HomeMy WebLinkAboutPermit PG08-086 - WESTFIELD SOUTHCENTER MALL - BOSS WEARBOSS WEAR
2876 SOUTHCENTER MALL
PGO8-086
Parcel No.: 6364200010
Address:
Suite No:
CitAf Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
PLUMBING /GAS PIPING PERMIT
2876 SOUTHCENTER MALL TUKW
Permit Number:
Issue Date:
Permit Expires On:
PG08 -086
06/11/2008
12/15/2008
Tenant:
Name: BOSS WEAR
Address: 2876 SOUTHCENTER MALL , TUKWILA WA
Owner:
Name: WESTFIELD PROPERTY TAX DEPT
Address: PO BOX 130940 , CARLSBAD CA
Contact Person:
Name: KEITH SMITH
Address: 1725 WESTLAKE AVE N , SEATTLE WA
Contractor:
Name: AMERICAN MECHANICAL CORP
Address: PO BOX 1136 , MONROE WA
Contractor License No: AMERIMC071BH
Phone:
Phone: 206 - 713 -4076
Phone: (206)467 -6407
Expiration Date: 01/08/2009
DESCRIPTION OF WORK:
PLUMBING FOR NEW TENANT SPACE
Value of Plumbing /Gas Piping:
Fees Collected:
$25,000.00
$346.00
Plumbing
Bathtub or combination bath/shower
Bidet
Clothes washer, domestic
Dental unit, cuspidor
Dishwasher, domestic, with independent drain
Drinking fountain or water cooler (per head)
Food -waste grinder, commercial
Floor drain
Shower, single head trap
Lavatory
Wash fountain
Receptor, indirect waste
Sinks
Urinals
Water Closet
Uniform Plumbing Code Edition: 2006
International Fuel Gas Code Edition: 2006
FIXTURE TYPE AND QUANTITY
Plumbing (cont.)
0 Building sewer and each trailer park sewer
0 Rain water system - per drain (inside bldg)
0 Water heater and /or vent
0 Industrial waste treatment interceptor, including
0 its trap and vent, except for kitchen type
0 grease interceptors 0
0 Repair or alteration of water piping and/or water
2 treatment equipment 0
0 Repair or alteration of drainage or vent piping 0
2 Medical gas piping system serving (1 -5)
0 inlets /outlets for a specific gas 1
0 Medical gas piping (6 +) inlets /outlets 1
0 Gas Piping
0 Gas piping outlets (0 -5) 0
2 Gas piping outlets (6 +) 0
0
0
1
* *continued on next page **
doc: UPC -10/06
PG08 -086 Printed: 07 -21 -2008
City ofTukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tulcwila.wa.us
Permit Number: PG08 -086
Issue Date: 06/11/2008
Permit Expires On: 12/15/2008
Permit Center Authorized Signature: WA'`" (" Date: .7"..)--1 —0 9
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this pe 't does not > resume o give authority to violate or cancel the provisions of any other state or local laws regulating
construction or . e • - rforman - • ork. , authorized to sign and obtain this plumbing /gas piping permit.
Dater
Signa
Print Name:
e
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: UPC -10/06
PG08 -086 Printed: 07 -21 -2008
Parcel No.:
Address:
Suite No:
CitAf Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
PLUMBING /GAS PIPING PERMIT
6364200010
2876 SOUTHCENTER MALL TUKW
Permit Number:
Issue Date:
Permit Expires On:
PG08 -086
06/11/2008
12/08/2008
Tenant:
Name:
Address:
Owner:
Name:
Address:
Contact Person:
Name:
Address:
WESTFIELD - VANILLA BOX
2876 SOUTHCENTER MALL , TUKWILA WA
WESTFIELD PROPERTY TAX DEPT
PO BOX 130940 , CARLSBAD CA
KEITH SMITH
1725 WESTLAKE AVE N , SEATTLE WA
Contractor:
Name: AMERICAN MECHANICAL CORP
Address: PO BOX 1136 , MONROE WA
Contractor License No: AMERIMC071BH
Phone:
Phone: 206- 713 -4076
Phone: (206)467 -6407
Expiration Date: 01/08/2009
DESCRIPTION OF WORK:
PLUMBING FOR NEW TENANT SPACE
Value of Plumbing /Gas Piping:
Fees Collected:
$25,000.00
$226.00
Plumbing
Bathtub or combination bath/shower
Bidet
Clothes washer, domestic
Dental unit, cuspidor
Dishwasher, domestic, with independent drain
Drinking fountain or water cooler (per head)
Food -waste grinder, commercial
Floor drain
Shower, single head trap
Lavatory
Wash fountain
Receptor, indirect waste
Sinks
Urinals
Water Closet
Uniform Plumbing Code Edition: 2006
International Fuel Gas Code Edition: 2006
FIXTURE TYPE AND OUANTITY
Plumbing (cont.)
0 Building sewer and each trailer park sewer 0
0 Rain water system - per drain (inside bldg) 0
0 Water heater and/or vent 1
0 Industrial waste treatment interceptor, including
0 its trap and vent, except for kitchen type
0 grease interceptors 0
0 Repair or alteration of water piping and/or water
2 treatment equipment 0
0 Repair or alteration of drainage or vent piping 0
2 Medical gas piping system serving (1 -5)
0 inlets /outlets for a specific gas 1
0 Medical gas piping (6 +) inlets /outlets 1
0 Gas Piping
0 Gas piping outlets (0 -5) 0
2 Gas piping outlets (6 +) 0
* *continued on next page **
doc: UPC -10/06
PG08 -086 Printed: 06-11 -2008
City it Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Permit Number: PG08 -086
Issue Date: 06/11/2008
Permit Expires On: 12/08/2008
Permit Center Authorized Signature:
/
Date: Mt0(`Di
I hereby certify that I have read and ex ed this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complies wi , whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or of work. I am authorized to sign and obtain this plumbing /gas piping permit. / p
Date: (Q ^"1/-0 O .-
Signature:
AV/ Print Name: d &)v)-7 Lei CJ
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: UPC -10/06
PG08 -086 Printed: 06 -11 -2008
Parcel No.: 6364200010
Address:
Suite No:
Tenant:
• •
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
PERMIT CONDITIONS
2876 SOUTHCENTER MALL TUKW
BOSS WEAR
Permit Number:
Status:
Applied Date:
Issue Date:
PG08 -086
ISSUED
03/17/2008
06/11/2008
1: ** *PLUMBING AND GAS PIPING * **
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila
Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing
inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas
Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code.
Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to
make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless,
adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the
conditioned space shall be insulated to minimum R -3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be
protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing
piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in
accordance with the requirements of the building code.
11: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the
jurisdiction.
* *continued on next page **
doc: Cond -10/06
PG08 -086 Printed: 07 -21 -2008
• •
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating
construction or the perfo ance of work.
Signature: V� AIL — -
Print Name: /n /' • C�e e
Date: 7 -/ ■4
doc: Cond -10/06
PG08 -086 Printed: 07 -21 -2008
Parcel No.: 6364200010
Address:
Suite No:
Tenant:
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
PERMIT CONDITIONS
2876 SOUTHCENTER MALL TUKW
WESTFIELD - VANILLA BOX
Permit Number:
Status:
Applied Date:
Issue Date:
PG08 -086
ISSUED
03/17/2008
06/11/2008
1: ** *PLUMBING AND GAS PIPING * **
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila
Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing
inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas
Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code.
Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to
make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless,
adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the
conditioned space shall be insulated to minimum R-3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be
protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing
piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in
accordance with the requirements of the building code.
11: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the
jurisdiction.
* *continued on next page **
doc: Cond -10/06
PG08 -086 Printed: 06 -11 -2008
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating
construction or the performance of work.
Signature:
Print Name: 640/d gel it i V
Date: 6-1/-o&'
11 /-o
doc: Cond -10/06
PG08 -086 Printed: 06-11 -2008
Site Address:
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http: / /www. ci. tukwila. wa. us
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
Tenant Name:
Property Owners Name:
Mailing Address:
King C
A1.1
Arrarrawysnroffrr,
f t ii]]��f��'j�� A� _ LL��_%'.r4 —/j
II►L'4 11!%L..�� O r N 1 ii[/�!�„L.�//
Assessor's Tax No.: 1,3 '(2e —ex:/6
Suite Number: 2') 0 Floor: 'W C ,r
New Tenant: Yes ❑..No
City
State
Zip
o weHIcontacttwhentyourpermit;is
Name:
Mailing Address:
E -Mail Address:
I<-.5 (% 4) 17460, air(
Day Telephone: 7e) 6
City
Fax Number:
IENERAL CONTRACTOR INFORMA�'TION �£
outrider Information forrMecbanical (pg 4) for Plumbing =andSGas Piping (pg;5
Company Name:
TO 12
Mailing Address:
City State
Day Telephone:
Fax Number:
Expiration Date:
Contact Person:
E -Mail Address:
Contractor Registration Number:
Zip
FARE`
Al plans nnot
Company Name:
Mailing Address:
Contact Person: 9i'i
6
E -Mail Address: r WI 1, C')
INEEI
City Sae Zip
Day Telephone: 7e.)& (3 407
Fax Number: , 6. 4 4- 69'-1 o()
0
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Q:WpplicationsWorms- Applications On Linel3 -2006 - Permit Application.doe
•� Revised 9 -2006
bh
State
Zip
Page 1 of 6
'Il PER�T INORMA:A 43N
PLUMBING AND GAS PIPING CONTRACTOR INFORMATION
Company Name:
77797 9
Mailing Address:
City State Zip
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
Valuation of Plumbing work (contractor's bid price): $ { r° C S�
Valuation of Gas Piping work (contractor's bid price): $
Scope of Work (please provide detailed information): pre /7/ /71,64- t f - 1-5
Building Use (per Int'l Building Code):
Occupancy (per Int'l Building Code):
Utility Purveyor: Water:
Sewer:
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
,e
�Fature Type.E,,w;, ,....
Qty
�
;.Fi iiiii Type � _.<
,Q ur
i
..F.,�xturc Typei ` ,
M � 0
.,Qty.4
- ks', "'fw
,Fixture Type :;,',
fOiSO
Bathtub or combination
bath/shower
Drinking fountain or water
cooler (per head)
Wash fountain
Gas piping outlets
Bidet
Food -waste grinder,
commercial
Receptor, indirect
waste
Clothes washer, domestic
Floor drain
j-
Sinks
Dental unit, cuspidor
Shower, single head trap
Urinals
Dishwasher, domestic,
with independent drain
Lavatory
Water Closet
Building sewer or trailer
park sewer
Rain water system — per
drain (inside building)
Water heater and/or
vent
I
/
Additional medical gas
inlets/outlets — six or more
Industrial waste
pretreatment interceptor,
including its trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of water
piping and/or water treating
equipment
Repair or alteration
of drainage or vent
piping
Medical gas piping system
serving one to five
inlets/outlets for specific gas
Q:Wpplications\Fonns- Applications On Line\3 -2006 - Permit Application.doc
Revised 9 -2006
bh
Page 5 of 6
NOTES Appl�cabletoll permltsin
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OW
Signature:
Print Name:
R OR AUTHORIZED AGENT:
Mailing Address:
// �,A, Date:
e-AA Day, Telephone:
L 11/C W 5h et a 1\1 City 2U ` 5'
ty State
Date Application Accepted: ,
Date Application Expires:C/
j
p
Staff Initials:
U/it I
Q:kApplicationstFonns- Applications On Linen -2006 - Pertnit Application.doc
Revised 9 -2006
bit
Page 6 of 6
Parcel No.: 6364200010
Address:
Suite No:
Applicant: BOSS WEAR
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http://www.ci.tukwila.wa.us
2876 SOUTHCENTER MALL TUKW
RECEIPT
Permit Number:
Status:
Applied Date:
Issue Date:
PG08 -086
ISSUED
03/17/2008
06/11/2008
Receipt No.: R08 -02671
Initials:
User ID:
Payee:
WER
1655
Payment Amount:
Payment Date:
Balance:
$60.00
07/21/2008 02:40 PM
$0.00
AMC
TRANSACTION LIST:
Type Method
Descriptio Amount
Payment Check
ACCOUNT ITEM LIST:
Description
19535 60.00
Account Code
Current Pmts
PLUMBING - NONRES 000.322.103.00.0
60.00
Total: $60.00
don! RAN int -nR
Printarl: 07- 21 -2nnR
Parcel No.:
Address:
Suite No:
Applicant:
City of Tukwila
Department of Community Deveropment
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
6364200010
2876 SOUTHCENTER MALL TUKW
WESTFIELD - VANILLA BOX
RECEIPT
Permit Number:
Status:
Applied Date:
Issue Date:
PG08 -086
ISSUED
03/17/2008
06/11/2008
Receipt No.: R08 -02236
Initials: WER
User ID: 1655
Payment Amount: $60.00
Payment Date: 06/23/2008 03:08 PM
Balance: $0.00
Payee:
AMC
TRANSACTION LIST:
Type Method Descriptio
Amount
Payment Check 19445
60.00
ACCOUNT ITEM LIST:
Description Account Code
Current Pmts
PLUMBING - NONRES 000.322.103.00.0
60.00
Total: $60.00
doc: Receiot -06
Printed: 06 -23 -2008
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http:/lwww.ci.tukwila.wa.us
SET RECEIPT
RECEIPT NO: R08 -02070
Initials: JEM
User ID: 1165
Payee: AMC
Payment Date: 06/11/2008
Total Payment: 3,404.00
SET ID: 0611
SET TRANSACTIONS:
Set Member Amount
PGO8 -083 164.00
PGO8 -085 164.00
p
G0:8 , 188.00
PG08 -104 164.00
PG08 -105 164.00
PG08 -128 512.00
PG08 -129 512.00
PG08 -130 512.00
PGO8 -131 512.00
PGO8 -132 512.00
TOTAL: 3,404.00
SET NAME: WESTFIELD PLUMBING
TRANSACTION LIST:
Type Method Description Amount
Payment Check 19416 3,404.00
TOTAL: 3,404.00
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
PLAN CHECK - NONRES
PLUMBING - NONRES
000/345.830 1,800.00
000.322.103.00.0 1,604.00
TOTAL: 3,404.00
3538 06/11 9711 TOTAL 3404.00
•
City of Tukwila
• X
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http.• / /www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 6364200010 Permit Number: PG08 -086
Address: 2876 SOUTHCENTER MALL TUKW Status: PENDING
Suite No: Applied Date: 03/17/2008
Applicant: WESTFIELD VACANT SPACE Issue Date:
Receipt No.: R08 -00797
Initials: WER
User ID: 1655
Payment Amount: $38.00
Payment Date: 03/17/2008 03:13 PM
Balance: $188.00
Payee: ERIK BARTH
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 215 38.00
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
PLAN CHECK - NONRES
000/345.830 38.00
Total: $38.00
doc: Receiot -06 Printed: 03 -17 -2008
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -360
Project-
Type of Inspection: ‘.,..
Address:
<2674.. /11,4)-,/
Date Called:
Special Instructions:
Date Wanted:
-7- Z2 - vcc�
Requester:
Phone No
. , = o 3 - 9977
' NiApproved per applicable codes. Corrections required prior to approval.
COMMENTS:
. F i 4 a-1 eGVfri /e. -fig
I.:44.4 f" Zer (Ai etJ
le,"' ,46
tvl
if 1 al, et, by A"
'49/6'
Inspector:
l
Date: 2% z / )
$60.00 INSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid 6'300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
_ . -a_ •..-u - . LL.. - ._,_ ,.Y._I _ ..a
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION R-
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Project:
R o -:ofqsA45 ideteut £ ) a
Type of nspection: i
Address:
ca 3 ?7 17719
//
Date Called:
Special Instructions:
Date Wanted: / e- ve
i..
Requester:
Approved per applicable codes. Corrections required prior too approval.
COMMENTS: �_h
t 9
R o -:ofqsA45 ideteut £ ) a
IN --a_ 0 afc._ -
‘40-11,,, 1 a -mi 4ss- 0 ErE-as.4 (4, e6
t l J Q-"--C-SL- Vi.-(-4`E. (e2 QJ 44
t -'z S .a 0PL -1 .
El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
1
PERMIT COORD copy
PLAN REVIEW/ROUTING SLIP
ACTIVITY NUMBER: PG08 -086
PROJECT NAME: BOSS WEAR
SITE ADDRESS: 2876 SOUTHCENTER MALL
DATE: 7 -14 -08
Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter # X Revision # 2 After Permit Issued
DEPARTMENTS:
Buil: ingP ivision
Public \A/4s 1, goo
Fire Prevention n Planning Division
Structural
Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Incomplete
DUE DATE: 7-17-08
Not Applicable
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROU ING:
Please Route Structural Review Required n No further Review Required n
REVIEWER'S INITIALS: DATE:
APPROVALS R CORRECTIONS:
_u7
Approved Approved with Conditions
Notation:
REVIEWER'S INITIALS:
DUE DATE: 8-14 -08
Not Approved (attach comments) n
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2-28-02
PERMIT COORS COPY «
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: PG08 -086 DATE: 06 -16 -08
PROJECT NAME: WESTFIELD VANILLA BOX
SITE ADDRESS: 2876 SOUTHCENTER MALL
Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter # X Revision # 1 after Permit Issued
DEPARTMENTS:
Bui • b IJIVision
Fire Prevention
Public Works Structural
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
Incomplete
n
Planning Division
n
nPermit Coordinator ❑
DUE DATE: 06-17-08
Not Applicable n
Permit Center Use Only
INCOMPLETE LETTER MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
LETTER OF COMPLETENESS MAILED:
TUES/THURS ROUTING:
Please Route
REVIEWER'S INITIALS:
Structural Review Required No further Review Required
DATE:
APPROVALS R CORRECTIONS:
DUE DATE: 07-155 -08
Approved Approved with Conditions Not Approved (attach comments) n
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
• o
PERMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: PG08 -086
DATE: 03 -18 -08
PROJECT NAME: WESTFIELD VACANT SPACE
SITE ADDRESS: 2876 SOUTHCENTER MALL
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # After Permit Issued
DEPARTMENTS:
Bui .f g ' ivlsion
Pf�li�c Wore toe Structural
Fire Prevention
Planning Division
❑ Permit Coordinator
n
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 03 -20-08
Complete
Comments:
Incomplete
n
Not Applicable
Permit Center Use Only
INCOMPLETE LETTER MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
LETTER OF COMPLETENESS MAILED:
TUES/THURS ROUTING:
Please Route
Structural Review Required
REVIEWER'S INITIALS:
No further Review Required
DATE:
APPROVALS OR CORRECTIONS:
Approved
Notation:
Approved with Conditions
DUE DATE: 04 -17 -08
Not Approved (attach comments) n
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
PROJECT NAME: I
SITE ADDRESS: %II, Gjo &&KlA-
PERMIT NO: P(;'7 p
ORIGINAL ISSUE DATE: apl Gt t
REVISION LOG
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
STAFF
INITIALS
1
OifllULOS
"lL
(¢-', -3-Or
Summary of Revision:
`'Wf
Summary of Revision: -jib -hN of 1211/C-1- er7oWt. -. 0 w
re.
I.r iv-AC PINVOAC
Received by: /�
/l/!
Received by:�--
,, ,__J >,----r____
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
STAFF
INITIALS
2—
-7 - 0-1 - or
"lL
-7' I I -0 e
Summary of Revision:
Received by:
Summary of Revision: C(n, Int i..a "\-�
re.
Received by: /�
/l/!
460-79•&:.-
(please print)
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
Summary of Revision:
Received by:
(please print)
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
Summary of Revision:
Received by:
(please print)
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
Summary of Revision:
Received by:
(please print)
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
Summary of Revision:
Received by:
(nlPace nrintl
City of Tukwila
Steven Al. Mullet, Mayor
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http. /hvww.ci.tukwila.wa.us
Steve Lancaster, Director
Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through
the mail, fax, etc.
Date:
7//
Plan Check/Permit Number: Pa S 84.
❑ Response to Incomplete Letter #
❑ Response to Correction. Letter #
— Revision # 2_ after Permit is Issued
❑ Revision requested by a City Building Inspector or Plans Examiner
Project Name: /gp55 VI/e Y C rncr /7 Wes1--.4'e /4 VQnilli eox)
rkiek !1
Project Address: o b%f VO u 7 h C e--+
Contact Person: P i cdorsQ Phone Number: S/ s- -- 4/0.2x- 892.3
Summary of Revision:
eli rr_4 a V 4.4n /14 re.4 -. _.,. f n a tP-1 e
/ e : IfeAtd e%14,'
- Ciec.a,55Urr es
ad 2-k
:` /!
V J
� / 14 ea Se.
VitCEIVED
:LIP( OF TUKWILA
Sheet Number(s):
JUL 14 2008
"Cloud" or highlight all areas of revision including date of revisi
Received at the City of Tukwila Permit Center by:
— Entered in Permits Plus on 71:'° t Lt4-6
lapplicationslforms- applications en linelrevision submittal
Created: 8 -13 -2004
-.._ QENTER
•
City of Tukwila
Steven M. Mullet, Mayor
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206-431-3665
Web site: http : //www.ci. tukwila. wa. us
Steve Lancaster, Director
Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through
the mail, fax, etc.
Date:
e/ /4.D 8'
❑ Response to Incomplete Letter #
❑ Response to Correction Letter #
[c� Revision # / after Permit is Issued
❑ Revision requested by a City Building Inspector or Plans Examiner
Project Name: vU es'( c/ je / V11; / /l- 8 x
Project Address: a8 7 561i e �, > /9"' /1
Contact Person: , 2e-c -r'a _R.dd/ u -.L Phone Number: ova -- bi02- 6,67/
Summary of Revision: _
//e-i1%6 Pk/J/-2 / �` 1/-7/ 74 Ye�/ de/ 7`io-,-1 a�-
4� e_ 76'7 room
ifei/ ;5e_ G4,46k.
740 re /ee eie/C /LI o>1 Z5231-242 /�>L
Plan Check/Permit Number:
RECEIVED
CITY OF 71J t.A
JUN 16 2008
PERMIT CENTER
Sheet Number(s): P /
"Cloud" or highlight all areas of revision including date of revision
Received at the City of Tukwila Permit Center by:
Entered in Permits Plus on
(applicationslforms- applications on linetrevision submittal
Created: 8 -13 -2004
Look Up a Contractor, Electroan or Plumber License Detail
Washington State Department of Labor and Industries
GeneraUSpecialty Contractor
A business registered as a construction contractor with L &I to perform
construction work within the scope of its specialty. A General or Specialty
construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
License Information
License
AMERIMC071BH
Licensee Name
AMERICAN MECHANICAL CORP
Licensee Type
CONSTRUCTION CONTRACTOR
UBI
601433818
Ind. Ins. Account Id
53821001
Business Type
CORPORATION
Address 1
PO BOX 1136
Address 2
City
MONROE
County
SNOHOMISH
State
WA
Zip
982724136
Phone
2064676407
Status
ACTIVE
Specialty 1
BOILER/STEAM FIT/PROC PIPING
Specialty 2
PLUMBING
Effective Date
1/8/1993
Expiration Date
1/8/2009
Suspend Date
Separation Date
Parent Company
Previous License
Next License
Associated License
Business Owner Information
Name
Role
Effective Date
Expiration Date
KING, CHERI L
PRESIDENT
01/08/1993
KING, KELLY E
TREASURER
01/08/1993
0
Bond Information
Bond
Bond
Company
Name
Bond
Account
Number
Effective
Date
Expiration
Date
Cancel
Date
Impaired
Date
Bond
Amount
Received
Date
OLD
REPUBLIC
SURETY
Until
Page 1 of 2
https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= AMERIMC071 BH 06/11/2008
PLUMBING FIXTURE SCHEDULE
PLAN MARK
MANUFACTURER
MODEL NUMBER
NOTES
WC
AMERICAN STANDARD
#2168.100
C/W SUPPLY PIPING, ANGLE VALVE, WALL FLANGE AND FLEXIBLE RISER. (ZURN ZH- 8825- CR -LK) SEAT OLSONITE #46SSTL
LAV
ADVANCE
7 -PS -50
STAINLESS STEEL SINK, LEVER OPERATED DRAIN K -26, S.S. BASKET K -6, ADVANCE FAUCET K -9,
WH
A.O. SMITH
ELJF -10
1- 0-G.A. STORAGE CAPACITY, 3.0 INPUT, 208V. ELECTRIC WATER HEATER
ED
ZURN
ZN- 415 -6S
CAST WITH DEEP SEAL TRAP AND 6" STRAINER
TP
PPP INC.
#PR -500
FULLY AUTOMATIC, ALL BRASS TRAP PRIMER VALVE, ACTIVATED BY A DROP IN BUILDING WATER PRESSURE, NO AJUSTMENT REQUIRED,
MODEL PRIME -RITE FOR 1 TO 4 TRAPS WITH DISTRIBUTION UNIT. MUST BE INSTALLED ON A FRESH COLD WATER LINE OF 1 1/2"
DIAMETER OR LESS, AS INDICATED ON DRAWINGS, OR REQUIRED BY PLUMBING CODE.
WCO
ZURN
--
WALL CLEAN OUT -CAST IRON CLEAN OUT TEE WITH BRONZE THREADED CLEAN OUT PLUG. PLUG TO BE GAS AND WATER TIGHT. WALL
ACCESS PANEL - ZURN #ZANB- 1460 -9 9 "x9" WALL ACCESS PANEL AND FRAME: SMOOTH NICKEL BRONZE SECURING LUGS.
GENERAL PLUMBING NOTES
1. ALL PLUMBING INSTALLATIONS SHALL COMPLY WITH STATE AND LOCAL CODES.
2. PLUMBING CONTRACTOR SHALL MAKE CORRECTIONS IF WATER SUPPLY AND DRAINAGE FOR THE
BUILDING ARE REVERSED.
3. INSTALL ALL THREADED CLEANOUT PLUGS WITH PIPE DOPE TO ALLOW EASY REMOVAL IN THE
FUTURE.
4. IT WILL BE THE RESPONSIBILITY OF THE PLUMBING CONTRACTOR TO INSURE THAT ITEMS TO BE
FURNISHED UNDER PLUMBING CONTRACT WILL FIT THE SPACE AVAILABLE - PLUMBING CONTRACTOR
SHALL MAKE NECESSARY FIELD MEASUREMENTS TO ASCERTAIN SPACE REQUIREMENTS, INCLUDING
THOSE FOR CONNECTIONS AND SHALL FURNISH AND INSTALL SUCH SIZES AND SHAPES OF
EQUIPMENT THAT ARE THE TRUE INTENT OF THE DRAWINGS AND SPECIFICATIONS.
5. GENERAL CONTRACTOR SHALL PROVIDE ALL OPENINGS IN WALLS, FLOORS, AND ROOF WITH
EACH CONTRACTOR RESPONSIBLE FOR VERIFYING LOCATION AND SIZES OF ALL OPENINGS
REQUIRED UNDER HIS CONTRACT, UNLESS NOTED OTHERWISE ON THE PLANS.
6. PLUMBING CONTRACTOR SHALL PROVIDE PRESSURE REDUCING VALVE, SWEAT TYPE, 30 -60 PSIG
DISCHARGE RANGE WHERE REQUIRED BY LOCAL CODES.
7. ALL PLUMBING FIXTURES SHALL BE NEATLY CAULKED WITH SILICONE COMPOUND WHERE FIXTURE
MEETS WALL.
8. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ELECTRICAL AND CONTROL
CONNECTIONS TO PLUMBING EQUIPMENT WITH THE ELECTRICAL CONTRACTOR. SEE PLANS FOR
LOCATIONS OF JUNCTION BOXES, DISCONNECTS, AND CIRCUIT BREAKERS (PANEL BOARDS). TYPE,
SIZE AND NUMBER OF CONDUCTORS AND CONDUITS TO EQUIPMENT SHALL BE COORDINATED WITH &
VERIFIED BY THE ELECTRICAL CONTRACTOR. IN CASE OF PLUMBING EQUIPMENT CONNECTION TO A
CIRCUIT BREAKER, THE NUMBER AND SIZE OF CONDUCTORS AND CONDUIT SHALL CONFORM TO THE
LATEST NATIONAL ELECTRICAL CODE REGULATIONS. ALL MOTOR STARTERS, SWITCHES, CONTROL
DEVICES, ETC., PROVIDED BY THIS CONTRACTOR SHALL BE RECESSED IN THE WALLS, EXCEPT WHERE
THESE ITEMS ARE LOCATED IN MECHANICAL ROOMS. PROVIDE NAMEPLATES FOR ALL EQUIPMENT,
SWITCHES, CONTROL DEVICES, ETC.
9. PLUMBING CONTRACTOR SHALL SUPPLY AND INSTALL GAS PIPING IF SHOWN ON PLANS. ALL GAS
PIPING SHALL COMPLY WITH LOCAL CODES. PLUMBING CONTRACTOR SHALL MAKE FINAL
CONNECTIONS TO ALL EQUIPMENT. INSTALL REGULATORS AT EQUIPMENT WHERE REQUIRED BY
MANUFACTURER OR CUTS SUPPLIED BY FURNISHING CONTRACTOR.
10. PLUMBING CONTRACTOR SHALL INSTALL SHOCK ABSORBERS AT PLACES INDICATED ON THE
PLANS AND RISER DIAGRAM. SHOCK ABSORBERS SHALL BE PDI APPROVED.
11. ALL UNDERGROUND DRAINAGE, WASTE AND VENT PIPE SHALL BE CAST IRON OR PVC AS
ALLOWED BY LOCAL CODES. ALL ABOVE GROUND DRAINAGE, WASTE AND VENT PIPE SHALL BE PVC.
12. CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR APPROVED FLOOR PLAN AND
DIMENSIONS. DO NOT SCALE PLUMBING DRAWINGS.
13. CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING CONDENSATE DRAIN PIPING ON AIR
HANDLING UNITS. COORDINATE WORK WITH MECHANICAL CONTRACTOR.
14. CONTRACTOR SHALL INSTALL WATER PIPING SO THAT PIPE JOINTS ARE NOT UNDER FLOOR
SLAB.
15. PIPE INSULATION SHALL BE CONTINUOUS THROUGH WALLS OR FLOOR.
16. CONTRACTOR SHALL TEST SOIL, WASTE AND VENT SYSTEMS WITH PEPPERMINT. ALL MECHANICAL
SYSTEMS SHALL BE RUNNING WHILE THESE TESTS ARE BEING MADE.
CONTRACTOR SHALL FURNISH A CERTIFICATE OF COMPLIANCE AND ACCEPTANCE OF
THESE TESTS.
17. CONTRACTOR SHALL INSULATE ALL UNDER SLAB HOT WATER PIPING WITH 1" RIGID URETHANE
FOAM INSULATION AND 1" CLOSED CELL RUBBER INSULATION, WITH FIRE RETARDANT COATING ON
ALL HOT WATER AND RETURNS LINES ABOVE SLAB. INSULATE ALL COLD WATER LINES ABOVE SLAB
WITH 1/2" CLOSED CELL RUBBER FIRE RETARDANT INSULATION.
18. ANY DEVIATIONS FROM SPECIFIED PLUMBING FIXTURES AND TRIM IN FIXTURE SCHEDULE SHALL
BE APPROVED PRIOR TO SUBMITTAL FROM THE ALDO'S PROJECT MANAGER.
19. ALL INDIRECT WASTE LINES SHALL HAVE A MINIMUM OF 2" VERTICAL AIR GAP AT FLOOR SINK,
DRAIN OR HUB. FLOOR SINKS, DRAINS OR HUBS SHALL EXTEND A MINIMUM 1" ABOVE FINISHED
FLOOR WHEN SERVING INDIRECT DRAINS.
20. VACUUM BREAKERS SHALL BE INSTALLED ON ALL HOSE BIBBS AND HYDRANTS. VACUUM
BREAKERS /BACK FLOW PREVENTORS TO BE INSTALLED AT ANY POINT WHERE THERE IS DANGER OF
THE NON POTABLE WATER SYSTEM COMING IN CONTACT WITH THE PORTABLE WATER SYSTEM OR
ANY DANGER OF BACK FLOW. COORDINATE WITH LOCAL INSPECTOR.
21. ALL PLUMBING WORK SHALL BE COORDINATED WITH OTHER PROJECT CONTRACTORS BEFORE
INSTALLATION.
22. USE TYPE "K" SOFT DRAWN COPPER UNDER SLAB.
23. ALL WATER DISTRIBUTION PIPE ABOVE GROUND SHALL BE COPPER OR COPPER ALLOY TUBING.
VACUUM RELIEF VAVLE (VALVE
AND TEE ABOVE WATER HEATER)
TACO CX -15 EXPANSION TANK,
FDA AND ASME APPROVED
FOR POTABLE WATER.
•
TO TRAP PRIMER
CONNECTION AT FD
LAV
PROVIDE BALL VALVE. . ig (t teip.: 7
ON
10 GALLON WATER HEATER ABOVE
TOILET CEILING. PROVIDE 3"
DEEP GALV PAN W /SOLDERED
SEAMS.
TERMINATE INDIRECTLY
INTO FLOOR DRAIN
ROUTE AUX. DRAIN TO APPROVED
RECEPTOR SUCH AS TATTLETAIL DRAIN
ETC. WATER HEATER T & P AND DRAIN
PAN CANNOT CAUSE TRIPPING HAZARD.
VERIFY EXACT LOCATION IN FIELD.
C2 1 WATER RISER DIAGRAM
EXTEND NEW 4'\ 5S TO EXISTING
SYSTEM, VERIFY EXACT LOCATION,
FLOW AND DEPTIA.
3"
3" FD
W /TRAP
PRIMER
PROVIDE AND INSTALL
4" V.T.R.
EXTEND NEW 4" SS TO EXISTING
SYSTEM, VERIFY EXACT LOCATION,
FLOW AND DEPTH.
PLUMBING PLAN
WASTE RISER DIAGRAM
Permit No
FILE COPY
pia- revlvw approval is subject to errors and CMISSIons.
Approval of construction documents does not authorize
the violation of any ado.. • - ,:} a or owe. wept
o' approve Id
Y� i� L1•
Date:
City of Tukw a
EJ! DING Erfi V N
R VlbW :D 1 CODE COMPLIANCE
A PPROVED
1 1
JU 1 9 008
Of Tukwila
BUILDING DIVISION
2876 Southcenter Mall
Tukwila, WA 98188
smith Co.
318 terry avenue n
seattle, washington 98109
206.838.5485 p
206.713.4076 m
206.464.0700 f
ksmith @smithco.org
http://www.smithco.org/
Consultant
Consultant Registration
r . __-
No ch RE _ -.._.
anpes shall rr,ad t th
of work without }
Tukwila guildinQr approval
+ o
DrE: revisions 9 Division.
will require a new ( Issues and,Revisions
and may include additional plan .,.�.,.: �l
pan reviev , ` Date
2 03.26.08
3 04.07.08
4 05.05.08
5 05.30.08
RECEIVED
CITY OF TUKWILA
JUN 1 6 2008
PERMIT CENTER
Project Name
Scale AS NOTED
Template
P -1
Issues
ISSUE
6294
PERMIT
BLDG. COMMENTS
PER OT CORR.
OWNER REVISIONS
�® �
Project Number 02008019.00
Description PLUMBING PLAN
Computer File CW05- 2008— P1,DWG
Architect Registration
WESTFIELD °SOUTHCENTER MALL
By Check
KLS
KLS
KLS
KLS
KLS
All ideas, designs, arrangements, and plans indicated or
represented by this drawing are owned by and the property of
smith co. Ilc and were created, evolved, and developed
for use on and in connection with the specified project. None of
such ideas, designs, arrangements or plans shall be used
by or disclosed to any person, firm, or corporation for any
purpose whatsoever without the written permission of smith co. Ilc.
PLUVBING FIXTURE SCHEDULE
PLAN MARK
MANUFACTURER
MODEL NUMBER
NOTES
WC
AMERICAN STANDARD
#2168.100
C/W SUPPLY PIPING, ANGLE VALVE, WALL FLANGE AND FLEXIBLE RISER. (ZURN 2H- 8825- CR -LK) SEAT OLSONITE #4655TL
LAV
ADVANCE
7 -PS -50
STAINLESS STEEL SINK, LEVER OPERATED DRAIN K -26, S.S. BASKET K -6, ADVANCE FAUCET K -9,
WH
A.O. SMITH
ELJF -10
1.0 -G.A. STORAGE CAPACITY, 3.0 INPUT, 208V. ELECTRIC WATER HEATER
ED
ZURN
ZN- 415 -6S
CAST WITH DEEP SEAL TRAP AND 6" STRAINER
TP
PPP INC.
#PR -500
FULLY AUTOMATIC, ALL BRASS TRAP PRIMER VALVE, ACTIVATED BY A DROP IN BUILDING WATER PRESSURE, NO AJUSTMENT REQUIRED,
MODEL PRIME -RITE FOR 1 TO 4 TRAPS WITH DISTRIBUTION UNIT. MUST BE INSTALLED ON A FRESH COLD WATER LINE OF 1 1/2"
DIAMETER OR LESS, AS INDICATED ON DRAWINGS, OR REQUIRED BY PLUMBING CODE.
WCO
ZURN
--
WALL CLEAN OUT -CAST IRON CLEAN OUT TEE WITH BRONZE THREADED CLEAN OUT PLUG. PLUG TO BE GAS AND WATER TIGHT. WALL
ACCESS PANEL - ZURN #ZANB- 1460 -9 9 "x9" WALL ACCESS PANEL AND FRAME: SMOOTH NICKEL BRONZE SECURING LUGS.
GENERAL PLUv1BI\
G NOTES
1. ALL PLUMBING INSTALLATIONS SHALL COMPLY WITH STATE AND LOCAL CODES.
2. PLUMBING CONTRACTOR SHALL MAKE CORRECTIONS IF WATER SUPPLY AND DRAINAGE FOR THE
BUILDING ARE REVERSED.
3. INSTALL ALL THREADED CLEANOUT PLUGS WITH PIPE DOPE TO ALLOW EASY REMOVAL IN THE
FUTURE.
4. IT WILL BE THE RESPONSIBILITY OF THE PLUMBING CONTRACTOR TO INSURE THAT ITEMS TO BE
FURNISHED UNDER PLUMBING CONTRACT WILL FIT THE SPACE AVAILABLE - PLUMBING CONTRACTOR
SHALL MAKE NECESSARY FIELD MEASUREMENTS TO ASCERTAIN SPACE REQUIREMENTS, INCLUDING
THOSE FOR CONNECTIONS AND SHALL FURNISH AND INSTALL SUCH SIZES AND SHAPES OF
EQUIPMENT THAT ARE THE TRUE INTENT OF THE DRAWINGS AND SPECIFICATIONS.
5. GENERAL CONTRACTOR SHALL PROVIDE ALL OPENINGS IN WALLS, FLOORS, AND ROOF WITH
EACH CONTRACTOR RESPONSIBLE FOR VERIFYING LOCATION AND SIZES OF ALL OPENINGS
REQUIRED UNDER HIS CONTRACT, UNLESS NOTED OTHERWISE ON THE PLANS.
6. PLUMBING CONTRACTOR SHALL PROVIDE PRESSURE REDUCING VALVE, SWEAT TYPE, 30 -60 PSIG
DISCHARGE RANGE WHERE REQUIRED BY LOCAL CODES.
7. AL PLUMBING FIXTURES SHALL BE NEATLY CAULKED WITH SILICONE COMPOUND WHERE FIXTURE
MEETS WALL.
8. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ELECTRICAL AND CONTROL
CONNECTIONS TO PLUMBING EQUIPMENT WITH THE ELECTRICAL CONTRACTOR. SEE PLANS FOR
LOCATIONS OF JUNCTION BOXES, DISCONNECTS, AND CIRCUIT BREAKERS (PANEL BOARDS). TYPE,
SIZE AND NUMBER OF CONDUCTORS AND CONDUITS TO EQUIPMENT SHALL BE COORDINATED WITH &
VERIFIED BY THE ELECTRICAL CONTRACTOR. IN CASE OF PLUMBING EQUIPMENT CONNECTION TO A
CIRCUIT BREAKER, THE NUMBER AND SIZE OF CONDUCTORS AND CONDUIT SHALL CONFORM TO THE
LATEST NATIONAL ELECTRICAL CODE REGULATIONS. ALL MOTOR STARTERS, SWITCHES, CONTROL
DEVICES, ETC., PROVIDED BY THIS CONTRACTOR SHALL BE RECESSED IN THE WALLS, EXCEPT WHERE
THESE ITEMS ARE LOCATED IN MECHANICAL ROOMS. PROVIDE NAMEPLATES FOR ALL EQUIPMENT,
SWITCHES, CONTROL DEVICES, ETC.
9. PLUMBING CONTRACTOR SHALL SUPPLY AND INSTALL GAS PIPING IF SHOWN ON PLANS. ALL GAS
PIPING SHALL COMPLY WITH LOCAL CODES. PLUMBING CONTRACTOR SHALL MAKE FINAL
CONNECTIONS TO ALL EQUIPMENT. INSTALL REGULATORS AT EQUIPMENT WHERE REQUIRED BY
MANUFACTURER OR CUTS SUPPLED BY FURNISHING CONTRACTOR.
10. PLUMBING CONTRACTOR SHALL INSTALL SHOCK ABSORBERS AT PLACES INDICATED ON THE
PLANS AND RISER DIAGRAM. SHOCK ABSORBERS SHALL BE PDI APPROVED.
11. ALL UNDERGROUND DRAINAGE, WASTE AND VENT PIPE SHALL BE CAST IRON OR PVC AS
ALLOWED BY LOCAL CODES. ALL ABOVE GROUND DRAINAGE, WASTE AND VENT PIPE SHALL BE PVC.
12. CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR APPROVED FLOOR PLAN AND
DIMENSIONS. DO NOT SCALE PLUMBING DRAWINGS.
13. CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING CONDENSATE DRAIN PIPING ON AIR
HANDLING UNITS. COORDINATE WORK WITH MECHANICAL CONTRACTOR.
14. CONTRACTOR SHALL INSTALL WATER PIPING SO THAT PIPE JOINTS ARE NOT UNDER FLOOR
SLAB.
15. PIPE INSULATION SHALL BE CONTINUOUS THROUGH WALLS OR FLOOR.
16. CONTRACTOR SHALL TEST SOIL, WASTE AND VENT SYSTEMS WITH PEPPERMINT. ALL MECHANICAL
SYSTEMS SHALL BE RUNNING WHILE THESE TESTS ARE BEING MADE.
CONTRACTOR SHALL FURNISH A CERTIFICATE OF COMPLIANCE AND ACCEPTANCE OF
THESE TESTS.
17. CONTRACTOR SHALL INSULATE ALL UNDER SLAB HOT WATER PIPING WITH 1" RIGID URETHANE
FOAM INSULATION AND 1" CLOSED CELL RUBBER INSULATION, WITH FIRE RETARDANT COATING ON
ALL HOT WATER AND RETURNS LINES ABOVE SLAB. INSULATE ALL COLD WATER LINES ABOVE SLAB
WITH 1/2" CLOSED CELL RUBBER FIRE RETARDANT INSULATION.
18. ANY DEVIATIONS FROM SPECIFIED PLUMBING FIXTURES AND TRIM IN FIXTURE SCHEDULE SHALL
BE APPROVED PRIOR TO SUBMITTAL FROM THE ALDO'S PROJECT MANAGER.
19. ALL INDIRECT WASTE LINES SHALL HAVE A MINIMUM OF 2" VERTICAL AIR GAP AT FLOOR SINK,
DRAIN OR HUB. FLOOR SINKS, DRAINS OR HUBS SHALL EXTEND A MINIMUM 1" ABOVE FINISHED
FLOOR WHEN SERVING INDIRECT DRAINS.
20. VACUUM BREAKERS SHALL BE INSTALLED ON ALL HOSE BIBBS AND HYDRANTS. VACUUM
BREAKERS /BACK FLOW PREVENTORS TO BE INSTALLED AT ANY POINT WHERE THERE IS DANGER OF
THE NON POTABLE WATER SYSTEM COMING IN CONTACT WITH THE PORTABLE WATER SYSTEM OR
ANY DANGER OF BACK FLOW. COORDINATE WITH LOCAL INSPECTOR.
21. ALL PLUMBING WORK SHALL BE COORDINATED WITH OTHER PROJECT CONTRACTORS BEFORE
INSTALLATION.
22. USE TYPE "K" SOFT DRAWN COPPER UNDER SLAB.
23. ALL WATER DISTRIBUTION PIPE ABOVE GROUND SHALL BE COPPER OR COPPER ALLOY TUBING.
VACUUM RELIEF VAVLE (VALVE
AND TEE ABOVE WATER HEATER)
TACO CX -15 EXPANSION TANK,
FDA AND ASME APPROVED
FOR POTABLE WATER.
SCALE: N.T.S.
wC
TO TRAP PRIMER
CONNECTION AT FD
ED
PROVIDE BALL VALVE.
-UNION
LAV
WATER RISER DIAGRAM
10 GALLON WATER HEATER ABOVE
TOILET CEILING. PROVIDE 3"
DEEP GALV PAN W /SOLDERED
SEAMS.
TERMINATE INDIRECTLY
INTO FLOOR DRAIN
ROUTE AUX. DRAIN TO APPROVED
RECEPTOR SUCH AS TATTLETAIL DRAIN
ETC. WATER HEATER T & P AND DRAIN
PAN CANNOT CAUSE TRIPPING HAZARD.
VERIFY EXACT LOCATION IN FIELD.
wC
TO TRAP PRIMER
CONNECTION AT FD
LAV
ovp
EXTEND NEW 4" 55 TO EXISTING
SYSTEM, VERIFY EXACT LOCATION,
FLOW AND DEPTH.
K
> I
› I
y
1
WC I
3" FD
W /TRAP
PRIMER
3"
•
•
•
•
•
F A
W
' ......
WC
FD
FD
}
ii
I� PROVIDE AND INSTALL
4" V.T.R.
SCALE: N.T.S.
WC
3" FD
W /TRAP
PRIMER
PLUMBING PLAN
SCALE: 1/4" = 1'--0"
f i i f aii i iii i i 1 r
71
3"
LAV y H
N I
LAV
WCO
WASTE RISER DIAGRAM
EXTEND NEW 4" SS TO EXISTING
SYSTEM, VERIFY EXACT LOCATION,
FLOW AND DEPTH.
; iii��ii ii
By
Date:
REVIEWED FOR
CODE COMPLIANCE
AP ,O fir
MAR
y Of Tukwj,1l
BUILDING DIVISION
ALE COPY
Permit No.
Plar review approval is subject to arms and omens.
construction of nst u�on documents does not autbatte
the violation of any adopted code or ordnance. Receipt
of approved Fie! and ... Mons is acknowledged:
City of Tukwila
BUILDING DIVISION
1;t isioNS
No changes shill be to thn s ^ ^n^
of work without prior apprnvnl �r
Tukwila Building Division
NOTE: Revisions will require a new r 12n
and may include additional plan
l SEPARATE PERU I
REQUIRED R:
i MCCsi fl!C :I
L°1 Electrical
0 Plumbing
❑ Gas Piping
City of ► ukwii
MAR 17 2008
?&o8 08&
2876 Southcenter Mall
Tukwila, WA 98188
smith
318 terry avenue n
seattle, washington 98109
206.838.5485 p
206.713.4076 m
206.464.0700 f
ksmith @smithco.org
http: / /www.smithco.org/
Consultant
Consultant Registration
1
Issues and Revisions
No. Date
1 02.08.08
Project Number 02008018.00
6294
Project Name WESTFIELD SOUTHCENTER MALL
Description PLUMBING PLAN
Computer File CW05- 2008— P1.DWG
Scale AS NOTED
Template 4.3 (120101)
P -1
REGISTERED
ARCI - i ECT
D .I
STATE OF WASHINGTON
Architect Registration
Issues By Check
PERMIT KLS
All ideas, designs, arrangements, and plans indicated or
represented by this drawing are owned by and the property of
smith co. Ilc and were created, evolved, and developed
for use on and in connection with the specified project. None of
such ideas, designs, arrangements or plans shall be used
by or disclosed to any person, firm, or corporation for any
purpose whatsoever without the written permission of smith co. Ilc.