Loading...
HomeMy WebLinkAboutPermit PG08-103 - ADHAMON RESIDENCEADHAMON RESIDENCE 16421 51 AV S PGO8-1 03 Parcel No.: 5379802745 Address: Suite No: Citylf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16421 51 AV S TUKW PLUMBING /GAS PIPING PERMIT Permit Number: Issue Date: Permit Expires On: PG08 -103 04/04/2008 10/01/2008 Tenant: Name: ADHAMON RESIDENCE Address: 16421 51 AVE S , TUKWILA WA Owner: Name: ADHANOM TEKLE Address: 16421 51ST AVE S , SEATTLE WA Contact Person: Name: CAROL RANDALL Address: 12601 132ND AVE NE , IURKLAND WA Contractor: Name: FAST WATER HEAT COMPANY Address: 12601 132ND AVE NE , KIRKLAND WA Contractor License No: FASTVWVH948BC Phone: Phone: 800 - 454 -8955 X133 Phone: (425)814 -3124 Expiration Date: 01/03/2010 DESCRIPTION OF WORK: REMOVE AND REPLACE GAS WATER HEATER Value of Plumbing /Gas Piping: $500.00 Fees Collected: Uniform Plumbing Code Edition: 2006 $92.00 International Fuel Gas Code Edition: Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet FIXTURE TYPE AND QUANTITY 2006 Plumbing (cont.) 0 Building sewer and each trailer park sewer 0 0 Rain water system - per drain (inside bldg) 0 0 Water heater and/or vent 1 0 Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 0 grease interceptors 0 0 Repair or alteration of water piping and/or water 0 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 0 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 0 0 Medical gas piping (6 +) inlets /outlets 0 0 Gas Piping 0 Gas piping outlets (0 -5) 0 0 Gas piping outlets (6 +) 0 * *continued on next page ** doc: UPC -10/06 PG08 -103 Printed: 04 -04 -2008 City ofTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: PG08 -103 Issue Date: 04/04/2008 Permit Expires On: 10/01/2008 Permit Center Authorized Signature: Date: 1-1'1-l_00 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of • •r •r I . . thorized to sign and obtain this plumbing /gas piping permit. /f fi Date: Signature: Print Name: 7C Rit This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -10/06 PG08 -103 Printed: 04 -04 -2008 Parcel No.: 5379802745 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16421 51 AV S TUKW ADHAMON RESIDENCE PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: PG08 -103 ISSUED 04/04/2008 04/04/2008 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. * *continued on next page ** doc: Cond -10/06 PG08 -103 Printed: 04 -04 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance o work. Signature: Print Name: 01C-k--(-1/ ( Date: doc: Cond -10/06 PG08 -103 Printed: 04 -04 -2008 CITY OF TUKWILA Community Development eartment Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us • Plambing/Gas P ItNo�a Off' �B ij ra cg are ::on PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print" Site Address: 164251 AVE S j� ''() ∎ / New Tenant: Tenant Name: ,I`f �a �i�"- ftb' dam'" 398123 King Co Assessor's Tax No.: 5379802745 Suite Number: Property Owners Name: ADHAMON, TEKLE Mailing Address: 16421 51 AVE S Floor: [] .... Yes [j ..No City State Zip Name: ADHAMON, TEKLE Mailing Address: E -Mail Address: I PLUNGING: I GAS PIPING: CONTRACTOR�INFORMA; Company Name: FAST WATER HEATER COMPANY Mailing Address: 12601 132ND AVE NE Contact Person: Carol Randall E -Mail Address: carolr @fastwaterheater.com Contractor Registration Number: FASTWWH948BC Day Telephone: (206)431 -5662 City Fax Number: State Zip KIRKLAND WA City State Day Telephone: 800 -454 -8955 x 133 Fax Number: 425 814 -9516 Expiration Date: 1/4/2010 98034 Zip Company Name: Mailing Address: Contact Person: E -Mail Address: Company Name: Mailing Address: City Day Telephone: Fax Number: State Zip All plans muStbe wet :s..tamped byiEngineer:of Record • Contact Person: E -Mail Address: _ City Day Telephone: Fax Number: State Zip Page 1 of 2 Valuation of Project (contractor's bid price :: $ `x-00 � - • Scope of Work (please provide detailed information): Remove /Replace Gas Water Heater Building Use (per Intl Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: ypo,....;':.:. -Qty:;; ;Fiatnre' 'Pe ;:;, ' :. :,';: ':';Qty: ,.:FGtture'T a :.,, :::; - YP . ; . ;:., Qty •;Fixture: Fixture Type::. Qty . Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder; commercial Receptor, indirect waste Clothes washer, domestic Floor drain Sinks Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent 1 Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and /or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas :Value of Construction — In all cases, a:value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Carol M W Randall Mailing Address: 12601 132ND AVE NE Date: 3/25/08 Day Telephone: 800 -454 -8955 x 133 KIRKLAND WA 98034 City State Zip IDate Application Accepted: Date Application Expires: Staff Initials: i Q :Uppllcalion.SFonns•Apptlentons On LineU•2006 - Plumbing -Gns Piping Penni Appnulion.doc awned: 4-2006 bh Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 5379802745 Permit Number: PG08 -103 Address: 16421 51 AV S TUKW Status: PENDING Suite No: Applied Date: 04/04/2008 Applicant: ADHAMON RESIDENCE Issue Date: Receipt No.: R08 -01028 Payment Amount: $92.00 Initials: WER Payment Date: 04/04/2008 11:03 AM User ID: 1655 Balance: $0.00 Payee: FAST WATER HEATER TRANSACTION LIST: Type Method Descriptio Amount Payment Check 4845 92.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLUMBING - RES 000.322.103.00.0 92.00 Total: $92.00 790 3 :: /O.. 71 TOTAL 92.00 doc: Receiot -06 Printed: 04 -04 -2008 INSPECTION NO. INSPECTION RECORD Retain a copy with permit P6va- - I03' PERMIT NO. CITY OF TUKWILA BUILDING DIVISION g. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)43 1 -3670 \A Proj ct: AiIi., rk -ia.� , ?rs,1A� Type of Inspection: rl (',AF 1 /L�At � A Address: „ii j(4 i 1 Sf 11v S Date Called: Specia Instructions: `k. - •.,+ " Date Wanted: a.m. S— Z 3' U p.m. Requester: Phone No. /b(0- 43I_Voc0Zf Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: pefibt:T— &oat -.1)(0.;(-4-‘...--,_ Inspect t4 El $58.00 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: Look Up a Contractor, Electrician or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. License Information License FASTWWH948BC Licensee Name FAST WATER HEATER COMPANY Licensee Type CONSTRUCTION CONTRACTOR UBI 602564544 Ind. Ins. Account Id 5380601 Business Type LIMITED LIABILITY COMPANY Address 1 12601 132ND AVE NE Address 2 City KIRKLAND County KING State WA Zip 98034 Phone 4258143124 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 1/3/2006 Expiration Date 1/4/2010 Suspend Date Separation Date Parent Company FWH ACQUISITION COMPANY LLC Previous License FASTWHC052DF Next License Associated License Business Owner Information Name Role Effective Date Expiration Date JORDAN, JEFF PARTNER/MEMBER 01/03/2006 HANLEYBROWN, JASON PARTNER /MEMBER 01/03/2006 • Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date DEVELOPERS Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= FASTWWH948BC 04/04/2008