HomeMy WebLinkAboutPermit PG08-042 - PAYLESS SHOESPAYLESS SHOES
17250 SOUTHCENTER PY
STE 128
PG08-042
Parcel No.:
Address:
Suite No:
Citylbf Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http : / /www.ci.tukwila.wa.us
PLUMBING /GAS PIPING PERMIT
2623049117
17250 SOUTHCENTER PY TUKW
Permit Number:
Issue Date:
Permit Expires On:
PG08 -042
02/22/2008
08/20/2008
Tenant:
Name:
Address:
Owner:
Name:
Address:
PAYLESS SHOES
17250 SOUTHCENTER PY, STE 128 , TUKWILA WA
WIG PROPERTIES LLC -SS
4811 134TH PL SE , BELLEVUE WA
Contact Person:
Name: JERRY BOHRER
Address: PO BOX 2348 , VASHON WA
Contractor:
Name: CONTRACTOR'S PLUMBING SERV INC
Address: PO BOX 2348 , VASHON WA
Contractor License No: CONTRPS006KP
Phone:
Phone: 206 793 -8052
Phone: 206 763 -7400
Expiration Date: 11/06/2008
DESCRIPTION OF WORK:
GROUNDWORK, ROUGH IN AND TRIM FOR (2) ADA RESTROOMS, MOP SINK AND DRINKING
FOUNTAIN.
Value of Plumbing /Gas Piping:
Fees Collected:
$4,800.00
$244.00
Plumbing
Bathtub or combination bath/shower
Bidet
Clothes washer, domestic -
Dental unit, cuspidor -
Dishwasher, domestic, with independent drain
Drinking fountain or water cooler (per head) - -
Food -waste grinder, commercial
Floor drain
Shower, single head trap
Lavatory -
Wash fountain -
Receptor, indirect waste - -- 0
Sinks - 1
Urinals - 0
Water Closet 2
Uniform Plumbing Code Edition: 2006
International Fuel Gas Code Edition: 2006
FIXTURE TYPE AND OUANTITY
0
0
0
0
1
0
2
0
2
Plumbing (cont.)
Building sewer and each trailer park sewer 0
Rain water system - per drain (inside bldg) 0
Water heater and /or vent 2
Industrial waste treatment interceptor, including
its trap and vent, except for kitchen type
grease interceptors - - 0
Repair or alteration of water piping and/or water
treatment equipment 0
Repair or alteration of drainage or vent piping 0
Medical gas piping system serving (1 -5)
inlets /outlets for a specific gas - - -- - --
Medical gas piping (6 +) inlets /outlets
Gas Piping
Gas piping outlets (0 -5)
Gas piping outlets (6 +) -
*continued on next page **
0
0
0
doc: UPC -10/06
PG08 -042 Printed: 02 -22 -2008
City ofTukwila
Department' of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206- 431 -3665
Web site: http://www.ci.tukwilawa.us
Permit Number: PGO8 -042
Issue Date: 02/22/2008
Permit Expires On: 08/20/2008
Permit Center Authorized Signature:
I hereby certify that I have read and e
governing this work will be complied
Date:
ed this permit and know the same to be true and correct. All provisions of law and ordinances
whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or a performance of *O$ tit rized to sign and obtain this plumbing /gas piping permit.
Signature:
Print Name: .J
Z-61 1-11
Date:
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: UPC -10/06
PG08 -042 Printed: 02 -22 -2008
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Parcel No.: 2623049117
Address: 17250 SOUTHCENTER PY TURIN
Suite No:
Tenant: PAYLESS SHOES
PERMIT CONDITIONS
Permit Number:
Status:
Applied Date:
Issue Date:
PG08 -042
ISSUED
02/14/2008
02/22/2008
1: ** *PLUMBING AND GAS PIPING * **
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila
Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing
inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas
Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code.
Tests shall be conducted' in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to
make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless,
adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the
conditioned space shall be insulated to minimum R -3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be
protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing
piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in
accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to
twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill,
frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the
jurisdiction.
* *continued on next page **
doc: Cond -10/06
PG08 -042 Printed: 02 -22 -2008
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work
construction or the performance of work.
Date: Z 1 2 k9:7
ordinances governing
or local laws regulating
doc: Cond -10/06 P608 =042
Printed: 02 -22 -2008
CITY OF TUKWILA
Community Development Department
Par-hit 'Centel-
,635036fittiEffiter 1314; Suite rOr)
Tukwila, WA r,--913
http://www.ei.tukwila:wa.us
Plumbing/Glitermit No.
Project No. 1215q-i
(For office,use only)
PLUMBING / GAS PIPING PERMIT APPLICATION
Applications and Plans muk tit complete in Ordetto be accepted for plan reView.
Applitations Will not be accepted through the mail or by fa)--L
**Plea -g-6 Print**
SITE LOCATION
Site Aildr-egk ( s l (Yr, -
'Tenant Name: 74 S4406-
Property Owners Name:_ -op
Mailing Address: q 16_1 I 1 3 (.4
King Co Assessor's TaX NO.: 2: 3.0-74q1/7
/I PIC:1,44y iit Numberl _ Floor: fir
NOV Tenant: Yes ,D.No
City
St5te Zip
CONTACT PERSON _ mitio tin we.contact when your permit ts.ready
Nain e:_
Mailing Address: . 2_ S4 e 11X1 /../
Addrtsk L es- 9 2-4-/---5---'"L S CAD
Day Teleplidie: 2 o_ 92 67 2—
_ e07 0
City
State Zip
Fax Number: jD & 3---14ert) 739 /
CompanyName: ro.6t77"2-Verbie:f /P1=-On4 j IC25
Mailing Address:TO g-k,Ne Z 3 S_ ij lAtt 7 27_()
City State Zip
Contact Person: f _ — Liay Telephtme: 3
t-Mail Address: c-=-P‘ As-> '-----
Contractor Registration Number: 0 5*-) / Rs 0 •
Fax Number: 6 7 3 7 39
Expiration Date: / _
ARefiliT
.F.
Company Name: A f$:-_-0
Alb" ej
Mailing AddreSS:ZI 0 Z _
Contact Person:
City State
Zip
Day Telephone: 44- 2 S 416 2— q 471--e--71/
E-Mail Address: Fax Number: 116' 2-- 471—
Company Name: L5-7 r---
Mailing Address: LI? 0-3-0 ^Pg."- R69/'-'1":"."
Contact Person: _
City State Zip
Day Telephone: 4257 'Z e2
E-Mail Address:_ Fax Number: _ 441
Q: \Applicalioni\FormvApplicationsiOnlirib \ 31200h Phirithing:das,PipiniPeriflit Abgicatibli:Cide
Revised:
bh
Page 1 of 2
Valuation of Project (contractor's bid price): $ 7L SO 6-0
Scope of Work (please provide detailed information):
i2-ovird P4 0 e- / evt)G t6 -25-J I % / 4.4)
2 A 1;4 /�'3
Building Use (per Int'l Building Code):
Occupancy (per Int'l Building Code):
Utility Purveyor: Water: 1 AN i(,)6(
Sewer:
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
Fixture Type:
Qty
Fixture Type:
Qty
Fixture Type:
Qty
. Fixture Type;
Qty
Bathtub or combination
bath/shower
Drinking fountain or water
cooler (per head)
Wash fountain
Gas piping outlets
Bidet
Food -waste grinder,
commercial
Receptor, indirect
waste
Clothes washer, domestic
Floor drain
Z
Sinks
/
Dental unit, cuspidor
Shower, single head trap
Urinals
Dishwasher, domestic,
with independent drain
Lavatory
Z
Water Closet
Z
Building sewer or trailer
park sewer
Rain water system — per
drain (inside building)
Water heater and/or
vent
_
Additional medical gas
inlets /outlets — six or more
Industrial waste
pretreatment interceptor,
including its trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of water
piping and/or water treating
equipment
Repair or alteration
of drainage or vent
piping
Medical gas piping system
serving one to five
inlets/outlets for specific gas
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing
and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition).
I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING 0 E OR AUTHORIZED AGL%IYT:
Signature:
Print Name:i Pi 7 D4-/ >2-F7 _
Mailing Address:
Date:
Day Telephone: 42—De 7 9
IDate Application Accepted:
City
State
Zip
Date Application Expires:
Deb
Staff Initials:
Q. 1Applicationaorms- Applications On LineG -2006 - Plumbing -Gas Piping Permit Application. doc
Revised: 4-2006
bh
Page 2 of 2
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 2623049117 Permit Number: PG08 -042
Address: 17250 SOUTHCENTER PY TUKW Status: PENDING
Suite No Applied Date: 02/14/2008
Applicant: PAYLESS SHOES Issue Date:
Receipt No.: R08 -00428
Payment Amount: $244.00
Initials: JEM Payment Date: 02/14/2008 12:00 PM
User ID: 1165 Balance: $0.00
Payee: CONTRACTOR'S PLUMBING SERVICE, INC,
TRANSACTION LIST:
Type Method Description Amount
Payment Check 11996 244.00
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
PLAN CHECK - NONRES
PLUMBING - NONRES
000/345.830 44.00
000.322.103.00.0 200.00
Total: $244.00
8621. 02/14 9710 TOTAL 244.00
or. Raraint -CIA
Printad n2- 14-2nn8
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION 1r--
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
1)60 e
Project:
�rsr 5�.,���
Type of Inspection:
1171, pI,, -t5` 7
Ad ss
ZSo fD, 14e—
1
. L
Date Called:
Al
Special Instructions:
Date/ Wanted:
a.m.
Requester:
Phone o/
!S
I
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
I r ' 4 f 'i ie ee
InspectoQ_
afJAN
Date: 3 Z J t%
0 $58.00 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection.
Receipt No.:
Date:
44 3
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
P�0�- o9Z
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION 4-
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Project:
Pal i ss skes
Type of Inspection: ,
r:fvej Pt,.44 b.41
Address:
/72 0 5,),Ajtveitref PL LAW
Date Called:
Special Instructions: '
��/ ?AI
O'l. A- V''' Ai r� LA A1at ` 11 J
J
Date Wanted:
-fL, A
aa..mm..
Requester:
n -A, ro, s 5.,\ k
Phone No:
09—
953 -2ea3(
Approved per applicable codes.
dCorrections required prior to approval. -_
COMMENTS:
la c. (k- �cf' e
-fL, A
1 l-oft z__6-2.64-1 (7
e'
n -A, ro, s 5.,\ k
I
2 n;n-r Of !&
_
�(...„ �G-.,: „Ai
IA/1
e/
/1-,1), ?,o .�
3
t-/,, )--k, A-
..S vk l 1�A 5 .
t
1
fa i C_ it A (-- c E'J1 p A.c e
Lit 771
i/ if e
c�
I Y i p f AA ,./ —
to
Inspec o "r: 1
Date: 3 c)(s.,
0558.00 REINSPECTION FEE RE IRED. Prior o inspection, fee must be
paid at 6300 Southcenter`Blvd., Suite 100. Call the schedule reinspection.
Receipt No.:
Date:
P6 o' -042_
INSPE ION NO.
CITY OF TUKWILA BUILDING DIVISION It.
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
Project: c j,
jk'y ( L $ S „1 k' `� .�
Type of Inspf ction:
`t"' I�.' y ,'4 i ,� rc'1(a •
Addre�s. [
I q 250 S
t..
zr
r,..
Date Called:
,t
Special Instructions:
D to Wanted:
3
`1' 0
p.m.
Requester:
Phone No:
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
f) A t (
i .` f vO `e ,-
tr F' h c1 , lt--, 5`
(.,,,ier:
1_
j �1
(:
.12— , C ,i JX,
1 0.S f'.l ,, u ✓1t(S
A. j ✓t - ,/''
1
cA
Date:
El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection.
Receipt No.:
Date:
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION V-
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
62_
Pgag,af
Projer� es),
F
TyAe of Inspection:
�pk�
b.
Address:
51
Date Cal d:
M
iP , I
m uLeA A co A
/�
rt 8-6
Spec al Instructions:
Date anted:
/
a.m.
Requester:
i
Phone No:
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
In vp pr:'&ir a ,��,�
6-- Al fri.oara -,-resr All dA7
ip
Fl A:
, A, ye !(e -d £,L 7 .—.. -:&7 -
iP , I
m uLeA A co A
/�
rt 8-6
4 e Id„ y� /�� � �
t' 41 A. A Ak _ --/T� c-e- f
f : ri e! 4
8 ,.):14 A5LAL A
i
Inspect o:
d
Dater 2
$58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection.
Receipt No.:
Date:
y
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
PCOU° c/Z
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
PERMIT NO.
(206)431 -3670
Proje t:
74-//94/6°5S S ,cC
Type f Inspection:
&ra7011,W G✓uv"it.
Address:
/7 ?SD Sr /hc�(...44'i cr
Date Called:
t
Special Instructions:
Date Wanted:
2 /2
.>
1‘"17.
O L
‘"17.
�
p.m.
Requester:
Phone No:
proved per applicable codes.
Corrections required prior to approval.
7
COMMENTS:
8.00 REINSPECTION F�E REQUIR . Prior o inspection. fee must be
aid at 6300 Southcenter Blvd., Suit 100. Call the schedule reinspection.
Receipt No.:
Date:
. • _,.. - ti'.. _ -
• PERMIT COORD COPY•
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: PG08 -042 DATE: 02 -14 -08
PROJECT NAME: PAYLESS SHOES
SITE ADDRESS: 17250 SOUTHCENTER PY, STE 128
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # After Permit Issued
DEPARTMENTS:
Bui ing ivision
Public Works
l —n 4 s
Fire Prevention
Structural
Planning Division
Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
Incomplete n
DUE DATE: 02-19 -08
Not Applicable
Permit Center Use Only
INCOMPLETE LETTER MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
LETTER OF COMPLETENESS MAILED:
TUES/THURS ROUTING:
Please Route
REVIEWER'S INITIALS:
Structural Review Required No further Review Required
DATE:
APPROVALS OR CORRECTIONS:
Approved Approved with Conditions
Notation:
REVIEWER'S INITIALS:
DUE DATE: 03-18-08
Not Approved (attach comments) n
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ___
Documents/routing slip.doc
2.28 -02
Look Up a Contractor, Electriiiin or Plumber License Detail
Washington State Department of Labor and Industries
General /Specialty Contractor
A business registered as a construction contractor with L &I to perform
construction work within the scope of its specialty. A General or Specialty
construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
License Information
License
CONTRPS006KP
Licensee Name
CONTRACTOR'S PLUMBING SERV INC
Licensee Type
CONSTRUCTION CONTRACTOR
UBI
602036912
Ind. Ins. Account Id
99267400
Business Type
CORPORATION
Address 1
PO BOX 2348
Address 2
City
VASHON
County
KING
State
WA
Zip
98070
Phone
2067637400
Status
ACTIVE
Specialty 1
PLUMBING
Specialty 2
UNUSED
Effective Date
5/17/2000
Expiration Date
11/6/2008
Suspend Date
Separation Date
Parent Company
Previous License
Next License
Associated License
Business Owner Information
Name
Role
Effective Date
Expiration Date
HAYES, AARON
01/01/1980
KELLNER, M BETH
01/01/1980
1
Bond Information
Bond
Bond
Company
Name
Bond
Account
Number
Effective
Date
Expiration
Date
Cancel
Impaired
Date
Bond
Amount
Received
Date
#3
DEVELOPERS
SURETY &
INDEM CO
852500C
05/09/2001
Until
Cancelled
$6,000.00
10/23/2001
Page 1 of 2
https: / /fortress.wa.gov/ lni/ bbip/ printer .aspx?License= CONTRPS006KP 02/22/2008
WATER HEATER SCHEDULE
DESIGNATION:
WH -1
ZONE:
RESTROOM
MANUFACTURER:
CHRONOMITE
MODEL:
SR -30L
TYPE:
INSTANTANEOUS
WATTS:
3600
TEMP. RISE:
68T ® .5 GPM
VOLTAGE:
120
PHASE:
1
REMARKS:
(1)(2)(3)(4)
(1) HEATER IS NOT REQUIRED BY UL TO HAVE PRESSURE & TEMPERATURE RELIEF VALVE FITTED. IF LOCAL
CODES REQUIRE THE USE OF PRESSURE & TEMPERATURE RELIEF VALVE, IT SHOULD BE INSTALLED ON
THE HOT WATER OUTLET PIPE BEFORE ISOLATING VALVE. DISCHARGE RELIEF TO OUTSIDE OR APPROVED
LOCATION.
(2) 45 PSIG MINIMUM WATER PRESSURE REQUIRED
(3) 0.5 GPM FLOW RATE
(4) FLOW SWITCH ACTIVATED: HEATING COILS ACTIVATE AT 0.4 GPM AND SHUT -OFF AT 0.3 GPM.
PLUMBING FIXTURE CONNECTION SCHEDULE
DESIG:
ITEM:
TRAP:
WASTE:
VENT:
CW:
HW:
P1
WATER CLOSET (FT)
3"
4"
2"
1/2"
-
P2
LAVATORY (WALL -HUNG)
1-1/2"
1-1/2"
1-1/2"
1/2"
1/2"
P3
WATER COOLER
1 -1/4"
1 -1/4"
1 --1/4"
1/2"
-
D1
FLOOR DRAIN
2"
2"
1-1/2"
-
-
NOTES:
1. NO UNDERGROUND WASTE PIPING LESS THAN 2 ".
2. ALL FLOOR DRAINS SHALL HAVE TRAP PRIMER.
Abossein
Engineering
MECHANICAL - ELEBICAL
FIRE PROTECTION - ENERGY
2100 112TH AVE. NE
BELLEVUE, WA 98004
PH: (425) 462 -9441
FAX: (425) 462 -9451
E -Mail: cservice @abossein.com
Website: www.abossein.com
i
GENERAL MECHANICAL CONDITIONS
1. THE GENERAL AND SPECIAL CONDITIONS OF THE ARCHITECTURAL SPECIFICATIONS SHALL BE INCLUDED
AS PART OF THESE DOCUMENTS.
2. ALL MATERIALS SHALL BE NEW UNUSED, AND THE BEST OF THEIR RESPECTIVE KINDS AND FREE
FROM DEFECTS.
3. THIS CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE AIR DISTRIBUTION SYSTEM WITHIN THE
TENANT SPACE TO INCLUDE, BUT NOT LIMITED TO ALL DUCTWORK, HANGERS, INSULATION, VAPOR
BARRIER SUPPLY DIFFUSERS, RETURN GRILLS, FLEXIBLE CONNECTIONS, AND CONTROL INSTALLATION
AS REQUIRED FOR A COMPLETE AND WORKING SYSTEM. THIS CONTRACTOR SHALL PAY ALL FEES, GIVE
ALL NOTICES, FILE ALL NECESSARY DRAWINGS AND OBTAN ALL PERMITS AND CERTIFICATES OF
APPROVAL REQUIRED IN CONNECTION WITH ALL WORK UNDER THIS CONTRACT. ALL WORK SHALL BE
FURNISHED AND INSTALLED IN FULL ACCORDANCE WITH ALL LOCAL LAWS, ORDINANCES, RULES AND
REGULATIONS.
4. DRAWNGS ARE DIAGRAMMATIC ONLY, INTENDING TO SHOW GENERAL RUNS AND LOCATIONS OF THE
WORK AND ARE NOT INTENDED TO BE RIGID IN SPECIFIC DETAILS.
5. THE CONTRACTOR SHALL BE HELD TO HAVE EXAMINED THE SITE FOR HIS WORK BEFORE HAVING
SUBMITTED HIS PROPOSAL. NO ADDITIONAL COMPENSATION WILL BE ALLOWED FOR CONDITIONS
FOUND DURING THE COURSE OF THE CONTRACT.
6. THE CONTRACTOR SHALL VERIFY ALL MEASUREMENTS AT THE SITE AND BE RESPONSIBLE FOR THE
CORRECTNESS OF THE SAME.
7. THE CONTRACTOR SHALL COORDINATE THE INSTALLATION OF HIS WORK WITH LIGHTING PLANS,
REFLECTED CEILING PLANS AND ALL OTHER TRADES.
8. THE INSTALLATION OF ALL EQUIPMENT AND MATERIALS REQUIRING ACCESS SHALL BE MADE IN SUCH
MANNER AS TO MAKE THE EQUIPMENT AND MATERIALS READILY ACCESSIBLE FOR OPERATION,
MAINTENANCE AND REPAIRS.
9. STORAGE OF CONSTRUCTION EQUIPMENT AND MATERIALS SHALL BE ONLY IN SPACES AS DESIGNATED
BY THE ARCHITECT /OWNER.
10. CONSTRUCTION DEBRIS AND RUBBISH GENERATED BY THIS CONTRACTOR SHALL BE REMOVED FROM
PREMISES AS OFTEN AS NECESSSY OR AS DIRECTED TO MAINTAIN A CLEAN AND WORKABLE AREA.
11. ALL WORK AND EQUIPMENT IS TO BE FULLY GUARANTEED FOR ONE (1) YEAR FROM THE DATE OF
FINAL PAYMENT AND ACCEPTANCE, EXCEPT FOR CARRIER HVAC COMPRESSORS WHICH SHALL CARRY
A FIVE (5) YEAR GUARANTEE ON COMPRESSORS AND (10) YEAR ON HEAT EXCHANGERS.
12. ALL WORK, INCLUDING INSIDE OF AIR DUCTS, AND EQUIPMENT WITHIN THE CONTRACT AREA
FURNISHED AND INSTALLED UNDER THIS CONTRACT SHALL BE CLEANED TO THE SATISFACTION OF THE
OWNER BEFORE TURNING SAME OVER TO THE OWNER.
13. CONNECT NEW WORK TO EXISTING IN A NEAT AND APPROVED MANNER.
14. INTERRUPTION OF HEATING, POWER AND AUXILIARY SYTEMS WHERE AND IF REQUIRED SHALL BE
COORDINATED AND SHALL OCCUR ONLY DURING PREARRANGED ACCEPTABLE TIMES.
15. ALL WORK SHALL INCORPORATE CURRENT ASHRAE METHODS AND SHALL MEET LOCAL SEISMIC
SUPPORT AND BRACING REQUIREMENTS.
GENERAL NOTES
1. COMPLETE INSTALLATION OF THE MECHANICAL SYSTEM SHALL BE PER THE STATE OF WASHINGTON
BUILDING, MECHANICAL, ENERGY, FIRE, PLUMBING AND HEALTH CODES AND REGULATIONS AS ADOPTED
BY THE LOCAL JURISDICTIONS.
2. ALL EQUIPMENT SHALL BE THE CAPACITY AND TYPES AS SHOWN ON THE EQUIPMENT SCHEDULE AND
SHALL BE THE LISTED MANUFACTURER AND MODEL NUMBER.
3. THE CONTRACTOR SHALL SUBMIT MINIMUM OF SIX COPIES OF EQUIPMENT SUBMITTALS FOR APPROVAL.
4. CONTRACTOR IS TO BRING UP THE DISCREPANCIES AND ITEMS WHICH ARE NOT SPECIFICALLY CALLED
FOR OR SHOWN BUT ARE REQUIRED FOR A COMPLETE MECHANICAL SYSTEM AND AFFECT HIS CONTRACT
PRIOR TO ENTERING AND SIGNING THE CONTRACT; AFTER AWARDING THE CONTRACT ALL SUCH ITEMS
REQUIRED FOR A COMPLETE SYSTEM READY FOR THE OWNER'S BENEFICIAL USE SHALL BE FURN!S, -IED
AND INSTALLED INCLUDING ALL SUCH DISCREPANCY ITEMS MENTIONED ABOVE, AT NO ADDITIONAL COST
TO THE OWNER AND PER LOCAL CODES. MANUFACTURER'S RECOMMENDATIONS AND APPLICABLE
STANDARDS WITH THE ARCHITECT /ENGINEER'S APPROVAL
5. ALL EQUIPMENT SUPPLIED FOR THESE SPECIFICATIONS SHALL BE FREE FROM .DEFECTS IN MATERIAL,
WORKMANSHIP, AND TITLE, AND SHALL BE OF THE KIND AND QUALITY DESCRIBED HEREIN. IF TT
APPEARS WITHIN ONE YEAR FROM DATE OF FINAL ACCEPTANCE THAT EQUIPMENT DOES NOT MEET THE
WARRANTIES ABOVE, THE CONTRACTOR SHALL IMMEDIATELY CORRECT ANY DEFECT AND SHALL RESTORE
THE SYSTEM TO THE ORIGINAL SATISFACTORY CONDITIONS AT HIS EXPENSE. THE FOREGOING WARRANTY
1S EXCLUSIVE AND IN LIEU OF OTHER WARRANTIES, WHETHER WRITTEN, ORAL, IMPLIED OR STATUTORY.
NO WARRANTY OF MERCHANT ABILITY OF FITNESS FOR PURPOSE SHALL APPLY. THE WARRANTY SHALL
START FROM THE TIME OF TENANT /ENGINEERS FINAL ACCEPTANCE.
6. ENTIRE INSTALLATION OF ALL EQUIPMENT, CONTROL, PIPING, DUCTWORK AND RELATED ACCESSORIES
SHALL BE PER BASIC BUILDING STANDARDS. MECHANICAL CONTRACTOR IS TO FAMILIARIZE HIMSELF
WITH THESE STANDARDS. REFER TO BASIC BUILDING SPECIFICATIONS, DRAWINGS AND AMENDMENTS
WHERE APPLICABLE.
7. MECHANICAL CONTRACTOR SHALL VISIT THE SITE AND VERIFY THE ROUTING AND INSTALLATION FEASIBILITY
OF ALL EQUIPMENT, PIPING AND DUCTWORK PRIOR TO SUBMITTING HIS BID AND INCLUDE IN HIS BID
ADDITIONAL PIPING, DUCTWORK, FITTINGS, OFFSETS, ETC. WHICH MIGHT BE REQUIRED FOR A COMPLETE
SYSTEM READY FOR OWNER'S BENEFICIAL USE.
8. COORDINATE THE CONSTRUCTION SCHEDULE WITH THE TENANT /LANDLORD AND PERFORM ALL REQUIRED
WORK IN STRICT ACCORDANCE WITH THE TENANT /LANDLORDS' SCHEDULES.
9. MECHANICAL CONTRACTOR SHALL PAY FOR AND OBTAIN ALL REQUIRED PERMITS AND CERTIFICATES
REQUIRED BY THE AUTHORITIES HAVING JURISDICTION.
10. SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL SCOPE OF WORK, INSTRUCTION TO
BIDDERS AND EXACT LOCATION OF ALL FIXTURES.
11. PLUMBING CONTRACTOR SHALL INSTALL ALL HOT AND COLD WATER PIPING WITHIN THE HEATED AREAS
FOR FREEZE PROTECTION.
12. COORDINATE EXACT LOCATION OF ALL EQUIPMENT AND PENETRATIONS WITH THE ARCHITECTURAL,
STRUCTURAL AND AT SITE.
13. ALL APPLICABLE CODES AND LOCAL JURISDICTION REGULATIONS SHALL SUPERSEDE THE CONSTRUCTION
DOCUMENTS IF THEY ARE MORE STRINGENT.
14. INSTALL ALL TRAP ARMS SUCH THAT THE MAXIMUM LENGTH WILL NOT EXCEED THE CODE REQUIREMENTS.
15. ALL FIXTURES REQUIRING PLUMBING SHALL BE CONNECTED TO BUILDING WASTE, VENT, COLD WATER
AND HOT WATER SYSTEM AS REQUIRED BY THE CODES.
16. INSTALL CLEANOUTS PER UPC - 2003 - SECTION 707 AND AS REQUIRED BY LOCAL JURISDICTIONS.
17. PIPE HANGERS AND SUPPORTS:
PIPE HANGERS AND SUPPORTS SHALL BE IN STRICT ACCORDANCE WITH THE "UPC ", "IMC" AND PIPE
MANUFACTURERS RECOMMENDATIONS. ALL PIPES SHALL BE SEISMICALLY RESTRAINED PER LATEST
EDITION OF S.M.A.C.NA. SEISMIC RESTRAINT MANUAL AND AS REQUIRED BY LOCAL JURISDICTION.
18. THE CONTRACTOR SHALL INCLUDE ALL EXCAVATION AND BACKFILUNG REQUIRED FOR UNDERGROUND
WORK IN HIS BID UNLESS OTHER ARRANGEMENTS ARE MADE WITH THE GENERAL CONTRACTOR PRIOR
TO BIDDING. COORDINATE WITH LANDLORD /TENANT AND SITE /CIVIL ENGINEER.
19. ALL WATER LINES SHALL BE STERILIZED IN ACCORDANCE WITH THE A.W.W.A. STANDARDS AND LOCAL
REGULATIONS.
20. ALL MATERIALS USED SHALL BE NEW AND BEAR U.L. LABEL WHEN REQUIRED.
21. ALL OPENINGS AND PENETRATIONS THROUGH ROOF AND /OR WALLS SHALL BE PROPERLY SEALED,
WEATHERTIGHT, AND AESTHETICALLY ACCEPTABLE.
22. ALL CUTTING AND PATCHING REQUIRED FOR INSTALLATION OF NEW EQUIPMENT, FIXTURES AND PIPING
TO BE BY CONTRACTOR.
23. ALL ROOF PATCHING TO BE BY LL. APPROVED CONTRACTOR AT TENANTS EXPENSE.
24. FINAL AS BUILT DRAWINGS SHALL BE SUBMITTED TO TENANT /ENGINEER.
PLUMBING SPECIFICATIONS
1. PROVIDE A COMPLETE AND OPERATING PLUMBING SYSTEM AS INDICATED ON THE DRAWINGS. THE
INSTALLATION SHALL BE COMPLETE WITH ALL FIXTURES, FITTINGS, TRIM AND ACCESSORIES TO
PROVIDE A COMPLETE FUNCTIONING SYSTEM, PROVIDE FOR ALL CODE REQUIREMENTS AND
HANDICAPPED PROVISIONS.
2. PROVIDE SQUARE TOP CLEANOUT COVERS ON FLOOR CLEANOUTS. SQUARE COVERS SHALL BE ALIGNED
WITH BUILDING CONSTRUCTION AND FLUSH WTH FINISHED FLOOR.
3. COLD WATER SUPPLY PIPING SHALL BE TYPE "L" COPPER INSTALLED WITH LEAD SOLDER.
SANITARY WASTE VENT PIPING MAY BE SERVICE WEIGHT CAST IRON WITH HUBLESS CONNECTOR
FITTINGS OR DWV COPPER. COLD WATER SUPPLY PIPING SHALL BE INSULATED WITH A
MINIMUN 1" FIBERGLASS WITH VAPOR PROOF ALL SERVICE JACKET OR EQUIVALENT CLOSED CELL
FOAM INSULATION AS ALLOWED BY LOCAL CODES FOR INSTALLATION IN RETURN AIR PLENUMS.
4. ALL VALVE HANDLES SHALL BE COLOR CODED IN ORDER THAT THEY SHALL CORRESPOND AS FOLLOWS:
A. BLUE - COLD WATER
5. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PIPING SUPPORTS, HANGERS AND METHODS FOR
ATTACHMENT TO WALLS AND PARTITIONS.
6. NO PIPING SHALL RUN THROUGH DUCTWORK.
7. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, SPACES AND CONDITIONS PRIOR TO FABIRICATION AND
INSTALLATION OF EQUIPMENT AND MATERIAL.
8. DIELECTRIC UNIONS SHALL BE PROVIDED WHEREVER DISSIMILAR METALS ARE JOINED.
9. REFER TO PLUMBING FIXTURE SCHEDULE FOR SPECIFICATIONS FOR NEW FIXTURES AS REQUIRED.
10. WATER CLOSETS AND ASSOCIATED FLUSH METER VALVES SHALL NOT USE MORE THAN 1.6 GAL /FLUSH.
PLUMBING FIXTURE SCHEDULE
P1: AMERICAN STANDARD, FLOOR MOUNTED, WHITE, VITREOUS CHINA, ELONGATED RIM, WATER SAVER
TOILET #2216.143 WITH OPEN FRONT SEAT, HANDICAPPED HEIGHT, 1.6 GPF, STOPS, AND WING NUTS.
P2: AMERICAN STANDARD LAVATORY #0124.024 WITH 7402.000 GOOSE NECK FAUCET SET, 0000.172H
LEVER HANDLES, WALL MOUNTED, CONCEALED WALL HANGER, CARRIER AND CHROME P -TRAP.
P3: OASIS P8ACSL, WATER COOLER WITH P -TRAP, SHUT -OFF AND REQUIRED MOUNTING HARDWARE.
8 GPH, ADA COMPUANT. 115V /60HZ /400W /4.6AMPS
D1: JOSAM FLOOR DRAIN #30002 -A -50 WITH 2" TRAP & DRAIN, TRAP PRIMER INLET AND ROUND NIKALOY
TOP STRAINER.
TP1: JOSAM TRAP PRIMER VALVE #88250 WITH VACUUM BREAKER, 1/2" INLET AND 1/2" OUTLET.
NOTES:
1. SEE ARCHITECTURAL PLANS FOR EXACT LOCATION AND QUANTITIES OF ALL THE PLUMBING FIXTURES
AND DIFFERENT TYPES.
2. SEE ARCHITECTURAL PLANS TO DETERMINE EXACT CONFIGURATION AND ORIENTATION OF EACH
FIXTURE.
3. ALL FIXTURES SHALL MEET THE STATE WATER CONSERVATION ACT REQUIREMENTS.
4. EXPOSED PIPES FOR HANDICAPPED LAVATORIES SHALL HAVE INSULATION JACKETS (HANDI-LAV-GUARD
OR EQUAL). OFFSET EXPOSED P -TRAPS FOR CLEARANCE FOR HANDICAPPED ACCESS.
5. ALL FIXTURES SHALL INCLUDE ALL ACCESSORIES FOR A COMPLETE INSTALLATION INCLUDING BUT
NOT UMITED TO ALL STRAINERS, DRAINS AND STOPS, WING NUTS, P-- TRAPS, ETC.
6. ALL EXPOSED P -TRAPS SHALL BE CHROME.
7. APPROVED EQUAL MANUFACTURERS ARE ELJER, KOHLER, AND ELKAY.
8. SEE SPECIFICATION FOR RESTOOM PLUMBING AND FIXTURES TO BE SUPPLIED.
BRANCH THRU WALL
TO SERVE SECOND LAV
(NOT FOR MOP SINK)
0.5 GPM FLOW CONTROL
(MUST BE INSTALLED)
ON HEATER OUTLET
SECURE TO WALL
WITH TOGGLE BOLTS
ELECTRICAL CONNECTION
WITH ACCESS DOOR
INSTANTANEOUS WATER HEATER
NO SCALE
(WH -1)
GOOSENECK FAUCET WITH
WATER FILTER.
NOTE:
INSTALL WATER HEATER PER THE MANUFACTURER'S RECOMMENDATIONS
AND PER THE LOCAL CODES.
INSULATED PIPES WITH
HANDI -LAV -GUARD
3 -WAY STOP
1/2" COLD WATER NPT
1/2" TO LAVATORY
3/8" TO HEATER
A
LEGEND
- COLD WATER (CW)
- - HOT WATER (HW)
SANITARY WASTE (W)
VENT (V)
PLAN NOTES
CONNECT NEW Y4" CW PIPING TO EXISTING WATER SUPPLY. FIELD VERIFY
EXISTING WATER PIPING LOCATION & SIZE.
MOUNT ON WALL
5' JTF.
CONNECT NEW 4" WASTE PIPING TO EXISTING SANITARY SEWER. FIELD
VERIFY EXISTING LOCATION, SIZE AND INVERT.
INSTANTANEOUS WATER HEATER LOCATED BELOW LAVATORY.
SEE DETAIL "A /P -1 ". (WH -1)
WATER SUPPLY SHUTOFF VALVE TO RESTROOMS. INSTALL IN ACCESSIBLE LOCATION,
OMIT IF EXISTING.
PROVIDE TRAP PRIMER ON FLOOR DRAINS, TYP.
VERIFY WITH LANDLORD/TENANT FOR SUB METERING REQUIREMENTS PRIOR TO BIDDING.
M _ . . .. r .. ..... .............
PARTIAL FLOOR PLAN -
TOILET ROOM PLUMBING
SCALE: 1/4"=1'-0"
PLUMBING FIXTURE NO.
! FLOOR DRAIN (FD)
N FLOOR CLEANOUT (FCO)
VENT THRU ROOF
•
SCALE: 1/4 " =1' -0"
FILE CCPM
Permit No 05
PECEV:
CITY` " - T.. °LA
FEB 14 2008
PEHM17 CENTER
Play review approval Is subject to ems and omissions.
Approve' 0$ Construction documents does not authorize
the violator of any adopted code or ordinance. Receipt
0 ' approved Field Copy and
is acknowledged:
City of Tukwila
' _:01 .4 4C1 DIVISION
r`'
t .......__ . ..........
+..._.,......
LVMech n cal
cAria LI
7 Gas Piping
City o f T
�'d iaa
PARTIAL FLOOR PLAN - TOILET ROOM
PLUMBING (WASTE & VENT UNDERGROUND)
Project North
Revisions
■
•
�-
.�-
:■-
Data
P -1
1OF1
Description
Feitl1T 3E MIRED
FREIHEIT & HO
ARCHITECTS, INC., P.S.
O
V)03
x
„I
O
w N
O LO
r .
wQ
W V„
¢�0 1
M
N
O I
N to
n
STORE NO. 1723
SOUTHCENTER
SQUARE
TUKWILA, WA
DRAWN BY:
5H, JAI, ONO
DATE:
11/2/01
PROJECT NO.:
A01 -652
PLUMBING PLAN
ABOSSEIN PROTECT
412120