Loading...
HomeMy WebLinkAboutPermit PG08-031 - WESTFIELD SOUTHCENTER MALL - IVARS SEAFOOD BARIVARS SEAFOOD BAR 2600 SOUTHCENTER MALL FC -12 PGO8-031 Parcel No.: 6364200010 Address: Suite No: City Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PLUMBING /GAS PIPING PERMIT 2600 SOUTHCENTER MALL TUKW Permit Number: Issue Date: Permit Expires On: PG08 -031 05/23/2008 11/19/2008 Tenant: Name: Address: Owner: Name: Address: IVARS SEAFOOD BAR 2600 SOUTHCENTERMALL FC -12 , TUKWILA WA WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA Contact Person: Name: JOSEPH RYDMAN Address: 2106 PACIFIC AVE #300 , TACOMA WA Contractor: Name: LAKERIDGE PLUMBING & MECH Address: 13508 NE 124 ST , KIRKLAND Contractor License No: LAKERPM099RK Phone: Phone: 253- 627 -4367 Phone: Expiration Date: 05/25/2008 DESCRIPTION OF WORK: TENANT IMPROVEMENT PLUMBING IN MALL FOR NEW RESTAURANT. WATER SUPPLY, WASTE AND VENTS, AND GAS PIPING Value of Plumbing /Gas Piping: Fees Collected: $55,000.00 $500.13 Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 FIXTURE TYPE AND OUANTITY Plumbing (cont.) 0 Building sewer and each trailer park sewer 0 0 Rain water system - per drain (inside bldg) 0 0 Water heater and/or vent 1 0 Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 0 grease interceptors 0 0 Repair or alteration of water piping and/or water 5 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 0 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 1 6 Medical gas piping (6 +) inlets /outlets 1 5 Gas Piping 0 Gas piping outlets (0 -5) 5 0 Gas piping outlets (6 +) 1 * *continued on next page ** doc: UPC -10/06 PG08 -031 Printed: 05 -23 -2008 City "Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: PGO8 -031 Issue Date: 05/23/2008 Permit Expires On: 11/19/2008 Permit Center Authorized Signature: Date: 001,-40i I hereby certify that I have read and exnd this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied wi hether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this plumbing /gas piping permit. Signature:/ Date: ,43/co Print Name: /)+4y/2471,.+ 1 This permit shall become null void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -10/06 PG08 -031 Printed: 05 -23 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS 2600 SOUTHCENTER MALL TUKW IVARS SEAFOOD BAR Permit Number: Status: Applied Date: Issue Date: PG08 -031 ISSUED 02/06/2008 05/23/2008 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. * *continued on next page ** doc: Cond -10/06 PG08 -031 Printed: 05-23 -2008 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: v —` Date: Print Name: /0.41y/ dcf doc: Cond -10/06 PG08 -031 Printed: 05-23 -2008 CITY OF TUKWILA Community Development Department Public World Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hl"!p: /AI' w.cLItrku'ilu:u'a.irs Foi'.'O�f eillse onl Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.:_ l>7 l (9 ` LD j O Site Address :2bW %A-A(-041W- !AMA- --5714.+)u41 1hl19'S Suite Number: 12- Floor: 2- Tenant Nance: ‘IAA- `"E p 1776(g. Property Owners Name Mailing Address: C22 o AC...tei'VOL 1FAAV 1* fL `2- New Tenant: Yes ❑..No \LA City AState �$A:v Zip ont ct`wleny Day Telephone: Z - 627 - 1436 7 city State Zip Fax Number: Z ' 1Z1 - '13°(5 Name: ,ZjY�A - .j £RNA V(Vt Mailing Address: 0‘, b4 ' ice -Me. 4* SOD E -Mail Address: �1��4 �1ZA'PEf�►�. Go►1 Company Name: Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: City Day Telephone: Fax Number: Expiration Date: State Zip A; F FN., ,. Company Name: Mailing Address: 2- t?1, L 40t- t* Soo 437:A.41 Contact Person: dg£-51-- E -Mail Address: +rjd45 s ,E. ,r.RAy�s1/II•GoM Company Name: I Rtes or0% City Day Telephone: 2S' a - hZ1- ,'q 1 Fax Number: 273 - 621- ` '595 State Zip GNG.tic KS Mailing Address: _ 1701- 5 42"= Contact Person: 'Ruc. Gus- rxesO^v E -Mail Address: b33e l f'e -West Coen 3oi Q:Nppliaa timn\Forms- Applications On Line' -2006 - Permit Application.doc Revised' 9-2006 bh TAr o1A WA k$40? City Stale Zip Day Telephone: 453_-'14-v 3z eV Fax Number: s-5-3 - L1 _ 3`!(03 Page 1 of 6 PLUMBING AND GAS PIPING PERMIT INFORMATIO PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: - Mailing Address: City Stale Zip Contact Person: Day Telephone: E -Mail Address:_ Fax Number: Contractor Registration Number: Expiration Date: Valuation of Plumbing work (contractor's bid price): $— l Off. - Valuation of Gas Piping work (contractor's bid price): $ tO (GD 0 Scope of Work (please provide detailed information): T�,vAAPT TMPR.Oh/E -I /'r PWMBtA/4 W /4At� log 4/6Yt/ P- e5-rAv LAS✓ -T• Cul wAs-re. ( / IV1 AND GAS Govm'EC--rro.�s1.4tat,vs Age Pr- oviDeP lay rlgw, Building Use (per Int'I Building Code): - Occupancy (per Int'I Building Code): Utility Purveyor: Water: Sewer: - ndicate type of plumbing fixtures and /or gas piping outlets being installed and the quantity below: °Fixtile.e Tynei : Qty 1.i iure Type:: : ' --, Qty: Flzture Type Qty: - 'Fixtui a Type Q(Y Bathtub or combination bath/shower Drinking fountain or water cooler (per head) __ Wash fountain _ Gas piping outlets - _ — Bidet Food -waste grinder, commercial Receptor, indirect waste / f0 Clothes washer, domestic Floor drain , S Sinks - $ - _ Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer sewer _ Rain water system = per drain (inside building) Water heater and/or vent ' Additional medical gas inlets/outlets - six or more park _ _ Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type interceptors Repair or alteration of water piping and/or water treating equipment % Repair or alteration of drainage or vent piping ' Medical gas piping system serving one to five inlets/outlets for specific gas grease C \Applications\ Form - Applications On LineU -2006 - P ,mit Application doe Reeised. 9 -2006 bh Page 5 or6 Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expii ation of Plnn Review— Applications for which no permit is.issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be -requested in writing and justifiable cause demonstrated. Section 1014.3 Uniform Plumbing Code (current edition), I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY 13Y THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING E A TH(ORIZED AGENT: �� Signature: OR !) 1 o / R` a Date. b Print Name: -{' C ?pelt oN Day Telephone: 2 ene 7 - Mailing Address: __Plea i,6 \ M;t4 City Suite Zip Date Application Accepted: _A U Date Application Expires: Staff Initials: Q:Npp6eolions\Forms- Applisaliom On Line\ -2006 - Peisois Applicetion.dae Revised: 9 -2006 hh Page 6 of 6 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: PG08 -031 Address: 2600 SOUTHCENTER MALL TUICW Status: APPROVED Suite No: Applied Date: 02/06/2008 Applicant: IVARS SEAFOOD BAR Issue Date: Receipt No.: R08 -00921 Payment Amount: $407.30 Initials: WER Payment Date: 03/26/2008 02:42 PM User ID: 1655 Balance: $0.00 Payee: IVARS INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 195184 407.30 ACCOUNT ITEM LIST: Description Account Code Current Pmts GAS - NONRES PLUMBING - NONRES 000.322.103.00.0 99.30 000.322.103.00.0 308.00 Total: $407.30 0144 63/25 X711 TOTAL 1664.55 <A2 doc: Receiot -06 Printed: 03 -26 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: PG08 -031 Address: 2600 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 02/06/2008 Applicant: IVARS SEAFOOD BAR Issue Date: Receipt No.: R08 -00338 Payment Amount: $92.83 Initials: WER Payment Date: 02/06/2008 03:10 PM User ID: 1655 Balance: $407.30 Payee: IVARS INC TRANSACTION LIST: Type Method Description Amount Payment Check 194245 92.83 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000/345.830 92.83 Total: $92.83 8164 02/06 9710 TOTAL 448.58 doc: Receiot -06 Printed: 02 -06 -2008 INSPECTION NO. INSPECTION RECORD Retain a copy with permit r�dY> d3/ PERMIT NO. ti CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Proj ‹.....C°44 OZ Type f Iras ectio : g Address : be ,9/ f / Date Called: ��r0�!% Special Instructions: Date Wanted: 7 - /9 -o%° p.m. Requester: Phone No G -e /-2-435' 7 Approved per applicable codes. Corrections required prior to approval. COMMENTS: f ? /h f Cos- pit r c,/ ��r0�!% rar Cvnh «f» ®■ 7- 6N55 v:eG 7 r f t ■ Inspector: Date: (5 ri $60.00 RE SECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit PERMIT NO. (206)431 =3670 Project: Type of Inspection: Address: Sao rC �2- Date Called: Special Instructions: Date Wanted: 7� /� / � p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: nom/ cv O /e /e Inspector: Date: .7/ Ar° ri $60.0 INSPECTION FEE REQUIRED. Prior to inspection, fee must be paid 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: ti INSPECTION RECORD - Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION te- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 P6o)- -ail Project: / ia/ Type of Inspection: Address: A00 ill 411 Date Called: Special Instructions: Date Wanted: JJ,4 f p.m. Requester: Phone No: ElApproved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: •p. Ceim Inspector: Date: ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: a.,,�_.. sc.,e.eaw ■Ambah0q-. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 9- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 h Project: Type of Inspection: in 5,4 > eci .ek leA-i n /, e Address: �� 'AA _ 't � Y�� Date Called: 4^ A s ■ Special Instructions: Date Wanted;/ D , p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: in 5,4 > eci .ek leA-i n /, e 2 LLI' • j./7514/ 5lc//J l4fr", oai2 ,, •1L 7.5 4-74 /e 4^ A s ■ rear: 9 $6 REIN$RECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: 7/9 Receipt No.: Date: 3 INSPECTION RECORD Retain a copy with permit 4oesi INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. RM (206)431 -3670 Project;— L ///% S /J 4� Type Inspection: —J/t. l �_ Address: d,'/ ,i2.62/1 inh Date Called: Special Instructions: Date Wanted: m� Requester: Phone No: :3(7 —6 / EDApproved per applicable codes. Corrections required prior to approval. 1/ COMMENTS: PA_ L a PrL,s4., 0 h y Inspector: i� Date: fl $58.00 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: 2 NSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO.` CITY OF TUKWILA BUILDING DIVISION R-. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 I tif -113/ Project: �/91'S d Typ f Inspection:, /� ,( L /hi 4 ` %i% 4"`� /lI'i J Address: 26od /774-// Date Called: Special Instructions: Date Wanted: -- Z Requester: P6 — a 735-/ Approved per applicable codes. Corrections required prior to approval. COMM TS: S P / /.t L .•,eav -• 1.,�. Inspector: Date;, n ❑ $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: :1 1 INSPECTION NO. INSPECTION RECORD Retain a copy with permit o9)-6 PERMIT CITY OF TUKWILA BUILDING - DIVISION M 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (266)431 -3670 Pr, _- j6 T e o Inspe lion f Se� Address: 7J YnA-(1 Date Called. • 1 ~ Special Instructions: Date Wanted: —2.6`C P.m. Requester: ee No: Phone ! _-j (er f i—,`-C3 t � Approved per applicable codes. Corrections required prior to approval. COMMENTS: p/44_ Inspector Date: 5/2V/0 $58. EINSPECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: . _ ..�V .'}L�.i wSYYSL.�C�a�' BACKFLOW PREVENTION ASSEMBLY TEST REPORT CERTIFIED BACKFLOW ASSEMBLY TESTING WA. ST. CONT. LIC. # CERTIBA982M2 253- 565 -2728 OFC 888 -718 -0500 TOLL FREE r03 -(,jl SPEC. PLNB. LIC. # FREDEPE980P1 ACCT / FILE# METER # _ _ PERMIT#: PGO8 -031 PREMISE: IVARS COMMERCIAL © RESIDENTIAL 0 SERVICE ADDDRESS: 2600 SOUTHCENTER MALL #TC -12 CITY: TUKWILA ZIP 98188 CONTACT PERSON: ASSY. LOCATION: HAZARD TYPE: _ NEW INSTALL: PHONE: INSIDE COUNTER UNDER COFFEE BOILER COFFEE BOILER EXISTING: ❑ REPLACED: ❑ OLD SN#: FAX: DCVA ❑ RPBA © PVBA ❑ SVBA ❑ DCDA ❑ PROPER INSTALL: YES © NO ❑ MAKE ASSY: WATTS MODEL: 009QT __ SER. NO: A255779 _ SIZE: 0.5 INITIAL TEST DCVA / RPBA CHECK VALVE LEAKED CLOSED TIGHT _ 8.9 #1 ❑ DCVA / RPBA CHECK VALVE LEAKED CLOSED TIGHT #2 ❑ RPBA RELIEF VALVE OPENED: 4.2 PSID PVBA / SVBA AIR INLET OPENED: PSID ❑ PASSED X FAILED TO OPEN: AIR GAP: OK? ❑ FAILED ❑ X )( FAILED TO OPEN: PSID PSC X NEW PARTS AND REPAIRS CLEAN / REPLACE PART CLEAN / REPLACE PART CLEAN / REPLACE PART PVBA /SVBA CHECK HELD AT: PSID ❑ ❑ ❑ ❑ ❑ ❑ LEAKED ❑ ❑ ❑ ❑ ❑ ❑ ❑ CLEANED ❑ REPAIRED ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ TEST AFTER REPAIRS PASSED ❑ FAILED ❑ LEAKED CLOSED TIGHT ❑ ❑ PSID LEAKED CLOSED TIGHT ❑ ❑ PSID OPENED AT: PSID AIR INLET: PSID CHK VALVE: PSID AIR GAP INSPECTION: SUPPLY PIPE DIAMETER " SEPARATION: " PASS FAIL ❑ WATER FOUN FF DETECTOR METER READING: LINE PRESSURE: 70 e used WAC 248 - 290490 approved methods and test equipment. TESTER SIGNATURE: % . . ���Lt����� ��� CERT. NO.: B3415 DATE 11 JULY 08 PRINTED NAME: PAUL E. FREDERIC TEL. NO.: ( 253) 565 -2728 REPAIRED BY: PAUL E. FREDERICK CERT. NO.: FREDEPE980P1 DATE: FINAL TEST BY: CERT. NO.: B3415 DATE: METER CAL DATE: 7 SEPT 07 MAKE /MODEL: _ MIDWEST 830 METER SERIAL NO: 330247 PERMIT COORD COPY • PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: PG08 -031 DATE: 02 -06 -08 PROJECT NAME: IVAR'S SEAFOOD BAR SITE ADDRESS: 2600 SOUTHCENTER MALL FC -12 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: t7 L Thm, 2-I� Building Division Fire Prevention n Planning Division P�pL- Work$ 'L- -op Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 02 -07 -08 Permit Coordinator Complete Comments: Incomplete n Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: d DUE DATE: 03-06 -08 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Look Up a Contractor, Electric or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. License Information License LAKERPM099RK Licensee Name LAKERIDGE PLUMBING & MECH INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601349575 Ind. Ins. Account Id 48691501 Business Type CORPORATION Address 1 13508 NE 124TH ST Address 2 City KIRKLAND County KING State WA Zip 98034 Phone 4258279262 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 12/12/1991 Expiration Date 5/25/2010 Suspend Date Separation Date Parent Company Previous License LAKERPM 132OP Next License EVERGPM066LA Associated License Business Owner Information Name Role Effective Date Expiration Date GLENNON, JOHN P Cancel Date 01/01/1980 Bond Amount GLENNON, ANNE K #6 01/01/1980 SC7509 • Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #6 CBIC SC7509 05/25/2002 Until Cancelled 512,000.00 04/30/2002 #5 CBIC SC7509 05/25/2000 05/25/2002 56,000.00 07/18/2001 Page 1 of 2 httpsJ/ fortress. wa. gov /lni/bbip /printer.aspx ?License= LAKERPM099RK 05/23/2008 KITCHEN EQUIPMENT SCWWIDULE SYMBOL FIXTURE MANUFACTURER MODEL PLUMBING CONNECTIONS (IN) -- MOUNTING NOTES WASTE INDW VENT GAS HW CW BTU El REFRIGERATED, FOOD PREP TABLE TRUE TSSU- 60 -16D -4 - - - - - - --- - 1 E2 POS RADIANT SYSTEMS P1510 POS --- - - - - - - - 1 E3 RECEIPT PRINTER & CASH DRAWER RADIANT SYSTEMS EPSON TM- T88111 - - - - - - - - 1 E4 ICE BIN DELFIELD N8030 - 1" --- - - - - -- - 1 E5 4 SOUP WARMERS IN CUSTOM SOUP STAND WELLS & CUSTOM SW -10T & TBD - - - -- - -- - 1 E6 ICE /BEVERAGE DISPENSER LANCER ICD 2300 - 3/4" - - - - - --- 1 E7 REFRIGERATOR, UC, LOW PROFILE TRUE FOOD SERVICE 2 DOOR #TUC -36 -LP - - - - - - - - . 1 E8 AIRPOTS CURTIS THERMOPRO TLXA2201G000 - - - - - - - - 1 E9 COFFEE MACHINE CURTIS WILBUR SERIES- #D500GTH12A000 -- - - - - 1/4" - - 1 El0 HAND SINK ADVANCE TABCO DI -1 -10 2" - 1 -1/2" - --- 1/2" 1/2" - COUNTER 1 Ell WIRE SHELVING INTERMETRO INDUSTRIES VARIES, VERIFY - - - - - - - 1 E12 REACH -IN REFRIGERATOR TRAULSEN 020010 - - - - - - - - 1 E13 DEEP FAT GAS FRYER PITCO SG14-S - - - 3/4" - - 10,000 - 1 E14 CLASS 1 EXHAUST HOOD CAPTIVAIR 4824ND- 2- PSP -FSS -8 - -- - - - - - - 1 El 5A CHAR -- BROILER STAR -MAX 6124RCBD - - -- 3/4" - - 80,000 - 1 E15B FLAT TOP GRILL STAR-MAX 624TD - - - 3/4" - - 40,000 - 1 E16 WALL SHELVING ITERMETRO INDUSTRIES VARIES, VERIFY - - - - - - - - 1 E17 REACH -IN FREEZER TRAULSEN G12001 --- - - - - - - - 1 E18 FAT /OIL FILTER R.F. HUNTER CO HF -80 -- - - - - -- - - 1 E19 BREADING SYSTEM HENNY PENNY HB- 121.02 - - --- - - - -- - 1 E20 MOP SINK SSP, INC. FLR -1 -X 3" - 2" - 1 /2" 1/2" - FLOOR 1 E21 ICE MAKER MANITOWOC SY -0504A - 1 /2" - - - 3/8" - -- 1 E22 CUSTOM COMBO: FRZ /REF NORLAKE WALK-IN CUSTOM -- - - - - - - - 1 E23 CO2 CANISTERS BY VENDOR TBD- UNDERCOUNTED - - - - - - - - 1 E24 3 COMP SINK SSP, INC. SL3C1723-2-18 2" - 1-1/2" - - 1/2" 1/2" - COUNTER 1 E25 PREP SINK SSP, INC. SL1 01723- L---24 - 2" -- 1/2" 1/2" - COUNTER 1 E26 WORK TABLE SSP, INC. SLWT24S6OSTS - - - - - - - - 1 E27 CONVECTION STEAMER CLEVELAND RANGE GEMINI 10 24 -CGA -10.2 - 1 -1/2" - - 3/4" - (2)1/4" 144,000 - 1 E28 EXHAUST HOOD CAPTIVAIR CLASS 2 - 4224VHB --G- PSP -F--ND - - - - - - - 1 E29 MANAGER'S DESK & CHAIR BY OWNER BY OWNER - - - 1-1/2" - - - - - 1 E30 HAND SINK ADVANCE TABCO 7 -PS -60 2" - - 1/2" 1/2" - WALL 1 E31 SAFE TBD --- - - - - -- - -- - 1 E32 WORK TABLE SSP, INC. 15 "X34" CUSTOM WORK TABLE - - - 1 -1/2" - - - - - 1 E33 HAND SINK ADVANCE TABCO 7 -PS -60 2" - - 1/2" 1/2" - WALL 1 NOTES: 1. FURNISHED BY OWNER, INSTALLED BY CONTRACTOR. MEC1-- I4NICAL LEGEND SYMBOL DESCRIPTION MANUFACTURER COLD WATER PIPING PLUMBING CONNECTIONS (IN) -- WEIGHT (LBS) HOT WATER PIPING WASTE INDW WASTE PIPING HW --- - - - --- VENT PIPING FLOOR DRAIN GAS PIPING 0 2" GREASE WASTE 1 -1/2" - PIPE DOWN c PIPE UP 0 FUNNEL FLOOR DRAIN 1 BRANCH - TOP CONNECTION 2" - 1 BRANCH - BOTTOM CONNECTION - FLOOR BRANCH - SIDE CONNECTION FS 3 "FCO FLUSH CLEANOUT OR SURFACE CLEANOUT a 2" FLOOR DRAIN 1 -1/2 " 0 -- -•- DRAIN VALVE W/ HOSE BIBB fi4 NOTES: CHECK VALVE l UNION 4 METER M 0 POINT OF CONNECTION TO EXISTING Q TEMPERATURE GAUGE TEMPERATURE & PRESSURE RELIEF VALVE -----6 BALL VALVE PLUMBING FIXTURE SCHEDULE SYMBOL FIXTURE MANUFACTURER MODEL PLUMBING CONNECTIONS (IN) MOUNTING WEIGHT (LBS) NOTES WASTE INDW VENT HW CW FD FLOOR DRAIN J.R. SMITH MODEL 2005Y -B-- -U 2" - 1 -1/2" - - FLOOR FFD FUNNEL FLOOR DRAIN J.R. SMITH MODEL 3510Y -F11 -U 2" - 1 -1/2" -- - FLOOR FS FLOOR SINK J.R. SMITH MODEL 3101Y -42 -C 2" - 1 -1/2 " - -- FLOOR NOTES: ELECTRIC WATER HEATER SCHEDULE SYMBOL WH - 1 MANUFACTURER BRADFORD WHITE MODEL M - 11 - 80 CAPACITY (GAL) 80 DISCHARGE TEMP (DEG F) 120 RECOVERY GPH 136.52 TEMP RISE 90 ELECTRICAL VOLT 480 PHASE 3 KW 30 WEIGHT (LBS) 335 NOTES NOTES: EXPANSION TANK SCHEDULE 7ULE SYMBOL MANUFACTURER ET - 1 AMTROL MODEL ST - 12 TYPE DIAPHRAGM CONFIGURATION VERTICAL PRESSURE (PSI) — 70 VOLUME (GAL) TOTAL 4.4 ACCEPTANCE 0.45 WEIGHT (LBS) 9 NOTES NOTES: GENERAL L NOTE S 1. LOCATE ALL VALVES, TEST PORTS, ETC., TO BE ACCESSIBLE FOR MAINTENANCE, ADJUSTMENT, & TESTING. PROVIDE ACCESS PANELS FOR ALL CONCEALED DEVICES. 2. INSULATE PIPING PER WASHINGTON STATE NON- RESIDENTIAL ENERGY CODE REQUIREMENTS. S'EP'ARATE Pt rail I 1 REQUIRED FOR: . M DrEjectricul 0 Piu'nOsng 0 Gas Piping City of Tuik i a g l N!G _214RC -ice yfi (E) BTU CW DEG DN F FFD FCO FD FS GAL GPH GPM GR HP HW IN INDW IPLV KW LBS MIN PD PSI SCO TYP UPC V W 4IBIBRE V 14T I QN LIST DEGREES FAHRENHEIT EXISTING BRITISH THERMAL UNIT COLD WATER DEGREE (FAHRENHEIT) DOWN FAHRENHEIT FLOOR & FUNNEL DRAIN FLUSH CLEANOUT FLOOR DRAIN FLOOR SINK GALLON GALLONS PER HOUR GALLONS PER MINUTE GREASE WASTE HORSEPOWER HOT WATER INCH INDIRECT WASTE INTEGRATED PART LOAD VALUE KILOWATT POUNDS MINIMUM PRESSURE DROP POUNDS PER SQUARE INCH SURFACE CLEANOUT TYPICAL UNIFORM PLUMBING CODE VENT WASTE FILE COPY Permit No. . Piar review approval is subject to errors and omissions. Approval of construction docurnents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is edged: By Date:, / ; //' City of Tukwila BUILDING DIVISION i RECEIVE r FEB - 6 2008 PERMIT ':r' I cs F&OgO31 0 0 z cn z P 11:a44 L) c = 1 — �a Q m E & Z 121 U P0.1 • • • • CM a ce • • CD 3 0 . (E)4" GREASE WASTE (E)4 "W 12" UP P3.0 J TO SCO 1 -1/2 "V UP 2 "GR U TO FFD (E)4" GREASE WASTE 1 4 "' g mk,- r 1 1 1 1 iiiMMii -- :_ate: gism r- E^--•w .Err �ww I _- - - li ca -al 'r Him nu MN L TO PD nt 111111 IIL -� -- == = == 1111111111111111III = =- / 2 "W UP I - r - "WI 3 "GR 1 - 1/ 2 "V UP II L ▪ I y -1 2 "W UP / 1- 1/2 "1 / I S A R EA GR IIV 11 �1 DD _ - 1 -1 /2 "V O F D \ t1 y �= 1111 \ \` 1y 11 G � 1 1 , 1 w 11 L��~ J ■ "R UP tl _ _ 1 I ! 2" UP 1 _ TO FD 3 "GR .1 g i d �} _,I GR � GR ' \- 2 "GR 3 " GR ,. U� l X112 "GR UP r TO1SCO \ _ _ —� TO :IS _ � � 1 _ _ - � — -� � '/ � 1 _ ~ \! ��; 11� 1 11 1 1 f '- -- —_ — 11 4"W TO S IIIIIIIIIIII 111111111111 IIIIII111 II ElIi ,....■ ■111111! III (E)4" GREASE WASTE >- L . L I C ) Q2" -� -71I ■ GR U TO FS I_ , r' 2 "GR - - 1 3 "GR 3 G 3 "GR 3 "GR 1 GR GR GR GR GR 1 TO SCO 3 "W ` 1 -1 /2"V 3 "W 3 "W UP 3 "GR UM TO SCO _ TO SCOJ 2 "GR UP I PREP • 102 2 "GR UP TO FFD cz TO ED 2 "GR UP 1:11t 1 cp 1 TO FS I I ' I � , ,m 11 I {3 "GR I I i 1111 1-1/2"V U FE 1 -1/2 "V UP 2 "GR UP TO SCO 2" UP 2" UP 1 -1/2 "V 2" UP TO FD 2" UP TO SCO FLUM5INC FLAN - 2Nr) FLOOR FOUNDATION SCALE: 3/S " =1' -0" 0 1' 2' 4' RECEIVE` FEB -6 zoos PERMIT CENT& P1.0 • r a a CD i r 1 • • 1 r O ts 9rrrrarnk`rrunlrrrnrnrnr rrw r rr araar 1111(1111 ,M5 111 � rnllnnrx] 111,_11 ► mum R1111:III!il11 ° ill1111111111nnull1111111111 -w MET .1.- :l lrrrarrrrl r rrrr�rrrrRrgRr rrrrrs -1111 • AIRr.- , 41=1= r, — -.1 11 —r -- -a.- 1 — _ _ . I1 —.1 -- FS 13 rw1I - Ia- -IIwwN1.. ._. -. 11. G- la■ MIN . I.RIBMIIRRRRRIIIRL.. — iI m 1111i111111I111I11111 _ ` -1.111 — r 110011111111111111 „ �, x;11 1i:1i11111111g111111 Rear: arrrunrra�,RrrRrrr.re. •,� .r1 M 0 J r '/7777/r 7T ' 1 -1/2 "V I li 1 -1/2 "V i - -�' i — J1 1 -1/2" 11 - r -- r h� /- 11 i FFD 1 -1 /2 "V 0 / 1 GD (E)3" VENT (E)2" CW (E)2” GAS L _J [ ■I ,2" • L Wz J 1 0 1 111 1,11 ; 1111 11 {I 1 11 1 u• / cc of A ai MEMEMINIFIMEMMI 7 -4 2 "V 3/4" �- 3/4" zeirdter 1/2" 1 -1/2 "V _ It /2" 3;/4" PREP 102 j G / A P" / - -�-NII■ 1, 0 co FS Off G FD 3 / '. AIL :IriR RRRrR rnn rrl uRiARaRi ■ 111111 .1111111111111111111111111111 1111 IR '!!ii1�1111111111111 11111 CI 111111111 N I11111111 main uInIRRRnnnnnn 1mum jo r I 05 00 ess 2 L G X> (E)3/4 1-1/2"v ET--1 WH -1 1 -1/2 "V 1 -1/2 "V 1/2 1 ( !,— 2--1 /2 "V f WATER METER 5a \ (TYP. 1 -1/2" t 1 / , 1 i -- - J FD L_� ' !" 2” J 3/4" 3/4" 2 1 /2" \`‘,7,/,' X• 2 "V t L T G 0 FD FS r _3,4" 1 1 -1/2" 1 FE /2 "V FS 1 -1 /2 "V 1 /2" 2 "V 1--1 /2 "V " SCALE: 3/8 II -0 �_ra ■rrnrrrrr . rr 0 1' 2' 4' 1 /2" 1 -1 /2 "V 1 /2" • 1 /2" L 3/4" 1 -1 /2 "V 0 FD r 1 /2" 12X20 12X20 ;HOTEL HOTEL SERVICE AREA 4 \ 1 100 l ` 11 11 ; 11 1 1 /2" 1 -1/2 "V 1 /2" 1 -1 /2 "V 1 /2" (TYP.) PLUMIBING FLAN - 2NE7 FLOOR -JL 3 /4" 1 -1 /2 "V " 1 3 / 4 " J - 1 -- --- --I KITCHEN IND r 101 7/ / / 1 r i i f 1 i 1 1 1 1 1 1 r J r GENERAL NOTES 1. NOTE 1 FLAN NOTES O PROVIDE GAS PRESSURE REGULATOR WITH VENT LIMITING DEVICE. a INDIRECT WASTE TO FLOOR DRAIN. O INSTALL WATER HEATER ON PLATFORM ABOVE WALK -IN COOLER. REFER TO ARCHITECTURAL DRAWINGS FOR PLATFORM. • 1 /2 "CW DOWN. REDUCE TO 3/8" AT COFFEE MACHINE. Q PROVIDE ACCESS PANEL IN CEILING. FEB -6 2008 PERMIT CE TEh r O r � F+1 0 z 01 3 DO a1 0 o csi N O 1`7 0 1 7 F PT-1 w oa w 1 E•4 0 z w � W I E E1Cn B .e4 Po U P1.1 • 0 U Z 0 m • • • 0 0 0 O • • g- w 0 i N 0 NEI v CD 1 -1/2" THIRD FLOOR _ J 2-1/2" 2" 1 -1 /2" 2" 1-1/2" 2" 1 -1 /2" 1-1/2" " T Z �� _ f EXISTING 3 VENT L_ �1� - - ----- - 1 -1/2 "_ [ _1� 1_ -c' 2"4_ -7?- 1 -1/2 " - 2:11 Z r _ .._ r ._.. —_. CEILING SECOND FLOOR EXISTING 4" WASTE 3 "W 4 "W CEILING 2 "W 2 "W R CV (2 FU) E33 2 "W - " 3"W (2 FU) 100 El 0 V 0 J 2w -� (2 FU) 0 0 102 E3 ' 0 n V 2 "W 1 3 "W N (3 FU) E20 3 "W V) V) K) ih EXISTING 4" GREASE WASTE 1 -1/2" 1 -1 " - /2 1 1 /2 " 4 "GR GR 1 - 1 / 2" 1 -1/2" 2" SCR 2 "GR (2 FU) FD e- <3 --- -- 1 - - � 1 -1 /2" - -? ? �-__ _� -- - -- — r 1 -1/2" I 1 i (2 FU) (2 FU) 102 10' FFD FD (2 FU) 100 FD 1 T r - - - (2 FU) FS WASTE RISER ED IAGRAM SCALE: NONE (2 FU) FD (2 FU) 100 FS v r7r-r- 2"GR 2 "GR 2 "GR 2 "GR GR GR GR GR GR GR GR GR GR GR GR 3"GR 3 "GR 3 "GR GR GR 0 0 (1) GR 2 FU) 102 FD 1 1 GR GR (2 FU) 102 FS 2 "GR GR 3 "GR (2 FU) 102 FS I n 2 T (2 FU) 2 "GR 2 "GR / GR-- -/ GR (2 FU) E24 E24 LT' I L �-- 2 "GR 2 "GR GR GR (2 FU) 102 E24 0 2 G / v b\-- lV 2 '1M 2'1M GR GR GR GR GR GR 3 "GR GR GR 2 FU) (2 FU) FS GR 3 "GR 0 0 0 0 4) RECRVEri FEB - 6 2008 PERMIT CENTEh PI w W N 1x L E ., Q z E . H U Z 0 x h pa pc) UT P2.0 • • • • • 8 CD REMOVE AND STORE STRAINER, STRAINER HEAD AND FLASHING COLLAR DUCT TAPE CONCRETE BY GC DURING CONCRETE POUR (STEP #1) FLOOR DRAIN INSTALLATION DETAIL SCALE: NONE PIPE HANGER GALVANIZED METAL SHIELD BETWEEN HANGER & INSULATION UP TO CENTERLINE OF PIPE PIPE INSULATION CUT 1 --1/2" RIGID INSULATION TO FIT. ATTACH WITH DUCT TAPE VAPOR BARRIER (TYP) FLOOR DRAIN BODY NQTE: COMPLETE INSTALLATION OF FLOOR DRAIN AND SETTING OF FINAL ELEVATION SHALL NOT BE ALLOWED DURING INITIAL CONCRETE POUR INSTALL STRAINER, STRAINER HEAD, & FLASHING COLLAR (SEE FINAL ELEVATION) FLOOR DRAIN BODY CONCRETE BY GC STRAINER HEAD STRAINER THREADED ROD; ATTACH TO STRUCTURE RIGID INSULATION PIPE INSULATION PIPE 1 \ \ : /\\ \ \ 6" MIN,k 10" MIN INSULATED PIPE HANGER DETAIL SCALE: "" FINISHED GROUT FLASHING COLLAR AFTER CONCRETE HARDENS (STEP #2) CW SUPPLY EXPANSION TANK ET -1 CATCH PAN TOP OF PLATFORM INSULATING PAD (SEE SPECIFICATIONS) SCALE: ar" PIPE HANGER 1 HW TO FIXTURES PI PE 3/4" TO INDIRECT CONNECTION AT PLUMBING FIXTURE IN SPACE BELOW PROVIDE DRAIN VALVE ON WATER HEATER OR LOW POINT OF PIPING 1" TO INDIRECT CONNECTION AT PLUMBING FIXTURE IN SPACE BELOW ELECTRIC WATER HEATER DETAIL THREADED ROD; ATTACH TO STRUCTURE GALVANIZED PIPE SHIELD TO PROTECT PLASTIC PIPING FIFE SUPPORT DETAIL SCALE: "r" NOTE: WATER HEATERS SHALL HAVE SEISMIC SUPPORTS ATTACHED TO STRUCTURE. BRONZE TOP SURFACE CLEANOUT DETAIL. SCALE: 4 *" FINISHED FLOOR, SLAB, OR GRADE RISER PIPE WASTE PIPE RECERTT FEB o 6 2008 PERMIT CENTEF, 0 a z Cn H w 1 MUM P3.0 • 2 0 U z C9 W 0 m • ■ 8 CD