Loading...
HomeMy WebLinkAboutPermit PG08-147 - WESTFIELD SOUTHCENTER MALL - BEN & JERRY'SBEN & JERRY'S 2800 SOUTHCENTER MALL K2688 PGO8-147 Parcel No.: 6364200010 Address: Suite No: Cityibf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PLUMBING /GAS PIPING PERMIT 2800 SOUTHCENTER MALL TUKW Permit Number: Issue Date: Permit Expires On: PG08 -147 07/01/2008 12/28/2008 Tenant: Name: Address: Owner: Name: Address: BEN & JERRY'S 2800 SOUTHCENTER MALL K2688 , TUKWILA WA WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD CA Contact Person: Name: RHETT RUSSELL Address: 5508 OYSTER BAY RD , OLYMPIA WA Contractor: Name: JEFF'S PLUMBING REPAIR INC Address: 14026 TOULOUSE CT SW , OLYMPIA WA Contractor License No: JEFFSPR925JT Phone: Phone: 360 - 970 -6849 Phone: 360 943 -6939 Expiration Date: 04/30/2010 DESCRIPTION OF WORK: PLUMBING FOR KIOSK INCLUDING GRASE INTERCEPTOR INSTALLATION. Value of Plumbing /Gas Piping: Fees Collected: $5,000.00 $196.60 Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 FIXTURE TYPE AND QUANTITY Plumbing (cont.) 0 Building sewer and each trailer park sewer 0 0 Rain water system - per drain (inside bldg) 0 0 Water heater and/or vent 1 0 Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 0 grease interceptors 0 0 Repair or alteration of water piping and/or water 1 treatment equipment 1 0 Repair or alteration of drainage or vent piping 0 0 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 1 0 Medical gas piping (6 +) inlets /outlets 1 2 Gas Piping 0 Gas piping outlets (0 -5) 0 0 Gas piping outlets (6 +) 0 * *continued on next page ** doc: UPC -10/06 PG08 -147 Printed: 07 -01 -2008 City otTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: PGO8 -147 Issue Date: 07/01/2008 Permit Expires On: 12/28/2008 Permit Center Authorized Signature: Date: 61-j 7 L W 2 I hereby certify that I have read and eiiamIned this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied , whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constructio a performance ork. orized to s d obtain this plumbing /gas piping permit. Signature: 1 J-- J Date: 7//1 08 Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -10/06 PGO8 -147 Printed: 07 -01 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: htp: / /www.ci.tukwila.wa.us PERMIT CONDITIONS 2800 SOUTHCENTER MALL TUKW BEN & JERRY'S Permit Number: Status: Applied Date: Issue Date: PG08 -147 ISSUED 05/09/2008 07/01/2008 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. * *continued on next page ** doc: Cond -10/06 PG08 -147 Printed: 07 -01 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. c— Signature: " � Date / J !: �' / Print Name: ,.R. A - 1 v f 3x 1 doc: Cond -10/06 PG08 -147 Printed: 07 -01 -2008 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: / /wwti+'. ci. tukwi la. ii'a. us Building Permit No. �- Mechanical Permit No. Plumbing /Gas Permit No.TG 0 $. )� Public Works Permit No. Project No. rob -113 (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION r n- King Co Assessor's Tax No.: 603 —0 °10 Site Address: 2.¢So0 uu i,4.� �'� Z �i Suite Number: Floor: d� Gc Tenant Name: 13€h �C) New Tenant: [V� Yes ❑..No Property Owners Name: We.4S Mailing Address: City State Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name: 4 1 C 1 ' 1 Mailing Address: E -Mail Address: �iv D Cj' %O (, 53(-6 .&j&_ , �1 Day Telephone: d r_. PJ WA- _2 State Zip b. 452.68 Fax Number: GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: CdA�e.ke- -e-� Mailing Address: i / Contact Person: l d.{r E -Mail Address: � Contractor Registration Number: (iQ.Qr 1 * 01 15-'2 bL b a • City State p Zip Day Telephone: �%,C1. 1 . 8 3>9`ct '. Fax Number: t) ..-1 • -''(Q Expiration Date: ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record Company Name: Mailing Address: Contact Person: E -Mail Address: City State �1 Zip Day Telephone: i °tag' Fax - i 311 Fax Number: ge.35. - l 99 • ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: t4 / IN-k- b.. b. . • Contact Person:W� E -Mail Address: irie� Q:W pplications Wunns- Appbemiuns On LingJ -2006 - Permit Applicatiun.doc Revised. 9.2006 bh City _ Stagy^ bp • 3&5 . 32-51 Day Telephone: Fax Number: et2k3. ✓de55 Page 1 of 6 PLUMBING AND GAS PIPING PERMIT INFORMATION - 206 -431 -3670 PLUMBING AND GAS PIIPING CONTRACTOR INFORMATION Company Name: --TJD Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: __ Contractor Registration Number: Expiration Date: Valuation of Plumbing work (contractor's bid price): $ S. a Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information):�t 1� Building Use (per Int'I Building Code): Occupancy (per Intl Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath /shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain / Sinks Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent i Additional medical gas inlets /outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors 'piping Repair or alteration of water and /or water treating equipment 1 Repair or alteration of drainage or vent piping / / Medical gas piping system serving one to five inlets /outlets for specific gas Q: Wpplicatimts\fomts- Applicetions On Line '6-2006 - Permit Applicmo.doc Revised: 9 -2006 bh Page 5 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plutnbing Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O R OR A T ZED AGENT. Signature: �--� Date: Print Name: iZ l' • I c-u S Le 1( Day Telephone: (� C'° �7o ^ g'? Mailing Address: 5-51)8 oy 1 ✓L_ nPAl QLt,�frvrt y� C.,‘4 City / 1 State Zip /i /0 9 Date Application Accepted: E` �_ Date Application Expires: V I_ (� , s/ `1 Staff Initials: / , , ' Vl/�J�(t Q:\ A ppbcationsWonas- Appliemions On Line13-2006 - Pennil Applicalion.doc Rcviscd: 9 -2006 bh Page 6of6 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http:/lwww.ci.tukwila.wa.us SET RECEIPT RECEIPT NO: R08 -02304 Initials: WER UserID: 1655 Payee: RHETT RUSSELL Payment Date: 06/25/2008 Total Payment: 948.10 SET ID: 0625 SET NAME: BEN & JERRYS SET TRANSACTIONS: Set Member Amount D08 -269 636.50 EL08 -540 144.00 PG-0 -8 7 167.60 TOTAL: 948.10 TRANSACTION LIST: Type Method Description Amount Payment Check 5139 948.10 TOTAL: 948.10 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES ELECTRICAL PERMIT - NONR PLUMBING - NONRES STATE BUILDING SURCHARGE 000/322.100 632.00 000.322.101.00.0 144.00 000.322.103.00.0 167.60 000/386.904 4.50 TOTAL: 948.10 4122 06/25 9711 TOTAL 948.10 Doc: RECSETS -06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http:/lwww.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: PG08 -147 Address: 2800 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 05/09/2008 Applicant: BEN & JERRY'S Issue Date: Receipt No.: R08 -01539 Initials: WER User ID: 1655 Payment Amount: $29.00 Payment Date: 05/09/2008 11:19 AM Balance: $167.60 Payee: RHETT RUSSELL TRANSACTION LIST: Type Method Descriptio Amount Payment Check 5127 29.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000/345.830 29.00 Total: $29.00 2208 05/09 9711 TOTAL 475.80 doc: Receipt -06 Printed: 05 -09 -2008 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISIO N 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit (206)431 -3b7 PERMIT NO. Project: P''! Lh.II 7-ef, y> Type of Inspection: 1 ff rt.', 1 1 /h4s. p.:, S Address: 2400 /14 II Ku gic Date Called: �/ Special Instructions: Date Wanted: ? -� laa..mm.. Requester: Phone No: 3`9 2S-7 gS 3 1 ® Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: Gr.oce,AwG,ft( rov',ite'e $60.0 ' ' EINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: 8• WI REVIEWED 1-UK CODE COMPLIANCE pp VE R CEI it V ED a SMITH® JAY R. �cA LOCATI , , , — 1 III cus7oYER SMITH MFG. CO.® ?' %. DIVISION OF SMITH INDUSTRIES, INC. ,': ®� . 'may POST OFFICE BOX 3237 1F-.-.7i _ -i- A ,,; /. MONTGOMERY, ALABAMA 38109-0237 (USA) '. \:'irl� y }`"., `` - TEL: 334- 277 -8520 FAX 334- 272 -7398 www.jrsmlth.com ® MEMBER OF: ,1 ,! - 4.N PER IT CENT ���, DRAWING NUMBER S8000GT ` - ,' ,.lid=! • DRIVEN _ _ _ _ _ _ - _ __ _,� GREASE INTERCO' -..i4 ._.. :.� :! ... ._ __ _ n...._ O rg ION DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCE AND CHANGE WITHOUT NOTICE WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA GREASE INTERCEPTORS WITH SEMI - AUTOMATIC DRAW -OFF FUNCTION: Used in all areas where grease, oil and fats must be intercepted and collected. Unique semi - automatic draw -off design permits removal of accumulated grease without cover removal. When specific directions are followed, accumulated grease in liquid form is discharged through the semi - automatic draw -off piping for convenient disposal. This design eliminates the messy cleaning job which must be done in ordinary types of interceptors: 5 1/2 (140) G (Cleanout) Q Grease Accumulating Cone ..^i Line 'bD --0` '''1.7' SCALE: NONE Shut-off L II nos A ;','T' Valve ,' A — MINIM — ® °= — c - -- — _ O U A 11 I� ■ s Outlet Inlet B Removable Air Relief Static Water Line Baffles DATE: 04-24 -85 — lam— FILE /p�yw yy� r D -' i ®a COPY D H F ►� Fig. 8035GT Shown APPROVED BY: TD 1 :n it Cr Fig. # t: 8 GPM Flow Rate Grease Cap Lbs. Inlet and -.Outlet Size 'A Dimensions _.. _ C.O. Plug Size Line Shut -off Valve to p c-3 ~ U v8020GT F oughing: • Dimensions Body Height Width B C D E F G H 8007GT 07 14 02 (50) 8 1/2 (215) 3 1/2 (89) 19 (485) 12 (305) 10 3/4 (275) 2 (51) 6 3/4 (175) 801OGT 8015GT 10 15 20 30 02 (50) 02 (50) 9 1/2 (240) 12 (305) 3 3/4 (95) 3 1/2 (89) 21 1/4 (540) 25 (635) 13 1/4 (335) 15 1/2 (395) 13 (330) 14 (355) 2 (51) 2 (51) 6 3/4 (175) 6 3/4 (175) 8025GT 20 25 40 50 03 (75) 03 (75) 13 (330) 15 1/4 (390) 4 (100) 4 1/2 (115) 28 1/2 (725) 30 (760) 17 (430) 19 3/4 (500) 15 3/4 (400) 16 3/4 (425) 2 (51) 2 (51) 10 (255) 10 (255) DRAWN BY: PJ 8035GT 8050GT 8075GT 35 50 75 70 100 150 03 (75) 03 (75) 04 (100) 16 (405) 17 1/2 (445) 21 1/2 (545) 5 (125) 6 3/4 (170)_ 15 1/2 (395) 32 1/2 (825) 35 1/2 (900) 50 (1270) 21 (535) 24 1/4 (615) 37 (940) 18 1/4 (465) 20 3/4 (525) 30 1/2 (775) 2 (51) 2 (51) 3 (76) 10 (255) 10 (255) 12 3/4 (325) LOW TYPE ■ 8120GT 20 40 03 (75) 7 (180) 3 1/2 (89) 38 1/2 (980) 10 1/2 (265) 21 3/4 (550) 2 (51) 10 (255) 8135GT 35 70 03 (75) _ 7 (180) 4 3/4 (120) 49 1/2 (1257) 11 3/4 (300) 27 3/4 (705) 2 (51) 10 (255) IIIIIII 8150GT 50 100 03 (75) 10 (255) 6 (150) 49 1/2 (1257) 16 (405) 27 3/4 (705) 2 (51) 10 (255) 'Available with larger inlet and outlet when specified. NOTE: Whenever an interceptor is to be installed suspended in a floor slab with a cradle or independently, proper support is Supports / support system shall be of sufficient strength and proper design for the purpose intended and meet the approval Mfg. Co. is not responsible for the design or recommendation of such supports. Upon request, Jay R. Smith Mfg. Co. must be added to compensate for the weight of the liquid / grease when full and in the flowing mode of operation. It and external) to verify they are in their proper operating order and location. REGULARLY FURNISHED: VARIATIONS: Steel Interceptor with Gray Duco Coating 12:N0-HUB Adaptor (2) Req'd Inside and Outside with Steel Cone Draw off (Specify Fig. 2646Y) Piping and Valve Line Shut -off Valve and NOTE: Dimensions shown in Flow Control Fitting. parentheses are in millimeters. - essential for safety and functional integrity of the installation. of the architect and structural engineer. Jay R. Smith will provide the weight of the specific unit. Additional weight is the responsibility of the installer to check all parts OPTIONAL MATERIALS: Acid Resistant Coating Inside - ARI En Acid Resistant Coating Outside - ARO OR Acid Resistant Coating Inside and Outside - ARIO IIIII Aluminum Cover - AC N ■_ A, W CO(Internal CI 0 0 0 CO w 03/08/04 9-30-03 Updated Draw -off Valves Revised Table 1 JJ 1 CL WEIGHT POUNDS VOLUME CUBIC FEET FIGURE NUMBER 8000 /� T SERIES ¢ m it z REV. DATE BY KD. Joanna Spencer - RE: Ben & Jerry's @ From: "Marcia Peddicord" <mpeddicord @us.westfield.com> To: "Joanna Spencer" < jspencer @ci.tukwila.wa.us> Date: 05/15/2008 2:02 pm Subject: RE: Ben & Jerry's @K2688 They will have an "under the sink" grease interceptor. I believe that the cut sheet for the grease interceptor was included in the plumbing submission. Marcia Peddicord Southcenter Expansion - Seattle 633 Southcenter, Trailer #3 Seattle, WA 98188 Phone: 206 - 802 -6071 Fax: 206 - 246 -7043 Cell: 818- 402 -8923 Personal Cell: 724 - 321 -6541 mpeddicord @westfield.com Original Message From: Joanna Spencer [mailto :jspencer @ci.tukwila.wa.us] Sent: Thursday, May 15, 2008 1:24 PM To: Marcia Peddicord Subject: Ben & Jerry's @K2688 Marcia, Would you please verify their grease waste connection. Are they having their own gr interceptor or the will connect to the existing one outside the building ? Thanks, Joanna Joanna Spencer Development Engineer City of Tukwila Public Works Department 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 -2544 phone: 206 - 431 -2440 fax: 206 - 431 -3665 jspencer@ci.tukwila.wa.us • PERMIT COORD COPY• PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: PG08 -147 DATE: 05 -09 -08 PROJECT NAME: BEN & JERRY'S SITE ADDRESS: 2800 SOUTHCENTER MALL — K2688 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Buildirl'g MI ion P jh\ W ors 0 J Fire Prevention Structural n n Planning Division Permit Coordinator 5 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 05-13-08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: — { Please Route V Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 06 -1 0-08 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Look Up a Contractor, Election or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. License Information License JEFFSPR925JT Licensee Name JEFF'S PLUMBING REPAIR INC Licensee Type CONSTRUCTION CONTRACTOR UBI 602680181 Ind. Ins. Account Id #1 Business Type CORPORATION Address 1 14026 TOULOUSE CT SW Address 2 City OLYMPIA County THURSTON State WA Zip 98512 Phone 3609436939 Status ACTIVE Specialty 1 PLUMBING Specialty 2 UNUSED Effective Date 4/30/2008 Expiration Date 4/30/2010 Suspend Date Separation Date Parent Company Previous License JEFFSPRO66DA Next License Associated License Business Owner Information Name Role Effective Date Expiration Date SHERRY, JEFFREY A PRESIDENT 04/30/2008 Bond Amount Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #1 CBIC SF4320 04/30/2008 Until Cancelled $6,000.00 04/30/2008 Savings Information Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= JEFFSPR925JT 07/01/2008 MECHANICAL LEGEND SYMBOL SYMBOL DESCRIPTION v ABBR.. HW DESCRIPTION FD -1, FUN -1 WASTE OR SOIL (W) SIZE AS SHOWN ON PLAN AFF ARCH AUTO AAV BLDG. CAP CO CONN CONT CFM CW CWV DEC F, DIA, 0 D.I. DN DWG ELEC ENT EWT EXH (E) EXIST F FCO FD FLEX FL FR GA GAL GALV. HW IN KW LBS LVG LWT MFR MAX MECH MIN NO NC NO. NTS OPER PD PH REF REQ'D RM TEMP TYP UG UNO V W/ W F° ABOVE FINISHED FLOOR ARCHITECTURAL AUTOMATIC AUTOMATIC AIR VENT BUILDING CAPACITY CLEANOUT CONNECTION, CONNECT CONTINUE, CONTINUATION CUBIC FEET PER MINUTE COLD WATER COMBINATION WASTE VENT DEGREE FAHRENHEIT DIAMETER DUCTILE IRON DOWN DRAWING ELECTRICAL, ELECTRIC ENTERING ENTERING WATER TEMPERATURE EXHAUST EXISTING EXISTING FIRE FLOOR CLEAN OUT FLOOR DRAIN FLEXIBLE FLOOR FLOOR RECEPTOR GAUGE GALLON GALVANIZED HOT WATER INCH KILOWATT POUNDS LEAVING LEAVING WATER TEMPERATURE MANUFACTURER MAXIMUM MECHANICAL MINIMUM NORMALLY OPEN NORMALLY CLOSED NUMBER NOT TO SCALE OPERATING PRESSURE DROP PHASE REFERENCE REQUIRED ROOM TEMPERATURE TYPICAL UNDERGROUND UNLESS NOTED OTHERWISE VENT WITH WASTE 2 " u VENT V ( ) JR SMITH FIG. 3821T, WITH 6 "0 FUNNEL, ALUMINUM DOME STRAINER GI -1 COLD WATER (CW} 3" 3" - HOT WATER (HW) JR SMITH FIG. 8015GT, 15 GPM FLOW RATE, 30 LB GREASE CAPACITY, W/ OUTLET VALVE & GREASE DRAW OFF VALVE. MAX DIMENSIONS: 26 "L x 17 "W x 15-1/2"H. 208/1 W/ RELIEF VALVE, DRAIN VALVE HOT WATER CIRCULATING (HWC) PIPE UP O PIPE DOWN - w �- - C ISOLATION VALVE (BALL TYPE) ( ) � � CHECK VALVE � UNION _ CONCENTRIC REDUCER I> THERMOMETER RELIEF VALVE OR SAFETY VALVE 1 Q FLOOR CLEANOUT (FCO) POINT OF CONNECTION TO EXISTING PLUMBING FIXTURE SCHEDULE SYMBOL DESCRIPTION W v CW HW REMARKS FD -1, FUN -1 FLOOR DRAIN W/ FUNNEL SIZE AS SHOWN ON PLAN JR SMITH FIG. 3510, WITH 6" DIA TOP STRAINER, FUNNEL, & TRAP PRIMER CONN. FUNNEL DRAIN 3 2 " u W JR SMITH FIG. 3821T, WITH 6 "0 FUNNEL, ALUMINUM DOME STRAINER GI -1 GREASE INTERCEPTOR 3" 3" - - JR SMITH FIG. 8015GT, 15 GPM FLOW RATE, 30 LB GREASE CAPACITY, W/ OUTLET VALVE & GREASE DRAW OFF VALVE. MAX DIMENSIONS: 26 "L x 17 "W x 15-1/2"H. 208/1 W/ RELIEF VALVE, DRAIN VALVE (9E) * COMBINATION WASTE VENT (CWV) SYSTEM USED, NOT ALL FIXTURES HAVE VENTS CONNECTED TO FIXTURE PIPING. MATER HEATER SCHEDULE SYMBOL SPECIFIED MFR. AND SERIES NO. TYPE AREA SERVED INPUT STORAGE (GAL) DOMESTIC HW ELECTRICAL REMARKS • • GPH EWT LWT FLA VOLTS /PH A.O. SMITH DEL 10 ELECTRIC TANK HW 6 KW 10 31 40 120 28.8 208/1 W/ RELIEF VALVE, DRAIN VALVE (9E) 1 3 4 5 6 7 8 9 10 A I B S P E C I F I C A T I O N S 15010 - GENERAL 1. CODE COMPLIANCE: ALL WORK SHALL COMPLY WITH ALL LOCAL CODES AND ORDINANCES. 2. DRAWINGS: DRAWINGS ARE DIAGRAMMATIC AND SHOW THE GENERAL ARRANGEMENT OF THE CONSTRUCTION, AND THEREFORE DO NOT SHOW ALL NECESSARY OFFSETS, FITTINGS, AND ALTERATIONS TO EXISTING ITEMS, AND ACCESSORIES WHICH ARE REQUIRED TO FORM COMPLETE AND OPERABLE SYSTEMS. 3. FIELD VERIFICATION: THE CONTRACTOR SHALL BE RESPONSIBLE FOR CHECKING FIELD CONDITIONS, REVIEWING EXISTING RECORD DRAWINGS, AND VERIFYING ALL MEASUREMENTS AND RELATIONSHIPS INDICATED ON THE DRAWINGS BEFORE SUBMITTING BIDS AND AGAIN BEFORE PROCEEDING WITH THE WORK. 4. PERMITS AND FEES: THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, LICENSES, FEES AND INSPECTIONS AS REQUIRED BY THE GOVERNING CODES AND AS SPECIFIED HEREIN. (UNO). 5. SUBMITTALS: CONTRACTOR SHALL SUBMIT PRODUCT DATA INFORMATION FOR ALL PRODUCTS PROPOSED TO BE USED ON THIS PROJECT FOR OWNER REVIEW. PRODUCTS SHALL NOT BE USED UNTIL APPROVED BY THE OWNER OR HIS REPRESENTATIVE. SUBMIT 3 COPIES PLUS ANY ADDITIONAL QUANTITIES THE CONTRACTOR NEEDS (3 COPIES WILL BE RETAINED BY THE OWNER). 6. RECORD DRAWINGS: THE CONTRACTOR SHALL MAINTAIN A SET OF CONTRACT PLANS AT THE PROJECT SITE UPON WHICH ALL CHANGES FROM THE AS -BID PLANS ARE NOTED. AT THE COMPLETION OF THE PROJECT, THE CONTRACTOR SHALL DELIVER TO THE OWNER ONE COMPLETE SET OF THESE RECORD DRAWINGS. 7. PROTECTION: CONTRACTOR IS RESPONSIBLE FOR PROTECTION OF ALL MATERIAL, EQUIPMENT AND APPARATUS PROVIDED UNDER THIS SECTION FROM DAMAGE, WATER, CORROSION, FREEZING AND DUST, BOTH IN STORAGE AND WHEN INSTALLED, UNTIL FINAL PROJECT ACCEPTANCE. 8. COORDINATION: THE CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ACTIVITIES WITH THE OWNER AND COOPERATE FULLY SO AS TO MINIMIZE CONFLICTS AND TO ALLOW FULL OWNER USAGE (UNLESS INDICATED OTHERWISE) OF ALL AREAS DURING CONSTRUCTION. 9. CUTTING AND PATCHING: SHALL BE DONE BY SKILLED LABOR EXPERIENCED IN PROVIDING OPENINGS AND PATCHING OF THE MATERIALS INVOLVED. AREAS SHALL BE PATCHED AND RESTORED TO A FINISHED CONDITION, EQUAL TO ADJACENT FINAL FINISHED AREAS THAT HAVE NOT BEEN CUT, 10. PAINTING: SHALL BE PROVIDED WHERE INDICATED, BY SKILLED PAINTERS IN CONFORMANCE WITH STANDARD PROFESSIONAL PRACTICE INCLUDING CLEANING AND PRIMING OF MATERIALS TO BE PAINTED. COLORS SHALL BE SELECTED BY THE OWNER 11. FINAL INSPECTION: PRIOR TO ACCEPTANCE OF THE WORK, THE CONTRACTOR SHALL PUT ALL SYSTEMS INTO OPERATION FOR A PERIOD OF NOT LESS THAN 5 WORKING DAYS SO THAT THEY MAY BE INSPECTED BY THE OWNER. 12. WARRANTY: ALL WORK AND EQUIPMENT SHALL BE WARRANTED TO BE FREE FROM DEFECTS AND CAPABLE OF PROVIDING SATISFACTORY OPERATION FOR A PERIOD OF ONE YEAR. SEE GENERAL CONDITION FOR MORE INFORMATION. 13. NEW MATERIALS: ALL ITEMS ARE NEW UNLESS SPECIFICALLY NOTED AS EXISTING. 14. COMPLETE SYSTEMS: NOT ALL NECESSARY MATERIALS TO PERFORM THE WORK REQUIRED ARE SPECIFIED OR SHOWN. CONTRACTOR SHALL PROVIDE ALL ITEMS NEEDED TO HAVE COMPLETED PROPERLY OPERATING SYSTEMS; ITEMS PROVIDED SHALL BE OF COMMERCIAL /INSTITUTIONAL QUALITY, CONSISTENT WITH THE QUALITY OF RELATED ITEMS PROVIDED ON THE PROJECT OR CURRENTLY BEING USED IN THE BUILDING. 15. IDENTIFICATION: . A. PIPING: SHALL BE MARKED ON 20 FOOT CENTERS WITH SELF - STICKING COLORED MARKERS, LETTERED TO IDENTIFY THE PIPE CONTENTS, AND BANDED AT EACH END WITH ARROW TAPE INDICATING THE DIRECTION OF FLOW. MARKERS SHALL BE SIMILAR AND EQUAL TO BRADY "SYSTEM 1." LETTERING AND COLORS SHALL COMPLY WITH ANSI A13.1. EXCEPT THAT WHERE EXPOSED TO VIEW TO GENERAL MALL PATRONS, NO LABELING IS REQ'D. B. VALVES: SHALL ALL BE MARKED WITH IDENTIFICATION TAGS MADE OF BRASS OR ALUMINUM, STAMPED WITH VALVE NUMBER AND ABBREVIATION OF SYSTEM SERVED. COORDINATE WITH OWNER FOR NUMBERING AND I.D. TO BE USED. LABEL AS- BUILTS W/ VALVE ID NUMBERS ASSIGNED. 16. TESTING: ALL PIPING AND SYSTEMS SHALL BE PRESSURE TESTED PER CODE REQUIREMENTS AND TO AT LEAST 1.5 TIMES THE SYSTEMS ALLOWED OPERATING PRESSURE AND IN ACCORDANCE WITH CODE AND THE OWNER'S STANDARDS. 17. CONTRACTOR LAY -OUT: THE CONTRACTOR IS REQUIRED TO DO FURTHER LAYOUT TO FINALIZE THE DESIGN SHOWN ON THE PROJECT DRAWINGS. SUCH WORK INCLUDES FIELD INVESTIGATION OF ALL EXISTING CONDITIONS, LAYOUT SKETCHES TO VERIFY RISES AND DROPS IN PIPING AND COORDINATION WITH EXISTING ITEMS. 18. INSTRUCTION /0 & M MANUALS: DURING THE FINAL INSPECTION PERIOD, THE CONTRACTOR SHALL PROVIDE INSTRUCTIONS AND DEMONSTRATIONS FOR THE OWNER'S REPRESENTATIVES ON THE OPERATION AND MAINTENANCE OF ALL EQUIPMENT, AND PROVIDE 3 SETS OF O &M MANUALS. 0 & M MANUALS SHALL INCLUDE CONTACT INFORMATION FOR ALL CONTRACTORS AND SOURCES FOR ALL PRODUCTS, AND FACTORY 0 & M MANUALS FOR ALL EQUIPMENT. 19. ALL ITEMS DAMAGED IN THE COURSE OF PERFORMING THE WORK OF THIS PROJECT SHALL BE REPAIRED TO PRE - CONSTRUCTION CONDITIONS OR BETTER. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING EXISTING EQUIPMENT, WIRING, DUCTS AND OTHER ITEMS IN AREAS WHERE WORK IS BEING PERFORMED. THE CONTRACTOR SHALL TAKE NECESSARY STEPS TO PROTECT SUCH ITEMS FROM DUST, DEBRIS AND WATER DAMAGE. 20. PROVIDE BARRICADES & SIMILAR PROTECTIONS TO KEEP NON - CONSTRUCTION PERSONNEL CLEAR OF CONSTRUCTION AREAS. 21. THE PROVISIONS OF THE INSTRUCTIONS TO BIDDERS, GENERAL CONDITIONS, SUPPLEMENTARY CONDITIONS, ADDENDAS AND DIVISION 1 ARE A PART OF THIS SPECIFICATION. ELECTRICAL, ARCHITECTURAL, AND ALL OTHER DRAWINGS AS WELL AS THE SPECIFICATIONS FOR ALL THE DIVISIONS ARE A PART OF THE CONTRACT DOCUMENTS. 22. UNSIZED PLUMBING PIPING SHALL MATCH THE SIZE OF THE LARGEST ADJACENT CONNECTING PIPE SIZE SHOWN, WHERE THE ADJACENT PIPE IS NOT SHOWN (OR NOT CLEAR), THE PIPE SIZE SHALL BE BASED ON THE GPM FLOWING IN THE PIPE (USE TOTAL OF COILS SERVED FOR HYDRONIC SYSTEM, USE FIXTURE UNITS AND CORRESPONDING GPM PER THE UPC FOR DOMESTIC WATER SYSTEMS, USE WASTE FIXTURE UNITS & UPC TABLES FOR WASTE /VENT SYSTEM), AND A VELOCITY NO GREATER THAN 4 FEET PER SECOND. USE UPC CURVES FOR GPM /VELOCITY FOR APPROPRIATE PIPING MATERIAL INVOLVED. A B C 15060 - PIPE AND PIPE FITTINGS 1. DOMESTIC WATER PIPE AND FITTINGS: TYPE L COPPER, PER ASTM B88, SOLDER FITTINGS PER ANSI B16.22/016.24. 2. WASTE & VENT PIPING: SERVICE WEIGHT NO -HUB CAST IRON PER CISPI 301 AND ASTM A 888, FOR USE W/ NO -HUB COUPLINGS. COUPLINGS SHALL COMPLY W/ CISPI 310 OR ASTM C 1277. OR, SCHEDULE 40 GALVANIZED STEEL PIPE PER ASTM A 53, WITH CAST IRON DRAINAGE FITTINGS PER ASME B 16.12 & B 16.4. 3. TRAP PRIMER PIPING: TYPE K SOFT COPPER WITH NO JOINTS FROM TRAP PRIMER TO DRAIN. 4. INSTALLATION: A. INSTALL PIPING CONCEALED UNLESS SPECIFICALLY NOTED OTHERWISE. COORDINATE WITH OTHER TRADES AND ALL EXISTING CONDITIONS. INSTALL TO ALLOW MAXIMUM ACCESS TO COMPONENTS INSTALLED IN PIPING SYSTEM. B. FOLLOW ESTABLISHED PROFESSIONAL PRACTICES FOR JOINING OF PIPING AND SO AS TO SUIT THE SYSTEM PRESSURES AND TEMPERATURES INVOLVED. 15080 -- PIPING SPECIALTIES 1. THERMOMETERS: DIAL BIMETAL TYPE, 3 -INCH DIAL SIZE, BRASS OR STAINLESS STEEL CONSTRUCTION, WHITE FACE WITH BLACK NUMERALS, AND MARKINGS IN DEGREES F. PROVIDE SOCKETS WITH EXTENSION NECKS WHERE INSTALLED ON INSULATED PIPING. THERMOMETER TEMPERATURE RANGE FOR DOMESTIC HOT WATER: 0 TO 200 DEGREES F. 2. WATER STRAINERS: "Y" TYPE, SAME SIZE AS THE PIPE IN WHICH THEY ARE INSTALLED, WITH BRONZE RATED FOR 125 PSI WORKING PRESSURE, AND WITH REMOVABLE PLUG AND SEDIMENT SCREEN. BASKET SCREEN SHALL BE STAINLESS STEEL OR MONEL, 20 MESH, WITH A NET FREE AREA OF AT LEAST 3 TIMES THAT OF THE ENTERING PIPE. PROVIDE WITH BLOWDOWN VALVE. 3. UNIONS: RATED AT MINIMUM 125 PSIG AT 200 DEGREES F; PROVIDE DIELECTRIC UNIONS WHERE DISSIMILAR METALS JOIN. PROVIDE UNIONS AT CONNECTIONS TO ALL EQUIPMENT. 4. ESCUTCHEONS: SHALL BE CHROME PLATED, PROVIDE FOR ALL EXPOSED PIPING AT WALL, FLOOR, CEILING AND SIMILAR PENETRATIONS. 5. CLEANOUTS: A. FLOOR TYPES: J.R. SMITH FIG. 4025, SATIN BRONZE TOP. B. WALL TYPE: J.R. SMITH FIG. 4422, DUCO CAST IRON FERRULE, BRONZE PLUG, STAINLESS STEEL COVER. 6. TRAP PRIMER VALVE: PRECISION PLUMBING PRODUCTS MODEL P -1 AND P -2, WITH ADJUSTABLE OPERATION. 7. DOMESTIC WATER EXPANSION TANK: DIAPHRAM TYPE, WELDED STEEL WITH HEAVY DUTY BUTYL DIAPHRAM AND RIGID POLYPROPYLENE LINER, CHARGING VALVE AND TANK FITTINGS. 8. ACCESS DOORS: STAINLESS STEEL CONSTRUCTION, MINIMUM 16 GUAGE, W/ FULL PIANO TYPE HINGE, & KEYED LOCKING MECHANISM. 15090 - HANGERS. SUPPORTS, SLEEVES AND SEALS 1. PIPE HANGERS AND SUPPORTS: A. GENERAL: SHALL CONFORM TO MSS SP -58 AND MSS SP -69 AND SHALL BE COPPER PLATED WHERE IN CONTACT WITH COPPER PIPE OR BE PROVIDED WITH FACTORY MADE SOLATORS TO PREVENT CONTACT OF DISSIMILAR MATERIALS. UNISTRUT SHALL NOT BE USED TO SUPPORT HORIZONTAL PIPING, EXCEPT WHERE RACKED AGAINST A WALL AND NO OTHER SUPPORT MEANS IS REASONABLE. ALL STEEL HANGERS SHALL BE CADMIUM PLATED, OR BE GALVANIZED STEEL. C B. HANGERS: SHALL PERMIT ADEQUATE ADJUSTMENT AFTER ERECTION WHILE STILL SUPPORTING THE LOAD. PIPE GUIDES AND ANCHORS SHALL BE INSTALLED TO KEEP PIPES IN ACCURATE ALIGNMENT, TO DIRECT EXPANSION MOVEMENT, AND TO PREVENT BUCKLING, SWAYING, AND UNDUE STRAIN. C. SPACING: SHALL BE SPACED AS SPECIFIED IN MSS SP-69 AND BY CODE, AND A SUPPORT SHALL BE INSTALLED NOT OVER 1' FROM THE PIPE FITTING JOINT AT EACH CHANGE IN DIRECTION OF THE PIPING (FOR PIPING 2" AND LARGER). D. INSULATION: SHALL BE CONTINUOUS THROUGH ALL SUPPORTS, PROVIDE INSULATION SUPPORTS PER SEC 15250. 2. PIPE SLEEVES AND SEALS: SLEEVES SHALL BE FABRICATED OF 20 GAUGE SHEETMETAL AND SHALL ALLOW 1/2" SPACE AROUND INNER PIPE AND SHALL EXTEND AT LEAST 1" BEYOND PENETRATED ELEMENT SURFACES. PROVIDE SLEEVES AT ALL WALL, FLOOR, AND CEILING PENETRATIONS (EXCEPT WHERE COMPLETELY SOLID INTERIOR ELEMENTS SUCH AS CONCRETE SLABS ARE PENETRATED). SEAL BETWEEN SLEEVE AND PIPE WITH UL APPROVED FIRE SEALANT; (EXCEPT WHERE FIRE /SMOKE SEPERATION IS NOT REQUIRED PROVIDE SILICON TYPE SEAL OR ROCK WOOL.). SEAL BETWEEN SLEEVE AND ELEMENT PENETRATED WITH SAME MATERIAL ELEMENT IS CONSTRUCTED OF (I.E., CONCRETE, PLASTER, ETC.). ALL SEALING SHALL BE PROVIDED SO AS TO MAINTAIN THE FIRE & SMOKE RATING OF THE ELEMENT BEING PENETRATED. 15100 -- VALVES 1. ACCEPTABLE MANUFACTURERS: NIBCO, RED-WHITE, MILWAUKEE, APOLLO, HAMMOND, WATTS. 2. COLD WATER AND HOT WATER SERVICE: 125 PSI -SWP BRONZE BODY BALL VALVES, FULL PORT, NIBCO 5580, T580, OR EQUAL. 3. CHECK VALVES: 125 PSI -SWP BRONZE HORIZONTAL SWING TYPE. NIBCO S -413, T -413, OR EQUAL. 4. DRAIN VALVES: NIBCO S-585-70-HC, T- 585- 70 -HC, OR EQUAL. 5. BACKFLOW PREVENTORS: WASHINGTON STATE APPROVED, TYPE AS INDICATED. INSTALL WITH UNION CONNECTIONS, UPSTREAM STRAINER AND TO BE ACCESSIBLE. 6. INSTALLATION: INSTALL VALVES WITH STEM VERTICAL AND HANDLE UP WHEREVER POSSIBLE; IN NO CASE BELOW HORIZONTAL. INSTALL IN LOCATION FOR EASE OF ACCESS. INSTALL ALL VALVES IN STRICT ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS; RELIEF VALVES SHALL HAVE FULL SIZE INLET ANT OUTLET CONNECTIONS. 15250 -- INSULATION PIPING INSULATION: RIGID FIBERGLASS INSULATION, THERMAL CONDUCTIVITY SHALL NOT EXCEED 0.24 BTU - INCH /HR- SQ.FT.- DEGREES F. AT 75 DEGREES F. WITH JACKET CONSISTING OF HIGH DENSITY WHITE KRAFT BONDED TO ALUMINUM FOIL, WITH PRESSURE SENSITIVE CLOSURE SYSTEM, INTEGRAL VAPOR BARRIER WITH 0.02 PERM RATING. INSULATE ALL DAMAGED (IN THE COURSE OF THIS PROJECT) EXISTING PIPING INSULATION. PROVIDE INSULATION ON ALL HW, CW, HWC PIPING AS REQUIRED BY THE ENERGY CODE, BUT NO LESS THAN 1/2" INCH THICK. 2. HANGER INSERTS: EXPANDED PERLITE OR CALCIUM SILICATE INSULATION; WITH NO MORE THAN 5% DEFORMATION AT 100 PSI; AND MAXIMUM CONDUCTIVITY OF 0.32 BTU- IN /HR- SQ.FT.- DEGREE F; WITH MINIMUM 18 GAUGE GALVANIZED STEEL SHIELDS. MICHIGAN HANGAR CO. NOS. 124, 1031, 4031; OR EQUAL. PROVIDE 360° TYPE INSERT WHERE PIPE IS CLAMPED FOR SUPPORT. D E E F 3. PIPING INSULATION INSTALLATION: A. PROVIDE INSULATION ON THE SURFACES OF ALL ENERGY CONVEYING, ENERGY CONSUMING, OR ENERGY STORAGE DEVICES (I.E. PIPES, EQUIPMENT, VALVES, FITTINGS, ACCESSORIES, ETC.) INSTALLED AS PART OF THIS PROJECT EXCEPT WHERE SPECIFICALLY EXCLUDED. PROVIDE INSULATION ON ALL ITEMS WHERE EXISTING •ASBESTOS INSULATION WAS REMOVED OR EXISTING INSULATION WAS DAMAGED. B. PROVIDE INSULATION CONTINUOUS THROUGH ALL SUPPORTS USING HANGER INSERTS. 15450 - PLUMBING FIXTURES AND WATER HEATERS 1. GENERAL: PROVIDE ALL STOPS, TRAPS, ESCUTCHEONS, CONNECTIONS, CARRIERS ETC., FOR ALL FIXTURES AS NECESSARY TO COMPLETE THE INSTALLATION OF EACH FIXTURE, WHETHER SUCH ITEMS ARE LISTED OR NOT. STOPS SHALL BE QUARTER TURN BALL TYPE, BRASSCRAFT. 2. THE WATER HEATER(S) SHALL HAVE CAPACITY AS SCHEDULED, AND BE FOR USE WITH ELECTRICITY OF VOLT /PH INDICATED, AND BE LISTED BY UNDERWRITER'S LABORATORIES. HEATER(S) SHALL HAVE 150 PSI WORKING PRESSURE AND BE EQUIPPED WITH EXTRUDED HIGH DENSITY ANODE ROD. ALL INTERNAL SURFACES OF THE HEATER(S) EXPOSED TO WATER SHALL BE GLASS -LINED WITH AN ALKALINE BOROSILICATE COMPOSITION THAT HAS BEEN FUSED TO STEEL BY FIRING AT A TEMPERATURE RANGE OF 1600 °F. ELECTRIC HEATING ELEMENTS SHALL BE MEDIUM WATT DENSITY WITH ZINC PLATED COPPER SHEATH. EACH ELEMENT SHALL BE CONTROLLED BY AN INDIVIDUALLY MOUNTED THERMOSTAT AND HIGH TEMPERATURE CUTOFF SWITCH. THE OUTER JACKET SHALL BE OF BAKED ENAMEL FINISH AND SHALL BE PROVIDED WITH FULL SIZE CONTROL COMPARTMENT FOR PERFORMANCE OF SERVICE AND MAINTENANCE THROUGH HINGED FRONT PANELS AND SHALL ENCLOSE THE TANK WITH FOAM INSULATION. TANK SHALL HAVE DRAIN VALVE, LOCATED IN THE FRONT FOR EASE OF SERVICING. HEATER TANK SHALL HAVE A THREE YEAR WARRANTY. 3. FLOOR DRAINS: GALVANIZED CAST IRON BODY, NICKEL BRONZE ADJUSTABLE STRAINER HEAD, ROUND NICKEL BRONZE GRATE, REVERSIBLE FLASHING COLLAR, AND TRAP PRIMER CONNECTION. PROVIDE WITH 4" DIAMETER FUNNEL WHERE USED TO SERVE RELIEVE VALVES OR INDIRECT WASTES. 4. FLOOR RECEPTOR: CAST IRON FLANGED RECEPTOR WITH ACID RESISTANT COATED INTERIOR, NICKEL BRONZE RIM, DOME BOTTOM STRAINER, NICKEL BRONZE 1/2 GRATE, AND TRAP PRIMER CONNECTION. INSTALL FLUSH WITH FINISHED FLOOR. 5. FUNNEL DRAINS: CAST IRON FUNNEL DRAIN W/ P -TRAP, WITH. ACID RESISTANT COATING INSIDE & OUT. 6. GREASE INTERCEPTOR: MINIMUM CAPACITY AS SCHEDULED, AND DIMENSIONS TO SUIT SPACE AVAILABLE. STEEL CONSTRUCTION W/ ACID RESISTANT COATING 'INSIDE & OUT, FOR ABOVE FLOOR MOUNTING PROVIDE W/ SEMI - AUTOMATIC DRAW OFF VALVES, & FLOW CONTROL FITTING. PROVIDE EXTRA FLOW CONTROL FITTING TO SERVE INDIRECT DRAIN PIPING. F G H FILE COPY Permit No Mar review approval Is SL Approval of conshuction documents or �• Receipt the violation of any adopted led: of approved Field Copy and =Mons Is BY Date:, J City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. Pk1.08 J 147 K coo APPOVED BOSOG 150 SEPARATE PERMIT REQUIRED FOR: WMechanical s' Electrical ❑ Plumbing ❑ Gas Piping City of Tukwila BUILDING DIVISION K RECEIVED MAY - 9 2008 PERMIT CENTER 2 3 4 5 6 10 design group AMERICAN INSTITUTE OF ARCHITECTS I EXPIRES ' -I4 -OS HELIX DESIGN GROUP, INC HULTZ qffl BHU-f C ROSS consulting engineers, Inc. 2407 North 31st Street Phone: (253) 383 -3257 general@hullzbhucross.com MECHANICAL 7 LEGEND, NOTES & SCHEDULES BEN & JERRY'S KIOSK 8 SOUTHCENTER MALL TUKWILLA , WA REVISION DATE DATE JOB NO. 05.02.08 108 -043 PERMIT SET DRAWING NO, Tacoma, WA 98407 Fax: (253) 353 -3283 Job Number: 09.091 6 of 9 'f. HELIX DESIGN GROUP, INC.: nil rights reserved. A 1 2 3 4 5 6 7 8 9 FLOW CONTROL FITTING #2 FUN- -1 ® GI -1 j 3 "W LINE SHUT —OFF VALVE, FURNISHED W/ GI -1 4" FCO 2" FD -1 A 2 "V 4 "(CWV) NTS 4 "(CWV) PIPE FULL SIZE TO FLOOR DRAIN R--10 RIGID INSULATION 1" DRAIN PIPED TO FLOOR DRAIN NTS ACCESS DOOR (WHERE CONCEALED IN WALL) 1/2" (TYP), TYPE K SOFT COPPER, W/ NO JOINTS NTS SIZE TO MATCH FLOW CONTROL FITTING CONN. FLOW CONTROL FITTING #1 CO — Tr 3" ( C WV) B B " HW WATER HEATER F' !/////1/// WATER HEATER DETAIL CW LINE TO FREQUENTLY USED FIXTURE (OR LINE AS INDICATED ON PLAN) r L NOTE: LOCATE TO BE ACCESSIBLE. LOCATION ON PLANS IS PRELIMINARY ONLY, CONTRACTOR TO CONFIRM. TRAP PRIMER DETAIL WASTE FROM 3— COMPARTMENT SINK 3 "V ti 3 "V 3"(CWV) CO 2" FD -1 WASTE VENT RISER DIAGRAM REDUCER (TYP) 4 "(CWV) 4 "W C CABINET, SEE ARCH DRAWINGS 1" CW I HOSE END THREADED DRAIN VALVE W/ CAP TO FIXTURE (OR AS SHOWN) 6" HIGH SQUARE DRAIN PAN, MIN 20 GA. GALV., WELDED STEEL CONSTRUCTION, WATERTIGHT TRAP PRIMER VALVE ADJUSTABLE TYPE PRIMER MANIFOLD(S) (WHERE SERVING MORE THAN ONE FLOOR DRAIN) r FINISHED FLOOR TO FLOOR DRAIN TRAP (TYP.) EXPANSION TANK THERM--- X --TROL ST -5 CHARGE TO BLDG. STATIC PRESSURE LEVEL, LOCATE REMOTE FROM CABINET 3 "V, CONN TO (E) 3 "V & ON TO t I (E) VTR C (E) 4 "W — 2 " S D FLOOR PENETRATION, SEAL & PROVIDE ESCUTCHEON (TYP) D 2 "V EXPANSION TANK FUN - 1 SINK WASTE (TYP) 0 GI -1 OUTLINE OF KIOSK ABOVE E E / 3 "V ®2"V, 3 /4 "CW, 3/4 "H W rr -- t t n-. 4 "W UP — 4 "W 3 "V, 1 "CW 1 /2 "H W 2" FD -1 SCALE: I/2 " =1' —a PROVIDE FULL SIZE TRAP (SAME SIZE AS BRANCH LINE) W/ REDUCER TO FIXTURE CONN SIZE (TYP) 1/2" TO 11E 2" ED -1 1 /2 "CW UP - a 3 " r r (c ) „____ 1 /2" CW 3 "W (CWV) SCALE: I/2 rILO' 1 /2 "CW DN THRU FLOOR 4E F 1 /2 "CW UP 3 "V 4 "W 7 (CWV) F 1 G NOTE: PIPING RUNS IN CEILING SPACE BELOW KIOSK (UNO). ABOVE FLOOR PLUMBING PLAN r UNDER FLOOR PLUMBING PLAN � rl non FP- 01.DIAl M2 FP- 01.DWG 2 "W DN THRU FLOOR tc �t-- �7 rEM M2.0 1 "CW UP 1 "CW 1 "CW UP THRU FLOOR PROVIDE W/ ISOLATION VALVE ABOVE FLOOR H H J GENERAL NOTES 1 SEE ARCHITECTURAL PLANS, KIOSK EQUIPMENT SCHEDULE, & SPECIFICATIONS FOR REQ'D PLUMBING CONNECTIONS TO ITEMS IN THE KIOSK. ALL ITEMS REQUIRING PLUMBING CONNECTIONS SHALL BE COMPLETELY CONNECTED BY THE PLUMBING CONTRACTOR. THIS INCLUDES PROVIDING ALL HW /CW /WASTE /VENT /MISC DRAIN PIPING, TRAPS, FITTINGS, STOPS (IN ALL WATER PIPING TO ITEMS), VALVES, SOLENOID VALVES, GASKETS, UNIONS, VACUUM BREAKERS, BACKFLOW PREVENTORS, ESCUTCHEONS, WATER HAMMER ARRESTERS, ACCESS DOORS, PIPE SHROUDS, & ALL ACCESSORIES. 2. FOR PIPING SIZES TO INDIVIDUAL PLUMBING ITEMS SEE ARCHITECTURAL PLANS, KIOSK EQUIPMENT SCHEDULE, PLUMBING FIXTURE SCHEDULE & SPECIFICATIONS. 3. THE PLUMBING CONTRACTOR SHALL INSTALL ALL FITTINGS, VALVES & CONTROLS FURNISHED WITH THE FOOD SERVICE EQUIPMENT AS LOOSE ITEMS, AND SHALL PROVIDE ALL INTERCONNECTION PIPING REQUIRED TO COMPLETE EACH EQUIPMENT HOOK —UP FOR PROPER OPERATION & CONNECTIONS TO PLUMBING SERVICES. 4. C # ) DESIGNATES KIOSK EQUIPMENT ITEMS. SEE ARCHITECTURAL DRAWINGS. 5. VERIFY LOCATIONS OF ALL ITEMS W/ OTHER TRADES BEFORE BEGINNING WORK. 6. SUBMIT SHOP DRAWINGS WITH DIMENSIONED LOCATION OF ALL FLOOR DRAINS & FLOOR RECEPTORS BEFORE INSTALLING. 7. VERIFY ADEQUATE SPACE FOR WATER HEATER BEFORE ORDERING. 8. VERIFY CONNECTION LOCATIONS & REQUIREMENTS OF ALL ITEMS PRIOR TO BIDDING. PLANS ARE SCHEMATIC ONLY & DO NOT SHOW ALL NECESSARY OFFSETS, PIPE LENGTHS, & ACCESSORIES FOR FULL CONNECTIONS. 9. LOCATION OF EXISTING ITEMS IS BASED ON INFORMATION PROVIDED BY OTHERS, AND HAS NOT BEEN FIELD VERIFIED. KEYED NOTES CONNECT TO EXISTING. FIELD VERIFY SIZE & LOCATION. ASSUME LOCATION IS 20 FEET AWAY FROM LOCATION NOTED, REQUIRING 2 ADDED FITTINGS. (UNLESS FIELD VERIFIED PRIOR TO BIDDING). 0 1/2" DOUBLE CHECK BACKFLOW PREVENTOR. 0111101 J K 0 1/2" TRAP PRIMER LINE. 0 PROVIDE TRAP PRIMER TO SERVE ADJACENT DRAINS. SEE DETAIL 2/M2.0 0 RUN ALL PIPING IN WALL, SOME PIPING SHOWN OFFSET FOR CLARITY (TYP). 0 PROVIDE INDIRECT WASTE TO ADJACENT FR OR FD. REFERENCE ARCHITECTURAL DRAWINGS FOR SIZING INFORMATION. 0 PROVIDE CLEANOUT IN VENT PIPING. 0 CABINET HOUSING WATER HEATER; CUT OPENINGS IN CABINET TO ACCOMMODATE ALL PIPING AND ALLOW DRAINAGE TO FD -1. Q INSTALL GREASE INTERCEPTOR ABOVE FLOOR & BELOW 3—COMPARTMENT SINK. VERIFY & COORDINATE SIZE & LOCATION WITH 3— COMPARTMENT SINK & SINK LEGS. CUSTOM FABRICATED SINK LEG LOCATIONS MAY BE REQUIRED. RED IENNED O KE cope APPROVED *\ 70 It 01 Otv lbw RECEIVE? MAY - 9 2008 PERMIT CENTEI K 1 2 3 4 5 6 10 design group AMERICAN INSTITUTE OF ARCHITECTS I EXPIRES 8—I4 —O' HELIX DESIGN GROUP, INC HULTZ B1-11j-f C ROSS consulting engineers, Inc. 2407 North 31st Street Phone: (253) 383 -3257 general @hultzbhucross.com PLUMBING PLANS 7 AND DETAILS BEN & JERRY'S KIOSK 8 SOUTHCENTER MALL TUKWILLA , WA REVISION DATE 9 DATE JOB NO. 05.02.08 108 -043 PERMIT SET DRAWING NO. Tacoma, WA 98407 Fax (253) 383 -3283 Job Number: 08 -091 7 of 9 '' HELIX DESIGN GROUP, INC.: wl rights reserved.