Loading...
HomeMy WebLinkAboutPermit PG08-092 - AT&T MOBILITYAT &T MOBIUTY 16425 SOUTHCENTER PY PGO8-092 Parcel No.: Address: Suite No: CitAf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PLUMBING /GAS PIPING PERMIT 5379200290 16425 SOUTHCENTER PY TUKW Permit Number: Issue Date: Permit Expires On: PG08 -092 05/13/2008 11/09/2008 Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: AT &T MOBILITY 16425 SOUTHCENTER MALL , TUKWILA WA ARGUS GROUP LTD C/O METROVATION , 225 108TH AVE NE #520 SAMSON HU 4 HUTTON CENTER DR STE 800 , SANTA ANA CA C B BOVENKAMP 9002 SW 152ND ST , MIAMI FL Contractor License No: CBBOVI *006D8 Phone: Phone: 714- 327 -4203 Phone: Expiration Date: 08/30/2009 DESCRIPTION OF WORK: INSTALL TWO NEW RESTROOMS Value of Plumbing /Gas Piping: Fees Collected: $15,000.00 $226.00 Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 FIXTURE TYPE AND QUANTITY Plumbing (cont.) 0 Building sewer and each trailer park sewer 0 0 Rain water system - per drain (inside bldg) 0 0 Water heater and/or vent 1 0 Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 1 grease interceptors 0 0 Repair or alteration of water piping and/or water 0 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 2 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 1 0 Medical gas piping (6 +) inlets /outlets 1 1 Gas Piping 0 Gas piping outlets (0 -5) 0 2 Gas piping outlets (6 +) 0 * *continued on next page ** doc: UPC -10/06 PG08 -092 Printed: 05 -13 -2008 City ot Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: htql://www.ci.tukwila.wa.us Permit Number: PG08 -092 Issue Date: 05/13/2008 Permit Expires On: 11/09/2008 Permit Center Authorized Signature: Date: 611,31,z I hereby certify that I have read and e : - ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied , whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or t erformance yf work. J9am authorized to sign and obtain this plumbing /gas piping permit. Signature: Print Name: k2 L J C1' 0114/2-5 Date: /3 Dg This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -10/06 PG08 -092 Printed: 05-13 -2008 Parcel No.: 5379200290 Address: Suite No: Tenant: • 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16425 SOUTHCENTER PY TUKW AT &T MOBILITY PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: PG08 -092 ISSUED 03/21/2008 05/13/2008 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. * *continued on next page ** doc: Cond -10/06 PG08 -092 Printed: 05 -13 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: 4 fOs -,-G 0/0,14 /35 Date: /3-t08 doc: Cond -10/06 PG08 -092 Printed: 05-13 -2008 CITY OF TUKWIL Community De velopmen.department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Plurnbing/G Permit No. -V63 `L�CI.� Project No (For office use only, PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: Site Address: t /' 4� 5 �j 1 T� G-V-N1V2, r i IA/A Y Suite Number: Tenant Name: AT 8 T. Property Owners Name: $ M /V 4 L r( 17-0 - t,t -r kt2- , k-c Mailing Address: Floor: New Tenant: [5.... Yes ❑ ..No City State Zip CONTACT PERSON —Who do hen, your permit is ready to b Name: 4 M 'fN H1A . Day Telephone: —74 7j2 7 4--ZO �?? Mailing Address: (-{-t (TTT ZW1 f7i21 vt gam% .,a , w, (4 . 1;7 City State p E -Mail Address: Fax Number: 7/4 •? 1 PLI M S PIP NG CON'T'RACTOR INFOI Company Name: T7 t2 Mailing Address: City Day Telephone: Fax Number: Expiration Date: Contact Person: E -Mail Address: Contractor Registration Number: Company Name: t-1-0.-1-1M4 f� Mailing Address: 4 Gof 170 V.� Q- PU e -4t i. A if 41 0 • 17,70, City State zip Contact Person: Day Telephone: 714 i 7 E -Mail Address: Fax Number: r State Zip Company Name: _ �1 Mailing Address: 4 4-kirj" rn\I i t Vt 4rV 0 AIA • 1; %/% City State `Lip Contact Person: Day Telephone: E -Mail Address: Fax Number: + tip LiG7• Q:\Applications\Forms- Applications On Line \3 -2006 - Plumbing -Gas Piping Permit Application.doc Revised: 4 -2006 bh Page 1 of 2 Valuation of Project (contractor's bid price): $ 7 to 1, Scope of Work (please provide detailed information): , kJ 4f A i (. -fj / Building Use (per Intl Building Code): 1 C-`'j'jv tt 43:14 1 L Occupancy (per Int'l Building Code): Nl _ nit v_12..eA 1.1 Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain Sinks J Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Z. Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and /or vent Additional medical gas inlets /outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and /or water treating equipment Repair or alteration of drainage or vent piping I Medical gas piping system serving one to five inlets /outlets for specific gas PERMIT APPLICATION A Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN OR 60,00 UTHO RIIIZEDAGENT: Print Name: 4,i, V M . Signature: Mailing Address: Date: 7tt Day Telephone: City State Zip Date Application Accepted: .S--€?` 1 - Date Application Expires: 9--)-( -U E/ Staff Initials: Q:Wpplications\Forms- Applications On Line'3 -2006 - Plumbing -Gas Piping Permit Application doc Revised. 4 -2006 bh Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http../Iwww.ci.tukwila.wa.us SET RECEIPT RECEIPT NO: R08 -01579 Initials: WER User ID: 1655 Payee: CB BOVENKAMP, INC. Payment Date: 05/13/2008 Total Payment: 1,515.50 SET ID: 0513 SET NAME: AT &T MOBILITY SET TRANSACTIONS: Set Member Amount D08 -149 1,056.50 M08 -087 271.00 PG078:50794 188.00 TOTAL: 1,515.50 TRANSACTION LIST: Type Method Description Amount Payment Check 42109 ACCOUNT ITEM LIST: Description TOTAL: 1,515.50 1,515.50 Account Code Current Pmts BUILDING - NONRES MECHANICAL - NONRES PLUMBING - NONRES STATE BUILDING SURCHARGE 000/322.100 1,052.00 000.322.102.00.0 271.00 000.322.103.00.0 188.00 000/386.904 4.50 TOTAL: 1,515.50 2339 05/13 9711 TOTAL 1515°50 Doc: RECSETS -06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 5379200290 Permit Number: PG08 -092 Address: 16425 SOUTRCENTER PY TUKW Status: PENDING Suite No: Applied Date: 03/21/2008 Applicant: AT &T MOBILITY Issue Date: Receipt No.: R08 -00978 Payment Amount: $38.00 Initials: WER Payment Date: 03/31/2008 09:48 AM User ID: 1655 Balance: $188.00 Payee: DAN GRUBB TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1013 38.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000/345.830 38.00 Total: $38.00 53 03/31 Till TOTAL. 789.55 ti)) rtnc: Renaint -OA Printed. 03- 31 -2nnR 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3640 Project: Type of Inspection: Address: 1(,L125 S kke APL, Date Called: Special Instructions: / Date Wanted: io -2O -ems m Requester: Phone No: -305 -es-le, Approved per applicable codes. El Corrections required prior to approval. COMMENTS: e U Inspe tor: Date: r ri $60.00 REINSPECTION FEE REQ IRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., S ite 100. Call to schedule reinspection. Receipt No.: !Date: I_.INSPECTION RECORD n�oz n�� ((Retain a copy with permit J/ INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION Y- 6300•Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 ?0 Project: �, ... .` Type Inspec ion: _ Address: I 6445 S( P4' Date Called:l A- (otJ,.n ,,-) do Special Instructions: Date Wanted: • 1 • v� (a.m. p.m. Requester: `l/CJc--- 7 Phone Phone - I Q ' Y3S Approved per applicable codes. Corrections required prior to approval. COMMENTS: 60 pJ-,) ?-07)0 ,_)A„ 1? / ,y f i_i_L__ 4 -44__. ' Alp/ :i (Pe-.S. d 1 T r `l/CJc--- 7 r S- , 71 p J t A Inspect': Dater r? C El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: • Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit PGo.s 1 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36(7 Pro'e.t: .Tr � Type of Inspection: / `` Address: 14 ZS� c- , P Date Called: _.- Special Instructions: Date Wanted: Fa m' X'- 2 I- v r p.m. Requester: Phone No: _ 305 '?1( -'r ?3I - Approved per applicable codes. Correc • • equ r o‘Woval. COMMENTS: r/% J or/fit I Ca" /- f I:13 nsr-Q 4 6 IAAJ A.9 r rv‘ie.t)' IJ` liNe__AO >1-, , iL p o 4,-- .Q ,G- 1-; ( F ` `' , G Jri Inspect kak Date: 0 $60.00 REINSPECTION FEE EdUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: oP ERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG08 -092 DATE: 04 -01 -08 PROJECT NAME: AT &T MOBILITY SITE ADDRESS: 16425 SOUTHCENTER PY X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS. ,4- :U1 A in• Division P.Dblip Works �f � 0 Fire Prevention n Planning Division Structural n Permit Coordinator 1_i DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 04 -03 -08 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Notation: DUE DATE: 05-01 -08 Approved with Conditions Not Approved (attach comments) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Look Up a Contractor, Electri n or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. License Information License CBBOVI *006D8 Licensee Name C B BOVENKAMP MC Licensee Type CONSTRUCTION CONTRACTOR UBI 601998279 Ind. Ins. Account Id #2 Business Type CORPORATION Address 1 9002 SW 152ND ST Address 2 City MIAMI County OUT OF STATE State FL Zip 33157 Phone 3052334438 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 3/28/2000 Expiration Date 8/30/2009 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date BOVENKAMP, ESTHER Cancel Date 01/01/1980 Bond Amount BOVENKAMP, GERALD #2 01/01/1980 08473969 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #2 FIDELITY & DEPOSIT CO OF MD 08473969 08/30/2001 Until Cancelled $12,000.00 08/30/2001 Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= CBBOVI *006D8 05/13/2008 HVAC SYMBOLS DUCTWORK z 12 "o ( ROUND DUCTWORK. DIAMETER INDICATED IN INCHES 20X12 x MIX MP% MIR MEW lir LAI e BDD i UP i DN RE: I 2/M0.01 i LINEAR SLOT (ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS) SUPPLY DIFFUSER, 4 -WAY SUPPLY DIFFUSER, 2 -WAY RETURN GRILLE EXHAUST GRILLE SUPPLY WALL REGISTER RETURN /EXHAUST WALL REGISTER RECTANGULAR DUCTWORK. SIZE INDICATED IN INCHES FIRST NUMBER IS SIDE SHOWN RECTANGULAR DUCTWORK. SIZE INDICATED IN INCHES FIRST NUMBER IS SIDE SHOWN. DASHED LINES INDICATE ACOUSTICAL LINER. DIMENSIONS INDICATES CLEAR INSIDE DIMENSIONS SUPPLY OR OUTSIDE AIR DUCT RETURN AIR DUCT RELIEF OR EXHAUST AIR DUCT SUPPLY OR OUTSIDE AIR DUCT UP SUPPLY OR OUTSIDE AIR DUCT DOWN RETURN AIR DUCT UP RETURN AIR DUCT DOWN RELIEF OR EXHAUST AIR DUCT UP RELIEF OR EXHAUST AIR DUCT DOWN IN -LINE 90 DEGREE DROP (RISE) IN DUCT INCLINED RISE IN DUCT INCLINED DROP IN DUCT ELBOW WITH VANES FLEXIBLE DUCT FIRE DAMPER MOTORIZED DAMPER BACKDRAFT DAMPER POINT OF DISCONNECT POINT OF CONNECTION - NEW TO EXISTING TERMINAL AIR UNIT HHW (AS APPLICABLE) DEMOLITION TEMPERATURE SENSOR THERMOSTAT DUCT MOUNTED SMOKE DETECTOR DRAWING /DETAIL REFERENCE KEY REFER TO DRAWING /DETAIL NUMBER 2 M0.01 SHEET NUMBER OF DRAWING /DETAIL PLAN NOTE REFERENCE FURNISHED & INSTALLED BY MECHANICAL FURNISHED BY MECHANICAL INSTALLED BY ELECTRICAL FURNISHED BY ELECTRICAL INSTALLED BY MECHANICAL FURNISHED & INSTALLED BY ELECTRICAL c 12 "0 ) c .) 20X12 20X12 C �C P C DN HVAC ABBREVIATIONS (ALL ABBREVIATIONS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS) A ABV AC ACCU ADJ AD AFF AH AL AMPS AP APD APPROX ARCH AS ASHRAE AUX AV B B BDD BD BEL BFF BFV BFW BHP BKR BLDG BOD BOP BOS BTU BV C CA CAP CAV CC CD CFH CFM CH CHWR CHWS CHWP CI CIRC CLG CMU CO COL COP COND CP CPVC CR CT CU CW CWS CWR CWP 'C D D DB dB DDC DESIG DEG DIA DIM DISC DISCH DN DP DPS DS DWG(S) DX E (E) EER EA EAT ECC EDB EF EFF EG EL ELEC ENCL EQUIP ESP ET EV EWB EWR EWT EXH EXT EXP. JOINT ABOVE AIR CONDITIONING AIR COOLED CONDENSING UNIT ADJUSTABLE ACCESS DOOR ABOVE FINISHED FLOOR AIR HANDLING ALUMINUM AMPERES ACCESS PANEL AIR PRESSURE DROP APPROXIMATE ARCHITECT, ARCHITECTURAL AIR SEPARATOR AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR CONDITIONING ENGINEERS AUXILIARY AIR VENT BOILER BACKDRAFT DAMPER BLOW -DOWN BELOW BELOW FINISHED FLOOR BUTTERFLY VALVE BOILER FEED WATER BRAKE HORSEPOWER BREAKER BUILDING BOTTOM OF DUCT BOTTOM OF PIPE BOTTOM OF STEEL BRITISH THERMAL UNIT BALL VALVE COMPRESSED AIR CAPACITY CONSTANT AIR VOLUME COOLING COIL CEILING DIFFUSER CUBIC FEET PER HOUR CUBIC FEET PER MINUTE CHILLER CHILLED WATER RETURN CHILLED WATER SUPPLY CHILLED WATER PUMP CAST IRON CIRCULATING CENTERLINE CEILING CONCRETE MASONRY UNIT CLEANOUT COLUMN COEFFICIENT OF PERFORMANCE CONDENSATE CONDENSATE PUMP CHLORINATED POLYVINYL CHLORIDE CONDENSATE RECEIVER COOLING TOWER CONDENSING UNIT COLD WATER CONDENSER WATER SUPPLY CONDENSER WATER RETURN CONDENSER WATER PUMP DEGREES CELSIUS DEPTH DRY BULB DECIBEL DIRECT DIGITAL CONTROL DESIGNATION DEGREE DIAMETER DIMENSION DISCONNECT DISCHARGE DOWN DIFFERENTIAL PRESSURE DIFFERENTIAL PRESSURE SWITCH DOWNSPOUT DRAWING(S) DIRECT EXPANSION EXISTING TO REMAIN ENERGY EFFICIENCY RATIO EXHAUST AIR, EACH ENTERING AIR TEMPERATURE ECCENTRIC ENTERING DRY BULB EXHAUST FAN EFFICIENCY EXHAUST GRILLE ELEVATION ELECTRICAL ENCLOSURE EQUIPMENT EXTERNAL STATIC PRESSURE EXPANSION TANK EXHAUST VALVE ENTERING WET BULB EXHAUST WALL REGISTER ENTERING WATER TEMPERATURE EXHAUST EXTERNAL EXPANSION JOINT FA FACP FC FCO FD FLA FLR FPI FPM FS FSD FT F FV FW G G GA GAL GALV GC GPH GPM GV H H HB HC HD HHWR HHWS HHWP HOA HORIZ HP HS HSTAT HSTM HTG HTR HVAC HW HYD HX HZ ID IE IN IN WG IN WC J J -BOX K KW KWH L LAT LB(S),# LDB LF LP LRA LSTM LTG LWB LWT M MAX MBH MCA MCC MD MECH MFR MG MH MIN MTD MU MUA MZ N N/A NC NEMA NIC NO NO. NOM NTS 0 OBD OC OD OF OH OPNG OPER OSA OSHA FIRE ALARM FIRE ALARM CONTROL PANEL FAN COIL FLOOR CLEANOUT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FLOOR FINS PER INCH FEET PER MINUTE FLOW SWITCH, FLOOR SINK FIRE -SMOKE DAMPER FOOT, FEET DEGREE FAHRENHEIT FACE VELOCITY FEED WATER (NATURAL) GAS GAUGE GALLON GALVANIZED GENERAL CONTRACTOR GALLONS PER HOUR GALLONS PER MINUTE GRAVITY VENTILATOR HEIGHT, HUMIDISTAT HOSE BIBB HEATING COIL HEAD, HUB DRAIN HEATING HOT WATER RETURN HEATING HOT WATER SUPPLY HEATING HOT WATER PUMP HAND -OFF- AUTOMATIC HORIZONTAL HORSEPOWER, HEAT PUMP HUMIDITY SENSOR HUMIDISTAT HIGH PRESSURE STEAM HEATING HEATER HEATING, VENTILATING AND AIR CONDITIONING HOT WATER HYDRANT HEAT EXCHANGER HERTZ INSIDE DIAMETER INVERT ELEVATION INCH INCHES WATER GAUGE INCHES OF WATER COLUMN JUNCTION BOX KILOWATT KILOWATT -HOUR LENGTH LEAVING AIR TEMPERATURE POUND(S) LEAVING DRY BULB LINEAR FEET LOW PRESSURE LOCKED ROTOR AMPS LOW PRESSURE STEAM (15 PSIG) LIGHTING LEAVING WET BULB LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPACITY MOTOR CONTROL CENTER MOTORIZED DAMPER MECHANICAL MANUFACTURER MOTOR GENERATOR MANHOLE, METAL HALIDE MINIMUM MOUNTED MAKE -UP MAKE -UP AIR UNIT MULTI -ZONE UNIT NOT APPLICABLE NOISE CRITERIA, NORMALLY CLOSED NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION NOT IN CONTRACT NORMALLY OPEN NUMBER NOMINAL NOT TO SCALE OPPOSED BLADE DAMPER ON CENTER OUTSIDE DIAMETER OVERFLOW OVERHEAD OPENING OPERATING OUTSIDE AIR U.S. DEPARTMENT OF LABOR OCCUPATIONAL SAFETY AND HEALTH ORGANIZATION P P PC PD PH PIV PLBG PNL POC POD PRESS PRS PRV PS PSF PSI PSIA PSIG PSV PV PVC Q QTY R RAD RA RCP RD RE: RECIRC REFRIG REINF REQD REV RG RH RHG RL RLA RM RPM RS RTU RWR S SA SAN SD SECT SEER SF SQFT SHT SIM SHT MTL SMACNA SOV SP SPEC SO SS ST STM STD STL STRUC SURF SUSP SV SWR SYM T TAU TEMP TDH THRU TP TS TSP TYP U U/C U/F U/G U/S UTR UL UON UPS V V VAC VAV VD VEF VEL VERT VFD VTR W W/ W/0 WB WC WPD WP WR WSHP WT PUMP PUMPED CONDENSATE PRESSURE DROP PHASE POST INDICATOR VALVE PLUMBING PANEL POINT OF CONNECTION POINT OF DISCONNECT PRESSURE PRESSURE REDUCING STATION PRESSURE REDUCING VALVE PRESSURE SWITCH POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH ABSOLUTE POUNDS PER SQUARE INCH GAUGE PRESSURE SAFETY VALVE PLUG VALVE POLYVINYL CHLORIDE QUANTITY RADIANT RETURN AIR REFLECTED CEILING PLAN, REINFORCED CONCRETE PIPE ROOF DRAIN REFERENCE, REFER RECIRCULATE REFRIGERANT REINFORCING REQUIRED REVISION, REVISE RETURN GRILLE RELATIVE HUMIDITY REFRIGERANT HOT GAS REFRIGERANT LIQUID RUNNING LOAD AMPS ROOM REVOLUTIONS PER MINUTE REFRIGERANT SUCTION ROOF TOP UNIT RETURN WALL REGISTER SUPPLY AIR SANITARY SEWER SMOKE DAMPER, STORM DRAIN SECTION SEASONAL ENERGY EFFICIENCY RATIO SUPPLY FAN SQUARE FEET SHEET SIMILAR SHEET METAL SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION SHUT OFF VALVE STATIC PRESSURE SPECIFICATION SQUARE STAINLESS STEEL, SERVICE SINK SOUND TRAP, STEAM TRAP STEAM STANDARD STEEL STRUCTURAL SURFACE SUSPEND SUPPLY VALVE SUPPLY WALL REGISTER SYMBOL THERMAL AIR UNIT TEMPERATURE TOTAL DYNAMIC HEAD THROUGH TOTAL PRESSURE TEMPERATURE SENSOR TOTAL STATIC PRESSURE THERMOSTAT TYPICAL UNDER CUT UNDERFLOOR UNDERGROUND UNDERSLAB UP THROUGH ROOF UNDERWRITERS LABORATORIES, INC. UNLESS OTHERWISE NOTED UNINTERRUPTIBLE POWER SUPPLY VOLT, VENT VACUUM VARIABLE AIR VOLUME VOLUME DAMPER VEHICLE EXHAUST FAN VELOCITY VERTICAL VARIABLE FREQUENCY DRIVE VENT THROUGH ROOF WATT, WIDTH WITH WITHOUT WET BULB WATER COLUMN WATER PRESSURE DROP WEATHER PROOF WATER RISER WATER SOURCE HEAT PUMP WATERTIGHT, WEIGHT PLUvBING GENERAL NOTES: 1. THESE DOCUMENTS WERE PREPARED PER AVAILABLE AS -BUILT DOCUMENTS. CONTRACTOR SHALL VISIT SITE TO BECOME FULLY FAMILIAR WITH THE SCOPE OF WORK AND REVIEW EXISTING CONDITIONS PRIOR TO BID. 2. EXACT LOCATION OF PLUMBING FIXTURES SHALL BE DETERMINED FROM ARCHITECTURAL DRAWINGS. 3. CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING CONDITIONS (SIZE, LOCATION, ETC.) PRIOR TO THE START OF CONSTRUCTION. CONTRACTOR SHALL BE RESPONSIBLE TO NOTIFY THE ARCHITECT /ENGINEER OF ANY DISCREPANCIES BETWEEN CONTRACT DOCUMENTS AND EXISTING CONDITIONS. 4. CONTRACTOR SHALL VERIFY IN FIELD, EXACT SEWER WASTE AND COLD WATER PIPE LOCATIONS. 5. CONTRACTOR SHALL VERIFY INVERT ELEVATIONS OF SEWER POINTS OF CONNECTION PRIOR TO THE INSTALLATION OF NEW WASTE SYSTEM. 6. CONTRACTOR SHALL VERIFY AND COORDINATE LOCATION OF ALL PLUMBING LINES WITH DUCT WORK AND ELECTRICAL SERVICES. 7. THE INSTALLATION OF ALL VALVES, UNIONS, THERMOMETERS, GAUGE, OR OTHER INDICATING OR RECORDING EQUIPMENT, OR SPECIALTIES REQUIRING FREQUENT READING, REPAIRS, ADJUSTMENT, INSPECTION, REMOVAL OR REPLACEMENT SHALL BE CONVENIENTLY AND ACCESSIBLY LOCATED WITH REFERENCE TO THE FINISHED BUILDING. 8. ALL VENTS THROUGH ROOF SHALL BE 1O' -0" FROM ALL A/C UNITS OR AIR INTAKES, ETC. 9. CONTRACTOR SHALL NOT CUT, NOTCH AND /OR BORE EXISTING JOIST, BEAMS AND /OR JOIST WITHOUT FIRST SECURING WRITTEN APPROVAL FROM ARCHITECT. 10. CONTRACTOR SHALL INSTALL DIELECTRIC UNIONS AT ALL CONNECTIONS WITH DISSIMILAR METALS. 11. CONTRACTOR SHALL ROUGH -IN ALL WASTES AND SUPPLIES TO SPECIAL EQUIPMENT ACCORDING TO MANUFACTURER'S SHOP DRAWINGS AND MAKE FINAL CONNECTIONS. ALL SUPPLIES SHALL BE VALVED. 12. SEISMIC RESTRAINTS SHALL BE REQUIRED ON SEVERAL PIECES OF EQUIPMENT WITHIN THIS PLUMBING FLOOR PLAN AND ALL REQUIREMENTS SHALL BE OBTAINED FROM THE AUTHORITY HAVING JURISDICTION. 13. INSULATE ALL EXPOSED SUPPLY AND WASTE PIPING AT HANDICAPPED ACCESSIBLE SINKS. 14. REFER TO SHEET M -003 AND M -004 FOR ALL PLUMBING SPECIFICATIONS AND WORK REQUIREMENTS. 15. CONTRACTOR SHALL PERFORM ALL WORK IN A COMPLETE AND WORKMANLIKE WAY IN COMFOMANCE WITH ALL CODES, AND MANUFACTURER'S RECOMMENDATIONS. CONTRACTOR SHALL COORDINATE WITH ARCHITECTS, ELECTRICAL AND STRUCTURAL. ALL WORK TO BE PERFORMED TO PROVIDE A COMPLETE AND WORKING SYSTEM. 16. CONTRACTOR IS RESPONSIBLE FOR ALL PERMITS, FEES, TESTING, ETC. CONTRACTOR SHALL PROVIDE A ONE YEAR WARRANTY /GURANTEE FOR ALL WORK PERFORMED UNDER THIS CONTRACT. HVAC GENERAL NOTES: REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal nd may include additional plan review fees 1. PRIOR TO STARTING THE WORK, CONTRACTOR SHALL VERIFY THAT EXISTING AIR CONDITIONING UNITS WORK PROPERLY AND CAN DELIVER THE CFM SPECIFIED. SUBMIT TO ENGINEER FOR REVIEW. 2. COORDINATE LOCATIONS OF DIFFUSERS AND GRILLES WITH SUSPENDED CEILING AND LIGHT FIXTURES. 3. WHERE DUCTS ARE USED FOR BOTH HEATING AND COOLING, THE MINIMUM INSULATION SHALL BE PER SECTION 15250 OF THE SPECIFICATION ON M -003. 4. TRANSVERSE JOINTS FOR ALL AIR SUPPLY DUCTS INSTALLED SHALL BE SEALED WITH APPROVED MASTIC. 5. VERIFY LOCATIONS AND SIZES OF EXISTING EQUIPMENT PRIOR TO COMMENCEMENT OF THE WORK. INFORM THE ENGINEER OF DISCREPANCIES. 6. COORDINATE THE LOCATION AND ELEVATION OF EQUIPMENT, DUCTWORK AND PIPING WITH OTHER TRADES, TO AVOID INTERFERENCES. 7. CONNECTION, DEMOLITION OR INTERRUPTION TO EXISTING SERVICES SHALL BE MINIMIZED AND COORDINATED WITH THE OWNER'S REPRESENTATIVE. 8. EQUIPMENT SHALL BE INSTALLED, DUCTED AND /OR PIPED IN ACCORDANCE WITH APPLICABLE CODES AN MANUFACTURERS RECOMMENDATIONS. 9. EQUIPMENT DESIGNED TO BE FIXED IN POSITION SHALL BE SECURELY FASTENED IN PLACE. 10. ALL SHEET METAL DUCTWORK SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH SMACNA DESIGN AND CONSTRUCTION STANDARDS. 11. AT COMPLETION OF INSTALLATION, BALANCE MECHANICAL UNITS AND DIFFUSERS /REGISTERS TO PROVIDE SUPPLY AIR CFM INDICATED ON PLANS. BALANCE UNIT TO PROVIDE OUTSIDE AIR AS STATED. SUBMIT 4 COPIES OF AIR BALANCE REPORT FOR APPROVAL. 12. THE LOCATION OF ACCESS PANELS FOR CONCEALED VALVES, FUSIBLE LINKS, DAMPER OPERATORS AND EQUIPMENT SHALL BE COORDINATED WITH THE ARCHITECTURAL TRADES. 13. THE MECHANICAL CONTRACTOR IS RESPONSIBLE FOR PATCHING AND REPAIRING WORK AREAS, AS A RESULT OF THEIR WORK. REPAIR TO MATCH EXISTING FINISHES. 14. ACCURATE "AS- BUILT" DRAWINGS SHALL BE MAINTAINED DURING CONSTRUCTION AND SUBMITTED FOR APPROVAL UPON COMPLETION OF INSTALLATION. INDICATE DUCT AND EQUIPMENT SIZES AND LOCATIONS. 15. CONTRACTOR SHALL PERFORM ALL WORK IN A COMPLETE AND WORKMANLIKE WAY IN CONFORMANCE WITH ALL CODES, AND MANUFACTURER'S RECOMMENDATIONS. CONTRACTOR SHALL COORDINATE WITH ARCHITECTS, ELECTRICAL AND STRUCTURAL. ALL WORK TO EE PERFORMED TO PROVIDE A COMPLETE AND WORKING SYSTEM. 16. CONTRACTOR IS RESPONSIBLE FOR ALL PERMITS, FEES, TESTING, ETC. CONTRACTOR SHALL PROVIDE A ONE YEAR WARRANTY /GUARANTEE FOR ALL WORK PERFORMED UNDER THIS CONTRACT. 17. THIS TENANT IMPROVEMENT PROJECT HAS NOT MODIFIED THE THERMAL CHARACTERISTICS OF THE ENVELOPE. 18. CONTRACTOR SHALL VERIFY THE EXISTING BUILDING'S OUTSIDE AIR SHAFT INTO THE BUILDING. ADJUST DAMPERS TO MATCH THE MECHANICAL VENTILATION REQUIREMENTS IN THESE DRAWINGS. 19. THESE DOCUMENTS WERE PREPARED PER AVAILABLE AS -BUILT DOCUMENTS. CONTRACTOR SHALL VISIT SITE TO BECOME FULLY FAMILIAR WITH THE SCOPE OF WORK AND REVIEW EXISTING CONDITIONS PRIOR TO BID. 20. CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING CONDITIONS (SIZE, LOCATION, ETC) PRIOR TO THE START OF CONSTRUCTION. CONTRACTOR SHALL BE RESPONSIBLE TO NOTIFY THE ARCHITECT /ENGINEER OF ANY DISCREPANCIES BETWEEN CONTRACT DOCUMENTS AND EXISTING CONDITIONS. 21. CONTRACTOR SHALL NOT CUT, NOTCH AND /OR BORE EXISTING JOIST, BEAMS AND /OR JOIST WITHOUT FIRST SECURING WRITTEN APPROVAL FROM ARCHITECT. FILE C i PY Permit 1 1v. Plar review apprc val is subject to errors and omissions. Approval of consl ruction documents does not authorize the violation of ar y adopted code or ordinance. Receipt of approved Field C y and cone 17 acknowledged: By .� r Dater City of Tukwila BUILDING DIVISION SEPARATE PERMIT REQUIRED FOR: J Mechanical IL Electrical 0 Plumbing 0 Gas Piping City of Tukwila ` iG DIVISION >t_6l `DI RECEIVED APR 01 2008 PERMIT CENTER ?GO3 072 Arc \S I onia icI0t coPyRIG rr 0 200e CARTER & BURGESS, INC. 1 03 -29 -08 TENANT CHANGES at &t Carteriturgess Carter & Burgess, Inc. 4 Hutton Centre Drive, Suite 800 Santa Ana, California 92707 TEL: (714) 327 -1600 FAX: (714) 327 -1601 EXPIRES 03/15/10 ISSUES /REVISIONS 03 -19 -08 ISSUE FOR PERMIT NO. DATE DESCRIPTION 16425 Southcenter Parkway TU KW I LA, WA DESIGNED BY: KL CHECKED BY: MV DRAWN BY: KL PROJECT NUMBER: SCALE: APPROVED BY: MV 441805.011.039.0001 NONE MECHANICAL AND PLUMBING LEGEND, SYMBOLS AND ABBREVIATIONS M -0 2006 IECC Report Date: 03/14/08 Data filename: R :WOB1Cingular\Washington State116425 Southcenter, WAlcalcslmech.cck Section 1: Project Information Project Title: at &t Construction Site: Owner /Agent: 16425 Southcenter Parkway at &t Mobility, L.L.C. Tukwila, WA 1920 Customer Care Way Atwater, CA 95301 Section 2: General Information Building Location (for weather data): Climate Zone: Heating Degree Days (base 65 degrees F): Cooling Degree Days (base 50 degrees F): Project Type: Section 3: Mechanical Systems List Quantity System Type & Des pt_.iQn 1 HVAC System 1: Heating: Central Furnace, Gas / Cooling: Rooftop Package Unit, Capacity > =90 - <135 kBtu /h, Air - Cooled Condenser / Single Zone 1 HVAC System 2: Split System Heat Pump, Cooling Capacity <54 kBtu /h, Air- Cooled Condenser 1 Single Zone Section 4: Requirements Checklist Requirements Specific To: HVAC System 1 1. Newly purchased heating equipment meets the heating efficiency requirements . Z 2. Equipment minimum efficiency: Rooftop Package Unit: 10.1 EER A 3. Cooling system provides a means to relieve excess outdoor air during economizer operation. O 4. Integrated air economizer required Requirements Specific To: HVAC System 2 : ZxS 1. Equipment minimum efficiency: Heat Pump: 6.8 HSPF, 10,0 SEER A 2. Heat pump thermostat required when supplemental electric resistance heat is installed Generic Requirements: Must be met by all systems to which the requirement is applicable: 1. Load calculations per 2001 ASHRAE Fundamentals 1 2. Plant equipment and system capacity no greater than needed to meet loads - Exception: Standby equipment automatically off when primary system is operating - Exception: Multiple units controlled to sequence operation as a function of load t 3. Minimum one temperature control device per system O 4. Minimum one humidity control device per installed humidification/dehumidification system O 5. Thermostatic controls has 5 degrees F deadband Exception: Thermostats requiring manual changeover between heating and cooling 6. Automatic Controls: Setback to 55 degrees F (heat) and 85 degrees F (cool); 7-day clock, 2 -hour occupant override, 10 -hour backup COMcheck Software Version 3.4.1 Mechanical Compliance Certificate Tukwila, Washington 40 5524 1686 Addition Designer /Contractor: Jacobs Cater Burgess 4 Hutton Centre Drive, Suite 800 Santa Ana, OA 92707 Page 1 of 2 - Exception: Continuously operating zones Exception: 2 kW demand or Tess, submit calculations /. Outside -air source for ventilation; system capable of reducing OSA to required minimum 8. R -5 supply and return air duct insulation in unconditioned spaces R -8 supply and retum air duct insulation outside the building R -8 insulation between ducts and the building exterior when ducts are part of a building assembly Exception: Ducts located within equipment Exception: Ducts with interior and exterior temperature difference not exceeding 15 degrees F. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at static pressures less than 2 inches w.g. pressure classification "K9. Mechanical fasteners and sealants used to connect ducts and air distribution equipment r10.Ducts sealed - longitudinal seams on rigid ducts; transverse seams on all ducts; UL 181Aor 181B tapes and mastics 0 11. Hot water pipe insulation: 1 in. for pipes < =1.5 in. and 2 in. for pipes >1.5 in. Chilled water /refrigerant/brine pipe insulation: 1 in. for pipes < =1.5 in. and 1.5 in. for pipes >1.5 in. Steam pipe insulation: 1.5 in. for pipes < -1.5 in. and 3 in. for pipes >1.5 in. Exception: Piping within HVAC equipment Exception: Fluid temperatures between 55 and 105 degrees F Exception: Fluid not heated or cooled Exception: Runouts <4 ft in length 12.Operation and maintenance manual provided to building owner 13.Balancing devices provided in accordance with IMC 603.15 !`14.Motorized, automatic shutoff dampers required on exhaust and outdoor air supply openings ( - Exception: Gravity dampers acceptable in buildings <3 stories - Exception: Gravity dampers acceptable in systems with outside or exhaust air flow rates less than 300 cfm where dampers are interlocked with fan 0 15.Stair and elevator shaft vents are equipped with motorized dampers Section 5: Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 2006 IECC requirements in COMcheck Version 3.4.1 and to comply with the mandatory requirements In the Requirements Checklist. Name - Title" Signature s -( 0-0 )( 7 7- i Y -o1 Date Page 2 of 2 RECEIVED APR '01 2008 PERMIT CENTER COPYRIGHT 0 2008 CARTER & BURGESS, INC, at &t Carter::Burgess Carter & Burgess, Inc. 4 Hutton Centre Drive, Suite 800 Santa Ana, California 92707 TEL: (714) 327-1600 FAX: (714) 327 -1601 1 EXPIRES 03/15/10 ISSUES /REVISIONS 1 03- 29-08 TENANT CHANGES 03 -19 -08 ISSUE FOR PERMIT NO. DATE DESCRIPTION DRAWN BY: KL PROJECT NUMBER: SCALE: MECHANICAL COMPLIANCE FORMS 16425 Southcenter Parkway TU KW I LA, WA DESIGNED BY: KL CHECKED BY: MV APPROVED BY: MV 441805.011.039.0001 NONE M -002 SECTION 15010 GENERAL PROVISIONS PART 1.00 - GENERAL 1.01 GENERAL REQUIREMENTS A. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND OTHER CONDITIONS AND DIVISION 1 - GENERAL REQUIREMENTS SECTIONS, APPLY TO THE WORK SPECIFIED IN THIS SECTION. B. INCLUDE ALL LABOR, MATERIAL EQUIPMENT, TRANSPORTATION AND SERVICES TO FURNISH AND INSTALL COMPLETE MECHANICAL SYSTEMS AND ALTERATIONS AS SHOWN ON THE DRAWINGS AND HEREIN SPECIFIED. THE WORK INCLUDES, BUT IS NOT LIMITED TO: 1. ALL PLUMBING WORK. 2. CONNECTION TO ALL UTILITIES. 3. HEATING AND AIR CONDITIONING. 4. INSULATION. 5. TEMPERATURE CONTROLS. 1.02 DESCRIPTION OF WORK A. EXTENT OF MECHANICAL WORK IS INDICATED ON DRAWINGS OR SPECIFIED IN DIVISION 15 SECTIONS OF THE SPECIFICATION. PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, SUPERVISION AND SERVICE NECESSARY FOR A COMPLETE MECHANICAL SYSTEM. 1.03 QUALITY ASSURANCE A. ALL WORK ACCOMPLISHED UNDER THESE SPECIFICATIONS SHALL BE IN ACCORDANCE WITH REQUIREMENTS AND RECOMMENDATIONS OF THE LOCAL COUNTY, STATE, ACCEPTED MECHANICAL CODE, PLUMBING CODE, BUILDING CODE, ETC. UNDER THIS JURISDICTION B. IN ADDITION, FOLLOW ALL REQUIREMENTS PERTAINING TO THE MALL TENANT DESIGN MANUAL. 1.04 SUBMITTALS A. CONTRACTOR SHALL SUBMIT FOR REVIEW, SIX COPIES OF SHOP DRAWINGS, LITERATURE, AND EQUIPMENT LIST WITHIN 30 DAYS AFTER CONTRACT IS LET. FIRE PROTECTION DRAWINGS SHALL BE SUBMITTED PER DIVISION 1. B. SUBMIT PRIOR TO FABRICATION OR DELIVERY. C. SUBMIT COMPLETE, AT ONE TIME. PARTIAL SUBMITTALS WILL NOT BE CONSIDERED (EXCEPT AS NOTED ABOVE FOR CONTROLS AND DUCTWORK). D. CATALOG SHEETS SHALL BE COMPLETE AND THE ITEM OR MODEL TO BE USED SHALL BE CLEARLY MARKED. E. LIST SUBSTITUTE ITEMS SEPARATELY AND SO IDENTIFIED. PART 2.00 - PRODUCTS 2.01 MATERIALS A. ALL MATERIALS SHALL BE NEW AND OF MANUFACTURERS SPECIFIED HEREIN. THEY SHALL BE U.S. MADE (EXCEPT CANADIAN COPPER PIPE IS ACCEPTABLE) AND BEAR THE U.L., ETL OR CSA LABEL WHERE POSSIBLE. B. ALL EQUIPMENT SHALL BE REGULARLY CATALOGUED ITEMS OF THE MANUFACTURER AND IN USE FOR AT LEAST TWO YEARS AND SHALL BE SUPPLIED AS A COMPLETE UNIT IN ACCORDANCE WITH THE MANUFACTURER'S STANDARD SPECIFICATIONS AND ANY OPTIONAL ITEMS REQUIRED FOR PROPER INSTALLATION FOR THE EQUIPMENT UNLESS OTHERWISE NOTED. ALL EQUIPMENT AND MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND BEST TRADE PRACTICES. 2.02 SUBSTITUTIONS A. IN ALL CASES IN THIS SPECIFICATION WHERE AN ARTICLE IS FOLLOWED BY THE WORDS 'OR APPROVED EQUAL ", THE ARCHITECT IS THE SOLE JUDGE OF THE QUALITY OF THE PROPOSED SUBSTITUTION. B. WHEN THE ARCHITECT /OWNER APPROVES A SUBSTITUTION, THE APPROVAL IS GIVEN WITH THE UNDERSTANDING THAT THE CONTRACTOR GUARANTEES THE ARTICLE OR MATERIAL SUBSTITUTED TO BE EQUAL TO OR BETTER IN EVERY RESPECT THAN THE ARTICLE OR MATERIAL SPECIFIED. THE CONTRACTOR SHALL ALSO ASSUME COMPLETE RESPONSIBILITY THAT THE ARTICLE OR MATERIAL WILL FIT THE JOB AS FAR AS SPACE, ACCESS AND SERVICING REQUIREMENTS. C. WHERE SEVERAL MATERIALS ARE SPECIFIED BY NAME FOR ONE USE, SELECT FOR USE ANY OF THOSE SO SPECIFIED. NOTE THAT EQUIPMENT LAYOUT IS BASED ON EQUIPMENT LISTED IN EQUIPMENT SCHEDULES. ANY OTHER EQUIPMENT USED MUST FIT IN AVAILABLE SPACE WITH ALL ACCESS AND SERVICING REQUIREMENTS MAINTAINED. IT IS THE CONTRACTOR'S RESPONSIBILITY TO CHECK THAT THIS EQUIPMENT WILL MEET THESE REQUIREMENTS. D. WHENEVER ITEM OR CLASS OF MATERIAL IS SPECIFIED EXCLUSIVELY BY DETAIL SPECIFICATION, TRADE NAME, MANUFACTURER'S NAME OR BY CATALOG REFERENCE, USE ONLY SUCH ITEM, UNLESS WRITTEN APPROVAL IS GIVEN FOR SUBSTITUTION PRIOR TO BID. PART 3.00 - EXECUTION 3.01 DRAWINGS A. THE MECHANICAL DRAWINGS ARE GENERALLY DIAGRAMMATIC. COMPLETE DETAILS OF THE BUILDING WHICH AFFECT THE MECHANICAL INSTALLATION MAY NOT BE SHOWN. FOR ADDITIONAL DETAILS, THE CONTRACTOR IS REFERRED TO THE ARCHITECTURAL, STRUCTURAL, & ELECTRICAL DRAWINGS. 3.02 CODES, ORDINANCES AND PERMITS A. ALL WORK SHALL COMPLY WITH ALL APPLICABLE CODES AND ORDINANCES. TAKE OUT AND PAY FOR ALL INSPECTION FEES AND PERMITS. COMPLIANCE WITH CODES AND ORDINANCES SHALL BE AT THE CONTRACTOR'S EXPENSE. INCLUDE ALL CONNECTION AND PERMIT FEES IN BID. CONTRACTOR SHALL CONTACT L &I FOR INSPECTION OF ALL PRESSURE VESSELS IN A TIMELY MANNER BEFORE OCCUPANCY OF THE BUILDING. 3.04 TESTING A. WATER PIPING TEST ALL WATER PIPING SYSTEMS AT 125 PSI WATER PRESSURE AND HOLD FOR FOUR (4) HOURS. TEST IN SECTIONS BEFORE COVERING. TEST ENTIRE SYSTEM WHEN COMPLETELY INSTALLED. REPAIR ANY DEFECTS SHOWN BY TEST AND RETEST UNTIL ENTIRELY TIGHT. B. WASTE AND SEWER PIPING TEST ALL WASTE, SEWER AND VENT PIPING BY FILLING WITH WATER TO ROOF. HOLD FOR FOUR HOURS. TEST IN SECTIONS AS WORK PROGRESSES. REPAIR ANY DEFECTS SHOWN BY TEST AND RETEST UNTIL ENTIRELY TIGHT. C. VALVES TEST ALL VALVE BONNETS FOR TIGHTNESS. OPERATE ALL VALVES AT LEAST ONCE FROM CLOSED -TO- OPEN -TO- CLOSED WHILE UNDER PRESSURE. 3.05 CLEAN UP AND HOUSEKEEPING A. LEAVE ALL EQUIPMENT CLEAN AND READY FOR USE. B. REMOVE ALL LABELS, PAINT, PLASTER, ETC., FROM FIXTURES, EQUIPMENT AND PIPING. 3.06 OPERATING INSTRUCTIONS AND MAINTENANCE MANUALS A. SCOPE: 1. PROVIDE COMPLETE OPERATING AND MAINTENANCE INSTRUCTIONS AND 2. PROVIDE FOUR COPIES OF EACH BOUND INTO BOOKLET FORM. 3. DELIVER BOOKLETS TO THE ARCHITECT BEFORE FINAL INSPECTION. B. CONTENTS: EACH BOOKLET SHALL CONTAIN AT LEAST, BUT NOT LIMITED TO MAINTENANCE INSTRUCTIONS AND PARTS LIST AS FOLLOWS: 1. BASIC DESCRIPTION OF ALL SYSTEMS. 2. DESCRIPTION OF ROUTINE MAINTENANCE REQUIRED FOR EACH COMPONENT, 3. SUGGESTED FREQUENCY OF MAINTENANCE. 4. PARTS LIST OF ALL EQUIPMENT. 5. OPERATING INSTRUCTIONS AND WARRANTIES ON ALL EQUIPMENT. 6. CONTROLS: AS -BUILT WIRING DIAGRAMS 7. MECHANICAL AS -BUILT DRAWINGS. 8. TROUBLE - SHOOTING LIST. 9. NAME, ADDRESS, PHONE NUMBER OF ALL CONTRACTORS AND SUPPLIERS 3.07 RECORD DRAWINGS A. PROVIDE THE ARCHITECT WITH RECORD DRAWINGS. RECORD DRAWINGS SHALL BE NEW, REPRODUCIBLE MYLARS AND SHALL SHOW THE MEASURED LOCATIONS OF ALL CONCERNED PORTIONS OF THE WORK AND SHALL SHOW ALL CHANGES THE CONTRACTOR HAS MADE. B. DRAWINGS MUST SHOW ALL ADDENDUM ITEMS, CHANGE ORDERS AND DEVIATIONS FROM THE PLANS. 3.08 INTERFERENCE A. THE MECHANICAL CONTRACTOR'S ATTENTION IS CALLED TO THE RESTRICTED SPACE FOR INSTALLATION OF MECHANICAL SYSTEMS. OFFSETS, REROUTING AND COORDINATION WILL BE REQUIRED TO FIT ALL ELEMENTS IN AVAILABLE SPACE AND THE MECHANICAL CONTRACTOR SHALL INCLUDE PROVISIONS FOR SUCH IN HIS BID. B. DUCTWORK AND PIPING SHALL BE ROUTED TO CLEAR LIGHT FIXTURES. COORDINATE ROUTING OF DUCTWORK AND PIPING WITH EACH OTHER SO GRADE OF PIPING CAN BE ACCOMPLISHED, AND TO FIT IN AVAILABLE SPACE. C. DUCTWORK SHALL BE INSTALLED AS REQUIRED TO CLEAR LIGHT FIXTURES AND TO FIT IN AVAILABLE SPACE. PROVIDE OFFSETS, V OR SLEEVES AS REQUIRED. MAINTAIN EQUIVALENT FREE AREA OF DUCTWORK. D. DUCTWORK TAKES PRECEDENCE OVER PIPING FOR AVAILABLE SPACE AND ROUTING. COORDINATE INSTALLATION BASED ON THIS PRECEDENCE. E. DUCTWORK AND /OR PIPING SHALL NOT BE RUN OVER ELECTRICAL PANELS. 3.09 WORKMANSHIP A. ALL WORK SHALL BE INSTALLED IN ACCORDANCE WITH BEST TRADE PRACTICE. ANY SUBSTANDARD WORKMANSHIP SHALL BE REMOVED AND REPLACED AT NO EXTRA COST TO THE OWNER, 3.10 SEISMIC RESTRAINTS A. PROVIDE SEISMIC RESTRAINTS ON ALL PIPING AND DUCTWORK IN ACCORDANCE WITH THE "GUIDLINES FOR SEISMIC RESTRAINTS OF MECHANICAL SYSTEMS AND PLUMBING PIPING SYSTEMS" AS PREPARED BY SMACNA AND THE PLUMBING PIPING INSTITUTE COUNCIL. B. PROVIDE SEISMIC RESTRAINTS ON ALL EQUIPMENT AND PROVIDE SLACK CABLE RESTRAINTS ON ALL SUSPENDED EQUIPMENT. COMPLETE RESTRAINT SYSTEM SHALL BE SELECTED, SHOP DRAWINGS SEALED BY AND CERTIFICATION PROVIDED BY A PROFESSIONAL STRUCTURAL ENGINEER. END OF SECTION 15010 SECTION 15030 ELECTRICAL PROVISIONS TO MECHANICAL WORK PART 1.00 - GENERAL 1.01 DESCRIPTION A. GENERAL REQUIREMENTS DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND OTHER CONDITIONS AND DIVISION 1 - GENERAL REQUIREMENTS SECTIONS, APPLY TO THE WORK SPECIFIED IN THIS SECTION. 1.02 STANDARDS A. FOR ELECTRICAL EQUIPMENT AND PRODUCTS, EMPLOY WITH APPLICABLE NEMA STANDARDS, AND REFER TO NEMA STANDARDS FOR DEFINITIONS OF TERMINOLOGY HEREIN. COMPLY WITH NATIONAL ELECTRICAL CODE (NFPA 70) FOR WORKMANSHIP AND INSTALLATION REQUIREMENTS AND TO APPLICABLE SECTIONS OF DIVISION 16 OF THE SPECIFICATIONS. PART 2.00 - PRODUCTS A. MANUFACTURER 1. EXCEPT WHERE ITEM OF MECHANICAL EQUIPMENT (WHICH OTHERWISE COMPLIES WITH REQUIREMENTS) MUST BE INTEGRALLY EQUIPPED WITH MOTOR PRODUCED BY ANOTHER MANUFACTURER, PROVIDE MOTORS FOR MECHANICAL EQUIPMENT. CHARACTERISTICS M OTOR CH 1. EXCEPT WHERE MORE STRINGENT REQUIREMENTS ARE INDICATED, AND EXCEPT WHERE REQUIRED ITEM OF MECHANICAL EQUIPMENT CANNOT BE OBTAINED WITH FULLY COMPLYING MOTOR, COMPLY WITH THE FOLLOWING REQUIREMENTS FOR MOTORS OF MECHANICAL WORK: A. TEMPERATURE RATING: RATED FOR 40 DEG. C ENVIRONMENT WITH MAXIMUM 50 DEG. C TEMPERATURE RISE FOR CONTINUOUS DUTY AT FULL LOAD (CLASS A INSULATION). B. STARTING CAPABILITY: PROVIDE EACH MOTOR CAPABLE OF MAKING STARTS AS FREQUENTLY AS INDICATED BY AUTOMATIC CONTROL SYSTEM, AND NOT LESS THAN 5 STARTS /HOUR FOR MANUALLY CONTROLLED MOTORS. C. PHASES AND CURRENT CHARACTERISTICS : PROVIDE SQUIRREL -CAGE INDUCTION POLYPHASE MOTORS FOR 1 HP AND LARGER, AND PROVIDE CAPACITOR -START SINGLE -PHASE MOTORS FOR 3/4 HP AND SMALLER, EXCEPT 1/6 HP AND SMALLER MAY, AT EQUIPMENT MANUFACTURER'S OPTION, BE SPLIT-PHASE TYPE. COORDINATE CURRENT CHARACTERISTICS WITH POWER SPECIFIED IN DIVISION -16 SECTIONS, AND WITH INDIVIDUAL EQUIPMENT REQUIREMENTS SPECIFIED IN OTHER DIVISION -15 REQUIREMENTS. FOR 2 -SPEED MOTORS PROVIDE 2 SEPARATE WINDINGS ON POLYPHASE MOTORS. DO NOT PURCHASE MOTORS UNTIL POWER CHARACTERISTICS AVAILABLE AT LOCATIONS OF MOTORS HAVE BEEN CONFIRMED, AND UNTIL ROTATION DIRECTIONS HAVE BEEN CONFIRMED. D. SERVICE FACTOR: 1.15 FOR POLYPHASE MOTORS, AND 1.35 FOR SINGLE -PHASE MOTORS. C. MOTOR CONSTRUCTION 1. PROVIDE GENERAL PURPOSE, CONTINUOUS DUTY MOTORS, DESIGN " B " , EXCEPT " C " WHERE REQUIRED FOR HIGH STARTING TORQUE. A. FRAMES: NEMA NO. 48. B. BEARINGS: BALL OR ROLLER BEARINGS WITH INNER AND OUTER SHAFT SEALS, PERMANENTLY SEALED. WHERE BELT DRIVES AND OTHER DRIVES PRODUCE LATERAL OR AXIAL THRUST IN MOTOR, PROVIDE BEARINGS DESIGNED TO RESIST THRUST LOADING. REFER TO INDIVIDUAL SECTIONS OF DIVISION -15 FOR FRACTIONAL -HP LIGHT -DUTY MOTORS WHERE SLEEVE -TYPE BEARINGS ARE PERMITTED. C. ENCLOSURE TYPE: EXCEPT AS OTHERWISE INDICATED PROVIDE OPEN DROP -PROOF MOTORS FOR INDOOR USE WHERE SATISFACTORILY HOUSED OR REMOTELY LOCATED DURING OPERATION, AND PROVIDE GUARDED DRIP PROOF MOTORS WHERE EXPOSED TO CONTACT BY EMPLOYEES OR BUILDING OCCUPANTS. PROVIDE WEATHER- PROTECTED TYPE I FOR OUTDOOR USE, TYPE II WHERE NOT HOUSED. REFER TO INDIVIDUAL SECTIONS OF DIVISION -15 FOR OTHER ENCLOSURE REQUIREMENTS. D. OVERLOAD PROTECTION: PROVIDE BUILT -IN THERMAL OVERLOAD PROTECTION FOR 120V MOTORS. E. EFFICIENCY: MOTORS ARE TO BE "ENERGY EFFICIENT" HAVING MINIMUM EFFICIENCY AS SCHEDULED IN ACCORDANCE WITH IEEE STANDARD 112, TEST METHOD B. F. PROVIDE MOTORS WITH MINIMUM 85% POWER FACTOR. WHERE LESS THAN 85 %, PROVIDE POWER FACTOR CORRECTION TO MINIMUM 90% PER ENERGY CODES. D. NAMEPLATE PROVIDE METAL NAMEPLATE ON EACH MOTOR, INDICATING FULL IDENTIFICATION OF MANUFACTURER, RATINGS, CHARACTERISTICS, CONSTRUCTION, SPECIAL FEATURES, AND SIMILAR INFORMATION. 2.02 STARTERS, ELECTRICAL DEVICES AND WIRING A. MOTOR STARTER MANUFACTURER 1. EXCEPT WHERE ITEM OF MECHANICAL EQUIPMENT MUST BE INTEGRALLY FURNISHED WITH MOTOR STARTER PRODUCED BY ANOTHER MANUFACTURER, PROVIDE MOTOR STARTERS FOR MECHANICAL EQUIPMENT MANUFACTURED BY ONE OF THE FOLLOWING: CUTLER - HAMMER, GE OR SQUARE D. B. MOTOR STARTER CHARACTERISTICS 1. COMPLY WITH NEMA STANDARDS AND NEC. PROVIDE TYPE I GENERAL PURPOSE ENCLOSURES WITH PAD LOCK EARS, AND WITH FRAMES AND SUPPORTS FOR MOUNTING ON WALL, FLOOR OR PANEL AS INDICATED. PROVIDE TYPE AND SIZE OF STARTER RECOMMENDED BY MOTOR MANUFACTURER AND EQUIPMENT MANUFACTURER FOR APPLICABLE PROTECTION AND START -UP CONDITION; REFER TO INDIVIDUAL EQUIPMENT SECTIONS FOR BASIC LOAD REQUIREMENTS. A. MANUAL SWITCHES: PROVIDE MANUAL SWITCH AND PILOT LIGHT FOR MOTORS 1/2 HP AND SMALLER, EXCEPT W HERE INTERLOCK OR AUTOMATIC OPERATION IS INDICATED. 1) OVERLOAD PROTECTION: PROVIDE MELTING ALLOY TYPE THERMAL OVERLOAD RELAYS. B. MAGNETIC STARTERS: PROVIDE MAGNETIC STARTERS FOR 3 PHASE MOTORS AND FOR SMALLER MOTORS WHERE INTERLOCK OR AUTOMATIC OPERATION IS INDICATED. INCLUDE THE FOLLOWING: 1) HAND - OFF -AUTO SWITCH AND PILOT LIGHTS, PROPERLY ARRANGED FOR SINGLE -SPEED OR MULTI -SPEED OPERATION AS INDICATED. 2) TRIP -FREE THERMAL OVERLOAD RELAYS, EACH PHASE. 3) INTERLOCKS, PNEUMATIC SWITCHES, AND SIMILAR DEVICES AS REQUIRED FOR COORDINATION WITH CONTROL REQUIREMENTS OF DIVISION -15 CONTROLS SECTIONS. 4) BUILT -IN 120 -VOLT CONTROL CIRCUIT TRANSFORMER, FUSED FROM LINE SIDE, WHERE SERVICE EXCEEDS 240 VOLTS. WHEN A TRANSFORMER ISN'T USED THE CONTROL COIL SHALL BE FUSED. 5) EXTERNALLY OPERATED MANUAL RESET. 6) UNDERVOLTAGE RELEASE OR PROTECTION FOR EACH PHASE. PART 3.00 - EXECUTION 3.01 STARTERS A. PROVIDE STARTERS AND WIRING DEVICES FOR MOTORS. INSTALLATION BY DIVISION 16000. 3.02 MOTORS A. INSTALL MOTORS ON MOTOR MOUNTING SYSTEMS IN ACCORDANCE WITH MOTOR MANUFACTURER'S INSTRUCTIONS, SECURELY ANCHORED TO RESIST TORQUE, DRIVE THRUSTS, AND OTHER EXTERNAL FORCES INHERENT IN MECHANICAL WORK. SECURE SHEAVES AND OTHER DRIVE UNITS TO MOTOR SHAFTS WITH KEYS AND ALLEN SET SCREWS, EXCEPT MOTORS OF 1/3 HP AND LESS MAY BE SECURED WITH ALLEN SCREWS ON FLAT SURFACES OF SHAFT. UNLESS OTHERWISE INDICATED, SET MOTOR SHAFTS PARALLEL WITH MACHINE SHAFTS. 3.03 EQUIPMENT FABRICATION A. FABRICATE MECHANICAL EQUIPMENT FOR SECURE MOUNTING OF MOTORS AND OTHER ELECTRICAL ITEMS INCLUDING IN WORK. PROVIDE EITHER PERMANENT ALIGNMENT OF MOTORS WITH EQUIPMENT, OR ADJUSTABLE MOUNTINGS AS APPLICABLE FOR BELT DRIVES, GEAR DRIVES, SPECIAL COUPLINGS AND SIMILAR INDIRECT COUPLING OF EQUIPMENT. PROVIDE SAFE, SECURE, DURABLE, AND REMOVABLE GUARDS FOR MOTOR DRIVES, ARRANGED FOR LUBRICATION AND SIMILAR RUNNING MAINTENANCE WITHOUT REMOVAL OF GUARDS. END OF SECTION 15030 SECTION 15050 MECHANICAL IDENTIFICATION PART 1.00 - GENERAL 1.01 GENERAL REQUIREMENTS A. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND OTHER CONDITIONS AND DIVISION 1 - GENERAL REQUIREMENTS SECTIONS, APPLY TO THE WORK SPECIFIED IN THIS SECTION. 1.02 STANDARDS A. ANSI COMPLIANCE COMPLY WITH ANSI A13.1 FOR LETTERING SIZE, COLORS, AND INSTALLED VIEWING ANGLES OF IDENTIFICATION DEVICES. PART 2.00 PRODUCTS 2.01 ENGRAVED PLASTIC - LAMINATE SIGNS A. PROVIDE ENGRAVED STOCK MELAMINE PLASTIC LAMINATE, COMPLYING WITH FS L- P -387, ENGRAVED WITH ENGRAVER'S STANDARD LETTER STYLE OF SIZES AND WORDING, BLACK WITH WHITE CORE (LETTER COLOR) EXCEPT AS OTHERWISE INDICATED, PUNCHED FOR MECHANICAL FASTENING EXCEPT WHERE ADHESIVE MOUNTING IS NECESSARY BECAUSE OF SUBSTRATE. PROVIDE 1/16" THICKNESS FOR UNITS UP TO 20 SQ. IN OR 8" LENGTH; 1/8" FOR LARGER UNITS. PROVIDE FASTENING PER SELF - TAPPING STAINLESS STEEL SCREWS, EXCEPT CONTACT -TYPE PERMANENT ADHESIVE WHERE SCREWS CANNOT OR SHOULD NOT PENETRATE SUBSTRATE. PROVIDE FOR ALL EQUIPMENT. 2.02 ELECTRICAL EQUIPMENT A. ON ALL MECHANICAL EQUIPMENT THAT HAS POWER CONNECTORS, PROVIDE WITH PERMANENT MARKER, THE ELECTRICAL PANEL AND BREAKER NUMBER. MARK ON DISCONNECT. PART 3.00 - EXECUTION 3.01 MECHANICAL EQUIPMENT IDENTIFICATION A. MECHANICAL EQUIPMENT IDENTIFICATION INSTALL ENGRAVED PLASTIC LAMINATE SIGN ON OR NEAR EACH MAJOR ITEM OF MECHANICAL EQUIPMENT AND EACH OPERATING DEVICE. PROVIDE SIGNS FOR WATER HEATERS, FANS, HVAC UNITS AND OTHER OPERATIONAL DEVICES. END OF SECTION 15050 SECTION 15060 PIPE TUBE & FITTINGS PART 1.00 - GENERAL 1.01 GENERAL REQUIREMENTS A. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND OTHER CONDITIONS AND DIVISION 1 - GENERAL REQUIREMENTS SECTIONS, APPLY TO THE WORK SPECIFIED IN THIS SECTION. 1.02 QUALITY ASSURANCE A. CERTIFY BRAZING PROCEDURES, BRAZERS, AND OPERATORS IN ACCORDANCE WITH ANSI B31.5. PART 2.00 - PRODUCTS 2.01 PIPING MATERIALS A. COPPER TUBE: ASTM B88. B. DWV COPPER TUBE: ASTM B 306. C. HUBLESS CAST -IRON SOIL PIPE: CISPI 301, WITH COUPLING ASSEMBLY, CISPI 310. D. STEEL PIPE: ASTM 106B, SCH 40, TREADED. 2.02 PIPE /TUBE FITTINGS A. CAST -IRON FLANGED FITTINGS: ANSI B16.1. B. CAST -IRON THREADED FITTINGS: ANSI B16.4. C. MALLEABLE IRON THREADED UNIONS: ANSI B16.3; GALVANIZED PIPING SYSTEMS. D. MALLEABLE IRON THREADED UNIONS: ANSI B16.39. E. DUCTILE IRON PRESSURE PIPING FITTINGS: ANSI A21.10; AWWA C110 F. THREADED PIPE PLUGS: ANSI 816.14. G. CAST -IRON THREADED DRAINAGE FITTINGS: ANSI B16.12. H. PIPE NIPPLES: SAME PIPING MATERIAL AS CONNECTING PIPING; SCHEDULE 80 FOR 1 -1/2 UNTHREADED LENGTH WITH PIPE SIZES LESS THAN 1 -1/4 "; NO CLOSE NIPPLES ALLOWED. L WROUGHT - COPPER SOLDER -JOINT FITTINGS: ANSI B16.22. J. CAST - COPPER SOLDER -JOINT DRAINAGE FITTINGS: ANSI B16.23. K. WROUGHT - COPPER SOLDER -JOINT DRAINAGE FITTINGS: ANSI 816.29. L. COPPER -TUBE UNIONS: ANSI B16.15. M. RUBBER - GASKET JOINTS: ANSI A21.11; AWWA C111. N. HUBLESS CAST -IRON SOIL PIPE FITTINGS: CISPI 301. 0. HUB -AND SPIGOT CAST -IRON PIPE FITTINGS: ASTM A74. 2.03 MISCELLANEOUS PIPING MATERIALS /PRODUCTS A. SOLDERING MATERIALS: PROVIDE ONE OF THE FOLLOWING FOR EACH SERVICE: TIN -LEAD SOLDER: ASTM B32, GRADE 50A; FOR DRAINAGE PIPING OR TIN - ANTIMONY SOLDER: ASTM 832, GRADE 95TH FOR PRESSURE PIPING. B. PIPING CONNECTORS FOR DISSIMILAR NON - PRESSURE PIPE ELASTOMERIC ANNULAR RING INSERT, OR ELASTOMERIC FLEXIBLE COUPLING SECURED AT EACH END WITH STAINLESS STEEL CLAMPS, SIZED FOR EXACT FIT TO PIPE ENDS AND SUBJECT TO APPROVAL BY PLUMBING CODE. PART 3.00 - EXECUTION 3.01 GENERAL A. INSTALL PIPE, TUBE AND FITTINGS IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES WHICH WILL ACHIEVE PERMANENTLY LEAKPROOF PIPING SYSTEMS, CAPABLE OF PERFORMING EACH INDICATED SERVICE WITHOUT PIPING FAILURE. INSTALL EACH RUN WITH MINIMUM JOINTS AND COUPLINGS, BUT WITH ADEQUATE AND ACCESSIBLE UNIONS FOR DISASSEMBLY AND MAINTENANCE REPLACEMENT OF VALVES AND EQUIPMENT. REDUCE SIZES (WHERE INDICATED) BY USE OF REDUCING FITTINGS. ALIGN PIPING ACCURATELY AT CONNECTIONS, WITH 1/16" MISALIGNMENT TOLERANCE. 3.02 THREAD PIPE A. THREAD PIPE IN ACCORDANCE WITH ANSI B2.1. APPLY PIPE JOINT COMPOUND OR PIPE JOINT TAPE (TEFLON) ON MALE THREADS AND TIGHTEN JOINT TO LEAVE NOT MORE THAN 3 THREADS EXPOSED. 3.03 SOLDER JOINTS A. COMPLY WITH APPLICABLE PROVISIONS OF "COPPER TUBE HANDBOOK" BY CDA. 3.04 HUBLESS CAST -IRON JOINTS A. COMPLY WITH CISFI 310. 3.05 CLEANING, FLUSHING, AND INSPECTING A. GENERAL CLEAN EXTERIOR SURFACES OF INSTALLED PIPING SYSTEMS OF SUPERFLUOUS MATERIALS, AND PREPARE FOR APPLICATION OF SPECIFIED COATINGS (IF ANY). FLUSH OUT PIPING SYSTEMS WITH TEST MEDIA BEFORE PROCEEDING WITH REQUIRED TESTS. INSPECT EACH RUN OF EACH SYSTEM FOR COMPLETION OF JOINTS, SUPPORTS, AND ACCESSORY ITEMS. 1. INSPECT PRESSURE PIPING IN ACCORDANCE WITH PROCEDURES OF ANSI B31. 2. DISINFECT WATER MAINS AND WATER SERVICE PIPING IN ACCORDANCE WITH AWWA C601. 3.06 PIPING TESTS A. GENERAL PROVIDE EQUIPMENT FOR TESTING, TEST BEFORE INSULATION IS INSTALLED, REMOVE CONTROL DEVICES BEFORE TESTING. TEST EACH SECTION OF EACH PIPING SYSTEM INDEPENDENTLY. FILL EACH SECTION WITH WATER, AND TEST PER SECTION 15010 3.04. B. REPAIR PIPING SYSTEMS SECTION WHICH FAIL TEST, BY DISASSEMBLY AND RE- INSTALLATION, USING NEW MATERIALS TO OVERCOME LEAKAGE. DO NOT USE CHEMICALS, STOP -LEAK COMPOUNDS, MASTICS, OR OTHER TEMPORARY REPAIR METHODS. END OF SECTION 15060 SECTION 15100 VALVES PART 1.00 - GENERAL 1.01 DESCRIPTION A. GENERAL REQUIREMENTS DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND OTHER CONDITIONS AND DIVISION 1 - GENERAL REQUIREMENTS SECTIONS, APPLY TO THE WORK SPECIFIED IN THIS SECTION. PART 2.00 - PRODUCTS 2.01 GENERAL A. PROVIDE FACTORY - FABRICATED VALVES RECOMMENDED BY MANUFACTURER FOR USE IN SERVICE INDICATED. PROVIDE VALVES OF TYPES AND PRESSURE RATINGS INDICATED; PROVIDE PROPER SELECTION AS DETERMINED BY INSTALLER TO COMPLY WITH INSTALLATION REQUIREMENTS. PROVIDE SIZES AS INDICATED, AND CONNECTIONS WHICH PROPERLY MATE WITH PIPE, TUBE, AND EQUIPMENT CONNECTIONS. WHERE MORE THAN ONE TYPE IS INDICATED, SELECTION IS INSTALLER'S OPTION. 2.02 BALL VALVES A. SELECT WITH PORT AREA EQUAL TO OR GREATER THAN CONNECTING PIPE AREA, INCLUDE SEAT RING DESIGNED TO HOLD SEALING MATERIAL. COMPLY WITH THE FOLLOWING STANDARDS: 1. BRONZE VALVES: MILWAUKEE "BUTTERBALL" OR EQUAL. 2. MANUFACTURER: CRANE, FAIRBANKS, MILWAUKEE OR NIBCO. 2.03 AUTOMATIC FLOW CCNTROL VALVES PART 3.00 - EXECUTION 3.01 INSTALLATION A. INSTALL VALVES WHERE REQUIRED FOR PROPER OPERATION OF PIPING AND EQUIPMENT, INCLUDING VALVES IN BRANCH LINES WHERE NECESSARY TO ISOLATE SECTIONS OF PIPING. LOCATE VALVES SO AS TO BE ACCESSIBLE AND SO THAT SEPARATE SUPPORT CAN BE PROVIDED WHEN NECESSARY. B. INSTALL VALVES WITH STEMS POINTED UP, IN VERTICAL POSITION DOWNWARD FROM HORIZONTAL PLANE. END OF SECTION 15100 SECTION 15250 MECHANICAL INSULATION PART 1.00 - GENERAL 1.01 GENERAL REQUIREMENTS A. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND OTHER CONDITIONS AND DIVISION 1 - GENERAL REQUIREMENTS SECTIONS, APPLY TO THE WORK SPECIFIED IN THIS SECTION. AT A MINIMUM, INSULATION VALUES SHALL MEET THE REQUIREMENTS OF THE STATE ENERGY CODE, IF APPLICABLE. 1.02 FLAME /SMOKE RATINGS A. PROVIDE COMPOSITE MECHANICAL INSULATION (INSULATION, JACKETS, COVERINGS, SEALER, MASTICS AND ADHESIVES) WITH FLAME SPREAD INDEX AT 25 OR LESS, AND SMOKE DEVELOPED INDEX OF 50 OR LESS, AS TESTED BY ASTM [84 (NFPA 225) METHOD. PART 2.00 - PRODUCTS 2.01 MATERIALS A. GLASS FIBER PIPE INSULATION: ASTM C 1136 & 547 TYPE I. B. GLASS FIBER PIPE FITTING INSULATION: ASTM C 553. 2.02 MANUFACTURERS A. ONE OF THE FOLLOWING: 1. CERTAINTEE) CORP., KNAUF FIBER GLASS, MANVILLE CORP., OWENS- CORNING FIBERGLASS CORP., IMCOA, NOMACO. 02 69 2.03 PIPING INSULATION A. OMIT INSULATION ON EXPOSED PLUMBING FIXTURE RUN -OUTS, (EXCEPT AT HANDICAPPED FIXTURES) FROM FACE OF WALL OR FLOOR TO FIXTURE; ON UNIONS, FLANGES, STRAINERS, FLEXIBLE CONNECTIONS, AND EXPANSION JOINTS. 1. INSULATE THE FOLLOWING COLD PIPING SYSTEMS: A) DOMESTIC COLD WATER AND CONDENSATE DRAIN PIPING. 2. INSULATE THE ABOVE COLD PIPING WITH THE FOLLOWING INSULATION: A) GLASS FIBER, 1" THICK ON ALL PIPE SIZE EXCEPT 1" DIAMETER AND LESS PIPE AND RUNOUTS UP TO 2" DIAMETER PIPE SIZE. 3. INSULATE THE FOLLOWING HOT PLUMBING PIPING SYSTEMS: A) DOMESTIC HOT WATER PIPING. 4. INSULATE THE ABOVE HOT PIPING WITH ONE OF THE FOLLOWING INSULATIONS: A) DOMESTIC FIBERGLASS: 1 THICK FOR UP TO 2" DIAMETER PIPE SIZE AND 1.5" THICK FOR 2 -1/2" DIAMETER AND LARGER PIPE SIZES. 5. PROVIDE ASJ (ALL SERVICE JACKET) ON ALL PIPING, EXCEPT PIPING EXPOSED TO THE OUTSIDE SHALL HAVE AN ALUMINUM JACKET. 6. ALL PLUMBING SYSTEMS SHALL MEET OR EXCEED THE INSULATION REQUIREMENTS OF THE APPLICABLE CALIFORNIA ENERGY CODE. WHERE INSULATION THICKNESS SPECIFIED ARE LARGER THAN THOSE LISTED IN THE ENERGY CODE, THE LARGER VALUES SHALL BE USED. 2.04 DUCT SYSTEM INSULATION A. INSULATE ALL SUPPLY & VENTILATION AIR DUCTWORK WITH FSK GLASS FIBER INSULATION HAVING A MINIMUM INSTALLED R -VALUE OF 7. B. DO NOT WRAP SOUNDUNED DUCT. PART 3.00 - EXECUTION 3.01 INSTALLATION - PIPE AND DUCT INSULATION A. EXAMINE AREAS AND CONDITIONS UNDER WHICH MECHANICAL INSULATION WILL BE INSTALLED. DO NOT PROCEED WITH WORK UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. B. INSTALL INSULATION PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS, AND IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES TO ENSURE THAT INSULATION SERVES ITS INTENDED PURPOSE. C. INSTALL INSULATION ON MECHANICAL SYSTEMS SUBSEQUENT TO TESTING AND ACCEPTANCE OF TESTS. D. CLEAN AND DRY MECHANICAL SURFACES PRIOR TO INSULATING. BUTT INSULATION JOINTS FIRMLY TOGETHER TO ENSURE COMPLETE AND TIGHT FIT OVER SURFACES TO BE COVERED. E. MAINTAIN INTEGRITY OF VAPOR - BARRIER JACKETS ON MECHANICAL INSULATION, AND PROTECT TO PREVENT PUNCTURE OR OTHER DAMAGE. F. COVER VALVES, FITTINGS AND SIMILAR ITEMS IN EACH PIPING SYSTEM WITH EQUIVALENT THICKNESS AND COMPOSITION OR EFFICIENCY OF INSULATION AS APPLIED TO ADJOINING PIPE RUN. G. EXTEND MECHANICAL INSULATION WITHOUT INTERRUPTION THROUGH WALLS, FLOORS AND SIMILAR PIPING PENETRATIONS, EXCEPT WHERE OTHERWISE INDICATED. H. INSTALL PROTECTIVE METAL SHIELDS AND INSULATED SADDLES TO PREVENT COMPRESSION OF INSULATION. I. REPAIR DAMAGED SECTIONS OF EXISTING MECHANICAL INSULATION, DAMAGED DURING THIS CONSTRUCTION PERIOD. USE INSULATION OF SAME THICKNESS AS EXISTING INSULATION, INSTALL NEW JACKET LAPPING AND SEALED OVER EXISTING. END OF SECTION 15250 SECTION 15401 WATER PIPING PART 1.00 - GENERAL 1.01 GENERAL REQUIREMENTS A. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND OTHER CONDITIONS AND DIV 1 - GENERAL REQUIREMENTS SECTIONS, APPLY TO THE WORK SPECIFIED IN THIS SECTION. 1.02 COMPLIANCE A. COMPLY WITH APPLICABLE PLUMBING CODE STANDARDS PERTAINING TO MATERIALS, PRODUCTS, AND INSTALLATION OF DOMESTIC WATER PIPING. COMPLY WITH APPLICABLE PLUMBING AND MECHANICAL CODE STANDARDS PERTAINING TO MATERIALS, PRODUCTS, AND INSTALLATION OF PROCESS WATER PIPING (INCLUDING CONDENSER WATER). PART 2 - PRODUCTS 2.01 GENERAL A. BASIC PIPING MATERIALS AND PRODUCTS REQUIRED FOR WORK OF THIS SECTION, ARE SPECIFIED IN DIVISION -15 BASIC MATERIALS AND METHODS SECTIONS. PROVIDE PRODUCTS OF SIZES, RATINGS, AND CHARACTERISTICS INDICATED, WHICH COMPLY WITH MANUFACTURER'S STANDARD MATERIALS, DESIGN, AND CONSTRUCTION IN ACCORDANCE WITH PUBLISHED PRODUCT INFORMATION; PROVIDE PROPER QUANTITY OF PIPING AND EQUIPMENT AS REQUIRED FOR COMPLETE INSTALLATION. 2.02 PIPE, TUBE AND FITTINGS A. DOMESTIC WATER PIPING 1. COPPER TUBE: TYPE L HARD -DRAWN TEMPER; WROUGHT - COPPER FITTINGS; SOLDERED JOINTS WITH 95 -5 SOLDER. 2.03 PIPING SPECIALTIES A. PIPE ESCUTCHEONS INSTALL ON EACH PIPE PENETRATION EXPOSED TO VIEW IN OCCUPIED SPACES. B. DRIP PANS INSTALL UNDER PIPES PASSING OVER ELECTRICAL EQUIPMENT. C. SUPPORTS, ANCHORS, AND SEALS D HANGERS, SUPPORTS, - PROVIDE FACTORY FABRICATE_ HANGER_ ORTS AND ANCHOR COMPLYING WITH MSS SP 69. INSTALL COMPLYING WITH MSS SP -89. PART 3.00 - EXECUTION 3.01 PIPING RUNOUTS TO FIXTURES A. PROVIDE HOT AND COLD WATER PIPING RUNOUTS TO FIXTURES OF SIZES INDICATED, BUT IN NO CASE SMALLER THAN REQUIRED BY THE PLUMBING CODE, 3.02 MECHANICAL EQUIPMENT CONNECTION A. CONNECT HOT AND COLD WATER PIPING SYSTEM TO MECHANICAL EQUIPMENT AS INDICATED, AND COMPLY WITH EQUIPMENT MANUFACTURER'S INSTALLATION INSTRUCTIONS. PROVIDE SHUTOFF VALVE AND UNION FOR EACH CONNECTION, PROVIDE DRAIN VALVE ON DRAIN CONNECTION. END OF SECTION 15401 SECTION 15405 SOIL & WASTE PIPING SYSTEM PART 1.00 - GENERAL 1.01 GENERAL REQUIREMENTS A. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND OTHER CONDITIONS AND DIVISION 1 - GENERAL REQUIREMENTS SECTIONS, APPLY TO THE WORK SPECIFIED IN THIS SECTION. 1.02 STANDARDS A. COMPLY WITH APPLICABLE PLUMBING CODE STANDARDS PERTAINING TO MATERIALS, PRODUCTS, AND INSTALLATION OF DRAINAGE PIPING AND EQUIPMENT. B. COMPLY WITH APPLICABLE PDI STANDARDS PERTAINING TO PRODUCES AND INSTALLATION OF SOIL AND WASTE PIPING SYSTEMS. PART 2.00 - PRODUCTS 2.01 GENERAL A. BASIC PIPING MATERIALS AND PRODUCTS REQUIRED FOR THIS SECTION, ARE SPECIFIED IN DIVISION 15 PIPE, TUBE & FITTINGS SECTION. PROVIDE PRODUCTS OF TYPES, SIZES, RATINGS, AND CHARACTERISTICS INDICATED, WHICH COMPLY WITH MANUFACTURER'S STANDARD MATERIALS, DESIGN, AND CONSTRUCTION IN ACCORDANCE WITH PUBLISHED PRODUCT INFORMATION; PROVIDE PROPER QUANTITY OF PIPING AND EQUIPMENT AS REQUIRED FOR COMPLETE INSTALLATION. 2.02 PIPES, TUBES AND FITTINGS GENERAL: PROVIDE ONE OF THE FOLLOWING SELECTIONS AT INSTALLER'S OPTION A. ABOVE GROUND BUILDING PIPING AND FITTINGS: 1. CAST -IRON HUB - AND - SPIGOT SOIL PIPE: SERVICE WEIGHT, CAST IRON HUB - AND - SPIGOT SOIL PIPE FITTINGS WITH COMPRESSION GASKETS. 2. CAST -IRON HUBLESS SOIL PIPE: SERVICE WEIGHT CAST -IRON HUBLESS SOIL PIPE FITTINGS; HUBLESS JOINTS. B. UNDERGROUND BUILDING DRAIN PIPING 1. CAST -IRON HUB - AND - SPIGOT SOIL PIPE FITTINGS, COMPRESSION GASKETS. 2. CAST -IRON HUBLESS SOIL PIPE: SERVICE WEIGHT; CAST -IRON HUBLESS SOIL PIPE FITTINGS; HUBLESS JOINTS. C SUPPORTS, ANCHORS AND SEALS PROVIDE FACTORY- FABRICATED HANGERS, SUPPORTS AND ANCHORS COMPLYING WITH MSS SP -69. INSTALL, COMPLYING WITH MSS SP -89. D. DRAINAGE PIPING PRODUCTS 1. CLEANOUT PLUGS: CAST - BRONZE OR BRASS, THREADS COMPLYING WITH ANSI B2.1, COUNTERSUNK HEAD. INSTALL IN CLEANOUTS AS INDICATED AND AS REQUIRED BY THE PLUMBING CODE. E. FLOOR CLEANOUTS CAST -IRON BODY AND FRAME; ADJUSTABLE ROUND TOP AS FOLLOWS: 1. NICKEL - BRONZE TOP: PATTERN TO SUIT ADJACENT FLOOR FINISH. INSTALL IN OCCUPIED AREAS. 2. CAST -IRON TOP: PATTERN TO SUIT ADJACENT FLOOR FINISH. INSTALL IN UNOCCUPIED AREAS. F. WALL CLEANOUTS CAST -IRON BODY ADAPTABLE TO PIPE WITH CLEANOUT PLUG, STAINLESS STEEL ROUND COVER AND SCREW. G. DRAINAGE PIPING PRODUCTS MANUFACTURER JOSAM, SMITH, WADE OR ZURN. H. FLOOR DRAINS: AS SPECIFIED ON DRAWINGS. PROVIDE TRAP PRIMER CONNECTION. 11.ECEIVED APR 012006 PERMIT CENTER COPYRIGHT 0 2008 CARTER & BURGESS, INC. at &t Carter:Burgess Carter & Burgess, Inc. 4 Hutton Centre Drive, Suite 800 Santa Ana, California 92707 TEL: (714) 327- 1600 FAX: (714) 327 -1601 CODE COMPLIANCE PR VED ApIR City Of TukwNii I, D 1 03 -29 -08 TENANT CHANGES 03 -19 -08 ISSUE FOR PERMIT NO. DATE 16425 Southcenter Parkway T U KW I LA, WA DESIGNED BY: KL CHECKED BY: MV DRAWN BY: KL PROJECT NUMBER: SCALE: 1 EXPIRES 03/15/10 ISSUES /REVISIONS DESCRIPTION MECHANICAL AND PLUMBING SPECIFICATIONS APPROVED BY: MV 441805.011.039.0001 NONE M -003 PART 3.00 - EXECUTION 3.01 GENERAL A. EQUIPMENT CONNECTIONS PROVIDE SOIL AND WASTE PIPING RUNOUTS TO PLUMBING FIXTURES AND DRAINS, WITH APPROVED TRAP, OR SIZES INDICTED; BUT IN NO CASE SMALLER THAN REQUIRED BY THE LOCAL PLUMBING CODE. B. LOCATE PIPING RUNOUTS AS CLOSE AS POSSIBLE TO BOTTOM OF FLOOR SLAB SUPPORTING FIXTURES OR DRAINS. C. TEST SOIL AND WASTE PIPING SYSTEM IN ACCORDANCE WITH REQUIREMENTS OF LOCAL PLUMBING CODES. D. COORDINATE WITH SOIL AND WASTE PIPING AS NECESSARY TO INTERFACE FLOOR DRAINS WITH DRAINAGE PIPING SYSTEMS. E. INSTALL FLOOR DRAINS IN ACCORDANCE WITH WRITTEN MANUFACTURER'S INSTRUCTIONS, AT LOW POINTS OF SURFACE AREAS TO BE DRAINED, OR AS INDICATED. SET TOPS OF DRAINS FLUSH WITH FINISHED FLOOR. COORDINATE WITH ARCHITECTURAL DRAWINGS. F. INSTALL DRAIN FLASHING COLLAR OR FLANGE SO THAT NO LEAKAGE OCCURS BETWEEN DRAIN AND ADJOINING FLOORING. MAINTAIN INTEGRITY OF WATERPROOF MEMBRANES, WHERE PENETRATED. 3.02 SEWER LINES A. INSTALLATION INSTALL UNDERGROUND BUILDING DRAINS AS INDICATED AND IN ACCORDANCE WITH THE PLUMBING CODE. LAY UNDERGROUND BUILDING DRAINS BEGINNING AT LOW POINT OF SYSTEMS, TRUE TO GRADES AND ALIGNMENT INDICATED WITH UNBROKEN CONTINUITY OF INVERT. PLACE BELL ENDS OF PIPING FACING UPSTREAM. INSTALL REQUIRED GASKETS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS FOR USE OF LUBRICANTS, CEMENTS, AND OTHER SPECIAL INSTALLATION REQUIREMENTS. OUS MATERIAL AS WORK PROGRESSES. MAINTAIN SWAB OR DRAG IN CLEAN INTERIOR OF PIPING OF DIRT AND OTHER SUPERFL U MATE _ R L A W R LINE AND PULL PAST EACH JOINT AS IT IS COMPLETED. PLACE PLUGS IN ENDS OF UNCOMPLETED PIPING AT END OF DAY OR WHENEVER WORK STOPS. B. INSTALL SOIL AND VENT PIPING PITCHED TO DRAIN AT MINIMUM SLOPE OF 1/4" PER FOOT (2%) AND 1/8" PER FOOT WHERE INDICATED ON DRAWINGS. VENT PIPING MAY BE INSTALLED HORIZONTAL IF REQUIRED TO AVOID CONFLICT WITH BUILDING ELEMENTS. C. PROVIDE TRAP PRIMER AT ALL FLOOR DRAINS. TRAP PRIMERS SHALL HAVE EASY MAINTENANCE ACCESS. D. CONDENSATE DRAIN PIPING SHALL BE PVC, UNLESS LANDLORD REQUIRES COPPER PER TENANT CRITERIA. 3.03 PIPING SPECIALITIES A. PIPE ESCUTCHEONS: INSTALL ON EACH PIPE PENETRATION EXPOSED TO VIEW IN OCCUPIED SPACES. B. DRIP PANS: INSTALL UNDER PIPES PASSING OVER ELECTRICAL EQUIPMENT. END OF SECTION 15405 SECTION 15410 PLUMBING PART 1.00 - GENERAL 1.01 DESCRIPTION A. GENERAL REQUIREMENTS DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND OTHER CONDITIONS AND DIVISION 1 - GENERAL REQUIREMENTS SECTIONS, APPLY TO THE WORK SPECIFIED IN THIS SECTION. 1.02 WORK INCLUDED A. PROVIDE AND INSTALL ALL PLUMBING FIXTURES AND EQUIPMENT SPECIFIED HEREIN AND INDICATED ON THE DRAWINGS. 1.03 SUBMITTALS A. SUBMIT MANUFACTURER'S TECHNICAL PRODUCT DATA, ASSEMBLY -TYPE SHOP DRAWINGS, AND MAINTENANCE DATA, IN ACCORDANCE WITH SECTION 01300 IF SUBMITTING AS APPROVED EQUAL. PART 2.00 - PRODUCTS 2.01 PLUMBING FIXTURES A. PROVIDE ALL PLUMBING FIXTURES INDICATED AND SPECIFIED ON DRAWINGS. ALL FAUCETS AND DRINKING FOUNTAINS, ETC., SHALL BE LEAD FREE AS DEFINED BY THE SAFE DRINKING WATER ACT AMENDMENTS FO 1986 AND THE LEAD CONTAMINATION CONTROL ACT OF 1988. CONTAMINATION CONTROL ACT OF 1988. 2.02 ELECTRIC WATER HEATER A. PROVIDE ALL WATER HEATERS INDICATED AND SPECIFIED ON DRAWINGS. 2.03 WATER HAMMER ARRESTOR A. PROVIDE ALL WATER HAMMER ARRESTORS INDICATED AND SPECIFIED ON DRAWINGS. PART 3,00 - EXECUTION 3.01 FIXTURES A. FIXTURES SHALL BE INSTALLED WHERE SHOWN ON PLANS, COMPLETE WITH TRAPS, VALVES, STOPS AND ALL FITTINGS. ALL FIXTURES SHALL BE FIRMLY ANCHORED AGAINST MOVEMENTS. LOCATE IN CENTER OF AREA ALLOWED UNLESS NOTED OTHERWISE. FIXTURES SHALL BE INSTALLED COMPLETE WITH ALL FITTINGS AND NUMBERS SHALL INCLUDE THE FITTINGS AS IF THEY WERE COMPLETELY LISTED AND SPECIFIED WITH EACH FIXTURE. PROVIDE CAULKING BETWEEN WALL AND FIXTURE ON ALL WALL HUNG FIXTURES. USE RESILIENT (FLEXIBLE) PRODUCT SUCH AS GE SILILCONE BATHTUB SEALANT. PROVIDE SEALED WATER HAMMER ARRESTORS ON HW AND CW SUPPLY PIPES AT EACH FIXTURE OR BANK OF FIXTURES. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. B. SEE ARCHITECTURAL PLANS FOR MOUNTING HEIGHTS OF ALL FIXTURES NOT NOTED IN THIS SPECIFICATION. COMPLY WITH HANDICAPPED ACCESSIBILITY CODE REQUIREMENTS. C. TRAP PRIMERS SHALL BE EASILY ACCESSIBLE. PROVIDE ACCESS PANEL IN WALL. END OF SECTION 15410 SECTION 15820 AIR DISTRIBUTION EQUIPMENT PART 1.00 - GENERAL 1.01 GENERAL REQUIREMENTS A. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND OTHER CONDITIONS AND DIVISION 1 - GENERAL REQUIREMENTS SECTIONS, APPLY TO THE WORK SPECIFIED IN THIS SECTION. 1.02 COMPLIANCE A. AMCA COMPLIANCE: TEST AND RATE AIR DISTRIBUTION EQUIPMENT IN ACCORDANCE WITH AMCA STANDARDS, AND PROVIDE AMCA CERTIFIED RATINGS SEAL. B. UL COMPUANCE: PROVIDE ELECTRICAL COMPONENTS OF AIR DISTRIBUTION EQUIPMENT WHICH HAVE BEEN LISTED AND LABELED BY UL 1.03 SUBMITTALS A. SUBMIT MANUFACTURER'S TECHNICAL PRODUCT DATA OF APPROVED EQUALS (SUBMITTALS ARE NOT REQUIRED IF PRODUCT MATCHES SPECIFIED ITEMS ON DRAWINGS), ASSEMBLY - TYPE SHOP DRAWINGS, LADDER -TYPE WIRING DIAGRAMS DIFFERENTIATING BETWEEN PORTIONS OF WIRING THAT ARE FACTORY INSTALLED AND PORTIONS TO BE HELD-INSTALLED, AND MAINTENANCE DATA. PART 2,00 - PRODUCTS 2.01 HVAC SYSTEMS A. PROVIDE EQUIPMENT AS SCHEDULED WITH ALL OPTIONS AS DESCRIBED ON THE MECHANICAL SCHEDULES ON THE MECHANICAL DRAWINGS. B. WHEREVER POSSIBLE, PROVIDE BELT DRIVEN EQUIPMENT AS SCHEDULED OR PROVIDED BY THE MANUFACTURER WITH ALL OPTIONS INCLUDED IN THE SCHEDULES OR REQUIRED TO MEET THE PERFORMANCES NOTED ON THE MECHANICAL DRAWINGS. PART 3.00 - EXECUTION 3.01 INSTALLATION A. UNITS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, INSTRUCTIONS AND DETAILS ON DRAWINGS. B. ALL EXHAUST FAN SYSTEMS TO HAVE BACKDRAFT OR MOTORIZED DAMPERS IN THE SYSTEM. C. PROVIDE FLEXIBLE DUCT CONNECTIONS TO ALL FANS. D. PROVIDE ROOF CURBS FOR ALL ROOF HOODS, ROOF MOUNTED EQUIPMENT AND DUCT PENETRATIONS THRU ROOF. E. PROVIDE FACTORY AUTHORIZED STARTUP OF ALL EQUIPMENT. END OF SECTION 15820 SECTION 15840 DUCTWORK PART 1.00 - GENERAL 1.01 DESCRIPTION A. GENERAL REQUIREMENTS DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND CONDITIONS AND DIVISION 1 - GENERML REQUIREMENTS SECTIONS, APPLY TO THE WORK SPECIFIED IN THIS SECTION. 1.02 WORK INCLUDED A. INCLUDE ALL LABOR, MATERIALS, EQUIPMENT TRANSPORTATION AND SERVICES TO FURNISH AND INSTALL COMPLETE ALL DUCTWORK AND RELATED SYSTEMS SPECIFIED HEREIN AND INDICATED ON THE DRAWING. PART 2.00 - PRODUCTS 2.01 SHEETMETAL WORK A. FURNISH ALL DUCTWORK AS SHOWN ON PLL■NS. ALL DUCTWORK CONSTRUCTION SHALL COMPLY WITH SMACNA STANDARDS AND LOCAL MECHANICAL CODE STANDARDS, WHICHEVER IS MORE STRINGENT. DUCT CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE FOLLOWING PRESSURE VELOCITY CLASSIFICATIONS FOUND IN SMACNA HVAC DUCT CONSTRUCTION STANDARDS, FIRST EDITION (1985). 1. DUCTWORK BETWEEN VAV AIR HANDLING UNITS AND TERMINAL BOXES: MAXIMUM +6" W.G., 4,000 F.P.M., VARIABLE AIR VOLUME. DOWNSTREAM 0 TERMINAL BOXES: +2"W.G., 2 500 F.P.M. VARIABLE AIR VOLUME. 2. DUCTWORK __ OF F.P.M., 3. EXHAUST DUCTWORK (ALL EXHAUST FAN SYSTEMS WHERE DESIGN FAN STATIC IS LISTED AT 1.0" W.G. OR ABOVE): +2" TO -2"W.G., 2500 F.P.M., CONSTANT VOLUME. 4. RETURN, RELIEF OR EXHAUST DUCTWORK WHERE FAN DESIGN STATIC IS LISTED BELOW 1.0"W.G.: +1" TO -1" W.G., 2,500 F.P.M., CONSTANT VOLUME. 5. SUPPLY DUCTS NOT LISTED ABOVE: +2" TO -2" W.G., 2,500 F,P.M., CONSTANT VOLUME. 6. TRANSFER DUCTS: +0.5" TO -0.5" W.G., 2,000 F.P.M., CONSTANT VOLUME. B. PRIOR TO ANY FABRICATING OF SHEET METAL WORK, THE MECHANICAL CONTRACTOR SHALL CAREFULLY MEASURE (AT THE SITE) AVAILABLE SPACE FOR SHEET METAL WORK. HE SHALL PREPARE LARGE SCALE SHOP DRAWINGS OF SHEET METAL WORK SHOWING ALL OTHER ELEMENTS OF THE BUILDING INCLUDING PIPING, STRUCTURAL AND ELECTRICAL SO ALL ARE COORDINATED AND FIT AVAILABLE SPACE, THE SHOP DRAWINGS WILL NOT GO THROUGH A FORMAL SUBMITTAL PROCESS, BUT 2 COPIES SHALL BE GIVEN TO THE ARCHITECT AS EVIDENCE OF THEIR BEING COMPLETED. C. LONGITUDINAL SEAMS IN DUCTS SHALL BE FLAT, DOUBLE LOCK TYPE. S AND DRIVE TYPE. D. TRANSVERSE SEAMS SHALL BE OF TYPE AND SPACING AS FOLLOWS: MAX. SIDE TYPE SPACING UP TO 30" DRIVE SUP 7' -10" 31" TO 60" 1 -1/2" POCKET SUP 7' -10" 61" AND UP 1 -1/2" POCKET SLIP 3'- 9" CROSS BREAK PANELS 18" AND OVER IN WIDTH. E. STANDING SEAMS ARE NOT ACCEPTABLE ON ANY DUCTWORK. F. JOINT LOCKING: THE SLIPJOINT IN POCKET SLIP SEAMS SHALL BE SCREWED USING NOT LESS THAN ONE SCREW PER FACE AND MAXIMUM SPACING OF 2' -0 ". G. DAMPERS PROVIDE DAMPERS AND QUADRANTS IN DUCTWORK AS NECESSARY FOR BALANCING. PROVIDE ONE DAMPER IN THE DUCT LEADING TO EACH SUPPLY OR RETURN /EXHAUST OPENING. DAMPERS SHALL BE LOCATED IN AN ACCESSIBLE LOCATION. DAMPERS SHALL BE FITTED WITH PARKER KALON DAMPER BEARINGS AND PARKER KALON NO, 195T QUADRANTS. DAMPERS SHALL BE OF 20 GA. G.I. SINGLE PLATE TYPE WITH EDGES HEMMED. FOR DAMPERS ABOVE "HARD" (GYPBOARD OR NON- ACCESSIBLE) CEILINGS, PROVIDE BOWDEN CABLE CONTROLLER WITH CONCEALED OPERATORS IN NEAREST RETURN GRILLE. SHOW LOCATION OF ALL REMOTE DAMPER OPERATORS & VOLUME DAMPERS ON RECORD DRAWINGS. INCLUDE DRAWING W /BALANCING REPORT. ADUSTABLE SPLITTER DAMPERS TO BE YOUNG REGULATOR 8908. H. ACCESS DOORS SHALL BE PROVIDED BY THIS CONTRACTOR IN FINISHED WALLS AND CEILINGS WHERE REQUIRED TO REACH MECHANICAL EQUIPMENT, MILCOR OR EQUAL. I. INSULATED LOW PRESSURE FLEXIBLE DUCT SHALL BE A FACTORY FABRICATED ASSEMBLY CONSISTING OF A ZINC - COATED SPRING STEEL HELIX, NON- PERFORATED INNER LINER, WRAPPED WITH A NOMINAL 1 THICK BY 1 LB /CU. FT. DENSITY FIBERGLASS INSULATION. THE ASSEMBLY SHALL BE SHEATHED IN A VAPOR BARRIER JACKET, FACTORY SEALED AT BOTH ENDS OF EACH SECTION, THUS ASSURING THE VAPOR RESISTANCE OF EACH SECTION AS WELL AS THE COMPLETED INSTALLATION. THE COMPOSITE ASSEMBLY INCLUDING INSULATION AND VAPOR BARRIER SHALL MEET THE CLASS 1 REQUIREMENTS OF NFPA BULLETIN NO. 90 -A AND BE LABELED BY UL WITH A FLAME SPREAD RATING OF 25 OR LESS AND A SMOKE DEVELOPED RATING OF 50 OR UNDER. FLEXIBLE DUCTS SHALL BE INSTALLED IN A FULLY EXTENDED LENGTH REQUIRED TO MAKE THE CONNECTION. WHERE HORIZONTAL SUPPORT IS REQUIRED, FLEXIBLE DUCT SHALL BE SUSPENDED ON 36" CENTERS WITH A MINIMUM 3/4" WIDE FLAT BANDING MATERIAL. ALL JOINTS AND CONNECTIONS SHALL BE MADE WITH 1/2" WIDE POSITIVE LOCKING STEEL STRAPS. INSULATED LOW PRESSURE FLEXIBLE DUCT SHALL BE GREENFLEX TYPE SL -1 OR EQUAL. PROVIDE SPIN -IN FITTINGS FOR CONNECTION TO TRUCK DUCT. MAXIMUM LENGTH OF FLEX DUCT 5 5 FEET WITH ONE 90 DEGREE BEND. J. OFFSETS PROVIDE OFFSETS AND TRANSITIONS AS REQUIRED TO FIT DUCTWORK INTO AVAILABLE SPACE. MAINTAIN EQUIVALENT FREE AREA OF DUCTWORK, AND TRANSITION SHALL BE SMOOTH (LESS THAN 15 DEGREES). 2.02 DUCT LINING A. JOHNS MANSVILLE 1 THICK 1.5 LB /CU.FT. DENSITY (WHERE CALLED OUT ON DRAWINGS AND OR WHERE SPECIFIED) LINACOUSTIC R -4 MIN. OR 1.5" THICK 1.5 LB /CU.FT. DENSITY LINACOUSTIC R -5 MIN. WHERE "SOUNDLINED" OR "LINED" DUCT IS CALLED OUT ON DRAWINGS OR SPECIFIED. SERVICE WITH GLUE AND CLIPS. SPACE CLIPS A MAXIMUM OF 18 "0.C. LINE ALL RECTANGULAR DUCTS (INCLUDES OUTSIDE AIR, SUPPLY, RETURN, EXHAUST AND TRANSFER DUCTS). THE NET FREE AREA OF THE DUCT DIMENSIONS GIVEN ON THE DRAWINGS SHALL BE MAINTAINED. INCREASE METAL DUCT DIMENSIONS AS NECESSARY TO COMPENSATE FOR ADDITION OF THE LINER. B. THE DUCT LINER SHALL BE APPLIED WITH 100% COVERAGE OF APPROVED FIRE RESISTANT ADHESIVE. LINER SHALL BE ADDITIONALLY SECURED WITH MECHANICAL FASTENERS ON MAXIMUM 15" CENTERS. FASTENERS SHALL START WITHIN 2" OF THE LEADING EDGE OF EACH SECTION AND WITHIN 3" OF THE LEADING EDGE OF ALL CROSS JOINTS WITHIN THE DUCT SECTION. ALL EXPOSED EDGES AND THE LEADING EDGE OF ALL CROSS JOINTS OF THE LINER SHALL BE HEAVILY COATED WITH AN APPROVED FIRE RESISTANT ADHESIVE. THE DUCT LINER SHALL BE CUT TO ASSURE SNUG CLOSING CORNER JOINTS, THE BLACK SURFACE OF THE LINER SHALL FACE THE AIR STREAM, TRANSVERSE JOINTS SHALL BE NEATLY BUTTED, AND ANY DAMAGED AREAS SHALL BE HEAVILY COATED WITH AN APPROVED FIRE RESISTANT ADHESIVE. 2.03 BACKDRAFT DAMPERS A. GENERAL PROVIDE DAMPERS AT ALL OUTSIDE AIR AND RELIEF DUCTS INTAKING OR EXHAUSTING TO ATMOSPHERE. B. TYPE 1. BACKDRAFT DAMPERS ON FAN SYSTEMS SHALL BE GALVANIZED STEEL OR ALUMINUM MULTIBLADE TYPE. BLADES SHALL HAVE FELT STRIPS RIVETED OR CRIMPED IN PLACE. BLADES SHALL BE JOINED TOGETHER WITH CONNECTION BARS. EACH BLADE SHALL BE RIGIDLY ATTACHED TO A PIVOT ROD. THE ROD SHALL EXTEND INTO OIL- IMPREGNATED BRONZE BUSHINGS, OR ANTIFRICTION BEARINGS, LOCATED IN THE FRAMES. RUSKIN CBD2 OR EQUAL. 2. FABRIC BACKDRAFT DAMPERS ON RELIEF DUCTS SHALL BE CONSTRUCTED TO INDUSTRY STANDARDS. C. MANUFACTURER 2.04 LOUVERS A. FURNISH WONDER METAL MODEL 'SDL -4" DRAINABLE FORMED GALVANIZED STEEL STORM -PROOF MULLION NON- MECHANICAL FIXED WALL LOUVERS, OR AIR LOUVERS INC., THE AIROLTTE CO., CONSTRUCTION SPECIALTIES INC., RUSKIN, OR INDUSTRIAL LOUVERS INC. EQUIVALENT, OR APPROVED; SIZES AND CONFIGURATIONS AS SHOWN, COMPLETE WITH FLAT BAR ORNAMENTAL SHAPES WERE SHOWN; REFER TO EXTERIOR BUILDING ELEVATIONS AND LOUVER SCHEDULE, SECTION 22 OF PROJECT MANUAL VOLUME II. PROVIDE WITH BIRD SCREEN AND COLOR AS DESIGNATED BY ARCHITECT. B. LOUVERS SHALL HAVE BEEN TESTED AND RATED TO HAVE MINIMUM 45% FREE OPENING BASED ON A 4X4 FOOT SIZE LOUVER. C. FRAME AND BLADES TO BE 16 GAUGE GALVANIZED STEEL. D. HEADS, SILLS AND JAMBS TO BE ONE PIECE STRUCTURAL MEMBERS AS DETAILED AND SECURELY ANCHOR TO WALL CONSTRUCTION AS APPROVED. E. SLIDEABLE INTERLOCKED MULLIONS TO HAVE PROVISION TO EXPANSION AND CONTRACTION. F. FURNISH COMPLETE WITH MANUFACTURER'S STANDARD BIRD SCREEN MOUNTED IN FOLDED "U" TYPE FRAME AND ATTACH TO INSIDE FACE OF LOUVER FRAME WITH STEEL SCREWS AT ACTIVE (OPEN) PORTIONS OF LOUVERS AND WITH 20 GAUGE GALVANIZED STEEL FACED INSULATED 'BLANK -OFF' PANELS AT INACTIVE LOUVER AREAS, COMPLETE WITH PERIMETER GASKETS AND FINISHED TO MATCH LOUVER. INSULATION CORE SHALL BE 1 INCH THICK EXTRUDED POLYSTRYENE HAVING A MINIMUM THERMAL RESISTANCE "R" VALUE OF 5.0. G. ALL LOUVERS TO BE FREE OF SCRATCHES AND BLEMISHES AND SHALL BE FINISH PAINTED WITH BAKED -ON ENAMEL POWDER COATING. 2.05 FIRE DAMPERS A. DYNAMIC FIRE DAMPERS SHALL BE CONSTRUCTED AND TESTED IN ACCORDANCE WITH UL SAFETY STANDARD 555. EACH DAMPER SHALL HAVE A 1 1/2 HOUR RATING WITH 165 DEGREE F FUSABLE LINK AND BE LABLED PER UL 555 STANDARD. B. DYNAMIC COMBINATION FIRE /SMOKE DAMPERS,RUSKIN FSD36, SHALL BE CONSTRUCTED OF MIN. 16 GAUGE GALVANIZED STEEL WITH STAINLESS STEEL BEARINGS, JAMB SEALS AND 450 DEG. F RATED BLADE EDGE SEAL. DAMPERS SHALL BE 1 HR. RATED UNDER UL STANDARD 555 AND UL 5555. ALL DAMPERS USED UNDER THIS SPECIFICATION MUST BE UL TESTED & QUALIFIED IN THE COMPLETE RANGE OF SIZES USED. A SINGLE DAMPER TESTED WITHIN THIS RANGE IS NOT ACCEPTABLE. LEAKAGE RATING SHALL BE CLASS 11. INCLUDE A UL CLASSIFIED FIRE STAT. FIRESTAT SHALL ELECTRICALLY AND MECHANICALLY LOCK DAMPER CLOSED WHEN DUCT TEMPERATURE EXCEEDS 165 DEG. F. DAMPER MUST BE OPERABLE ABOVE 250 DEG. F. FIRESTAT SHALL BE EQUIPPED WITH TWO DAMPER POSITION INDICATORS FOR REMOTE INTERFACING WITH SMOKE DETECTORS & FIRE ALARM SYSTEM. ALSO PROVIDE INTEGRAL FLOW RATED DUCT SMOKE DETECTORS FOR DUCTED FIRE/ SMOKE DAMPERS AND NO -FLOW DUCT SMOKE DETECTORS FOR NON- DUCTED FIRE SMOKE DETECTORS. C. CEIUNG FIRE DAMPERS SHALL BE INSTALLED IN ALL CEILING REGISTERS AND GRILLES. IN THE RATED CEILING. FIRE DAMPERS CONSIST OF A RADIANT DAMPER IN THE DIFFUSER NECK AND THERMAL INSULATING BLANKET COVERING THE DIFFUSER PAN. THE ENTIRE SYSTEM SHALL BE UL RATED FOR FLOOR /CEILING AND ROOF /CEILING SYSTEM. PART 3.00 - EXECUTION 3.01 SHEET METAL WORK A. PARTITIONS FORMING PLENUMS OR CASINGS SHALL BE #18 GA., WITH GALVANIZED IRON ANGLES AND RIVETS FOR SEAM CONNECTION AND STIFFENING. ALL JOINTS AND STANDING SEAMS SHALL BE SEALED WITH APPROVED DUCT SEALANT. B. CORK GASKETS SHALL BE INSTALLED BETWEEN ALL CONNECTIONS OF SHEET METAL TO COIL AND FILTER CASINGS. C. SHEET METAL CONNECTIONS OF PLENUMS AND AIR CHAMBERS TO WALL AND FLOORS SHALL BE MADE WITH GALVANIZED ANGLES ANCHORED TO WALL OR FLOOR CONSTRUCTION WITH ANCHOR BOLTS WITH SHEET METAL BOLTED OR RIVETED TO ANGLES. MASTIC SEALER SHALL BE INSTALLED AT CONNECTION OF ANGLES TO SHEET METAL TO PROVIDE AIR -TIGHT JOINTS. PROVIDE ACCESS DOORS IN PLENUMS AND CHAMBERS WITH HANDLES OPERATED FROM BOTH SIDES, VENTLOCK NO. 205 OR APPROVED SUBSTITUTE. D. HINGED ACCESS DOORS IN SHEET METAL DUCT FOR ACCESS TO DAMPERS SHALL BE #18 GA., FRAMED WITH STEEL ANGLE AND HEMMED EDGES. E. CONNECT ALL GRILLES TO DUCTWORK. PAINT THE INSIDE OF THE DUCT A DULL BLACK AT ALL GRILLES. F. ALL AIR INLETS AND OUTLETS TO OUTSIDE SHALL HAVE BIRDSCREENS. BACKDRAFT DAMPER SHALL BE PROVIDED WHERE MOTORIZED DAMPER IS NOT INDICATED. G. ALL DUCTS THROUGH ROOF SHALL BE FLASHED WATER - TIGHT. SEE DETAIL. ALL DUCTS THRU WALLS AND FLOORS /ROOFS SHALL HAVE ANGLE ENCLOSURES. H. CONNECTIONS OF ALL DUCTS TO ALL EQUIPMENT SHALL BE MADE WITH NEOPRENE. I. ELBOWS SHALL HAVE AN INSIDE RADIUS EQUAL TO 1/2 THE DUCT WIDTH. RECTANGULAR ELBOWS SHALL HAVE DUCT TURNS, T &B OR APPROVED EQUAL. USE RECTANGULAR ELBOWS WHEREVER A ROUND ELBOW CANNOT BE USED AND WHERE SHOWN ON DRAWINGS. SQUARE INSIDE ELBOW AND ROUND OUTSIDE ELBOW ARE NOT PERMITTED. DO NOT INSTALL TURNING VANES IN GREASE EXHAUST DUCTWORK. J. SUPPORTERS SHALL BE GALVANIZED STRAP OR ANGLE IRON HANGERS, ARRANGED TO PREVENT ANY BULGING, BENDING, OR SAGGING OF DUCTWORK. UNDER NO CONDITION SHALL HANGERS PIERCE THE DUCTS. VERTICAL DUCTS SHALL BE SUPPORTED AT EACH FLOOR WITH 18 GA. FORMED ANGLE. K. SEAL ALL DUCT JOINTS WITH APPROVED DUCT SEALANT. L HANGERS 1. PROVIDE HANGERS AND SEISMIC RESTRAINTS ON ALL DUCTWORK. 2. HANGERS FOR CIRCULAR DUCTS AND TUBING: A #18 GAUGE GALVANIZED SHEET STEEL STRAP SHALL BE WRAPPED AROUND THE DUCT AT EACH POINT OF SUPPORT. FOR CONCEALED WORK THIS STRAP SHALL BE BOLTED TO A STRAP HANGER OF SIMILAR GAUGE AND WIDTH; FOR EXPOSED WORK, BOLTED TO A STEEL ROD HANGER IN EACH CASE, ROD HANGER 1/4" SIZE FOR DUCTS UP TO 10" SIZE, 3/8" SIZE FOR LARGER DUCTS. WIDTH OF GALVANIZED STEEL STRAP WRAPPED AROUND THE DUCT SHALL NOT BE LESS THAN 1" IN ANY CASE; WHERE DUCTS ARE IN EXCESS OF 10" IN DIAMETER SHALL BE 2 ". 3. SPACING OF HANGERS SHALL NOT EXCEED 10' -0" ON CENTERS IN ANY CASE; WHERE DUCTS ARE INSULATED AND ARE IN EXCESS OF 10" IN SIZE, SPACING SHALL NOT EXCEED 8' -0 ". M. A MAXIMUM OF 5 FEET LENGTH OF FLEX DUCT WITH ONE 90 DEGREE BEND WILL BE ALLOWED AT CONNECTIONS TO DIFFUSERS, WHERE FLEX DUCT IS SHOWN ON DRAWINGS. N. PROVIDE FIRE STOP AROUND DUCTWORK AT ALL DUCT PENETRATION OF RATED CONSTRUCTION. "FIRE STOP SEALANT" BY DOW CORNING. 0. BACKDRAFT DAMPERS ON RELIEF DUCTS SHALL BE METAL BLADE TYPE. P. PROVIDE DUCT TRANSITIONS AS REQUIRED TO SOUND TRAPS AND ALL EQUIPMENT CONNECTIONS. Q. PROVIDE DUCT LINING ON RECTANGULAR DUCTS WHERE INDICATED ON DRAWINGS (OUTSIDE AIR, SUPPLY, RETURN, EXHAUST AND TRANSFER AIR DUCTS). THE NET FREE AREA OF THE DUCT DIMENSION GIVEN ON THE DRAWINGS SHALL BE MAINTAINED. INCREASE METAL DUCT DIMENSIONS AS NECESSARY TO COMPENSATE FOR ADDITION OF THE LINER. R. ALL DUCTWORK, INCLUDING, BUT NOT LIMITED TO DUCTS, HANGERS, BRACKETS, FITTINGS AND JOINTS, SHALL BE INSTALLED IN A MANNER WHICH NEITHER REDUCES HEADROOM AND WALKWAY WIDTH NOR PROJECTS ANY SHARP EDGES INTO A CATWALK OR PASSAGE AREA. ANY DUCTWORK WHICH, IN THE OPINION OF THE ARCHITECT, PRESENTS A POSSIBLE HAZARD TO PEOPLE IN THE CATWALK AREA, SHALL BE CHANGED TO AN ACCEPTABLE AND SAFE MANNER, SUCH CHANGES MAY INCLUDE: MOVING THE EQUIPMENT, CHANGING ITS CONFIGURATION, AND /OR ADDING PROTECTIVE PADDING TO THE EQUIPMENT. S. INTAKE BACKDRAFT DAMPERS SHALL BE INSTALLED AT THE ENVELOPE OF THE BUILDING. T. INSTALL FIRE DAMPERS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. END OF SECTION 15840 SECTION 15870 OUTLETS AND INLETS PART 1.00 - GENERAL 1.01 DESCRIPTION A. GENERAL REQUIREMENTS DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND OTHER CONDITIONS AND DIVISION 1 - GENERAL REQUIREMENTS SECTIONS, APPLY TO THE WORK SPECIFIED IN THIS SECTION. 1.02 COMPLIANCES A. ADC COMPLIANCE TEST AND RATE REGISTERS, GRILLES, AND DIFFUSERS IN ACCORDANCE WITH ADC EQUIPMENT TEST CODE 1062R4, PROVIDE CERTIFIED RATINGS SEAL ON EACH UNIT. B. AMCA COMPLIANCE TEST AND RATE LOLVERS, DAMPERS, AND SHUTTERS IN ACCORDANCE WITH AMCA STANDARD 500, PROVIDE CERTIFIED RATINGS SEAL ON EACH UNIT. 1.03 SUBMITTALS A. SUBMIT MANUFACTURER'S TECHNICAL PRODUCT DATA UNLESS AS SPECIFIED ON DRAWINGS, ASSEMBLY -TYPE SHOP DRAWINGS, AND MAINTENANCE DATA. PART 2.00 - PRODUCTS 2,01 CEILING AIR DIFFUSERS A. GENERAL EXCEPT AS OTHERWISE INDICATED, PROVIDE MANUFACTURER'S STANDARD CEILING AIR DIFFUSERS WITH FIRE DAMPERS; OF SIZE, SHAPE, CAPACITY AND TYPE INDICATED; CONSTRUCTED OF MATERIALS AND COMPONENTS INDICATED AND AS INDICATED ON DRAWINGS FOR COMPLETE INSTALLATION. B. CEILING COMPATIBILITY PROVIDE DIFFUSERS WITH BORDER STYLES THAT ARE COMPATIBLE WITH ADJACENT CEILING SYSTEMS, AND THAT ARE SPECIFICALLY MANUFACTURED TO FIT INTO CEILING MODULE WITH ACCURATE FIT AND ADEQUATE SUPPORT. REFER TO GENERAL CONSTRUCTION DRAWINGS AND SPECIFICATIONS FOR TYPES OF CEILING SYSTEMS WHICH WILL CONTAIN EACH TYPE OF CEILING AIR DIFFUSER. C. TYPES PROVIDE TITUS CEILING DIFFUSERS OF TYPE, CAPACITY, AND WITH ACCESSORIES AND FINISHES AS SCHEDULED. 2.02 REGISTERS AND GRILLES A. GENERAL EXCEPT AS OTHERWISE INDICATED, PROVIDE MANUFACTURER'S STANDARD WALL REGISTERS AND GRILLES WITH FIRE DAMPERS; OF SIZE, SHAPE, CAPACITY AND TYPE INDICATED; CONSTRUCTED OF MATERIALS AND COMPONENTS AS INDICATED ON DRAWINGS, AND AS REQUIRED FOR COMPLETE INSTALLATION. B. PERFORMANCE PROVIDE WALL REGISTERS AND GRILLES THAT HAVE, AS MINIMUM, TEMPERATURE AND VELOCITY TRAVERSES, THROW AND DROP, AND NOISE CRITERIA RATINGS FOR EACH SIZE DEVICE AS LISTED IN MANUFACTURER'S CURRENT DATA. C. COMPATIBILITY PROVIDE REGISTERS AND GRILLES WITH BORDER STYLES THAT ARE COMPATIBLE WITH ADJACENT WALL OR CEILING SYSTEMS, AND THAT ARE SPECIFICALLY MANUFACTURED TO FIT INTO CONSTRUCTION WITH ACCURATE FIT AND ADEQUATE SUPPORT. REFER TO GENERAL CONSTRUCTION DRAWINGS AND SPECIFICATIONS FOR TYPES OF CONSTRUCTION WHICH WILL CONTAIN EACH TYPE OF WALL REGISTER AND GRILLE. D. TYPES PROVIDE WALL REGISTERS AND GRILLES OF TYPE, CAPACITY, AND WITH ACCESSORIES AND FINISHES AS SCHEDULED. E. MANUFACTURERS: 1. TITUS PART 3.00 - EXECUTION 3.01 INSTALLATION A. GENERAL INSTALL OUTLETS AND INLETS IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS AND IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES TO INSURE THAT PRODUCTS SERVE INTENDED FUNCTIONS. REFER TO INSTALLATION DETAILS REFERENCED IN PARAGRAPH 2.03A ABOVE. B. COORDINATE WITH OTHER WORK, INCLUDING DUCTWORK AND DUCT ACCESSORIES, AS NECESSARY TO INTERFACE INSTALLATION OF OUTLETS AND INLETS WITH OTHER WORK. C. LOCATE CEILING AIR DIFFUSERS, REGISTERS, AND GRILLES, AS INDICATED ON GENERAL CONSTRUCTION "REFLECTED CEILING PLANS" AND "INTERIOR ELEVATIONS ". UNLESS OTHERWISE INDICATED, LOCATE UNITS IN CENTER OF ACOUSTICAL CEILING MODULES. END OF SECTION 15870 SECTION 15880 FILTERS PART 1.00 - GENERAL 1.01 GENERAL REQUIREMENTS A. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND OTHER CONDITIONS AND DIVISION 1 - GENERAL REQUIREMENTS SECTIONS, APPLY TO THE WORK SPECIFIED IN THIS SECTION. 1.02 COMPLIANCE A. NFPA COMPLIANCE: INSTALL AIR TREATMENT EQUIPMENT IN ACCORDANCE WITH NFPA 90A AND 900. B. UL COMPLIANCE: PROVIDE AIR FILTER UNITS WHICH HAVE BEEN LISTED AND LABELED BY UL. C. ASHRAE COMPLIANCE: TEST AIR FILTER UNITS IN ACCORDANCE WITH ARI 850. PART 2.00 - PRODUCTS 2.01 AIR FILTERS A. EXTENDED SURFACE FILTERS PROVIDE FACTORY - FABRICATED, DRY, EXTENDED SURFACE FILTERS; WHERE SHOWN, IN SIZES INDICATED. EQUIP WITH UL CLASS 1 FIBROUS MEDIA MATERIAL FORMED INTO 2" DEEP V- SHAPED PLEATS AND HELD BY SELF- SUPPORTING FRAMES. FARR 30/30 OR EQUAL. 2.02 FILTER FRAMES A. PROVIDE METAL FILTER FRAMES AS DETAILED ON DRAWINGS, PART 3.00 - EXECUTION 3.01 INSTALLATION A. INSTALL AIR FILTERS AND HOLDING DEVICES OF TYPES INDICATED, AND WHERE SHOWN; IN ACCORDANCE WITH AIR FILTER MANUFACTURER'S WRITTEN INSTRUCTIONS AND WITH RECOGNIZED INDUSTRY PRACTICES; TO ENSURE THAT FILTERS COMPLY WITH REQUIREMENTS AND SERVE INTENDED PURPOSES. COMPLY WITH APPLICABLE PORTIONS OF NFPA 70, 90A AND B, PERTAINING TO INSTALLATION OF AIR FILTERS. PROVIDE AS SCHEDULED ON THE DRAWINGS. B. INSTALL FILTERS IN PROPER POSITION TO PREVENT PASSAGE OF UNFILTERED AIR. C. PROVIDE CLEAN SET OF FILTERS FOR ALL PIECES OF EQUIPMENT: 1. IMMEDIATELY PRIOR TO AIR BALANCING. 2. WHEN FINAL PUNCHLIST IS DONE. 3. IN ADDITION, FURNISH ONE COMPLETE EXTRA SET OF FILTERS TO OWNER WHEN FINAL PUNCHLIST IS DONE. THREE SETS OF FILTERS ARE REQUIRED (TWO INSTALLED, ONE TURNED OVER TO OWNER). LOCATE EXTRA SET IN MECHANICAL ROOMS WHERE FILTERS ARE LOCATED. D. FILTERS SHALL BE EASILY CHANGED FROM FRAMES AND SHALL SLIDE FREELY ON TRACKS WITHOUT BINDING. MAINTAIN CLEAR ACCESS IN FRONT OF FILTER ACCESS DOOR TO FULL WIDTH OF THE FILTER. E. FILTER SECTIONS SHALL HAVE HINGED ACCESS DOORS WITH LATCHES. END OF SECTION 15880 SECTION 15980 BALANCING PART 1.00 - GENERAL 1.01 DESCRIPTION A. GENERAL REQUIREMENTS DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND OTHER CONDITIONS AND DIVISION 1 - - GENERAL REQUIREMENTS SECTIONS, APPLY TO THE WORK SPECIFIED IN THIS SECTION. 1.02 INDUSTRY STANDARDS A. ALL TESTING, ADJUSTING AND BALANCING OF ALL WORK SHALL BE PERFORMED BY AN INDEPENDENT CONTRACTOR WHO IS CURRENTLY LICENSED ASSOCIATED AIR BALANCING COUNCIL (MBC) OR NATIONAL ENVIRONMENTAL BALANCING BUREAU (NEBB) BALANCING CONTRACTOR. NO OTHER BALANCE REPORTS WILL BE REVIEWED OR ACCEPTED. ALL BALANCING WORK MUST BE COMPLETE AND DONE IN ACCORDANCE WITH THE MOST RECENT STANDARDS OF THEIR SOCIETY. PAYMENT OF ALL COSTS FOR TESTING AND BALANCING SHALL BE BY THE GENERAL CONTRACTOR. ALL BALANCING WORK SHALL BE PERFORMED WITH ACCORDANCE WITH LOCAL CODES AND THIS SECTION. 1.03 SUBMITTALS A. SUBMIT CERTIFIED TEST REPORTS SIGNED BY TEST AND BALANCE SUPERVISOR WHO PERFORMED TAB WORK, SUBMIT RECORD HVAC PLAN SHOWING ALL VOLUME DAMPER & REMOTE VOLUME DAMPER OPERATOR LOCATIONS & CONNECTION LINKAGE. B. THE BALANCE REPORT SHALL BE ON THE MBC NATIONAL STANDARD REPORT FORMS OR THE NEBB CERTIFIED REPORT FORMS AS PUBLISHED IN THEIR MOST CURRENT EDITIONS AND SHALL INCLUDE AS A MINIMUM THE FOLLOWING INFORMATION. 1. MBC OR NEBB CERTIFICATION NUMBER AND SIGNATURE OF BALANCING CONTRACTOR. 2. COPY OF A CERTIFICATE OF CONFORMANCE WITH NATIONAL STANDARDS FOR THIS PROJECT. 3. INSTRUMENTATION LIST WITH LAST CALIBRATION DATES. 4. MAKE AND MODEL NUMBERS OF ALL HVAC EQUIPMENT. 5. AIR CFM AND STATIC PRESSURE READINGS (DISCHARGE AND SUCTION) AS MEASURED BY PITOT TUBE DUCT TRAVERSE AT THE UNIT. 6. MOTOR NAMEPLATE DATA WITH ACTUAL FIELD VOLTAGE AND AMPERAGE READINGS FOR EACH LEG. 7. MOTOR AND FAN R.P.M.'S, SHEAVE SIZES AND BELT SIZES. 8. OUTSIDE, RETURN, MIXED AND SUPPLY AIR TEMPERATURES AND VOLUMES SHALL BE MEASURED AT FULL COOLING WITH MINIMUM OUTSIDE AIR. RETURN /RELIEF /SMOKE EVACUATION AIRFLOW SHALL BE BALANCED AND MEASUREMENTS RECORDED BY PITOT DUCT TRAVERSE AT FULL ECONOMIZER AND POWER EXHAUST. 9. MAKE AND MODEL NUMBERS OF ALL AIR DISTRIBUTION EQUIPMENT. 10. FINAL BALANCED AIR VOLUMES AT ALL OUTLETS (INCLUDING RETURNS WHERE DUCTED). 11. INDEXED PLAN WITH DIFFUSER AND RETURN LOCATIONS. ALSO INDICATE IF DIFFUSER IS 3 -WAY OR 2 -WAY. A. FIVE COPIES OF THE BALANCE REPORT SHALL BE SUBMITTED TO HOLD EVERYTHING PROJECT MANAGER FOR APPROVAL PROVIDE ONE COPY OF APPROVED REPORT TO LANDLORD UPON COMPLETION OF CONSTRUCTION FOR THE PREMISE AS A REQUIREMENT TO OPEN FOR BUSINESS. 1.04 JOB CONDITIONS A. WORK WILL NOT PROCEED WITH TESTING, ADJUSTING AND BALANCING WORK UNTIL WORK HAS BEEN COMPLETED AND IS OPERABLE. ENSURE THAT THERE IS NO LATENT RESIDUAL WORK STILL TO BE COMPLETED. INFORM ARCHITECT IN WRITING WHEN PROJECT IS READY FOR ADJUSTING AND BALANCING. B. REFER TO LANDLORD TENANT CRITERIA MANUAL FOR SYSTEM BALANCING REQUIRED AS PART OF TENANT WORK. PART 2.00 - PRODUCTS 2.01 GENERAL A. MECHANICAL SUB CONTRACTOR SHALL PROVIDE ALL MOTORS, SHEAVES, BELTS, LADDERS, ETC. AS REQUIRED FOR BALANCER TO ACCOMPLISH WORK. B. BALANCING SUB CONTRACTOR SHALL BE HIRED BY THE DIVISION 0 AT THE DIVISION 0 EXPENSE. BALANCING CONTRACTOR SHALL BE AN INDEPENDENT CONTRACTOR, SEPARATE COMPANY FROM THE MECHANICAL SUB CONTRACTOR. COORDINATE WITH LANDLORD, LANDLORD MAY REQUIRE SPECIFIC CONTRACTOR FOR BALANCING. PART 3.00 - EXECUTION 3.01 GENERAL A. EXAMINE INSTALLED WORK AND CONDITIONS UNDER WHICH TESTING IS TO BE DONE TO ENSURE THAT WORK HAS BEEN COMPLETED, CLEANED AND IS OPERABLE. DO NOT PROCEED WITH TAB WORK UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED IN MANNER ACCEPTABLE TO TESTER. B. TEST, ADJUST AND BALANCE AIR CONDITIONING SYSTEMS AND COMPONENTS, AS INDICATED, IN ACCORDANCE WITH PROCEDURES OUTLINED IN APPUCABLE STANDARDS. REFER TO LANDLORD TENANT CRITERIA MANUAL FOR SYSTEM BALANCING REQUIRED AS PART OF TENANT WORK. C. PREPARE REPORT OF TEST RESULTS IN FORMAT RECOMMENDED BY APPLICABLE STANDARDS. D. PATCH HOLES IN INSULATION, DUCTWORK AND HOUSING, WHICH HAVE BEEN CUT OR DRILLED IN MANNER RECOMMENDED BY THE ORIGINAL INSTALLER. E. MARK EQUIPMENT SETTINGS, INCLUDING DAMPER CONTROL POSITIONS, VALVE INDICATORS, FAN SPEED CONTROL LEVERS, AND SIMILAR CONTROLS AND DEVICES, TO SHOW FINAL SETTINGS AT COMPLETION OF BALANCE WORK. PROVIDE MARKINGS WITH PAINT OR OTHER SUITABLE PERMANENT IDENTIFICATION MATERIALS. F. INITIAL BALANCING SHALL INCLUDE BALANCING ALL AIR QUANTITIES TO WITHIN 10% OF THOSE LISTED ON THE DRAWINGS. G. BALANCER SHALL THEN CHECK ALL BUILDING TEMPERATURES AND READJUST AIR QUANTITIES TO EVEN OUT SPACE TEMPERATURES TO WITHIN 1 DEG. F WITHIN SPACES. H. TESTING, ADJUSTING AND BALANCING REPORT MUST BE COMPLETE AND TURNED OVER TO HOLD EVERYTHING PROJECT MANAGER 1 WEEK PRIOR TO STORE TURNOVER. I. THE HVAC SUB CONTRACTOR SHALL BE PRESENT FOR AIR BALANCE TO VERIFY ACCESSIBILITY TO ALL DEVICES, VERIFY ALL OPERATING SEQUENCES AND INSTALL NEW FILTERS IN ALL UNITS JUST PRIOR TO THE AIR BALANCE. THE COMPLETE AIR BALANCE SHALL TAKE PLACE WITH OUTSIDE AIR DAMPERS IN MINIMUM POSITION, EXCEPT AS NOTED OTHERWISE. HVAC SUB CONTRACTOR SHALL ALSO INSTALL A NEW SET OF FILTERS AFTER PROJECT IS COMPLETE. J. BALANCE AIR TO WITHIN PLUS /MINUS 10% OF THAT INDICATED ON THE DRAWINGS. ANY REQUIRED CHANGES IN SHEAVES, BELTS, PULLEYS OR THE ADDITION OF DAMPERS REQUIRED TO ACHIEVE SPECIFIED FLOW RATES SHALL BE PERFORMED BY THE HVAC SUB CONTRACTOR WITH NO ADDITIONAL COST TO HOLD EVERYTHING. K. THE BALANCING SUB CONTRACTOR SHALL PERFORM ALL APPLICABLE TESTING AND BALANCING FUNCTIONS REQUIRED FOR THE SYSTEM DESIGNED ON THESE DRAWINGS. ALL SYSTEMS UNABLE TO BE COMPLETELY BALANCED AT THE TIME OF ORIGINAL , BALANCE MUST BE BALANCED IN FUTURE AT NO ADDITIONAL EXPENSE TO HOLD EVERYTHING. THE BALANCING CON) �T�OR SHALL RECHECK ANY ITEMS THAT HOLD EVERYTHING DEEMS NECESSARY AT NO ADDITIONAL COST TO HOLD EVES. G C END OF SECTION 15980 tivx vtto SECTION 15990 CONTROLS OtI ' aF 1. IN ADDITION TO THERMOSTATS AND REMOTE ROOM TEMPERATURE SENSORS, 2. SET RTU'S & AHU'S THERMOSTATS FOR 73 D.F. COOLING AND 70 D.E. HEATING INITIALLY. END OF SECTION 15990 SECTION 15995 COMMISSIONING: C,1 �N"' PART 1.00 GENERAL ‘. � `"✓ 1. PROVIDE MECHANICAL SYSTEMS COMMISSIONING IN ACCORDANCE WITH LOCAL ENERGY CODE 6NHE°REQUIREMENTS OF THISSPECIFICATION. ALL CONTROL SEQUENCES SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE IN ACCORDANCE WITH THE 2. HVAC UNITS: OPERATE SYSTEM IN COOUNG MODE; RECORD OUTSIDE TEMPERATURE, MIXED AIR TEMPERATURE, SUPPLY AIR TEMPERATURE. WHERE ECONOMIZERS ARE SPECIFIED, DEMONSTRATE PROPER OPERATION OF CHANGEOVER FROM ECONOMIZER DAMPER OPERATION (FREE COOLING WITH OUTSIDE AIR) TO MECHANICAL COOLING (MINIMUM OUTSIDE AIR WITH COMPRESSOR COOLING). VERIFY THAT COOLING COIL SENSIBLE CAPACITY MATCHES THE TEMPERATURE DROP ON THE COOLING COIL VIA THE FORMULA COOLING CAPACITY (BTUH) = AIRFLOW (CFM) X (1.1) X DELTA T (MIXED AIR TEMP - SUPPLY AIR TEMP DEGREES F). OPERATE UNITS IN HEATING MODE: RECORD OUTSIDE AIR TEMPERATURE, MIXED AIR TEMPERATURE, SUPPLY AIR TEMPERATURE. VERIFY THAT HEATING COIL CAPACITY MATCHES THE TEMPERATURE RISE ON THE HEATING COIL VIA THE FORMULA HEATING CAPACITY (BTUH) = AIRFLOW (CFM) X (1.1) X DELTA T (MIXED AIR TEMP - SUPPLY AIR TEMP DEGREES F). VERIFY THE OPERATION OF ANY CONTROL VALVES WHERE PRESENT (CHILLED WATER OR HEATING WATER VALVES). VERIFY THAT EACH UNIT OPERATES WITH THE CORRECT THERMOSTAT/ SENSOR. SET THERMOSTATS FOR 70 F HEATING SETPOINT AND 72 F COOLING SETPOINT. UNIT FANS SHALL RUN CONTINUOUSLY DURING OCCUPIED MODE AND CYCLE ON /OFF DURING UNOCCUPIED MODE. SETUP AND VERIFY HOURS ON OPERATION (TIME SCHEDULE) FOR OCCUPIED /UNOCCUPIED MODE AND HOLIDAY /WEEKEND SCHEDULING. 3. VERIFY SMOKE DETECTOR SHUTDOWN OF ANY FAN UNITS SCHEDULED FOR SMOKE DETECTOR SHUTDOWN. 4. VERIFY PROPER OPERATION OF ANY OTHER HVAC EQUIPMENT THAT IS INTERLOCKED WITH OTHER EQUIPMENT. 5. PROVIDE CHECK OUT OF ALL PLUMBING SYSTEMS FOR PROPER OPERATION, INCLUDING HOT AND COLD WATER AT ALL FAUCETS, WATER HEATERS SET FOR PROPER TEMPERATURE, OPERATION OF ALL VALVES, GREASE TRAPS, GAS VALVES, MIXING VALVES. RECORD DATA ON ALL DEVICES CHECKED AND THE STATUS OF THEIR OPERATION. END OF SECTION 15995 w '0% RECEIVE APR n1ZO PERMIT CENTER 1 03 -29 -08 TENANT CHANGES DRAWN BY: KL COPYRIGHT 0 2008 CARD & BURGESS, II 03 -19 -08 ISSUE FOR PERMIT PROJECT NUMBER: SCALE: at &t Carter::Burgess Carter & Burgess, Inc. 4 Hutton Centre Drive, Suite 800 Santa Ana, California 92707 TEL: (714) 327 -1600 FAX: (714) 327 -1601 1EXPIRES 03/15/10 ISSUES /REVISIONS NO. DATE DESCRIPTION 16425 Southcenter Parkway TUKWILA, WA DESIGNED BY: KL CHECKED BY: MV APPROVED BY: MV 441805.011.039.0001 NONE MECHANICAL AND PLUMBING SPECIFICATIONS M -004 � 200 CFM (R SCALE: 1/4" = 1' -0" 8 "0 �Q -1 8 °0 2 T RG 2 12 "0 v-CHA\ICAL FLOOR PLA\ 24 "0 3/4 "COND 24 "0 1 CD 3 200 CFM 24 "0 (7) 350 CFM CD � 1 75 CFM -.. 100 CFM 4 100 CFM '1 0 RG 8 "0 5 6 "0 ( -66- 2 200 CFM / CD 1 75 CFIIA 12 "0 DROP 8 10"0 RTU -1 CD 3 200 CFM CD 3 200 CFM 20 "0 18"0 8 "0 G 1 2 "0`: 0 5 (TYP) 16 "0 CD 3 250 CFM 10 "0 1 0 "0 1 ( 350 CFM 16 "0 12 "0 14 "0 RG 5 12 CD 4 350 CFM 10 "0 1 0"0 CD 4 350 CFM' HVAC PLAN NOTES: CD INSTALL NEW EXHAUST FAN. REFER TO SCHEDULE ON SHEET M -600 & DETAIL 6/M -400 FOR MORE INFORMATION. 0 INSTALL NEW THERMOSTAT AS SHOWN AT 48" AFF. SEE DETAIL 1/M -400. GANG BOX AND CONDUIT BY ELECTRICAL. 0 INSTALL NEW ROOF TOP UNIT ON EXISTING 10 TON ROOF CURB. NOTIFY ENGINEER OF ANY DISCREPANCIES. E4 INSTALL NEW DIFFUSER. BORDER TO MATCH CEILING TYPE. REFER TO DIFFUSER SCHEDULE ON SHEET M -600. ® INSTALL NEW RETURN REGISTER. BORDER TO MATCH CEILING TYPE. REFER TO DIFFUSER SCHEDULE ON SHEET M -600. • RUN R -410 REFRIGERANT LINES FROM FAN COIL UNITS UNDER ROOF TO CONDENSING UNIT ON ROOF. SEE MECHANICAL SCHEDULE ON SHEET M -600 FOR LINE SIZES. :ii: ROUTE 3/4" CONDENSATE LINE ABOVE CEILING TO THE TAIL PIECE OF THE LAVATORY. SEE DETAIL 8/M -400. 0 FAN COIL UNIT LOCATED IN CEILING SPACE. • REFRIGERANT LINES UP THRU ROOF TO CONDENSING UNIT. 10 THERMOSTAT TO TURN ON EXHAUST FAN WHEN TEMPERATURE REACHES 90`F. 11 8 "0 OUTSIDE AIR DUCT UP THROUGH ROOF W/ ROOF CAP. PROVIDE INSECT SCREEN AT TERMINATION. 12 PROVIDE 1 -1/4" GAS PIPE CONNECTION TO UNIT. CONNECT TO EXISTING MAIN GAS PIPING ON ROOF. VERIFY THAT GAS SERVICE IS OPERATIONAL. NOTIFY ENGINEER OF ANY DISCREPANCIES. 13 UPON ACTIVATION OF THE SMOKE DETECTOR, THE UNIT SHALL AUTOMATICALLY SHUT DOWN AND AN ALARM SHALL BE SENT TO THE FIRE ALARM SYSTEM. COO s vst I� Pp 0 WO at &t WIRELESS — 16425 SOUTHCENTER PARKWAY TUKWILA, WA TOTAL FLOOR AREA —4368 S.F. OUTSIDE AIR PROVIDED — RTU —1: SALES FLOOR FC -1: MANAGER'S OFFICE OPEN OFFICE INVENTORY RESTROOMS OUTSIDE AIR SCHEDULE MINIMUM OA 0.20 CFM /S.F. 20 CFM /PERSON 50 CFM /TOILET CALCULATION 3712 S.F. x 0.20 CFM /S.F.= 743 20 CFM /PERSON x 3 PERSON= 60 50 CFM /TOILET x 2 TOILETS= 100 TOTAL: 750 CFM 75 CFM 100 CFM 925 CFM TABLE IS BASED FROM 2006 WASHINGTON STATE VENTILATION AND INDOOR AIR QUALITY CODE. RECEIVED APR 01 an PERMIT CENTE COPYRIGHT 0 CARTER & BURGESS. INC. at &t Carter:Burgess Carter & Burgess, Inc. 4 Hutton Centre Drive, Suite 800 Santa Ana, California 92707 TEL: (714) 327 -1600 FAX: (714) 327 -1601 1 EXPIRES 03/15/10 ISSUES /REVISIONS 1 03 -29 -08 TENANT CHANGES 03 -19 -08 ISSUE FOR PERMIT NO. DATE DESCRIPTION 16425 Southcenter Parkway TUKWILA, WA DESIGNED BY: KL CHECKED BY: MV DRAWN Y: KL PROJECT NUMBER: SCALE: NORTH APPROVED BY: MV 441805.011.039.0001 1 /4"=1'-0" MECHANICAL FLOOR PLAN 1 M -200 (N) 4 "SAN PLUMBING PLAN NOTES: 0 FIND THE SHORTEST DISTANCE TO ROUTE THE SANITARY PIPING TO THE NEAREST SANITARY MAIN. SLOPE AT A 1% MINIMUM. NOTIFY ENGINEER OF ANY DISCREPENCIES. 10 CONNECT NEW VENT TO EXISTING VENT IN CEILING SPACE. FIELD TO VERIFY EXACT LOCATION. 0 INSTALL NEW INSTANTANEOUS WATER HEATER (IWH -1) BELOW LAVATORY FOR HOT WATER CONNECTION. SEE DETAIL 5/M -400. PROVIDE NEW SHUT -OFF VALVE W /ACCESS. SAWCUT FLOOR AND PATCH AS REQUIRED. CONNECT NEW DOMESTIC WATER TO EXISTING DOMESTIC WATER IN CEILING SPACE. FIELD TO VERIFY EXACT LOCATION. APIA 0 1 2008 PERMIT CENTER COPYRIGHT 0 2008 CARTER & BURGESS, INC. 1 03 -29 -08 TENANT CHANGES at &t Carter:Burgess Carter & Burgess, Inc. 4 Hutton Centre Drive, Suite 800 Santa Ana, California 92707 TEL: (714) 327 -1600 FAX: (714) 327-1601 1 EXPIRES 03/15/10 ISSUES /REVISIONS - 03- 19-08 ISSUE FOR PERMIT NO. DATE DESCRIPTION 16425 Southcenter Parkway TU KW I LA, WA NORTH DESIGNED BY: KL CHECKED BY: KL DRAWN BY: KL PROJECT NUMBER: SCALE: APPROVED BY: MV 441805.011.039.0001 AS NOTED PLUMBING FLOOR PLANS M -201 COPYRIGHT 0 2006 CARTER & HURGE Carter:Burgess Carter & Burgess, Inc. 4 Hutton Centre Drive, Suite 800 Santa Ana, California 92707 TEL: (714) 327 -1600 FAX: (714) 327 -1601 1 EXPIRES 03/15/10 ISSUES /REVISIONS 1 03 -29 -08 TENANT CHANGES 03 -19 -08 ISSUE FOR PERMIT NO. DATE DRAWN BY: KL PROJECT NUMBER: SCALE: INC DESCRIPTION MECHANICAL AND PLUMBING DETAILS at &t 16425 Southcenter Parkway TU KWI LA, WA DESIGNED BY: KL CHECKED BY: MV APPROVED BY: MV 441805.011.039.0001 NONE M -400 ROOFCAP WITH INTEGRAL BIRDSCREEN (PROVIDED BY FAN MFR) ROOF SEE ARCH FOR FLASHING TWO SHEET METAL ROOF JOIST, SEE SELF TAPPING ARCHITECTURAL FOR SCREWS ROOF TYPE RA DUCT W/ 1" THICK LINER EXISTING ROOF CURB PACKAGED ROOF TOP UNIT SA DUCT W/ 1" THICK LINER ROOF q I -r SHEET METAL TWO SELF TAPPING SCREWS I TWIST STRAP - FLEX CONNECTION SOLID -LINED CEILING EXHAUST FAN CABINET SEE MECHANICAL EQUIP. SCHEDULE FOR SIZE. BRACING (TYP) _ L U ,--..Q / 1 ' �� ��� M � �/� %�� / ////ate, . -- � RECTANGULAR DUCTWORK ROUND DUCTWORK -\,/` `I � NOTES FLEXIBLE CONNECTION FOR FUTURE CONNECTIONS SPLITTER FITTING WWWWWWWWWWWWWWW - -_ IIIN A SEISMIC NOTES PROVIDE CAP UNIT AND DUCTWORK. EACH BRANCH DUCT SIZE THROUGH FITTING. i 1. ALL DUCT & SUPPORTS PER IMC. -V,-- 6" RIGID METAL REFER TO ARCHITECTURAL FOR CEILING DUCT BACKDRAFT DAMPER TYPE EXHAUST GRILLE (PROVIDED BY FAN MFR) 1. PROVIDE FLEXIBLE DUCT CONNECTION BETWEEN AIR CONDITIONING 2. WHERE SINGLE SUPPLY DUCTS SPLIT INTO TWO DUCTS MAINTAIN AND PROVIDE SINGLE TRANSITION ON UPSTREAM SIDE OF SPLITTER 3. PROVIDE CAP ON DUCT AFTER PENTRATION THRU ROOF. NOT USED SCALE: 12 DUCT PENETRATION DETAIL SCALE: 9 CEILING MOUNTED EXHAUST FAN DETAIL SCALE: 6 DUCT HANGER DETAIL SCALE: 3 N.T.S. N.T.S. NONE N.T.S. HOT OUTLET COLD INLET INSTANT FLOW 110V BY ELEC METAL FAN COIL P -TRAP REQUIRED W/ SEPARATE DRAIN TO EXISTING TRAP CONDENSATE --- ----LJ 1 SECURE TO STRUCTURE ABOVE 3" WIDE SHEET METAL STRAP 4" -0" OC 45' (2) 12 GA HANGER SCREWS PER TIGHTECTION. SEAL AIR DRAIN PAN _ _ • COPPER THREE WAY STOP VALVE —�� OVERFLOW PIPED SEPARATELY TO CONSPICUOUS LOCATION SUPPORT TO DECK ABOVE, TYP I CONNECT TO STRUCTURE ABOVE , SUSPENDED CEILING II GALV CLAMP CONDENSATE DRAIN FROM ABOVE 3/8" VIII I l& TUBING ROUND METAL HEATER - 1/2 -�� COLD ANGLE �- DUCT, TYP (1 -1/2" MAX SIZE) 1 ACOUSTICAL FLEX DUCT CEILING DIFFUSER /RETURN GRILLE 5'-O" MAXIMUM LENGTH SUSPENDED CEILING 4 J -BOX EXISTING FIXTURE I 1 ATTACH FLEX TO DUCT AND CEILING - - - - -- DIFFUSER USING MIN OF 3 SHEET METAL SCREWS. SEAL AIR w GASKET 1 .111 -� lar if* AIR GAP FITTING TIGHT ------. - EVIEVA tb \ CgD CM/WI-1°k AppROVED \ R 9 70 ■ , : "" ^' ---------- Of 11 "...t IF EXISTING TRAP EXISTING P- TRAP NOT USED SCALE: SCALE: INSTANTANEOUS WATER HEATER PIPING DETAIL SCALE CEILING DIFFUSER/RETURN GRILLE L CONNECTION DETAIL 2 NTS N.T.S. NONE N.T.S. BRASS CLEANOUT PLUG WALL CONSTRUCTION 48" 30" 24" MAIN SUPPLY DUCT (OR MAIN EXHAUST RETURN DUCT OR SUB -MAIN) _ SUB -MAIN) 1/4 W, 4" MIN W, 4" 1/4 MIN. PROVIDE VOLUME DAMPER TAPPED CLEANOUT TEE JR SMITH No. 4530, ZURN No. Z -1446 OR EQUAL PROVIDE VOLUME BRANCH DUCT— DAMPER — BRANCH DUCT - W THERMOSTAT, SUPPLY AIR DUCT EXHAUST / RETURN AIR DUCT VOLUME DAMPER AIR FLOW DUCT MAIN STAINLESS STEEL CLEANOUT COVER , oo SWITCH, OUTLET, TOP OF THERMOSTAT, CONTROL SWITCH, OUTLET, CONTROL ¢ xt _� _ .� ro � i1�l ll� erigirmin _ FINISHED FLOOR RECTANGULAR TO ROUND �' / SIDE DUCT TAKE -OFF 1 8 GAUGE VOLUME DAMPER WITH BRANCH .0.„ CONICAL TAP MAIN LOCKING QUADRANT SET (TYP FOR ALL SUPPLY / RETURN/ EXHAUST AIR BRANCH RUNOUTS) qECEIVED APR 01 MI PERM T CENTER NOT USED SCALE: 10 WALL CLEAN OUT DETAIL SCALE: 7 BRANCH TAKE -OFF DETAIL SCALE: 4 MOUNTING HEIGHT OVER OBSTRUCTION SCALE: 1 N.T.S. NONE N.T.S. N.T.S COPYRIGHT 0 2006 CARTER & HURGE Carter:Burgess Carter & Burgess, Inc. 4 Hutton Centre Drive, Suite 800 Santa Ana, California 92707 TEL: (714) 327 -1600 FAX: (714) 327 -1601 1 EXPIRES 03/15/10 ISSUES /REVISIONS 1 03 -29 -08 TENANT CHANGES 03 -19 -08 ISSUE FOR PERMIT NO. DATE DRAWN BY: KL PROJECT NUMBER: SCALE: INC DESCRIPTION MECHANICAL AND PLUMBING DETAILS at &t 16425 Southcenter Parkway TU KWI LA, WA DESIGNED BY: KL CHECKED BY: MV APPROVED BY: MV 441805.011.039.0001 NONE M -400 DIFFUSER SCHEDULE MARK NO. MANUFACTURER & MODEL NO. TYPE CFM RANGE MODULE SIZE (IN) NECK SIZE (IN) OPPOSE BLADE DAMPER MAX NC MAX PD MATERIAL MARK NO. CD TITUS PCS ADJUSTABLE BLADE PERFORATED FACE 0 -100 24X24 6 NO 25 0.1 STEEL FAN RPM 1 TOTAL CAPACITY (MBH) TITUS PCS ADJUSTABLE BLADE PERFORATED FACE 101 -200 24X24 8 NO 25 0.1 STEEL LAT (,�) ( CD 2 CD TITUS PCS ADJUSTABLE BLADE PERFORATED FACE 201 ®325 24X24 10 NO 25 0.1 STEEL TYPE 3 WB (') TITUS PCS ADJUSTABLE BLADE PERFORMED FACE 326 -400 24X24 12 NO 25 0.1 STEEL 750 CD 4 900 TITUS PCS ADJUSTABLE BLADE PERFORATED FACE 401 -550 24X24 14 NO 25 0.1 STEEL 120/180 ( CD 5 K7) PCS TITUS ADJUSTABLE BLADE PERFORATED FACE 551 -700 24X24 16 NO 25 0.1 STEEL 49.4 RG TITUS PAR PERFORATED FACE 0 -160 24X24 6 NO 25 0.1 STEEL UNIT SHALL COMPLETE PROVIDE SMOKE DETECTOR SMOKE DETECTOR FACTORY INSTALLED ( RG TITUS PAR PERFORATED FACE 161 -280 24X24 8 NO 25 0.1 STEEL 2 RG TITUS PAR PERFORATED FACE 281 -380 24X24 W NO 25 0.1 STEEL ( 3 (7) PAR PERFORATED FACE 381 -530 24X24 12 NO 25 0.1 STEEL RG TITUS PAR PERFORATED FACE 531 -640 24X24 14 NO 25 0.1 STEEL RG TITUS PAR PERFORATED FACE 641 -720 24X24 16 NO 25 0.1 STEEL 6 RG TITUS PAR PERFORATED FACE 721 -1500 24X24 22X22 NO 25 0.1 STEEL ( 7 NOTES: PROVIDE ROUND TO SQUARE ADAPTOR AS NEEDED. s 1' PACKAGED ROOF TOP UNIT SCHEDULE MARK NO. MANUFACTURER MODEL NO. LOCATION SERVICE NOMINAL CAPACITY (TONS) REFRIG TYPE AMBIENT DRY BULB ('F) MIN OSA CFM SUPPLY FAN COOLING HEATING COMPRESSOR CONDENSER FAN UNIT ELECTRICAL FILTERS UNIT DIMENSIONS L x W x H (IN) OPER WEIGHT (LBS) REMARKS CFM ESP (IN WG) FAN RPM BHP TOTAL CAPACITY (MBH) SENSIBLE CAPACITY (MBH) EER EAT LAT MAX FACE VELOCITY (FPM) INPUT CAPACITY (MBH) MAX. OUTPUT CAPACITY (MBH) AFUE (/) EAT (�F) LAT (,�) QUANTITY RLA LRA QUANTITY HP (EA) MOTOR RPM FLA (EA) MCA MOCP VOLTS /PH /HZ % EFF TYPE CO 'al" WB (') DB ('F) WB (T) 2" CARRIER 48TMD012 ROOF SALES 10 R -22 80 750 4000 0.8 900 2.30 119.3 113.5 10.1 80.0 64.0 60.6 56.0 500 120/180 144 80.0 41.0 73.9 MODEL # 95 NEO ANGLE DROP FRONT TERRAllO MOP RECEPTOR. 16.0 125.0 2 1/4 1100 1.4 49.4 60 208/3/60 30% PLEATED 88 X 58 X 50 1110 00001 RTU 1 NOTES::: UNIT SHALL COMPLETE PROVIDE SMOKE DETECTOR SMOKE DETECTOR FACTORY INSTALLED WITH INTERNAL VIBRATION ISOLATORS AND ECONOMIZER. 0 PROVIDE BURGLAR BARS AT SUPPLY AND RETURN AIR DUCTS. IN RETURN DUCT PER 2006 INTERNATIONAL MECHANICAL CODE. 0 PROVIDE MICRO METL #4682 -0202 POWER EXHAUST. INSTALL PER MANUFACTURER'S SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. RECOMMENDATIONS. PACKAGE UNIT WITH ONE POINT POWER CONNECTION. 0 0 PLU'/BING FIXTURE SCHEDULE ITEM DESCRIPTION MANUFACTURER W V CW HW QTY. W&V CW &MW TOTAL REMARKS AND SPECIFICATIONS F.U. TOTAL F.U. Ali INSTANTANEOUS WATER HEATER CHRONOMITE LABORATORIES, INC, - - 1/2" 1/2" 3 - - - - #M -20L, TANKLESS ELECTRIC WATER HEATER, FLOW ACTIVATED, STAINLESS STEEL HEATING COILS, ONE -4160 WATT, 208/1/60 VOLT, SINGLE PHASE, 20 AMP, 1/2" WATER CONNECTION, 6 "HX9 "WX2 -1/2 ", 80T -105T TEMPERATURE RANCE. ® W EF TWIN CITY T100 WATER CLOSET KOHLER 4" 2" 3/4" 1 2 4 8 2.5 5 #K -3465, 16 -1/2" HIGH ELONGATED RIM VITREOUS CHINA TWO -PIECE TOILET, COMPLETE WITH INGENIUM FLUSHING SYSTEM, BOWL: K -4278, TANK: K -4609, 2 -1/8" PASSAGEWAY, ULTRA -LOW CONSUMPTION TOILET, FLUSHES ON 1.6 GAL. OF WATER. ® Mr TWIN CITY T100 ELECTRICAL ROOM LAVATORY KOHLER 2" 1-1/2" 1/2" 1/2" 2 1 2 1 2 #K -2005, VITREOUS CHINA WALL -HUNG LAVATORY WITH HANGER, DRILLED FOR CONCEALED ARM CARRIER WITH FAUCET HOLES ON 4 CENTERS, FRONT OVERFLOW; FAUCET: #501- WFHDF, SINGLE HANDLE LAVATORY DECK FAUCET; METAL POP -UP DRAIN AND LIFT HOLE IN POLISHED CHROME. 1-1/4" TAILPIECE. PROVIDE 3/8" WALL SUPPLIES WITH STOP AND 1 -1/4" OFFSET DRAIN, METAL GRID STRAINER. (FURNISH AND INSTALL " BROCAR" #C500R -B TRAP WRAP FOR PF -2H) BROCAR TEL: (800) 827 -1207 INTERLOCK WITH LIGHT SWITCH. Q3 FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR, WIRED BY ELECTRICAL CONTRACTOR. PROVIDE BACKDRAFT DAMPER. 0 INTERLOCK WITH TEMPERATURE SENSOR. 0 ® MOP SINK FLORESTONE 3" 2" 3/4" - 1 4 4 2.5 2.5 MODEL # 95 NEO ANGLE DROP FRONT TERRAllO MOP RECEPTOR. w DRINKING FOUNTAIN HALSEY TAYLOR HAC8FSBL-Q ADA 2" 1-1/2" 1/2 " - 1 0.5 0.5 0.5 0.5 BI -LEVEL WATER COOLER: SURFACE MOUNT ELECTRIC WATER COOLER, 8.0 GPH AT CO DEC F TE L 1 2 0 /1/ 4.0REQUIRE4000TWATTS ENTIRE INSTALLATION SHALL DF 1 FIXTURE UNIT (F.U.) TOTALS 14.5 10.0 ALL FIXTURES TO BE SUPPLIED & INSTALLED BY PLUMBING CONTRACTOR. EXHAUST FAN SCHEDULE i MARK NO. MANUFACTURER &MODEL NO. SERVICE LOCATION TYPE CFM ESP (IN WG) QTY' DRIVE MOTOR OPER WEIGHT (LBS) REMARKS WATTS VOLTS /PH /HZ Ali TWIN CITY T100 RESTROOM CEILING BATHROOM ROOM 100 0.1 1 DIRECT 87 120/1/60 25 000 W 2 EF TWIN CITY T100 RESTROOM CEILING BATHROOM ROOM 100 0.1 1 DIRECT 87 120/1/60 25 r. ( 2 PROVIDE 3/4" CONDENSATE DRAIN CONNECTION TO UNIT. PROVIDE FACTORY INSTALLED 6.0KW SUPPLEMENTAL ELECTRIC HEATER MODEL# KFCEH0501N05. Lk TWIN CITY T100 ELECTRICAL ROOM CEILING BATHROOM ROOM 100 0.1 1 DIRECT 87 120/1/60 25 000 ® NOTES: INTERLOCK WITH LIGHT SWITCH. Q3 FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR, WIRED BY ELECTRICAL CONTRACTOR. PROVIDE BACKDRAFT DAMPER. 0 INTERLOCK WITH TEMPERATURE SENSOR. 0 PIPI \G MATERIAL LEGEND DOMESTIC WATER SS, VENT AND STORM PIPING UNDERGROUND PIPING UNDERGROUND PIPING 2" AND SMALLER -SOFT DRAWN COPPER, TYPE K, NO JOINTS BELOW FLOOR 2-1/2" AND LARGER -HARD DRAWN COPPER, TYPE K SERVICE WEIGHT CAST IRON PIPING, HUB AND SPIGOT TYPE ABOVE GROUND PIPING ABOVE GROUND PIPING 1/2" AND LARGER - HARD DRAWN COPPER, TYPE L 1 .-1 /2" AND SMALLER - HARD DWV COPPER DRAINAGE TUBE 2" AND LARGER - SERVICE WEIGHT CAST IRON PIPING HUB AND SPIGOT TYPE, HUBLESS SERVICE WEIGHT CAST IRON, PVC PIPE, SCHEDULE 40, SOCKET TYPE DWV PATTERN (WHERE PERMITTED BY LOCAL JURISDICTION). AIR- COOLED CONDENSING UNIT SCHEDULE MARK NO. MANUFACTURER & MODEL NO. LOCATION AMBIENT DRY BULB ('F) NOMINAL CAPACITY (TON) COMPRESSOR CONDENSER FAN UNIT ELECTRICAL REFRIG. LINE SIZE REFRIG. TYPE UNIT DIMENSIONS L x W x H (IN) OPER WEIGHT (LBS) REMARKS QUANTITY RLA ( LRA (EA) QUANTITY HP (EA) MOTOR RPM MCA (AMP) MOCP (AMP) VOLTS /PH /HZ GAS LINE LIQUID LINE CEILING CARRIER 25HCA324A ROOF 80 2 1 12.8 58.3 1 1/10 800 16.7 25 208/1/60 5/8 3/8 R -410 31X31X29 183 PROVIDE 3/4" CONDENSATE DRAIN CONNECTION TO UNIT. PROVIDE FACTORY INSTALLED 6.0KW SUPPLEMENTAL ELECTRIC HEATER MODEL# KFCEH0501N05. AL w NOTES: HEAT PUMP UNIT. FAN COIL UNIT SCHEDULE MARK NO. MANUFACTURER & MODEL N0. LOCATION MIN OSA CFM ESP (IN WC) MOTOR HP COOLING COIL ELECTRICAL UNIT UNIT DIMENSIONS L x W x H (IN) OPER WEIGHT (LBS) REMARKS TOTAL CAPACITY (MBH) SENSIBLE CAPACITY (MBH) EAT LAT VOLTS /PH /HZ MCA (AMP) MOCP (AMP) DB ('F) WB ('F) DB ('F) WB 'F) 2 CARRIER FX4CNF024 CEILING 175 0.3 1/3 24 24 80 64 60 55 208/1/60 26.1 30 48X18X22 117 00 AIL NOTES: c PROVIDE 3/4" CONDENSATE DRAIN CONNECTION TO UNIT. PROVIDE FACTORY INSTALLED 6.0KW SUPPLEMENTAL ELECTRIC HEATER MODEL# KFCEH0501N05. PIPE SIZE GPM FT /SEC MAX FU 1/2" 2.3 2.9 3 3/4" 5.5 3.8 7 1" 12 4.5 16 1-1/4" 20 5.2 30 1-1/2" 30 6.0 54 2 70 7.5 225 NOTES: MAX VELOCITY IN WATER PIPE 8 FT /SEC. FOR COLD WATER. MAX VELOCITY IN WATER PIPE 5 FT /SEC. FOR HOT WATER. PLUMBING CONTRACTOR TO VERIFY AND COORDINATE EXACT STREET PRESSURE AND NOTIFY ENGINEER OF ANY DISCREPANCIES. PLUMBING CONTRACTOR TO PROVIDE A PRESSURE REDUCING VALVE (PRV) ON CUSTOMER SIDE OF WATER METER IF THE STREET PRESSURE EXCEEDS 80 PSI, PRV TO BE SET AT 60 PSI. THE FOLLOWING CHART IS USED TO SIZE THE TYPE L COPPER, COLD WATER PIPING IN ACCORDANCE WITH CPC APPENDIX A AT 4.0 P.S.I. / 100 FT. LOSS T6--- 9,73 ECE VE APR ` 01 ZOO pERMrr CENTER DRAWN BY: KL COPYRIGHT 0 2000 CARTER & BURGESS. INC. PROJECT NUMBER: SCALE: at &t Carter:Burgess Carter & Burgess, Inc. 4 Hutton Centre Drive, Suite 800 Santa Ana, California 92707 TEL: (714) 327- 1600 FAX: (714) 327-1601 1 EXPIRES 03/15/10 ISSUES /REVISIONS 1 03 -2908 TENANT CHANGES 03 -19 -08 ISSUE FOR PERMIT NO. DATE DESCRIPTION 16425 Southcenter Parkway TUKWILA, WA DESIGNED BY: KL CHECKED BY: MV APPROVED BY: MV 441805.011.039.0001 NONE MECHANICAL AND PLUMBING SCHEDULES M -600