Loading...
HomeMy WebLinkAboutPermit PG08-137 - WESTFIELD SOUTHCENTER MALL - EXPRESSEXPRESS 1070 SOUTHCENTER MALL PGO8-137 Parcel No.: 6364200010 Address: Suite No: Citylf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PLUMBING /GAS PIPING PERMIT 1070 SOUTHCENTER MALL TUKW Permit Number: Issue Date: Permit Expires On: PG08 -137 08/04/2008 01/31/2009 Tenant: Name: EXPRESS Address: 1070 SOUTHCENTER MALL , TUKVVILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: TIM SCHENK Address: 1120 E 80 ST , BLOOMINGTON MN Contractor: Name: GREENWOOD CONSTRUCTION COMPLANY Address: 12637 S 265 WEST STE 100 , DRAPER UT Contractor License No: GREENCC973MW Phone: Phone: 800 541 -0821 Phone: Expiration Date: 07/10/2009 DESCRIPTION OF WORK: PLUMBING FOR TI: NEW WATER CLOSETS, LAVATORIES, DRINKING FOUNTAINS AND WATER HEATERS. Value of Plumbing /Gas Piping: Fees Collected: $15,000.00 $308.00 Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 FIXTURE TYPE AND QUANTITY Plumbing (cont.) 0 Building sewer and each trailer park sewer 1 0 Rain water system - per drain (inside bldg) 0 0 Water heater and/or vent 2 0 Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 2 grease interceptors 0 0 Repair or alteration of water piping and/or water 3 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 2 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 1 0 Medical gas piping (6 +) inlets /outlets 0 1 Gas Piping 0 Gas piping outlets (0 -5) 0 2 Gas piping outlets (6 +) 0 * *continued on next page ** doc: UPC -10/06 PG08 -137 Printed: 08 -04 -2008 City ofTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: PG08 -137 Issue Date: 08/04/2008 Permit Expires On: 01/31/2009 Permit Center Authorized Signature: Date: 8-4 -00 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not p e to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of ork am authorized to sign and obtain this plumbing /gas piping permit. Signature: L %A Print Name: a/ ft 1° Date: IP-. 9'. This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -10/06 PG08 -137 Printed: 08 -04 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: EXPRESS • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS 1070 SOUTHCENTER MALL TUKW Permit Number: Status: Applied Date: Issue Date: PG08 -137 ISSUED 04/29/2008 08/04/2008 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. * *continued on next page ** doc: Cond -10/06 PG08 -137 Printed: 08 -04 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: 2)a7 Print Name: Date: ordinances governing or local laws regulating doc: Cond -10/06 PG08 -137 Printed: 08 -04 -2008 � PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG08 -137 DATE: 04 -29 -08 PROJECT NAME: EXPRESS SITE ADDRESS: 1070 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Bulkng'DI'vi ��sion Public WpFks 114,6 6 Fire Prevention n Planning Division Structural Permit Coordinator [DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 05 -01 -08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: Structural Review Required No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 0529-08 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documentshouting slip.doc 2 -28 -02 1 r • CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Building Permit No. Mechanical Permit No. ,vafb -122 Plumbing /Gas Permit No. Pb — Public Works Permit No. ?(/-101 Project No. For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: (o3Co420 - 1 0 Site Address: i07 0 .* ce - ke r f` la. \\ Tenant Name: g'xi-yCec, Property Owners Name: kci;eaci. o coa -ia'r1 Mailing Address: IIGO t aN a\S\n�'C e.. Rea1/4.1.ievaect ; LAS P rc \es, CR L1 City Suite Number: g32 Floor: 1 New Tenant: ® Yes I 1.. No State Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: j: yr, Day Telephone: goo k ;41- izgzi Mailing Address: 112.c) B1000rv,i MIV SS4W State Zip E -Mail Address: onnSe cter-pne,. Cnyv'. City Fax Number: 5'z JgS-zj - �$QOCj GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: T. IN. Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: City Day Telephone: Fax Number: Expiration Date: State Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: S1l\\'e S'\OCk Prce9n;itec±S i 1rle.. Mailing Address: (pl3r & inl.,NCui 1OOC:Ai 1t?S$tr e It \%e.l Oki 1.430i3 Ti J City State Contact Person: Se fi.XV ∎e— KP ■-ih Day Telephone: Cip 14 ISyS - 4&-St) E -Mail Address: �i-1-4n oe. .\r►ry ShcxSG • cowl Fax Number: t t4 ) S'4S - 4 SSS' Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: SaltwerrNSVIOCt �Yl ® n e..e ci Yvq , TIC- . Mailing Address:lol3f) .. v J . C�► 9' Contact Person: ep\ Yw Ve__ ‘<€.1 \ E -Mail Address: SKI FYI @ Sir\ep c vi Q:WppticationsWonns- Applications On Lineli -2006 - Permit Application.doc Revised: 9 -2006 bh City State Zip Day Telephone: Cag IS4.S-145-SF Fax Number: (7l -% I S4S - 4SSS Page 1 of 6 BUILDING PERMIT INFOION - 206 - 431 -3670 0 Valuation of Project (contractor's bid price): $ 25; 0DO Scope of Work (please provide detailed information): Existing Building Valuation: $ rn : 're-a -coo s Will there be new rack storage? ❑ Yes ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the found- on of all structures, plus any decks o `- 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the follow g: Lot Area (sq ft): loor area of principal dwelling: *Provide documentation that show at the principal owner lives in one of the dwellings his or her primary residence. Floor area of accessory dwelling: Number of Parking Stalls Provided: andard: Compact: Will there be a change in use? ❑ Yes ® No If `yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: Handicap: Sprinklers M Automatic Fire Alarm ❑ None ❑ �'� ►ther (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ■ Yes IN No If "yes', attach list of materials and storage locations on a separate 8 -1/2" x II" paper including quantitie and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q: 1ApplicationsTorms- Applications On Line\3.2006 - Permit Application.doc Revised, 9 -2006 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of onstruction per IBC Type of Occupancy per IBC l st Floor ', 31 SS, 931 2nd Floor 3`a Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the found- on of all structures, plus any decks o `- 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the follow g: Lot Area (sq ft): loor area of principal dwelling: *Provide documentation that show at the principal owner lives in one of the dwellings his or her primary residence. Floor area of accessory dwelling: Number of Parking Stalls Provided: andard: Compact: Will there be a change in use? ❑ Yes ® No If `yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: Handicap: Sprinklers M Automatic Fire Alarm ❑ None ❑ �'� ►ther (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ■ Yes IN No If "yes', attach list of materials and storage locations on a separate 8 -1/2" x II" paper including quantitie and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q: 1ApplicationsTorms- Applications On Line\3.2006 - Permit Application.doc Revised, 9 -2006 bh Page 2 of 6 • • PLUMBING AND GAS PIPING PERMIT INFORMATION — 206 - 431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: T. P,. b. Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Plumbing work (contractor's bid price): $ 161 b ®O Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): Nu,0 tec—c1)seAS , owakt)c;.e s 6.t'•■∎,r_∎ Building Use (per Int'l Building Code): re) Occupancy (per Int'l Building Code): rfl Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Z Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain 'dc 3 Sinks Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory 2- Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and /or vent Z Additional medical gas inlets /outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and /or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets /outlets for specific gas Q:\Applications\Forms- Applications On Linel3 -2006 - Permit Application.doc Revised: 9 -2006 bh Page 5 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHOR ZED AGENT: Signature: Print Name: --rver, SCiner, - Date: `i Q 2.4 Day Telephone: '0D1S -0$Z L Mailing Address: i V a0 Q—o-S* dirt SiTQ r ik2t1- g \\OrM■ hCoot-fc r) ("t N SSA ZQ Cityj State Zip Date Application Accepted: I yi I 24 1,912 Date Application Expires: 1 01 2,1 ` Staff Initials: /`� Q:1Applications\Fonns- Applications On Line13 -2006 - Permit Application.doc Revised: 9 -2006 bh Page 6of6 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: PG08 -137 Address: 1070 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 04/29/2008 Applicant: EXPRESS Issue Date: Receipt No.: R08 -02824 Initials: WER User ID: 1655 Payment Amount: $261.00 Payment Date: 08/04/2008 08:56 AM Balance: $0.00 Payee: GREENWOOD CONSTRUCTION TRANSACTION LIST: Type Method Descriptio Amount Payment Check 97419 261.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES PLUMBING - NONRES 000/345.830 3.00 000.322.103.00.0 258.00 Total: $261.00 5621 08/04 9710 TOTAL 261.00 doc: Receiot -06 Printed: 08 -04 -2008 City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us SET RECEIPT RECEIPT NO: R08 -01394 Initials: JEM User ID: 1165 Payee: ELDER -JONES Payment Date: 04/29/2008 Total Payment: 2,859.25 SET ID: S000001014 SET TRANSACTIONS: Set Member Amount D08 -235 EL08 -486 M08 -122 2,346.50 300.50 165.25 47.00 TOTAL: 2,859.25 TRANSACTION LIST: Type Method Description SET NAME: Trap set/Initialized Activities Payment Check 51321 ACCOUNT ITEM LIST: Description TOTAL: Amount 2,859.25 2,859.25 Account Code Current Pmts ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES 000.345.832.00.0 300.50 000/345.830 2,558.75 TOTAL: 2,859.25 1770 04/29 9711 TOTAL 2859.25 n, or•armc no INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD �� -13 i4.1 Retain a copy with permit PERMIT NO. Pro t: EiY ► SS Type of Inspection: r-1 IV 11 6 - (J (u-wt LI ddress: th —2 v ym A l Date Called: — Special Instructions: Date Wanted: IL.)— r6 -0e, C.m� p.m. Requester: Ph '3a 0 No3 -cr2( 00 IQ 'igApproved per applicable codes. Ei Corrections required prior to approval. COMMENTS: Pe9C►M tr (1CrvIA if° /11 lJ►`i ( Date: )6- I6 -(4_1- 00 REINSPECTION FE • EQUIREQ. Prior to inspection, fee must be at 6300 Southcenter Bl 4., Suite 100. Call to schedule reinspection. Rece . t No.: Date: rJL.td9C06- an .�.dtA9R dlbl.�a._a__ INSPECTION RECORD Retain a copy with permit INSPECT! • NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION Y-- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Project: Type of Inspection: Addre s: i i Date Called: Special Instructions: Date Wanted: 9 7 Requester: Phone No: pproved per applicable codes. D Corrections required prior to approval. 5 COMMENTS: Inspector: Date: 94.e..3ff ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD q ; /17 J Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ''e- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367`0 Project: Type 13 Inspect,* t Ad r s: /U 7v $( / / Date Called: Special Instructions: Date Want *� l I G� a m ^ Requester: Phone No: Approved per applicable codes. 0 Corrections required prior to approval. epif/ COMMENTS: Date: r, oy $58.00 REF SPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: 'Date: SPEC 1 TION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit PERMIT N l (206)431 -36 Project: e >"/*" '91) Type of Inspection: w tkret �1 V" 1 Address/ • a7a s(7!y/ ate Called: Special Instructions: Date 7.teci4._ air a.m. cry Requester: Phone No: ElApproved per applicable codes. 0 Corrections required prior to approval. COMMENTS: Pry &14•/";trf--- %A ./ ./7/. "41- ---"" Date: $58.00 REI - • ECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: Untitled Page • • General /Specialty Contractor A business registered as a construction contractor with Lai to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. GREENWOOD CONSTRUCTION COMPANY Business and Licensing Information Name GREENWOOD CONSTRUCTION COMPANY Phone 8015760550 Address 12637 SO 265 WEST STE 100 Suite /Apt. City State Zip County DRAPER UT 84065 OUT OF STATE Business Type CORPORATION Parent Company UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Separation Date Previous License Next License Associated License Specialty 1 Specialty 2 602306206 ACTIVE GREENCC973MW CONSTRUCTION CONTRACTOR 7/10/2003 7/10/2009 GENERAL UNUSED Business Owner Information Name Role Effective Date Expiration Date STONE, MICHAEL D PRESIDENT 07/16/2003 Bond Amount FORBUSH, ALLISON L SECRETARY 07/16/2003 JR6290 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 USFEtG CO JR6290 06/27/2003 Until Cancelled $12,000.00 07/10/2003 Insurance Information Page 1 of 2 Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date TRAVELERS https:// fortress .wa.gov /lni/bbip/Detail. aspx ?License = GREENCC973MW 08/04/2008 • -- DIVISION 22 SECTION 22000 - PLUMBING A. SCOPE OF WORK 1. THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL WORK FOR THE PLUMBING SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: A. B. C. D. E. F. G. 2. BEFORE STARTING WORK, THIS CONTRACTOR SHALL EXAMINE THE ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL PLANS AND SPECIFICATIONS TO SEQUENCE, COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE PLUMBING SYSTEM, MATERIALS, AND EQUIPMENT WITH OTHER CONTRACTORS TO AVOID INTERFERENCES AND CONFRONTATIONS. 3. RELOCATION OF EXISTING WATER, GAS, WASTE, VENT, OR DRAINAGE LINES TO FACILITATE STORE DESIGN CRITERIA MUST BE INCLUDED IN BID PROPOSAL B. EQUIPMENT AND INSTALLATION 1. REFER TO PLANS FOR SCHEDULES OF EQUIPMENT AND FIXTURES. AMERICAN STANDARD, KOHLER AND CRANE MAY BE CONSIDERED WITH APPROVAL FROM ESD&C PROJECT MANAGER. 2. SANITARY PIPING A. C. B. INSULATE ALL HORIZONTAL RUNS OF PIPING LOCATED IN CEILING SPACES, WHEN APPLICABLE. INSULATION TO BE AS SPECIFIED FOR WATER PIPING. CONDENSATE PIPING SHALL BE TYPE DRAWN COPPER TUBE WITH 95-5 TIN-ANTIMONY SOLDERED JOINTS AND WROUGHT COPPER FITTINGS WITH DIELECTRIC SEPARATION BETWEEN DISSIMILAR METALS. 3. POTABLE WATER PIPING SHALL BE AS FOLLOWS: A. BELOW GRADE: TYPE 'K', ANNEALED TYPE TEMPERED COPPER TUBE FOR PIPE SIZES 2 INCHES AND B. ALL OTHER: SULEL MI A UPp J EA T T s U . BE WITH WROUGHT COPPER FITTINGS AND 95-5 TIN- 4. PIPING OF DISSIMILAR METALS MUST BE DIELECTRICALLY SEPARATED. ANTIMONY SOLDER. 5. GENERALLY, SANITARY AND POTABLE WATER TAPS WILL BE PROVIDED BY THE LANDLORD. FIELD VERIFY EXACT CONNECTION POINTS PRIOR TO SUBMITTING BID. NOTIFY THE LSD&C PROJECT MANAGER, IF CONDITIONS ARE NOT AS SHOWN ON THE PLANS OR AS STATED IN THE SPECIFICATIONS. CONTRACTOR MUST VERIFY THE OPERABILITY OF ENTIRE SYSTEM PRIOR TO TIE-IN AS FOLLOWS: A. SNAKE SANITARY TO MALL MAIN AND REPORT ANY BLOCKAGE. B. TEST WATER PRESSURE TO INSURE MINIMUM PSI MATCHES MOST DEMANDED BY EQUIPMENT SUPPLIED. 6. INSULATE ALL HOT WATER, COLD WATER AND CONDENSATE PIPING WITH 1" THICK (K=0.23 0 751) PIPE INSULATION WITH AN ALL SERVICE JACKET TO MEET LOCAL CODES AND UL FLAME SPREAD AND SMOKE DEVELOPED RATINGS. 7. INSULATE THE TRAP, SANITARY AND SUPPLY PIPES UNDER LAVATORY WITH 1/2" ARMSTRONG "ARMAFLEX" PIPING INSULATION OR TRUEBRO MODEL 102W "HANDI LAV GUARD" INSULATION KIT. 8. INSTALL ALL NECESSARY PIPE HANGERS, SADDLES, AND CARRIERS TO PROPERLY SUPPORT ALL PIPING AND FIXTURES. HANGERS SHALL SUIT TYPE OF PIPING PROVIDED AND BE SPACED AT A MAXIMUM SPAN OF 5 FEET. PROVIDE SWAY AND SEISMIC BRACING WHERE REQUIRED BY CODES. 9. STERILIZE WATER SYSTEM IN ACCORDANCE WITH LOCAL CODES. 10. CLEANOUTS AND FLOOR DRAINS SHALL BE INSTALLED PER LOCAL CODES. WALL COVERS ARE TO BE STAINLESS STEEL AND FLOOR COVERS ARE TO BE BRASS, UNLESS OTHERWISE SPECIFIED. PROVIDE FLOOR COVERS WITH INSET AREA FOR CARPETED LOCATIONS. ALL CLEANOUT LOCATIONS SHALL BE APPROVED BY THE ESD&C PROJECT MANAGER. 11. ESCUTCHEONS SHALL BE CHROME PLATED, SIZE AS REQUIRED, AND PLACED AT ALL PIPE PENETRATIONS AT WALLS, FLOORS AND CEILINGS IN FINISHED AREAS. 12. LEAKAGE TESTS SHALL BE PER LOCAL CODES MINIMUM AS FOLLOWS: A. TEST WATER PIPING AT 100 PSIG FOR SIX HOURS. B. TEST DRAIN, WASTE, VENT PIPING BY A 10' WATER COLUMN FOR TWO HOURS 13. FLASHING SHALL BE SEALED WATERTIGHT AND PERFORMED IN ACCORDANCE TO THE LANDLORD'S CRITERIA. USE A LANDLORD APPROVED ROOFING CONTRACTOR, WHERE APPLICABLE. 14. PROVIDE WATER METER AND REMOTE READER PER LANDLORD'S CRITERIA OR LOCAL UTILITIES REQUIREMENTS, IF APPLICABLE. REFER TO PLANS TO DETERMINE IF WATER METER IS REQUIRED. END OF SECTION 15200 AD ADA AFF AP CD CFM CI CO CONT CONTR COTG CW DET DF DL DS DTR DWG COMPLETE SANITARY PIPING SYSTEMS OF WASTE, DRAINS, AND VENTS. COMPLETE COLD AND HOT WATER PIPING SYSTEMS, APPURTENANCES AND INSULATION. FIXTURES AND EQUIPMENT AS SCHEDULED. COMPLETE NATURAL GAS OR PROPANE PIPING SYSTEMS (AS APPLICABLE, REFER TO PLANS) CONDENSATE PIPING SYSTEMS (AS APPLICABLE, REFER TO PLANS). TESTS AND ADJUSTMENTS. SUBMIT A COMPLETE SET OF REPRODUCIBLE AS-BUILTS. WASTE, DRAIN AND VENT PIPING SHALL BE SERVICE WEIGHT CAST IRON SOIL PIPE. VENT PIPING ABOVE FLOOR 2" OR SMALLER MAY BE GALVANIZED STEEL ALTERNATE PIPING MATERIALS ARE ACCEPTABLE AS A SUBSTITUTION WHEN THEIR USE IS PERMITTED BY THE LANDLORD, LOCAL CODES AND BUILDING DEPARTMENT OFFICIALS AND DOES NOT AFFECT OTHER TRADES. SUBSTITUTIONS MUST BE LISTED AND QUALIFIED IN BID. NO PLASTIC PIPING ALLOWED. ACCESS DOOR AMERICAN DISABILITY ACT ABOVE FINISHED FLOOR ACCESS PANEL CEILING DIFFUSER OR CONDENSATE DRAIN CUBIC FEET PER MINUTE CAST IRON CLEANOUT CONTINUE CONTRACTOR CLEANOUT TO GRADE COLD WATER DETAIL DRINKING FOUNTAIN DOOR LOUVER DREAMSTEAMER DOWN THRU ROOF DRAWING (E) EXISTING EWC ELECTRIC WATER COOLER FCO FLOOR CLEANOUT FCU FAN COIL UNIT ED FLOOR DRAIN FPS FEET PER SECOND FS FLOOR SINK GAL GALLONS GC GENERAL CONTRACTOR GPM GALLONS PER MINUTE HB HD HP HW HOSE BIBB HEAD HORSEPOWER HOT WATER INV INVERT ABBREVIATIONS - PLUMBING LAV LB LF MECH MFR MTD MTR (N) N.C. N.I.C. N.O. N/A NTS PD PLBG POC PRV PSI (R) RD RPBP RPM LAVATORY POUND LINEAL FEET MECHANICAL MANUFACTURER MOUNTED MOTOR NEW NORMALLY CLOSED NOT IN CONTRACT NORMALLY OPEN NOT APPLICABLE NOT TO SCALE PUMP PRESSURE DROP PLUMBING POINT OF CONNECTION PRESSURE REDUCING VALVE POUNDS PER SQUARE INCH RELOCATE ROOF DRAIN REDUCED PRESSURE BACKFLOW PREVENTER REVOLUTION PER MINUTE SCH SCHEDULE SOV SHUT-OFF VALVE OR SCHEDULE OF VALVE UH UON UTR VTR VENT THRU ROOF WC WCO WG WH WHA WT UNIT HEATER UNLESS OTHERWISE NOTED UP THRU ROOF WATER CLOSET WALL CLEANOUT WATER GAUGE WATER HEATER WATER HAMMER ARRESTER WEIGHT ITEM PLUMBING FIXTURES & TRIM DRINKING FOUNTAIN AND ASSOCIATED ACCESSORIES. SEWER AND VENT PIPING TANK WATER HEATER DOMESTIC HOT AND COLD WATER PIPING CONDENSATE DRAIN PIPING SECOND COND. DRAIN PIPING GAS PIPING COND. DRAIN PUMP DREAMSTEAMER FLOOR DRAINS, CLEAN OUTS, WATER HAMMER ARRESTORS, ETC. DREAMSTEAMER DRAIN PIPING AS-BUILT DRAWINGS INSTANTANEOUS WATER HEATER FURNISHED BY LSD&C VENDOR LD DS LANDLORD CONTR. GC GC GC GC GC GC GC GC GC GC INSTALLED BY LANDLORD CONTR. GC GC GC GC GC GC GC GC GC GC OTHER GC N/A RE-USE EXISTING • REMARKS PLUMBING RESPONSIBILITY SCHEDULE PLUMBING RESPONSIBILITY SCHEDULE CD EXISTING WASTE OR SAN. SEWER CONDENSATE DRAIN 1. THESE PLANS MAY BE USED FOR CONSTRUCTION ONLY AFTER APPROVAL IS OBTAINED FROM THE BUILDING DEPARTMENT PLUMBING PLAN CHECK DIVISION AND THAT DIVISION'S STAMPED APPROVAL AND AUTHORIZED SIGNATURE APPEAR ON THE PLANS. 2. COORDINATE ALL WORK WITH ALL TRADES INCLUDED BUT NOT LIMITED TO ELECTRICAL, FIRE PROTECTION, MECHANICAL AND STRUCTURAL CONTRACTORS. INSTALL ALL WORK TO CLEAR NEW AND EXISTING ARCHITECTURAL AND STRUCTURAL MEMBERS. NO ITEM SUCH AS PIPE, DUCT, ETC. IS TO BE IN CONTACT WITH ANY EQUIPMENT. 3. REFER TO ARCHITECTURAL DRAWINGS FOR DEMOLITION WORK. 4, REFER TO ARCHITECTURAL DRAWINGS FOR EXACT FIXTURE LOCATION. 5. CONTRACTOR SHALL PROVIDE CUT SHEETS TO LSD&C FOR ALL EQUIPMENT AND DEVICES FURNISHED BY THE CONTRACTOR THAT DEVIATE FROM SPECIFIED ITEM FOR REVIEW AND APPROVAL PRIOR TO THE PURCHASE OF ANY SUCH EQUIPMENT OR DEVICES. 6. THE PLUMBING CONTRACTOR SHALL BE RESPONSIBLE TO FIELD VERIFY THE EXACT LOCATIONS, SIZES, INVERTS AND CONDITION OF EXISTING SANITARY WASTE PIPING BELOW SLAB, VENT PIPING ABOVE CEILING AND UP THROUGH ROOF AND DOMESTIC COLD WATER SUPPLY PIPING TO TENANT'S DEMISED PREMISES PRIOR TO SUBMITTING HIS BID. NO ADDITIONAL COMPENSATION WILL BE MADE FOR ANY EXTRAS DUE TO CONTRACTOR'S FAILURE TO VISIT THE JOB SITE AND/OR FAILURE TO PREDETERMINE ALL EXISTING CONDITIONS BEFORE SUBMITTING HIS BID. 7. ACCESS TO ALL COMPONENTS AND EQUIPMENT MUST BE PROVIDED TO MEET CODE AND SERVICE/MAINTENANCE EASE. 8. THE CONTRACTOR SHALL VERIFY WITH LOCAL CODES AS TO THE REQUIREMENT/INSTALLATION OF ANY "WATER SAVING" DEVICES TO THE PLUMBING FIXTURES. (EXAMPLE: TOILET, FAUCETS, ETC.). 9. PLUMBING SYSTEM SHALL BE PRESSURE TESTED AND STERILIZED PER LANDLORD'S CRITERIA AND LOCAL AUTHORITY. 10. UPON COMPLETION OF THE WORK, CONTRACTOR SHALL ENSURE THE PROPER WORKING ORDER OF THE SYSTEM(S) AND MAKE ANY ADJUSTMENTS AS REQUIRED. SHREMSHOCKA ENGINEERING, INC. 6130 S. .AD WESTERVILLE, OH 43081 614-545 T REQUIRED BY: DATE ISSUED: DESIGNED BY: DRAWN BY: CHECKED BY: INDICATES NO REVISION TO THIS SHEET 0 • z Z ; .9 LU LU 0 11: 1 '47 0 2 HNi • " 11 ! ! • LLi C OOL-LU =0 z !34 ° ce .T1 Y2 5U 0E1=L61 LU 0 c o .77 ° 55-N66-3LAiu REVISIONS: (NI 0 c0 U O) - 0 00 0 0 0- Do • w 0 IS- z 0 0(7) w ti c DATE 04/18/2008 PMK PMK TIP PLUMBING SPECIFICATIONS DRAWING NUMBER: PLUMBING GENERAL NOTES 1. UNLESS OTHERWISE SPECIFIED, CONTRACTOR SHALL PROVIDE ALL NECESSARY EQUIPMENT, MATERIAL, LABOR AND SUPERVISION NECESSARY TO COMPLETE THE PLUMBING WORK IN ACCORDANCE WITH THE SPECIFICATIONS AND STANDARDS. 2. FIELD VERIFY EXACT SIZE AND LOCATION OF EXISTING WASTE PIPING BELOW SLAB, VENT PIPING ABOVE CEILING AND UP THROUGH ROOF AND COLD WATER SUPPLY PIPING ABOVE CEILING PRIOR TO COMMENCEMENT OF ANY WORK. AFTER INSTALLATION AND FINAL CONNECTION OF NEW WASTE PIPING BELOW SLAB, BACK FILL AND PATCH IN ACCORDANCE WITH THE LANDLORD'S CRITERIA REGARDING SUCH WORK. 3. CONTRACTOR SHALL FURNISH AND INSTALL ALL OF THE NECESSARY PLUMBING FIXTURES (SEE PLUMBING RESPONSIBILITY SCHEDULE ON THIS SHEET) TO SERVE THE TENANT'S DEMISED PREMISES AND MAKE NECESSARY INSTALLATION OF DOMESTIC WATER AND SEWER PIPING FROM TENANT'S DEMISED PREMISE TO CONNECTION PROVIDED BY LANDLORD. 4. SANITARY VENTS SHALL BE ROUTED TO THE EXISTING LANDLORD'S POINT OF CONNECTION WITHIN THE TENANT'S DEMISED PREMISES OR TO A POINT APPROVED BY LOCAL AUTHORITY. THE CONTRACTOR SHALL PROVIDE A CAPPED TEE FOR POSSIBLE FUTURE CONNECTION (IF REQUIRED BY THE LANDLORD). CONTRACTOR SHALL COORDINATE ALL ROOF PENETRATIONS WITH THE LANDLORD'S ROOFING CONTRACTOR, AS REQUIRED. VENT THRU ROOF SHALL BE AT LEAST 15 FEET AWAY FROM A/C UNIT FRESH AIR INTAKE. 5. SEAL AROUND ALL PIPES PENETRATING FIRE SEPARATIONS WITH LISTED AND APPROVED FIRE SEAL MATERIAL. ONLY LISTED AND APPROVED SEALANTS AND METHODS FOR THE SPECIFIC USE WILL BE PERMITTED. 6. THE CONTRACTOR SHALL INSTALL ALL TOILET FIXTURES IN ACCORDANCE WITH ALL CODES AND AS REQUIRED BY LANDLORD'S CRITERIA. CONTROLS FOR FLUSH VALVES SHALL BE MOUNTED ON THE WIDE SIDE OF THE WATER CLOSET AND NO MORE THAN 44" A.F.F. 7. THE CONTRACTOR SHALL ENSURE THAT ALL SLAB PENETRATIONS WITHIN THE TENANT'S DEMISED PREMISES ARE PROPERLY SEALED AND REMAIN WATERTIGHT TO PREVENT ANY POSSIBLE DAMAGE TO OTHER TENANTS AND/OR TO THE BUILDING. FAILURE TO DO SO SHALL BE AT THE RISK AND SOLE EXPENSE OF THE CONTRACTOR. 8. ALL MATERIAL SHALL BE NEW AND OF COMMERCIAL GRADE, AND BEAR UNDERWRITER'S LABORATORIES AND UNION LABELS WHERE SUCH LABELING APPLIES. 9. PLUMBING CONTRACTOR TO FIELD VERIFY PROPER SLOPE OF EXISTING SEWER TO MAIN SEWER PRIOR TO ANY NEW PLUMBING INSTALLATION. 10. PLUMBING CONTRACTOR MUST VISIT THE JOBSITE TO BECOME FAMILIAR WITH MAJOR ITEMS SUCH AS STRUCTURAL ELEMENTS AND OTHER EXISTING JOB CONDITIONS THAT MAY AFFECT THE WORK. ADDITIONALLY, PLUMBING CONTRACTOR SHALL VERIFY EXACT LOCATIONS AND DIMENSIONS OF SUCH ITEMS AS WASTE, VENTS, WATER LINES, ETC. 11. PLUMBING CONTRACTOR TO FAMIUARIZE AND FOLLOW SPECIFICATIONS AND DETAILS CONTAINED IN DESIGN CRITERIA OF TENANT HANDBOOK. 12. PLUMBING CONTRACTOR TO CLEAR ALL EXISTING AND NEW DRAIN LINES AND FIXTURES, PRIOR TO TURNING OVER SPACE TO TENANT. 13. PLUMBING CONTRACTOR SHALL PROVIDE ACCESS TO VALVES, TRAP PRIMERS, ETC. INSTALLED BEHIND WALLS, FLOORS OR CEILINGS. 14. NO PLASTIC PIPING ALLOWED. FIEF Permit tioltiralLitl Plar review approval is subject to errors and omissions. Approva! of construction documents does not aulhorize the violation of any adopted code or ordinance. Receipt Of approved Field Copy and g.ftihs Is acknowledged: By Date: City of Tukwila EILIILOING DIVISION MOW; No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. SEPARATE FERMI REQUIRED FOR: of Mechanical 6 14 P E l l u e rn ct b ric in a g i BuiCL * FOR CODE COMPLIANCE PPROVED MAY - 8 T PU8 ...___ _ ClAy Of Tukwila . . BUILDING DIV.150:: Rua:7E crry OF TI IKVVILA APli 2 9 i11118 PERMIT CEA NTS 00NP011CONOTE B PLUMBING SPECIFICATION NTS 00NP011,10SPEC F ITEM I WC I LAV-1 I UR I I OF 1 I MS I TP FD I WHA I w co FCO FIXTURE WATER CLOSET TANK TYPE LAVATORY UNDERCOUNTER URINAL WALL MOUNTED DRINKING FOUNTAIN MOP SINK WATER HEATER TANK TYPE TRAP PRIMER FLOOR DRAIN ATER HAMMER RRESTER FLOOR CLEANOUT COLD WATER 1/2" 1/2" ROUGH-IN SERVICES 1/2" WALL CLEANOUT HOT WATER 1/2" 3/4" WASTE 4" 2" 2" 2" 2" 2" VENT 2 " 1 1/2" 1 1/2' 1 1/2" 1 1/2" 1 1 /2" INDIRECT WASTE 3/4" GAS NTS 00NP011GOSCHD DESCRIPTION KOHLER "HIGHLINE PRESSURE LITE" MODEL NO. K-3519, 1.1 GPF, PRESSURE ASSISTED WHITE WATER CLOSET WITH ELONGATED VITREOUS CHINA BOWL (OR AMERICAN STANDARD "FLOWISE" MODEL NO. 2073.014, 1.28 GPF, ELONGATED TOILET), 17)6" HIGH, WHITE OPEN FRONT SEAT AND COVER #K-4710-T. FURNISH WITH BOLT CAPS AND CHROME SUPPLY STOP. (FOR PUBLIC AND NON-PUBLIC RESTROOMS). FLUSH LEVER SHALL BE LOCATED ON THE WIDE SIDE OF THE TOILET. PROVIDE #K-3519-RA FOR RIGHT SIDE FLUSHING HANDLE. KOHLER "KATHRYN" CONSOLE TABLE TOP MODEL NO. K-3029 WITH UNDER- COUNTER LAVATORY MODEL NO. K-2297-G, SQUARE LEGS MODEL NO. K-6861 AND "TABORET" FAUCET MODEL NO. K-8215-4 WITH POP-UP DRAIN. FURNISH WITH CHROME SUPPLY STOPS AND P-TRAP. INSULATE P-TRAP AND SUPPLY LINES WITH 1/2" ARMSTRONG "ARMAFLEX" PIPING INSULATION OR EQUIVALENT. (FOR PUBLIC RESTROOMS) KOHLER "DEXTER" URINAL MODEL NO. K-5016-ET (OR AMERICAN STANDARD #6541.132 "ALLBROOK", WHITE VITREOUS CHINA) FURNISH WITH SLOAN ROYAL 186-1 FLUSH VALVE. HALSEY TAYLOR SELF-CONTAINED, BARRIER-FREE, ELECTRIC, REFRIGERATED, WALL-MOUNTED, BI-LEVEL WATER COOLER #HTV8BL-Q. FURNISHED WITH PLUG-IN, 3-WIRE GROUNDING TYPE SERVICE CORD. STANDARD 120V, 60 HZ, 1PH. 120V RECEPTACLE REQUIRED, RATED AT 15 AMP MINIMUM, TO RECEIVE 3-WIRE PARALLEL BLADE GROUNDING TYPE MALE PLUG. PROVIDE CHROME SUPPLY STOP AND P-TRAP. SEE MANUFACTURER'S INSTRUCTIONS FOR PROPER INSTALLATION PER ADA. FIAT MOP MOLDED STONE SERVICE BASIN MODEL NO. MSB-2424 WITH VINYL BUMPERGUARD. FURNISH WITH AMERICAN STANDARD FAUCET MODEL NO. 8344.112 WITH INTEGRAL VACUUM BREAKER AND STOPS. PROVIDE 42" RUBBER HOSE WITH FAUCET. RHEEM WATER HEATER MODEL NO. EGSP-6, 6 GALLON, 208V-10-60, 3 KW AND 14.4 AMPS. PRECISION PLUMBING PRODUCTS TRAP PRIMER, MODEL NO. P-2, COPPER BODY, ADJUSTABLE WITH 1/2" COPPER TYPE " L " TO FLOOR DRAIN. ZURN FLOOR DRAIN MODEL NO, Z-415-6B, CAST IRON BODY, COMBINATION INVERTIBLE CLAMP AND ADJUSTABLE COLLAR, 2" BOTTOM OUTLET WITH 6" ROUND NICKEL BRONZE STRAINER. SIOUX CHIEF 650 SERIES WATER HAMMER ARRESTER OR EQUAL. ZURN ZN-1446-BP CLEANOUT TEE, DURA-COATED CAST IRON BODY, GAS AND WATER TIGHT BRONZE PLUG AND STAINLESS STEEL WALL ACCESS COVER WITH SECURING SCREW. ZURN FLOOR CLEANOUT MODEL NO. ZN-1400 WITH GAS-TIGHT AND WATER-TIGHT TAPERED THREADED PLUG AND ROUND POLISHED NICKEL BRONZE SCORIATED ADJUSTABLE TOP. PLUMBING FIXTURE SCHEDULE NTS OONP011EOSCHD REMARKS HANDICAP TYPE HANDICAP TYPE 1.0 GPF HANDICAP TYPE HANDICAP TYPE WITH DEEP SEAL P-TRAP D NEW WASTE OR SAN. SEWER PLUMBING CONSTRUCTION NOTES NTS 00NP011A0NOTE A NEW VENT - - EXISTING VENT NEW COLD WATER EXISTING COLD WATER NEW HOT WATER EXISTING HOT WATER -) SHUT-OFF VALVE ----4 - 4 - 1) FLOOR CLEAN-OUT - H I WALL CLEAN ® FLOOR DRAIN RISE 0 DROP : POINT OF CONNECTION LEGEND AND SYMBOLS NTS 00NP011D1LGND • -- DIVISION 22 SECTION 22000 - PLUMBING A. SCOPE OF WORK 1. THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL WORK FOR THE PLUMBING SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: A. B. C. D. E. F. G. 2. BEFORE STARTING WORK, THIS CONTRACTOR SHALL EXAMINE THE ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL PLANS AND SPECIFICATIONS TO SEQUENCE, COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE PLUMBING SYSTEM, MATERIALS, AND EQUIPMENT WITH OTHER CONTRACTORS TO AVOID INTERFERENCES AND CONFRONTATIONS. 3. RELOCATION OF EXISTING WATER, GAS, WASTE, VENT, OR DRAINAGE LINES TO FACILITATE STORE DESIGN CRITERIA MUST BE INCLUDED IN BID PROPOSAL B. EQUIPMENT AND INSTALLATION 1. REFER TO PLANS FOR SCHEDULES OF EQUIPMENT AND FIXTURES. AMERICAN STANDARD, KOHLER AND CRANE MAY BE CONSIDERED WITH APPROVAL FROM ESD&C PROJECT MANAGER. 2. SANITARY PIPING A. C. B. INSULATE ALL HORIZONTAL RUNS OF PIPING LOCATED IN CEILING SPACES, WHEN APPLICABLE. INSULATION TO BE AS SPECIFIED FOR WATER PIPING. CONDENSATE PIPING SHALL BE TYPE DRAWN COPPER TUBE WITH 95-5 TIN-ANTIMONY SOLDERED JOINTS AND WROUGHT COPPER FITTINGS WITH DIELECTRIC SEPARATION BETWEEN DISSIMILAR METALS. 3. POTABLE WATER PIPING SHALL BE AS FOLLOWS: A. BELOW GRADE: TYPE 'K', ANNEALED TYPE TEMPERED COPPER TUBE FOR PIPE SIZES 2 INCHES AND B. ALL OTHER: SULEL MI A UPp J EA T T s U . BE WITH WROUGHT COPPER FITTINGS AND 95-5 TIN- 4. PIPING OF DISSIMILAR METALS MUST BE DIELECTRICALLY SEPARATED. ANTIMONY SOLDER. 5. GENERALLY, SANITARY AND POTABLE WATER TAPS WILL BE PROVIDED BY THE LANDLORD. FIELD VERIFY EXACT CONNECTION POINTS PRIOR TO SUBMITTING BID. NOTIFY THE LSD&C PROJECT MANAGER, IF CONDITIONS ARE NOT AS SHOWN ON THE PLANS OR AS STATED IN THE SPECIFICATIONS. CONTRACTOR MUST VERIFY THE OPERABILITY OF ENTIRE SYSTEM PRIOR TO TIE-IN AS FOLLOWS: A. SNAKE SANITARY TO MALL MAIN AND REPORT ANY BLOCKAGE. B. TEST WATER PRESSURE TO INSURE MINIMUM PSI MATCHES MOST DEMANDED BY EQUIPMENT SUPPLIED. 6. INSULATE ALL HOT WATER, COLD WATER AND CONDENSATE PIPING WITH 1" THICK (K=0.23 0 751) PIPE INSULATION WITH AN ALL SERVICE JACKET TO MEET LOCAL CODES AND UL FLAME SPREAD AND SMOKE DEVELOPED RATINGS. 7. INSULATE THE TRAP, SANITARY AND SUPPLY PIPES UNDER LAVATORY WITH 1/2" ARMSTRONG "ARMAFLEX" PIPING INSULATION OR TRUEBRO MODEL 102W "HANDI LAV GUARD" INSULATION KIT. 8. INSTALL ALL NECESSARY PIPE HANGERS, SADDLES, AND CARRIERS TO PROPERLY SUPPORT ALL PIPING AND FIXTURES. HANGERS SHALL SUIT TYPE OF PIPING PROVIDED AND BE SPACED AT A MAXIMUM SPAN OF 5 FEET. PROVIDE SWAY AND SEISMIC BRACING WHERE REQUIRED BY CODES. 9. STERILIZE WATER SYSTEM IN ACCORDANCE WITH LOCAL CODES. 10. CLEANOUTS AND FLOOR DRAINS SHALL BE INSTALLED PER LOCAL CODES. WALL COVERS ARE TO BE STAINLESS STEEL AND FLOOR COVERS ARE TO BE BRASS, UNLESS OTHERWISE SPECIFIED. PROVIDE FLOOR COVERS WITH INSET AREA FOR CARPETED LOCATIONS. ALL CLEANOUT LOCATIONS SHALL BE APPROVED BY THE ESD&C PROJECT MANAGER. 11. ESCUTCHEONS SHALL BE CHROME PLATED, SIZE AS REQUIRED, AND PLACED AT ALL PIPE PENETRATIONS AT WALLS, FLOORS AND CEILINGS IN FINISHED AREAS. 12. LEAKAGE TESTS SHALL BE PER LOCAL CODES MINIMUM AS FOLLOWS: A. TEST WATER PIPING AT 100 PSIG FOR SIX HOURS. B. TEST DRAIN, WASTE, VENT PIPING BY A 10' WATER COLUMN FOR TWO HOURS 13. FLASHING SHALL BE SEALED WATERTIGHT AND PERFORMED IN ACCORDANCE TO THE LANDLORD'S CRITERIA. USE A LANDLORD APPROVED ROOFING CONTRACTOR, WHERE APPLICABLE. 14. PROVIDE WATER METER AND REMOTE READER PER LANDLORD'S CRITERIA OR LOCAL UTILITIES REQUIREMENTS, IF APPLICABLE. REFER TO PLANS TO DETERMINE IF WATER METER IS REQUIRED. END OF SECTION 15200 AD ADA AFF AP CD CFM CI CO CONT CONTR COTG CW DET DF DL DS DTR DWG COMPLETE SANITARY PIPING SYSTEMS OF WASTE, DRAINS, AND VENTS. COMPLETE COLD AND HOT WATER PIPING SYSTEMS, APPURTENANCES AND INSULATION. FIXTURES AND EQUIPMENT AS SCHEDULED. COMPLETE NATURAL GAS OR PROPANE PIPING SYSTEMS (AS APPLICABLE, REFER TO PLANS) CONDENSATE PIPING SYSTEMS (AS APPLICABLE, REFER TO PLANS). TESTS AND ADJUSTMENTS. SUBMIT A COMPLETE SET OF REPRODUCIBLE AS-BUILTS. WASTE, DRAIN AND VENT PIPING SHALL BE SERVICE WEIGHT CAST IRON SOIL PIPE. VENT PIPING ABOVE FLOOR 2" OR SMALLER MAY BE GALVANIZED STEEL ALTERNATE PIPING MATERIALS ARE ACCEPTABLE AS A SUBSTITUTION WHEN THEIR USE IS PERMITTED BY THE LANDLORD, LOCAL CODES AND BUILDING DEPARTMENT OFFICIALS AND DOES NOT AFFECT OTHER TRADES. SUBSTITUTIONS MUST BE LISTED AND QUALIFIED IN BID. NO PLASTIC PIPING ALLOWED. ACCESS DOOR AMERICAN DISABILITY ACT ABOVE FINISHED FLOOR ACCESS PANEL CEILING DIFFUSER OR CONDENSATE DRAIN CUBIC FEET PER MINUTE CAST IRON CLEANOUT CONTINUE CONTRACTOR CLEANOUT TO GRADE COLD WATER DETAIL DRINKING FOUNTAIN DOOR LOUVER DREAMSTEAMER DOWN THRU ROOF DRAWING (E) EXISTING EWC ELECTRIC WATER COOLER FCO FLOOR CLEANOUT FCU FAN COIL UNIT ED FLOOR DRAIN FPS FEET PER SECOND FS FLOOR SINK GAL GALLONS GC GENERAL CONTRACTOR GPM GALLONS PER MINUTE HB HD HP HW HOSE BIBB HEAD HORSEPOWER HOT WATER INV INVERT ABBREVIATIONS - PLUMBING LAV LB LF MECH MFR MTD MTR (N) N.C. N.I.C. N.O. N/A NTS PD PLBG POC PRV PSI (R) RD RPBP RPM LAVATORY POUND LINEAL FEET MECHANICAL MANUFACTURER MOUNTED MOTOR NEW NORMALLY CLOSED NOT IN CONTRACT NORMALLY OPEN NOT APPLICABLE NOT TO SCALE PUMP PRESSURE DROP PLUMBING POINT OF CONNECTION PRESSURE REDUCING VALVE POUNDS PER SQUARE INCH RELOCATE ROOF DRAIN REDUCED PRESSURE BACKFLOW PREVENTER REVOLUTION PER MINUTE SCH SCHEDULE SOV SHUT-OFF VALVE OR SCHEDULE OF VALVE UH UON UTR VTR VENT THRU ROOF WC WCO WG WH WHA WT UNIT HEATER UNLESS OTHERWISE NOTED UP THRU ROOF WATER CLOSET WALL CLEANOUT WATER GAUGE WATER HEATER WATER HAMMER ARRESTER WEIGHT ITEM PLUMBING FIXTURES & TRIM DRINKING FOUNTAIN AND ASSOCIATED ACCESSORIES. SEWER AND VENT PIPING TANK WATER HEATER DOMESTIC HOT AND COLD WATER PIPING CONDENSATE DRAIN PIPING SECOND COND. DRAIN PIPING GAS PIPING COND. DRAIN PUMP DREAMSTEAMER FLOOR DRAINS, CLEAN OUTS, WATER HAMMER ARRESTORS, ETC. DREAMSTEAMER DRAIN PIPING AS-BUILT DRAWINGS INSTANTANEOUS WATER HEATER FURNISHED BY LSD&C VENDOR LD DS LANDLORD CONTR. GC GC GC GC GC GC GC GC GC GC INSTALLED BY LANDLORD CONTR. GC GC GC GC GC GC GC GC GC GC OTHER GC N/A RE-USE EXISTING • REMARKS PLUMBING RESPONSIBILITY SCHEDULE PLUMBING RESPONSIBILITY SCHEDULE CD EXISTING WASTE OR SAN. SEWER CONDENSATE DRAIN 1. THESE PLANS MAY BE USED FOR CONSTRUCTION ONLY AFTER APPROVAL IS OBTAINED FROM THE BUILDING DEPARTMENT PLUMBING PLAN CHECK DIVISION AND THAT DIVISION'S STAMPED APPROVAL AND AUTHORIZED SIGNATURE APPEAR ON THE PLANS. 2. COORDINATE ALL WORK WITH ALL TRADES INCLUDED BUT NOT LIMITED TO ELECTRICAL, FIRE PROTECTION, MECHANICAL AND STRUCTURAL CONTRACTORS. INSTALL ALL WORK TO CLEAR NEW AND EXISTING ARCHITECTURAL AND STRUCTURAL MEMBERS. NO ITEM SUCH AS PIPE, DUCT, ETC. IS TO BE IN CONTACT WITH ANY EQUIPMENT. 3. REFER TO ARCHITECTURAL DRAWINGS FOR DEMOLITION WORK. 4, REFER TO ARCHITECTURAL DRAWINGS FOR EXACT FIXTURE LOCATION. 5. CONTRACTOR SHALL PROVIDE CUT SHEETS TO LSD&C FOR ALL EQUIPMENT AND DEVICES FURNISHED BY THE CONTRACTOR THAT DEVIATE FROM SPECIFIED ITEM FOR REVIEW AND APPROVAL PRIOR TO THE PURCHASE OF ANY SUCH EQUIPMENT OR DEVICES. 6. THE PLUMBING CONTRACTOR SHALL BE RESPONSIBLE TO FIELD VERIFY THE EXACT LOCATIONS, SIZES, INVERTS AND CONDITION OF EXISTING SANITARY WASTE PIPING BELOW SLAB, VENT PIPING ABOVE CEILING AND UP THROUGH ROOF AND DOMESTIC COLD WATER SUPPLY PIPING TO TENANT'S DEMISED PREMISES PRIOR TO SUBMITTING HIS BID. NO ADDITIONAL COMPENSATION WILL BE MADE FOR ANY EXTRAS DUE TO CONTRACTOR'S FAILURE TO VISIT THE JOB SITE AND/OR FAILURE TO PREDETERMINE ALL EXISTING CONDITIONS BEFORE SUBMITTING HIS BID. 7. ACCESS TO ALL COMPONENTS AND EQUIPMENT MUST BE PROVIDED TO MEET CODE AND SERVICE/MAINTENANCE EASE. 8. THE CONTRACTOR SHALL VERIFY WITH LOCAL CODES AS TO THE REQUIREMENT/INSTALLATION OF ANY "WATER SAVING" DEVICES TO THE PLUMBING FIXTURES. (EXAMPLE: TOILET, FAUCETS, ETC.). 9. PLUMBING SYSTEM SHALL BE PRESSURE TESTED AND STERILIZED PER LANDLORD'S CRITERIA AND LOCAL AUTHORITY. 10. UPON COMPLETION OF THE WORK, CONTRACTOR SHALL ENSURE THE PROPER WORKING ORDER OF THE SYSTEM(S) AND MAKE ANY ADJUSTMENTS AS REQUIRED. SHREMSHOCKA ENGINEERING, INC. 6130 S. .AD WESTERVILLE, OH 43081 614-545 T REQUIRED BY: DATE ISSUED: DESIGNED BY: DRAWN BY: CHECKED BY: INDICATES NO REVISION TO THIS SHEET 0 • z Z ; .9 LU LU 0 11: 1 '47 0 2 HNi • " 11 ! ! • LLi C OOL-LU =0 z !34 ° ce .T1 Y2 5U 0E1=L61 LU 0 c o .77 ° 55-N66-3LAiu REVISIONS: (NI 0 c0 U O) - 0 00 0 0 0- Do • w 0 IS- z 0 0(7) w ti c DATE 04/18/2008 PMK PMK TIP PLUMBING SPECIFICATIONS DRAWING NUMBER: PLUMBING GENERAL NOTES 1. UNLESS OTHERWISE SPECIFIED, CONTRACTOR SHALL PROVIDE ALL NECESSARY EQUIPMENT, MATERIAL, LABOR AND SUPERVISION NECESSARY TO COMPLETE THE PLUMBING WORK IN ACCORDANCE WITH THE SPECIFICATIONS AND STANDARDS. 2. FIELD VERIFY EXACT SIZE AND LOCATION OF EXISTING WASTE PIPING BELOW SLAB, VENT PIPING ABOVE CEILING AND UP THROUGH ROOF AND COLD WATER SUPPLY PIPING ABOVE CEILING PRIOR TO COMMENCEMENT OF ANY WORK. AFTER INSTALLATION AND FINAL CONNECTION OF NEW WASTE PIPING BELOW SLAB, BACK FILL AND PATCH IN ACCORDANCE WITH THE LANDLORD'S CRITERIA REGARDING SUCH WORK. 3. CONTRACTOR SHALL FURNISH AND INSTALL ALL OF THE NECESSARY PLUMBING FIXTURES (SEE PLUMBING RESPONSIBILITY SCHEDULE ON THIS SHEET) TO SERVE THE TENANT'S DEMISED PREMISES AND MAKE NECESSARY INSTALLATION OF DOMESTIC WATER AND SEWER PIPING FROM TENANT'S DEMISED PREMISE TO CONNECTION PROVIDED BY LANDLORD. 4. SANITARY VENTS SHALL BE ROUTED TO THE EXISTING LANDLORD'S POINT OF CONNECTION WITHIN THE TENANT'S DEMISED PREMISES OR TO A POINT APPROVED BY LOCAL AUTHORITY. THE CONTRACTOR SHALL PROVIDE A CAPPED TEE FOR POSSIBLE FUTURE CONNECTION (IF REQUIRED BY THE LANDLORD). CONTRACTOR SHALL COORDINATE ALL ROOF PENETRATIONS WITH THE LANDLORD'S ROOFING CONTRACTOR, AS REQUIRED. VENT THRU ROOF SHALL BE AT LEAST 15 FEET AWAY FROM A/C UNIT FRESH AIR INTAKE. 5. SEAL AROUND ALL PIPES PENETRATING FIRE SEPARATIONS WITH LISTED AND APPROVED FIRE SEAL MATERIAL. ONLY LISTED AND APPROVED SEALANTS AND METHODS FOR THE SPECIFIC USE WILL BE PERMITTED. 6. THE CONTRACTOR SHALL INSTALL ALL TOILET FIXTURES IN ACCORDANCE WITH ALL CODES AND AS REQUIRED BY LANDLORD'S CRITERIA. CONTROLS FOR FLUSH VALVES SHALL BE MOUNTED ON THE WIDE SIDE OF THE WATER CLOSET AND NO MORE THAN 44" A.F.F. 7. THE CONTRACTOR SHALL ENSURE THAT ALL SLAB PENETRATIONS WITHIN THE TENANT'S DEMISED PREMISES ARE PROPERLY SEALED AND REMAIN WATERTIGHT TO PREVENT ANY POSSIBLE DAMAGE TO OTHER TENANTS AND/OR TO THE BUILDING. FAILURE TO DO SO SHALL BE AT THE RISK AND SOLE EXPENSE OF THE CONTRACTOR. 8. ALL MATERIAL SHALL BE NEW AND OF COMMERCIAL GRADE, AND BEAR UNDERWRITER'S LABORATORIES AND UNION LABELS WHERE SUCH LABELING APPLIES. 9. PLUMBING CONTRACTOR TO FIELD VERIFY PROPER SLOPE OF EXISTING SEWER TO MAIN SEWER PRIOR TO ANY NEW PLUMBING INSTALLATION. 10. PLUMBING CONTRACTOR MUST VISIT THE JOBSITE TO BECOME FAMILIAR WITH MAJOR ITEMS SUCH AS STRUCTURAL ELEMENTS AND OTHER EXISTING JOB CONDITIONS THAT MAY AFFECT THE WORK. ADDITIONALLY, PLUMBING CONTRACTOR SHALL VERIFY EXACT LOCATIONS AND DIMENSIONS OF SUCH ITEMS AS WASTE, VENTS, WATER LINES, ETC. 11. PLUMBING CONTRACTOR TO FAMIUARIZE AND FOLLOW SPECIFICATIONS AND DETAILS CONTAINED IN DESIGN CRITERIA OF TENANT HANDBOOK. 12. PLUMBING CONTRACTOR TO CLEAR ALL EXISTING AND NEW DRAIN LINES AND FIXTURES, PRIOR TO TURNING OVER SPACE TO TENANT. 13. PLUMBING CONTRACTOR SHALL PROVIDE ACCESS TO VALVES, TRAP PRIMERS, ETC. INSTALLED BEHIND WALLS, FLOORS OR CEILINGS. 14. NO PLASTIC PIPING ALLOWED. FIEF Permit tioltiralLitl Plar review approval is subject to errors and omissions. Approva! of construction documents does not aulhorize the violation of any adopted code or ordinance. Receipt Of approved Field Copy and g.ftihs Is acknowledged: By Date: City of Tukwila EILIILOING DIVISION MOW; No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. SEPARATE FERMI REQUIRED FOR: of Mechanical 6 14 P E l l u e rn ct b ric in a g i BuiCL * FOR CODE COMPLIANCE PPROVED MAY - 8 T PU8 ...___ _ ClAy Of Tukwila . . BUILDING DIV.150:: Rua:7E crry OF TI IKVVILA APli 2 9 i11118 PERMIT CEA NTS 00NP011CONOTE B PLUMBING SPECIFICATION NTS 00NP011,10SPEC F ITEM I WC I LAV-1 I UR I I OF 1 I MS I TP FD I WHA I w co FCO FIXTURE WATER CLOSET TANK TYPE LAVATORY UNDERCOUNTER URINAL WALL MOUNTED DRINKING FOUNTAIN MOP SINK WATER HEATER TANK TYPE TRAP PRIMER FLOOR DRAIN ATER HAMMER RRESTER FLOOR CLEANOUT COLD WATER 1/2" 1/2" ROUGH-IN SERVICES 1/2" WALL CLEANOUT HOT WATER 1/2" 3/4" WASTE 4" 2" 2" 2" 2" 2" VENT 2 " 1 1/2" 1 1/2' 1 1/2" 1 1/2" 1 1 /2" INDIRECT WASTE 3/4" GAS NTS 00NP011GOSCHD DESCRIPTION KOHLER "HIGHLINE PRESSURE LITE" MODEL NO. K-3519, 1.1 GPF, PRESSURE ASSISTED WHITE WATER CLOSET WITH ELONGATED VITREOUS CHINA BOWL (OR AMERICAN STANDARD "FLOWISE" MODEL NO. 2073.014, 1.28 GPF, ELONGATED TOILET), 17)6" HIGH, WHITE OPEN FRONT SEAT AND COVER #K-4710-T. FURNISH WITH BOLT CAPS AND CHROME SUPPLY STOP. (FOR PUBLIC AND NON-PUBLIC RESTROOMS). FLUSH LEVER SHALL BE LOCATED ON THE WIDE SIDE OF THE TOILET. PROVIDE #K-3519-RA FOR RIGHT SIDE FLUSHING HANDLE. KOHLER "KATHRYN" CONSOLE TABLE TOP MODEL NO. K-3029 WITH UNDER- COUNTER LAVATORY MODEL NO. K-2297-G, SQUARE LEGS MODEL NO. K-6861 AND "TABORET" FAUCET MODEL NO. K-8215-4 WITH POP-UP DRAIN. FURNISH WITH CHROME SUPPLY STOPS AND P-TRAP. INSULATE P-TRAP AND SUPPLY LINES WITH 1/2" ARMSTRONG "ARMAFLEX" PIPING INSULATION OR EQUIVALENT. (FOR PUBLIC RESTROOMS) KOHLER "DEXTER" URINAL MODEL NO. K-5016-ET (OR AMERICAN STANDARD #6541.132 "ALLBROOK", WHITE VITREOUS CHINA) FURNISH WITH SLOAN ROYAL 186-1 FLUSH VALVE. HALSEY TAYLOR SELF-CONTAINED, BARRIER-FREE, ELECTRIC, REFRIGERATED, WALL-MOUNTED, BI-LEVEL WATER COOLER #HTV8BL-Q. FURNISHED WITH PLUG-IN, 3-WIRE GROUNDING TYPE SERVICE CORD. STANDARD 120V, 60 HZ, 1PH. 120V RECEPTACLE REQUIRED, RATED AT 15 AMP MINIMUM, TO RECEIVE 3-WIRE PARALLEL BLADE GROUNDING TYPE MALE PLUG. PROVIDE CHROME SUPPLY STOP AND P-TRAP. SEE MANUFACTURER'S INSTRUCTIONS FOR PROPER INSTALLATION PER ADA. FIAT MOP MOLDED STONE SERVICE BASIN MODEL NO. MSB-2424 WITH VINYL BUMPERGUARD. FURNISH WITH AMERICAN STANDARD FAUCET MODEL NO. 8344.112 WITH INTEGRAL VACUUM BREAKER AND STOPS. PROVIDE 42" RUBBER HOSE WITH FAUCET. RHEEM WATER HEATER MODEL NO. EGSP-6, 6 GALLON, 208V-10-60, 3 KW AND 14.4 AMPS. PRECISION PLUMBING PRODUCTS TRAP PRIMER, MODEL NO. P-2, COPPER BODY, ADJUSTABLE WITH 1/2" COPPER TYPE " L " TO FLOOR DRAIN. ZURN FLOOR DRAIN MODEL NO, Z-415-6B, CAST IRON BODY, COMBINATION INVERTIBLE CLAMP AND ADJUSTABLE COLLAR, 2" BOTTOM OUTLET WITH 6" ROUND NICKEL BRONZE STRAINER. SIOUX CHIEF 650 SERIES WATER HAMMER ARRESTER OR EQUAL. ZURN ZN-1446-BP CLEANOUT TEE, DURA-COATED CAST IRON BODY, GAS AND WATER TIGHT BRONZE PLUG AND STAINLESS STEEL WALL ACCESS COVER WITH SECURING SCREW. ZURN FLOOR CLEANOUT MODEL NO. ZN-1400 WITH GAS-TIGHT AND WATER-TIGHT TAPERED THREADED PLUG AND ROUND POLISHED NICKEL BRONZE SCORIATED ADJUSTABLE TOP. PLUMBING FIXTURE SCHEDULE NTS OONP011EOSCHD REMARKS HANDICAP TYPE HANDICAP TYPE 1.0 GPF HANDICAP TYPE HANDICAP TYPE WITH DEEP SEAL P-TRAP D NEW WASTE OR SAN. SEWER PLUMBING CONSTRUCTION NOTES NTS 00NP011A0NOTE A SHREMSHOCK >_ 6130 S. WESTERVt 614- 545 =' * INDICATES NO REVISION TO THIS SHEET REVISIONS: PLUMBING PLAN AND NOTES DRAWING NUMBER: W !!:!7! Z U a s w r w3- O W rvi w ZVt � U OV S te.? Z ° w N © � g z O dw V' a w oz Lu ii o�o� e r w o - z z v )/ 0w $4ao b�ura �aa� ® � L a O U a m W 2 © LL[ L p N W w w \ Vl - U O� Vm)oin d a 0 U j vw a z 00 U U h a Z p 2 Z 4 d O w 4 O OZ i2 C7 z O � ~U p w 6' 1a a Z b Z V , U w w O m H • i - 3 C] E L 0 p r © := L i a 4 O w a m m a 4 cZ5 q G Z b lw. ° 0 2 ° H ra U � q xx 2 � - � C : O � - VI W~ r N C) 2 > - 2 4 0 W U � . .:, RU U la.Y� O VI L y W 0 a' 4 W d X Z L' w p T U p V7 N E m " O © Q V) zJ b ( 'j �w (? U . d 9 O W R'w W K O Z z a z N Vi b U 0 U = E 4„ a „ N U 71m,- w 2 C Z � rwz �j� x r 0 Z b U) ' - w w W t- Cti w VW)C W v d xF w K UJi"sW ZZ "17-4,!0 W4 w! OOH i )n�6° 2w U : O? Z • w 2 j Z O Z Z i C O Z Z ���oa� two °pa z0 ° 'Q�v Jg n? : ;aH i v)a d �Ue O °'4p U 5r. Z OF W� WpW d U WHO �''"A' ..,..,:; W2._d W'=" ) _ O C V) .:=0..... 2 0 U o U W L p m . W Y g r W 2 1,T- Ua� W 4 r a24 a 8 Ut- _m L,, vl=, N 0 QO cn 00 DO CL. C O REQUIRED BY: DATE DATE ISSUED: 04/18/2008 DESIGNED BY: PMK DRAWN BY: PMK CHECKED BY: JTP PLUMBING PLAN P03.1 DOMESTIC WATER PIPING DIAGRAM DREAM STEAMER (BY OTHERS). P03.1 3/4 1 1/2" I 1 1/2" ,J 1 /21' 3/4" WASTE & VENT PIPING DIAGRAM P03.1 1/2" FROM 01 CONNECT NEW SANITARY LINE INTO THE LANDLORD'S EXISTING SANITARY SERVICE. FIELD VERIFY EXACT LOCATION OF LANDLORD'S MAIN PRIOR TO BIDDING. INSTALL CLEAN OUT AT CONNECTION TO LANDLORD'S MAIN. REFER TO STACK DIAGRAM AND PLUMBING SPECIFICATIONS FOR FURTHER INFORMATION. FIELD VERIFY EXACT LOCATION OF SANITARY CONNECTION PRIOR TO BID. VTR: VENT TO BE EXTENDED THROUGH ROOF. OFFSET 2' -0 AND TERMINATE WITH 3" VENT THROUGH ROOF. CONTRACTOR SHALL MAINTAIN 10' -O" MINIMUM CLEARANCE FROM ALL INTAKE HOODS. REFER TO STACK DIAGRAM AND PLUMBING SPECIFICATIONS FOR FURTHER INFORMATION. 0 CONNECT NEW COLD WATER LINE INTO THE EXISTING COLD WATER TAP. REFER TO RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR FURTHER INFORMATION. FIELD VERIFY EXACT LOCATION OF LANDLORD'S DOMESTIC COLD WATER PIPE PRIOR TO BID. P03.1 0 PROVIDE WATER REQUIREMENTS. METER WITH REMOTE READER PER LANDLORD'S AND WATER COMPANY REQUIREMENTS. FIELD VERIFY EXACT LOCATION AND 0 WH-2: PROVIDE NEW TANK TYPE WATER HEATER. MOUNT ON SHELF ABOVE MS. ROUTE DRAIN LINE TO MOP SINK. SEE RISER DIAGRAM, PLUMBING FIXTURE SCHEDULE AND DETAIL B ON SHEET P03.1 FOR REQUIREMENTS. (i) WHA: FURNISH AND INSTALL WATER HAMMER ARRESTERS IN THE DOMESTIC COLD AND HOT WATER PIPING AS SHOWN ON THE WATER RISER DIAGRAM. WATER HAMMER ARRESTERS TO BE LOCATED IN AN ACCESSIBLE LOCATION. 0 INSTALL 1/2" COLD WATER PIPE FROM TRAP PRIMER DOWN IN WALL UNDER FLOOR TO FLOOR DRAIN. TRAP PRIMER TO BE LOCATED IN AN ACCESSIBLE LOCATION. - ALL PLUMBING FIXTURES SHALL BE INSTALLED WITH STOP VALVES TO ISOLATE EACH FIXTURE. ROUTE THE CONDENSATE DRAIN AND SECONDARY DRAIN FROM AIR HANDLING UNIT TO LAV -2. MINIMUM DRAIN SIZE TO BE 1" OR AS SPECIFIED ON PLAN. CONDENSATE DRAIN SIZE TO BE TRAPPED WITH A TRAP DEPTH OF 1.5 X UNITS TOTAL STATIC PRESSURE. PIPING SHALL BE PVC. � PLUMBING CONTRACTOR SHALL INSTALL A 3/8" BALL VALVE ON WALL FOR DREAMSTEAMER. 0 1" PRIMARY CONDENSATE DRAIN FROM EQUIPMENT TO DISCHARGE AT LAVATORY. REFER TO DETAIL K ON SHEET P03.1. PLUMBING CODED NOTES VERIFY ALL FIELD CONDITIONS PRIOR TO BID MAY - 8 2000 City Of TUkW!la BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 2 9 2008 PERMIT CENTER CEILING LAVATORY SLOPE FUNNEL SINGLE OR MULTIPLE DISCHARGE WATER LINE FROM CONDENSATE DRAIN OF FC /AHU /WATER SOURCE HEATPUMP TO TAILPIECE OF LAVATORY DREAMSTEAMER DETAIL FLOOR SLAB MIN. 4" NON- COMBUSTIBLE FIRE STOPPING CAULK WITH FLEXIBLE FILLER SLEEVE NOTE: ALL FLOOR PENETRATIONS MUST BE SLEEVED AND LIQUID TIGHT. PIPE FLOOR PENETRATION DETAIL WALL CLEANOUT WALL ACCESS COVER RATED WALL (E) OR (N) PIPE D FIRE BARRIE AULK OR ILL 1" FIBERGLASS INSULATION THRU WALL ONLY UNINSULATED - UL SYSTEM WL 10 3M B CP25WB+ COMPLETEL SPACE BETWE WALL AND L 5/8" BE OUTSID QUAL, NULAR IPE AND MIN. OTH N ULATED - UL Y TEM WL 5039 THRU FIRE WALL PENETRATION DETAIL I VIII 1111111 1111 AROUND FACES OF WA NOTE: INSTALLATION TO FOLLOW UL SYSTEM WL 1001 OR WL 5 AND BE A UL TESTED ASSEMBLY. NTS OODPO31COPFWP CONDENSATE DRAIN DETAIL CONDENSATE DRAIN TO SLOPE DOWN TO SANITARY RECEPTOR WITH APPROVED AIR GAP VENTED SLOPE 12" MIN. PERFORATED CAP UNION SLOPE TRAP FOR WATER SEAL CONDENSATE DRAIN DETAIL NTS OODP031KOCOND NTS OODPO31J2COND K J FLOOR DRAIN ‘I N Pr 4110 . HANGERS (MUST BE WITHIN 6" OF DROP) — �"" 1/2" TYPE "L" WATER SUPPLY, CLAMP TO WALL AT TOP, MIDPOINT AND BOTTOM. (DO NOT RUN PIPE INSIDE WALL.) -- NON -SALES 88" NOTE: POWER AND WATER TO BE LOCATED WHERE MOST ACCESSIBLE, BASED ON DETAIL. DREAM - STEAMER C.W. MAIN JOIST /BEAM 1/2" TYPE "L" SUPPLY ._ CEILING WALL 1/2" TYPE "L" DRAIN DOWN TO FLOOR DRAIN. TERMINATE 1" ABOVE FLOOR DRAIN WATTS SERIES "9DM3" DOUBLE CHECK BACKFLOW PREVENTER WITH VENT PROVIDE A 3/8" BALL VALVE ON WALL INSTALL 3/8" X 72" • FLEXIBLE BRAIDED 2'- TUBING FURNISHED WITH DREAMSTEAMER FINISHED FLOOR SECTION VIEW rr) CNI C) M DREAMSTEAMER RECEPTACLE (SEE 1/2" C.W. SUPPLY ELECTRICAL DWGS.) FACTORY POWER WALL CORD WITH PLUG 48" T 2' -O" MAINTENANCE CLEARANCE 3/8" BRAIDED FLEXIBLE TUBING FLOOR DRAIN PLAN VIEW WALL CLEANOUT DETAIL FLOOR CLEANOUT DETAIL NTS OODP031HODRST NTS OODP031GOPFPD NTS OODP031FOWCOD CLEANOUT PLUG FINISHED FLOOR CONCRETE SLAB STRUCTURE AT UPPER LEVEL SEALANT TO TENANT'S SANITARY SEWER / \/, 4. COVER ADJUSTABLE HOUSING 4 GRADE AT LOWER LEVEL NTS 00DP031EOFCOD H G F E TURN DOWN INTO STACK •• ROOFING MATERIALS (FLASHING, ETC.) PER LANDLORD REQUIREMENTS INCREASER WHEN REQUIRED MIN. 12" MIN. 12" ROOFING MATERIAL ROOF CONSTRUCTION SLEEVE ROOF CONSTRUCTION AS REQUIRED VENT STACK VENT THRU ROOF DETAIL WATER HEATER DETAIL FLOOR DRAIN DETAIL NTS OODPO31DOVTRD D VACUUM BREAKER BY P.C. GATE /BALL VALVE BY P.C. (TYP.) THERMAL EXPANSION TANK, IF REQUIRED BY CODE 3/4" T & P RELIEF VALVE BY P.C. RUN 3/4" COPPER PIPE TO MOP SINK DRAIN VALVE BY P.C. PLATFORM BY GENERAL CONTRACTOR 3 / 4 " CW 6 " NOTE: NW 3/4"-/ 1" SECONDARY DRAIN INSULATE ALL PIPING IN ACCORDANCE WITH SPECIFICATIONS. P . n DRAINS TO MOP SINK UNION BY P.C. (TYP.) WATER HEATER SEE PLUMBING FIXTURE SCHEDULE FOR ADDITIONAL INFO. 2" WIDE, 20 GA. SHEET METAL BAND AT UPPER THIRD AND LOWER THIRD, SECURE TO WALL FOR SEISMIC BRACING WHERE REQUIRED BY CODE. (BY P.C.) GALV. DRIP PAN BY P.C. REVIEWED FOR CODE COMPLIANCE PP O l9/ I D MAY - 8 2008 City Of Tukwila BUZL.DJ 'ISION NTS OODP031SOWHTR FINISHED FLOOR SEALANT STRUCTURE AT UPPER LEVEL CONCRETE SLAB OR FINISHED FLOOR GRADE AT LOWER LEVEL r MIN. 4" DEEP SEAL TO TENANT'S SANITARY SEWER RECEIVE CITY OF TUK LA APR 2 9 2008 PERMIT CENTER NTS OOP031AOFLDN B A SHREMSHOCK 6130 S. WESTERVI 614 -545 op 0 0 0 0 GINEERING, INC. y, RO 0 L1 W64 =¢ z w w a s o -wv1 r' y : � z = = L.F • —'-&-(5/!''m d6 . m • W d C ". V 1� C] W V U O O N O V U OO = 4 = = O U C Z 4 • ~ • U Z = p - CJ W 1 -� _ a= o Z !- © 4 = = 00 E2 O N � � U H V U 1 O Y O O 4 • Q } U F VI J C' 1=j1 0 p N E a U Ucewz U _®_ O F- N • 4 F - . g — C] X W � W i U V) W H S= - 2 H U = = _ 3Q= U V) U d ,, „ O -- 7- V S U • O U— U _ 4 _ k w N I- � w w C N4 Lid W I— a co CD L c)0' 0 >CD CD Imo At CO 0 2 co CO C 00 w � � "- 0 ELI cc Ili 0-0 O /� �z )IX F 0w a- (I') g wZ0 W ° 0 65 a U I Ott w U Li v) W"dl F- t!) 0 w REQUIRED (3Y: • INDICATES NO REVISION TO THIS SHEET REVISIONS: DATE DATE ISSUED: 04/18/2008 DESIGNED BY: PMK DRAWN BY: PMK CHECKED BY: JTP PLUMBING DETAILS DRAWING NUMBER: 1