HomeMy WebLinkAboutPermit PG08-033 - WESTFIELD SOUTHCENTER MALL - LOVE CULTURELOVE CULTURE
1006 SOUTHCENTER MALL
PGO8-03 3
Parcel No.: 6364200010
Address:
Suite No:
City Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
PLUMBING /GAS PIPING PERMIT
1006 SOUTHCENTER MALL TUKW
Permit Number:
Issue Date:
Permit Expires On:
PG08 -033
04/23/2008
10/20/2008
Tenant:
Name: LOVE CULTURE
Address: 1006 SOUTHCENTER MALL , TUKWILA WA
Owner:
Name: WEA SOUTHCENTER LLC
Address: 11601 WILSHIRE BLVD , LOS ANGELES CA
Contact Person:
Name: PAUL JAIME
Address: 2413 PACIFIC COAST HY #202 , LOMITA CA
Contractor:
Name: PLUMBING EXPRESS INC
Address: 813 ACADEMY ST , SUMNER WA
Contractor License No: PLUMBEI98600
Phone:
Phone: 310 606 -2078
Phone: 253 826 -4621
Expiration Date: 09/20/2008
DESCRIPTION OF WORK:
TENANT IMPROVEMENT: (1) FEMALE AND (1) MALE RESTROOM
Value of Plumbing /Gas Piping:
Fees Collected:
$8,800.00
$202.00
Plumbing
Bathtub or combination bath/shower - - -- -
Bidet
Clothes washer, domestic
Dental unit, cuspidor
Dishwasher, domestic, with independent drain
Drinking fountain or water cooler (per head)
Food -waste grinder, commercial
Floor drain
Shower, single head trap
Lavatory
Wash fountain
Receptor, indirect waste
Sinks --
Urinals
Water Closet
Uniform Plumbing Code Edition: 2006
International Fuel Gas Code Edition: 2006
FIXTURE TYPE AND QUANTITY
Plumbing (cont.)
0 Building sewer and each trailer park sewer 0
0 Rain water system - per drain (inside bldg) 0
0 Water heater and /or vent 1
0 Industrial waste treatment interceptor, including
0 its trap and vent, except for kitchen type
0 grease interceptors 0
0 Repair or alteration of water piping and/or water
2 treatment equipment 0
0 Repair or alteration of drainage or vent piping 0
2 Medical gas piping system serving (1 -5)
0 inlets /outlets for a specific gas 0
0 Medical gas piping (6 +) inlets /outlets 0
0 Gas Piping
0 Gas piping outlets (0 -5) 0
2 Gas piping outlets (6 +) 0
* *continued on next page **
doc: UPC -10/06
PG08 -033 Printed: 04 -23 -2008
City o4Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Permit Number: PG08 -033
Issue Date: 04/23/2008
Permit Expires On: 10/20/2008
Permit Center Authorized Signature:
oz,LL
Date: 1,)-3---10 8
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the • erformance of work. I am authorized to sign and obtain this plumbing /gas piping permit.
Signature:
Date: 1 23 -05?
Print Name: v�� gd l dG✓�_
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: UPC -10/06
PG08 -033 Printed: 04 -23 -2008
Parcel No.: 6364200010
Address:
Suite No:
Tenant:
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206- 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
PERMIT CONDITIONS
1006 SOUTHCENTER MALL TUKW
LOVE CULTURE
Permit Number:
Status:
Applied Date:
Issue Date:
PG08 -033
ISSUED
02/07/2008
04/23/2008
1: ** *PLUMBING AND GAS PIPING * **
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila
Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing
inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas
Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code.
Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to
make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless,
adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the
conditioned space shall be insulated to minimum R -3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be
protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing
piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in
accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to
twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill,
frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the
jurisdiction.
* *continued on next page **
doc: Cond -10/06
PG08 -033 Printed: 04 -23 -2008
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www:ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work
construction or the performance of work.
Signature: /1'_ Date: 4/-2-3-0C1/
Print Name: qt.) L- 1,1 44' C CSCV-P
ordinances governing
or local laws regulating
doc: Cond -10/06 PG08 -033
Printed: 04 -23 -2008
1
•
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
h://www.ci.tukwila.wa.us
1
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
site mate._ _ 00 Son-viCie-o-ivatANLA..
Tenant Name: Lehi kTuae
Property Owners Name: LO1 CA/ k.Tv as
King Co Assessor's Tax No.: (89-174-17/0 00(-0
61).
_S4itte" umber: iQCC Floor:
New Tenant:
Yes la .No
Mailing Address: -%t S6Te> STQEET
LcE, ..Act.iG a 6%
City
Name: \AL.,
Mailing Address: XL tAINiq *0_0
E-Mail Address: 120- ut sci c.
Company Name:
State
Day Telephone:, 3 t 0,1. 6 Oki' "<90-18
Lai1/44 it ik CA q CR II
City State Zip
Fax Number: 3(0 606 - al 1:7
Mailing Address:
Zip
Contact Person:
E-Mail Address: -
Contractor Registration Number:
Company Name: Ci5ta-A03-0 IW204%
City
Day Telephone:
Fax Number:
Expiration Date:
State
Mailing Address: .1 1 t'4 f IELDeR 0-0k9
6 pA urt-t
Contact Person:
M-Lt NICNTDt.‘
City
Day Telephone:
Fax Number:
E-Mail Address:
11, 1 Go
Zip
51) SCS -3'g1
tct-i Sq
Company Name: 141- L c
. .
Mailing Address: t s3t oPAA 7V- 4(Q State zip
Contact Person:
E-Mail Address:
Q: Applientionaorms,Annlications On Line13-2006 PiumitApplicationdOc
Revised: 9-2606
bh
50-vo ccAe (1 Day Telephone: Sr SbSO
Fax Number: g SC1 " U4 - O5 1
Page 1 of 6
PLUMBING AND GAS PIPING CONTRACTOR INFORMATION
Company Name:
Mailing Address:__ _
1
City State Zip
Contact Person: Day Telephone:
E-Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
Valuation of Plumbing work (contractor's bid price): $ iS 0
Valuation of Gas Piping work (contractor's bid price): $
Scope of Work (please prow
detailed information):
nickh cA• ill cutre---froom
Building Use (per Intl Building Code):
Occupancy (per Intl Building Code):
Utility Purveyor: Water: Sewer:
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
Q: Applicationaamv-Applientions On Line3-2006 - Permit Application.doe
Revived: 9-2006
bh
Page 5 of 6
..... ...
QtY
Bathtub or combination
bath/shower
Drinking fountain or water
cooler (per head)
Wash fountain
Gas piping outlets
Bidet
Food-waste grinder,
commercial
Receptor, indirect
waste
Clothes washer, domestic
Floor drain
,:
Sinks
Dental unit, cuspidor
Shower, single head trap
Urinals
Dishwasher, domestic,
with independent drain
Lavatory
3....
Water Closet
Building sewer or trailer
park sewer
Rain water system — per
drain (inside building)
Water heater and/or
vent
1
1
Additional medical gas
inlets/outlets — six or more
Industrial waste
pretreatment interceptor,
including its trap and vent,
except for kitchen type
grease interceptors
Repair or alteration a water
piping and/or water treating
equipment
Repair or alteration
of drainage or vent
piping
Medical gas piping system
serving one to five
inlets/outlets for specific gas
Q: Applicationaamv-Applientions On Line3-2006 - Permit Application.doe
Revived: 9-2006
bh
Page 5 of 6
• •
PERMIT APPLICATION NOTES -- Applicable to all permits >in;this application . .
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 1053.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
1 HEREBY CERTIFY THAT! HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING 0
Signature:
Print Nam
R AUT
ENT:
Date: o //3/�o U7
Mailing Address:
Day Telephone•
City
State
Zip
Date Application Accepted:
tj/j'J' fJ V I D
COIOld
Date Application Expires:
^1
(�
,�
r
Staff Initials:
Q:wppliestiomW®nrwpplicacon. On tim\3 2006 - Permit Applieation.doc
Raved: 9 -2006
bh
Page 6 of 6
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http. / /www.ci.tukwila.wa.us
SET RECEIPT
RECEIPT NO: R08 -00351
Initials: JEM
User ID: 1165
Payee: PERMITS DIRECT
Payment Date: 02/07/2008
Total Payment: 1,128.33
SET ID: S000000954 SET NAME: Tmp set/Initialized Activities
SET TRANSACTIONS:
Set Member Amount
D08 -076 834.86
EL08 -126 184.50
M08 -033 70.97
PG08 -033 38.00
TOTAL: 1,128.33
TRANSACTION LIST:
Type Method Description Amount
Payment Check 1220
ACCOUNT ITEM LIST:
Description
TOTAL:
1,128.33
1,128.33
Account Code Current Pmts
ELECTRICAL PLAN - NONRES
PLAN CHECK - NONRES
000.345.832.00.0 184.50
000/345.830 943.83
TOTAL: 1,128.33
9233 02/07 0710 TOTAL 1128°33
n,.,.• orrermv nc
INSPECTION RECORD p
Retain a copy with permit PGc8 -o3.3
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION I"
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 - 6
INSPECTION NO.
Project:
LGlECzA Hit vv
Type of inspection:
1- iki6AI
U
Address:
Date Called:
Special Instructions:
Date Wanted:
-7- z4-063
a.m.
p.m.
Requester:
Phone No:
Spproved per applicable codes. Corrections required prior to approval.
COMMENTS:
spec
r:
Date:
ri 60 00 REINSPECTION FETE REQUIRED. Prior to inspection, fee must be
p i at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION Ca'
Southcenter Blvd., Tukwila WA 98188 (206)431 -360
6300 Sout ,
p(d)8-63-3
Pro'ect:
1I e 0'..( �-{�� IrP
Type of Inspection:
}-- I Nil L— ?I ildWk I)
Address:
Date Called:
- -4,"P .5 /1i mid`
Special Instructions:
Date Wanted:
Requester:
Phone No:
jo -31-1-- )�
(3
ElApproved per applicable codes.
IgCorrections required prior to approval.
COMMENTS: - •
y!STS //
- -4,"P .5 /1i mid`
2a acc e 715
/ fV) res /IGO /u i'
Date:
24/01,9
'2
El $60.0 EINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid a 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Project,: n
c-cve. l Z_lt .,Cte
Type Inspection: t
(C� 6,— f iv
Address:
1 oOCO m4c(
Date Called:
Special Instructions:
Date Wanted:
— 8 - Q p.m.
Requester:
Phone No:
D- S? - ?c'_S- 182P'
Approved per applicable codes. Corrections required prior to approval.
COM M ENTS:p4
/(ice )7%, (7i fot....5 to 4Pia-4,,A e•k >
* tl °f'- (2I(V NJ- i"'si/la Pre- Vtsr- asg.e5
Inspector:
Date:
Ei $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection.
Receipt No.:
Date:
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION gr
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
r+
Project:
.LPig,7 /7/0-1.-
Type of spectio : -
R 11) /44 —i A/ A2/LeAp
Address 6,. / //
Date Called:
Special Instructions:
Date Wanted:
1_ 7 Q L O
m.
Requester:
Phone No:
-7,53 -25-5- /9Z/'
❑ Approved per applicable codes. LJ Corrections required prior to approval. 4
COMMENTS:?/fr
MLA/ wig
lAs/e0 fj
Inspector:
Date:
>elei
$58.0 EINSPECTION FEE REQUIRED. Prior o inspection, fee must be
pai
at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection.
Receipt No.:
Date:
INSPECTION RECORD \-)
a copy with permit P6O, 033
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Project: T
Type of Inspection:
Address: D
Date Called:
Special Instructions: D
Date Wanted: 6
6.m-
Requester:
--1 Po i\li TkiSietoti--Ohi
Phone No
p_.53-Zs -
- iR2p
Approved per applicable codes. Corrections required prior to approval.
CO'" ' ENTS:
pJ u 170%t If (3fte L
l��'-s
--1 Po i\li TkiSietoti--Ohi
z�v
e pox . . 5 40e r` - 0 €
i'ele
V /
r
I pecto
(kW? 1\11
L.
pa
.0
d
Dat — 2 Li-
REINSPECTION EE REQUIRE Q. Prior o inspection. fee must be
t 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection.
Receip No.:
Date:
• PERMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: PG08 -033 DATE: 02 -07 -08
PROJECT NAME: LOVE CULTURE
SITE ADDRESS: 1006 SOUTHCENTER MALL
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # After Permit Issued
DEPARTMENTS:
Atju 2q5 -0t)
Bui •iIg DWi"sion Cyj
Public Works
Dank 'U,&L. Avg
-og
Fire Prevention
Structural
n
Planning Division
Permit Coordinator
n
n
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete TVT Incomplete
Comments:
n
DUE DATE: 02-12-08
Not Applicable
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROU ING:
Please Route Structural Review Required
REVIEWER'S INITIALS:
nNo further Review Required
DATE:
APPROVALS OR CORRECTIONS:
Approved ❑ Approved with Conditions
Notation:
REVIEWER'S INITIALS:
DUE DATE: 03-1 1 -08
Not Approved (attach comments) n
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
Look Up a Contractor, Electrician or Plumber License Detail
•
Washington State Department of Labor and Industries
General/Specialty Contractor
A business registered as a construction contractor with L &I to perform
construction work within the scope of its specialty. A General or Specialty
construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
License Information
License
PLUMBEI98600
Licensee Name
PLUMBING EXPRESS INC
Licensee Type
CONSTRUCTION CONTRACTOR
UBI
602226682
Ind. Ins. Account Id
VICE PRESIDENT
Business Type
CORPORATION
Address 1
813 ACADEMY ST
Address 2
City
SUMNER
County
PIERCE
State
WA
Zip
98390
Phone
2538264621
Status
ACTIVE
Specialty 1
PLUMBING
Specialty 2
UNUSED
Effective Date
9/20/2002
Expiration Date
9/20/2008
Suspend Date
Separation Date
Parent Company
Previous License
PLUMBE *077PR
Next License
Associated License
Business Owner Information
Name
Role
Effective Date
Expiration Date
KILDARE, JOHN T
PRESIDENT
09/20/2002
KILDARE, KRISTI
VICE PRESIDENT
09/20/2002
•
Bond Information
Bond
Bond
Company
Name
Bond Account
Number
Effective
Date
Expiration
Date
Cancel
Date
Impaired
Date
Bond
Amount
Received
Date
GREAT
AMER
INS CO
Until
Page 1 of 2
https: // fortress. wa. gov /lni/bbip /printer.aspx ?License =PLUMBEI98600 04/23/2008
PLUMBING RESPONSIITY SCHEDULE
FIXTURE SCHEDULE
FURNISHED BY
INSTALLED BY
ITEM
FIXTURE
ROUGH -IN SERVICES
DESCRIPTION
REMARKS
H31VM
0100
831VM
10H
31SVM
1N3A
INDIRECT
WASTE
Sd0
P1A
WATER CLOSET
TANK TYPE
1/2"
-
4"
2"
-
-
AMERICAN STANDARD "CADET" WATER CLOSET, MODEL NO. 2998.014 WITH
ELONGATED BOWL, VITREOUS CHINA BOWL, 16.5" HIGH, AMERICAN STANDARD
"LAUREL" WHITE OPEN FRONT SEAT AND COVER MODEL #5311.012.
FURNISH WITH BOLT CAPS AND CHROME SUPPLY STOP, AND TRIP LEVER
ON OPEN SIDE.
1.6 GPF
HANDICAP TYPE
P2A
LAVATORY
WALL MOUNTED
1/2"
1/2"
1-1/2"
1-1/2"
-
-
AMERICAN STANDARD "LUCERNE" LAVATORY, MODEL NO. 0356.421.
FURNISHED WITH CONCEALED ARM WALL HANGER, CHROME SUPPLY STOPS,
CHROME P -TRAP FOR WHEELCHAIR USE, AMERICAN STANDARD FAUCET
MODEL NO. 5501.170 WITH POP -UP DRAIN, WRIST BLADE HANDLES
INSULATED P -TRAP AND SUPPLY LINES WITH 1/2" ARMSTRONG "ANNAFLEX
PIPING INSULATION OR EQUIVALENT. MOUNT AT HEIGHT DIRECTED BY THE
ARCHITECT. DRAIN TO INCLUDE ADA PROTECTIVE PIPE COVER.
HANDICAP TYPE
IWH
INSTANTANEOUS
WATER HEATER
1/2"
1/2"
-
-
-
-
CHRONONMITE INSTANT -FLOW MODEL SR-30 (6.24 KW, 208V, 1 PHASE,
30A) POINT-OF-USE WATER HEATER WITH GLASS REINFORCED PLASTIC
HOUSING, REPLACEABLE NICKEL CHROME CARTRIDGE HEATING ELEMENT,
REPLACEABLE FILTER IN THE INLET CONNECTOR AND 1/2" PIPE
COMPRESSION NUTS OR 3/8" SLEEVES. UNIT SHALL HAVE A FLOW RATE
OF 0.5 GPM, SERVICING 1 LAVATORY, WITH A 40F RISE AVAILABLE AND A
MAXIMUM FACTORY TEMPERATURE SETTING OF 105F.
HB
HOSE BIBB
1/2"
-
-
-
-
-
NIBCO - ANGLE SILLCOCK VALVE MODEL 63 -CL, i" SIZE
FD
FLOOR DRAIN
-
--
3"
1 -1/2"
-
-
JAY R. SMITH MEDIUM DUTY MODEL 2110 SERIES, NO -HUB OUTLET, COATED
CAST IRON FLOOR DRAIN, WITH 1 ,4" PRIMER TAP, TWO -PIECE BODY, DOUBLE
DRAINAGE FLANGE, INVERTIBLE NON-- PUNCTURING FLASHING COLLAR,
WEEPHOLES, BOTTOM OUTLET INSIDE CAULK CONNECTION, ADJUSTABLE
ROUND SUPER -FLO STRAINER. ADJUSTABLE SQUARE "TYPE 5" STRAINER
FOR ALL DRAINS LOCATED IN TILED AREAS. STRAINER SHALL BE ZURN
COMPANY TYPE C, 5" DIAMETER POLISHED NICKEL BRONZE FINISH.
WATER HAMMER
ARRESTER
-
-
-
-
--
-
SIOUX CHIEF 650 SERIES WATER HAMMER ARRESTER OR EQUAL.
W_
TRAP PRIMER
1/2"
-
-
-
--
-
PRECISION PLUMBING PRODUCTS #ULP-500LP WITH ADJUSTABLE FLOW
RATE, INTEGRAL VACUUM BREAKER AND INTEGRAL BACKFLOW PREVENTER.
PLUMBING RESPONSIITY SCHEDULE
ITEM
FURNISHED BY
INSTALLED BY
REUSE
EXISTING
N \A
REMARKS
TENANT
LANDLORD
CONT'R
LANDLORD
CONT'R
OTHER
PLUMBING FIXTURES
COLD WATER PIPING, CW
— —
PC
PC
— --
GATE VALVE
WATER COOLER AND ACCESSORIES
--IA—
CHECK VALVE
WC
WATER CLOSET
LAV
X
LAVATORY
SEWER AND VENT PIPING
COLD WATER
PC
PC
IWH
INSTANTANEOUS WATER HEATER
CONDENSATE DRAIN PIPING
HC
HC
SECOND CONDENSATE DRAIN PIPING
X
GAS PIPING
X
CONDENSATE DRAIN PUMP
X
AS -BUILT DRAWINGS
PC
PC
•
PLUMBING SPEOFIC w ".• S
GENERAL
THE GENERAL CONDITIONS,
INSTRUCTIONS TO BIDDERS SHALL APPLY TO AND BE PART OF THIS
SPECIFICATION.
CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES, RULES
AND REGULATIONS.
CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS,
CERTIFICATES OF INSPECTION AND APPROVALS REQUIRED.
SCOPE OF WORK
WATER PIPING SYSTEMS
SOIL, WASTE, AND VENT PIPING SYSTEMS
PLUMBING FIXTURES
PLUMBING EQUIPMENT
PAINTING AND ELECTRICAL WORK IS NOT PART OF THIS CONTRACT.
GENERAL STANDARDS
THE APPLICABLE PROVISIONS OF THE FOLLOWING STANDARDS SHALL
GOVERN:
AMERICAN SOCIETY FOR TEST MATERIALS (ASTM);
AMERICAN STANDARDS ASSOCIATION (ASA);
UNDERWRITERS LABORATORIES (UL);
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA);
WASHINGTON BUILDING CODE.
THE INSTALLATION OF ALL PLUMBING WORK SHALL CONFORM TO
THE APPLICABLE LOCAL PLUMBING CODES AND STATUES.
EXCAVATION AND BACKFILL
DO ALL EXCAVATION AND BACKFILLING. LAY SEWER AND
UNDERGROUND PIPING LINES ON 6" COMPACTED SAND. BACKFILL
UNDER BUILDING AND ALL DRIVES, ROADS AND WALKS WITH
BANK -RUN GRAVEL.
WATER PIPING SYSTEMS
DOMESTIC COLD -WATER PIPING
DOMESTIC HOT -WATER PIPING
INTERIOR WATER PIPING:
TUBE SIZE 2" AND SMALLER: COPPER TUBE.
WALL THICKNESS: TYPE L, HARD -DRAWN TEMPER.
FITTINGS: WROUGHT - COPPER, SOLDER- JOINTS.
TUBE SIZE 2 -1/2" AND LARGER: COPPER TUBE.
WALL THICKNESS: TYPE L, HARD -DRAWN TEMPER.
FITTINGS: WROUGHT- COPPER, SOLDER - JOINTS.
SOIL. WASTE AND VENT PIPING SYSTEM
FURNISH AND INSTALL A COMPLETE SOIL, WASTE AND VENT SYSTEM
IN THE BUILDING AND ON THE SITE AS INDICATED ON THE
DRAWINGS AND AS SPECIFIED HEREIN. NO -HUB CAST IRON MAY BE
USED ABOVE FLOOR SLAB.
ABOVE GROUND SOIL, WASTE AND VENT PIPING WITHIN BUILDINGS
INCLUDING SOIL STACKS, VENT STACKS, HORIZONTAL BRANCHES,
TRAPS, AND CONNECTIONS TO FIXTURES AND DRAINS.
UNDERGROUND BUILDING DRAIN PIPING INCLUDING MAINS,
BRANCHES, TRAPS, CONNECTIONS TO FIXTURES AND DRAINS, AND
CONNECTIONS TO STACKS, TERMINATING AT CONNECTION TO EXISTING
SANITARY SEWER.
INTERIOR PIPING:
CAST IRON SOIL PIPING AND FITTINGS SERVICE WEIGHT ASTM A -74
WITH ASTM C -564 GASKETED JOINTS.
WASTE AND VENT PIPING 2 -1/2" AND UNDER - TYPE "M" COPPER
ASTM B88.62.
SOIL, WASTE AND VENT PIPING 3" AND OVER IN SIZE AND ALL
UNDERGROUND CAST IRON SOIL PIPING AND FITTINGS, ASTM A -74,
SERVICE WEIGHT.
NO -HUB CAST IRON PIPE AND FITTINGS MAY BE USED ABOVE
FLOOR FOR SOIL, WASTE, AND VENT PIPING.
PIPING ALIGNMENT SHALL BE AS INDICATED ON THE DRAWINGS
USING APPROVED Y BRANCHES OR EIGHT BANDS FOR DIRECTION
CHANGES AND SHALL BE SURELY SUPPORTED OR SECURED TO
MAINTAIN SUCH ALIGNMENT.
PITCH OF PIPING SHALL BE UNIFORM AT A MINIMUM OF 1/8" PER
FOOT FOR BUILDING DRAINS AND AS INDICATED ON THE DRAWINGS
FOR SEWERS.
PROTECTION SHALL BE GIVEN ALL FOOTINGS, OTHER STRUCTURAL
ELEMENTS DURING UNDERGROUND WORK ADJACENT TO SUCH ITEMS.
REFER TO STRUCTURAL DRAWINGS.
VENT ALL FIXTURES, CONNECT BRANCH VENTS TO MAIN VENT RISERS
AT LEAST THREE FEET AND SIX INCHES ABOVE VENTED FIXTURES.
PITCH VENT LINES BACK TO SOIL OR WASTE PIPE, FREE OF DROPS
AND SAGS.
CLEANOUTS SHALL BE FULL SIZE OF PIPE UP TO 4 ", AND 4" FOR
LARGER SIZES. FOR UNDERGROUND AND CONCEALED LINES,
PROVIDE CLEANOUTS IN ACCESSIBLE POSITIONS AT EACH RIGHT
ANGLE TURN AND AT INTERVALS NOT TO EXCEED FIFTY FEET. IN
FLOORS, INSTALL FLUSH WITH FINISH FLOOR WITH EXTENSION PIPE
FROM CLEANOUT "Y ".
PLUMBING FIXTURES
WATER CLOSETS.
LAVATORIES.
FIXTURE SCHEDULE
SEE PLUMBING DRAWINGS FOR FIXTURE SCHEDULE.
PLUMBING EQUIPMENT
ELECTRIC WATER HEATERS
CATHODIC PROTECTION
PROVIDE DIELECTRIC INSULATION AT POINTS WHERE COPPER OR
BRASS PIPE COMES IN CONTACT WITH FERROUS PIPING,
REINFORCING STEEL OR OTHER DISSIMILAR METAL IN STRUCTURE.
� ABSORBERS
REMOVE SHOCK CONDITIONS FROM ALL PIPING. PROVIDE AND
INSTALL SHOCK ABSORBERS ON ALL PIPING SERVING FLUSH VALVE
FIXTURES.
VALVES
MAIN SHUT OFF VALVES SHALL BE INSTALLED AS SHOWN ON THE
PLANS. SHUT OFF VALVES SHALL BE NIBCO S/T 580 BALL VALVES
OR EQUAL. VALVES SHALL HAVE BLOWOUT PROOF STEM, TFE SEATS
AND BRASS BALL. PRESSURE RATING OF ALL MAIN VALVES SHALL
HAVE A RATING OF AT LEAST 400 PSI WORKING PRESSURE.
VALVES SHALL BE INSTALLED AS SHOWN ON THE PLANS. WHEN
VALVES ARE NOT SHOWN IN DETAIL ON THE PLANS, THE
CONTRACTOR SHALL FURNISH AND INSTALL ALL VALVES NECESSARY
FOR THE CONTROL OPERATION AND ISOLATION OF EQUIPMENT.
PITCH ALL PIPE TO LOW POINTS AND INSTALL DRAIN VALVES.
GATE VALVES OR BALL VALVES SHALL BE USED IN SERVICES
REQUIRING THE VALVES TO BE FULLY OPENED OR TIGHTLY CLOSED.
GLOBE OR ANGLE VALVES SHALL BE USED WHERE THROTTLING OR
FLOW CONTROL IS DESIRED, OR IN BY -PASS LINES. GLOBE AND
ANGLE VALVES SHALL BE EQUIPPED WITH THE APPROPRIATE DISC
MATERIAL FOR THE INTENDED SERVICE. COLD WATER GLOBE VALVES
SHALL HAVE RUBBER DISC; HOT WATER SHALL HAVE COMPOSITION
DISC.
THIS CONTRACTOR SHALL FURNISH AND INSTALL SHUT -OFF VALVES
TO ISOLATE EACH FIXTURES, ITEM OR UNIT AT THE FIXTURE ITEMS
OR UNIT WHETHER FURNISHED BY THIS CONTRACTOR OR BY
OTHERS.
FIXTURES, ITEM OR UNITS FURNISHED BY THE MANUFACTURER WITH
INTEGRAL STOPS OR STOPS SPECIFIED WITH THE FIXTURE ARE
CONSIDERED TO BE PROPERLY VALVED OFF AT THE FIXTURES.
ACCESS SHALL BE PROVIDED TO ALL VALVES.
PIPE JOINTS AND CONNECTION
ALL CUTTING AND PATCHING OF FINISHED CONSTRUCTION OF
BUILDING SHALL BE PERFORMED BY THIS CONTRACTOR UNDER THE
SECTION OF SPECIFICATIONS COVERING THESE MATERIALS.
ANY MINOR ADJUSTMENT IN LOCATION OF ALIGNMENT OF NEW WORK
OR TO CONNECT TO EXISTING UTILITIES SHALL BE PERFORMED AS
DIRECTED BY THE ARCHITECT WITHOUT ADDITIONAL COST TO THE
OWNER.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGES TO THE
GROUNDS, WALKS, ROAD, BUILDING, PIPING SYSTEMS, ELECTRICAL
SYSTEMS, AND THEIR EQUIPMENT AND CONTENTS, CAUSED BY LEAKS
IN THE PIPING SYSTEMS BEING INSTALLED OR HAVING BEEN
INSTALLED BY HIM. HE SHALL REPAIR AT HIS EXPENSE ALL
DAMAGED SO CAUSED. ALL REPAIR WORK SHALL BE DONE AS
DIRECTED BY AND 'N SUCH MANNER AS SATISFACTORY TO THE
ARCHITECT.
OWNER RESERVES THE RIGHT TO MAKE EMERGENCY REPAIRS AS
REQUIRED TO KEEP EQUIPMENT IN OPERATION WITHOUT VOIDING THE
CONTRACTOR'S GUARANTEE BOND NOR RELIEVING THE CONTRACTOR
OF HIS RESPONSIBILITIES DURING THE BONDING PERIOD.
PIPE INSULATION
FIBERGLASS PIPING INSULATION: ASTM C 547, CLASS 1
FLEXIBLE CLOSED CELL ELASTOMERIC PIPING INSULATION: ASTM C
534, TYPE I, (EQUAL TO ARMAFLEX).
ENCASE PIPE FITTINGS INSULATION WITH ONE -PIECE PREMOLDED
PVC FITTING COVERS.
VAPOR BARRIER MATERIAL: PAPER - BACKED ALUMINUM FOIL, EXCEPT
AS OTHERWISE INDICATED, STRENGTH AND PERMEABILITY RATING
EQUIVALENT TO ADJOINING PIPE INSULATION JACKETING.
STAPLES, BANDS, WIRES, AND CEMENT: AS RECOMMENDED BY
INSULATION MANUFACTURER FOR APPLICATIONS INDICATED.
ADHESIVES, SEALERS, AND PROTECTIVE FINISHES: AS RECOMMENDED
BY INSULATION MANUFACTURER FOR APPLICATIONS INDICATED.
COVER ALL COLD WATER PIPING WITH 1/2" THICK FLEXIBLE CLOSED
CELL ELASTOMERIC INSULATION, HAVING A "K" VALUE OF .25.
COVER ALL HOT WATER PIPING WITH 3/4" THICK FLEXIBLE CLOSED
CELL ELASTOMERIC INSULATION, HAVING A "K" VALUE OF .25.
FLEXIBLE CLOSED CELL ELASTOMERIC INSTALLATION: SLIT TUBULAR
SECTIONS ONTO PIPE. ON AREAS WHERE PIPE END IS OPEN, SLIDE
FULL SECTIONS ONTO PIPE. ALL EDGES SHALL BE CLEAN CUT.
INSULATION SHALL BE PUSHED ONTO PIPE, NEVER PULLED. ALL
SEAMS AND BUTT JOINTS SHALL BE ADHERED AND SEALED USING
ADHESIVE EQUAL TO ARMAFLEX 520 ADHESIVE.
INTERRUPTION OF SERVICES
WHEN IT IS REQUIRED TO INTERRUPT EXISTING SERVICES, THIS
CONTRACTOR SHALL FIRST NOTIFY THE ARCHITECT THAT AN
INTERRUPTION IS REQUIRED. IT SHOULD BE NOTED THAT FACILITIES
MUST BY KEPT IN OPERATION AS MUCH AS POSSIBLE.
THIS CONTRACTOR SHALL ADVISE THE ARCHITECT OF THE LENGTH
OF TIME THE SERVICE WILL BE INTERRUPTED AND SHALL GET
PERMISSION FROM THE ARCHITECT BEFORE PROCEEDING WITH THE
WORK.
WARRANTY
THIS CONTRACTOR SHALL WARRANT THAT ALL WORK UNDER THIS
SECTION SHALL BE FREE OF DEFECTIVE WORK, MATERIALS AND
PARTS FOR A PERIOD OF ONE YEAR AFTER ACCEPTANCE OF THE
WORK AND SHALL REPAIR, REVISE, AND REPLACE, AT NO COST TO
THE OWNER, ANY SUCH DEFECTS OCCURRING WITHIN THE WARRANTY
PERIOD.
GENERAL PLUMBING NOTES
PRIOR TO BID, CONTRACTOR SHALL VISIT THE JOB SITE
AND FIELD VERIFY THE EXISTING CONDITIONS. THE
MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR
FIELD VERIFYING THE EXISTING STUB -INS, TAPS, ETC. FOR
PLUMBING AND MECHANICAL SYSTEMS FOR THE TENANT
SPACE. THE CONTRACTOR SHALL NOTIFY THE ENGINEER
IMMEDIATELY OF ANY DISCREPANCIES FOUND BETWEEN
PLANS AND FIELD CONDITIONS IN ORDER TO PREVENT
UNKNOWN ADDITIONAL COSTS TO THE TENANT.
ALL PIPING SYSTEMS SHALL BE PRESSURE TESTED IN
ACCORDANCE WITH STATE, LOCAL CODE AND LANDLORD'S
REQUIREMENTS.
PROVIDE SHUTOFF VALVE(S) AT EACH FIXTURE.
ALL WASTE AND VENT PIPING SHALL BE CAST IRON.
ALL UNDERGROUND SANITARY PIPES SHALL BE SCHEDULE
40 PVC. ALL ABOVE FLOOR SANITARY PIPING SHALL BE
SERVICE HEIGHT NO -HUB CAST IRON.
SLOPE ALL SANITARY PIPING 4" AND LARGER AT 1/8"
PER FOOT. SLOPE ALL SMALLER SANITARY PIPING AT
1/4" PER FOOT.
ALL PLUMBING PIPING DROPS TO PLUMBING FIXTURES
SHALL BE INSTALLED IN WALL SPACE EXCEPT WHERE
NOTED.
SUSPEND ALL HORIZONTAL WATER AND VENT PIPING AS
HIGH AS POSSIBLE ABOVE CEILING.
SAW CUT ALL SLAB PENETRATIONS. SEAL AROUND ALL
WALL, FLOOR AND CEILING PIPE PENETRATIONS WITH
APPROVED SEALANT MATERIAL AND ENSURE
PENETRATIONS REMAIN FIRE RESISTANT AND WATERTIGHT.
ALL EQUIPMENT, INSTALLATIONS AND MATERIALS SHALL
COMPLY WITH APPLICABLE LANDLORD CRITERIA, LOCAL
AND STATE CODES.
PROVIDE AND INSTALL WATER HAMMER ARRESTORS PER
PDI REQUIREMENTS.
PROVIDE AND INSTALL WATER METER WHERE SHOWN ON
PLANS.
LABEL ALL BELOW SLAB PIPING.
` 1
•
wco
SANITARY AND VENT PLUMBING PLAN
1/4" = 1
�G� N4-/-IS �E
CP
-o
t99
XXXXXXXX
5-
SANITARY AND VENT ISOMETRIC
N.T.S.
os
SEEfr i d �
x REQul �R� FOR:
E
'`a 't4°chani ,
Gas p; i
Plar review approval is subject to errors and omissions.
Approval of construction documents does not authorize
the violation of any adopted code or ordinance. $pp
of approved Field Copy and d is acknowledged:
BY
D 'I_ .2 3 - o
City of Tukwila
BUILDING DIVISION
Permit No.
FILE COPY
1514"
VALVE
SUPPLY
TUBE
YS- 8
SLOPE PIPING -,
BELOW SLAB TO
FLOOR DRAIN.
WATER TRAP -
DOMESTIC COLD
WATER LINE
TRAP PRIMER VALVE WITH BACKFLOW
PREVENTOR AND VACUUM BREAK
EQUAL TO PPP MODEL OREGON #1.
DISTRIBUTION UNITS FOR
MULTIPLE FLOOR DRAINS
MINIMUM 3/8" COPPER FLOOR DRAIN
TRAP MAKE -UP WATER LINE. (TYPICAL)
NOTE: TRAP PRIMER VALVE SHALL BE MOUNTED ONE FOOT ABOVE
THE FINISHED FLOOR FOR EVERY 20 FEET OF PRIMER LINE.
1/2" HW
INSTANTANEOUS
WATER
HEATER
CW
BELOW LAVATORY INSTALLATION
MOUNTS DIRECTLY BENEATH
THE BASIN USING ONLY ONE
PIPE
1/2" 3 WAY ANGLE
STOP VALVE
ftto : • XXXXX • ♦* • : XX X><><XXXXX><X I XXX:
... ... .. _ . -. - c ?. li +;_i }.'71�'�lti- . -'�'s - i `�. �: �.`: r - - ,:. _•, 1... - ?'Y.' �_'L'i5 i +��' `: r .. -� :.
0
HOT AND COLD WATER PLUMBING PLAN
1/4" = i ,_ o „
HOT AND COLD WATER ISOMETRIC
N.T.S.
PLUMBING CODED NOTES
O. PROVIDE NEW INSTANTANEOUS WATER HEATER BELOW
LAVATORY. SEE DETAIL FOR ADDITIONAL INFORMATION.
VERIFY IN FIELD EXACT LOCATION, COORDINATE WITH
GENERAL AND ELECTRICAL CONTRACTORS.
O EXTEND AND CONNECT NEW CW LINE TO EXISTING " CW
STUB IN THIS GENERAL AREA. VERIFY EXACT LOCATION
OF LANDLORD CW TAP PRIOR TO BEGINNING ANY WORK.
O EXTEND AND CONNECT NEW SANITARY LINE TO LANDLORD
PROVIDED MIN. 4" SANITARY LINE. FIELD VERIFY
LOCATION WITH LANDLORD REPRESENTATIVE PRIOR TO
BEGINNING ANY WORK.
O EXTEND AND CONNECT NEW 2" VENT PIPING TO
LANDLORD'S EXISTING 3" VENT STUB IN THIS GENERAL
LOCATION. FIELD VERIFY LOCATION WITH LANDLORD
REPRESENTATIVE PRIOR TO BEGINNING ANY WORK.
O5 EXISTING DOMESTIC WATER METER TO REMAIN.
O PROVIDE TRAP PRIMER AT FLOOR DRAIN. REFER TO
PLUMBING DETAILS FOR ADDITIONAL INFORMATION.
O7 INSTALL NEW HOSE BIBB WITH BOTTOM OF DISCHARGE AT
22" ABOVE FINISHED FLOOR.
RESPONSIBILITY SCHEDULES LEGEND AND CODED NOTES
PC = PLUMBING CONTRACTOR
HC = HVAC CONTRACTOR
RECEIVED
CITY OF TUKWILA
FEB D 0 7 2008
FeRMIT CENTER
t7-)
KOI'IRS LONNEMANN HELL
ENGINEE.r;S, PSC
MECHANICAL /ELECTRICAL ENGINEERS
1538 ALEXANDRIA PIKE, STE. 11
FT. THOMAS, KENTUCKY 41075
859 - 442 -8050
859 - 442 -8058 FAX
WWW.KLHENGRS.COM
DATE
NO.
*2*
PROJECT 8151.01
SHEET
DESCRIPTION
PLUMBING
PLANS AND
ISOMETRICS
1006 SOUTHCENTER MALL, TUKWILA, WA 98188
1600 NATIONAL AVENUE, SAN DIEGO, CA 92103
PROJECT COORDINATOR
GRAHAM DOWNES
T. 619.234.2565 F. 619.234.2568
PLUMING LEGEND
SYMBOL
DESCRIPTION
- - - S -- -
•
SANITARY /WASTE PIPING, S, W
V
VENT, V
CW
COLD WATER PIPING, CW
— —
•
HW
HOT WATER PIPING, HW
— --
GATE VALVE
DQ
--IA—
CHECK VALVE
WC
WATER CLOSET
LAV
LAVATORY
CW
COLD WATER
HW
HOT WATER
IWH
INSTANTANEOUS WATER HEATER
•
PLUMBING SPEOFIC w ".• S
GENERAL
THE GENERAL CONDITIONS,
INSTRUCTIONS TO BIDDERS SHALL APPLY TO AND BE PART OF THIS
SPECIFICATION.
CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES, RULES
AND REGULATIONS.
CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS,
CERTIFICATES OF INSPECTION AND APPROVALS REQUIRED.
SCOPE OF WORK
WATER PIPING SYSTEMS
SOIL, WASTE, AND VENT PIPING SYSTEMS
PLUMBING FIXTURES
PLUMBING EQUIPMENT
PAINTING AND ELECTRICAL WORK IS NOT PART OF THIS CONTRACT.
GENERAL STANDARDS
THE APPLICABLE PROVISIONS OF THE FOLLOWING STANDARDS SHALL
GOVERN:
AMERICAN SOCIETY FOR TEST MATERIALS (ASTM);
AMERICAN STANDARDS ASSOCIATION (ASA);
UNDERWRITERS LABORATORIES (UL);
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA);
WASHINGTON BUILDING CODE.
THE INSTALLATION OF ALL PLUMBING WORK SHALL CONFORM TO
THE APPLICABLE LOCAL PLUMBING CODES AND STATUES.
EXCAVATION AND BACKFILL
DO ALL EXCAVATION AND BACKFILLING. LAY SEWER AND
UNDERGROUND PIPING LINES ON 6" COMPACTED SAND. BACKFILL
UNDER BUILDING AND ALL DRIVES, ROADS AND WALKS WITH
BANK -RUN GRAVEL.
WATER PIPING SYSTEMS
DOMESTIC COLD -WATER PIPING
DOMESTIC HOT -WATER PIPING
INTERIOR WATER PIPING:
TUBE SIZE 2" AND SMALLER: COPPER TUBE.
WALL THICKNESS: TYPE L, HARD -DRAWN TEMPER.
FITTINGS: WROUGHT - COPPER, SOLDER- JOINTS.
TUBE SIZE 2 -1/2" AND LARGER: COPPER TUBE.
WALL THICKNESS: TYPE L, HARD -DRAWN TEMPER.
FITTINGS: WROUGHT- COPPER, SOLDER - JOINTS.
SOIL. WASTE AND VENT PIPING SYSTEM
FURNISH AND INSTALL A COMPLETE SOIL, WASTE AND VENT SYSTEM
IN THE BUILDING AND ON THE SITE AS INDICATED ON THE
DRAWINGS AND AS SPECIFIED HEREIN. NO -HUB CAST IRON MAY BE
USED ABOVE FLOOR SLAB.
ABOVE GROUND SOIL, WASTE AND VENT PIPING WITHIN BUILDINGS
INCLUDING SOIL STACKS, VENT STACKS, HORIZONTAL BRANCHES,
TRAPS, AND CONNECTIONS TO FIXTURES AND DRAINS.
UNDERGROUND BUILDING DRAIN PIPING INCLUDING MAINS,
BRANCHES, TRAPS, CONNECTIONS TO FIXTURES AND DRAINS, AND
CONNECTIONS TO STACKS, TERMINATING AT CONNECTION TO EXISTING
SANITARY SEWER.
INTERIOR PIPING:
CAST IRON SOIL PIPING AND FITTINGS SERVICE WEIGHT ASTM A -74
WITH ASTM C -564 GASKETED JOINTS.
WASTE AND VENT PIPING 2 -1/2" AND UNDER - TYPE "M" COPPER
ASTM B88.62.
SOIL, WASTE AND VENT PIPING 3" AND OVER IN SIZE AND ALL
UNDERGROUND CAST IRON SOIL PIPING AND FITTINGS, ASTM A -74,
SERVICE WEIGHT.
NO -HUB CAST IRON PIPE AND FITTINGS MAY BE USED ABOVE
FLOOR FOR SOIL, WASTE, AND VENT PIPING.
PIPING ALIGNMENT SHALL BE AS INDICATED ON THE DRAWINGS
USING APPROVED Y BRANCHES OR EIGHT BANDS FOR DIRECTION
CHANGES AND SHALL BE SURELY SUPPORTED OR SECURED TO
MAINTAIN SUCH ALIGNMENT.
PITCH OF PIPING SHALL BE UNIFORM AT A MINIMUM OF 1/8" PER
FOOT FOR BUILDING DRAINS AND AS INDICATED ON THE DRAWINGS
FOR SEWERS.
PROTECTION SHALL BE GIVEN ALL FOOTINGS, OTHER STRUCTURAL
ELEMENTS DURING UNDERGROUND WORK ADJACENT TO SUCH ITEMS.
REFER TO STRUCTURAL DRAWINGS.
VENT ALL FIXTURES, CONNECT BRANCH VENTS TO MAIN VENT RISERS
AT LEAST THREE FEET AND SIX INCHES ABOVE VENTED FIXTURES.
PITCH VENT LINES BACK TO SOIL OR WASTE PIPE, FREE OF DROPS
AND SAGS.
CLEANOUTS SHALL BE FULL SIZE OF PIPE UP TO 4 ", AND 4" FOR
LARGER SIZES. FOR UNDERGROUND AND CONCEALED LINES,
PROVIDE CLEANOUTS IN ACCESSIBLE POSITIONS AT EACH RIGHT
ANGLE TURN AND AT INTERVALS NOT TO EXCEED FIFTY FEET. IN
FLOORS, INSTALL FLUSH WITH FINISH FLOOR WITH EXTENSION PIPE
FROM CLEANOUT "Y ".
PLUMBING FIXTURES
WATER CLOSETS.
LAVATORIES.
FIXTURE SCHEDULE
SEE PLUMBING DRAWINGS FOR FIXTURE SCHEDULE.
PLUMBING EQUIPMENT
ELECTRIC WATER HEATERS
CATHODIC PROTECTION
PROVIDE DIELECTRIC INSULATION AT POINTS WHERE COPPER OR
BRASS PIPE COMES IN CONTACT WITH FERROUS PIPING,
REINFORCING STEEL OR OTHER DISSIMILAR METAL IN STRUCTURE.
� ABSORBERS
REMOVE SHOCK CONDITIONS FROM ALL PIPING. PROVIDE AND
INSTALL SHOCK ABSORBERS ON ALL PIPING SERVING FLUSH VALVE
FIXTURES.
VALVES
MAIN SHUT OFF VALVES SHALL BE INSTALLED AS SHOWN ON THE
PLANS. SHUT OFF VALVES SHALL BE NIBCO S/T 580 BALL VALVES
OR EQUAL. VALVES SHALL HAVE BLOWOUT PROOF STEM, TFE SEATS
AND BRASS BALL. PRESSURE RATING OF ALL MAIN VALVES SHALL
HAVE A RATING OF AT LEAST 400 PSI WORKING PRESSURE.
VALVES SHALL BE INSTALLED AS SHOWN ON THE PLANS. WHEN
VALVES ARE NOT SHOWN IN DETAIL ON THE PLANS, THE
CONTRACTOR SHALL FURNISH AND INSTALL ALL VALVES NECESSARY
FOR THE CONTROL OPERATION AND ISOLATION OF EQUIPMENT.
PITCH ALL PIPE TO LOW POINTS AND INSTALL DRAIN VALVES.
GATE VALVES OR BALL VALVES SHALL BE USED IN SERVICES
REQUIRING THE VALVES TO BE FULLY OPENED OR TIGHTLY CLOSED.
GLOBE OR ANGLE VALVES SHALL BE USED WHERE THROTTLING OR
FLOW CONTROL IS DESIRED, OR IN BY -PASS LINES. GLOBE AND
ANGLE VALVES SHALL BE EQUIPPED WITH THE APPROPRIATE DISC
MATERIAL FOR THE INTENDED SERVICE. COLD WATER GLOBE VALVES
SHALL HAVE RUBBER DISC; HOT WATER SHALL HAVE COMPOSITION
DISC.
THIS CONTRACTOR SHALL FURNISH AND INSTALL SHUT -OFF VALVES
TO ISOLATE EACH FIXTURES, ITEM OR UNIT AT THE FIXTURE ITEMS
OR UNIT WHETHER FURNISHED BY THIS CONTRACTOR OR BY
OTHERS.
FIXTURES, ITEM OR UNITS FURNISHED BY THE MANUFACTURER WITH
INTEGRAL STOPS OR STOPS SPECIFIED WITH THE FIXTURE ARE
CONSIDERED TO BE PROPERLY VALVED OFF AT THE FIXTURES.
ACCESS SHALL BE PROVIDED TO ALL VALVES.
PIPE JOINTS AND CONNECTION
ALL CUTTING AND PATCHING OF FINISHED CONSTRUCTION OF
BUILDING SHALL BE PERFORMED BY THIS CONTRACTOR UNDER THE
SECTION OF SPECIFICATIONS COVERING THESE MATERIALS.
ANY MINOR ADJUSTMENT IN LOCATION OF ALIGNMENT OF NEW WORK
OR TO CONNECT TO EXISTING UTILITIES SHALL BE PERFORMED AS
DIRECTED BY THE ARCHITECT WITHOUT ADDITIONAL COST TO THE
OWNER.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGES TO THE
GROUNDS, WALKS, ROAD, BUILDING, PIPING SYSTEMS, ELECTRICAL
SYSTEMS, AND THEIR EQUIPMENT AND CONTENTS, CAUSED BY LEAKS
IN THE PIPING SYSTEMS BEING INSTALLED OR HAVING BEEN
INSTALLED BY HIM. HE SHALL REPAIR AT HIS EXPENSE ALL
DAMAGED SO CAUSED. ALL REPAIR WORK SHALL BE DONE AS
DIRECTED BY AND 'N SUCH MANNER AS SATISFACTORY TO THE
ARCHITECT.
OWNER RESERVES THE RIGHT TO MAKE EMERGENCY REPAIRS AS
REQUIRED TO KEEP EQUIPMENT IN OPERATION WITHOUT VOIDING THE
CONTRACTOR'S GUARANTEE BOND NOR RELIEVING THE CONTRACTOR
OF HIS RESPONSIBILITIES DURING THE BONDING PERIOD.
PIPE INSULATION
FIBERGLASS PIPING INSULATION: ASTM C 547, CLASS 1
FLEXIBLE CLOSED CELL ELASTOMERIC PIPING INSULATION: ASTM C
534, TYPE I, (EQUAL TO ARMAFLEX).
ENCASE PIPE FITTINGS INSULATION WITH ONE -PIECE PREMOLDED
PVC FITTING COVERS.
VAPOR BARRIER MATERIAL: PAPER - BACKED ALUMINUM FOIL, EXCEPT
AS OTHERWISE INDICATED, STRENGTH AND PERMEABILITY RATING
EQUIVALENT TO ADJOINING PIPE INSULATION JACKETING.
STAPLES, BANDS, WIRES, AND CEMENT: AS RECOMMENDED BY
INSULATION MANUFACTURER FOR APPLICATIONS INDICATED.
ADHESIVES, SEALERS, AND PROTECTIVE FINISHES: AS RECOMMENDED
BY INSULATION MANUFACTURER FOR APPLICATIONS INDICATED.
COVER ALL COLD WATER PIPING WITH 1/2" THICK FLEXIBLE CLOSED
CELL ELASTOMERIC INSULATION, HAVING A "K" VALUE OF .25.
COVER ALL HOT WATER PIPING WITH 3/4" THICK FLEXIBLE CLOSED
CELL ELASTOMERIC INSULATION, HAVING A "K" VALUE OF .25.
FLEXIBLE CLOSED CELL ELASTOMERIC INSTALLATION: SLIT TUBULAR
SECTIONS ONTO PIPE. ON AREAS WHERE PIPE END IS OPEN, SLIDE
FULL SECTIONS ONTO PIPE. ALL EDGES SHALL BE CLEAN CUT.
INSULATION SHALL BE PUSHED ONTO PIPE, NEVER PULLED. ALL
SEAMS AND BUTT JOINTS SHALL BE ADHERED AND SEALED USING
ADHESIVE EQUAL TO ARMAFLEX 520 ADHESIVE.
INTERRUPTION OF SERVICES
WHEN IT IS REQUIRED TO INTERRUPT EXISTING SERVICES, THIS
CONTRACTOR SHALL FIRST NOTIFY THE ARCHITECT THAT AN
INTERRUPTION IS REQUIRED. IT SHOULD BE NOTED THAT FACILITIES
MUST BY KEPT IN OPERATION AS MUCH AS POSSIBLE.
THIS CONTRACTOR SHALL ADVISE THE ARCHITECT OF THE LENGTH
OF TIME THE SERVICE WILL BE INTERRUPTED AND SHALL GET
PERMISSION FROM THE ARCHITECT BEFORE PROCEEDING WITH THE
WORK.
WARRANTY
THIS CONTRACTOR SHALL WARRANT THAT ALL WORK UNDER THIS
SECTION SHALL BE FREE OF DEFECTIVE WORK, MATERIALS AND
PARTS FOR A PERIOD OF ONE YEAR AFTER ACCEPTANCE OF THE
WORK AND SHALL REPAIR, REVISE, AND REPLACE, AT NO COST TO
THE OWNER, ANY SUCH DEFECTS OCCURRING WITHIN THE WARRANTY
PERIOD.
GENERAL PLUMBING NOTES
PRIOR TO BID, CONTRACTOR SHALL VISIT THE JOB SITE
AND FIELD VERIFY THE EXISTING CONDITIONS. THE
MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR
FIELD VERIFYING THE EXISTING STUB -INS, TAPS, ETC. FOR
PLUMBING AND MECHANICAL SYSTEMS FOR THE TENANT
SPACE. THE CONTRACTOR SHALL NOTIFY THE ENGINEER
IMMEDIATELY OF ANY DISCREPANCIES FOUND BETWEEN
PLANS AND FIELD CONDITIONS IN ORDER TO PREVENT
UNKNOWN ADDITIONAL COSTS TO THE TENANT.
ALL PIPING SYSTEMS SHALL BE PRESSURE TESTED IN
ACCORDANCE WITH STATE, LOCAL CODE AND LANDLORD'S
REQUIREMENTS.
PROVIDE SHUTOFF VALVE(S) AT EACH FIXTURE.
ALL WASTE AND VENT PIPING SHALL BE CAST IRON.
ALL UNDERGROUND SANITARY PIPES SHALL BE SCHEDULE
40 PVC. ALL ABOVE FLOOR SANITARY PIPING SHALL BE
SERVICE HEIGHT NO -HUB CAST IRON.
SLOPE ALL SANITARY PIPING 4" AND LARGER AT 1/8"
PER FOOT. SLOPE ALL SMALLER SANITARY PIPING AT
1/4" PER FOOT.
ALL PLUMBING PIPING DROPS TO PLUMBING FIXTURES
SHALL BE INSTALLED IN WALL SPACE EXCEPT WHERE
NOTED.
SUSPEND ALL HORIZONTAL WATER AND VENT PIPING AS
HIGH AS POSSIBLE ABOVE CEILING.
SAW CUT ALL SLAB PENETRATIONS. SEAL AROUND ALL
WALL, FLOOR AND CEILING PIPE PENETRATIONS WITH
APPROVED SEALANT MATERIAL AND ENSURE
PENETRATIONS REMAIN FIRE RESISTANT AND WATERTIGHT.
ALL EQUIPMENT, INSTALLATIONS AND MATERIALS SHALL
COMPLY WITH APPLICABLE LANDLORD CRITERIA, LOCAL
AND STATE CODES.
PROVIDE AND INSTALL WATER HAMMER ARRESTORS PER
PDI REQUIREMENTS.
PROVIDE AND INSTALL WATER METER WHERE SHOWN ON
PLANS.
LABEL ALL BELOW SLAB PIPING.
` 1
•
wco
SANITARY AND VENT PLUMBING PLAN
1/4" = 1
�G� N4-/-IS �E
CP
-o
t99
XXXXXXXX
5-
SANITARY AND VENT ISOMETRIC
N.T.S.
os
SEEfr i d �
x REQul �R� FOR:
E
'`a 't4°chani ,
Gas p; i
Plar review approval is subject to errors and omissions.
Approval of construction documents does not authorize
the violation of any adopted code or ordinance. $pp
of approved Field Copy and d is acknowledged:
BY
D 'I_ .2 3 - o
City of Tukwila
BUILDING DIVISION
Permit No.
FILE COPY
1514"
VALVE
SUPPLY
TUBE
YS- 8
SLOPE PIPING -,
BELOW SLAB TO
FLOOR DRAIN.
WATER TRAP -
DOMESTIC COLD
WATER LINE
TRAP PRIMER VALVE WITH BACKFLOW
PREVENTOR AND VACUUM BREAK
EQUAL TO PPP MODEL OREGON #1.
DISTRIBUTION UNITS FOR
MULTIPLE FLOOR DRAINS
MINIMUM 3/8" COPPER FLOOR DRAIN
TRAP MAKE -UP WATER LINE. (TYPICAL)
NOTE: TRAP PRIMER VALVE SHALL BE MOUNTED ONE FOOT ABOVE
THE FINISHED FLOOR FOR EVERY 20 FEET OF PRIMER LINE.
1/2" HW
INSTANTANEOUS
WATER
HEATER
CW
BELOW LAVATORY INSTALLATION
MOUNTS DIRECTLY BENEATH
THE BASIN USING ONLY ONE
PIPE
1/2" 3 WAY ANGLE
STOP VALVE
ftto : • XXXXX • ♦* • : XX X><><XXXXX><X I XXX:
... ... .. _ . -. - c ?. li +;_i }.'71�'�lti- . -'�'s - i `�. �: �.`: r - - ,:. _•, 1... - ?'Y.' �_'L'i5 i +��' `: r .. -� :.
0
HOT AND COLD WATER PLUMBING PLAN
1/4" = i ,_ o „
HOT AND COLD WATER ISOMETRIC
N.T.S.
PLUMBING CODED NOTES
O. PROVIDE NEW INSTANTANEOUS WATER HEATER BELOW
LAVATORY. SEE DETAIL FOR ADDITIONAL INFORMATION.
VERIFY IN FIELD EXACT LOCATION, COORDINATE WITH
GENERAL AND ELECTRICAL CONTRACTORS.
O EXTEND AND CONNECT NEW CW LINE TO EXISTING " CW
STUB IN THIS GENERAL AREA. VERIFY EXACT LOCATION
OF LANDLORD CW TAP PRIOR TO BEGINNING ANY WORK.
O EXTEND AND CONNECT NEW SANITARY LINE TO LANDLORD
PROVIDED MIN. 4" SANITARY LINE. FIELD VERIFY
LOCATION WITH LANDLORD REPRESENTATIVE PRIOR TO
BEGINNING ANY WORK.
O EXTEND AND CONNECT NEW 2" VENT PIPING TO
LANDLORD'S EXISTING 3" VENT STUB IN THIS GENERAL
LOCATION. FIELD VERIFY LOCATION WITH LANDLORD
REPRESENTATIVE PRIOR TO BEGINNING ANY WORK.
O5 EXISTING DOMESTIC WATER METER TO REMAIN.
O PROVIDE TRAP PRIMER AT FLOOR DRAIN. REFER TO
PLUMBING DETAILS FOR ADDITIONAL INFORMATION.
O7 INSTALL NEW HOSE BIBB WITH BOTTOM OF DISCHARGE AT
22" ABOVE FINISHED FLOOR.
RESPONSIBILITY SCHEDULES LEGEND AND CODED NOTES
PC = PLUMBING CONTRACTOR
HC = HVAC CONTRACTOR
RECEIVED
CITY OF TUKWILA
FEB D 0 7 2008
FeRMIT CENTER
t7-)
KOI'IRS LONNEMANN HELL
ENGINEE.r;S, PSC
MECHANICAL /ELECTRICAL ENGINEERS
1538 ALEXANDRIA PIKE, STE. 11
FT. THOMAS, KENTUCKY 41075
859 - 442 -8050
859 - 442 -8058 FAX
WWW.KLHENGRS.COM
DATE
NO.
*2*
PROJECT 8151.01
SHEET
DESCRIPTION
PLUMBING
PLANS AND
ISOMETRICS
1006 SOUTHCENTER MALL, TUKWILA, WA 98188
1600 NATIONAL AVENUE, SAN DIEGO, CA 92103
PROJECT COORDINATOR
GRAHAM DOWNES
T. 619.234.2565 F. 619.234.2568