Loading...
HomeMy WebLinkAboutPermit PG08-080 - WESTFIELD SOUTHCENTER MALL - SUSHI ITTOSUSHI ITTO 2600 SOUTHCENTER MALL PG08-080 Parcel No.: 6364200010 Address: Suite No: CitAf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PLUMBING /GAS PIPING PERMIT 2600 SOUTHCENTER MALL TUKW Permit Number: Issue Date: Permit Expires On: PG08 -080 05/21/2008 11/17/2008 Tenant: Name: Address: Owner: Name: Address: SUSHI ITTO 2600 SOUTHCENTER MALL FC -13 , TUKWILA WA WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD CA Contact Person: Name: DAVID HUANG Address: 2414 1 AV #705 , SEATTLE WA Contractor: Name: ANCOR INC Address: 831 JAMES ST 2ND FLOOR , SYRACUSE NY Contractor License No: ANCORI *054N1 Phone: Phone: 206 713 -1823 Phone: 315 - 233 -1300 Expiration Date: 06/06/2009 DESCRIPTION OF WORK: ROUGH -IN AND CONNECTION FOR GAS SUPPLY, WATER, AND SEWAGE FOR KITCHEN FIXTURES Value of Plumbing /Gas Piping: Fees Collected: $35,000.00 $762.00 Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 FIXTURE TYPE AND QUANTITY Plumbing Bathtub or combination bath/shower 0 Bidet 0 Clothes washer, domestic 0 Dental unit, cuspidor 0 Dishwasher, domestic, with independent drain 0 Drinking fountain or water cooler (per head) 0 Food -waste grinder, commercial 0 Floor drain 6 Shower, single head trap 0 Lavatory 0 Wash fountain Receptor, indirect waste 0 Sinks 5 Urinals 0 Water Closet 0 0 Plumbing (cont.) Building sewer and each trailer park sewer 1 Rain water system - per drain (inside bldg) 0 Water heater and/or vent 0 Industrial waste treatment interceptor, including its trap and vent, except for kitchen type grease interceptors 0 Repair or alteration of water piping and/or water treatment equipment 0 Repair or alteration of drainage or vent piping 0 Medical gas piping system serving (1 -5) inlets /outlets for a specific gas 0 Medical gas piping (6 +) inlets /outlets 0 Gas Piping Gas piping outlets (0 -5) 4 Gas piping outlets (6 +) 0 * *continued on next page ** doc: UPC -10/06 PG08 -080 Printed: 05 -21 -2008 City ofTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: PG08 -080 Issue Date: 05/21/2008 Permit Expires On: 11/17/2008 Permit Center Authorized Signature: Date: '4" v I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this plumbing /gas piping permit. Signature: Print Name: Date:. 2/ -C2V This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -10/06 PG08 -080 Printed: 05 -21 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS 2600 SOUTHCENTER MALL TUKW SUSHI ITTO Permit Number: Status: Applied Date: Issue Date: PG08 -080 ISSUED 03/13/2008 05/21/2008 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 12: ** *PUBLIC WORKS DEPARTMENT CONDPI'IONS * ** 13: Waste line shall be connected to the existing outside grease interceptor. * *continued on next page ** doc: Cond -10/06 PG08 -080 Printed: 05-21 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Date: 2 7_ c.. doc: Cond -10/06 PG08 -080 Printed: 05-21 -2008 CITY OF TUKWIL Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us SWE411140CATIt7 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: 4..6420 — 0 0 to Site Address: 2&) $CUif /G.6lr'g 'MALI_ , •_ "F613_ Suite Number: FG /3 Floor: 2AjD Tenant Name: S LIS H 1 .Z TTD New Tenant: Pr/ Yes 0 .. No Property Owners Name: a� t- 14AC�P_4.,1 / r l ez it Mailing Address: 63 C x,k,,r Name: j7,4 v 1,) MAIW (� Mailing Address: Z' t 1 + 1sT A" VE # 7o.� E -Mail Address: eAkii U & meefaSvs-tad; ) , C oM Company Name: -7"-BP "4 City Day Telephone: -56%n6 City Fax Number: 1V.4— State `l rfi Zip 7- 16- 7/3 -/8 Z 3 State Zip 2.-06 374 -375- z Mailing Address: City Contact Person: - - _ - - Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Company Name: Mailing Address: Contact Person: E -Mail Address: State Zip Expiration Date: e staMeedllyArchitiet ofReco /vloDOS V 5 r .ago 2,414- ZSr INC ciAur 70.E DAV/.o HUAAi det vl d ni opus vsSItd%o_. cep,•, City Day Telephone: Fax Number: wA ?Fiat State Zip Z -6 —7/3 -1823 2o6 ?74- ?7_s-2 SINE ans musfb wstampe ' y�Zrs .e ...i Company Name: Mailing Address: Contact Person: E -Mail Address: Q:Wpplications\Fottns- Applications On Lined -2006 - Permit Application.doc Revised: 9 -2006 kh City Day Telephone: _ Fax Number: - - State Zip Page l of 6 EI � D1NG �±P WRMI =T' INF0 ION � (- 206=43143 f7C Valuation of Project (contractor's bid price): $ /4r, 000 Existing Building Valuation: $ Scope of Work (please provide detailed information): 772,140-441" I prove nI2dS U $Z 4 sF rite/ti �f�r GEC -r600( S -V , ce Ste flier U ril es-f-0 -4od Gtr u r-r vVork i vi kee s fi Z44 xi-tc./441 Fioc,i, t1'l&chatsc�� eJe67), ca 1, ((:51, ! � otiote /Ut31b1✓1 i net. , vl'f l d t- Will there be new rack storage? ❑ Yes o If yes, a separate permit and plan submittal will ;e required. Prompvide Ail Building Areas in Squa�r_e_�@Eootage°Belowe °-aa ie a 4.4. }^..: n (V ',. a r i a +w ° ;.t*, o$q-'9f'A -'67 t4rJ+ Ai' Ai° 9K•, r tr 'z 4 6 'o o .g- �' o a> .Eicistmg :..:o Q b 44 a ItiteridrRemodel a Addition to :"'l Existing.,; °' �v,-°4Structure ,,° 4'6° t= x °.t , 9, ° jg g" : "o y- �a.t,tNe " Type of ° Construction per d .;IBC � a S;s T' e of ° O cu anc o q P YP:' -° =,IBC .Floors .44:0:,`,..-,s, . ° °k a. a 4 A t1j L j 2MFloor,ta �s � B« >: J. : 9 D.pav -Qo t° o 8``... , qt° Flooti f, , .BL gt 4,a, ACC �'! tY�. `. AI b, AC APi L ✓� `• 1h' Floors A�.' �. ° thru °-. - ° °e a° n ggG, -.6B Basement el n.° ' �^ � pfd a a I A, .4. a.'3�. ,a. ?\Accessory; Structure* '.. '. \Attached Garage .. . ' �` \ Zetaehed Garage Attached Carport g:b B- Q � ,,,, : Detached Carport . 0. Covered Deck. Uncovered Deck " s: o ,, ° off° PLANNING DIVISI Single family buildi ootprint (area of the foundation of all structures, plus any decks er 18 inches and overhangs greater than 18 inches) *For an Accesso dwelling, provide the following: Lot A *Pr (sq ft): Floor area of principal dwelling: \ Floor area of accessory dwelling: de documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If `yes ", explain: FIRE PROTECTION/HAZARDO 3 S MATERIALS: Sprinklers [Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes [( No If 'yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:\Applications \Forms - Applications On Line 3 -2006 - Permit Application.doc Revised: 9 -2006 Page 2 of 6 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: -r 13 9 City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Plumbing work (contractor's bid price): $ y D 0 Valuation of Gas Piping work (contractor's bid price): $ (10." 0 v 6 „id Scope of Work (please provide detailed information): rd ix. - (i Lt,4t1 _ iali s �. _ J•,. ,L.. /� V Building Use (per Int'l Building Code): / - c $aYo" / f Occupancy (per Int'l Building Code): A 3 s Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: FixtureTYP e Wei. '�QtY 1�iac'tu e: Pe :.. rY QtYFira ture,, pe. _a Ty :.' �tY ; -< Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain Sinks S Dental unit, cuspidor - Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Additional medical gas inlets /outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets /outlets for specific gas Q:\Applications\Forms- Applications On Line 3 -2006 - Permit Application.doc Revised: 9 -2006 Page 5 of 6 Ch iy R.._.ii Y il4a�� Yq,{y. 6 rv,o Atny • . Cy 1f`YL,'TN V}f yitFv�'r.p:�i:$:' •fiy.A�'! {PE:RMIT APPLICA�TIONpNOTES Applicablelto allper- mats >In tlusap Ilcahon { Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Date: 3/112-0 ad Day Telephone: C.r)6 - 7 T 3- (c 23 561£ wA qs r Zj Mailing Address: 2414 1 r AuE UNCT Tor City State Zip Date Application Accepted: 03A 147t Date Application Expires: oil L ,21 Staff Initials: Q:\Applications'Forms- Applications On Line \3-2006 - Permit Application.doc Revised: 9 -2006 1.F Page 6 of 6 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www. ci. tukwila. wa. us SET RECEIPT RECEIPT NO: R08 -01702 Initials: JEM Payment Date: 05/19/2008 User ID: 1165 Payee: SUSHI PACIFIC SUPPLIERS, INC. Total Payment: 4,452.50 SET ID: 0519 SET NAME: SUSHI ITTO SET TRANSACTIONS: Set Member Amount D08 -135 EL08 -253 M08 -079 "' TOTAL: 1,958.50 934.00 856.00 704.00 4,452.50 TRANSACTION LIST: Type Method Description Payment Check 5946 ACCOUNT ITEM LIST: Description TOTAL: Amount 4,452.50 4,452.50 Account Code Current Pmts BUILDING - NONRES ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES GAS - NONRES MECHANICAL - NONRES PLAN CHECK - NONRES PLUMBING - NONRES STATE BUILDING SURCHARGE 000/322.100 1,594.00 000.322.101 00.0 574.00 000.345.832 00.0 360.00 000.322.103 00.0 92.00 000.322.102 00.0 496.00 000/345.830 738.00 000.322.103 00.0 594.00 000/386.904 4.50 TOTAL: 4,452.50 2591 05/19 9711 TOTAL 4452.50 Doc: RECSETS -06 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http. //www ci. tukwila. wa. us SET RECEIPT RECEIPT NO: R08 -00749 Initials: JEM Payment Date: 03/13/2008 User ID: 1165 Payee: MODUS V STUDIO LLC Total Payment: 1,361.60 SET ID: S000000980 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount D08 -135 1,036.10 EL08 -253 143.50 M08 -079 124.00 trefkmougm 58.00 TOTAL: 1,361.60 TRANSACTION LIST: Type Method Description Amount Payment Check 1042 ACCOUNT ITEM LIST: Description TOTAL: 1,361.60 1,361.60 Account Code Current Pmts ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES 000.345.832.00.0 143.50 000/345.830 1,218.10 TOTAL: 1,361.60 1nTAL 1361,0 3 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit PERMIT NO. A/ � U (206)431 -3 Proj �" Z tc,,rl 1+f 0 4. Type of Inspection: �r ti+4 \..) Address: 2&X7 n14 ( Date Called: f/,1 5(i :.,klv Vir,ktirij Special Instructions: Date Wanted: a.m. ' Requester: Nvf'L (Atilk:A2 4,,vsd 5;Alei. Phone No: 3i —ZS1 - ( 5/ .57 KIApproved per applicable codes. ElCorrections required prior to approval. COMMENTS: 4. 6'4f 1' NA 1 Sp€rele F ,-.2, -% ! tw11%0', ( i Nt( 0.,(0-7...- rft,..,44.) fitsid 17,/ f/,1 5(i :.,klv Vir,ktirij Tit it ; gcSS» (l 1;41-0,- P41 7— /g' 0 Nvf'L (Atilk:A2 4,,vsd 5;Alei. h!44 fi° h,L toWyklfill Inspector: Date: 21 -41 ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD Retain a copy with permit PERMIT NO. Proje : S 2 I H ITr° Type of Inspection: -(0 AS Address: a- m A-11 Date Called: &4> IZe.c . ci, Special Instructions: Date Wanted: � � `."m i fo ` `-' /�C p., Requester: Phone No: alApproved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: &4> IZe.c . ci, 11 'ivc( 441d Al+9.aa -t/( roe- , C'asipi re T e 7+, t Sd//.,... ' e- Inspector: Date: ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: a INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION I< 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Eoeo Project: Sz /eh _1770 Typ f Inspection: goPf4-fk/ -/h4 h Addrjb j Date Called: Special Instructions: C- 1 2 J Date Wanted: Q � V (,� 7_ a.rrr p.m. Requester: Phone No: %Approved per applicable codes. Corrections required prior to approval. COMMENTS: (,s o4 30 P5t \� Inspector: Date: $60.O0 SPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 112- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 h Proje ? /5■1 //lei Type bf Inspection: . x own -MI 645--PAAr ri A0/ 4 // Date Called. t Special Instructions: Date W nted: -/g 4f) of .m. Requester: Phone No: ,..7/5 —ZS 1-- ./5 rccf- Approved per applicable codes. D Corrections required prior o approval. COMMENTS: 17p4, t 1 t wP4A— -C\01244 642'90 -- Ai o 4--/N eG"- S Q t.., N‘.6 s, ;t ,./- a Inspector: ice—_ u ,•-•` tSkC L Date: ta, t t �� cs El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: -- - -...w a iA�6.y a.1R/\. ire Sprinkler * 0a:fit& • I3ACKFLOW PREVENTION ", - V.✓ DV� AS SEMBLY TESTING REPORT kiNEW /NSrALL.4 rtOA, S TRIAL Na. F DEVI HAZARD ISOLATED TABLE WATER 0 IRRIGA'T'ION i R.P. ®.A ❑ D.C.V.A. ❑ R.P.D.A, L7 D.C.DA. ❑ P.V.R:A. ❑ &VILA. ❑ A.V_B_ ❑ AIR GAP 1S DEVICE INSTALLED PROPERLY? INITIAL TEST RESULTS S ONO , COMMENTS REDUCED PRESSURE ASSEMBLY P S P A_ 1 (A) TIGHT 0CK �! RELIEF VALVE p OPENED AT 3 -O (B) min a paid OLIPFER A -B- m103 pal RELIEF VALVE PASS. FALLU paid LEAKED 0 CHECK #2 TIGHT o LEAKED 0 paid P.V.B.A. AIR INLET OPENED AT _. -ism DID NOT OPEN CI COMMENTS REPAIRS ANTYOR PARTS TEST AFTER REPAIRS RED 11 CHECK PRESS I3ROP UCED PRESSURE ASSEMDLY P.V.B.A. AIR [N ET . CHECK #1 -�=1A) TIGHT 0 OPENED AT / S.V.B.A CHECK PRESS DROP PSID FAILED O RELIEF VALVE UPINED AT (B) min 2 psld SUPPER A-8- p11 paid CHECK la TIGHT ®_ paid PSID / S.V.B_A CHECK PRESS pEtd PSID GAUGE CALIBRATION DATE fir / l Q - DETECTOR METER READING ESTER SIGNATURE ,n7 e ir4.1 _Ed .re COMPANY ADGMESS ___¢ tl____ __ o__,a e TESTER NAME {PRINTED) REPORT RECEIVED BY; EMERALD PIPE LLG LaiirowtatittliRMTRO V1610 1Gx HARBOR. WA 98329 . INfI �q.L TEST PASSED lig FAILED DATE: 8/a1 SYSTEM PSI QO • FINAL TEST PASSED 0 DATE: / / CERTIFICATION D Otlice - •( /9e2 l ' oAusE 7 - x7567 PHONE EteSEAVICE RESTORED Fire Sprinkler Specialist BACKFLOW PREVENTION ASSEMBLY TESTING REPORT a NEW INS TALLAVON S R.P.D.A 0 D.C:V.A. 0 R.P.D.A. 0 D.C.D.A. 4 P.V.B.A. ❑ S.V.B.A, IS DEVICE INSTALLED PROPERLY? OYES ONO - COMMENTS REDUCED PRESSURE ASSEMBLY fNITIAL TEST RESULTS COMMENTS REPAIRS AND /OR PARTS II CHECK PRIM DROP (A) RELIEF VALVT OPENED AT 6''1 (R) min 2 paid BUFFER M825 nin3p31 RELIEF VALVE 241 2327 TEST AFTER REPAIRS IMEMENIMM—ATR INLET CHECK #I TIGHT O Paid LEAKED 0 0 A_V_B. ❑ AIR OAP OPENED AT CHECK #2 PSID TIGHT D psld LEAKED O REDUCED PRESSURE ASSEMBLY NI CHECK PRESS DROP (AI RELIEF VALVE OPBNBD AT BUFFER min 2 psid (0) min 3 el CHECK #1 TIGHT O DID NOT OPEN 0 PRESS DROP PSID FAILED Q PASSED IRO FAILED' ❑ DATE: ' - l Ik / Qc SYSTEM PSI psid CHECK #2 TIGHT 0 GAUGE CALIBRATION DATE .5 / f 0 / 0 ESTER SIGNATURE COMPANY P.V.B.A. / S.V.B.A — FINAL TEST AIR INLET CHECK OPENED AT PSID PRESS DROP PSID PASSED ❑ DATE: / J TESTER NAME (PRINTED) DETECTOR METER READING - ADDRESS REPORT RECEIVED BY; EMERALD FIRE. L r IG PlAIWOR, WA 94 329 CERTIFICATION # jtjs - 2'9 S' .. GAUGE* PHONE B SERVICE RESTORED HERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG08 -080 DATE: 03 -13 -08 PROJECT NAME: SUSHI ITTO SITE ADDRESS: 2600 SOUTHCENTER MALL, FC -13 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: 2 yD� Bui ng"Di'visi n1l Fire Prevention Planning Division Public Wqr�k�s Structural 111 Permit Coordinator 111 £'V\)' 3 (%- O? DETERMINAT ON OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete ❑ DUE DATE: 03-18-08 Not Applicable ❑ Permit Center Use Only . INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS RO ING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 04-15 -08 Not Approved (attach comments) ❑ DATE: Permit Center, Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documentstrouting slip.doc 2 -28-02 Look Up a Contractor, Electrician or Plumber License Detail 411, II Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. License Information License ANCORI *054N1 Licensee Name ANCOR INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601646868 Ind. Ins. Account Id #2 Business Type CORPORATION Address 1 831 JAMES ST 2ND FL Address 2 City SYRACUSE County OUT OF STATE State NY Zip 13203 Phone 3152331300 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 8/21/1995 Expiration Date 6/6/2009 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date ANTHONY, THOMAS J Cancel Date 01/01/1980 Bond Amount ANTHONY, JOSEPH G #2 01/01/1980 22160462 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #2 WESTERN SURETY CO 22160462 05/21/2002 Until Cancelled $12,000.00 06/03/2002 Page 1 of 2 https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= ANCORI *054N1 05/21/2008 PROJECT SUSHI ITTO WESTFIELD SOUTHCENTER PLUMBING PLAN Project number - Date 2008 -03 -07 Drawn by CCM Checked by SRP P -1 Scale 1/4" = 1' - 0" 1._ ' •'4VO TE 73 P -1 NOTE 73 SCALE NONE SCALE 1/4"=1 3 "FD 1 T P) ) \ / \ j rte, i \ WH -1 T L-- 2 „ \ ` I . - v 4 1 ",3 '' 'F 4 - t 4 1‘ 4 PLUMBING SANITARY AND VENT PLAN 0 SANITARY RISER DIAGRAM NOTE 2 A G1N, nl FCO 2 "FD -1 1 3 n I 2 ff NOTE 8 {,> r 3 " 1 - q 7 , 1 NOTE 3 NOTE 74 . �]ja ..J1 P -1 SCALE NONE DOMESTIC WATER RISER DIAGRAM HWH -1 NOTE ET -1 7 „ 60111. Licv UMBING ,� 4Afoa . aD Y AND,. "1" PLAN SCALE 1/4 " = 1' -0" • „ ;,3/4 J1 NOTE 9 j/4" NOTE 72 1„ NOTE 7 3/4 3/4" 2 " FILE COPY Penult No. Mar review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and canons is acknowledged: B Date:, 5-2( 7s City of Tukwila BUILDING DIVISION 7'1P.nPes shall � _. 2f work .,;,itl�oUt prior ade to the scope Tukwila Building approval of n „_,.�� g Division. . ' - ' °vlSionS will require -nay include addinal plan review fees of SEPARATE PERMIT ' REQUIRED FOR: Vii echanicai lectrical 0 Plumbing Gas Piping City of Tukwila PUILDING p VISION , REVIEVVED FOR - CODE COMP APPROVED MAR 2 0 BOO CE71tE4i AL NOTES A . EXISTING CONDI TIONS ARE BASED ON AS -BUILT " DRAWINGS PROVIDED BY THE OWNER. CONTRACTOR SHALL ADJUST TO ACTUAL FIELD CONDI TIONS AT NO ADDITIONAL EXPENSE TO THE OWNER. B. CONTRACTOR SHALL FAMILIARIZE HIMSELF WI TH DEMOL I TION WORK PRIOR TO BIDDING AND START OF WORK. CONTRACTOR IS RESPONSIBLE TO DEMOLISH ALL EXISTING AS REQUIRED FOR INSTALLATION /CONSTRUCTION OF NEW WORK. C. THE CONTRACTOR SHALL OBTAIN A COPY OF THE LANDLORD 'S TENANT CRITERIA MANUAL . TENANT CRITERIA MANUAL REQUIREMENTS SHALL BE INCLUDED IN THIS CONTRACT. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPL YING WITH LANDLORD REQUIREMENTS ,4T NO EXTRA COST TO THE TENANT. D. CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING CONDI TIONS PRIOR TO SUBMITTING HIS BID. NO ADDI TIONAL COMPENSATION WILL BE MADE FOR ANY EXTRAS DUE TO CONTRACTOR 'S FAILURE TO VISIT THE JOBS' TE AND /OR PREDETERMINE ALL EXISTING' CONDITIONS BEFORE SUBMITTING HIS BID. ANY DISCREPANCIES SHALL BE IMMEDIA TEL Y REPORTED TO THE ENGINEER FOR RESOLUTION. E. ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH ALL APPLICABLE GOVERNMENT AND LOCAL CODES. F. PROVIDE ACCESS PANELS AS NEEDED TO ACCESS VAL VES, EQUIPMENT, ETC. LOCA TED ABOVE GYP. CEILINGS. G. PROVIDE TEMPORARY COVERS, CAPS, OR PLUGS ON SANITARY SEWER SYSTEM THROUGHOUT CONSTRUCTION. RAG WADS, DUCT TAPE OR OTHER MAKE SHIFT CAPS ARE NOT ACCEPTABLE. UPON COMPLETION OF CONSTRUCTION, COMPLETELY REMOVE ANY AND ALL OBSTRUCTIONS INSIDE THE ENTIRE DWV SYSTEM, NEW AND EXISTING LINES, BY SNAKING, RODING, 01? JETTING THE SYSTEM IMMEDIA TEL Y PRIOR TO PROJECT TURNOVER TO THE OWNER. B PLLING NOTES- 1 . SPACE RESERVED FOR ELECTRICAL EQUIPMENT. NO NEW WATER PIPING SHALL CROSS THIS AREA WI THIN THE BUILDING. 2. INSTALL WATER HEATER (HWH -1) AND EXPANSION TANK (ET -1) BELOW COUNTER AS SHOWN ON PLANS. * *COORDINATE THE EXACT LOCATION WITH HVAC CONTRACTOR TO AVOID DUCTWORK CONFL ICT* * . SEE TYPICAL DETAIL ON SHEET P-2 . PIPE RELIEF AND CATCH PAN FROM WATER HEATER (HWH -1) TO FLOOR DRAIN (2"FD -1). MAINTAIN A 2" MINIMUM A IR GAP. PROVIDE A CATCH PAN UNDER WATER HEATER AND EXPANSION TANK 3. CONNECT NEW VENT TO EXISTING VENT. VERIFY THE EXACT SIZE AND LOCATION OF EXISTING' VENT PRIOR TO CONSTRUCTION. 4. 1/2" FLEXIBLE CONTINUOUS TYPE K" COPPER TUBING BELOW GRADE FROM TRAP PRIMER (TP -1) TO FLOOR DRAIN (2 "FD -1). NO FITTINGS OR SPL ICES ALLOWED BELOW GRADE. 5. INSTALL TRAP PRIMER (TP 7) IN THE WALL . PROVIDE AN ACCESS PANEL AS NECESSARY. 6. CONNECT NEW GREASE WASTE TO EXISTING GREASE WASTE OF EQUAL OR GREATER SIZE AT REMOVED RESTROOMS. VERIFY EXACT LOCATION, SIZE AND INVERT ELEVATION OF EXISTING GREASE WASTE PRIOR TO CONSTRUCTION. FIELD ADJUST NEW GREASE WASTE ROUTING AS NEEDED TO CONNECT TO EXISTING GREASE WASTE WHILE MAINTAINING PROPER PIPE SLOPE. 7. CONNECT NEW 1 " DOMESTIC COLD WATER LINE TO EXISTING DOMESTIC COLD WATER LINE OF EQUAL OR GREATER SIZE. VERIFY EXACT LOCATION AND SI7F OF EXISTING' DOMESTIC COLD WATER LINE PRIOR TO CONSTRUCTION. FIELD ADJUST NEW DOMESTIC COLD WATER PIPING AS NECESSARY TO CONNECT INTO EXISTING DOMESTIC COLD WATER LINE. PROVIDE AND INSTALL A PRESSURE REDUCING VALVE IF SUPPLY PRESSURE EXCEEDS 60 P. S. I. G. VERIFY AND COMPLY WI TH ANY LANDLORD WATER METER REQUIREMENTS. 8. ROUTE VENT PIPING UNDER FLOOR AND SLOPE TOWARD WASTE AT 1/8" PER FOOT 9. ROUTE PIPING DOWN TROUGH WALL TO CEILING SPACE OF LOWER FLOOR. 70. WATER HAMMER ARRESTORS TO BE SIZED AND INSTALLED PER MANUFACTURERS SPECIFICATIONS. LOCATIONS SHOWN ARE FOR REFERENCE PURPOSES ONLY . 11. ROUTE GREASE WASTE FROM GREASE EXHAUST FAN ON ROOF TO FLOOR SINK. MAINTAIN MINIMUM 2 AIR GAP. SEE SHEET M -X FOR CONINUA TION. 72. CONNECT NEW 3/4" GAS PIPE SERVING 388.6 MBH TO EXISTING 2" GAS LINE PROVIDED BY LANDLORD. INSTALL PRV, GAS COCK, AND AUTOMA TIC SHUT OFF VALVE TO ANSUL SYSTEM IN CEILING SPACE. INSTALL EARTHQUAKE SHUT OFF VALVE IN METER ALCOVE SERVING TENANT SPACE. CONTRACTOR SHALL VERIFY EXISTING DELIVERY PRESSURE PRIOR TO CONSTRUCTION. 13. PROVIDE ISLAND VENTING FOR HAND SINKS, EQUIPMENT NUMBERS 18 AND 35. 74. COORDINA TE ALL PIPING IN WALL PRIOR TO INSTALLATION. 0 ty Of Tukwila N .: DIVISION M O D U S v www.modusystudio.com S T U D I O ARCHITECT 9260 REGISTERE ACT Modus V Studio 2414 1st Avenue, Unit 705 Seattle, WA 98121 David Tzu -Hsiu Huang 206- 713 -1823 Client Name Project Address SUSHI ITTO DAVID TZ11 -HSIU H v, STATE OF WASHINGTON 2600 SOUTHCENTER MALL FC13 TUKWILA, WA 98188 ENGINEERS Schnackel o NewYark 0 Omaha o LoSAngeles o 800 - 581-0963 wwwschnadcel.com EXPIRES 12/21/09 OWNER SUSHI ITTO, SUSHI PACIFIC SUPPLIERS INC. ALBERTO ROMANO 4930 ZAMBRANO ST, CITY OF COMMERCE, CA, 90040 TEL: (323) 278 -9202 FAX: (323) 278 -9212 PERMIT SET SUBMITTAL No. Description P P r' VE D MR 1 9nf1R TUKWILA h'LJt LIU UVLJ111 \ RECEIVED iiiY or T U Vv1LA MAR 13 2008 PERMIT CFMTFR Date PLUMBING FIXTURE SCHEDULE MARK )J itNVf101 DESCRIPTION CONNECTIONS MANUFACTURER/ MODEL NUMBER HW CW V W TP -1 TRAP PRIMER MACHINED OF CORROSION RESISTANT BRASS CONTAINS NO SPRINGS OR DIAPHRAMS, INLET 1/2" MALE NPT, OUTLET 1/2" FEMALE NPT. PRESSURE ACTIVATED PRIMER DELIVERS POTABLE WATER ACROSS AN AIR GAP FUNNEL THEN THROUGH THE DISTRIBUTION UNIT WHEN IT SENSES A PRESSURE DROP OF 5 TO 10 P.S.I.G. -- 1/2" -- -- PRECISION PLUMBING PRODUCTS INC. / P2 -500 MOUNTING HEIGHT MINIMUM MOUNTING HEIGHT OF 12" ABOVE FINISHED FLOOR WHEN FLOOR DRAIN SERVED IS 20' -0' OR LESS DEVELOPED LENGTH FROM UNIT, MOUNT AN ADDITIONAL 12" HIGHER FOR EACH ADDITIONAL 20' -0" OF LENGTH. SUPPLIES DISTRIBUTION UNIT DU-2 FOR 1 OR 2 TRAPS, DU-3 FOR 3 TRAPS, OR DU -4 FOR 4 TRAPS, TO SUPPLY MORE THAN FOUR TRAPS ADD DISTRUBUTION UNIT PAIRS UP TO 8 DRAINS, PROVIDE AG-500 AIR GAP CONNECTION. FD -1 FLOOR DRAIN COATED CAST IRON FLOOR DRAIN, TWO -PIECE BODY, DOUBLE DRAINAGE FLANGE, INVERTIBLE NON-- PUNCTURING FLASHING COLLAR, WEEPHOLES, BOTTOM OUTLET INSIDE CAULK CONNECTION, ADJUSTABLE ROUND SUPER -FLO STRAINER, FLASHING CLAMP WITH 24 "x24" 4 LB. LEAD FLASHING FOR FLOOR DRAINS INSTALLED ABOVE SLABE ON GRADE, 1/2" TRAP PRIMER CONNECTION. -- -- 2" SEE PLANS ZURN / ZN -415 -P STRAINER 5" DIAMETER NICKEL BRONZE FINISH ZURN / TYPE B WASTE CAST IRON P -TRAP UNDER FLOOR FS -1 FLOOR SINK SANI -FLOR RECEPTOR, 12" DIA X 8' DEEP CAST IRON BODY AND SQUEARED HOLE MEDIUM -DUTY GRATE, W/ WHITE ACID RESISTING PORCELAIN ENAMEL INTERIOR AND TOP, ABS ANTI - SPLASH DOME STRAINER, 1/2 GRATE. --- --- 2" SEE PLANS ZURN / Z1950 -2 WASTE CAST IRON P -TRAP UNDER FLOOR WCO WALL CLEANOUT COATED CAST IRON CLEANOUT TEE, HUB AND SPIGOT CONNECTION, BRONZE PLUG. -- -- -- SEE PLANS ZURN / 21468 FCO FLOOR CLEAN OUT ZURN MODEL #ZB -1400 DURA - COATED CAST RION BODY. "LEVEL -TROL" ADJUSTABLE FLOOR CLEANOUT. INSIDE CAULK CONNECTION WITH GAS AND WATER TIGHT ABS TAPERED THERAD INTERNAL PLUG ADJUSTABLE HOUSING. HEAVY -DUTY SCORIATED SECURED ROUND TOP, POUSHED BRONZE FINISH, INSTALL FLUSH WITH FINISHED FLOOR. - - - - ZURN #ZB -1400 a� a [TEM NO. I SUPPLIER )J itNVf101 DESCRIPTION 1 PLUMBING GAS NOTES 33>i 'OWNER 'OTHERS _LO H' aloal WASTE 1 ' N NO] nia 1 ■ ■ STOCKHAM B -100 1 3 COMPARTMENT SINK BALL JENKINS 1 -1 /2" - -- 902A DIRECT WASTE 2 r•- -.11 BA150 STOCKHAM 1 SPLASH MOUNT FAUCET 1/2" 1/2" JENKINS 4092 624-C 4093 3 ■ ■ F2974 1509 1 MOP SINK G -931 B -309 2° HAYS 43-45 - 2510 - 0.50 -P /T DIRECT WASTE 4 ■ • 1 MOP SINK FAUCET 1/2" 1/2" , STRAINER 6 or- -1 LI 1 UNDER MOUNT PREP SINK ®D -1 DRAIN AND MARK 1 -1/2" DUMESTIC WATER METER INDIRECT WASTE 7 op- -41 —1)— 1 DECK MOUNT FAUCET 1/2" 1/2" FIRE MAIN V.C.P. VITRIFIED CLAY PIPE F 9 ■ ■ CI CAST IRON 1 DROP —IN 2 WELL HOT FOOD UNIT LE. INVERT ELEVATION 1/2" WALL CLEAN DUT N.LT.C. INDIRECT WASTE 16 ■ - 1 CHAR —BROIL 3/4" 96,000 18 : ■ 1 HAND SINK 1 -1/2" DIRECT WASTE 19 ■ ■. 1 DECK MOUNT FAUCET W/ FOOT VALVES 1/2" 1/2" 24 ■ ■ 1 GRIDDLE 3/4" 60,000 25 ► ■ 1 4 BURNER RANGE 3/4" 88,000 27 ► ■ 1 DEEP FAT FRYER 3/4'' 110,000 28 - ■ 1 RICE COOKER j 3/4° 34,600 _ 35 ■ ■ 1 HAND SINK 1 -1/2" DIRECT WASTE 36 P.- -4 1 DECK MOUNT FAUCET W/ FOOT VALVES 1/2" 1/2" 43 .- ■ 1 WATER HEATER 53 ► ■ 1 UNDER COUNTER ICE MACHINE 1/2" 1/2" INDIRECT WASTE 54 ■ ■ 1 SODA DISPENSER 1/2" 1/2" INDIRECT WASTE 55 ► ■ 1 JUICE DISPENSER VALVE SCHEDULE TYPE MANUFACTURER THREADED /FLANGED PIPING SOLDERED/BRAZED PIPING 2" AND SMALLER 2 -1/2 AND LARGER 3" AND SMALLER GATE JENKINS 47 -C 651 -C 1242 -C MILWAUKEE 148 2885 115 STOCKHAM B -100 G -623 13-108 BALL JENKINS 901A - -- 902A MILWAUKEE BA100 - -- BA150 STOCKHAM S- 216- BR1 -R -T - -- 9- 216- BR1 -R -S CHECK JENKINS 4092 624-C 4093 MILWAUKEE 509 F2974 1509 STOCKHAM B -319 G -931 B -309 AUTOMATIC BALANCING HAYS 43-45 - 2510 - 0.50 -P /T N.A. N.A. NOTES: 1. VALVES MATERIAL (BODIES, DISC, GASKETS, UNINGS, PACKINGS, ETC.) SHALL BE APPROVED FOR THE SERVICE IN WHICH THEY ARE INSTALLED 2. VALVES SHALL BE LINE SIZE UNLESS OTHERWISE INDICATED. 3. VALVES SHALL BE EQUIPPED WITH ACCESSORIES AS REQUIRED. PROJECT MBOL_ PLUMBING DETAILS AND SCHEDULES Project number - P L U M B I N G SYMBOL DESCRIPTION SYMBOL DESCRIPTION VOLTS SANITARY DRAIN ABOVEGROUND ----TIT() FLOOR CLEAN DUT 12 49 SANITARY DRAIN DELOWGROUND --- 010 GRADE CLEAN DUT A.O. SMITH MODEL DEL -30 GREASE WASTE BELUWGROUND 2 CLEAN DUT GW_-=_- co l - -•--• — - VENT LINE VTR VENT THROUGH ROOF STURM DRAIN ABOVEGROUND - --I01---- VACUUM BREAKER s— STORM DRAIN BELUWGRUUND ❑❑ BALL VALVE s— COLD WATER (CW) C. GLOBE VALVE HOT WATER (HW) —(-I— CHECK VALVE - - -- GAS LINE PRESSURE REGULATING VALVE (PRV) G —1411— UND]N , STRAINER Q PRESSURE RELIEF VALVE LI ®D -1 DRAIN AND MARK DUMESTIC WATER METER MIXING VALVE (g)RD ROOF DRAIN —1)— GAS COCK ODS DOWN SPOUT FIRE MAIN V.C.P. VITRIFIED CLAY PIPE F I--I WH WALL HYDRANT CI CAST IRON -r) VALVE IN RISE LE. INVERT ELEVATION WALL CLEAN DUT N.LT.C. NOT IN THIS CONTRACT wrn PROJECT SUSHI ITTO WESTFIELD SOUTHCENTER PLUMBING DETAILS AND SCHEDULES Project number - Date 2008-03-07 Drawn by CCM Checked by SRP P -2 Scale NO SCALE - A ELECTRICAL WATER HEATERS MARK LOCATION KW GAL /HR © 90 DEGREE RISE ELECTRICAL STORAGE CAP MANUFACTURER REMARKS VOLTS PHASE HWH -1 SEE PLANS 12 49 240 3 30 GALLONS A.O. SMITH MODEL DEL -30 EXPANSION TANKS MARK LOCATION SERVES MINIMUM ACCEPTANCE WORKING PRESS (PSI) SIZE (APPROX) MANUFACTURER REMARKS ET -1 SEE PLANS DOM. HW 2.1 150 10 "0x10 3/8" AMTROL MODEL ST -5 —C FIXTURE UNIT TABULATION FIXTURE COLD HOT VALVE WATER CLOSET 10 -- TANK WATER CLOSET 5 -- URINAL 5 -- LAVATORY /SINK 1.5 1.5 JANITOR'S SINK 3 3 SHOWER /BATHTUB 2 2 PDI SIZE PIPE SIZE FIXTURE UNIT LOAD A 1/2" 1 -11 B 3/4" 12 -32 C 1" 33 -60 D 1 -1/4" 61 -113 E 1-1/2" 114 -154 F 2" 154 -330 MEMBRANE CLAMP AS REQUIRED FOR DEPTH OF SEWER SANITARY OR STORM SEWER LINE PROVIDE ROUND SECURED NICKEL BRONZE ADJUSTABLE TOP WITH "CO" CAST IN COVER. PROVIDE CLEANOUT TOP WITH VARIATIONS SUITABLE FOR FLOOR COVERING (CARPET MARKER, RECESSED FOR TILE, SCORIATED FOR UNFINISHED FLOORS). PROVIDE BRONZE PLUG IN PVC BODY. HUB AND SP /GOT PVC PIPE BELOW FLOOR • h 1 NOT TO SCALE • SLOPE FLOOR TO FLOOR DRAIN TRAP WATER LEVEL NOT TO SCALE FLOOR SLAB ON GRADE • - . LONG SWEEP ELBOW AT END OR TURN OF RUN FLOOR CLEANOUT DETAIL FLOOR DRA /N FLOOR DRAIN DETAIL SAME SIZE AS SEWER UP TO 4" MAXIMUM 11(IEIG•HTH COMBINA 770N WYE AND BEND IN RUN. EN TER TOP OF P /PE C{ DIRECTION OF FLOW LOCATE AT BUILDING EXIT, AT ENDS OF RUNS, AT TURNS OF PIPE GREATER THAN 45 DEGREES, AT 50' INTERVALS ON STRAIGHT RUNS, AND WHERE SHOWN ON PLANS. PROVIDE BACKFILL PER ARCHITECTURAL SPECIFICATIONS. LOCATE CLEANOUTS WHERE THERE IS 18" CLEAR AROUND. CONSULT LOCAL CODES FOR OTHER FCO REQUIREMENTS. PD/ 5/ZE 'A 1 /NSTALL PER PDI I STANDARDS AND MANUFACTURERS INSTRUCTIONS SINGLE FlXfURE /F HORIZONTAL BRANCH IS LESS THAN 20' HOT OR COLD WATER SUPPLY IF HORIZONTAL BRANCH /5 LESS THAN 20' LONG, PROVIDE ONE WHA AT END OF LINE IF BRANCH IS GREATER THAN 20' LONG, PROVIDE ANOTHER WHA IN MIDDLE, EACH S /ZED FOR HALF THE F/X7URE UNITS MULTIPLE FIXTURES PC TO PROVIDE WATER HAMMER ARRESTERS BY SIOUX CHIEF, PRECISION PLUMBING PRODUCTS, WATTS OR APPROVED EQUIVALENT WITH PISTON AND 0 —RING CONSTRUCTION, HAVING PDI #WH -201, ASSE #1010 AND ANSI #A112.26.1M CERTIFICATION. INSTALL IN HORIZONTAL OR VERTICAL POSITION, BUT NEVER UPSIDE DOWN. INSTALL IN LINE WITH WATER FLOW DIRECTION IF POSSIBLE. SIZE THE UNITS AS SHOWN ON THE DRAWINGS AND /OR PER THE TABLES SHOWN ABOVE. WATER HAMMER ARRESTERS NOT TO SCALE HOT WATER -- GATE VALVE DIELECTRIC UNION WATER HEATER FLOOR NOT TO SCALE ~. p n ° - 4 • DOMESTIC WA TER SUPPLY TEMP. AND PRESS. RELIEF VALVE DRAIN VAL VE - - , - ' - _ Y a - s. COUNTER TOP S 7 DRAIN LINE TO TENANT'S PLUMBING SYSTEM ELECTRIC HOT WATER HEATER DETAIL EXPANSION TANK DE COMPLIANcE MAR r 0 �01A r.e;�gT Otle OF Tukwil 8Uxt rynur _ r apt i CITY TU MAR 13 2008 PERMIT CENTER M O D U S v www.modusystudio.com S T U D I O ARCHITECT 9 260 Modus V Studio 2414 1st Avenue, Unit 705 Seattle, WA 98121 David Tzu -Hsiu Huang 206- 713 -1823 Client Name Project Address SUSHI ITTO 2600 SOUTHCENTER MALL FC13 TUKWILA, WA 98188 RECISTEktO ARCHITECT DAV10 =� TZU-HSIU HIM STATE OF WASHINGTO ENGINEERS Schnackel engineers. o NewYork o Omaha Q LosMgeles o 800-581-0963 www.schnackel.com EXPIRES 12/21/09 OWNER SUSHI ITTO, SUSHI PACIFIC SUPPLIERS INC. ALBERTO ROMANO 4930 ZAMBRANO ST, CITY OF COMMERCE, CA, 90040 TEL: (323) 278 -9202 FAX: (323) 278 -9212 PERMIT SET SUBMITTAL No. Description Date PROJECT SUSHI ITTO WESTFIELD SOUTHCENTER PLUMBING SPECIFICATIONS Project number - Date 2008 -03 -07 Drawn by CCM Checked by SRP P -3 Scale NO SCALE SECTION 15050 BASIC MECHANICAL MATERIALS AND METHODS PART 1 - GENERAL 1.1 SUMMARY A. Labor, materials, tools, and services for a complete instal /ation of equipment and system contained in the Contract Documents. B. Principal features of the work included are: 1. Plumbing system and related piping insulation. 2. Domestic water piping and connections. 3. Limited area fire protection (sprinkler system) when app/ icab le. 4. Excavating and backfi /ling for mechanical work; coordinate with Section 02300. 5. Anchor bo /ts, sleeves, supports and similar items to be built into concrete or masonry. 6. Preparation and submittal of shop drawings and product data. 7. Maintaining a record set of blue /ine prints and marking them to indicate locations of concealed items, and deviations made to suit conditions and production of mechanical as built (record) drawings. 8. Operation and maintenance manuals shall be provided for all equipment. 1.2 JOB CONDITIONS A. Submittal of bid implies bidder has read applicab /e paragraphs of the specifications and wi l l be bound by their conditions. 1.3 LOCAL CONDITIONS A. Conform with local conditions. Coordinate with local utilities on size of utility services. 1.4 INTENT A. The contract documents (drawings and specifications) describe the mechanical work of this project. Any item mentioned in one part shall be as binding as though mentioned in both. B. The contract documents form a guide for a complete mechanical instal lotion. Where an item is reasonably necessary but not specifically mentioned, such as duct hangers or transitions, piping offsets, drains, etc., for a complete system, provide same. C. Mechanical layouts indicated on drawings are diagrammatic on /y. Exact locations of ducts, pipes, and equipment shall be governed by the drawings of related trades. 1.5 DEVIATIONS A. No deviations from specifications and drawings shall be made without full know /edge and written consent of Construction Manager. B. Should Contractor find, during progress of work, conditions which dictate the modification of any particular requirements, report such item promptly for decision or instructions. 1.6 QUALITY ASSURANCE A. Comply with applicable local, state and federal codes. B. Comp /y with applicable requirements of recognized industry associations which promulgate Standards for the various trades. (see individual Sections of Division 75). C. Employ only qualified journeymen for this work. Employ competent, qualified mechanics to supervise the work. 1.7 CODES AND STANDARDS A. Perform work specified in Division 75 in accordance with the applicable codes and standards listed below, and such standards that may be specified in other sections. When these specifications are more stringent, they take precedence. In case of conflict, obtain a decision from the Construction Manager. 1. NFPA 54: National Fuel and Gas Code. 2. NFPA 90,4: Air Conditioning and Ventilation Systems. 3. NFPA 101: Life Safety Code 4. Applicable State Building Code. 5. Applicable State Mechanical Code. 6. Applicab /e State Plumbing Code. 7. Handicapped Code ANSI A117.1 and ADA. 8. App /icab /e State Energy Code. 9. AGA: American Gas Association. 10. ANSI: American National Standards Institute. 11. ARI: American Refrigeration Institute. 12. ASHRAE: American Society of Heating, Refrigeration and Air Conditioning Engineers. 13. ASME: American Society for Mechanical Engineers. 14. ASTM: American Society for Testing and Materials. 15. MSS: Manufacturer's Standardization Society of the and Air Conditioning 76. NEMA: National Electrical Manufacturers' Association. 17. NFPA: National Fire Protection Association. 18. SMACNA: Sheet Meta/ and Air Conditioning Contractors' National Association. 19. UL: Underwriters' Laboratories, Inc. 1.8 COORDINATION A. Carefully examine specifications and drawings to be thorough /y familiar with items which require plumbing or HVAC connections and coordination. B. Coordinate with other Divisions to leave proper chases and openings. P /ace outlets, anchors, sleeves, and supports prior to pouring concrete or installation of masonry work. 7.9 SUBMITTALS A. Submittals are only required for specific items of equipment or material listed in individual sections of these specifications. B. Within 15 days after award of contract for this work, submit a list of proposed manufacturers (of equipment or material to be used) for approval. Submit this list before submittal of shop drawings and product data, and obtain approval before submitting required items. C. Shop Drawings (Not required for Owner furnished equipment). 1.1a DEL I VERY AND STORAGE A. Insofar as possible, deliver items in manufacturer's original unopened packaging. Where that is not practical, cover items with protective materials to keep them from being damaged. Use care in loading, transport, unloading, and storage to keep items from being damaged. B. Store items in a clean, dry p /ace, and protect from damage. 1.11 FIRE RATINGS A. Materials used anywhere in the work must have NFPA ratings as fo /lows: 7. Flame Spread - Not over 25. 2. Smoke Developed - Not over 50_ 3. Fuel Contributed -- Not over 25. B. Materials shall be "Self -Extinguishing". 1.12 PERMITS AND FEES A, Obtain, pay for, and deliver permits, certification of inspection, and other such items required by the authorities having jurisdiction. Deliver certifications to the Construction Manager prior to Final Acceptance of the work. An inspection certificate for each class of work requiring inspection must be submitted prior to or with the final payment invoice. The responsib /e trade contractor must make application for the inspection, coordinate same and pay the required inspection fee. 1.13 EXTENDED WARRANTIES A. Work furnished under the Contract shall be warranted against defects in workmanship and (Contractor furnished) materials for a period of not less than one (7) year, or as otherwise specified from the date of Final acceptance of the installation. Defects of workmanship developing during this period shall be remedied, and defective material rep /aced, without additional cost. When defects in a Trade Contractor's work causes damage to the work of other Trade Contractors', such damage shal l be repaired by the Trade Contractor causing damage and work restored to its original condition, at the expense of the Trade Contractor that caused the damage. PART 2 - PRODUCTS 2. 1 MATERIALS AND EQUIPMENT A. Within the Contract Documents relating to mechanical work, manufacturers; names, catalog numbers, and other proprietary references to materials and equipment are made. Such references are made to establish the standards of quality and type required, and not to limit competition. Acceptable manufacturers of competitive products are listed in applicable sections as 'approved equals". Reasonable requests for substitution or additions to "approved equals" will be considered, but the Construction Manager will be the so /e judge of acceptability of items proposed as substitutes. B. Materials and equipment used in carrying out these specifications shall bear U.L. or other recognized testing laboratory label when such labels are avai lab le. PART 3 - EXECUTION 3.1 LOCATIONS A. Mechanical layouts indicated on drawings are diagrammatic. Exact locations of ducts, pipes, and equipment may vary because of conflicts with work of other trades. Work out conf /icts where relocations will not affect operation or appearance of systems. 8. Locate equipment requiring periodic servicing so that it is readily accessib /e. Do not bock up service sides to walls, nor place it too close to other equipment to make service impractical. Equipment service clearances shall meet minimum acceptable distances as recommended by equipment manufacturer. 3.2 UTIL I TIES EXCAVATING AND BACKFILL ING A. Perform trenching, excavating, backfilling for mechanical work in accordance with Section 02300 and as set forth below: 7. Perform work necessary for installation of mechanical /plumbing utilities_ 2. Depth of excavation to provide a minimum of 3' above top of pipe. Excavation to be carried to a depth of at least 6" be /ow bottom of pipe elevation. Fill below pipe (6'), around pipe, and a minimum of 72" above pipe with sand or Class B" crushed stone tamped firm and even. Separate topsoil during excavation. Final layer of dirt (12" minimum) to be topsoil. Trenches to be at /east 18" wider than pipe with batterboards p /aced every 25'. BackfiIling shall be done to exclude use of rock or stone above sand or crushed stone. 3.3 CUTTING AND PATCHING A. Repair or rep /ace routine damage caused by cutting in performance of contract. B. Correct unnecessary damage caused due to installation of mechanical work. C. Perform repairs with materials which match existing and install in accordance with the appropriate section of these specifications. 3.4 CONNECTION OF EQUIPMENT A. Connect or install equipment shown on mechanical drawings that requires plumbing and /or mechanical hookups. 1. Rough --in piping and connect equipment. 2. Provide piping, shutoff valves, and unions required for a complete installation. 3.5 SERVICE OF SYSTEMS A. If equipment is placed in service prior to acceptance of the project by Construction Manager, operate equipment strict /y in accordance with manufacturer's instructions. B. Employ competent, qualified personnel in operation of the equipment. C. Provide for proper operation and cleanliness. D. Open up equipment for inspection as directed by the Construction Manager. E. Lubricate equipment and perform such other maintenance as required by placing it in first class operating condit END OF SECTION PART 1 - GENERAL 1.1 SCOPE OF WORK A. Furnishing of all labor, materials, tools, transportation, services, and related items necessary to complete the installation of the plumbing system as illustrated on the drawings and as including but not limited to the following: 7. Hot and co /d water systems with complete connections from the water meter to all p /umbing fixtures and equipment requiring water connections. 2. Soil, waste, vent and condensate system lines inside and outside the building. 3. Plumbing fixtures, including all the required trim and supports. 4. Trenching and backfiIling. 5. Rough -in and final connection to equipment in the kitchen and service area. 6. Final plumbing connections to heating and air conditioning equipment. 7. Meters and utility connections. 8. Gas piping to heating, ventilating and air conditioning units, water heaters and ovens. PART 2 - PRODUCTS 2.7 DESCRIPTION A. Soil, Waste, and Vent Piping Below Floor to 5' -O" Outside Building: Standard weight coated cast iron pipe and cast iron /neoprene gasket fittings. ABS or PVC-DWV Schedule 40 pipe and fittings may be installed, as approved by local authority in concealed locations on /y. B. Soi /, Waste, and Vent Piping Above Floor: Standard weight coated cast iron pipe and stain less steel /neoprene gasket fitting, or ABS or PVC-DWV Schedu /e 40, as approved by local authority in concealed locations. C. Hot and Cold Water Piping Above the Floor: Type "L" D. Condensate Drain Piping: Type "Al" copper with 50/50 sweat solder and wrought copper fittings or PVC Schedule 40, as approved by local authority. E. Indirect Waste Piping: Type "M" copper with 50/50 sweat so /der and wrought copper fittings or PVC Schedule 40, as approved by local authority. F. Traps and Vents for Service Sinks: ABS or PVC Schedule 40, as approved by /oca/ authority. 2.2 INSULATION SECTION 15400 PLUMBING A. Provide foam rubber insulation equal to Armstrong Armaf lex Type "AP" on co /d and hot water, and condensate drain piping. Insulation to be slipped on with butt joints. Use miter cut pieces for fittings and performed fittings for all valves. App /y manufacturer's paint to all exposed runs. Utilize 7" thick insulation on hot water piping and 1/2" thick on cold water and condensate drain piping. B. Insu /ate 'P" trap and exposed hot water supp /y lines below handicapped accessible hand sinks and lavatories in one of the fo /lowing manners: 7. Molded flexible vinyl insulation system, Model #101 "Nandi Lav- Guard" as manufactured by Truebro. 2. PVC 2 piece "P" trap cover with insulation tubing, "Trap- Guard" as manufactured by Buckaroos. 3. Other manufacturers /types by prior approval only. PLUMBING SPECIFICATIONS SCALE N.T.S. C. PVC PLASTIC 1. Manufacturers: Knauf Fiber Glass: www.knauffiberg/ass.com. Johns Many Ile Corporation: www. jm. com Owens Corning Corp: www.owenscorning.com Certain Teed Corporation: www.certainteed.com Substitutions: The products of other manufacturers may be submitted at the Contractors option, during shop drawing review. The products of other manufacturers .shall meet or exceed al/ requirements of these specifications and all requirements of the project as listed or shown on the drawings. The contractor accepts all resposibi/ity for costs and coordination issues arising out of the substitution of materials or equipment and the coordination of such substitutions with all other contractors and subcontractors. D. Jacket: One piece molded type fitting covers and sheet material, off white color. 1. Minimum Service Temperature: 0 degrees F( -18 degrees C) 2. Maximum Service Temperature: 150 degrees F (66 degrees C). 3. Moisture Vapor Permeability. 0.002 perm inch (0.00029 ng /Pa s sq m) maximum, when tested in accordance with ASTM E 96. 4. Thickness: 10 mi /(.25 mm). 5. Connections: Brush an welding adhesive. E. Covering Adhesive Mastic: Compatible with insulation. 2.3 FIXTURES A. Al/ fixtures: As indicated on drawings with equal products furnished by American Standard, Kohler, or E/jer. 2.4 CLEANOUTS, FLOOR DRAINS, FLOOR SINKS, AND ROOF DRAINS A. A/1 Accessories: As indicated on drawings with equal products furnished by Wade, Josam, or Zurn being acceptab le. 2.5 EQUIPMENT C. Shutoff valves underneath lavatories, tank type water c /osets, and kitchen fixtures: Chrome plated ang /e stop valves with chrome plated escutcheon plates and as scheduled on drawings. D. Hose Bibbs: As scheduled on drawings. E. Vacuum Breakers: As scheduled on drawings. F. Backf/ow preventers: As scheduled on drawings. G. Gas Cocks: Plug valve iron body, bronze tapered plug, lubricated, threaded ends. Rated for 200 CWP, AGA and U.L. listed. PART 3 - INSTALLATION 3.7 PIPING A. Run all piping concealed except where otherwise indicated on drawings. B. Install valves, traps, clean -outs and other apparatus in an easily accessib /e location. C. Install soil, waste, vent offsets, and condensate drains with a minimum uniform grade of one quarter inch to the foot. D. Maintain hot and co /d water lines at /east 6 inches apart where piping in parallel. E. Provide escutcheon plates where all pipes pass through a finished wall. 3.2 HANGERS AND SUPPORTS A. Support copper piping at intervals not to exceed seven feet zero inches and at each change in horizontal or vertical direction. 3.3 PLUMBING FIXTURES A. Furnish and instal/ all p /umbing fixtures complete with all equipment fittings, trimmings, and accessories. B. All Fixtures: Grade A, white. C. Exposed Piping to Fixtures: A product of the fixture manufacturer. D. Provide stops as manufactured by the fixture manufacturer, with metal-to-metal seat for all fixtures and equipment. 3.4 TEST A. The plumbing system and associated system is subject to final approval of the Owner's Representative and Code Authorities having jurisdiction. Perform al/ tests required to show code compliance as directed. 3.5 CLEANING AND PROTECTION A. After the plumbing piping has been installed, inspected, and approved, flush the piping system to remove any foreign matter from the pipes. Where required, use chlorine or HTH solution to sanitize the new piping. END OF SECTION E 5: .. CODE COMPLIANCE APPRCNED mAR 2 () 2006 city Of TukW - B 'LEM alYISION ~ RECEIVED CITY OF TllK1 ALA MAR 13 2008 PERMIT CENTER M O D U S v www.modusystudio.Com S T U D I O ARCHITECT 9260 Modus V Studio 2414 1st Avenue, Unit 705 Seattle, WA 98121 David Tzu -Hsiu Huang 206 -713 -1823 Client Name Project Address SUSHI ITTO 2600 SOUTHCENTER MALL FC13 TUKWILA, WA 98188 REGtsrERF ARC ENGINEERS Schnackel NewYork ❑ Omaha o LasMgeles ❑ 800- 581-0963 www.schnackeLcom EXPIRES 12/21/09 OWNER SUSHI ITTO, SUSHI PACIFIC SUPPLIERS INC. ALBERTO ROMANO 4930 ZAMBRANO ST, CITY OF COMMERCE, CA, 90040 TEL: (323) 278 -9202 FAX: (323) 278 -9212 PERMIT SET SUBMITTAL No. Description Date