Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG08-141 - WESTFIELD SOUTHCENTER MALL - OAKLEY
OAKLEY 556 SOUTHCENTER MALL PGO8-141 Parcel No.: 6364200010 Address: Suite No: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tulcwila.wa.us PLUMBING /GAS PIPING PERMIT 556 SOUTHCENTER MALL TUKW Permit Number: Issue Date: Permit Expires On: PG08 -141 06/10/2008 12/07/2008 Tenant: Name: OAKLEY Address: 556 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: ELIZABETH VALERIO Address: 5858 WILSHIRE BL, #203 , LOS ANGELES CA Contractor: Name: LAKEVIEW CONSTRUCTION INC Address: PO BOX 308 , PLEASANT PRAIRIE, WI Contractor License No: LAKEVCI072KC Phone: Phone: 323 - 954 -8996 Phone: 414 657 -4222 Expiration Date: 01/13/2009 DESCRIPTION OF WORK: PROVIDE SINK FOR TENANT SPACE. Value of Plumbing /Gas Piping: Fees Collected: $1,500.00 $115.00 Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 FIXTURE TYPE AND QUANTITY Plumbing (cont.) 0 Building sewer and each trailer park sewer 0 0 Rain water system - per drain (inside bldg) 0 0 Water heater and /or vent 0 0 Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 0 grease interceptors 0 0 Repair or alteration of water piping and/or water 0 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 0 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 0 0 Medical gas piping (6 +) inlets /outlets 0 1 Gas Piping 0 Gas piping outlets (0 -5) 0 0 Gas piping outlets (6 +) 0 * *continued on next page ** doc: UPC -10/06 PG08 -141 Printed: 06 -10 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: PG08 -141 Issue Date: 06/10/2008 Permit Expires On: 12/07/2008 Permit Center Authorized Signature: Date: /HD O7 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of wor I jap'authorized to sign and obtain this plumbing /gas piping permit. Date: p -/O --(k1) Signature: Print Nam This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -10/06 PG08 -141 Printed: 06 -10 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: OAKLEY • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 556 SOUTHCENTER MALL TUKW PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: PG08 -141 ISSUED 04/30/2008 06/10/2008 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. * *continued on next page ** doc: Cond -10/06 PG08 -141 Printed: 06-10 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print N c)L,, I4,f 1 Ac.le-c__ Date: 67/0-0/ ordinances governing or local laws regulating doc: Cond -10/06 PG08 -141 Printed: 06 -10 -2008 CITY OF TUKWILP Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hup: %u tivtic. ci. !I(L \� -ilu. �cu. tcs ID Building Permit No. p Mechanical Permit No. ,.04)° 12-6 Plumbing/Gas Permit No. P( e- !t-' Public Works Permit No. Project No. Cit5-1)D (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: Tenant Name: ``�� Property Owners Name: ',,(4b S4 e.k.12 �,✓N Mailing Address: 1 1 AO( ()V VThit i\(i 556 Sato cl,-rok- Cak I King Co Assessor's Tax No.: Suite Number: 636 4ao -.6416 Floor: /' New Tenant: � Yes ❑..No City ) bf. State Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: l / iP 6 Vl / I 1)v ) Day TTelephone: 62-3-- 9Cj�`-t 6 Y /0/ Mailing Address: 1j Gt-� i l 54 ./ i/ ` V6 L. l e4 ((-0�' City State / /, /� Zip E -Mail Addicss: e v(i 1 ev1D )�%&/flfibl -Oiu 1 . eat, Fax Number: 7 3-- 7 sL/— $ r( S GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: 1-6D f jD Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: City Day Telephone: Fax Number: Expiration Date: State Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: Contact Person: E -Mail Address: VG /-eXiD A lM s� 6),/s4. e- 61vJ 2O3 cS ,, / p��, City State Zip 1 ZZ �f_i1 V� i ! Da ��T��ellephone: "�� —may x /6/ FaiV- ribber: �� ?j [ V g KS 'i 0)k ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: Contact Person: E -Mail Address: *100 (e_ C . %,SWt o \Applications\Forms- Applications On Line\3 -2006 - Permit Application doc Revised 9 -2006 bh cit Day Telephone: "1 n ' /� -7 (7 72 - t��y Fax Number: a l t `/ 7� Z -/y l Page 1 of 6 State Zip BUILDING PERMIT INFORI\'ION — 206 -431 -3670 Valuation of Project (contractor's bid price): $ gOb f� Existing Building Valuation: $ 144— %4- Scope of Wo k (please provide detailed information): / Aitir Will there be new rack storage? Yes ❑.. No if yes, a separate permit and p1 submittal will be required. Provide AII:Building Areas in .Square Footage Belo PLANNING DIVISION: Single family building footprint`(ar of the foundation of all structures, plus any decks over 18 iihes and overhangs greater than 18 inches) *For an Accessory dwelling, pro de the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentat n that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls P ovided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: XSprinklers Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flamma le, combustible or hazardous materials in the building? ❑ Yes No 1f "yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Sa ety ata Sheets. SEPTIC SYSTEM ❑ On -site pti System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. o'Applications'Forms -Appl ica Lions On Line,3 -2006 - Permit Application doc Revised 9- 2006 bh Page 2 of 6 xisting InteriorRernodel Addition to Existing Structure .. " New Type of •Construction,per .. • IBC - ,• - Type.of ;; . Occupancy per 1BC ls'Floor I o P •' p- ¶r _. M 2nd Floor F 3`g Floor Floors thru Basement \ f ., Accessory Structure* Attached Garage Detached Garage Attached Carport :' Detached Carport Covered Deck i• Uncovered Deck PLANNING DIVISION: Single family building footprint`(ar of the foundation of all structures, plus any decks over 18 iihes and overhangs greater than 18 inches) *For an Accessory dwelling, pro de the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentat n that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls P ovided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: XSprinklers Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flamma le, combustible or hazardous materials in the building? ❑ Yes No 1f "yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Sa ety ata Sheets. SEPTIC SYSTEM ❑ On -site pti System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. o'Applications'Forms -Appl ica Lions On Line,3 -2006 - Permit Application doc Revised 9- 2006 bh Page 2 of 6 PLUMBING AND GAS PIPING RMIT INFORMATION - 206 - 431- 70 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: Expiration Date: City Day Telephone: Fax Number: State Zip Valuation of Plumbing work (contractor's bid price): $ i , Sdd 6 Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): ire l t-t J-2j r'e � / � - Building Use (per Int'I Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and /or gas piping outlets being installed and the quantity below: Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath /shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain Sinks Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and /or vent Additional medical gas inlets /outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and /or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets /outlets for specific gas Q.Wpplications \Forms - Applications On Line\3 -2006 - Permit Application doc Revised 9 -2006 bh Page 5 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN Signature: O : AUTHORIZED AGENT: i �41 Print Name: Mailing Address: Day Telephone: 1.—� /iry Date: / Li/0 State Zip Date Application Accepted; 4 -50-05 Date Application Expires: /� -67 - -d StaffMitials: Q'•Applicationri.Forms- Applications On Line'J -2006 - Permit Application doc Revised 9 -2006 bh Page 6 of 6 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: PG08 -141 Address: 556 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 04/30/2008 Applicant: OAKLEY Issue Date: Receipt No.: R08 -02044 Payment Amount: $92.00 Initials: BLH Payment Date: 06/10/2008 09:26 AM User ID: ADMIN Balance: $0.00 Payee: LAKEVIEW CONSTRUCTION TRANSACTION LIST: Type Method Descriptio Amount Payment Check 224234 92.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLUMBING - NONRES 000.322.103.00.0 92.00 Total: $92.00 3494 06 /10 9711 TOTAL 92.00 doc: Receiot -06 Printed: 06 -10 -2008 O City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 SET RECEIPT Steven M. Mullet, Mayor Steve Lancaster, Director RECEIPT NO: R08 -01417 Initials: BLH Payment Date: 04/30/2008 User ID: ADMIN Total Payment: 1,461.73 Payee: EXPRESS PERMITS SET ID: S000001018 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount D08 -242 1,293.50 EL08 -495 100.00 M08 -125 45.23 PGO8 -141 23.00 TOTAL: 1,293.50 TRANSACTION LIST: Type Method Description Amount Payment Check 11553 1,461.73 TOTAL: 1,461.73 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES 000.345.832.00.0 100.00 000/345.830 1,361.73 TOTAL: 1,461.73 1811 04/30 9711 TOTAL 1461°73 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION F- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 PC --/9/ Project: % Type of Inspection: Address: 5-6-6 /Ad/ Date Called: Special Instructions: Date Wanted: �� /�� a.m. PAL Requester: Phone No: Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: c_n4/1e 71e. (Date: 7/,f,42' LI $60.00 INSPECTION FEE REQUIRED. Prior to inspection, fee must be paid 300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit p6ov-pw PERMIT NO. ti CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: 4.414. Type of Inspection: Address: .� S6 MAW Date Called: Special Instructions: Date Wanted: ` 7/ /g14 g P.m. Requester: Phone No: 3% le03 ,2tlo Approved per applicable codes. Corrections required prior to approval. COMMENTS: rfovieh bAddig,) ,par4 744.574 Inspector: Date: ? //p / 9 $60.O9EINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPE ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 Project/1/444k e key Type of InspectigtO: r/��,�� r9 / 4 Address: .57C4 /041/ Date Called: ...---,7- Special Instructions: Date Wanted / J !/ /O � (a.m. p.m. Requester: Phone No: ?5-3 S /2'2 i' Approved per applicable codes. El Corrections required prior to approval. COMMENTS: PO r e : ?roil/de Now AJe*G7ilrer, /nh 4 & - # 4 . 4 6v` /h -u e - dw 5 ..O,• b,„, i 4/00 "%- i/e,01 -e'.i Inspector: $60.00 ° ' NSPECTION FEE REQUIRED. Prior to inspection, fee must be paid 00 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Name: ?k6-1141 5237 P.L.E. BACKFLOW TESTING Phone: 253 297 -4387 www.backflowtester.com Fax: 253 864 -0107 P.O. Box 9199 * Covington, Washington 98042 Backflow Test Report PLE A ILlf_Q Passed "L Failed Service Address: SS-to 5.-,b,5 -1-L M A I ( - ,,) (14 L,.. q . Backflow Location: l AL1 room a LooF s 0 i►.f�c Cross Connection Control for: �0 mg v -(e. Type Assembly: D - 11/4 Manufacturer: Ld tS Model:067 " Size: 2/41( Serial No:ft- i 25413 Initial Test Result Test After Repairs RPBA Line Pressure- No. 1 Check Valve. psid Relief Valve Opened. psid Buffer Amount. psid No. 1 Check: Closed Tight Leaked No. 2 Check: Closed Tight Leaked Minimum Air Gap: Yes No Passed Test Yes No DCVA Line Pressure: No. 1 Check: No. 2 Check: Passed Test Closed Tight a.. 1 Leaked Closed Tight .2 < Ca Leaked es No PVB /SPVB Line Pressure: Air Inlet: Opened Check Valve: Passed Test Yes psid Failed to open psid Leaked No AIR GAP: Minimum Separation Yes No Pipe Gap Test Equipment: Make- AA49:6 Model:? 9Q Serial#: ©L 3 fS&,03 Accuracy Verification Date- ),a-,18-1)-7 Repairs/Remarks: RPBA Line Pressure- No. 1 Check Valve. psid Relief Valve Opened. psid Buffer Amount. psid No. 1 Check: Closed Tight Leaked No. 2 Check: Closed Tight Leaked Minimum Air Gap: Yes No Passed Test Yes No DCVA Line Pressure: No. 1 Check: Closed Tight No. 2 Check: Closed Tight Passed Test Yes No Leaked Leaked PVB /SPVB Line Pressure: Air Inlet: Opened psid Failed to open Check Valve: psid Leaked Passed Test Yes No ASSEMBLY STATUS: New X Existing PROPERLY INSTALLED: Yes No I CERTIFY THIS REP RT O Michael J. G. ti Signature: Print Name: E RUE PRINT Phone: Cell 253 297 -438 Initial Test: Cert# ate: 7-1 — 8 B1423 Repairs: Date Repaired Test: Date. Cert. # UBI 601 040 690 • PERMIT COORD COPY� PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG08 -141 PROJECT NAME: OAKLEY SITE ADDRESS: 556 SOUTHCENTER MALL DATE: 04 -30 -08 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter #_ Revision # After Permit Issued DEPARTMENTS: ,v f3'� Bui g Division Pub is Wo ks Fire Prevention Structural Planning Division n Permit Coordinator ETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 05 -01 -08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUJING: Please Route 11 Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DUE DATE: 05 -29 -08 DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Look Up a Contractor, Electri. or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. License Information License LAKEVCI072KC Licensee Name LAKEVIEW CONSTRUCTION INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601447862 Ind. Ins. Account Id 86508200 Business Type CORPORATION Address 1 10505 CORPORATE DR, #200 Address 2 City PLEASANT PRAIRIE County OUT OF STATE State WI Zip 53158 Phone 4146574222 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 5/3/1993 Expiration Date 1/13/2009 Suspend Date Separation Date Parent Company Previous License STATECC113B3 Next License Associated License Business Owner Information Name Role Effective Date Expiration Date SUNDAY, EUGENE R PRES 01/01/1980 MOON, KENT A VP 01/01/1980 SUNDAY, EUGENE R SECRETARY 01/01/1980 MOON, KENT A TREASURER 01/01/1980 a Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= LAKEVCI072KC 06/10/2008 MARK DESCRIPTION W V HW CW . OTHER REMARKS EWH WATER - 3/4" " . 3/4 - RHEEM EGSP6, 6 GALLON ELECTRIC WATER HEATER, 208V/1PH, 2000W MOUNTED ON WALL BRACKETS ABOVE MOP SINK MS MOP SINK 3" 1 -1/2" 1/2" 1/2" - ZURN MODEL Z1996 -24 COMPOSITE MOLDED 24X24 MOP SINK, COMPLETE WITH STAINLESS STEEL DOME STRAINER/LINT BASKET. SINGLE FAUCET AND MOP HANGER, HOSE, AND HOSE BRACKET 1.00 - GENERAL 1.01 DESCRIPTION Furnish all labor, materials, equipment and services required for and /or reasonably incidental to the completion of the following work: A. Sanitary waste and vent piping system including connections to building sewer as shown. B. Domestic hot and cold water systems including water heater, and related accessories and controls. C. Connection to building water as shown. D. Plumbing fixtures, trim and accessories including installation and support. E. Flashing and sealing of roof and exterior wall penetrations for water tightness. F. Caulking and sealing of floor and wall penetrations and formed shaft penetrations. G. Backing for securing fixtures, trim and piping. H. Access doors where shown or required by code. I. Hangers, supports, and guides. J. Cleanup of debris and final cleanup of drains, fixtures and equipment. K. License, permits and associated fees. L. Cutting, drilling and patching for all surfaces in relation to plumbing work. 1.02 RELATED WORK INCLUDED UNDER OTHER SECTIONS A. Mechanical Work -15000 B. Electrical work -16000 1.03 EXAMINATION OF SITE A. Visit site before submitting bid and check location of all existing conditions which will affect this work, verify dimensions and locations shown on drawings and cover all costs. Contractor shall assume reasonable variations or minor omissions and shall complete proposed work without additional cost. Failure to visit site will not lessen responsibility or entitle additional compensation for work not included in proposal. 1.04 DRAWINGS The accompanying drawings shall be considered part of these specifications. Work and materials shown on the drawings and not mentioned in the specifications and vice versa shall be executed as if specifically mentioned or shown in both. The drawings shall be considered as schematic in nature and minor modifications of the work to comply with the structure as found shall be made. 1.05 RULES AND REGULATIONS A. All work and material shall be in full accordance with the latest Plumbing Code and other applicable State and local rules and regulations. Nothing in these drawings or specifications shall be construed to permit work not conforming to these codes. B. Furnish without any extra charge any additional material and labor when required to comply with these laws, ordinances and codes regardless of whether shown or mentioned in these specifications of drawings. 1.06 MATERIAL SUBMITTALS A. Submit for review to Owner a complete and all- inclusive list of equipment and materials proposed fur use (4 copies), accompanied by manufacturer's data sheets giving sizes, capacities, etc. Data shall be forwarded in a single package written 15 days after award of contract. 1.07 AS -BUILT DRAWINGS A set of plumbing plans will be furnished to the Contractor on which he shall indicate the installation "as- built" as the work progresses. Upon completion of the work, a set or reproducible drawings shall be obtained from Owner at cost, and all changes as noted on the record set of prints shall be incorporated thereon. This set of reproducibles, along with one set of blueprints, shall be delivered to Owner upon completion and before final acceptance of the project. 1.08 GUARANTEE The Contractor shall leave the entire installation in complete working order free from any defective material, workmanship or finish. He shall guarantee to repair or replace, without charge, defects due to faulty workmanship or material for a period of one year from the date of filing of the Notice of Completion. 2.00 MATERIALS 2.03 VALVES A..Gate Valves: Nibco T -133 or equal, 2" and smaller. B. Check Valves: Nibco T -480 -Y or equal, 2" and smaller. 1.09 OPERATION MANUALS AND OWNER INSTRUCTIONS A. Provide complete operation and maintenance manuals covering all plumbing systems and equipment that have been installed. Three (3) copies of the manual shall be bound in hardback binders. B. Provide instructions to owner as to operation of all equipment. Instruction period to commence for minimum of (1) hour and shall be scheduled at owner's convenience. 1.10 CUTTING AND PATCHING A. The contractor shall do all cutting, drilling and patching which may be required for the installation of the work under this Section of the Specifications. B. Patching shall be of the same workmanship, material, and finish and shall match accurately all surrounding construction in a manner satisfactory to Owner. No cutting of the structure shall be permitted without written approval of Owner. 2.01 PIPING A. Interior Underground Sanitary and Waste Piping: PVC piping Schedule 40 pipes and fittings. No -hub couplings shall be Clamp -all, or MG type. B. Interior Suspended Sanitary and Vent Piping - above ground: 1.3" and Larger - Service weight (Tyseal) bell and spigot or no-hub cast iron all be Clamp -all, or MG type. 2. 2" and Smaller - Schedule 40- galvanized steel pipe with screwed Durham cast iron fittings for waste and vent or no -hub cast iron soil, pipe and fittings. 3. No -hub couplings shall be Clamp -ail, or MG type. C. Interior Domestic Water Piping: 3" and Smaller - Type "L" hard tempered copper with solder end fittings. 95 -5 tin and antimony solder jointing (lead -free). D. Condensate Drain Piping: , Copper water tube ASTM B88, Type "M ", solder with 95-5 solder, lead -free type. Condensate drainpipe in ceiling space shall be insulated with 1/2" thick Armstrong "Armaflex ", and sections butted firmly together. E. Gas Piping: Galvanized steel, ASTM -120, Schedule 40 and fittings. F. Hot and Cold Water Piping Insulation: 1. Hot water supply and return shall be 1" thickness sectional fiberglass pipe insulation with an all service jacket and adhesive self sealing laps. 2. Horizontal cold water above ceilings & cold water in exterior walls or an all service jacket and adhesive self - sealing laps. 3. Fittings shall be mitered or wrapped fiberglass insulation to match thickness specified above and covered with Zeston or equal pipe fitting covers and secured and sealed with self - sealing insulation tape. 4. Acceptable manufacturers are Manville, Owens - Coming Fiberglass, Knauft or approved equal. 2.02 PIPE FLASHINGS #4 lead with counter flashing ring by Glenco, Stoneman Engineering or approved equal. 2.04 PLUMBING FIXTURES AND TRIM: Plumbing fixtures to be furnished and installed under this contract. See plumbing fixture schedule. 2.05 PIPE HANGERS AND SUPPORTS A. Superstrut #C -711, Grinnell, or approved equal. B. Installation per manufacturer's recommendations. Insulation protection saddles at hangers or supports shall be 24 gauge galvanized sheet metal of 180 degrees by 9 inch length. C. Provide seismic hangers and pipe restraints as per local codes. D. Hanger rods shall be cadmium plated or galvanized all- thread rod. 3/8" size is the minimum size permitted. E. Size per the manufacturer's instructions and secure hangers and rods with cadmium plated hex head nuts (double nut). F. Attachments to the structure shall be suitable to match individual conditions and types of constructions per the manufacturer's instructions. PLUMBING SPECIFICATIONS 3.00 - INSTALLATION AND EXECUTION 3.01 GENERAL A. Support C.I. soil piping at 5 feet on center maximum and each joint and /or fitting. Support 1/2" and 3/4" piping at 6 feet on center maximum. Support 1" to 1 -1/2" piping at 8 feet on centers. Support 2" and larger piping at 10 feet on center maximum. Steel piping 4" and larger may be supported at 12 feet on center maximum except for Victaulic fitted piping which shall be supported at 10 feet on center maximum. 3.02 SPECIAL REQUIREMENTS, RESPONSIBILITIES AND TESTING A. Install piping generally level, free of traps and unnecessary bends, to conform to building requirements. Pipe to be free of defects, and installed to avoid any possible galvanic action by isolating dissimilar metals. B. Apply a water test to the waste, and vent systems whether in its entirety or in sections; if applied to the entire system, tightly close all openings in the piping except the highest opening, and fill the system with water to the point of overflow. If the system is tested in sections, tightly plug each opening except for the highest opening of the section under test, and fill each section with water, but test with no Tess than a 10' head of water. In testing successive sections, test at least the upper 10' of the next preceding section so that no joint or pipe in the building (except the uppermost 10' of the system) shall have been submitted to a test of less than a 10' head of water. Keep water in the system or in the portion under test for at least 24 hours before inspection starts, with the system tight at all points. C. Domestic water system shall be tested and proved tight under a pressure of not less than 150 PSI. Piping must stand the test fora period of 24 hours without leaking. D. Chlorination of the domestic cold and hot water piping systems in accordance with standard testing procedures and local health department requirements. Testing by a firm such as Bennet - Marine or equal. Submit certificate of satisfactory test results to the architect and owner. E. Gas piping system shall be tested with 150 PSIG air for one hour. F. Provide investigative services to determine locations of existing plumbing system services that are unknown due to lack of documentation. Contact jurisdictions and utilities companies to assist in determining service locations and record same on record drawings. Record invert elevations and provide dimensional information from structural elements or members. 3.03 PIPING INSTALLATION A. Make changes in size of pipe with reducing fittings; bushings will not be permitted except for bell shaped copper bushings. B. Install insulating unions in water piping between copper piping and ferrous piping or equipment - Epco, or equal. C. Install exposed polished chrome connections from fixtures or equipment with special care. Show no tool marks or threads at fittings. D. Cap openings in piping during construction. E. Provide 85% red brass pipe IPS, in connection to faucets, flush valves, hose bibbs or similar items requiring rigid piping. Extend brass pipe from fixture to point where piping can be securely fastened to building construction. All exposed piping and stop valves in connection to fixtures shall be chrome - plated brass. F. Install unions adjacent to valves and where necessary to facilitate disassembly of piping. G. Escutcheons: Fit exposed pipes passing through floors, walls or ceilings with escutcheons. Manufacture special sizes of escutcheons from steel and prime coat same. Cut in round, rectangular or square space to provide a clean appearance acceptable to the Architect. H. Support piping independently of equipment to which it is connected. I. Make copper solder joints with 95/5 solder, or silfos; clean surfaces to be joined free of oil, grease, rust or oxides and apply Flux to each joint before rough -in and make final connections to all other equipment furnished under other Divisions, requiring plumbing connections. J. Install seismic hangers & pipe restraints per local codes. 3.04 FIXTURES, DRAINS, CLEANOUTS, TRIM AND ACCESSORIES A. Protect finished surfaces from marking or damage during construction. B. Rough -in for A.D.A. requirements where necessary. C. Install in accordance with manufacturer's recommendations. 1 PLUMBING EQUIPMENT SCHEDULE 3.05 EXCAVATION AND BACKFILLING A. Concrete sawcut all concrete paving, floor slabs and asphalt paving. Also provide breakout services and offsite disposal of debris at a legal disposal site. B. Excavations shall be of a width and depth to safely install the work and trenches shall include pumping, shoring, etc. per OSHA standards. Overexcevate pipe trenches to provide a bedding material under the installed piping. C. Dispose of surplus excavated materials, rock, decayed material, other undesirable materials at a legal offsite disposal site. D. Pipe bedding and crown pipe cover to 6" over crown of pipe shall be imported sand backfill of the riverbank type free of rocks. No seawater beach sand permitted. E. Balance of backfill material may be the excavated material, free of rock, decayed material and other undesirable materials. F. All backfill shall be 95% compacted by pneumatic tamping, vibratory plate or roller machines. No jetting is permitted. 3.06 PROJECT RECORD DOCUMENTS Print and reproducible drawing will be furnished on which the contractor shall indicate the installation record as the work progresses. Upon completion, deliver the record drawings to Owner's construction manager. END OF SECTION Per it No Pius review approval is subject to errors and pions. Appreva. ` of construction documents nr ordinance. Receipt o approved the violation od of ield C py and oonditi is Wedged: D to Mt City of Tukrfla !°` rime n PiSION REVISIONS No changes shall m ade to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. REVIEWED FOR CODE COMPLIANCE APPROVED MAY - $ 2008 Of Tukwila BUI DING DPlISION EFARATE PERMIT REQUIRED FOR: mechanical L. Electrical 0 Plumbing 0 Gas Piping City of Tukwila B II -DING DIVISION A.F.F. A.P. B.F.P. B.L.V. B.V. B.G. C.D. CK.V. C.O. C.W. DN. (E) F.C.O. F.D. G. G,C,V, G.V. H.B. H.W. I.w, (N) N.I.C. NTS P.Q.C. PROVIDE P.R.V. (R) S.S. U.O.N. v. V.T.R. W.C.O. U.N. UP P1.1 SYMBOL CD- G- -� GATE VALVE OR BALL VALVE CHECK VALVE iC - 71 1 x t _ y -a LEGEND Plumbing Floor Plan DESCRIPTION SANITARY SEWER/ WASTE - BURIED SANITARY SEWER/ WASTE - ABOVE GRADE INDIRECT WASTE SANITARY VENT DOMESTIC COLD WATER DOMESTIC HOT WATER SUPPLY CONDENSATE DRAIN LINE NATURAL FUEL GAS GAS COCK - VALVE UNION FITTING PIPE DOWN PIPE UP BACKFLOW PREVENTER CLEANOUT - END OF LINE CLEANOUT - FLOOR TYPE WALL TYPE FLOOR DRAIN W/ P -TRAP HOSE BIBB VENT THROUGH ROOF BALL VALVE ACCESS PANEL/ ACCESS DOOR BALANCING VALVE PRESSURE REDUCING VALVE BELOW GRADE ABBREVIATIONS ABOVE FINISHED FLOOR ACCESS PANEL BACKFLOW PREVENTER BALANCING VALVE BALL VALVE BELOW GRADE CONDENSATE DRAIN CHECK VALVE CLEAN OUT DOMESTIC COLD WATER PIPE DOWN EXISTING FLOOR CLEAN OUT FLOOR DRAIN NATURAL GAS GAS COCK VALVE GATE VALVE HOSE BIBB DOMESTIC HOT WATER INDIRECT WASTE NEW NOT IN CONTRACT NOT TO SCALE POINT OF CONNECTION TO EXISTING ITEMS FURNISH, INSTALL AND CONNECT PRESSURE REDUCING VALVE RELOCATE SANITARY SEWERNVASTE UNLESS OTHERWISE NOTED SANITARY VENT VENT THROUGH ROOF WALL CLEANOUT UNION FITTING PIPE UP DRAWING SCHEDULE P0.1 Plumbing Legend, Schedules, and Load Calculations Valerio Architects Architecture, Design & Planning DATE: Apr 28, 2008 OAKLEY 556 SOUTHCENTER MALL TUKWILA, WA 98188 A Date DESCRIPTION. 4/26/08 REVIEW SET 4/28/08 PERMIT /BID /LL REVIEW SET This document contains information proprietary to the Architect and is furnished In confidence for the limited perupose of evaluation, bidding or review. This document or its contents may not be used for any other purpose and may not be reproduced or disclosed to others without the prior written consent of the Architect ������, Plumbing Legend, APR 3 0 2008 Schedules, and PERMIT CENTF Load Calculations Date Modified: Date Created: Scale: Project No.: Drawn By: CAD File: 5858 Wilshire Blvd, Ste 203 Los Angeles, CA 90036 Telephone: 323.954.8996 Facsimile: 323.954.8965 url: www.valerioarchitects.com Email: info@valerioarchitects.com CONSULTANT ENCON ENERGY • CONSERVATION • COMPANY mommimormi 720 Sunrise Ave, Suite 208B Roseville, CA 95661 tel # (916) 772 -8440 fax # (916) 772 -8441 email info ®encon.com Copyright o ENCON 2008 ENCON Project : 0K6118.00 t1^L7t � tl % fi e� j PROJECT 4/28/08 4/15/08 AS SHOWN 586 -08 -29 BMS /RDM ENCON 0K6181.00 FIRE SPRINKLER SPECIFICATIONS 1.01 DESCRIPTION 1.00 — GENERAL Furnish all labor, materials, equipment and services required for and /or reasonably incidental to the completion of the following work. A, Complete fire sprinkler system covering the entire store as shown. B. Connection to existing fire sprinkler mains. C. Co— ordinate with building owner representative for connections to existing sytem, D. Flashing and sealing of roof and exterior wall penetrat, for water tightneess. E. Caulking and sealing of floor and wall penetrations and formed shaft penetrations. F, Access doors where shown or required by code. G. Hangers, supports, and guides. H. Cleanup of debris and find cleanup of drains, fixtures and equipment. I. Record drawings and operating manuals. J License, permits and associated fees. K, Cutting, drilling and patching far all surfaces in relation, to fire protection work, L. Coordinate fire sprinkler alarm with building owner's representative — as required. M. Notify landlord 48hrs. in advance for sprinkler drain down. 1.02 RELATED WORK INCLUDED UNDER OTHER SECTIONS A, HVAC 15500 B. Plumbing work 15400 C, Electrical work 16000 1,03 EXAMINATION OF SITE Visit site before submitting bid and check location of all existing conditions which will affect this work, verify dimensions and locations shown on drawings and cover all costs. Contractor shall assume reasonable variations or minor omissions and shall complete proposed work without additional cost. Failure to visit site will not lessen responsibility or entitle additional compensation for work not included in proposal. 1.04 DRAWINGS The accompanying drawings shall be considered part of these specifications. Work and materials shown on the drawings and not mentioned in the specifications and vice versa shall be executed as if specifically mentioned or shown in both. The drawings shall be considered as schematic in nature and minor modifications of the work to comply with the structure as found shall be made. 1.05 RULES AND REGULATIONS A. All work and material shall be in full accordance with the latest rules and regulations of the State Fire Marshal, NFPA, and other applicable State and local rules and regulations. Nothing in these drawings or specifications shall be construed to permit work not conforming to these codes. B. Furnish without any extra charge any additional material and labor when required to comply with these laws, ordinances and codes regardless of whether shown or mentioned in these specifications of drawings. 1.06 MATERIAL SUBMITTALS A. Submit for review to Owner a complete and all— inclusive list of equipment and materials proposed for use (4 copies), accompanied by manufacturer's data sheets giving sizes, capacities, etc. Data shall be forwarded in a single package written 15 days after award of contract. B. Within 5 days after award of contract, submit 6 copies of a letter stating any materials that contractor wishes to substitute, to Owner for approval, Include such information as manufacturer's name, type of material, certified ratings, overall appearance, and necessary information to explain function and operation of material, All proposed substitutions shall be equal in quality, design, utility and appearance to material, equipment or method specified. 1,07 AS —BUILT DRAWINGS A set of floor plans will be fumished to the Contractor on which he shall indicate the installation as —built as the work progresses. Upon completion of the work, a set of reproducible drawings shall be obtained from Owner at cost, and all changes as noted on the record set of prints shall be incorporated thereon. This set of reproducibles, along with one set of blueprints, shall be delivered to Owner upon completion and before final acceptance of the project. 1.08 GUARANTEE The Contractor shall leave the entire installation in complete working order free from any defective material, workmanship or finish, He shall guarantee to repair or replace, without charge, defects due to faulty workmanship or material for period of one year from the date of filing of the Notice of Completion. 1,09 OPERATION MANUALS AND OWNER INSTRUCTIONS A. Provide complete operation and maintenance manuals covering all mechanical systems and equipment that have been installed. Three (3) copies of the manual shall be bound in hardback binders. B. Provide instructions to owner as to operation of all equipment. Instruction period to commence for minimum of (2) hours and shall be scheduled at Owner's convenience. 1.10 CUTTING AND PATCHING A. The contractor shall do all cutting, drilling and patching which may be required for the installation of the work under this Section of the Code. B. Patching shall be of the same workmanship, material, and finish and shall match accurately all surrounding construction in a manner satisfactory to Owner. No cutting of the structure shall be permitted without written approval of Owner. 2.00 MATERIALS (Use U.L, Listed and Factory Mutual approved materials, equipment). 2.01 PIPING /SPRINKLERS A. Materials shall conform to requirements in National Fire Protection Association Pamphlet 13. Sprinkler heads shall be underwriter's approved for use intended. 1, Concealed Automatic Sprinkler Head: Model: #G -1 with white cover plate by Reliable Automatic Sprinkler Company, Inc. or equal. Installation: All ceilings and soffits with gypsum board finish 2. Recessed Automatic Sprinkler Head: Model: #G with bright chrome finish head and escutcheon by Reliable Automatic Sprinkler Company, Inc. or equal. Installation: All ceilings with suspended acoustical tile and inside gypsum board light soffit (if required). 3, Surface Pendant Automatic Sprinkler Head: Model: #G with natural bronze finish head by Reliable Automatic Sprinkler Company, Inc. or equal, with friction adjustable canopy #401, egg shell with finish by Sweet & Donaldson Manufacturing Company, Installation: Toilet room with gypsum board ceiling, closet ceiling, stairs, or other non — public areas with gypsum board ceiling. 4, Upright Automatic Sprinkler Head: Model: #G with natural bronze finish head by Reliable Automatic Sprinkler Company, Inc. or equal. Installation: In all open areas with no ceiling 5. Provide three (3) extra sets of each type head fumished. B. Sprinkler pipes shall be schedule 40 black steel with Victaulic or grooved fittings. Schedule 10 — 4" and greater — rolled, grooved, not threaded. All piping shall be concealed above the finished ceilings. C. Areas Covered: The entire tenant's premises shall be fire sprinkled. D. Testing: Furnish all necessary labor, materials and equipment for conducting tests, and pay all expenses in connection therewith. Should leaks develop while testing, repairs shall be made and tests shall be repeated until a satisfactory test is obtained. 3.00 — INSTALLATION AND EXECUTION 3.01 PIPING INSTALLATION A Make changes in size of pipe with reducing fittings; bushings will not be permitted, B. Cap openings in piping during construction. C. Escutcheons: Fit exposed pipes passing through floors, walls or ceilings with escutcheons. Manufacture special sizes of escutcheons from steel and prime coat same. Cut in round, rectangular or square space to provide a clean appearance acceptable to Owners. 3.02 SPECIAL INSTRUCTIONS A, Contractor shall be cognizant of architectural reflected ceiling plan and shall locate sprinkler heads in a symmetrical pattern were possible and shall center heads in center of ceiling tile sections. B. Contractor shall submit preliminary fire sprinkler head layout to Owner for review and approval prior to start of shop drawings. Submit (4) copies to Owner or General Contractor. END OF SECTION CONNECT (N) 3/4" COLD WATER TO (E) COLD WATER LINE. (FIELD VERIFY EXACT SIZE AND LOCATION — MIN. 3/4 ") 3/4" DRESSING RM CONNE (N) 4 "SS, SERVIC (F ELD 2— MT OFFICE VERIFY XACT SIZE AND Lil ATION) Ew S.O.V. 3/4" li■■1 i!=1 T T 7 i— 1 � � HOT & COLD WATER ISOMETRIC 2 SCALE: NTS 041 0 01 (N)FCO SALES AREA "W DN., 2"V UP, 3 /4 "HW & TO MOP SINK (N) MOP SINK WITH WATER HEATER ABOVE ON BRACKETS PROVIDE CATCH PAN UNDER ATER HEATER WITH DRAIN DOWN TO MOP SINK, 3/4" 02 FCO PLUMBING FLOOR PLAN SCALE: SCALE : 1/4 " =1' -0" STOCKROOM 1 4 A ,' C SCALE: NTS 2 r, A L EWED FOR I COMPLIANCE PROVED Of Tukwila Y - 8 20179 1 NG Dmsj CONNECT (N) 2" VENT TO (E) VENT LINE. (FIELD VERIFY EXACT SIZE AND LOCATION -- MIN. 2 ") CONNECT (N) 4" SS TO (E) SS LINE, (FIELD VERIFY EXACT SIZE AND LOCATION — MIN, 4 ") WASTE & VENT ISOMETRIC Date Modified: Date Created: Scale: Project No.: Drawn By: CAD File: Valerio Architects Architecture, Design & Planning 5858 Wilshire Blvd, Ste 203 Los Angeles, CA 90036 Telephone: 323.954.8996 Facsimile: 323.954.8965 url: www.valerioarchitects.com Email: info®valerioarchitects.com CONSULTANT ENCON ENERGY • CONSERVATION • COMPANY 720 Sunrise Ave, Suite 208B Roseville, CA 95661 tel # (916) 772 -8440 fax # (916) 772 -8441 email info@encon.com Copyright © ENCON 2008 ENCON Project #:0K6118.00 DATE: s rue/ O9 Apr 28, 2008 PROJECT OAKLEY 556 SOUTHCENTER MALL T U KW I LA, WA 98188 L Date DESCRIPTION 4/26/08 REVIEW SET 4/28/08 PERMIT /BID /LL REVIEW SET This document contains information proprietary to the Architect and is fumished in confidence for the limited perupose of evaluation, bidding or review. This document or its contents may not be used for any other purpose and may not be reproduced or disclosed to others without the prior written consent of the Architect RECENe . Plumbing APR 3 0 2008 Floor Plan PERMIT CENTS 4/28/08 4/15/08 AS SHOWN 586 -08 -29 BMS /RDM ENCON OK6181.00 1.1 ?Go H1