HomeMy WebLinkAboutPermit PG08-129 - WESTFIELD SOUTHCENTER MALL - BOUTIQUE VIVIDBOUTIQUE VIVID
2887 SOUTHCENTER MALL
PGO8-129
Parcel No.: 6364200010
Address:
Suite No:
City if Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tulcwila.wa.us
PLUMBING /GAS PIPING PERMIT
2887 SOUTHCENTER MALL TUICW
Permit Number:
Issue Date:
Permit Expires On:
PG08 -129
06/11/2008
12/29/2008
Tenant:
Name: BOUTIQUE VIVID
Address: 2887 SOUTHCENTER MALL , TUKWILA WA
Owner:
Name: WESTFIELD PROPERTY TAX DEPT
Address: PO BOX 130940 , CARLSBAD CA
Contact Person:
Name: KEITH SMITH
Address: 1725 WESTLAKE AVE N SUITE 210 , SEATTLE WA
Contractor:
Name: AMERICAN MECHANICAL CORP
Address: PO BOX 1136 , MONROE WA
Contractor License No: AMERIMC071BH
Phone:
Phone: 206 - 713 -4076
Phone: (206)467 -6407
Expiration Date: 01/08/2009
DESCRIPTION OF WORK:
NEW RESTROOM FOR FUTURE TENANT
Value of Plumbing /Gas Piping:
Fees Collected:
$25,000.00
$241.00
Uniform Plumbing Code Edition: 2006
International Fuel Gas Code Edition: 2006
FIXTURE TYPE AND QUANTITY
Plumbing
Bathtub or combination bath/shower 0
Bidet 0
Clothes washer, domestic 0
Dental unit, cuspidor 0
Dishwasher, domestic, with independent drain 0
Drinking fountain or water cooler (per head) 0
Food -waste grinder, commercial 0
Floor drain 1
Shower, single head trap 0
Lavatory 1
Wash fountain
Receptor, indirect waste 0
Sinks 0
Urinals 0
Water Closet 1
0
Plumbing (cont.)
Building sewer and each trailer park sewer 0
Rain water system - per drain (inside bldg) 0
Water heater and /or vent 1
Industrial waste treatment interceptor, including
its trap and vent, except for kitchen type
grease interceptors 0
Repair or alteration of water piping and/or water
treatment equipment 0
Repair or alteration of drainage or vent piping 0
Medical gas piping system serving (1 -5)
inlets /outlets for a specific gas 1
Medical gas piping (6 +) inlets /outlets 1
Gas Piping
Gas piping outlets (0 -5) 0
Gas piping outlets (6 +) 0
* *continued on next page **
doc: UPC -10/06
PG08 -129 Printed: 07 -21 -2008
City ofTukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206- 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Permit Number: PG08 -129
Issue Date: 06/11/2008
Permit Expires On: 12/29/2008
Permit Center Authorized Signature:
Lu;,-,UL
Date: / d` I tv 8
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to •: ve authority to violate or cancel the provisions of any other state or local laws regulating
construction or
Signature.
Print Name:
ormance o
uthorized to sign and obtain this plumbing /gas piping permit.
Date:
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: UPC -10/06
PG08 -129 Printed: 07 -21 -2008
Parcel No.: 6364200010
Address:
Suite No:
Cityef Tukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
PLUMBING /GAS PIPING PERMIT
2887 SOUTHCENTER MALL TUKW
Permit Number:
Issue Date:
Permit Expires On:
PG08 -129
06/11/2008
12/08/2008
Tenant:
Name:
Address:
Owner:
Name:
Address:
WESTFIELD VANILLA BOX
2887 SOUTHCENTER MALL , TUKWWILA WA
WESTFIELD PROPERTY TAX DEPT
PO BOX 130940 , CARLSBAD CA
Contact Person:
Name: KEITH SMITH
Address: 1725 WESTLAKE AVE N SUITE 210 , SEATTLE WA
Contractor:
Name: AMERICAN MECHANICAL CORP
Address: PO BOX 1136 , MONROE WA
Contractor License No: AMERIMC071BH
Phone:
Phone: 206 - 713 -4076
Phone: (206)467 -6407
Expiration Date: 01/08/2009
DESCRIPTION OF WORK:
NEW RESTROOM FOR FUTURE TENANT
Value of Plumbing /Gas Piping:
Fees Collected:
$25,000.00
$181.00
Plumbing
Bathtub or combination bath/shower
Bidet
Clothes washer, domestic
Dental unit, cuspidor
Dishwasher, domestic, with independent drain
Drinking fountain or water cooler (per head)
Food -waste grinder, commercial
Floor drain
Shower, single head trap
Lavatory
Wash fountain
Receptor, indirect waste
Sinks
Urinals
Water Closet
Uniform Plumbing Code Edition: 2006
International Fuel Gas Code Edition: 2006
FIXTURE TYPE AND QUANTITY
Plumbing (cont.)
0 Building sewer and each trailer park sewer 0
0 Rain water system - per drain (inside bldg) 0
0 Water heater and/or vent 1
0 Industrial waste treatment interceptor, including
0 its trap and vent, except for kitchen type
0 grease interceptors 0
0 Repair or alteration of water piping and/or water
1 treatment equipment 0
0 Repair or alteration of drainage or vent piping 0
1 Medical gas piping system serving (1 -5)
0 inlets /outlets for a specific gas 1
0 Medical gas piping (6 +) inlets /outlets 1
0 Gas Piping
0 Gas piping outlets (0 -5) 0
1 Gas piping outlets (6 +) 0
* *continued on next page **
doc: UPC -10/06
PG08 -129 Printed: 06 -11 -2008
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Permit Number: PG08 -129
Issue Date: 06/11/2008
Permit Expires On: 12/08/2008
Permit Center Authorized Signature:
I hereby certify that I have read and e
governing this work will be complied
a
Date: c(l41 ")
ed this permit and know the same to be true and correct. All provisions of law and ordinances
whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or t) pe�form rice of work. I am authorized to sign and obtain this plumbing /gas piping permit.
Signature: Date: 6 '//-Q
Print Name: 6 a (,/ 1-\
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: UPC -10/06
PG08 -129 Printed: 06 -11 -2008
Parcel No.: 6364200010
Address:
Suite No:
Tenant:
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
PERMIT CONDITIONS
2887 SOUTHCENTER MALL TUKW
BOUTIQUE VIVID
Permit Number:
Status:
Applied Date:
Issue Date:
PG08 -129
ISSUED
04/24/2008
06/11/2008
1: ** *PLUMBING AND GAS PIPING * **
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila
Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing
inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas
Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code.
Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to
make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless,
adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the
conditioned space shall be insulated to minimum R -3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be
protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing
piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in
accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to
twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill,
frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the
jurisdiction.
* *continued on next page **
doc: Cond -10/06
PG08 -129 Printed: 07 -21 -2008
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work
construction or the performance of work.
Signature:
Print Name:
exri
/1,0-77
Date: 7/y
ordinances governing
or local laws regulating
doc: Cond -10/06 PGO8 -129
Printed: 07 -21 -2008
Parcel No.: 6364200010
Address:
Suite No:
Tenant:
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tukwila.wa.us
PERMIT CONDITIONS
2887 SOUTHCENTER MALL TUKW
WESTFIELD VANILLA BOX
Permit Number:
Status:
Applied Date:
Issue Date:
PG08 -129
ISSUED
04/24/2008
06/11/2008
1: ** *PLUMBING AND GAS PIPING * **
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila
Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing
inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas
Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code.
Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to
make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless,
adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the
conditioned space shall be insulated to minimum R -3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be
protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing
piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in
accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to
twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill,
frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the
jurisdiction.
* *continued on next page **
doc: Cond -10/06
PG08 -129 Printed: 06 -11 -2008
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating
construction or the performance of work.
Signature:
Print Name:
Aavi-d
J
Date: 6 / / ^Q a
doc: Cond -10/06
PG08 -129 Printed: 06-11 -2008
t;lsiR CONTRAG)TOR ORIVI
4,,W :''f+`' +st w =w• -:&Fr+ ^'�^'"°x»✓" tine - .T -,d
v(Contractorl[nfoinamon,for Mechanica,(pg 4) forPlumbing and Gas "Piping fpg 5))
l
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http: //www. ci. tukwila. wa. us
Site Address: NIP
Tenant Name:
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
Property Owners Name:
Mailing Address:
we
AIM
off / Kin Co Assessor's Tax No.: 636412D" D / �d� JJ
�� Suite Number: Floor: di�le
411
Id fla �x
New Tenant: Xi Yes ❑ ..No
.S I. � t. r7 Il 1#PNF: :'
City
tate
tp
�NT�CwT PERSON;
Name:
yourpertmit•is�ready; o,be>tssued
' //'' Day Telephone: -W�%
Mailing Address: l 7 5 ff€$ Q et 1 L At, Sc G�it 7j (O d9
,. ' City f state
E -Mail Address:
Ks m. G s G t l i CQvei Fax Number: �'Q �Q 4-414- d lef/
Company Name: •
Mailing Address:
City
Contact Person:
E -Mail Address:
Contractor Registration Number:
State
Zip
Day Telephone:
Fax Number:
Expiration Date:
ELFEECT OF CURD t p s
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
Gfh eel G1G
say G ry Liviro w,t T
Archi ect of - ecord}
740 ra.
State !Zip
ri l rl / /
City
Day Telephone:
Fax Number:
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Q:Wpplieatiens\Fonns- Applications On Line n -2006 - Permit Apptication.doc
Revised 9-2006
State Zip
bb
Page 1 of 6
PLUMBING AN IP
D GAS`PING PERMIT INFORMATION-.. 206 431- 3670
PLUMBING AND GAS PIPING CONTRACTOR INFORMATION
Company Name:
Mailing Address: -
City State Zip
Contact Person: - Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
Valuation of Plumbing work (contractor's bid price): $ i' OOU
Valuation of Gas Piping work (contractor's bid price): $
Scope of Work (please provide detailed information): nati /G f
Building Use (per Int'l Building Code):
Occupancy (per Int'l Building Code):
Utility Purveyor: Water: 7vvAwl
Sewer:
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
��P �"�e.�n.t' -'3: RTi� ,,k
F�afure.IType... -.x�A.
=.QrS�:•
Y'�Y'r C'. :ati.Yin•� '�:•.t. y�
:4Fiature Typed- .rc �i �E..::
.�.
Qty<��
_ iMi'S
�Fiztiiire- 'Type• -� : F ,
yt .. ;�.- '°iFfs':'
, RtY -,.�
� w� ac4'.�:: u'"'a..4 ,v�t.CSn
;�Fizfui'e Type , <7.;�•r�; �� -..:4
1'
;Qty;
Bathtub or combination
bath/shower
Drinking fountain or water
cooler (per head)
Wash fountain
Gas piping outlets
Bidet
Food -waste grinder,
commercial
Receptor, indirect
waste
Clothes washer, domestic
Floor drain
/
Sinks
Dental unit, cuspidor
Shower, single head trap
Urinals
Dishwasher, domestic,
with independent drain
Lavatory
(
Water Closet
/
/
Building sewer or trailer
park sewer
Rain water system — per
drain (inside building)
Water heater and/or
vent
(
Additional medical gas
inlets/outlets — six or more
Industrial waste
pretreatment interceptor,
including its trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of water
piping and/or water treating
equipment
Repair or alteration
of drainage or vent
piping
I
Medical gas piping system
serving one to five
inlets/outlets for specific gas
Q: ApplicaionsTo ms- Applications On Line 3 -2006 -Permit Applicat on.doc
Revised: 9 -2006
bh
Page 5 of 6
1PERIVIIT APPLICATION NOTES ;L Applicable to all pei-mlts iri thts applicatiiin •
.i•� Y. ?',g•, '4 1+�p Y'. r ^.'.: /.: ^L `-ci iii �•' S. ?:.h. •a �V a . +..1..,?. +. x, ,.� .4 ,:+..r _� et {.A'..
2ti u3:.� i _ -� }°Y° ..�:' ';: •- +�:;;'#.t�: �'.: 1,. ,',>,::�': ...."'�?r•a +. . >.,`?'�: ij� n. x �,.r�;.;�': 5; ;� ^r. 1: +t.�:s° : a`�i•.• �r 7
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNE
Signature:
RIZED AGENT:
Print Name:
Mailing Address:
Day T ephone:
cuc Q %to
Date: 4 (64—k
State
Date Application Accepted: , ` . o
1—� J
Date Application Expires: ,1 - ��
U'
jU(
Staff Initials: I
Q: Applieations\Fonns- Applications On rS1e3-2006. Permit Applieation.doc
Revised 9 -2006
bh
Page 6 of 6
Parcel No.: 6364200010
Address:
Suite No:
Applicant: BOUTIQUE VIVID
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
2887 SOUTHCENTER MALL TUKW
RECEIPT
Permit Number:
Status:
Applied Date:
Issue Date:
PG08 -129
ISSUED
04/24/2008
06/11/2008
Receipt No.: R08 -02673
Initials: WER
User ID: 1655
Payment Amount:
Payment Date:
Balance:
$60.00
07/21/2008 02:46 PM
$0.00
Payee:
AMC
TRANSACTION LIST:
Type Method
Descriptio Amount
Payment Check
ACCOUNT ITEM LIST:
Description
19535 60.00
Account Code
Current Pmts
PLUMBING - NONRES 000.322.103.00.0
60.00
Total: $60.00
dor.: Raraint -0R
PrintPrl: 07- 21 -200R
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http:/lwww.ci.tukwila.wa.us
SET RECEIPT
RECEIPT NO: R08 -02070
Initials: JEM
User ID: 1165
Payee: AMC
Payment Date: 06/11/2008
Total Payment: 3,404.00
SET ID: 0611
SET TRANSACTIONS:
Set Member Amount
PG08 -083 164.00
PG08 -085 164.00
PG08 -086 188.00
PG08 -104 164.00
PGO8 -105 164.00
PG08 -128 512.00
iP,G08,74Z2'V 512.00
PG08 -130 512.00
PG08 -131 512.00
PGO8 -132 512.00
TOTAL: 3,404.00
SET NAME: WESTFIELD PLUMBING
TRANSACTION LIST:
Type Method Description Amount
Payment Check 19416 3,404.00
TOTAL: 3,404.00
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
PLAN CHECK - NONRES
PLUMBING - NONRES
000/345.830 1,800.00
000.322.103.00.0 1,604.00
TOTAL: 3,404.00
3538 06 /11 9711 TOTAL 3404.00
•
City of Tukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 6364200010 Permit Number: PG08 -129
Address: 2887 SOUTHCENTER MALL TUKW Status: PENDING
Suite No: Applied Date: 04/24/2008
Applicant: WESTFIELD VANILLA BOX Issue Date:
Receipt No.: R08 -01307
Initials: WER
User ID: 1655
Payment Amount: $29.00
Payment Date: 04/24/2008 11:05 AM
Balance: $152.00
Payee: WESTFIELD
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 06012498 29.00
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
PLAN CHECK - NONRES
000/345.830 29.00
Total: $29.00
1610 04/24 9711 TOTAL 1160.45
doc: Receipt -06 Printed: 04 -24 -2008
INSPECTION RECORD
Retain a copy with permit
et)-12
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION k
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Probe t:
Type of Inspection:
cp....s„87 %77�/
Instructions:
/
Date Called:
Special
Date Wanted: ed�^^��
7"' 22— _ cpc� d.s.,T1N
Requester:
Phone .204,-336-9'C /7
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
F/ .11 d /C° 4
/34..eknU c.J p /tie n-42_ ' kid
ieg ,
by G'l%'> I Jc(
Inspector:
Date: 7/7, ziG
❑ $60. i y EINSPECTION FEE REQUIRED. Prior to inspection, fee must be
pai . - 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36
PERMIT NO.
Project: ,r /e. 4/
'�/jv/ P. UI�
Type of Inspections
�/Ja_�C,q�
Address: ^ �-/
/��
Date Called:
Special Instructions:
Aar : LAG i1 Oral 1 11
Date Wanted:
a?
a.r
P.m.
Requester:
&c:..- reasP PA-0
Phone No:
3..35' 99/7
Approved per applicable codes.
7
ElCorrections required prior to approval. /
COMMENTS: vo/ ^
I
Zw Dif.r.)■0 1)<.
(
Aar : LAG i1 Oral 1 11
4
&c:..- reasP PA-0
G
PR-O% Atx)-7 I 11a4,A4-1)
Inspector:, E / ! 7 A
Date; pi %al®5
❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
ACTIVITY NUMBER: PG08 -129
PROJECT NAME: BOUTIQUE VIVID
SITE ADDRESS: 2887 SOUTHCENTER MALL
DATE: 7 -14 -08
Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter # X Revision # 1 After Permit Issued
■
• o
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
DEPARTMENTS:
ZaIV 1-11'°
ng uivision X
Public Works
W'- / (1
Fire Prevention
Structural
n
o
Planning Division
Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
-i
Incomplete n
DUE DATE: 7-17-08
Not Applicable
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROUTING:
Please Route
1--/
Structural Review Required
No further Review Required
n
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved u Approved with Conditions
Notation:
REVIEWER'S INITIALS:
DUE DATE: 8-14 -08
Not Approved (attach comments)
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing sl ip.doc
2 -28 -02
• •
PERMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: PG08 -129 DATE: 04 -24 -08
PROJECT NAME: WESTFIELD VANILLA BOX
SITE ADDRESS: 2887 SOUTHCENTER MALL
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # After Permit Issued
DEPARTMENTS:
Bind/�
ing" Division
Fire Prevention 1 I Planning Division
Publi Works Ik4.1990 Structural ❑ Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 04 -29 -08
Complete
Comments:
Incomplete
Not Applicable
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route ❑ Structural Review Required ❑ No further Review Required
REVIEWER'S INITIALS:
DATE:
APPROVALS OR CORRECTIONS:
Approved ❑ Approved with Conditions
Notation:
REVIEWER'S INITIALS:
DUE DATE: 05 -27 -08
Not Approved (attach comments) ❑
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing stlp.doc
2 -28-02
PROJECT NAME: Pj l vSV 1 J\ Al
SITE ADDRESS: vim-- (-,e, MMI
•
PERMIT NO: ?(0)
ORIGINAL ISSUE DATE: ae(,lkh9
REVISION LOG
REVISION
NO.
DATE
RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
1
DI"
I4InA _
1 �i1-OK
Vt4f.
Summary of Revision: a ytjK -m --CI
Received by: � 4
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
•
Summary of Revision:
Received by:
(please print)
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
•
Summary of Revision:
Received by:
(please print)
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
•
Summary of Revision:
Received by:
(please print)
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
•
Summary of Revision:
Received by:
(please print)
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
Summary of Revision:
Received by:
(please print)
•
City of Tukwila
Steven M Mullet, Mayor
Department of Community Development
6300 Southcenter Boulevard, Suite 4100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Steve Lancaster, Director
Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through
the mail, fax, etc.
Date: 7// ¥ 1/4y Plan Check/Permit Number:
❑ Response to Incomplete Letter #
❑ Response to Correction Letter #
lEr Revision # / after Permit is Issued
❑ Revision requested by a City Building Inspector or Plans Examiner
Project Name: 664,A'
Pa
l 2.?
U /cc✓ /�d (aQrnc,-4 4
!�/(47 -ek V4 or
V
Project Address: Z t 7 O x)47 C �-, `%'1«
Contact Person: /171,Q.P -e-c4�2 F-e ,(,i cATr4:Q Phone Number: 81 Er--'472D a-- 8 J 2-3
Summary of Revision:
ei' ,zi e, V'44-I (la B e> x re4 , _., f h G rr, e
e: �Ori=en C e> a c.e.e.5SorV ea
C.[ -14. 4c-,z % . . 'Cr. Z 3 *7
ate'
V6 / L 4 127 '-L. LnCrwiac_ "D
/es 3,1)
RECEIVED
riOFTU
Sheet Number(s):
"Cloud" or highlight all areas of revision including date of revisio
Received at the City of Tukwila Permit Center by:
entered in Permits Plus on
JUL 14 2008
elENTtr,
■applicationslforns- applications on line\revision submittal
rrra,rd• a_iz_�nne
Look Up a Contractor, Elec clan or Plumber License Detail
Washington State Department of Labor and Industries
General/Specialty Contractor
A business registered as a construction contractor with L &I to perform
construction work within the scope of its specialty. A General or Specialty
construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
License Information
License
AMERIMC071BH
Licensee Name
AMERICAN MECHANICAL CORP
Licensee Type
CONSTRUCTION CONTRACTOR
UBI
601433818
Ind. Ins. Account Id
53821001
Business Type
CORPORATION
Address 1
PO BOX 1136
Address 2
City
MONROE
County
SNOHOMISH
State
WA
Zip
982724136
Phone
2064676407
Status
ACTIVE
Specialty 1
BOILER/STEAM FIT/PROC PIPING
Specialty 2
PLUMBING
Effective Date
1/8/1993
Expiration Date
1/8/2009
Suspend Date
Separation Date
Parent Company
Previous License
Next License
Associated License
Business Owner Information
Name
Role
Effective Date
Expiration Date
KING, CHERI L
PRESIDENT
01/08/1993
KING, KELLY E
TREASURER
01/08/1993
•
Bond Information
Bond
Bond
Company
Name
Bond
Account
Number
Effective
Date
Expiration
Date
Cancel
Date
Impaired
Date
Bond
Amount
Received
Date
OLD
REPUBLIC
SURETY
Until
Page 1 of 2
https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= AMERIMC071 BH 06/11/2008
PLUMBING FIXTURE SCHEDULE
PLAN MARK
MANUFACTURER
MODEL NUMBER
NOTES
WC
AMERICAN STANDARD
#2168.100
C/W SUPPLY PIPING, ANGLE VALVE, WALL FLANGE AND FLEXIBLE RISER. (ZURN ZH- 8825- CR -LK) SEAT OLSONITE #46SSTL
LAV
ADVANCE
7 -PS -50
STAINLESS STEEL SINK, LEVER OPERATED DRAIN K-26, S.S. BASKET K -6, ADVANCE FAUCET K -9,
WH
A.O. SMITH
ELJF -10
10 -G.A. STORAGE CAPACITY, 3,0 INPUT, 208V. ELECTRIC WATER HEATER
FD
ZURN
ZN- 415 -65
CAST WITH DEEP SEAL TRAP AND 6" STRAINER
TP
PPP INC.
#PR -500
FULLY AUTOMATIC, ALL BRASS TRAP PRIMER VALVE, ACTIVATED BY A DROP IN BUILDING WATER PRESSURE, NO AJUSTMENT REQUIRED,
MODEL PRIME -RITE FOR 1 TO 4 TRAPS WITH DISTRIBUTION UNIT. MUST BE INSTALLED ON A FRESH COLD WATER LINE OF 1 1/2"
DIAMETER OR LESS, AS INDICATED ON DRAWINGS, OR REQUIRED BY PLUMBING CODE.
WCO
ZURN
--
WALL CLEAN OUT -CAST IRON CLEAN OUT TEE WITH BRONZE THREADED CLEAN OUT PLUG. PLUG TO BE GAS AND WATER TIGHT. WALL
ACCESS PANEL - ZURN #ZANB- 1460 -9 9 "x9" WALL ACCESS PANEL AND FRAME: SMOOTH NICKEL BRONZE SECURING LUGS.
VACUUM RELIEF VAVLE (VALVE
AND TEE ABOVE WATER HEATER)
TACO CX -15 EXPANSION TANK,
FDA AND ASME APPROVED
FOR POTABLE WATER.
•' • •
SCALE: N.T.S.
GENERAL PLUMBING NOTES
1. ALL PLUMBING INSTALLATIONS SHALL COMPLY WITH STATE AND LOCAL CODES.
2. PLUMBING CONTRACTOR SHALL MAKE CORRECTIONS IF WATER SUPPLY AND DRAINAGE FOR THE
BUILDING ARE REVERSED.
3. INSTALL ALL THREADED CLEANOUT PLUGS WITH PIPE DOPE TO ALLOW EASY REMOVAL IN THE
FUTURE.
4. IT WILL BE THE RESPONSIBIUTY OF THE PLUMBING CONTRACTOR TO INSURE THAT ITEMS TO BE
FURNISHED UNDER PLUMBING CONTRACT WILL FIT THE SPACE AVAILABLE - PLUMBING CONTRACTOR
SHALL MAKE NECESSARY FIELD MEASUREMENTS TO ASCERTAIN SPACE REQUIREMENTS, INCLUDING
THOSE FOR CONNECTIONS AND SHALL FURNISH AND INSTALL SUCH SIZES AND SHAPES OF
EQUIPMENT THAT ARE THE TRUE INTENT OF THE DRAWINGS AND SPECIFICATIONS.
5. GENERAL CONTRACTOR SHALL PROVIDE ALL OPENINGS IN WALLS, FLOORS, AND ROOF WITH
EACH CONTRACTOR RESPONSIBLE FOR VERIFYING LOCATION AND SIZES OF ALL OPENINGS
REQUIRED UNDER HIS CONTRACT, UNLESS NOTED OTHERWISE ON THE PLANS.
6. PLUMBING CONTRACTOR SHALL PROVIDE PRESSURE REDUCING VALVE, SWEAT TYPE, 30--60 PSIG
DISCHARGE RANGE WHERE REQUIRED BY LOCAL CODES.
7. ALL PLUMBING FIXTURES SHALL BE NEATLY CAULKED WITH SILICONE COMPOUND WHERE FIXTURE
MEETS WALL.
8. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ELECTRICAL AND CONTROL
CONNECTIONS TO PLUMBING EQUIPMENT WITH THE ELECTRICAL CONTRACTOR. SEE PLANS FOR
LOCATIONS OF JUNCTION BOXES, DISCONNECTS, AND CIRCUIT BREAKERS (PANEL BOARDS). TYPE,
SIZE AND NUMBER OF CONDUCTORS AND CONDUITS TO EQUIPMENT SHALL BE COORDINATED WITH &
VERIFIED BY THE ELECTRICAL CONTRACTOR. IN CASE OF PLUMBING EQUIPMENT CONNECTION TO A
CIRCUIT BREAKER, THE NUMBER AND SIZE OF CONDUCTORS AND CONDUIT SHALL CONFORM TO THE
LATEST NATIONAL ELECTRICAL CODE REGULATIONS. ALL MOTOR STARTERS, SWITCHES, CONTROL
DEVICES, ETC., PROVIDED BY THIS CONTRACTOR SHALL BE RECESSED IN THE WALLS, EXCEPT WHERE
THESE ITEMS ARE LOCATED IN MECHANICAL ROOMS. PROVIDE NAMEPLATES FOR ALL EQUIPMENT,
SWITCHES, CONTROL DEVICES, ETC.
9. PLUMBING CONTRACTOR SHALL SUPPLY AND INSTALL GAS PIPING IF SHOWN ON PLANS. ALL GAS
PIPING SHALL COMPLY WITH LOCAL CODES. PLUMBING CONTRACTOR SHALL MAKE FINAL
CONNECTIONS TO ALL EQUIPMENT. INSTALL REGULATORS AT EQUIPMENT WHERE REQUIRED BY
MANUFACTURER OR CUTS SUPPLIED BY FURNISHING CONTRACTOR.
10. PLUMBING CONTRACTOR SHALL INSTALL SHOCK ABSORBERS AT PLACES INDICATED ON THE
PLANS AND RISER DIAGRAM. SHOCK ABSORBERS SHALL BE PDI APPROVED.
11. ALL UNDERGROUND DRAINAGE, WASTE AND VENT PIPE SHALL BE CAST IRON OR PVC AS
ALLOWED BY LOCAL CODES. ALL ABOVE GROUND DRAINAGE, WASTE AND VENT PIPE SHALL BENT
12. CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR APPROVED FLOOR PLAN F(N
DIMENSIONS. DO NOT SCALE PLUMBING DRAWINGS.
13. CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING CONDENSATE DRAIN PIPING ON AIR
HANDLING UNITS. COORDINATE WORK WITH MECHANICAL CONTRACTOR.
14. CONTRACTOR SHALL INSTALL WATER PIPING SO THAT PIPE JOINTS ARE NOT UNDER FLOOR
SLAB.
15. PIPE INSULATION SHALL BE CONTINUOUS THROUGH WALLS OR FLOOR.
16. CONTRACTOR SHALL TEST SOIL, WASTE AND VENT SYSTEMS WITH PEPPERMINT. ALL MECHANICAL
SYSTEMS SHALL BE RUNNING WHILE THESE TESTS ARE BEING MADE.
CONTRACTOR SHALL FURNISH A CERTIFICATE OF COMPLIANCE AND ACCEPTANCE OF
THESE TESTS.
17. CONTRACTOR SHALL INSULATE ALL UNDER SLAB HOT WATER PIPING WITH 1" RIGID URETHANE
FOAM INSULATION AND 1" CLOSED CELL RUBBER INSULATION, WITH FIRE RETARDANT COATING ON
ALL HOT WATER AND RETURNS LINES ABOVE SLAB. INSULATE ALL COLD WATER LINES ABOVE SLAB
WITH 1/2" CLOSED CELL RUBBER FIRE RETARDANT INSULATION.
18. ANY DEVIATIONS FROM SPECIFIED PLUMBING FIXTURES AND TRIM IN FIXTURE SCHEDULE SHALL
BE APPROVED PRIOR TO SUBMITTAL FROM THE ALDO'S PROJECT MANAGER.
19. ALL INDIRECT WASTE LINES SHALL HAVE A MINIMUM OF 2" VERTICAL AIR GAP AT FLOOR SINK,
DRAIN OR HUB. FLOOR SINKS, DRAINS OR HUBS SHALL EXTEND A MINIMUM 1" ABOVE FINISHED
FLOOR WHEN SERVING INDIRECT DRAINS.
20. VACUUM BREAKERS SHALL BE INSTALLED ON ALL HOSE BIBBS AND HYDRANTS. VACUUM
BREAKERS /BACK FLOW PREVENTORS TO BE INSTALLED AT ANY POINT WHERE THERE IS DANGER OF
THE NON POTABLE WATER SYSTEM COMING IN CONTACT WITH THE PORTABLE WATER SYSTEM OR
ANY DANGER OF BACK FLOW. COORDINATE WITH LOCAL INSPECTOR.
21. ALL PLUMBING WORK SHALL BE COORDINATED WITH OTHER PROJECT CONTRACTORS BEFORE
INSTALLATION.
22. USE TYPE "K" SOFT DRAWN COPPER UNDER SLAB.
23. ALL WATER DISTRIBUTION PIPE ABOVE GROUND SHALL BE COPPER OR COPPER ALLOY TUBING.
E
WC
TO TRAP PRIMER
CONNECTION AT FD
EJ
`- PROVIDE BALL VALVE.
UNION
LAV
WATER RISER DIAGRAM
10 GALLON WATER HEATER ABOVE
TOILET CEILING. PROVIDE 3"
DEEP GALV PAN W /SOLDERED
SEAMS.
TERMINATE INDIRECTLY
INTO FLOOR DRAIN
ROUTE AUX. DRAIN TO APPROVED
RECEPTOR SUCH AS TATTLETAIL DRAIN
ETC. WATER HEATER T & P AND DRAIN
PAN CANNOT CAUSE TRIPPING HAZARD.
VERIFY EXACT LOCATION IN FIELD.
( F�
EP
T
EP
WCO
EXTEND NEW 4" 5S TO EXISTING
SYSTEM, VERIFY EXACT LOCATION,
FLOW AND DEPTH.
} WC
PLUMBING PLAN
SCALE: 1 /4" = 1 -0"
WCO
4"
PROVIDE AND INSTALL
4" V.T.R.
3" FD
W /TRAP
PRIMER
LAV
y
f
7 A
WASTE RISER DIAGRAM
3 SCALE: N.T.S.
EXTEND NEW 4" SS TO EXISTING
SYSTEM, VERIFY EXACT LOCATION,
FLOW AND DEPTH.
Consultant
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees.
FILE C
Permit No
PY
Issues and Revisions
No. Date
1 03.31.08
Plar review approval is subject to errors and omissions.
Approval of construction documents does not ui
the violation of any adopted code or ordinanc . Re!
of approved 9 Co conditions is acknowledged:
4 zi
Date:,
By
City of Tukwila
BUILDING DIVISION
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAY - 2008
City Of Tukwila
BUI � N D I N
P& Sze
2887 Southcenter Mall
Tukwila, WA 98188
aaith co.
1725 westlake ave. n.
suite 210
seattle, washington 98109
206.838.5485 p
206.713.4076 m
206.464.0700 f
ksmith @smithco.org
http: / /www.smithco.org/
Consultant Registration
Scale AS NOTED
'SEPARATE PERMIT
REQUIRED FOR:
Mechanical
Mir Electrical
❑ Plumbing
0 Gas Piping
City of Tukwila
BUILDING DIVISION
P -1
Issues
Project Number 02008018.00
RECEIVED Templat 4.3 (120101)
PERMIT
6294
Description PLUMBING PLAN
Computer File CW05- 2008— P1,DWG
Architect Registration
REGISTERED
ARCFWJECT
KEI
STATE OF WASHINGTON
Project Name WESTFIELD SOUTHCENTER MALL
By Check
All ideas, designs, arrangements, and plans indicated or
APR 2 4 2008
represented by this drawing are owned by and the property of
smith co. Ilc and were created, evolved, and developed
PERMIT CENTER for use on and in connection with the specified project. None of
such ideas, designs, arrangements or plans shall be used
by or disclosed to any person, firm, or corporation for any
purpose whatsoever without the written permission of smith co. Ilc.
K LS