HomeMy WebLinkAboutPermit PG08-042 - PAYLESS SHOESPAYLESS SHOES 17250 SOUTHCENTER PY STE 128 PG08-042 Parcel No.: Address: Suite No: Citylbf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http : / /www.ci.tukwila.wa.us PLUMBING /GAS PIPING PERMIT 2623049117 17250 SOUTHCENTER PY TUKW Permit Number: Issue Date: Permit Expires On: PG08 -042 02/22/2008 08/20/2008 Tenant: Name: Address: Owner: Name: Address: PAYLESS SHOES 17250 SOUTHCENTER PY, STE 128 , TUKWILA WA WIG PROPERTIES LLC -SS 4811 134TH PL SE , BELLEVUE WA Contact Person: Name: JERRY BOHRER Address: PO BOX 2348 , VASHON WA Contractor: Name: CONTRACTOR'S PLUMBING SERV INC Address: PO BOX 2348 , VASHON WA Contractor License No: CONTRPS006KP Phone: Phone: 206 793 -8052 Phone: 206 763 -7400 Expiration Date: 11/06/2008 DESCRIPTION OF WORK: GROUNDWORK, ROUGH IN AND TRIM FOR (2) ADA RESTROOMS, MOP SINK AND DRINKING FOUNTAIN. Value of Plumbing /Gas Piping: Fees Collected: $4,800.00 $244.00 Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic - Dental unit, cuspidor - Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) - - Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory - Wash fountain - Receptor, indirect waste - -- 0 Sinks - 1 Urinals - 0 Water Closet 2 Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 FIXTURE TYPE AND OUANTITY 0 0 0 0 1 0 2 0 2 Plumbing (cont.) Building sewer and each trailer park sewer 0 Rain water system - per drain (inside bldg) 0 Water heater and /or vent 2 Industrial waste treatment interceptor, including its trap and vent, except for kitchen type grease interceptors - - 0 Repair or alteration of water piping and/or water treatment equipment 0 Repair or alteration of drainage or vent piping 0 Medical gas piping system serving (1 -5) inlets /outlets for a specific gas - - -- - -- Medical gas piping (6 +) inlets /outlets Gas Piping Gas piping outlets (0 -5) Gas piping outlets (6 +) - *continued on next page ** 0 0 0 doc: UPC -10/06 PG08 -042 Printed: 02 -22 -2008 City ofTukwila Department' of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206- 431 -3665 Web site: http://www.ci.tukwilawa.us Permit Number: PGO8 -042 Issue Date: 02/22/2008 Permit Expires On: 08/20/2008 Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied Date: ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or a performance of *O$ tit rized to sign and obtain this plumbing /gas piping permit. Signature: Print Name: .J Z-61 1-11 Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -10/06 PG08 -042 Printed: 02 -22 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 2623049117 Address: 17250 SOUTHCENTER PY TURIN Suite No: Tenant: PAYLESS SHOES PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: PG08 -042 ISSUED 02/14/2008 02/22/2008 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted' in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. * *continued on next page ** doc: Cond -10/06 PG08 -042 Printed: 02 -22 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Date: Z 1 2 k9:7 ordinances governing or local laws regulating doc: Cond -10/06 P608 =042 Printed: 02 -22 -2008 CITY OF TUKWILA Community Development Department Par-hit 'Centel- ,635036fittiEffiter 1314; Suite rOr) Tukwila, WA r,--913 http://www.ei.tukwila:wa.us Plumbing/Glitermit No. Project No. 1215q-i (For office,use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and Plans muk tit complete in Ordetto be accepted for plan reView. Applitations Will not be accepted through the mail or by fa)--L **Plea -g-6 Print** SITE LOCATION Site Aildr-egk ( s l (Yr, - 'Tenant Name: 74 S4406- Property Owners Name:_ -op Mailing Address: q 16_1 I 1 3 (.4 King Co Assessor's TaX NO.: 2: 3.0-74q1/7 /I PIC:1,44y iit Numberl _ Floor: fir NOV Tenant: Yes ,D.No City St5te Zip CONTACT PERSON _ mitio tin we.contact when your permit ts.ready Nain e:_ Mailing Address: . 2_ S4 e 11X1 /../ Addrtsk L es- 9 2-4-/---5---'"L S CAD Day Teleplidie: 2 o_ 92 67 2— _ e07 0 City State Zip Fax Number: jD & 3---14ert) 739 / CompanyName: ro.6t77"2-Verbie:f /P1=-On4 j IC25 Mailing Address:TO g-k,Ne Z 3 S_ ij lAtt 7 27_() City State Zip Contact Person: f _ — Liay Telephtme: 3 t-Mail Address: c-=-P‘ As-> '----- Contractor Registration Number: 0 5*-) / Rs 0 • Fax Number: 6 7 3 7 39 Expiration Date: / _ ARefiliT .F. Company Name: A f$:-_-0 Alb" ej Mailing AddreSS:ZI 0 Z _ Contact Person: City State Zip Day Telephone: 44- 2 S 416 2— q 471--e--71/ E-Mail Address: Fax Number: 116' 2-- 471— Company Name: L5-7 r--- Mailing Address: LI? 0-3-0 ^Pg."- R69/'-'1":"." Contact Person: _ City State Zip Day Telephone: 4257 'Z e2 E-Mail Address:_ Fax Number: _ 441 Q: \Applicalioni\FormvApplicationsiOnlirib \ 31200h Phirithing:das,PipiniPeriflit Abgicatibli:Cide Revised: bh Page 1 of 2 Valuation of Project (contractor's bid price): $ 7L SO 6-0 Scope of Work (please provide detailed information): i2-ovird P4 0 e- / evt)G t6 -25-J I % / 4.4) 2 A 1;4 /�'3 Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: 1 AN i(,)6( Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty . Fixture Type; Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain Z Sinks / Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Z Water Closet Z Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent _ Additional medical gas inlets /outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 E OR AUTHORIZED AGL%IYT: Signature: Print Name:i Pi 7 D4-/ >2-F7 _ Mailing Address: Date: Day Telephone: 42—De 7 9 IDate Application Accepted: City State Zip Date Application Expires: Deb Staff Initials: Q. 1Applicationaorms- Applications On LineG -2006 - Plumbing -Gas Piping Permit Application. doc Revised: 4-2006 bh Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049117 Permit Number: PG08 -042 Address: 17250 SOUTHCENTER PY TUKW Status: PENDING Suite No Applied Date: 02/14/2008 Applicant: PAYLESS SHOES Issue Date: Receipt No.: R08 -00428 Payment Amount: $244.00 Initials: JEM Payment Date: 02/14/2008 12:00 PM User ID: 1165 Balance: $0.00 Payee: CONTRACTOR'S PLUMBING SERVICE, INC, TRANSACTION LIST: Type Method Description Amount Payment Check 11996 244.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES PLUMBING - NONRES 000/345.830 44.00 000.322.103.00.0 200.00 Total: $244.00 8621. 02/14 9710 TOTAL 244.00 or. Raraint -CIA Printad n2- 14-2nn8 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1r-- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 1)60 e Project: �rsr 5�.,��� Type of Inspection: 1171, pI,, -t5` 7 Ad ss ZSo fD, 14e— 1 . L Date Called: Al Special Instructions: Date/ Wanted: a.m. Requester: Phone o/ !S I Approved per applicable codes. Corrections required prior to approval. COMMENTS: I r ' 4 f 'i ie ee InspectoQ_ afJAN Date: 3 Z J t% 0 $58.00 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: 44 3 INSPECTION NO. INSPECTION RECORD Retain a copy with permit P�0�- o9Z PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 4- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: Pal i ss skes Type of Inspection: , r:fvej Pt,.44 b.41 Address: /72 0 5,),Ajtveitref PL LAW Date Called: Special Instructions: ' ��/ ?AI O'l. A- V''' Ai r� LA A1at ` 11 J J Date Wanted: -fL, A aa..mm.. Requester: n -A, ro, s 5.,\ k Phone No: 09— 953 -2ea3( Approved per applicable codes. dCorrections required prior to approval. -_ COMMENTS: la c. (k- �cf' e -fL, A 1 l-oft z__6-2.64-1 (7 e' n -A, ro, s 5.,\ k I 2 n;n-r Of !& _ �(...„ �G-.,: „Ai IA/1 e/ /1-,1), ?,o .� 3 t-/,, )--k, A- ..S vk l 1�A 5 . t 1 fa i C_ it A (-- c E'J1 p A.c e Lit 771 i/ if e c� I Y i p f AA ,./ — to Inspec o "r: 1 Date: 3 c)(s., 0558.00 REINSPECTION FEE RE IRED. Prior o inspection, fee must be paid at 6300 Southcenter`Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: P6 o' -042_ INSPE ION NO. CITY OF TUKWILA BUILDING DIVISION It. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 INSPECTION RECORD Retain a copy with permit PERMIT NO. Project: c j, jk'y ( L $ S „1 k' `� .� Type of Inspf ction: `t"' I�.' y ,'4 i ,� rc'1(a • Addre�s. [ I q 250 S t.. zr r,.. Date Called: ,t Special Instructions: D to Wanted: 3 `1' 0 p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: f) A t ( i .` f vO `e ,- tr F' h c1 , lt--, 5` (.,,,ier: 1_ j �1 (: .12— , C ,i JX, 1 0.S f'.l ,, u ✓1t(S A. j ✓t - ,/'' 1 cA Date: El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION V- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 62_ Pgag,af Projer� es), F TyAe of Inspection: �pk� b. Address: 51 Date Cal d: M iP , I m uLeA A co A /� rt 8-6 Spec al Instructions: Date anted: / a.m. Requester: i Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: In vp pr:'&ir a ,��,� 6-- Al fri.oara -,-resr All dA7 ip Fl A: , A, ye !(e -d £,L 7 .—.. -:&7 - iP , I m uLeA A co A /� rt 8-6 4 e Id„ y� /�� � � t' 41 A. A Ak _ --/T� c-e- f f : ri e! 4 8 ,.):14 A5LAL A i Inspect o: d Dater 2 $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: y INSPECTION NO. INSPECTION RECORD Retain a copy with permit PCOU° c/Z CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 Proje t: 74-//94/6°5S S ,cC Type f Inspection: &ra7011,W G✓uv"it. Address: /7 ?SD Sr /hc�(...44'i cr Date Called: t Special Instructions: Date Wanted: 2 /2 .> 1‘"17. O L ‘"17. � p.m. Requester: Phone No: proved per applicable codes. Corrections required prior to approval. 7 COMMENTS: 8.00 REINSPECTION F�E REQUIR . Prior o inspection. fee must be aid at 6300 Southcenter Blvd., Suit 100. Call the schedule reinspection. Receipt No.: Date: . • _,.. - ti'.. _ - • PERMIT COORD COPY• PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG08 -042 DATE: 02 -14 -08 PROJECT NAME: PAYLESS SHOES SITE ADDRESS: 17250 SOUTHCENTER PY, STE 128 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Bui ing ivision Public Works l —n 4 s Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 02-19 -08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: Structural Review Required No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 03-18-08 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ___ Documents/routing slip.doc 2.28 -02 Look Up a Contractor, Electriiiin or Plumber License Detail Washington State Department of Labor and Industries General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. License Information License CONTRPS006KP Licensee Name CONTRACTOR'S PLUMBING SERV INC Licensee Type CONSTRUCTION CONTRACTOR UBI 602036912 Ind. Ins. Account Id 99267400 Business Type CORPORATION Address 1 PO BOX 2348 Address 2 City VASHON County KING State WA Zip 98070 Phone 2067637400 Status ACTIVE Specialty 1 PLUMBING Specialty 2 UNUSED Effective Date 5/17/2000 Expiration Date 11/6/2008 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date HAYES, AARON 01/01/1980 KELLNER, M BETH 01/01/1980 1 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Impaired Date Bond Amount Received Date #3 DEVELOPERS SURETY & INDEM CO 852500C 05/09/2001 Until Cancelled $6,000.00 10/23/2001 Page 1 of 2 https: / /fortress.wa.gov/ lni/ bbip/ printer .aspx?License= CONTRPS006KP 02/22/2008 WATER HEATER SCHEDULE DESIGNATION: WH -1 ZONE: RESTROOM MANUFACTURER: CHRONOMITE MODEL: SR -30L TYPE: INSTANTANEOUS WATTS: 3600 TEMP. RISE: 68T ® .5 GPM VOLTAGE: 120 PHASE: 1 REMARKS: (1)(2)(3)(4) (1) HEATER IS NOT REQUIRED BY UL TO HAVE PRESSURE & TEMPERATURE RELIEF VALVE FITTED. IF LOCAL CODES REQUIRE THE USE OF PRESSURE & TEMPERATURE RELIEF VALVE, IT SHOULD BE INSTALLED ON THE HOT WATER OUTLET PIPE BEFORE ISOLATING VALVE. DISCHARGE RELIEF TO OUTSIDE OR APPROVED LOCATION. (2) 45 PSIG MINIMUM WATER PRESSURE REQUIRED (3) 0.5 GPM FLOW RATE (4) FLOW SWITCH ACTIVATED: HEATING COILS ACTIVATE AT 0.4 GPM AND SHUT -OFF AT 0.3 GPM. PLUMBING FIXTURE CONNECTION SCHEDULE DESIG: ITEM: TRAP: WASTE: VENT: CW: HW: P1 WATER CLOSET (FT) 3" 4" 2" 1/2" - P2 LAVATORY (WALL -HUNG) 1-1/2" 1-1/2" 1-1/2" 1/2" 1/2" P3 WATER COOLER 1 -1/4" 1 -1/4" 1 --1/4" 1/2" - D1 FLOOR DRAIN 2" 2" 1-1/2" - - NOTES: 1. NO UNDERGROUND WASTE PIPING LESS THAN 2 ". 2. ALL FLOOR DRAINS SHALL HAVE TRAP PRIMER. Abossein Engineering MECHANICAL - ELEBICAL FIRE PROTECTION - ENERGY 2100 112TH AVE. NE BELLEVUE, WA 98004 PH: (425) 462 -9441 FAX: (425) 462 -9451 E -Mail: cservice @abossein.com Website: www.abossein.com i GENERAL MECHANICAL CONDITIONS 1. THE GENERAL AND SPECIAL CONDITIONS OF THE ARCHITECTURAL SPECIFICATIONS SHALL BE INCLUDED AS PART OF THESE DOCUMENTS. 2. ALL MATERIALS SHALL BE NEW UNUSED, AND THE BEST OF THEIR RESPECTIVE KINDS AND FREE FROM DEFECTS. 3. THIS CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE AIR DISTRIBUTION SYSTEM WITHIN THE TENANT SPACE TO INCLUDE, BUT NOT LIMITED TO ALL DUCTWORK, HANGERS, INSULATION, VAPOR BARRIER SUPPLY DIFFUSERS, RETURN GRILLS, FLEXIBLE CONNECTIONS, AND CONTROL INSTALLATION AS REQUIRED FOR A COMPLETE AND WORKING SYSTEM. THIS CONTRACTOR SHALL PAY ALL FEES, GIVE ALL NOTICES, FILE ALL NECESSARY DRAWINGS AND OBTAN ALL PERMITS AND CERTIFICATES OF APPROVAL REQUIRED IN CONNECTION WITH ALL WORK UNDER THIS CONTRACT. ALL WORK SHALL BE FURNISHED AND INSTALLED IN FULL ACCORDANCE WITH ALL LOCAL LAWS, ORDINANCES, RULES AND REGULATIONS. 4. DRAWNGS ARE DIAGRAMMATIC ONLY, INTENDING TO SHOW GENERAL RUNS AND LOCATIONS OF THE WORK AND ARE NOT INTENDED TO BE RIGID IN SPECIFIC DETAILS. 5. THE CONTRACTOR SHALL BE HELD TO HAVE EXAMINED THE SITE FOR HIS WORK BEFORE HAVING SUBMITTED HIS PROPOSAL. NO ADDITIONAL COMPENSATION WILL BE ALLOWED FOR CONDITIONS FOUND DURING THE COURSE OF THE CONTRACT. 6. THE CONTRACTOR SHALL VERIFY ALL MEASUREMENTS AT THE SITE AND BE RESPONSIBLE FOR THE CORRECTNESS OF THE SAME. 7. THE CONTRACTOR SHALL COORDINATE THE INSTALLATION OF HIS WORK WITH LIGHTING PLANS, REFLECTED CEILING PLANS AND ALL OTHER TRADES. 8. THE INSTALLATION OF ALL EQUIPMENT AND MATERIALS REQUIRING ACCESS SHALL BE MADE IN SUCH MANNER AS TO MAKE THE EQUIPMENT AND MATERIALS READILY ACCESSIBLE FOR OPERATION, MAINTENANCE AND REPAIRS. 9. STORAGE OF CONSTRUCTION EQUIPMENT AND MATERIALS SHALL BE ONLY IN SPACES AS DESIGNATED BY THE ARCHITECT /OWNER. 10. CONSTRUCTION DEBRIS AND RUBBISH GENERATED BY THIS CONTRACTOR SHALL BE REMOVED FROM PREMISES AS OFTEN AS NECESSSY OR AS DIRECTED TO MAINTAIN A CLEAN AND WORKABLE AREA. 11. ALL WORK AND EQUIPMENT IS TO BE FULLY GUARANTEED FOR ONE (1) YEAR FROM THE DATE OF FINAL PAYMENT AND ACCEPTANCE, EXCEPT FOR CARRIER HVAC COMPRESSORS WHICH SHALL CARRY A FIVE (5) YEAR GUARANTEE ON COMPRESSORS AND (10) YEAR ON HEAT EXCHANGERS. 12. ALL WORK, INCLUDING INSIDE OF AIR DUCTS, AND EQUIPMENT WITHIN THE CONTRACT AREA FURNISHED AND INSTALLED UNDER THIS CONTRACT SHALL BE CLEANED TO THE SATISFACTION OF THE OWNER BEFORE TURNING SAME OVER TO THE OWNER. 13. CONNECT NEW WORK TO EXISTING IN A NEAT AND APPROVED MANNER. 14. INTERRUPTION OF HEATING, POWER AND AUXILIARY SYTEMS WHERE AND IF REQUIRED SHALL BE COORDINATED AND SHALL OCCUR ONLY DURING PREARRANGED ACCEPTABLE TIMES. 15. ALL WORK SHALL INCORPORATE CURRENT ASHRAE METHODS AND SHALL MEET LOCAL SEISMIC SUPPORT AND BRACING REQUIREMENTS. GENERAL NOTES 1. COMPLETE INSTALLATION OF THE MECHANICAL SYSTEM SHALL BE PER THE STATE OF WASHINGTON BUILDING, MECHANICAL, ENERGY, FIRE, PLUMBING AND HEALTH CODES AND REGULATIONS AS ADOPTED BY THE LOCAL JURISDICTIONS. 2. ALL EQUIPMENT SHALL BE THE CAPACITY AND TYPES AS SHOWN ON THE EQUIPMENT SCHEDULE AND SHALL BE THE LISTED MANUFACTURER AND MODEL NUMBER. 3. THE CONTRACTOR SHALL SUBMIT MINIMUM OF SIX COPIES OF EQUIPMENT SUBMITTALS FOR APPROVAL. 4. CONTRACTOR IS TO BRING UP THE DISCREPANCIES AND ITEMS WHICH ARE NOT SPECIFICALLY CALLED FOR OR SHOWN BUT ARE REQUIRED FOR A COMPLETE MECHANICAL SYSTEM AND AFFECT HIS CONTRACT PRIOR TO ENTERING AND SIGNING THE CONTRACT; AFTER AWARDING THE CONTRACT ALL SUCH ITEMS REQUIRED FOR A COMPLETE SYSTEM READY FOR THE OWNER'S BENEFICIAL USE SHALL BE FURN!S, -IED AND INSTALLED INCLUDING ALL SUCH DISCREPANCY ITEMS MENTIONED ABOVE, AT NO ADDITIONAL COST TO THE OWNER AND PER LOCAL CODES. MANUFACTURER'S RECOMMENDATIONS AND APPLICABLE STANDARDS WITH THE ARCHITECT /ENGINEER'S APPROVAL 5. ALL EQUIPMENT SUPPLIED FOR THESE SPECIFICATIONS SHALL BE FREE FROM .DEFECTS IN MATERIAL, WORKMANSHIP, AND TITLE, AND SHALL BE OF THE KIND AND QUALITY DESCRIBED HEREIN. IF TT APPEARS WITHIN ONE YEAR FROM DATE OF FINAL ACCEPTANCE THAT EQUIPMENT DOES NOT MEET THE WARRANTIES ABOVE, THE CONTRACTOR SHALL IMMEDIATELY CORRECT ANY DEFECT AND SHALL RESTORE THE SYSTEM TO THE ORIGINAL SATISFACTORY CONDITIONS AT HIS EXPENSE. THE FOREGOING WARRANTY 1S EXCLUSIVE AND IN LIEU OF OTHER WARRANTIES, WHETHER WRITTEN, ORAL, IMPLIED OR STATUTORY. NO WARRANTY OF MERCHANT ABILITY OF FITNESS FOR PURPOSE SHALL APPLY. THE WARRANTY SHALL START FROM THE TIME OF TENANT /ENGINEERS FINAL ACCEPTANCE. 6. ENTIRE INSTALLATION OF ALL EQUIPMENT, CONTROL, PIPING, DUCTWORK AND RELATED ACCESSORIES SHALL BE PER BASIC BUILDING STANDARDS. MECHANICAL CONTRACTOR IS TO FAMILIARIZE HIMSELF WITH THESE STANDARDS. REFER TO BASIC BUILDING SPECIFICATIONS, DRAWINGS AND AMENDMENTS WHERE APPLICABLE. 7. MECHANICAL CONTRACTOR SHALL VISIT THE SITE AND VERIFY THE ROUTING AND INSTALLATION FEASIBILITY OF ALL EQUIPMENT, PIPING AND DUCTWORK PRIOR TO SUBMITTING HIS BID AND INCLUDE IN HIS BID ADDITIONAL PIPING, DUCTWORK, FITTINGS, OFFSETS, ETC. WHICH MIGHT BE REQUIRED FOR A COMPLETE SYSTEM READY FOR OWNER'S BENEFICIAL USE. 8. COORDINATE THE CONSTRUCTION SCHEDULE WITH THE TENANT /LANDLORD AND PERFORM ALL REQUIRED WORK IN STRICT ACCORDANCE WITH THE TENANT /LANDLORDS' SCHEDULES. 9. MECHANICAL CONTRACTOR SHALL PAY FOR AND OBTAIN ALL REQUIRED PERMITS AND CERTIFICATES REQUIRED BY THE AUTHORITIES HAVING JURISDICTION. 10. SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL SCOPE OF WORK, INSTRUCTION TO BIDDERS AND EXACT LOCATION OF ALL FIXTURES. 11. PLUMBING CONTRACTOR SHALL INSTALL ALL HOT AND COLD WATER PIPING WITHIN THE HEATED AREAS FOR FREEZE PROTECTION. 12. COORDINATE EXACT LOCATION OF ALL EQUIPMENT AND PENETRATIONS WITH THE ARCHITECTURAL, STRUCTURAL AND AT SITE. 13. ALL APPLICABLE CODES AND LOCAL JURISDICTION REGULATIONS SHALL SUPERSEDE THE CONSTRUCTION DOCUMENTS IF THEY ARE MORE STRINGENT. 14. INSTALL ALL TRAP ARMS SUCH THAT THE MAXIMUM LENGTH WILL NOT EXCEED THE CODE REQUIREMENTS. 15. ALL FIXTURES REQUIRING PLUMBING SHALL BE CONNECTED TO BUILDING WASTE, VENT, COLD WATER AND HOT WATER SYSTEM AS REQUIRED BY THE CODES. 16. INSTALL CLEANOUTS PER UPC - 2003 - SECTION 707 AND AS REQUIRED BY LOCAL JURISDICTIONS. 17. PIPE HANGERS AND SUPPORTS: PIPE HANGERS AND SUPPORTS SHALL BE IN STRICT ACCORDANCE WITH THE "UPC ", "IMC" AND PIPE MANUFACTURERS RECOMMENDATIONS. ALL PIPES SHALL BE SEISMICALLY RESTRAINED PER LATEST EDITION OF S.M.A.C.NA. SEISMIC RESTRAINT MANUAL AND AS REQUIRED BY LOCAL JURISDICTION. 18. THE CONTRACTOR SHALL INCLUDE ALL EXCAVATION AND BACKFILUNG REQUIRED FOR UNDERGROUND WORK IN HIS BID UNLESS OTHER ARRANGEMENTS ARE MADE WITH THE GENERAL CONTRACTOR PRIOR TO BIDDING. COORDINATE WITH LANDLORD /TENANT AND SITE /CIVIL ENGINEER. 19. ALL WATER LINES SHALL BE STERILIZED IN ACCORDANCE WITH THE A.W.W.A. STANDARDS AND LOCAL REGULATIONS. 20. ALL MATERIALS USED SHALL BE NEW AND BEAR U.L. LABEL WHEN REQUIRED. 21. ALL OPENINGS AND PENETRATIONS THROUGH ROOF AND /OR WALLS SHALL BE PROPERLY SEALED, WEATHERTIGHT, AND AESTHETICALLY ACCEPTABLE. 22. ALL CUTTING AND PATCHING REQUIRED FOR INSTALLATION OF NEW EQUIPMENT, FIXTURES AND PIPING TO BE BY CONTRACTOR. 23. ALL ROOF PATCHING TO BE BY LL. APPROVED CONTRACTOR AT TENANTS EXPENSE. 24. FINAL AS BUILT DRAWINGS SHALL BE SUBMITTED TO TENANT /ENGINEER. PLUMBING SPECIFICATIONS 1. PROVIDE A COMPLETE AND OPERATING PLUMBING SYSTEM AS INDICATED ON THE DRAWINGS. THE INSTALLATION SHALL BE COMPLETE WITH ALL FIXTURES, FITTINGS, TRIM AND ACCESSORIES TO PROVIDE A COMPLETE FUNCTIONING SYSTEM, PROVIDE FOR ALL CODE REQUIREMENTS AND HANDICAPPED PROVISIONS. 2. PROVIDE SQUARE TOP CLEANOUT COVERS ON FLOOR CLEANOUTS. SQUARE COVERS SHALL BE ALIGNED WITH BUILDING CONSTRUCTION AND FLUSH WTH FINISHED FLOOR. 3. COLD WATER SUPPLY PIPING SHALL BE TYPE "L" COPPER INSTALLED WITH LEAD SOLDER. SANITARY WASTE VENT PIPING MAY BE SERVICE WEIGHT CAST IRON WITH HUBLESS CONNECTOR FITTINGS OR DWV COPPER. COLD WATER SUPPLY PIPING SHALL BE INSULATED WITH A MINIMUN 1" FIBERGLASS WITH VAPOR PROOF ALL SERVICE JACKET OR EQUIVALENT CLOSED CELL FOAM INSULATION AS ALLOWED BY LOCAL CODES FOR INSTALLATION IN RETURN AIR PLENUMS. 4. ALL VALVE HANDLES SHALL BE COLOR CODED IN ORDER THAT THEY SHALL CORRESPOND AS FOLLOWS: A. BLUE - COLD WATER 5. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PIPING SUPPORTS, HANGERS AND METHODS FOR ATTACHMENT TO WALLS AND PARTITIONS. 6. NO PIPING SHALL RUN THROUGH DUCTWORK. 7. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, SPACES AND CONDITIONS PRIOR TO FABIRICATION AND INSTALLATION OF EQUIPMENT AND MATERIAL. 8. DIELECTRIC UNIONS SHALL BE PROVIDED WHEREVER DISSIMILAR METALS ARE JOINED. 9. REFER TO PLUMBING FIXTURE SCHEDULE FOR SPECIFICATIONS FOR NEW FIXTURES AS REQUIRED. 10. WATER CLOSETS AND ASSOCIATED FLUSH METER VALVES SHALL NOT USE MORE THAN 1.6 GAL /FLUSH. PLUMBING FIXTURE SCHEDULE P1: AMERICAN STANDARD, FLOOR MOUNTED, WHITE, VITREOUS CHINA, ELONGATED RIM, WATER SAVER TOILET #2216.143 WITH OPEN FRONT SEAT, HANDICAPPED HEIGHT, 1.6 GPF, STOPS, AND WING NUTS. P2: AMERICAN STANDARD LAVATORY #0124.024 WITH 7402.000 GOOSE NECK FAUCET SET, 0000.172H LEVER HANDLES, WALL MOUNTED, CONCEALED WALL HANGER, CARRIER AND CHROME P -TRAP. P3: OASIS P8ACSL, WATER COOLER WITH P -TRAP, SHUT -OFF AND REQUIRED MOUNTING HARDWARE. 8 GPH, ADA COMPUANT. 115V /60HZ /400W /4.6AMPS D1: JOSAM FLOOR DRAIN #30002 -A -50 WITH 2" TRAP & DRAIN, TRAP PRIMER INLET AND ROUND NIKALOY TOP STRAINER. TP1: JOSAM TRAP PRIMER VALVE #88250 WITH VACUUM BREAKER, 1/2" INLET AND 1/2" OUTLET. NOTES: 1. SEE ARCHITECTURAL PLANS FOR EXACT LOCATION AND QUANTITIES OF ALL THE PLUMBING FIXTURES AND DIFFERENT TYPES. 2. SEE ARCHITECTURAL PLANS TO DETERMINE EXACT CONFIGURATION AND ORIENTATION OF EACH FIXTURE. 3. ALL FIXTURES SHALL MEET THE STATE WATER CONSERVATION ACT REQUIREMENTS. 4. EXPOSED PIPES FOR HANDICAPPED LAVATORIES SHALL HAVE INSULATION JACKETS (HANDI-LAV-GUARD OR EQUAL). OFFSET EXPOSED P -TRAPS FOR CLEARANCE FOR HANDICAPPED ACCESS. 5. ALL FIXTURES SHALL INCLUDE ALL ACCESSORIES FOR A COMPLETE INSTALLATION INCLUDING BUT NOT UMITED TO ALL STRAINERS, DRAINS AND STOPS, WING NUTS, P-- TRAPS, ETC. 6. ALL EXPOSED P -TRAPS SHALL BE CHROME. 7. APPROVED EQUAL MANUFACTURERS ARE ELJER, KOHLER, AND ELKAY. 8. SEE SPECIFICATION FOR RESTOOM PLUMBING AND FIXTURES TO BE SUPPLIED. BRANCH THRU WALL TO SERVE SECOND LAV (NOT FOR MOP SINK) 0.5 GPM FLOW CONTROL (MUST BE INSTALLED) ON HEATER OUTLET SECURE TO WALL WITH TOGGLE BOLTS ELECTRICAL CONNECTION WITH ACCESS DOOR INSTANTANEOUS WATER HEATER NO SCALE (WH -1) GOOSENECK FAUCET WITH WATER FILTER. NOTE: INSTALL WATER HEATER PER THE MANUFACTURER'S RECOMMENDATIONS AND PER THE LOCAL CODES. INSULATED PIPES WITH HANDI -LAV -GUARD 3 -WAY STOP 1/2" COLD WATER NPT 1/2" TO LAVATORY 3/8" TO HEATER A LEGEND - COLD WATER (CW) - - HOT WATER (HW) SANITARY WASTE (W) VENT (V) PLAN NOTES CONNECT NEW Y4" CW PIPING TO EXISTING WATER SUPPLY. FIELD VERIFY EXISTING WATER PIPING LOCATION & SIZE. MOUNT ON WALL 5' JTF. CONNECT NEW 4" WASTE PIPING TO EXISTING SANITARY SEWER. FIELD VERIFY EXISTING LOCATION, SIZE AND INVERT. INSTANTANEOUS WATER HEATER LOCATED BELOW LAVATORY. SEE DETAIL "A /P -1 ". (WH -1) WATER SUPPLY SHUTOFF VALVE TO RESTROOMS. INSTALL IN ACCESSIBLE LOCATION, OMIT IF EXISTING. PROVIDE TRAP PRIMER ON FLOOR DRAINS, TYP. VERIFY WITH LANDLORD/TENANT FOR SUB METERING REQUIREMENTS PRIOR TO BIDDING. M _ . . .. r .. ..... ............. PARTIAL FLOOR PLAN - TOILET ROOM PLUMBING SCALE: 1/4"=1'-0" PLUMBING FIXTURE NO. ! FLOOR DRAIN (FD) N FLOOR CLEANOUT (FCO) VENT THRU ROOF • SCALE: 1/4 " =1' -0" FILE CCPM Permit No 05 PECEV: CITY` " - T.. °LA FEB 14 2008 PEHM17 CENTER Play review approval Is subject to ems and omissions. Approve' 0$ Construction documents does not authorize the violator of any adopted code or ordinance. Receipt 0 ' approved Field Copy and is acknowledged: City of Tukwila ' _:01 .4 4C1 DIVISION r`' t .......__ . .......... +..._.,...... LVMech n cal cAria LI 7 Gas Piping City o f T �'d iaa PARTIAL FLOOR PLAN - TOILET ROOM PLUMBING (WASTE & VENT UNDERGROUND) Project North Revisions ■ • �- .�- :■- Data P -1 1OF1 Description Feitl1T 3E MIRED FREIHEIT & HO ARCHITECTS, INC., P.S. O V)03 x „I O w N O LO r . wQ W V„ ¢�0 1 M N O I N to n STORE NO. 1723 SOUTHCENTER SQUARE TUKWILA, WA DRAWN BY: 5H, JAI, ONO DATE: 11/2/01 PROJECT NO.: A01 -652 PLUMBING PLAN ABOSSEIN PROTECT 412120