HomeMy WebLinkAboutPermit PG08-153 - SABEY CORPORATION - BUILDING 2SABEY, BUILDING 2
3433 S 120 PL
PGO8-153
Parcel No.: 1023049069
Address:
Suite No:
CitAf Tukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
3433 S 120 PL TUKW
PLUMBING /GAS PIPING PERMIT
Permit Number:
Issue Date:
Permit Expires On:
PG08 -153
05/27/2008
11/23/2008
Tenant:
Name:
Address:
SABEY, BUILDING 2
3433 S 120 PL , TUKWILA WA
Owner:
Name: SABEY CORPORATION
Address: 12201 TUKWILA INTL BLVD 4THFL , SEATTLE WA
Contact Person:
Name: JESICA ROGERS
Address: 1221 2 AV W , KENT WA
Contractor:
Name: HERMANSON COMPANY LLP
Address: 1221 2ND AV N , KENT, WA
Contractor License No: HERMACLOO5BJ
Phone:
Phone: 206 396 -0081
Phone: 206 -575 -9700
Expiration Date: 08/25/2008
DESCRIPTION OF WORK:
RELOCATE (1) SHOWER AND INSTALL (1) NEW TOILET
Value of Plumbing /Gas Piping:
Fees Collected:
$9,800.00
$130.00
Plumbing
Bathtub or combination bath/shower
Bidet
Clothes washer, domestic
Dental unit, cuspidor
Dishwasher, domestic, with independent drain
Drinking fountain or water cooler (per head)
Food -waste grinder, commercial
Floor drain
Shower, single head trap
Lavatory
Wash fountain
Receptor, indirect waste
Sinks
Urinals
Water Closet
Uniform Plumbing Code Edition: 2006
International Fuel Gas Code Edition: 2006
FIXTURE TYPE AND OUANTITY
Plumbing (cont.)
1 Building sewer and each trailer park sewer 0
0 Rain water system - per drain (inside bldg) 0
0 Water heater and/or vent 0
0 Industrial waste treatment interceptor, including
0 its trap and vent, except for kitchen type
0 grease interceptors 0
0 Repair or alteration of water piping and/or water
0 treatment equipment 0
0 Repair or alteration of drainage or vent piping 0
1 Medical gas piping system serving (1 -5)
0 inlets /outlets for a specific gas 0
0 Medical gas piping (6 +) inlets /outlets 0
0 Gas Piping
0 Gas piping outlets (0 -5) 0
0 Gas piping outlets (6 +) 0
* *continued on next page **
doc: UPC -10/06
PG08 -153 Printed: 05-27 -2008
City oliTukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Permit Number: PG08 -153
Issue Date: 05/27/2008
Permit Expires On: 11/23/2008
Permit Center Authorized Signature:
I hereby certify that I have read and e
governing this work will be complied vllith,
The grantin _ of t i s p�rmit
construction •r th performan
Signature: r,
oes n
eo
Print Name:
J
Date: 7-3401
ed this permit and know the same to be true and correct. All provisions of law and ordinances
hether specified herein or not.
ot presume • •
've authority to violate or cancel the provisions of any other state or local laws regulating
and obtain this plumbing /gas piping permit.
Date: b.27
This permit shall become null and void if th work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from he last inspection.
doc: UPC -10/06
PG08 -153 Printed: 05 -27 -2008
Parcel No.:
Address:
Suite No:
Tenant:
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
1023049069
3433 S 120 PL TUB:W
SABEY, BUILDING 2
PERMIT CONDITIONS
Permit Number:
Status:
Applied Date:
Issue Date:
PG08 -153
ISSUED
05/15/2008
05/27/2008
1: ** *PLUMBING AND GAS PIPING * **
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila
Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing
inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas
Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code.
Tests shall be conducted m the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to
make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless,
adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the
conditioned space shall be insulated to minimum R -3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be
protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing
piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in
accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to
twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill,
frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the
jurisdiction.
* *continued on next page **
doc: Cond -10/06
PG08 -153 Printed: 05 -27 -2008
•
City of Tukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating
construction or the performance of work.
Signature:
Print Name:
Date: 2 U?
doc: Cond -10/06
PG08 -153 Printed: 05 -27 -2008
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
htip://www. ci. tukwilawaus
Site Address: 1j
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
12_./3"' PL
Tenant Name: UI Oin 2
Property Owners Name: Ox
Mailing Address:
Name:,
Mailing Address:
King Co Assessor's Tax No.:
Suite Number:
New Tenant: ❑ Yes A..No
Floor:
Zip
E -Mail Address:
lay Telephone:
%-'
a Number: Zj
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
Contractor Registration Nu
City
Day Telephone:
Fax Number:
Expiration Date:
Company Name:
Mailing Address:
Zip
Contact Person:
E -Mail Address:
City
Day Telephone:
Fax Number:
State
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
Q:\ApplicationslFomis- Applications On Line \3 -2006 - Permit Application.doc
Revised; 9 -2006
bh
City
Day Telephone:
Fax Number:
State
Zip
Page 1 of 6
LU1VNO'
PERMIT INFORM 4TION
PLUMBING AND GAS PIPING CONTRACTOR INFORMATION
Company Name:
Mailing Address:
Contact Person: _
% Ili
E -Mail Address: Ett. Man•
Contractor Registration Num'r: �►tr[i�t�'` c•"'�:�)
City SA4,1,11111,111
Day Telephone:gal '11131-0U-15, i
Expiration Date:
Valuation of Plumbing work (contractor's bid price): $`-'1 �.1�
Valuation of Gas Piping work (contractor's bid price): $ /
Scope of Work (please .rovide detailed information):
it l
Building Use (per Int'l Building Code): 'Nu &$& *Vs
Occupancy (per Int'l Buildin• Coo e): ■IN 0. 0
Utility Purveyor: Water: _ 6 WOIGI]ii,
Sewer: \M V \)t %)3 tr 1
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
Fixture Type;
Qty;
Fixture Type:
Qty
Fixture Type• ,
Qty
Fixture Type:
Qty
Bathtub or combination
bath /shower
1
Drinking fountain or water
cooler (per head)
Wash fountain
Gas piping outlets
Bidet
Food -waste grinder,
commercial
Receptor, indirect
waste
Clothes washer, domestic
Floor drain
Sinks
Dental unit, cuspidor
Shower, single head trap
1
Urinals
Dishwasher, domestic,
with independent drain
Lavatory
Water Closet
Building sewer or trailer
park sewer
Rain water system — per
drain (inside building)
Water heater and/or
vent
Additional medical gas
inlets /outlets — six or more
Industrial waste
pretreatment interceptor,
including its trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of water
piping and/or water treating
equipment
Repair or alteration
of drainage or vent
piping
Medical gas piping system
serving one to five
inlets /outlets for specific gas
Q:\Applications \Pones- Applications On Line \3 -2006 - Permit Application.doc
Revised: 9 -2006
bh
Page 5 of 6
T APP .,ICATION NOTES — Applkable t
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDIN OWNER OR A
Signature:
Mailing Address:
State
Date Application Accepted:
6 -cI rC ill
Date Application Expires:
( l 6 [s ! n
Staff Initials: ��
Q:\Applications \Forms- Applications On Line \3 -2006 - Permit Application.doc
Revised: 9 -2006
bh
Page 6 of 6
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http://www.ci.tukwila.wa.us
Parcel No.: 1023049069
Address: 3433 S 120 PL TUKW
Suite No:
Applicant: SABEY, BUILDING 2
RECEIPT
Permit Number: PG08 -153
Status: PENDING
Applied Date: 05/15/2008
Issue Date:
Receipt No.: R08 -01653
Payment Amount: $130.00
Initials: JEM Payment Date: 05/15/2008 10:37 AM
User ID: 1165 Balance: $0.00
Payee: HERMANSON COMPANY LLP
T1iANSACTION LIST:
Type Method Descriptio Amount
Payment Check 10657 130.00
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
PLAN CHECK - NONRES
PLUMBING - NONRES
000/345.830 26.00
000.322.103.00.0 104.00
Total: $130.00
2490 05/16 9710 TOTAL 130.00
rinr.• Raraint -OR
Printad OS- 15 -20(1R
INSPE ON NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
(206)431 -3
Project:
y 5 `e- rim..
, Type of ectio :
� .17.
pi
Address: :
34313 . tk (7.6 14--
Date Called:
Specia Instructions:
Date Wanted:
Ce J _ _r !m:
cJ�
Requester:
Phone
2061 S /ri U
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
per Jk1f (
f
❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION IL
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)43 1 -3670
P608 -/53
Projec ;.
Type of Inspection:
,
Address:
3-433 Sol..
a�
I•?) it
Date Called.
/
Special Instructions:
3u . d-.4 1
.
�.
Date Wanted:�a
5-
mr�
30- v} p.m.
Requester:
Phone No:(,
"'
/o �� Z c,
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
Inspector,
Date - (3s„,
0 $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection.
Receipt No.:
Date:
p6e4g-ts�
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION ILI
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Pr •; t:
J.
Si AI
(
Type of Ins. ction: . lib ,
41..(1a�._.�. r`
Ad:r ss:
?
5
i O PL---
•ate Called: �1
f®t Jv (4-nf
Specia Instructions:
/
Date Wanted:
—2.0 ` 08. p.m.
Requester:
Phone N :
7 /Y� (0-72 Z.�
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
Inspecto
Date:_ 2 C
�
❑ $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection.
Receipt No.:
Date:
• PERMIT COORD COPY.
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: PG08 -153
PROJECT NAME: SABEY, BUILDING 2
SITE ADDRESS: 3433 S 120 PL
DATE: 05 -15 -08
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # After Permit Issued
DEPARTMENTS:
Buil ing ivision
Public Works
n
Fire Prevention
Structural
n
n
Planning Division
Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
Incomplete n
DUE DATE: 05-20-08
Not Applicable n
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROUTING:
Please Route
REVIEWER'S INITIALS:
Structural Review Required n No further Review Required
DATE:
APPROVALS OR CORRECTIONS:
Approved Approved with Conditions
Notation:
REVIEWER'S INITIALS:
DUE DATE: 06-17-08
Not Approved (attach comments)
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28-02
Look Up a Contractor, Electrin or Plumber License Detail
Washington State Department of Labor and Industries
General/Specialty Contractor
A business registered as a construction contractor with L &I to perform
construction work within the scope of its specialty. A General or Specialty
construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
License Information
License
HERMACLOO5BJ
Licensee Name
HERMANSON COMPANY LLP
Licensee Type
CONSTRUCTION CONTRACTOR
UBI
602004844
Ind. Ins. Account Id
PARTNER/MEMBER
Business Type
LIMITED LIABILITY COMPANY
Address 1
1221 2ND AVE N
Address 2
City
KENT
County
KING
State
WA
Zip
980322945
Phone
2065759700
Status
ACTIVE
Specialty 1
GENERAL
Specialty 2
UNUSED
Effective Date
1/11/2000
Expiration Date
8/25/2008
Suspend Date
Separation Date
Parent Company
Previous License
HERMAC *217NT
Next License
Associated License
Business Owner Information
Name
Role
Effective
Date
Expiration
Date
HERMANSON,
RICHARD L
PARTNER/MEMBER
01/01/1980
ALMON, KEVIN
PARTNER/MEMBER
01/01/1980
MACDONALD, JAMES
PARTNER/MEMBER
01/01/1980
•
Bond Information
Bond
Bond
Company
Name
Bond Account
Number
Effective
Date
Expiration
Date
Cancel
Date
Impaired
Date
Bond
Amount
Received
Date
Page 1 of 2
https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= HERMACL005BJ 05/27/2008
DUCT INSULATION (R-- -VALUE) LAST UPDATED: 01 /17/07
DUCT TYPE
DUCT LOCATION
N -R INSULATION
R -VALUE
RESID. INSULATION
R- -VALUE
REMARKS
SUPPLY, RETURN
NOT WITHIN CONDITIONED SPACE: ON EXTERIOR OF
BUILDING, ON ROOF, IN ATTIC, IN ENCLOSED CEILING
SPACE, IN WALLS, IN GARAGE, IN CRAWL SPACES
R -7
R -8
1,2,3
OUTSIDE AIR INTAKE
WITHIN CONDITIONED SPACE
VARIES
R -8
1,2,4,5
SUPPLY, RETURN, OUTSIDE
AIR INTAKE
NOT WITHIN CONDITIONED SPACE:
IN CONCRETE, IN GROUND
R -5.3
R -5.0
1,2
SUPPLY WITH <55° OR
>105° AIR TEMPERATURE
WITHIN CONDITIONED SPACE
R -3.3
NOT REQ.
1,2
PIPE INSULATION (INCHES) LAST UPDATED: 01/17/07
SERVICE
FLUID
TEMP °F
INSULATION CONDUCTIVITY
NOMINAL PIPE DIAMETER (IN)
CONDUCTIVITY
RANGE
MEAN TEMP
RATING °F
RUN -OUTS
UP TO 2
1 &
LESS
>1 TO
2
>2 TO
4
>4 TO
6
>6
HWS &R
141 -200
0.25 -0.29
125
0.5
1.5
1.5
1.5
1.5
1.5
HWS &R
105-140
0.24 -0.28
100
0.5
1.0
1.0
1.0
1.5
1.5
CHWS &R
40 -45
0.23 -0.27
75
0.5
0.5
0.75
1.0
1.0
1.0
CHWS &R
<40
0.23 -0.27
75
1.0
1.0
1.5
1.5
1.5
1.5
CDWS &R
40 -45
0.23-0.27
75
0.5
0.5
0.75
1.0
1.5
1.0
A
AC
ACH
ACT
AD
ADD'L
AFF
AFG
AHU
ALUM
AMP /AMPS
AP
ARCH
BC
BDD
BF
BHP
BLDG
BOD
BOP
BOT
BS
BTU
BTU H
CAP
CC
CD
CDWR
CDWS
CFM
CHWR
CHWS
CLG
COL
CONC
COND
CONN
CONT
CONTR
COORD
COP
CT
CU
CW
DB
DBA
DDC
DEFL
DEG
DC
DIA
DMPR
DN
DT
DWG
EXH
EA
EAT
EC
EER
EF
EFF
EL
ELEC /ELECT
EP
EMCS
ENT
EQUIP
ESP
EWT
EXIST
F
FAC
ED
FDC
FF
FIC
FIO
FLA
FLEX
FLR
FOB
FOIC
FOS
FOT
FP
FPM
FSD
FT
FUT
FV
G
GA
GALV
GC
GEN
GPM
GR
GRD
GWB
HD
HORIZ
HP
HR
HSPF
HT
HWTG
HWR
HWS
HX
MECHANICAL ABBREVIATIONS
AMPS
AIR CONDITIONING
AIR CHANGES PER HOUR
ACOUSTICAL TILE CEILING
ACCESS DOOR
ADDITIONAL
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
AIR HANDLING UNIT
ALUMINUM
AMPERAGE
ACCESS PANEL
ARCHITECT
BEADED COLLAR
BACKDRAFT DAMPER
BELOW FLOOR
BRAKE HORSEPOWER
BUILDING
BOTTOM OF DUCT
BOTTOM OF PIPE
BOTTOM
BIRD SCREEN
BRITISH THERMAL UNIT
BRITISH THERMAL UNITS PER HOUR
CAPACITY
CONTROLS CONTRACTOR
CEILING DIFFUSER /CONDENSATE DRAIN
CONDENSER WATER RETURN
CONDENSER WATER SUPPLY
CUBIC FEET PER MINUTE
CHILLED WATER RETURN
CHILLED WATER SUPPLY
CEILING
COLUMN
CONCRETE
CONDENSATE
CONNECT /CONNECTED /CONNECTION
CONTINUOUS /CONTINUATION
CONTRACTOR
COORDINATE
COEFFICIENT OF PERFORMANCE
COOLING TOWER
CUBIC /CONDENSER UNIT
DOMESTIC COLD WATER /CONDENSER WATER
DUCTBOARD /DRY BULB
DECIBEL
DIRECT DIGITAL CONTROL
DEFLECTION
DEGREE/ DEGREES
MODULAR DIFFUSER (GWB CEILING)
DIAMETER
DAMPER
DOWN
MODULAR DIFFUSER ( "T -BAR" CEILING)
DRAWING
EXHAUST
EACH
ENTERING AIR TEMPERATURE
EGGCRATE GRILLE /END CAP /ELEC CONTRACTOR
ENERGY EFFICIENT RATING
EXHAUST FAN
EFFICIENCY
ELEVATION
ELECTRICAL /ELECTRIC
END PLUG
ENERGY MANAGEMENT CONTROL SYSTEM
ENTERING
EQUIPMENT
EXTERNAL STATIC PRESSURE
ENTERING WATER TEMPERATURE
EXISTING
FAHRENHEIT
FIRE ALARM CONTRACTOR
FIRE DAMPER
FIRE DEPARTMENT CONNECTION
FINISHED FLOOR
FURNISHED AND INSTALLED BY CONTRACTOR
FURNISHED AND INSTALLED BY OWNER
FULL LOAD AMPS
FLEXIBLE
FLOOR
FLAT ON BOTTOM
FURNISHED BY OTHERS. INSTALLED BY CONTRACTOR
FLAT ON SIDE
FLAT ON TOP
FIRE PROTECTION
FEET PER MINUTE
FIRE /SMOKE DAMPER
FOOT /FEET
FUTURE
FACE VELOCITY
GRILLE
GAUGE /GALLON
GALVANIZED
GENERAL CONTRACTOR
GENERAL
GALLONS PER MINUTE
GRILLE
GRILLE /REGISTER /DIFFUSER
GYPSUM WALL BOARD
HEAD
HORIZONTAL
HORSEPOWER
HOUR
HEATING SEASONAL PERFORMANCE FACTOR
HEIGHT
HIGH WALL TRANSFER GRILLE
HOT WATER RETURN
HOT WATER SUPPLY
HEAT EXCHANGER
HZ
BC
CW
D
E
MC
N
N WG
PLV
KW
HERTZ
NTERNATIONAL BUILDING CODE
NDUSTRIAL COLD WATER
NSIDE DIAMETER /DIMENSION
NVERT ELEVATION
NTERNATIONAL MECHANICAL CODE
NCHES
NCHES WATER GAUGE
NTEGRATED PART LOAD VALUE
KILOWATTS
LAT LEAVING AIR TEMPERATURE
LB /LBS POUND /POUNDS
LD /LIN DIFF LINEAR DIFFUSER
LF /LIN FT LINEAL FOOT /FEET
LPG LIQUID PROPANE GAS
LVG LEAVING
LWA SOUND POWER
LWG LOW WALL GRILLE
LWR LOW WALL REGISTER
LWT LEAVING: WATER TEMPERATURE
MAX MAXIMUM
MAU MAKE UP. AIR UNIT
MBH 1000 'BRITISH THERMAL UNITS
MCA MINIM Up CIRCUIT AMPACITY
MD MOTORED DAMPER
MFR MANUFACTURER
MISC MISCELLANEOUS
MIN MINIMUM /MINUTE
MT MOUNT
MTD MOUNTED
MUW MAKE -UP WATER
N/A NOT APPLICABLE
NC NORMALLY CLOSED /NOISE CRITERIA
NG /NGAS NATURAL GAS
NIC NOT IN CONTRACT
NO NORMALLY OPEN /NUMBER
NPW NON- POTABLE WATER
N -R NON-RESIDENTIAL
OA /OSA OUTSIDE AIR
OB OPPOSED BLADE
OBD OPPOSED BLADE DAMPER
OD OUTSIDE DIAMETER /DIMENSION
P PUMP
PCF POUNDS PER CUBIC FOOT
PD PRESSURE DROP
PH PHASE
POC POINT OF CONNECTION
PRESS PRESSURE
PSI POUNDS PER SQUARE INCH
PSIG POUNDS PER SQUARE INCH GAUGE
QTY QUANITY
R RETURN GRILLE /RELOCATED /RETURN
RA RETURN AIR
RD /RND ROUND
REF REFERENCE
REG REGISTER
REQ REQUIRED
RESID RESIDENTIAL
RF RELIEF
RG RETURN GRILLE
RL REFRIGERANT LIQUID
RPM REVOLUTIONS PER MINUTE
RS REFRIGERANT SUCTION
S SUPPLY
SA SUPPLY AIR
SAT SATURATION
SD SMOKE DETECTOR
S/D SLIP & DRIVE CONNECTION
SEER SEASONAL ENERGY EFFICIENCY RATING
SENS SENSIBLE
SG SUPPLY GRILLE
SL SOUND LINED
SM SPIRALMATE /SHEETMETAL
SPEC SPECIFICATION
SO SCREENED OPENING
SOG SLAB ON GRADE
SP STATIC PRESSURE
SQ FT SQUARE FEET
SR SIDE WALL REGISTER
SS STAINLESS STEEL
STRUC STRUCTURAL
T TRANSFER
TA TRANSFER AIR
TEMP TEMPERATURE /TEMPORARY
TBD TO BE DETERMINED
TG TRANSFER GRILLE
TOC TOP OF CONCRETE /CURB
TOD TOP OF DUCT
TOS TOP OF STEEL /TOP OF SLAB
TOT TOTAL
TSP TOTAL STATIC PRESSURE
TSTAT THERMOSTAT
TYP TYPICAL
UH UNIT HEATER
UNO UNLESS NOTED OTHERWISE
V VOLT .
VIAQC VEIJT..AND INDOOR AIR QUALITY CODE
VD VOLUME DAMPER
VEL VELOCITY
VERT VERTICAL
VFD VARIABLE FREQUENCY DRIVE
VOL VOLUME
W WALL /WALLS, WRAPPED DUCT
WB WET BULB
WG WATER GAUGE
W/ WITH
W/0 WITHOUT
W /SF WATTS PER SQUARE FOOT
WSEC WASHINGTON STATE ENERGY CODE
MECHANICAL LEGEND
10x10
10x
i10xlo ;;X,
: 10x10
1 10x10
: 10x10 Ei
J - 1 Ox 1 0 ;,/1
1Ox
•
1 00
1 0 I
DUCT OVERLAP
t 100 T_
45° TAP
10 VOLUME DAMPER
»:iE
,rwvv vv
MOM
. t16x16SL
� 16x16DB
z
• CHWS
• CHWR
9
CD1 -100
80
SP
k
k �I
C�1
t="j‘rv%tT
0
CD 40
CHWS
CHWR
2- RL 5
.- Rs -5
2 NG -5
CDWS CDWS -5
• CDWR CDWR -5
z ----�- Hws 1
2- HWR S
2- COND COND -5
RECTANGULAR SUPPLY AIR DUCT -
TURNING UP OR TOWARD
RECTANGULAR SUPPLY AIR DUCT -
TURNING DOWN OR AWAY
RECTANGULAR EXHAUST OR RETURN AIR
DUCT - TURNING UP OR TOWARD
RECTANGULAR EXHAUST OR RETURN AIR
DUCT - TURNING DOWN OR AWAY
ROUND DUCT -
ROUND DUCT -
FLATOVAL DUCT
FLATOVAL DUCT
BOOT TAP
CHANGE OF ELEVATION RISE(R) DROP(D)
TRANSITION
TURNING VANES /SPUTTERS
DUCT MOUNTED SMOKE DETECTOR
BACK DRAFT DAMPER
FLEXIBLE DUCT
AIR FLOW DIRECTION FORCED AIR)
AIR FLOW DIRECTION DRAWN AIR)
MOTOR OPERATED DAMPER
FLEX CONNECTION
SMOKE DAMPER
FIRE DAMPER
COMBINATION FIRE & SMOKE DAMPER
SOUND TRAP
ACCESS DOORS
TURNING UP OR TOWARD
TURNING DOWN OR AWAY
- TURNING UP OR TOWARD
- TURNING DOWN OR AWAY
ACOUSTICALLY LINED DUCT (SOUND LINED)
DUCT BOARD
FABRIC DUCT
VAV BOX
CEILING SUPPLY AIR DIFFUSER (SHOWN
WITH REDIRECTED AIR CORE)
CEILING RETURN, TRANSFER OR
EXHAUST AIR GRILLE
SLOTTED DIFFUSER (PLAN VIEW)
REVISION CLOUD & TRIANGLE
ROUND DUCT SYMBOL
FLATOVAL DUCT SYMBOL
DEGREES SYMBOL
POINT OF CONNECTION
GRD TAG IDENTIFIER = TYPE -CFM
SIZE
THERMOSTAT /TEMPERATURE SENSOR
HUMIDITY SENSOR
SMOKE DETECTOR
STATIC PRESSURE SENSOR
EXISTING DUCTWORK
DEMO DUCTWORK
WALL - MOUNTED GRILLE
o PIPE ELBOW UP
PIPE ELBOW DN
DIRECTION OF FLOW
DIRECTION OF SLOPE
PLUG OR CAP
GAS PRESSURE REDUCING ASSEMBLY
SOLENOID VALVE
PUMP
CHILLED WATER SUPPLY
CHILLED WATER RETURN
REFRIGERANT LIQUID
REFRIGERANT SUCTION
NATURAL GAS
LIQUID PROPANE GAS
CONDENSER WATER SUPPLY
CONDENSER WATER RETURN
HEATING WATER SUPPLY
HEATING WATER RETURN
CONDENSATE
DOWN
MECHANICAL GENERAL NOTES
1. ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO
THE 2006 IBC, 2006 WSEC, 2006 IMC & 2006 WSVIAQC.
2. DIMENSIONS ARE TO FACE OF STUD, CONCRETE, OR MASONRY UNLESS NOTED OTHERWISE.
3. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN.
4. VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, DETAILS, ETC. NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR
TO PROCEEDING WITH THE WORK.
5. WHEN CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, DETAILS SHALL BE THE SAME
AS FOR OTHER SIMILAR WORK. IF ADDITIONAL QUESTIONS REMAIN, CONTACT THE ENGINEER PRIOR TO PROCEEDING.
6. ALL STRUCTURAL OPENINGS AND PLATFORMS SHALL BE PROVIDED BY THE GENERAL CONTRACTOR UNLESS NOTED OTHERWISE.
7. DUCT SEALING AND CONSTRUCTION TO MEET SMACNA AND ENERGY CODE REQUIREMENTS. UNLESS OTHERWISE NOTED,
LOW PRESSURE DUCTWORK (DOWNSTREAM OF VAV BOXES, CONSTANT VOLUME AC SYSTEMS, TOILET EXHAUSTS, ETC.)
TO MEET 2" CONSTRUCTION STANDARDS WITH SEAL CLASS C. MEDIUM PRESSURE DUCTWORK (UPSTREAM OF VAV BOXES,
HIGH VELOCITY EXHAUSTS, ETC.) TO MEET 4" CONSTRUCTION STANDARDS WITH SEAL CLASS A. DUCT RISERS IN SHAFTS
WITH DAMPERED PENETRATIONS TO MEET 6" CONSTRUCTION STANDARDS WITH SEAL CLASS A.
8. ALL CEILING DIFFUSERS ARE 4 -WAY THROW UNLESS NOTED OTHERWISE.
9. ALL DUCT DIMENSIONS ARE CLEAR INSIDE DIMENSIONS AFTER LINING HAS BEEN INSTALLED.
10. OUTSIDE AIR INTAKES ON ALL AIR HANDLING UNITS SHALL BE 10 FEET AWAY FROM ANY FUEL BURNING EQUIPMENT, AND 10 FEET
AWAY FROM, OR 3 FEET BELOW ANY PLUMBING VENT OR EXHAUST OUTLET.
11. ALL AIR ECONIMIZERS SHALL BE CAPABLE OR THE FOLLOWING: .
- 0% TO 100% OF THE DESIGN SUPPLY AIR
- CONTROLLED BY A CONTROL SYSTEM DETERMINING IF THE OUTSIDE AIR CAN MEET PART OR ALL OF THE BUILDING COOLING LOADS.
- INTEGRATED TO PROVIDE PARTIAL COOLING EVEN WHEN MECHANICAL COOLING IS REQUIRED.
12. OUTSIDE AIR INTAKE, RELIEF, AND EXHAUST OPENINGS SHALL BE EQUIPPED WITH MOTORIZED OR GRAVITY DAMPERS WHICH CLOSE
AUTOMATICALLY WHEN SYSTEM IS OFF OR UPON POWER FAILURE, AS REQUIRED BY ENERGY CODE.
13. THE CONTROL SYSTEM SHALL BE 7-DAY PROGRAMABLE, CAPABLE OF BEING SET FOR SEVEN (7) DIFFERENT DAY TYPES PER WEEK,
AND CAPABLE OF A DEADBAND SETTING OF AT LEAST 5 DEGREES F 10 °F FOR RESIDENTIAL) BETWEEN THE HEATING AND COOLING
SETPOINTS. AHU CONTROL SYSTEM SHALL INCLUDE A MICROPROCESSOR AND BE CAPABLE OF RESETTING SUPPLY AIR TEMPERATURES
BY REPRESENTATIVE BUILDING LOADS.
14. RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE
OF SYSTEM ACCEPTANCE PER THE WASHINGTON STATE ENERGY CODE. AN OPERATING MANUAL AND MAINTENANCE MANUAL
SHALL BE PROVIDED TO THE BUILDING OWNER. ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCING REPORT
SHALL BE PROVIDED TO THE OWNER. HVAC CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORDANCE
WITH SPECIFICATIONS AND APPROVED PLANS. A PRELIMINARY COMMISIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL
BE PREPARED PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY. A COMPLETE FINAL COMMISSIONING REPORT OF
TEST PROCEDURES AND RESULTS SHALL BE PROVIDED TO THE OWNER. COMMISIONING, SYSTEM BALANCING, RECORD DRAWINGS
AS REQUIRED PER THE WASHINGTON STATE ENERGY CODE.
15. MECHANICAL SYSTEMS SHALL COMPLY WITH SEISMIC RESTRAINT REQUIREMENTS OF THE BUILDING CODE, SMACNA AND ASCE 7.
ALL LIFE SAFETY HAZARDOUS MATERIAL RELATED SYSTEMS SHALL BE DEEMED AN I10=1.5 FOR RESTRAINT METHODS OR AS NOTED
ON THE DRAWINGS. REFER TO THE ABOVE NOTED CODES FOR INSTALLATION REQUIREMENTS AND EXCEPTIONS BASED ON SIZING,
WEIGHTS AND MOUNTING HEIGHTS.
16. PROVIDE EARTHQUAKE RESTRAINTS FOR HVAC EQUIPMENT AS REQUIRED BY SMACNA SEISMIC RESTRAINT MANUAL, SEIZMIC HAZARD B.
WIRES FOR CEILING SYSTEM ETC. SHALL NOT BE HUNG OFF HVAC EQUIPMENT OR HVAC EQUIPMENT SUPPORTS.
17. PROVIDE FIRE AND COMBINATION FIRE /SMOKE DAMPERS WHERE SHOWN ON PLANS AND WHERE REQUIRED PER CODE.
18. ALL PIPING PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE SEALED WITH AN UL APPROVED FIRE CAULKING.
19. SMOKE DETECTORS PROVIDING AUTOMATIC SHUTDOWN SHALL BE PROVIDED FOR HVAC EQUIPMENT DELIVERING IN EXCESS OF
2000 CFM [INCLUDING MULTIPLE UNITS DUCTED INTO COMMON DISTRIBUTION OR RETURN, WITH AN AGGREGATE SUPPLY GREATER
THAN 2000 CFM1 OR EACH STORY OF RETURN SYSTEMS OVER 15.000 CFM IN A MULTI -STORY INSTALLATION, PER CODE.
SMOKE DETECTORS SHALL BE FURNISHED AND NSTALLED BY ELECTRICAL CONTRACTOR UNLESS NOTED OTHERWISE. POWER- WIRING
AND INTERLOCK TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR AS APPLICABLE.
20. ACCESS PANELS SHALL BE PROVIDED BY MECHANICAL CONTRACTOR AND INSTALLED BY GENERAL CONTRACTOR.
21. ALL MOTOR STARTERS NOT SHOWN IN EQUIPMENT SCHEDULES SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR.
22: FOR ALL "SEALED AIR TIGHT" SHAFTS OR ROOMS, THE FOLLOWING SHALL OCCUR:
-ALL VERTICAL JOINTS INSIDE THE SHAFT SHALL BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT,
INCLUDING THE SHAFT CORNERS (BY GC)
- TOP AND BOTTOM WALL TRACKS SHOULD BE CAULKED ALONG THEIR ENTIRE LENGTH (BY GC)
- ANY FLOOR DECKING PERPENDICULAR TO THE SHAFT SHALL BE CAULKED (BY GC). FILLING WITH ROCK WOOL IS NOT ACCEPTABLE
- ANY PENETRATIONS OF THE SHAFT CONSTRUCTION (DUCTWORK, CONDUIT, PIPING, ...) SHALL BE SEALED ON BOTH SIDES
OF THE PENETRATION.
- USE SECTION 905 OF THE 2003 IBC FOR MAXIMUM ALLOWABLE LEAKAGE AREA, FOLLOWING THE GUIDELINES FOR TIGHT STAIR
SHAFT CONSTRUCTION.
-ALL DOORS SHALL BE PROVIDED WITH TIGHT FITTING GASKETS, AND OPEN AGAINST THE DIRECTION OF ROOM /SHAFT PRESSURE.
23. MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL BE 12 FEET. REFER TO INSTALLATION DETAILS FOR SUPPORT REQUIREMENTS.
FLEXIBLE DUCT FLAME SPREAD RATING SHALL BE < 25 AND SMOKE DEVELOPED RATING SHALL BE < 50. USE FLEXIDUCT
MODEL G -KM FOR LOW AND MEDIUM PRESSURE APPLICATIONS OR APPROVED EQUAL. INSULATE DUCT PER NOTE 11 ABOVE.
24. LOCATION AND DETAILS OF EQUIPMENT, DUCT ROUTING, AND CONNECTIONS ARE APPROXIMATE. COORDINATE FINAL LOCATIONS WITH
OTHER TRADES. INSTALL IN ACCORDANCE WITH APPROVED SUBMITTALS AND DETAIL DRAWINGS WHEN APPLICABLE.
25. FOR RESIDENTIAL INSULATION ON DUCTWORK AND PIPING SEE ENERGY CODE CHAPTER 5 AND TABLES 5 -11 AND 5 -12.
1. REFER TO ENERGY CODE SECTION 1414.2 FOR FURTHER REQUIREMENTS
2. REQUIREMENTS APPLY TO HEATED AND MECHANICALLY COOLED DUCT SYSTEMS AS NOTED. INSULATED COOLED
DUCTS REQUIRED A VAPOR RETARDER (PERM < 0.5 ) AND SEALED JOINTS.
3. WEATHERPROOF BARRIER REQUIRED AROUND DUCTWORK TO MAINTAIN WATER TIGHTNESS.
4. INSULATE OUTSIDE AIR DUCTS TO BUILDING ENVELOPE LEVEL PER ENERGY CODE CHAPTER 13 UNTIL
CONNECTED TO EQUIPMENT SERVED OR TO THE CODE REQUIRED SHUTOFF DAMPER (THEN R -7 FOR REST Of
INSTALLATION ).
5. R -7 CAN BE USED IN LIEU OF BUILDING ENVELOPE INSULATION LEVEL IF: DEDICATED OUTSIDE AIR SYSTEM
AND LESS THAN 2,800 CFM.
-S
CONDENSER WATER (FOR NON-ECONOMIZER SYSTEMS - INSULATION IS NOT REQUIRED)
DRAWING INDEX
SHEET NO.
P -A -01
P -E -11
P - I - 01
SHEET TITLE
LEGEND, ABBREVIATIONS, GENERAL NOTES, & SHEET INDEX - PLUMBING
FIRST FLOOR PLAN - PLUMBING
SCHEDULES SHEET - PLUMBING
APN NUMBER
1023049069
LEGAL DESCRIPTION
PORTION OF GOV LOT 15 IN SW 1/4 OF SECTION 10 -23 -04 BEGIN
NW CORNER OF SW 1/4 TH S 01 -46 -02 W 107,22 FT TH S
87 -33 -12 E 512.24 FT TO POINT OF BEGINNING TH S 87 -33 -12 E
214.16 FT TH N 78 -40 -52 E 415.05 FT TO WLY MARGIN OF E
MARGINAL WAY TH S 16 -31 -41 E 241.92 FT TH S 28 -02 -57 E
104.42 FT TH S 17 -01 -47 E 100.50 FT TH S 11 -19 -15 E 13.28
FT TH N 58-13-58 W 473,87 FT TH S 01 -46 -02 W 37 FT TH N
8a:--13-58 W 307.80 FT TH N 01 -46 -02 E 373.93 FT TO POINT OF
BEGINNING - LOT 1 OF CITY OF TUKWILA BOUNDARY LINE ADJUSTMENT
NO,L2000 -042 RECORDING NO 20000828900001
'. ;s;
1
VICINITY MAP
NO SCALE
SITE MAP
NO SCALE
FILE COPY
Permit No.
City of Tukwila
BUILDING DIVISION
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan rev2w fe=es
Plar review approval Is subject to errors and omissions.
Approval of construction documents does not authorize
the violation of any = t � � • v • e or ordinance. Receipt
of approv= i 3Id Cop • .con l , . . r` is aura ► : ed�:ed:
By i.4.21■
_'<-2-77,* 0-11 -��
Date:
' - 1 EWEWED ®R
DE COMPLIANCE
AP ROVE'
MAY 2 2 2008
tv of T
SEPARATE PERMIT
REQUIRED FOR:
v/
Mechanical
[Electrical
❑ Plumbing
❑ Gas Piping
City of Tukwila
I BUILDING DIVISION
i
RECEIVED
CITY OF TUKWILA
MAY 15 2008
PERMIT CENTER
Hermanson
Micioso ft
TUKWILA
2
BUILDING
CD SET
3433 SOUTH 120TH PL
TUKWILA, WA 98168
Design
Drawn
Checked
Date
HERMANSON Project No.
M.S. Project No.
No. Date
Hermanson Company LLP
1221 2nd Avenue North
Kent, Washington 98032
Tel: (206) 575 -9700
Fax: (206) 575 -9800
www.hermanson.com
Contractor Reg #: HERMACLOO5BJ
Design Team
Revisions
Description
5/14/2008 CD SET
Registration
EXPIRES 1/29/ 1
Key Plan
Bar Code
Sheet Title /Number
P-A-01
MG
ER
DN
5/14/2008
11-8-0286
P.11170
LEGEND,
ABBREVIATIONS,
GENERAL NOTES, &
SHEET INDEX - PLUMBING
4 II
= L
4
(
SCALE: 1/8" =
FIRST FLOOR PLAN - PLUMBING
_ 1
il II II 11
11
p ssizaziN es itima le4se• p 0.344,L
REVIEWED FOR \
70E COMPLIANCE
APPROVED
MAY 2 2, 20q8
Citv Of Tukw
BUILDINciDlyl..c.:-103_1_ _
C140F41
MAY "I 5 2008
PERMIT CENTER
Design
Drawn
Checked
Date
M.S. Project No.
No. Date
Hermanson
Hermanson Company LLP
1221 2nd Avenue North
Kent Washington 98032
Tei: (206) 575-9700
Fax: (206) 575-9800
www. hermanson. corn
Contractor Reg #: HERMACL005BJ
TUKWILA
2
BUILDING
CD SET
3433 SOUTH 120TH PL
TUKWILA, WA 98168
HERMANSON Project No.
Design Team
Revisions
Description
5/14/2008 CD SET
Registration
I EXPIRES 1 /29/ I
J
Key Plan
Bar Code
Sheet Title/Number
FIRST FLOOR
PLAN
-PLUMBING
P-E-11
MG
ER
ON
5/14/2008
11-8-0286
P.11170
• '...••• -
PLUMBING FIXTURE SCHEDULE LAST UPDATED 5/14/08
SYMBOL
DESCRIPTION
MANUFACTURER AND MODEL NUMBER
HW
CW
W
V
REMARKS
LAV -1
LAVATORY
MATCH EXISTING
1/2"
1/2"
2"
1 -1/2"
2
SH -1
SHOWER
MATCH EXISTING
1/2"
1/2"
2"
1 -1/2"
2
WC-1
WATER CLOSET
MATCH EXISTING
-
1 "*
4"
2"
2
U -1
URINAL
MATCH EXISTING
-
3/4"
2"
1 -1/2"
2
NOTES:
SIZE CW AT 1 1/4" DOWN TO FIXTURE CONNECTION FOR ALL FLUSH VALVE WATER CLOSETS
1 PROVIDE JUST J -35 SS CUP STRAINER WITH REMOVABLE BASKET, 1 1/2 17 GA P -TRAP CHROME PLATE, BRASSCRAFT LOOSE -KEY LAV SUPPLY KIT
CHROME PLATED WITH BRAIDED FLEXIBLE HOSE.
2 WATER SERVICE & SHUT OFF BY PLUMBING CONTRACTOR
3 DISHWASHER PROVIDED BY OTHERS. CONNECT DRAIN TO SINK TAILPIECE WITH DRAIN AND WATER SERVICE & SHUT OFF BY PLUMBING CONTRACTOR. AT SINK
PROVIDE WITH EASTMAN AIRGAP FITTING
4 POLYSTYRENE OR METAL BOX WITH QUARTER TURN STOP SHUTOFF.
(nHr3
C fi }DE COMPLxp
APPROV f.,..
�, � ? k1
MAY 2 J�
play
'�. 'zy
tv, 1r-
RECEIVED
CITY OF TUKWILA
MAY 15 2008
PERMIT CENTER
Hermanson
3433 SOUTH 120TH PL
TUKWILA, WA 98168
Design
Drawn
Checked
Dote
HERMANSON Project No.
M.S. Project No.
No.
Date
Hermanson Company LLP
1221 2nd Avenue North
Kent, Washington 98032
Tel: (206) 575 -9700
Fax: (206) 575 -9800
www.hermanson.com
Contractor Reg #: HERMACL005BJ
TUKWILA
2
BUILDING
CD SET
Design Team
Revisions
Description
5/14/2008 CD SET
Registration
I EXPIRES 1/29/ I°
1
5/14/2008
1 1 -8 -0286
P.11170
Key Plan
Bar Code
Sheet Title /Number
SCHEDULES
SHEET
- PLUMBING
P-.I-o1
MG
ER
DN