HomeMy WebLinkAboutPermit PG08-153 - SABEY CORPORATION - BUILDING 2SABEY, BUILDING 2 3433 S 120 PL PGO8-153 Parcel No.: 1023049069 Address: Suite No: CitAf Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 3433 S 120 PL TUKW PLUMBING /GAS PIPING PERMIT Permit Number: Issue Date: Permit Expires On: PG08 -153 05/27/2008 11/23/2008 Tenant: Name: Address: SABEY, BUILDING 2 3433 S 120 PL , TUKWILA WA Owner: Name: SABEY CORPORATION Address: 12201 TUKWILA INTL BLVD 4THFL , SEATTLE WA Contact Person: Name: JESICA ROGERS Address: 1221 2 AV W , KENT WA Contractor: Name: HERMANSON COMPANY LLP Address: 1221 2ND AV N , KENT, WA Contractor License No: HERMACLOO5BJ Phone: Phone: 206 396 -0081 Phone: 206 -575 -9700 Expiration Date: 08/25/2008 DESCRIPTION OF WORK: RELOCATE (1) SHOWER AND INSTALL (1) NEW TOILET Value of Plumbing /Gas Piping: Fees Collected: $9,800.00 $130.00 Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 FIXTURE TYPE AND OUANTITY Plumbing (cont.) 1 Building sewer and each trailer park sewer 0 0 Rain water system - per drain (inside bldg) 0 0 Water heater and/or vent 0 0 Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 0 grease interceptors 0 0 Repair or alteration of water piping and/or water 0 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 1 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 0 0 Medical gas piping (6 +) inlets /outlets 0 0 Gas Piping 0 Gas piping outlets (0 -5) 0 0 Gas piping outlets (6 +) 0 * *continued on next page ** doc: UPC -10/06 PG08 -153 Printed: 05-27 -2008 City oliTukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: PG08 -153 Issue Date: 05/27/2008 Permit Expires On: 11/23/2008 Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied vllith, The grantin _ of t i s p�rmit construction •r th performan Signature: r, oes n eo Print Name: J Date: 7-3401 ed this permit and know the same to be true and correct. All provisions of law and ordinances hether specified herein or not. ot presume • • 've authority to violate or cancel the provisions of any other state or local laws regulating and obtain this plumbing /gas piping permit. Date: b.27 This permit shall become null and void if th work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from he last inspection. doc: UPC -10/06 PG08 -153 Printed: 05 -27 -2008 Parcel No.: Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 1023049069 3433 S 120 PL TUB:W SABEY, BUILDING 2 PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: PG08 -153 ISSUED 05/15/2008 05/27/2008 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted m the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. * *continued on next page ** doc: Cond -10/06 PG08 -153 Printed: 05 -27 -2008 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: Date: 2 U? doc: Cond -10/06 PG08 -153 Printed: 05 -27 -2008 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htip://www. ci. tukwilawaus Site Address: 1j Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** 12_./3"' PL Tenant Name: UI Oin 2 Property Owners Name: Ox Mailing Address: Name:, Mailing Address: King Co Assessor's Tax No.: Suite Number: New Tenant: ❑ Yes A..No Floor: Zip E -Mail Address: lay Telephone: %-' a Number: Zj Company Name: Mailing Address: Contact Person: E -Mail Address: Contractor Registration Nu City Day Telephone: Fax Number: Expiration Date: Company Name: Mailing Address: Zip Contact Person: E -Mail Address: City Day Telephone: Fax Number: State Company Name: Mailing Address: Contact Person: E -Mail Address: Q:\ApplicationslFomis- Applications On Line \3 -2006 - Permit Application.doc Revised; 9 -2006 bh City Day Telephone: Fax Number: State Zip Page 1 of 6 LU1VNO' PERMIT INFORM 4TION PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: Contact Person: _ % Ili E -Mail Address: Ett. Man• Contractor Registration Num'r: �►tr[i�t�'` c•"'�:�) City SA4,1,11111,111 Day Telephone:gal '11131-0U-15, i Expiration Date: Valuation of Plumbing work (contractor's bid price): $`-'1 �.1� Valuation of Gas Piping work (contractor's bid price): $ / Scope of Work (please .rovide detailed information): it l Building Use (per Int'l Building Code): 'Nu &$& *Vs Occupancy (per Int'l Buildin• Coo e): ■IN 0. 0 Utility Purveyor: Water: _ 6 WOIGI]ii, Sewer: \M V \)t %)3 tr 1 Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type; Qty; Fixture Type: Qty Fixture Type• , Qty Fixture Type: Qty Bathtub or combination bath /shower 1 Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain Sinks Dental unit, cuspidor Shower, single head trap 1 Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Additional medical gas inlets /outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets /outlets for specific gas Q:\Applications \Pones- Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 bh Page 5 of 6 T APP .,ICATION NOTES — Applkable t Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDIN OWNER OR A Signature: Mailing Address: State Date Application Accepted: 6 -cI rC ill Date Application Expires: ( l 6 [s ! n Staff Initials: �� Q:\Applications \Forms- Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 bh Page 6 of 6 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 1023049069 Address: 3433 S 120 PL TUKW Suite No: Applicant: SABEY, BUILDING 2 RECEIPT Permit Number: PG08 -153 Status: PENDING Applied Date: 05/15/2008 Issue Date: Receipt No.: R08 -01653 Payment Amount: $130.00 Initials: JEM Payment Date: 05/15/2008 10:37 AM User ID: 1165 Balance: $0.00 Payee: HERMANSON COMPANY LLP T1iANSACTION LIST: Type Method Descriptio Amount Payment Check 10657 130.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES PLUMBING - NONRES 000/345.830 26.00 000.322.103.00.0 104.00 Total: $130.00 2490 05/16 9710 TOTAL 130.00 rinr.• Raraint -OR Printad OS- 15 -20(1R INSPE ON NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit PERMIT NO. (206)431 -3 Project: y 5 `e- rim.. , Type of ectio : � .17. pi Address: : 34313 . tk (7.6 14-- Date Called: Specia Instructions: Date Wanted: Ce J _ _r !m: cJ� Requester: Phone 2061 S /ri U Approved per applicable codes. Corrections required prior to approval. COMMENTS: per Jk1f ( f ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION IL 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)43 1 -3670 P608 -/53 Projec ;. Type of Inspection: , Address: 3-433 Sol.. a� I•?) it Date Called. / Special Instructions: 3u . d-.4 1 . �. Date Wanted:�a 5- mr� 30- v} p.m. Requester: Phone No:(, "' /o �� Z c, Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector, Date - (3s„, 0 $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: p6e4g-ts� INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ILI 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Pr •; t: J. Si AI ( Type of Ins. ction: . lib , 41..(1a�._.�. r` Ad:r ss: ? 5 i O PL--- •ate Called: �1 f®t Jv (4-nf Specia Instructions: / Date Wanted: —2.0 ` 08. p.m. Requester: Phone N : 7 /Y� (0-72 Z.� Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspecto Date:_ 2 C � ❑ $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: • PERMIT COORD COPY. PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG08 -153 PROJECT NAME: SABEY, BUILDING 2 SITE ADDRESS: 3433 S 120 PL DATE: 05 -15 -08 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Buil ing ivision Public Works n Fire Prevention Structural n n Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 05-20-08 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route REVIEWER'S INITIALS: Structural Review Required n No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 06-17-08 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28-02 Look Up a Contractor, Electrin or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. License Information License HERMACLOO5BJ Licensee Name HERMANSON COMPANY LLP Licensee Type CONSTRUCTION CONTRACTOR UBI 602004844 Ind. Ins. Account Id PARTNER/MEMBER Business Type LIMITED LIABILITY COMPANY Address 1 1221 2ND AVE N Address 2 City KENT County KING State WA Zip 980322945 Phone 2065759700 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 1/11/2000 Expiration Date 8/25/2008 Suspend Date Separation Date Parent Company Previous License HERMAC *217NT Next License Associated License Business Owner Information Name Role Effective Date Expiration Date HERMANSON, RICHARD L PARTNER/MEMBER 01/01/1980 ALMON, KEVIN PARTNER/MEMBER 01/01/1980 MACDONALD, JAMES PARTNER/MEMBER 01/01/1980 • Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= HERMACL005BJ 05/27/2008 DUCT INSULATION (R-- -VALUE) LAST UPDATED: 01 /17/07 DUCT TYPE DUCT LOCATION N -R INSULATION R -VALUE RESID. INSULATION R- -VALUE REMARKS SUPPLY, RETURN NOT WITHIN CONDITIONED SPACE: ON EXTERIOR OF BUILDING, ON ROOF, IN ATTIC, IN ENCLOSED CEILING SPACE, IN WALLS, IN GARAGE, IN CRAWL SPACES R -7 R -8 1,2,3 OUTSIDE AIR INTAKE WITHIN CONDITIONED SPACE VARIES R -8 1,2,4,5 SUPPLY, RETURN, OUTSIDE AIR INTAKE NOT WITHIN CONDITIONED SPACE: IN CONCRETE, IN GROUND R -5.3 R -5.0 1,2 SUPPLY WITH <55° OR >105° AIR TEMPERATURE WITHIN CONDITIONED SPACE R -3.3 NOT REQ. 1,2 PIPE INSULATION (INCHES) LAST UPDATED: 01/17/07 SERVICE FLUID TEMP °F INSULATION CONDUCTIVITY NOMINAL PIPE DIAMETER (IN) CONDUCTIVITY RANGE MEAN TEMP RATING °F RUN -OUTS UP TO 2 1 & LESS >1 TO 2 >2 TO 4 >4 TO 6 >6 HWS &R 141 -200 0.25 -0.29 125 0.5 1.5 1.5 1.5 1.5 1.5 HWS &R 105-140 0.24 -0.28 100 0.5 1.0 1.0 1.0 1.5 1.5 CHWS &R 40 -45 0.23 -0.27 75 0.5 0.5 0.75 1.0 1.0 1.0 CHWS &R <40 0.23 -0.27 75 1.0 1.0 1.5 1.5 1.5 1.5 CDWS &R 40 -45 0.23-0.27 75 0.5 0.5 0.75 1.0 1.5 1.0 A AC ACH ACT AD ADD'L AFF AFG AHU ALUM AMP /AMPS AP ARCH BC BDD BF BHP BLDG BOD BOP BOT BS BTU BTU H CAP CC CD CDWR CDWS CFM CHWR CHWS CLG COL CONC COND CONN CONT CONTR COORD COP CT CU CW DB DBA DDC DEFL DEG DC DIA DMPR DN DT DWG EXH EA EAT EC EER EF EFF EL ELEC /ELECT EP EMCS ENT EQUIP ESP EWT EXIST F FAC ED FDC FF FIC FIO FLA FLEX FLR FOB FOIC FOS FOT FP FPM FSD FT FUT FV G GA GALV GC GEN GPM GR GRD GWB HD HORIZ HP HR HSPF HT HWTG HWR HWS HX MECHANICAL ABBREVIATIONS AMPS AIR CONDITIONING AIR CHANGES PER HOUR ACOUSTICAL TILE CEILING ACCESS DOOR ADDITIONAL ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AIR HANDLING UNIT ALUMINUM AMPERAGE ACCESS PANEL ARCHITECT BEADED COLLAR BACKDRAFT DAMPER BELOW FLOOR BRAKE HORSEPOWER BUILDING BOTTOM OF DUCT BOTTOM OF PIPE BOTTOM BIRD SCREEN BRITISH THERMAL UNIT BRITISH THERMAL UNITS PER HOUR CAPACITY CONTROLS CONTRACTOR CEILING DIFFUSER /CONDENSATE DRAIN CONDENSER WATER RETURN CONDENSER WATER SUPPLY CUBIC FEET PER MINUTE CHILLED WATER RETURN CHILLED WATER SUPPLY CEILING COLUMN CONCRETE CONDENSATE CONNECT /CONNECTED /CONNECTION CONTINUOUS /CONTINUATION CONTRACTOR COORDINATE COEFFICIENT OF PERFORMANCE COOLING TOWER CUBIC /CONDENSER UNIT DOMESTIC COLD WATER /CONDENSER WATER DUCTBOARD /DRY BULB DECIBEL DIRECT DIGITAL CONTROL DEFLECTION DEGREE/ DEGREES MODULAR DIFFUSER (GWB CEILING) DIAMETER DAMPER DOWN MODULAR DIFFUSER ( "T -BAR" CEILING) DRAWING EXHAUST EACH ENTERING AIR TEMPERATURE EGGCRATE GRILLE /END CAP /ELEC CONTRACTOR ENERGY EFFICIENT RATING EXHAUST FAN EFFICIENCY ELEVATION ELECTRICAL /ELECTRIC END PLUG ENERGY MANAGEMENT CONTROL SYSTEM ENTERING EQUIPMENT EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXISTING FAHRENHEIT FIRE ALARM CONTRACTOR FIRE DAMPER FIRE DEPARTMENT CONNECTION FINISHED FLOOR FURNISHED AND INSTALLED BY CONTRACTOR FURNISHED AND INSTALLED BY OWNER FULL LOAD AMPS FLEXIBLE FLOOR FLAT ON BOTTOM FURNISHED BY OTHERS. INSTALLED BY CONTRACTOR FLAT ON SIDE FLAT ON TOP FIRE PROTECTION FEET PER MINUTE FIRE /SMOKE DAMPER FOOT /FEET FUTURE FACE VELOCITY GRILLE GAUGE /GALLON GALVANIZED GENERAL CONTRACTOR GENERAL GALLONS PER MINUTE GRILLE GRILLE /REGISTER /DIFFUSER GYPSUM WALL BOARD HEAD HORIZONTAL HORSEPOWER HOUR HEATING SEASONAL PERFORMANCE FACTOR HEIGHT HIGH WALL TRANSFER GRILLE HOT WATER RETURN HOT WATER SUPPLY HEAT EXCHANGER HZ BC CW D E MC N N WG PLV KW HERTZ NTERNATIONAL BUILDING CODE NDUSTRIAL COLD WATER NSIDE DIAMETER /DIMENSION NVERT ELEVATION NTERNATIONAL MECHANICAL CODE NCHES NCHES WATER GAUGE NTEGRATED PART LOAD VALUE KILOWATTS LAT LEAVING AIR TEMPERATURE LB /LBS POUND /POUNDS LD /LIN DIFF LINEAR DIFFUSER LF /LIN FT LINEAL FOOT /FEET LPG LIQUID PROPANE GAS LVG LEAVING LWA SOUND POWER LWG LOW WALL GRILLE LWR LOW WALL REGISTER LWT LEAVING: WATER TEMPERATURE MAX MAXIMUM MAU MAKE UP. AIR UNIT MBH 1000 'BRITISH THERMAL UNITS MCA MINIM Up CIRCUIT AMPACITY MD MOTORED DAMPER MFR MANUFACTURER MISC MISCELLANEOUS MIN MINIMUM /MINUTE MT MOUNT MTD MOUNTED MUW MAKE -UP WATER N/A NOT APPLICABLE NC NORMALLY CLOSED /NOISE CRITERIA NG /NGAS NATURAL GAS NIC NOT IN CONTRACT NO NORMALLY OPEN /NUMBER NPW NON- POTABLE WATER N -R NON-RESIDENTIAL OA /OSA OUTSIDE AIR OB OPPOSED BLADE OBD OPPOSED BLADE DAMPER OD OUTSIDE DIAMETER /DIMENSION P PUMP PCF POUNDS PER CUBIC FOOT PD PRESSURE DROP PH PHASE POC POINT OF CONNECTION PRESS PRESSURE PSI POUNDS PER SQUARE INCH PSIG POUNDS PER SQUARE INCH GAUGE QTY QUANITY R RETURN GRILLE /RELOCATED /RETURN RA RETURN AIR RD /RND ROUND REF REFERENCE REG REGISTER REQ REQUIRED RESID RESIDENTIAL RF RELIEF RG RETURN GRILLE RL REFRIGERANT LIQUID RPM REVOLUTIONS PER MINUTE RS REFRIGERANT SUCTION S SUPPLY SA SUPPLY AIR SAT SATURATION SD SMOKE DETECTOR S/D SLIP & DRIVE CONNECTION SEER SEASONAL ENERGY EFFICIENCY RATING SENS SENSIBLE SG SUPPLY GRILLE SL SOUND LINED SM SPIRALMATE /SHEETMETAL SPEC SPECIFICATION SO SCREENED OPENING SOG SLAB ON GRADE SP STATIC PRESSURE SQ FT SQUARE FEET SR SIDE WALL REGISTER SS STAINLESS STEEL STRUC STRUCTURAL T TRANSFER TA TRANSFER AIR TEMP TEMPERATURE /TEMPORARY TBD TO BE DETERMINED TG TRANSFER GRILLE TOC TOP OF CONCRETE /CURB TOD TOP OF DUCT TOS TOP OF STEEL /TOP OF SLAB TOT TOTAL TSP TOTAL STATIC PRESSURE TSTAT THERMOSTAT TYP TYPICAL UH UNIT HEATER UNO UNLESS NOTED OTHERWISE V VOLT . VIAQC VEIJT..AND INDOOR AIR QUALITY CODE VD VOLUME DAMPER VEL VELOCITY VERT VERTICAL VFD VARIABLE FREQUENCY DRIVE VOL VOLUME W WALL /WALLS, WRAPPED DUCT WB WET BULB WG WATER GAUGE W/ WITH W/0 WITHOUT W /SF WATTS PER SQUARE FOOT WSEC WASHINGTON STATE ENERGY CODE MECHANICAL LEGEND 10x10 10x i10xlo ;;X, : 10x10 1 10x10 : 10x10 Ei J - 1 Ox 1 0 ;,/1 1Ox • 1 00 1 0 I DUCT OVERLAP t 100 T_ 45° TAP 10 VOLUME DAMPER »:iE ,rwvv vv MOM . t16x16SL � 16x16DB z • CHWS • CHWR 9 CD1 -100 80 SP k k �I C�1 t="j‘rv%tT 0 CD 40 CHWS CHWR 2- RL 5 .- Rs -5 2 NG -5 CDWS CDWS -5 • CDWR CDWR -5 z ----�- Hws 1 2- HWR S 2- COND COND -5 RECTANGULAR SUPPLY AIR DUCT - TURNING UP OR TOWARD RECTANGULAR SUPPLY AIR DUCT - TURNING DOWN OR AWAY RECTANGULAR EXHAUST OR RETURN AIR DUCT - TURNING UP OR TOWARD RECTANGULAR EXHAUST OR RETURN AIR DUCT - TURNING DOWN OR AWAY ROUND DUCT - ROUND DUCT - FLATOVAL DUCT FLATOVAL DUCT BOOT TAP CHANGE OF ELEVATION RISE(R) DROP(D) TRANSITION TURNING VANES /SPUTTERS DUCT MOUNTED SMOKE DETECTOR BACK DRAFT DAMPER FLEXIBLE DUCT AIR FLOW DIRECTION FORCED AIR) AIR FLOW DIRECTION DRAWN AIR) MOTOR OPERATED DAMPER FLEX CONNECTION SMOKE DAMPER FIRE DAMPER COMBINATION FIRE & SMOKE DAMPER SOUND TRAP ACCESS DOORS TURNING UP OR TOWARD TURNING DOWN OR AWAY - TURNING UP OR TOWARD - TURNING DOWN OR AWAY ACOUSTICALLY LINED DUCT (SOUND LINED) DUCT BOARD FABRIC DUCT VAV BOX CEILING SUPPLY AIR DIFFUSER (SHOWN WITH REDIRECTED AIR CORE) CEILING RETURN, TRANSFER OR EXHAUST AIR GRILLE SLOTTED DIFFUSER (PLAN VIEW) REVISION CLOUD & TRIANGLE ROUND DUCT SYMBOL FLATOVAL DUCT SYMBOL DEGREES SYMBOL POINT OF CONNECTION GRD TAG IDENTIFIER = TYPE -CFM SIZE THERMOSTAT /TEMPERATURE SENSOR HUMIDITY SENSOR SMOKE DETECTOR STATIC PRESSURE SENSOR EXISTING DUCTWORK DEMO DUCTWORK WALL - MOUNTED GRILLE o PIPE ELBOW UP PIPE ELBOW DN DIRECTION OF FLOW DIRECTION OF SLOPE PLUG OR CAP GAS PRESSURE REDUCING ASSEMBLY SOLENOID VALVE PUMP CHILLED WATER SUPPLY CHILLED WATER RETURN REFRIGERANT LIQUID REFRIGERANT SUCTION NATURAL GAS LIQUID PROPANE GAS CONDENSER WATER SUPPLY CONDENSER WATER RETURN HEATING WATER SUPPLY HEATING WATER RETURN CONDENSATE DOWN MECHANICAL GENERAL NOTES 1. ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO THE 2006 IBC, 2006 WSEC, 2006 IMC & 2006 WSVIAQC. 2. DIMENSIONS ARE TO FACE OF STUD, CONCRETE, OR MASONRY UNLESS NOTED OTHERWISE. 3. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN. 4. VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, DETAILS, ETC. NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. 5. WHEN CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. IF ADDITIONAL QUESTIONS REMAIN, CONTACT THE ENGINEER PRIOR TO PROCEEDING. 6. ALL STRUCTURAL OPENINGS AND PLATFORMS SHALL BE PROVIDED BY THE GENERAL CONTRACTOR UNLESS NOTED OTHERWISE. 7. DUCT SEALING AND CONSTRUCTION TO MEET SMACNA AND ENERGY CODE REQUIREMENTS. UNLESS OTHERWISE NOTED, LOW PRESSURE DUCTWORK (DOWNSTREAM OF VAV BOXES, CONSTANT VOLUME AC SYSTEMS, TOILET EXHAUSTS, ETC.) TO MEET 2" CONSTRUCTION STANDARDS WITH SEAL CLASS C. MEDIUM PRESSURE DUCTWORK (UPSTREAM OF VAV BOXES, HIGH VELOCITY EXHAUSTS, ETC.) TO MEET 4" CONSTRUCTION STANDARDS WITH SEAL CLASS A. DUCT RISERS IN SHAFTS WITH DAMPERED PENETRATIONS TO MEET 6" CONSTRUCTION STANDARDS WITH SEAL CLASS A. 8. ALL CEILING DIFFUSERS ARE 4 -WAY THROW UNLESS NOTED OTHERWISE. 9. ALL DUCT DIMENSIONS ARE CLEAR INSIDE DIMENSIONS AFTER LINING HAS BEEN INSTALLED. 10. OUTSIDE AIR INTAKES ON ALL AIR HANDLING UNITS SHALL BE 10 FEET AWAY FROM ANY FUEL BURNING EQUIPMENT, AND 10 FEET AWAY FROM, OR 3 FEET BELOW ANY PLUMBING VENT OR EXHAUST OUTLET. 11. ALL AIR ECONIMIZERS SHALL BE CAPABLE OR THE FOLLOWING: . - 0% TO 100% OF THE DESIGN SUPPLY AIR - CONTROLLED BY A CONTROL SYSTEM DETERMINING IF THE OUTSIDE AIR CAN MEET PART OR ALL OF THE BUILDING COOLING LOADS. - INTEGRATED TO PROVIDE PARTIAL COOLING EVEN WHEN MECHANICAL COOLING IS REQUIRED. 12. OUTSIDE AIR INTAKE, RELIEF, AND EXHAUST OPENINGS SHALL BE EQUIPPED WITH MOTORIZED OR GRAVITY DAMPERS WHICH CLOSE AUTOMATICALLY WHEN SYSTEM IS OFF OR UPON POWER FAILURE, AS REQUIRED BY ENERGY CODE. 13. THE CONTROL SYSTEM SHALL BE 7-DAY PROGRAMABLE, CAPABLE OF BEING SET FOR SEVEN (7) DIFFERENT DAY TYPES PER WEEK, AND CAPABLE OF A DEADBAND SETTING OF AT LEAST 5 DEGREES F 10 °F FOR RESIDENTIAL) BETWEEN THE HEATING AND COOLING SETPOINTS. AHU CONTROL SYSTEM SHALL INCLUDE A MICROPROCESSOR AND BE CAPABLE OF RESETTING SUPPLY AIR TEMPERATURES BY REPRESENTATIVE BUILDING LOADS. 14. RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER THE WASHINGTON STATE ENERGY CODE. AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER. ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCING REPORT SHALL BE PROVIDED TO THE OWNER. HVAC CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORDANCE WITH SPECIFICATIONS AND APPROVED PLANS. A PRELIMINARY COMMISIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY. A COMPLETE FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PROVIDED TO THE OWNER. COMMISIONING, SYSTEM BALANCING, RECORD DRAWINGS AS REQUIRED PER THE WASHINGTON STATE ENERGY CODE. 15. MECHANICAL SYSTEMS SHALL COMPLY WITH SEISMIC RESTRAINT REQUIREMENTS OF THE BUILDING CODE, SMACNA AND ASCE 7. ALL LIFE SAFETY HAZARDOUS MATERIAL RELATED SYSTEMS SHALL BE DEEMED AN I10=1.5 FOR RESTRAINT METHODS OR AS NOTED ON THE DRAWINGS. REFER TO THE ABOVE NOTED CODES FOR INSTALLATION REQUIREMENTS AND EXCEPTIONS BASED ON SIZING, WEIGHTS AND MOUNTING HEIGHTS. 16. PROVIDE EARTHQUAKE RESTRAINTS FOR HVAC EQUIPMENT AS REQUIRED BY SMACNA SEISMIC RESTRAINT MANUAL, SEIZMIC HAZARD B. WIRES FOR CEILING SYSTEM ETC. SHALL NOT BE HUNG OFF HVAC EQUIPMENT OR HVAC EQUIPMENT SUPPORTS. 17. PROVIDE FIRE AND COMBINATION FIRE /SMOKE DAMPERS WHERE SHOWN ON PLANS AND WHERE REQUIRED PER CODE. 18. ALL PIPING PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE SEALED WITH AN UL APPROVED FIRE CAULKING. 19. SMOKE DETECTORS PROVIDING AUTOMATIC SHUTDOWN SHALL BE PROVIDED FOR HVAC EQUIPMENT DELIVERING IN EXCESS OF 2000 CFM [INCLUDING MULTIPLE UNITS DUCTED INTO COMMON DISTRIBUTION OR RETURN, WITH AN AGGREGATE SUPPLY GREATER THAN 2000 CFM1 OR EACH STORY OF RETURN SYSTEMS OVER 15.000 CFM IN A MULTI -STORY INSTALLATION, PER CODE. SMOKE DETECTORS SHALL BE FURNISHED AND NSTALLED BY ELECTRICAL CONTRACTOR UNLESS NOTED OTHERWISE. POWER- WIRING AND INTERLOCK TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR AS APPLICABLE. 20. ACCESS PANELS SHALL BE PROVIDED BY MECHANICAL CONTRACTOR AND INSTALLED BY GENERAL CONTRACTOR. 21. ALL MOTOR STARTERS NOT SHOWN IN EQUIPMENT SCHEDULES SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. 22: FOR ALL "SEALED AIR TIGHT" SHAFTS OR ROOMS, THE FOLLOWING SHALL OCCUR: -ALL VERTICAL JOINTS INSIDE THE SHAFT SHALL BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT, INCLUDING THE SHAFT CORNERS (BY GC) - TOP AND BOTTOM WALL TRACKS SHOULD BE CAULKED ALONG THEIR ENTIRE LENGTH (BY GC) - ANY FLOOR DECKING PERPENDICULAR TO THE SHAFT SHALL BE CAULKED (BY GC). FILLING WITH ROCK WOOL IS NOT ACCEPTABLE - ANY PENETRATIONS OF THE SHAFT CONSTRUCTION (DUCTWORK, CONDUIT, PIPING, ...) SHALL BE SEALED ON BOTH SIDES OF THE PENETRATION. - USE SECTION 905 OF THE 2003 IBC FOR MAXIMUM ALLOWABLE LEAKAGE AREA, FOLLOWING THE GUIDELINES FOR TIGHT STAIR SHAFT CONSTRUCTION. -ALL DOORS SHALL BE PROVIDED WITH TIGHT FITTING GASKETS, AND OPEN AGAINST THE DIRECTION OF ROOM /SHAFT PRESSURE. 23. MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL BE 12 FEET. REFER TO INSTALLATION DETAILS FOR SUPPORT REQUIREMENTS. FLEXIBLE DUCT FLAME SPREAD RATING SHALL BE < 25 AND SMOKE DEVELOPED RATING SHALL BE < 50. USE FLEXIDUCT MODEL G -KM FOR LOW AND MEDIUM PRESSURE APPLICATIONS OR APPROVED EQUAL. INSULATE DUCT PER NOTE 11 ABOVE. 24. LOCATION AND DETAILS OF EQUIPMENT, DUCT ROUTING, AND CONNECTIONS ARE APPROXIMATE. COORDINATE FINAL LOCATIONS WITH OTHER TRADES. INSTALL IN ACCORDANCE WITH APPROVED SUBMITTALS AND DETAIL DRAWINGS WHEN APPLICABLE. 25. FOR RESIDENTIAL INSULATION ON DUCTWORK AND PIPING SEE ENERGY CODE CHAPTER 5 AND TABLES 5 -11 AND 5 -12. 1. REFER TO ENERGY CODE SECTION 1414.2 FOR FURTHER REQUIREMENTS 2. REQUIREMENTS APPLY TO HEATED AND MECHANICALLY COOLED DUCT SYSTEMS AS NOTED. INSULATED COOLED DUCTS REQUIRED A VAPOR RETARDER (PERM < 0.5 ) AND SEALED JOINTS. 3. WEATHERPROOF BARRIER REQUIRED AROUND DUCTWORK TO MAINTAIN WATER TIGHTNESS. 4. INSULATE OUTSIDE AIR DUCTS TO BUILDING ENVELOPE LEVEL PER ENERGY CODE CHAPTER 13 UNTIL CONNECTED TO EQUIPMENT SERVED OR TO THE CODE REQUIRED SHUTOFF DAMPER (THEN R -7 FOR REST Of INSTALLATION ). 5. R -7 CAN BE USED IN LIEU OF BUILDING ENVELOPE INSULATION LEVEL IF: DEDICATED OUTSIDE AIR SYSTEM AND LESS THAN 2,800 CFM. -S CONDENSER WATER (FOR NON-ECONOMIZER SYSTEMS - INSULATION IS NOT REQUIRED) DRAWING INDEX SHEET NO. P -A -01 P -E -11 P - I - 01 SHEET TITLE LEGEND, ABBREVIATIONS, GENERAL NOTES, & SHEET INDEX - PLUMBING FIRST FLOOR PLAN - PLUMBING SCHEDULES SHEET - PLUMBING APN NUMBER 1023049069 LEGAL DESCRIPTION PORTION OF GOV LOT 15 IN SW 1/4 OF SECTION 10 -23 -04 BEGIN NW CORNER OF SW 1/4 TH S 01 -46 -02 W 107,22 FT TH S 87 -33 -12 E 512.24 FT TO POINT OF BEGINNING TH S 87 -33 -12 E 214.16 FT TH N 78 -40 -52 E 415.05 FT TO WLY MARGIN OF E MARGINAL WAY TH S 16 -31 -41 E 241.92 FT TH S 28 -02 -57 E 104.42 FT TH S 17 -01 -47 E 100.50 FT TH S 11 -19 -15 E 13.28 FT TH N 58-13-58 W 473,87 FT TH S 01 -46 -02 W 37 FT TH N 8a:--13-58 W 307.80 FT TH N 01 -46 -02 E 373.93 FT TO POINT OF BEGINNING - LOT 1 OF CITY OF TUKWILA BOUNDARY LINE ADJUSTMENT NO,L2000 -042 RECORDING NO 20000828900001 '. ;s; 1 VICINITY MAP NO SCALE SITE MAP NO SCALE FILE COPY Permit No. City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan rev2w fe=es Plar review approval Is subject to errors and omissions. Approval of construction documents does not authorize the violation of any = t � � • v • e or ordinance. Receipt of approv= i 3Id Cop • .con l , . . r` is aura ► : ed�:ed: By i.4.21■ _'<-2-77,* 0-11 -�� Date: ' - 1 EWEWED ®R DE COMPLIANCE AP ROVE' MAY 2 2 2008 tv of T SEPARATE PERMIT REQUIRED FOR: v/ Mechanical [Electrical ❑ Plumbing ❑ Gas Piping City of Tukwila I BUILDING DIVISION i RECEIVED CITY OF TUKWILA MAY 15 2008 PERMIT CENTER Hermanson Micioso ft TUKWILA 2 BUILDING CD SET 3433 SOUTH 120TH PL TUKWILA, WA 98168 Design Drawn Checked Date HERMANSON Project No. M.S. Project No. No. Date Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575 -9700 Fax: (206) 575 -9800 www.hermanson.com Contractor Reg #: HERMACLOO5BJ Design Team Revisions Description 5/14/2008 CD SET Registration EXPIRES 1/29/ 1 Key Plan Bar Code Sheet Title /Number P-A-01 MG ER DN 5/14/2008 11-8-0286 P.11170 LEGEND, ABBREVIATIONS, GENERAL NOTES, & SHEET INDEX - PLUMBING 4 II = L 4 ( SCALE: 1/8" = FIRST FLOOR PLAN - PLUMBING _ 1 il II II 11 11 p ssizaziN es itima le4se• p 0.344,L REVIEWED FOR \ 70E COMPLIANCE APPROVED MAY 2 2, 20q8 Citv Of Tukw BUILDINciDlyl..c.:-103_1_ _ C140F41 MAY "I 5 2008 PERMIT CENTER Design Drawn Checked Date M.S. Project No. No. Date Hermanson Hermanson Company LLP 1221 2nd Avenue North Kent Washington 98032 Tei: (206) 575-9700 Fax: (206) 575-9800 www. hermanson. corn Contractor Reg #: HERMACL005BJ TUKWILA 2 BUILDING CD SET 3433 SOUTH 120TH PL TUKWILA, WA 98168 HERMANSON Project No. Design Team Revisions Description 5/14/2008 CD SET Registration I EXPIRES 1 /29/ I J Key Plan Bar Code Sheet Title/Number FIRST FLOOR PLAN -PLUMBING P-E-11 MG ER ON 5/14/2008 11-8-0286 P.11170 • '...••• - PLUMBING FIXTURE SCHEDULE LAST UPDATED 5/14/08 SYMBOL DESCRIPTION MANUFACTURER AND MODEL NUMBER HW CW W V REMARKS LAV -1 LAVATORY MATCH EXISTING 1/2" 1/2" 2" 1 -1/2" 2 SH -1 SHOWER MATCH EXISTING 1/2" 1/2" 2" 1 -1/2" 2 WC-1 WATER CLOSET MATCH EXISTING - 1 "* 4" 2" 2 U -1 URINAL MATCH EXISTING - 3/4" 2" 1 -1/2" 2 NOTES: SIZE CW AT 1 1/4" DOWN TO FIXTURE CONNECTION FOR ALL FLUSH VALVE WATER CLOSETS 1 PROVIDE JUST J -35 SS CUP STRAINER WITH REMOVABLE BASKET, 1 1/2 17 GA P -TRAP CHROME PLATE, BRASSCRAFT LOOSE -KEY LAV SUPPLY KIT CHROME PLATED WITH BRAIDED FLEXIBLE HOSE. 2 WATER SERVICE & SHUT OFF BY PLUMBING CONTRACTOR 3 DISHWASHER PROVIDED BY OTHERS. CONNECT DRAIN TO SINK TAILPIECE WITH DRAIN AND WATER SERVICE & SHUT OFF BY PLUMBING CONTRACTOR. AT SINK PROVIDE WITH EASTMAN AIRGAP FITTING 4 POLYSTYRENE OR METAL BOX WITH QUARTER TURN STOP SHUTOFF. (nHr3 C fi }DE COMPLxp APPROV f.,.. �, � ? k1 MAY 2 J� play '�. 'zy tv, 1r- RECEIVED CITY OF TUKWILA MAY 15 2008 PERMIT CENTER Hermanson 3433 SOUTH 120TH PL TUKWILA, WA 98168 Design Drawn Checked Dote HERMANSON Project No. M.S. Project No. No. Date Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575 -9700 Fax: (206) 575 -9800 www.hermanson.com Contractor Reg #: HERMACL005BJ TUKWILA 2 BUILDING CD SET Design Team Revisions Description 5/14/2008 CD SET Registration I EXPIRES 1/29/ I° 1 5/14/2008 1 1 -8 -0286 P.11170 Key Plan Bar Code Sheet Title /Number SCHEDULES SHEET - PLUMBING P-.I-o1 MG ER DN