Loading...
HomeMy WebLinkAboutPermit PG08-083 - WESTFIELD SOUTHCENTER MALL - LEARNING QUEST TOYSLEARNING QUEST TOYS 2426 SOUTHCENTER MALL PGO8-083 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: City41111f Tukwila 6364200010 2426 SOUTHCENTER MALL TUKW LEARNING QUEST TOYS 2426 SOUTHCENTER MALL , TUKWILA WA WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD CA KEITH SMITH 1725 WESTLAKE AV N, STE 210 , SEATTLE WA Contractor: Name: AMERICAN MECHANICAL CORP Address: PO BOX 1136 , MONROE WA Contractor License No: AMERIMC071BH DESCRIPTION OF WORK: PROVIDE NEW TOILETS Value of Plumbing /Gas Piping: Fees Collected: $25,000.00 $322.00 Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet doc: UPC -10/06 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PLUMBING /GAS PIPING PERMIT Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 FIXTURE TYPE AND QUANTITY Plumbing (cont.) 0 Building sewer and each trailer park sewer 0 O Rain water system - per drain (inside bldg) 0 0 Water heater and /or vent 1 0 Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 0 grease interceptors 0 0 Repair or alteration of water piping and/or water 2 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 2 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 0 0 Medical gas piping (6 +) inlets /outlets 0 O Gas Piping O Gas piping outlets (0 -5) 0 2 Gas piping outlets (6 +) 0 * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 713 -4076 Phone: (206)467 -6407 Expiration Date: 01/08/2009 PG08 -083 06/11/2008 12/15/2008 PG08 -083 Printed: 07 -21 -2008 Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this pe construction or Signature: Print Name: doc: UPC -10/06 City RTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: PG08 - 083 Issue Date: 06/11/2008 Permit Expires On: 12/15/2008 Date: 1 U does not pres e to give authority to violate or cancel the provisions of any other state or local laws regulating wo ' I am authorized to sign and obtain this plumbing /gas piping permit. Date?/ This permit shall become null and void if the worl(is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PG08 -083 Printed: 07 -21 -2008 Parcel No.: Address: Suite No: Tenant: Name: WESTFIELD - VANILLA BOX Address: 2426 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: Address: Contractor: Name: AMERICAN MECHANICAL CORP Address: PO BOX 1136 , MONROE WA Contractor License No: AMERIMC071BH DESCRIPTION OF WORK: PROVIDE NEW TOILETS Value of Plumbing /Gas Piping: Fees Collected: doc: UPC -10/06 Cityillbf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 6364200010 2426 SOUTHCENTER MALL TUKW KEITH SMITH 1725 WESTLAKE AV N, STE 210 , SEATTLE WA $25,000.00 $202.00 Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet PLUMBING /GAS PIPING PERMIT FIXTURE TYPE AND QUANTITY * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 713 -4076 Phone: (206)467 -6407 Expiration Date: 01/08/2009 PG08 -083 06/11/2008 12/08/2008 Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 Plumbing (cont.) 0 Building sewer and each trailer park sewer 0 0 Rain water system - per drain (inside bldg) 0 0 Water heater and/or vent 1 0 Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 0 grease interceptors 0 0 Repair or alteration of water piping and/or water 2 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 2 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 0 0 Medical gas piping (6 +) inlets /outlets 0 0 Gas Piping 0 Gas piping outlets (0 -5) 0 2 Gas piping outlets (6 +) 0 PGO8 -083 Printed: 06 -11 -2008 Permit Center Authorized Signature: Signature: Print Name: doc: UPC -10/06 �UL�v /Q p City (t Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: htip://www.ci.tukwilawa.us Permit Number: PG08 -083 Issue Date: 06/11/2008 Permit Expires On: 12/08/2008 Date: (v l V4, 01) I hereby certify that I have read and e u4ted this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied th whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or tly erf orm ce of work. I am authorized to sign and obtain this plumbing /gas piping permit. Date: 6 // This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PG08 -083 Printed: 06-11 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: 2426 SOUTHCENTER MALL TUKW LEARNING QUEST TOYS 1: ** *PLUMBING AND GAS PIPING * ** • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: PG08 -083 ISSUED 03/17/2008 06/11/2008 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. doc: Cond -10/06 * * continued on next page ** PG08 -083 Printed: 07 -21 -2008 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doc: Cond -10/06 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Date: 7 / 2 ,A PG08 -083 Printed: 07 -21 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 2426 SOUTHCENTER MALL TUKW WESTFIELD - VANILLA BOX 1: ** *PLUMBING AND GAS PIPING * ** PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: PG08 -083 ISSUED 03/17/2008 06/11/2008 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. doc: Cond - 10/06 * *continued on next page ** PG08 -083 Printed: 06 -11 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: A2o,d /JU Iri A4o� doc: Cond -10/06 PG08 -083 Date: - //-6 ordinances governing or local laws regulating Printed: 06-11 -2008 CITY OF ,TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.citukwila.wa.us �j� / King Co Assessor's Tax No.: f -'12e) - -1.rc) ! b ALA t (.e�r Site Address: _ �U.' ) _ V Ad Tenant Name: I . / i t 1r�J ,�ww Property Owners Name: ilf ff/i%I/'L1/I/ - ff Mailing Address: - Afiff r rI �� � X l / � 11i / ad Company Name: Company Name: Mailing Address: Contact Person: E -Mail Address: :ER - Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** ev contac w n you permit s readyyto Suite Number: 7r5CC5 Floor: New Tenant: .Yes City Sta Zip Name: ; ` 1 f ,/�� Day TTelephone: � Mailing Address: 1 1 .2/1:- t 61/LC " '` 1(/C / 7A /G r (4/;11f3— ; rea ) E -Mail Address: / 4 in 1 � (9 So,L COI 61.0° Fax Number: ` 9 0 4 7�t � J Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip la / City Day Telephone: Fax Number: 90 6 46 4-0. (Jv s�7 ) I 4 Z '1 p mu e wet stamped by Engineer, ofRecord intiMAI Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: _ Fax Number: Q:WpplicetionsTorms. Applications On Linen -2006 - Pemrit Application.doc Revised 9 -2006 bh Page 1 of 6 w t LDNG PERMIT INFOR{MATION` e206 431= x6; 0 ° g � tt �w.J.' ar. yl � .' of ... �„n ....' �4ef ' (WRl> e a 1 .�i - !t' an V l! (J Existing Building Valuation: $ Al Scope ork (please provide detailed information): T.r /447 M4,1 /vi ?G r c ref t i( 9 eV., p/v' Z Cm-'i A )//' d tti Ub bi ql e Valuation of Project (contractor's bid price): $ Will there be new rack storage? ❑ Yes If yes, a separate pe ' d plan submittal will be required. `,1 Floor:.` Fl Basement . Accessory Structure', ` Garage .Detached Garage Attached.Carpoit .; Detached Carp!) • ovide All Building Areas in Square Foo e Below . • Covered Uncoveredleck- rI -a PLANNING D ' ' SION; Existing Interior Remodel: ."Addi • : to t' ting cture' ,Type of :. Construction per IBC ,.. - Type of Occupancy, per IBC.,',. 3 Single family buiding footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) 'For an Accessory dwelling, provide the following: Lot Area (sq ft): 'Provide docum • Q:Upplications\Fem s- Applications On linen -2006 - Permit Application.doc Revised 9-2006 bh Floor area of principal dwelling: Floor area of accessory dwelling: Lion that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: & /f'l Compact: Handicap: Will there be a change in use? ❑ Yes t ❑ No If `yes ", explain: FIRE PROTECTION/HAZA OUS MATERIALS: [)Y Sprinklers Automatic Fire Alarm None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes Eg/ No If 'yes , attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 Fixture TYPe �� 'Qty' Fixture T YPe IL 4e, :6 Ofixture Type: Qty FSxture i £ i s wQty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain , Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain 2 Sinks Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory ,� Water Closet n - !/ Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent � Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: /✓ City Contact Person: Day Telephone: E -Mail Address Fax Number:__ Contractor Registration Number: Expiration Date: Valuation of Plumbing work (contractor's bid price): $ re" Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): pr6V/ 6 nett/ L 7-e fy Q:1 Applications\Fmms- Applieetions On Line'3 -2106 - Permit Application.doc Revised 9 -2006 bh Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: State Zip Sewer: Page 5 of 6 I Date Application Accepted: Date Application Expires: r Staff Initials: vD ��) ` ��� I /l1 I Signature: PERNII.T APPLICATION,NOTES = Applicable to all permits inc this ;application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I lIEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 NER OR AUTHORIZED AGENT: Print Name: Mailing Address: W l� Q:1Applicmi Farms- Applieatiom On Lind3-2006 - Permit Applicstion.doc Revised 9.2006 bh Day Telephon 1f _ Mit Ni Siz % City Page 6 of 6 • Parcel No.: Address: Suite No: Applicant: Receipt No.: R08 - 02669 Initials: WER User ID: 1655 Payee: AMC TRANSACTION LIST: Type Method Descriptio (inn: Raraint -O6 Payment Check 19535 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 6364200010 2426 SOUTHCENTER MALL TUKW LEARNING QUEST TOYS RECEIPT Amount ACCOUNT ITEM LIST: Description Account Code 60.00 PLUMBING - NONRES 000.322.103.00.0 Total: $60.00 Permit Number: Status: Applied Date: Issue Date: Payment Amount: Payment Date: Balance: Current Pmts 60.00 $60.00 PG08 -083 ISSUED 03/17/2008 06/11/2008 07/21/2008 02:35 PM $0.00 Printpd: 07-71 -7008 Parcel No.: Address: Suite No: Applicant: Receipt No.: Initials: User ID: Payee: doc: Receipt -06 City �f Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us 6364200010 2426 SOUTHCENTER MALL TUKW WESTFIELD - VANILLA BOX R08 -02234 WER 1655 AMC TRANSACTION LIST: Type Method Descriptio Payment Check 19445 ACCOUNT ITEM LIST: Description Account Code RECEIPT Amount 60.00 PLUMBING - NONRES 000.322.103.00.0 Permit Number: Status: Applied Date: Issue Date: Payment Amount: Payment Date: Balance: Current Pmts 60.00 Total: $60.00 $60.00 4050 06/24 9710 TOTAL PG08 -083 ISSUED 03/17/2008 06/11/2008 06/23/2008 03:05 PM $0.00 360.00 Printed: 06 -23 -2008 RECEIPT NO: RO8 -02070 Initials: JEM User ID: 1165 Payee: AMC SET TRANSACTIONS: Set Member Amount ACCOUNT ITEM LIST: Description City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: //www. ci. tukwila. wa. us ugan 83 164.00 PG08 -085 164.00 PG08 -086 188.00 PG08 -104 164.00 PG08 -10.5 164.00 PG08 -128 512.00 PG08 -129 512.00 PG08 -130 512.00 PGO8 -131 512.00 PGO8 -132 512.00 TOTAL: 3,404.00 PLAN CHECK - NONRES PLUMBING - NONRES SET RECEIPT Payment Date: 06/11/2008 Total Payment: 3,404.00 SET ID: 0611 SET NAME: WESTFIELD PLUMBING TRANSACTION LIST: Type Method Description Amount Payment Check 19416 3,404.00 TOTAL: 3,404.00 Account Code Current Pmts 000/345.830 1,800.00 000.322.103.00.0 1,604.00 TOTAL: 3,404.00 3538 06/11 9711 TOTAL 3404°00 r, -... o rre rmc no RECEIPT NO: R08 -00793 Initials: JEM User ID: 1165 Payee: ERIK S BARTH SET TRANSACTIONS: Set Member Amount D08 -142 862.94 EL08 -260 123.00 � -081 101.50 ., . 083 38.00 TOTAL: 1,125.44 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http. //www.ci.tukwila.wa.us SET ID: S000000982 SET NAME: Tmp set/Initialized Activities TRANSACTION LIST: Type Method Description Amount Payment Check 217 ACCOUNT ITEM LIST: Description ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES SET RECEIPT TOTAL: • Payment Date: 03/17/2008 Total Payment: 1,125.44 1,125.44 1,125.44 Account Code Current Pmts 000.345.832.00.0 123.00 000/345.830 1,002.44 TOTAL: 1,125.44 Project: L eAR6u►N6:. Type of Inspection: i tNA k-- PI (Q. ill k) Address: 0,14Z7_ MAO Date Called: Special Instructions: Date Wanted: --- 2 3 -- m. Requester: Phone No: _ - 206. -- ^�/ r � z INSPECTION RECORD Retain a copy with permit U (- - U PERMIT NO. CITY OF TUKWILA BUILDING DIVISION f 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367 INSPECTION NO. COMMENTS: /C4/7 ed eorktp/e7 Approved per applicable codes. El Corrections required prior to approval. ri $60 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be pai at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: n Date: Receipt No.: Date: COMMENTS: l 7 DL Address: Date Called: V 0 : ?1r NT t 4>d.rA3-Q_ Qa2 Dere- 0L - v 'LJ & Phone No: ,-66 - 02 -7 /vz J CAF �. .. ;• g -0 -60...„) .„1,, 6 , 0 tc - isiorirt ork,ii.-- i oce.„ % r,“."tok 1 I 1 Project: / J 04- t Type I I ns ly -. n! �, A/ 17 l Address: Date Called: Special Instructions: Date Wanted: 60 --/ '. Q62 a.m p.m. Requester: Phone No: ,-66 - 02 -7 /vz J 1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. ' CITY OF TUKWILA BUILDING DIVISION - 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 g Approved per applicable codes. 0 Corrections required prior to approval. Inspector: Date: o$ ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: aT� u" v�`�a:�. ACTIVITY NUMBER: PG08 -083 DATE: 07 -11 -08 PROJECT NAME: LEARNING QUEST TOYS SITE ADDRESS: 2426 SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 2 After Permit Issued DEPARTMENTS: M 1-1 Buildin Division Public W rks � (�. �4`S - 045 Complete TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 ° PERMIT COORD P CO Y PLAN REVIEW /ROUTING SLIP Approved with Conditions Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete Structural Review Required n DATE: DATE: Planning Division Permit Coordinator DUE DATE: 07 -15 -08 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ❑ No further Review Required DUE DATE: 08-12 -08 Not Approved (attach comments) n Permit Center Use Only • CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: PG08 -083 DATE: 06 -16 -08 PROJECT NAME: WESTFIELD VANILLA BOX SITE ADDRESS: 2426 SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 after Permit Issued DEPARTMENTS: B iii g 'vision Public Works nitt DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved 17f Approved with Conditions Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 � i'�RMIT COORD COPYf PLAN REVIEW /ROUTING SLIP Fire Prevention n Planning Division n Structural Incomplete n DATE: Permit Coordinator DUE DATE: 06-17-08 Not Applicable n No further Review Required DUE DATE: 07-15-08 Not Approved (attach comments) DATE: n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: PG08 - 083 PROJECT NAME: WESTFIELD VACANT SPACE SITE ADDRESS: 2426 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # DATE: 03 -17 -08 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: kivt9 Bu11di ig D sion Public Works HERMIT COORD COPY � PLAN REVIEW /ROUTING SLIP Comments: Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete IA Incomplete Planning Division Permit Coordinator DUE DATE: 03-20-08 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ LETTER OF COMPLETENESS MAILED: Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 d Structural Review Required Approved with Conditions No further Review Required DATE: DUE DATE: 04-17-08 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITI S 2 7 - 11-06 i - fit -OK Ute Summary of Revision: - te1,6110N of 121t/C 'novvA '. vl frn. - wfizgv h l fr&pkw.- Kv r ) Received by: J 7 ,�� REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 2 7 - 11-06 i - fit -OK Ute Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 2 7 - 11-06 i - fit -OK Ute Summary of Revision: Cl v ve 3-o TT Received by: y: ,o,��r� L �.,..._ REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: PROJECT NAME: SITE ADDRESS: if I Lid A REVISION LOG PERMIT NO: P(5b51f0 ORIGINAL ISSUE DATE: alt jL j 1? (please print) (please print) (please print) (please print) (please nrintl • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila Washington 98188 Phone: 206- 431 -3670 Fax: 206- 431 -3665 Web site: http: / /www.c'i.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 7A/ /D Plan Check/Permit Number: ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # Revision # 2- after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ■applicationslforms= applications on line revis96a "submittal Created: 8 -13 -2004 e.: 4 ' s T y5 04-4-y 4e.-Q : J 41 • .r. Thee/Got SA t Pay _- OiP3 Steven M. Mullet, Mayor Steve Lancaster, Director Project Name: Leay-,7; () 4 esi- TES l- 'Iri �er4 ec,le,,s/- ,..k vgHi 114 & Project Address: Z ce- 1 4 e -s, 7 A � S o�,� - � �lI Contact Person: Q 4.- e—t'et- PL/v Phone Number: e/ s" -1-7 a-- 8,2..3 Summary of Revision: 6/74 nn e V441; /14 Be x (S4 /es r 3/ S/ 218 RECSVED f Tu}yiA JUL 11 1006 Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on _ _ I I Q r C=ENTER Date: ❑ El Sheet Number(s): P City of Tukwila Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. ❑ Response to Incomplete Letter Response to Correction Letter # Revision # f after Permit is Issued Revision "requested by a City Building Inspector �r Plans Examiner Project Name : 1A) e RT' rg i e;t (/ G zit � ' // el? r�c7 y Project Address : 2 Contact Person: Q,—,' a Pd�df'em= , Phone Number: C X 842 —6671 Summary of Revision: Re-e-) i 51 5 (a u d e- PI u G i ' t v / lam„ i- - ; 5 e--e_ v Yea. c / /Y - d e fe.r4 0�, _ a m 7 i 4 roc. _J-� -_ l'Oa,5 _ i-'I s e_."- - � « =r- ,, q 4-7-- 0 5 d%4 ;1 )-e4 > S a 7 re /24,- c% /e.Ae o f 0, 7‘; 1 ' "Cloud" or highlight all areas of revision including date o Received at the City of Tukwila Permit Center by Entered in Permits Plus on 0(D(RfI kapplications\fomu- applications on line revision submittal Created: 8 -13 -2004 Department of Community Development 6300 Southcenter Boulevard Suite #i 00 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206- 431 -3665 Web site: http : //www.ci.tukwila.wa.us Plan Check/Permit Number: P6 Off - Og3 revision Steven M. Mullet, Mayor Steve Lancaster, Director RECEIVED CITY OF TUKWIfA 1 JUN 16 2008 rtrtlwi I k•tM l kh License Information License AMERIMC071BH Licensee Name AMERICAN MECHANICAL CORP Licensee Type CONSTRUCTION CONTRACTOR UBI 601433818 Ind. Ins. Account Id 53821001 Business Type CORPORATION Address 1 PO BOX 1136 Address 2 City MONROE County SNOHOMISH State WA Zip 982724136 Phone 2064676407 Status ACTIVE Specialty 1 BOILER/STEAM FIT/PROC PIPING Specialty 2 PLUMBING Effective Date 1/8/1993 Expiration Date 1/8/2009 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date KING, CHERI L PRESIDENT 01/08/1993 KING, KELLY E TREASURER 01/08/1993 Look Up a Contractor, Electra aan or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date OLD REPUBLIC SURETY Until • Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= AMERIMC071BH 06/11/2008 PLU v1BING FIXTURE SCHEDULE PLAN MARK MANUFACTURER MODEL NUMBER NOTES WC AMERICAN STANDARD #2168.100 C/W SUPPLY PIPING, ANGLE VALVE, WALL FLANGE AND FLEXIBLE RISER. (ZURN ZH- 8825— CR —LK) SEAT OLSONITE #46SSTL LAV ADVANCE 7 —PS -50 STAINLESS STEEL SINK, LEVER OPERATED DRAIN K -26, S.S. BASKET K -6, ADVANCE FAUCET K -9, WH A.O. SMITH ELJF -10 1.0 —G.A. STORAGE CAPACITY, 3.0 INPUT, 208V. ELECTRIC WATER HEATER FD ZURN ZN-- 415 --6S CAST WITH DEEP SEAL TRAP AND 6" STRAINER TP PPP INC. #PR -500 FULLY AUTOMATIC, ALL BRASS TRAP PRIMER VALVE, ACTIVATED BY A DROP IN BUILDING WATER PRESSURE, NO AJUSTMENT REQUIRED, MODEL PRIME —RITE FOR 1 TO 4 TRAPS WITH DISTRIBUTION UNIT. MUST BE INSTALLED ON A FRESH COLD WATER LINE OF 1 1/2" DIAMETER OR LESS, AS INDICATED ON DRAWINGS, OR REQUIRED BY PLUMBING CODE. WCO ZURN -- WALL CLEAN OUT —CAST IRON CLEAN OUT TEE WITH BRONZE THREADED CLEAN OUT PLUG. PLUG TO BE GAS AND WATER TIGHT. WALL ACCESS PANEL — ZURN #ZANB- 1460 -9 9 "x9" WALL ACCESS PANEL AND FRAME: SMOOTH NICKEL BRONZE SECURING LUGS. GENERAL PLUvIBI\ G OTES 1. ALL PLUMBING INSTALLATIONS SHALL COMPLY WITH STATE AND LOCAL CODES. 2. PLUMBING CONTRACTOR SHALL MAKE CORRECTIONS IF WATER SUPPLY AND DRAINAGE FOR THE BUILDING ARE REVERSED. 3. INSTALL ALL THREADED CLEANOUT PLUGS WITH PIPE DOPE TO ALLOW EASY REMOVAL IN THE FUTURE. 4. IT WILL BE THE RESPONSIBIUTY OF THE PLUMBING CONTRACTOR TO INSURE THAT ITEMS TO BE FURNISHED UNDER PLUMBING CONTRACT WILL FIT THE SPACE AVAILABLE — PLUMBING CONTRACTOR SHALL MAKE NECESSARY FIELD MEASUREMENTS TO ASCERTAIN SPACE REQUIREMENTS, INCLUDING THOSE FOR CONNECTIONS AND SHALL FURNISH AND INSTALL SUCH SIZES AND SHAPES OF EQUIPMENT THAT ARE THE TRUE INTENT OF THE DRAWINGS AND SPECIFICATIONS. 5, GENERAL CONTRACTOR SHALL PROVIDE ALL OPENINGS IN WALLS, FLOORS, AND ROOF WITH EACH CONTRACTOR RESPONSIBLE FOR VERIFYING LOCATION AND SIZES OF ALL OPENINGS REQUIRED UNDER HIS CONTRACT, UNLESS NOTED OTHERWISE ON THE PLANS. 6. PLUMBING CONTRACTOR SHALL PROVIDE PRESSURE REDUCING VALVE, SWEAT TYPE, 30 -60 P51G DISCHARGE RANGE WHERE REQUIRED BY LOCAL CODES. 7, ALL PLUMBING FIXTURES SHALL BE NEATLY CAULKED WITH SILICONE COMPOUND WHERE FIXTURE MEETS WALL. 8. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ELECTRICAL AND CONTROL CONNECTIONS TO PLUMBING EQUIPMENT WITH THE ELECTRICAL CONTRACTOR. SEE PLANS FOR LOCATIONS OF JUNCTION BOXES, DISCONNECTS, AND CIRCUIT BREAKERS (PANEL BOARDS). TYPE, SIZE AND NUMBER OF CONDUCTORS AND CONDUITS TO EQUIPMENT SHALL BE COORDINATED WITH Sc VERIFIED BY THE ELECTRICAL CONTRACTOR. IN CASE OF PLUMBING EQUIPMENT CONNECTION TO A CIRCUIT BREAKER, THE NUMBER AND SIZE OF CONDUCTORS AND CONDUIT SHALL CONFORM TO THE LATEST NATIONAL ELECTRICAL CODE REGULATIONS. ALL MOTOR STARTERS, SWITCHES, CONTROL DEVICES, ETC., PROVIDED BY THIS CONTRACTOR SHALL BE RECESSED IN THE WALLS, EXCEPT WHERE THESE ITEMS ARE LOCATED IN MECHANICAL ROOMS. PROVIDE NAMEPLATES FOR ALL EQUIPMENT, SWITCHES, CONTROL DEVICES, ETC. 9. PLUMBING CONTRACTOR SHALL SUPPLY AND INSTALL GAS PIPING IF SHOWN ON PLANS. ALL GAS PIPING SHALL COMPLY WITH LOCAL CODES. PLUMBING CONTRACTOR SHALL MAKE FINAL CONNECTIONS TO ALL EQUIPMENT. INSTALL REGULATORS AT EQUIPMENT WHERE REQUIRED BY MANUFACTURER OR CUTS SUPPLIED BY FURNISHING CONTRACTOR. 10. PLUMBING CONTRACTOR SHALL INSTALL SHOCK ABSORBERS AT PLACES INDICATED ON THE PLANS AND RISER DIAGRAM. SHOCK ABSORBERS SHALL BE PDI APPROVED. 11. ALL UNDERGROUND DRAINAGE, WASTE AND VENT PIPE SHALL BE CAST IRON OR PVC AS ALLOWED BY LOCAL CODES. ALL ABOVE GROUND DRAINAGE, WASTE AND VENT PIPE SHALL BE PVC. 12. CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR APPROVED FLOOR PLAN AND DIMENSIONS. DO NOT SCALE PLUMBING DRAWINGS. 13. CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING CONDENSATE DRAIN PIPING ON AIR HANDLING UNITS. COORDINATE WORK WITH MECHANICAL CONTRACTOR. 14. CONTRACTOR SHALL INSTALL WATER PIPING SD THAT PIPE JOINTS ARE NOT UNDER FLOOR SLAB. 15. PIPE INSULATION SHALL BE CONTINUOUS THROUGH WALLS OR FLOOR. 16. CONTRACTOR SHALL TEST SOIL, WASTE AND VENT SYSTEMS WITH PEPPERMINT. ALL MECHANICAL SYSTEMS SHALL BE RUNNING WHILE THESE TESTS ARE BEING MADE. CONTRACTOR SHALL FURNISH A CERTIFICATE OF COMPLIANCE AND ACCEPTANCE OF THESE TESTS. 17. CONTRACTOR SHALL INSULATE ALL UNDER SLAB HOT WATER PIPING WITH 1" RIGID URETHANE FOAM INSULATION AND 1" CLOSED CELL RUBBER INSULATION, WITH FIRE RETARDANT COATING ON ALL HOT WATER AND RETURNS LINES ABOVE SLAB. INSULATE ALL COLD WATER LINES ABOVE SLAB WITH 1/2" CLOSED CELL RUBBER FIRE RETARDANT INSULATION. 18. ANY DEVIATIONS FROM SPECIFIED PLUMBING FIXTURES AND TRIM IN FIXTURE SCHEDULE SHALL BE APPROVED PRIOR TO SUBMITTAL FROM THE ALDO'S PROJECT MANAGER. 19. ALL INDIRECT WASTE LINES SHALL HAVE A MINIMUM OF 2" VERTICAL AIR GAP AT FLOOR SINK, DRAIN OR HUB. FLOOR SINKS, DRAINS OR HUBS SHALL EXTEND A MINIMUM 1" ABOVE FINISHED FLOOR WHEN SERVING INDIRECT DRAINS. 20. VACUUM BREAKERS SHALL BE INSTALLED ON ALL HOSE BIBBS AND HYDRANTS. VACUUM BREAKERS /BACK FLOW PREVENTORS TO BE INSTALLED AT ANY POINT WHERE THERE IS DANGER OF THE NON POTABLE WATER SYSTEM COMING IN CONTACT WITH THE PORTABLE WATER SYSTEM OR ANY DANGER OF BACK FLOW. COORDINATE WITH LOCAL INSPECTOR. 21. ALL PLUMBING WORK SHALL BE COORDINATED WITH OTHER PROJECT CONTRACTORS BEFORE INSTALLATION. 22. USE TYPE "K" SOFT DRAWN COPPER UNDER SLAB. 23. ALL WATER DISTRIBUTION PIPE ABOVE GROUND SHALL BE COPPER OR COPPER ALLOY TUBING. VACUUM RELIEF VAVLE (VALVE AND TEE ABOVE WATER HEATER) TACO CX -15 EXPANSION TANK, FDA AND ASME APPROVED FOR POTABLE WATER. • .1" WATER RISER DIAGRAM 2 I PROVIDE BALL VALVE. UNION 10 GALLON WATER HEATER ABOVE TOILET CEILING. PROVIDE .3" DEEP GALV PAN W /SOLDERED SEAMS. TERMINATE INDIRECTLY INTO FLOOR DRAIN ROUTE AUX. DRAIN TO APPROVED RECEPTOR SUCH AS TATTLETAIL DRAIN ETC. WATER HEATER T & P AND DRAIN PAN CANNOT CAUSE TRIPPING HAZARD. VERIFY EXACT LOCATION IN FIELD. TO TRAP PRIMER CONNECTION AT FD LAV cs-o4t. l EXTEND NEW 4" SS TO EXISTING SYSTEM, VERIFY EXACT LOCATION, FLOW AND DEPTH. EXTEND NEW 4" SS TO EXISTING SYSTEM, VERIFY EXACT LOCATION, FLOW AND DEPTH. 3" N I i N WC r PLUMBING PLAN 3" FD W /TRAP PRIMER PROVIDE AND INSTALL 4" V.T.R. i ED O LAV WC ( if- _- .............:............1£. . WASTE RISER DIAGRAM 101 I o = .. Na change ' of work w thOiJt p rloi cap14Dr�71,"�I O ` Tukwila Building Div NOTE: Revisions will require a neW P!? ►s usand Revisions i! and may include additions! plan re'r'n,�t 1(37 �P�I7`ate a FILE copy Permit No. Yig<0.&012. Ply revit?w approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopt- • * y • - or o • *4. flemVt a; approved C . d , . $. ., �, _ Meted: Data: - oe City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 16 2008 PERMIT CENTER 2426 Southcenter Mall Tukwila, WA 98188 smith cc 318 terry avenue n seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith@smithco.org http: / /www.smithco.org/ Consultant Consultant Registration 1 02.08.08 2 03.26.08 3 04.07.08 4 04.21.08 5 05.30.08 Project Name Issues 6294 WESTFIELD SOUTHCENTER MALL Project Number 02008018.00 Description PLUMBING PLAN Computer File CW05- 2008— P1,DWG Scale AS NOTED Template P -1 Architect Registration By Check PERMIT KLS BLDG. COMMENTS KLS PERMIT CORR. KLS OWNER REVISIONS KLS ISSUE KLS All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. IIc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. IIc. PLUvIBII\C FIXTURE SCHEDULE PLAN MARK MANUFACTURER MODEL NUMBER NOTES WC AMERICAN STANDARD #2168.100 C/W SUPPLY PIPING, ANGLE VALVE, WALL FLANGE AND FLEXIBLE RISER. (ZURN ZH- 8825- CR -LK) SEAT OLSONITE #4655T1 LAV ADVANCE 7 -PS -50 STAINLESS STEEL SINK, LEVER OPERATED DRAIN K -26, S.S. BASKET K -6, ADVANCE FAUCET K-9, WH A.O. SMITH ELJF -10 1.0 --G.A. STORAGE CAPACITY, 3.0 INPUT, 208V. ELECTRIC WATER HEATER FD ZURN ZN- 415 -6S CAST WITH DEEP SEAL TRAP AND 6" STRAINER TP PPP INC. #PR -500 FULLY AUTOMATIC, ALL BRASS TRAP PRIMER VALVE, ACTIVATED BY A DROP IN BUILDING WATER PRESSURE, NO AJUSTMENT REQUIRED, MODEL PRIME -RITE FOR 1 TO 4 TRAPS WITH DISTRIBUTION UNIT. MUST BE INSTALLED ON A FRESH COLD WATER LINE OF 1 1/2" DIAMETER OR LESS, AS INDICATED ON DRAWINGS, OR REQUIRED BY PLUMBING CODE. WCO ZURN __ WALL CLEAN OUT -CAST IRON CLEAN OUT TEE WITH BRONZE THREADED CLEAN OUT PLUG. PLUG TO BE GAS AND WATER TIGHT. WALL ACCESS PANEL - ZURN #ZANB- 1460 -9 9 "x9" WALL ACCESS PANEL AND FRAME: SMOOTH NICKEL BRONZE SECURING LUGS. GENERAL PLU V BING NOTES 1. ALL PLUMBING INSTALLATIONS SHALL COMPLY WITH STATE AND LOCAL CODES. 2. PLUMBING CONTRACTOR SHALL MAKE CORRECTIONS IF WATER SUPPLY AND DRAINAGE FOR THE BUILDING ARE REVERSED. 3. INSTALL ALL THREADED CLEANOUT PLUGS WITH PIPE DOPE TO ALLOW EASY REMOVAL IN THE FUTURE. 4. IT WILL BE THE RESPONSIBILITY OF THE PLUMBING CONTRACTOR TO INSURE THAT ITEMS TO BE FURNISHED UNDER PLUMBING CONTRACT WILL FIT THE SPACE AVAILABLE - PLUMBING CONTRACTOR SHALL MAKE NECESSARY FIELD MEASUREMENTS TO ASCERTAIN SPACE REQUIREMENTS, INCLUDING THOSE FOR CONNECTIONS AND SHALL FURNISH AND INSTALL SUCH SIZES AND SHAPES OF EQUIPMENT THAT ARE THE TRUE INTENT OF THE DRAWINGS AND SPECIFICATIONS. 5. GENERAL CONTRACTOR SHALL PROVIDE ALL OPENINGS IN WALLS, FLOORS, AND ROOF WITH EACH CONTRACTOR RESPONSIBLE FOR VERIFYING LOCATION AND SIZES OF ALL OPENINGS REQUIRED UNDER HIS CONTRACT, UNLESS NOTED OTHERWISE ON THE PLANS. 6. PLUMBING CONTRACTOR SHALL PROVIDE PRESSURE REDUCING VALVE, SWEAT TYPE, 30 -60 PSIG DISCHARGE RANGE WHERE REQUIRED BY LOCAL CODES. 7. ALL PLUMBING FIXTURES SHALL BE NEATLY CAULKED WITH SILICONE COMPOUND WHERE FIXTURE MEETS WALL. 8. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ELECTRICAL AND CONTROL CONNECTIONS TO PLUMBING EQUIPMENT WITH THE ELECTRICAL CONTRACTOR. SEE PLANS FOR LOCATIONS OF JUNCTION BOXES, DISCONNECTS, AND CIRCUIT BREAKERS (PANEL BOARDS). TYPE, SIZE AND NUMBER OF CONDUCTORS AND CONDUITS TO EQUIPMENT SHALL BE COORDINATED WITH & VERIFIED BY THE ELECTRICAL CONTRACTOR. IN CASE OF PLUMBING EQUIPMENT CONNECTION TO A CIRCUIT BREAKER, THE NUMBER AND SIZE OF CONDUCTORS AND CONDUIT SHALL CONFORM TO THE LATEST NATIONAL ELECTRICAL CODE REGULATIONS. ALL MOTOR STARTERS, SWITCHES, CONTROL DEVICES, ETC., PROVIDED BY THIS CONTRACTOR SHALL BE RECESSED IN THE WALLS, EXCEPT WHERE THESE ITEMS ARE LOCATED IN MECHANICAL ROOMS. PROVIDE NAMEPLATES FOR ALL EQUIPMENT, SWITCHES, CONTROL DEVICES, ETC. 9. PLUMBING CONTRACTOR SHALL SUPPLY AND INSTALL GAS PIPING IF SHOWN ON PLANS. ALL GAS PIPING SHALL COMPLY WITH LOCAL CODES. PLUMBING CONTRACTOR SHALL MAKE FINAL CONNECTIONS TO ALL EQUIPMENT. INSTALL REGULATORS AT EQUIPMENT WHERE REQUIRED BY MANUFACTURER OR CUTS SUPPLIED BY FURNISHING CONTRACTOR. 10. PLUMBING CONTRACTOR SHALL INSTALL SHOCK ABSORBERS AT PLACES INDICATED ON THE PLANS AND RISER DIAGRAM. SHOCK ABSORBERS SHALL BE PD1 APPROVED. 11. ALL UNDERGROUND DRAINAGE, WASTE AND VENT PIPE SHALL BE CAST IRON OR PVC AS ALLOWED BY LOCAL CODES. ALL ABOVE GROUND DRAINAGE, WASTE AND VENT PIPE SHALL BE PVC. 12. CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR APPROVED FLOOR PLAN AND DIMENSIONS. DO NOT SCALE PLUMBING DRAWINGS. 13. CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING CONDENSATE DRAIN PIPING ON AIR HANDLING UNITS. COORDINATE WORK WITH MECHANICAL CONTRACTOR. 14. CONTRACTOR SHALL INSTALL WATER PIPING 50 THAT PIPE JOINTS ARE NOT UNDER FLOOR SLAB. 15. PIPE INSULATION SHALL BE CONTINUOUS THROUGH WALLS OR FLOOR. 16. CONTRACTOR SHALL TEST SOIL, WASTE AND VENT SYSTEMS WITH PEPPERMINT. ALL MECHANICAL SYSTEMS SHALL BE RUNNING WHILE THESE TESTS ARE BEING MADE. CONTRACTOR SHALL FURNISH A CERTIFICATE OF COMPLIANCE AND ACCEPTANCE OF THESE TESTS. 17. CONTRACTOR SHALL INSULATE ALL UNDER SLAB HOT WATER PIPING WITH 1" RIGID URETHANE FOAM INSULATION AND 1" CLOSED CELL RUBBER INSULATION, WTH FIRE RETARDANT COATING ON ALL HOT WATER AND RETURNS UNES ABOVE SLAB. INSULATE ALL COLD WATER LINES ABOVE SLAB WITH 1/2" CLOSED CELL RUBBER FIRE RETARDANT INSULATION. 18. ANY DEVIATIONS FROM SPECIFIED PLUMBING FIXTURES AND TRIM IN FIXTURE SCHEDULE SHALL BE APPROVED PRIOR TO SUBMITTAL FROM THE ALDO'S PROJECT MANAGER. 19. ALL INDIRECT WASTE LINES SHALL HAVE A MINIMUM OF 2" VERTICAL AIR GAP AT FLOOR SINK, DRAIN OR HUB. FLOOR SINKS, DRAINS OR HUBS SHALL EXTEND A MINIMUM 1" ABOVE FINISHED FLOOR WHEN SERVING INDIRECT DRAINS. 2D. VACUUM BREAKERS SHALL BE INSTALLED ON ALL HOSE BIBBS AND HYDRANTS. VACUUM BREAKERS /BACK FLOW PREVENTORS TO BE INSTALLED AT ANY POINT WHERE THERE IS DANGER OF THE NON POTABLE WATER SYSTEM COMING IN CONTACT WITH THE PORTABLE WATER SYSTEM OR ANY DANGER OF BACK FLOW. COORDINATE WTH LOCAL INSPECTOR. 21. ALL PLUMBING WORK SHALL BE COORDINATED WITH OTHER PROJECT CONTRACTORS BEFORE INSTALLATION. 22. USE TYPE "K" SOFT DRAWN COPPER UNDER SLAB. 23. ALL WATER DISTRIBUTION PIPE ABOVE GROUND SHALL BE COPPER OR COPPER ALLOY TUBING. VACUUM RELIEF VAVLE (VALVE AND TEE ABOVE WATER HEATER) TACO CX -15 EXPANSION TANK, FDA AND ASME APPROVED FOR POTABLE WATER. SCALE: N.T.S. WC TO TRAP PRIMER CONNECTION AT FD FD LAV WATER RISER DIAGRAM PROVIDE BALL VALVE. UNION 10 GALLON WATER HEATER ABOVE TOILET CEILING. PROVIDE 3" DEEP GALV PAN W /SOLDERED SEAMS. TERMINATE INDIRECTLY INTO FLOOR DRAIN ROUTE AUX. DRAIN TO APPROVED RECEPTOR SUCH AS TATTLETAIL DRAIN ETC. WATER HEATER T & P AND DRAIN PAN CANNOT CAUSE TRIPPING HAZARD. VERIFY EXACT LOCATION IN FIELD. WC 3 TO TRAP PRIMER CONNECTION AT FD FD LAV EXTEND NEW 4" SS TO EXISTING SYSTEM, VERIFY EXACT LOCATION, FLOW AND DEPTH. r —PROVIDE AND INSTALL JIL V.T.R. 3" FD W /TRAP PRIMER LAV SCALE: N.T.S. EXTEND NEW 4" SS TO EXISTING SYSTEM, VERIFY EXACT LOCATION, FLOW AND DEPTH. 3" FD W /TRAP PRIMER I >I WC LAV WC WASTE RISER DIAGRAM PLUMBING PLAN SCALE: 1 /4" = 1' -0" l BEMs____ No changes shall be made to the scope of work without prior approval of Tukwila Budding Division. �; Revisions wilt require a new plan submittal N and may include additional plan rev1ew fees. FILE OPY Permit No. City of Tukwila BUILDING DIVISION SEPARATE PERMIT REQUIRED FOR: hanical Electrical Plumbing 0 Gas piping City of Tukwila BUILDING DIVISION RECEIVED m� - O ?nns Pu[3L: c 2426 Southcenter Mall Tukwila, WA 98188 smith Co. 318 terry avenue n seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith @smithco.org http: / /www.smithco.org/ Consultant Consultant Registration Issues and Revisions No. Date 1 th 0 Plar review approval is subject to errors and orris. Approval of construtlian documents does not authorize the violation of any adopted code or ordinance. i'Ipt of approved F ; • arpd corms is By Date: 02.08.08 6294 Project Name Project Number 02008018,00 WESTFIELD SOUTHCENTER MALL Description PLUMBING PLAN Computer File CW05- 2008— P1.DWG Scale AS NOTED P -1 REGISTERED ARCH4TECT El I STATE OF WASHINGTON Architect Registration Issues By Check PERMIT KLS RECEIVED CiTY OF TUKWILA MAR 1 1 'LUUU Template 4.3 (120101) PERMIT CENTER All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. IIc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. Ho.