Loading...
HomeMy WebLinkAboutPermit PG08-074 - RAINIER INDUSTRIESRAINIER INDUSTRIES 18375 OLYMPIC AV S PGO8-O 74 Parcel No.: 7888900130 Address: Suite No: CityIlgf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PLUMBING /GAS PIPING PERMIT 18375 OLYMPIC AV S TUKW Permit Number: Issue Date: Permit Expires On: PG08 -074 03/25/2008 09/21/2008 Tenant: Name: RAINIER INDUSTRIES Address: 18375 OLYMPIC AV S , TUKVVILA WA Owner: Name: AMMEX CORPORATION Address: PO BOX 88047 , TUKWILA WA Contact Person: Name: KEO TORRE Address: 727 S KENYON ST , SEATTLE WA Contractor: Name: EVERGREEN REFRIGERATION LLC Address: 727 S KENYON ST , SEATTLE WA Contractor License No: EVERGRL954R2 Phone: Phone: 206 - 763 -1744 Phone: 206 763 -1744 Expiration Date: 01/06/2010 DESCRIPTION OF WORK: INSTALL GAS PIPING FOR (2) ROOFTOP HVAC UNITS AND (191) INFRARED HEATERS Value of Plumbing /Gas Piping: Fees Collected: $20,000.00 $261.00 Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory - Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 FIXTURE TYPE AND QUANTITY Plumbing (cont.) 0 Building sewer and each trailer park sewer 0 0 Rain water system - per drain (inside bldg) 0 0 Water heater and/or vent 0 0 Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 0 grease interceptors 0 0 Repair or alteration of water piping and/or water 0 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 0 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 0 0 Medical gas piping (6 +) inlets /outlets 0 0 Gas Piping 0 Gas piping outlets (0 -5) 5 0 Gas piping outlets (6 +) 16 * *continued on next page ** doc: UPC -10/06 PGO8 -074 Printed: 03 -25 -2008 City ofTukwila 0 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: PG08 -074 Issue Date: 03/25/2008 Permit Expires On: 09/21/2008 Permit Center Authorized Signature: Date: 0 * ;10/ I hereby certify that I have read and exI}nuied this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction o �; e perf•rmance of work. I am authorized to sign and obtain this plumbing /gas piping permit. Signature: W..Q, Print Name: \G/to —p This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Date: ?, /Z � l� 7 doc: UPC -10/06 PG08 -074 Printed: 03 -25 -2008 Parcel No.: 7888900130 Address: Suite No: Tenant: 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 18375 OLYMPIC AV S TUKW RAINIER INDUSTRIES PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: PG08 -074 ISSUED 03/10/2008 03/25/2008 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 8: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 9: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. * *continued on next page ** doc: Cond -10/06 PG08 -074 Printed: 03 -25 -2008 0 City of Tukwila 0 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: Date: '17/5 1d� ordinances governing or local laws regulating doc: Cond -10/06 PG08 -074 Printed: 03 -25 -2008 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://wiliw.ci.tulovilawa.us Building Permit No. Mechanical Permit No. KO E-O 7 Plumbing /Gas Permit No. p.()1 "0 '7 Public Works Permit No. Project No. Foe - 69 (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: 1 1 1 "8 W 1 3 d Site Address: it 3 1 5 01r+P' G 01'e S - _ _ Suite Number: 5141 Floor: Tenant Name: Property Owners Name: 4Inine4 CG►'i Wt +t Mailing Address: 1U 901- n 0 t-1 1 New Tenant: El Yes 125.. No V�,G✓i City State Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: Y.e.d W v ✓� Mailing Address: 12,1 S • -fah r +- 5,-444e. k/ - Day Telephone: z— �f?1H7`1 E -Mail Address: 04)0- cve.hunwint City State Zip Fax Number: 246-1 (9 T-4,311 GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: _ City Day Telephone: Fax Number: Expiration Date: Contact Person: E -Mail Address: Contractor Registration Number: State Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: City State Zip Contact Person :_ Day Telephone: E -Mail Address: Fax Number: ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Q:\Applications\Forms- Applications On Line\ -2006 - Permit Application.doc Revised: 9 -2006 bh Page 1 of 6 PLUMBING AND GAS PIPING PERMIT INFORMATION — 206 - 431 -3670 PLUMBING AND rsc D10h11 "Inrrn."lID 17".ORMATION 121 S k -tim s -tr-. Company Name: Mailing Address: Contact Person: v City State Zip Day Telephone:_ SOU 'S — 11L{"`1 E -Mail Address: Fax Number: zo6-- 't(l17- -77 Contractor Registration Number: I-V L e U & L 9 i-1 h Expiration Date: L Valuation of Plumbing work (contractor's bid price): $ Valuation of Gas Piping work (contractor's bid price): $ 10 , 000 of Scope of Work (please provide detailed information): 5 i P " .s7 re/ (74 - ot)F -ize Uh 14-) R ✓b■ 1 C4 yct s- 4 re4 Building Use (per Intl Building Code): Occupancy (per Intl Building Code): _ _- Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and /or gas piping outlets being installed and the quantity below: Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets j Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain Sinks Dental unit, cuspidor _ Shower, single head trap -_- Urinals — Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system – per drain (inside building) Water heater and/or vent - Additional medical gas inlets /outlets – six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors - - Repair or alteration of water piping and /or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets /outlets for specific gas Q :1Apphcations'Fornis- Appbeanans On Line \3-2006 - Permit Application doc Revised: 9 -2006 bh Page 5 of 6 1 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 i ER 0 A UTHORIZED AGENT: Signature: o Print Name: y (U f ✓.� Mailing Address: -7 2 Z 5, icvriien S 4- . Date: I/ I (2 id 3 Day Telephone: -7/1'6' fee, 14..t �A— 4ate f City State Zip Date Application Accepted: Date Application Expires: 0-0K Staff Initials: Q.\ApphcationsWorms- Applications On Line\ -2006 - Permit Application.doc Revised: 9 -2006 bh Page 6 of 6 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tultwiki.wa.ziS RECEIPT Parcel No.: 7888900130 Permit Number: PG08 -074 Address: 18375 OLYMPIC AV S TUKW Status: APPROVED Suite No: Applied Date: 03/10/2008 Applicant: RAINIER INDUSTRIES Issue Date: Receipt No.: R08 -00898 Initials: JEM User ID: 1165 Payment Amount: $208.80 Payment Date: 03/25/2008 03:03 PM Balance: $0.00 Payee: EVERGREEN REFRIGERATION, LLC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 003029 208.80 ACCOUNT ITEM LIST: Description Account Code Current Pmts GAS - NONRES 000.322.103.00.0 208.80 Total: $208.80 0398 03/25 9710 TOTAL 208.80 doc: Receiot -06 Pinted: 03 -25 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 7888900130 Address: 18375 OLYMPIC AV S TUKW Suite No: Applicant: RAINIER INDUSTRIES RECEIPT Permit Number: PG08 -074 Status: PENDING Applied Date: 03/10/2008 Issue Date: Receipt No.: R08 -00688 Initials: WER User ID: 1655 Payment Amount: $52.20 Payment Date: 03/10/2008 02:15 PM Balance: $208.80 Payee: EVERGREEN REFRIGERATION TRANSACTION LIST: Type Method Descriptio Amount Payment Check 003007 52.20 ACCOUNT ITEM LIST: Descript ion Account Code Current Pmts PLAN CHECK - NONRES 000/345.830 52.20 Total: $52.20 9685 03/10 9710 TOTAL 817.95 cAP\ doc: Receipt-06 Printed: 03 -10 -2008 INSPECTION NO. INSPECTION RECORD Retain a copy with permit %a- - & 1l PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 8- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project! 4 gL. n . e.2 34,As`K, P J Type of Inspection: r� AA (0 Af P. 4 , P, Ai Address: 101c OLT41/3;(- 44 Date Called: -f :).1 Ut-,LS 1,J,i, A 'Je L,ALt) ; ,Ajt,4-P(p7 Special Instructions: / Date Wanted: 2.4- Ja- aa.m.. p.m. Requester: Phone ri./0 ' r r11. ` J (3S r glApproved per applicable codes. Corrections required prior to approval. COMMENTS: --tfwc.,(Te.P 0 J T-)0 ,in-\--k--i Of Ca■1 . p ,/, . -A-t � _ C_or r, J .'1 .� � I cc��l i �J S -- '�'l(�� , -f :).1 Ut-,LS 1,J,i, A 'Je L,ALt) ; ,Ajt,4-P(p7 I6e 5 o ,. C`.. LS e r kf - f. . , i Inspec or: Date:/ „.14, v s/ ri $60.00 REINSPECTION FEE, REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: h INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 10' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 PG 08 -0`11 Pro }gct: , T jam. �C es .. -�-�'� : eJ'� Type of In�p� :n �j :40� / / (.� .,.�V Address : I Y3 `I 5 OLi ii- & f�v �- Date Called: _ Special Instructions: f' Date Wanted: / lO - 4-- ya m P•m• Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 6k5 T ? S - ?L_ JJl p TT t-1 A,17/. J e r� Inspector: Date: (0 n $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 1. _.. _b ..... .. d INSPECTION NO. INSPECTION RECORD Retain a copy with permit Ciro tig - (r /11 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #1 00, Tukwila, WA 98188 (206)431 -3670 Proje ,- PNitVe(r _t—k C Type of Inspectiont:' l (C 1`t— r 6AS. Address: 1 3-15OLLvv'VIc A Date Called: -US Special Instructions: / Date Wanted: 1- —23 —UP Requester: Phone No: _ 4.2-C-) C0 —mot 31- 3 7Z,i_ Approved per applicable codes. Corrections required prior to approval. - COMMENTS: 11 0A,(r Inspecto , GL1- d , Date:.4 ` ? ❑ $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: PG08 -074 PROJECT NAME: RAINIER INDUSTRIES SITE ADDRESS: 18375 OLYMPIC AVE S X Original Plan Submittal Response to Incomplete Letter # DATE: 03 -10 -08 Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: "Jr* B g 1I ision Public Works ?AAA. 3 -112 vr• Fire Prevention Structural n n Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 03-13-08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS RO TING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 04 -10-08 Not Approved (attach comments) Ti DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2-28-02 Look Up a Contractor, Electri n or Plumber License Detail Washington State Department of Labor and Industries General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. License Information License EVERGRL954R2 Licensee Name EVERGREEN REFRIGERATION LLC Licensee Type CONSTRUCTION CONTRACTOR UBI 602512953 Ind. Ins. Account Id 42245602 Business Type LIMITED LIABILITY COMPANY Address 1 727 S KENYON ST Address 2 City SEATTLE County KING State WA Zip 98108 Phone 2067631744 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 1/6/2006 Expiration Date 1/6/2010 Suspend Date Separation Date Parent Company Previous License EVERGI *201D7 Next License Associated License Business Owner Information Name Role Effective Date Expiration Date EVERGREEN REFRIGERATION LLC PARTNER/MEMBER 12/22/2005 PATTON, DAVID PARTNER/MEMBER 01/06/2006 PATTON, RODGER PARTNER/MEMBER 01/06/2006 PATTON, MATTHEW PARTNER/MEMBER 01/06/2006 Bond Information Bond Bond Company Account Effective Expiration Cancel Impaired Bond Received Page 1 of 2 https: // fortress .wa.gov /1ni/bbip /printer.aspx ?License= EVERGRL954R2 03/25/2008 SYMBOL LEGEND SYMBOL ABBV. DESCRIPTION Airflow S.P. Nominal RPM Voltage DUCT SECTION SUPPLY ►I Remarks Cooling Heating Electrical (CFM) DUCT SECTION - RETURN /EXHAUST 4 (V) Voltage - 1111111 RECTANGULAR DUCT 7 d GREENHECK G -095 -D 500 ROUND DUCT 1152 115 1 FLEXIBLE DUCT _L MVD MANUAL VOLUME DAMPER BDD BDD BACKDRAFT DAMPER I 4 MD MOTORIZED DAMPER ___4 FD FIRE DAMPER . FSD FIRE /SMOKE DAMPER (I20V POWER REQ.) - ® - I 115 CEILING RADIATION DAMPER sD SD SMOKE DETECTOR TQ T THERMOSTAT 0.25 S SENSOR R R REFRIGERANT LINES R G G NATURAL GAS LINES G 1152 115 1 1/8 CEILING DIFFUSER (SUPPLY) `I4 GREENHECK ® 500 CEILING DIFFUSER (RETURN /EXHAUST) 13 115 EXHAUST FAN (CEILING MOUNTED) 1/8 r o�j EF 7 NOT USED INLINE FAN 1, 2, 4, 6 n P ROPELLER FAN y MAR 11) ?MR \ I / SIDEWALL DIFFUSER PERMIT CENTER EF 8 -L-- GB- 300 -15 DUCT FITTING B. ❑,J. 12' 2' - f 550 DATUM 60 B•- 1) 3 Aitk 1, 3, 4 UNIT TAG v GB- 300 -15 8500 DUCT RISER ROOFTOP FAN SCHEDULE Tag Manufacturer Model Airflow S.P. Nominal RPM Voltage Phase H.P. Remarks Cooling Heating Electrical (CFM) (in. w.g.) Airflow (V) Voltage - 1111111 _ EF 1 GREENHECK G -095 -D 500 0.25 1152 115 1 1/8 1,2, 3 EF 2 GREENHECK G -095 -D 500 0.25 1152 115 1 1/8 1,2, 3 EF 3 GREENHECK G -095 -D 500 0.25 1152 115 1 1/8 1,2, 3 EF 4 GREENHECK G -095 -D 500 0.25 1152 115 1 1/8 1,2, 3 EF 5 GREENHECK G -095 -D 500 0.25 1152 115 1 1/8 1,2, 3 EF 6 GREENHECK G -095 -D 500 0.25 1152 115 1 1/8 1,2, 3 EF 7 NOT USED 2,447 1, 2, 4, 6 EF 8 GREENHECK GB- 300 -15 8500 0.125 550 208 3 1 1/2 1, 3, 4 EF 9 GREENHECK GB- 300 -15 8500 0.125 550 208 3 1 1/2 1, 3, 4 EF 10 GREENHECK GB- 300 -15 8500 0.125 550 208 3 1 1/2 1, 3, 4 EF 11 GREENHECK GB- 300 -15 8500 0.125 550 208 3 1 1/2 1, 3, 4 EF 12 GREENHECK GB- 220 -15 6400 0.125 862 208 3 1 1/2 1, 3, 4 EF 13 GREENHECK GB- 220 -15 6400 0.125 862 208 3 1 1/2 1, 3, 4 EF 14 GREENHECK GB- 420 -50 18300 0.125 459 208 3 5 1, 3, 4 EF 15 GREENHECK GB -420 -50 18300 0.125 459 208 3 5 1, 3, 4 EF 16 GREENHECK GB -420 -50 18300 0.125 459 208 3 5 1, 3, 4 SF 17 GREENHECK AS- 12 -420 -A4 813 0.125 1750 115 1 1/4 1, 5 SF 18 GREENHECK AS- 12-420 -A4 813 0.125 1750 115 1 1/4 1, 5 SF 19 GREENHECK AS- 12 -420 -A4 813 0.125 1750 115 1 1/4 1, 5 SF 20 GREENHECK AS -10- 420 -A8 401 0.125 1750 115 1 1/8 1, 5 SF 21 GREENHECK AS -10- 420 -A8 401 0.125 1750 115 1 1/8 1, 5 SF 22 GREENHECK AS- 16 -428 -A7 2802 0.125 1750 115 1 3/4 1 PACKAGED GAS /ELECTRIC UNIT SCHEDULE Tag IIMZMZESMMII Model Tons Airflow Min. OSA Supply Fan Supply Fan Power Exhaust Power Exhaust Cooling Heating Electrical ® Remarks Airflow Airflow Voltage - 1111111 kW SF 1 Motor HP S.P. (in. w.g.) Motor HP S.P. (in. w.g.) HP Current EER Input (Btuh) Output (Btuh) AFUE ( %) Voltage (V) Phase MCA (A) MOCP (A) Weight (Ibs) 115/1 1.3 144 (A) RTU 1 LENNOX SGA480S2 40 16,000 3,200 20 1.5 3 0.5 450,000 - 10 500,000 400,000 80% 460 3 116 125 7,336 1, 3, 4, 5, 6 RTU 2 LENNOX TGA180S2BM 15 6,000 1,200 5 0.8 - - 180,000 9.7 - 360,000 288,000 80% 460 3 38 40 2,447 1, 2, 4, 6 VARIABLE AIR VOLUME BOX SCHEDULE Tag Manufacturer UNIT# Manufacturer Model Max Primary Mn Primary Bectric Heater Watts Remarks Fan Total Bectrical L200 210 0.125 Airflow Airflow Voltage Phase kW SF 1 Voltage CSP -A390 Phase FLA HP Current 1.3 144 2, 3, 4 (CFM) (CFM) CSP -A390 271 0.25 1034 115/1 1.3 144 (A) SF 3 (A) VAV1.1 Price FDC4012 1450 439 480 3 ! 20.0 I 277 GREENHECK I 1 271 0.25 1034 CEILING MOUNTED EXHAUST FAN SCHEDULE Tag Manufacturer Model Airflow (CFM) S.P. (ins) Nominal RPM Voltage Amps I Watts Remarks CEF 1 Broan L200 210 0.125 740 120/1 1.8 127 1, 2 SF 1 GREENHECK CSP -A390 271 0.25 1034 115/1 1.3 144 2, 3, 4 SF 2 GREENHECK CSP -A390 271 0.25 1034 115/1 1.3 144 2, 3, 4 SF 3 GREENHECK CSP -A390 271 0.25 1034 115/1 1.3 144 2, 3, 4 SF 4 GREENHECK CSP-A390 271 0.25 1034 115/1 1.3 144 2, 3, 4 INFRARED HEATER SCHUDULE Tag Manufacturer Model Heating Electrical Unit Remarks Electrical Weight Remarks Input Voltage Phase I Amps Weight (ins) (ins) Rated Capacity (Btuh) G.O.P. (Ibs) (Btuh) (V/) I (A) (Ibs) FGI r 41x41 IR 1 SPACE -RAY LTU 225-50 N5 250,000 120 1 2.5 312 1 IR 2 SPACE -RAY LTU 175-40 N5 175,000 120 1 2.5 241 16 BAROMETRIC RELIEF HOOD SCHEDULE Tag Manufacturer Manufacturer Tons Model Throat Size Curb Size Electrical Weight Remarks ^ (CFM) (ins) (ins) Rated Capacity (Btuh) G.O.P. (Ibs) M.C.A. BH 1 I GREENHECK 1 FGI r 41x41 I 47x47 I 178 I 1 DUCTLESS SPLIT SYSTEM HEAT PUMP SCHEDULE Tag Manufacturer Model Tons Airflow Cooling Heating Electrical Weight Remarks ^ (CFM) Rated Capacity (Btuh) SEER Rated Capacity (Btuh) G.O.P. Volts Phase M.C.A. (Ibs) AH -1 Mitsubishi MSZA24NA 2 568 - -- - - 208 1 1 37 1, 2 CU -1 Mitsubishi MUZA24NA 2 - 22000 16 15200 2.89 208 1 17 128 3 K emarKs: 1. Provide smoke detector installed by mechanical contractor, wiring by electrical contractor 2. Provide 100% outside air economizer, barometric relief, and roof curb 3. Provide 100% outside air economizer, power exhaust, and roof curb 4. All power wiring and disconnects by electrical contractor 5. Factory installed VFDs on supply fan and power exhaust fan 6. To be integrated into the DDC control system Remarks: 1. Provide with curb Remarks: 1. Mount heaters 28' A.F.F. 2. Heaters to be controlled by line voltage thermostats with locking covers that are provided by ERL and installed by and installed by others. 3. Heaters to vent to the roof with Type B vent pipe Remarks: 1. Fans are to be switched by a line voltage thermostat that is supplied by ERL and installed by others. 2 Fans are to vent to the roof through manufacturer roof caps FILE :• PY Permit No. Plar review approval Is subject to errors and omissions. Approval of won documents does not authorize the violation of any adopted code or ordinance. Receipt 0 approved FI and cis is ` Date: 31•2.5 / U 5 City of Tukwila BUILDING DIVISION REVISIONS No changes shall b me ade to o val Conn of work without prior app Tukwila Building Division NOTE: Revisions will require a new plan submittal and may include additional plan review fees 6 El - ARATE PERMIT i REQUIRED FOR: eChanicai Nfi Electrical is Plumbin 0 Gas Piping City of Tukwila BUILDING DIVISION Remarks: • 1. Mount indoor unit on wail 2. Include integrated thermostat 3. Mount outdoor unit on sleepe and connect to the indoor unit with a th refrigerant piping A Remarks: COMPLETION AND COMMISSIONING FOR MECHANICAL SYSTEMS RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER WA ENERGY CODE (WSEC) SECTION 1416.1. AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER PER WSEC SECTION 1416.2. ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCE REPORT SHALL BE PROVIDED TO THE OWNER PER WSEC SECTION 14516.2.2.2. FOR WAREHOUSES SEMIHEATED SPACES AND SIMPLE SYSTEMS (AS DEFINED IN WSEC SECTION 1421): HVAC CONTROL SYSTEMS SHALL BE TESTED, CALIBRATED AND ADJUSTED, SEQUENCES OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORD WITH SPECIFICATIONS AND APPROVED PLANS, AND A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE FILED WITH THE OWNER PER WSEC SECTION 1416.4.1. FOR ALL OTHER SYSTEMS: HVAC CONTROL SYSTEMS SHALL BE TESTED, CALIBRATED AND ADJUSTED, SEQUENCES OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORD WITH SPECIFICATIONS AND APPROVED PLANS PER WSEC SECTION 1416.2.3.2; NECESSARY TESTS SHALL BE IDENTIFIED PER WSEC SECTION 1416.2.3; A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY PER WSEC SECTION 1416.2.5.1 AND A COMPLETE FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE FILED WITH THE OWNER PER WSEC SECTION 1416.2.5.2. GENERAL NOTES DUCTWORK 1.1 ALL DUCT DIMENSIONS ON PLAN ARE CLEAR INSIDE DIMENSIONS, ADD 2" TO EACH DIMENSION TO OBTAIN OUTSIDE DIMENSION. ADD 4 EACH DIMENSION IF DUCTWORK IS ON THE EXTERIOR OF BUILDING. 1.2 THE FIRST NUMBER ON ALL DUCT DIMENSIONS IS THE WIDTH AND THE SECOND NUMBER IS THE HEIGHT. 1.3 MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT RATING LESS THAN 50, PER IMC 602.2.1. 1.4 SEAL ALL TRANSVERSE JOINTS FOR DUCTWORK WITH STATIC PRESSURE BETWEEN 112 INCHES AND 2 INCHES. DUCTWORK WHICH IS DESIGNED TO OPERATE AT PRESSURES ABOVE 1/2 INCH WATER COLUMN STATIC PRESSURE SHALL BE SEALED IN ACCORDANCE WITH STANDARD RS -7. 1.5 ALL DUCT GAUGES PER SMACNA, IMC 603-4. 1.6 ALL DUCT SUPPORTS PER SMACNA, IMC 603 -10. 1.7 ATTACH DIFFUSERS AND GRILLES TO T -BAR GRID PER WA STATE & LOCAL CODES. 1.8 BALANCING DAMPERS ARE TO BE INSTALLED ON ALL BRANCH DUCTS OR DIFFUSERS. INSULATION 2.1 INSULATE OR LINE DUCTWORK PER WA. STATE ENERGY AND MECHANICAL CODES. 2.2 INSULATE REFRIGERANT & CONDENSATE PIPING PER STATE & LOCAL ENERGY CODES. GENERAL CONTRACTOR 3.1 GENERAL CONTRACTOR TO PROVIDE AND CUT OPENINGS FOR ALL ROOFTOP CEILING, FLOOR, AND WALL PENETRATIONS, INCLUDING WEATHERPROOF SEALING AND FIRE PROOF LINING PER IMC & IBC. 3.2 GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATION AND DIMENSIONS WITH ERL BEFORE FRAMING OPENINGS. 3.3 GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING, AND PAINTING AS REQUIRED FOR MECHANICAL WORK. 3.4 GENERAL CONTRACTOR TO PROVIDE ADEQUATE STRUCTURAL SUPPORT AS REQUIRED FOR MECHANICAL WORK. 3.5 GENERAL CONTRACTOR TO PROVIDE ADEQUATE ENGINEERING AS REQUIRED FOR MECHANICAL WORK. 3.6 GENERAL CONTRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL MECHANICAL EQUIPMENT. 3.7 GENERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY ERL PROVIDE ALL CANT STRIPS AND CURB INSULATION, AND SEAL AGAINST LEAKS. 3.8 GENERAL CONTRACTOR TO PROVIDE ALL CUTTING AND PATCHING OF T -BAR CEILING AS REQUIRED FOR HVAC INSTALLATION. 3.9 GENERAL CONTRACTOR TO PROTECT ALL OPENINGS THROUGH FLOORS PROVIDED FOR DUCTWORK INSTALLATION IN ACCORDANCE WITH TABLE 601 OF INTERNATIONAL BUILDING CODE, WHERE REQUIRED BY SECTION 707 OF IBC. ELECTRICAL 4.1 ERL TO INSTALL ALL LOW VOLTAGE CONTROL WIRING, CONDUIT WILL BE PROVIDED BY ELECTRICAL CONTRACTOR. 4.2 ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL CONNECTIONS, DISCONNECTS, AND STARTERS FOR MECHANICAL EQUIPMENT. 4.3 ELECTRICAL CONTRACTOR TO VERIFY EQUIPMENT SIZES, LOADS AND LOCATIONS WITH ERL MECHANICAL PLAN AND WITH FIELD CONDITIONS. 4.4 ELECTRICAL CONTRACTOR TO INTERLOCK BATHROOM EXHAUST FANS WITH LIGHT SWITCH. 4.5 ERL TO PROVIDE 7 -DAY NIGHT SETBACK, PROGRAMMABLE TYPE T -STAT WITH CAPABILITY OF 5 °F DEADBAND. 4.6 ERL TO VERIFY FINAL LOCATION OF THERMOSTAT WITH CUSTOMER. 4.7 ELECTRICAL CONTRACTOR TO PROVIDE ELECTRICAL GCFI OUTLET WITHIN 25 FT OF EACH PIECE OF MECHANICAL EQUIPMENT. PLUMBING 5.1 PLUMBING CONTRACTOR TO FURNISH AND INSTALL ALL GAS PIPING FOR MECHANICAL EQUIPMENT PER CODE. 5.2 PLUMBING CONTRACTOR OFFSET VENTS 10 FEET MINIMUM FROM ALL HVAC FRESH AIR INTAKES OR 2' ABOVE HIGHEST POINT OF INTAKE, IMC 401.5.1. 5.3 CONDENSATE DRAINS FROM RTU BY ERI TO DRAIN WITHIN 12" OF UNIT. CONDENSATE DRAINS FOR AIR HANDLERS BY PLUMBER. ENERGY CODE COMPLIANCE 6.1 AT A MINIMUM, EACH FLOOR IS TO BE CONSIDERED A SEPARATE ZONE. VERIFY THERMOSTATIC CONTROL FOR EACH ZONE AS INDICATED ON PLANS. 6.2 OUTSIDE AIR INTAKES, EXHAUST OUTLETS AND RELIEF OUTLETS SERVING CONDITIONED SPACES SHALL BE EQUIPPED WITH DAMPERS WHICH CLOSE AUTOMATICALLY WHEN THE SYSTEM IS OFF OR UPON POWER FAILURE, PER WSEC SEC. 1412.4.1. 6.3 AIR ECONOMIZERS WHERE REQUIRED BY CODE ARE INDICATED BY THE EQUIPMENT SCHEDULE AI 100% CAPABILITY, CONTROL AND OPERATION OF THE ECONOMIZER SHALL COMPLY WITH WSEC SEC. 1423. MECHANICAL CODE COMPLIANCE 7.1 WHERE REQUIRED PROVIDE AUTOMATIC SHUTOFF ACTIVATED BY SMOKE DETECTORS IN EACH SYSTEM DELIVERING HEATING OR COOLING AIR IN EXCESS OF 2000 CFM. DETECTORS SHALL BE LOCATED IN THE MAIN RETURN AIR PER IMC 606. WA2004111 U 0 w w w w co N 0 NUT PUBLISHED. ALL RIGHTS RESERVED. THE DRAWING AND SPECIFICATIONS, IDEAS; DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF EVE- RGREEN REFRIGERATION INC. NO PART THEREOF SHALL BE REPRODUCED, COPIED, ADAPTED, DISC- LOSED OR DISTRIBUTED TO OTHERS, SOLD, PUB- LISHED OR OTHERWISE USED WITHOUT THE PRIOR WRITTEN CONSENT OF AND APPROPRIATE COMPEN- SATION TO EVERGREEN REFRIGERATION INC. VISUAL CONTACT WITH THE ABOVE DRAWINGS OR SPECIFIC- ATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. OD 0 N N 0 Q w • ❑ ❑ ❑ REVISIONS NO DATE 02/15/08 w o0 Q co 0 c O . co D ti ITEM OWNER REV. DRAWING DATE: 02/12/08 DWG. BY: GN CHK. BY: AL /DP JOB NO.: 80026 DWG. FILE: 80026M4- 3. Fans are to to be switched on with the lights 4. Fan to be equipped with a Warren 3 kW electric duct heater that is to be activated with an inline ductstat 1. Provide with curb and back draft damper 2. Fan to be interlocked with the equipment it is venting 3. Provide with motor starter 4. Fan to be switched on by others. 5. Fan to run continuously M1 0F5 3) N N 1- :') N 3) Z O Z Li J w Z 3 Z t p NI 0 3) X PAT PUBLISHED. ALL RIGHTS RESERVER THE DRAWING AND SPECIFICATIONS, IDEAS. DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF EVE - ReREEN REFRIGERATDON INC. NO PART THEREOF SHALL BE REPRODUCED, COPIED, ADAPTED, DISC- LOSED OR DISTRIBUTED TO OTHERS, SOLD, PUB- LISHED OR OTHERWISE USED WITHOUT THE PRIOR WRITTEN CONSENT OF AND APPROPRIATE C 'EN- SATIUN TO EVERGREEN REFRIGERATION INC. VISUAL CONTACT WITH THE ABOVE DRAWINGS OR SPECIFIC- ATIONS SMALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. v! W HVAC WAREHOUSE FLOOR PLAN 18375 OLYMPIC AVE S TUKWILA, WA 98188 N 1V1 REVISIONS NO DATE ITEM /1\ 02/15/08 OWNER REV, ® 02/19/08 GAS PIPING ® 03/05/08 Scale rev X LI DRAWING DATE: 02/14/08 Li DWG. BY: GN CHK. BY: AL /DP JOB NO.: 80026 DWG. FILE: 80026M4— OF 3 "(EX (5) ! MATCH LINE SEE M5 TING) MATCH LINE SEE M5 1" (6') NEW (STING) 6 EF- 10" '10" 1 10 10" 10" m v EF f�l 4 ® �I H 10" 10" 10" Mai 10" IR (O I 2 G G G 1-1/2"(32') W 1 "( ®/ NEW 1- 1/2 "(58') V NEW 1-1/4" (31') NEW RTU -2 15 TON s NEW I I r G ' RTU -1 40 TON NEW SCALE : 1/16" = 1' -0" 250 MBTU ‘''. 1 250 MBTU 7� 0 MBTU `� / 57,000 SF /200 = 285 0CC r L. 1 137 1 OFFICE SEE M2 AND M3 FOR FLOORPLAN MANUF. FLOOR HIGHFLYING 8% 1- 1/4"(16') NEW "N 1"(55') 2 -1/2" (EXISTING) 1" 9' NEW 1"(42') NEW HVAC WAREHOUSE FLOOR PLAN 1-4 I ®25Q MB NEW ® 1 "(38')® NEW C J n !IR 250 MBTU 'I ! i ■ i ■ -rJIZ' I I.I I f F 1"(6') NEW HUH Il1/ii MOH 1-1/4%58') NEW 1- 1/4"(58' NEW IR - 0 ICU 1"(70') NEW IR 1 "(77') NEW \, 1"') 1 "(77') A NEW - 114 (12 1.. 3' J NEW LI SHIPPING &RECEIVING [1381 6,449 SF/200 =32 0CC 175 MBTU 12 1 \ Q R A -9 ®175 MBTU F J r 6700/5000 =2 0C INVENTORY 220 CFM OF FICE SF I 139 I ED F . ,. ;13; 1 - t= ( 7 1 1 _._._._._.app,; EF 12 EF CODE AP PROVe v CO MPLIANCE MAR ?Qf1t P City Of T NG QMSION MAID 10 2008 PERMIT CENTER U x w w 0) CO co N co 0 1 CO Cfl 0 N D0 0) Z 0 Z ,tt 11 Z 3 Z Z 3 1 x) 3 Z D : ` AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF EVE- RGREEN REFRIGERATION INC. NO PART THEREOF SHALL BE REPRODUCED, COPIED, ADAPTED, DISC- LOSED OR DISTRIBUTED TO OTHERS, SOLD, PUD- LISHED OR OTHERWISE USED WITHOUT THE PRIOR WRITTEN CONSENT OF AND APPROPRIATE COMPEN- SATION TO EVERGREEN REFRIGERATION INC. VISUAL CONTACT WITH THE ABOVE DRAWINGS OR SPECIFIC- ATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. V, W HVAC WAREHOUSE FLOOR PLAN 18375 OLYMPIC AVE S TU KW1 LA, WA 98188 DUST ida REVISIONS NO DATE ITEM ,4\ 02/15/08 ! OWNER REV. 02/19/08 GAS PIPING /3\ 03/05/08 Scale rev. DRAWING DATE: 02/14/08 W DWG. BY: GN CHK. BY: AL /DP JOB NO.: 80026 DWG. FILE: 80026M5— f F 5 L I SCALE : 1/16" =1 / 1 , ,2, 3 -� - IFS -=1- 2-2 ❑ 175 MBT 2 -6 175 MBTU —17-5 M BTU Iii ®, 4 '�' ►`I ,1 F I TAKE H ASSEMBLY AREA 17,976 SF /200 =90 0CC 1 "(57') / NEW \ -, ' /� 175 MB 2" EXISTING 1"(17') NEW G i 3/4" 46' 3/4 "(2 'i NEW NEW A 175 MBTU 3 "(EX HVAC WAREHOUSE FLOOR PLAN 4.\ f (5 ! MATCH LINE SEE M5 STING) R r L MATCH LINE SEE M5 1 TLI REVIEWE e: CODE COMPLIANCE APPROVEr MAR 2 ?IX *, qty Of Tukw ls:. B . ILDING n r /SIO n CE ED MAR 10 2008 PERMI I I F ✓�.. � � T R CENTE= v_ NOT PUBLISHED. ALL RIGHTS RESERVED. THE DRAWING AND SPECIFICATIONS, IDEAS, DESIGNS