DESCRIPTION OF WORK:
PROVIDE NEW TOILETS
Value of Plumbing /Gas Piping:
Fees Collected:
$25,000.00
$322.00
Plumbing
Bathtub or combination bath/shower
Bidet
Clothes washer, domestic
Dental unit, cuspidor
Dishwasher, domestic, with independent drain
Drinking fountain or water cooler (per head)
Food -waste grinder, commercial
Floor drain
Shower, single head trap
Lavatory
Wash fountain
Receptor, indirect waste
Sinks
Urinals
Water Closet
doc: UPC -10/06
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
PLUMBING /GAS PIPING PERMIT
Uniform Plumbing Code Edition: 2006
International Fuel Gas Code Edition: 2006
FIXTURE TYPE AND QUANTITY
Plumbing (cont.)
0 Building sewer and each trailer park sewer 0
O Rain water system - per drain (inside bldg) 0
0 Water heater and /or vent 1
0 Industrial waste treatment interceptor, including
0 its trap and vent, except for kitchen type
0 grease interceptors 0
0 Repair or alteration of water piping and/or water
2 treatment equipment 0
0 Repair or alteration of drainage or vent piping 0
2 Medical gas piping system serving (1 -5)
0 inlets /outlets for a specific gas 0
0 Medical gas piping (6 +) inlets /outlets 0
O Gas Piping
O Gas piping outlets (0 -5) 0
2 Gas piping outlets (6 +) 0
* *continued on next page **
Permit Number:
Issue Date:
Permit Expires On:
Phone:
Phone: 206 713 -4076
Phone: (206)467 -6407
Expiration Date: 01/08/2009
PG08 -083
06/11/2008
12/15/2008
PG08 -083 Printed: 07 -21 -2008
Permit Center Authorized Signature:
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this pe
construction or
Signature:
Print Name:
doc: UPC -10/06
City RTukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206- 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Permit Number: PG08 - 083
Issue Date: 06/11/2008
Permit Expires On: 12/15/2008
Date: 1 U
does not pres e to give authority to violate or cancel the provisions of any other state or local laws regulating
wo ' I am authorized to sign and obtain this plumbing /gas piping permit.
Date?/
This permit shall become null and void if the worl(is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PG08 -083 Printed: 07 -21 -2008
Parcel No.:
Address:
Suite No:
Tenant:
Name: WESTFIELD - VANILLA BOX
Address: 2426 SOUTHCENTER MALL , TUKWILA WA
Owner:
Name: WESTFIELD PROPERTY TAX DEPT
Address: PO BOX 130940 , CARLSBAD CA
Contact Person:
Name:
Address:
Contractor:
Name: AMERICAN MECHANICAL CORP
Address: PO BOX 1136 , MONROE WA
Contractor License No: AMERIMC071BH
DESCRIPTION OF WORK:
PROVIDE NEW TOILETS
Value of Plumbing /Gas Piping:
Fees Collected:
doc: UPC -10/06
Cityillbf Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
6364200010
2426 SOUTHCENTER MALL TUKW
KEITH SMITH
1725 WESTLAKE AV N, STE 210 , SEATTLE WA
$25,000.00
$202.00
Plumbing
Bathtub or combination bath/shower
Bidet
Clothes washer, domestic
Dental unit, cuspidor
Dishwasher, domestic, with independent drain
Drinking fountain or water cooler (per head)
Food -waste grinder, commercial
Floor drain
Shower, single head trap
Lavatory
Wash fountain
Receptor, indirect waste
Sinks
Urinals
Water Closet
PLUMBING /GAS PIPING PERMIT
FIXTURE TYPE AND QUANTITY
* *continued on next page **
Permit Number:
Issue Date:
Permit Expires On:
Phone:
Phone: 206 713 -4076
Phone: (206)467 -6407
Expiration Date: 01/08/2009
PG08 -083
06/11/2008
12/08/2008
Uniform Plumbing Code Edition: 2006
International Fuel Gas Code Edition: 2006
Plumbing (cont.)
0 Building sewer and each trailer park sewer 0
0 Rain water system - per drain (inside bldg) 0
0 Water heater and/or vent 1
0 Industrial waste treatment interceptor, including
0 its trap and vent, except for kitchen type
0 grease interceptors 0
0 Repair or alteration of water piping and/or water
2 treatment equipment 0
0 Repair or alteration of drainage or vent piping 0
2 Medical gas piping system serving (1 -5)
0 inlets /outlets for a specific gas 0
0 Medical gas piping (6 +) inlets /outlets 0
0 Gas Piping
0 Gas piping outlets (0 -5) 0
2 Gas piping outlets (6 +) 0
PGO8 -083 Printed: 06 -11 -2008
Permit Center Authorized Signature:
Signature:
Print Name:
doc: UPC -10/06
�UL�v /Q p
City (t Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: htip://www.ci.tukwilawa.us
Permit Number: PG08 -083
Issue Date: 06/11/2008
Permit Expires On: 12/08/2008
Date: (v l V4, 01)
I hereby certify that I have read and e u4ted this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied th whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or tly erf orm ce of work. I am authorized to sign and obtain this plumbing /gas piping permit.
Date: 6 //
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PG08 -083 Printed: 06-11 -2008
Parcel No.: 6364200010
Address:
Suite No:
Tenant:
2426 SOUTHCENTER MALL TUKW
LEARNING QUEST TOYS
1: ** *PLUMBING AND GAS PIPING * **
• •
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
PERMIT CONDITIONS
Permit Number:
Status:
Applied Date:
Issue Date:
PG08 -083
ISSUED
03/17/2008
06/11/2008
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila
Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing
inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas
Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code.
Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to
make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless,
adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the
conditioned space shall be insulated to minimum R -3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be
protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing
piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in
accordance with the requirements of the building code.
11: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the
jurisdiction.
doc: Cond -10/06
* * continued on next page **
PG08 -083 Printed: 07 -21 -2008
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating
construction or the performance of work.
Signature:
Print Name:
doc: Cond -10/06
• •
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Date: 7 / 2 ,A
PG08 -083 Printed: 07 -21 -2008
Parcel No.: 6364200010
Address:
Suite No:
Tenant:
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
2426 SOUTHCENTER MALL TUKW
WESTFIELD - VANILLA BOX
1: ** *PLUMBING AND GAS PIPING * **
PERMIT CONDITIONS
Permit Number:
Status:
Applied Date:
Issue Date:
PG08 -083
ISSUED
03/17/2008
06/11/2008
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila
Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing
inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas
Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code.
Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to
make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless,
adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the
conditioned space shall be insulated to minimum R -3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be
protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing
piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in
accordance with the requirements of the building code.
11: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the
jurisdiction.
doc: Cond - 10/06
* *continued on next page **
PG08 -083 Printed: 06 -11 -2008
• •
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work
construction or the performance of work.
Signature:
Print Name:
A2o,d /JU Iri A4o�
doc: Cond -10/06 PG08 -083
Date: - //-6
ordinances governing
or local laws regulating
Printed: 06-11 -2008
CITY OF ,TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.citukwila.wa.us
�j� / King Co Assessor's Tax No.: f -'12e) - -1.rc) ! b
ALA t (.e�r
Site Address:
_ �U.' ) _ V Ad
Tenant Name: I . / i t 1r�J ,�ww
Property Owners Name: ilf ff/i%I/'L1/I/ - ff
Mailing Address: - Afiff r rI �� � X l / � 11i / ad
Company Name:
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
:ER -
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
ev
contac w n you permit s readyyto
Suite Number: 7r5CC5 Floor:
New Tenant: .Yes
City
Sta
Zip
Name: ; ` 1 f ,/�� Day TTelephone: �
Mailing Address: 1 1 .2/1:-
t 61/LC " '` 1(/C / 7A /G r (4/;11f3— ; rea )
E -Mail Address: / 4 in 1 � (9 So,L COI 61.0° Fax Number: ` 9 0 4 7�t � J
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
State
Zip
la
/
City
Day Telephone:
Fax Number: 90 6 46 4-0. (Jv
s�7 ) I 4 Z '1
p mu
e wet stamped by Engineer, ofRecord
intiMAI
Company Name:
Mailing Address:
City State Zip
Contact Person: Day Telephone:
E -Mail Address: _ Fax Number:
Q:WpplicetionsTorms. Applications On Linen -2006 - Pemrit Application.doc
Revised 9 -2006
bh
Page 1 of 6
w t LDNG PERMIT INFOR{MATION` e206 431= x6; 0 ° g �
tt �w.J.' ar. yl � .' of ... �„n ....' �4ef ' (WRl> e a 1 .�i - !t'
an
V l! (J Existing Building Valuation: $
Al Scope ork (please provide detailed information): T.r /447 M4,1 /vi ?G
r c ref t i( 9 eV., p/v' Z Cm-'i A )//'
d tti Ub bi ql e
Valuation of Project (contractor's bid price): $
Will there be new rack storage? ❑ Yes If yes, a separate pe ' d plan submittal will be required.
`,1 Floor:.`
Fl
Basement .
Accessory Structure',
` Garage
.Detached Garage
Attached.Carpoit .;
Detached Carp!)
•
ovide All Building Areas in Square Foo
e Below . •
Covered
Uncoveredleck-
rI -a
PLANNING D ' ' SION;
Existing Interior Remodel:
."Addi • : to
t' ting
cture'
,Type of :.
Construction per
IBC ,..
- Type of
Occupancy, per
IBC.,',.
3
Single family buiding footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
'For an Accessory dwelling, provide the following:
Lot Area (sq ft):
'Provide docum
•
Q:Upplications\Fem s- Applications On linen -2006 - Permit Application.doc
Revised 9-2006
bh
Floor area of principal dwelling: Floor area of accessory dwelling:
Lion that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: & /f'l Compact:
Handicap:
Will there be a change in use? ❑ Yes t ❑ No If `yes ", explain:
FIRE PROTECTION/HAZA OUS MATERIALS:
[)Y Sprinklers Automatic Fire Alarm None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes Eg/ No
If 'yes , attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
Page 2 of 6
Fixture TYPe ��
'Qty'
Fixture T YPe
IL 4e,
:6
Ofixture Type:
Qty
FSxture i £ i s
wQty
Bathtub or combination
bath/shower
Drinking fountain or water
cooler (per head)
Wash fountain
,
Gas piping outlets
Bidet
Food -waste grinder,
commercial
Receptor, indirect
waste
Clothes washer, domestic
Floor drain
2
Sinks
Dental unit, cuspidor
Shower, single head trap
Urinals
Dishwasher, domestic,
with independent drain
Lavatory
,�
Water Closet
n
- !/
Building sewer or trailer
park sewer
Rain water system — per
drain (inside building)
Water heater and/or
vent
�
Additional medical gas
inlets/outlets — six or more
Industrial waste
pretreatment interceptor,
including its trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of water
piping and/or water treating
equipment
Repair or alteration
of drainage or vent
piping
Medical gas piping system
serving one to five
inlets/outlets for specific gas
PLUMBING AND GAS PIPING CONTRACTOR INFORMATION
Company Name:
Mailing Address:
/✓
City
Contact Person: Day Telephone:
E -Mail Address Fax Number:__
Contractor Registration Number: Expiration Date:
Valuation of Plumbing work (contractor's bid price): $ re"
Valuation of Gas Piping work (contractor's bid price): $
Scope of Work (please provide detailed information): pr6V/ 6 nett/ L 7-e fy
Q:1 Applications\Fmms- Applieetions On Line'3 -2106 - Permit Application.doc
Revised 9 -2006
bh
Building Use (per Int'l Building Code):
Occupancy (per Int'l Building Code):
Utility Purveyor: Water:
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
State
Zip
Sewer:
Page 5 of 6
I Date Application Accepted:
Date Application Expires:
r
Staff Initials:
vD
��) `
��� I
/l1 I
Signature:
PERNII.T APPLICATION,NOTES = Applicable to all permits inc this ;application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I lIEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING 0 NER OR AUTHORIZED AGENT:
Print Name:
Mailing Address:
W l�
Q:1Applicmi Farms- Applieatiom On Lind3-2006 - Permit Applicstion.doc
Revised 9.2006
bh
Day Telephon 1f _
Mit Ni Siz %
City
Page 6 of 6
•
Parcel No.:
Address:
Suite No:
Applicant:
Receipt No.: R08 - 02669
Initials: WER
User ID: 1655
Payee:
AMC
TRANSACTION LIST:
Type Method Descriptio
(inn: Raraint -O6
Payment Check 19535
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
6364200010
2426 SOUTHCENTER MALL TUKW
LEARNING QUEST TOYS
RECEIPT
Amount
ACCOUNT ITEM LIST:
Description Account Code
60.00
PLUMBING - NONRES 000.322.103.00.0
Total: $60.00
Permit Number:
Status:
Applied Date:
Issue Date:
Payment Amount:
Payment Date:
Balance:
Current Pmts
60.00
$60.00
PG08 -083
ISSUED
03/17/2008
06/11/2008
07/21/2008 02:35 PM
$0.00
Printpd: 07-71 -7008
Parcel No.:
Address:
Suite No:
Applicant:
Receipt No.:
Initials:
User ID:
Payee:
doc: Receipt -06
City �f Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http://www.ci.tukwila.wa.us
6364200010
2426 SOUTHCENTER MALL TUKW
WESTFIELD - VANILLA BOX
R08 -02234
WER
1655
AMC
TRANSACTION LIST:
Type Method Descriptio
Payment Check 19445
ACCOUNT ITEM LIST:
Description Account Code
RECEIPT
Amount
60.00
PLUMBING - NONRES 000.322.103.00.0
Permit Number:
Status:
Applied Date:
Issue Date:
Payment Amount:
Payment Date:
Balance:
Current Pmts
60.00
Total: $60.00
$60.00
4050 06/24 9710 TOTAL
PG08 -083
ISSUED
03/17/2008
06/11/2008
06/23/2008 03:05 PM
$0.00
360.00
Printed: 06 -23 -2008
RECEIPT NO: RO8 -02070
Initials: JEM
User ID: 1165
Payee: AMC
SET TRANSACTIONS:
Set Member Amount
ACCOUNT ITEM LIST:
Description
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: //www. ci. tukwila. wa. us
ugan 83 164.00
PG08 -085 164.00
PG08 -086 188.00
PG08 -104 164.00
PG08 -10.5 164.00
PG08 -128 512.00
PG08 -129 512.00
PG08 -130 512.00
PGO8 -131 512.00
PGO8 -132 512.00
TOTAL: 3,404.00
PLAN CHECK - NONRES
PLUMBING - NONRES
SET RECEIPT
Payment Date: 06/11/2008
Total Payment: 3,404.00
SET ID: 0611 SET NAME: WESTFIELD PLUMBING
TRANSACTION LIST:
Type Method Description Amount
Payment Check 19416 3,404.00
TOTAL: 3,404.00
Account Code Current Pmts
000/345.830 1,800.00
000.322.103.00.0 1,604.00
TOTAL: 3,404.00
3538 06/11 9711 TOTAL 3404°00
r, -... o rre rmc no
RECEIPT NO: R08 -00793
Initials: JEM
User ID: 1165
Payee: ERIK S BARTH
SET TRANSACTIONS:
Set Member Amount
D08 -142 862.94
EL08 -260 123.00
� -081 101.50
., . 083 38.00
TOTAL: 1,125.44
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http. //www.ci.tukwila.wa.us
SET ID: S000000982 SET NAME: Tmp set/Initialized Activities
TRANSACTION LIST:
Type Method Description Amount
Payment Check 217
ACCOUNT ITEM LIST:
Description
ELECTRICAL PLAN - NONRES
PLAN CHECK - NONRES
SET RECEIPT
TOTAL:
•
Payment Date: 03/17/2008
Total Payment: 1,125.44
1,125.44
1,125.44
Account Code Current Pmts
000.345.832.00.0 123.00
000/345.830 1,002.44
TOTAL: 1,125.44
Project:
L eAR6u►N6:.
Type of Inspection:
i tNA k-- PI (Q. ill k)
Address:
0,14Z7_ MAO
Date Called:
Special Instructions:
Date Wanted:
--- 2 3 --
m.
Requester:
Phone No: _ -
206. --
^�/
r �
z
INSPECTION RECORD
Retain a copy with permit U (- - U
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION f
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367
INSPECTION NO.
COMMENTS:
/C4/7 ed eorktp/e7
Approved per applicable codes. El Corrections required prior to approval.
ri $60 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
pai at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Inspector: n
Date:
Receipt No.:
Date:
COMMENTS: l 7
DL
Address:
Date Called:
V 0 : ?1r
NT t 4>d.rA3-Q_
Qa2 Dere-
0L - v 'LJ &
Phone No:
,-66 - 02 -7 /vz J
CAF �. ..
;•
g -0 -60...„) .„1,, 6 ,
0 tc -
isiorirt ork,ii.--
i oce.„
% r,“."tok
1
I
1
Project: / J 04-
t
Type I I ns ly -. n! �,
A/ 17 l
Address:
Date Called:
Special Instructions:
Date Wanted:
60 --/ '. Q62
a.m
p.m.
Requester:
Phone No:
,-66 - 02 -7 /vz J
1
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO. '
CITY OF TUKWILA BUILDING DIVISION -
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
g Approved per applicable codes. 0 Corrections required prior to approval.
Inspector:
Date:
o$
❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
aT� u" v�`�a:�.
ACTIVITY NUMBER: PG08 -083 DATE: 07 -11 -08
PROJECT NAME: LEARNING QUEST TOYS
SITE ADDRESS: 2426 SOUTHCENTER MALL
Original Plan Submittal
Response to Incomplete Letter #
Response to Correction Letter # X Revision # 2 After Permit Issued
DEPARTMENTS:
M 1-1
Buildin Division
Public W rks
� (�. �4`S - 045
Complete
TUES/THURS ROUTING:
Please Route
REVIEWER'S INITIALS:
APPROVALS OR CORRECTIONS:
Approved
Notation:
REVIEWER'S INITIALS:
Documents/routing slip.doc
2 -28 -02
° PERMIT COORD P
CO Y
PLAN REVIEW /ROUTING SLIP
Approved with Conditions
Fire Prevention
Structural
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Incomplete
Structural Review Required
n
DATE:
DATE:
Planning Division
Permit Coordinator
DUE DATE: 07 -15 -08
Not Applicable
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
❑ No further Review Required
DUE DATE: 08-12 -08
Not Approved (attach comments) n
Permit Center Use Only •
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
ACTIVITY NUMBER: PG08 -083 DATE: 06 -16 -08
PROJECT NAME: WESTFIELD VANILLA BOX
SITE ADDRESS: 2426 SOUTHCENTER MALL
Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter # X Revision # 1 after Permit Issued
DEPARTMENTS:
B iii g
'vision
Public Works
nitt
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
LETTER OF COMPLETENESS MAILED:
TUES/THURS ROUTING:
Please Route Structural Review Required
REVIEWER'S INITIALS:
APPROVALS OR CORRECTIONS:
Approved 17f Approved with Conditions
Notation:
REVIEWER'S INITIALS:
Documents/routing slip.doc
2 -28 -02
� i'�RMIT COORD COPYf
PLAN REVIEW /ROUTING SLIP
Fire Prevention n Planning Division n
Structural
Incomplete n
DATE:
Permit Coordinator
DUE DATE: 06-17-08
Not Applicable n
No further Review Required
DUE DATE: 07-15-08
Not Approved (attach comments)
DATE:
n
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
ACTIVITY NUMBER: PG08 - 083
PROJECT NAME: WESTFIELD VACANT SPACE
SITE ADDRESS: 2426 SOUTHCENTER MALL
X Original Plan Submittal
Response to Correction Letter #
DATE: 03 -17 -08
Response to Incomplete Letter #
Revision # After Permit Issued
DEPARTMENTS:
kivt9
Bu11di ig D sion
Public Works
HERMIT COORD COPY �
PLAN REVIEW /ROUTING SLIP
Comments:
Fire Prevention
Structural
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete IA Incomplete
Planning Division
Permit Coordinator
DUE DATE: 03-20-08
Not Applicable
n
Permit Center Use Only
INCOMPLETE LETTER MAILED:
Departments determined incomplete: Bldg ❑
LETTER OF COMPLETENESS MAILED:
Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route
REVIEWER'S INITIALS:
APPROVALS OR CORRECTIONS:
Approved
Notation:
REVIEWER'S INITIALS:
Documents/routing slip.doc
2 -28 -02
d
Structural Review Required
Approved with Conditions
No further Review Required
DATE:
DUE DATE: 04-17-08
Not Approved (attach comments)
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑
Staff Initials:
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITI S
2
7 - 11-06
i - fit -OK
Ute
Summary of Revision: - te1,6110N of 121t/C 'novvA '. vl frn. - wfizgv h l fr&pkw.- Kv r )
Received by: J 7 ,��
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
2
7 - 11-06
i - fit -OK
Ute
Summary of Revision:
Received by:
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
2
7 - 11-06
i - fit -OK
Ute
Summary of Revision: Cl v ve 3-o TT
Received by:
y: ,o,��r� L �.,..._
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
Summary of Revision:
Received by:
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
Summary of Revision:
Received by:
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
Summary of Revision:
Received by:
PROJECT NAME:
SITE ADDRESS:
if I Lid A
REVISION LOG
PERMIT NO: P(5b51f0
ORIGINAL ISSUE DATE: alt jL j 1?
(please print)
(please print)
(please print)
(please print)
(please nrintl
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila Washington 98188
Phone: 206- 431 -3670
Fax: 206- 431 -3665
Web site: http: / /www.c'i.tukwila.wa.us
Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through
the mail, fax, etc.
Date: 7A/ /D Plan Check/Permit Number:
❑ Response to Incomplete Letter #
❑ Response to Correction Letter #
Revision # 2- after Permit is Issued
❑ Revision requested by a City Building Inspector or Plans Examiner
■applicationslforms= applications on line revis96a "submittal
Created: 8 -13 -2004
e.: 4 ' s T y5
04-4-y 4e.-Q : J 41
•
.r.
Thee/Got SA t
Pay _- OiP3
Steven M. Mullet, Mayor
Steve Lancaster, Director
Project Name: Leay-,7; () 4 esi- TES l- 'Iri �er4 ec,le,,s/- ,..k vgHi 114 &
Project Address: Z ce- 1 4 e -s, 7
A � S o�,� - � �lI
Contact Person: Q 4.- e—t'et- PL/v Phone Number: e/ s" -1-7 a-- 8,2..3
Summary of Revision:
6/74 nn e V441; /14 Be x
(S4 /es r 3/ S/ 218
RECSVED
f Tu}yiA
JUL 11 1006
Sheet Number(s):
"Cloud" or highlight all areas of revision including date of revision
Received at the City of Tukwila Permit Center by:
Entered in Permits Plus on _ _ I I Q
r C=ENTER
Date:
❑
El
Sheet Number(s): P
City of Tukwila
Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through
the mail, fax, etc.
❑ Response to Incomplete Letter
Response to Correction Letter #
Revision # f after Permit is Issued
Revision "requested by a City Building Inspector �r Plans Examiner
Project Name : 1A) e RT' rg i e;t (/ G zit � ' // el? r�c7 y
Project Address : 2
Contact Person: Q,—,' a Pd�df'em= , Phone Number: C X 842 —6671
Summary of Revision: Re-e-) i 51 5 (a u d e-
PI u G i ' t v / lam„ i- - ; 5 e--e_ v Yea. c / /Y - d e fe.r4 0�, _ a m
7 i 4 roc. _J-� -_
l'Oa,5 _ i-'I s e_."- - � « =r- ,, q 4-7-- 0 5 d%4 ;1 )-e4 > S a
7 re /24,- c% /e.Ae o f 0, 7‘; 1 '
"Cloud" or highlight all areas of revision including date o
Received at the City of Tukwila Permit Center by
Entered in Permits Plus on 0(D(RfI
kapplications\fomu- applications on line revision submittal
Created: 8 -13 -2004
Department of Community Development
6300 Southcenter Boulevard Suite #i 00
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206- 431 -3665
Web site: http : //www.ci.tukwila.wa.us
Plan Check/Permit Number: P6 Off - Og3
revision
Steven M. Mullet, Mayor
Steve Lancaster, Director
RECEIVED
CITY OF TUKWIfA
1 JUN 16 2008
rtrtlwi I k•tM l kh
License Information
License
AMERIMC071BH
Licensee Name
AMERICAN MECHANICAL CORP
Licensee Type
CONSTRUCTION CONTRACTOR
UBI
601433818
Ind. Ins. Account Id
53821001
Business Type
CORPORATION
Address 1
PO BOX 1136
Address 2
City
MONROE
County
SNOHOMISH
State
WA
Zip
982724136
Phone
2064676407
Status
ACTIVE
Specialty 1
BOILER/STEAM FIT/PROC PIPING
Specialty 2
PLUMBING
Effective Date
1/8/1993
Expiration Date
1/8/2009
Suspend Date
Separation Date
Parent Company
Previous License
Next License
Associated License
Business Owner Information
Name
Role
Effective Date
Expiration Date
KING, CHERI L
PRESIDENT
01/08/1993
KING, KELLY E
TREASURER
01/08/1993
Look Up a Contractor, Electra aan or Plumber License Detail
Washington State Department of Labor and Industries
General/Specialty Contractor
A business registered as a construction contractor with L &I to perform
construction work within the scope of its specialty. A General or Specialty
construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Bond Information
Bond
Bond
Company
Name
Bond
Account
Number
Effective
Date
Expiration
Date
Cancel
Date
Impaired
Date
Bond
Amount
Received
Date
OLD
REPUBLIC
SURETY
Until
•
Page 1 of 2
https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= AMERIMC071BH 06/11/2008
PLU v1BING FIXTURE SCHEDULE
PLAN MARK
MANUFACTURER
MODEL NUMBER
NOTES
WC
AMERICAN STANDARD
#2168.100
C/W SUPPLY PIPING, ANGLE VALVE, WALL FLANGE AND FLEXIBLE RISER. (ZURN ZH- 8825— CR —LK) SEAT OLSONITE #46SSTL
LAV
ADVANCE
7 —PS -50
STAINLESS STEEL SINK, LEVER OPERATED DRAIN K -26, S.S. BASKET K -6, ADVANCE FAUCET K -9,
WH
A.O. SMITH
ELJF -10
1.0 —G.A. STORAGE CAPACITY, 3.0 INPUT, 208V. ELECTRIC WATER HEATER
FD
ZURN
ZN-- 415 --6S
CAST WITH DEEP SEAL TRAP AND 6" STRAINER
TP
PPP INC.
#PR -500
FULLY AUTOMATIC, ALL BRASS TRAP PRIMER VALVE, ACTIVATED BY A DROP IN BUILDING WATER PRESSURE, NO AJUSTMENT REQUIRED,
MODEL PRIME —RITE FOR 1 TO 4 TRAPS WITH DISTRIBUTION UNIT. MUST BE INSTALLED ON A FRESH COLD WATER LINE OF 1 1/2"
DIAMETER OR LESS, AS INDICATED ON DRAWINGS, OR REQUIRED BY PLUMBING CODE.
WCO
ZURN
--
WALL CLEAN OUT —CAST IRON CLEAN OUT TEE WITH BRONZE THREADED CLEAN OUT PLUG. PLUG TO BE GAS AND WATER TIGHT. WALL
ACCESS PANEL — ZURN #ZANB- 1460 -9 9 "x9" WALL ACCESS PANEL AND FRAME: SMOOTH NICKEL BRONZE SECURING LUGS.
GENERAL PLUvIBI\
G
OTES
1. ALL PLUMBING INSTALLATIONS SHALL COMPLY WITH STATE AND LOCAL CODES.
2. PLUMBING CONTRACTOR SHALL MAKE CORRECTIONS IF WATER SUPPLY AND DRAINAGE FOR THE
BUILDING ARE REVERSED.
3. INSTALL ALL THREADED CLEANOUT PLUGS WITH PIPE DOPE TO ALLOW EASY REMOVAL IN THE
FUTURE.
4. IT WILL BE THE RESPONSIBIUTY OF THE PLUMBING CONTRACTOR TO INSURE THAT ITEMS TO BE
FURNISHED UNDER PLUMBING CONTRACT WILL FIT THE SPACE AVAILABLE — PLUMBING CONTRACTOR
SHALL MAKE NECESSARY FIELD MEASUREMENTS TO ASCERTAIN SPACE REQUIREMENTS, INCLUDING
THOSE FOR CONNECTIONS AND SHALL FURNISH AND INSTALL SUCH SIZES AND SHAPES OF
EQUIPMENT THAT ARE THE TRUE INTENT OF THE DRAWINGS AND SPECIFICATIONS.
5, GENERAL CONTRACTOR SHALL PROVIDE ALL OPENINGS IN WALLS, FLOORS, AND ROOF WITH
EACH CONTRACTOR RESPONSIBLE FOR VERIFYING LOCATION AND SIZES OF ALL OPENINGS
REQUIRED UNDER HIS CONTRACT, UNLESS NOTED OTHERWISE ON THE PLANS.
6. PLUMBING CONTRACTOR SHALL PROVIDE PRESSURE REDUCING VALVE, SWEAT TYPE, 30 -60 P51G
DISCHARGE RANGE WHERE REQUIRED BY LOCAL CODES.
7, ALL PLUMBING FIXTURES SHALL BE NEATLY CAULKED WITH SILICONE COMPOUND WHERE FIXTURE
MEETS WALL.
8. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ELECTRICAL AND CONTROL
CONNECTIONS TO PLUMBING EQUIPMENT WITH THE ELECTRICAL CONTRACTOR. SEE PLANS FOR
LOCATIONS OF JUNCTION BOXES, DISCONNECTS, AND CIRCUIT BREAKERS (PANEL BOARDS). TYPE,
SIZE AND NUMBER OF CONDUCTORS AND CONDUITS TO EQUIPMENT SHALL BE COORDINATED WITH Sc
VERIFIED BY THE ELECTRICAL CONTRACTOR. IN CASE OF PLUMBING EQUIPMENT CONNECTION TO A
CIRCUIT BREAKER, THE NUMBER AND SIZE OF CONDUCTORS AND CONDUIT SHALL CONFORM TO THE
LATEST NATIONAL ELECTRICAL CODE REGULATIONS. ALL MOTOR STARTERS, SWITCHES, CONTROL
DEVICES, ETC., PROVIDED BY THIS CONTRACTOR SHALL BE RECESSED IN THE WALLS, EXCEPT WHERE
THESE ITEMS ARE LOCATED IN MECHANICAL ROOMS. PROVIDE NAMEPLATES FOR ALL EQUIPMENT,
SWITCHES, CONTROL DEVICES, ETC.
9. PLUMBING CONTRACTOR SHALL SUPPLY AND INSTALL GAS PIPING IF SHOWN ON PLANS. ALL GAS
PIPING SHALL COMPLY WITH LOCAL CODES. PLUMBING CONTRACTOR SHALL MAKE FINAL
CONNECTIONS TO ALL EQUIPMENT. INSTALL REGULATORS AT EQUIPMENT WHERE REQUIRED BY
MANUFACTURER OR CUTS SUPPLIED BY FURNISHING CONTRACTOR.
10. PLUMBING CONTRACTOR SHALL INSTALL SHOCK ABSORBERS AT PLACES INDICATED ON THE
PLANS AND RISER DIAGRAM. SHOCK ABSORBERS SHALL BE PDI APPROVED.
11. ALL UNDERGROUND DRAINAGE, WASTE AND VENT PIPE SHALL BE CAST IRON OR PVC AS
ALLOWED BY LOCAL CODES. ALL ABOVE GROUND DRAINAGE, WASTE AND VENT PIPE SHALL BE PVC.
12. CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR APPROVED FLOOR PLAN AND
DIMENSIONS. DO NOT SCALE PLUMBING DRAWINGS.
13. CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING CONDENSATE DRAIN PIPING ON AIR
HANDLING UNITS. COORDINATE WORK WITH MECHANICAL CONTRACTOR.
14. CONTRACTOR SHALL INSTALL WATER PIPING SD THAT PIPE JOINTS ARE NOT UNDER FLOOR
SLAB.
15. PIPE INSULATION SHALL BE CONTINUOUS THROUGH WALLS OR FLOOR.
16. CONTRACTOR SHALL TEST SOIL, WASTE AND VENT SYSTEMS WITH PEPPERMINT. ALL MECHANICAL
SYSTEMS SHALL BE RUNNING WHILE THESE TESTS ARE BEING MADE.
CONTRACTOR SHALL FURNISH A CERTIFICATE OF COMPLIANCE AND ACCEPTANCE OF
THESE TESTS.
17. CONTRACTOR SHALL INSULATE ALL UNDER SLAB HOT WATER PIPING WITH 1" RIGID URETHANE
FOAM INSULATION AND 1" CLOSED CELL RUBBER INSULATION, WITH FIRE RETARDANT COATING ON
ALL HOT WATER AND RETURNS LINES ABOVE SLAB. INSULATE ALL COLD WATER LINES ABOVE SLAB
WITH 1/2" CLOSED CELL RUBBER FIRE RETARDANT INSULATION.
18. ANY DEVIATIONS FROM SPECIFIED PLUMBING FIXTURES AND TRIM IN FIXTURE SCHEDULE SHALL
BE APPROVED PRIOR TO SUBMITTAL FROM THE ALDO'S PROJECT MANAGER.
19. ALL INDIRECT WASTE LINES SHALL HAVE A MINIMUM OF 2" VERTICAL AIR GAP AT FLOOR SINK,
DRAIN OR HUB. FLOOR SINKS, DRAINS OR HUBS SHALL EXTEND A MINIMUM 1" ABOVE FINISHED
FLOOR WHEN SERVING INDIRECT DRAINS.
20. VACUUM BREAKERS SHALL BE INSTALLED ON ALL HOSE BIBBS AND HYDRANTS. VACUUM
BREAKERS /BACK FLOW PREVENTORS TO BE INSTALLED AT ANY POINT WHERE THERE IS DANGER OF
THE NON POTABLE WATER SYSTEM COMING IN CONTACT WITH THE PORTABLE WATER SYSTEM OR
ANY DANGER OF BACK FLOW. COORDINATE WITH LOCAL INSPECTOR.
21. ALL PLUMBING WORK SHALL BE COORDINATED WITH OTHER PROJECT CONTRACTORS BEFORE
INSTALLATION.
22. USE TYPE "K" SOFT DRAWN COPPER UNDER SLAB.
23. ALL WATER DISTRIBUTION PIPE ABOVE GROUND SHALL BE COPPER OR COPPER ALLOY TUBING.
VACUUM RELIEF VAVLE (VALVE
AND TEE ABOVE WATER HEATER)
TACO CX -15 EXPANSION TANK,
FDA AND ASME APPROVED
FOR POTABLE WATER.
•
.1"
WATER RISER DIAGRAM
2 I
PROVIDE BALL VALVE.
UNION
10 GALLON WATER HEATER ABOVE
TOILET CEILING. PROVIDE .3"
DEEP GALV PAN W /SOLDERED
SEAMS.
TERMINATE INDIRECTLY
INTO FLOOR DRAIN
ROUTE AUX. DRAIN TO APPROVED
RECEPTOR SUCH AS TATTLETAIL DRAIN
ETC. WATER HEATER T & P AND DRAIN
PAN CANNOT CAUSE TRIPPING HAZARD.
VERIFY EXACT LOCATION IN FIELD.
TO TRAP PRIMER
CONNECTION AT FD
LAV
cs-o4t.
l
EXTEND NEW 4" SS TO EXISTING
SYSTEM, VERIFY EXACT LOCATION,
FLOW AND DEPTH.
EXTEND NEW 4" SS TO EXISTING
SYSTEM, VERIFY EXACT LOCATION,
FLOW AND DEPTH.
3"
N I
i
N
WC
r PLUMBING PLAN
3" FD
W /TRAP
PRIMER
PROVIDE AND INSTALL
4" V.T.R.
i
ED
O
LAV
WC (
if- _- .............:............1£. .
WASTE RISER DIAGRAM
101
I o
= ..
Na change '
of work w thOiJt p rloi cap14Dr�71,"�I O `
Tukwila Building Div
NOTE: Revisions will require a neW P!? ►s usand Revisions
i! and may include additions! plan re'r'n,�t 1(37
�P�I7`ate
a
FILE copy
Permit No. Yig<0.&012.
Ply revit?w approval is subject to errors and omissions.
Approval of construction documents does not authorize
the violation of any adopt- • * y • - or o • *4. flemVt
a; approved C . d , . $. ., �, _ Meted:
Data:
- oe
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
JUN 16 2008
PERMIT CENTER
2426 Southcenter Mall
Tukwila, WA 98188
smith cc
318 terry avenue n
seattle, washington 98109
206.838.5485 p
206.713.4076 m
206.464.0700 f
ksmith@smithco.org
http: / /www.smithco.org/
Consultant
Consultant Registration
1 02.08.08
2 03.26.08
3 04.07.08
4 04.21.08
5 05.30.08
Project Name
Issues
6294
WESTFIELD SOUTHCENTER MALL
Project Number 02008018.00
Description PLUMBING PLAN
Computer File CW05- 2008— P1,DWG
Scale AS NOTED
Template
P -1
Architect Registration
By Check
PERMIT KLS
BLDG. COMMENTS KLS
PERMIT CORR. KLS
OWNER REVISIONS KLS
ISSUE KLS
All ideas, designs, arrangements, and plans indicated or
represented by this drawing are owned by and the property of
smith co. IIc and were created, evolved, and developed
for use on and in connection with the specified project. None of
such ideas, designs, arrangements or plans shall be used
by or disclosed to any person, firm, or corporation for any
purpose whatsoever without the written permission of smith co. IIc.
PLUvIBII\C FIXTURE SCHEDULE
PLAN MARK
MANUFACTURER
MODEL NUMBER
NOTES
WC
AMERICAN STANDARD
#2168.100
C/W SUPPLY PIPING, ANGLE VALVE, WALL FLANGE AND FLEXIBLE RISER. (ZURN ZH- 8825- CR -LK) SEAT OLSONITE #4655T1
LAV
ADVANCE
7 -PS -50
STAINLESS STEEL SINK, LEVER OPERATED DRAIN K -26, S.S. BASKET K -6, ADVANCE FAUCET K-9,
WH
A.O. SMITH
ELJF -10
1.0 --G.A. STORAGE CAPACITY, 3.0 INPUT, 208V. ELECTRIC WATER HEATER
FD
ZURN
ZN- 415 -6S
CAST WITH DEEP SEAL TRAP AND 6" STRAINER
TP
PPP INC.
#PR -500
FULLY AUTOMATIC, ALL BRASS TRAP PRIMER VALVE, ACTIVATED BY A DROP IN BUILDING WATER PRESSURE, NO AJUSTMENT REQUIRED,
MODEL PRIME -RITE FOR 1 TO 4 TRAPS WITH DISTRIBUTION UNIT. MUST BE INSTALLED ON A FRESH COLD WATER LINE OF 1 1/2"
DIAMETER OR LESS, AS INDICATED ON DRAWINGS, OR REQUIRED BY PLUMBING CODE.
WCO
ZURN
__
WALL CLEAN OUT -CAST IRON CLEAN OUT TEE WITH BRONZE THREADED CLEAN OUT PLUG. PLUG TO BE GAS AND WATER TIGHT. WALL
ACCESS PANEL - ZURN #ZANB- 1460 -9 9 "x9" WALL ACCESS PANEL AND FRAME: SMOOTH NICKEL BRONZE SECURING LUGS.
GENERAL PLU
V
BING NOTES
1. ALL PLUMBING INSTALLATIONS SHALL COMPLY WITH STATE AND LOCAL CODES.
2. PLUMBING CONTRACTOR SHALL MAKE CORRECTIONS IF WATER SUPPLY AND DRAINAGE FOR THE
BUILDING ARE REVERSED.
3. INSTALL ALL THREADED CLEANOUT PLUGS WITH PIPE DOPE TO ALLOW EASY REMOVAL IN THE
FUTURE.
4. IT WILL BE THE RESPONSIBILITY OF THE PLUMBING CONTRACTOR TO INSURE THAT ITEMS TO BE
FURNISHED UNDER PLUMBING CONTRACT WILL FIT THE SPACE AVAILABLE - PLUMBING CONTRACTOR
SHALL MAKE NECESSARY FIELD MEASUREMENTS TO ASCERTAIN SPACE REQUIREMENTS, INCLUDING
THOSE FOR CONNECTIONS AND SHALL FURNISH AND INSTALL SUCH SIZES AND SHAPES OF
EQUIPMENT THAT ARE THE TRUE INTENT OF THE DRAWINGS AND SPECIFICATIONS.
5. GENERAL CONTRACTOR SHALL PROVIDE ALL OPENINGS IN WALLS, FLOORS, AND ROOF WITH
EACH CONTRACTOR RESPONSIBLE FOR VERIFYING LOCATION AND SIZES OF ALL OPENINGS
REQUIRED UNDER HIS CONTRACT, UNLESS NOTED OTHERWISE ON THE PLANS.
6. PLUMBING CONTRACTOR SHALL PROVIDE PRESSURE REDUCING VALVE, SWEAT TYPE, 30 -60 PSIG
DISCHARGE RANGE WHERE REQUIRED BY LOCAL CODES.
7. ALL PLUMBING FIXTURES SHALL BE NEATLY CAULKED WITH SILICONE COMPOUND WHERE FIXTURE
MEETS WALL.
8. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ELECTRICAL AND CONTROL
CONNECTIONS TO PLUMBING EQUIPMENT WITH THE ELECTRICAL CONTRACTOR. SEE PLANS FOR
LOCATIONS OF JUNCTION BOXES, DISCONNECTS, AND CIRCUIT BREAKERS (PANEL BOARDS). TYPE,
SIZE AND NUMBER OF CONDUCTORS AND CONDUITS TO EQUIPMENT SHALL BE COORDINATED WITH &
VERIFIED BY THE ELECTRICAL CONTRACTOR. IN CASE OF PLUMBING EQUIPMENT CONNECTION TO A
CIRCUIT BREAKER, THE NUMBER AND SIZE OF CONDUCTORS AND CONDUIT SHALL CONFORM TO THE
LATEST NATIONAL ELECTRICAL CODE REGULATIONS. ALL MOTOR STARTERS, SWITCHES, CONTROL
DEVICES, ETC., PROVIDED BY THIS CONTRACTOR SHALL BE RECESSED IN THE WALLS, EXCEPT WHERE
THESE ITEMS ARE LOCATED IN MECHANICAL ROOMS. PROVIDE NAMEPLATES FOR ALL EQUIPMENT,
SWITCHES, CONTROL DEVICES, ETC.
9. PLUMBING CONTRACTOR SHALL SUPPLY AND INSTALL GAS PIPING IF SHOWN ON PLANS. ALL GAS
PIPING SHALL COMPLY WITH LOCAL CODES. PLUMBING CONTRACTOR SHALL MAKE FINAL
CONNECTIONS TO ALL EQUIPMENT. INSTALL REGULATORS AT EQUIPMENT WHERE REQUIRED BY
MANUFACTURER OR CUTS SUPPLIED BY FURNISHING CONTRACTOR.
10. PLUMBING CONTRACTOR SHALL INSTALL SHOCK ABSORBERS AT PLACES INDICATED ON THE
PLANS AND RISER DIAGRAM. SHOCK ABSORBERS SHALL BE PD1 APPROVED.
11. ALL UNDERGROUND DRAINAGE, WASTE AND VENT PIPE SHALL BE CAST IRON OR PVC AS
ALLOWED BY LOCAL CODES. ALL ABOVE GROUND DRAINAGE, WASTE AND VENT PIPE SHALL BE PVC.
12. CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR APPROVED FLOOR PLAN AND
DIMENSIONS. DO NOT SCALE PLUMBING DRAWINGS.
13. CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING CONDENSATE DRAIN PIPING ON AIR
HANDLING UNITS. COORDINATE WORK WITH MECHANICAL CONTRACTOR.
14. CONTRACTOR SHALL INSTALL WATER PIPING 50 THAT PIPE JOINTS ARE NOT UNDER FLOOR
SLAB.
15. PIPE INSULATION SHALL BE CONTINUOUS THROUGH WALLS OR FLOOR.
16. CONTRACTOR SHALL TEST SOIL, WASTE AND VENT SYSTEMS WITH PEPPERMINT. ALL MECHANICAL
SYSTEMS SHALL BE RUNNING WHILE THESE TESTS ARE BEING MADE.
CONTRACTOR SHALL FURNISH A CERTIFICATE OF COMPLIANCE AND ACCEPTANCE OF
THESE TESTS.
17. CONTRACTOR SHALL INSULATE ALL UNDER SLAB HOT WATER PIPING WITH 1" RIGID URETHANE
FOAM INSULATION AND 1" CLOSED CELL RUBBER INSULATION, WTH FIRE RETARDANT COATING ON
ALL HOT WATER AND RETURNS UNES ABOVE SLAB. INSULATE ALL COLD WATER LINES ABOVE SLAB
WITH 1/2" CLOSED CELL RUBBER FIRE RETARDANT INSULATION.
18. ANY DEVIATIONS FROM SPECIFIED PLUMBING FIXTURES AND TRIM IN FIXTURE SCHEDULE SHALL
BE APPROVED PRIOR TO SUBMITTAL FROM THE ALDO'S PROJECT MANAGER.
19. ALL INDIRECT WASTE LINES SHALL HAVE A MINIMUM OF 2" VERTICAL AIR GAP AT FLOOR SINK,
DRAIN OR HUB. FLOOR SINKS, DRAINS OR HUBS SHALL EXTEND A MINIMUM 1" ABOVE FINISHED
FLOOR WHEN SERVING INDIRECT DRAINS.
2D. VACUUM BREAKERS SHALL BE INSTALLED ON ALL HOSE BIBBS AND HYDRANTS. VACUUM
BREAKERS /BACK FLOW PREVENTORS TO BE INSTALLED AT ANY POINT WHERE THERE IS DANGER OF
THE NON POTABLE WATER SYSTEM COMING IN CONTACT WITH THE PORTABLE WATER SYSTEM OR
ANY DANGER OF BACK FLOW. COORDINATE WTH LOCAL INSPECTOR.
21. ALL PLUMBING WORK SHALL BE COORDINATED WITH OTHER PROJECT CONTRACTORS BEFORE
INSTALLATION.
22. USE TYPE "K" SOFT DRAWN COPPER UNDER SLAB.
23. ALL WATER DISTRIBUTION PIPE ABOVE GROUND SHALL BE COPPER OR COPPER ALLOY TUBING.
VACUUM RELIEF VAVLE (VALVE
AND TEE ABOVE WATER HEATER)
TACO CX -15 EXPANSION TANK,
FDA AND ASME APPROVED
FOR POTABLE WATER.
SCALE: N.T.S.
WC
TO TRAP PRIMER
CONNECTION AT FD
FD
LAV
WATER RISER DIAGRAM
PROVIDE BALL VALVE.
UNION
10 GALLON WATER HEATER ABOVE
TOILET CEILING. PROVIDE 3"
DEEP GALV PAN W /SOLDERED
SEAMS.
TERMINATE INDIRECTLY
INTO FLOOR DRAIN
ROUTE AUX. DRAIN TO APPROVED
RECEPTOR SUCH AS TATTLETAIL DRAIN
ETC. WATER HEATER T & P AND DRAIN
PAN CANNOT CAUSE TRIPPING HAZARD.
VERIFY EXACT LOCATION IN FIELD.
WC
3
TO TRAP PRIMER
CONNECTION AT FD
FD
LAV
EXTEND NEW 4" SS TO EXISTING
SYSTEM, VERIFY EXACT LOCATION,
FLOW AND DEPTH.
r —PROVIDE AND INSTALL
JIL V.T.R.
3" FD
W /TRAP
PRIMER
LAV
SCALE: N.T.S.
EXTEND NEW 4" SS TO EXISTING
SYSTEM, VERIFY EXACT LOCATION,
FLOW AND DEPTH.
3" FD
W /TRAP
PRIMER
I
>I
WC
LAV
WC
WASTE RISER DIAGRAM
PLUMBING PLAN
SCALE: 1 /4" = 1' -0"
l
BEMs____
No changes shall be made to the scope
of work without prior approval of
Tukwila Budding Division.
�; Revisions wilt require a new plan submittal
N and may include additional plan rev1ew fees.
FILE OPY
Permit No.
City of Tukwila
BUILDING DIVISION
SEPARATE PERMIT
REQUIRED FOR:
hanical
Electrical
Plumbing
0 Gas piping
City of Tukwila
BUILDING DIVISION
RECEIVED
m� - O ?nns
Pu[3L: c
2426 Southcenter Mall
Tukwila, WA 98188
smith Co.
318 terry avenue n
seattle, washington 98109
206.838.5485 p
206.713.4076 m
206.464.0700 f
ksmith @smithco.org
http: / /www.smithco.org/
Consultant
Consultant Registration
Issues and Revisions
No. Date
1
th 0
Plar review approval is subject to errors and orris.
Approval of construtlian documents does not authorize
the violation of any adopted code or ordinance. i'Ipt
of approved F ; • arpd corms is
By
Date:
02.08.08
6294
Project Name
Project Number 02008018,00
WESTFIELD SOUTHCENTER MALL
Description PLUMBING PLAN
Computer File CW05- 2008— P1.DWG
Scale AS NOTED
P -1
REGISTERED
ARCH4TECT
El I
STATE OF WASHINGTON
Architect Registration
Issues By Check
PERMIT KLS
RECEIVED
CiTY OF TUKWILA
MAR 1 1 'LUUU
Template 4.3 (120101) PERMIT CENTER
All ideas, designs, arrangements, and plans indicated or
represented by this drawing are owned by and the property of
smith co. IIc and were created, evolved, and developed
for use on and in connection with the specified project. None of
such ideas, designs, arrangements or plans shall be used
by or disclosed to any person, firm, or corporation for any
purpose whatsoever without the written permission of smith co. Ho.