HomeMy WebLinkAboutPermit PG08-078 - WESTFIELD SOUTHCENTER MALL - SHARKY'S WOODFIRE MEXICAN GRILLSHARKY'S WOODFIRE MEXICAN GRILL 2600 SOUTHCENTER MALL PG08-078 Parcel No.: 6364200010 Address: Suite No: CetyIllf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PLUMBING /GAS PIPING PERMIT 2600 SOUTHCENTER MALL TUKW Permit Number: Issue Date: Permit Expires On: PG08 -078 05/14/2008 11/10/2008 Tenant: Name: Address: Owner: Name: Address: SHARKY'S WOODFIRE MEXICAN GRILL 2600 SOUTHCENTER MALL FC -2 , TUKVVILA WA WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD CA Contact Person: Name: RICHARD HERMAN Address: 6009 MELROSE AV , LOS ANGELES CA Contractor: Name: WESTWOOD CONTRACTORS INC. Address: 200 S 333RD ST #244 , FEDERAL WAY WA Contractor License No: WESTWCI088BF Phone: Phone: 323 465 -7066 Phone: 206 661 -0800 Expiration Date: 09/11/2008 DESCRIPTION OF WORK: INSTALL PLUMBING AND GAS PIPING FOR NEW RESTAURANT IN FOOD COURT. Value of Plumbing /Gas Piping: Fees Collected: $30,000.00 $806.00 Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 FIXTURE TYPE AND QUANTITY Plumbing Bathtub or combination bath/shower 0 Bidet 0 Clothes washer, domestic 0 Dental unit, cuspidor 0 Dishwasher, domestic, with independent drain 0 Drinking fountain or water cooler (per head) 0 Food -waste grinder, commercial 0 Floor drain 3 Shower, single head trap 0 Lavatory 0 Wash fountain Receptor, indirect waste 5 Sinks 5 Urinals 0 Water Closet 0 0 Plumbing (cont.) Building sewer and each trailer park sewer 0 Rain water system - per drain (inside bldg) 0 Water heater and /or vent 1 Industrial waste treatment interceptor, including its trap and vent, except for kitchen type grease interceptors 0 Repair or alteration of water piping and/or water treatment equipment 0 Repair or alteration of drainage or vent piping 0 Medical gas piping system serving (1 -5) inlets /outlets for a specific gas 1 Medical gas piping (6 +) inlets /outlets 1 Gas Piping Gas piping outlets (0 -5) 5 Gas piping outlets (6 +) 0 * *continued on next page ** doc: UPC -10/06 PG08 -078 Printed: 05 -14 -2008 City ofTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: PGO8 -078 Issue Date: 05/14/2008 Permit Expires On: 11/10/2008 Permit Center Authorized Signature: Lait_ RJA. Date: T- f 1 -0 O I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does of presume to give authority to violate or cancel the provisions of any other state or loc laws egulating construction or the /performanc: of work. I am authorized to sign and obtain this plumbing /gas piping permit. Signature: Print Name: NG / io2L' Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -10/06 PG08 -078 Printed: 05 -14 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS 2600 SOUTHCENTER MALL TUKW SHARKY'S WOODFIRE MEXICAN GRILL Permit Number: Status: Applied Date: Issue Date: PG08 -078 ISSUED 03/13/2008 05/14/2008 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: ** *PUBLIC WORKS DEPARTMENT CONDITIONS * ** 14: Waste line shall connect to landlord provided common grease waste pipe that terminates into a common existing grease interceptor located outside the building. * *continued on next page ** doc: Cond -10/06 PG08 -078 Printed: 05 -14 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Date: ordinances governing or local laws regulating doc: Cond -10/06 PG08 -078 Printed: 05 -14 -2008 • • CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hup://www.c.i. tukwitu.'it a. us Building Permit No. 008 - j .z. Mechanical Permit No. _ ' Plumbing /Gas Permit No. P(70q OICZ Public Works Permit No. Project No. 12O9_O5r) (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION /� ,[ King Co Assessor's Tax No.: 0 ("Q% 0 - 0016 Site Address: 1600 i01).4-4 C'a &TtiZ IMAL-L Suite Number: F(.- 2 Floor: 2 Tenant Name: ,C'ijA(2.0 •i'S L)Q o ApRE mo<tcA N.1 GRJ (L New Tenant: [i' Yes ❑ .. No Property Owners Name: (,J6S E-lELA CO/LP Mailing Address: 1 CO 1 C31 LS h 1 R 01. V2Y Lg./ LOS ANGE Lee CA City State oo2s Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: RI c4441,, 146ruAAA Mailing Address: 600 ELII.0%. AVE - Day Telephone: (l2.1 46S_ — ANGELGS Cd 416) 3 A E -Mail Address: (11-1 e wka C.rrl . Cd1M City \ State Zip Fax Number. 14 " 606(, GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: KI.OT a - -LECT / Mailing Address: City Day Telephone: Fax Number: - Expiration Date: Contact Person:_ —_ E -Mail Address: Contractor Registration Number: State Zip ARCHITECT OF RECORD —All plans must be wet stamped by Architect of Record Company Name: Ke\i. a UTTS Mailing Address: 124 vAGecOACN (-2.Am aL(,L. 011‘101,.1 I CA q1361 State Zip Day Telephone: (818 etgl - 4 212 E -Mail Address: Fax Number:- (b 1 U 99 9 - 432.1 Contact Person: ILI. lei 13 U 17S City ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: city Day Telephone: Fax Number: Contact Person: E -Mail Address: 1 )u Linn 3 -_nOi, . dnc It-- ,ii.cti 1_1111( hh State Zip I'aec 1 of tt PLUMBING AND GAS PIPING PERMIT INFORMATION — 206- 431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: N Q [ S� t'_67366 Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: - Fax Number: Contractor Registration Number: - Expiration Date: 00 Valuation of Plumbing work (contractor's bid price): $ 2S, 000 - Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): T€ 4z j4T RMpticuc: '- T W act/ 4z z }pup Aft SAC.€ x'02 AU 88 ( S. 6-- 'Pace AT l\ QUIT Al' 146- CtriL4 cEmTpo tM. su Building Use (per lnt'l Building Code): Occupancy (per Int'I Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and /or gas piping outlets being installed and the yuant'ty below: Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath /shower `^ Drinking fountain or water cooler (per head) — Wash fountain _ Gas piping outlets Bidet .,,, Food -waste grinder, commercial _ Receptor, indirect waste s _ Clothes washer, domestic Floor drain 3 Sinks S - — Dental unit, cuspidor — Shower, single head trap — Urinals — — Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer — Rain water system per drain (inside building) Water heater and /or vent I Additional medical gas inlets /outlets six or more — Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and /or water treating equipment ( Repair or alteration of drainage or vent piping I Medical gas piping system serving one to five inlets /outlets for specific gas gpp6cxunu, 1-01111, AN;i,,,n..?, nu Lmc's,1_0 , I; �„�, Apphcnwn do, i, t1- '1 :006 hh Page 5 of 6 Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING Signatur R AUTHOR ED AGEN Print Name: BRA : :70 >>c—o.€ Mailing Address: 633 Sa Hihc$.t>� T�'4 , 1 Day Telephone: "L — - 4,07 / City State Zip Date Application Accepted: Date Application Expires: Staff Initials: 0b ;1,121Oil 171 I(2- -� jr: Q :WpplicationsWorms•Applications On Lin&J -2006 - Permit Application.doc Revised: 9 -2006 bh Page 6 of 6 Parcel No.: Address: Suite No: Applicant: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT 6364200010 2600 SOUTHCENTER MALL TUKW SHARKY'S WOODFIRE MEXICAN GRILL Permit Number: Status: Applied Date: Issue Date: PG08 -078 ISSUED 03/13/2008 05/14/2008 ar Receipt No.: R08 -01852 Initials: LAW User ID: 1632 Payee: Payment Amount: Payment Date: Balance: $60.00 05/29/2008 03:17 PM $0.00 WESTWOOD CONTRACTORS TRANSACTION LIST: Type Method Descriptio Amount Payment Cash 60.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLUMBING - NONRES 000.322.103.00.0 60.00 Total: $60.00 2967 05/29 9711 TOTAL 60.00 doc: Receiot -06 Printed: 05 -29 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: PG08 -078 Address: 2600 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 03/13/2008 Applicant: SHARKY'S WOODFIRE MEXICAN GRILL Issue Date: Receipt No.: R08 -01615 Payment Amount: $723.25 Initials: WER Payment Date: 05/14/2008 08:56 AM User ID: 1655 Balance: $0.00 Payee: WESTWOOD CONTRACTORS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 144559 723.25 ACCOUNT ITEM LIST: Description Account Code Current Pmts GAS - NONRES PLUMBING - NONRES 000.322.103.00.0 92.00 000.322.103.00.0 631.25 Total: $723.25 doc: Receiot -06 Printed: 05 -14 -2008 i City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: PG08 -078 Address: 2600 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 03/13/2008 Applicant: SHARKY'S WOODFIRE MEXICAN GRILL Issue Date: Receipt No.: R08 -00740 Initials: User ID: Payee: JEM 1165 Payment Amount: $82.75 Payment Date: 03/13/2008 10:48 AM Balance: $363.25 RS HERMAN ARCHITECTS, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 10402 82.75 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES PLUMBING - NONRES 000/345.830 82.00 000.322.103.00.0 .75 Total: $82.75 9083 03/13 9730 TOTAL 82.75 doc: Receiot -06 Printed: 03 -13 -2008 INSPECTION NO. INSPECTION RECORD Retain a copy with permit /Jog-gs PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Project. \)&7 OWL , 4' S fr i lat 64// Type of Inspection: 5 »»! / �...�' i__S Address: 6e20 tif /t d41/ Date Called. Special Instructions: - Date Wanted: Requester: Phone No: Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: El$60.00 REINSPECTION F E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: %. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PEjtMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Proje t: 1 )rA r kli s lk)() i f( Type of Inspection: c-,' N A 1 P kmak 6- Address: 2, _too 0 M A Il Date Called: Special Instructions: Datente �� a�n` �' Requester: Pho a No: brib l-%-Aq Co -9 6 S'b ❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS: p 4 6 1 j( b.), t.--7A14- 4-p fihne gekett_F-16(3 bra, e,.. (leif4 . /- ;(10, LIOt . c A IA c$,e- C..Ns p.4 w 4-k ceL -7Z, 5, / : , -.. / -... Inslbector: El $60. 0 Date 6- r2 . EINSPECTION FE REQUIRED. Prior to inspection, fee must be pai . . 6300 Southcenter lvd., Suit 100. Call to schedule reinspection. Receipt o.: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 /V 0E -92f Project: clear/9Y Type of Inspection: 4.0 PFZ. wag" L Date Called: Special Instructions: Date Wanted: 7 --0 —.o & 'a.n p.m. Requester: Gets FF•‘ /cf Phone No: 2IApproVed per applicable codes. Corrections required prior to approval. COMMENTS: 71,1Y8( 4 Ad /)<0G.."1 �7! C d 4fC /p.1 f Inspector: Date: El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit !'(rofs -07cei PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: r 9'f�l } Type of Inspection: (Z2 "n I /Vri/Jr") Address: 2.00 M=II Date Called: P..-' 1isf 61.- A'r — o‹ Special Instructions: Date Wanted: S 3 '7- -8 a.m. pm. Requester: Phone No: if (7- 7c71 -1y7 © Approved per applicable codes. Corrections required prior to approval. COMMENTS: P..-' 1isf 61.- A'r — o‹ . %'1- Ret' f , "oin f��-- 'c�° /'orid 617, !'J 4 ,( Ptfx L (i 7r4,,-\ , xis, sPerfi.<h Inspector: Date: 76, ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: iP &o o 7r 1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. i IL (206)431 -3670 h Project: S 1 k Type of Inspectio %� Address: y Date Called: J Special Instructions: Date Wanted S7 / � �` p.m. Requester: Phone NoQ� -y U 7 ,4 �� /-� X77, Approved per applicable codes. Corrections required prior to approval. COMMENTS: pA 55 -11/y 1....41.41....41.4","" 44"� aL r Q1 -s1 p,,,/ Ni. 1 N.. /4-, ref 4-- N(,/Z- G >Pf:</ P;(4.- Th sl. Ile"( r f ry,, e CI Inspector: Date: ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: \I P.L.E. BACKFLOW TESTING Phone: 253 297 -4387 www.backflowtester.com Fax: 253 864 -0107 P.O. Box 9199 * Covington, Washington 98042 ID/ errs Backflow Test Report Name: S-h Kil- 1J oo raze- AV. 6 r 1 /1 Passe • X. Failed Service Address: 2(0 06 s©u c of -(I - ' . SpACF I L4 LJ4 Backflow Location: 4.60u E .5Ji Si d k A-T ► 6k ro 6 Cross Connection Control for: ,bier lc Type Assembly: /2J Manufacturer: (,, h Model: t /nasaTSize: /IA / Serial No: / /3! Z4. Initial Test Result RPBA Line Pressure 7 % No. 1 Check Valve. /©' 3 psid Relief Valve Opened- 'f f psid Buffer Amount. psid Leaked Leaked No. 1 Check: Closed Tight /a t No. 2 Check: Closed Tight i 1 1 Minimum Air Gap: Ye No Passed Test es __— No DCVA Line Pressure: No. 1 Check: Closed Tight No. 2 Check: Closed Tight Passed Test Yes No Leaked Leaked PVB /SPVB Line Pressure: Air Inlet: Opened psid Failed to open Check Valve: psid Leaked Passed Test Yes No AIR GAP: Minimum Separation Yes No Pipe Gap Test Equipment: Make. 4- Model:: ?C Serial#: 6131603 Accuracy Verification Date. /.2 -4' O Repairs/Remarks: Test After Repairs RPBA Line Pressure. No. 1 Check Valve- psid Relief Valve Opened- psid Buffer Amount. psid No. 1 Check: Closed Tight Leaked No. 2 Check: Closed Tight Leaked Minimum Air Gap: Yes No Passed Test Yes No DCVA Line Pressure: No. 1 Check: Closed Tight No. 2 Check: Closed Tight Passed Test Yes Leaked Leaked No PVB /SPVB Line Pressure. Air Inlet: Opened psid Failed to open Check Valve. psid Leaked Passed Test Yes No ASSEMBLY STATUS: New Existing PROPERLY INSTALLED: Yes X_ No I CERTIFY THIS RE Signature. Print Name. Phone. Initial Test: Cert# Michael J. if mgs RUE PRINT Ce11253 97 387 B 142 Date. j Repairs. Date. Repaired Test. Date Cert # UBI 601 040 690 r ' cJ, )//4- P.L.E. BACKFLOW TESTING Phone: 253 297 -4387 www.backflowtester.com Fax: 253 864 -0107 P.O. Box 9199 * Covington, Washington 98042 phombi E „/0 ass Backflow Test Report Name:Sr. ?S /flr c 611-7/ Service Address: 2C O() J ©o cfn)Tf, 07,08 Backflow Location: &lc k loom y s.4 Cross Connection Control for: Bf iJf2A. 6' C u fJ ml.✓1`'” Type Assembly: I'PB' Manufacturer: 41 Model: 6 • ! 1 Size: /Z" Serial No: 4( c/4 % 7 PL E Failed V 7 At.i /, M41 Initial Test Result RPBA Line Pressure. No. 1 Check Valve- psid Relief Valve Opened: 1 ' ? psid Buffer Amount. psid No. 1 Check: Closed Tight _ID Lt t Leaked No. 2 Check: Closed Tight C -.Te Leaked Minimum Air Gap: Yes'No Passed Test Yes No DCVA Line Pressure: No. 1 Check: No. 2 Check: Passed Test Closed Tight Closed Tight Yes No Leaked Leaked PVB /SPVB Line Pressure. Air Inlet: Opened Check Valve. Passed Test Yes psid Failed to open psid Leaked No AIR GAP: Minimum Separation Yes No Pipe Gap Test uipment: Make: 4W Model: 6 Serial #. c7 /3y� ©3 Accuracy Verification Date. /oZ - /cal— © 7 Repairs/Remarks: Test After Repairs RPBA Line Pressure- No. 1 Check Valve. psid Relief Valve Opened. psid Buffer Amount psid No. 1 Check: Closed Tight Leaked No. 2 Check: Closed Tight Leaked Minimum Air Gap: Yes No Passed Test Yes No DCVA Line Iessure: No. 1 Check: Closed Tight No. 2 Check: Closed Tight Passed Test Yes Leaked Leaked No PVB /SPVB Line Pressure: Air Inlet: Opened psid Failed to open Check Valve: psid Leaked Passed Test Yes No ASSEMBLY STATUS: New Existing PROPERLY INSTALLED: Yes No I CERTIFY THIS ' T O BE TRUE PRINT Signature. Print Name. Michae J. Gi • gs Phone. Cell 253 297 -4387 Initial Test. Cert# B142 !' Repairs. Date. Repaired Test- Date. Cert # Date. 7--.i3-20e- UBI 601 040 690 PLAN VIRACOUTING SLIP ACTIVITY NUMBER: PG08 -078 DATE: 05 -15 -08 PROJECT NAME: SHARKEY'S WOODFIRED MEXICAN GRILL SITE ADDRESS: 2600 SOUTHCENTER MALL FC -2 Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter #� X Revision # 1 After Permit Issued DEP RTMENTS: Bu dig ion Public Works Fire Prevention Structural n n Planning Division Permit Coordinator n D T RMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 05-20 -08 Not Applicable Permit Center Use Only . . INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 06 -17 -08 Approved Approved with Conditions n Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2-28-02 • • PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP DEPARTMENTS: 18 B �dng "Divt ikon Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 03-18 -08 Not Applicable INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: ❑ No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DUE DATE: 04 -15 -08 DATE: Peirntit�Ce�ferUse Onty, CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28-02 • • City of Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila; Washington 98188 Phone: 206 - 431 -3670 Fax: 206431-3665 Web site: http:/lwwW,ci.tulaWla.wa.us Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: - /5 - U 8 _ Plan Check/Permit Number: a $ — 07 d ❑ Response to Incomplete Letter # 0 Response to Correction Letter # [r Revision # f after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: LS/4 r kq1.5 _ Wded 7 f%?eiL/�Gf —i Project Address: 06192) ti /e,' %�'? .// pt —< 73;406 1 Contact Person: /%?la„ -.i € e� cvY�Q_ Phone Number: Summary of Revision: / I.?? 6 r C. l iiy-e( _c m m � Po . / ' add I re. v; etx ,. h-e2.4., dr^; — h O a de 7 �.,�f cam-) 'vim 4.7 p°i 1/ of ' ca7-7/7 6 I-E7 / a/ // nve s- � c7 Jed* -- l�4 ? J /0ri - �Dl - -Q� eU. )14,t rQ o-r s_; lo(� e K • -�c;�e i i 7 ; — (-02- —X07/ Sheet Number(s): P� . / p/./ "Cloud" or highlight all areas of revision including date o Received at the City of Tukwila Permit Center by: Entered in Permits Plus on S- (5`30.441 a applications\forms- applications on Iine revision submittal Created: 8 -13 -2004 .L iEp r ri JKIAIP MAY 1 5.2006 eLHMl r CENTER Look Up a Contractor, Electricjin or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. License Information License WESTWCI088BF Licensee Name WESTWOOD CONTRACTORS INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601011419 Ind. Ins. Account Id Business Type CORPORATION Address 1 951 W 7TH STREET Address 2 ATTENTION: LILY SEGURA City FORT WORTH County OUT OF STATE State TX Zip 76102 Phone 8178773800 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 1/6/1992 Expiration Date 9/11/2008 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date BENDA, ROBERT D 01/01/1980 06/11/2002 CHASE, DAVID E 01/01/1980 06/11/2002 BENDA, JOAN M 01/01/1980 06/11/2002 • Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date TRAVELERS CAS & Until Page 1 of 3 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= WESTWCI088BF 05/14/2008 REVISION I LANDLORD PLAN CHECK COMMENTS 3 -17 -08 I ISSUED FOR BIDDING 2600 SOUTHCENTER MALL, SPACE # FC -2 TUKWILA, WASHINGTON ISSUED FOR CONSTRUCTION ISSUED FOR: DESIGNED BY: - DRAWN BY: - K<<<<<<<< ISSUE A DATE HEALTH DEPARTMENT SUBMITTAL n 03 -29 -08 PERLIMINARY SUBMITTAL A PLAN DEPARTMENT SUBMITTAL & WESTFIELD FINAL SUBMITTAL n JOB NUMBER: 07936 KENN BUTTS A.I.A. Butts / SCALE: AS NOTED SHEET NUMBER: P0.1 Kenneth L. Architect 124 STAGECOACH ROAD BELL CANYON, CA. 91.307 TEL. (818) 999 4272 FAX. (818) 999 4321 Y V KULKARNI, P.E. (MECHANICAL AND ELECTRICAL) 39371 SPANISH BAY PLACE DAVIS, CA 95616 E -MAIL YASHAVANT@COX -NET FOR PROJECT COORDINATION CONTACT PROJECT MANAGER KIM KIMIAGAR 310 576 1553 PHONE 310 576 1569 FAX REVISION I LANDLORD PLAN CHECK COMMENTS 3 -17 -08 I ISSUED FOR BIDDING ISSUED FOR PERMn ISSUED FOR CONSTRUCTION ISSUED FOR: DESIGNED BY: - DRAWN BY: - K<<<<<<<< ISSUE A DATE HEALTH DEPARTMENT SUBMITTAL n 03 -29 -08 PERLIMINARY SUBMITTAL A PLAN DEPARTMENT SUBMITTAL & WESTFIELD FINAL SUBMITTAL n JOB NUMBER: 07936 FILE #: P0.1.DWG SHEET TITLE: PLUMBING SYMBOLS NOTES & ABBRV SCALE: AS NOTED SHEET NUMBER: P0.1 B0 - 60 - L0 31da 20 11 - ZOI 20- 90 -20I ISSUED FOR APPROVAL ISSUED FOR PLAN CHECK ISSUED FOR BIDDING ISSUED FOR PERMn ISSUED FOR CONSTRUCTION ISSUED FOR: DESIGNED BY: - DRAWN BY: - CHECKED BY: - REVIEWED BY: - DATE: 03.29.2008 JOB NUMBER: 07936 FILE #: P0.1.DWG SHEET TITLE: PLUMBING SYMBOLS NOTES & ABBRV SCALE: AS NOTED SHEET NUMBER: P0.1 • LANDLORD PROVIDED A TENANT FIRE SERVICE MAIN WITH BRANCH PIPING STUBBED INTO EACH TENANT'S SPACE. LANDLORD'S SPRINKLER SYSTEM IS DESIGNED PER ORDINARY HAZARD GROUP 2 AND THE LATEST REQUIREMENTS OF NFPA -13. NO ISOLATION VALVES WILL BE PROVIDED OR PERMITTED. • TENANT SHALL CONNECT A FIRE SPRINKLER SYSTEM TO LANDLORD'S SPRINKLER SYSTEM WITHIN THE DEMISED PREMISES USING APPROVED MECHANICAL FITTINGS. TENANT SHALL PROVIDE AND INSTALL ALL BRANCH PIPING AND SPRINKLERS REQUIRED TO COMPLETE THE SPRINKLER SYSTEM WITHIN THE TENANT SPACE. TENANT'S SPRINKLER SYSTEM DESIGNS SHALL BE BASED UPON THE REQUIREMENTS OF THE STATE OF WASHINGTON, CITY OF TUKWILA FIRE DEPARTMENT. TENANT SHALL ENGAGE THE SERVICES OF A LANDLORD PREFERRED FIR SPRINKLER CONTRACTOR TO DESIGN, PERMIT AND INSTALL TENANT'S FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH THE BASE BUILDING DESIGN SPECIFICATIONS. SPRINKLER LAYOUT AND PIPE SIZING SHALL BE HYDRAULICALLY DESIGNED ACCORDING TO ORDINARY HAZARD GROUP 2 AND THE LATEST REQUIREMENTS OF NFPA --13. • ALL SPRINKLER HEADS IN THE FORWARD SELLING AREA ARE TO BE CONCEALED POP -OFF COVER TYPE. • ALL SUPPORTS SHALL BE FROM STRUCTURAL BEAMS AND JOISTS, NOT FROM FLOOR OR ROOF DECK ABOVE. • TENANT'S CONTRACTOR SHALL INSTALL AN INSPECTORS TEST CONNECTION, PIPED TO A FUNNEL DRAIN, (WITH WET TRAP), MOUNTED 3'--0" A.F.F. INSTALL A 1" CORROSION RESISTANT SHUT -OFF VALVE. • TENANT SHALL INSTALL A VANE TYPE WATERFLOW DETECTOR IN THE MAIN SPRINKLER LINE IMMEDIATELY AFTER CONNECTION TO THE LANDLORD'S MAIN, WHICH IS CONNECTED TO THE LANDLORD'S FIRE ALARM SYSTEM. LANDLORD FIRE PROTECTION NOTES 1 ALL WORK SHALL COMPLY WITH THE 2006 UNIFORM PLUMBING CODE, AND LOCAL CODES. 2. ALL CLEAN OUTS SHALL BE ACCESSIBLE AND INSTALLED PER 2006 UNIFORM PLUMBING CODE AND UNIFORM PLUMBING CODE SECTION 707 & 719. 3. ALL WATER FAUCETS SHALL BE PROVIDED WITH CODE- APPROVED FLOW RESTRICTORS. 4. SLOPE OF SANITARY SEWER PIPES SHALL NOT BE LESS THAN 2% UNLESS OTHERWISE INDICATED AND APPROVED BY THE AUTHORITY HAVING JURISDICTION. 5. ALL DOMESTIC HOT WATER PIPING SHALL BE INSULATED AS REQUIRED BY THE ENERGY CODE. 6. ALL PIPING TO BE SEISMICALLY BRACED TO PREVENT SWAYING PER LOCAL AND STATE BUILDING CODE. 7. PROVIDE SNAP-ON TYPE INSULATION ON TRAPS AND HOT WATER PIPING FOR SINKS AND OTHER A.D.A. ACCESSIBLE FIXTURES. 8. DURING CONSTRUCTION, PROVIDE MECHANICAL PLUGS IN OPEN DRAINS TO PREVENT DAMAGE TO LOWER FLOORS. ALL WATER PIPING LOCATED ABOVE CEILING, REQUIRING TEMPORARY OR PERMANENT CAPPED CONNECTIONS, SHALL BE PROVIDED WITH LINE -SIZE SHUTOFF VALVES. 9. ROUGH -INS, CONNECTIONS AND TERMINATION OF PLUMBING WORK SHALL BE SEQUENCED IN COORDINATION WITH THE PROJECT SCHEDULE THE ARCHITECT, AND THE OWNERS OTHER CONTRACTORS AND VENDORS. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS OF FIXTURES AND APPLIANCES. 10. A MINIMUM 1/2" CLEARANCE SHALL BE PROVIDED AROUND PIPES AT ALL PENETRATIONS THROUGH WALLS AND ROOF. THE GAP SHALL BE PACKED TIGHTLY WITH LOOSE, LIGHTWEIGHT INSULATION THROUGH NON RATED WALLS, AND APPROVED U.L. LISTED FIRE SAFING MATERIAL RATED WALLS TO MATCH WALL RATING. 11. PROVIDE AND INSTALL ACCESSIBLE WATER HAMMER ARRESTERS OF REQUIRED SIZE AND LOCATION. MANUFACTURER AND MODEL NUMBERS SHALL BE PER SPECIFICATIONS. 12. PROVIDE ACCESS PANELS IN WALLS FOR SHUTOFF VALVES, TRAP PRIMERS AND WATER HAMMER ARRESTERS. CONTRACTOR IS ADVISED THAT ITEMS REQUIRING ACCESS SHALL NOT BE LOCATED ABOVE THE AREAS OF GYPSUM BOARD CEILING WITHOUT CONSENT OF ARCHITECT. SUBMIT PROPOSED ACCESS PANEL LOCATIONS TO ARCHITECT FOR APPROVAL. 13. ALL FLOOR DRAINS AND FLOOR SINKS SHALL BE PROVIDED WITH CODE- APPROVED ACCESSIBLE TRAP PRIMERS. 14. INSULATE INDIRECT DRAIN LINES FROM REFRIGERATORS, FREEZERS, ICE BINS, ETC., TO PREVENT CONDENSATION. 15. INSULATE ALL CONDENSATE AND WASTE PIPING RECEIVING CONDENSATE DRAIN INCLUDING THE DRAIN BODY. 16. PROVIDE AND INSTALL CHROME PLATED ANGLE STOPS AT ALL FIXTURES. 17. ALL WATER SHUT -OFF VALVES SHALL BE BALL TYPE VALVES. 18. ALL PIPE PENETRATIONS THROUGH STRUCTURAL MEMBERS AND WALLS SHALL BE APPROVED BY THE STRUCTURAL ENGINEER. 19. FOR ALL CORING OF FLOOR, CONTRACTOR SHALL X-RAY THE FLOOR SLAB PRIOR TO CORING. PLUMBING NOTES 6 1. ALL WORK SHALL COMPLY WITH THE LOCAL CODES, 2006 UNIFORM PLUMBING CODE, ENERGY CODE AND ALL OTHER GOVERNING CODES AND ORDINANCES. 2. 8x11 PROJECT MANUALS, INCLUDING, EQUIPMENT AND FIXTURES AND BUILDING STANDARDS SHALL BE A PART OF THIS WORK. 3. ALL SYMBOLS SHOWN ON THE SYMBOL LIST ARE NOT NECESSARILY USED IN THIS PROJECT. 4. WHERE THERE IS A DISCREPANCY BETWEEN THE DRAWINGS AND THE PROJECT MANUAL, BUILDING STANDARDS OR SPECIFICATIONS, NOTIFY THE ARCHITECT PRIOR TO PROCEEDING WITH THE WORK. 5. THE WORK OF THIS PROJECT INVOLVES ALTERATION OF THE BASE BUILDING (PFP) SYSTEMS TO ACHIEVE THE ARRANGEMENT INDICATED ON THE DRAWINGS. THE CONTRACTOR SHALL VISIT THE JOB SITE TO DETERMINE THE EXTENT OF WORK REQUIRED BY THE CONSTRUCTION ACTIVITIES. THE ARCHITECTURAL DRAWINGS SHOW THE CHANGES TO BE MADE. THE CONTRACTOR SHALL REVISE, REARRANGE, REROUTE OR REMOVE EXISTING PLUMBING COMPONENTS AS REQUIRED TO ACCOMMODATE THE CHANGES. 6. THESE DRAWINGS INDICATE THE DESIGN INTENT REQUIREMENTS FOR THE (PFP) SYSTEMS, AND EQUIPMENT. DUE TO STRUCTURAL CONDITIONS, ELECTRICAL WIRING OR PIPING INTERFERENCE, OR FOR OTHER REASONS, THE CONTRACTOR MAY DESIRE TO INSTALL THE WORK IN A MANNER DIFFERENT FROM THAT SHOWN TO ACCOMMODATE EXISTING FIELD CONDITIONS. 7. DURING BID, THE CONTRACTOR SHALL EXAMINE THE COMPLETE SET OF DRAWINGS FOR ALL TRADES, AS ISSUED BY THE ARCHITECT AND REVIEW DIMENSIONS SPACE REQUIREMENTS AND POINT OF CONNECTIONS TO ALL EQUIPMENT. MAKE ANY MINOR ADJUSTMENTS NECESSARY TO AVOID CONFLICTS WITH THE BUILDING STRUCTURE AND THE WORK OF OTHER TRADES. 8. UNLESS INSTRUCTED OTHERWISE, THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, LICENSES, AND FEES REQUIRED FOR INSTALLATION OF THE (PFP) WORK, INCLUDING THE LOCAL DEPARTMENT OF BUILDING AND SAFETY, DEPARTMENT OF WATER AND POWER, CALIFORNIA GAS CO. AND ALL OTHER AGENCIES HAVING JURISDICTION OVER SERVICES TO THIS BUILDING. FURNISH FINAL CERTIFICATE OF INSPECTION OR WRITTEN EVIDENCE OF ACCEPTANCE BY INSPECTION AUTHORITIES FOR ALL WORK INSTALLED. 9. SEE FOOD CONSULTANT DRAWINGS FOR EXTENT OF TENANT IMPROVEMENT WORK, AND EXACT LOCATION OF FIXTURES, EQUIPMENT, DEVICES , ETC. 10. CONTRACTOR SHALL COORDINATE WITH ALL TRADES TO ENSURE AN UNDERSTANDING OF THE COMPLETE SCOPE OF PROJECT PRIOR TO START OF WORK. 11. THE ALTERATION OF THE BASE BUILDING (PFP) SYSTEMS IS A COMPLEX WORK IN NATURE WHICH WILL REQUIRE ACCURATE PLANNING, CAREFUL PREPARATION AND EXECUTION, ATTENTION TO DETAIL AND CLOSE SUPERVISION BY THE CONTRACTOR. THE CONTRACTOR WILL BE REQUIRED TO DO HIS WORK IN FULL COOPERATION WITH THE OTHER CONSTRUCTION TRADES. 12. BEFORE SUBMITTING PROPOSALS FOR THIS WORK, EACH BIDDER SHALL BECOME FAMILIAR WITH DRAWINGS AND SHALL HAVE EXAMINED THE PREMISES AND BE AWARE OF ALL EXISTING CONDITIONS UNDER WHICH HE SHALL BE OBLIGATED TO OPERATE IN PERFORMING HIS CONTRACT. THE CONTRACTOR SHALL NOT BE ENTITLED TO ANY EXTRA COMPENSATION FOR FAILURE TO ALLOW FOR ALL EXISTING CONDITIONS. SUBMITTING OF A BID OR PROPOSAL WILL BE CONSIDERED EVIDENCE OF THE FACT THAT CONTRACTOR IS FULLY AWARE OF THESE CONDITIONS AND IS ABLE TO COMPLETE ALL WORK REQUIRED BY THE DRAWINGS. 13. CONTRACTOR SHALL PROVIDE COMPLETE AS -BUILT DRAWINGS PRIOR TO COMPLETION OF PROJECT FOR REVIEW BY THE ARCHITECT /ENGINEER. 14. IF ANY EQUIPMENT SUBMITTED BY THE CONTRACTOR IS DIFFERENT FROM THAT SPECIFIED, OR REQUIRES CHANGES IN MATERIAL OR LABOR FROM THAT REQUIRED IN THE CONTRACT DOCUMENTS AFFECTING HIS AND /OR OTHER TRADES, SUCH CHANGES SHALL BE SUBMITTED AS SHOP DRAWINGS. SUBMITTAL SHALL INDICATE CREDIT DUE TO OWNER, IF ANY, BECAUSE OF THE CHANGES. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR PAYMENT OF ALL CHARGES RESULTING FROM ADDITIONS OR CHANGES IN THE WORK OF OTHER TRADES NECESSARY TO ACCOMMODATE THE REQUESTED MODIFICATION. ALL CHANGES SHALL BE SHOWN ON RECORD AS -BUILT DRAWINGS. 15. SUBMIT SHOP DRAWINGS AND PRODUCT DATA ACCORDING TO SPECIFICATIONS. GENERAL NOTES SHEET INDEX SYMBOLS SHEET NO. P0.1 P0.2 P0.3 P1.1 T &P REUEF VALVE PROVIDE SEISMIC STRAPS FLOOR SINK SYMBOLS GW C CD CWV DS 1.1 S AP ACCESS PANEL ASR AUTO. FIRE SPRINKLER RISER BFP BACK FLOW PREVENTER BC BALANCING COCK CB CATCH BASIN COYB CLEANOUT IN YARD BOX CO CLEANOUT HDR HEADER I.D. INDIRECT DRAIN I.E. INVERT ELEVATION MH MANHOLE NOTE: SHEET TITLE SYMBOLS, ABBREVIATIONS AND NOTES PLUMBING SCHEDULE PLUMBING RISER DIAGRAM PLUMBING ROOF PLAN ABBREV. W W V CW HW HWR GW G CD SOL CWV DS FS WCO CO FD POC TP 0 - DRIP PAN Iil 1. PROVIDE REMOTE TYPE THERMOMETERS IF MOUNTED HIGHER THAN 6 FT. ABOVE FLOOR. 2. INSTALL THERMOMETERS AND AQUASTATS IN OVERSIZED TEES. 3. - DENOTES ELECTRICAL REQUIREMENTS, COORDINATE WITH DIVISION 16. 4. WHERE A HOT WATER HEATER IS LOCATED AT AN ELEVATION ABOVE THE FIXTURE OUTLETS IN THE HOT WATER SYSTEM, A VACUUM REUEF VALVE SHALL BE INSTALLED ON THE HEATER. R S A I R IR GS OR 6. WATER HEATER DRIP PAN SHALL BE MINIMUM 4" DEEP. PIPING SCHEMATIC FOR SINGLE WATER HEATER DESCRIPTION SEWER WASTE ABOVE SEWER WASTE BELOW VENT LINE COLD WATER HOT WATER HOT WATER RETURN GREASE WASTE GAS CONDENSATE DRAIN SOIL ,WASTE ABOVE FLOOR OR GRADE COMBINATION WASTE & VENT DOWNSPOUT NEW TO EXISTING CONNECTION FLOOR SINK WALL CLEAN OUT CLEAN OUT TO GRADE FLOOR DRAIN POINT OF CONNECTION TRAP PRIMER RIC ROUGH -IN & CONNECT RD ROOF DRAIN SOC SHUT OFF COCK SOV SHUT OFF VALVE NA NOT APPLICABLE N.I.C. NOT IN CONTRACT ORD OVERFLOW ROOF DRAIN PRV PRESSURE REDUCING VALVE (N) NEW (E) EXISTING PFP PLUMBING & FIRE PROTECTION UN G D AILS. FILE OPY Permit No., rOe• w0/5 Mar review approval is subject to errors and mss. A pproval of � 4 s �e th v of any or �a Receipt o' approved = d Copy = ' .. .; ,' is a °�> ed: REVISIONS No changes shad be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan re fees REVISItIIN NII; 1 -0 City of Tukwila C!IS!ON SCALE NONE NONE NONE 1 /4 " =1' -0" SEPARATE PERMIT REQUIRED FOR Mechanical Electrical O Plumbing ❑ Gas Piping City of Tukwila BUILDING DIVISION PROVIDE SEISMIC STRAPS RECEIVE[ HAY, 152 PERMIT CENTEI- ll�� I EXPIRES 4 -17 -2009 l XIaAN RILL 2600 SOUTHCENTER MALL, SPACE # FC -2 TUKWILA, WASHINGTON ISSUED FOR BIDDING ISSUED FOR PERMIT ISSUED FOR CONSTRUCTION ISSUED FOR: DESIGNED BY: — DRAWN BY: — 3ida 80 -6Z -EO KENN BUTTS A.I.A. JOB NUMBER: 07936 Kenneth L. Butts Architect 124 STAGECOACH ROAD BELL CANYON, CA. 91307 TEL. (818) 999 4272 FAX. (818) 999 4321 SHEET TITLE: PLUMBING FLOOR PLAN Y V KULKARNI, P.E. (MECHANICAL AND ELECTRICAL) 39371 SPANISH BAY PLACE DAVIS, CA 95616 E -MAIL YASHAVANT@COX.NET FOR PROJECT COORDINATION CONTACT PROJECT MANAGER KIM KIMIAGAR 310 576 1553 PHONE 310 576 1569 FAX REVISION LANDLORD PLAN CHECK COMMENTS 3 -17 -08 I ISSUED FOR BIDDING ISSUED FOR PERMIT ISSUED FOR CONSTRUCTION ISSUED FOR: DESIGNED BY: — DRAWN BY: — 3ida 80 -6Z -EO DATE: 03.29.2008 JOB NUMBER: 07936 FILE #: P1.1.DWG SHEET TITLE: PLUMBING FLOOR PLAN SCALE: AS NOTED SHEET NUMBER: P1 .1 1.<<<<<<<< miss! HEALTH DEPARTMENT SUBMITTAL PERLIMINARY SUBMITTAL PLAN DEPARTMENT SUBMITTAL & WESTFIELD FINAL SUBMITTAL 31da I 80- 60 -10I 80- l I. -ZOI 80- 90 -20I ISSUED FOR APPROVAL ISSUED FOR PLAN CHECK ISSUED FOR BIDDING ISSUED FOR PERMIT ISSUED FOR CONSTRUCTION ISSUED FOR: DESIGNED BY: — DRAWN BY: — CHECKED BY: — REVIEWED BY: — DATE: 03.29.2008 JOB NUMBER: 07936 FILE #: P1.1.DWG SHEET TITLE: PLUMBING FLOOR PLAN SCALE: AS NOTED SHEET NUMBER: P1 .1 3. TENANT CONTRACTOR SHALL VERIFY POINTS OF CONNECTION FOR ALL VENT, SEWER, AND WATER PIPING WITH MALL MANAGEMENT BEFORE PROCEEDING WITH WORK. TENANT IS RESPONSIBLE FOR EXTENDING PIPING FROM POINT OF EXISTING CONNECTIONS TO TENANT SPACE AT TENANT EXPENSE. ANDLORD NOTES: 1. TENANT SHALL CONNECT GREASE WASTE PIPE TO LANDLORD PROVIDED COMMON 4 GREASE WASTE PIPE THAT TERMINATES INTO A COMMON GREASE INTERCEPTOR OUTSIDE THE BUILDING IN THE PARKING LOT. 2. ALL TENANTS ON THE GROUND FLOOR REQUIRING BELOW GRADE WORK SHALL COORDINATE WITH LANDLORD PRIOR TO ANY SLAB DEMOLITION. TENANT SHALL COORDINATE WITH LANDLORD TO PROVIDE OPPORTUNITY FOR SPECIAL INSPECTION AND PHOTOGRAPHIC DOCUMENTATION BY LANDLORD OF BELOW GRADE WORK PRIOR TO THE COVERING UP OF SUCH WORK. TENANT SHALL BE RESPONSIBLE FOR RECONSTRUCTION AND PATCHING OF THE SLAB -ON -GRADE SYSTEM, INCLUDING GRAVEL LAYERS, VAPOR = R : D SE R V FiLD 0R1 U FIELD VERIFY THE LOCATION FIELD VERIFY THE L EXISTING 3" VENT UNE FIELD COORDINATE AND FIELD VERIFY THE LOCATION DRAWING NOTES: a SEE ARCHITECTURAL DRAWINGS FOR MOUNTING DETAILS. ® SEE KITCHEN EQUIPMENT SCHEDULE AT SHEET K FOR MORE INFORMATION. PLUMBING FLOOR PLAN (WASTE & VENT) SCALE: 1/4"=V t� �itei refit �"�� igt� �i rife tritr¢�Gir�tririG t ref �r���� Riisj�% l 4t rtrt rtr5' %riri ttri rrrr+frri ctrl rrrt cr r� ti ri r� riri rtfi tr�i ctrl PLUMBING FLOOR PLAN (WATER& GAS) 11N 2" ,qW LINE NA NA FIELD DRAWING NOTES: 0 SEE ARCHITECTURAL DRAWINGS FOR MOUNTING DETAILS. 0 SEE KITCHEN EQUIPMENT SCHEDULE AT SHEET K FOR MORE INFORMATION. SCALE: 1/4"=1'-0" RECEIVED MAY; 152008 PERMIT CENTER 4-17-2009 1 I EXPIRES N • LANDLORD PROVIDED A TENANT FIRE SERVICE MAIN WITH BRANCH PIPING STUBBED INTO EACH TENANT'S SPACE. LANDLORD'S SPRINKLER SYSTEM IS DESIGNED PER ORDINARY HAZARD GROUP 2 AND THE LATEST REQUIREMENTS OF NFPA -13. NO ISOLATION VALVES WILL BE PROVIDED OR PERMITTED. • TENANT SHALL CONNECT A FIRE SPRINKLER SYSTEM TO LANDLORD'S SPRINKLER SYSTEM WITHIN THE DEMISED PREMISES USING APPROVED MECHANICAL FITTINGS. TENANT SHALL PROVIDE AND INSTALL ALL BRANCH PIPING AND SPRINKLERS REQUIRED TO COMPLETE THE SPRINKLER SYSTEM WITHIN THE TENANT SPACE. TENANT'S SPRINKLER SYSTEM DESIGNS SHALL BE BASED UPON THE REQUIREMENTS OF THE STATE OF WASHINGTON, CITY OF TUKWILA FIRE DEPARTMENT. TENANT SHALL ENGAGE THE SERVICES OF A LANDLORD PREFERRED FIR SPRINKLER CONTRACTOR TO DESIGN, PERMIT AND INSTALL TENANT'S FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH THE BASE BUILDING DESIGN SPECIFICATIONS. SPRINKLER LAYOUT AND PIPE SIZING SHALL BE HYDRAULICALLY DESIGNED ACCORDING TO ORDINARY HAZARD GROUP 2 AND THE LATEST REQUIREMENTS OF NFPA -13. • ALL SPRINKLER HEADS IN THE FORWARD SELLING AREA ARE TO BE CONCEALED POP -OFF COVER TYPE. • ALL SUPPORTS SHALL BE FROM STRUCTURAL BEAMS AND JOISTS, NOT FROM FLOOR OR ROOF DECK ABOVE. • TENANT'S CONTRACTOR SHALL INSTALL AN INSPECTORS TEST CONNECTION, PIPED TO A FUNNEL DRAIN, (WITH WET TRAP), MOUNTED 3' -O" A.F.F. INSTALL A 1" CORROSION RESISTANT SHUT -OFF VALVE. • TENANT SHALL INSTALL A VANE TYPE WATERFLOW DETECTOR IN THE MAIN SPRINKLER LINE IMMEDIATELY AFTER CONNECTION TO THE LANDLORD'S MAIN, WHICH IS CONNECTED TO THE LANDLORD'S FIRE ALARM SYSTEM. 1. ALL WORK SHALL COMPLY WITH THE LOCAL CODES, 2006 UNIFORM PLUMBING CODE, ENERGY CODE AND ALL OTHER GOVERNING CODES AND ORDINANCES. 2. 8x11 PROJECT MANUALS, INCLUDING, EQUIPMENT AND FIXTURES AND BUILDING STANDARDS SHALL BE A PART OF THIS WORK. 3. ALL SYMBOLS SHOWN ON THE SYMBOL LIST ARE NOT NECESSARILY USED IN THIS PROJECT. 4. WHERE THERE IS A DISCREPANCY BETWEEN THE DRAWINGS AND THE PROJECT MANUAL, BUILDING STANDARDS OR SPECIFICATIONS, NOTIFY THE ARCHITECT PRIOR TO PROCEEDING WITH THE WORK. 5. THE WORK OF THIS PROJECT INVOLVES ALTERATION OF THE BASE BUILDING (PFP) SYSTEMS TO ACHIEVE THE ARRANGEMENT INDICATED ON THE DRAWINGS. THE CONTRACTOR SHALL VISIT THE JOB SITE TO DETERMINE THE EXTENT OF WORK REQUIRED BY THE CONSTRUCTION ACTIVITIES. THE ARCHITECTURAL DRAWINGS SHOW THE CHANGES TO BE MADE. THE CONTRACTOR SHALL REVISE, REARRANGE, REROUTE OR REMOVE EXISTING PLUMBING COMPONENTS AS REQUIRED TO ACCOMMODATE THE CHANGES. 6. THESE DRAWINGS INDICATE THE DESIGN INTENT REQUIREMENTS FOR THE (PFP) SYSTEMS, AND EQUIPMENT. DUE TO STRUCTURAL CONDITIONS, ELECTRICAL WIRING OR PIPING INTERFERENCE, OR FOR OTHER REASONS, THE CONTRACTOR MAY DESIRE TO INSTALL THE WORK IN A MANNER DIFFERENT FROM THAT SHOWN TO ACCOMMODATE EXISTING FIELD CONDITIONS. 7. DURING BID, THE CONTRACTOR SHALL EXAMINE THE COMPLETE SET OF DRAWINGS FOR ALL TRADES, AS ISSUED BY THE ARCHITECT AND REVIEW DIMENSIONS SPACE REQUIREMENTS AND POINT OF CONNECTIONS TO ALL EQUIPMENT. MAKE ANY MINOR ADJUSTMENTS NECESSARY TO AVOID CONFLICTS WITH THE BUILDING STRUCTURE AND THE WORK OF OTHER TRADES. 8. UNLESS INSTRUCTED OTHERWISE, THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, LICENSES, AND FEES REQUIRED FOR INSTALLATION OF THE (PFP) WORK, INCLUDING THE LOCAL DEPARTMENT OF BUILDING AND SAFETY, DEPARTMENT OF WATER AND POWER, CALIFORNIA GAS CO. AND ALL OTHER AGENCIES HAVING JURISDICTION OVER SERVICES TO THIS BUILDING. FURNISH FINAL CERTIFICATE OF INSPECTION OR WRITTEN EVIDENCE OF ACCEPTANCE BY INSPECTION AUTHORITIES FOR ALL WORK INSTALLED. 9. SEE FOOD CONSULTANT DRAWINGS FOR EXTENT OF TENANT IMPROVEMENT WORK, AND EXACT LOCATION OF 1Electrica► FIXTURES, EQUIPMENT, DEVICES , ETC. 10. CONTRACTOR SHALL COORDINATE WITH ALL TRADES TO ENSURE AN UNDERSTANDING OF THE COMPLETE SCOPE OF PROJECT PRIOR TO START OF WORK. 11. THE ALTERATION OF THE BASE BUILDING (PFP) SYSTEMS IS A COMPLEX WORK IN NATURE WHICH WILL REQUIRE ACCURATE PLANNING, CAREFUL PREPARATION AND EXECUTION, ATTENTION TO DETAIL AND CLOSE SUPERVISION BY THE CONTRACTOR. THE CONTRACTOR WILL BE REQUIRED TO DO HIS WORK IN FULL COOPERATION WITH THE OTHER CONSTRUCTION TRADES. 12. BEFORE SUBMITTING PROPOSALS FOR THIS WORK, EACH BIDDER SHALL BECOME FAMILIAR WITH DRAWINGS AND SHALL HAVE EXAMINED THE PREMISES AND BE AWARE OF ALL EXISTING CONDITIONS UNDER WHICH HE SHALL BE OBLIGATED TO OPERATE IN PERFORMING HIS CONTRACT. THE CONTRACTOR SHALL NOT BE ENTITLED TO ANY EXTRA COMPENSATION FOR FAILURE TO ALLOW FOR ALL EXISTING CONDITIONS. SUBMITTING OF A BID OR PROPOSAL WILL BE CONSIDERED EVIDENCE OF THE FACT THAT CONTRACTOR IS FULLY AWARE OF THESE CONDITIONS AND IS ABLE TO COMPLETE ALL WORK REQUIRED BY THE DRAWINGS. 13. CONTRACTOR SHALL PROVIDE COMPLETE AS -BUILT DRAWINGS PRIOR TO COMPLETION OF PROJECT FOR REVIEW BY THE ARCHITECT /ENGINEER. 14. IF ANY EQUIPMENT SUBMITTED BY THE CONTRACTOR IS DIFFERENT FROM THAT SPECIFIED, OR REQUIRES CHANGES IN MATERIAL OR LABOR FROM THAT REQUIRED IN THE CONTRACT DOCUMENTS AFFECTING HIS AND /OR OTHER TRADES, SUCH CHANGES SHALL BE SUBMITTED AS SHOP DRAWINGS. SUBMITTAL SHALL INDICATE CREDIT DUE TO OWNER, IF ANY, BECAUSE OF THE CHANGES. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR PAYMENT OF ALL CHARGES RESULTING FROM ADDITIONS OR CHANGES IN THE WORK OF OTHER TRADES NECESSARY TO ACCOMMODATE THE REQUESTED MODIFICATION. ALL CHANGES SHALL BE SHOWN ON RECORD AS -BUILT DRAWINGS. 15. SUBMIT SHOP DRAWINGS AND PRODUCT DATA ACCORDING TO SPECIFICATIONS. SHEET ISSUED FOR PERMIT ISSUED FOR CONSTRUCTION NO. SHEET TITLE SCALE DRAWN BY: - P0.1 SYMBOLS, ABBREVIATIONS AND NOTES NONE P0.2 PLUMBING SCHEDULE NONE PO.3 PLUMBING RISER DIAGRAM NONE P1.1 PLUMBING ROOF PLAN 1 /4 " 1'--0" SHEET INDEX 'I JOB NUMBER: 07936 FILE #: PO.1.DWG SYMBOLS ABBREV. DESCRIPTION r«««« Kenneth L. Architect w W V CW HW HWR GW G CD SOL CWV DS FS WCO CO FD POC TP SEWER WASTE ABOVE SEWER WASTE BELOW VENT LINE COLD WATER HOT WATER HOT WATER RETURN GREASE WASTE GAS CONDENSATE DRAIN SOIL ,WASTE ABOVE FLOOR OR GRADE COMBINATION WASTE & VENT DOWNSPOUT NEW TO EXISTING CONNECTION FLOOR SINK WALL CLEAN OUT CLEAN OUT TO GRADE FLOOR DRAIN POINT OF CONNECTION TRAP PRIMER TEL. (818) 999 4272 FAX. (818) 999 4321 ISSUE Y V KULKARNI, P.E. • 39371 SPANISH BAY PLACE DAVIS, CA 95616 E -MAIL YASHAVANT©COX.NET • • • GW CONTACT PROJECT MANAGER G 310 576 1553 PHONE CD BO- 11 -Z01 1 03 -06 -08 CWV • DS 8 Ik LANDLORD FIRE PROTECTION NOTES 1. ALL WORK SHALL COMPLY WITH THE 2006 UNIFORM PLUMBING CODE, AND LOCAL CODES. 2. ALL CLEAN OUTS SHALL BE ACCESSIBLE AND INSTALLED PER 2006 UNIFORM PLUMBING CODE AND UNIFORM PLUMBING CODE SECTION 707 & 719. 3. ALL WATER FAUCETS SHALL BE PROVIDED WITH CODE - APPROVED FLOW RESTRICTORS. 4. SLOPE OF SANITARY SEWER PIPES SHALL NOT BE LESS THAN 2% UNLESS OTHERWISE INDICATED AND O APPROVED BY THE AUTHORITY HAVING JURISDICTION. 5. ALL DOMESTIC HOT WATER PIPING SHALL BE INSULATED AS REQUIRED BY THE ENERGY CODE. 6. ALL PIPING TO BE SEISMICALLY BRACED TO PREVENT SWAYING PER LOCAL AND STATE BUILDING CODE. 7. PROVIDE SNAP -ON TYPE INSULATION ON TRAPS AND HOT WATER PIPING FOR SINKS AND OTHER A.D.A. ACCESSIBLE FIXTURES. 8. DURING CONSTRUCTION, PROVIDE MECHANICAL PLUGS IN OPEN DRAINS TO PREVENT DAMAGE TO LOWER FLOORS. ALL WATER PIPING LOCATED ABOVE CEILING, REQUIRING TEMPORARY OR PERMANENT CAPPED CONNECTIONS, SHALL BE PROVIDED WITH LINE -SIZE SHUTOFF VALVES. 9. ROUGH -INS, CONNECTIONS AND TERMINATION OF PLUMBING WORK SHALL BE SEQUENCED IN COORDINATION WITH THE PROJECT SCHEDULE THE ARCHITECT, AND THE OWNERS OTHER CONTRACTORS AND VENDORS. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS OF FIXTURES AND APPLIANCES. 10. A MINIMUM 1 /2" CLEARANCE SHALL BE PROVIDED AROUND PIPES AT ALL PENETRATIONS THROUGH WALLS AND ROOF. THE GAP SHALL BE PACKED TIGHTLY WITH LOOSE, LIGHTWEIGHT INSULATION THROUGH NON RATED WALLS, AND APPROVED U.L. LISTED FIRE SAFING MATERIAL RATED WALLS TO MATCH WALL RATING. 11. PROVIDE AND INSTALL ACCESSIBLE WATER HAMMER ARRESTERS OF REQUIRED SIZE AND LOCATION. MANUFACTURER AND MODEL NUMBERS SHALL BE PER SPECIFICATIONS. 12. PROVIDE ACCESS PANELS IN WALLS FOR SHUTOFF VALVES, TRAP PRIMERS AND WATER HAMMER ARRESTERS. CONTRACTOR IS ADVISED THAT ITEMS REQUIRING ACCESS SHALL NOT BE LOCATED ABOVE THE AREAS OF GYPSUM BOARD CEILING WITHOUT CONSENT OF ARCHITECT. SUBMIT PROPOSED ACCESS PANEL LOCATIONS TO ARCHITECT FOR APPROVAL. 13. ALL FLOOR DRAINS AND FLOOR SINKS SHALL BE PROVIDED WITH CODE- APPROVED ACCESSIBLE TRAP PRIMERS. 14. INSULATE INDIRECT DRAIN LINES FROM REFRIGERATORS, FREEZERS, ICE BINS, ETC., TO PREVENT CONDENSATION. 15. INSULATE ALL CONDENSATE AND WASTE PIPING RECEIVING CONDENSATE DRAIN INCLUDING THE DRAIN BODY. 16. PROVIDE AND INSTALL CHROME PLATED ANGLE STOPS AT ALL FIXTURES. 17. ALL WATER SHUT -OFF VALVES SHALL BE BALL TYPE VALVES. 18. ALL PIPE PENETRATIONS THROUGH STRUCTURAL MEMBERS AND WALLS SHALL BE APPROVED BY THE STRUCTURAL ENGINEER. 19. FOR ALL CORING OF FLOOR, CONTRACTOR SHALL X -RAY THE FLOOR SLAB PRIOR TO CORING. a a a 0 �TP� AP ACCESS PANEL RIC ROUGH -IN & CONNECT ASR AUTO. FIRE SPRINKLER RISER RD ROOF DRAIN BFP BACKFLOW PREVENTER SOC SHUT OFF COCK BC BALANCING COCK SOV SHUT OFF VALVE CB CATCH BASIN NA NOT APPLICABLE COYB CLEANOUT IN YARD BOX N.I.C. NOT IN CONTRACT CO CLEANOUT ORD OVERFLOW ROOF DRAIN HDR HEADER PRV PRESSURE REDUCING VALVE I.D. INDIRECT DRAIN (N) NEW I.E. INVERT ELEVATION E ) EXISTING MH MANHOLE PFP PLUMBING & FIRE PROTECTION SYMBOLS �� ��� REVISIONS �� ®�� bemadetothescopA Permit �p changes shall of work without priorapproV& �: Tukwila Building Division - � �' , Pier reviewa�is�tD 9 ` • Ap�rovalof��doesrtl�� N ®TE: Rev. sionswilirequirPanpw�i�r +�llhm "�+�I � ` -���" c ' "2- „ ` ' snd may include adc�il'o ^al Tarr r e ,!����, €ee� =_ the violation of any d code or �. t _ __ _. _ - - _ _ . - . = - zss� 4 v of approved � =�- • Copy and .r. ,;�, • -, is acknowledged: ����1 �� ± � 9 � -', �`�' ��_� .__= ay �� a_ `��:.! � 2006 8 1 Date: - �xl l: 12 'd 1'4 titj/ofTUlcwila , BUILDING DIVISION T ��irA�ATE P�i�f�i i \ e, �E UtBEO F4Ft� �Mechanica% lil -� ] I �] Plumtair►g p Gas Piping Icwita - - - - `� E� � � i CO DC APPR BAR - () ? fl t, °1 l 4 ■ C�tyofTu - g�11,p6NG DIV1510N T T T&P VALVE °I REUEF PROVIDE SEISMIC STRAPS ° (EH) / / ° p o ° PROVIDE SEISMIC STRAPS DRAIN W "mi l- VALVE - - 3 z I s - = 1 - - • - DRIP PAN FLOOR SINK J ' NOTE: 1. PROVIDE REMOTE TYPE THERMOMETERS IF MOUNTED HIGHER THAN 6 KECENED ABOVE FLOOR MAR 13 2. INSTALL THERMOMETERS AND AQUASTATS IN OVERSIZED TEES. PERMIT CENTER 3. ©E DENOTES ELECTRICAL REQUIREMENTS, COORDINATE WITH DIVISION 16. 4. WHERE A HOT WATER HEATER IS LOCATED AT AN ELEVATION ABOVE THE FIXTURE OUTLETS IN THE HOT WATER SYSTEM, A VACUUM REUEF VALVE SHALL BE INSTALLED ON THE HEATER. 5. REFER TO ARCHITECTURAL DRAWINGS FOR MOUNTING DETAILS. 0 07 PLUMBING NOTES 5 GENERAL NOTES 4 PIPING SCHEMATIC FOR SINGLE WATER HEATER 3 REVISION ISSUED FOR PLAN CHECK ISSUED FOR BIDDING ISSUED FOR PERMIT ISSUED FOR CONSTRUCTION ISSUED FOR DESIGNED BY: - DRAWN BY: - 31b0 REVIEWED BY: - DATE: 03.05.200 8 JOB NUMBER: 07936 FILE #: PO.1.DWG SHEET TITLE: PLUMBING SYMBOLS NOTES & ABBRV SCALE AS NOTED KENN BUTTS M.A. Butts / \ r«««« Kenneth L. Architect 124 STAGECOACH ROAD BELL CANYON, CA. 91307 TEL. (818) 999 4272 FAX. (818) 999 4321 ISSUE Y V KULKARNI, P.E. (MECHANICAL AND ELECTRICAL) 39371 SPANISH BAY PLACE DAVIS, CA 95616 E -MAIL YASHAVANT©COX.NET FOR PROJECT COORDINATION CONTACT PROJECT MANAGER KIM KIMIAGAR 310 576 1553 PHONE 310 576 1569 FAX BO- 11 -Z01 REVISION ISSUED FOR PLAN CHECK ISSUED FOR BIDDING ISSUED FOR PERMIT ISSUED FOR CONSTRUCTION ISSUED FOR DESIGNED BY: - DRAWN BY: - 31b0 REVIEWED BY: - DATE: 03.05.200 8 JOB NUMBER: 07936 FILE #: PO.1.DWG SHEET TITLE: PLUMBING SYMBOLS NOTES & ABBRV SCALE AS NOTED SHEET NUMBER: P0.1 r«««« ISSUE HEALTH DEPARTMENT SUBMITTAL PERLIMINARY SUBMITTAL PLAN DEPARTMENT SUBMITTAL & WESTFIELD FINAL SUBMITTAL 3140 I 80 -60 -101 BO- 11 -Z01 1 03 -06 -08 ISSUED FOR APPROVAL ISSUED FOR PLAN CHECK ISSUED FOR BIDDING ISSUED FOR PERMIT ISSUED FOR CONSTRUCTION ISSUED FOR DESIGNED BY: - DRAWN BY: - CHECKED BY: - REVIEWED BY: - DATE: 03.05.200 8 JOB NUMBER: 07936 FILE #: PO.1.DWG SHEET TITLE: PLUMBING SYMBOLS NOTES & ABBRV SCALE AS NOTED SHEET NUMBER: P0.1 REVISION I ISSUED FOR BIDDING _LN\ IR) BUILDING FIXTURE UNITS 31.5 — 18 GPM . JUTHCENTER MALL, SPACE # FC -2 TUKWILA, WASHINGTON CW LINE = 2" DESIGNED BY: - PLUMBING FIXTURE SCHEDULE CHECKED BY: - 3140 BUILDING EXTERNAL PRESSURE LOSS EQUIPMENT FILE #: P0.2.DWG PLUMBING PRV SET AT 80 PSI LOW PRESSURE = 70 PSI. ITEM DESCRIPTION QTY MANUFACTURE /MODEL NO. HW CW FUEL GAS WASTE TEL. (818) 999 4272 SIZED FOR 70 PSI (LOW) — WATER METER (EXIST. 1-1/2") 3 PSI CONN MBTU DIR. I.W. REMARK 1 2 HOT WATER HEATER THREE COMPARTMENT SINK 1 1 BY PLUMBER CUSTOM ST /ST 1 /2" 1/2" 1 /2" 1/2" 100 310 576 1569 FAX 2" I.W. TO FLOOR SINK — BACK FLOW PREVENTER (EXIST.) — PSI — PRESSURE REDUCING VALVE (EXIST.) — PSI 6 MOP SINK W /FAUCET 1 ADVANCE #9 —OP -28 1/2" 1/2" 2" TRAP BELOW FLOOR PRESSURE AVAILABLE AT BUILDING ENTRANCE 67 PSI 13 HANDSINK 1 ADVANCE #7 —PS -20 1/2" 1/2" 1-1/2" DIRECT WASTE 17 HOT FOOD WELL 1 WELLS #H T— 300AF 1 /2" 1" I.W. TO FLOOR SINK BUILDING INTERNAL PRESSURE LOSS 21 29 COLD PAN PIZZA OVEN 1 1 WELLS #ICP -100 WOODSTONE #4343 3/4" 80 1" I.W. TO FLOOR SINK BUILDING STATIC PRESSURE HEIGHT 24 HEIGHT X 0.434 = 10.42 PSI 37 FRYER 2 FRYMASTER #FP247 1/2" 244 PRESSURE REQUIRED AT FIXTURE: FLUSH VALVE: — PSI 38 GRIDDLE RANGE 1 JADE #JGM -2224 3/4" 48 39 CHARBROILER RANGE 1 JADE #KC -36 3/4" 95 42 WALK —IN COOLER 1 DURACOLD 1" I.W. TO FLOOR SINK FLUSH TANK: 20 PSI 46 FOUR O.B. RANGE W /OVEN 1 IMPERIAL #IHR -4 1-1/4" 160 BUILDING TOTAL LOSS: 30.42 PSI 49 PREP TABLE W /SINK 1 CUSTOM ST /ST 1/2" 1/2" 1-1/2" I.W. TO FLOOR SINK 56 HANDSINK 1 ADVANCE #7 —PS -20 1/2" 1/2" 1-1/2" DIRECT WASTE AVAILABLE PRESSURE FOR FRICTION LOSS 61 ICE MACHINE 1 HOSHIZAKI # KM -501 MAH 1/2" 1" I.W. TO FLOOR SINK TOTAL LENGTH 350 FT X F 1.2 = TOTAL EQUIVALENT LENGTH (T.E.L.) 420 FT 62 ICE MACHINE BIN 1 HOSHIZAKI #B -500SF 1" I.W. TO FLOOR SINK 68 SODA /ICE DISPENSER 1 BY SODA VENDOR 1 /2" 1" I.W. TO FLOOR SINK (67- 30.42) PSI X 100 FT -.- 420 T.E.L. = 8.7 PSI PER 100 FT 69 TEA MAKERS 2 BUNN #TU3 1/2" PIPES SIZED FOR 2 PSI /100LF (AS REQUIRED BY MALL FACILITIES) P147 Tp_1 TRAP PRIMER PRIME PERFECT 1/2" WATER CALCULATIONS 6 INSTALL IN WALL AS SHOWN IN RISER DIAGRAM WITH DISTRIBUTION UNITS AS INDICATED PER MFGRS. INSTRUCTIONS. FIXTURE WASTE COLD WATER HOT WATER FS -1 FLOOR SINK #49302 WITH JOSAM # TRAP PRIMER VALVE 2" QUANTITY FIXTURE UNITS TOTAL FIXTURE UNITS TOTAL FIXTURE UNITS TOTAL MOP OR SERVICE SINK 1 3 3 3 3 3 3 FLOOR SINK 6 2 12 0 0 0 0 =D -1 FLOOR DRAIN JOSAM #30000 —A W/ STRAINER WITH P —TRAP CONN. FLOOR DRAIN 0 2 0 0 0 0 0 _ NOTES: '.W Ns,���_��� ON L he - 3 COMP. SK (2 FAUCET SETS) 1 3 3 5 5 5 5 PREP SINK 1 2 2 2.5 2.5 2.5 2.5 1. ALL PLUBMING WASTE CONNECTIONS SHALL COMPLY WIYH LOCAL BLDG. DEPT. 2. TRENCH DRAIN INSTALLATION SHALL COMPLY WITH UPC -704.3 3. SEE KITCHEN EQUIPMENT SCHEDULE AT SHEET K FOR MORE INFORMATION. COFFEE MAKER 1 0 0 2 2 0 0 EXPIRES 4 -17 -20041 f. ,.__ ,---- < HAND SINK 2 2 4 2 4 2 4 SODA /ICE DISPENSER 1 0 0 2 2 0 0 li g 0 ICE MACHINE 1 0 0 2 2 0 0 TRAP PRIMER 7 0 0 1 7 0 0 LANDLORD NOTES: 1. PVC PIPING NOT APPROVED FOR PROJECT. TEA MAKERS 2 0 0 2 4 0 0 T O T A L 24 31.5 14.5 ?0 S .....' SEWER LINE — 4" (24) CURVE (FT TYPE) — WATER LINE — 31.5FU (2 "CW) & 1-1/4" HWS(14.5 FU) GPM GPM 18 12 WASTE & WATER FIXTURE UNITS 7 PLUMBING FIXTURE SCHEDULE 1 SERVICE PIPE FITTINGS LOCATION WASTE & VENT CAST IRON NO HUB CAST IRON NO HUB ABOVE GRADE BELOW GRADE PIPE SIZE 1/2" 3/4" 1" 1 1 /4" 1 1 /2" 2" 2 1 /2" PIPE SIZE 1/2" 3/4" 1" 1 1 /4" 1 1 /2" 2" 2 1 /2" STORM DRAIN CAST IRON NO HUB CAST IRON NO HUB ABOVE GRADE BELOW GRADE GPM 2 5 10 17 27 56 84 GPM 2 5 7 15 18 30 40 HOT AND COLD WATER COPPER TYPE "L" HARD DRAWN WROUGHT COPPER ABOVE GRADE COLD WATER COPPER TYPE "L" HARD DRAWN WROUGHT COPPER BELOW GRADE FU 2 6 13 25 47 158 294 FU 1 6 8 21 26 54 83 INDIRECT WASTE CONDENSATE DRAIN GAS COPPER TYPE "M" HARD DRAWN WROUGHT COPPER ABOVE GRADE BLACK STEEL SCHEDULE 40 BLACK STEEL MALLEABLE IRON ABOVE GRADE P206 VELOCITY: 6 FT /SEC MAX. WATER VELOCITY VELOCITY: 4 FT /SEC MAX. WATER VELOCPY CODE tri k COMPLIANCE APP OVE AMR 2 0 2 NOTE: ABS OR PVC DWV MAY BE USED FOR WASTE AND VENT PIPING IF APPROVED BY LOCAL BLDG. DEPT & MALL MGT. PIPE MATERIAL SCHEDULE 8 CW PIPING 4 HW PIPING � Tpttwristr Q 4 2 MARK TANK SIZE STORAGE (CAL) RECOV (GPH) �o° RISE TEMP KW VOLT PHASE LOCATION MANUFACTURER AND MODEL NO. REMARKS rE MARK EQUIPMENT Q � MOTOR DATA CAPACITY HEAD (FF LOCATION C MANUFACTURE & MODEL NO. REMARKS DIAM IN � � HGT. (IN) IN (F) OUT (F) HP AMPS VOLT PHASE 20-1/2" /2 55" 50 164 60 140 36 480 3 SEE PLAN A.O. SMITH DSE -50 PROVIDE D EXPANSION TANK 1 2 1 - -- - -- --- - -- 17.5 GAL - -- SEE PLAN AMTROL ST -12 —C ASME RATED, IAPMO APPROVED AIM Mr EXPANSION TANK ED PROVIDE WITH PRESSURE TEMPERATURE RELIEF VALVE C P © PROVIDE SEISMIC BRACING AS REQUIRED BY LOCAL CODE MAR 13 2008 PERMIT CENTh. !. EQUIPMENT SCHEDULE 5 ELECTRIC WATER HEATER SCHEDULE 3 REVISION I ISSUED FOR BIDDING _LN\ IR) ISSUED FOR CONSTRUCTION JUTHCENTER MALL, SPACE # FC -2 TUKWILA, WASHINGTON ISSUED FOR DESIGNED BY: - DRAWN BY: - CHECKED BY: - 3140 DATE: 03.06.2008 JOB NUMBER: 07936 FILE #: P0.2.DWG SHEET TITLE: PLUMBING SCHEDULES SCALE: AS NOTED SHEET NUMBER: P0.2 KENN BUTTS A.I.A. Butts / 1<<<<<<<<< Kenneth L. Architect 124 STAGECOACH ROAD BELL CANYON, CA. 91307 TEL. (818) 999 4272 FAX. (818) 999 4321 ISSUE HEALTH DEPARTMENT SUBMITTAL Y V KULKARNI, P.E. (MECHANICAL AND ELECTRICAL) 39371 SPANISH BAY PLACE DAVIS, CA 95616 E -MAIL YASHAVANT©COX.NET FOR PROJECT COORDINATION CONTACT PROJECT MANAGER KIM KIMIAGAR 310 576 1553 PHONE 310 576 1569 FAX 80 -90 -2'01 REVISION I ISSUED FOR BIDDING ISSUED FOR PERMIT ISSUED FOR CONSTRUCTION ISSUED FOR DESIGNED BY: - DRAWN BY: - CHECKED BY: - 3140 DATE: 03.06.2008 JOB NUMBER: 07936 FILE #: P0.2.DWG SHEET TITLE: PLUMBING SCHEDULES SCALE: AS NOTED SHEET NUMBER: P0.2 1<<<<<<<<< ISSUE HEALTH DEPARTMENT SUBMITTAL PERLIMINARY SUBMITTAL PLAN DEPARTMENT SUBMITTAL & WESTFIELD FINAL SUBMITTAL 31vO I SO-60- Got 80- I.1 -Z0I 80 -90 -2'01 ISSUED FOR APPROVAL ISSUED FOR PLAN CHECK ISSUED FOR BIDDING ISSUED FOR PERMIT ISSUED FOR CONSTRUCTION ISSUED FOR DESIGNED BY: - DRAWN BY: - CHECKED BY: - REVIEWED BY: - DATE: 03.06.2008 JOB NUMBER: 07936 FILE #: P0.2.DWG SHEET TITLE: PLUMBING SCHEDULES SCALE: AS NOTED SHEET NUMBER: P0.2 / REVISION I ISSUED FOR PLAN CHECK uNNifi I ISSUED FOR PERMIT DUTHCENTER MALL, SPACE # FC -2 TUKWILA, WASHINGTON ISSUED FOR: DESIGNED BY: - DRAWN BY: - 31da REVIEWED BY: - DATE: 03.06.2008 JOB NUMBER: 07936 FILE #: PO.3.DWG SHEET TITLE: PLUMBING RISER DIAGRAM SCALE: AS NOTED SHEET NUMBER: P0.3 KENN BU Q.I.A. Butts ROAD CA. 999 4272 999 4321 S 91307 / Kenneth L. Architect 124 STAGECOACH BELL CANYON, TEL. (818) FAX. (81 8) Y V KULKARNI, P.E. (MECHANICAL AND ELECTRICAL) 39371 SPANISH BAY PLACE DAVIS, CA 95616 E -MAIL YASHAVANT@COX.NET FOR PROJECT COORDINATION CONTACT PROJECT MANAGER KIM KIMIAGAR 310 576 1553 PHONE 310 576 1569 FAX REVISION I ISSUED FOR PLAN CHECK ISSUED FOR BIDDING ISSUED FOR PERMIT ISSUED FOR CONSTRUCTION ISSUED FOR: DESIGNED BY: - DRAWN BY: - 31da REVIEWED BY: - DATE: 03.06.2008 JOB NUMBER: 07936 FILE #: PO.3.DWG SHEET TITLE: PLUMBING RISER DIAGRAM SCALE: AS NOTED SHEET NUMBER: P0.3 i<«««« ISSUE HEALTH DEPARTMENT SUBMITTAL PERLIMINARY SUBMITTAL PLAN DEPARTMENT SUBMITTAL & WESTFIELD FINAL SUBMITTAL 31W I B0 -60- .01 B0- l4 -ZOI BO -90 -201 I SSUED FOR APPROVAL ISSUED FOR PLAN CHECK ISSUED FOR BIDDING ISSUED FOR PERMIT ISSUED FOR CONSTRUCTION ISSUED FOR: DESIGNED BY: - DRAWN BY: - CHECKED BY: - REVIEWED BY: - DATE: 03.06.2008 JOB NUMBER: 07936 FILE #: PO.3.DWG SHEET TITLE: PLUMBING RISER DIAGRAM SCALE: AS NOTED SHEET NUMBER: P0.3 WATER RISER DIAGRAM WASTE RISER DIAGRAM LANDLORD NOTES: TO EXISTING MAIN CW 5- 4' GW CONNECT TO EXISTING 4 MAIN GREASE WASTE UNE CONTRACTOR TO FIELD VERIFY LOCATION 1 GAS RISER DIAGRAM AND CALCULATIONS SHALL INCLUDE PIPING /LOADS TO ROOFTOP EQUIPMENT. 2. ALL FOOD SERVICE AND EXCESSIVE WATER USE TENANTS SHALL BE REQUIRED TO INSTALL A COLD WATER SUBMETER ASSEMBLY (REGISTERING IN GALLONS) WITH PRESSURE REGULATOR, GROUND JUMPER WIRE AND ALL FURTHER INSTALLATIONS AND CONNECTIONS, IN ACCORDANCE WITH ALL GIVEN REQUIREMENTS AT THE REAR PORTION OF THE TENANT SPACE IN A READILY ACCESSIBLE LOCATION, AT A MAXIMUM (48 ") ABOVE THE FINISHED FLOOR. 3. ALL GAS EQUIPMENT SHALL BE ON QUICK DISCONNECTS PER HEALTH DEPARTMENT. 4 `- 3"V CONNECT TO EXISTING 3" MAIN VENT CONTRACTOR TO FIELD VERIFY LOCATION EXISTING 2" SUB-METER FEILD VERIFY THE LOCATION AND SIZE NOTE: RPBP,PRV & MAIN WATER METER SHOWN ON SHELL PLUMBING. 2 KS -1 2" SHUT OFF VALVE T 1 COUNTER 3" V 1 -1/2" V 1-1/2 CW(46 FU) HS -1 J 2ND FLOOR GAS RISER DIAGRAM KS -1 _z 3/4" CW(6) 3/4 CW(3.5) T ES -1 PS -1 2'V 1 -1/2 " FS - T J 1"HW (7.5) HW(2.5) 3/4" CW(3) PS -1 FS -1 1 --1/2 V SPECIFIC NOTES �j THE ACTUATON OF ANY HOOD FIRE SUPPRESSION SYSTEM SHALL CLOSE THE MASTER GAS CONTROL VALVE. CONTRACTOR TO COORDINATE WITH LOCAL GAS COMPANY FOR NEW METER LOCATION. 1/2" HW(2) 3/4" CW(4) HS -1 WALK -IN COOLER 1- 1/47160) 2 \- -- 3/4" HW(3) 1 -1 /4"HW (12.5) 1 -1 /4 "CW(14.5) T MS -1 FS -1 3/4" 80 MBTUH WH -1 L_J 1" ` „ MS - CO LJ 1-1/2" CW(27.5 FU) r 1 -1 /4"HW MANIFOLD (14.5 FU) TP ICE STORATE ICE MACHINE —FS-1 2"V 1-1/2" 1" FS -1 T 1" 95 MBTUH 1 -1/4" CW(12 FU) 3/4' 48 MBTUH 2'V TEA MAKER F L_J 3/4" CW(4) ISLAND COUNTER l FS -1 1" CW(7) AC -1 90 MBTUH F I c-III L_J MASTER GAS CONTROL VALVE 2 1627 CFH) 0 1 1 -1/2'" 244 MBTUH I 1/2" CW(2) BACK SERVICE L_J 1 /2 HW(2) 3/4" CW(5) 1 "(90 CFH) 1 /2 CW(2) COFFEE MAKER 4 MU -1 320 MBTUH c-Ill, L_ J 2'(627 CFH) 3/4° CW(3 FU) 2 ° (410 CFH) —1-1/2"(320 CFH) ROOF LEVEL DRINK DIPENSER 2ND FLOOR FS -1 ROOF LEVEL C0 2ND FLOOR J NOTES: 1. PROVIDE UNE SIZE CLEANOUTS 2. CHANGE 2" VENT HEADER TO 2 TO MALL VENT. UPC TABLE 7 -5 PER UPC TABLE 7 -6 WHERE NECESSARY 1/2" IF HORIZONTAL LENGTH EXCEEDS 40' FOOTNOTE. 3 ° (1037 CFH) 0 REGULATOR SETTING @ 0.5 PSI TOTAL GAS DEMAND = 1037 CFH PIPE LENGTH = 300 FT TOTAL DEVEL. LENGTH 300 FT X 1 GROUND FLOOR GAS METER ALCOVE PROVIDE EARTHQUAKE VALVE CONTRACTOR TO FILED VERIFY THE LOCATION .25- 'E: CODE COMPLI. G f AIJ eJ O VE ; VIAR 2 0 2r1 0F EXPLRES 4 -17 -2009 r--) 74r-- \ )(c MAR 13 2008 PERMIT CE6TEa CHAR BROIL RANGE 95 MBTUH PIZZA OVEN 80 MBIUH FRYER 244 MBTUH FOUR GB RANGE REVISION ISSUED FOR PLAN CHECK ISSUED FOR BIDDING ISSUED FOR PERMIT ISSUED FOR CONSTRUCTION ISSUED FOR DESIGNED BY: - DRAWN BY - 31dO REVIEWED BY: - DATE: 03.06.2008 JOB NUMBER: 07936 FILE #: P1.1.DWG KENN BUTTS A.I.A. Butts / 1<<< <<<<<< Kenneth L. Architect 124 STAGECOACH ROAD BELL CANYON, CA- 91307 TEL, (818) 999 4272 FAX. (818) 999 4321 3nSSI Y V KULKARNI, P.L. (MECHANICAL AND ELECTRICAL) 39371 SPANISH BAY PLACE DAVIS, CA 95616 E -MAIL YASHAVANTOCOX.NET FOR PROJECT COORDINATION CONTACT PROJECT MANAGER KIM KIMIAGAR 310 576 1553 PHONE 310 576 1569 FAX 80 ll - ZOI REVISION ISSUED FOR PLAN CHECK ISSUED FOR BIDDING ISSUED FOR PERMIT ISSUED FOR CONSTRUCTION ISSUED FOR DESIGNED BY: - DRAWN BY - 31dO REVIEWED BY: - DATE: 03.06.2008 JOB NUMBER: 07936 FILE #: P1.1.DWG SHEET TITLE: PLUMBING FLOOR PLAN SCALE: AS NOTED SHEET NUMBER: F1.1 1<<< <<<<<< 3nSSI HEALTH DEPARTMENT SUBMITTAL PERLIMINARY SUBMITTAL PLAN DEPARTMENT SUBMITTAL & WESTFIELD FINAL SUBMITTAL 31VO 90 -60- ! 0I 80 ll - ZOI 80- 90 -E01 ISSUED FOR APPROVAL ISSUED FOR PLAN CHECK ISSUED FOR BIDDING ISSUED FOR PERMIT ISSUED FOR CONSTRUCTION ISSUED FOR DESIGNED BY: - DRAWN BY - CHECKED BY: - REVIEWED BY: - DATE: 03.06.2008 JOB NUMBER: 07936 FILE #: P1.1.DWG SHEET TITLE: PLUMBING FLOOR PLAN SCALE: AS NOTED SHEET NUMBER: F1.1 ANDLORD NOTES: 1. TENANT SHALL CONNECT GREASE WASTE PIPE TO LANDLORD PROVIDED COMMON 4" GREASE WASTE PIPE THAT TERMINATES INTO A COMMON GREASE INTERCEPTOR OUTSIDE THE BUILDING IN THE PARKING LOT. 2. ALL TENANTS ON THE GROUND FLOOR REQUIRING BELOW GRADE WORK SHALL COORDINATE WITH LANDLORD PRIOR TO ANY SLAB DEMOLITION. TENANT SHALL COORDINATE WITH LANDLORD TO PROVIDE OPPORTUNITY FOR SPECIAL INSPECTION AND PHOTOGRAPHIC DOCUMENTATION BY LANDLORD OF BELOW GRADE WORK PRIOR TO THE COVERING UP OF SUCH WORK. TENANT SHALL BE RESPONSIBLE FOR RECONSTRUCTION AND PATCHING OF THE SLAB -ON -GRADE SYSTEM, INCLUDING GRAVEL LAYERS, VAPOR BARRIER, AND CONCRETE. C " S E C F i 5 � 17 i FIE C' LD C"OOINA4 E S11N 4" W LINE D AN I FIELD VERIFY THE LOCA11bN LI 39 KITCHE 38 r 4 I 161 I 0 ISM - f W LINE Fla ur FIELD VERIFY THE EXISTING 3" VENT LINE FIELD COORDINATE AND FIELD VERIFY THE LOCATION — - WARE111lA4HING =_` PREPERATION 1 I o 1 - WALIR 1N-cooLER_ t DRAWING NOTES: cD SEE ARCHITECTURAL DRAWINGS FOR MOUNTING DETAILS. 0 SEE KITCHEN EQUIPMENT SCHEDULE AT SHEET K FOR MORE INFORMATION. PLUMBING FLOOR PLAN (WASTE & VENT) SCALE: 1/4 " =V -0 " S E R V PLUMBING FLOOR PLAN (WATER& GAS) C 0 R R EpI1 Np}} 2" W LINE I FIELD COORDINATE AND FIELD i VERIFY THE LOCATION 0 6I SERVICE AR KITCHE WAC - Tn _ • 1.. �.. WAREWASHING 1 11666 DRAWING NOTES: • SEE ARCHITECTURAL DRAWINGS FOR MOUNTING DETAILS. • SEE KITCHEN EQUIPMENT SCHEDULE AT SHEET K FOR MORE INFORMATION. qT0I VERIFY THE LOCATION ( DRY STORAGE . 7FTEPeR >N REVIEWED FOR _ COOS COMPLIANCE I APPROVED 2 MAR 2 0 1;O 3 City Of Tukwila OIL . ING �� r [EXPIRES 4 -17 -20091 SCALE: 1/4"=1"-0" F. y MAR 13 2008 POT CENTER 1