Loading...
HomeMy WebLinkAboutPermit PG08-023 - BOEING #9-101BOEING #9 -101 9725 EAST MARGINAL WY S EXPIRED O8-1O-O8 PGO8-023 Parcel No.: Address: Suite No: City.f Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PLUMBING /GAS PIPING PERMIT 0003400018 9725 EAST MARGINAL WY S TUKW Permit Number: Issue Date: Permit Expires On: PG08 -023 02/12/2008 08/10/2008 Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: BOEING #9 -101 9725 EAST MARGINAL WAY A , TUKWILA WA BOEING COMPANY THE PROPERTY TAX DEPT , PO BOX 3707 M/C 20 -00 JOHN MURDOCH Address: PO BOX 3707 M/C 89 -14 , SEATTLE WA Contractor: Name: BOEING COMPANY Address: 100 N RIVERSIDE, M/C 5003 -4027 , CHICAGO IL Contractor License No: BOEINC *294ML Phone: Phone: 253 773 -0444 Phone: 312 544 -2535 Expiration Date: 01/14/2009 DESCRIPTION OF WORK: REMOVE (4) HVAC CONDENSATE PUMPS AND REPLACE WITH (4) GRAVITY DRAINS WITH TRAP PRIMER CONNECTIONS. DRAIN IS ROUTED THROUGH A FLOOR DRAIN IN UTILITY TRENCH (NO DIRECT CONNECTION). INSTALL WATTS SERIES 009 1/2' 0092T BACKFLOW PREVENTOR. Value of Plumbing /Gas Piping: $10,000.00 Uniform Plumbing Code Edition: 2006 Fees Collected: $112.00 International Fuel Gas Code Edition: 2006 FIXTURE TYPE AND QUANTITY Plumbing Bathtub or combination bath/shower 0 Bidet 0 Clothes washer, domestic 0 Dental unit, cuspidor 0 Dishwasher, domestic, with independent drain 0 Drinking fountain or water cooler (per head) 0 Food -waste grinder, commercial 0 Floor drain 0 Shower, single head trap 0 Lavatory 0 Wash fountain Receptor, indirect waste 0 Sinks 0 Urinals 0 Water Closet 0 0 Plumbing (cont.) Building sewer and each trailer park sewer 0 Rain water system - per drain (inside bldg) 0 Water heater and /or vent 0 Industrial waste treatment interceptor, including its trap and vent, except for kitchen type grease interceptors 0 Repair or alteration of water piping and/or water treatment equipment 0 Repair or alteration of drainage or vent piping 0 Medical gas piping system serving (1 -5) inlets /outlets for a specific gas 1 Medical gas piping (6 +) inlets /outlets 0 Gas Piping Gas piping outlets (0 -5) 0 Gas piping outlets (6 +) 0 * *continued on next page ** doc: UPC -10/06 PG08 -023 Printed: 02 -12 -2008 City otTukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: PG08 -023 Issue Date: 02/12/2008 Permit Expires On: 08/10/2008 Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied The granting construction lAndlatift ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. Date: 't does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating e of or . I am authorized to sign and obtain thisplplumbing /gas piping permit. �j (� lM / Date: l ? �:F.K �/�� � Signature: 14 4 Print Name: /va ! ry ` . frtft) ^, This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -10/06 PG08 -023 Printed: 02 -12 -2008 Parcel No.: 0003400018 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www:ci:tukwila.wa.us PERMIT CONDITIONS 9725 EAST MARGINAL WY S TUB:W BOEING #9 -101 Permit Number: Status: Applied Date: Issue Date: PG08 -023 ISSUED 01/24/2008 02/12/2008 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: ** *PUBLIC WORKS DEPARTMENT CONDTITONS * ** 14: Proposed WATTS Reduced Pressure Principle Assembly shall be installed per manufacturer's recommendations. * *continued on next page ** doc: Cond -10/06 PG08 -023 Printed: 02 -12 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: httpr / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the pe ; • rmance of work. ItIUC'dr� dat� fzFes$,t( Signature: ? S �� �' ��� e: if Print Name: E. itiontei/ doc: Cond -10/06 PG08 -023 Printed: 02 -12 -2008 CITY OF TUKWI Community Developmen epartment Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Plumbing/G . ' ermit No. -?(;)0 g - Oa 3 Project No. • (or office useorily), t PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION 6-, lot Ftb King Co Assessor's Tax No.: OW 14 b -QD Site Address: 97-Z6 CA �/ IOW 0. Suite Number: Floor: Tenant Name: The Gta, C99 4111 e Property Owners Name: G �1gb eOi rY Jl'A/ 5 wit e�j� Mailing Address: pa. Boles �7 _ ma Or- /`7 _ ,9177W it 96124 Z City State Zip New Tenant: W.... Yes 4No CONTACT NameVati4 6' _ Aitile rii TG Wig* Y Day Telephone: CO3 7 "f : ���'7% Mailing Address: Pe. Der 3:7 /v6 seatts Wit �,/w City Sate Zip E -Mail Address:L/011016• owid I1 ' /. a Fax Number: C ) '°61/1 PLUMBING .'/ GAS PIPING CONTRACTOR INFORMATION Company Name: I rIk ,415. eamio Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number:��C'�F ARCH pE T O; City Day Telephone: Fax Number: State Zip Expiration Date: 0 I /Cg All ;plans must betweetts 'stampedbyrArchiteet,of R�ecor . Company Name: Mailing Address: Contact Person: E -Mail Address: City Day Telephone: Fax Number: State Zip k* tie �* �. ,,x;A. .. - ,.,,,: meerioffRord� '. ',� ,... `, , _ ~ ..:ate .� •s. ^'°w,w:''' _ d.; %i Company Name: Mailing Address: Contact Person: E -Mail Address: Q:\Applicationss'Form "s- Applications On - Plumbing -Gas Piping Permit Application.dac Revised: 4 -2006 bh city Day Telephone: Fax Number: State Zip Page 1 of 2 o� Valuation of Project (contractor's bid price): $ `Qj�(�v .4 ,✓ / /�,� �r Scope of Work (please provide detailed information): i Mag C) f / c3Wty; VIti1 lid 7 feg q,m(/) Ever r piebv5 to of Tree Jfrkei. & eano 14 oui6D i7/f1 Rave i9lW 1N at flu 7 CLN (M Ayer c D*1t c 5141-1i WArr4 t ie oef9 ! 'agar 13tfierRotd, PRE P Building Use (per Intl Building Code): Occupancy (per Int'l Building Code): tr,2 /5 Utility Purveyor: Water: Sewer: .,.. - Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture:'Type: - Qty - :Fiiettire Type: ;,Qty. ' -.Fixture Type . . Qty. Fixture Type; Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste pp `1'I�J� b�'���Civ,Y Clothes washer, domestic Floor drain • Sinks Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and /or vent Additional medical gas inlets /outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas :.*t tiVI�I.¢T'APPEre fiiON*NOTEga: 6 Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY a RJU' BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDIN Signature: AGENT: /NE `' /�����j� /� p �f / 'f `�j , f ( b,, 6 2 Date: p9" 1 (�� ,i(%fl ? 70: ,,� rDay fTeellephone �✓ �Mrt W'[ City State Zip Date Application Accepted: ( -.24 -0 g Date Application Expires: -1 -��- 0 8 Staff Initials: / �I� 1r /{ Q \Applications\Forms- Applications On Line\3.2006 - Plumbing -Gas Piping Permit Application.doc Revised: 4-2006 bh Page 2 of 2 • City of Tukwila ► Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 0003400018 Permit Number: PG08 -023 Address: 9725 EAST MARGINAL WY S TUKW Status: PENDING Suite No: Applied Date: 01/24/2008 Applicant: BOEING #9 -101 Issue Date: Receipt No.: R08 -00212 Payment Amount: $112.00 Initials: WER Payment Date: 01/24/2008 11:34 AM User ID: 1655 Balance: $0.00 Payee: BOEING TRUST ACCOUNT 000.386.908.03 TRANSACTION LIST: Type Method Description Amount Payment Other 112.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES PLUMBING - NONRES 000/345.830 20.00 000.322.103.00.0 92.00 Total: $112.00 7608 01/24 0710 TOTAL 0.00 doc: Receiot -06 Printed: 01 -24 -2008 ?G08.023 ABLE COPY Job Name Job Location 1-Lb twi6 Engineer / Approval -1 Azi1%3 3• A i wro a� M Series 009 Reduced Pressure Zone Assemblies Sizes: 1/4" - 3" (8 - 80mm) Series 009 Reduced Pressure Zone Assemblies are designed to protect potable water supplies in accordance with national plumbing codes and water authority requirements. This series can be used in a variety of installations, including the prevention of health hazard cross connections in piping systems or for con- tainment at the service line entrance. This series features two in -line, independent check valves, cap- tured springs and replaceable check seats with an intermediate relief valve. Its compact modular design facilitates easy mainte- nance and assembly access. Sizes 1/4" - 1" (8 - 25mm) shutoffs have tee handles. Features • Single access cover and modular check construction for ease of maintenance • Top entry - all internals immediately accessible • Captured springs for safe maintenance • Internal relief valve for reduced installation clearances • Replaceable seats for economical repair • Bronze body construction for durability 1/4" - 2" (8 - 50mm) • Fused epoxy coated cast iron body 21/2" and 3" (65 and 80mm) • Ball valve test cocks — screwdriver slotted 1/4" - 2" (8 - 50mm) • Large body passages provides low pressure drop • Compact, space saving design • No special tools required for servicing Specifications A Reduced Pressure Zone Assembly shall be installed at each potential health hazard location to prevent backflow due to backsiphonage and /or backpressure. The assembly shall con- sist of an internal pressure differential relief valve located in a zone between two positive seating check modules with cap- tured springs and silicone seat discs. Seats and seat discs shall be replaceable in both check modules and the relief valve. There shall be no threads or screws in the waterway exposed to line fluids. Service of all internal components shall be through a single access cover secured with stainless steel bolts. The assembly shall also include two resilient seated isolation valves, four resilient seated test cocks and an air gap drain fitting. The assembly shall meet the requirements of: USC Manual 8th Editiont; ASSE Std. 1013; AWWA Std. C511; CSA B64.4. Shall be a Watts Regulator Co. Series 009. tDoes not indicate approval status. Refer to Page 2 for approved sizes & models. ES -009 Contractor Approval Contractor's P.O. No. Representative JAN 2 4 2008 Test Cock No. 3 Ball Type Test Cocks Test Cock No 2 2" 009M2QTHC First Check Module Assembly is r.110 � i 'ij- � R.P. Zone l Asir Relief Valve Assembly Second Check Module Assembly Water Outlet Now Available WattsBox Insulated Enclosures. For more information, send for literature ES -WB. IMPORTANT. INQUIRE WITH GOVERNING AUTHORITIES FOR LOCAL INSTALLATION REQUIREMENTS ISO 9001 CERTff1ED WA' RS® REGULATOR USA: 815 Chestnut Sc., No. Andover, MA 01845 -6098; www.wattsreg.com Canada: 5435 North Service Rd., Burlington, ONT L7L 5H7; wwwwattsanada.ca Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without Incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold. • The Boeing Company P.O. Box 3707 Seattle, WA 9812.4 -2207 04 September 2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite 100 Tukwila, WA. 98188 Reference: Cancellation of Issued Permit PG08 -023. Located at 9725 East Marginal So. Tukwila, WA. 98108. The Boeing Company. Dear Permit Staff, Due to decisions by Boeing Management it was determined that Job # 160620 -00 location in Building 9 -101 was cancelled. Even though this permit has expired 10 August 2008 I wanted to let you know what transpired with this job. Sincerely, O1'LVV S. M u,rcloth C.P.T. The Boeing Company Workplace Services Code Compliance and Permitting P.O. Box 3707 M/C 89 -14 Seattle WA. 98124 -2207 (253) 773 -0444 Land Line (253) 740 -0214 Cell Phone (253) 773 -0119 FAX RECEIVED CITY OF TUKWILA SEP 0 5 2008 'FgmIT CENTER 07 -15 -2008 JOHN MURDOCH PO BOX 3707 M/C 89 -14 SEATTLE WA 98124 Department of Community Development RE: Permit No. PG08 -023 9725 EAST MARGINAL WY S TUKW Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records the above noted permit has not received a fmal inspection by the City of Tukwila Building Division. Per the Uniform Plumbing Code and/or International Fuel Gas Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or fmal inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Plumbing and/or Gas Code does allow the Building Official to approve one extension of time for an additional period not exceeding 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 08/10/2008 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, 44eta/ er Marshall, t Technician xc: Permit File No. PGO8 -023 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 • PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: PG08 -023 PROJECT NAME: BOEING #9 -101 SITE ADDRESS: 9725 EAST MARGINAL WAY S DATE: 01 -24 -08 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: 2s'I�� B I s g Dfliision 'j ubli Wo k Fire Prevention Structural Planning Division Permit Coordinator ERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 01 -29 -08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS RO TING: Please Route Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: DUE DATE: 02 -26-08 Not Approved (attach comments) Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Look Up a Contractor, Electri or Plumber License Detail Washington State Department of Labor and Industries General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. License Information License BOEINC *294ML Licensee Name BOEING COMPANY, THE Licensee Type CONSTRUCTION CONTRACTOR UBI 178005030 Ind. Ins. Account Id Business Type CORPORATION Address 1 100 N RIVERSIDE Address 2 M/C 5003 -4027 City CHICAGO County OUT OF STATE State IL Zip 606061596 Phone 3125442535 Status ACTIVE Specialty I GENERAL Specialty 2 UNUSED Effective Date 7/13/1971 Expiration Date 1/14/2009 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date SHRONTZ, F A 01/01/1980 CONDIT, P M 01/01/1980 GIVAN, B E 01/01/1980 WOODARD, R B 01/01/1980 CRUZE, D D 01/01/1980 KING, C G 01/01/1980 BEIGHLE, D P 01/01/1980 COLLINS, T J 01/01/1980 BUDINICH, T M 01/01/1980 Page 1 of 3 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= BOEINC *294ML, 02/12/2008 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED M DI TTMAR DRAWING I \SEX SHEET NO- DRAWING N0. SNEER SHEET TITLE REV. NO- DATE 1M138 9- 101 -1 M138 1ST FLOOR PLUMBING PLAN C C 11,27,07 11.27.07 TNM138 9- 101- TNM138 PARTIAL TUNNEL #14 - PARTIAL PIPING /PLUMBING PLAN TNM502 9- 101- TNM502 TUNNEL #14 - PLAN SECTION & DETAILS A 11.27.07 SEPARATE PERM i W.. REQUIRED FOR: 1 4 Mechanical . XElectrica Plumb4ng . 1 0 Gas Piping cit of Tukwila 1 t isi ; - ,r , - iVISICN .:.-. - - -__.. _ _ -_ ALE a Pe : L- 6 VA -?-, ,z -�. -�.- -- Plar review apnr ils s, � .e.,. a�.,Z Apprt�V4 th - I of . i... "ov 1 ;_� �. construction d ' � � � +���� �� : ���,�' documents does no! aul9aorize nfl„ a.e ,e,,,3 .... ..,_ Of app l and r. dions is acknowledged: C e . d opy �, ' _' A '. . 4,_-_,,,,, City or O BUILDING Df� iRIn � ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED M DI TTMAR DATE 08.02 CHECKED SNEER APPROVED BY DEPT. DATE CHECKED APPROVED APPROVED SYM A 9 -101.1 AHU #1H15A B C VICINITY vAP 99 0❑ 99 FROM SEATTLE- TACOMA AIRPORT EAST MARGINAL WAY CORPORATE PARK PROJECT SITE FROM DOWNTOWN SEATTLE 599 TUKWILA DEVELOPVE\TAL CE \TER 900 EXIT 157 rrt -o EXIT 158 FROM KENT & AUBURN NO SCALE EXIT 157 900 REVISION J #547077 -03 9- 101 M16 OFFICE RENOVATION J #160620 -00 BOEING WORKPLA BUILDING JOB #5899146 CLEAN ROOM A/C DRAIN P BY RWS LMC CFP APPROVED 9 -101 100K CLEANROOM MODS 5899146 RWS DATE 03.30.06 05.02.07 12.03.07 SYM AREA NAP BUILH\G ADDRESS: 9725 EAST vARGI \AL WAY SOUT TU <WILA, WAS I \GTO\ 9 -78 9-52 9 -35 0 9 -101 BUILDI\G LOCATIO\ NO SCALE REVISION BY APPROVED BOEING DEVELOPMEN 9725 EAST MARGINAL TUKWILA, WASHING DATE Z) L. O E /NG e � CE SERVICES 9 -101 1 ODIFIATION (LEAK REMEDIATION) TAL CENTER WAY SOUTH TON 98108 GE \ERAL OTES CONSTRUCTION SET OF DOCUMENTS, REVIEWED AND STAMPED BY CITY OF TUKWILA MUST BE ON SITE DURING CONSTRUCTION. DO NOT PROCEED WITH CONSTRUCTION WITHOUT ABOVE MENTIONED SET OF DOCUMENTS. 1. VERIFY ALL DIMENSIONS AND CONNECTIONS BEFORE ANY WORK. 2. NOTIFY FACILITY ENGINEERS SHOULD EXISTING CONDITIONS REQUIRE DESIGN REVISIONS. 3. COORDINATE WORK WITH OTHER CRAFTS. 4. RETURN THIS SAME SET TO JOHN MURDOCH AT BUILDING 9 -51.2 COLUMN M2., AFTER COMPLETION OF THIS CONSTRUCTION. PROJECT CHEC<LIST CHECK BOX E THESE DRAWINGS CONFORM TO THE 2006 I.B.C. CODES AND THE WAC 51 -20 AS ADAPTED OR AMENDED BY LOCAL ORDINANCES AND COMPLIANCE WITH CITY OF TUKWILA ZONING. E ROOMS LABELED PER OCCUPANCY PER I.B.C. 302.1. E BUILDING FLOOR NUMBER ON PRINT FOR AREA OF CONSTRUCTION. LI NUMBER OF PRINTS REQUIRED FOR PERMIT PACKAGE: El 1. GENERAL PERMIT (SHELL & CORE) ❑ 4 SETS OF STRUCTUAL REPLACEMENT DRAWINGS E 2. TENANT IMPROVEMENT (NON- STRUCTURAL): ❑ 3. TENANT IMPROVEMENT (REVISION), 2 SETS. ❑ 4. MECHANICAL, 4 COMPLETE SETS. ❑ 5. FIRE PROTECTION /SPRINKLERS, 3 COMPLETE SETS. E BRIEF PROJECT NARRATIVE: 1. RELACE 4 CONDENSATE PUMPS WITH GRAVITY DRAINS AND TRAPS AND PRIMERS. 2. INSTALL BACKFLOW PREVENTER SUBTITLE TITLE AUr; 10 CO�E S, V VARY LAND USE CODE TUKWILA BUILDING CODES 2006 I.B.C. CODES AND THE WAC 51 -20 AS ADAPTED OR AMENDED BY LOCAL ORDINANCES, AND COMPLIANCE WITH CITY OF TUKWILA ZONING. OCCUPANCY GROUP GROUP B AND GROUP F, DIVISION 1 (OFFICE AND FACTORY) CONSTRUCTION TYPE TYPE B, NON- COMBUSTIBLE SEPARATION 60 FEET (MINIMUM ALL SIDES) FLOOR AREAS: 295,878 (UNLIMITED PER IBC 507.3) BUILDING FOOTPRINT 713,829 BUILDING GROSS 1,116,306 TUNNEL 50,910 FIRST FLOOR 713,829 MEZZANINE 55,689 c, EFFECTED AREA 235 SF OF OFFICE BUILDING HEIGHT 111 FT. MAXIMUM STORIES 2 JAN 2 4 ZUM OCCUPANT LOAD: OVERALL (NO CHANGES) _ HANDICAPPED REQUIREMENTS BARRIER FREE FIRE PROTECTION FULLY AUTOMATIC, F/S CLASS 1 SPRINKLERS THROUGHOUT SEISMIC ZONE 3 MECHANICAL MASTER TITLE SHEET JOBS #160620 -00 BUILDING 9 -101 DEV. CENTER, WA DEV. CENTER, W CURRENT REVISION 5899146 SHEET JOB NO. DWG NO. Al SYMBOL 160620 -00 9- 101 --A1 nn u COMP NO. DATE 12.03.07 N) N F -v T T T T 1M110 1M111 1M112 1M113 1M114 1M115 1M116 1M117 1M118 1M119 1M120 1M121 1M122 1M123 1M124 1M125 1M126 1M127 1M128 1M129 1M130 1M131 1M132 1M133 ■ � — 1M134 1M135 1M136 1M137 1 M138 /f 1M139 1M140 1M141 1M142 1M143 rJ 1M144 1 1M145 1M146 SYM A EXTEND COMP. AIR & VAC B C REVISION CA & VAC CONN. (TYP 4 PLACES) 522109 -00 u 2" CONDENSATE DRAIN DOV q0 FL_DRAIW-I.N TUNNEL. "CA, (4' -2" A.F.F.) BY DMV APPROVED RWS /MM 2 "CA Km (NOT 1" DATE 03.08.02 SYM rr 1 3/8" DUPLEX PARKER QUICK COUPLER, E -Z -MATE SERIES EZ306M - 6T CD 1 i "CA DN TO CLEAN RM (NOTE 1) REVISION 5 TEST DRAIN 1 -1n r PW J L . DUPLEX OUTLET AND PIPING INSIDE HIGH BAY ON THE NORTH SIDE OF WALL AT X/19. SEE DWG 1M133 FOR CONTINUATION 1 1M138 1M508 ,,--- 1 Tn 1 —„ I- (LOCATED ON II CLEAN ROOM II ROOF.) L r BY 3" PW AHU -2 SEA LAUNCH CLEAN ROOM ROOF AREA (NOTE 1) INSTALL DUPLEX AIR OUTLET AS BUILT COMP. AIR & VAC LINES 4192708 LEAK REMEDIATION WO # 5899146 RWS S.RUDELL CFP RWS RWS 02.01.07 11/27/07 APPROVED PW DATE L - - - - - - —U 67 4 " ---- 4» 1 "CA DN TO FLR 1 "CA 3 "CA 1 "CA ei LiergerstrAw® � 1M138 1M508 AIR FILTER STATION a VAC 4 VAC A 3"VAC DUPLEX VACUUM TRIPLEX CA OUTLET OUTLET 1M138 1M508 1M138 1M508 FIRST FLOOR 4732 —M1 4732 —M5 1M138 4" COMPRESSED AIR & 4" VAC1 UP TO TRUSS. SEE DWG. 9- 101- CWM147 FOR CONTINUATION AIR DROPS, (2) i "& (1) " (TYP 4 PLCS) DRAIN DRAIN APPROVED BY U ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DEPT. SINK 4 "CW "HW 2"VENT 2 CA DATE -HOSE REEL HOT WATER HEATER 4" VENT UP & DN 2" AHU COIL COND. DRAIN UP & DN DRAWN CHECKED ENGINEER CHECKED APPROVED APPROVED DATE 3" 4 P6eosi 0 i5 CO \STRUCTI INSTALL NEW TRAP PRIMER WITH ELECTRIC TIMER, AS SPECIFIED IN BOAT NOTE 2. CONNECT TO VERTICAL REMNANT OF EXISTING DRAIN INSTALL NEW CITY WATER LINE CONNECT TO CITY WATWER IN TUNNEL - SEE 109 - 101- TNM138 FOR CONTINUATION INSTALL NEW BACKFLOW PREVENTER 10. LABEL NEW PIPING SEAL DUCTWORK ; \OTES (CO \T SUBTITLE TM.E TYPICAL CONDENSATE TRAP DETAIL (NQ SCALE) MECHANICAL MASTER i" TRAP PRIMER LINE 1ST FLR PLUMBING PLAN BUILDING 9 -101.1 COL. W— Z/19 -21 DEV. CENTER, WA LEGE \D GE \ERAS \OTES 1. CA LINE ROUTING TO OUTLETS TO BE DETERMINED & VERIFIED DURING CEILING TILE REMOVAL IN CLEAN ROOM AREAS AS NOTED. TRAP PRIMER: PRECISION PLUMBING PRODUCTS MODEL MPB -500 -115V (115 volt) WITH ENCLOSURE AND DU -4 DISTRIBUTER BACKFLOW PREVENTER: REDUCED PRESSURE TYPE, z ", QUARTER TURN BALL VALVES, UNION CONNECTIONS, AIR GAP FITTING; WATTS SERIES 909 REFERE \CE TIFF 109 -101B- 4632 -M1 TIFF 109 -101B- 4732 -M1 9- 101 -1M188 9- 101 -1M388 9- 101 -1M508 JAN 2 4 2008 9-101.1 SCALE: N.T.S. CURRENT REVISION 4192708 SHEET JOB NO. DWG NO. AUG 10 2008 DRAWI \GS CC \STR„CTIO \OTES RE -WORK [EXISTING CONDENSATE DRAIN AND CONNECT RTRAP PRIMER LINE. SEE DRAWING # SK567760 -1 NEW CONDENSATE LINE: CONNECT TO EXISTING DRAIN AT AIR HANDLER, RE- WORKING EXIST. TRAP. ROUTE OVER TOP OF 1" CONDUIT, THEN UNDER 4" CONDUIT TO NEW COLLECTOR AT EDGE OF ROOF (CONNECT WITH COPPER DWV WYE FITTINGS). FIT TIGHT TO BOTTOM OF 4" CONDUIT AGAINST THIN NEPOPRENE PAD. MAINTAIN CONTINUOUS SLOPE. NEW LOW POINT DRAIN. INSTALL WITH TRAP WITH 3" WEIR HEIGHT. NEW CONDENSATE DRAIN - SUSPEND FROM CHANNEL MOUNTED ON AND OVERHANGING ROOF (SALVAGE & RE -USE EXIST PUMPED CONDENSATE DRAIN) PLUMBING TRUSS SPACE PLAN PLUMBING 1st FLOOR PLAN PIPING 1st FLOOR PLAN DUST COLLECTION 1st FLOOR PLAN PLUMBING SECTIONS & DETAILS SYMBOL 1M138 DATE 9- 101.1 -1M138 COMP NO. 02.01.07 { - L,V T T T T TNM110 TNM111 TNM112 TNM11. TNM114 TNM115 TNM116 TNM117 TNM118 TNM11.c TNM120 TNM121 TNM122 TNM123 TNM124 TNM125 TNM126 TNM127 TNM128 TNM129 TNM130 TNM131 TNM132 TNM133 TNM134 TNM135 TNM136 TNM137 % / TAW 1 TNM140 TNM141 TNM142 TNM143 TNM1'4 TNM145 TNM146 --_ A -2" COPPER LEAK REMEDIATION wo # 5899146 SYM A INSTALL AIR & VACUUM LINES REVISION B DRAWING FIELD VERIFIED & UPDATED J #567760 -00 VAC BY M.WONG S.RUDELL CFP APPROVED R.SQUIRES RWS 1 1/2" COND. DRAIN FD DATE 10.11.07 11/27/07 • 1 SYM REVISION OPENINGS TO 7 FLR. ABOVE (TYP) VAC BY J [ APPROVED DATE CD CW 2 Q� BOE/ G C' JAMESBURRY 4" 51050 312200TT, 150# RAISED FACE & 4" ADAPTER FLANGE: PROPRESS 91577 & 4x2 XL BRONZE REDUCER FTGXC PROPRESS 91447 (TYP 2) ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY L 2 DEPT. DATE TNM138 & TNM 143 DRAWN SCHELLPFEFFER CHECKED SQUIRES ENGINEER SCHELLPFEFFER CHECKED APPROVED APPROVED PARTIAL PIPING PLAN / I 1 TNM502 DATE 05.05.04 05.05.04 05.05.04 SUBTITLE TITLE PARTIAL TUNNEL #14 PIPING /PLUMBING PLAN MECHANICAL MASTER BUILDING 9 -101 COL.W-Z/20-21 DEV. CENTER, WA LE \D A - CW - D CD HW PW IWP - V - RWL - SAN - VAC GE \ERAL REFERE CURRENT REVISION J #567760 -00 COMPRESSED AIR DOMESTIC COLD WATER DRAIN CONDENSATE DOMESTIC HOT WATER SUPPLY PROCESS WATER INDUSTRIAL WASTE PUMPED VENT RAIN WATER LEADER SANITARY WASTE VACUUM \OTES AUG 10 2008 CE DRAW \GS TIFF 109 -101B- 4607 —M1 PLUMBING UNDERGROUND PLAN 9- 101 --M313 CA & VAC. FLOW DIAGRAMS 9- 101— TNM143 TUNNEL PARTIAL PIPING /PLUMBING PLAN 9- 101— TNM137 TUNNEL PARTIAL PIPING /PLUMBING PLAN 9- 101-- TNM502 TUNNEL #14 PLAN, SECTIONS (Sc DETAILS CO\ STRJ INSTALL NEW CW LINE. SEE SHEETS 1M138 AND TNM 502 FOR CONTINUATION 2. LABEL NEW PIPING , TIO\ \OTES Om KEY PLAN SCALE: NONE SYMBOL SHEET TNMI38 cD JAN 2 4 c'f;C d DATE 11/26/ JOB NO. DWG NO. WO 5899146 9- 101- TNM138 COMP NO. SYM A TNM502 cL 2 CA — C E TNM502 LEAK REMEDIATION C TNM502 ▪ 4" VENT 2" WASTE � 1I"COND. REVISION f 4 "VAC . "CA A 00 PLU SCALE: 1/4" = 1' -0" 0 z Le- T V cw TUNNEL W v) A B I \ G PARTIAL PLA 4" VAC I 4" VAC I : Ti e k L e- U cw T TUNNEL TU \ \EL SECTI SCALE: 1 /2" = V-0" WO # 5899146 TNM502 Q 4" VAC J BY CFP J w t— U AIR FILTER Ic APPROVED RWS 4 "CA PIPING PARTIAL PLAN COALESCING AIR FILTER DETAIL TNM502 TNM500 SCALE: 1/4" = 1' -0" TNM143 & TNM138 TNM502 ro - D TNM502 1 "CW UP TO EWC -1 DATE 11/27/07 TNM143 & TNM138 TNM502 TNM143 TNM502 (1 TNM502 SYM 2"DRAIN FROM `� WASH FOUNTAIN 1 "CW UP TO FOUNTAIN 1ST FLOOR 4" VAC I 6" VAC II " TUNNEL FLOOR � / /j � / /\/``iVi��j/ % \ % \ \ " `. ,'\s; \ \ \� \ \\ . . : /` � 1 �� \ ;� � � T\ /� \ \� \/ /, //2\ \fi REVISION 1ST FLOOR FIN FLOOR EL. 15' -6" \; 4 SCALE: 1/2" = 1' -0" VACUMM OUTLET $n SWAGELOK QUICK DISCONN. MODEL# B- QC- 6 -D -6PF 4" BALL VA. (TYP) 4" SCRD. ADAPTER. M 4" TEE TUNNEL u . 2" PLUG TO VAC. LINE — Ct (EXP. LOOP) 2"VAC 1 i "LPC 2" WASTE 6"VACII TU\ \JEL SECTIO\ 1 "CW _L2 "WASTE BY APPROVED VAC & COvPRESSE TYPICAL DETAIL SCALE: NONE - j\ /- .2,• • 1i „ LPC 2 "CA B TNM142 TNM502 .-4” VAC I DATE 3" BALL VA. (TYP) 4" SCRD. ADAPTER. (TYP) FLOOR OPENING ABANDONED CW 0 4'VENT I U C TU k\ E L SECTIO\ SCALE: 1 /2" = 1 —0" -r (7' TO CA LINE 7 _4"VAC ABANDONED CW TL 3 AIR OLTLET (I 1 TNM502 FIN FLOOR EL. 15' -6" SCALE: 1/2" = 1 -0" 1ST FLOOR 11 "LPC 2 " "CA 2 "VAC A ] ABANDONED "CA • '"\WW / 4; 7( ,,,,"",„„ • A \ 1 � 1 TNM502 TUNNEL FLOOR i "x8 "x$" TEE r SCRD. ADAPTER. \EL SECT 0\ Q�BOE /NG c- WATTS AIR FILTER q 2"VAC "VAC CL �, TUNNEL Z COMPRESSED AIR OUTLET 4" QUICK DISCONN. INDUST. INTERCHNG. WITH "MPT PARKER SERIES 20 MODEL #22E ��1 4 n LPG �CL 2" &4 "CA TNM502 — 1 "CW \• 4 "CA U PLUG • ` � / f vi \�/ "X \ ✓ %\ g \ f / \ \//i i \ \ % / \ \ % \ / \� \/ %\ s \i \. , \ \<\\ \A\r I � 1 TNM502 (SIM.) TNM501 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN S.RUDELL CHECKED ENGINEER CHECKED APPROVED APPROVED DUPLEX -CA OUTLETS SIMPLEX -VAC I & AIR BEARING OUTLETS TO BE ACCESSIBLE FROM NEAREST FLOOR OPENINGS. FIN FLOOR EL. 1 d "LPC \ . fi ABANDONED 11" PUMPED �, CONDENSATE RETURN TU \NEL SECTION SCALE: 1/2" = 1' -0" FIN FLOOR EL. 15' -6" I L 1i (; L ABANDONED 14" PUMPED CONDENSATE RETURN 15'-6" TUNNEL VAC DRAIN POT DUPLEX -CA & VAC OUTLET DETAIL TNM502 % ` ?> _L1 1"VAC II 4 "CA CL4 "VAC I TNM142 TNM502 6" VAC II 4 "CA CE 4"VAC I Q6" VAC II A CL_ "CW TNM502 1 TNM501 TU \\EL SECTIO\ SCALE: 1 /2" = 1' -0" TNM1421TNM502 DATE 08.27.07 SUBTITLE TITLE MECHANICAL MASTER TUNNEL #14 PLAN, SECTIONS & DETAILS BUILDING 9 -101 COL. x—x/x—x LEGEND �E J DEV. CENTER, WA ERAL 1. SEE STRUCTURAL DWGS FOR TUNNEL AND TRENCH LOCATIONS & DIMENSIONS. REFERE TIFF 109 -101B- 4607 -M3 PLUMBING DETAILS TIFF 109 -101B- 4732 -M5 PLUMBING DETAILS TIFF 109 -101B- 4732 -M8 PLUMBING DETAILS 109 - 101- TNM145 TUNNEL PIPING /PLUMBING PLAN 109 - 101- TNM143 TUNNEL PIPING /PLUMBING PLAN 109 - 101- TNM137 TUNNEL PIPING /PLUMBING PLAN 109 - 101- TNM148 TUNNEL PIPING /PLUMBING PLAN 109 - 101- TNM500 TUNNEL SECTIONS & DETAILS 109 - 101- TNM501 TUNNEL SECTIONS & DETAILS 109 - 101 -M313 CA & VAC. FLOW DIAGRAMS A INSTALL NEW 2" CW LINE. FOR CONTINUATION ICONNECT TO EXISTING 4" LODCATION 3. LABEL NEW PIPING CO \ STR L CTI O OTES SEE SHEETS TNM138 AND 1M138 CW AT THIS APPROXIMATE CURRENT REVISION SHEET TNM502 JOB NO. DWG NO. COTES SCE DRAWI \GS AUG 1 0 2008 SYMBOL A r;r • 9 -101— TNM502 JAN 2 4 20UU DATE 11/26/07 COMP NO.