER JOINT FITTINGS USING 95 -5 LEAD FREE SOLDER. WATER PIPING ABOVE GRADE SHALL CONSIST OF TYPE "L" HARD COPPER TUBING WITH WROUGHT COPPER FITTINGS USING SILVER SOLDER. INSTALL WATER METER AS REQUIRED BY APPLICABLE CODES, UTILITY COMPANY, AND LANDLORD REQUIREMENTS. ESCUTCHEONS: PROVIDE EXPOSED PIPING, BOTH BARE AND COVERED WITH CP CAST BRASS ESCUTCHEONS WHERE PASSING THROUGH FLOORS, CEILINGS, WALLS OR PARTITIONS. SUPPORT HORIZONTAL DRAINAGE PIPING AT LEAST EVERY 5' -0" OR AT EVERY HUB, COPPER TUBING EVERY 7' -0" AND STEEL PIPE EVERY 10' -0" WITH CLEVIS HANGER AND INSULATION PROTECTION SHIELDS. PIPING SHALL NOT BE SUPPORTED FROM BRIDGING OR OTHER PIPING. TEST PIPING AND PROVE TIGHT FOR AT LEAST TWO HOURS IN ACCORDANCE WITH REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION AND OR AS SPECIFIED, TEST SHALL BE PERFORMED IN THE PRESENCE OF THE TENANT REPRESENTATIVE AND LOCAL INSPECTOR TEST SHALL BE REPEATED IF NECESSARY UNTIL FINAL APPROVAL OF SYSTEM IS OBTAINED. TEST DRAINAGE AND VENT PIPING BY FILLING WITH WATER TO OVERFLOWING. WATER LEVEL TO REMAIN CONSTANT. TEST WATER PIPING WITH WATER 13 TIMES THE WORKING PRESSURE. ALL SANITARY SEWER LINES TO BE SLOPED AT MINIMUM 1/4" PER FOOT. ALL PLUMBING FLOOR PENETRATIONS MUST HAVE "LINK SEALS" INSTALLED BEFORE MEMBRANE IS INSTALLED EXPOSED HORIZONTAL WATER PIPING SHALL BE INSTALLED IN ACCORDANCE WITH LOCAL HEALTH DEPT. CODE. PROVIDE WATER METER, REMOTE REGISTER READ IN CUBIC FEET, EASILY ACCESSIBLE TO MALL PERSONNEL. LOCATE IN BATHROOM OR STOCK ROOM. INTERIOR GREASE TRAP SIZING DIMENSIONS OF EACH BOWL OF 3- COMPARTMENT SINK TOTAL CAPACITY OF 3- COMPARTMENT SINK (TOTAL OF 3 BOWLS) CAPACITY IN GALLONS 53.3 GAL (DIVIDE BY 231) ACTUAL DRAINAGE LOAD (75% OF TOTAL CAPACITY) FLOW RATE FOR 1 MINUTE FLOW RATE FOR 2 MINUTE 16" x 19" x 13.5" 16" x 19" x 13.5" 16" x 19" x 13.5" 12,312 CUBIC INCHES 40 GAL 40 GPM OR 80 LBS. 20 GPM OR 40 LBS. (2 LB. RETENTION = 1 GPM /FLOW) *ZURN GREASE INTERCEPTOR MODEL GT2700 -25 HANDLES 25 GPM AND PROVIDES 50 LBS. OF CAPACITY. LANDLORD NOTES 1. ALL TENANTS ON THE GROUND FLOOR REQUIRING BELOW GRADE WORK SHALL COORDINATE WITH LANDLORD PRIOR TO ANY SLAB DEMOLITION. TENANT SHALL COORDINATE WITH LANDLORD TO PROVIDE OPPORTUNITY FOR SPECIAL INSPECTION AND PHOTOGRAPHIC DOCUMENTATION BY LANDLORD. OF BELOW GRADE WORK PRIOR TO THE COVERING UP OF SUCH WORK. TENANT SHALL BE RESPONSIBLE FOR RECONSTRUCTION AND PATCHING OF THE SLAB -ON -GRADE SYSTEM, INCLUDING GRAVEL LAYERS, VAPOR BARRIER, AND CONCRETE. 2. ALL FOOD SERVICE AND EXCESSIVE WATER USE TENANTS SHALL BE REQUIRED TO INSTALL A COLD WATER SUBMETER ASSEMBLY (REGISTERING IN GALLONS) WITH PRESSURE REGULATOR, GROUND JUMPER WIRE AND ALL FURTHER INSTALLATIONS AND CONNECTIONS, IN ACCORDANCE WITH ALL GIVEN REQUIREMENTS AT THE REAR PORTION OF THE TENANT SPACE IN A READILY ACCESSIBLE LOCATION, AT A MAXIMUM (48 ") ABOVE THE FINISHED FLOOR. 3. LANDLORD PROVIDED A CAPPED SANITARY VENT CONNECTION LOCATED WITHIN OR ADJACENT TO THE TENANT SPACE IN THE CEILING, VERIFY EXACT LOCATION IN FIELD. TENANT IS RESPONSIBLE TO EXTEND FROM THEIR SPACE TO POINT OF CONNECTION AT TENANT'S EXPENSE. 4. TENANT'S CONTRACTOR SHALL VERIFY POINTS OF CONNECTION FOR ALL VENT, SEWER, AND WATER PIPING WITH MALL MANAGEMENT BEFORE PROCEEDING WITH WORK. TENANT IS RESPONSIBLE FOR EXTENDING PIPING FROM POINT OF EXISTING CONNECTIONS TO TENANT SPACE AT TENANT'S EXPENSE. 5. TENANT TO SUBMIT FOR CODE VARIANCE REGARDING GREASE TRAP INSTALLATION REQUIREMENTS. n GO 00 MMT 0 0 PLUMBING PLAN- WATER eaus VC 1L0 1 char al Pin :. : Ga s pig City C f Tu < w ic il L i T. - IG D SOON PLUMBING KEYED NOTES 0 O WATER FILTER FOR ICE MACHINE AND HOT WATER MACHINE. LOCATE IN STOCK AREA IN EASILY ACCESSIBLE LOCATION. ® EXTEND AND CONNECT NEW 3" SANITARY PIPING TO LANDLORD'S SANITARY LINE. VERIFY EXACT LOCATION, SIZE, DEPTH, AND DIRECTION OF FLOW. O NEW WATTS MODEL #909 (OR EQUAL) RPZ BACK FLOW PREVENTER PROVIDED AND INSTALLED BY PLUMBING CONTRACTOR DOWNSTREAM OF WATER METER. ROUTE RELIEF VALVE PIPING TO MOP SINK, WITH CODE REQUIRED AIR GAP. COORDINATE EXACT LOCATION WITH LANDLORD. a4 EXTEND AND CONNECT NEW 1" COLD WATER PIPING TO LANDLORD'S EXISTING COLD WATER LINE IN CEILING SPACE BELOW. FIELD VERIFY EXACT LOCATION AND SIZE. ADJUST PIPING AS REQUIRED PER ACTUAL LOCATION OF COLD WATER PIPING STUB -IN. 0 EXTEND AND CONNECT NEW 2" VENT PIPING TO LANDLORD'S EXISTING VENT SYSTEM. FIELD VERIFY VERIFY EXACT LOCATION AND SIZE. O 1 /2" COLD WATER TO STOP VALVE WITH 3/8" OUTLET, THEN 3/8" COLD WATER TO WATER FILTER, THEN 1 /2" FILTER WATER OUT TO STOP VALVE 1 /4" OUTLET AND 1 /2" OUTLET. O ROUTE 1/4" FILTERED WATER PIPING FROM 1/4" FILTER WATER OUTLET TO 1/4" FITTING ON HOT WATER MACHINE. FIELD VERIFY LOCATION. FILTERED WATER STUB SHALL BE AT 48" A.F.F. O ROUTE 1/2" FILTERED WATER PIPING FROM 1/2" FILTER WATER OUTLET TO 3/8" FITTING ON ICE MACHINE MACHINE. FIELD VERIFY LOCATION. O NEW WALL MOUNTED HAND SINK. PROVIDE 1/2" COLD AND TEMPERED WATER PIPING. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. CI NEW 3 -COMP. SINK. PROVIDE 1/2" COLD AND 1/2" HOT WATER PIPING. ROUTE INDIRECT WASTE TO FLOOR SINK WITH CODE REQUIRED AIR GAP. FIELD VERIFY SIZE AND LOCATION. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. 0 NEW MOP SINK. PROVIDE 1/2" COLD AND 1/2" HOT WATER PIPING. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. CONTRACTOR SHALL PROVIDE A 5' -O" RUBBER HOSE ACCESSORY FOR MOP SINK. 12 NEW WATER HEATER. PROVIDE 3/4" COLD WATER INLET CONNECTION AND 3/4" HOT WATER OUTLET CONNECTION. ROUTE INDIRECT WASTE BELOW CEIUNG FROM TEMPERATURE & PRESSURE REDUCING VALVE AND DRAIN PAN TO MOP SINK WITH AIR GAP PER CODE. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. 13 NEW ICE MACHINE. ROUTE INDIRECT WASTE TO FLOOR SINK WITH AIR GAP PER CODE. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. 14 NEW ICE BIN. ROUTE INDIRECT WASTE TO FLOOR SINK WITH CODE REQUIRED AIR GAP. FIELD VERIFY SIZE AND LOCATION. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. 15 NEW BAR /HAND SINK. PROVIDE 1/2" COLD AND 1/2" TEMPERED WATER PIPING. ROUTE INDIRECT WASTE TO FLOOR SINK WITH CODE REQUIRED AIR GAP. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. 2 S 0 0 0 PLUMBING PLAN - WASTE/VENT El SCALE: 1/4? 1 16 NEW FLOOR SINK (TYPICAL OF 2). REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. 17 NEW THERMOSTATIC MIXING VALVE. REFER TO PLUMBING FIXTURE SCHEDULE FOR ADDITIONAL INFORMATION. 1$ 19 20 NEW 3" WALL CLEAN OUT. REFER TO SANITARY RISER DIAGRAM AND DETAIL FOR ADDITIONAL INFORMATION. NEW WATER SUBMETER SUPPLIED AND INSTALLED BY PLUMBING CONTRACTOR. COORDINATE EXACT TYPE AND LOCATION WITH LANDLORD. EXISTING FLOOR CLEAN -OUT. FIELD VERIFY EXACT LOCATION ANEYSIZE. NEW GREASE INTERCEPTOR RECESSED IN FLOOR. PROVIDE EXTENSIONS AS REQUIRED. SEE KITCHEN FIXTURE PLAN FOR ADDITIONAL INFORMATION. PLUMBING CONTRACTOR'S RTES ALL OF THE PLUMBING /PIPING WORK IS NOT NECESSARILY SHOWN OR NOTED ON THESE DRAWINGS. THE CONTRACTORS SHALL VISIT THE JOB SITE AND FIELD VERIFY ALL EXISTING CONDITIONS RELATED TO THE WORK PRIOR TO BIDDING. THOSE ITEMS NOT SHOWN OR NOTED BUT WHICH ARE DEEMED NECESSARY FOR REMOVAL OR RELOCATION BY OWNER OR HIS REPRESENTATIVE SHALL BE PART OF HIS CONTRACT. THE SUBMISSION OF THE PROPOSALS SHALL BE CONSIDERED EVIDENCE THAT THE CONTRACTORS HAVE VISITED THE SITE. NO EXTRA PAYMENTS WILL BE ALLOWED THESE CONTRACTORS ON ACCOUNT OF EXTRA WORK MADE NECESSARY BY HIS FAILURE TO VISIT THE JOB SITE. THE PLUMBING CONTRACTOR IS RESPONSIBLE FOR BACK FLOW PREVENTION VALVES AS REQUIRED BY CODE. TEVANA STORES DO NOT HAVE ANY FOOD PREPARATION AND IS NOT CONSIDERED A FOOD OR BEVERAGE SHOP. THE BEVERAGE PREPARATION ACCOUNTS LESS THAN 10% OF THE SALES ON AVERAGE, AND IS USED PRIMARYILY FOR CUSTOMERS TO FIND WHAT THEY WOULD LIKE FROM TEAVANA'S ASSORTMENT OF OVER 100 LOOSE TEAS. ALL BEVERAGES ARE SREVED IN DISPOSABLE CONTAINERS. FILE COPY Permit No Plar review approval is subject to errors and Approval of construsn doctunents does not the violation of any adopted code or ord lance. R of approved Fie _ and ��, , �% 'k alto I I/7V WASTE /VENT RISER DIAGRAM SCALE N.T.S. WATER FtlSER DIAGRAM �..ra PG0g..011 City of Tukwila BUILDING DIVISION P 6 - '7- FLOOR PENETRATION (TYPICAL) JAN 17 2008 P700 NEW PLUMBING RXTURE CALCULATIONS PLUMBING FIXTURE QUANTITY DRAINAGE FIXTURE UNIT EA. DRAINAGE FIXT. UNIT TOTAL VENT SIZE EACH WATER SUPPLY FIXT. UNITS EACH WATER SUPPLY FIXT. UNITS TOTAL FLOOR SINK 2 3 6 2" -- ---- FLOOR DRAIN 1 3 3 2" -- -- *ICE MACHINE 1 -- -- -- 1 1 *ICE BIN 1 -- -- -- -- -- 3 -COMP SINK 1 4 4 -- 3 3 MOP SINK 1 3 3 2" 3 3 HAND SINK 1 1 2 1-1/2" 1 1 *BAR SINK 2 -- -- 1-1/2" 1 2 HOT WATER MACHINE 1 -- -- -- 0.5 0.5 TOTALS SERVICE CONNECTION SIZE 18 -- 10.5 SAN. VENT C.W. 4" 3" 1" FINISH FLOOR 2" VENT. ROUTE AT 45 DEGREE ANGLE TO WALL AND UP TO NEAREST VENT ABOVE CEILING. SINK FLOW CONTROL-' 3" INLET VALVE WITH VENT CI GREASE TRAP DETAIL ACCESS COVER 2" VENT UP IN WALL WALL 3" OUTLET GREASE TRAP (SEE SCHEDULE FOR CAPACITY) n LANDLORD NOTES 1. LANDLORD PROVIDES " COLD WATER SERVICE VALVED /CAPPED TO TENANTS SPACE. 1 " CW SERVICE SIZE REQUIRED PER PLUMBING CALCULATIONS. TENANT SHALL BE RESPONSIBLE FOR INCREASED COLD WATER SERVICE SIZE. TENANT'S CONTRACTOR SHALL FIELD VERIFY WITH TENANT COORDINATOR PIPING MAIN LOCATION AND EXTENT OF NEW PIPING REQUIRED. PIPE HANGER DETAIL SCAM MOPE PIPE INSULATION INSULATION SHALL BE RUN CONTINUOUS THRU HANGERS INSULATION PROTECTION SHIELD. USE 16 GAUGE SHEET STEEL, 2 PIPE DIAMETERS LONG, 120 DEGREES SUPPORT, OR GRINNEL FIGURE 167. SERVICE FAUCET WITH VACUUM BREAKER MOP HANGER HOSE BRACKET 4-N 24" MOP 8INK DETAIL I SCALE NONE �x7 oil 0_ 60" RUBBER HOSE SUPPLIED AND INSTALLED BY TENANT'S PLUMBING CONTRACTOR APPLY SILICONE SEALANT BETWEEN MOP SINK AND ADJACENT SURFACES 0 N 3/4" T &P DRAIN. ROUTE PER LANDLORD'S DIRECTIONS. GATE VALVE (TYP.) ELECTRIC UNION (TYP.) W H EAT E R T & P RELIEF VALVE. DISCHARGE TO PAN 24 "x24 "x9" GALV. SHEET METAL (16 GA) DRAIN PAN MOUNTING SHELF WATER HEATER MOUNTING DETAIL SCALE NONE INSTALL FLUSH W/ FINISHED FLOOR FLOOR SINK DETAIL FIN. FLOOR m it,gr�/■ % ■% /■%■rommov �: rimer, / 4 r 1 NOTE: 1. ALL FLOOR SINKS MUST BE FLUSH WITH TILE FLOOR AS SHOWN ABOVE METAL GRATE TO BE 1/2 WITH 1/2 LEFT OPEN. CAST IRON FLOOR DRAIN 5LB. LEAD FLASHING SHALL BE FORMED TO CHIPPED CONCRETE WITH A POSffIVE SLOPE TO CLAMP DEVICE. PROVIDE NON - SHRINK SPOUT UNDER LEAD FLASHING AS REQUIRED TO FACILITATE POSITIVE SLOPE (ANY FLASHING MATERIALS OTHER THAN LEAD IS UNACCEPTABLE. MINIMUM WIDTH OF FLASHING SHALL BE 24 "). ADJUSTABLE FINISH FLOOR STRAINER SLOPE TO DRAIN CORE DRILL 10 "O AND 4 "93 HOLES THREADED OR CAULK OUTLET OUTLET NOTE: THE GENERAL CONTRACTOR SHALL PROVIDE A ONE PIECE WATER PROOF MEMBRANE FLOOR AND BASE IN THE TOILET ROOM(S). FLOOR DRAIN DETAIL SCALE NO * INDIRECT WAS It CONNECTION CHROME WALLCOVER AND SCREW 1/8 BEND IF CLEANOUT OCCURS AT END OF LINE WALL CLEANOUT DETAIL etas NOM 1 G 0 2.1 MAY EXTEND AS WASTE OR VENT PLUGGED TEE w/ CLEANOUT FLOOR LINE 1/8 BEND WASTE LINE LENGTH TO SUIT WASTE LINE JAN 1 2006